Rooftop Ventilator. Noise level DB(A) Nominal speed RPM
|
|
- Allan Anthony
- 6 years ago
- Views:
Transcription
1 Rooftop Ventilator EMC APPROVED colours OPTIONAL Speed control Switch Internal ventilation valve Snow filter Part. No. Voltage V Air flow m 3 /h Watt W Nominal speed RPM Noise level DB(A) Function Suction/Blowing Rooftop opening mm Suction/Blowing 230 / ZW Suction/Blowing 230 / Suction/Blowing 230 / ZW Suction/Blowing 230 / without motor 230 / 245 Part. No. Material Roofring Material Cover ABS/White RAL 9010 PA6/White RAL ZW ABS/White RAL 9010 PA6/Black RAL ABS/White RAL 9010 PA6/White RAL ZW ABS/Black RAL 9005 PA6/Black RAL ABS/White RAL 9010 PA6/White RAL
2 Rooftop ventilator Le Mans EMC APPROVED colours OPTIONAL Speed control Switch Internal ventilation valve Snow filter Part. No. Voltage V Air flow m 3 /h Watt W Nominal speed RPM Noise level DB(A) Function Suction/Blowing Rooftop opening mm Suction/Blowing 230 / ZW Suction/Blowing 230 / Suction/Blowing 230 / ZW Suction/Blowing 230 / without motor 230 / 245 Part. No. Material Roofring Material Cover ABS/White RAL 9010 PA6/White RAL ZW ABS/White RAL 9010 PA6/Black RAL ABS/White RAL 9010 PA6/White RAL ZW ABS/Black RAL 9005 PA6/Black RAL ABS/White RAL 9010 PA6/White RAL
3 Rooftop Ventilator Le Mans LL brushless EMC APPROVED colour OPTIONAL Switch Internal ventilation valve Part. No. Remarks Voltage V Air flow m 3 /h Watt W Nominal speed RPM Noise level DB(A) Function Suction/Blowing Rooftop opening mm Suction With speedcontrol unit Suction Suction With speedcontrol unit Suction 230 Part. No. Remarks Material Roofring Material Cover ABS/Grey PA6/White Ral With speedcontrol unit ABS/Grey PA6/White Ral ABS/Grey PA6/White Ral With speedcontrol unit ABS/Grey PA6/White Ral A9
4 Rooftop Ventilator Ø Ø128 Roof cut out Turbo II turbo II REMARKS colours Standard mountingset suits roof thickness 1mm - 21mm (other mountingsets available on request) Part. No. Description Function Weight kg Bearing Material Remarks Rotating Exhaust Vent White Suction 1,2 2 Ball ABS Complete with Interior Grill & Shutter Rotating Exhaust Vent Black Suction 1,2 2 Ball ABS Complete with Interior Grill & Shutter 10
5 Rooftop Ventilator Air outlet Vehicle front Internal duct 50 Air inlet 14 Roof opening max. ± Exhaust ventilator colours Part. No. Function Suction/Blowing Weight kg Material Colour Suction 0,5 ABS White ZW Suction 0,5 ABS Black 11A11
6 Rooftop Ventilator Speed control The device has been developped adjust the rotation speed of a direct current motor (or the light capacity of an electric bulb), by means of the regulation of the voltage. The adjusting range is between 0 and 100% of the rotation speed (or light capacity). Min. input Voltage Max. input Voltage Max. continuous output current Max. output current Potentiometer Flat connectors Dim. housing l x w x h Height incl. connectors 11 VDC 30 VDC 25 A 30 A 4 k 7 6,3mm 80 x 60 x 20mm 30mm At zero position of the knob (potentiometer), the through the control absorbed current is 0A The unit s current limited, transient suppressed The housing is water proof 12
7 Rooftop Ventilator Switch Switch Part. No. Description way Switch on-off-on Part. No. Description way Switch on-off-on with ventilation symbols Red and Amber light 13A
8 Rooftop Ventilator Snow filter APPLICATION In rooftopventilators of vehicles, which are used in surroundings were it is possible that snow will be found in the air intake Part. No. Dimensions Description x 50 x 10mm For Rooftop ventilator /1006/1010/ x 40 x 10mm For Rooftop ventilator /0300, /2300, /0500, /
9 Rooftop Ventilator Floor vent 123 colour Part. No. Description Material Cut-out Dimension Floor Ventilator PC / ABS Ø129mm 15A
