TECHNICAL INFORMATION HENRAD PREMIUM ECO RADIATOR YOUR IDEAL HEATING SOLUTION

Size: px
Start display at page:

Download "TECHNICAL INFORMATION HENRAD PREMIUM ECO RADIATOR YOUR IDEAL HEATING SOLUTION"

Transcription

1 ECO Technical documentation 2017 Export TECHNICAL INFORMATION HENRAD PREMIUM ECO RADIATOR YOUR IDEAL HEATING SOLUTION

2 ECO RANGE

3 WHY Green heat? WE CAN NO LONGER DENY IT: THE ENVIRONMENT IS SUFFERING BECAUSE OF OUR ENERGY CONSUMPTION. ENERGY CONSUMPTION TRANSPORT 31.3% INDUSTRY 28.3% We are all looking for SMARTER WAYS TO MANAGE ENERGY. Buildings are big consumers of energy and the majority of that consumption is for heating and hot water, so our sector has a great responsibility to innovate. With renewable energy and efficient heating and cooling technologies, OUR BUILDINGS CAN EMIT UP TO 60% LESS CO 2. The European Union helps carry the load by gradually making energy consumption standards stricter. And rightly so, because with a perfect energy balance, a modern house uses less than a tenth of what was possible 30 years ago. BUILDINGS 40.4% 85% Heating & hot water 15% Electricity Modern heating technologies and renewable energy are crucially important in order to achieve the ambitious objectives. To get the full benefits, such technologies need low temperature systems. That s where the green heat of Henrad ECO radiators comes in. Source: Green Paper on Energy Efficiency or Doing More with Less (March 2006). 3

4 SAVE ON YOUR ENERGY BILLS WITH THE Henrad Premium ECO Reduced energy bills More radiant heat Higher mean surface temperature on the front panel Quality verified and certificatied by ISSO UP TO 10.5% UP TO 50% UP TO 53% ISSO CERTIFIED energie-milieu/epa/ gelijkwaardigheidsverklaringen UP TO 23% UP TO 8.8% UP TO 6% Faster heat up process A decrease in energy loss through reduced radiation from the back panel Pre-set thermostatic valve means savings VALVE CAN BE FITTED ON THE LEFT OR THE RIGHT, QUICK CONNECTION, FEELING OF COMFORT MAINTAINED IN LOW TEMPERATURE SYSTEMS, SUITABLE FOR RENEWABLE ENERGY. REASON ENOUGH TO CHOOSE HEAT THAT IS GREEN.

5 MORE RADIATION = More comfort + lower costs! HEAT CAN BE TRANSFERRED IN DIFFERENT WAYS: THROUGH CONDUCTION, CONVECTION OR RADIATION. HOMES ARE HEATED MAINLY BY CONVECTION AND/OR RADIANT HEAT. With CONVECTION HEAT, the air in a room is heated as air flows pass over heating elements. The heated air rises, cools and falls again down the walls. The cooled air is then warmed up again by the heating system. In RADIANT HEAT, infra-red radiation is emitted to heat objects in the room directly, independently of air flows such as wind or draughts. Radiant heat gives the entire room including furniture, walls and people, a completely even temperature. These objects in turn yield their heat to the room, making it feel very comfortable. The best example of radiant heat is the sun. Standing in the sun, you feel the radiation on your skin, which immediately makes you feel warmer, even if the nearby ambient air in the shade is not cooler than the air directly in the sun. The only difference felt is the radiant heat. The HEAT TRANSFER from a traditional radiator is usually 80% by convection and 20% by radiation. The comfortable feeling of warmth from solar radiation is therefore less present in a traditional radiator, but the ECO radiator changes that. The photos below show that the heat transfer by radiation increases significantly in the ECO radiator. Especially the greater amount of radiation from the front panel is considered very pleasant. ECO RADIATOR * TRADITIONAL RADIATOR * After 8 minutes at a mass flow of 50% After 8 minutes at a mass flow of 50% After 8 minutes at a nominal mass flow After 8 minutes at a nominal mass flow * Test conditions: radiator type 22 (height = 600 mm, length = 1,000 mm) at 70/55/20 C. These measurements show that, at a nominal mass flow of 50% (good for more than 90% of the nominal emission of heat), the radiation capacity of the Type 21 and Type 22 ECO radiators increase by a factor of 1.5 compared with a traditional radiator. DEPENDING ON TYPE AND HEIGHT, THE ECO RADIATOR EMITS UP TO 50% MORE RADIANT HEAT. 5

