1 Australian/New Zealand Certification Scheme for EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZEx Scheme Certificate of Conformity Certificate No.: ANZEx Issue No.: 0 Date of Issue: 31/01/2014 Applicant: Electrical Apparatus: Elmako Pty Ltd trading as Wattmaster 54 Lakewood Boulevard Carrum Downs Vic 3201 Australia HAW Range of Alco Cable Glands Type of Protection: Ex db I/IIC, Ex eb I/IIC, Ex ta IIIC Marking Code: Manufacturer: Manufacturing Location(s): Alco ALCHAW... M.. Ex db I/IIC, Ex eb I/IIC, Ex ta IIIC ANZEx Elmako Pty Ltd trading as Wattmaster 54 Lakewood Boulevard Carrum Downs Vic 3201 Australia Elmako Pty Ltd trading as Wattmaster 54 Lakewood Boulevard Carrum Downs Vic 3201 Australia The EPEE certification database located at shows the validity of this Certificate. This certificate and schedule shall not be reproduced except in full Certificate issued by: TestSafe Australia 919 Londonderry Road, Londonderry NSW 2753 Australia Phone: Fax: EPF019_17 Page 1 of 7
2 Australian/New Zealand Certification Scheme for EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZEx Scheme Certificate of Conformity Certificate No.: ANZEx Issue No.: 0 Date of Issue: 31/01/2014 This certificate is granted subject to the conditions as set out in Standards Australia/Standards New Zealand Miscellaneous Publication MP87.1:2008. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC :2007 IEC :2007 IEC :2006 IEC :2008 Explosive atmospheres Part 0: Equipment General requirements Explosive atmospheres Part 1: Equipment protection by flameproof enclosures d Explosive atmospheres Part 7: Equipment protection by increased safety e Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure t This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standard(s) listed above. ASSESSMENT & TEST REPORTS: The equipment listed has successfully met the assessment and test requirements as recorded in: Test Report No. and Issuing Body: 33003, TestSafe Quality Assessment Report No. and Issuing Body: AU/TSA/QAR /01, TestSafe File Reference: 2008/ Ujen Singh 31/01/2014 Signed for and on behalf of issuing body Date of Issue Quality & Certification Manager Position This certificate is not transferable and remains the property of the issuing body and must be returned in the event of it being revoked or not renewed. This certificate and schedule shall not be reproduced except in full EPF019_17 Page 2 of 7
3 Australian/New Zealand Certification Scheme for EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZEx Scheme Certificate of Conformity Certificate No.: ANZEx Issue No.: 0 Date of Issue: 31/01/2014 Schedule EQUIPMENT: The HAW range of Alco cable glands is suitable for inserting circular steel wire armoured cables into flameproof (Ex d) enclosures having threaded entries and increased safety (Ex e) or dust ignition protection (Ex t) equipment having either plain or threaded entries. Each gland may be used as either a compression gland, utilizing the supplied inner seals, or a barrier gland, utilizing the supplied insert which is filled with setting compound. The glands consist of a body, cone, ring, sleeve, inner seal (A or B), outer seal, nut and insert. The nuts are not provided with a lead-in, as the glands are not intended for use with flexible cables. Attachment of the glands to an enclosure is facilitated by means of the male threaded portion on the body. A locknut and flat washer is required for securing glands to equipment having plain entries. The cable wire armour is clamped between the male tapered portion on the cone and the female tapered portion on the ring, when the sleeve is screwed onto the body. An O ring is used to seal the joint between the body and sleeve to prevent dust and moisture ingress to the wire armour clamping facility. The outer seal forms a seal on the outer sheath of the cable, when the outer nut of the gland is tightened. The outer seal also clamps the cable to prevent pulling or twisting forces from being transmitted to the conductor connections. The cable glands are manufactured from brass