DC Dual Inlet Centrifugal Blowers

Size: px
Start display at page:

Download "DC Dual Inlet Centrifugal Blowers"

Transcription

1 DC Dual Inlet Centrifugal Blowers

2 85 to 656 CFM Brushless DC Dual Inlet Centrifugal Blowers Curve Ref. Rota- CFM Wgt. Temp. Number Part Number Volts Watts Flange " dba (lbs.) Max. C D3G33-AB Yes R D3G33-DB No R DG33-DC No R NOTE: Wiring connection: Red = +; = ; Speed control by voltage typical range: +5% and 3%. *Rotation, as viewed from side opposite lead exit: R = clockwise; L = counter-clockwise Consult an application engineer for additional models and voltages for your specific needs, [ inches (mm)] Blower Type A B C D E F G H I J D3G33-AB (7) (8) (88) (79) (54) (38) (8) (74) (5) (69) D3G33-DB/C (4) (3) (97) (93) (3) ()

3 44 to 56 CFM Brushless DC Dual Inlet Centrifugal Blowers Curve Ref. Rota- CFM Wgt. Temp. Number Part Number Volts Watts Flange " dba (lbs.) Max. C D3G46-AA No R D3G46-AA Yes R D3G6-DA Yes L NOTE: Wiring connection: Red = +; = ; Speed control by voltage typical range: +5% and 3%. *Rotation, as viewed from side opposite lead exit: R = clockwise; L = counter-clockwise Consult an application engineer for additional models and voltages for your specific needs, [ inches (mm)] Blower Type A B C D E F G H I J D3G46-AA (5) (9) (96) (98) (3) (4) D3G46-AA (6) (9) (97) (98) (7) (54) (4) (6) (3) () D3G6-DA (6) (4) (7) (3) (4) (98) (45) (9) (76) (5)

4 DC Single Inlet Centrifugal Blowers

5 47 to 53 CFM Brushless DC Single Inlet Centrifugal Blowers Curve Part Number Ref. Rota- CFM Wgt. Temp. Number (Ball Bearings) Volts Watts Flange " dba (lbs.) Max. C GG85-AB4- Yes R GG85-AB- 4 3 Yes R GG97-AA6-9 7 No R GG97-AA6-4 8 No R GG97-AA No R NOTE: Wiring connection: Red = +; = ; Speed control by voltage typical range: +5% and 3%. *Rotation, as viewed from inlet side: R = clockwise; L = counter-clockwise Consult an application engineer for additional models and voltages for your specific needs, [ inches (mm)] Type A B C D E F G H I J K L M N O P Q GG85-AB M (7) (7) (6) (56) (76) (66) (68) (58) (56) (4) (6) (8) (5.5) (65) (84) (3) GG97-AA n/a n/a n/a n/a M4 n/a (43) (37) (75) (6) (4) (46) (4) (4) (8) (96) (45)

6 3 to 3 CFM Brushless DC Single Inlet Centrifugal Blowers Curve Part Number Ref. Rota- CFM Wgt. Temp. Number (Ball Bearings) Volts Watts Flange " dba (lbs.) Max. C GG-AR3-4 Yes R GG-AR Yes R G3G46-BF Yes L NOTE: Wiring connection: Red = +; = ; Speed control by voltage typical range: +5% and 3%. *Rotation, as viewed from inlet side: R = clockwise; L = counter-clockwise Consult an application engineer for additional models and voltages for your specific needs, [ inches (mm)] Type A B C D E F G H I J K L M N O P Q GG-AR M (74) (9) (8) (8) (5) () (83) (68) (76) (5) (8) (98) (7) () (3) (45) G3G46-BF M (6) (6) (3)(7)(3) (5) () (5) (94) (9) () (3) (6) (5) (58) (45)

7 Centrifugal Blowers User benefits include: Excellent air flows at higher output pressures Extremely stable pressure / volume characteristics High efficiency with either brushless DC or AC shaded-pole motors Low noise levels Typical applications include: Induced draft blowers for heating equipment Inlet blowers for heating equipment where additional outside air is required Air conditioner blowers Dishwasher dryer blowers Cabinet and enclosure cooling Ventilation for fume hoods in cooking and processing applications Blowers for portable and storage heaters Specialized ventilation, extraction and exhaust applications INDUSTRIES, INC. Tel: Fax sales@ebm.com Hyde Road, Farmington, CT 634 Internet:

8 Centrifugal Blowers SINGLE and DUAL INLET CENTRIFUGAL BLOWERS with a variety of impeller diameters, impeller widths and discharge openings, and motor positions to meet user needs and air moving requirements. Available with 5 or 3 volt AC shaded-pole motors, or with or 4 volt brushless DC motors. Here s a compact, versatile answer when you need spot cooling, forced air input, or air movement against higher back pressures. Discuss your needs with one of our application engineers at INDUSTRIES, INC. Tel: Fax sales@ebm.com Hyde Road, Farmington, CT 634 Internet:

