Product Data Manual. ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e

Size: px
Start display at page:

Download "Product Data Manual. ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e"

Transcription

1 Product ata Manual ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e

2 Table of Contents Physical ata - Nomenclature Options Effectiveness Performance ata irflow Performance ata Unit imensions Roofcurb imensions Electrical ata Controls ata Options ue to ongoing research and development, Venmar CES Inc. reserves the right to modify specifications and dimensions without prior notice. Page 2

3 - Included in base unit O - Optional N/ - Not vailable Physical ata - Nomenclature Options ERV INOOR UNITS ERV OUTOOR UNITS UNIT NOMENCLTURE OPTIONS 5000i 6500i 8000i 10000i 5000e 6500e 8000e 10000e FROST CONTROL Recirculation O O O O O O O O Exhaust only O O O O O O O O VS frost prevention O O O O O O O O Non defrost VOLTGE/SPEE VC/1/60-1 Speed O O O O O O O O VC/3/60-1 Speed 460 VC/3/60-1 Speed O O O O O O O O 575 VC/3/60-1 Speed O O O O O O O O VC/3/60 - VF O O O O O O O O 460 VC/3/60 - VF O O O O O O O O 575 VC/3/60 - VF O O O O O O O O SENSOR CONTCTS irty filter contacts O O O O O O O O Wheel rotation sensor O O O O O O O O No contacts, no sensor EXTERNL FINISH Galvanized (non painted) Grey paint (galvanized) O O O O O O O O Corrosion resistant O O O O O O O O OUTSIE MPER Non insulated spring return (low leak) O O O O O O O O Insulated spring return (low leak) O O O O O O O O No outside air damper EXHUST MPER Non insulated spring return (low leak) O O O O O O O O Insulated spring return (low leak) O O O O O O O O Gravity backdraft damper (low leak) N/ N/ N/ N/ O O O O No exhaust air damper EXTERNL ISCONNECT Fused disconnect switch O O O O O O O O Non fused disconnect switch O O O O O O O O No disconnect switch HOOS Intake/Exhaust hoods N/ N/ N/ N/ O O O O No hoods OUTSIE INTKE End outside air intake N/ N/ N/ N/ Top outside air intake O O O O N/ N/ N/ N/ Side outside air intake O O O O N/ N/ N/ N/ ottom outside air intake O O O O N/ N/ N/ N/ EXHUST ISCHRGE End exhaust discharge N/ N/ N/ N/ Top exhaust discharge O O O O N/ N/ N/ N/ own exhaust discharge O O O O N/ N/ N/ N/ ISCHRGE End supply discharge Top supply discharge O O O O N/ N/ N/ N/ own supply discharge O O O O O O O O Page 3

4 Physical ata - Nomenclature Options ERV INOOR UNITS ERV OUTOOR UNITS UNIT NOMENCLTURE OPTIONS 5000i 6500i 8000i 10000i 5000e 6500e 8000e 10000e End return air Top return air O O O O N/ N/ N/ N/ Side return air N/ N/ N/ N/ N/ N/ N/ N/ ottom return air O O O O O O O O MEF FILTRTION MEF supply filter O O O O O O O O MEF exhaust filter O O O O O O O O No MEF filtration HEF FILTRTION High efficiency supply filter O O O O O O O O No HEF filtration FREE COOLING Free cooling (enthalpy controller) O O O O O O O O Free cooling (dry bulb) O O O O O O O O No free cooling LOWER ISOLTION Rubber in shear pads isolation Spring blower isolation O O O O O O O O PURGE SECTION Purge section O O O O O O O O No purge section HETING Hot water O O O O O O O O Steam heat O O O O O O O O Hot gas reheat O O O O O O O O Electric heat O O O O O O O O No heating COOLING Chilled water O O O O O O O O x cooling O O O O O O O O No cooling COIL RRNGEMENT Heating, cooling, access section O O O O O O O O Cooling, heating, access section O O O O O O O O Heating, cooling, no access section O O O O O O O O No access section ROOFCUR Insulated roofcurb N/ N/ N/ N/ O O O O No roofcurb - Included in base unit O - Optional N/ - Not vailable Page 4

5 FNS Model Name ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e Supply Type elt drive elt drive elt drive elt drive Wheel Type Forward curved Forward curved Forward curved Forward curved earing all sealed all sealed all sealed all sealed Resilient rings Resilient rings Resilient rings Resilient rings Housing Pillow block Pillow block Pillow block Pillow block Shaft (1) 1" [25mm] 1 3/16" [30mm] 1 7/16" [37mm] 1 7/16" [37mm] Shaft (2) 1" [25mm] 1 3/16" [30mm] 1 3/16" [30mm] 1 7/16" [37mm] Shaft (3) 1" [25mm] Exhaust Type elt drive elt drive elt drive elt drive Wheel Type Forward curved Forward curved Forward curved Forward curved earing all sealed all sealed all sealed all sealed Resilient rings Resilient rings Resilient rings Resilient rings Housing Pillow block Pillow block Pillow block Pillow block Shaft (1) 1" [25mm] 1 3/16" [30mm] 1 7/16" [37mm] 1 7/16" [37mm] Shaft (2) 1" [25mm] 1 3/16" [30mm] 1 3/16" [30mm] 1 7/16" [37mm] Shaft (3) 1" [25mm] Physical ata ENERGY RECOVERY MOULE Model Name ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e Type Wheel Wheel Wheel Wheel Size (Inches) 50 x 6 54 x x x 10 Size [mm] 1,270 x 152 1,372 x 254 1,575 x 254 1,778 x 254 Cassette Size (Inches) 54 x 54 x x 65 x x 73 x x 81 x 20 Cassette Size [mm] 1,372 x 1,372 x 197 1,651 x 1,651 x 508 1,854 x 1,854 x 508 2,057 x 2,057 x 508 Wheel Substrate luminum luminum luminum luminum Wheel Performance Page 6 Page 6 Page 7 Page 7 FILTERS Model Name ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e Type (Primary) MEF MEF MEF MEF Size (Inches) 16 x 25 x 2 16 x 20 x 2 20 x 25 x 2 20 x 24 x 2 20 x 20 x 2 24 x 24 x 2 Size [mm] 406 x 635 x x 508 x x 635 x x 610 x x 508 x x 610 x 51 Number per airstream 4 3 of each size 6 3 of each size Type (Secondary) HEF HEF HEF HEF Size (Inches) 16 x 25 x 4 16 x 20 x 4 20 x 25 x 4 20 x 24 x 4 20 x 20 x 4 24 x 24 x 4 Size [mm] 406 x 635 x x 508 x x 635 x x 610 x x 508 x x 610 x 102 Number per airstream 4 3 of each size 6 3 of each size WEIGHT - INOOR MOELS Model Name ERV5000i ERV6500i ERV8000i ERV10000i Net weight max. 2,950 lbs 4,090 lbs 5,180 lbs 6,600 lbs (without htg/clg option) [1,341 kg] [1,859 kg] [2,355 kg] [3,000 kg] Net weight max. 3,400 lbs 5,205 lbs 6,470 lbs 8,015 lbs (with heating/cooling option) [1,545 kg] [2,366 kg] [2,941 kg] [3,643 kg] WEIGHT - OUTOOR MOELS Model Name ERV5000e ERV6500e ERV8000e ERV10000e Net weight max. 3,250 lbs 4,360 lbs 5,520 lbs 7,020 lbs (without htg/clg option) [1,477 kg] [1,982 kg] [2,509 kg] [3,191 kg] Net weight max. 3,700 lbs 5,475 lbs 6,810 lbs 8,435 lbs (with heating/cooling option) [1,682 kg] [2,489 kg] [3,095 kg] [3,834 kg] Roofcurb Weight 360 lbs 395 lbs 440 lbs 495 lbs [164 kg] [180 kg] [200 kg] [225 kg] Page 5