10 Internal Valve Flower power colours Part. No. Description Colour Voltage V LED Light Overall Diameter Material Internal Valve Flower Power White 280 ABS Internal Valve Flower Power Light Grey 280 ABS Internal Valve Flower Power Light Grey / Dark grey 280 ABS Internal Valve Flower Power with LED Light White White / 9 Blue LED s 280 ABS Internal Valve Flower Power with LED Light White White / 9 Blue LED s 280 ABS Internal Valve Flower Power with LED Light Light Grey White / 9 Blue LED s 280 ABS Internal Valve Flower Power with LED Light Light Grey White / 9 Blue LED s 280 ABS Internal Valve Flower Power with LED Light Light Grey / Dark grey White / 9 Blue LED s 280 ABS Internal Valve Flower Power with LED Light Light Grey / Dark grey White / 9 Blue LED s 280 ABS 17 17
11 Internal Valve OPTIONAL colours Micro-switch which switches off the ventilator when the valve is closed Part. No. Description Colour Overall Diameter Material Weight kg Internal Valve 300mm Grey 300 ABS 0, Internal Valve 300mm White 300 ABS 0, Internal Valve 300mm Black 300 ABS 0, Internal Valve 300mm with light 12V/24V White 300 ABS 0,7 18
12 Internal Valve V12 colours OPTIONAL Electrical Part. No. Description Remarks Colour Valve/Cover Colour Louver/Knob Overall Diameter Material Weight kg Internal Valve Manual White White 290 ABS 0, Internal Valve Manual Grey Grey 290 ABS 0, Internal Valve Manual Dark Grey Grey 290 ABS 0, Internal Valve Electric 12V/24V White White 290 ABS 0, Internal Valve Electric 12V/24V Grey Grey 290 ABS 0, Internal Valve Electric 12V/24V Dark Grey Grey 290 ABS 0,6 19A
13 Internal Valve Grill colours Part. No. Dimensions Material Colour Ø 270mm x 4mm ABS White Ø 270mm x 4mm ABS Light Grey Ø 270mm x 4mm ABS Black 20
14 Internal Valve Rotary ventilation valve colour Part. No. Construction Maximal Roof opening Plastic 160mm For / / A
15 Internal Valve Rotary ventilation valve colour Part. No. Construction Dimensions Light metal, polished Ø 130mm Light metal, polished Ø 160mm Light metal, polished Ø 180mm Light metal, polished Ø 200mm Light metal, polished Ø 250mm 22
16 Internal Valve Grill cover colours Part. No. Dimensions Material Colour Remarks Ø 140mm x 4mm ABS White For / / Ø 140mm x 4mm ABS Light Grey For / / Ø 140mm x 4mm ABS Black For / / * other colours available on request 23A
17 Manual 530 x 530 Roof Hatches 530 x 530 Electric 530 x 530 Glass Dome homologated ECE 43R Manual and Electric Homologated according EC 2004/104 Suits roof thickness 30mm-70mm Internal frame easy to mount in outside frame Pre-drilled mounting holes in outside frame 32
18 Roof Hatches Manual 970 x x 530 Emergency exit according EC2001/85 Manual and Electric Glass Dome homologated ECE 43R Homologated according EC 2004/104 Suits roof thickness 30mm-70mm Internal frame easy to mount in outside frame Pre-drilled mounting holes in outside frame With breakglass hammer Electric 970 x A
19 Roof Hatches Manual 530 x 530 REMARKS colour Glass Dome homologated ECE 43R Glass Dome homologated ECE 43R Suits roof thickness 30mm - 70mm High Quality Gaskets Internal frame easy to mount in outside frame Pre-drilled mounting holes in outside frame Part. No. Description Aperture Size Radius Glass DG-LUS Roof Hatch Manual Dark Glass 530 x R80 UV Transmission 6%, Heat Transmission 16%, Light Transmission 17% 35A
20 Roof Hatches Manual 970 x 530 colour REMARKS Emergency exit according EC2001/85 Glass Dome homologated ECE 43R Suits roof thickness 30mm - 70mm High Quality Gaskets Internal frame easy to mount in outside frame Pre-drilled mounting holes in outside frame With breakglass hammer Part. No. Description Aperture Size Radius Glass DG-LUS Roof Hatch Manual Dark Glass 970 x R80 UV Transmission 6%, Heat Transmission 16%, Light Transmission 17% 36
21 Roof Hatches ELECTRIC 530 x 530 EMC APPROVED colour REMARKS Glass Dome homologated ECE 43R Dark tinted glass Homologated according EC 2004/104 Suits roof thickness 30mm - 70mm High Quality Gaskets Internal frame easy to mount in outside frame Pre-drilled mounting holes in outside frame Part. No. Description Aperture Size Radius Glass E Roof Hatch Electric 24 Volt* 530 x R80 UV Transmission 6%, Heat Transmission 16%, Light Transmission 17% * For 12 Volt application, use our 12V to 24V Converter (89-STEP12-24) Use always our control unit in combination with the Electric Roof Hatch! 37A
