Fan-Powered Low-Height Series

Size: px
Start display at page:

Download "Fan-Powered Low-Height Series"

Transcription

1 Table of Contents Model Number Description PS 2 Service Model Number Description PS 3 General Data Valve/Controller irflow Guidelines PS 4 Performance Data Pressure Requirements PS 5 Performance Data Fan Curves PS 6 7 Performance Data ot ater Coil PS 8 9 Performance Data Electrical Data PS 10 Performance Data coustics PS Dimensional Data PS Mechanical Specifications PS VV-PRC008-EN S 1

2 Fan- Powered Terminal Units The features of the low-height series fan-powered terminal units are described by the product categories shown below in bold. ithin each category the options available are listed. S 2 SCF SF SEF Fan-Powered MOD Unit Model SCF, cooling-only SF, w/ hot water heat SEF, w/ electric heat DSEQ Design Sequence * Design sequence INT Primary Inlet 06 6" inlet size 08 8" inlet size 14RT 14" rectangular inlet size FN Fan Size maximum cfm maximum cfm maximum cfm INS Unit Insulation MT.5 ½" matte-faced MT1 1" matte-faced FF.5 ½" foil-faced FF1 1" foil-faced D1 Dual-wall w/ 1" matte-faced FRF 3/8" closed-cell OUT Outlet Connection F Flanged connection SD Slip and drive connection MTVT Motor Voltage volt fan motor volt fan motor volt fan motor volt fan motor CONTROS Trane-Supplied Controls DD00 Trane actuator only DD01 DDC w/o remote heat DD02 N.C. on/off hot water valve control DD03 Proportional hot water valve control DD04 On/off electric heat control DD05 Pulse-width modulation DD07 N.O. on/off hot water valve control EI71 basic cooling w/ remote heat DPS operates fan PN00 Pneumatic actuator only PN51 ctuator w/ 3011 PVR, w/ DPS PN52 ctuator w/ 3011 PVR, w/ DPM CONTRO1 Customer-Supplied Controls/No Controls PNON Shaft only pneumatic controls by others ENON Shaft only electric controls by others VM2 FM Johnson VM-1420 PR1 FM Seimens w/ GDE 131.1P actuator PR4 FM Seimens w/ Trane actuator PR5 FM Seimens w/ GDE131.1U actuator T01 FM utomated ogic U341V+ T02 FM00 FM utomated ogic U141V+ Factory installation of other s actuator & controller Model Number Description FM01 Factory installation of Trane s actuator and other s controller CONN Controls & eat Connection Side EFT eft side TEN ttenuator IT ttenuator C ot ater Coil 1RO 1-row hot water coil 2RO 2-row hot water coil FUSE Power Fuse IT Power fuse VOT Electric eater Voltage volt, 1-phase volt, 3-phase volt, 1-phase volt, 1-phase volt, 1-phase volt, 1-phase volt, 3-phase volt, 3-phase volt, 3-phase STGE Electric eater Stage 1 1 stage of heat 2 2 stages of heat equal TK Electric eater Kilowatts k k k k k k k k k k k k k k k k k k k k k k k k k k CNTR Electric eater Control MGN 24-volt magnetic contactors MERC 24-volt mercury contactors PEM P.E. w/ magnetic contactors PEME P.E. w/ mercury contactors DIS Power Disconnect Switch IT Power disconnect switch FS Electric eater irflow Switch IT Electric heater airflow switch VV-PRC008-EN

3 Service Model Number Description Digit 1, 2 Unit Type S VariTrane low-height series fan-powered Digit 3 Reheat C Cooling Only E Electric eat ot ater eat Digit 4 Development Sequence F Sixth Digit 5, 6 Primary ir Valve 06 6" inlet (500 cfm) 08 8" inlet (900 cfm) RT (8" x 14" inlet (1800 cfm) Digit 7, 8 Secondary ir Valve 00 N/ Digit 9 Fan 08 Fan 850 maximum cfm J 09 Fan 1200 maximum cfm K 10 Fan 1900 maximum cfm Digit 10, 11 Design Sequence E0 Fifth (factory assigned) Digit 12, 13, 14, 15 Controls ENON No controls, field-installed DDC/electric PNON No controls, field-installed pneumatic DD00 Trane elec actuator only DD01 DDC cooling only DD02 DDC N.C. on/off water valve DD03 DDC prop hot water valve DD04 DDC on/off electric heat control DD05 DDC pulse-width modulation DD07 DDC N.O. on/off water valve FM00 FM customer actuator & control FM01 FM Trane actuator w/ customer VM2 actuator & control FM Johnson controls VM-1420 PR1 FM Seimens w/ GDE131.1P actuator PR4 FM Seimens Trane actuator PR5 FM Seimens w/ GDE131.1U actuator T01 T02 EI71 PN00 PN51 PN52 FM utomated ogic U341V+ FM utomated ogic U141V+ nalog fan-powered on/off reheat PN N.O. Trane pneumatic actuator, R.. stat PN N.O. PVR, duct pressure switch, R.. stat PN N.O. PVR, dual pressure switch, R.. stat Notes: N.C. = Normally-closed N.O. = Normally-opened D Stat = Direct-acting pneumatic t-stat (by others) R Stat = Reverse-acting pneumatic t-stat (by others) PN = Pneumatic FM = Factory installation of customersupplied controller Digit 16 Insulation 1/2" Matte-faced 1" Matte-faced C 1/2" Foil-faced D 1" Foil-faced F 1" Double-wall G 3/8" Closed-cell Digit 17 Motor Type D PSC Motor Digit 18 Motor Voltage 1 115/60/ /60/ /60/ /50/1 Digit 19 Outlet Connection 1 Flanged 2 Slip & Drive Digit 20 Not Used 0 N/ Digit 21 ater Coil 0 None 1 1-Row 2 2-Row Digit 22 Electrical Connections eft (airflow hitting you in the face) Digit 23 Transformer 0 N/ (provided as standard) Digit 24 Power Disconnect 0 None ith Digit 25 Power Fuse 0 None ith Digit 26 Electric eat Voltage 0 None 208/60/1 208/60/3 C 240/60/1 D 277/60/1 E 480/60/1 F 480/60/3 G 347/60/1 575/60/3 J 380/50/3 Digit 27, 28, 29 Electric eat Voltage 000 None k k k k k k k k k k k k k k k k k k k k k k k k k k Digit 30 Electric eat Stages 0 None 1 1 Stage 2 2 Stages Equal Digit 31 Contactors 0 None 1 24-Volt magnetic 2 24-Volt mercury 3 PE with magnetic 4 PE with mercury Digit 32 ir Flow Switch 0 None ith VV-PRC008-EN S 3

4 General Data Valve/Controller irflow Guidelines Primary irflow Control Factory Settings I-P Control ir Valve Maximum Valve Maximum Controller Minimum Controller Type Size (in.) Cfm Cfm Cfm Direct Digital Control/ , UCM , x , Pneumatic with , Volume Regulator , x , , nalog Electronic , x , Primary irflow Control Factory Settings SI Control ir Valve Maximum Valve Maximum Controller Minimum Controller Type Size (in.) /s /s /s Direct Digital Control/ , UCM , x , Pneumatic with , Volume Regulator , x , , nalog Electronic , x , Note: Maximum airflow must be greater than or equal to minimum airflow. S 4 VV-PRC008-EN

