Fan-Powered Low-Height Series

Size: px
Start display at page:

Download "Fan-Powered Low-Height Series"

Transcription

1 Table of Contents Service Model Number Description LHS 2 3 General Data Valve/Controller Guidelines LHS 4 Performance Data Pressure Requirements LHS 5 7 Performance Data Fan Curves LHS 8 9 Performance Data Hot ater Coil LHS Performance Data Electrical Data LHS Performance Data coustics LHS Dimensional Data LHS Mechanical Specifications LHS VV-PRC008-EN LHS 1

2 Service Model Number Description Fan- Powered Terminal Units The features of the low-height series fan-powered terminal units are described by the product categories shown below in bold. ithin each category the options available are listed. LSCF LSF LSEF Digit 1, 2 Unit Type LS VariTrane low-height series fan-powered Digit 3 Reheat C Cooling Only E Electric Heat Hot ater Heat Digit 4 Development Sequence F Sixth Digit 5, 6 Primary ir Valve 06 6" inlet (500 cfm) 08 8" inlet (900 cfm) RT (8" x 14" inlet (1800 cfm) Digit 7, 8 Secondary ir Valve 00 N/ Digit 9 Fan H 08 Fan 850 maximum cfm J 09 Fan 1200 maximum cfm K 10 Fan 1900 maximum cfm Digit 10, 11 Design Sequence E0 Fifth (factory assigned) Digit 12, 13, 14, 15 Controls ENON No controls, field-installed DDC/electric PNON No controls, field-installed pneumatic DD00 Trane elec actuator only DD01 DDC cooling only DD02 DDC N.C. on/off water valve DD03 DDC prop hot water valve DD04 DDC on/off electric heat control DD05 DDC pulse-width modulation DD07 DDC N.O. on/off water valve FM00 FM customer actuator & control FM01 FM Trane actuator w/ customer VM2 actuator & control FM Johnson controls VM-1420 PR1 FM Seimens w/ GDE131.1P actuator PR4 FM Seimens Trane actuator PR5 FM Seimens w/ GDE131.1U actuator T01 T02 EI71 PN00 PN51 PN52 FM utomated Logic U341V+ FM utomated Logic U141V+ nalog fan-powered on/off reheat PN N.O. Trane pneumatic actuator, R.. stat PN N.O. PVR, duct pressure switch, R.. stat PN N.O. PVR, dual pressure switch, R.. stat Notes: N.C. = Normally-closed N.O. = Normally-opened D Stat = Direct-acting pneumatic t-stat (by others) R Stat = Reverse-acting pneumatic t-stat (by others) PN = Pneumatic FM = Factory installation of customersupplied controller Digit 16 Insulation 1/2" Matte-faced 1" Matte-faced C 1/2" Foil-faced D 1" Foil-faced F 1" Double-wall G 3/8" Closed-cell Digit 17 Motor Type D PSC Motor Digit 18 Motor Voltage 1 115/60/ /60/ /60/ /50/1 Digit 19 Outlet Connection 1 Flanged 2 Slip & Drive Digit 20 Not Used 0 N/ Digit 21 ater Coil 0 None 1 1-Row Plenum inlet installed 2 2-Row Plenum inlet installed 3 1-Row Discharge installed, Left-hand 4 1-Row Discharge installed, Right-hand 5 2-Row DIscharge installed, Left-hand 6 2-Row Discharge installed, Right-hand Digit 22 Electrical Connections L Left (airflow hitting you in the face) Digit 23 Transformer 0 N/ (provided as standard) Digit 24 Power Disconnect 0 None ith Digit 25 Power Fuse 0 None ith LHS 2 VV-PRC008-EN

3 Service Model Number Description Digit 26 Electric Heat Voltage 0 None 208/60/1 208/60/3 C 240/60/1 D 277/60/1 E 480/60/1 F 480/60/3 G 347/60/1 H 575/60/3 J 380/50/3 Digit 27, 28, 29 Electric Heat Voltage 000 None k k k k k k k k k k k k k k k k k k k k k k k k k k Digit 30 Electric Heat Stages 0 None 1 1 Stage 2 2 Stages Equal Digit 31 Contactors 0 None 1 24-Volt magnetic 2 24-Volt mercury 3 PE with magnetic 4 PE with mercury Digit 32 ir Flow Switch 0 None ith VV-PRC008-EN LHS 3

4 General Data Valve/Controller Guidelines Primary Control Factory Settings I-P Control ir Valve Maximum Valve Maximum Controller Minimum Controller Constant Volume Type Size (in.) Cfm Cfm Cfm Cfm , Direct Digital Control/ , UCM , x , , Pneumatic with , Volume Regulator , x , , nalog Electronic , , x , Primary Control Factory Settings SI Control ir Valve Maximum Valve Maximum Controller Minimum Controller Type Size (in.) L/s L/s L/s , Direct Digital Control/ , UCM , x , , Pneumatic with , Volume Regulator , x , , nalog Electronic , , x , Note: Maximum airflow must be greater than or equal to minimum airflow. LHS 4 VV-PRC008-EN

5 ir Pressure Drop in. wg (I-P) Inlet/Fan Cooling Only Size Cfm (in. wg) x x Fan 1-Row H Coil Size Cfm (in. wg) Performance Data ir Pressure Requirements ir Pressure Drop Pa (SI) Inlet/Fan Cooling Only Size L/s (Pa) x x Fan 1-Row H Coil Size L/s (Pa) Fan 2-Row H Coil Size CFM (in. wg) Notes: 1. Units with Electric Coils Only per fan size add 0.01" (3Pa) to cooling only values. 2. H Coil Only pressure drops are just the heating coil. Fan 2-Row H Coil Size L/s (Pa) VV-PRC008-EN LHS 5

6 Unit ir Pressure Drop in. wg (I-P) Inlet/Fan Cooling Size Cfm Only 05 08SQ SQ SQ SQ SQ x14 09SQ SQ x14 10SQ Fan-Powered Performance Data ir Pressure Requirements Coil ir Pressure Drop in. wg (I-P) Fan 1-Row H 2-Row H Size Cfm (in. wg) (in. wg) 08SQ SQ SQ Note: H Coil Only pressure drops do not include unit pressure drop. ttenuator ir Pressure Drop (I-P) Fan Plenum Size Cfm ttenuator 08SQ SQ SQ LHS 6 VV-PRC008-EN

7 Performance Data ir Pressure Requirements Unit ir Pressure Drop Pa (SI) Fan/Inlet Cooling Size L/s Only 05 08SQ SQ SQ SQ SQ x14 09SQ SQ x14 10SQ Coil ir Pressure Drop Pa (SI) Fan 1-Row H 2-Row H Size L/s (Pa) (Pa) 08SQ SQ SQ Note: H Coil Only pressure drops do not include unit pressure drop. ttenuator ir Pressure Drop (SI) Fan Plenum Size L/s ttenuator 08SQ SQ SQ VV-PRC008-EN LHS 7

8 Performance Data Fan Curves Pa In. wg SQ PSC Notes: 1. hen attenuator is required, add inlet attenuator pressure to discharge static pressure for final fan performance Discharge Static Pressure cfm min (80 L/s) Cfm L/s Pa 199 In. wg SQ PSC Discharge Static Pressure cfm min (165 L/s) LSCF and LSEF maximum Minimum 1-row coil maximum 2-row coil maximum Cfm L/s Pa 199 In. wg SQ PSC Discharge Static Pressure cfm min (191 L/s) LHS Cfm L/s VV-PRC008-EN