22 Roof Hatches Electric 970 x 530 EMC APPROVED colour REMARKS Glass Dome homologated ECE 43R Emergency exit according EC2001/85 Glass Dome homologated ECE 43R Standard Dark tinted glass Homologated according EC 2004/104 Suits roof thickness 30mm - 70mm High Quality Gaskets Internal frame easy to mount in outside frame Pre-drilled mounting holes in outside frame With breakglass hammer Part. No. Description Aperture Size Radius Glass E Roof Hatch Electric 24 Volt* 970 x R80 UV Transmission 6%, Heat Transmission 16%, Light Transmission 17% * For 12 Volt application, use our 12V to 24V Converter (89-STEP12-24) Use always our control unit in combination with the Electric Roof Hatch! 38
23 Roof Hatches control unit EMC APPROVED colour REMARKS Homologated according EC 2004/104 The unit can control one or two electrical operated roof hatches To open/close front and backside of the roofhatch The position of the dome can be seen on the display (green Led s) The unit closes automatically when the ignition key is turned off Even when the ignition key is off, the hatch can be opened for ventilation The panel display has a current save function, reacting to usage Illumination with Orange Led s for the push buttons Part. No. Description Voltage V Outside Dimensions Control Unit 24 Volt for Electric Roofhatch 24* 96 x 49 x 28mm * For 12 Volt application, use our 12V to 24V Converter (89-STEP12-24) 39A
24
Heki 4 / 4plus Art. 1342
Heki 4 / 4plus 1/6 24.1 Content.DOC Heki 4 / 4plus Art. 1342 Content Ordering Details Technical Drawings Spare Parts Acrylic Dome Spare Parts Exterior Frame Spare Parts Interior Frame Dometic Seitz GmbH
More informationROOF FAN ROOFMASTER STEC
AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...
More informationPower consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3
SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage
More informationElectrical data Nominal voltage AC V / DC V Nominal voltage frequency
Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal
More informationVersion with operating bar
Midi-Heki 1/8 25.1 Content.DOC Midi-Heki Art. 1368 Art. 1369 Art. 1370 Content Version with operating bar Version with crank Elektrical version Ordering Details Technical Drawing Spare Parts Glazing Dome
More informationBrochure EX
Brochure 2012-2013.EX Maximum warmth, minimum dimensions The latest Jaga trench heating solution is only 6 cm high and 13 cm wide. With small, but powerful dynamic Low-h2o heat exchangers and super-quiet
More informationKnürr CoolBlast. Top-Mounting Fan for Miracel
Knürr Accessories Knürr Accessories Knürr CoolBlast Top-Mounting Fan Strong points Products Fan Top 1.109 1.110 1.113 Top-Mounting Fans 1.116 Knürr CoolBlast Fan Unit Strong points Products Accessories
More informationMSRP* 2007 Chevrolet Silverado 2500HD LS $42,400
Dark Pewter MSRP* 2007 Chevrolet Silverado 2500HD LS $42,400 1SK Package $825 16" x 6.5" Polished Aluminum (4) Models & Packages Exterior: Graystone Metallic $0 Interior: Dark Pewter w/custom Cloth Seat
More informationDESCRIPTION AND OPERATION
Page 1 of 10 DESCRIPTION AND OPERATION AIR DELIVERY DESCRIPTION AND OPERATION The air delivery description and operation is divided into five areas: HVAC Control Components Air Speed Air Delivery Recirculation
More informationGD 1000 series. Made for ADVANCE 1/99 FORM NUMBER
GD 000 series Parts list for model: GD 005-0-0V: 08700 GD 00-0-0V: 08800 GDS 00-0-0V: 08900 HDS 005-0-0V: 08600 Made for ADVANCE /99 FORM NUMBER 56045 TABLE OF CONTENTS SERVICE KIT GD 005, GD 00, GDS 00
More informationVENTILATION Opal Hatches Hatch Vent
Opal Hatches Onepiece aluminum lid with a thick frame section to provide optimum rigidity Slim, 3/4" (19mm) lid height Must be mounted on a flat surface CE approved areas: II, III, and IV Adjustable stay
More informationTerminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.