5 ir Pressure Drop in. wg (I-P) Inlet/Fan irflow Cooling Only Size Cfm (in. wg) x x Fan irflow 1-Row Coil Size Cfm (in. wg) Performance Data Pressure Requirements ir Pressure Drop Pa (SI) Inlet/Fan irflow Cooling Only Size /s (Pa) x x Fan irflow 1-Row Coil Size /s (Pa) Fan irflow 2-Row Coil Size CFM (in. wg) Notes: 1. Units with Electric Coils Only per fan size add 0.01" (3Pa) to cooling only values. 2. Coil Only pressure drops are just the heating coil. Fan irflow 2-Row Coil Size /s (Pa) VV-PRC008-EN S 5

6 Performance Data Fan Curves (60 z) Pa In. wg Fan Size 08 Discharge Static Pressure Cfm /s irflow Pa In. wg Fan Size Discharge Static Pressure SCF and SEF maximum Minimum 1 row coil maximum 2 row coil maximum Cfm /s irflow Pa In. wg 0.80 Fan Size Discharge Static Pressure S Cfm /s irflow VV-PRC008-EN

7 Performance Data Fan Curves (50 z) Pa In. wg Fan Size / Discharge Static Pressure Cfm /s irflow Pa 99.7 In. wg 0.40 Fan Size /50 SCF and SEF maximum Minimum 1 row coil maximum 2 row coil maximum Discharge Static Pressure Cfm /s irflow Pa In. wg Fan Size / Discharge Static Pressure Cfm /s irflow VV-PRC008-EN S 7

8 Performance Data ot ater Coil (I-P) Fan Size 08 (I-P) ater Pressure irflow (Cfm) Rows Gpm Drop (ft) Row Capacity M Row Capacity M Fan Size 09 (I-P) ater Pressure irflow (Cfm) Rows Gpm Drop (ft) Row Capacity M Row Capacity M Fan Size 10 (I-P) ater Pressure irflow (Cfm) Rows Gpm Drop (ft) Row Capacity M Row Capacity M Notes: 1. Fouling Factor = The following equations may be used in calculating eaving ir Temperature (T) and ater Temperature Difference (TD). 3. Capacity based on 70 F entering air temperature and 180 F entering water temperature. Refer to correction factors for different entering conditions. T = ET + ( M x Cfm ) TD = ET - T = Temperature Correction Factors for ater Pressure Drop (ft) verage ater Temperature Correction Factor Temperature Correction Factors for Coil Capacity (M) Entering ater Minus Entering ir Correction Factor Coils ater eights Internal Internal Operating Unit Fan Coil Volume Volume eight Type Size Type (in. 3 ) (gal.) (lbs) SF 08 1-Row SF 09,10 1-Row SF 08 2-Row SF 09,10 2-Row ( ) 2 x M Gpm S 8 VV-PRC008-EN

9 Performance Data ot ater Coil (SI) Fan Size 08 (SI) ater Pressure irflow (/s) Rows /s Drop (kpa) Row Capacity k Row Capacity k Fan Size 09 (SI) ater Pressure irflow (/s) Rows /s Drop (kpa) Row Capacity k Row Capacity k Fan Size 10 (SI) ater Pressure irflow (/s) Rows /s Drop (kpa) Row Capacity k Row Capacity k Notes: 1. Fouling Factor = The off-coil temperature of the hot water coil on parallel fan-powered units must not exceed 60 C. 3. The following equations may be used in calculating eaving ir Temperature (T) and ater Temperature Difference (TD). 4. Capacity based on 21 C entering air temperature and 82 C entering water temperature. Refer to correction factors for different entering conditions. T = ET + ( k x 0.83 k /s ) TD = ET - T = ( (4.19)/s) Temperature Correction Factors for ater Pressure Drop (ft) verage ater Temperature Correction Factor Temperature Correction Factors for Coil Capacity (M) Entering ater Minus Entering ir Correction Factor Coils ater eights Internal Internal Operating Unit Fan Coil Volume Volume eight Type Size Type (m 3 ) () (kg) SF 08 1-Row SF 09,10 1-Row SF 08 2-Row SF 09,10 2-Row VV-PRC008-EN S 9

10 Performance Data Electrical Data SEF Electric Coil k Guidelines - Minimum to Maximum Fan Single-Phase Voltage Three-Phase Voltage Size Stages 208V 240V 277V 347V 480V 208V 480V 575V Notes: 1. Coils available with 24 VC magnetic or mercury contactors, load carrying P.E. switches, and P.E. switch with magnetic or mercury contactors. 2. vailable k increments are by 0.5 from 0.5 k to 8.0 k and by 1.0 k from 9.0 to 18.0 k. 3. Each stage will be equal in k output. 4. ll heaters contain an auto thermal cutout and a manual reset cutout. 5. The current amp draw for the heater elements is calculated by the formula below. 6. Only two stages of electric reheat available with Trane controls. Fan Electrical Performance Maximum Fan Motor mperage (F) Fan Size P 115 VC 277 VC 347 VC 230/50 z 08 1/ x 1/ x 1/8 4.7 ea ea ea ea. Notes: 1. Electric eat Units - Units with Primary Voltage of 208/60/1, 208/60/3 or 240/60/1 use 115 VC fan motors. 2. Electric eat Units - Units with Primary Voltage of 277/60/1, 480/60/1 or 480/60/3 use 277 VC fan motors. 3. Electric eat Units - Units with Primary Voltage of 347/60/1 or 575/60/3 use 347 VC fan motors. 4. Values are for standard, single-speed, permanent split capacitor type motors. Consult factory for non-standard motor performance. Minimum Circuit mpacity (MC) Equation MC = (motor amps + heater amps) x 1.25 Maximum Overcurrent Protection (MOP) Equation MOP = (2.25 x motor amps) + heater amps General Sizing Rules: If MOP = 15, then fuse size = 15 If MOP = 19, then fuse size = 15 with one exception. If heater amps x 1.25 > 15, then fuse size = 20. If MOP MC, then choose next fuse size greater than MC. Control fusing not applicable. Standard Fuse Sizes: 15, 20, 25, 30, 35, 40, 45, 50, and 60. Useful formulas: Cfm x TD k = 3145 k = 1214 x /s x TD k x famps = Primary Voltage x Ö 3 1famps = k x 1000 Primary Voltage TD = k x 3145 Cfm TD = k 1214 x /s S 10 VV-PRC008-EN

11 Performance Data coustics Discharge Sound Power (d) Discharge Sound Power (d) 0.5" Inlet 1.0" Inlet 2.0" Inlet 3.0" Inlet Fan Inlet Pressure (127 Pa) Pressure (254 Pa) Pressure (508 Pa) Pressure (762 Pa) Size Size Cfm /s x x Notes: 1. ll data are measured in accordance with current Industry Standard RI 880, version ll sound power levels, d re: watts. Radiated Sound Power (d) Radiated Sound Power (d) 0.5" Inlet 1.0" Inlet 2.0" Inlet 3.0" Inlet Fan Inlet Pressure (127 Pa) Pressure (254 Pa) Pressure (508 Pa) Pressure (762 Pa) Size Size Cfm /s x x Notes: 1. ll data are measured in accordance with current Industry Standard RI 880, version ll sound power levels, d re: atts. Fan Only Sound Power (d) Discharge Sound Power (d) Radiated Sound Power (d) Fan Outlet Octave ands Octave ands Size Static Cfm /s (63 Pa) (63 Pa) (63 Pa) Notes: 1. ll data are measured in accordance with current Industry Standard RI 880, version ll sound power levels, d re: atts. VV-PRC008-EN S 11

