Dual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series
|
|
- Octavia Hamilton
- 5 years ago
- Views:
Transcription
1 DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series Product Key UQ Ultra Quiet Product Selection Checklist 1] Select Unit Inlet Size based on control and acoustic parameters. 2] Select Control type (Pneumatic, Digital) based on system design. 3] Select Control Sequence based on system design. SP300 Velocity Pressure Sensors Price dual duct terminals are supplied with 3 airflow sensors on mixing models, and 2 airflow sensors on non-mixing models, to suit any potential control sequence without any field modifications. On mixing models, airflow sensors are supplied at both inlets PIC Controller and at the discharge outlet, while for nonmixing models airflow sensors are supplied at both inlets only. The SP300 multipoint velocity pressure sensor directs flow data to the controller. The velocity pressure signals are ampli fied for increased sensitivity and control response. In addition, the multiple sensing points and center averaging chamber provide a more repre sentative indication of air volume under varying flow conditions. For more information on the SP300 sensor, please refer to Page F39-F41. All Price terminals are available with factory supplied, installed and configured Price Intelligent Controllers (PIC). Price Intelligent Controller (PIC) The Price Intelligent Controller (PIC) is a universal DDC control package that offers a new level of zone control. An advanced and configurable proportional integral (PI) controller allows for exceptional user comfort and energy efficiency. Installation of the controller and thermostat is simple and error proof with RJ-45 (network type) connections to the thermostat. The PIC is available with several thermostat options allowing the designer to match the specific needs of the customer. Every model of thermostat has an RJ-12 service port allowing setup and configuration access without having to access the plenum. Features: Fast and error proof RJ-45 thermostat connections 24 VAC binary switched outputs field switchable between hot and common Analog (0-10 VDC) outputs configurable for heating, cooling, fan and auxiliary Price Intelligent Controller (PIC) Integrated actuator Field installable expansion modules for BACnet MS/TP and VAV flow sensing Pluggable terminal blocks for easy field wiring Diagnostic LED s showing status of each output including damper direction PIC Plug and Play F-185
2 DPS, DDS Series Controller Type Dimensional Data Model DPS8000 Model DDS5000 Multi-Point Inlet Sensor (gauge taps optional) Dimensional Data IP (in.)/si [mm] Unit cfm [L/s] Inlet Outlet Size Range*** Range*** A B C D E F L G [21 106] 4 [102]** 21 [533] 10 [254] 11 [279] 11 7 /8 [302] 7 7 /8 [200] 18 [457] 11 1 /2 [292] [30 165] 5 [127]** 21 [533] 10 [254] 11 [279] 11 7 /8 [302] 7 7 /8 [200] 18 [457] 11 1 /2 [292] [31-189] 6 [152] 21 [533] 10 [254] 11 [279] 11 7 /8 [302] 7 7 /8 [200] 18 [457] 9 1 /2 [241] [47-260] 7 [178] 21 [533] 10 [254] 11 [279] 11 7 /8 [302] 9 7 /8 [251] 18 [457] 9 1 /2 [241] [62-354] 8 [203] 21 [533] 10 [254] 11 [279] 11 7 /8 [302] 9 7 /8 [251] 18 [457] 9 1 /2 [241] [79-472] 9 [229] 25 [645] 12 1 /2 [318] 13 [330] 13 7 /8 [352] 12 3 /8 [314] 20 [508] 9 1 /2 [241] [ ] 10 [251] 25 [645] 12 1 /2 [318] 13 [330] 13 7 /8 [352] 12 3 /8 [314] 20 [508] 9 1 /2 [241] [ ] 12 [305] 29 [737] 15 [381] 15 [381] 15 7 /8 [403] 14 7 /8 [378] 28 [711] 9 1 /2 [241] [ ] 14 [356] 40 [1016] 17 1 /2 [445] 20 1 /8 [511] 19 7 /8 [505] 17 3 /8 [441] 40 3 /8 [1026] 4 3 /8 [111] [ ] 16 [406] 48 [1219] 18 [457] 24 1 /8 [613] 23 7 /8 [606] 17 7 /8 [454] 47 1 /8 [1197] 4 3 /8 [111] Notes: Internal insulation 3 /4 in. [19mm] dual density which meets requirements of NFPA 90A and UL gauge zinc-coated steel housing. Mechanically sealed and gasketed, leak-resistant construction. Range of maximum cfm [L/s] settings are for either hot or cold inlets. Gauge taps are standard. ** 6 in. diameter duct with 4 in. or 5 in. reducer. *** Range may vary based on controls and selected controls sequence. F-187
3 DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series Controller Type Liners - Terminal Casing Price offers an extensive Terminal Unit Liner System to address the issue of terminal unit insulation fibers entering the air stream. Each liner system offers benefits that are designed to meet applications with various lining and insulation requirements. SM Solid Metal Liner System This system integrates a fiberglass insulating material with a solid sheet metal liner constructed from zinc-coated steel. The solid metal liner system complies with the following industry standards and tests: UL 181 (Air Erosion) UL 181 (Mold Growth and Humidity) UL 723 (25/50) (Flame and Smoke) ASTM E 84 (25/50) (Flame and Smoke) ASTM C 665 (Fungi Resistance) ASTM C 1071 (Physical Properties) Solid metal liners offer the ultimate protection against exposure of fiberglass particles to the air stream. The fiberglass insulation is completely enclosed in metal all but eliminating the possibility of punctures exposing the fiberglass particles. This system is also resistant to moisture. The encased insulation pro vides thermal resistance, however, acoustic absorption of discharge noise is significantly reduced. The following thicknesses are available SM - 3 /4 in. [19] thick, R value=3.2 PM Perforated Metal Liner System This system integrates a fiberglass insulating material with a perforated metal liner constructed from coated steel. The edges are sealed with metal caps. The perforated metal liner system complies with the following industry standards and tests: UL 181 (Air Erosion) UL 181 (Mold Growth and Humidity) UL 723 (25/50) (Flame and Smoke) ASTM E 84 (25/50) (Flame and Smoke) ASTM C 665 (Fungi Resistance) ASTM C 1071 (Physical Properties) The metal perforated liner system provides effective protection against damage of the insulation while maintain ing some acoustic value. Small fiberglass particles could conceivably still escape through the perforations and moisture can also be exposed to the insulation. The following thicknesses are available PM - 3 /4 in. [19] thicks, R value = 3.2 AFPM Aluminum Foil with Perforated Metal Liner System This system integrates foil-faced fiberglass insulating material with a perforated metal liner. The edges are sealed with metal end caps to prevent particles from entering the air stream. The double liner system (aluminum foil/ SM PM perforated metal) complies with the following industry standards and