EuroSeries (ESR) Cowl & base moulded from recyclable polymeric material All sizes resistant to UV light Sizes 250 to 1000 dia are protected to IP54 Optional backdraught shutters and bird guard (250-630mm)
More informationBR80ARW - Stop / Tail / Indicator / Reverse 288. BR80ARR - Dual Stop / Tail / Indicator 288. BR80AR - Stop / Tail / Indicator 197
334 333 Led Lamps BR Series Polycarbonate Lens BR80ARW - Stop / Tail / Indicator / Reverse 288 ADR Approved. Built in reflex Reflector 107 Benefits: -High quality LED s (low power consumption) -Polycarbonate
More informationMODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN
MODEL FEATURES Exhaust air up to 2,630 CFM with static pressure capabilities to 1 w.g. Mixed flow impeller for excellent air flow to pressure performance ratio Direct connection, two-speed motor Ideal
More informationTA V TA V
TA-3030 12V TA-3031 24V High Cooling Capacity Low Power Consumption Small Dimensions Low Weight Parallel Flow Condenser Aluminum Body ABS Acrylic Cover TA-3030 12V p.n. 4500-030 TA-3031 24V p.n. 4500-031
More informationNCF fans 50 Hz. Protection class IP 55
The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.
More informationSpheros - Parabus Ltd. Roof Hatch Program. Hatches / Fans
Spheros - Parabus Ltd Roof Hatch Program Hatches / Fans 12/2016 Roof Hatch, manual and electrical emergency exit hatch Eleon Hatches / Fans Next Generation Modular Hatch Glass or plastic, manual or electric,
More informationPerformance. Sound Levels. Impellers. Motors. Accessories
EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class
More informationPneumatic Control Box Manual I630-E-01 1
Pneumatic Control Box Manual Pneumatic Control Box Manual I630-E-01 1 This Manual contains information of the Techman Robot product series (hereinafter referred to as the TM Robot).The information contained
More informationSilent centrifugal air heater hot water supply
Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises
More informationKnürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
More informationspare parts catalogue
spare parts catalogue Version 1.2013! IMPORTANT NOTICE! This engine is designed strictly for competition purposes only. The manufacturer SWISSAUTO declare that all spare parts and engines are not covered
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More informationElectronic Service Manuals
Electronic Service Manuals This electronic document is provided as a service to our customers. We do not create the contents of the information contained in this document. Should you have detailed questions
More informationLED Meteor Pool Lights
LE Pool Lights LE Pool Lights The ARTECTA pool lights are the world's first compact ultra-thin LE underwater fixtures, equipped with an integrated driver. The fixtures can be mounted on a flat surface,
More informationFresh air and exhaust air systems
Fresh air and exhaust air systems Fresh air and exhaust air systems Overview RECTANGULAR ROOF COWLS 1 2 3 4 5 6 7 Special versions on request 1 Jet cap DFH-E-Eco 5 Fresh air cowl ALH 2 Roof cowl DH 6 Discharge
More informationThe Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation
The is quiet even at high outputs, making it a discreet and effective heater for almost any situation A selection of grilles and finishes are available. Installation is simple and hassle-free due to the
More informationVEHICLE PARTS 215 AERIALS 216 HAND WASHES 217 HORNS 218 VENTILATION VEHICLE PARTS // PRODUCT FINDER
VEHICLE PARTS VEHICLE PARTS // PRODUCT FINDER 215 AERIALS 216 HAND WASHES 217 HORNS 218 VENTILATION We stock a select range of aerials for vehicles; hand washing systems to maintain roadside health and
More informationVORTICE VARIO I RANGE Flush mounted axial fans
Long Life 30.000 h VORTICE VARIO I RANGE Flush mounted axial fans Supply to improve the quality of air we breathe daily in any domestic or commercial environment: dwellings, shops & cafes, sports centers/gyms,
More informationApartment ventilation
GB1250 04.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box
More informationElectrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz
GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage
More informationMobile Diesel Heaters GRY-D / GRY-I Service Training Course
Mobile Diesel Heaters GRY-D / GRY-I Service Training Course 1 Rev. No. 3 January 24, 2011 GRY-I Indirect-fired Diesel Heaters GRY-I 15 WU GRYP 50 AP GRY-I 25 WU GRYP 90 AP GRY-I 40 WU GRYP 135 AP 2 GRY-D
More informationNCF fans 60Hz. Protection class IP 55
The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.