alloy to Japanese Standard JIS C3604 B, which is nickel plated, and have ISO (1.5 mm pitch) mounting threads. All metallic components of the glands are manufactured from the same material. The inner and outer seals and O rings are made from NBR 1052 Rubber. An entry thread seal made of red fibre is provided for Ex t applications and is required to maintain ingress protection of IP66/IP68 (30 m for 4 hours) for the cable glands. The sealing compound used for the HAW barrier glands is Kneadaseal epoxy putty. When used as compression glands, the cable inner sheath is passed through the appropriate sized inner seal and sealing of the cable is achieved by compressing the inner seal between the body and cone, when the sleeve is screwed onto the body. In this case, the insert is not required. The permissible operating temperature range for the HAW range of compression glands is -20 ºC to +80 ºC. When used as barrier glands, the cable inner sheath is passed through the insert and sealing of the cable is achieved by filling the insert with epoxy putty sealing compound. In this case, the inner seal is not required. The permissible operating temperature range for the HAW range of barrier glands is -20 ºC to +100 ºC. Refer to the instructions supplied by the manufacturer for installation details. The glands may also be used with intrinsically safe circuits, in which case the glands will have specific parts painted light blue. For detailed installation information, refer to the manufacturer s fitting instructions. The HAW Range of Alco cable glands is summarized in the following tables. This certificate and schedule shall not be reproduced except in full EPF019_17 Page 3 of 7
4 Australian/New Zealand Certification Scheme for EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZEx Scheme Certificate of Conformity Certificate No.: ANZEx Issue No.: 0 Date of Issue: 31/01/2014 Gland Code Number Mounting Thread x Length HAW Range (Compression Configuration) Tightening SWA Cable Torque Over Bedding (Nm) Over Cable Inner Seal B Inner Seal A Seal A (outer) Min Max Min Max Min Max Min Max ALCHAW20 M20 x ALCHAW20SB M20 x * * ALCHAW20LR M20 x * * ALCHAW25A M25 x ALCHAW25B M25 x ALCHAW32A M32 x ALCHAW32B M32 x ALCHAW40A M40 x ALCHAW40B M40 x ALCHAW50A M50 x ALCHAW50B M50 x ALCHAW63A M63 x ALCHAW63B M63 x ALCHAW75A M75 x ALCHAW75B M75 x ALCHAW90A M90 x ALCHAW90B M90 x Gland Code Number Mounting Thread x Length HAW Range (Barrier Configuration) Tightening Torque (Nm) Maximum Single Core Maximum Laid-up Multicore SWA Cable Seal A (outer) Min Max Min Max ALCHAW20LRB M20 x ALCHAW20 M20 x ALCHAW20SB M20 x ALCHAW25A M25 x ALCHAW25B M25 x This certificate and schedule shall not be reproduced except in full EPF019_17 Page 4 of 7
5 Australian/New Zealand Certification Scheme for EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZEx Scheme Certificate of Conformity Certificate No.: ANZEx Issue No.: 0 Date of Issue: 31/01/2014 Gland Code Number Mounting Thread x Length Tightening Torque (Nm) Maximum Single Core Maximum Laid-up Multicore SWA Cable Seal A (outer) Min Max Min Max ALCHAW32A M32 x ALCHAW32B M32 x ALCHAW40A M40 x ALCHAW40B M40 x ALCHAW50A M50 x ALCHAW50B M50 x ALCHAW63A M63 x ALCHAW63B M63 x ALCHAW75A M75 x ALCHAW75B M75 x ALCHAW90A M90 x ALCHAW90B M90 x HAW Range (Barrier Configuration) Maximum laid-up core diameter and number of cores Gland Code Maximum Number of Cores of Indicated Conductor CSA (mm 2 ) Number 0.6/1 kv Cables to AS/NZS 5000 ELV Instrumentation Cables ALCHAW20LRB * * * 12 7 ALCHAW * * * 12 7 ALCHAW20SB * * * ALCHAW25A * ALCHAW25B ALCHAW32A ALCHAW32B ALCHAW40A * * * 72 ALCHAW40B * * * * 100 ALCHAW50A * * * * * * ALCHAW50B * * * * * * * * * * This certificate and schedule shall not be reproduced except in full EPF019_17 Page 5 of 7