tests: UL 181 (Air Erosion) UL 181 (Mold Growth and Humidity) UL 723 (25/50) (Flame and Smoke) ASTM E 84 (25/50) (Flame and Smoke) ASTM C 665 (Fungi Resistance) ASTM C 1071 (Physical Properties) The aluminum foil with perforated metal liner system provides effective protection against damage of the liner while maintaining some acoustic value. The aluminum foil prevents fiberglass particles from escaping through the perforations as well as resistance to moisture penetration. AFPM - 5 /8 in. [16] thicks, R-value =2.6 FF50 / FF Fiber Free Foam Insulation System This system integrates an engineered foam (FF50-1 /2 in. thick / FF - 3 /4 in. thick) which provides excellent insulating characteristics. The foam edges are self sealing due to the material s composition. The engineered foam meets the requirements of NFPA 90A complies with the following industry standards and tests: UL 181 (Air Erosion) UL 181 (Mold Growth and Humidity) UL 723 (25/50) (Flame and Smoke) ASTM E 84 (25/50) (Flame and Smoke) CAN/ULC M88 (Flame and Smoke) Fiber free foam insulation totally eliminates the risk of fiberglass particles entering the air stream while maintaining thermal resistance and acoustic absorption. An important advantage over other liner systems is that even scrapes or punctures will not expose fibers to the air stream. The foam also will not absorb water, reducing AFPM FF50 / FF FB (FF50) 1/2 (13) or (FF) 3/4 (19) the likelihood of mold or bacterial growth. Acoustic absorption of the foam insulation is equivalent to aluminum foil faced insulation. FB Foil Board Liner System This system integrates 4 lb. density rigid fiberglass insulating material with an aluminum foil liner. Exposed edges are coated with NFPA-90A approved sealant. The fiberglass insulation and aluminum foil liner complies with the following industry standards and tests: UL 181 (Air Erosion) UL 181 (Mold Growth and Humidity) UL 723 (25/50) (Flame and Smoke) ASTM E 84 (25/50) (Flame and Smoke) ASTM C 665 (Fungi Resistance) ASTM C 1071 (Physical Properties) Acoustic absorption of aluminum foil lined insulation is reduced compared to standard unlined units. The aluminum foil liner is non porous, thereby protecting the insulation from moisture. Damage to the liner can expose fiberglass particles to the air stream. The following thicknesses are available FB - 5 /8 in. [16] thicks, R-value =2.6 F-191
4 DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series Controller Type Cleanroom Construction CRAF Cleanroom Aluminum Foil System This system integrates a 5 /8 in. [16] thick 4lb density fiberglass insulating material with an aluminum foil facing. All edges are sealed with metal endcaps and corner angles to prevent particles from entering the air stream. The liner s integrity is maintained where the damper shaft penetrates the insulation by a flanged nylon bushing. To reduce risk of liner damage during installation, sealed-in-place s-cleats are provided at the discharge collar. The inlet duct is sealed to the internal insulation with mold resistant caulking which meets ASTM D The fiberglass insulation and aluminum foil liner complies with the following industry standards and tests: UL 181 (Air Erosion) UL 181 (Mold Growth and Humidity) UL 723 (25/50) (Flame and Smoke) ASTM E 84 (25/50) (Flame and Smoke) ASTM C 665 (Fungi Resistance) ASTM C 1071 (Physical Properties) Acoustic absorption of aluminum foil lined insulation is reduced compared to standard unlined units. The aluminum foil liner is non porous, thereby protecting the insulation from moisture. The smooth surface of the liner reduces the risk of micro-organisms being trapped in the material and also facilitates cleaning. Damage to the liner can expose fiberglass particles to the air stream. CRWF Cleanroom Woven Fabric System This system integrates fiberglass insulating material with a woven fabric liner. All edges are sealed with a metal end cap and corner angle to prevent particles from entering the air stream. The liner s integrity is maintained where the damper shaft penetrates the insulation by a flanged nylon bushing. To reduce risk of liner damage during installation, sealed-in-place s-cleats are provided at the discharge collar. The inlet duct is sealed to the internal insulation with mold resistant caulking which meets ASTM D The fiberglass insulation and fabric liner complies with the following industry standards and tests: UL 181 (Air Erosion) UL 181 (Mold Growth and Humidity) UL 723 (25/50) (Flame and Smoke) ASTM E 84 (25/50) (Flame and Smoke) ASTM C 665 (Fungi Resistance) ASTM C 1071 (Physical Properties) The woven fabric liner provides acoustic absorption equivalent to aluminum foil faced insulation with slightly improved attenuation at high frequencies. The fabric is more porous than aluminum foil, therefore moisture can be absorbed into the insulation. If the liner is damaged, fiberglass particles can be exposed to the air stream. The woven fabric liner has been specified in certain areas for many years and has a proven track record in health care applications, R value = 2.6. CRAF CRWF Fiberglass with woven fabric facing F-193
5 DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series Controller Type Control Sequences Typical Dual Duct Control Settings Diagram 1 In this example, the hot deck and the cold decks are set for unequal calibrated maximum air volumes. When the thermostat is calling for maximum heat, the hot deck damper opens to the calibrated maximum air volume limit, while the cold deck closes to the full shut-off position. Both the hot deck and the cold deck in this example are calibrated for a minimum flow rate of zero. As room temperature rises following a demand for full heating, the total air volume of the assembly ap proach es zero. If the room temperature continues to rise, the cold deck damper will begin to open. The cold deck damper will continue to open until either the thermostat is satisfied or the cold deck calibrated maximum air volume setting is reached. Diagram 3 This diagram illustrates a constant volume application. The hot and cold deck calibrated maximum air volumes are set for the same maximum airflow rate. At a thermostat signal for maximum cooling, the cold deck flow will be at maximum set-point and the hot deck flow at zero. As the room temperature begins to decrease, the thermostat signal will decrease reducing the flow through the cold deck. The hot deck controller begins to open the hot deck damper to maintain a constant discharge volume. As the cold deck flow is reduced further, the hot deck flow increases until the cold deck is shut off. The proportions of hot and cold air are indicated by the broken lines. Flow Sensor Orientation Dual Duct Terminal is supplied with SP300 flow sensors on both inlet ducts. Also for all models except for DPV/DDV one downstream total flow SP300 sensor is always mounted at the discharge. For pneumatic and electronic sequences the cold deck inlet sensor and downstream total flow sensors are utilized for all standard constant and variable volume configurations. The hot deck inlet sensor is not used. When controls are supplied by factory or are field mounted, the appropriate sensors required will depend on the model of controls and application. To accommodate all variations and allow future field modification, both inlet and downstream sensors are supplied as standard. 