9 SINGLE INLET BLOWERS CFM Max. S.P. Insul. MODEL Series ) (in H O) Volts Hertz Watts Class Position.8 (46) 3.43 (87) RL59/ B Left RL59/ B Right. (3).56 (65). (8).8 (58) 3.3 (8) CFM Max. S.P. Insul. MODEL Series (@ ) (in H O) Volts Hertz Watts Class Position 5.35 (36) RL76/ B Left RL76/4 Right RL76/ B Left RL76/86 Right.3 (54) 5.6 (8) max.97 (5) 5.8 (3.5) CFM Max. S.P. Insul. MODEL Series (@ ) (in H O) Volts Hertz Watts Class Position RL85/ B Left RL85/4 Right RL85/ B Left RL85/86 Right 4.5 (8) 7.8 (85) max 5.35 (36).97 (5) 5.8 (3.5) CFM Max. S.P. Insul. MODEL Series (@ ) (in H O) Volts Hertz Watts Class Position 6.69 (7) RL97/ B Left RL97/4 Right RL97/ B Left RL97/86 Right 6.4 (6.5) 3.7 (78) 3.8 (97).44 (6) 5.74 (46) Max..36 (6) CFM Max. S.P. Insul. MODEL Series (@ ) (in H O) Volts Hertz Watts Class Position 6.69 (7) RL8/ B Left RL8/4 Right CFM Max. S.P. Insul. MODEL Series (@ ) (in H O) Volts Hertz Watts Class Position RL46/ B Left RL46/6 Right DUAL INLET BLOWER CFM Max. S.P. Insul. MODEL Series (@ ) (in H O) Volts Hertz Watts Class Position 7. (78) 3.37 (86) 5.74 (46) 6.4 (6.5) 3.7 (78). (57) max 3.8 (97). (54) max 9.9 (36) 5.3 (35) 6.69 (7) 4.4 () 8.3 (4) Max. 8.7 ().36 (6) RL97/ B Right.5 (63.5) 3.8 (97) TWIN BLOWERS CFM Max. S.P. Insul. MODEL Series (@ ) (in H O) Volts Hertz Watts Class Position RLF67/7676A-33LH-486AFU H Center RL97/ B Center 4.3 (9.5).44 (6).48 (37.5) 3.8 (97).77 (45) 3.54 (9) 4.45 (3) 6.4 (6.5).48 (66) INDUSTRIES, INC. Tel: Fax sales@ebm.com Hyde Road, Farmington, CT 634 Internet:

10 AC Dual Inlet Centrifugal Blowers

11 to 75 CFM, 5 & 3 Volt AC Dual Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) DE97-CB-3 5 5/6 43 Yes L A 5 DE97-CB- 3 5/6 4 Yes L A.5 DE97-CB No L A 5 DE97-CB- 3 5/6 4 No L A.5 DE97-BE Yes L A 6 DE97-BE /6 54 Yes L A **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise inches & (millimeters) Type A B C D E F G H I J DE97-CB (44) (37) (76) (6) (4) (8) (78) (66) (8) (46) Wiring Diagram A. PSC "Type E" Permanent Split Capacitor "E" Black Run Capacitor (External) Line Voltage DE97-BE (6) (65) (86) (68) (8) (68) () (88) (46) (67) Green/Yellow Ground (optional) An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements

12 8 to 46 CFM, 5 & 3 Volt AC Dual Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) DE33-BE Yes L A DE33-BE Yes L A D4E33-AA-5 3 5/6 7 Yes R A D4E33-AA- 3 5/6 7 No R A 3 DE33-AB Yes R A 6 3 DE33-AM /6 9 Yes R A 3 3 DE33-AB No R A 6 3 DE33-AM47-3 5/6 9 No R A 3 4 DE33-DB Yes R A 6 4 DE33-DM /6 95 Yes R A 3 4 DE33-DB No L A 6 4 DE33-DM47-3 5/6 95 No R A 3 5 D4E33-DB Yes R A 7 5 D4E33-DB-5 3 5/6 95 Yes R A 5 D4E33-DB No R A 7 5 D4E33-DB- 3 5/6 95 No R A **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise inches & (millimeters) Type A B C D E F G H I J DE33-BE (7) (8) (88) (8) (94) (78) (8) (9) (55) (69) D4E33-AA (7) (8) (88) (76) (54) (38) (8) (9) (5) (69) DE AB & AM (7) (8) (88) (76) (54) (38) (8) (9) (5) (69) DE DB & DM (4) (3) (97) (98) (7) (54) (4) (6) (3) () D4E33-DB (4) (3) (97) (98) (7) (54) (4) (6) (3) ()

13 47 to 8 CFM, 5 & 3 Volt AC Dual Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) D4E46-AA Yes L A 8 D4E46-AA7-3 5/6 6 Yes L A D4E8-BA Yes L A 3 D4E8-BA- 3 5/6 46 Yes L A **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise Wiring Diagram inches & (millimeters) Type A B C D E F G H I J D4E46-AA (6) (9) (97) (98) (7) (54) (4) (6) (3) () A. PSC "Type E" Permanent Split Capacitor "E" Black Run Capacitor (External) Line Voltage D4E8-BA (96) (33) (33) (36) (39) (87) (88) (68) (55) (34) Green/Yellow Ground (optional) An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements

14 5 to 6 CFM, 5 & 3 Volt AC Dual Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) RDS-4/474A 5 5/6 4 No R 5 n/a 4 C RDS-4/6 3 5/6 4 No R 5 n/a 4 C 3 RDS-4/ No R 75 n/a 4 8 C 35 RDS-4/ No R 75 n/a 4 8 C 8 3 RDS-4/ No R 6 n/a 4 33 C 4 3 RDS-4/ No R 6 n/a 4 33 C **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise inches & (millimeters) Type A B C D E F G H I J RDS-4/474A & n/a n/a n/a n/a.5 5. (34) (345) (4) (48) (9) (7) RDS-4/66 & n/a n/a n/a n/a.5 5. (34) (345) (4) (48) (9) (7) RDS-4/37 & n/a n/a n/a n/a (34) (345) (4) (48) (378) (7) Wiring Diagram C. PSC Line Voltage T k (T.O.P.) T k (T.O.P.) U Z Z Capacitor U Permanent Split Capacitor Green/ Yellow An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements T k leads are brown. U & U leads are blue. Z & Z eads are black. Dotted lines not supplied on all design.