6 Effectiveness Performance ata Effectiveness irflow (L/s) % % 70% 60% 50% irflow (cfm) ased on equal amounts of outdoor air and return air. Total Effectiveness (Cooling) Sensible Effectiveness (Heating) Latent Effectiveness (Heating) Ratings outside the scope of the HRI Energy Recovery Ventilation Certification Program. ERV5000i/e Model Number: ERW X Type: Wheel Nominal irflow: 3000 scfm Pressure rop: 0.47 inches w.g. Leakage Ratings Pressure Purge ngle ifferential ETR OCF or Setting Test 1: 0.00 inches 4.2% 1.00 N/ Test 2: 0.50 inches 3.6% 1.00 N/ Test 3: 1.00 inches 3.1% 1.00 N/ Thermal Effectiveness Ratings at 0" Pressure ifferential Sensible Latent Total 100% irflow Heating Condition: 73% 67% 70% 75% irflow Heating Condition: 78% 77% 77% 100% irflow Cooling Condition: 72% 61% 65% 75% irflow Cooling Condition: 75% 68% 70% Net Sensible Net Latent Net Total 100% irflow Heating Condition: 73% 67% 70% 75% irflow Heating Condition: 78% 77% 77% 100% irflow Cooling Condition: 72% 61% 65% 75% irflow Cooling Condition: 75% 68% 70% Energy recovery component is certified by HRI to HRI Standard ctual performance in packaged equipment may vary. Effectiveness irflow (L/s) % % 70% 60% 50% irflow (cfm) ased on equal amounts of outdoor air and return air. Total Effectiveness (Cooling) Sensible Effectiveness (Heating) Latent Effectiveness (Heating) Ratings outside the scope of the HRI Energy Recovery Ventilation Certification Program. ERV6500i/e Model Number: HRW Type: Wheel Nominal irflow: 4500 scfm Pressure rop: 0.76 inches w.g. Leakage Ratings Pressure Purge ngle ifferential ETR OCF or Setting Test 1: 0.00 inches 6.5% Test 2: 0.50 inches 1.6% Test 3: 3.00 inches 0.6% Thermal Effectiveness Ratings at 0" Pressure ifferential Sensible Latent Total 100% irflow Heating Condition: 78% 77% 77% 75% irflow Heating Condition: 82% 82% 82% 100% irflow Cooling Condition: 76% 72% 73% 75% irflow Cooling Condition: 80% 77% 78% Net Sensible Net Latent Net Total 100% irflow Heating Condition: 76% 75% 75% 75% irflow Heating Condition: 80% 80% 80% 100% irflow Cooling Condition: 74% 70% 71% 75% irflow Cooling Condition: 78% 75% 76% Energy recovery component is certified by HRI to HRI Standard ctual performance in packaged equipment may vary. Page 6

7 Effectiveness Performance ata Effectiveness irflow (L/s) % % 70% 60% 50% irflow (cfm) ased on equal amounts of outdoor air and return air. Total Effectiveness (Cooling) Sensible Effectiveness (Heating) Latent Effectiveness (Heating) Ratings outside the scope of the HRI Energy Recovery Ventilation Certification Program. ERV8000i/e Model Number: HRW Type: Wheel Nominal irflow: 5900 scfm Pressure rop: 0.76 inches w.g. Leakage Ratings Pressure Purge ngle ifferential ETR OCF or Setting Test 1: 0.00 inches 6.5% Test 2: 0.50 inches 1.5% Test 3: 3.00 inches 0.6% Thermal Effectiveness Ratings at 0" Pressure ifferential Sensible Latent Total 100% irflow Heating Condition: 78% 77% 77% 75% irflow Heating Condition: 82% 82% 82% 100% irflow Cooling Condition: 76% 72% 73% 75% irflow Cooling Condition: 80% 77% 78% Net Sensible Net Latent Net Total 100% irflow Heating Condition: 76% 75% 75% 75% irflow Heating Condition: 80% 80% 80% 100% irflow Cooling Condition: 74% 70% 71% 75% irflow Cooling Condition: 78% 75% 76% Energy recovery component is certified by HRI to HRI Standard ctual performance in packaged equipment may vary. Effectiveness irflow (L/s) % % 70% 60% 50% irflow (cfm) ased on equal amounts of outdoor air and return air. Total Effectiveness (Cooling) Sensible Effectiveness (Heating) Latent Effectiveness (Heating) Ratings outside the scope of the HRI Energy Recovery Ventilation Certification Program. ERV10000i/e Model Number: HRW Type: Wheel Nominal irflow: 7500 scfm Pressure rop: 0.76 inches w.g. Leakage Ratings Pressure Purge ngle ifferential ETR OCF or Setting Test 1: 0.00 inches 6.4% Test 2: 0.50 inches 1.5% Test 3: 3.00 inches 0.6% Thermal Effectiveness Ratings at 0" Pressure ifferential Sensible Latent Total 100% irflow Heating Condition: 78% 77% 77% 75% irflow Heating Condition: 82% 82% 82% 100% irflow Cooling Condition: 76% 72% 73% 75% irflow Cooling Condition: 80% 77% 78% Net Sensible Net Latent Net Total 100% irflow Heating Condition: 76% 75% 75% 75% irflow Heating Condition: 80% 80% 80% 100% irflow Cooling Condition: 74% 70% 71% 75% irflow Cooling Condition: 78% 75% 76% Energy recovery component is certified by HRI to HRI Standard ctual performance in packaged equipment may vary. Page 7

8 irflow Performance ata ERV5000i N EXHUST FLOW PERFORMNCE (NO MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 15"ø - 15" Fan iameter 15"ø - 10" Fan iameter 12"ø - 9" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. ERV5000e N EXHUST FLOW PERFORMNCE (NO MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 15"ø - 15" Fan iameter 15"ø - 10" Fan iameter 12"ø - 9" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. ERV5000i/e EXHUST FLOW PERFORMNCE (WITH MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 15"ø - 15" Fan iameter 15"ø - 10" Fan iameter 12"ø - 9" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. Page 8

9 irflow Performance ata ERV6500i N EXHUST FLOW PERFORMNCE (NO MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 15"ø - 15" Fan iameter 15"ø - 10" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. ERV6500e N EXHUST FLOW PERFORMNCE (NO MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 15"ø - 15" Fan iameter 15"ø - 10" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. ERV6500i/e EXHUST FLOW PERFORMNCE (WITH MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 15"ø - 15" Fan iameter 15"ø - 10" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. Page 9

10 irflow Performance ata ERV8000i N EXHUST FLOW PERFORMNCE (NO MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 18"ø - 18" Fan iameter 18"ø - 13" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. ERV8000e N EXHUST FLOW PERFORMNCE (NO MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 18"ø - 18" Fan iameter 18"ø - 13" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. ERV8000i/e EXHUST FLOW PERFORMNCE (WITH MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP N/ N/ Fan iameter 18"ø - 18" Fan iameter 18"ø - 13" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. Page 10

11 irflow Performance ata ERV10000i N EXHUST FLOW PERFORMNCE (NO MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 20"ø - 18" Fan iameter 18"ø - 18" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. ERV10000e N EXHUST FLOW PERFORMNCE (NO MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 20"ø - 18" Fan iameter 18"ø - 18" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. ERV10000i/e EXHUST FLOW PERFORMNCE (WITH MPER) ESP (in. wg.) irflow (cfm) RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP Fan iameter 20"ø - 18" Fan iameter 18"ø - 18" NOTE: Pressure drops for high efficiency filters and/or heating/cooling coils must be added to fan ESP if they are specified. Standard filtration pressure drop is included in fan performance. Page 11