3 1 Diagram 2 In this example, the hot and cold decks are again set for unequal calibrated maximum air volumes, however a minimum air volume is also provided. Mixing of the hot and cold deck flows occurs at the minimum setting. The proportion of hot and cold air are indicated by the broken lines. As room temperature decreases, the cold deck is modulated from maximum to minimum set-point. A further decrease in room temperature causes the hot deck damper to open as the cold deck damper closes. A constant minimum airflow is maintained during mixing. On a call for full heat, the cold deck closes and the hot deck increases to its maximum set-point. Diagram 4 This diagram illustrates a constant volume application similar to diagram three, however the cold deck is calibrated with a minimum set-point of 20%. When the thermostat calls for full heating, the total supply volume will consist of 20% cold deck and 80% hot deck. The proportions of hot and cold air are indicated by the broken lines. 4 2 F-194
6 DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series Controller Type Selection Guidelines When sizing dual duct terminal units, the table of calibrated air volume ranges should be consulted to verify that the air quantity proposed for a given unit size, is compatible with the capabilities of the con troller. To illustrate, we will comment with reference to the control diagrams on page F222. In Diagrams 1 4 for the unit size selected, the maximum cold deck air volume pro pos ed must fall within the limits of the calibrated maximum air volume range as listed in the table for that unit size. Sim i larly, the hot deck air volume proposed must also fall within these same air vol ume range limits. If both air volumes pro posed do not fall within these limits, con sideration should be given to select ing a smaller unit size and/or modifying the proposed air volumes to bring them within the listed limits. In Diagram 2, the mixed air volume is equal to the minimum hot and cold deck value. This volume must fall within the minimum values listed in the table. In Diagram 4, the minimum cold deck value must fall within the minimum values listed in the table. A standard unit is supplied with both the hot and the cold inlets of the same size. Where there is a large difference between the maximum hot and the maximum cold air quantities, and the smaller maximum air quantity is at or below the lower limit for the calibrated maximum air volume range for that unit size unequal inlets should be considered. Each inlet would then be sized to accommodate the maximum air quantity required through that inlet. When unequal inlet sizes are used, the casing size will be governed by the larger inlet size, in accordance with the dimensional table on pages F215-F219. Calibrated Air Volume Ranges Pneumatic (CP101) Controller Unit HD and CD HD and CD HD and CD HD and CD Size L/S Min. L/S Max. cfm Min. cfm Max Calibrated Air Volume Ranges Digital Controls Unit Size L/s Min-Max cfm Min-Max DPQ Notes: Factory calibrated controls must be selected within the above flow range limits. A minimum value of zero is also available. When an auxiliary flow setting is specified, the value must be greater than the minimum setting and within the range limits. On controls mounted by Price but supplied by others, the air volume ranges are guidelines only. *Selection of airflow limits below the listed values is not recommended. Stability and accuracy may not be acceptable at lower than recommended airflow limits. The actual performance will vary depending on the terminal unit controls supplied. *Minimum airflow limit is based on min.02 in. w.g. differential pressure signal from airflow sensor. Selection of airflow limits below the listed values is not recommended. Stability and accuracy may not be acceptable at lower than recommended airflow limits. The actual performance will vary depending on the terminal unit controls supplied. Maximum airflow limit is based on max 1.0 in. w.g. differential pressure signal from the airflow sensor. F-195
7 DPS, DDS Series Controller Type Standard Model Typical Selection Guide Discharge NC Basic Unit Ps Across Unit Radiated NC Basic Unit Ps Across Unit Min. Ps Across Unit Min. Pt. Unit Airflow Basic Unit Basic Unit 0.5 in.w.g 1.0 in.w.g 1.5 in.w.g 3.0 in.w.g 0.5 in.w.g 1.0 in.w.g 1.5 in.w.g 3.0 in.w.g Size cfm L/s in.w.g Pa in.w.g Pa 125Pa 1250Pa 375Pa 750Pa 125Pa 250Pa 375Pa 750Pa * * * * * * * * * * * * * * * * * * * * * * * * * * * * Performance Notes: 1. NCs are derived from sound power levels, which are obtained in accordance with AHRI Standard and ASHRAE Standard NCs are derived from sound power levels which include duct end corrections per AHRI Standard Please refer to page F25 for more details. 3. Blank spaces (--) indicate NCs less than Asterisks (*) indicate minimum static pressure of the unit exceeds the minimum operating pressure across the unit. 5. Airflow is given in L/s and cfm. 6. ΔPs is the difference in static pressure from inlet to discharge of the unit. 7. ΔPs for terminal units with electric coil is equal to basic unit. Resistance of the coil elements is negligible. 8. ΔPt is the difference in total pressure from inlet to discharge of the unit. 9. For a detailed explanation of static and total pressure drop refer to page F Pressure is given in Pa and in. w.g. 11. NC values are calculated based on typical attenuation values outlined in Appendix E, AHRI Standard , A Procedure for Estimating Occupied Space Sound Levels in the Application of Air Terminals and Air Outlets. Typical Attenuation Values: Radiated Sound Total Deduction Mid Frequency, Hz All Sizes Discharge Sound Total Deduction Mid Frequency, Hz < 300 cfm cfm > 700 cfm F-196