15 to 8 CFM, 5 & 3 Volt AC Dual Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) RD5S-4/96* 5 5/6 5 No R * n/a 4 4 C 6 RD5S-4/3* 3 5/6 No R * n/a 4 4 C 4 3 RD5S-4/698* 5 5/6 8 No R 8* n/a 4 44 C 9 3 RD5S-4/978* 3 5/6 8 No R 8* n/a 4 44 C RD8S-6/678* No R 35* n/a 4 54 C * Not to be run wide open - refer to performance curve. **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise Wiring Diagram inches & (millimeters) Type A B C D E F G H I J RD5S-4/96 & n/a n/a n/a n/a (44) (448) (79) (9) (9) (68) RD5S-4/698 & n/a n/a n/a n/a (44) (448) (79) (9) (378) (68) RD8S-6/ n/a n/a n/a n/a (47) (53) (7) (3) (378) (96) C. PSC Line Voltage T k (T.O.P.) T k (T.O.P.) U Z Z Capacitor U Permanent Split Capacitor Green/ Yellow An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements T k leads are brown. U & U leads are blue. Z & Z leads are black. Dotted lines not supplied on all design. FOR RD8S: Tk leadsare white. U & U leads are blue. Z & Z leads are brown. Ground is green/yellow

16 53 to 65 CFM, Three Phase AC Dual Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Number NUMBER Volts Watts Flange " dba Max C (lbs.) RD3P-4/733* 44 3Ø No R 53* n/a 4 4 RD35P-4/7334* 44 3Ø 98 No R 65* n/a 4 44 * Not to be run wide open - refer to performance curve. **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise inches & (millimeters) Type A B C D E F G H I J RD3P-4/ n/a n/a n/a n/a 5.94 n/a (56) (63) () (58) (45) RD35P-4/ n/a n/a n/a n/a 7.87 n/a (576) (674) (6) (74) (454)

17 AC Single Inlet Centrifugal Blowers

18 37 to 56 CFM, 5 & 3 Volt AC Single Inlet Centrifugal Blowers Curve Rota- CFM Temp. Wgt. Wiring Capacitor Number Part Number Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) GS85-AA /6 Yes R B - GS85-AA3-3 5/6 Yes R B - GE85-AA Yes R A 4 GE85-AA-5 3 5/6 8 Yes R A 3 GS97-DB /6 3 No R B - 3 GS97-DB3-3 5/6 3 No R B - **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise Wiring Diagrams A. PSC "Type E" Permanent Split Capacitor "E" Black Green/Yellow Ground (optional) Run Capacitor (External) Line Voltage An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements B. Shaded Pole Shaded Pole "S" Line Voltage Green/Yellow Ground (optional) inches & (millimeters) Type Notes A B C D E F G H I J K L M N O P Q GS85-AA M4* (7) (7) (6) (56) (76) (66) (68) (58) (56) (4) (6) (8) (5.5) (65) (84) (3) GE85-AA M4* (8) (7) (6) (56) (76) (66) (68) (58) (56) (4) (6) (8) (5.5) (65) (84) (3) GS97-DB N/A n/a (43) (37) (75) (6) (4) (46) (4) (4) (8) (96) (3) NOTE : Sheet metal housing. 85 models have cast aluminum housings * Tapped hole in aluminum housing

19 9 to 6 CFM, 5 & 3 Volt AC Single Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) GE8-AA Yes R A 4 GE8-AA Yes R A.5 GE-CA No R A 8 GE-CR- 3 5/6 Yes R A 3 GE-AR Yes R A 6 3 GE-AR Yes R A 4 GE33-DN No R A 8 4 GE33-DN /6 88 No R A *Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise Wiring Diagram A. PSC "Type E" Permanent Split Capacitor "E" Black Run Capacitor (External) Line Voltage Green/Yellow Ground (optional) An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements inches & (millimeters) Type Notes A B C D E F G H I J K L M N O P Q GE8-AA M4* (59) (83) (79) (7) (5) (97) (83) (66) (76) (5) (8) (8) (8) (87) (8) (3) GE-AR M4* (74) (9) (8) (8) (5) () (83) (68) (76) (5) (8) (98) (7) () (3) (45) GE-CA/CR (7) (7) (87) (79) () (94) (98) (8) (77) (67) (77) (99) (3) (6) (96) () (45) GE33-DN (7) (8) (87) (79) (59) (67) (59) (8) (3) (6) - (4) (45) NOTE : Sheet metal housing. Other models have cast aluminum housings * Tapped hole in aluminum housing