12 Performance Data coustics Sound Noise Criteria (NC) Fan and 100% Primary Discharge Radiated NC evel NC evel Fan Inlet Fan 0.5" 1.0" 2.0" 3.0" Fan 0.5" 1.0" 2.0" 3.0" Size Size Cfm /s Only (127 Pa) (254 Pa) (508 Pa) (762 Pa) Only (127 Pa) (254 Pa) (508 Pa) (762 Pa) x x Notes: 1. represents NC levels below NC NC Values are calculated using current Industry Standard RI 885, 2002 addendum to revision Radiated Transfer Function obtained from ppendix E, Type 2 Mineral Fiber Insulation. RI DISCRGE TRNSFER FUNCTION SSUMPTIONS: Octave and Small ox (< 300 cfm) Medium ox ( cfm) arge ox (> 700 cfm) Note: dd to terminal unit sound power to determine discharge sound pressure in the space. RI RDITED TRNSFER FUNCTION SSUMPTIONS: Octave and Type 1 Glass Fiber Type 2 Mineral Fiber Insulation Type 3 Solid Gypsum oard Note: Select the ceiling type which most closely represents the application. Next, add to terminal unit sound power to determine radiated sound pressure in the space. S 12 VV-PRC008-EN

13 Performance Data coustics Discharge Sound Power (d) Fan Only RI Conditions Fan Inlet 1.5" Inlet Pressure (381 Pa) Size Size Cfm /s , , 8x x Radiated Sound Power (d) Fan Only RI Conditions Fan Inlet 1.5" Inlet Pressure (381 Pa) Size Size Cfm /s , , 8x x Radiated Sound Power (d) Fan and Valve RI Conditions Fan Inlet 1.5" Inlet Pressure (381 Pa) Size Size Cfm /s CFM /s x x Notes: 1. ll data are measured in accordance with current Industry Standard RI 880, version ll sound power levels, d re: atts. VV-PRC008-EN S 13

14 Dimensional Data SERIES O-EIGT COOING (SCF) FN SIZE 8 SIZE INET/FN INET SIZE (NOMIN Ø) 6" (152 mm) 8" (203 mm) CFM/PS FN INET 800 (378) 800 (378) 500 (236) 900 (425) 11.50" (292 mm) 24.00" (610 mm) 40.00" (1016 mm) DISCRGE DIMENSIONS 15.00" (381 mm) 10.00" (254 mm) T S (KGS) 63 (29) 64 (29) 4.00" (102 mm) FO RING TUING IRFO 4.00" (102 mm) FITER SIZES 10" x 20" x 1" (254 mm x 508 mm x 25 mm) IR VVE 6.50" (165 mm) CTUTOR 6.50" (165 mm) CONTRO OX NOG OR DDC/UCM FN CONTRO OX TOP VIE 5.50" (140 mm) IRFO DISCRGE OUTET RECOMMENDED DUCT SIZES 8.25" (210 mm) CUSTOMER NOTES: 1. llow 6" (152 mm) clearance for plenum inlet. 2. Filter mounts in filter frame. 3. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange. CK VIE 4.50" (114 mm) 0.75" (19 mm) 4. Fan and motor access is through plenum inlet. S 14 VV-PRC008-EN

15 Dimensional Data SERIES O-EIGT COOING (SCF) FN SIZES 9 & 10 SIZE INET/FN RT09 14RT10 INET SIZE (NOMIN Ø) 8" (203 mm) 1800 (850) 8" x 14" 1100 (519) (203 mm X 356 mm) 8" x 14" 1800 (850) (203 mm X 356 mm) CFM/PS FN INET 900 (425) 2000 (944) 2000 (944) 11.50" (292 mm) 48.00" (1219 mm) 36.00" (914 mm) DISCRGE DIMENSIONS 34.00" (864 mm) 10.00" (254 mm) T S (KGS) 81 (37) 82 (37) 89 (40) 6.50" (165 mm) 4.00" (102 mm) FO RING TUING IRFO IR VVE 4.00" (102 mm) CTUTOR 6.50" (165 mm) CONTRO OX NOG OR DDC/UCM FITER SIZES (QTY 2) 10" x 20" x 1" (254 mm x 508 mm x 25 mm) FN CONTRO OX TOP VIE IRFO DISCRGE OUTET RECOMMENDED DUCT SIZE. 5.50" (140 mm) CUSTOMER NOTES: 1. llow 6" (152 mm) clearance for plenum inlet. 2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange. 3. Fan and motor access is through plenum inlet. 8.25" (210 mm) CK VIE VV-PRC008-EN S 15

16 Dimensional Data SERIES O-EIGT OT TER (SF) FN SIZE 8 SIZE INET SIZE INET/FN (NOMIN Ø) " (152mm) 8" (203mm) CFM/PS FN INET 800 (378) 800 (378) 500 (236) 900 (425) 11.50" (292 mm) 24.00" (610 mm) DISCRGE DIMENSIONS 40.00" (1016 mm) 15.00" (381 mm) 10.25" (260 mm) T S (KGS) 72 (33) 73 (33) 4.00" (102 mm) FO RING TUING IRFO 4.00" (102 mm) FITER SIZES 10" x 20" x 1" (254 mm x 508 mm x 25 mm) IR VVE 6.50" (165 mm) CTUTOR 6.50" (165 mm) CONTRO OX NOG OR DDC/UCM TOP VIE FN CONTRO OX 76 mm x 178 mm (3.00" x 7.00") COI CCESS COI TER IRFO DISCRGE OUTET 5.50" (140 mm) 4.50" (114 mm) CUSTOMER NOTES: 1. llow 6" (152 mm) clearance for inlet. 2. Filter mounts in filter frame. 8.25" (210 mm) 3. Coil furnished with female sweat connections. 4. Rotate coil 180 for left hand coil connection. 5. Fan and motor access is through plenum inlet. CK VIE 0.75" (19 mm) S 16 VV-PRC008-EN

17 Dimensional Data SERIES O-EIGT OT TER (SF) FN SIZES 9 & 10 SIZE INET/FN INET SIZE (NOMIN Ø) FN " (203 mm) 1800 (850) 14RT09 8" x 14" 1100 (519) (203 mmx356 mm) 14RT10 8" x 14" 1800 (850) (203 mmx356 mm) CFM/PS INET 900 (425) 2000 (944) 2000 (944) 11.50" (292 mm) 48.00" (1219 mm) DISCRGE DIMENSIONS 36.00" (914 mm) 34.00" (864 mm) 10.00" (254 mm) T S (KGS) 96 (44) 97 (44) 104 (49) FO RING TUING 5.50" (140 mm) CTUTOR 4.00" (102 mm) 6.50" (165 mm) IRFO IR VVE 4.00" (102 mm) 6.50" (165 mm) CONTRO OX NOG OR DDC/UCM FN CONTRO OX FITER SIZES (QTY 2) 10" x 20" x 1" (254 mm x 508 mm x 25 mm) (76 mm x 178 mm) 3.00" x 7.00" COI CCESS 6.75 (171 mm) TOP VIE IRFO DISCRGE OUTET CUSTOMER NOTES: 1. llow 6" (152 mm) clearance for plenum inlet. 2. Filter mounts in filter frame. 3. Coil furnished with stub sweat connections. 4. Rotate coil 180 for right-hand coil connection. 5. Fan and motor access is through plenum inlet. 8.25" (210 mm) 6. Coils are provided without internal insulation. If the unit is to be installed in a location with high humidity, external insulation around the heating coil should be installed as required. CK VIE VV-PRC008-EN S 17