9 ECM Data Fan Curves Notes: 1. ECMs (Electrically Commutated Motors) are ideal for systems seeking maximum motor efficiency. 2. hen attenuator is required, add inlet attenuator pressure to discharge static pressure for final fan performance. Discharge Static Pressure Pa In. wg LSxF 08SQ ECM cfm min (47 L/s) Cfm L/s Pa In. wg LSxF 09SQ ECM LSCF and LSEF maximum Minimum 1-row coil maximum 2-row coil maximum Discharge Static Pressure cfm min (113 L/s) Cfm L/s Pa In. wg LSxF 10SQ ECM Discharge Static Pressure cfm min (189 L/s) Cfm L/s VV-PRC008-EN LHS 9

10 Performance Data Hot ater Coil (I-P) Fan Sizes 08SQ & 09SQ (I-P) ater Pressure (Cfm) Rows Gpm Drop (ft) Row Capacity MH Row Capacity MH Fan Size 10SQ (I-P) ater Pressure (Cfm) Rows Gpm Drop (ft) Row Capacity MH Row Capacity MH ater Coil Notes 1. Fouling Factor = The following equations may be used in calculating Leaving ir Temperature (LT) and ater Temperature Difference (TD). LT = ET + ( MH x Cfm 3. Capacity based on 70 F entering air temperature and 180 F entering water temperature. Refer to correction factors for different entering conditions. ) TD = ET - LT = ( ) 2 x MH Gpm Temperature Correction Factors for ater Pressure Drop (ft) verage ater Temperature Correction Factor Temperature Correction Factors for Coil Capacity (MH) Entering ater Minus Entering ir Correction Factor LHS 10 VV-PRC008-EN

11 Performance Data Hot ater Coil (SI) Fan Size 08SQ & 09SQ (SI) ater Pressure (L/s) Rows L/s Drop (kpa) Row Capacity MH Row Capacity MH Fan Size 10SQ (SI) ater Pressure (L/s) Rows L/s Drop (kpa) Row Capacity MH Row Capacity MH ater Coil Notes 1. Fouling Factor = The following equations may be used in calculating Leaving ir Temperature (LT) and ater Temperature Difference (TD). LT = ET + ( k x 0.83 L/s ) TD = ET - LT = ( k (4.19)L/s) 3. Capacity based on 21 C entering air temperature and 82 C entering water temperature. Refer to correction factors for different entering conditions. Temperature Correction Factors for ater Pressure Drop (kpa) verage ater Temperature Correction Factor Temperature Correction Factors for Coil Capacity (k) Entering ater Minus Entering ir Correction Factor VV-PRC008-EN LHS 11

12 Performance Data Electrical Data LSEF Electric Coil k Guidelines Minimum to Maximum (PSC Motor Units) Fan Single-Phase Voltage Three-Phase Voltage Size Stages 120V 208V 240V 277V 347V 480V 208V 480V 600V 08SQ 1 0.5* 4.5* * ** 09SQ 1 0.5* 4.5* * ** 10SQ 1 0.5* 4.0* * 4.0* ** *Special heater offering. **Three stages of electric heat available only with pneumatic controls. LSEF Electric Coil k Guidelines Minimum to Maximum (ECM Units) Fan Single-Phase Voltage Three-Phase Voltage Size Stages 120V 208V 240V 277V 347V 480V 208V 480V 600V 08SQ 1 0.5* 5.0* * 5.0* SQ 1 0.5* 4.5* * 4.5* SQ 1 0.5* 4.5* * 4.5* *Special heater offering Notes: 1. Coils available with 24 VC magnetic or mercury contactors, load carrying P.E. switches, and P.E. switch with magnetic or mercury contactors. 2. vailable k increments are by 0.5 from 0.5 k to 8.0 k and by 1.0 k from 9.0 to 18.0 k. 3. Each stage will be equal in k output. 4. ll heaters contain an auto thermal cutout and a manual reset cutout. 5. The current amp draw for the heater elements is calculated by the formula below. 6. Only two stages of electric reheat available with Trane controls. Fan Electrical Performance (PSC) Maximum Fan Motor mperage (FL) Fan Size HP 115 VC 277 VC 347 VC 08SQ 1/ SQ 1/ SQ 2 x 1/ Notes: 1. Electric Heat Units - Units with Primary Voltage of 208/60/1, 208/60/3 or 240/60/1 use 115 VC fan motors. 2. Electric Heat Units - Units with Primary Voltage of 277/60/1, 480/60/1 or 480/60/3 use 277 VC fan motors. 3. Electric Heat Units - Units with Primary Voltage of 347/60/1 or 575/60/3 use 347 VC fan motors. 4. Values are for standard, single-speed, permanent split capacitor type motors. Consult factory for non-standard motor performance. Fan Electrical Performance (ECM) Maximum Fan Motor mperage (FL) Fan Size HP 115 VC 277 VC 347 VC 08SQ 1/ SQ 1/ SQ 2 x 1/ Formulas Minimum Circuit mpacity (MC) Equation MC = (motor amps + heater amps) x 1.25 Maximum Overcurrent Protection (MOP) Equation MOP = (2.25 x motor amps) + heater amps General Sizing Rules: If MOP = 15, then fuse size = 15 If MOP = 19, then fuse size = 15 with one exception. If heater amps x 1.25 > 15, then fuse size = 20. If MOP MC, then choose next fuse size greater than MC. Control fusing not applicable. Standard Fuse Sizes: 15, 20, 25, 30, 35, 40, 45, 50, and 60. Useful formulas: Cfm x TD k = 3145 k x φamps = Primary Voltage x 3 TD = k x 3145 Cfm k = 1214 x L/s x TD 1φamps = TD = k 1214 x L/s k x 1000 Primary Voltage LHS 12 VV-PRC008-EN

13 Minimum Unit Electric Heat Cfm Guidelines (PSC) Unit Cfm k 08SQ 09SQ 10SQ Minimum Unit Electric Heat Cfm Guidelines (ECM) Unit Cfm k 08SQ 09SQ 10SQ Performance Data Electrical Data Minimum Unit Electric Heat L/s Guidelines (PSC) Unit L/s k 08SQ 09SQ 10SQ Minimum Unit Electric Heat L/s Guidelines (ECM) Unit L/s k 08SQ 09SQ 10SQ VV-PRC008-EN LHS 13

14 Performance Data coustics Discharge Sound Power (d) Discharge Sound Power (d) 0.5" Inlet 1.0" Inlet 2.0" Inlet 3.0" Inlet Fan Inlet Pressure (127 Pa) Pressure (254 Pa) Pressure (508 Pa) Pressure (762 Pa) Size Size Cfm L/s SQ SQ 8x SQ 8x ll data are measured in accordance with Industry Standard RI ll sound power levels, d re: atts. Radiated Sound Power (d) Radiated Sound Power (d) 0.5" Inlet 1.0" Inlet 2.0" Inlet 3.0" Inlet Fan Inlet Pressure (127 Pa) Pressure (254 Pa) Pressure (508 Pa) Pressure (762 Pa) Size Size Cfm L/s SQ SQ 8x SQ 8x ll data are measured in accordance with Industry Standard RI ll sound power levels, d re: atts. Fan Only Sound Power (d) Outlet Discharge Sound Power (d) Radiated Sound Power (d) Fan Static Octave and Octave ands Size (in. wg) Cfm L/s SQ (63 Pa) SQ (63 Pa) SQ (63 Pa) ll data are measured in accordance with Industry Standad RI ll sound power leves. d re: atts. LHS 14 VV-PRC008-EN

