1 Page 1 of 11 For: Retail Motor Fuel Dispenser (RMFD) Dispenser, Electronic Computing Models: NA, NPA, NPB, NPC and Field Upgrade Modules Gilbarco Part Number ENC-DEF-RF Generic Names: Encore 500, Encore 500S and Encore 700S Total Sale Capacity: $ Total Volume Capacity: Maximum Unit Price Capacity: $9.999 *Submitted By: Contact Info. Updated October 2018 Gilbarco Inc. 700 West Friendly Avenue Greensboro, NC 2710 Tel: (6) Fax: (6) Contact: Brent K. Price brent.price@gilbarco.com Website: Standard Features and Options Standard Features: Back-lighted Liquid Crystal Displays (LCD) Display Back-up Stand-alone or Console Controlled Nozzles Lane-oriented and High-hose Attachment Downloadable Software Category 1 Device (see sealing) All Units Have the Electronic Totalizer with Volume and Sales up to Units Options: Lever-activated Nozzle Key Control Cash/Credit Programmable Pump Preset Cash/Credit Preset Cash and/or Credit Cash Acceptor Card Reader in Dispenser (CRIND) 10." LCD Display Info Screen Transmitter/Receiver in Dispenser (TRIND) Intercom/Overhead Speaker Bar Code Scanner Full Vapor Recovery Balance (booted) Vapor Recovery Ready "VaporVac" 5.7" Monochrome Display Brand Lighting / Light Conduit 10." Touch-Screen 10." Color Soft Key Display Encrypted Card Reader Encrypted PIN Pad Push-to-Start (activates pump if nozzle is lifted) Units with Coriolis Meter Used with Diesel Exhaust Fluid (DEF) Meter Model Numbers Used in Dispenser Endress & Hauser LPG Mass DN15 Diesel Exhaust Fluid (DEF) P9XXX Ultra Hi-Diesel Name Coriolis Meter LC M5 Series Minimum Flow Rate 1.0 GPM 12 GPM Maximum Flow Rate 10 GPM 60 GPM NOTICE / WARNING: DEF is a mixture of urea and water and is used to reduce diesel exhaust emissions. DEF is not an engine fuel. DEF must not be mixed with diesel fuel or engine damage will occur. Volumetric accuracy should be verified using a stainless steel prover and this prover only used to test DEF to prevent contamination of engine fuels. This device was evaluated under the National Type Evaluation Program and was found to comply with the applicable technical requirements of "NIST Handbook : Specifications, Tolerances and Other Technical Requirements for Weighing and Measuring Devices." Evaluation results and device characteristics necessary for inspection and use in commerce are on the following pages. James Cassidy Chairman, NCWM, Inc. 115 M Street, Suite 110 / Lincoln, Nebraska Kristin Macey Chairman, National Type Evaluation Program Committee Issued: February 5, 2018 The National Conference on Weights and Measures (NCWM) does not approve, recommend or endorse any proprietary product or material, either as a single item or as a class or group. Results shall not be used in advertising or sales promotion to indicate explicit or implicit endorsement of the product or material by the NCWM.
2 Page 2 of 11 Model Designation: The specific characters in the model designation are represented below: Position 1 Position 2 and Hydraulics Description Grade / Hose Not Part of Model Code N = Encore A MPD Dispenser 1 Grade UREA Only A = Multi-house PA Ultra-high Master 2 Grade, Diesel and DEF P = High Flow PB Ultra-high Master/Satellite Combo 2 Grade, Diesel and DEF P = High Flow PC Ultra-high Master 2 - Grade diesel plus DEF, Single Sided P = High Flow Application: Encore Model NA is used to dispense Diesel Exhaust Fluid (DEF). Encore Models NPA, NPB and NPC are used to dispense diesel fuel from one hose and DEF from the other hose. Models NA, NPA, NPB and NPC are shipped from from Gilbarco as a complete dispenser. Gilbarco Model "ENC DEF RF" is a DEF upgrade kit consisting of the referenced DEF module shown in the attached photographs. These retrofit kits are intended to be added (field installed) to the manufactures Encore series fuel dispensers. One or two DEF kits may be added to any Gilbarco Encore model approved in CoC DEF is a mixture of urea and water and is used to reduce diesel exhaust emissions. DEF is not an engine fuel. DEF must not be mixed with diesel fuel or engine damage will occur. Volumetric accuracy should be verified using a stainless-steel prover and this prover only used to test DEF to prevent contamination of engine fuels. Identification: The identification badge, a self-destructive badge is located behind the locked main door. Optional features are indicated on the identification plate. A self-destructive identification badge for the DEF field upgrade module is on the DEF module beside the DEF Nozzle boot. A supplemental label is provided to update the original dispenser s model number when the DEF field upgrade kit is added. Sealing: The Encore Series device has no remote configuration capability and is classified as a Category 1 device. Access to all metrological features and functions are controlled through the use of a sealable security switch. The security switch has two positions, "normal/sealed" and "calibration/configuration." When the security switch is in the "calibration/configuration" position, sealable parameters including meter calibration, gallon/liter settings, and blend ratio settings can be accessed. Access to sealable parameters is prevented by placing the security switch in the "normal/sealed" position and threading a wire security seal through the cover, which fits over the security switch. The wire security seal must be broken in order to lift the hinged cover and to move the security switch to the "calibration/configuration" position. The security switch and Manager's keypad are located behind the locked main options door. Access to the security switch and Manager's keypad requires opening the options door. This seal is also used to calibrate the Coriolis