6 Australian/New Zealand Certification Scheme for EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZEx Scheme Certificate of Conformity Certificate No.: ANZEx Issue No.: 0 Date of Issue: 31/01/2014 Gland Code Number Maximum Number of Cores of Indicated Conductor CSA (mm 2 ) 0.6/1 kv Cables to AS/NZS 5000 ELV Instrumentation Cables ALCHAW63A * * * * * * * * * * ALCHAW63B * * * * * * * * * * ALCHAW75A * * * * * * * * * * ALCHAW75B * * * * * * * * * * ALCHAW90A * * * * * * * * * * ALCHAW90B * * * * * * * * * * Notes: 1) For 5 core and above, any earth core has been considered full size and is included in the number of cores. 2) For conductors greater than 16 mm 2, the largest number of permitted cores is 4 plus any required earth core/s. 3) The information above is based on the available information from cable manufacturers. Cables may vary in size between manufacturers and between batches. Accordingly, this information is provided as a guide only. CONDITIONS OF CERTIFICATION: None. DOCUMENTS: Document Number Document Title Revision Date HAW20-15/09/ HAW20 Markings - 06/02/ HAW25A - 15/09/ HAW25A Markings - 06/02/ HAW25B - 15/09/ HAW25B Markings - 06/02/ HAW32A - 15/09/ HAW32A Markings - 06/02/ HAW32B - 15/09/ HAW32B Markings - 06/02/ HAW40A - 15/09/ HAW40A Markings - 06/02/ HAW40B - 15/09/ HAW40B Markings - 06/02/ HAW50A - 15/09/2003 This certificate and schedule shall not be reproduced except in full EPF019_17 Page 6 of 7
7 Australian/New Zealand Certification Scheme for EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZEx Scheme Certificate of Conformity Certificate No.: ANZEx Issue No.: 0 Date of Issue: 31/01/2014 Document Number Document Title Revision Date HAW50A Markings - 06/02/ HAW50B - 15/09/ HAW50B Markings - 06/02/ HAW63A - 15/09/ HAW63A Markings - 06/02/ HAW63B - 15/09/ HAW63B Markings - 06/02/ HAW75A - 15/09/ HAW75A Markings - 06/02/ HAW75B - 15/09/ HAW75B Markings - 06/02/ HAW90A - 15/09/ HAW90A Markings - 06/02/ HAW90B - 15/09/ HAW90B Markings - 06/02/ HAW20SB - 17/03/ HAW20SB Markings - 06/02/ HAW20LR - 16/07/ HAW20LR Markings - 06/02/ HAW20LR Barrier - 16/07/ HAW20LR Barrier Markings - 06/02/2013 ALCHAWGEN Elmako Pty Ltd Alco Glands HAW Range Contents /09/2012 ALCHAWSPEC Elmako Pty Ltd Alco Glands /09/2012 HAW Range Specifications ALCHAWFLMPTH Elmako Pty Ltd Alco Glands - HAW Range /05/2005 Flameproof Joint Data ALCHAWBARLIM Alco - HAW Range - Barrier Glands Maximum Laidup /05/2005 Core and Number of Cores ALCHAWSCHDRG Alco Glands - Schedule of Drawings HAW Range - Hazardous Area, Armoured Weatherproof /05/2012 This certificate and schedule shall not be reproduced except in full EPF019_17 Page 7 of 7
8
9
10
11
12
13
14
15
Certificate of Conformity
Australian/New Zealand Certification Scheme for EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZEx Scheme Certificate of Conformity Certificate No.: ANZEx 13.3001 Issue No.: 0 Date of Issue: 31/01/2014 Applicant:
More informationCertificate of Conformity
Applicant: Ascomation Pty Ltd Unit 12/25 Frenchs Forest Road East Frenchs Forest NSW 2086 Electrical Apparatus: Type of Protection: Solenoids Type AIS, AISV/AISVT, JAIS, JPAIS/JPETAIS, JSAIS/JSETAIS &
More informationCertificate of Conformity
Certificate Holder: Moore Industries - International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A. Electrical Apparatus: Flameproof Transmitter Enclosure Models LH2XSA and BHabcA Type of
More informationCertificate of Conformity
Applicant: Compac Industries Ltd 52 Walls Road, Penrose Auckland 1061, NEW ZEALAND Electrical Apparatus: Series Fuel Dispensers Type of Protection: Marking Code: Manufacturer: Manufacturing Location(s):
More informationABG Cable Glands Installation Procedure
ABG Cable Glands Installation Procedure ABG Cable Gland Range Baseefa 16ATEX0004X IECEx BAS 16.0011X Installation, Operation and Maintenance Instructions Material: Brass/ Brass with Nickel plated and Stainless
More informationsira CERTIFICATION KSG, KSGDS and KCG Range of Cable Glands
KSG, KSGDS and KCG Range of Cable Glands This range of cable glands is intended for use with any cable type where sealing and retention is required by gripping the outer sheath (this includes armoured/screened/braided
More informationArmoured / Un-armoured Cable Gland