15 Performance Data coustics Sound Noise Criteria (NC) Fan and 100% Primary Radiated Discharge NC/NC with NC Level ttenuator Fan Inlet Fan 0.5" 1.0" 2.0" 3.0" Fan 0.5" 1.0" 2.0" 3.0" Size Size Cfm L/s Only (127 Pa) (254 Pa) (508 Pa) (762 Pa) Only (127 Pa) (254 Pa) (508 Pa) (762 Pa) 08SQ / 19/ 21/19 32/30 34/ /19 22/19 25/22 34/31 35/ /23 26/23 29/26 35/32 36/ /26 31/27 32/30 36/34 38/ /30 35/32 36/34 37/35 39/37 09SQ 8x /17 21/20 31/ / /22 26/25 32/29 37/34 38/ /29 34/32 35/32 37/34 39/ /31 37/35 38/36 40/ /35 38/37 38/37 40/39 42/40 10SQ 8x /24 25/21 29/25 35/29 36/ /27 27/24 31/27 37/31 42/ /30 34/30 34/30 39/34 44/ /34 39/36 40/37 45/ /39 42/40 46/42 1. represents NC levels below NC NC Values are calculated using modeling assumptions based on RI ddendum. RI add DISCHRGE TRNSFER FUNCTION SSUMPTIONS: Octave and Small ox (< 300 CFM) Medium ox ( CFM) Large ox (> 700 CFM) Subtract from terminal unit sound power to determine discharge sound pressure in the space. RI RDITED TRNSFER FUNCTION SSUMPTIONS: Octave and Type 2- Mineral Fiber Insulation Total d reduction Subtract from terminal unit sound power to determine radiated sound pressure in the space. VV-PRC008-EN LHS 15

16 Performance Data coustics Discharge Sound Power (d) Fan Only RI Conditions Fan Inlet Size Size Cfm L/s SQ 5, 6, SQ 6, 8, 8x SQ 8, 8x Radiated Sound Power (d) Fan Only RI Conditions Fan Inlet Size Size Cfm L/s SQ 5, 6, SQ 6, 8, 8x SQ 8, 8x Radiated Sound Power (d) Fan and Valve RI Conditions Fan Inlet Fan Fan Prim. Prim. 1.5" Inlet Pressure (381 Pa) Size Size Cfm L/s Cfm L/s SQ SQ x SQ x Notes: 1. ll data are measured in accordance with current Industry Standard RI 880, version ll sound power levels, d re: atts. LHS 16 VV-PRC008-EN

17 Performance Data coustics Inlet ttenuator ppurtenance Effects Discharge Sound Effect* (d) Radiated Sound Effect* (d) Fan Matte-faced and foil-faced insulation, solid double-wall** 08SQ, 09SQ SQ Closed-cell insulation 08SQ, 09SQ SQ *dd to sound power, a negative effect represents a sound reduction, a positive effect represents a sound increase **Note: ttenuators on double-wall units have 1" foil-faced insulation. ll edges are encapsulated with metal. Cabinet Lining ppurtenance Effects Discharge Sound Effect* (d) Radiated Sound Effect* (d) Fan Solid double-wall 08SQ, 09SQ SQ Closed-cell insulation 08SQ, 09SQ SQ *dd to sound power, a negative effect represents a sound reduction, a positive effect represents a sound increase Heating Coil ppurtenance Effects Discharge Sound Effect* (d) Radiated Sound Effect* (d) Fan Hot ater Coil** 08SQ, 09SQ SQ Electric Heat** 08SQ, 09SQ SQ * dd to sound power, a negative effect represents a sound reduction, a positive effect represents a sound increase **Radiated effect applies to fan only sound only. Do not apply to fan + valve sound. VV-PRC008-EN LHS 17

18 Dimensional Data LO-HEIGHT SERIES COOLING ONLY (LSCF) FN SIZES 08SQ & 09SQ FN SIZE 08SQ 09SQ 09SQ INLET SIZE INLET SIZE DISCHRGE DIMENSIONS Unit t VILILITY VILILITY H L C D Lbs NOMINL Ø (inches) NOMINL Ø (mm) (kg) 5, 6, 8 127, 152, " (279 mm) 26.00" (660 mm) 40.00" (1016 mm) 18.00" (457 mm) 10.00" (254 mm) 4.00" (102 mm) 4.00" (102 mm) 86 (39) 6, 8 152, (44) 8 x x " (152 mm) 4.50" (114 mm) 105 (47) Optional ttenuator 4. ctuator, Controller and D 32.00" (813 mm) Plenum Inlet 4. ctuator, Controller and Primary Optional ttenuator 18.00" (457 mm) ir Valve C 17.50" (445 mm) Rectangular Damper 8" x 14" (203 mm x 356 mm) Rectangular Damper Detail 5.00" (127 mm) L 4. ctuator, Controller and Fan Size Filter Size tten t Lbs (kg) 08SQ 10" x 10" x 1" 09SQ (254 mm x 254 mm x 25 mm) 10 (4.5) 7. NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange. Discharge Outlet 3. ottom ccess panel standard. TOP VIE 4. Control box enclosure provided with all control types. 5. ir valve centered between top and bottom panel. 6. ll high & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 7. Flange adds 2" to width and length of unit " (267 mm) H LHS 18 DISCHRGE VIE 1.00" (25 mm) VV-PRC008-EN

19 Dimensional Data LO-HEIGHT SERIES COOLING (LSCF) FN SIZE 10SQ FN INLET SIZE INLET SIZE SIZE VILILITY NOMINL Ø (INCHES) NOMINL Ø (mm) 10SQ 10SQ 8 8 x x 356 DISCHRGE DIMENSIONS H L 48.00" (1219 mm) 36.00" (914 mm) 38.00" (965 mm) UNIT T C D T LS (kg) 4.00" (102 mm) 20.00" (508 mm) 120 (54) 6.00" (152 mm) 17.50" (445 mm) 130 (59) Optional ttenuator 2. O ator ed ctuator, Controller and 32.00" 32.00" (813 mm) (813 mm) 18.00" (457 mm) Optional ttenuator D Plenum Inlet Primary Plenum Inlet Optional ttenuator Rectangular Damper Detail Rectangular Damper 8" x 14" (203 mm x 356 mm) 17.50" (445 mm) 5.00" (127 mm) L 9. Fan Size 10SQ Filter Size 10" x 16" x 1" (254 mm x 406 mm x 25 mm) tten t Lbs (kg) 20 (9) NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. Discharge Outlet 2. Filter location with optional ttenuator. 3. ttenuator-factory assembled, field installed. 4. ir valve centered between top and bottom panel. TOP VIE 5. Heating coil uninsulated. External insulation may be field supplied and installed as required. 6. ll high & low voltage controls have same-side NEC jumback clearance. (Left-hand shown, right-hand available.) 7. ottom ccess panel standard. H 10.50" (267 mm) 8. Control box enclosure provided with all control types. 9. Flange adds 2" to width and length of unit. DISCHRGE VIE VV-PRC008-EN LHS 19