meter. The Coriolis meter located in the side column of the dispenser is additional provided with a sealing means. The meter consists of 2 main components with matching serial numbers, the sealed (welded) measuring chamber and the electronics module. The Electronics module has 2 access covers; the smaller cover is used to access power and date wiring and is not provided with a sealing means. The larger cover is used to access metrological aspects of the meter and is provided with a sealing means. The seal on this larger cover must be broken, the cover removed, an internal cover removed and internal wiring disconnected in order to remove the electronics module from the measuring chamber. Encore "S" series may also have a user provided lock that must be accessed. The locked lower hydraulics door must be removed to access the user provided lock. This locks a "tool box" type latch that secures the main door. To access features located behind the main door first remove the lower hydraulics door, then unlatch the main door's "tool box" latch, then open the main door. The main door is secured with a lock / key and the lock is located on the left side of the door. The Manager's keypad is secured to a metal "Vault" that prevents access to the keypad without opening the main door. These changes are required to deter unauthorized assess to the unit that may result in undetected fraudulent activities. Electronic Calibration (E-cal): Access to the electronic calibration feature is through the security switch described above. With the switch in the "calibration/configuration" position, a calibration code and the volume of the volumetric standard are entered into the keypad next to the security switch. Product is then dispensed into the standard, a delivery error is determined in cubic inches, and the error value is entered into the keypad. The security switch is then returned to the normal operating ("normal/sealed") position and the switch cover is sealed with a wire security seal. Sealing Continued: Gallon/Liter Setting: Access to the gallon/liter setting is through the security switch described above. With the switch in the "calibration/configuration" position, a conversion factor is used to program all Encore Series dispensers to indicate in gallons or liters. Gallon/Liter setting information can also be viewed without entering the configuration mode. With the switch in the
3 Page of 11 "normal/sealed" position, the number of times that the conversion factor has been changed since the initial installation can be displayed in the main "Volume" display by pressing "ENTER" on the manager's keypad. Press any other key to revert to the normal display. See "examples" shown below. Operation: Units equipped with the Endress & Hauser LPGmassDN15 Coriolis meter are approved to dispenser Diesel Exhaust Fluid (DEF). DEF is a mixture of urea and water and is used to reduce diesel exhaust emissions. DEF is not an engine fuel. DEF must not be mixed with diesel fuel or engine damage will occur. Volumetric accuracy should be verified using a stainless-steel prover and this prover only used to test DEF to prevent contamination of engine fuels. This Coriolis meter is located in the side column and is provided with a sealing means. Calibration of the meter is through the use of the Gilbarco calibration switch. Examples: MPD (Non-Blender) Information is Displayed in the Following Format: Sale Display: XXXX Blank Volume Display: XXXX Number of times volume units (Gallon Liter) have been adjusted. Example 0019 would indicate that the volume unit has been changed a total of 18 times. PPU Grade Display: XXX Blank For units with electronic totalizers (effective April 1, 1998), you can retrieve totals electronically at the pump or dispenser by using the modular keypad. This keypad sits behind the locked access door on the "A" side of the electronics module. For the Encore Series, it mounts on a removable magnetic pad that attaches to the inside cabinet behind the left or right option door. Modular Keypad 1 2 F1 5 6 F $ TOTAL PRESS Vol Total for electronic totals PRESS CLEAR to EXIT CLEAR 0 ENTER VOL TOTAL PRESS ENTER for AUDIT TRAILS Examples Continued: The VOL TOTAL key is used to retrieve volume totals for each fuel grade. These key functions do not require a security code to access. Just press the VOL TOTAL button. The CLEAR key is used to exit volume total or audit trail modes.
4 Page of 11 Retrieving VOL TOTAL Examples: 1. Press "VOL TOTAL" - display changes from normal to volume totals 2. Press "Enter" to change the flashing display location to the first digit. Press "1" for side one or "2" for side two. Press "Enter" - flashing display moves to the second digit 5. Press 1 or 2 or or or 5 or 6, etc., for grades 6. Read electronic totalizer for each side and grade 7. Press "Clear" to return to normal mode The sample below shows a volume total of gallons on side 1, product. Electronic totalizer can display up to units (gallons or liters).
5 Page 5 of 11 Examples Continued: The Encore is provided with a means to change the multiple meters calibration with one sealable means. As a result, HB regulations were changed to require that a means be provided to determine which meter was calibrated. Gilbarco provides a method to determine the number of days, number of times, and number of pulses per gallon/liter for each meter on units manufactured after 1/1/05. Using the manager's keypad press the "Enter" button. The first time the Enter key is pressed the display changes as shown below. The following are depictions of a "blender audit trail" The for a MPD (Non blender) are not depicted will follow the format noted in table on page 8.