12 Unit imensions ERV5000i F " [432] EXHUST " [686] OUTSIE 4.563" [116] 3.000" [76] " [432] TOP VIEW " [457] " [2,083] " [559] " * [2,565] C EXHUST OUTSIE " [914] " [965] OUTSIE C " [279] F LEFT VIEW " [305] 3.000" [76] " [533] FRONT VIEW Fan Opening imensions Fan 12"Ø x 9" 15"Ø x 10" " [341] " [403] " [311] " [373] 6.250" [159] 9.500" [241] " [432] 15"Ø x 15" " [403] " [473] " [673] OUTSIE Opening Locations Fan 12"Ø x 9" C* (RIS) " [310] C* (Spring) " [351] " [298] E F " [416] " [340] EXHUST 15"Ø x 10" 15"Ø x 15" " [343] " [343] " [384] " [384] " [332] " [332] " [385] " [335] " [309] " [259] F " [432] * NOTE: imension "C" varies depending upon which "lower Isolation" option is selected; RIS (Rubber In Shear pads isolation) or Spring (spring blower isolation). OTTOM VIEW 3.000" [76] 4.563" [116] " [686] E " [457] " [381] C " [1,651] " [914] C 6.000" [152] E RIGHT VIEW " [305] E " [673] NOTES: imensions in [ ] are millimeters. * dd 38" [965] to standard unit length if heating and/or cooling section is specified. * dd 18" [457] to standard unit length if access section is specified between coils. ccess section must be specified when selecting electric heat with cooling. llow a minimum of 30" [762mm] clearance around unit for maintenance " [241] 6.250" [159] Page 12

13 Unit imensions ERV5000e CONTROL OX CCESS OOR CK VIEW " [2,083] " [838] " [864] " * [2,565] E " [457] " [381] " [1,651] EXHUST HOO OUTOOR INTKE HOO C " [914] 6.000" [152] LEFT VIEW FRONT VIEW RIGHT VIEW " [305] Fan Opening imensions Fan 12"Ø x 9" " [341] " [311] " [432] 9.500" [241] 6.250" [159] 15"Ø x 10" 15"Ø x 15" " [403] " [403] Opening Locations Fan 12"Ø x 9" C* (RIS) " [310] " [373] " [473] C* (Spring) " [351] " [298] E " [416] " [673] NOTES: imensions in [ ] are millimeters. * dd 38" [965] to standard unit length if heating and/or cooling section is specified. * dd 18" [457] to standard unit length if access section is specified between coils. ccess section must be specified when selecting electric heat with cooling. llow a minimum of 30" [762mm] clearance around unit for maintenance. 15"Ø x 10" 15"Ø x 15" " [343] " [343] " [384] " [384] " [332] " [332] " [385] " [335] * NOTE: imension "C" varies depending upon which "lower Isolation" option is selected; RIS (Rubber In Shear pads isolation) or Spring (spring blower isolation). SECTION VIEW E Page 13

14 Unit imensions ERV6500i F " 3.000" [533] [76] 4.563" [116] C EXHUST " [737] " [737] OUTSIE 4.563" [116] 3.000" [76] " [533] E TOP VIEW " [508] " [2,184] " [559] " * [2,870] C EXHUST OUTSIE " [1,016] " [1,016] OUTSIE " [1,905] C " [381] " [381] F 3.000" [76] LEFT VIEW FRONT VIEW " [508] 6.000" [152] Fan Opening imensions Fan 15"Ø x 10" " [403] " [373] 9.500" [241] 6.250" [159] " [533] E 15"Ø x 15" " [403] " [473] " [711] OUTSIE Opening Locations Fan 15"Ø x 10" C* (RIS) " [343] C* (Spring) " [384] " [332] E F " [410] " [334] EXHUST " [711] 15"Ø x 15" " [343] " [384] " [332] " [360] " [284] * NOTE: imension "C" varies depending upon which "lower Isolation" option is selected; RIS (Rubber In Shear pads isolation) or Spring (spring blower isolation). F " [533] 9.500" [241] 6.250" [159] OTTOM VIEW " [508] " [381] C " [1,016] C " [381] E RIGHT VIEW NOTES: imensions in [ ] are millimeters. * dd 38" [965] to standard unit length if heating and/or cooling section is specified. * dd 18" [457] to standard unit length if access section is specified between coils. ccess section must be specified when selecting electric heat with cooling. llow a minimum of 30" [762] clearance around unit for maintenance. Page 14

15 Unit imensions ERV6500e CONTROL OX CCESS OOR CK VIEW " [2,184] " [838] " [864] " * [2,870] E " [508] " [381] " [1,905] EXHUST HOO OUTOOR INTKE HOO C " [1,016] " [381] 6.000" [152] LEFT VIEW FRONT VIEW RIGHT VIEW Fan Opening imensions Fan " [533] 9.500" [241] 6.250" [159] 15"Ø x 10" 15"Ø x 15" " [403] " [403] Opening Locations Fan 15"Ø x 10" C* (RIS) " [343] " [373] " [473] C* (Spring) " [384] " [332] E " [410] " [711] NOTES: imensions in [ ] are millimeters. * dd 38" [965] to standard unit length if heating and/or cooling section is specified. * dd 18" [457] to standard unit length if access section is specified between coils. ccess section must be specified when selecting electric heat with cooling. llow a minimum of 30" [762] clearance around unit for maintenance. 15"Ø x 15" " [343] " [384] " [332] " [360] * NOTE: imension "C" varies depending upon which "lower Isolation" option is selected; RIS (Rubber In Shear pads isolation) or Spring (spring blower isolation). SECTION VIEW E Page 15

16 Unit imensions ERV8000i F " 3.000" [584] [76] 4.563" [116] C EXHUST " [838] " [838] OUTSIE 4.563" [116] 3.000" [76] " [584] E TOP VIEW " [2,362] " [610] " [533] " * [3,124] C EXHUST OUTSIE " [1,067] " [1,067] OUTSIE " [2,235] C " [508] " [508] F 3.000" [76] " [610] 6.000" [152] LEFT VIEW FRONT VIEW Fan Opening imensions Fan 6.250" [159] 9.500" [241] " [584] E 18"Ø x 13" 18"Ø x 18" " [479] " [479] " [441] " [556] " [813] OUTSIE Opening Locations Fan 18"Ø x 13" C* (RIS) " [387] C* (Spring) " [429] " [376] E F " [414] " [351] EXHUST " [813] 18"Ø x 18" " [387] " [429] " [376] " [357] " [294] * NOTE: imension "C" varies depending upon which "lower Isolation" option is selected; RIS (Rubber In Shear pads isolation) or Spring (spring blower isolation). F " [584] OTTOM VIEW 9.500" [241] 6.250" [159] C " [610] " [406] C " [1,067] E " [508] RIGHT VIEW NOTES: imensions in [ ] are millimeters. * dd 38" [965] to standard unit length if heating and/or cooling section is specified. * dd 18" [457] to standard unit length if access section is specified between coils. ccess section must be specified when selecting electric heat with cooling. llow a minimum of 30" [762] clearance around unit for maintenance. Page 16

17 Unit imensions ERV8000e CONTROL OX CCESS OOR CK VIEW " [2,362] " [965] " [1,016] " * [3,124] " [2,235] EXHUST HOO OUTOOR INTKE HOO 6.000" [152] LEFT VIEW FRONT VIEW Fan Opening imensions Fan " [584] 18"Ø x 13" " [479] " [441] 18"Ø x 18" " [479] " [556] Opening Locations Fan 18"Ø x 13" C* (RIS) " [387] C* (Spring) " [429] " [376] E " [414] 18"Ø x 18" " [387] " [429] " [376] " [357] * NOTE: imension "C" varies depending upon which "lower Isolation" option is selected; RIS (Rubber In Shear pads isolation) or Spring (spring blower isolation). SECTION VIEW 9.500" [241] " [813] C 6.250" [159] E E " [610] " [406] " [1,067] " [508] RIGHT VIEW 6.000" [152] NOTES: imensions in [ ] are millimeters. * dd 38" [965] to standard unit length if heating and/or cooling section is specified. * dd 18" [457] to standard unit length if access section is specified between coils. ccess section must be specified when selecting electric heat with cooling. llow a minimum of 30" [762] clearance around unit for maintenance. Page 17