20 8 to 38 CFM, 5 & 3 Volt AC Single Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) GE4-AL Yes R 8* A GE4-AL /6 45 Yes R 8* A GE4-AC Yes R A 6 GE4-AC Yes R A 4 3 GE46-BF5-9* Yes R 38* A 3 GE46-BF-35* Yes R 38* A 5 * Not to be run wide open - refer to performance curve. **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise Wiring Diagram A. PSC "Type E" Permanent Split Capacitor "E" Black Run Capacitor (External) Line Voltage Green/Yellow Ground (optional) An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements inches & (millimeters) Type Notes A B C D E F G H I J K L M* N O P Q GE4-AL M (6) (6) (3) (7) (3) (5) () (5) (94) (9) () () (6.6)(8) (58) (45) GE4-AC M (6) (6) (3) (7) (3) (5) () (5) (94) (9) () () (6.6)(8) (58) (45) GE46-BF M (6) (6) (3) (7) (3) (5) () (5) (94) (9) () (4) (6.3)(6) (58) (45) NOTE : Sheet metal housing available on special order, standard housing cast aluminum * Tapped hole in aluminum housing

21 6 to 35 CFM, 5 & 3 Volt AC Single Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) G4E6-AB Yes R A 7 G4E6-AB- 3 5/6 65 Yes R A G4E8-AB Yes R A G4E8-AB Yes R A 3 * Not to be run wide open - refer to performance curve. **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise Wiring Diagram A. PSC "Type E" Permanent Split Capacitor "E" Black Run Capacitor (External) Line Voltage Green/Yellow Ground (optional) An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements inches & (millimeters) Type Notes A B C D E F G H I J K L M* N O P Q G4E6-AB M (6) (6) (3) (7) (3) (5) () (5) (94) (9) () () (6.6)(3) (75) (45) G4E8-AB M (6) (93) () () (5) () (4) () (86) () (9) (5) (7) (5) (94) (45) Notes:. Sheet metal housing available on special order, cast aluminum is standard *Tapped hole in aluminum housing. 75

22 7 to 8 CFM, 5 & 3 Volt AC Single Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) RGP-4/ Yes R 7* 83 4 C 6 RGP-4/ Yes R 7* 83 4 C 4 RGP-4/ Yes R 8* C 5 RGP-4/ Yes R 8* C 6 * Not to be run wide open - refer to performance curve. **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise Wiring Diagram C. PSC Line Voltage T k (T.O.P.) T k (T.O.P.) U Z Z Permanent Split Capacitor Capacitor U Green/ Yellow An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements T k leads are brown. U & U leads are blue. Z & Z eads are black. Dotted lines not supplied on all design. inches & (millimeters) Type Notes A B C D E F G H I J K L M N O P Q RGP M (34) (44) (64) (8) (8) (6) (36) (86) (9) (53) (9) () () (45) RGP M (38) (473) (8) (97) () (76) (348) (36) (44) (83) (44) (4) () (45) NOTE : Sheet metal housing

23 to 5 CFM, 5 & 3 Volt AC Single Inlet Centrifugal Blowers Curve PART Rota- CFM Temp. Wgt. Wiring Capacitor Number NUMBER Volts Hertz Watts Flange " dba Max C (lbs.) Dgm# (µf) RG5P-4/ Yes R 5* C 6 RG5P-4/ Yes R 5* C 6 RG8P-4/ Yes R * C 5 * Not to be run wide open - refer to performance curve. **Rotation as viewed from side opposite the lead exit: R = clockwise; L = counter-clockwise Wiring Diagram C. PSC Line Voltage T k (T.O.P.) T k (T.O.P.) U Z Z Permanent Split Capacitor Capacitor U Green/ Yellow An extra capacitor can be connected in series to yield lower RPM for multi-speed requirements T k leads are brown. U & U leads are blue. Z & Z eads are black. Dotted lines not supplied on all design. inches & (millimeters) Type Notes A B C D E F G H I J K L M N O P Q RG5P M (47) (486) (95) () () (76) (38) (36) (64) (38) (64) (65) () (45) RG8P M (463) (58) (5) () (43) (76) (4) (36) (84) (358) (84) (9) () (45) NOTE : Sheet metal housing

Hammond Electronic Rack Packaging

Hammond Electronic Rack Packaging Hammond Electronic Rack Packaging 195 1 4-20 spring loaded nuts and 0.62 round head slotted bolts and washers for C channels. Description Net Price l 1421S Pkg. of 4 $14.82 CABLE ORGANIZING RING PANELS

More information

Rotron NANOS Small Vaneaxial Fans

Rotron NANOS Small Vaneaxial Fans Rotron NANOS Small Vaneaxial Fans Nanos Small Vaneaxial Information Nanos Small Vaneaxial Fans are compact, high-speed fans with axial airflow. The impeller and guide vanes are of airfoil configuration

More information

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans. 4 AC Fans AC Fans Overview 7 AC Axial Fans 8 AC Radial Fans 38 AC Radial Fans AC Axial Fans AC Fans ACmaxx Axial Fans Technology DC Axial Fans Specials DC Radial Fans 5 Accessories AC Fans Technical Informations

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning In-Line centrifugal electric pumps with stainless steel hydraulic parts AISI 304. APPLICATIONS Civil/industrial heating plants Systems for moving domestic hot water Cooling and air conditioning plants

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

Energy-saving axial fans. A solution specifically designed for unit cooler applications. The engineer s choice. 10-Position rotary switch

Energy-saving axial fans. A solution specifically designed for unit cooler applications. The engineer s choice. 10-Position rotary switch Energy-saving axial fans A solution specifically designed for unit cooler applications. The engineer s choice 0-Position rotary switch New SG05 series designed for unit cooler applications EC axial fans