6 Page 6 of 11 Examples Continued: Software after v , contain audit trail and supplemental information summarized in the following table. (supplemental information may change at discretion of Gilbarco) # of times ENTER is pressed 1 2 Non-Blender (Unit Type 1-7) Days since the meter has been calibrated* # of times meter has been calibrated Pulses per volume unit for meter Pulses per volume unit for meter Blender (Unit Types 8-9 and 12-19) Blend Ratios Days since the meter has been calibrated* # of times meter has been calibrated Pulses per volume unit for meter * 8888 in the PPU display indicates that meter has not been calibrated outside of the factory Unit Type (supplemental information) UNIT CODE UNIT TYPE 1 GRADE 1 HOSE MPD 2 GRADE 2 HOSE MPD GRADE HOSE MPD GRADE HOSE MPD 2 GRADE, 1 HOSE MPD GRADE, 1 HOSE MPD GRADE, 1 HOSE + 1 MPD GRADE, HOSE BLENDER GRADE, HOSE BLENDR GRADE, 1 HOSE BLENDER GRADE, 1 HOSE BLENDER GRADE, 1 HOSE BLENDER 5 GRADE, 1 HOSE BLENDER 2 GRADE, 1 HOSE BLENDER + 1 GRADE, 1 HOSE BLENDER + 1 GRADE, 1 HOSE BLENDER GRADE, 1 HOSE BLENDER + 1 5
7 Page 7 of 11 Examples Continued: Pressing the enter key a second time, the display show the number of days (Blender audit trail). press Enter 2nd time P indicates audit trail mode $ Vol. P 1 0 Counts blend change mode Configuration changes Gallon or liter 1 62 Number of days since last calibration - 7 information after software version contains supplemental information. press Enter 2nd time (With ) $ Vol. 1 7 Indicates Series - = = 500S Indicates Unit Type Number of days since last calibration - audit trial 8
8 Page 8 of 11 Examples Continued: Pressing the enter key the third time indicated the number of calibrations per meter (Blender audit trail). press Enter rd time P indicates audit trail mode $ Vol. P 1 0 Counts blend change mode Configuration changes Gallon or liter Number of calibrations per meter- audit trail 9 information after software version contains supplemental information. press Enter rd time - (With ) $ Vol. 1 7 Indicates Series - = = 500S Indicates Unit Type 1-19 Number of calibrations per meter audit trail 10
9 Page 9 of 11 Examples Continued: Pressing the enter key a fourth time, the display indicated the number of pulses per gallon or liter (Blender audit trail). press Enter th time P indicates audit trail mode $ Vol. P 1 0 Counts blend change mode Configuration changes Gallon or liter Number of pulses per gallon or liter audit trail information after software version contains supplemental information. press Enter th time (With ) 11 $ Vol. 1 7 Indicates Series - = = 500S Indicates Unit Type Number of pulses per gallon or liter audit trail Press the "Clear" key returns the display to the normal mode. Note that the display will return to the Normal mode if a key in not pressed within 5 seconds. 12
10 Page 10 of 11 Test Conditions: This certificate supersedes Certificate of Conformance No A2 and is issued to expand the scope of models that the DEF retrofit kits may be installed. The market for DEF has expanded and the need to provide DEF for diesel automobiles light duty diesel trucks is growing. Model ENC-DEF-RF DEF retrofit kit may be installed on any Gilbarco Encore series model noted in CoC Up to 2 of these kits may be installed providing DEF to both sides of the dispenser. No additional testing was deemed necessary as all components in the ENC-DEF-RF DEF retrofit kit have been previously tested. Previous test conditions are listed below for reference. Certificate of Conformance Number 09-06A2: This certificate supersedes Certificate of Conformance No A1 and is issued noting the addition of a new Gilbarco Encore diesel with DEF dispenser model NPC. Model NPC is a Gilbarco Ultra Hi 2- product (diesel), single sided unit (NP6) with the DEF module (Model ENC-DEF-RF) added. Model NP6 is approved under NTEP CC A21. The DEF module ENC-DEF-RF is approved under NTEP CC 09-06A1. The DEF module may be added as a field upgrade kit to Gilbarco Model NP6 dispensers. Removes Encore 00S from model family, adds Encore 700S to model family (based on NTEP CC A21). No additional testing was deemed necessary as all components in the new model (NPC) have been previously tested. Certificate of Conformance Number 09-06A1: This certificate supersedes Certificate of Conformance number and is issued noting the addition of a new Gilbarco DEF field upgrade kit. This kit will allow customers with Gilbarco Encore Ultra-Hi series diesel dispensers (Models NP or NP) to add a Gilbarco DEF module model ENC-DEF-RF to existing Gilbarco Encore Ultra Hi diesel dispensers. This DEF module was previously evaluated under NTEP CC The DEF module with all components may be added to Gilbarco Encore models: NP, NP, (Ref. NTEP CC 02-06) at the field site by authorized Gilbarco service providers. When adding the DEF module to an existing Encore Diesel dispenser, an ID badge on the retrofit kit indicates the DEF upgrade kits model and serial number. This new label will also state that this dispenser has been modified by adding a Gilbarco DEF Module ENC-DEF- RF Gilbarco will also provide a new supplemental ID badge which will be added to the Encore dispenser adjacent to the dispensers existing ID badge located inside the units electronic enclosure. This new supplemental ID badge will state that this dispenser has been modified by adding a Gilbarco DEF Module (ENC-DEF-RF). The new model number NPA or NPB is covered under NTEP CC The supplemental ID badge will allow W&M officials to see both the original and supplemental marking labels. The original ID badge contains additional information needed by service companies and other regulatory officials. W&M's officials should note that the dispenser s original serial number remains the same and two products Diesel and DEF will need to be tested. The addition of this DEF module does not invalidate the certificate on the existing unit. No additional testing was deemed necessary as all components in the DEF module were previously tested under NTEP CC The manufacturer updated the photo of the Diesel and DEF dispenser. Certificate of Conformance Number 09-06: This certificate is issued for a Gilbarco Encore Model NA, NPA and NPB noting a new Coriolis meter, Endress & Hauser LPG mass DN15 for Encore 500. The dispenser with the new Coriolis meter was evaluated and tested at the manufacturer's facility using the 2009 edition of NCWM Publication 1 as the basis for the evaluation. The meter was placed into the