20 Dimensional Data LO-HEIGHT SERIES HOT TER (LSF) FN SIZES 08SQ & 09SQ FN SIZE 08SQ 09SQ 09SQ INLET SIZE VILILITY NOMINL Ø INLET SIZE NOMINL Ø (mm) 6, 8 152, x x 355 H DISCHRGE DIMENSIONS L 26.00" (660 mm) 40.00" (1016 mm) 18.00" (457 mm) C D Unit t Lbs (kg) 105 (48) 114 (52) Optional ttenuator 4. ctuator, Controller and Fan Controls located in Enclos 32.00" (813 mm) D Plenum Inlet 4. ctuator, Controller and Primary Optional ttenuator 18.00" (457 mm) ir Valve C 17.50" (445 mm) Rectangular Damper 8" x 14" (203 mm x 356 mm) Rectangular Damper Detail 5.00" (127 mm) L ctuator, Controller and Fan Size 08SQ 09SQ Filter Size 10" x 10" x 1" (254 mm x 254 mm x 25 mm) tten t Lbs (kg) 10 (4.5) 8. TOP VIE ater Coil 6.80" (173 mm) NOTES: Discharge Outlet 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange. 3. ottom ccess panel standard. 4. Control box enclosure provided with all control types. 5. ir valve centered between top and bottom panel " (267 mm) H 6. Heating coil uninsulated. External insulation may be field supplied and installed as required. 7. ll high & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 8. Flange adds 2" to width and length of unit. LHS 20 DISCHRGE VIE 1.00" (25 mm) VV-PRC008-EN

21 Dimensional Data LO-HEIGHT SERIES HOT TER (LSF) FN SIZE 10SQ FN INLET SIZE INLET SIZE DISCHRGE DIMENSIONS SIZE VILILITY H L NOMINL Ø (INCHES) NOMINL Ø (mm) 10SQ 10SQ 8 8 x x " (279 mm) 48.00" (1219 mm) 36.00" (914 mm) 38.00" (965 mm) C 6.00" (152 mm) D UNIT T T LS (kg) 146 (66) ator d tor d 8. ctuator, Controller and 8. ctuator, Controller and 32.00" 32.00" (813 mm) (813 mm) " (457 mm) Optional ttenuator D Plenum Inlet Primary Optional ttenuator Plenum Inlet Rectangular Damper Detail C Rectangular Damper 8" x 14" (203 mm x 356 mm) 17.50" (445 mm) 8. ctuator, Controller and L 5.00" (127 mm) Fan Size Filter Size tten t Lbs (kg) 10SQ 10" x 16" x 1" (254 mm x 406 mm x 25 mm) 20 (9) Discharge Outlet TOP VIE 6.80" (173 mm) NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Filter location with optional ttenuator. 3. ttenuator-factory assembled, field installed. 4. ir valve centered between top and bottom panel. 5. Heating coil uninsulated. External insulation may be field supplied and installed as required. 6. ll high & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 7. ottom ccess panel standard. 8. Control box enclosure provided with all control types " (267 mm) H DISCHRGE VIE VV-PRC008-EN LHS 21

22 H Fan-Powered Dimensional Data COIL INFORMTION FOR LO-HEIGHT SERIES 1-RO COIL FN SIZE COIL CONNECTION L H 08SQ.875" (22 mm) O.D. 7.75" (197 mm) 1.50" (38 mm) 18.00" (457 mm) 10.00" (254 mm) 6.80" (173 mm) 09SQ 10SQ 38.00" (965 mm) 3.40" (86 mm) INLET IR FLO 7.81" (198 mm) IR FLO CCESS PNEL Fan Size 08SQ 09SQ INTERNL VOLUME GL (L) OPERTING EIGHT LS (KG) 0.07 (.28) 10.4 (4.7) 1.00" (25 mm) 10SQ 0.15 (.59) 16.4 (7.4) 2.00" (51 mm) NOTES: 1. Location of coil connections is determined by facing air stream. L.H. coil connections shown, R.H. opposite. 2. Coil furnished with stub sweat connections. 3. Coils can be field-rotated for opposite connections. Note: ater inlet is always the bottom connection. 4. ccess panel is standard. LHS 22 VV-PRC008-EN

23 H Fan-Powered Dimensional Data COIL INFORMTION FOR LO-HEIGHT SERIES 2-RO COIL FN SIZE COIL CONNECTION L H 08SQ.875" (22 mm) O.D. 6.25" (159 mm) 2.00 (51 mm) 18.00" (457 mm) 10.00" (254 mm) 6.75" (171 mm) 09SQ 10SQ 38.00" (965 mm) L 3.40" (86 mm) INLET 7.81" (198 mm) IR FLO IR FLO INLET CCESS PNEL Fan Size INTERNL VOLUME GL (L) OPERTING EIGHT LS (KG) 1.00" (25 mm) 08SQ 09SQ 0.11 (.45) 11.1 (5.0) 2.00" (51 mm) 10SQ 0.24 (.94) 23.0 (10.4) NOTES: 1. Location of coil connections is determined by facing air stream. L.H. coil connections shown, R.H. opposite. 2. Coil furnished with stub sweat connections. 3. Coils can be field-rotated for opposite connections. Note: ater inlet is always the bottom connection. 4. ccess panel is standard. VV-PRC008-EN LHS 23

24 Dimensional Data LO-HEIGHT SERIES ELECTRIC HET (LSEF) FN SIZES 08SQ & 09SQ FN INLET SIZE INLET SIZE DISCHRGE DIMENSIONS Unit t SIZE VILILITY VILILITY H L C D Lbs NOMINL Ø (INCHES) NOMINL Ø (mm) (kg) 08SQ 5, 6, 8 127, 152, " (279 mm) 26.00" (660 mm) 40.00" (1016 mm) 14.00" (356 mm) 9.00" (229 mm) 4.00" (102 mm) 4.00" (102 mm) 101 (45.8) 09SQ 6, 8 152, SQ 8 x x " (152 mm) 4.50" (114 mm) 120 (54.4) tional ttenuator 4. ctuator, Controller and 32.00" (813 mm) 4. D Plenum Inlet ctuator, Controller and Primary Optional ttenuator 18.00" (457 mm) ir Valve C 17.50" (445 mm) Rectangular Damper 8" x 14" (203 mm x 356 mm) Rectangular Damper Detail 5.00" (127 mm) L 4. ctuator, Controller and 8. Fan Size 08SQ 09SQ Filter Size 10" x 10" x 1" (254 mm x 254 mm x 25 mm) tten t Lbs (kg) 10 (4.5) 20.00" (508 mm) Electric Heater TOP VIE NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Flanged discharge outlet accepts up to 1" (25 mm) duct flange. 3. ottom ccess panel standard. 4. Control box enclosure provided with all control types. Discharge Outlet 5. ir valve centered between top and bottom panel. 6. Heating coil uninsulated. External insulation may be field supplied and installed as required. 7. ll hight & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 10.50" (267 mm) H 8. Flange adds 2" to width and length of unit. LHS 24 DISCHRGE VIE VV-PRC008-EN