18 Unit imensions ERV10000i F " 3.000" [737] [76] 4.563" [116] C EXHUST " [864] " [864] OUTSIE 4.563" [116] 3.000" [76] " [737] E TOP VIEW " [2,565] " [660] " [635] " * [3,531] " [660] " [356] C EXHUST OUTSIE " [1,270] " [1,270] OUTSIE " [2,286] C " [1,270] " [470] " [470] C C " [470] F 3.000" [76] " [660] 6.000" [152] E LEFT VIEW FRONT VIEW RIGHT VIEW Fan Opening imensions Fan 18"Ø x 18" 20"Ø x 18" " [479] " [629] Opening Locations Fan 18"Ø x 18" C* (RIS) " [387] " [556] " [578] C* (Spring) " [429] " [376] E F " [408] " [345] 9.500" [241] " [838] OUTSIE EXHUST " [737] E " [838] NOTES: imensions in [ ] are millimeters. * * dd 38" [965] to standard unit length if heating and/or cooling section is specified. dd 18" [457] to standard unit length if access section is specified between coils. ccess section must be specified when selecting electric heat with cooling. llow a minimum of 30" [762] clearance around unit for maintenance. 20"Ø x 18" " [410] " [451] " [398] " [397] " [333] F " [737] 6.250" [159] 9.500" [241] * NOTE: imension "C" varies depending upon which "lower Isolation" option is selected; RIS (Rubber In Shear pads isolation) or Spring (spring blower isolation). OTTOM VIEW Page 18

19 Unit imensions ERV10000e CONTROL OX CCESS OOR CK VIEW " [2,565] " [1,041] " [1,118] " * [3,531] " [2,286] EXHUST HOO OUTOOR INTKE HOO C 6.000" [152] LEFT VIEW FRONT VIEW Fan Opening imensions Fan " [737] 9.500" [241] 6.250" [159] 18"Ø x 18" 20"Ø x 18" " [479] " [629] " [556] " [578] " [838] Opening Locations Fan 18"Ø x 18" C* (RIS) " [387] C* (Spring) " [429] " [376] E " [408] E 20"Ø x 18" " [410] " [451] " [398] " [397] * NOTE: imension "C" varies depending upon which "lower Isolation" option is selected; RIS (Rubber In Shear pads isolation) or Spring (spring blower isolation). SECTION VIEW E " [660] " [356] " [1,270] " [470] RIGHT VIEW 6.000" [152] NOTES: imensions in [ ] are millimeters. * dd 38" [965] to standard unit length if heating and/or cooling section is specified. * dd 18" [457] to standard unit length if access section is specified between coils. ccess section must be specified when selecting electric heat with cooling. llow a minimum of 30" [762] clearance around unit for maintenance. Page 19

20 Roofcurb imensions INSULTE ROOFCUR Exhaust ir Hood Side X L Roofcurb etail 4 2" [51mm] " [457mm] Exterior Wall Interior Wall W See Roofcurb etail 2" 2" [51mm] [51mm] imensions ERV5000e ERV6500e ERV8000e ERV10000e L* *Roofcurb length is determined by subtracting 6" [152] from the unit length (not including hoods). W Roofcurb width is determined by subtracting 6" [152] from the unit width. X 46.0" [1,168] 52.0" [1,321] 57.0" [1,448] 65.0" [1,651] L*: Remember to add 38" [965] to standard unit length if heating and/or cooling section is specified EFORE subtracting 6" [152] for roofcurb length. Remember to add 18" [457] to standard unit length if access section is specified between coils EFORE subtracting 6" [152] for roofcurb length. Roofcurb Weight ERV5000e ERV6500e ERV8000e ERV10000e 315 lbs [143 kg] 345 lbs [156 kg] 375 lbs [170 kg] 415 lbs [188 kg] NOTE: imensions shown in [ ] are millimeters. Item/escription 1 - Galvanized Steel Exterior Wall 2 - Galvanized Steel Interior Wall 3-2" [51] Insulation 4 - Galvanized Steel Stiffener NOTE: The quantity of stiffeners provided will vary depending on the unit size. General Note: The roofcurb is shipped in pieces and requires assembly on the jobsite. Page 20

21 Electrical ata OP MOTOR HIGH EFFICIENCY 208/1/60 230/1/60 208/3/60 230/3/60 460/3/60 575/3/60 Motor HP FL MC MOP FL MC MOP FL MC MOP FL MC MOP FL MC MOP FL MC MOP N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ NOTE: Electrical data may change depending on options selected (this data includes fan, wheel motors and base price electrical options). oes not include an electric heater, if selected. MC/MOP Selection With ifferent Size Supply nd Exhaust Motors MC for different motor HP: 1) Select the MC for each motor HP. 2) dd the two numbers together and divide by 2. 3) The result is the new actual MC value. MOP for different motor HP: 1) Select the MOP for each motor HP. 2) dd the two numbers together and divide by 2. 3) From the resultant calculated MOP value, select the next smallest value of protection from the Standard Overcurrent Protection chart below to get the actual MOP value. Example: 460/3/60 MC MOP 2 HP motor HP motor Total ivide by 2 Real value ctual value NOTE: This method gives approximate electrical data. Please consult Venmar Select Software or the factory for exact values. Standard Overcurrent Protection Page 21

22 Controls ata Sequence of Operation efore start-up, check the unit for obstructive packaging, objects near or in blowers, dampers, enthalpy wheel, etc. Once installation is complete, check all modes of operation to ensure that the unit is working properly. Close the doors and check for operation in all modes. Ventilation Control Venmar CES has a remote wall controller that is compatible with the unit control box for outdoor models. Power connected, no ventilation call. oth fans are off, frost control damper (if equipped) closes off fresh air from outside. External hood dampers (if equipped) are closed. Power connected, low speed call (if equipped). oth fans are on low speed, internal frost control damper (if equipped) closes recirculation opening. External hood dampers (if equipped) are open. If unit is single speed, it will come on that speed on a call for low or high. Power connected, high speed call. oth fans on high speed, frost control damper (if equipped) closes recirculation opening. External hood dampers (if equipped) are open. If unit is single speed, it will come on that speed on a call for low or high. Occupied Timer/Sensor Power connected, occupied timer/sensor connection open (unoccupied mode). oth fans are off, frost control damper (if equipped) opens recirculation opening. External hood dampers (if equipped) are closed. Free Cooling Power connected, enthalpy control contacts closed, unit ventilating. The wheel stops rotating, fans stay on set speed, frost control damper (if equipped) is closed. Fan Interlock When connecting the energy recovery ventilators to the existing ductwork system of an air handler, typically the air handler should be running whenever the ventilator is running. To achieve this combination there is a set of contacts in the control box which close when the ventilator is running. ERV Control Wiring low voltage remote control wiring interface is provided on the outdoor units. The connections are made through the bottom panel, roofcurb and roof opening. The low voltage remote wiring terminal is located inside the unit on the control box. Installer must provide wiring for the optional controls that may be supplied. ll field installed low voltage wiring must be Class II. Remote Wall Control Optional wall control requires 18 gauge wires (or equivalent). This remote wall control runs on 24 VC. Low Voltage Control ll other terminals are 24 VC or dry contact control. Low voltage terminal control consists of the following: Occupied Timer/Sensor 24 VC, needs dry contact to operate. Remote Fan Control (control wiring option) 24 VC, requires single pole, double throw switch. irty Filter Sensor Makes dry contact. Low Temperature Control (control wiring option) Makes dry contact. Wheel Rotation Sensor Makes dry contact. CO 2 Ventilation Control (control wiring option) Makes dry contact. Unoccupied Recirc Contacts Makes dry contact. Smoke etector (control wiring option) Makes dry contact. The remote wall controls work with the integrated controls within the unit to control the ventilation sequence. Without the wall control, fans can be operated with the dry contacts or a switch. Page 22