18 Dimensional Data COI INFORMTION FOR O-EIGT SERIES 1-RO COI SIZE INET/FN COI CONNECTION " (22 mm) O.D. 7.75" (197 mm) 1.50" (38 mm) 15.00" (381 mm) 10.12" (257 mm) RT09 14RT " (864 mm) 6.75" (171 mm) INET 7.75" (198 mm) O IRFO CCESS PNE INET CUSTOMER NOTES: 1. ocation of coil connections is determined by facing air stream... Coil connections shown, R.. opposite. 2. Coil furnished with stub sweat connections. 3. Use inlet () when rotating the coil Coil height and width is dependent upon unit height and width. 3.40" (86 mm) 1.12" (29 mm) 5. ccess Panel is standard. 1.12" (29 mm) S 18 VV-PRC008-EN

19 Fan-Powered Dimensional Data COI INFORMTION FOR O-EIGT SERIES 2-RO COI SIZE INET/FN COI CONNECTION RT09 14RT10.875" (22 mm) O.D. 6.25" (159 mm) 2.00" (51 mm) 15.00" (381 mm) 10.12" (254 mm) 34.00" (864 mm) 6.75" (171 mm) INET 7.81" (198 mm) IRFO CCESS PNE INET IRFO CUSTOMER NOTES: 3.40" (86 mm) 1.12" (29 mm) 1. ocation of coil connections is determined by facing air stream... Coil connections shown, R.. opposite. 1.94" (51 mm) 2. Coil furnished with stub sweat connections. 3. Use inlet () when rotating the coil Coil height and width is dependent upon unit height and width. ccess Panel is standard. VV-PRC008-EN S 19

20 Dimensional Data SERIES O-EIGT EECTRIC (SEF) FN SIZE 8 SIZE INET SIZE INET/FN (NOMIN Ø) " (152 mm) " (203 mm) CFM/PS FN INET 800 (378) 800 (378) 500 (236) 900 (425) 11.50" (292 mm) 24.00" (610 mm) DISCRGE DIMENSIONS 40.00" (1016 mm) 15.90" (404 mm) 10.30" (262 mm) T S (KGS) 81 (37) 82 (37) 5.50" (140 mm) 6.50" (165 mm) 4.00" (102 mm) FO RING TUING IRFO IR VVE 4.00" (102 mm) FITER SIZES 10" x 20" x 1" (254 mm x 508 mm x 25 mm) CTUTOR 6.50" (165 mm) CONTRO OX NOG OR DDC/UCM 22.00" (559 mm) FN CONTRO OX TERMIN OX PENUM RE 12" (305 mm) EECTRIC ETER TOP VIE 8.00" (203 mm) IRFO DISCRGE OUTET CUSTOMER NOTES: 1. llow 6" (152 mm) clearance for plenum inlet. 2. Inside duct dimensions equal outlet size (x). llow 48" (1219 mm) of straight duct downstream of unit before first runout. 3. Terminal box access door is side hinged. llow for clearance. (22" (559 mm) long x 11.50" (292 mm) high). 4. Filter mounts in filter frame. 5. Knockouts for power supply provided in top and bottom of terminal box. 6. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange. 7. Fan and motor access is through plenum inlet. CK VIE 8. Coils are provided without internal insulation. If the unit is to be installed in a location with high humidity, external insulation around the heating coil should be installed as required. S 20 VV-PRC008-EN

21 Dimensional Data SERIES O-EIGT EECTRIC (SEF) FN SIZES 9 & 10 SIZE INET/FN RT09 14RT10 INET SIZE (NOMIN Ø) FN 8" (203 mm) 1800 (850) 8" x 14" 1100 (519) (203 mmx356 mm) 8" x 14" 1800 (850) (203 mmx356 mm) CFM/PS INET 900 (425) 2000 (944) 2000 (944) 11.50" (292 mm) 48.00" (1219 mm) 36.00" (914 mm) DISCRGE DIMENSIONS 36.00" (914 mm) 10.00" (254 mm) T S (KGS) 113 (51) 114 (52) 120 (54) 6.50" (165 mm) 4.00" (102 mm) FO RING TUING IRFO IR VVE 4.00" (120 mm) CTUTOR 6.50" (165 mm) CONTRO OX NOG OR DDC/UCM FITER SIZES (Qty 2) 10" x 20" x 1" (254 mm x 508 mm x 25 mm) 5.50" (140 mm) FN CONTRO OX TOP VIE 22.00" (559 mm) 8.00" (203 mm) PENUM RE EECTRIC ETER IRFO DISCRGE OUTET CUSTOMER NOTES: 1. llow 6" (152 mm) clearance for plenum inlet. 2. Inside duct dimensions equal outlet size (x). llow 48" (1219 mm) of straight duct downstream of unit before first runout. 3. Terminal box access door is side hinged. llow for clearance. (22" (559 mm) long x 11.50" (292 mm) high). 4. Filter mounts in filter frame. 5. Knockouts for power supply provided in top and bottom of terminal box. 6. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange. 7. Fan and motor access is through plenum inlet. 8.25" (210 mm) CK VIE 8. Coils are provided without internal insulation. If the unit is to be installed in a location with high humidity, external insulation around the heating coil should be installed as required. VV-PRC008-EN S 21