25 Dimensional Data LO-HEIGHT SERIES ELECTRIC (LSEF) FN SIZE 10SQ FN INLET SIZE INLET SIZE SIZE VILILITY VILILITY NOMINL Ø (INCHES) NOMINL Ø (mm) 10SQ SQ 8 x x 356 H 11.00" (279 mm) 48.00" (1219 mm) DISCHRGE DIMENSIONS L 36.00" (914 mm) 25.30" (643 mm) UNIT T C D T LS (kg) 6.00" (152 mm) 155 (70.3) Optional ttenuator 8. ctuator, Controller and 8. ctuator, Controller and 32.00" 32.00" (813 mm) (813 mm) Optional ttenuator Optional ttenuator 18.00" (457 mm) D Plenum Inlet Primary C Plenum Inlet Rectangular Dam Rectangular Damper 8" x 14" (203 mm x 356 mm) " (445 mm) ctuator, Controller and L 5.00" (127 mm) 9. Fan Size 10SQ Filter Size 10" x 16" x 1" (254 mm x 406 mm x 25 mm) tten t (Qty 2) Lbs (kg) 20 (9.1) 24.00" (610 mm) Terminal ox Heater Plenum rea 11.00" (279 mm) 8.00" (203 mm) NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Filter location with optional ttenuator. 3. ttenuator-factory assembled, field installed. Discharge Outlet TOP VIE 4. ir valve centered between top and bottom panel. 5. Heating coil uninsulated. External insulation may be field supplied and installed as required. 6. ll high & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 7. ottom ccess panel standard. 8. Control box enclosure provided with all control types. H 10 ( Flange adds 2" to width and length of unit. DISCHRGE VIE VV-PRC008-EN LHS 25

26 Mechanical Specifications MODELS LSCF, LSF, and LSEF Low-height series fan-powered terminal units. LSCF Cooling Only LSF ith Hot ater Coil LSEF ith Electric Coil CSING 22-gage galvanized steel. Hanger brackets, bottom access, and plenum inlet filter are provided as standard. GENCY LISTING The unit is UL and Canadian UL Listed as a room air terminal unit. Control # 9N65. RI 880 Certified. INSULTION 1/2" (12.7 mm) Matte-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with ½-inch, 1.75 lb/ft 3 (12.7 mm, kg/m 3 ) composite density glass fiber with a high-density facing of 4.0 lb/ft 3 (64 kg/m 3 ). The insulation R-Value is 1.9. The insulation is UL listed and meets NFP-90 and UL 181 standards. There are no exposed edges of insulation (complete metal encapsulation). 1" (25.4 mm) Matte-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1-inch, 1.55 lb/ft 3 (25.4 mm, 24.8 kg/m 3 ) composite density glass fiber with a high-density facing of 4.0 lb/ft 3 (64 kg/m 3 ). The insulation R-Value is The insulation is UL listed and meets NFP- 90 and UL 181 standards. There are no exposed edges of insulation (complete metal encapsulation). 1/2" (12.7 mm) Foil-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with ½-inch, 2.0 lb/ft 3 (12.7 mm, kg/m 3 ) density glass fiber with foil facing. The insulation R-Value is 2.2. The insulation is UL listed and meets NFP-90 and UL 181 standards as well as bacteriological standard STM C 665. There are no exposed edges of insulation (complete metal encapsulation). 1" (25.4 mm) Foil-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1-inch, 2.0 lb/ft 3 (25.4 mm, kg/m 3 ) density glass fiber with foil facing. The insulation R-Value is 4.3. The insulation is UL LHS 26 listed and meets NFP-90 and UL 181 standards as well as bacteriological standard STM C 665. There are no exposed edges of insulation (complete metal encapsulation). 1" (25.4 mm) Double-wall Insulation The interior surface of the unit casing is acoustically and thermally lined with a 1-inch, 2.1 lb./ft 3 (25.4 mm, 33.6 kg/m 3 ) composite density glass fiber with high-density facing. The insulation R-value is 3.0. The insulation is UL listed and meets NFP- 90 and UL 181 standards. The insulation is covered by an interior liner made of 26-gage galvanized steel. ll wire penetrations are covered by grommets. There are no exposed edges of insulation (complete metal encapsulation). 3/8" (9.5 mm) Closed-cell Insulation The interior surface of the unit casing is acoustically and thermally lined with 3/8-inch, 4.4 lb/ft 3 (9.5 mm, 40.0 kg/m 3 ) closed-cell insulation. The insulation is UL listed and meets NFP-90 and UL 181 standards. The insulation has an R-value of 1.4. There are no exposed edges of insulation (complete metal encapsulation). PRIMRY IR VLVE ir Valve Round The primary air inlet connection is an 18-gage galvanized steel cylinder sized to fit standard round duct. multiple-point, averaging flow sensing ring is provided with balancing taps for measuring +/-5% of unit cataloged airflow. n airflow-versus-pressure differential calibration chart is provided. The damper blade is constructed of a closed-cell foam seal that is mechanically locked between two 22-gage galvanized steel disks. The damper blade assembly is connected to a cast zinc shaft supported by selflubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over-stroking. t 4.0 in. wg, air valve leakage does not exceed 1% of cataloged airflow. ir Valve Rectangular Inlet collar is constructed of 22-gage galvanized steel sized to fit standard rectangular duct. n integral multiple-point, averaging flow-sensing ring provides primary airflow measurement within +/ -5% of unit cataloged airflow. Typical inlet conditions: flex duct and 90 inlets to the damper. Damper is 22-gage galvanized steel with polyolefin foam seal. The damper blade assembly is connected to a solid metal shaft supported by self-lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over-stroking. t 3.0 in. wg, air valve leakage does not exceed 44 cfm (21 L/s). Fan Inlet Combinations: LSXF Inlet 08Q 09SQ 10SQ 5" X 6" X X 8" X X X 8x14" X X FN MOTOR PSC Single-speed, direct-drive, permanent split capacitor type. Thermal overload protection provided. Motors will be designed specifically for use with an open SCR. Motors will be single-speed with standard SCR for speed control. Motors will accommodate anti-backward rotation at start up. Motor and fan assembly is isolated from terminal unit. ECM Electrically Commutated Motor is desinged for high-efficient operation with over 70% efficiency throughout the operating range. FN SPEED CONTROL Variable Speed Control Switch (SCR) The SCR speed control device is provided as standard and allows the operator infinite fan speed adjustment so the fan output may be modified to achieve exact cfm requirements. TRNSFORMER The 50 V transformer is factoryinstalled in the fan control box to provide 24 VC for controls. POER DISCONNECT The power disconnect is provided as standard and allows the operator to turn the unit on or off by toggling to the appropriate setting. This switch breaks both legs of power to the fan and the electronic controls (if applicable). Not provided on LSEF with pneumatic controls OUTLET CONNECTION Flanged Connection rectangular opening on the unit discharge to accept a 90 flanged ductwork connection. FILTER 1" (25 mm) filter is provided on the plenum inlet and attaches to the unit with a filter frame. VV-PRC008-EN