23 Controls ata Occupied Timer/Sensor Occupancy control is achieved by connection to a terminal provided either in the unit control box or the wall remote panel. This terminal requires a dry contact which could be provided by various controls such as a timer, occupancy sensor, building management system or other. Enthalpy Control Energy Recovery Ventilators (ERVs) can be controlled by an enthalpy controller that switches between free cooling and /C unit cooling. When free cooling is possible, the ERV will ventilate without energy recovery (the enthalpy wheel stops) on a call for cooling. The ventilation rate is not affected. rybulb temperature free cooling is achieved by reading the outside air temperature and setting the thermostat for the range of temperature where free cooling is required (factory set between 68 F and 80 F [20 C and 27 C]). Setpoint enthalpy control free cooling is achieved by using an enthalpy controller reading the outside air temperature and humidity (this setpoint is field adjustable). Remote Fan Control Remote fan control can be achieved by connecting dry contact controls to the terminal interface provided in the unit control box. These controls can be the following: CO 2 sensor, timer, building management system, SPT switch, etc. irty Filter Sensor ERVs can be equipped with dirty filter sensors which monitor the pressure across the filters and close the contacts when the filters become restricted with dirt. Venmar CES provides an alarm light to signal dirty filters on unit control box or wall remote panel. CO 2 Ventilation Control ERVs can be controlled by a CO 2 controller that dictates fan speed based on CO 2 levels. s CO 2 levels increase, fan speed is raised for increased ventilation. Wheel Rotation Sensor ERVs can be equipped with a wheel rotation sensor option. If the wheel rotation stops (unless in enthalpy state, defrost mode or unoccupied condition), an alarm signal will be activated. The alarm is used to turn on an alarm light installed in the control box or the remote wall panel. The wheel rotation sensor board has jumpers that can be used to set the time duration (1, 2, 4 or 8 minutes) for the alarm to be activated after wheel failure occurs. Unoccupied Recirc Contacts On recirc defrost units, an unoccupied recirc control can be achieved by connection to the terminal provided in the control box. These terminals require a dry contact which could be provided by a timer, thermostat or other. Closure of these terminals will cause the unit to go into a 'recirc mode' where the supply fan runs on high speed and the exhaust fan stops. Smoke etector ERVs can be equipped with a duct-mount smoke detector which will monitor the air when passing through the duct system into the ERV. When sufficient smoke is detected, an alarm condition is activated and will open the auxiliary contact to stop operation of the ERV. The smoke detector should be located in a normally occupied area of premises. It is recommended for compliance to IMC Code 606 and NFP-90. Page 23

24 Options Frost Control Recirculation efrost Recirculation defrost is a temperature initiated time-based cycle which will de-energize the exhaust fan and the wheel drive motor, close the outdoor air damper and circulate return air through both sides of the wheel. If recirculation defrost is in operation, it will recirculate approximately 15% of the time, only when the outdoor air temperature falls below 15 F [-9 C]. Please note that if the indoor relative humidity is expected to be 30% or less, please contact the factory as frost control may not be required at all. Exhaust Only efrost Exhaust only defrost is a temperature initiated time-based cycle which will de-energize the supply fan, close the outdoor air damper and exhaust return air through the exhaust side of the wheel as it continues to rotate. If exhaust only defrost is in operation, the supply fan will be shut off approximately 15% of the time, only when the outdoor air temperature falls below 15 F [-9 C]. Please note that if the indoor relative humidity is expected to be 30% or less, please contact the factory as frost control may not be required at all. Recirculation and Exhaust Only efrost Table efrost/ventilation ERV Type of Initiation (Minutes) Model Stage efrost Temperature efrost Time/Run Time 5000 to 1 E 15 F -9 C 12/ E -5 F -21 C 12/ to 1 R 15 F -9 C 12/ R -5 F -21 C 12/12 Legend: R - Recirculation E - Exhaust Only Variable Speed rive (VS) Frost Prevention Variable speed frost prevention is based on an exhaust air temperature and is controlled by a C controller. If this temperature reaches the factory setpoint of 33 F [1 C] (adjustable), the frost control cycle begins. The controller modulates the total energy wheel rotation speed to maintain the exhaust air temperature above its setpoint and prevent frost formation on the enthalpy wheel. Contact the factory for the relation between the wheel effectiveness and wheel rotation speed. Motors, Voltage and Speeds Venmar CES standard HP motors meet the Energy Policy ct (EPCT) of the United States and Canada's Energy Efficiency Regulation (EER). ll ERVs have numerous voltage options to choose from. See the Physical ata - Nomenclature Options chart on page 3 for specific voltage availability. Standard belt driven units come in one speed. s an option for the ERV units, Venmar CES offers Variable Frequency rives (VFs) to allow variable speeds for either the supply or exhaust motors (3 phase voltage only). The VF is keypad programmable and therefore allows the user to change the desired motor speeds or use custom settings and preferences. Standard in all VFs are wiring terminals that enable VF circuit and operation control by field wired relays, sensors or external devices volt control signal for the VFs is provided by others in the field. To guarantee that the user will have accurate and individual motor control, each motor has a separate VF on the applicable circuit. lso, for 575 volt, line reactors are installed to protect the VF and motor. irty Filter Sensor The dirty filter sensor option will monitor the pressure across the filters and will close contacts when dirt restricts the airflow to the setpoint. The connections at the external terminal interface will close and can be used to control a remote light or alarm to signal dirty filters. The sensor has the following features: Pressure setpoint is factory set (adjustable). Polyester film diaphragm responds to pressure changes as low as 2.5mm WC. Equipped with male quick connect terminals. Wheel Rotation Sensor The wheel rotation sensor is optional. If the wheel stops rotating for any reason, the dry contacts on the sensor will close. These contacts can be wired to a light, an alarm or building management system. See wiring diagram on unit control box cover for sensor contact location. External Finish - Paint Indoor and outdoor units use satincoat-finished galvanized steel with grey air-dried enamel paint. corrosion resistant paint finish (withstanding 1,000 hours of salt spray as per STM -117) is also available. ampers amper options are available in power open/spring closed. Gravity ackdraft amper ampers have the following features: Extruded aluminum damper frame is not less than 0.060" [2mm] in thickness and is 2.5" [64mm] deep. lades are extruded aluminum profiles. lade gaskets and side seals are extruded silicone. Gaskets are secured in integral slots within aluminum extrusions. earing system is composed of celcon bearings rotating on zinc-plated 1/2" [13mm] steel pivot points. Linkage system consists of hard alloy aluminum crankarms fastened to zinc-plated steel pivot rods and doubly secured within channel running along top of blade. Large diameter hard alloy aluminum linkage rod connects the crankarms by means of a zinc-plated steel trunnion. Cup point trunnion screw allows for a penetrating grip of the linkage rod. Trunnions are zinc-plated to provide a hard, smooth and long-lasting rotating surface. ampers are designed for operation in temperatures ranging between -40 F and 212 F [-40 C and 100 C]. ir leakage through a 24" x 24" [610 x 610mm] damper does not exceed 20 cfm/sq.ft. against 1" wg. differential static pressure at standard air. Non Insulated Motorized ampers have the following features: Extruded aluminum damper frame is not less than 0.080" [2mm] in thickness and is 4" [102mm] deep. lades are extruded aluminum profiles. lade gaskets are extruded EPM elastomer. Frame seals are extruded TPE thermoplastic. Gaskets are secured in an integral slot within the aluminum extrusions. Page 24