22 Mechanical Specifications MODES SCF, SF, and SEF ow-height series fan-powered terminal units. SCF Cooling Only SF ith ot ater Coil SEF ith Electric Coil CSING 22-gage galvanized steel. anger brackets, plenum access, and filter which is on the plenum inlet are provided as standard. GENCY ISTING The unit is U and Canadian U isted as a room air terminal unit. Control # 9N65. RI 880 Certified. INSUTION 1/2" (12.7 mm) Matte-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with ½-inch, 1.75 lb/ft 3 (12.7 mm, kg/m 3 ) composite density glass fiber with a high-density facing of 4.0 lb/ft 3 (64 kg/m 3 ). The insulation R-Value is 1.9. The insulation is U listed and meets NFP-90 and U 181 standards. There are no exposed edges of insulation (complete metal encapsulation). 1" (25.4 mm) Matte-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1-inch, 1.55 lb/ft 3 (25.4 mm, 24.8 kg/m 3 ) composite density glass fiber with a high-density facing of 4.0 lb/ft 3 (64 kg/m 3 ). The insulation R-Value is The insulation is U listed and meets NFP- 90 and U 181 standards. There are no exposed edges of insulation (complete metal encapsulation). 1/2" (12.7 mm) Foil-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with ½-inch, 2.0 lb/ft 3 (12.7 mm, kg/m 3 ) density glass fiber with foil facing. The insulation R-Value is 2.2. The insulation is U listed and meets NFP-90 and U 181 standards as well as bacteriological standard STM C 665. There are no exposed edges of insulation (complete metal encapsulation). 1" (25.4 mm) Foil-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1-inch, 2.0 lb/ft 3 (25.4 mm, kg/m 3 ) density glass S 22 fiber with foil facing. The insulation R-Value is 4.3. The insulation is U listed and meets NFP-90 and U 181 standards as well as bacteriological standard STM C 665. There are no exposed edges of insulation (complete metal encapsulation). 1" (25.4 mm) Double-wall Insulation The interior surface of the unit casing is acoustically and thermally lined with a 1-inch, 2.1 lb./ft 3 (25.4 mm, 33.6 kg/m 3 ) composite density glass fiber with high-density facing. The insulation R-value is 3.0. The insulation is U listed and meets NFP- 90 and U 181 standards. The insulation is covered by an interior liner made of 26-gage galvanized steel. ll wire penetrations are covered by grommets. There are no exposed edges of insulation (complete metal encapsulation). 3/8" (9.5 mm) Closed-cell Insulation The interior surface of the unit casing is acoustically and thermally lined with 3/8-inch, 4.4 lb/ft 3 (9.5 mm, 40.0 kg/m 3 ) closed-cell insulation. The insulation is U listed and meets NFP-90 and U 181 standards. The insulation has an R-value of 1.4. There are no exposed edges of insulation (complete metal encapsulation). PRIMRY IR VVE ir Valve Round The primary air inlet connection is an 18-gage galvanized steel cylinder sized to fit standard round duct. multiple-point, averaging flow sensing ring is provided with balancing taps for measuring +/-5% of unit cataloged airflow. n airflow-versus-pressure differential calibration chart is provided. The damper blade is constructed of a closed-cell foam seal that is mechanically locked between two 22-gage galvanized steel disks. The damper blade assembly is connected to a cast zinc shaft supported by selflubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over-stroking. t 4.0 in. wg, air valve leakage does not exceed 1% of cataloged airflow. ir Valve Rectangular Inlet collar is constructed of 22-gage galvanized steel sized to fit standard rectangular duct. n integral multiple-point, averaging flow-sensing ring provides primary airflow measurement within +/-5% of unit cataloged airflow. Typical inlet conditions: flex duct and 90 inlets to the damper. Damper is 22-gage galvanized steel with polyolefin foam seal. The damper blade assembly is connected to a cast zinc shaft supported by self-lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over-stroking. t 3.0 in. wg, air valve leakage does not exceed 44 cfm (21 /s). ir Valve Sizes vailable (I-P) ir Valve Fan Size irflow irflow (in.) (Cfm) Size (Cfm) x x ir Valve Sizes vailable (Pa) ir Valve Fan Size irflow Flow (mm) (/s) Size (/s) 06 (152) (203) (203) x14 (203x356) x14 (203x356) FN MOTOR Single-speed, direct-drive, permanent split capacitor type. Thermal overload protection provided. Motors will be designed specifically for use with an open SCR. Motors will be single-speed with standard SCR for speed control. Motors will accommodate antibackward rotation at start up. Motor and fan assembly is isolated from terminal unit. FN SPEED CONTRO Variable Speed Control Switch (SCR) The SCR speed control device is provided as standard and allows the operator infinite fan speed adjustment so the fan output may be modified to achieve exact cfm requirements. TRNSFORMER The 50 V transformer is factoryinstalled in the fan control box to provide 24 VC for controls. POER DISCONNECT The power disconnect is provided as standard and allows the operator to turn the unit on or off by toggling to the appropriate setting. This switch breaks both legs of power to the fan and the electronic controls (if applicable). Not provided on SEF with pneumatic controls VV-PRC008-EN

23 Mechanical Specifications OUTET CONNECTION Flanged Connection rectangular opening on the unit discharge to accept a 90 flanged ductwork connection. FITER 1" (25 mm) filter is provided on the plenum inlet and attaches to the unit with a filter frame. OT TER COI ater Coils factory-installed on the plenum inlet. The coil has 1-row with 144 aluminumplated fins per foot (.305 m) and, if needed, 2-row with 144 aluminumplated fins per foot (.305 m). Full fin collars provided for accurate fin spacing and maximum fin-tube contact. The 3/8" (9.5 mm) OD seamless copper tubes are mechanically expanded into the fin collars. Coils are proof tested at 450 psig (3102 kpa) and leak tested at 300 psig (2068 kpa) air pressure under water. Coil connections are brazed with left-hand configuration. EECTRIC ET COI The electric heater is a factory-provided and -installed, U recognized resistance open-type heater. It also contains a disc-type automatic pilot duty thermal primary cutout, and manual reset load carrying thermal secondary device. eater element material is nickel-chromium. The heater terminal box is provided with 7/8" (22 mm) knockouts for customer power supply. Terminal connections are plated steel with ceramic insulators. eater control access is on the discharge side of the unit. ll fanpowered units with electric reheat are single-point power connections. EECTRIC ET OPTIONS Magnetic Contactor n optional electric heater 24-volt contactor for use with direct digital control (DDC) or analog-electronic controls. Mercury Contactor n optional electric heater 24-volt contactor for use with direct digital control (DDC) or analog-electronic controls. P.E. Switch with Magnetic Contactor This optional switch and magnetic contactor is for use with pneumatic controls. irflow Switch n optional air pressure device designed to disable the heater when the system fan is off. Power Fuse If power fuse is chosen with a unit with electric heat, then a safety fuse located in the line of power of the electric heater to prevent power surge damage to the electric heater. ny electric heat unit with a calculated MC greater than or equal to 30 will have a fuse provided Disconnect Switch n optional factory-provided door interlocking disconnect switch on the heater control panel disengages primary voltage to the terminal. UNIT CONTROS SEQUENCE OF OPERTION The controller will start and run the fan continuously during the occupied mode and intermittently during the unoccupied mode. Upon a further call for heat, any hot water or electric heat associated with the unit is enabled. DIRECT DIGIT CONTROS DDC ctuator Trane 3-wire, 24-VC, floating-point control actuator with linkage release button. Torque is 35 in-lb minimum and is non-spring return with a 90-second drive time. Travel is terminated by end stops at fully-opened and -closed positions. n integral magnetic clutch eliminates motor stall. Direct Digital Controller The microprocessor based terminal unit controller provides accurate, pressureindependent control through the use of a proportional integral control algorithm and direct digital control technology. The controller, named the Unit Control Module (UCM), monitors zone temperature setpoints, zone temperature and its rate of change, and valve airflow using a differential pressure signal from the pressure transducer. dditionally, the controller can monitor either supply duct air temperature or CO 2 concentration via appropriate sensors. The controller is provided in an enclosure with 7/8" (22 mm) knockouts for remote control wiring. Trane UCM zone sensor is required. DDC Zone Sensor The UCM controller senses zone temperature through a sensing element located in the zone sensor. In addition to the sensing element, zone sensor options may include an externally-adjustable setpoint, communications jack for use override button to change the individual controller from unoccupied to occupied mode. The override button has a cancel feature that will return the system to unoccupied. ired zone sensors utilize a thermistor to vary the voltage output in response to changes in the zone temperature. iring to the UCM controller must be 18- to 22-awg. twisted pair wiring. The setpoint adjustment range is 50 88ºF (10 31 C). Depending upon the features available in the model of sensor selected, the zone sensor may require from a 2-wire to a 5-wire connection. ireless zone sensors report the same zone information as wired zone sensors, but do so using radio transmitter technology. Therefore with wireless, wiring from the zone sensor to the UCM is unnecessary. Digital Display Zone Sensor with iquid Crystal Display (CD) The digital display zone sensor contains a sensing element, which sends a signal to the UCM. iquid Crystal Display (CD) displays setpoint or space temperature. Sensor buttons allow the user to adjust setpoints, and allow space temperature readings to be turned on or off. The digital display zone sensor also includes a communication jack for use with a portable edit device, and an override button to change the UCM from unoccupied to occupied. The override button has a cancel feature, which returns the system to unoccupied mode. System Communications The Controller is designed to send and receive data from a Tracer Summit or other Trane controllers. Current unit status conditions and setpoints may be monitored and/or edited via this data communication feature. The network type is a twisted wire pair shielded serial communication. NOG EECTRONIC CONTROS nalog ctuator Trane 3-wire, 24-VC, floating-point control actuator with linkage release button. Torque is 35 in-lb minimum and is non-spring return with a 90-second drive time. Travel is terminated by end stops at fully-opened and -closed positions. n integral magnetic clutch eliminates motor stall. nalog Electronic Controller P.E. Switch with Mercury The controller consists of a circuit board Contactor This optional switch and that offers basic VV unit operation and mercury contactor is for use with additional override functions and pneumatic controls. operates using 24 VC power. The with a portable edit device, and an controller uses a capacitive type VV-PRC008-EN S 23