More information

Rotron MAXIAX 5.75 Large Vaneaxial Fans

Rotron MAXIAX 5.75 Large Vaneaxial Fans Rotron MAXIAX 5.75 Large Vaneaxial Fans General Large Vaneaxial Information MAXIAX fans provide relatively high flows against high impedance in a compact axial flow package. They operate at high rotational

More information

AVC FAN. AC Axial Fans. AC Axial Fans

AVC FAN. AC Axial Fans. AC Axial Fans AC Axial Fans AC Axial Fans 63 AS SERIES 80*80*38 mm Motor:Shaded pole AC motor. Frame & Imeller:Al Die-casting & PBT plastic. AS8038-V1H-_ B S 110 50/60 14/11 AS8038-V2H-_ B S 230 50/60 14/11 2450/2950

More information

Rotron HF/ HFV/ HFG Propeller Fans

Rotron HF/ HFV/ HFG Propeller Fans Rotron HF/ HFV/ HFG Propeller Fans General Propeller Information Propeller Fans have sheet metal blades, usually four or more in number, which are curved to provide an aerodynamic lift and are generally

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial

More information

Rotron MAXIAX Large Vaneaxial Fans

Rotron MAXIAX Large Vaneaxial Fans Rotron MAXIAX 3.-3.75 Large Vaneaxial Fans General Large Vaneaxial Information MAXIAX fans provide relatively high flows against high impedance in a compact axial flow package. They operate at high rotational

More information

SV-UNOBOX FAN. Mutassim Al-Daour factory for Metal Industries SV-7

SV-UNOBOX FAN. Mutassim Al-Daour factory for Metal Industries SV-7 SV-UNOBOX FAN Mutassim Al-Daour factory for Metal Industries SV-7 INDEX INTRODUCTION PERFORMANCE GRAPHS TECHNICAL DATA DIMENSIONS ACOUSTIC DATA - SOUND PRESSURE LEVEL ELECTRICAL DETAILS pages - - 7 8 9

More information

Air Moving Products & Accessories. air Catalog. featuring...gates Belts FAN BLADES BLOWER WHEELS ACCESSORIES V-BELTS ADAPTER HEX HUBS ETC.

Air Moving Products & Accessories. air Catalog. featuring...gates Belts FAN BLADES BLOWER WHEELS ACCESSORIES V-BELTS ADAPTER HEX HUBS ETC. air Air Moving Products & Accessories 2006 Catalog featuring...gates Belts FAN BLADES BLOWER WHEELS ACCESSORIES V-BELTS ADAPTER HEX HUBS ETC. IR MARS AIR MOVING COMPONENTS AIR MOVING COMPONENTS AN BLADES

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial and

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

PELLET HEATING SYSTEM MOTOR

PELLET HEATING SYSTEM MOTOR www.spg.co.kr PELLET HEATING SYSTEM MOTOR 21C Standard of The World Geared Motor What is their choice? It is SPG All of the four major electric home appliance manufacturers ; GE, Whirlpool, Electrolux,

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES TABLE OF CONTENTS Motor Information Guide Definitions And Abbreviations... page 2 Motor Identification Without A Nameplate What To Look For... page 3 Direct Drive Blower Motors: Two Speed... page 4 Three

More information

IEC Metric Motors DC Metric Motors Metric (IEC) Frame - SCR Rated - IP54

IEC Metric Motors DC Metric Motors Metric (IEC) Frame - SCR Rated - IP54 Motors Motors Gearmotors Metric Motors Metric Motors Metric () - SCR Rated - IP54 Application Notes: Please note that one or more of the mounting kits must be used with motors of these frame sizes. See

More information

Your Clean Air Source!

Your Clean Air Source! Forward Curve Your Clean Air Source! HIGH QUALITY... HIGH EFFICIENCY... VERSATILITY Established in 1893, Peerless Blowers has a well established record of manufacturing a complete line of heavyduty industrial

More information

WALL & STAND FANS CATALOG

WALL & STAND FANS CATALOG WALL & STAND FANS CATALOG 18 SEMI-INDUSTRIAL WALL AND STAND FANS Ideal for gyms, auditoriums, schools, churches and industrial spaces that need powerful air circulation PRODUCT INFORMATION Motor 3-speed,

More information

TORIN by: AIRDEX Index Page No.

TORIN by: AIRDEX Index Page No. Index Page No. N Series Fans 2 Bladed, Heavy Duty...1 N Series Fans 3 Bladed, Free Air...2-3 N Series Fans 4 Bladed, Heavy Duty...4-5 Universal Hubs...6 One Piece Fan O Series 4 & 5 Bladed...7 One Piece

More information

Basic Hydraulic Features. Basic Mechanical Features

Basic Hydraulic Features. Basic Mechanical Features APRIL 2006 1.0 Overview The ETA is designed for flow rates that fall beyond the range of most end suction pumps. Performance extends to 9,500 GPM, 440 feet of head, and 88% efficiency. This range is covered

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS: WOB-L PISTON Pumps and Compressors 607/668/669/688/689 Series MODELS: Standard models available. 607CA22, 607CA32, 607CD22, 607CD32 668CE44, 668CGHI44 688CE44, 688CGHI44 669CE44, 669CHGI44 689CE44, 689CGHI44

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Single-inlet centrifugal fans

Single-inlet centrifugal fans CE 200-280 4-pole Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable CE fans are easy to install. Fans in this series have impellers with forward-curved