25 Options earings are comprised of a celcon inner bearing fixed to a 7/16" [11mm] aluminum hexagon blade pin rotating within a polycarbonate outer bearing inserted in the frame, resulting in no metal-to-metal or metal-to-plastic contact. Linkage hardware is installed in frame side and constructed of aluminum and corrosion resistant, zinc and nickel plated steel, complete with cup-point trunnion screws for a slip-proof grip. ampers are designed for operation in temperatures ranging between -40 F and 212 F [-40 C and 100 C]. ir leakage through a 48" x 48" [1220 x 1220mm] damper does not exceed 10.3 cfm/sq.ft. against 4" wg. differential static pressure at standard air. Standard air leakage data is certified under the MC Certified Ratings Program. Pressure drop of a fully open 48" x 48" [1220 x 1220mm] damper does not exceed 0.02" wg. at 1000 fpm. Insulated Motorized ampers have the following features: Extruded aluminum damper frame is not less than 0.080" [2mm] in thickness and is 4" [102mm] deep and is insulated with polystyrene. lades are extruded aluminum profiles, internally insulated with non-cfc, expanded polyurethane foam and thermally broken. Complete blade has an insulating factor of R-2.29 and a temperature index of 55. lade gaskets are extruded EPM elastomer. Frame seals are extruded TPE thermoplastic. Gaskets are secured in an integral slot within the aluminum extrusions. earings are comprised of a celcon inner bearing fixed to a 7/16" [11mm] aluminum hexagon blade pin rotating within a polycarbonate outer bearing inserted in the frame, resulting in no metal-to-metal or metal-to-plastic contact. Linkage hardware is installed in frame side and constructed of aluminum and corrosion resistant, zinc and nickel plated steel, complete with cup-point trunnion screws for a slip-proof grip. ampers are designed for operation in temperatures ranging between -40 F and 212 F [-40 C and 100 C]. ir leakage through a 48" x 48" [1220 x 1220mm] damper does not exceed 10.3 cfm/sq.ft. against 4" wg. differential static pressure at standard air. Standard air leakage data is certified under the MC Certified Ratings Program. ir leakage does not exceed 6.7 cfm/sq.ft. against 4" w.g. differential static pressure at -40 F [-40 C]. Pressure drop of a fully open 48" x 48" [1220 x 1220mm] damper does not exceed 0.03" wg. at 1000 fpm. External isconnect ll disconnects are factory installed. Fused or non-fused disconnects can be ordered. Hoods ll rooftop ERVs are available with outside air (O..) intake hoods and exhaust air (E..) outlet hoods. The E.. hoods help the exhaust fan with static regain for better airflow performance. The hoods also help keep debris and small animals from entering into the ERV unit. Hoods are weather and water resistant. Fan ischarge/return ir Options S.. - Supply ir Opening R.. - Return ir Opening For more detailed dimensions refer to dimensional data, pages 12 to 19. Filtration Venmar CES uses only the highest quality disposable Medium Efficiency Filters (MEF) with 35% ust Spot Efficiency (SE) as the standard option. Venmar CES also offers a high efficiency filter with an 80-85% SE rating. When using MEF filtration for both airstreams of the enthalpy wheel, a clean functional wheel with no reduction in wheel performance is ensured. Venmar CES recommends MEF filtration with all ERVs for optimum wheel performance. The following pressure drops are to be added to the ESP if high efficiency filters are specified. irflow Pressure rop Model (cfm) (in. wg.) ERV ERV ERV ERV Enthalpy Control - Free Cooling ERV units can be controlled by an enthalpy controller that switches between free cooling and /C unit cooling. When free cooling is possible, the ERV will ventilate without energy recovery (the enthalpy wheel stops) on a call for cooling. The ventilation rate is not affected. If the unit is not operating, enthalpy control contact will initiate low speed ventilation. The enthalpy control must be connected in conjunction with a cooling thermostat control to prevent free cooling from initiating in heating seasons. Enthalpy options can be temperature, setpoint enthalpy or differential enthalpy controlled. Enthalpy control options are factory mounted to the control terminals on the energy recovery ventilator. If the unit is ventilating, the enthalpy wheel will stop rotating upon control contact closure. Page 25

26 Temperature Controller (rybulb Setpoint) This simple temperature controller is used to free cool based on sensible energy alone. This controller has the following features: djustable differential setting: 3 F to 10 F [1.7 C to 5.6 C]. Operating scale range: 0 F to 100 F [-18 C to 38 C]. mbient temperature compensated. Solid State Enthalpy Controller (Setpoint Enthalpy) This controller maximizes the use of free outdoor air in place of the first stage of cooling in HVC economizer systems. It has the following features: Provides accurate solid state enthalpy change over control. Enthalpy setpoint (,,C,) is used to select combination of air temperature and humidity that is suitable for free cooling. Solid State Enthalpy Sensor (ifferential Enthalpy) For differential enthalpy control, a separate solid state enthalpy sensor is required along with the solid state enthalpy controller. The enthalpy controller monitors the outdoor air enthalpy and the enthalpy sensor monitors the return air enthalpy. The differential between the two airstreams is used as the primary condition for controlling the free cooling operation of the unit. This enthalpy sensor has the following features: Senses and combines temperature and humidity of outdoor air. Long lasting solid state sensing element is accurate and stable over time. lower Isolation ll fan packages are isolated for smooth and vibration-free operation. This type of operation helps to keep noise levels at a minimum. ll fractional HP and nominal HP fan packages use rubber isolation as the standard base option. Spring vibration isolators (1" [25mm] deflection) are also available. Purge Section Venmar CES offers an adjustable purge section for the ERVs. The purge section is adjustable but is factory set based on pressure differential. If you have to field adjust the purge, simply loosen the two set screws, pivot the purge to the desired angle and re-fasten the set screws. The following diagram describes how to calculate the prescribed differential for the system and ERV layout. O.. E.. P o/a P r/a damper 0.05 filter ESP R.. = 0.5" ESP P o/a = Static pressure on the outside air side of the enthalpy wheel P r/a = Static pressure on the return air side of the enthalpy wheel S.. Page 26 Options o the following operation carefully noting if the pressure is negative/positive. Formula: P o/a - P r/a (before the wheel on both sides: see ) Example: P o/a = P r/a = Suction = P o/a - P r/a = (-1.00) = 0.45 Pressure ifferential Using the results from the pressure differential calculation, refer to the table that follows for the purge airflow. Pressure Purge ifferential (cfm) NOTE: Purge flows are approximate values for fan selection only. Purge O.. O.. + C.. Heating Heating options are available; see the Heating Coils section for more detailed information (Pages 27-29). Cooling Cooling options are available; see the Cooling Coils section for more detailed information (Pages 30-33). Coil rrangement Venmar CES offers different coil arrangements for the ERV units depending on the unit utilization. The first option includes the heating coil then the cooling coil with an access section in between the coils. The second option includes the cooling coil then the heating coil with an access section between the coils. The third option includes the heating coil then the cooling coil without an access section between the coils. The last option is to have no access section, this option is for units with one coil or no coils. E.. Rotation O.. Exhaust fan pulls a portion of O.. through the wheel, purging wheel carryover and exhaust air to outside. O.. - Outside ir E.. - Exhaust ir C.. - Carryover ir

Product Data Manual. HRV600i HRV700i HRV1200i HRV2000i/e. HRV2000e

Product Data Manual. HRV600i HRV700i HRV1200i HRV2000i/e. HRV2000e Product Data Manual HRV600i HRV700i HRV1200i HRV2000i/e HRV2000e Table of Contents Physical Data - Nomenclature Options............................................. 3 Effectiveness Performance Data.................................................

More information

ERV. Energy Recovery Ventilators. Capacity: 400 to 4,000 cfm Model: ERV500i/e, ERV1000i, ERV1500i/e, ERV2000i/e, ERV3000i/e

ERV. Energy Recovery Ventilators. Capacity: 400 to 4,000 cfm Model: ERV500i/e, ERV1000i, ERV1500i/e, ERV2000i/e, ERV3000i/e ERV Energy Recovery Ventilators Installation, Operation and Maintenance Instructions Manual Capacity: 400 to 4,000 cfm Model: ERV500i/e, ERV1000i, ERV1500i/e, ERV2000i/e, ERV3000i/e 2013 Venmar CES Inc.

More information

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow. NU1030 HRV Specifications Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

More information

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow. NU2540 ERV Specifications Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

More information

A. NU2035 HRV Specifications NU2035

A. NU2035 HRV Specifications NU2035 A. NU2035 HRV Specifications NU2035 B. Available Options CUSTOMIZATION: This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details

More information

SPECIFICATION SHEET. C5000 ( cfm)

SPECIFICATION SHEET. C5000 ( cfm) (3500 5500 cfm) CASING Double wall cabinet White exterior paint, 22GA steel Galvanized 18GA steel inner wall Access door with ¼ turn handle Insulation : 2 in 18GA Stainless Steel drain pan Drain connection

More information

ERV Series. Submittal Data *LC994* Models 60Hz - HFC-410A LC971

ERV Series. Submittal Data *LC994* Models 60Hz - HFC-410A LC971 ERV Series Submittal Data Models 60Hz - HF-410 *L994* L971 Rev.: November 18, 16 Table of ontents ERV Series Unit Features 4 ERV Series Nomenclature 6 Product pplications 7 ERV Unit Effectiveness & HRI

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICL GUIDE SPLIT-SYSTEM EVPORTOR LOWERS K*ES120 10 NOMINL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling coil

More information

Installation, Operation and Maintenance Instructions. ERV1500e ERV2000e ERV3000e

Installation, Operation and Maintenance Instructions. ERV1500e ERV2000e ERV3000e Installation, Operation and Maintenance Instructions ERV500e ERV000e ERV000e ERV000e ERV500e ERV000e Table of Contents Safety Considerations..................................................................

