DECLARATION OF PERFORMANCE. No EN

Size: px
Start display at page:

Download "DECLARATION OF PERFORMANCE. No EN"

Transcription

1 DECLARATION OF PERFORMANCE No EN 1. Unique identification code of the product-type: fischer FIS GREEN 2. Intended use/es: Product Metal injection anchors for use in masonry Intended use/es For fixing and/or supporting to masonry, structural elements (which contributes to the stability of the works) or heavy units 3. Manufacturer: fischerwerke GmbH & Co. KG, Otto-Hahn-Straße 15, Denzlingen, Germany 4. Authorised representative: System/s of AVCP: 1 6a. Harmonised standard: --- Notified body/ies: --- 6b. European Assessment Document: ETAG 029; European Technical Assessment: ETA-14/0471; Technical Assessment Body: DIBt Notified body/ies: 1343 MPA Darmstadt 7. Declared performance/s: Mechanical resistance and stability (BWR 1) Essential characteristic Performance Characteristic resistance for tension and shear loads See Annex C 1 to C 3 Characteristic resistance for bending moments See Annex C 4 Displacements under shear and tension loads See Annex C 4 Reduction Factor for job site tests (β-factor) See Annex C 4 Edge distances and spacing See Annex C 5 Safety in case of fire (BWR 2) Essential characteristic Reaction to fire Resistance to fire Performance Anchorages satisfy requirements for Class A1 No performance determined (NPD) 8. Appropriate Technical Documentation and/or Specific Technical Documentation: --- The performance of the product identified above is in conformity with the set of declared performance/s. This declaration of performance is issued, in accordance with Regulation (EU) No 305/2011, under the sole responsibility of the manufacturer identified above. Signed for and on behalf of the manufacturer by: Andreas Bucher, Dipl.-Ing. Wolfgang Hengesbach, Dipl.-Ing., Dipl.-Wirtsch.-Ing. Tumlingen,

2 Page 18 of European Technical Assessment ETA-14/0471 of 3 February 2015 DIBt Table C1.1; Characteristic values of resistance to tension loads and to shear loads for solid bricks Bricl< No. Density p [l<g/dm'] Compressive strength fb [N/mm^] SIeeve FIS H...K Anchor size or screw size in internal threaded anchor Effective anchorage depth tief,min flef.max Characteristic resistance [kn] 24/40X 50/80 C d/d wav d/d w/w \/ VRk All categories M M (1.5) () () () () () () 4.0 (2.5) () pä1,8 fbä20 (fbälo) without M ,5 (3,0) 4,5 (3,0) 6,0 M ,0 (4,5) 6.0 (4.5) (4.0) M (11,0) 12,0 (11,0) 12,0 (8,5) M ,0 (3,0) 4,0 (3,0) M ,0(5,0) 7,0 (5,0) 5,5 (4,0) M ,0 (7.0) 10,0 (7,0) 12,0(11.5) FIS E M6/8, FISEM10/M ,0 (4,5) 6,0 (4,5) 4,0 () M () () () () M () () 4,0 (3,0) P S 1.8 fb>20 (fbä10) without MIO (2,0) 3.0 () MIO (3,0) 4.0 (3,0) M ,0 (9,0) 12,0 (9,0) M ,0 (2,0) 3,0 (2.0) 5.5 (4,0) 2 M ,5 (3,0) 4,5 (3,0) M ,0 (9.0) 12,0 (9,0) 7.0 (5.0) V< FIS E M6/8, FISEM10/M ,0 () 4,0 (2.5) 4,0 (3.0) 12x85 M6/ ,0 (5,5) 4,5 (3,0) 4,5 (3,0) 16x85 M8/M ,5 (3,5) 3,0 (2,0) 3 P fba20 (fb^lo) 20x ,0(9,5) 8,0 (5,5) 16x130 M8/M10 18x130/200 MI O/Ml (3,0) 2.5 (2.0) 20x130 22x130/200 M (6,0) 5,0 (3,5) 5,5 (3.5) M P ^ 1.8 fbä 20 without M ,0 4.0 M ,0 5.5 M ,0 For design according to ETAG 029, Annex C: Vri = Vpk.b = ^ = Vr^ s flscher Injectionsystem FIS GREEN for masonry Characteristic values of resistance to tension load and shear load, part 1 Annex C1 Z /14

3 Page 19 of European Technical Assessment ETA-14/0471 of 3 February 2015 DIßt Tabie C1.2: Characteristic values of resistance to tension loads and to shear loads for perforated bricks Brick No. Density p [kg/dm^] Compressive strength fb [N/mm^] SIeeve FISH...K Anchor size or screw size In Intemal threaded anchor Effective Characteristic resistance [kn] anchorage depth hef.mln hef.max 24/40X 50/80 C d/d w/w d/d w/w \/ VRk All categories - 5 P ä1.4 fbäs 12x85 16x85 20x85 M6/M8 M8/I\/I ,5 2,0-6.;^p P Q.'^aS AI ä0,6 ft,>8 12x85 M6/M x85 M8/M x85 MIO,, x130 18x130/200 20x130 22x130/200 M8/M10 M10/M12 M ,5 (2.0) 5,5 (3,5) 4,5 () 2,0 (1.2) 3,5 (2,0) (1.5) 4,5 (2.5) 8.0 (5,5) 7,5 (4,5) 8,0 (5,5) 7,5 (4,5) 12x85 M6/M x85 M8/M ,0 20x85 M12,M x130 18x130/200 M8/M10 M10/M ,0 20x130 22x130/200 M x x85 M6, M , ,0 16x85 M8.M ,5 P ^ fbä10 20x85 M12, M ,0 16x130 M8/M ,5 5,5 18x130/200 M10/M x130 22x130/200 M16 For design according 1o ETAG 029, Annex C: Nrk = Nrk.p = NRK.b = NRk,s For design according to ETAG 029, Annex C: Vrk = VRk,b = VRk,c = Vri,« ,5 2,0 6,0 flscher Injectionsystem FIS GREEN for masonry Characteristic values of resistance to tension load and shear load, part 2 Annex C 2 Z /14