Armoured / Un-armoured Application These cable glands are used ; suited to armoured/un-armoured cables used mainly in areas where British Standards apply. particularly suited to Steel Wire Armoured. compliance
More informationSEALSAFE PRODUCTS CONDUIT AND CABLE PRODUCTS. for HARSH AND HAZARDOUS ENVIRONMENTS. Certificate ANZEx
SEALSAFE PRODUCTS CONDUIT AND CABLE PRODUCTS for HARSH AND HAZARDOUS ENVIRONMENTS Certificate ANZEx 09.3018 SEALSAFE ZONE 1 HAZARDOUS AREA CONDUIT AND FITTINGS Sealsafe provides a range of nickel plated
More informationIECEx Certificate of Conformity
Certificate of Conformity: IECEx BAS 07.0033X http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/9e9052... Page 1 of 4 18/06/2008 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:
More informationADE 6F ADE 6F. page 46
ADE 6F 6 F U N C T I O N S : D O U B L E C L A M P I N G > For armoured cable > IP68 > Compliance > EX 60079-0 2009 Performance > Nickel plated brass standard finishing > Optional : stainless steel, aluminium
More informationThe safety you rely on.
Cable Glands Global Solutions Catalogue The safety you rely on. Cable Glands & Accessories Global Solutions Introducing Crouse-Hinds by Eaton The leader in electrical products for hazardous, industrial
More informationAppleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.
ppleton s TX product line includes a wide selection of both Increased Safety and lameproof cable glands for use with unarmored and armored cable. ppleton's TX cable glands are available in a wide range
More informationAmphenol Cable Glands and Cord Grips Amphenol
Amphenol Cable Glands and Cord Grips 12-055-1 Amphenol Table of Contents Page Number Introduction 1 Amphenol Cable Glands 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationTECHNICAL BULLETIN. Sandvik MB670 Bolter Miners
TECHNICAL BULLETIN 1(2) TB1212 August 01, 2012 TOPIC: CONCERNS: MORLEY EMW 32 S 132 KW HYDRAULIC PUMP MOTOR GLAND ADAPTER PLATE CERTIFICATION This technical bulletin is applicable to Sandvik Bolter Miners
More informationIECEx Certificate of Conformity
Annex Page 1 of 8 Equipment: The E** series Type ranges of cable glands consist of a male-threaded front entry component containing an elastomeric sealing ring and a Nylon 6 skid washer which effect flameproof
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:
More informationADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel
ADE 4F 4 F U N C T I O N S : D O U B L E > For armoured cable > IP68 > Compliance > EX 60079-0 2009 Performance > Nickel plated brass and stainless steel > Optional : aluminium and bronze raw material
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2012-06-12 Issue No.: 3 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Germany Manufacturing
More informationPratley Ezee-Fit Box Replacement Gaskets Replacement Gasket for the Pratley Ezee-Fit Box
Pratley Ezee-Fit Box Covers Ex e/n Either standard or polycarbonate (transparent) Supplied complete with stainless steel cheese head screws and rubber gasket ready to fit Pratley Ezee-Fit Box Replacement
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2014-04-01 Issue No.: 4 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Additional Manufacturing
More informationProduct manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands
Product manual cable glands type IR and IB INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions
More informationPosition Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More informationCompact temperature switch Model TCS
Mechatronic temperature measurement Compact temperature switch Model TCS WIKA data sheet TV 31.64 Process Compact Series Applications Temperature monitoring and control of processes Safety-critical applications
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationPosition Switches Series 8060/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationInstallation Guidelines For BW Gland
Installation Guidelines For BW Gland Address: Raychem RPG Pvt. ltd. 1/62, M G Road, Off. Western express highway, Near Bharat Petroleum, Valiv Village, Post Sativali, Vasai (E) 401208, Maharashtra, India.