27 Mechanical Specifications CCESS PNEL Internal access to unit is achieved through the removable bottom access panel. HOT TER COIL ater Coils factory-installed on the plenum inlet. The coil has 1-row with 144 aluminumplated fins per foot (.305 m) and, if needed, 2-row with 144 aluminumplated fins per foot (.305 m). Full fin collars provided for accurate fin spacing and maximum fin-tube contact. The 3/8" (9.5 mm) OD seamless copper tubes are mechanically expanded into the fin collars. Coils are proof tested at 450 psig (3102 kpa) and leak tested at 300 psig (2068 kpa) air pressure under water. Coil connections are brazed with left-hand configuration. ELECTRIC HET COIL The electric heater is a factory-provided and -installed, UL recognized resistance open-type heater. It also contains a disc-type automatic pilot duty thermal primary cutout, and manual reset load carrying thermal secondary device. Heater element material is nickel-chromium. The heater terminal box is provided with 7/8" (22 mm) knockouts for customer power supply. Terminal connections are plated steel with ceramic insulators. Heater control access is on the discharge side of the unit. ll fanpowered units with electric reheat are single-point power connections. ELECTRIC HET OPTIONS Magnetic Contactor n optional electric heater 24-volt contactor for use with direct digital control (DDC) or analog-electronic controls. Mercury Contactor n optional electric heater 24-volt contactor for use with direct digital control (DDC) or analog-electronic controls. P.E. Switch with Magnetic Contactor This optional switch and magnetic contactor is for use with pneumatic controls. P.E. Switch with Mercury Contactor This optional switch and mercury contactor is for use with pneumatic controls. Switch n optional air pressure device designed to disable the heater when the system fan is off. Power Fuse If power fuse is chosen with a unit with electric heat, then a safety fuse located in the line of power of the electric heater to prevent power surge damage to the electric heater. ny electric heat unit with a calculated MC greater than or equal to 30 will have a fuse provided Disconnect Switch n optional factory-provided door interlocking disconnect switch on the heater control panel disengages primary voltage to the terminal. UNIT CONTROLS SEQUENCE OF OPERTION The controller will start and run the fan continuously during the occupied mode and intermittently during the unoccupied mode. Upon a further call for heat, any hot water or electric heat associated with the unit is enabled. DIRECT DIGITL CONTROLS DDC ctuator Trane 3-wire, 24-VC, floating-point control actuator with linkage release button. Torque is 35 in-lb minimum and is non-spring return with a 90-second drive time. Travel is terminated by end stops at fully-opened and -closed positions. n integral magnetic clutch eliminates motor stall. Direct Digital Controller The microprocessor based terminal unit controller provides accurate, pressureindependent control through the use of a proportional integral control algorithm and direct digital control technology. The controller, named the Unit Control Module (UCM), monitors zone temperature setpoints, zone temperature and its rate of change, and valve airflow using a differential pressure signal from the pressure transducer. dditionally, the controller can monitor either supply duct air temperature or CO 2 concentration via appropriate sensors. The controller is provided in an enclosure with 7/8" (22 mm) knockouts for remote control wiring. Trane UCM zone sensor is required. DDC Zone Sensor The UCM controller senses zone temperature through a sensing element located in the zone sensor. In addition to the sensing element, zone sensor options may include an externally-adjustable setpoint, communications jack for use with a portable edit device, and an override button to change the individual controller from unoccupied to occupied mode. The override button has a cancel feature that will return the system to unoccupied. ired zone sensors utilize a thermistor to vary the voltage output in response to changes in the zone temperature. iring to the UCM controller must be 18- to 22-awg. twisted pair wiring. The setpoint adjustment range is 50 88ºF (10 31 C). Depending upon the features available in the model of sensor selected, the zone sensor may require from a 2-wire to a 5-wire connection. ireless zone sensors report the same zone information as wired zone sensors, but do so using radio transmitter technology. Therefore with wireless, wiring from the zone sensor to the UCM is unnecessary. Digital Display Zone Sensor with Liquid Crystal Display (LCD) The digital display zone sensor contains a sensing element, which sends a signal to the UCM. Liquid Crystal Display (LCD) displays setpoint or space temperature. Sensor buttons allow the user to adjust setpoints, and allow space temperature readings to be turned on or off. The digital display zone sensor also includes a communication jack for use with a portable edit device, and an override button to change the UCM from unoccupied to occupied. The override button has a cancel feature, which returns the system to unoccupied mode. Trane LonTalk The controller is designed to send and receive data using SCC LonTalk profile. Current unit status conditions and setpoints may be monitored and/or edited from any of several LonTalk-compatible systemlevel controllers NLOG ELECTRONIC CONTROLS nalog ctuator Trane 3-wire, 24-VC, floating-point control actuator with linkage release button. Torque is 35 in-lb minimum and is non-spring return with a 90-second drive time. Travel is terminated by end stops at fully-opened and -closed positions. n integral magnetic clutch eliminates motor stall. nalog Electronic Controller The controller consists of a circuit board that offers basic VV unit operation and additional override functions and operates using 24 VC power. The VV-PRC008-EN LHS 27

Fan-Powered Parallel

Fan-Powered Parallel Table of Contents Service Model Number Description FPP 2 Selection Procedure FPP 3 5 General Data Valve/Controller Guidelines FPP 6 Performance Data ir Pressure Requirements FPP 7 8 Performance Data Fan

More information

Fan-Powered Low-Height Series

Fan-Powered Low-Height Series Table of Contents Model Number Description PS 2 Service Model Number Description PS 3 General Data Valve/Controller irflow Guidelines PS 4 Performance Data Pressure Requirements PS 5 Performance Data Fan

More information

Single-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6

Single-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6 Table of Contents Model Number Description SD 2 3 Service Model Number Description SD 4 Selection Procedure SD 5 6 General Data Valve/Controller Airflow Guidelines SD 7 Performance Data Pressure Requirements

More information

Fan-Powered Series. Table of Contents. Model Number Description FPS 2 3. Service Model Number Description FPS 4. Selection Procedure FPS 5 7

Fan-Powered Series. Table of Contents. Model Number Description FPS 2 3. Service Model Number Description FPS 4. Selection Procedure FPS 5 7 Table of Contents Model Number Description FPS 2 3 Service Model Number Description FPS 4 Selection Procedure FPS 5 7 General Data Valve/Controller Airflow Guidelines FPS 8 Performance Data Pressure Requirements

More information

Fan-Powered Parallel

Fan-Powered Parallel Table of Contents Model Number Description 76 Selection Procedure 77-79 General Data Setting Guidelines 80 Performance Data Pressure Requirements 81 Performance Data Fan Curves 82-85 Performance Data Hot

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

Installation, Operation, and Maintenance

Installation, Operation, and Maintenance Installation, Operation, and Maintenance VariTrane Single-Duct and Fan-Powered Units All VariTrane VAV models with pneumatic, electronic, DDC controls, and diffusers. VCCF04-24 VCEF04-24 VCF04-24 SAFETY

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SDL Single-Duct, Low-Height, VAV Terminals

SDL Single-Duct, Low-Height, VAV Terminals SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely

More information

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals catalog SDL Single-Duct, Low-Height, VAV Terminals Catalog: ET130.13-EG2 (708) TABLE OF CONTENTS Single-Duct, Low-Height VAV Terminals Features and Benefits....................... 2 Controls..................................

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals catalog SDL Single-Duct, Low-Height, VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 3 Construction Features... 4 Standard and Optional Features.... 5 Dimensional and Weight Data....