4 Page 20 of European Technical Assessment ETA-14/0471 of 3 February 2015 DIßt Table C1.3: Characteristic values of resistance to tension loads and shear loads for aerated concrete Density p [kg/dm'] Effective anchorage depth Characteristic resistance [kn] NRk^' \/ VRk Brick No. Compressive strength ft [N/mm^] SIeeve FIS H...K Anchor size or screw size in internal threaded anchor hef.min hef.max 24/40 C 50/80 C d/d w/w d/d w/w All categories p >350 fb^2 M ,2 1.2 M , ,0 1.5 without MIO , ,0 M ,0 2,0 M , ,2 ff" M ,0 1.5 M ,0 p 2:500 fbs4 without MIO ,0 2, M ,0 2.5 M ,0 p a650 fbä6 M ,0 2,0 M ,5 2.5 without MIO ,0 3,0 4,0 3,0 M ,0 3,0 4,0 3,0 2.5 M ,0 3, ,0 2,0 For design according to ETAG 029, Annex C: Nr^ = NRk,p = Npk.b = Npk.s For design according to ETAG 029, Annex C: Vpk = VRk b= VRk.c = VRk,s fischer Injectionsystem FIS GREEN for masonry Characteristic values of resistance to tension loads and shear loads for aerated concrete, part 3 Annex C 3 Z /14

5 Page 21 of European Technical Assessment ETA-14/0471 of 3 Febmary 2015 DIßt Table C2: Characteristic bending moments Size M6 MS MIO M12 M16 Zinc-plated Property 5.8 [Nm] Charac steel class 8.8 [Nm] teristic Stainless Property 50 [Nm] bending steel A4 class 70 [Nm] moment High 50 [Nm] corrosionresistant Property MRk,s 70^' [Nm] class Steel C 80 [Nm] 'fuk =700 N/mm^; fy^ = 560 N/mm^ Table C3: Displacements under tension load and shear load N Sno 8nx IkN] Solid bricks'' 1,32 2,64 NRk t\k Perforated bricks"'' 1,0 2,0 Aerated concrete 1,0 2,0 V 5vo 5v» [kn] 1,2 1, ,85 1,4 2,93 4,4 Blick No.;1;2;3;4 ^'Brick No.:5;6:7;8 Table C4: ß- factor for job site tests according to ETAG 029, Annex B Brick Size ß- Factor No. Temp 24 C/40 C Temp 50 C/80 C 1 2 d/d w/w d/d wav M6;M8 0,8 0,48 0,80 0,48 Mi 2x200 0,78 0,78 0,78 0,78 Other sizes 0,84 0,84 0,84 0,84 Other sizes 0,84 0,84 0,81 0,81 M8x200 0,55 0,55 0,55 0,54 M6x50 0,84 0,51 0,84 0,51 3 All sizes 0,84 0,84 0,51 0,5 4 Other sizes 0,84 0,84 0,84 0,84 M6x50 0,84 0,51 0,84 0,51 5 All sizes 0,71 0,71 0,43 0,43 6 All sizes 0,84 0,84 0,51 0,50 7 Other sizes 0,84 0,84 0,51 0,51 20x130,20x200 0,67 0,67 0,41 0,4 8 All sizes 0,84 0,84 0,51 0,50 9 All sizes 1,0 0,79 1,0 0,79 fischer Injectionsystem FIS GREEN for masonry Characteristic bending moments; displacements; ß- factors for job site tests Annex C 4 Z /14

6 Page 22 of European Technical Assessment ETA-14/0471 of 3 Febmary 2015 DIBt Table C5: Edge distance and spacing (instailation with and without sieeves) Dlrectlon to bed joint 1 Min. thickness Brick No. hef Cirin Smin Scr Smin Scr of the masonry members o a all sizes o co + 6 all sizes all sizes all sizes all sizes ) o O' I 'O o.1=: :q q: Smin II = Minimum spacing anchor group parallel to bed Joint Smin-*- = Minimum spacing anchor group vertical to bed joint Scrii = Characteristic spacing anchor group parallel to bed joint Scr-*- = Characteristic spacing anchor group vertical to bed joint Ccr = Cmin = Edge dlstance group of 2 anchors: NRk =2x Nr^ ;VRk =2x Vrk group of 4 anchors: NRk =4x Nrk ;Vr^Mx Vrk fischer Injectionsystem FIS GREEN for masonry Edge distance and spacing Annex C 5 Z /14

Declaration of Performance

Declaration of Performance Declaration of Performance 1343-CPR- 530-8/01.15 1. Unique identification code of the product-type: Injection anchors ungo IT-SP/IT-SPE Plus, IT-SP Winter for use in masonry 2. anufacturer: ungo Befestigungstechnik

More information

HSA Carbon steel HSA-F Carbon steel hot-dipped galvanised with DIN 125 washer. HSA-R Stainless steel A4. HSA-BW Carbon steel with DIN 9021 washer

HSA Carbon steel HSA-F Carbon steel hot-dipped galvanised with DIN 125 washer. HSA-R Stainless steel A4. HSA-BW Carbon steel with DIN 9021 washer HSA stud anchor Anchor version Benefits HSA Carbon steel HSA-F Carbon steel hot-dipped galvanised with DIN 125 washer HSA-R Stainless steel A4 small edge distance and spacing three different embedment