More information

Industrial Fans & Blowers

Industrial Fans & Blowers Industrial Fans & lowers UVL IRECT RIVE UPLST Low silhouette weatherproof closure for vertical air discharge irect drive, low maintenance erodynamically efficient performance TEFC industrial duty motor

More information

CH5000 Heat Recovery Ventilator

CH5000 Heat Recovery Ventilator ADVANCED COMMERCIAL Heat Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 3500-5500 CFM CASING Double-wall cabinet White exterior paint, 22-gauge galvanized steel -gauge

More information

Industrial Fans & Blowers

Industrial Fans & Blowers Industrial Fans & lowers ROOF VENTILTORS UVL IRECT RIVE UPLST ROOF VENTILTORS FETURES & ENEFITS Low silhouette weatherproof closure for vertical air discharge irect drive, low maintenance erodynamically

More information

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators Version: Dec. 01, 2004 RERV & RERVX Rotary Energy Recovery Ventilators Indoor and Outdoor Installations 250 20,000 CFM Capacities RERVLP Low Profile Indoor Rotary Energy Recovery Ventilators Ideal for

More information

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION P R O D U C T S P E C I F I C AT I O N S I N D O O R A I R Q U A L I T Y ERV ENERGY RECOVERY VENTILATOR 60 HZ Bulletin No. 20245 March 200 Supersedes April 2009 Indoor / Outdoor 500 to 0,000 cfm Capacity

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions 62MB,MC,MD,ME040-950 Energy Recovery Ventilators Installation, Start-Up and Service Instructions CONTENTS Page SFETY CONSIDERTIONS...1 INTRODUCTION...1 INSTLLTION... 1-58 Step 1 Inspection...1 Step 2 Install

More information

ERU ENERGY RECOVERY UNIT

ERU ENERGY RECOVERY UNIT TECHNICAL GUIDE ERU ENERGY RECOVERY UNIT TGERU-1 Energy Recovery Technical Guide When you need outside air that s clean and dry, Sierra delivers. When you need that same performance each and every day

More information

Ceiling and Inline Fans

Ceiling and Inline Fans Ceiling and Inline Fans Page Introduction.....................................2 Construction Features..............................3 Specifications and Dimension Data GC 122-184....................................4

More information

HRV. Heat Recovery Ventilators. Capacity: 300 to 1,260 cfm Model: HRV600i, HRV700i, HRV1200i

HRV. Heat Recovery Ventilators. Capacity: 300 to 1,260 cfm Model: HRV600i, HRV700i, HRV1200i HRV Heat Recovery Ventilators Installation, Operation and Maintenance Instructions Manual Capacity: 300 to,0 cfm Model: HRV00i, HRV700i, HRV00i 00 Venmar CES Table of Contents Nomenclature...3 Safety Considerations...

More information

ENERGY RECOVERY SYSTEM 60 HZ

ENERGY RECOVERY SYSTEM 60 HZ I N D O O R A I R Q U A L I T Y E N G I N E E R I N G D A T A ENERGY RECOVERY SYSTEM 60 HZ Bulletin No. 210517 April 2008 Supersedes 210368 April 2007 300 to 6200 cfm Capacity MODEL NUMBER IDENTIFICATION

More information

Factory Option Codes L M E S P R D V F F H E

Factory Option Codes L M E S P R D V F F H E I N D O O R A I R Q U A L I T Y P R O D U C T S P E C I F I C AT I O N S ENERGY RECOVERY SYSTEM FOR L-SERIES ROOFTOP UNITS - 60 HZ Bulletin No. 10533 January 011 Supersedes October 010 800 to 600 cfm Capacity

More information

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6) ENGINEERING DT PCKGED HET PUMPS CHP16 024 030 036 048 060 CHP20 036 048 060 2 to 5 Ton (7.0 to 17.6 ) SEER up to 12.65 Net Capacity 23,800 to 59,000 Btuh (7.0 to 17.3 ) Heating Capacity 23,800 to 56,000

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

CHP20R Basic Unit CHP

CHP20R Basic Unit CHP ENGINEERING DT PCKGED HET PUMPS CHP20R ELITE SERIES RESIDENTIL 2 to 5 Ton (7.0 to 17.6 ) SEER up to 12.65 Net Capacity 24,000 to 59,000 Btuh (7.0 to 17.3 ) Heating Capacity 24,200 to 56,000 (7.1 to 16.4

More information

KITCHEN VENTILATION SOLUTIONS

KITCHEN VENTILATION SOLUTIONS KITHN VNTILTION SOLUTIONS HOO LINRS XHUST NS SILNRS IMPROVING INOOR IR QULITY THROUGH TTR VNTILTION June 0 SK00 www.fantech.net KITHN VNTILTION SOLUTIONS Today s kitchens have become much more than a place

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

D F B. DFBH Rooftop Unit DFBV

D F B. DFBH Rooftop Unit DFBV SYSTEM, UAL LOWER MOEL H Rooftop Unit V ive Sizes H - Horizontal Configuration with ull Curb Cap ase and either Horizontal or Vertical (down) ischarge V - Vertical Configuration with Horizontal ischarge,

More information

Centrifugal Inline Fans

Centrifugal Inline Fans Centrifugal Inline Fans Models SQ-M and SQ-M Direct and elt Drive UILDING VLUE IN IR. February January 2018 2017 Models SQ-M & SQ-M Centrifugal Square Inline Duct Fans Designed for indoor and outdoor clean

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Americraft is dedicated to assist you, our customer, in all aspects of your air moving requirements.

Americraft is dedicated to assist you, our customer, in all aspects of your air moving requirements. mericraft Manufacturing Company Inc. has been manufacturing quality industrial fans and ventilation products since 1946. Our 50+ years of proven experience, strong national reputation and excellent customer

More information

MOUNTING ARRANGEMENT OPTIONS OVERVIEW

MOUNTING ARRANGEMENT OPTIONS OVERVIEW ELT DRIVE SIDEWLL PROPELLER FNS MOUNTING RRNGEMENT OPTIONS OVERVIEW Page Mounting rrangement Description 2-3 Housing Heavy-gauge, all galvanized G-90 steel housing provides a simple solution to installing

More information

MODEL COMPARISON MOUNTING ARRANGEMENT OPTIONS

MODEL COMPARISON MOUNTING ARRANGEMENT OPTIONS LINE OVERVIEW S&P s Direct Drive Sidewall Propeller Fan line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models

More information

BAC, BAF, BAH Central Station Air Handlers

BAC, BAF, BAH Central Station Air Handlers PRODUCT DATA & INSTALLATION Bulletin B80-BA-PDI-5 Part # 1097717 PRODUCT SUPPORT web: b-rp.ca/bah email: ahu@b-rp.ca call: 1-844-893-3222 x527 scan: BAC, BAF, BAH Central Station Air Handlers Indoor and

More information

Energy Recovery Ventilator

Energy Recovery Ventilator Energy Recovery Ventilator Page Introduction............................................2 Direct Drive Standard Construction Features..................3 Belt Drive Standard Construction Features...................4

More information

MODELS LCE/LCS, L2E/L2S, L3E/L3S

MODELS LCE/LCS, L2E/L2S, L3E/L3S LINE OVERVIEW S&P s Belt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With levels of construction, the belt drive models are for