24 Mechanical Specifications pressure transducer to maintain consistent air delivery regardless of system pressure changes. The enclosure with 7/8" (22 mm) knockouts for remote control wiring. Trane electronic zone sensor is required. nalog Electronic Thermostat This single-temperature, wall-mounted electronic device utilizes a thermistor to vary the voltage output in response to changes in the zone temperature. Connections to the VV unit circuit board are made using standard threeconductor thermostat wire. The setpoint adjustment range is 63 85ºF (17 29 C). The sensor is available in two models. One model has a concealed, internally-adjustable setpoint. The other model has an externally-adjustable setpoint. PNEUMTIC CONTROS Normally Open ctuator Pneumatic 3 to 8 psig (20 to 55 kpa) spring-range pneumatic actuator Pneumatic Volume Regulator (PVR) The regulator is a thermostat reset velocity controller, which provides consistent air delivery within 5% of cataloged flow down to 18% of unit cataloged cfm, independent of changes in system static pressure. Factory-calibrated, field-adjustable setpoints for minimum and maximum flows. verage total unit bleed rate, excluding thermostat, is 28.8 scim at 20 psig (7.87 ml/min at 138 kpa) supply. UNIT OPTIONS Power Fuse (SCF, SF) Optional fuse is factory-installed in the primary voltage hot leg. OT TER VVES Two-Position Valve The valve is a field-adaptable, 2-way or 3-way configuration and ships with a cap to be field-installed when configured as a 2-way valve. ll connections are National Pipe Thread (NPT). The valve body is forged brass with a stainless steel stem and spring. Upon demand, the motor strokes the valve. hen the actuator drive stops, a spring returns the valve to its fail-safe position. Flow Capacity 1.17 Cv Overall Diameter ½" NPT Close-off Pressure 30 psi (207 kpa) Flow Capacity 3.0 Cv Overall Diameter 3/4" NPT Close-off Pressure 14.5 psi (100 kpa) Flow Capacity 6.4 Cv Overall Diameter 1" NPT Close-off Pressure 9 psi (62 kpa) Maximum Operating Fluid Temperature 203ºF (95ºC) Maximum system pressure 300 psi (2067 kpa). Maximum static pressure 300 psi (2067 kpa) Electrical Rating 7 V at 24 VC, 6.5 atts, 50/60 z 8 feet (2.44 m) of plenum rated wire lead is provided with each valve. Proportional ater Valve The valve is a field-adaptable, 2-way or 3- way configuration and ships with a cap over the bottom port. This configures the valve for 2-way operation. For 3-way operation, remove the cap. The valve is designed with an equal percentage plug. The intended fluid is water or water and glycol (50% maximum glycol). The actuator is a synchronous motor drive. The valve is driven to a predetermined position by the UCM controller using a proportional plus integral control algorithm. If power is removed, the valve stays in its last position. The actuator is rated for plenum applications under U 94-5V and U 873 standards. Pressure and Temperature Ratings The valve is designed and tested in full compliance with NSI Class 250 pressure/temperature ratings, NSI Class IV control shutoff leakage, and IS S75.11 flow characteristic standards. Flow Capacity 7.30 Cv, 4.60 Cv, 1.80 Cv, and 0.79 Cv Overall Diameter ½" NPT, ¾" NPT (7.30 Cv) Maximum llowable Pressure 345 psi (2415 kpa) Maximum Operating Fluid Temperature 281ºF (138 C) Maximum Close-off Pressure 55 psi Electrical Rating 4 V at 24 VC. 10 feet (3.05 m) of plenum rated 22-gage wire for connection. Terminations are #6 stabs. S 24 VV-PRC008-EN

Fan-Powered Low-Height Series

Fan-Powered Low-Height Series Table of Contents Service Model Number Description LHS 2 3 General Data Valve/Controller Guidelines LHS 4 Performance Data Pressure Requirements LHS 5 7 Performance Data Fan Curves LHS 8 9 Performance

More information

Single-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6

Single-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6 Table of Contents Model Number Description SD 2 3 Service Model Number Description SD 4 Selection Procedure SD 5 6 General Data Valve/Controller Airflow Guidelines SD 7 Performance Data Pressure Requirements

More information

Fan-Powered Series. Table of Contents. Model Number Description FPS 2 3. Service Model Number Description FPS 4. Selection Procedure FPS 5 7

Fan-Powered Series. Table of Contents. Model Number Description FPS 2 3. Service Model Number Description FPS 4. Selection Procedure FPS 5 7 Table of Contents Model Number Description FPS 2 3 Service Model Number Description FPS 4 Selection Procedure FPS 5 7 General Data Valve/Controller Airflow Guidelines FPS 8 Performance Data Pressure Requirements

More information

Fan-Powered Parallel

Fan-Powered Parallel Table of Contents Service Model Number Description FPP 2 Selection Procedure FPP 3 5 General Data Valve/Controller Guidelines FPP 6 Performance Data ir Pressure Requirements FPP 7 8 Performance Data Fan

More information

Fan-Powered Parallel

Fan-Powered Parallel Table of Contents Model Number Description 76 Selection Procedure 77-79 General Data Setting Guidelines 80 Performance Data Pressure Requirements 81 Performance Data Fan Curves 82-85 Performance Data Hot

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals catalog SDL Single-Duct, Low-Height, VAV Terminals Catalog: ET130.13-EG2 (708) TABLE OF CONTENTS Single-Duct, Low-Height VAV Terminals Features and Benefits....................... 2 Controls..................................

More information

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals catalog SDL Single-Duct, Low-Height, VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 3 Construction Features... 4 Standard and Optional Features.... 5 Dimensional and Weight Data....

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

HOW TO SPECIFY SDV UNITS

HOW TO SPECIFY SDV UNITS HOW TO SPECIFY SDV UNITS MODEL UNIT CONFIG LINER CASING OPTIONS CONST. SIDE INLET SIZE DISCHARGE OPTIONS CONTROL TYPE UNIT ACCESSORIES HEAT kw ELECTRIC HEAT ACCESSORIES SCR HEAT ACCESSORIES SDV 0 - Standard

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

SDL Single-Duct, Low-Height, VAV Terminals

SDL Single-Duct, Low-Height, VAV Terminals SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS D2 RETROFIT/YPASS TERMINA UNITS Table of Contents RETROFIT/YPASS TERMINA UNITS RVE This retrofit terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable

More information

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm Product Data 35E Single Duct Terminal Units for Variable Air Volume Systems Nominal 45 to 7100 cfm Single duct variable air volume (VAV) terminal units provide: 22-gage galvanized steel, unit casing lined

More information

Installation, Operation, and Maintenance

Installation, Operation, and Maintenance Installation, Operation, and Maintenance VariTrane Single-Duct and Fan-Powered Units All VariTrane VAV models with pneumatic, electronic, DDC controls, and diffusers. VCCF04-24 VCEF04-24 VCF04-24 SAFETY

More information

SINGLE DUCT TERMINAL UNITS 3000 SERIES

SINGLE DUCT TERMINAL UNITS 3000 SERIES 000 SERIES 000 SERIES VRIBLE OR CONSTNT VOLUME PRODUCT OVERVIE Nailor 000 Series Single Duct Terminal units are simply put, versatile. hether the requirement calls for a constant or variable air volume

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 23 3600 - AIR TERMINAL DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fan-powered air terminal units/devices. 2. Shut off air terminal units/devices. 3. Dual duct terminal units/devices.