More information

FEATURES APPLICATIONS. Technical data sheet VAS - VAS THREADED ROD. VAS Threaded Rod for use with the VAC Capsule System. UK-DoP-e13/0937, ETA-13/0937

FEATURES APPLICATIONS. Technical data sheet VAS - VAS THREADED ROD. VAS Threaded Rod for use with the VAC Capsule System. UK-DoP-e13/0937, ETA-13/0937 - THREADED ROD Rod for use with the VAC Capsule System FEATURES UK-DoP-e130937, ETA-130937 Material Material: Carbon steel, zinc plated and blue passivated. Range: M8 - M30 APPLICATIONS Support Non-cracked

More information

Declaration of Performance (DoP)

Declaration of Performance (DoP) No. DoP 1 1/3 1. 2. Unique identification code of the product-type SPAX Type, batch or serial number or any other element allowing identification of the construction product as required pursuant to Article

More information

European Technical Assessment ETA-13/0900 of 10/04/2014

European Technical Assessment ETA-13/0900 of 10/04/2014 ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011

More information

Assessment Report. Stanley Black & Decker Deutschland GmbH Richard-Klinger-Str Idstein

Assessment Report. Stanley Black & Decker Deutschland GmbH Richard-Klinger-Str Idstein Assessment Report Project 21827 condensed version Assessment of resistance under fire exposure of the Injection System AC200+ Employer Stanley Black & Decker Deutschland GmbH Richard-Klinger-Str.11 65510

More information

fischer Bolt anchor FAZ II

fischer Bolt anchor FAZ II fischer Bolt anchor FAZ II The power anchor for highest demands NEW Bolt anchor FAZ II For highest demands Powerful and flexible The distinctive edge holds the expansion clip in position even with reinforcement

More information

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE DECLARATION OF PERFORMANCE No. DoP Trimoterm Power T, 26.04.2018_en 1. Unique identification code of the product-type: Trimoterm Power T, type FTV, FTV H, FTV HL, SNV 2. Intended use/es: Self-supporting

More information

EJOT Multifix VSF. EJOT Baubefestigungen GmbH In der Stockwiese BAD LAASPHE Germany

EJOT Multifix VSF. EJOT Baubefestigungen GmbH In der Stockwiese BAD LAASPHE Germany Member of Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 www.eota.eu Tél. : (3 01 64 68 82 82 Fax : (3 01 60 05 70 37 European Technical

More information

fischer Bolt anchor FAZ II The power anchor for highest demands.

fischer Bolt anchor FAZ II The power anchor for highest demands. fischer Bolt anchor FAZ II The power anchor for highest demands. Bolt anchor FAZ II For highest demands. Powerful and flexible. The distinctive holds the expansion clip in position even with reinforcement

More information

Declaration of Performance DoP MOVISE-en

Declaration of Performance DoP MOVISE-en Declaration of Performance DoP MOVISE-en 1. Product type: Vinyleter bonded anchor MOVISE 2. Identification: MOVISE300 Vinyleter bonded anchor 300 ml MOVISE410 Vinyleter bonded anchor 410 ml 3. Intended

More information

Zykon Bolt anchor FZA, zinc-plated steel. Zykon Internallythreaded. FZA-I, zinc-plated steel Zykon Through anchor FZA-D, zinc-plated steel

Zykon Bolt anchor FZA, zinc-plated steel. Zykon Internallythreaded. FZA-I, zinc-plated steel Zykon Through anchor FZA-D, zinc-plated steel HIGH PERFORMANCE STEEL ANCHORS 129 The powerful and safe undercut anchor for cracked concrete. OVERVIEW DESCRIPTION Zykon Bolt anchor FZA, zinc-plated steel Zykon Internallythreaded anchor FZA-I, zinc-plated

More information

General Information. Installation Information Design Information Material Information Ordering Information

General Information. Installation Information Design Information Material Information Ordering Information General Information General Information PTBPRO Throughbolt ProDUCT DESCRIPTION The PTBPRO is a fully threaded, torque controlled, wedge expansion anchor which is designed for consistent performance in

More information

European Technical Assessment ETA-09/0355 of

European Technical Assessment ETA-09/0355 of ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011 of

More information

EF500R CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM

EF500R CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM EF500R CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM [Seismic C2] APPROVAL DOC TDS MSDS Technical Data Sheet SEP 2019 For Install Support techadvice@allfasteners.com.au For Specification Support engineering@allfasteners.com.au

More information

Declaration of Performance DoP No. 008

Declaration of Performance DoP No. 008 1. Unique identification code of product type: Autoclaved Aerated Concrete Blocks (see Tables 1 to 3 below). 2. Type, batch or serial number or any other element allowing identification of the construction

More information

(English language translation, the original version is in French language) Upat Bolt

(English language translation, the original version is in French language) Upat Bolt Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

HIGH PERFORMANCE STEEL ANCHORS

HIGH PERFORMANCE STEEL ANCHORS Throughbolt zinc plated, -HD Throughbolt hot dip galvanized anchor name BASE MATERIALS: concrete, stone non-cracked concrete PRODUCT CODE -10080/20 -HD-06050/10 zinc coat type thread diameter length FEATURES:

More information

COMPFIRE SCFT-FP_20_55_ November 2010 Fin Plate Connection to Square Concrete-Filled Tube Test Result

COMPFIRE SCFT-FP_20_55_ November 2010 Fin Plate Connection to Square Concrete-Filled Tube Test Result Reaction Frame Macalloy Bars Camera 3 Support Beam α Oven Bar Camera 2 Link Bar Camera 1 Tested Connection Jack Bar Electrical Furnace Reaction Frame Load Jack 16 November 2010 1 Oven Bar Link Bar View