8 DPS, DDS Series Controller Type Aluminum Foil Lined Construction, CRAF Typical Selection Guide No Lined Ductwork Discharge NC Radiated NC Basic Unit Basic Unit Min. Ps Across Unit Min. Pt. Ps Across Unit Ps Across Unit Unit Airflow Basic Unit Basic Unit 0.5 in.w.g 1.0 in.w.g 1.5 in.w.g. 3.0 in.w.g. 0.5 in.w.g 1.0 in.w.g 1.5 in.w.g. 3.0 in.w.g. Size cfm L/s in.w.g. Pa in.w.g. Pa 125 Pa 250 Pa 375 Pa 750 Pa 125 Pa 250 Pa 375 Pa 750 Pa * * * * * * * * * * * * * * * * * * * * * * * * * * * * Performance Notes: 1. NCs are derived from sound power levels, which are obtained in accordance with AHRI Standard and ASHRAE Standard NCs are derived from sound power levels which include duct end corrections per AHRI Standard Please refer to page F25 for more details. 3. Blank spaces (--) indicate NCs less than Asterisks (*) indicate minimum static pressure of the unit exceeds the minimum operating pressure across the unit. 5. Airflow is given in L/s and cfm. 6. ΔPs is the difference in static pressure from inlet to discharge of the unit. 7. ΔPs for terminal units with electric coil is equal to basic unit. Resistance of the coil elements is negligible. 8. ΔPt is the difference in total pressure from inlet to discharge of the unit. 9. For a detailed explanation of static and total pressure drop refer to page F Pressure is given in Pa and in. w.g. 11. NC values are calculated based on procedures outlined in AHRI Standard , A Procedure for Estimating Occupied Space Sound Levels in the Application of Air Terminals and Air Outlets. Radiated Sound is based on a 5 /8 in. mineral fiber tile ceiling per AHRI , Appendix E typical attenuation values. Total Deduction Mid Frequency, Hz All Sizes Discharge Sound is based on environmental effect, end reflection, flex duct effect, space effect, and sound power division. No deductions for lined duct are included. These calculations are not covered by AHRI Appendix E. Total Deduction Mid Frequency, Hz < 300 cfm cfm > 700 cfm F-197
9 DPS, DDS Series, DPQ, DDQ Series DPM, DDM Series, DPUQ,DDUQ Series Controller Type Typical Selection Guide NC levels presented in the Typical Selection Guide are based on typical attenuation values as outlined in AHRI Standard , Appendix E. AHRI Standard , Appendix E provides typical sound attenuation values for air terminal discharge sound and air terminal radiated sound. The typical attenuation values are recommended for use by manufacturers to estimate application sound levels. In product catalogs the end use environments are not known and the factors presented in AHRI Standard are provided as typical attenuation values. Use of these values will allow better comparison between manufacturers and give the end user a value which will be expected to be applicable for many types of spaces. Following is a detailed description of the typical attenuation values used to determine NC levels. Radiated Sound Table E-1 of Appendix E provides typical radiated sound attenuation values for three types of ceilings: Type 1 Glass Fiber; Type 2 Mineral Fiber; Type 3 Solid Gypsum Board. Since Mineral Fiber tile ceilings are the most common construction used in commercial buildings, the attenuation values in the Typical Selection Guide are based on Type 2 Mineral Fiber. The following table provides the calculation method for the radiated sound total attenuation values based on AHRI Standard Mid Frequency, Hz Environmental Effect Ceiling/Space Effect Total Attenuation Deduction The ceiling/space effect assumes the following conditions: 1. 5/8 in. tile, 20 lb/ft 3 density. 2. The plenum is at least 3 ft deep. 3. The plenum space is either wide (over 30 ft) or lined with insulation. 4. The ceiling has no significant penetration directly under the unit. Discharge Sound Table E-1 of Appendix E provides typical discharge sound attenuation values for three sizes of terminal units. 1. Small box defined as a unit with discharge duct of approximately 8 in. x 8 in. and capacity less than 300 cfm. 2. Medium box defined as a unit with discharge duct of approximately 12 in. x 12 in. and capacity between cfm. 3. Large box defined as a unit with discharge duct of approximately 15 in. x 15 in. and capacity of greater than 700 cfm. The following tables provide the calculation method for the discharge sound and total attenuation values based on AHRI Standard Small Box Mid Frequency, Hz Max Airflow < 300 cfm Environmental Effect ft [1.5 m] Duct Lining End Reflection ft [1.5 m], 8 in [200 mm] Flex Duct Space Effect Sound Power Division Total Attenuation Deduction Medium Box Mid Frequency, Hz Airflow cfm Environmental Effect ft [1.5 m] Duct Lining End Reflection ft [1.5 m], 8 in [200 mm] Flex Duct Space Effect Sound Power Division Total Attenuation Deduction Large Box Mid Frequency, Hz Airflow > 700 cfm Environmental Effect ft [1.5 m] Duct Lining End Reflection ft [1.5 m], 8 in [200 mm] Flex Duct Space Effect Sound Power Division Total Attenuation Deduction For a complete explanation of the attenuation factors and the procedures for calculating room NC levels, please refer to AHRI Standard NC vs. Sound Power Levels Compare Them Carefully Price represents the sound performance data for the DPS, DDS/DPQ, DDQ/DPM, DDM series of dual duct terminals in two manners. The laboratory attained discharge and radiated sound power levels for each unit at various flows and inlet static pressures is presented in the Acoustical Data tables. This data is derived in accordance with AHRI Standard 880 and shows the 'raw' sound power levels of the terminal in the second through seventh octave bands with NO attenuation allowances. This data includes AHRI standard ratings which are on record with the Air-Conditioning Refrigeration Institute. Price also offers this Typical Application and Selection Guide to assist you in selecting the proper size and configuration of terminal for your needs. The attenuation allowances listed are based on F-202 values suggested in AHRI Standard , Appendix E. The suggested attenuation allowances are intended to be representative of typical jobsite construction. If your conditions differ significantly from these it is recommended you utilize the sound power level data on pages F149-F150 and the procedures outlined in AHRI Standard If the NC levels listed in the Price catalog are being compared to other manufacturers cataloged NC information, a careful review of the other manufacturers attenuation allowances must be made. If allowances other than recommended AHRI Standard , Appendix E are used, a fair comparison of NC levels cannot be performed.