More information

HOW TO SPECIFY SDV UNITS

HOW TO SPECIFY SDV UNITS HOW TO SPECIFY SDV UNITS MODEL UNIT CONFIG LINER CASING OPTIONS CONST. SIDE INLET SIZE DISCHARGE OPTIONS CONTROL TYPE UNIT ACCESSORIES HEAT kw ELECTRIC HEAT ACCESSORIES SCR HEAT ACCESSORIES SDV 0 - Standard

More information

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals Product Data 5J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals 90 to 3900 Cfm Series Fan Box 5J,K,Q Parallel Fan Box 5M,N,R 5J,M 5K,N 5Q,R The 5J,M,K,N,Q,R units were

More information

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm Product Data 35E Single Duct Terminal Units for Variable Air Volume Systems Nominal 45 to 7100 cfm Single duct variable air volume (VAV) terminal units provide: 22-gage galvanized steel, unit casing lined

More information

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES 30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals. Product Data 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals 90 to 3900 Cfm 45J,M 45K,N 45Q,R The 45J,M,K,N,Q,R units were designed to maintain accurate temperatures

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

TSS Single-Duct VAV Terminals

TSS Single-Duct VAV Terminals TSS Single-Duct VAV Terminals Model TSS construction features Standard Construction Mechanical-lock construction ensures lowest possible casing leakage Roll-formed inlet collar with integral stiffening

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

IAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW

IAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW SINGLE DUCT w/hot WATER HEAT Model AVW Model AVW The Carnes Model AVW is available as a basic control unit with hot water reheat and open end discharge, with an optional sound attenuator module, and optional

More information

SINGLE DUCT AIR TERMINAL UNITS

SINGLE DUCT AIR TERMINAL UNITS AIR terminal units AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units are at the core of

More information

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL Fan Powered Terminals VAV TERMINALS IOM FAN POWERED TERMINALS Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage is

More information

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

IAQ. Model AVC. SINGLE DUCT VAV Model AVC NON FAN POWERED UNITS SINGLE DUCT VAV Model AVC Model AVC The Carnes Model AVC is available as a basic control unit with open end discharge, with an optional multi-discharge adapter module, or sound attenuator

More information

SINGLE DUCT TERMINAL UNITS 3000 SERIES

SINGLE DUCT TERMINAL UNITS 3000 SERIES 000 SERIES 000 SERIES VRIBLE OR CONSTNT VOLUME PRODUCT OVERVIE Nailor 000 Series Single Duct Terminal units are simply put, versatile. hether the requirement calls for a constant or variable air volume

More information

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101) 500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 23 3600 - AIR TERMINAL DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fan-powered air terminal units/devices. 2. Shut off air terminal units/devices. 3. Dual duct terminal units/devices.

More information

FDCLP2 Constant Volume Series Flow, Low Profile

FDCLP2 Constant Volume Series Flow, Low Profile The Price low profile series fan powered terminal unit is an ideal product for use in typical series fan powered applications with limited ceiling space. The is designed for constant air volume applications,

More information

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI Air Terminal Units Models MQTH, MQFCI and MQFVI Catalog 903-1 Model MQTH Model MQFCI Model MQFVI Table of Contents Single Duct Air Terminal Units.... 3 Introduction....3 MQTH-500 Single Duct Air Terminal

More information

Laboratory Room Single Duct Supply Air Terminal

Laboratory Room Single Duct Supply Air Terminal Technical Specification Sheet Document No. 149-319A June 24th, 2010 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The APOGEE Automation

More information

Variable Air Volume (VAV) Pressure Independent Control

Variable Air Volume (VAV) Pressure Independent Control VAV Terminal Units Asli Variable Air Volume (Vav) Terminal Units are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of conditioned

More information

Product Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems

Product Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems Product Data AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems 45UC 35BF-R 42KC 45XC 35BF-D Features/Benefits Access Floor Systems can provide flexibility and economic

More information

I Fan Powered Terminal Unit

I Fan Powered Terminal Unit I Fan Powered Terminal Unit VARIABLE VOLUME PARALLEL FLOW Fan Powered Terminal Unit Variable volume parallel flow Product Overview Variable Volume/Parallel Flow Fan Powered Terminal Units Honeywell parallel

More information

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional

More information

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED Direct Drive, Draw-through Design Model Series 3FH Filter 1" (2) throwaway (standard) 2" (1) MERV 8 or MERV 13 pleated (optional) Multiple coil options: 3, 4,, 6 row cooling or heating coils 1 or 2 row

More information

FCVC Series VERTICAL FAN COILS

FCVC Series VERTICAL FAN COILS VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,

More information

Dual Duct Variable Air Volume Terminal (Model TDS)

Dual Duct Variable Air Volume Terminal (Model TDS) Product Bulletin Issue Date June 21st, 2005 Dual Duct Variable Air Volume Terminal (Model TDS) Model TDS terminals provide Variable Air Volume (VAV) control beyond the typical dual duct box. They are specifically

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also

More information

IAQ. ROUND DUCT RETROFIT Model ARR

IAQ. ROUND DUCT RETROFIT Model ARR Non Fan Powered Units ROUND DUCT RETROFIT Model ARR IAQ External Insulation Standard The Carnes Model ARR offers low pressure drop, low sound levels, and valve characteristics which create stable control

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

AIR FLOW SOLUTIONS. MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit. MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit

AIR FLOW SOLUTIONS. MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit. MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit IOM 002 Effective 4/06 AIR FLOW SOLUTIONS Installation, Operation, & Maintenance MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit

More information

Submittal. Front View Side View

Submittal. Front View Side View RBHO Horizontal Low Profile Concealed Free Return Submittal FCU-RBHO-1.0 07-25-18 Top View (Drain Pan Omitted) Bottom View Front View Side View Left hand unit shown. All dimensions are inches [millimeters].

More information

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778] FCU-THBP-1.0 08-22-18 THBP Horizontal Low Profile Plenum Return Top View (Drain Pan Omitted) Bottom View Front View Left hand unit shown. All dimensions are inches [millimeters]. Side View Unit Size A

More information

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated

More information

Product Catalog. VariTrane Products Single Duct/Dual Duct Units VDD, VCC, VCW, VCE VAV-PRC011M-EN. Variable-Air-Volume (VAV) System.

Product Catalog. VariTrane Products Single Duct/Dual Duct Units VDD, VCC, VCW, VCE VAV-PRC011M-EN. Variable-Air-Volume (VAV) System. Product Catalog VariTrane Products Single Duct/Dual Duct Units VDD, VCC, VCW, VCE Variable-Air-Volume (VAV) System EA RA OA supply fan PA cooling coil variablespeed drive VAV box thermostat SA March 2015

More information

VariTrane VAV Terminal Unit. Single-Duct Series Fan-Powered Parallel Fan-Powered

VariTrane VAV Terminal Unit. Single-Duct Series Fan-Powered Parallel Fan-Powered VariTrane VV Terminal Unit Singleuct Series FanPowered Parallel FanPowered Contents VV System Overview VariTrane VV Terminal Unit Overview Model escription Singleuct Terminal Units Model escription FanPowered

More information

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View. Horizontal Low Profile oncealed with Plenum FU-RBHR-1.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041]

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

catalog SDR Single-Duct VAV Terminals

catalog SDR Single-Duct VAV Terminals catalog SDR Single-Duct VAV Terminals TABLE OF CONTENTS Features And Benefits...2 Standard Construction...6 Optional Construction...7 Standard And Optional Features...8 Application And Selection...9 Airflow

More information

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations. Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open

More information

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper. Application The WD200 series are electrically motorized backdraft dampers that open when energized and spring return close when deenergized. The WD200 series are for horizontal or vertical mounting. Primary

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Laboratory Room Single Duct Supply Air Terminal

Laboratory Room Single Duct Supply Air Terminal Technical Specification Sheet Document No. 149-319P25 July 28, 2017 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The Laboratory Room

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model

More information

FN Fan-Coil Units High-Performance, Horizontal

FN Fan-Coil Units High-Performance, Horizontal FN Fan-Coil Units High-Performance, Horizontal Model FNX Exposed-Cabinet Dimensional Data Notes: 1. All dimensions are in inches [mm] and are +/- 1/8" [3 mm]. Metric values are soft conversions. 2. See

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL

More information

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification Date: October 22, 1999 Rev: 00 Doc. No. AG-LHK-01 Application Guide This Application Guide has been developed to introduce the LHK access floor fan powered terminal. In this Guide you will find a description

More information

Product Data Manual. ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e

Product Data Manual. ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e Product ata Manual ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e Table of Contents Physical ata - Nomenclature Options............................................. 3 Effectiveness Performance ata.................................................