More information

Blue-Tip Screwbolt BT

Blue-Tip Screwbolt BT Blue Tip Screwbolt hex head, white zinc plating BT Blue Tip Screwbolt hot dipped galvanised, white zinc plating BT-HDG Blue Tip Screwbolt hex head, stainless steel BT-SS Blue Tip Screwbolt countersunk

More information

Trutek TCM 385RE - Pure Epoxy 3:1

Trutek TCM 385RE - Pure Epoxy 3:1 Features and Benefits Version 23/12/2013 High bond strength with High load resistance Used with all grades of threaded rod and rebar in accordance with TR029 Ideal for deep embedment installations Used

More information

COMPFIRE. Reaction Frame. Camera 3. Macalloy Bars. Camera 2. Link Bar. Support Beam. Oven Bar. Camera 1. Jack Bar.

COMPFIRE. Reaction Frame. Camera 3. Macalloy Bars. Camera 2. Link Bar. Support Beam. Oven Bar. Camera 1. Jack Bar. Reaction Frame Macalloy Bars Camera 3 Support Beam α Oven Bar Camera 2 Link Bar Camera 1 Tested Connection Jack Bar Electrical Furnace Reaction Frame Load Jack 22 September 2010 1 Oven Bar Link Bar View

More information

DECLARATION OF PERFORMANCE DoP N EN

DECLARATION OF PERFORMANCE DoP N EN CONSTRUCTION PRODUCTS REGULATION (EU) 305/2011 DECLARATION OF PERFORMANCE DoP N 006-01-EN 1. Unique identification code of the product type: panic device according to DIN EN 1125:2008-04 1309-CPD-0194

More information

Centre Scientifique et Technique du Bâtiment 4, avenue du Recteur Poincaré F PARIS Cedex 16 Tél. : (33) Fax : (33)

Centre Scientifique et Technique du Bâtiment 4, avenue du Recteur Poincaré F PARIS Cedex 16 Tél. : (33) Fax : (33) Centre Scientifique et Technique du Bâtiment 4, avenue du Recteur Poincaré F-75782 PARIS Cedex 16 Tél. : (33) 01 40 50 28 28 Fax : (33) 01 45 25 61 51 Autorisé et notifié conformément à l article 10 de

More information

VF22PRO CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM

VF22PRO CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM VF22PRO CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM APPROVAL DOC TDS MSDS Technical Data Sheet SEP 2016 For Install Support techadvice@allfasteners.com.au For Specification Support engineering@allfasteners.com.au

More information

highlights Double tube linear actuators

highlights Double tube linear actuators highlights GN 491 with right or left hand thread, single slider 3 Type R1 Right hand thread, single shaft end R2* Right hand thread, two shaft ends L1* Left hand thread, single shaft end L2* Left hand

More information

Polyfixer PSF. Features and Benefits Version: 14/04/2015

Polyfixer PSF. Features and Benefits Version: 14/04/2015 Features and Benefits Version: 14/04/2015 Good bond strength with High load resistance Used with all grades of threaded rod Used in concrete and masonry Fast gelling and curing Used in dry and wet conditions

More information

The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. Zinc-plated steel Stainless steel Hot-dip galvanised steel

The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. Zinc-plated steel Stainless steel Hot-dip galvanised steel The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS APPROVALS Zinc-plated steel Stainless steel Hot-dip galvanised steel BUILDING MATERIALS Approved for: Concrete C20/25 to C50/60,

More information

fischer Highbond FHB II

fischer Highbond FHB II fischer Highbond FHB II The first compound anchor suitable for tensile zones approved worldwide for resin capsules and injection systems. New capsule can be loaded super fast! The multifunctional bonded

More information

Anchor bolt FAZ II Millionfold proven anchor bolt and the strongest in its class.

Anchor bolt FAZ II Millionfold proven anchor bolt and the strongest in its class. 118 FAZ II Millionfold proven bolt and the strongest in its class. OVERVIEW FAZ II, zinc-plated steel FAZ II A4, stainless steel of the corrosion resistance class III, e.g. A4 FAZ II C, highly corrosion-resistant

More information

DICHIARAZIONE DI PRESTAZIONE No. HSL-3, HSL-3-R_B-1109-CPR-0002

DICHIARAZIONE DI PRESTAZIONE No. HSL-3, HSL-3-R_B-1109-CPR-0002 IT DICHIARAZIONE DI PRESTAZIONE No. HSL-3, HSL-3-R_B-1109-CPR-0002 1. Codice di identificazione unico del tipo di prodotto: Hilti HSL-3, HSL-3-R 2. Utilizzo/i previsto/i: Prodotto Tasselli metallici da

More information

Pure110-PRO. System Components. Grades. General Information. Installation Information

Pure110-PRO. System Components. Grades. General Information. Installation Information General Information SECTION CONTENTS Pure11PRO General Information Installation Information Epoxy Injection Adhesive Anchoring System Design Information ProDUCT DESCRIPTION The Pure11PRO is our latest

More information

Bolt FBN The heavyweight.