10 DPS, DDS Series Controller Type Standard Model Discharge Sound Data Sound Power Levels Lw db re Watts 0.5 in. w.g. [125 Pa] 1.0 in. w.g. [250 Pa] 1.5 in. w.g. [375 Pa] 3.0 in. w.g. [750 Pa] Unit Airflow Size L/s cfm * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Performance Notes: 1. Test data obtained in accordance with AHRI Standard and ASHRAE Standard Sound power levels include duct end corrections per AHRI Standard Please refer to page F25 for more details. 3. Airflow given in L/s and cfm. 4. Pressure is given in Pa and in.w.g. 5. AHRI certified data is highlighted in blue. All other data are application ratings. 6. Application ratings are outside the scope of the AHRI 880 Certification Program. 7. Asterisks (*) indicate minimum static pressure of the unit exceeds the minimum operating pressure across the unit. F-203
11 DPS, DDS Series Controller Type Standard Model Radiated Sound Data Sound Power Levels Lw db re Watts 0.5 in. w.g. [125 Pa] 1.0 in. w.g. [250 Pa] 1.5 in. w.g. [375 Pa] 3.0 in. w.g. [750 Pa] Unit Airflow Size L/s cfm * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Performance Notes: 1. Test data obtained in accordance with AHRI Standard and ASHRAE Standard Sound power levels include duct end corrections per AHRI Standard Please refer to page F25 for more details. 3. Airflow given in L/s and cfm. 4. Pressure is given in Pa and in.w.g. 5. AHRI certified data is highlighted in blue. All other data are application ratings. 6. Application ratings are outside the scope of the AHRI 880 Certification Program. 7. Asterisks (*) indicate minimum static pressure of the unit exceeds the minimum operating pressure across the unit. 8. Dashes (--) indicate sound power levels below for each octave band; values below these sound power levels are considered below significance per AHRI 880. F-204
12 DPS, DDS Series Controller Type Aluminum Foil Lined Construction, CRAF Discharge Sound Data Sound Power Levels Lw db re Watts 0.5 in. w.g. [125 Pa] 1.0 in. w.g. [250 Pa] 1.5 in. w.g. [375 Pa] 3.0 in. w.g. [750 Pa] Unit Airflow Size L/s cfm * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Performance Notes: 1. Test data obtained in accordance with AHRI Standard and ASHRAE Standard Sound power levels include duct end corrections per AHRI Standard Please refer to page F25 for more details. 3. Airflow given in L/s and cfm. 4. Pressure is given in Pa and in.w.g. 5. All data are application ratings. Application ratings are outside the scope of the AHRI 880 Certification Program. 6. Asterisks (*) indicate minimum static pressure of the unit exceeds the minimum operating pressure across the unit. F-205
13 DPS, DDS Series Controller Type Aluminum Foil Lined Construction, CRAF Radiated Sound Data Sound Power Levels Lw db re Watts 0.5 in. w.g. [125 Pa] 1.0 in. w.g. [250 Pa] 1.5 in. w.g. [375 Pa] 3.0 in. w.g. [750 Pa] Unit Airflow Size L/s cfm * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Performance Notes: 1. Test data obtained in accordance with AHRI Standard and ASHRAE Standard Sound power levels include duct end corrections per AHRI Standard Please refer to page F25 for more details. 3. Airflow given in L/s and cfm. 4. Pressure is given in Pa and in.w.g. 5. All data are application ratings. Application ratings are outside the scope of the AHRI 880 Certification Program. 6. Asterisks (*) indicate minimum static pressure of the unit exceeds the minimum operating pressure across the unit. 7. Dashes (--) indicate sound power levels below for each octave band; values below these sound power levels are considered below significance per AHRI 880. F-206
SPV / SDV Series SINGLE DUCT TERMINAL UNITS
SPV / SDV Series SINGLE DUCT Price single duct terminal units are designed to control the airflow rate of conditioned air into an occupied space with minimal pressure drop and low noise levels. An extensive
More informationSPVQ / SDVQ Series QUIET SINGLE DUCT TERMINAL UNIT
Patented SPVQ / SDVQ Series QUIET SINGLE DUCT TERMINAL UNIT In an era of increasing IAQ and noise concerns, this innovative product is specifically designed to meet the challenges headon. Certified assemblies
More informationFan Powered Terminal Units FPV, FDV Series Variable Volume Parallel Flow
Recommended Air Volume Ranges CP 101 Unit Size L/s Min.* L/s Max. cfm Min.* cfm Max. 6 31 212 66 450 8 62 378 132 800 10 104 637 221 1350 12 146 991 310 2100 14 207 1416 439 3000 16 268 1888 568 4000 CP
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.
ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.
More informationSINGLE DUCT AIR TERMINAL UNITS
SINGLE DUCT AIR terminal units SINGLE DUCT AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units
More informationSINGLE DUCT AIR TERMINAL UNITS
AIR terminal units AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units are at the core of
More informationFPV, FDV Series Variable Volume Parallel Flow
Product Overview Variable Volume/Parallel Flow Fan Powered Terminal s With the variable volume model, the conditioned primary air does not pass through the fan. The primary air section and the recirculating
More informationFAN POWERED TERMINAL UNITS
Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and
More informationPH SERIES SINGLE DUCT ATU PERFORMANCE DATA
PH SERIES SINGLE DUCT ATU PERFORMAE DATA The Performance Aire PH Series is the simplest and most widely used VAV terminal unit. Its basic components are an insulated sheet metal box, round inlet damper,
More informationFAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES
FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing
More information500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)
500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage
More informationProduct Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm
Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA
More informationCatalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI
Air Terminal Units Models MQTH, MQFCI and MQFVI Catalog 903-1 Model MQTH Model MQFCI Model MQFVI Table of Contents Single Duct Air Terminal Units.... 3 Introduction....3 MQTH-500 Single Duct Air Terminal
More informationSINGLE DUCT TERMINAL UNITS
www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product
More informationHigh Performance Fan Coils FCHG Genesis Series Horizontal
Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct
More information500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)
500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to
More informationProduct Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm
Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional
More informationVariable Air Volume (VAV) Pressure Independent Control
VAV Terminal Units Asli Variable Air Volume (Vav) Terminal Units are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of conditioned
More information500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)
500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5
More informationRETROFIT TERMINAL UNITS
GENERAL PROUCT OVERVIEW Retrofit Terminal s Convert Constant Air Volume Systems to Variable Air Volume. Convert Constant Volume ual uct Systems to Variable Air Volume. Convert Multizone Systems to Variable
More informationIAQ. ROUND DUCT RETROFIT Model ARR
Non Fan Powered Units ROUND DUCT RETROFIT Model ARR IAQ External Insulation Standard The Carnes Model ARR offers low pressure drop, low sound levels, and valve characteristics which create stable control
More informationPERFORMANCE DATA Intermittent Volume (Parallel Flow), Standard Design
FAN CURVES vs FAN SIZE A AS 05, 06, 07 1/6 H.P. Motor FAN SIZE B AS 06, 07, 08 1/6 H.P. Motor NOTES: 1. External Static Pressure (ESP) consists of down stream ductwork, coils, flex, duct, etc. 2. Pressure
More informationIAQ. Model AVC. SINGLE DUCT VAV Model AVC
NON FAN POWERED UNITS SINGLE DUCT VAV Model AVC Model AVC The Carnes Model AVC is available as a basic control unit with open end discharge, with an optional multi-discharge adapter module, or sound attenuator
More informationVariable Air Volume Dampers
OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control
More informationVAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD
VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL
More informationLaboratory Room Single Duct Supply Air Terminal
Technical Specification Sheet Document No. 149-319A June 24th, 2010 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The APOGEE Automation
More informationFDCLP2 Constant Volume Series Flow, Low Profile
The Price low profile series fan powered terminal unit is an ideal product for use in typical series fan powered applications with limited ceiling space. The is designed for constant air volume applications,
More informationI Fan Powered Terminal Unit
I Fan Powered Terminal Unit VARIABLE VOLUME PARALLEL FLOW Fan Powered Terminal Unit Variable volume parallel flow Product Overview Variable Volume/Parallel Flow Fan Powered Terminal Units Honeywell parallel
More informationProduct Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm
Product Data 35E Single Duct Terminal Units for Variable Air Volume Systems Nominal 45 to 7100 cfm Single duct variable air volume (VAV) terminal units provide: 22-gage galvanized steel, unit casing lined
More informationB. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.
PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationsingle / dual duct terminals
PERFORANCE DATA RECOENDED PRIARY AIR CF RANGES / ALL TERINALS Control Types: PESV / Pneumatic AESV / Analog Electronic DESV / Digital Electronic QUICK SELECTION PROCEDURE 1. Select unit inlet size based
More informationD2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS
D2 RETROFIT/YPASS TERMINA UNITS Table of Contents RETROFIT/YPASS TERMINA UNITS RVE This retrofit terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable
More informationLaboratory Room Single Duct Supply Air Terminal
Technical Specification Sheet Document No. 149-319P25 July 28, 2017 Laboratory Room Single Duct Supply Air Terminal Features Figure 1. Laboratory Room Single Duct Supply Air Terminal. The Laboratory Room
More informationSECTION AIR TERMINAL UNITS
SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,
More informationVAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE
TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also
More informationIAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW
SINGLE DUCT w/hot WATER HEAT Model AVW Model AVW The Carnes Model AVW is available as a basic control unit with hot water reheat and open end discharge, with an optional sound attenuator module, and optional
More informationSDL Single-Duct, Low-Height, VAV Terminals
SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely
More informationcatalog SDL Single-Duct, Low-Height, VAV Terminals
catalog SDL Single-Duct, Low-Height, VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 3 Construction Features... 4 Standard and Optional Features.... 5 Dimensional and Weight Data....
More informationfan powered terminals
PTFS-F, ATFS-F, DTFS-F / AIRFLOW VS. DOWSTREAM STATIC PRESSURE TFS-F Size B 650 600 550 450 350 250 200 1 1200 1100 600 TFS-F Size C 150 TFS-F Size D 2 TFS-F Size E 1 2600 1 1 1600 1 1 1 1200 1100 2 2
More informationC2-2. Table of Contents DUAL DUCT TERMINAL UNITS
C2 UA UCT TERINA UNITS Table of Contents UA UCT TERINA UNITS This unit features a compact design for variable volume applications where blending of hot and cold air is not required. T This unit features
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 23 3600 - AIR TERMINAL DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fan-powered air terminal units/devices. 2. Shut off air terminal units/devices. 3. Dual duct terminal units/devices.