manufacturer's Encore series dispenser for testing. Reference NTEP CC A1 for all prior testing of all features and options. Emphasis of this test was to assure that the new meter communicated accurately with the Encore series electronics, that the Encore electronics could calibrate the meter and that the combination of the new meter and Encore electronics was stable and accurate. Volumetric accuracy testing was done at 5 flow rates (1,, 5, 7 10 GPM) with a minimum of drafts per flow rates for both the initial and subsequent test. The meter was retested after having dispensed 2090 gallons of DEF. It is noted that the DEF dispenser is provided with a heater to prevent the DEF from freezing and damaging the meter, valves, piping etc. While provided with a heater, DEF is not a heated product. The heater only works at the temperature approaching the DEF freezing point. The unit is also provided with a means to not allow or to stop DEF product flow if the DEF product temperature reached a temperature that is beyond the ability of the heater to maintain the product temperature i.e. power outage during a very cold period. This feature was tested. Evaluated By: J. Butler, A. Katalinic (NC) 09-06; J. Butler (NC) 09-06A1, J. Butler (NC) 09-06A2, A. Katalinic (NC) 09-06A Type Evaluation Criteria Used: NIST, Handbook : Specifications, Tolerances and Other Technical Requirements for Weighing and Measuring Devices, NCWM, Publication 1: Measuring Devices, Conclusion: The results of the evaluation and information provided by the manufacturer indicate the device complies with applicable requirements. Information Reviewed By: J. Truex (NCWM) 09-06, 09-06A1, 09-06A2, 09-06A
11 Page 11 of 11 Examples of Device: Encore DEF Only Encore Diesel and DEF DEF Module
Standard Features and Options M07300A001*1, M07300A002*1, M07300A003*1, M07300A004*1, M07300A005*1, M07300A006*1
Page 1 of 28 For: Retail Motor Fuel Dispenser (RMFD) Electronic Computing Model: Nxx Series (See Page 3 for Model Designation) Generic Names: Encore 300, Encore 300S, Encore 500, Encore 500S, Encore 550,
More informationCommittee Chair, National Type Evaluation Program Committee Issued: December 27, M Street, Suite 110 / Lincoln, Nebraska 68508
Page 1 of 6 For: Retail Motor Fuel Dispenser Digital Electronic Computing Model: A(BC/DE)FG-HJK Generic Name: Helix Max. Capacity: $9999.00 Total Sale 999.000 Total Volume $9.999 Total Unit Price Submitted
More informationNozzles Lane-oriented and High-hose Attachment Back-lighted Liquid Crystal Displays (LCD)
Page 1 of 29 For: Retail Motor Fuel Dispenser (RMFD) Electronic Computing Model: Nxx Series (See Page 3 for Model Designation) Generic Names: Encore 300, Encore 300S, Encore 500, Encore 500S, Encore 550,
More informationStandard Features and Options
Page 1 of 5 For: Indicating Element Digital Electronic Models: 200, 205, 210, 210-F, 210-FE, 212-G, 212-G, 215, 220 and 225 n max : 10 000 Accuracy Class: III / III L Submitted By: 203 East Daugherty Street
More informationHigh. performance. Encore
High Handsome ROI. performance. Encore Can new dispensers generate new profit? When you choose the Encore family from Gilbarco Veeder-Root, they can. Whether you re looking for a fresh look, industry leading
More informationGASBOY FLEET & COMMERCIAL
GASBOY FLEET & COMMERCIAL F U E L I N G ATLAS SERIES FUELING EQUIPMENT CONTENTS Gasboy Overview 1 9853 Electronic High Flow 2 9850 Electronic Ultra-Hi 4 9216 Satellite 6 9862 Electronic DEF 8 9872 Electronic
More informationLoad Table See attached wiring diagrams:
The Advantage MPD Single-Hose Dispenser For Bennett and Southwest Foundations Model Number B85 B84 Description The Advantage MPD Three-grade, single-hose (two-sided) The Advantage MPD Three-grade, single-hose
More informationThe Advantage and Optimum Dual and Quad Pumps and The Advantage Super-Hi Dual Pumps
The Advantage and Optimum Dual and Quad Pumps and The Advantage Super-Hi Dual Pumps Related Manuals MDE-2833 MDE-3116 MDE-2755 Pump and Dispenser Site Preparation Distribution Box Installation Manual STP
More informationNational Conference on Weights and Measures Shady Grove Road, Suite 130 Rockville, MD 20850
National Conference on Weights and Measures 15245 Shady Grove Road, Suite 130 Rockville, MD 20850 Page 1 of 5 National Type Evaluation Program Certificate of Conformance for Weighing and Measuring Devices
More informationPT Optimum Series Illustrated Parts Manual
PT-1931 Optimum Series Illustrated Parts Manual Computer Programs All Gilbarco computer programs (including software on diskettes and within memory chips) are copyrighted by, and shall remain the property
More informationAvailable Models and Weights
The Advantage Selectable Blender Dispenser Available Models and Weights Models Description Weight Selectable Blender 36" B7E 3 + 0 (single-sided) B78 3 + 0 (two-sided) B7N 4 + 0 (single-sided) 725 lbs./326
More informationHighline Super-Hi High Gallonage Model No. Description. Load Table. Operating Environment. Performance Requirements
Specifications Highline Super-Hi High Gallonage Model No. Description AC4982A-MS1 Super-Hi Single One-Product Master Dispenser AC7942A-MS1 Super-Hi Master/Satellite Combo Dispenser Load Table See attached
More informationThe Advantage Series. Pump & Dispenser Specifications MDE-3807A
The Advantage Series Pump & Dispenser Specifications MDE-3807A Computer Programs and Documentation All Gilbarco Inc. computer programs (including software on diskettes and within memory chips) and documentation
More informationDimension Series One, Two, Three and Four Grade Dispensers
Dimension Series One, Two, Three and Four Grade Dispensers Model Numbers D00 D01 D02 D03 D04 D05 D0E D0G Dimension One-Grade (One-Sided) Dimension One-Grade (Two-Sided) Dimension Two-Grade (One-Sided)
More informationRelated Manuals Pump and Dispenser Start-Up/Installation Manual Flow Restrictor Installation Manual
MPD -1 and MPD-3 Available Models and Weights Generic Model No. Description Weight RAN1220A MPD-1 Three-Grade Dispenser (Two-Sided) High Profile 970 lbs./436 kgs. RAR1220A MPD-1 Three-Grade Dispenser (Two-Sided)
More informationHighline Standard Gallonage Dispenser. Load Table. Operating Environment. Performance Requirements
Specifications Highline Standard Gallonage Dispenser Model No. AC4921A AC5921A AC6921A Description Highline 111B Single One-Product Dispenser Highline 111B Dual One-Product Dispenser Highline 111B Dual
More informationCreating an ROI. from your EMV migration.