More information

Submittal. Front View Side View

Submittal. Front View Side View RBHO Horizontal Low Profile Concealed Free Return Submittal FCU-RBHO-1.0 07-25-18 Top View (Drain Pan Omitted) Bottom View Front View Side View Left hand unit shown. All dimensions are inches [millimeters].

More information

IAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW

IAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW SINGLE DUCT w/hot WATER HEAT Model AVW Model AVW The Carnes Model AVW is available as a basic control unit with hot water reheat and open end discharge, with an optional sound attenuator module, and optional

More information

TSS Single-Duct VAV Terminals

TSS Single-Duct VAV Terminals TSS Single-Duct VAV Terminals Model TSS construction features Standard Construction Mechanical-lock construction ensures lowest possible casing leakage Roll-formed inlet collar with integral stiffening

More information

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES 30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an

More information

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778] FCU-THBP-1.0 08-22-18 THBP Horizontal Low Profile Plenum Return Top View (Drain Pan Omitted) Bottom View Front View Left hand unit shown. All dimensions are inches [millimeters]. Side View Unit Size A

More information

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101) 500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5

More information

Variable Air Volume (VAV) Pressure Independent Control

Variable Air Volume (VAV) Pressure Independent Control VAV Terminal Units Asli Variable Air Volume (Vav) Terminal Units are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of conditioned

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

IAQ. Model AVC. SINGLE DUCT VAV Model AVC NON FAN POWERED UNITS SINGLE DUCT VAV Model AVC Model AVC The Carnes Model AVC is available as a basic control unit with open end discharge, with an optional multi-discharge adapter module, or sound attenuator

More information

LMHS BASIC UNIT NO CONTROLS

LMHS BASIC UNIT NO CONTROLS JOB NAE ARCHITECT ENGINEER CONTRACTOR OCATION SUBITTA SHEET Form Number TS0000.10 Effective Date 6/08 Replaces Form TS0000.9 BASIC UNIT NO CONTROS CHARTED 'A' DIENSION INCUDES INET ADAPTER PROVIDED ON

More information

VariTrane VAV Terminal Unit. Single-Duct Series Fan-Powered Parallel Fan-Powered

VariTrane VAV Terminal Unit. Single-Duct Series Fan-Powered Parallel Fan-Powered VariTrane VV Terminal Unit Singleuct Series FanPowered Parallel FanPowered Contents VV System Overview VariTrane VV Terminal Unit Overview Model escription Singleuct Terminal Units Model escription FanPowered

More information

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals Product Data 5J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals 90 to 3900 Cfm Series Fan Box 5J,K,Q Parallel Fan Box 5M,N,R 5J,M 5K,N 5Q,R The 5J,M,K,N,Q,R units were

More information

SINGLE DUCT AIR TERMINAL UNITS

SINGLE DUCT AIR TERMINAL UNITS AIR terminal units AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units are at the core of

More information

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL Fan Powered Terminals VAV TERMINALS IOM FAN POWERED TERMINALS Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage is

More information

Product Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems

Product Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems Product Data AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems 45UC 35BF-R 42KC 45XC 35BF-D Features/Benefits Access Floor Systems can provide flexibility and economic

More information

IAQ. ROUND DUCT RETROFIT Model ARR

IAQ. ROUND DUCT RETROFIT Model ARR Non Fan Powered Units ROUND DUCT RETROFIT Model ARR IAQ External Insulation Standard The Carnes Model ARR offers low pressure drop, low sound levels, and valve characteristics which create stable control

More information

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals. Product Data 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals 90 to 3900 Cfm 45J,M 45K,N 45Q,R The 45J,M,K,N,Q,R units were designed to maintain accurate temperatures

More information

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View. Horizontal Low Profile oncealed with Plenum FU-RBHR-1.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041]

More information

Dual Duct Variable Air Volume Terminal (Model TDS)

Dual Duct Variable Air Volume Terminal (Model TDS) Product Bulletin Issue Date June 21st, 2005 Dual Duct Variable Air Volume Terminal (Model TDS) Model TDS terminals provide Variable Air Volume (VAV) control beyond the typical dual duct box. They are specifically

More information

Laboratory Room Single Duct Supply Air Terminal

Laboratory Room Single Duct Supply Air Terminal Technical Specification Sheet Document No. 149-319A June 24th, 2010 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The APOGEE Automation

More information

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional

More information

I Fan Powered Terminal Unit

I Fan Powered Terminal Unit I Fan Powered Terminal Unit VARIABLE VOLUME PARALLEL FLOW Fan Powered Terminal Unit Variable volume parallel flow Product Overview Variable Volume/Parallel Flow Fan Powered Terminal Units Honeywell parallel

More information

FCVC Series VERTICAL FAN COILS

FCVC Series VERTICAL FAN COILS VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

catalog SDR Single-Duct VAV Terminals

catalog SDR Single-Duct VAV Terminals catalog SDR Single-Duct VAV Terminals TABLE OF CONTENTS Features And Benefits...2 Standard Construction...6 Optional Construction...7 Standard And Optional Features...8 Application And Selection...9 Airflow

More information

C2-2. Table of Contents DUAL DUCT TERMINAL UNITS

C2-2. Table of Contents DUAL DUCT TERMINAL UNITS C2 UA UCT TERINA UNITS Table of Contents UA UCT TERINA UNITS This unit features a compact design for variable volume applications where blending of hot and cold air is not required. T This unit features

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

Dual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series

Dual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series Product Key UQ Ultra Quiet Product Selection Checklist 1] Select Unit Inlet Size based on control and acoustic parameters.