More information

AIR 3 1/4" [ 83 ] ELECTRICAL CONTROL BOX FOAM LINED CONNECTION SLOPED DRAIN PAN EXTERNALLY INSULATED WITH FOAM SHIPPED LOOSE FOR FIELD INSTALLATION

AIR 3 1/4 [ 83 ] ELECTRICAL CONTROL BOX FOAM LINED CONNECTION SLOPED DRAIN PAN EXTERNALLY INSULATED WITH FOAM SHIPPED LOOSE FOR FIELD INSTALLATION 5 7/8".0 55 " [ 5 ] IVERTER SLIES INTO ISCHARGE UCTORK E LH CONFIG. SHON HANING ETERMINE BY L FILTER FOAM LINE SLOPE RAIN PAN ETERNALLY INSULATE ITH FOAM SHIPPE LOOSE FOR FIEL INSTALLATION /" [ 8 ] H H

More information

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017 Replacement Parts List No. 700020000 Revision J 07/2017 Daikin McQuay VAV Air Terminal Unit MQ FCI6, FVI5, THI5 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

More information

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A E N G I N E E R I N G D T I R H N D L E R S CB29M Multi Position 60 HZ Bulletin No. 210478 November 2008 Supersedes July 2007 3 to 5 Tons Optional Electric Heat 5 to 30 kw MODEL NUMBER IDENTIFICTION CB

More information

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE

More information

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS D2 RETROFIT/YPASS TERMINA UNITS Table of Contents RETROFIT/YPASS TERMINA UNITS RVE This retrofit terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable

More information

Technical information

Technical information 6-8 Application Rectangular NK and NL types are pressure-independent VAV and CAV air volume control terminals. The terminals are designed particularly for systems with large air volumes and duct sizes

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE Low Power Consumption, Accessible, & FW and FL Fan-Coil Design Features Owners Owners can choose between a standard height (FW)

More information

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS INSTALLATION OPERATION & MAINTENANCE New Release Form 130.13-NOM4 (908) In conjunction with the use of these instructions, obtain and refer to the construction,

More information

IOM 002 Effective 12/17 A I R D I S T R I B U T I O N M O D E L Q S T M O D E L Q P T M O D E L E S T

IOM 002 Effective 12/17 A I R D I S T R I B U T I O N M O D E L Q S T M O D E L Q P T M O D E L E S T IOM 002 Effective 12/17 A I R D I S T R I B U T I O N A I R F L O W S O L U T I O N S I n s t a l l a t i o n, O p e r a t i o n, & M a i n t e n a n c e M O D E L Q S T Q u i e t, S e r i e s ( C o n

More information

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN

More information

Controls Analog. Options. Single-Duct Terminal Unit (VCCF, VCWF, and VCEF)

Controls Analog. Options. Single-Duct Terminal Unit (VCCF, VCWF, and VCEF) Options Single-Duct Terminal Unit (VCCF, VCWF, and VCEF) Unit Heat Description Page # Cooling Only EI05 Cooling Only C 4 (VCCF) EI8 Cooling Only With emote Water eheat and Electric eheat - Automatic Dual

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS BY JOHNSON CONTROLS INSTALLATION OPERATION & MAINTENANCE MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS New Release Form ET130.13-NOM4 (908) In conjunction with the use of these instructions, obtain

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

LMHS BASIC UNIT NO CONTROLS

LMHS BASIC UNIT NO CONTROLS JOB NAE ARCHITECT ENGINEER CONTRACTOR OCATION SUBITTA SHEET Form Number TS0000.10 Effective Date 6/08 Replaces Form TS0000.9 BASIC UNIT NO CONTROS CHARTED 'A' DIENSION INCUDES INET ADAPTER PROVIDED ON

More information

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 4 Construction Features... 5 Standard and Optional Features.... 7 Application and

More information

SINGLE DUCT AIR TERMINAL UNITS

SINGLE DUCT AIR TERMINAL UNITS SINGLE DUCT AIR terminal units SINGLE DUCT AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units

More information

Dual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series

Dual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series Product Key UQ Ultra Quiet Product Selection Checklist 1] Select Unit Inlet Size based on control and acoustic parameters.

More information

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L TVBA TVBC TVBF Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVB: LOW POWER CONSUMPTION, ACCESSIBLE

More information

FPV, FDV Series Variable Volume Parallel Flow

FPV, FDV Series Variable Volume Parallel Flow Product Overview Variable Volume/Parallel Flow Fan Powered Terminal s With the variable volume model, the conditioned primary air does not pass through the fan. The primary air section and the recirculating

More information

Electric Furnace KF/KFS Series

Electric Furnace KF/KFS Series Electric Furnace KF/KFS Series KF/KFS 20 20 1 A B C D A: Series B: 20-208V 24-240V 48-480V C: Kilowatts D: 1 or 3-phase Heavy duty open-coil element Direct drive motor Up to 3-speed motor Standard 24 Volt

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS OPTIONS AND ACCESSORIES Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS OPTIONS AND ACCESSORIES Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS OPTIONS AND ACCESSORIES AND REFERENCE INDEX OF SECTIONS Options Overview 2 Hanger Bracket and Inlet Attenuator 4 Insulation Descriptions 5 Access Panels 6 Inlet Flow

More information

SPV / SDV Series SINGLE DUCT TERMINAL UNITS

SPV / SDV Series SINGLE DUCT TERMINAL UNITS SPV / SDV Series SINGLE DUCT Price single duct terminal units are designed to control the airflow rate of conditioned air into an occupied space with minimal pressure drop and low noise levels. An extensive

More information

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS CEW SERIES CEILING EXPOSED HORIZONTL FN COIL UNITS MGIC IRE BMW SERIES FN COILS RE ETLC LISTED IN CCORDNCE WITH UL 1995 ND RE SSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPNY, L.P. 501

More information

Fan Powered Low Profile Variable Volume Terminal Units

Fan Powered Low Profile Variable Volume Terminal Units MANUAL INSTALLATION Fan Powered Low Profile Variable Volume Terminal Units FEVLP / FPVLP / FDVLP Series v001 Issue Date: 07/19/16 07/19/16 Price Industries Limited. All rights reserved. TABLE OF CONTENTS

More information

engineering guide TCS Series Fan-Powered, VAV Terminals

engineering guide TCS Series Fan-Powered, VAV Terminals engineering guide TCS Series Fan-Powered, VAV Terminals FORM 130.13-EG4 (908) TABLE OF CONTENTS Series Fan-Powered, VAV Terminals Features and Benefits....................... 2 Construction Features.......................

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information