Creating an ROI from your EMV migration. A new payment standard is coming to the United States. Instead of transmitting payment data through a traditional magnetic stripe, credit cards will now have a
More informationNational Type Evaluation Program. Checklists and Test Procedures for Retail Motor Fuel Dispensers
National Type Evaluation Program Liquid Measuring Devices Checklists and Test Procedures for Retail Motor Fuel Dispensers 7. Indicating and Recording Elements Code Reference: G-S.5.1. and G-UR.1.1. General
More information10 COMMONLY ASKED QUESTIONS
10 COMMONLY ASKED QUESTIONS #1 WHERE CAN I GET LABELS FOR ETHANOL BLENDS? #2 CAN I CHECK ETHANOL CONTENT QUICKLY IN THE FIELD? #3 CAN I USE ANY FUEL DISPENSER FOR ETHANOL BLENDING? #4 CAN E-85 BE USED
More informationThese regulations are created pursuant to and of the Colorado Revised Statutes.
DEPARTMENT OF LABOR AND EMPLOYMENT Division of Oil and Public Safety RETAIL NATURAL GAS (CNG/LNG) REGULATIONS 7 CCR 1101-16 [Editor s Notes follow the text of the rules at the end of this CCR Document.]
More informationGREASE CONTROL GUNS GREASE CONTROL GUNS Grease control gun Grease control gun with rigid stem and 3 jaw connector ( ).
MEASURE AND CONTROL GREASE CONTROL GUNS AND ACCESSORIES GREASE METERS OIL CONTROL GUNS AND ACCESSORIES OIL METERS OIL METER ACCESSORIES FLUID CONTROL GUNS FLUID METERS HIGH FLOW IN LINE METERS ADVANCED
More informationTesting CNG. Retail Motor Fuel Dispensers
The s of Testing CNG Retail Motor Fuel Dispensers 1 Certain commercial entities, equipment, or materials may be identified in this presentation in order to describe a procedure or concept adequately. Such
More informationWAYNE OVATION HS ULTRA-HIGH-CAPACITY FUEL & DEF DISPENSERS. The art of speed
WAYNE OVATION HS ULTRA-HIGH-CAPACITY FUEL & DEF DISPENSERS The art of speed The envy of the truck island Loyalty starts at the pump. Wayne Ovation TM HS fuel dispensers add ultra high fueling performance
More informationNSAI Licensed Adaptor Scheme. Guidance Document for. Individual Vehicle Approval (IVA)
NSAI Licensed Adaptor Scheme Guidance Document for Individual Vehicle Approval (IVA) AD-69-02 Rev: 01 IVA Guidance for Special Purpose Vehicles Since the 29th of April 2012 a Special Purpose Vehicle (SPV)
More informationCOMPAC PRODUCT RANGE
COMPAC PRODUCT RANGE Backed by over 30 years experience manufacturing fuel pumps and dispensers and using the latest in electronic and software technology Compac has designed and developed a range of intelligent
More informationSK700-II THE COMPLETE DISPENSING SOLUTION. Building Better Business
SK700-II THE COMPLETE DISPENSING SOLUTION Building Better Business Why Gilbarco Veeder-Root? Our experience and expertise in the fuelling industry means we understand a forecourt s business and consumer
More informationADOPTED REGULATION OF THE STATE SEALER OF WEIGHTS AND MEASURES. LCB File No. R Effective December 14, 1998
ADOPTED REGULATION OF THE STATE SEALER OF WEIGHTS AND MEASURES LCB File No. R146-98 Effective December 14, 1998 EXPLANATION Matter in italics is new; matter in brackets [ ] is material to be omitted. AUTHORITY:
More informationParts Certificate Certificate for a part of a measuring system for LOTW
No. 107030 Wayne ixpay TX secure payment platform, a payment terminal (OPT) for cards Issued to Wayne Fueling Systems Sweden AB Hanögatan 10, SE-211 24 Malmö, Sweden In respect of (part of instrument)
More informationExhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)
Exhibit 5 Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle) Definitions common to all certification and test procedures are in: D-200 Definitions for Vapor
More informationEnhanced Vapor Recovery and In-Station Diagnostics. Presented by: Matthew Schuessler, N Cal Territory Mgr 1
Enhanced Vapor Recovery and In-Station Diagnostics Presented by: Matthew Schuessler, N Cal Territory Mgr 1 The Healy EVR Phase II Vac-Assist solution Based on the August 1999 CARB ORVR certified Healy
More informationWELMEC European cooperation in legal metrology
WELMEC 10.6 Issue 1 WELMEC European cooperation in legal metrology Guide for Sealing of Fuel Dispensers (Measuring Systems for Liquids other than Water) May 2008 1 WELMEC European cooperation in legal
More informationLegal Metrology Control of a Liquefied Petroleum Gas Transfer Standard and Field Practice
Legal Metrology Control of a Liquefied Petroleum Gas Transfer Standard and Field Practice Kun-Chih Tsai, Win-Ti Lin, Jiunn-Haur Shaw, Cheng-Tsair Yang, Chun-Min Su Center for Measurement Standards, CMS/ITRI
More informationAutomatic Temperature Compensation Steering Committee. Progress Report January 28, 2008 Albuquerque, NM
Automatic Temperature Compensation Steering Committee Progress Report January 28, 2008 Albuquerque, NM Background Year 2000: S&T presents item to address ATC in H44 VTM Code L&R presents item to recognize
More informationPCI (Payment Card Industry)
PCI (Payment Card Industry) Irving Oil Marketing, Inc July 2009 Last Updated 9/2/09 There are hundreds of requirements in the PCI-DSS document, it is best to compartmentalize them into manageable buckets
More informationDISPENSING SYSTEMS
DISPENSING SYSTEMS 800-621-4137 www.whyips.com Retail Dispensers Encore 700S Dispensers Dispenser Features: Secure your competitive advantage and increase profits with Gilbarco Veeder Root s Encore 700S
More informationBennett Horizon 2 Series Electronic
Bennett Horizon 2 Series Electronic with 708 Electronics Parts Manual Only Trained Personnel May Work on This Equipment Includes Instructions For: Self Contained Remote High Hose Low Hose Card Reader Local
More informationidentifuel System Overview
identifuel System Overview Fueling Automation System Executive Summary identifuel is a set of easy to integrate components for Fuel Management Systems (FMS), enabling fleet managers to monitor and control
More informationINSTALLATION INSTRUCTIONS
A4005EVR Balance Vapor Recovery Nozzle RA4005EVR = Rebuilt XXX = Scuff Guard Color Permanent ID Information: Emco Logo on Boot Connector Emco Logo on Scuff Model No. on Spout Emco Wheaton Security Rivet
More informationPlease note: upgrades from older fluorescent backlit displays (Q ) will require PMP Adapter Kit #62071 or equivalent
Thank you for purchasing the enclosed PMP retrofit display. This display is designed and manufactured by PMP as a replacement for the Gilbarco Monochrome QVGA Display (M02636A001). The kit includes: (1)
More informationEmco Logo on Scuff INSTALLATION INSTRUCTIONS
For use with Vapor Systems Technologies VST California Air Resources Board Executive Orders VR-203 and VR-204 A4005EVR Balance Vapor Recovery Nozzle RA4005EVR = Rebuilt XXX = Scuff Guard Color Permanent
More informationRML2000. Installation Manual. Measurement systems for the future, from the trusted name in metering...neptune.