Bolt FBN The heavyweight. 120 The heavyweight. OVERVIEW II, A4, stainless steel A4 Approved for: Non-cracked concrete C20/25 to C50/60 Also suitable for: Concrete C12/15 Natural stone with dense structure -GS (with large washer),

More information

fischer Superbond System

fischer Superbond System fischer Superbond System The universal solution for cracked concrete. ETA-12/0258 fischer Superbond System FSB: The universal solution for concrete. Advantages at a glance Variable of 60 600 mm Free choice

More information

POWER-STUD. Mechanical Anchors GENERAL INFORMATION SECTION CONTENTS. Stainless Steel Wedge Expansion Anchor

POWER-STUD. Mechanical Anchors GENERAL INFORMATION SECTION CONTENTS. Stainless Steel Wedge Expansion Anchor General Information Mechanical s GENERAL INFORMATION POWER-STUD Stainless Steel Wedge Expansion PRODUCT DESCRIPTION The Power-Stud anchor, is a fully threaded, torque-controlled, wedge expansion anchor.

More information

System Components. Grades. General Information Installation Information

System Components. Grades. General Information Installation Information General Information General Information SECTION CONTENTS Pure15PRO General Information Installation Information Epoxy Injection Adhesive Anchoring System Design Information ProDUCT DESCRIPTION The Pure15PRO

More information

T.I. Midwood Co Ltd Green Lane Wardle Nantwich Cheshire CW5 6BJ T: +44 (0) F: +44 (0)

T.I. Midwood Co Ltd Green Lane Wardle Nantwich Cheshire CW5 6BJ T: +44 (0) F: +44 (0) Features and Benefits Version 05/07/2014 High bond strength with High load resistance Used with all grades of threaded rod and rebar in accordance with TR029 Used in non-cracked and cracked concrete Fast

More information

BUFFALO - XP. A StongFast Product. For more information call Or log on to

BUFFALO - XP. A StongFast Product. For more information call Or log on to Features and Benefits Version: 25/09/2017 Good bond strength with High load resistance Used with all grades of threaded rod Used in concrete and masonry Fast gelling and curing Used in dry and wet conditions

More information

Chemical fixing threaded rod

Chemical fixing threaded rod Chemical fixing threaded rod Technical data Type Mx110 M10x130 M12x160 M12x220 M16x190 M16x220 M20x260 d M M10 M12 M12 M16 M16 M20 L 110 130 160 220 190 220 260 t fix (max.) 17 2 36 5 42 67 65 Drill ø

More information

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions!

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions! Rev. 1.8 Operating Manual for Pressure Sensors 97PA-21x-xxx page 1 of 6 Operating Manual Pressure Sensors Article numbers: 97PA-21G-10 97PA-21G-50 97PA-21Y-5 97PA-21Y-25 97PA-21Y-160 97PA-21Y-400 NOTE

More information

Designated according to Article 29 of Regulation (EU) No 305/2011

Designated according to Article 29 of Regulation (EU) No 305/2011 British Board of Agrément Bucknalls Lane Watford Herts WD25 9BA Tel: +44 (0) 1923 665300 e-mail: clientservices@bba.star.co.uk website: www.bbacerts.co.uk Designated according to Article 29 of Regulation

More information

MULTI-MONTI -plus THE NEW MULTI-MONTI WITH THE BIG PLUS

MULTI-MONTI -plus THE NEW MULTI-MONTI WITH THE BIG PLUS MULTI-MONTI -plus THE NEW MULTI-MONTI WITH THE BIG PLUS MMS-plus MULTI-MONTI -plus PRODUCT INFORMATION New Standard: hexagon head with combined washer Optimized concrete thread for higher efficiency More

More information

fischer bonded anchor systems for cracked concrete Three systems one goal the maximum performance

fischer bonded anchor systems for cracked concrete Three systems one goal the maximum performance fischer bonded anchor systems for cracked concrete Three systems one goal the maximum performance fischer composite anchor systems for cracked concrete at a glance. Page 3 The premium solution for cracked

More information

Tested fasteners for passive structural fire prevention

Tested fasteners for passive structural fire prevention Resistance to fire Tested fasteners for passive structural fire prevention Tested according to the international standard temperature curve MFPA Leipzig GmbH Tested according to the international standard

More information

(English language translation, the original version is in French language) FM 753

(English language translation, the original version is in French language) FM 753 Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

EJOT ECOset HTK 2G Cordless Installation System to Secure Roofing Membrane on Flat Roofs. The Quality Connection

EJOT ECOset HTK 2G Cordless Installation System to Secure Roofing Membrane on Flat Roofs. The Quality Connection EJOT ECOset HTK 2G Cordless Instaation System to Secure Roofing Membrane on Flat Roofs The Quality Connection www.ejot.co.uk Instaation System ECOset HTK 2G Fastening now without power cable! With the

More information

(English language translation, the original version is in French language) PFG expansion bolt type LB, ES and SB

(English language translation, the original version is in French language) PFG expansion bolt type LB, ES and SB Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

MN Press Force Calibration Sensor

MN Press Force Calibration Sensor Force Sensor for Measuring Large Compression Force Piezoelectric sensor for measuring quasistatic and dynamic compression forces in the meganewton range. This series of calibration sensors is designed

More information

Hilti HST Submission Folder

Hilti HST Submission Folder Submission folder Hilti HST Submission Folder Sample Submission and Approval Form 2-3 Product Information 4-5 Technical Data 6-10 Method Statement 11 Test Reports according to BS5080 HST HST-R 12-36 37-73

More information

HW-B50H HW-W50L HW-W50LU

HW-B50H HW-W50L HW-W50LU Product Content 1 Coverage and Terminology... 4 1.1 Design Standards... 4 1.2 Load Criteria... 5 1.3 Definition of Terms... 6 1.3.1 Flood Barrier... 6 1.3.2 Flood Protection Walls... 7 1.3.3 Flood Protection

More information

DIN EN : (E)

DIN EN : (E) DIN EN 13480-3:2017-12 (E) Metallic industrial piping - Part 3: Design and calculation Contents Page European foreword... 10 1 Scope... 12 2 Normative references... 12 3 Terms, definitions, symbols and

More information

VERSIONS. zinc-plated steel stainless steel highly corrosion-resistant steel BUILDING MATERIALS

VERSIONS. zinc-plated steel stainless steel highly corrosion-resistant steel BUILDING MATERIALS Efficient fixing for cracked concrete VERSIONS APPROVALS zinc-plated steel stainless steel highly corrosion-resistant steel BUILDING MATERIALS Approved for: Concrete C20/25 to C50/60, cracked Concrete

More information

JF375E JF300E JMN150E. Load Time T load (hrs) Range Data. Maximum Fixture Thickness. Drill Hole Diam.