More informationClimate Control Products
Products Filter Fans NEMA 1 Box Fan High airflow with low noise operations makes these versatile packaged fans very popular in a wide range of applications. Reversible mounting brackets allow user to push
More informationMX-ventilation products
MX-ventilation products Technical brochure ENG Material Weatherproof and impact resistant polypropylene UV protected Solid coloured Reliable and controlled ventilation High-quality and durable materials
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey
More informationOil-free piston compressors KK and piston vacuum pumps KV
Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols
More informationMODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC
MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................
More informationGigaBox centrifugal fans Product specific information
GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,
More informationROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE
ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4
More informationCLIMA CANAL HYBRID HEATING AND COOLING CLIMA CANAL. Compact floor recessed fancoil unit HEATING
Compact floor recessed fancoil unit CLIMA CANAL HEATING AND COOLING: Build-in height of 3.94 > 5.71 CLIMA CANAL HEATING ONLY: Build-in height of 3.35 > 5.43 electronic control: 0...10V signal 24V EC motor
More informationVent-Axia Sabre Sickle Roof Fans (VSR)
Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,
More informationPractical examples of installation in the TD range
Practical examples of installation in the TD range The TD-MIXVENT system offers the most versatile installation range on the market, as a result of its multiple combinations; it can be used in a large
More informationApartment ventilation
GB1250 06.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box
More information2520- EC Motor Speed Controller
2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:
More informationSwitchmode rectifier type RKAS with PFC
Switchmode rectifier type RKAS with PFC RKA Power New technique sine wave input. New principle fully equipped. New technology easy to use. High rate charging fits with all type of stationary batteries.
More informationwell adjusted Round, wing and spindle-shaped knobs with the same standardised design and with matt surface.
104 combination knobs Order data on pages 194-199 well adjusted the product The name COMBINATION S stands for an exceedingly functional range of rotary buttons with a reliable collet fixture system. They
More informationLighting Symbols. Rotating LED LED light source with rotating reflector. LED. Rotating Halogen Halogen bulb light source with rotating reflector.
LED Technology Unrivalled lifespan of up to 100,000 hours together with low power consumption and resistance to high levels of shock and vibration make LEDs the ideal light source for emergency lighting.
More informationLED s. innovate! Catalogue 2010 Mast Products Int.
LED s innovate! Catalogue 2010 Mast Products Int. Retro Fit LED Light Units The new generation of LED Lights! Ready in just 2 steps 1 1 Choose your LED unit output Available in 3watt MR16 (50mm) & 60mm
More informationTHT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G
THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.