M-614(C) 09/06 RML Inst. RML2000 Installation Manual IMPORTANT: To assure proper installation of this product, thoroughly review the information in this revision of the manual. Information is subject to
More informationNational Board Update
National Board Update Presentation to the Valve Repair Council June 2, 2016 Prepared by: Joseph F. Ball, P.E. National Board Update National Board activities Who we are and what we do National Board Inspection
More informationElectronic Assemblies, Dials & Schematics. Electronic Enclosure Assembly (1 and 2 lamp system) , 3-3 (3 and 6 lamp system)...
Section Three Electronic Assemblies, Dials & Schematics Page Number Electronic Enclosure (1 and 2 lamp system)... 3-2, 3-3 (3 and 6 lamp system)... 3-4, 3-5 Electronic Component and Power Supply... 3-5,
More informationCalifornia Department of Food and Agriculture Division of Measurement Standards Petroleum Products Program Fuels and Lubricants Laboratory
California Department of Food and Agriculture Division of Measurement Standards Petroleum Products Program Fuels and Lubricants Laboratory NH3 Fuel Association The Tenth Annual NH3 Fuel Conference September
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment
More informationSFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies
SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and
More informationWAYNE HELIX TM FUEL DISPENSER ALTERNATIVE ENERGY SOLUTIONS. Designed for you. world
WAYNE HELIX TM FUEL DISPENSER ALTERNATIVE ENERGY SOLUTIONS Designed for you. Engineered world for the Prepare your forecourt for the eco invasion Hybrid vehicles using LPG (Liquefied Petroleum Gas), ethanol,
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-29010-8 SOUTH AFRICAN NATIONAL STANDARD Homologation of motor vehicle models Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12
More informationDepartment of Agriculture Weights and Measures Services Division MAY 9, 2017
Department of Agriculture Weights and Measures Services Division MAY 9, 2017 Agenda New Vapor/Fuel Compliance Manager Skimming Devices at Fueling Locations Stage II Decommissioning Proposed Rules Mark
More informationUser's Guide 2.0. Version FEBRUARY 2000
User's Guide 5872 Version 2.0 FEBRUARY 2000 MANUAL HISTORY Date of issue for original version and subsequent versions: Version 1.0... July 1999 Version 2.0... February 2000 NOTE: If entries are shown in
More informationStandards Are Fit For Use Standard must be free of leaks, dents and seals must be intact
Test Procedures for Inspecting Fuel Dispensers (90 liters/min or less) 1. Standards 2. Device Use 3. Visual Exam 4. Performance 5. Sealing Physical Standards Physical Standards Certified Within Prescribed
More informationD. Operation and Maintenance Data. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following:
SECTION 16211 - ELECTRICITY METERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationOIML CERTIFICATE OF CONFORMITY
Member State of OIML United Kingdom of Great Britain and Northern Ireland OIML CERTIFICATE OF CONFORMITY Issuing authority: Person responsible: Applicant: Manufacturer: Identification of the certified
More informationPropeller Meters. Flow measurement solutions for water and wastewater
Propeller Meters Propeller Meters Flow measurement solutions for water and wastewater Perfect flow measurement solutions Water Specialties Propeller Meters are designed and manufactured with precise techniques
More informationSelecting Weights and Certificates
11 Weight Selection There are several shapes, designs and sizes available to meet your needs. Selecting the proper weight for your application can be confusing given the number of weight classes, designs,
More informationDiesel Exhaust Fluid Certification Program Overview FEBRUARY 2009 REVISION 01
Diesel Exhaust Fluid Certification Program Overview Foreword This overview describes the voluntary and is intended to explain to marketers how the API Diesel Exhaust Fluid Certification Mark is licensed
More informationRFS2: Where Are We Now And Where Are We Heading? Paul N. Argyropoulos
Agricultural Outlook Forum Presented: February 24-25, 2011 U.S. Department of Agriculture RFS2: Where Are We Now And Where Are We Heading? Paul N. Argyropoulos Office of Transportation and Air Quality
More informationBENNETT CNG DISPENSER MAINTENANCE SCHEDULE
BENNETT CNG DISPENSER MAINTENANCE SCHEDULE Serial #: DIN #: Company Name: CAUTION: Only trained personnel may work on dispensers. CAUTION: The emergency shut off valve if installed must be closed. CAUTION:
More informationEPO No. 28. Examination Procedure Outline (EPO) for. Compressed Natural Gas (CNG) Retail Motor-Fuel Dispensers
EPO No. 28 Examination Procedure Outline (EPO) for Compressed Natural Gas (CNG) Retail Motor-Fuel Dispensers It is recommended that this outline be followed as minimum criteria for examining retail motor-fuel
More informationSFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines
SFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes
More informationPFI Standard Specification for Residential/Commercial Densified Fuel 18-June-2008
Pellet Fuel Institute (PFI) Standard Specification for Residential/Commercial Densified Fuel 1. Scope 1.1 This specification is applicable for the determination of fuel quality grade for Residential or
More informationChapter 2. The Vehicle-Tank Metering System
Chapter 2 The Vehicle-Tank Metering System Chapter Objectives Upon completion of this chapter, you should be able to: 1. Describe the vehicle-tank metering system, its uses, and its relation to other liquid-volume
More informationEvaluation Certificate
SC0414-14 Certificate for a part of a measuring system for LOTW Forecourt controller, FuelNet Manager Issued to CODAB AB Höjdrodergatan 24, SE-212 39 Malmö, Sweden In respect of (part of instrument) Forecourt
More informationVda 6 5 Process Audit Satips
We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with vda 6 5 process audit
More informationInformation Sheet. concerning the Issuing of Multi-stage Typeapprovals in accordance with Directive 2007/46/EC (MMT) Version: March 2016.