JF375E JF300E JMN150E. Load Time T load (hrs) Range Data. Maximum Fixture Thickness. Drill Hole Diam. Product Information The Epoxy 2 Part injection resin is suitable for use in solid concrete, solid brickwork and natural stone. It can be used for installing threaded studs, rebar or internal threaded sockets.

More information

Tillers Motor hoes (combustion engine powered)

Tillers Motor hoes (combustion engine powered) Compliance Guide Rev.2.1, Edition 04/2018 This guide is intended to help market surveillance authorities with the checking of conformity of combustion engine powered brush-cutters and grass trimmers in

More information

fischer Hammerset anchor EA II

fischer Hammerset anchor EA II Now with reduced embedment depth Now with reduced embedment depth fischer Hammerset anchor EA II The mounting-friendly hammerset anchor for fast and secure fixing. ETA-07/0135 ETAG 001-4 Option 7 for non-cracked

More information

DECLARATION OF PERFORMANCES N TOLE 01A EN

DECLARATION OF PERFORMANCES N TOLE 01A EN LR ETANCO SAS Parc les Erables Bât 1 66 route de Sartrouville BP 49 78231 LE PECQ Cedex France Tel. : +33 (0)1 34 80 52 00 Fax : +33 (0)1 30 71 01 89 E-mail : commercial.france@etanco.fr Web : www.etanco.eu

More information

TECHNICAL DATASHEET SITA ACCIAIO CE 1 steel wedge anchor for cracked and non-cracked concrete

TECHNICAL DATASHEET SITA ACCIAIO CE 1 steel wedge anchor for cracked and non-cracked concrete C.so Savona 22,29 Villastellone (TO), Italia rev. 01/1 p. 1/ Certiicates ETA-/0076 Approval accoring to ETAG 001- or non-cracke an cracke concrete (Option 1), Fire Resistance 0 min Use certiie use non-cracke

More information

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY THE UNITED KINGDOM TYPE APPROVAL AUTHORITY Dear Sir / Madam, Date: 02 November 2015 1. The vehicle component / type described on the attached approval(s) has been tested and meets the requirements of the

More information

The Sika Solution x 600 x 700H / 900H. Class D. Roadway Installation Guidelines p 9-11

The Sika Solution x 600 x 700H / 900H. Class D. Roadway Installation Guidelines p 9-11 The Sika Solution Aluminium Jointing Chamber and Security Access Cover Set Package 1200 x 600 x 700H / 900H Class D Contents: Assembly Instructions p 2-8 Roadway Installation Guidelines p 9-11 Sika Technology

More information

Technical Data MM Channel

Technical Data MM Channel Technical Data MM Channel The enclosed pages are taken from the Installation Systems Catalogue 2015 for additional information please visit the technical library at www.hilti.co.uk or call our Technical

More information

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031 MATERIALPRÜFUNGSAMT NORDRHEI N - WESTFALEN EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031 In compliance with the Directive 89/106/EEC of the Council of European Communities of 21 December 1988 on the approximation

More information

Manufacturer: Address: ZIP Code: City: Country: VAT #: Signatory, Name: Signatory, Title: Phone: Fax: WWW: Head of Engineering:

Manufacturer: Address: ZIP Code: City: Country: VAT #: Signatory, Name: Signatory, Title: Phone: Fax:   WWW: Head of Engineering: CERTIFICATION APPLICATION Reciprocating internal combustion engines Certificate No.: EX Exhaust emission measurement - Part 1: Test-bed measurement of gaseous and particulate exhaust emissions Ref.: ISO

More information

AZAM TECHINICAL DATASHEET ZA-CA ZA-TO ZA-TL ZA-AR ZA-PR ZA-ES ZA-GA ZA-AF ZA-GF APPLICATION EXAMPLES

AZAM TECHINICAL DATASHEET ZA-CA ZA-TO ZA-TL ZA-AR ZA-PR ZA-ES ZA-GA ZA-AF ZA-GF APPLICATION EXAMPLES Codes: C, T, ZTXXL, ZTXXC, E, A,G,AF, GF Reference: FT -en Date: 03/02/17 Revision: 3 Page: 1 of 6 ZA-CA ZA-TO ZA-TL ZA-PR ZA-ES ZA-AR ZA-GA ZA-AF ZA-GF CHARACTERISTICS BASE MATERIAL Wings and cone manufactured

More information

CONSULTING Engineering Calculation Sheet. Reference Sheets - Pile Cap Capacity (Generic) Tables XX

CONSULTING Engineering Calculation Sheet. Reference Sheets - Pile Cap Capacity (Generic) Tables XX Job No. Sheet No. E N G I N E E R S Consulting Engineers jxxx 1 Pile Cap Capacity (Generic) Input Characteristic strength of concrete, f cu ( 60N/mm 2 ; HSC N/A) 40N/mm 2 OK Yield strength of longitudinal