More informationAV series Anti-vandal and security pushbutton switches
Anti-vandal and security pushbutton switches Distinctive features Attractive, robust and durable Irremovable Anti-jamming construction : reduced travel to prevent insertion of foreign parts and mechanism
More informationMODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN
MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN MODEL FEATURES Exhaust air up to 2,630 CFM with static pressure capabilities to 1 w.g. Mixed flow impeller for excellent air flow to pressure performance ratio
More informationMAXIMA MOTORISED LOCKS
MAXIMA 95 96 MAXIMA MOTORISED LOCKS Motorised lock Mechanical opening with European type cylinder (cylinder with internal knob not usable) Striking plate in stainless steel (mm): 440 x 30 x 3 Armature
More informationLED safety Luminaries
LED safety Luminaries LED safety luminaire 5 years guarantee on LEDs INOTEC LED Safety luminaires high light output and variable SN 6204 LED SN 8141.1 LED SN 9024 LED Technical data SN 6101 LED SN 9141.1
More information6 MAINTENANCE AND WORKSHOP
EUROPEAN STANDARD SINCE 1963 6 MAINTENANCE AND WORKSHOP www.intertruck.com INDEX BALL JOINTS 329 COTTER PINS 330 CABLE TIES 331 TAPE 332 ASSORTMENT CASES 333 INSPECTION LIGHTS 334 TEST APPLIANCES 335 328
More informationDifferent mounting options by magnet, tube mounting or fix mounting Can be used as main beacon or as a third beacon
Operating manual COMET, STURN, NOV Control via CN447 or analogue \ Different sizes available Different mounting options by magnet, tube mounting or fix mounting Can be used as main beacon or as a third
More informationBroad multiplex outlet BF-V...
Air distribution systems Broad multiplex outlet BF-V... DS 40 E 04.0 Technical Selection Preliminary remarks In many applications in the commercial sector, supply air is discharged via simple grilles built
More informationTD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans
IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester
More informationSeries 1 Examination Lamp. Series 2 Examination- and Reading Lamp. Series 3 Reading Lamp. Series 4 Reading Lamp. Series 5 Examination Lamp
Lamps 23 Series 1 Examination Lamp LED, Halogen and Twin-Examination Lamp P. 26 Series 2 Examination- and Reading Lamp Small LED- and Halogen Examination-/Reading Lamp P. 34 Series 3 Reading Lamp Reading
More informationROLF-Window Art. 1333
ROLF-Window 1/8 42.1 Content.DOC ROLF-Window Art. 1333 Content Ordering Details Dimensions Technical Drawings ROLF Spare Parts Complete Components Spare Parts Exterior Frame Spare Parts Glazing Panel Spare
More informationTABLE OF CONTENTS SERVICE KIT DESCRIPTION
97-08 00-08 TABLE OF CONTENTS SERVICE KIT GM 200 - GM 300 - GM 400 & KING 500 SERIES, CONSUMER A 0.6.3 1 DESCRIPTION PLAN Motor, switches and cable reel A - 0.6.3-2 Main filters, dust bag A - 0.6.3-4 Wheel,
More informationData sheet. D-2011/05/ Date: 02/2013. Type TS50 CNG. Fuelling System. for installation in cars FUTURE. TECHNOLOGY. TODAY.
Data sheet D-2011/05/00160-3-3 Date: 02/2013 Type TS50 CNG Fuelling System for installation in cars FUTURE. TECHNOLOGY. TODAY. General Description Features Integrated WEH TN1 CNG receptacle (NGV1) with
More informationSkyView Art Content
Skyview 1/8 29.1 Content.DOC SkyView Art. 1388 Content Table of contents Ordering Details Technical Drawing Versions Spare Parts Glazing Panel spindle execution Spare Parts Glazing Panel lever execution
More informationDVAX-ARS. Roof-mounted unit for mechanical smoke extract
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans DVAX- Roof-mounted unit for mechanical smoke extract 2 DVAX DVAX- Roof-mounted axial fan unit
More informationSpindle drives. Spindle Drives SP
Spindle Drives SP Special Features sp For natural ventilation, smoke and heat exhausting systems Robust corrosion-resistant design Aluminium housing anodized finish with plastic end caps Easy installation
More informationPolar Trac Cab Groundsmaster 7200 Series Mower
Form No. 3408-250 Rev A Polar Trac Cab Groundsmaster 7200 Series Mower Model No. 30474 Serial No. 400000000 and Up Register at www.toro.com. Original Instructions (EN) *3408-250* A Ordering Replacement
More informationKrantz. Floor displacement outlet Q-B-DN 200. Air distribution systems
Krantz Floor displacement outlet Q-B-DN 0 Air distribution systems DS 62 E 05. Construction design Preliminary remarks Floor displacement outlets are usually used where wall or plinth displacement outlets
More informationRobLight FL User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:
99082127 06-08-2018 Rev. 4.0 User manual FL 1050 A/S Nordhavnsvej 1A DK - 9900 Frederikshavn Applies to: + 0132 0018 FL 1050 B-2 3000K CRI 90+ + 0132 0019 FL 1050 B-2 3000K CRI 95+ + 0132 0028 FL 1050
More informationTechnical Information. A U R O R A Konrad G. Schulz GmbH & Co. KG Tel.: /
1/8 Heater Mini Content: 1 Safety advises 2 Device description 3 Function description 4 Operation 5 Installation 6 Technical data 7 Maintenance 8 Spare parts 9 Optional accessories 10 Fault diagnosis A
More informationWGA Long throw nozzle grille
Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...