Information Sheet concerning the Issuing of Multi-stage Typeapprovals in accordance with Directive 2007/46/EC (MMT) Version: March 2016 Typeapproval Contents Page 1 Introduction... 4 2 Definitions...
More informationMALAYSIA 2174 ENFORCEMENT OFFICERS IN 86 OFFICE IN MALAYSIA RATIONALE FOR LEGAL METROLGY LEGISLATION RATIONALE FOR LEGISLATION
I. GENERAL INFORMATION MALAYSIA Population Size Domestic Trade per million population (in US$) (2007) Departmental Budget per million population (in US$) (2007) Staff Strength 27.17 MILLION GROSS DOMESTIC
More informationSalesmaker Series Pumps And Dispensers Illustrated Parts Manual
PT-599B Salesmaker Series Pumps And Dispensers Illustrated Parts Manual For use with -H, -4A and Pro-Blender COMPUTER PROGRAMS All Gilbarco computer programs (including software on diskettes and within
More informationSFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 *
SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 * PRODUCT: Replacement Flywheels and Clutch Assemblies 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum
More informationSK700-II LPG. Easy LPG solutions adapted to fit your needs
SK700-II LPG Easy LPG solutions adapted to fit your needs > Seamless LPG integrations with SK700-II > Standalone and combi versions available > ATEX and MID approved > Field proven LPG hydraulics design
More information2011 Alternative Fueling Infrastructure Catalog
2011 Alternative Fueling Infrastructure Catalog Atlanta GA (800) 241-4155 Kansas City MO (800) 821-5062 Dallas TX (800) 821-1829 SINCE 1937 Fayetteville NC (800) 447-1625 Houston TX (800) 334-7816 Little
More informationOIML CERTIFICATE OF CONFORMITY
Member State of OIML United Kingdom of Great Britain and Northern Ireland OIML CERTIFICATE OF CONFORMITY Issuing authority: Person responsible: Applicant: Manufacturer: Identification of the certified
More informationNPS Series. Pallet Jack Scale Operator s Guide (V1611)
NPS Series Pallet Jack Scale Operator s Guide (V1611) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com Fax: +1 866 612 9088 North America Toll Free: 1-855-ANYLOAD (269 5623)
More informationNISTM Conference 4/16/2016. Meter Calibration, Skimmers & Fuel Theft
NISTM Conference 4/16/2016 Meter Calibration, Skimmers & Fuel Theft AccuMeasure Updates Nationwide Tested~ 185,993 Fueling Points in 2015. Calibrated 92,004 meters in 2015. Average variance before calibration.984
More informationEI HMC Report Spring API Committee on Petroleum Measurement Standards Meeting
EI HMC Report 2017 Spring API Committee on Petroleum Measurement Standards Meeting STAC EI Technical Committee Structure STAC Health Technical Committee Environmental Management Group Safety Management
More informationE/ECE/324/Rev.1/Add.50/Rev.3/Amend.2 E/ECE/TRANS/505/Rev.1/Add.50/Rev.3/Amend.2
26 April 2018 Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and the
More informationTechnical Service BULLETIN
Technical Service BULLETIN February 8, 2005 Title: Models: 04 05 Camry (V6) EG009-05 ENGINE Introduction Under certain driving conditions, some 2004 and 2005 model year Camry vehicles may exhibit a M.I.L.