More information

Cabinet Fans & Smoke Spill Cabinet Fans

Cabinet Fans & Smoke Spill Cabinet Fans 1 Cabinet s & Smoke Spill Cabinet s Direct Drive Cabinet Single Skin - CD Series Cabinet manufactured in galvanized steel complete with inlet & outlet spigots. Squirrel cage induction motors with sealed

More information

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced. LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a

More information

TEC2010 SERIES SINGLE SCROLL DC MOTORS BH4400 / BH1700 / BH1900 DC MOTORS. DCM manufacturing, inc. 153

TEC2010 SERIES SINGLE SCROLL DC MOTORS BH4400 / BH1700 / BH1900 DC MOTORS.  DCM manufacturing, inc. 153 TEC21 SERIES SINGLE SCROLL BH44 / BH17 / BH19 www.dcm-mfg.com DCM manufacturing, inc. 153 MOTOR SELECTION CRITERIA 3 DIAMETER MOTOR SELECTION CRITERIA MOUNTING: 3 in. Diameter Can style motors are available

More information

INVITATION TO BID. (This is not an order.)

INVITATION TO BID. (This is not an order.) Page 1 of 6 SCHEDULE OF EVENTS Event Description 1 / 1 ARMSTRONG CIRCULATING PUMP 3.00000 / Event Date ARMSTRONG #H51-1 BF CIRCULATING PUMP------------- TECHNICAL SPECS--- Item Hot Water Circulating Pump

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN MODEL FEATURES Exhaust air up to 2,630 CFM with static pressure capabilities to 1 w.g. Mixed flow impeller for excellent air flow to pressure performance ratio Direct connection, two-speed motor Ideal

More information

Energy-saving motors (ESM)

Energy-saving motors (ESM) Energy-saving motors (ESM) Technology Accessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans A series fans Energy-saving motors (ESM) 316 Air performance curves 3 Energy-saving

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

ABANICOS C. DURAN LOS FLAMBOYANES SHOPPING CENTER 65 TH INFANTERIA AVE. #5 SAN JUAN, PR TEL: ,

ABANICOS C. DURAN LOS FLAMBOYANES SHOPPING CENTER 65 TH INFANTERIA AVE. #5 SAN JUAN, PR TEL: , ABANICOS C. DURAN LOS FLAMBOYANES SHOPPING CENTER 65 TH INFANTERIA AVE. #5 SAN JUAN, PR 00923 TEL: 787-765-3957, 787-771-9798 EMAIL: WWW.ABANICOSCDURAN@HOTMAIL.COM, ABANICOCDURAN@HOTMAIL.COM Ideal for

More information

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated

More information

RADIAL ALUMINUM LOW PRESSURE

RADIAL ALUMINUM LOW PRESSURE RADIAL ALUMINUM LOW PRESSURE Content LOW PRESSURE BLOWERS... 2 GENERAL... 3 D03M, E03... 4 D04M, E04... 5 D045M, E045... 6 D05M, E05... 7 D052M, E052... 8 D060, E060... 9 D064, E064... 10 D066, E066...

More information

FloCheck is a precision engineered, twin plate check valve suitable for product or service lines, wherever non-return protection is required.

FloCheck is a precision engineered, twin plate check valve suitable for product or service lines, wherever non-return protection is required. FloCheck is a precision engineered, twin plate check valve suitable for product or service lines, wherever non-return protection is required. Features Twin plate, flat seat design for enhanced sealing.

More information

It is SPG. 21C Standard of The World Geared Motor. Product descriptions

It is SPG. 21C Standard of The World Geared Motor. Product descriptions 21C Standard of The World Geared Motor It isspg All of the four major electric home appliance manufacturers ; GE, Whirlpool, Electrolux, have chosen SPG Motor. SPG which produces the world best quality

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

MONOBLOC CENTRIFUGAL ELECTRIC PUMP IN COMPLIANCE WITH EN 733 in cast iron

MONOBLOC CENTRIFUGAL ELECTRIC PUMP IN COMPLIANCE WITH EN 733 in cast iron Cast iron monobloc centrifugal electric pumps in compliance with EN 733. APPLICATIONS Moving clean water for civil, agricultural, industrial use, pressure boosting units, heating and air conditioning plants

More information

42HS Fan Coil Unit (High Static Pressure)

42HS Fan Coil Unit (High Static Pressure) 42S Fan Coil Unit (igh Static Pressure) Air Volume: 1360~3400m3/h Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL AND BEARINGS 302 MECHANICAL SEAL 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL AND BEARINGS 302 MECHANICAL SEAL 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE A (UP TO 0.6 KW) 204 PERFORMANCE CURVE A (FROM 0.75 KW UP TO 1.1 KW)

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to

More information

Square Inline Fans with Multi-Directional Discharge

Square Inline Fans with Multi-Directional Discharge SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to

More information

Center Mount Unit Coolers

Center Mount Unit Coolers LK-CMTB JAN 2018 Replaces LK-CMTB JULY 2017 Center Mount Unit Coolers Technical Guide s ACM Air Defrost ECM Electric Defrost Table of Contents Nomenclature 2 Features & Benefits 3 Performance Data 4 Specifications

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

2CDU70/206-2HP 2CDU70/306-3HP CDU120/306-3HP 2CDU200/506-5HP 607

2CDU70/206-2HP 2CDU70/306-3HP CDU120/306-3HP 2CDU200/506-5HP 607 Model CDX/CDU Contents CDX/CDU Item No. Specifications Selection Performance Pump Sectional Motor Chart Curve Dimensions View Data CDXU70/06-HP CDXU70/6-HP 5 6 8 6 CDXU0/6-HP CDXU00/6-5HP 7 CDU70/06-HP