More informationGTi BODYSTYLE SAFETY SECURITY COMFORT AND CONVENIENCE. 3 door hatch
GTi BODYSTYLE 3 door hatch SAFETY 6 airbags ABS with Electronic Brake Force Distribution (EBFD) Emergency Brake Assist (EBA) Electronic Stability Program (ESP) Side impact absorbent door padding (front
More informationNCF 60 Hz. Protection class IP 55
The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.
More informationChapter 10: Valves for Pipe Mounting
Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure
More informationEuromas ABS / PC. Colour: Light grey, similar to RAL 7035; special colours on request
Euromas ABS / PC Detailed product information can be found on www.bopla.de - 36 sizes - 19 different M...V0 versions corresponding to UL 94 V0 - All M versions are listed under UL file no. 196 706 - Terminals
More informationChassis: VIN: DR43WERR4FEW34TR R Colour: Grey Seating: 5 Body Type: SUV, Five Door ESC / ESP: Yes. Interior
Page 1 of 8 Technical Centre: Auckland Mobile Inspections (0800 500 333, Option 1) Inspection Date: 9 Aug 2018 Mobile Inspection: Yes REPORT OWNER Inspection Report No.: Revision #1 on 09/08/2018 Name:
More informationSKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)
SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC) TABLE OF CONTENTS 1 EC Declaration of incorporation...1 2 General description...2
More informationRC8900XAB0,RC8900XAQ0
BURNER BOX PARTS 36" ELECTRIC DOWN DRAFT COOKTOP 8 93 Litho in U.S.A. 1 Part No. BURNER BOX PARTS 1 Top, Main 4321272 Black 4321271 White 2 786137 Shield, Switch 4 786222 Nut (2) 5 786211 Screw, Hold Down
More informationBRIZA Brochure UK 2013
BRIZA Brochure UK 2013 BRIZA Super slim and powerful heating, cooling and ventilation Briza is a climate unit with a dual personality: a Hybrid that provides comfortable heat in winter and refreshing cooling
More informationDC Dual Inlet Centrifugal Blowers
DC Dual Inlet Centrifugal Blowers 85 to 656 CFM Brushless DC Dual Inlet Centrifugal Blowers.5..9.6 4 6 8 35 3 5 5.3 3 5 3 4 5 6 Curve Ref. Rota- CFM Wgt. Temp. Number Part Number Volts Watts Flange tion*
More information2012 Isuzu Truck 16.1
16.1 NPR, NPR HD, NQR, NRR Diesel Electrical Symbols Symbol Meaning Symbol Meaning Symbol Meaning Fuse Electronic Parts Coil (Inductor), Solenoid Magnetic Valve Fusible Link Resistor Relay Fusible Link
More informationAvaLight-DHS Deuterium Halogen Light Source Operating manual
AvaLight-DHS Deuterium Halogen Light Source Operating manual Version 1.2 February 2006 14-02-06 AvaLight-DHS manual.doc 1 AvaLight-DHS Deuterium Halogen Light Source Safety Instructions Warning: All warnings
More informationEDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM
AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation
More informationLyteLaunch Dry - Wet and DMX Models. Operation Manual
LyteLaunch -150 Dry - Wet and DMX Models Operation Manual LyteLaunch 150 Introduction Thank you for purchasing the LyteLaunch 150 from Advanced Lighting Systems, Inc. This fiber optic lighting illuminator
More information2013 Isuzu Truck 16.1
2013 Isuzu Truck 16.1 NPR HD, NQR, NRR Diesel Electrical Symbols Symbol Meaning Symbol Meaning Symbol Meaning Fuse Electronic Parts Coil (Inductor), Solenoid Magnetic Valve Fusible Link Resistor Relay
More informationS4- / S4.6-Window Art = S4 Art = S4.6 *
S4-window 1/14 2.1 Content.DOC S4- / S4.6-Window Art. 1119 = S4 Art. 1319 = S4.6 * Content Ordering Details Dimensions Technical Drawings S4 Technical Drawings S4.6 Spare Parts Top Hung/Fixed S4-Window
More informationIN-LINE DUCT FANS MIXVENT-TD Fan Systems
IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment
More informationELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:
ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300 Part Number: 9 1210 00 106 Publication Number: 9 1210 00 993 Date: July, 1993 Revision F: July, 1996 WARNING To prevent personal injury or equipment damage,
More informationTable of contents. Small cases:
R Firmengruppe Table of contents Small cases: Small case x-dream 418......................... III 3 Small case Tarex 419............................ III 5 Small case Profi-case 415/416....................