More information

Operating Instruction Electro hydraulic workshop presses HPE

Operating Instruction Electro hydraulic workshop presses HPE Operating Instruction Electro hydraulic workshop presses HPE Type Serial number Date Rev. A 116967 07/2011 EC Declaration of Conformity according to EC directive 2006/42/EC on machinery Typ Hier Typenschild

More information

Internal Bracing Design Program Background Information

Internal Bracing Design Program Background Information Internal Bracing Design Program Background Information 2016 by International Masonry Institute All rights reserved. This program is intended as a preliminary design tool for design professionals who are

More information

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill Kiwa Polymer Institut GmbH Quellenstraße 3 D-65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 8464-2-E Testing order: Tests on the coating Wecryl 124

More information

FIXING SYSTEMS. TECHNICAL MANUAL Fixing Systems Terwa reserves the right to make changes to the documentation at any time Page 1

FIXING SYSTEMS. TECHNICAL MANUAL Fixing Systems   Terwa reserves the right to make changes to the documentation at any time Page 1 FIXING SYSTEMS WWW.TERWA.COM Terwa reserves the right to make changes to the documentation at any time Page 1 OVERVIEW FIXING SYSTEMS BSR BSRS BSH BSHF Page 15 Page 16 Page 17 Page 18 BSRF BSRFS BSX HBU

More information

Certificate of constancy of performance

Certificate of constancy of performance 0402-CPR-SC0221-16 In compliance with Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 (the Construction s Regulation or CPR), this certificate applies to the construction

More information

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance 07/2013 Fläkt Woods FIFLO EN 2013.07 2 ZU CLOSED AUF OPEN Fire damper ETPS-EI Contents Operation and Maintenance

More information

HECO-Schrauben GmbH & Co. KG Dr.-Kurt-Steim-Straße 28 D Schramberg Tel.: +49 (0 )74 22 / Fax: +49 (0 )74 22 / Mail:

HECO-Schrauben GmbH & Co. KG Dr.-Kurt-Steim-Straße 28 D Schramberg Tel.: +49 (0 )74 22 / Fax: +49 (0 )74 22 / Mail: HECO-Schrauben GmbH & Co. KG Dr.-Kurt-Steim-Straße 28 D-78713 Schramberg Tel.: +49 (0 )74 22 / 9 89-0 Fax: +49 (0 )74 22 / 9 89-200 Mail: info@heco-schrauben.de www.heco-schrauben.de 43165-07/2007 HECO-TOPIX

More information

Ride-on lawnmowers (combustion engine powered)

Ride-on lawnmowers (combustion engine powered) Compliance Guide Rev.2.3 Edition 04/2018 Ride-on lawnmowers (combustion engine powered) This guide is intended to help market surveillance authorities with the checking of conformity of combustion engine

More information

weinor can hold you the safe, fast way to fix it properly

weinor can hold you the safe, fast way to fix it properly Brackets weinor can hold you the safe, fast way to fix it properly Fixing brackets Folding arm brackets We reserve the right to make technical alterations. December 06 www.weinor.co.uk Brackets 1 www.samsonawnings.co.uk

More information

Operating instructions

Operating instructions Pos: 1.1 /BA_Module/BA_AA Deckblatt/BAAA000001_M001 @ 0\mod_1190623555800_6.doc @ 448 Pos: 1.2 /BA_Module/BA_Seitenumbruch @ 0\mod_1190719383361_0.doc @ 548 en Operating instructions Safety brake FG 220-60

More information

Declaration of Performance

Declaration of Performance Declaration of Certificate No. 0004-CPR-140701 1. Unique ientification of the prouct-type: Lite See table hereuner... 2. Type, batch or serial number or any other element allowing ientification of the

More information

11-Feb-14. VCA job number: CSP Date: 11 February Dear Sirs,

11-Feb-14. VCA job number: CSP Date: 11 February Dear Sirs, VCA job number: CSP286503 Date: 11 February 2014 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC

More information

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation?

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation? A brief guide for identification of non-compliant construction machinery Is this Compactor / Roller compliant with European legislation? Introduction Construction equipment placed on the EU market for

More information

European Technical Approval ETA-10/0198

European Technical Approval ETA-10/0198 European Technical Approval ETA-10/0198 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and

More information

fischer Product Range Direct Fastening

fischer Product Range Direct Fastening fischer Product Range Direct Fastening 2 Direct Fastening Power Drive F35 / F45 Stud Driver PAGE POWER DRIVE F35 STUD DRIVER (8 MM TOOL) 3 8 Power Drive F35 Stud Driver 3 Power Drive F35 Stud Driver Replacements

More information

PARALLEL INDEX DRIVES TP Series

PARALLEL INDEX DRIVES TP Series PARALLEL INDEX DRIVES TP Series Calculations J = moment of inertia Application examples Direct driven belt/chain = M B + M B M B = c a n 2π n x t² M R = µ g R m = M B + M R + (M ST )* M ST = m g R M AN

More information

It may not be used for commercial purposes, unless it is reproduced in its entirety

It may not be used for commercial purposes, unless it is reproduced in its entirety REPORT Assessment of Desso idna X 60-16 with SBR ShockWave in accordance with GAA s Performance and Construction Requirements for Synthetic Turf Pitches Client Desso Sports BV Robert Ramlotstraat 89 Dendermonde

More information

English translation authorized by DIBt Original version in German language

English translation authorized by DIBt Original version in German language Date: Reference: 29/09/2014 I 36-1.14.4-101/13 English translation authorized by DIBt Original version in German language Approval number: Validity Z-14.4-2 from: 29 September 2014 Applicant: Lindapter

More information

Operating instructions

Operating instructions en Operating instructions Safety brake Size 4 51172121 - b 072010 OPERATING INSTRUCTIONS 52210087 List of Contents Page SAFETY DIRECTIONS 3 DESIGN AND FUNCTION4 MAINTENANCE AND EXAMINATION 4 SERVICE /