More informationSINGLE DUCT TERMINAL UNITS 30X/HQX SERIES
30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an
More informationcatalog SDL Single-Duct, Low-Height, VAV Terminals
catalog SDL Single-Duct, Low-Height, VAV Terminals Catalog: ET130.13-EG2 (708) TABLE OF CONTENTS Single-Duct, Low-Height VAV Terminals Features and Benefits....................... 2 Controls..................................
More informationAIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT
ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN
More informationSTR Circular VAV Terminal Units
STR Circular VAV ASLI Circular Variable Air Volume (STR) Terminal s are volume flow rate controller for supply air on variable air volume system. These units are designed to control the airflow rate of
More informationTSS Single-Duct VAV Terminals
TSS Single-Duct VAV Terminals Model TSS construction features Standard Construction Mechanical-lock construction ensures lowest possible casing leakage Roll-formed inlet collar with integral stiffening
More informationProduct Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems
Product Data AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems 45UC 35BF-R 42KC 45XC 35BF-D Features/Benefits Access Floor Systems can provide flexibility and economic
More informationcatalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals
catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals TABLE OF CONTENTS Features and Benefits.... 2 Controls.... 4 Construction Features... 5 Standard and Optional Features.... 7 Application and
More informationcatalog SDR Single-Duct VAV Terminals
catalog SDR Single-Duct VAV Terminals TABLE OF CONTENTS Features And Benefits...2 Standard Construction...6 Optional Construction...7 Standard And Optional Features...8 Application And Selection...9 Airflow
More informationLaboratory Exhaust Air Terminal
Laboratory Exhaust Air Terminal Page 1 of 11 Figure 1. Laboratory Exhaust Air Terminal. The APOGEE Automation Laboratory Room Exhaust Air Terminal is an industrial grade, easy-to-install, prepackaged airflow
More informationDual Duct Variable Air Volume Terminal (Model TDS)
Product Bulletin Issue Date June 21st, 2005 Dual Duct Variable Air Volume Terminal (Model TDS) Model TDS terminals provide Variable Air Volume (VAV) control beyond the typical dual duct box. They are specifically
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-23 36 00.00 40 (May 2016) ----------------------------------- Preparing Activity: NASA Superseding UFGS-23 36 00.00 40 (February 2011) UFGS-23 36 00 (November 2010) UNIFIED
More informationcatalog VFR Parallel Flow, Fan-Powered, VAV Terminals
catalog VFR Parallel Flow, FanPowered, VAV Terminals TABLE OF CONTENTS Features and Benefits... 2 Controls... 4 Construction Features... 5 Standard and Optional Features... 7 Application and Selection....
More informationcatalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals
catalog VFR Parallel Flow, FanPowered, 50/60 Hz VAV Terminals TABLE OF CONTENTS Features and Benefits...2 Controls...4 Construction Features...5 Standard and Optional Features...7 Application and Selection....8
More informationTechnical information
6-8 Application Rectangular NK and NL types are pressure-independent VAV and CAV air volume control terminals. The terminals are designed particularly for systems with large air volumes and duct sizes
More informationFCVC Series VERTICAL FAN COILS
VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,
More informationHORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED
Direct Drive, Draw-through Design Model Series 3FH Filter 1" (2) throwaway (standard) 2" (1) MERV 8 or MERV 13 pleated (optional) Multiple coil options: 3, 4,, 6 row cooling or heating coils 1 or 2 row
More informationVARYCONTROL VAV Dual Duct Terminal Boxes
5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk
More informationFan - Powered Terminal Unit Series Flow
5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone
More informationVAV TERMINAL UNITS. VVD VAV Diffusers
Introduction ASLI VAV diffusers, VVD are variable air volume diffuser for supply air in variable air volume system. In many conventional HVAC systems, multiple work spaces are controlled by a single thermostat.
More informationPIM Pressure Independent Module
PIM Pressure Independent Module PIM : Product Overview BENEFITS AT A GLANCE QUIET VAV DIFFUSER OPERATION The PIM Pressure Independent Module is a modulating static pressure controller/actuator that allows
More informationcatalog CFRQ, Extra Quiet Series Flow, Constant Volume Fan Powered VAV Terminals
catalog CFRQ, Extra Quiet Series Flow, Constant Volume Fan Powered VAV Terminals TABLE OF CONTENTS Features And Benefits... 2 Construction Features... 4 Standard & Optional Features... 6 Application And
More informationcatalog VFL Parallel Fan-Powered, Low-Height, VAV Terminals
catalog VFL Parallel FanPowered, LowHeight, VAV Terminals TABLE OF CONTENTS Features And Benefits...2 Construction Features...4 Standard And Optional Features...6 Application And Selection...7 Application
More informationcatalog CFR Series Fan-Powered, VAV Terminals
catalog CFR Series Fan-Powered, VAV Terminals TABLE OF CONTENTS Features and Benefits...2 Construction Features...4 Standard And Optional Features...6 Application Selection...7 Application and Selection....8
More informationNV series. Induction VAV air volume control terminals
NV series Induction VAV Description Table of contents Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model overview / dimensions 4-5 Sound data NVOAOOB...
More informationengineering guide TCS Series Fan-Powered, VAV Terminals
engineering guide TCS Series Fan-Powered, VAV Terminals FORM 130.13-EG4 (908) TABLE OF CONTENTS Series Fan-Powered, VAV Terminals Features and Benefits....................... 2 Construction Features.......................