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical
More informationCapri ADE 6F - for Armoured Cable
Capri ADE 6F - for Armoured Cable Technical Specification Suitable for the following cable types Steel wire armoured cable (SWA) Steel wire braided cable (SWB) Steel tape armoured cable (STA) Braided marine
More informationPosition Switches Series 8070/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationADJUSTABLE CABLE GLANDS
ISO CE R TIF IC AT N IO Intertek TM MANAGEMENT SYSTEMS ADJUSTABLE CABLE GLANDS NICKEL PLATED BRASS Modest Torque Produces Huge Armour Clamping Forces APPROVED SANS SANS IP If fitted with Gasket, Inner
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE
More informationEX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22.
EX CABLE GLANDS FOR HAZARDOUS AREAS & IECEX Zones, 2, 2 and 22 CABLE GLANDS EX D/E 4 CABLE GLANDS UNARMOURED EX D IP66 - IP68 5 CABLE GLANDS UNARMOURED EX E IP66 - IP68 5 CABLE GLANDS UNARMOURED EX D/E
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 Equipment: Manufacturer: Type: ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2288626 Master Contract: 184585 Issued to: CMP Products Ltd Glasshouse St. St. Peters Newcastle Upon Tyne, NE6 1BS United Kingdom Attention: Dave Willcock The products
More informationKopex-Ex cable glands offer superior protection in hazardous environments
CABE GANDS Kopex-Ex cable glands offer superior protection in hazardous environments For over 100 years, Thomas & Betts has successfully applied innovative design and manufacturing techniques to meet the
More informationLevel 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Delsa Marmi Pty Ltd
Level 1 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Delsa Marmi Pty Ltd Trading as Delsa Marmi Pty Ltd the right to use the WaterMark as shown above
More informationOperating Instructions
Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety
More informationCompact pressure switch Model PCS
Mechatronic pressure measurement Compact pressure switch Model PCS WIKA data sheet PV 33.30 for further approvals see page 4 Process Compact Series Applications Pressure monitoring and control of processes
More informationDirect-acting 3/2 way plunger valve
Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 13.0077U issue No.:1
More informationHolville I.S. Uninterruptible Power Supply Unit (UPS)
Holville I.S. Uninterruptible Power Supply Unit (UPS) The Holville range of intrinsically safe equipment has power outputs specifically designed for use in Group 1 hazardous areas. The range includes Compact
More informationCompact differential pressure switch Models DC, DCC
Mechatronic pressure measurement Compact differential pressure switch Models DC, DCC WIKA data sheet PV 35.40 Process Compact Series Applications Differential pressure monitoring and control of processes
More informationLIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE
Instrum LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE (AI364 Rev 11 05Oct17) Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. OL7 0NA. UK Sales: +44 (0) 161
More informationEVZ Series (Small body) Explosion protected luminaire Operating Instructions
EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East
More informationTechnical Data. Dimensions
Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush
More informationSurface thermocouple Model TC50
Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial
More informationEndress+Hauser Wetzer GmbH+Co. KG Obere Wank Nesselwang Germany. Field Temperature Transmitter itemp, Types TMT82, TMT84 and TMT85
--~---- - ECEx Certificate NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details of the ECEx Scheme visit www.iecex.com ECEx DEK 11.0096 issue No.:O!
More informationGOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS
More information0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable
0.6/1kV - PVC Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS: 1.IEC60502-1;VDE 0276-603 ;ICEA S-95-658 ;AS/NZS 5000.1; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number cores : One core, two cores,
More informationHaving the widest range of cable glands products to meet every kind of requirement for use in marine, Industrial and Non(Industrial)Areas.