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

AIR-AIR ENERGY CONSERVATION MODULE

AIR-AIR ENERGY CONSERVATION MODULE AIR-AIR ENERGY CONSERVATION MODULE BC-ECW SERIES INDOOR/OUTDOOR INSTALLATION MANUFACTURED BY TABLE OF CONTENTS BC-ECW - Description...3 Components and fabrication details...3-4 Frost prevention & selection

More information

MODELS LCE/LCS, L2E/L2S, L3E/L3S

MODELS LCE/LCS, L2E/L2S, L3E/L3S ELT DRIVE SIDEWLL PROPELLER FNS LINE OVERVIEW Jenco s elt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 levels of construction,

More information

Direct Gas-Fired Make-up Air Heaters

Direct Gas-Fired Make-up Air Heaters Direct Gas-Fired Make-up Air Heaters SDM-E SERIES OUTDOOR SPECIFICATIONS MANUAL MANUFACTURED BY : BROTHERS LIMITED TABLE OF CONTENTS Summary description of the unit...4 Required burner capacity...6 Dimensions

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

Fan-Powered Parallel

Fan-Powered Parallel Table of Contents Service Model Number Description FPP 2 Selection Procedure FPP 3 5 General Data Valve/Controller Guidelines FPP 6 Performance Data ir Pressure Requirements FPP 7 8 Performance Data Fan

More information

200, 9200 & 9200-VIB SERIES

200, 9200 & 9200-VIB SERIES DUCT VENTILATION 200 SERIES Indoor Applications, Insulated or Non-Insulated 9200 SERIES Heavy duty, Insulated Indoor or Outdoor Applications SUBJECT TO CHANGE WITHOUT NOTICE - 04/7 Optional motor, drive

More information

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER) 511.06-TG3Y (0600) SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS B1CH 1 & 40 15 and 0 NOMINAL TONS (8.5-8.8 EER) SUNLINE 000 DESCRIPTION York Sunline 000 Heat Pumps are convertible single package units. All

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C P A C K A G E D E L E C T R I C / E L E C T R I C 2SA13 60HZ E N G I N E E R I N G D A T A Bulletin No. 210454 August 06 Supersedes July 06 MODEL NUMBER IDENTIFICATION SEER 13.00 2 to 2.5 Tons Capacity

More information

MIN/MAX PERFORMANCE IN INCHES WG

MIN/MAX PERFORMANCE IN INCHES WG Fans Roof Exhaust Direct Drive - G Model G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Hz. to Ton (,3 to 7, Btuh) Right Side Control Panel Refrigerant The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed Tag: Project: Engineer: Contractor: Location: ate: pplication: rchitect: Submitted by: The NC model F fire damper utilizes a curtain style blade to prevent the spread of fire through a penetration in a

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

Direct-Fired Heating, Ventilation and Pressurization Systems

Direct-Fired Heating, Ventilation and Pressurization Systems 2000-Series irect-ired Heating, Ventilation and Pressurization Systems imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% OUTSI IR ONLY 2000-Series Selection uide NOT: ll information

More information

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS LINE OVERVIEW S&P s Direct Drive Sidewall Propeller Fan line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

GCS GCS

GCS GCS ENGINEERING T PKGE GS / ELETRI GS16 024 030 036 048 060 GS20 036 048 060 2 to 5 Ton (7.0 to 17.3 ) FUE 80% SEER up to 12.70 Net apacity 23,200 to 59,000 tuh (6.8 to 17.3 ) Input Heating apacity 50,000

More information

Landmark Rooftop Packaged Units

Landmark Rooftop Packaged Units Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

MODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING

MODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING DIRECT DRIVE SIDEWLL PROPELLER FNS WLL HOUSING MOUNTING OPTIONS WLL HOUSING: This heavy-gauge, all galvanized G-90 steel (aluminum optional) housing provides a simple solution to installing a fan and all

More information

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS CEW SERIES CEILING EXPOSED HORIZONTL FN COIL UNITS MGIC IRE BMW SERIES FN COILS RE ETLC LISTED IN CCORDNCE WITH UL 1995 ND RE SSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPNY, L.P. 501

More information

Fan-Powered Low-Height Series

Fan-Powered Low-Height Series Table of Contents Service Model Number Description LHS 2 3 General Data Valve/Controller Guidelines LHS 4 Performance Data Pressure Requirements LHS 5 7 Performance Data Fan Curves LHS 8 9 Performance

More information

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS LINE OVERVIEW Jenco s Direct Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

3900 Dr. Greaves Rd. Kansas City, MO (816) FAX (816)

3900 Dr. Greaves Rd. Kansas City, MO (816) FAX (816) 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 M-series energy recovery ventilator INDOOR side by side discharge STANDARD CONSTRUCTION cabinet 20 (1.0) gage galvanized steel.

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ) THE WLL-MOUNT IR CONDITIONERS - W (HZ) W-SERIES Refrigerant 22 Hz. to Ton (, to 7, Btuh) Right Side Control Panel The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is

More information

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh) Product Data WEATHERMASTER 36S Water Control Induction Air Terminals 19.4 to 131.9 cfm (1770 to 8900 Btuh) Induction air terminals offer: Heating and cooling operation 2-pipe or 4-pipe system options Automatic

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC MODEL FF FEATURES Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation Speed

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

Inline & Sidewall Exhaust Fans

Inline & Sidewall Exhaust Fans F, F 28 Inline & Sidewall xhaust Fans est vailable 3 ays F UL/cUL 705 Power Ventilators 40001 - F with TF motors 40001 - F with TF motors F F is M Licensed for ir Performance F is M Licensed for Sound

More information

The newest addition to RenewAire s broad line of Energy Recovery Ventilators.

The newest addition to RenewAire s broad line of Energy Recovery Ventilators. INTRODUCING HE 1.5X The newest addition to RenewAire s broad line of Energy Recovery Ventilators. The perfect size for the largest number of ventilation applications in the industry: 375-1,400 CFM Advanced

More information

Product Data. Features/Benefits. 39NX Central Station Air-Handling Units. Nominal 2,000 to 55,000 Cfm

Product Data. Features/Benefits. 39NX Central Station Air-Handling Units. Nominal 2,000 to 55,000 Cfm Product Data 39NX Central Station Air-Handling Units Nominal 2,000 to 55,000 Cfm Features/Benefits Sloped, double-wall coil condensate drain pan complies with ASHRAE Standard 62 Double-wall casings solid,

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

Roof & Sidewall Mounted

Roof & Sidewall Mounted G, G Roof & Sidewall Mounted 4 E40001 - G and G UL/cUL Power Ventilators for Smoke ontrol Systems MH11711 - G UL/cUL Listed 705 is standard on In Stock models G and G are M Licensed for Sound and ir Performance

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

CBH17-95V Horizontal Unit CB V

CBH17-95V Horizontal Unit CB V E N G I N E E R I N G D T I R H N D L E R S CB17/CBH17 UP FLOW/HORIZONTL 60 HZ Bulletin No. 210070 July 2008 Supersedes May 2002 CBH17-95V Horizontal Unit CB17-95V Up-Flow Unit Nominal Capacity 7.5 to

More information

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE RAS Product Specifications ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, 14 20 TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency electric

More information

FH Fan-Coil Units Low-Profile, Horizontal

FH Fan-Coil Units Low-Profile, Horizontal FH Fan-oil Units Low-Profile, Horizontal FH Fan-oil Units: Innovative design simplifies installation and service Owners HRI Standard 440-certifi cation ensures exacting performance. The FH fan-coil unit

More information

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9 ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 9 (RTU1) CESMPU025REVAV9 Date: December 1, 2014 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV9 Unit features include: 25 ton MultiPath

More information

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS TECHNICAL GUIDE SUNLINE 2000 TM SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS MODELS B2CH 180 & B1CH 240 15 & 20 NOMINAL TONS 9.9-8.8 EER DESCRIPTION York Sunline 2000 Heat Pumps are convertible single package

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE FAS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

Air Conditioners. Technical Data UATYQ-CY1

Air Conditioners. Technical Data UATYQ-CY1 Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Single Unit Rooftop UATYQ-CY TABLE OF CONTENTS UATYQ-CY

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design

More information