More informationAlternative Fuel Price Report
July 2016 Natural Gas Ethanol Propane Biodiesel CLEAN CITIES Alternative Fuel Price Report Welcome to the July 2016 issue! The Clean Cities Alternative Fuel Price Report is a quarterly report designed
More informationPosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)
PosiTest Pull-Off Adhesion Tester INSTRUCTION MANUAL v. 4.0 PosiTest AT-M (manual) PosiTest AT-A (automatic) Introduction The portable, hand-operated PosiTest Pull-Off Adhesion Tester measures the force
More informationAPPROVE ESE OFFICE WORK INSTRUCTIONS
Page 1 Office Work Instruction B Effective Date: May 12, 2000 Responsible Office: YB/Business Management Division Subject: APPROVE ESE OFFICE WORK INSTRUCTIONS OFFICE WORK INSTRUCTION APPROVE ESE OFFICE
More informationERROR RECOVERY ERR R O C D O ES / REC V O E Y R PR C O EDURES E
ERROR RECOVERY ERROR CODES / RECOVERY PROCEDURES Error Code TDM 00/50 Mech 0 (MiniMech) Meaning Recovery Procedure X Feed failure 4 X Mistracked note at feed 5 X Mistracked note at double detect X Mistracked
More informationCERTIFICATE OF APPROVAL
Certificate 1584 Overseas Certificate No: 5/6A/91A Wellington, New Zealand CERTIFICATE OF APPROVAL Weights and Measures Regulations 1999 Part 1 Regulations 5 and 6 This certifies that the Compac MR40P,
More informationCenturytm Series Fuel Dispenser
Centurytm Series Fuel Dispenser Dresser Wayne Century Series Fuel Dispenser The Dresser Wayne Century Series fuel dispenser combines the benefits of fast fueling with the value of a compact design. It
More informationPhase-Two Water Detector
Phase-Two Water Detector Frequently Asked Questions Sections: Background on Phase Separation Fuel Compatibility Equipment Compatibility Phase-Two Operability Background on Phase Separation 1. What is phase
More informationEPA Emission Requirements:
DEF 101 EPA Emission Requirements: In 2010 the Environmental Protection Agency, OEMs, and many trucking fleets committed themselves to a cleaner environment by reducing NOx emissions. To reduce NOx emissions,
More informationSK700-II ADBLUE ADBLUE DISPENSERS ADAPTED TO FIT YOUR NEEDS
SK700-II ADBLUE ADBLUE DISPENSERS ADAPTED TO FIT YOUR NEEDS > Standalone, Combi or Integrated > Ensures maximum uptime and damage free filling > A reliable solution to meet any customer needs > Also available
More informationDEF DISPENSING AND STORAGE
Benecor Catalog Table of Contents DEF Dispensing and Storage... 1-0 Tote Dispensers... 1-1 Drum/Barrel Dispensers.... 1-2 Island Dispensers.... 1-3 Bulk Compact Dispensers.... 1-4 Bulk Flexstand Dispensers....
More informationTEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000
Page 1 of 15 Report No 130313TRFENV Report Reference No.... : TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 130313TRFENV Tested by... : Alessio Pelizzoni. Verified by... : Fabio Mauri. Date of issue...
More informationINTELLITROL. scully. Scully s Intellitrol System. Intellitrol is a state of the art microprocessor based system that provides:
INTELLITROL Overfill Prevention Control Unit with Optional Ground Verification and Vehicle Identification Features. Scully s Intellitrol System is the most advanced terminal overfill prevention and ground
More informationSpecial Specification 6058 Battery Back-Up System for Signal Cabinets
Special Specification Battery Back-Up System for Signal Cabinets 1. DESCRIPTION 2. DEFINITIONS Install a Battery Back-Up System (BBU System) for traffic signals that will provide reliable emergency power
More informationKEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER
INSTRUCTION MANUAL STEERING WHEEL TORQUE/ INCLINOMETER SYSTEM MODEL KEI-234 W / INTERNAL BARCODE SCANNER REVISION DATE: 17-AUG-1999 1 GENERAL DESCRIPTION... 3 INSTALLATION... 3 SYSTEM SETUP... 4 To change
More informationOhio Alternative Fuel Vehicle Conversion Grant Program. Information Session January 25, 2018 Updated February 27, 2018
Ohio Alternative Fuel Vehicle Conversion Grant Program Information Session January 25, 2018 Updated February 27, 2018 Today s Presentation Highlights only Based on weight, not vehicle class Getting costs
More informationAppendix C SIP Creditable Incentive-Based Emission Reductions Moderate Area Plan for the 2012 PM2.5 Standard
Appendix C SIP Creditable Incentive-Based Emission Reductions This page intentionally blank. Appendix C: SIP Creditable Incentive-Based Emission Reductions Appendix C: SIP Creditable Incentive-Based Emission
More informationNZQA registered unit standard 9076 version 4 Page 1 of 5
Page 1 of 5 Title Repair vehicle chassis damage Level 4 Credits 10 Purpose This unit standard is for people who work in the collision repair industry. People credited with this unit standard are able to
More informationMC-CRX. Bill Acceptor Card Reader Combo. Operation & Service Manual
MC-CRX Bill Acceptor Card Reader Combo Operation & Service Manual TABLE OF CONTENTS SECTION 1: GENERAL INFORMATION Introduction...4 Features...4 For Records...4 After Unpacking...4 Naming Convention...5
More informationAPPLICATION FOR PRODUCT / ECO-LABELLING CERTIFICATION. GPS Coordinates. GPS Coordinates. Fax No. H/P No.
epcs/for/01-2 SIRIM QAS International Sdn. Bhd. (410334-X) SIRIM Complex, No. 1, Persiaran Dato Menteri, P.O. Box 7035, 40700 Shah Alam, Selangor Darul Ehsan, Malaysia. Tel: 603-5544 6402 Fax: 603-5544
More information600 Amp Surge Arrester
R&D Center 497 Schooley s Mountain Road Hackettstown, NJ 07840-3906 Tele: 908-852-1122 Fax: 908-813-2091 TEST REPORT NUMBER: 379-17-12164 DATE: 4-3-2012 REPORT OF TEST ON 600 Amp Surge Arrester Statements
More informationOne Solution You Can Trust!
Enhanced Vapor Recovery and In-Station Diagnostics One Company One Order One Phone Call One Solution You Can Trust! From the only company who can offer a complete solution! VRM Vapor Recovery Monitoring
More informationSmartVend Water Dispenser Manual Version R.5
SANDVAULT GROUP SmartVend Water Dispenser Manual Version R.5 SmartVend Water Dispenser Manual, Version R.5 Notice The information contained in this manual has been researched and prepared according to
More informationParts List GoPump C-series & R-series, Spec 2000 or Higher
Parts List GoPump C-series & R-series, Spec 000 or Higher Table of Contents Dispenser Identification Number for GoPump... 3 Model Number Overview, How to Order, Contact Information... 4 Front View of the
More informationBy the Book: How to Offer E15
By the Book: How to Offer E15 In 2012, the U.S. Environmental Protection Agency (EPA) approved the use of E15 fuels in 2001 and later model year vehicles and all flex-fuel vehicles (FFVs). EPA has specifically
More information