More information

REBAR CONNECTION SYSTEM

REBAR CONNECTION SYSTEM REBAR CONNECTION SYSTEM WWW.TERWA.COM Terwa reserves the right to make changes to the documentation at any time Page 1 OVERVIEW COUPLERS PSA PSA-PSC PSC-BOLT PSE Page 6 Page 6 Page 8 Page 9 TSE PSA-SS

More information

AS 1252: 2016 K0 8.8 HR Structural Assembly

AS 1252: 2016 K0 8.8 HR Structural Assembly AS 1252: 216 8.8 HR Structural Assembly» AS 1252: 216 8.8 HR replaces dimensional (1996 mechanical)» Fully adhering to the new standard.» Unique Batch head marking. See photo below» Verification Testing

More information

Fire Evaluation. From the original report n Date: 09/12/2013

Fire Evaluation. From the original report n Date: 09/12/2013 Department Structures, Safety and Fire (DSSF) Division Mechanical Resistance and Fire (MRF) Fire Evaluation From the original report n 26048096 Date: 09/12/2013 1 st Issue Product: PURE150-PRO injection

More information

30-Aug-11. VCA job number: CSM Date: 30 August Dear Sirs,

30-Aug-11. VCA job number: CSM Date: 30 August Dear Sirs, VCA job number: CSM241075 Date: 30 August 2011 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC Directive

More information

ANCHORS AND FIXING SYSTEMS EDITION 1

ANCHORS AND FIXING SYSTEMS EDITION 1 ANCHORS AND FIXING SYSTEMS EDITION 1 ANCHORING AND FIXING EXPERTISE DeWALT is a recognised global leader in designing and manufacturing solutions for the construction industry with extensive expertise

More information

ATEX LABELLING FOR MOTORS AND GEAR UNITS

ATEX LABELLING FOR MOTORS AND GEAR UNITS ATEX LABELLING FOR MOTORS AND GEAR UNITS EN ATEX INFORMATION GAS AND DUST COMPLETE DRIVE SOLUTIONS FROM A SINGLE SOURCE RELIABLE n Reliable products n Coordinated components n NORD's own development and

More information

Special Radial piston pumps Type SRK-ATEX

Special Radial piston pumps Type SRK-ATEX Special Radial piston pumps Type SRK-ATEX Features High volumetric efficiency Self-priming and venting Low pulsation Low noise level Design Radial piston pump of modular design With valve controlled pump

More information

30500 MAXXFAST Wall plug UniFast MF50 Plastic Nylon (polyamide) d Art.number d Art.number d Art.number 5MM MM

30500 MAXXFAST Wall plug UniFast MF50 Plastic Nylon (polyamide) d Art.number d Art.number d Art.number 5MM MM Wall plug UniFast d 5 6 7 10 12 L 25 30 30 40 50 60 Drill ø 5 6 7 10 12 Drill depth (min.) 35 40 40 50 60 70 Chipboard screws 2,5-4 3,5-4 4-4,5 4,5-6 6- -10 Pull-out force for wood screw in kn Concrete

More information

VCE Systems Engineering

VCE Systems Engineering VCE Systems Engineering Mechanical formula and Electrotechnology formula and worked examples - speed (m/s) or (ms distance (m) metre time (s) second ) metre per second speed = distance time A car travels

More information

WELMEC External Auxiliary Power Supply of Electrical Energy Meters

WELMEC External Auxiliary Power Supply of Electrical Energy Meters WELMEC 11.8 2018 External Auxiliary of Electrical Energy Meters WELMEC is a cooperation between the legal metrology authorities of the Member States of the European Union and EFTA. This document is one

More information

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE DECLARATION OF PERFORMANCE Certificate No. 1. Unique ientification of the prouct-type: Lite See table here uner... 2. Type, batch or serial number or any other element allowing ientification of the construction

More information

PRECAST SQUARE COLUMN

PRECAST SQUARE COLUMN PRECAST SQUARE COUMN CODE OF COMPONENTS CS 3030-01 Product series 105 ap length to detail ink refer to schedule 1 1 ap length ap schedule Reinforcement ar Size (mm) ap ength (mm) 12 500 16 650 20 800 25

More information

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN Technical Data Sheet Issue: 20-02-2017 PUR-O-STOP FS-L General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN 1504-5 Properties: PUR-O-STOP FS-L is a slow-hardening,

More information

Sheet 1 Variable loading

Sheet 1 Variable loading Sheet 1 Variable loading 1. Estimate S e for the following materials: a. AISI 1020 CD steel. b. AISI 1080 HR steel. c. 2024 T3 aluminum. d. AISI 4340 steel heat-treated to a tensile strength of 1700 MPa.

More information

EU Declaration of conformity

EU Declaration of conformity EU Declaration of conformity Confirm with the Directive 2006/42/EC: of the European Parliament and of the Council of 17 May 2006 on the approximation of the laws of the Member States relating to machinery

More information

Chain-saws (combustion engine powered)

Chain-saws (combustion engine powered) Compliance Guide Rev.4.2, Edition 04/2018 Chain-saws (combustion engine powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206 68 66 This

More information

LIFTING ANCHOR SYSTEM CIVIL ENGINEERING TT 17-E

LIFTING ANCHOR SYSTEM CIVIL ENGINEERING TT 17-E LIFTING ANCHOR SYSTEM CIVIL ENGINEERING TT 17-E CONCRETE This catalogue conforms to the installation and application instructions according to the VDI/BV-BS 6205 guidelines Product Information Certified

More information