Aftec is a leading manufacturer of cable glands,cable Connectors and associated accessories, used extensively for power control, lighting and instrumentation cable application in connection with IEC and
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationThermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L
Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry
More informationEx eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE
Ex eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE To easily accommodate your unique application requirements and maintain compliance with certification
More informationGlobal Cable Gland Solutions
Global Cable Gland Solutions Global Cable Gland Solutions For more than 100 years, companies have come to rely on Cooper Crouse-Hinds for value they can trust to grow their business. Our comprehensive
More informationK Series 3 Way Direct Acting Balanced Poppet Solenoid Valve
Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS
More informationCable Glands - American Series - NEC/IEC
Cable Glands - 103 American Series - NEC/IEC 104 Cable Glands Explosion Proof & General Purpose Cable Gland/Connector Type 711 1 2 3 1 Unique Rear Sealing System This arrangement offers IP66, IP67, IP68
More informationAs one of the leaders in cable management systems industry, MASEICO maintained the unique success by producing its developed range of cable glands.
Introduction As one of the leaders in cable management systems industry, MASEICO maintained the unique success by producing its developed range of cable glands. MASEICO cable glands were designed and manufactured
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationIt s time to get connected with
It s time to get connected with The essence of quality NEW See pag e6 PRATLEY products and P NUTS are distributed exclusively in the UK by: Cable Connectors Ltd Product Brochure Aluminium Alloy (Corrosion
More informationAS/NZS :2013. Plugs and socket-outlets for household and similar purposes AS/NZS :2013
AS/NZS 60884.1:2013 Australian/New Zealand Standard Plugs and socket-outlets for household and similar purposes Part 1: General requirements (IEC 60884-1, Ed.3.1 (2006) MOD) AS/NZS 60884.1:2013 AS/NZS
More informationTRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom
TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom Annex to IECEx Certificate of Conformity Equipment Range: The design variants covered are either: a) Complete
More informationAustralian/New Zealand Standard
AS/NZS 3112:2011 AS/NZS 3112:2011 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets AS/NZS 3112:2011 This Joint Australian/New Zealand Standard was prepared by Joint
More informationAS/NZS 3131:2001 AS/NZS
AS/NZS 3131:2015 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets for stationary appliances Superseding AS/NZS 3131:2001 AS/NZS 3131:2015 AS/NZS 3131:2015 This joint
More informationGas-actuated temperature switch Stainless steel switch enclosure Model TWG
Mechatronic Electrical temperature measurement Gas-actuated temperature switch Stainless steel switch enclosure Model TWG WIKA data sheet TV 31.60 Process Performance Series Applications Temperature monitoring
More informationMini temperature switch Stainless steel switch enclosure Model TXS
Mechatronic temperature measurement Mini temperature switch Stainless steel switch enclosure Model TXS WIKA data sheet TV 31.70 Process Mini Series Applications Temperature monitoring and control of processes
More informationILED Dorado. User Manual
10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...
More informationLUGS GLANDS & LUGS GLANDS A2/BW/CW. TAN TECK SENG Electric Co. (Pte) Ltd 2009/2010
2009/2010 GLANDS & LUGS GLANDS A2 Industrial Gland BW Armoured Gland CW Armoured Gland A2/BW/CW LUGS Project Title Ping Yi Secondary School Linear Factory Draycott Park Condominium Sentosa Monorail Spring
More informationGOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS
More informationResistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L
Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical
More informationSegurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions
Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...
More informationSOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4
SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4 U 2 1 3 3/2 Series 327 FEATURES The valves are certified according to IEC 61508 Functional Safety data and have SIL-3 capability
More informationIECEx Certificate of Conformity
T ~ IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationcable_glands_en.qxp :25 Uhr Seite 3 cable glands
cable glands 2 The main focus of our business is on the safety of our customers during their day-to-day work. For over 80 years now, we ve been leading the way in the explosion protection sector in achieving
More informationGOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS
More informationACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS
Z A H LO C ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS BASIC CATALOG NUMBERS HKHPBMMSS1 HKHPBMMTC1 HKHPBILLMM1 HKHPBMMMR1 HKHPBMMMB1 HKHPBMMMG1 HKHDBLPBMMGR1 HKHPBPMTMR1 HKHPBPMTMB1 HKHPBPMTMG1 HKHPBTMTMR1
More informationTBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22
Hazardous Area Electrical Equipment TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBKS/CBKS Information Page Ask
More informationJBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped
Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For
More informationSpring loaded resistance thermometer
Spring loaded resistance thermometer THERMOWELL & REPLACEABLE INSERT C200-201-204-205-260-262 CONFIGURATIONS Ex ia RTD Product series PT100RI/WI C200 C201 C204 C205 C260 C262 2 Features assembly The industrial
More informationHazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index
Hazardous Area Electrical Equipment Made TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBKF/CBKF Information Page
More informationTB range of empty sheet metal enclosures. R S Sindair K~'
of Conform ity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certitication Scheme tor Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: Applicant:
More informationINTERNATIONAL METAL ENGINEERING
INSTRUMENT ENCLOSURES, JUNCTION BOXES, STOPPING PLUGS, TEMPERATURE ASSEMBLIES AND A WIDE RANGE OF INDICATORS, TRANSMITTERS AND BATCH CONTROLLERS FM, CSA, ATEX, IECEx CERTIFIED OCTOBER 2015 INTERNATIONAL
More informationPrice List "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four
Price List HSN Code : 8544 w.e.f. : 01.06.2018 "NATIONAL" PVC FLEXIBLE CABLE WITH COPPER CONDUCTOR SINGLE CORE 1.1 KV CONFORMING TO IS:694/2010. "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING
More informationExplosion protected terminal boxes type, GHG 72.
1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55
More informationTWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY.
TWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY. Ex cable glands from CMP and R. STAHL. PARTNERSHIP WITH CMP STRENGTHENS POSITION OF R. STAHL AS EX-SYSTEM SUPPLIER The ability to globally deploy
More informationZone 1 Linear Range - Installation Guide
Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text
More informationAustralian/New Zealand Standard
AS/NZS 3131 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets for stationary appliances This Joint Australian/New Zealand Standard was prepared by Joint Technical
More informationSynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
SynergEX Panelboards Panelboards for Hazardous Locations Installation & Maintenance Information IF 1659 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CAUTION Read these operating instructions and all other
More informationCable Glands for Hazardous Areas
Cable Glands for Hazardous Areas Cable Glands for Hazardous Areas Ex d Ex e 2 Registered HUMMEL AG For over 60 years HUMMEL AG has provided outstanding EXIOS should be the new choice of specification solutions
More informationSolenoid coils VACF Type codes
Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,
More informationSolutions Ex d IIB+H2, Aluminum and Stainless Steel
Features Assembly examples Enclosures manufactured from copper-free aluminum or AISI 316L stainless steel Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d IIB+H2 and Ex tb More than 40 enclosure
More informationP High Voltage Catalogue Cables Australia Powering your Project
P +61 8 9367 8978 www.cablesaustralia.com.au High Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD HIGH VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated
More informationLinear fittings EVDL LED fitting - zones 21, & 22
ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield
More informationGlobal Cable Gland Solutions
Global Cable Solutions Global Cable Solutions For more than 100 years, companies have come to rely on Cooper Crouse-Hinds for value they can trust to grow their business. Our comprehensive offering of
More informationHYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY
HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY Technical Data Electrical Thermal Trademark Type designation Specification Application
More informationILED Aquarius Illuminated Windsock. User Manual
Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...
More informationAS/NZS :2013. Wheelchairs AS/NZS :2013. Australian/New Zealand Standard
AS/NZS 3695.2:2013 Australian/New Zealand Standard Wheelchairs Part 2: Requirements and test methods for electrically powered wheelchairs (including mobility scooters) Superseding AS 3695 1992 AS/NZS 3695.2:2013
More informationTechnical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications
Technical Datasheet - Flameproof Pressure Switch Key Features Compact and rugged design. Weatherproof IP66/NEMA 4. ATEX Flameproof CENELEC EEx d IIC option. ATEX Intrinsically Safe ATEX Ex ia IIC option.
More informationHTSB system System overview
HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.
More information