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI Air Terminal Units Models MQTH, MQFCI and MQFVI Catalog 903-1 Model MQTH Model MQFCI Model MQFVI Table of Contents Single Duct Air Terminal Units.... 3 Introduction....3 MQTH-500 Single Duct Air Terminal

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

FDCLP2 Constant Volume Series Flow, Low Profile

FDCLP2 Constant Volume Series Flow, Low Profile The Price low profile series fan powered terminal unit is an ideal product for use in typical series fan powered applications with limited ceiling space. The is designed for constant air volume applications,

More information

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification Date: October 22, 1999 Rev: 00 Doc. No. AG-LHK-01 Application Guide This Application Guide has been developed to introduce the LHK access floor fan powered terminal. In this Guide you will find a description

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also

More information

FN Fan-Coil Units High-Performance, Horizontal

FN Fan-Coil Units High-Performance, Horizontal FN Fan-Coil Units High-Performance, Horizontal Model FNX Exposed-Cabinet Dimensional Data Notes: 1. All dimensions are in inches [mm] and are +/- 1/8" [3 mm]. Metric values are soft conversions. 2. See

More information

VAV Variable Air Volume Terminal Units

VAV Variable Air Volume Terminal Units VAV Variable Air Volume Terminal Units VAV Terminal Units Contents Introduction 1 AN Series 2 AE Electric Reheat 4 A Hot ater Reheat 5 AFIN Fan Assist in Parallel 6 AFCN Fan Assist in Series 7 AFIE Fan

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

PERFORMANCE DATA Intermittent Volume (Parallel Flow), Standard Design

PERFORMANCE DATA Intermittent Volume (Parallel Flow), Standard Design FAN CURVES vs FAN SIZE A AS 05, 06, 07 1/6 H.P. Motor FAN SIZE B AS 06, 07, 08 1/6 H.P. Motor NOTES: 1. External Static Pressure (ESP) consists of down stream ductwork, coils, flex, duct, etc. 2. Pressure

More information

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

Product Data. 42D Ducted Fan Coil Air Conditioners cfm Product Data 42D Ducted Fan Coil Air Conditioners 600-2000 cfm Carrier s 42D series ducted fan coil units offer design and equipment location flexibility Choice of 5 models, each available in 8 sizes For

More information

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated

More information

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED Direct Drive, Draw-through Design Model Series 3FH Filter 1" (2) throwaway (standard) 2" (1) MERV 8 or MERV 13 pleated (optional) Multiple coil options: 3, 4,, 6 row cooling or heating coils 1 or 2 row

More information

AIR FLOW SOLUTIONS. MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit. MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit

AIR FLOW SOLUTIONS. MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit. MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit IOM 002 Effective 4/06 AIR FLOW SOLUTIONS Installation, Operation, & Maintenance MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit

More information

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model

More information

Zone Valves and Parts (Honeywell)

Zone Valves and Parts (Honeywell) 28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial

More information

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL

More information

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE

More information

RETROFIT TERMINAL UNITS

RETROFIT TERMINAL UNITS GENERAL PROUCT OVERVIEW Retrofit Terminal s Convert Constant Air Volume Systems to Variable Air Volume. Convert Constant Volume ual uct Systems to Variable Air Volume. Convert Multizone Systems to Variable

More information

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS INSTALLATION OPERATION & MAINTENANCE New Release Form 130.13-NOM4 (908) In conjunction with the use of these instructions, obtain and refer to the construction,

More information

Laboratory Room Single Duct Supply Air Terminal

Laboratory Room Single Duct Supply Air Terminal Technical Specification Sheet Document No. 149-319P25 July 28, 2017 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The Laboratory Room

More information

Product Catalog. VariTrane Products Single Duct/Dual Duct Units VDD, VCC, VCW, VCE VAV-PRC011M-EN. Variable-Air-Volume (VAV) System.

Product Catalog. VariTrane Products Single Duct/Dual Duct Units VDD, VCC, VCW, VCE VAV-PRC011M-EN. Variable-Air-Volume (VAV) System. Product Catalog VariTrane Products Single Duct/Dual Duct Units VDD, VCC, VCW, VCE Variable-Air-Volume (VAV) System EA RA OA supply fan PA cooling coil variablespeed drive VAV box thermostat SA March 2015

More information

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS BY JOHNSON CONTROLS INSTALLATION OPERATION & MAINTENANCE MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS New Release Form ET130.13-NOM4 (908) In conjunction with the use of these instructions, obtain

More information

Submittal 6 [152] 6 [152] 8 [203]

Submittal 6 [152] 6 [152] 8 [203] TVSR Vertical High Rise Recessed Stand lone Fan Coil Unit (Do not Include Risers See note ) Submittal FCU-TVS-R-1.0 03-01- 2 - Pipe Top Views 4 - Pipe Unit Size 03 & 04 0 & 0 10 & 20 [50] 24 [10] 1 ½ [419]

More information

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem / Series Characterized Control Valve, Spring ctuator Two-way and Three-way Valves with Chrome Plated rass all and rass Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: mbient Temp

More information

Installation/ Operation Maintenance. VariTrac Dampers

Installation/ Operation Maintenance. VariTrac Dampers Installation/ Operation Maintenance VariTrac Dampers June 2002 General These instructions do not cover all variations in systems nor provide for every possible contingency that may arise at a jobsite installation.

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

Submittal. THBP Horizontal Low Profile Plenum Return FCU-THBP Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal. THBP Horizontal Low Profile Plenum Return FCU-THBP Top View (Drain Pan Omitted) Bottom View. Front View. U-THBP-.0 03-0-8 THBP Horizontal Low Profile Plenum Return Top View (rain Pan Omitted) Bottom View ront View Left hand unit shown. ll dimensions are inches [millimeters]. Side View [8] 26 [6] [06] [270]

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

SPV / SDV Series SINGLE DUCT TERMINAL UNITS

SPV / SDV Series SINGLE DUCT TERMINAL UNITS SPV / SDV Series SINGLE DUCT Price single duct terminal units are designed to control the airflow rate of conditioned air into an occupied space with minimal pressure drop and low noise levels. An extensive

More information

FDU HOT WATER COILS COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) DOWNSTREAM HEATING COIL OUT

FDU HOT WATER COILS COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) DOWNSTREAM HEATING COIL OUT COIL DISCARGE COLLAR FDU OT WATER COILS OPT. CAD SECTION COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) DISCARGE COLLAR COIL ACCESS DOOR (CAD) 4.00 (102) X 6.75 (171) 3.500 (89) 6.500 (165) (SZ 10-40)

More information

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations. Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open

More information

Electric Furnace KF/KFS Series

Electric Furnace KF/KFS Series Electric Furnace KF/KFS Series KF/KFS 20 20 1 A B C D A: Series B: 20-208V 24-240V 48-480V C: Kilowatts D: 1 or 3-phase Heavy duty open-coil element Direct drive motor Up to 3-speed motor Standard 24 Volt

More information

SINGLE DUCT AIR TERMINAL UNITS

SINGLE DUCT AIR TERMINAL UNITS SINGLE DUCT AIR terminal units SINGLE DUCT AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units

More information

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 4 Construction Features... 5 Standard and Optional Features.... 7 Application and

More information

IOM 002 Effective 12/17 A I R D I S T R I B U T I O N M O D E L Q S T M O D E L Q P T M O D E L E S T

IOM 002 Effective 12/17 A I R D I S T R I B U T I O N M O D E L Q S T M O D E L Q P T M O D E L E S T IOM 002 Effective 12/17 A I R D I S T R I B U T I O N A I R F L O W S O L U T I O N S I n s t a l l a t i o n, O p e r a t i o n, & M a i n t e n a n c e M O D E L Q S T Q u i e t, S e r i e s ( C o n

More information

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE Low Power Consumption, Accessible, & FW and FL Fan-Coil Design Features Owners Owners can choose between a standard height (FW)

More information

ATT Series Adjustable PIC Valves 2 Way 1/2-1-1/2 ATT - AutoTouch Terminal

ATT Series Adjustable PIC Valves 2 Way 1/2-1-1/2 ATT - AutoTouch Terminal ½ -1½ - Pressure Independent ontrol Valve - Modulating control valve, dynamic balancing valve and differential pressure control valve in one body. Field adjustable, self-balancing, dynamic flow control

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Switches Selector Switches SW 786 155-118P25 G-3 Positioning Switch SW 141 155-117P25 G-5 Enthalpy Control Switch EE 141 155-054P25 G-7 Static Pressure

More information