More information

TG6 series cross flow fan units

TG6 series cross flow fan units TG6 series General ross flow fan units have become increasingly widely used due to theris compact size, low noise and reliable operation. The rotating blower creates an internal vortex which directs the

More information

Motor Basics AGSM 325 Motors vs Engines

Motor Basics AGSM 325 Motors vs Engines Motor Basics AGSM 325 Motors vs Engines Motors convert electrical energy to mechanical energy. Engines convert chemical energy to mechanical energy. 1 Motors Advantages Low Initial Cost - $/Hp Simple &

More information

VERTICAL MULTI-STAGE PUMPS

VERTICAL MULTI-STAGE PUMPS VR SERIES - 6 HZ FEATURES All 316 stainless steel hydraulic components for superior durability, efficiency, and performance over a wide variety of applications Rugged NEMA motor mounting with oversized

More information

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial Vertical multistage centrifugal electric pumps available in various versions: cast iron (G), AISI 304 stainless steel (), AISI 316 stainless steel (L). APPLICATIONS Civil, industrial, agricultural and

More information

The Replacement Motor & Fan Specialists

The Replacement Motor & Fan Specialists The Replacement Motor & Fan Specialists Residential Commercial Electric Motors Fans & Blowers Hydronic Pumps Accessories www.soperssupply.com Industrial Soper s Supply Ltd. Proud Distributor of the Following

More information

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572 FEATURES Computer designed, efficient performance, forward curved blower. Blower wheel hub is secured to the shaft with a locking keyway. Blower is secured to anti-vibration mounts within the cabinet.

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Item No. Specifications Selection Performance Pump Sectional View Chart Curve Dimensions

Item No. Specifications Selection Performance Pump Sectional View Chart Curve Dimensions Model CDU, Contents CDU, Item No. Specifications Selection Performance Pump Sectional View Chart Curve Dimensions CDU70/1-3/4HP CDU70/3-1 1 /2HP CDU70/5-2HP CDU120/1-1HP CDU120/3-1 1 /2HP 3 5, 311 6 311

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

CHILLED WATER DUCTED FAN COIL

CHILLED WATER DUCTED FAN COIL SD CHILLED WATER DUCTED AN A Series B Series (Double Skin) General abricated with a rigid galvanized steel casing. The DIDW centrifugal fans have balanced, galvanized steel, and forward curved blades.

More information

DWO DWO DWO DWO

DWO DWO DWO DWO Model Contents Item No. Specifications Selection Performance Pump Sectional Motor Chart Curve Dimensions View Data 506 704 006 70 70 705 708 709 7 006 706 4006 707 www.pumpsebara.com 700 (t) 80 7-5005

More information

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN MODEL FEATURES Exhaust air up to 2,630 CFM with static pressure capabilities to 1 w.g. Mixed flow impeller for excellent air flow to pressure performance ratio

More information

DML - DMLF. SUBMERSIBLE SEWAGE PUMPS (SINGLE-CHANNEL) in cast iron. Your Life, our Quality. Worldwide. 67 Wastewater APPLICATIONS TECHNICAL DETAILS

DML - DMLF. SUBMERSIBLE SEWAGE PUMPS (SINGLE-CHANNEL) in cast iron. Your Life, our Quality. Worldwide. 67 Wastewater APPLICATIONS TECHNICAL DETAILS APPLICATIONS TECHNICAL DETAILS TECHNICAL DATA 40 mm (DMLF) DN50, DN55, DN65 (DMLF) MATERIALS ACCESSORIES (ON REQUEST) PUMP IDENTIFICATION CODE 80 DML DMLF 5 2,2 50 HZ 2,2 3,7 5,5 7,5 11 15 22 MODEL OUTPUT

More information

CLEARANCE ITEMS DATE: 2018 / 03 / 01

CLEARANCE ITEMS DATE: 2018 / 03 / 01 CLEARANCE ITEMS DATE: 2018 / 03 / 01 2 JAMES ELECTRIC MOTOR SERVICES LTD. 3M083D ACKLANDS-GRAINGER / DAYTON P/N 3M083 $63.35 HP AMPS PHASE RPM MOTOR ROTATION BEARING SHAFT DIA. BODY DIA. 1/20 1.8 1 1550

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 PERFORMANCE CHART A (up to 0.6 kw) 203 PERFORMANCE CHART A (from 0.75 kw up to 1.1 kw) 204 PERFORMANCE CHART A (1.3 kw) 205 PERFORMANCE

More information

FCVC Series VERTICAL FAN COILS

FCVC Series VERTICAL FAN COILS VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,

More information

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data Type series booklet CTI-2000/00 [09-2010] BEV Deep well vertical pumps 1. Fields of Application BEV are vertical multistage centrifugal pumps designed for deep well, ditches and tanks to pump clean liquids

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

Inside Front cover White

Inside Front cover White TUBE FAN Inside Front cover White INDEX INTRODUCTION PERFORMANCE GRAPHS TECHNICAL DATA DIMENSIONS pages - 3 - ACOUSTIC DATA - SOUND PRESSURE LEVEL ELECTRICAL DETAILS 3 4 Index back side white Introduction

More information

Vertical Floor Fan Coil Unit (Model FW)

Vertical Floor Fan Coil Unit (Model FW) Technical Bulletin Issue Date March 24, 2005 Vertical Floor Fan Coil Unit (Model FW) Figure 1: Model FWX Vertical Exposed Model FW Vertical Floor fan coil units are designed to maximize flexibility of

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 FITTINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 FITTINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 25/08 204 PERFORMANCE CURVE 25/15 205 PERFORMANCE CURVE 25/25 206

More information

AC centrifugal fan. forward-curved, single-intake with housing (flange)

AC centrifugal fan. forward-curved, single-intake with housing (flange) GE8-AA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

Address: VTS Clima L.L.C.