More informationLMHS BASIC UNIT NO CONTROLS
JOB NAE ARCHITECT ENGINEER CONTRACTOR OCATION SUBITTA SHEET Form Number TS0000.10 Effective Date 6/08 Replaces Form TS0000.9 BASIC UNIT NO CONTROS CHARTED 'A' DIENSION INCUDES INET ADAPTER PROVIDED ON
More informationFan-Powered Parallel
Table of Contents Model Number Description 76 Selection Procedure 77-79 General Data Setting Guidelines 80 Performance Data Pressure Requirements 81 Performance Data Fan Curves 82-85 Performance Data Hot
More informationUniversity of Delaware
SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section
More informationProduct Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.
Product Data 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals 90 to 3900 Cfm 45J,M 45K,N 45Q,R The 45J,M,K,N,Q,R units were designed to maintain accurate temperatures
More informationHealthcare Solutions Room Pressure Monitors and Controls
Healthcare Solutions Room Pressure Monitors and Controls TOUCHSCREEN ROOM PRESSURE MONITOR The Touchscreen Room Pressure Monitor (PMT) provides precise room pressure monitoring for critical spaces such
More informationNR series. Circular CAV air volume control terminals with system powered mechanical regulator
series Circular CAV air volume control terminals Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 overview / dimensions 4-5
More informationEGG CRATE RETURN GRILLE
80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationto obtain the specified voids due
ARABIAN THERMAL AIRE INDUSTRIES NEW RANGE OF TESTED & CERTIFIED SOUND ATTENUATORS Arabian Thermal Aire Industries PO Box 1125, Jubail Industrial City, Saudi Arabia -319611 Tel: +966133415857 Fax: +9661334116311
More informationHOW TO SPECIFY SDV UNITS
HOW TO SPECIFY SDV UNITS MODEL UNIT CONFIG LINER CASING OPTIONS CONST. SIDE INLET SIZE DISCHARGE OPTIONS CONTROL TYPE UNIT ACCESSORIES HEAT kw ELECTRIC HEAT ACCESSORIES SCR HEAT ACCESSORIES SDV 0 - Standard
More informationApplication Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification
Date: October 22, 1999 Rev: 00 Doc. No. AG-LHK-01 Application Guide This Application Guide has been developed to introduce the LHK access floor fan powered terminal. In this Guide you will find a description
More informationSPD SQUARE PLAQUE DIFFUSER
SQUARE PLAQUE DIFFUSER The (SPD) has a flush appearance, making it ideal for architecturally-conscience commercial spaces, and provides industry-leading low pressure drop and sound generation with a 360
More informationProduct Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals
Product Data 5J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals 90 to 3900 Cfm Series Fan Box 5J,K,Q Parallel Fan Box 5M,N,R 5J,M 5K,N 5Q,R The 5J,M,K,N,Q,R units were
More informationQuiet-Duct Conic-Flow Silencers Section Specifications
Quiet-Duct Conic-Flow Silencers Section 15000 Specifications 1.01 General A. Furnish and install Conic-Flow (tubular) silencers of the types and sizes shown on the plans and/or listed in the schedule.
More informationPIM Pressure Independence Module
PIM Pressure Independence Module PIM : Product Overview BENEFITS AT A GLANCE QUIET VAV DIFFUSER OPERATION The PIM Pressure Independence Module is a modulating static pressure controller/actuator that allows
More informationMOTORIZED VOLUME DAMPER
MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers
More informationCircular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1
X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts
More informationLaboratory Solutions. pricecriticalcontrols.com
Laboratory Solutions pricecriticalcontrols.com Laboratory Solutions Laboratory Space Controller Native BACnet MS/TP (BTL Listed) High speed room level network Control multiple supply and general exhaust
More informationBACnet Lab and Pressurized Room Controllers with Off-board Air Modules
Technical Specification Sheet Document No. 149-855 November 04, 2015 BACnet Lab and Pressurized Room Controllers with Off-board Air Modules NOTE: The 570-8xxPA BACnet laboratory controllers have new 67xx
More informationSeries HCD Airfoil Control Damper
Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).
More informationACCESSORIES & OPTIONS FOR VENTURI AND VENTURI FX VALVES
FOR VENTURI AND VENTURI FX VALVES Price Belimo Actuator ACTUATORS Modulating variable volume valves are built with factory mounted Belimo actuators for both VAV and 2 Position flow control. Valves can
More informationSILENCER SELECTION INSTRUCTIONS
For general information in HVAC Acoustics, consult the following publications: 2013 ASHRAE Fundamentals Handbook, Chapter 8 Sound and Vibration 2011 ASHRAE Applications Handbook, Chapter 48 Noise and Vibration
More informationSINGLE DUCT TERMINAL UNITS 3000 SERIES
000 SERIES 000 SERIES VRIBLE OR CONSTNT VOLUME PRODUCT OVERVIE Nailor 000 Series Single Duct Terminal units are simply put, versatile. hether the requirement calls for a constant or variable air volume
More informationTVS/R FAN COIL UNITS HI-RISE, VERTICAL
TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE
More informationFOR USE IN SOLUTION AIR HANDLING UNITS
AMS-60 AIRFLOW MONITORING DEVICE APPLICATION GUIDE Supersedes: NOTHING Form 102.20-AG1 (303) FOR USE IN SOLUTION AIR HANDLING UNITS GENERAL The YORK AMS-60 is an airflow monitoring device which combines
More informationARROW INDUSTRIAL PRODUCTS
IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products
More informationVANEAXIAL & TUBEAXIAL FANS
BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications
More informationIntroduction to Johnson Controls Dampers
Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader
More informationRequires Ductwork and Blower
6' Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Requires Ductwork and
More informationProtector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector
Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Protector XStream Laboratory
More informationRAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL
RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model
More informationMANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.
MANUAL INSTALLATION Venturi FX VFX Series v100 Issue Date: 11/22/16 2016 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Safety Precautions... 1 Caution to Contractors...1
More information