More informationHIGH-POWERED VENTILATORS
HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series
More information2
Handling a complex world Installation and Operating Instructions Tachometer CAN Master Easy Link Gauge Installation and Operating Instructions 2 Contents Tachometer CAN Master Preliminary Remarks 4 Safety
More informationDPC6430. Documents DPC Tank and handle grips. 2 Hood, air filter. 3 Muffler, connecting muff. 4 Carburetor. 5 Starter assy., ignition assy.
Documents 1 Tank and handle grips 2 Hood, air filter 3 Muffler, connecting muff 4 Carburetor 5 Starter assy., ignition assy. 6 Cylinder, crankshaft, clutch 7 Cutting device, protection hood 8 Blades, tools
More informationVoltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]
Open condensing units with air condenser and semi-hermetic compressor Galvanized and painted in RAL7035 base Semi-hermetic compressor Air condenser unit with 4 poles fans 230/1 Vibration absorber on discharge
More informationACCESSORIES FOR DUCT FANS
FOR DUCT FANS Duct fan Clamp Filter box Silencer Electric heater Duct fans are mostly used in low-to medium-pressure ducted systems with additional components such as heaters, filter boxes, dampers, etc.
More informationCommon features. Installation options. Aesthetic options
New! LPI series Distinctive features and applications UG1006-A Common features Large ergonomic actuator (Ø 35 mm) Tactile feedback Low behind-panel depth (21 mm max.) Stylish design Long life This series
More informationDTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan
Product information - Version 3 DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Overskrift placering Table of contents Choice of motor... 4 DTV roof fans... 5 - Technical specifications
More informationData sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design
Data sheet Page: 1 / 5 Operating data Requested flow rate Operating data determined for maximum inlet pressure Requested developed head 15.00 m Pumped medium Ambient air temperature 20.0 C Fluid temperature
More information3.4 Wide Angle Nozzles
Product description Wide angle nozzles are ventilation end elements that are used for the distribution of inlet air at large distances. The flow direction of the inlet air is not only dependent on the
More informationElectrical data Nominal voltage AC 230 V Nominal voltage frequency
echnical data sheet NRA Rotary actuator for ball valves Nominal torque Nm Nominal voltage AC V Control Open-close, -point echnical data Electrical data Nominal voltage AC V Nominal voltage frequency 5/6
More informationNew for 2019 Bold represents changes from previous version Version 4
XC90 T5 250 hp, 258 lb. ft. torque, Direct-Injected Turbocharged Engine, 8-speed Geartronic Automatic with Start/Stop & Adaptive Shift Momentum R-Design SAFETY $47,200 $54,450 Oncoming Mitigation by Braking
More informationEngine, Gearbox. Performance. Safety. Electronics. Interior Equipment. Displacement (liters) Max. power (KW (HP)/rpm) Max. torque (Nm/rpm) Gearbox
SEAT Ateca. ATECA Engine, Gearbox Displacement (liters) Max. power (KW (HP)/rpm) Max. torque (Nm/rpm) Gearbox Performance Maximum speed (km/h) Acceleration 0-100 km/h (s) Combined fuel consumption (l/100
More information