Address: VTS Clima L.L.C. Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS

More information

RADIAL ALUMINUM LOW PRESSURE

RADIAL ALUMINUM LOW PRESSURE RADIAL ALUMINUM LOW PRESSURE Content: LOW PRESSURE BLOWERS... 2 GENERAL... 3 D03M, E03... 4 D04M, E04... 5 D05M, E05... 6 D052M, E052... 7 D060, E060... 8 D064, E064... 9 D066, E066... 10 D07, D072...

More information

Single Phase AC Induction Electric Motors

Single Phase AC Induction Electric Motors Single Phase AC Induction Electric Motors Europe s original and finest electric motors providing legendary performance, reliability and engineering design. The AMME range of single phase are capacitor

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733 SH Series 60 Hz SERIE SH HYDRAULIC PERFORMANCE RANGE AT 60 Hz WEB 10-2006 2 CONTENTS 5 Specifications... 6

More information

CVM. EBARA PUMPS EUROPE S.p.A. MULTISTAGE CENTRIFUGAL PUMPS

CVM. EBARA PUMPS EUROPE S.p.A. MULTISTAGE CENTRIFUGAL PUMPS CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE A (UP TO 0.6 kw) 203 PERFORMANCE CURVE A (FROM 0.75 kw UP TO 1.1 kw) 204 PERFORMANCE CURVE

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX510-A October 2009 ADJUSTABLE PITCH PROPELLER FANS TYPE TCWPX TCWPX Adjustable Pitch Propeller Fans Sizes 24" 48" Direct Drive Belt Driven Heavy-Duty Construction Twin

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

FLOMAX SELF PRIMING CENTRIFUGAL PUMP FEATURES. 3 MP PUMPS, INC. PHONE: (800) FAX: (586) FLOMAX 5 FLOMAX 8

FLOMAX SELF PRIMING CENTRIFUGAL PUMP FEATURES. 3 MP PUMPS, INC. PHONE: (800) FAX: (586) FLOMAX 5 FLOMAX 8 FLOMAX 5 8 10 SELF PRIMING CENTRIFUGAL PUMP FEATURES CLOSED COUPLED TO ELECTRIC MOTOR PUMPAK ONLY TO MOUNT TO STANDARD NEMA C FACE MOTOR FLOWS - 100-750 GPM PRESSURES - 100-230 FEET HEAD AVAILABLE IN:

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN

More information

PRODUCT CATALOG 50 HZ MH SERIES HORIZONTAL MULTI-STAGE PUMPS. franklinwater.com

PRODUCT CATALOG 50 HZ MH SERIES HORIZONTAL MULTI-STAGE PUMPS. franklinwater.com PRODUCT CATALOG 5 Z M SERIES ORIZONTAL MULTI-STAGE PUMPS franklinwater.com 5 Z M SERIES ORIZONTAL MULTI-STAGE PUMPS Features...2 Applications...2 Model Nomenclature...2 Family Curve...3 Materials/Fluids

More information

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369 and annular chambers Application Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +00 C. Design Orifice plate with annular chambers consisting

More information

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable KD High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable Electrical accessories S-ET p. 341 The KD series have external rotor

More information

VERTICAL IN-LINE PUMP

VERTICAL IN-LINE PUMP VERTICAL IN-LINE PUMP TECHNICAL FEATURES ELINE: Vertical centrifugal pumps, single impeller, volute casing, non-self priming pump, in-line executive, with mechanical seal. Hydraulically designed in line

More information

Page - DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX 5/10/ PUMP TABLE MATRIX 5/10/ PACKING 403

Page - DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX 5/10/ PUMP TABLE MATRIX 5/10/ PACKING 403 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 3 ( 2-3 IMPELLERS ) 204 PERFORMANCE CURVE 3 ( 4-5-6 IMPELLERS )

More information

SUBMERSIBLE PUMPS WITH SEMI-OPEN IMPELLER FOR CLEAN WATER AND RAINWATER in cast iron

SUBMERSIBLE PUMPS WITH SEMI-OPEN IMPELLER FOR CLEAN WATER AND RAINWATER in cast iron Submersible pumps with semi-open impeller for clean water and rainwater. APPLICATIONS Purification tank drainage Rain and spring water drainage Water supply TECHNICAL DETAILS Efficient semi-open impeller

More information

SUBMERSIBLE PUMPS WITH SEMI-OPEN IMPELLER FOR CLEAN WATER AND RAINWATER in cast iron

SUBMERSIBLE PUMPS WITH SEMI-OPEN IMPELLER FOR CLEAN WATER AND RAINWATER in cast iron Submersible pumps with semi-open impeller for clean water and rainwater. APPLICATIONS Purification tank drainage Rain and spring water drainage Water supply TECHNICAL DETAILS Efficient semi-open impeller

More information