6 The increased radiant heat is a direct consequence of the increased mean surface temperature of the front panel. An external test laboratory performed exhaustive tests on the ECO radiators, with the results shown below. The front panel of the ECO radiator has a mean temperature of 43 C after 2 minutes and 50 C after 3 minutes. At the same times, the front panel of a traditional radiator has mean temperatures of 28 C and 35.7 C respectively. According to the EN Standard, in practice there are only a few days in a year (on average ten) on which radiators use their maximum heat emission for a longer period of time. ECO radiators provide additional benefits even during these limited number of days of prolonged full load. After the ECO radiator has stabilised (i.e. is in full load), its front panel is up to 4% warmer than a traditional radiator TEMPERATURE C 63.0 TEMPERATURE C % + 40% % 18 TIME seconds TIME minutes ECO radiator Traditional radiator ECO radiator Traditional radiator AN ECO RADIATOR REACHES A SURFACE TEMPERATURE ON THE FRONT PANEL THAT IS UP TO 54% HIGHER AFTER 2 MINUTES AND A HIGHER FINAL TEMPERATURE UNDER FULL LOAD, THEREBY EMITTING UP TO 50% MORE RADIANT HEAT. Just like with the sun, the perceived temperature with the ECO radiator is higher than with a traditional radiator. In other words, at a constant perceived temperature of 20 C, the increased radiant heat from the ECO radiator allows the thermostat to be a few degrees lower.* * According to the BDH (Bundesindustrieverband Deutschland), setting your thermostat a few degrees lower means an energy saving of 6%. IN THIS WAY, ECO RADIATORS YIELD AN ENERGY SAVING OF AT LEAST 6%, WITHOUT REDUCING THE PERCEIVED TEMPERATURE.

7 FASTER HEATING-UP PROCESS Less CO 2 IN ADDITION TO MORE RADIANT HEAT AND THE HIGHER MEAN TEMPERATURE OF THE FRONT PANEL, THERE ARE VARIOUS FACTORS THAT REDUCE THE ENERGY BILL CONSIDERABLY IF YOU CHOOSE AN ECO RADIATOR. Thanks to its unique flow pattern, the ECO radiator s HEATING-UP TIME is significantly shorter than that of a traditional radiator. The DIRECT FLOW of water into the upward channel in the front panel. In a traditional radiator, the hot water first has to go through a series of rising channels before it is spread over the front and back panels. The front panel of the ECO radiator reaches its maximum temperature of 62.5 C after 8.5 minutes. At that moment, the front panel of a traditional radiator is at only 59.3 C and its maximum temperature is only reached after 11 minutes, by which time the ECO radiator will have already been at its maximum temperature for over 2.5 minutes. FRONT 63.0 TEMPERATURE C % BACK TIME minutes ECO radiator Traditional radiator The further DISTRIBUTION of the hot water: the hot water is spread evenly across the other channels of the front panel. A unique system then takes it to the back panel, where it is also spread over all the water channels. * Test conditions: type 22 radiator (height = 600 mm, length = 1,000 mm) at 70/55/20 C. THE ECO RADIATOR S FRONT PANEL REACHES ITS MAXIMUM TEMPERATURE UP TO 23% FASTER THAN THAT OF A TRADITIONAL RADIATOR. IN OTHER WORDS: THE ECO RADIATOR S FRONT PANEL IS ALREADY AT ITS MAXIMUM TEMPERATURE WHILE A TRADITIONAL RADIATOR STILL NEEDS A LONG TIME TO WARM UP. 7

8

9 FEWER LOSSES Higher effi ciency! BY FURTHER LIMITING ENERGY LOSSES, THE ECO RADIATOR SUCCEEDS IN INCREASING THE EFFICIENCY OF THE HEATING SYSTEM EVEN MORE. Not only is the front panel hotter during the entire heating-up process, even after stabilisation, but the BACK PANEL IS COLDER, which is just as important. Because the back panel usually faces an outside wall, there is a possible loss of radiation through the wall. The graph below shows the mean temperature of the back panel at specific moments during the heating-up process. The graph below shows the situation for both radiators after the heating system has stabilised. 63 TEMPERATURE C 63 TEMPERATURE C ,4% % ,7% ,7% % TIME seconds 54 TIME minutes ECO radiator back Traditional radiator back ECO radiator front Traditional radiator front ECO radiator back Traditional radiator back After 180 seconds, the mean temperature of the ECO radiator s back panel is 25.6 C, whereas a traditional radiator s is already 35 C. The ECO radiator s values after 5 and 7 minutes are 37.6 C and 47.8 C respectively, whereas the results for a traditional radiator are 48.1 C and 57.2 C. THERE IS STILL A SIGNIFICANT DIFFERENCE BETWEEN THE MEAN TEMPERATURES OF THE BACK PANELS OF THE TWO TYPES OF RADIATOR AFTER STABILISATION. THE TEMPERATURE OF THE ECO RADIATOR S BACK PANEL IS UP TO 7% LOWER COMPARED WITH THAT OF A TRADITIONAL RADIATOR. 9

10 In a traditional radiator, there is hardly any difference in temperature between the front and back panels. The radiant heat is emitted to the wall, and in the case of an outside wall, this heat is lost through it and energy loss occurs. TRADITIONAL RADIATOR ECO RADIATOR IN THE CASE OF THE ECO RADIATOR, THERE IS A WIDE DIFFERENCE IN TEMPERATURE BETWEEN THE TWO PANELS, WHICH CAN INCREASE TO OVER 12%.

11 PRE-SET Thermostatic valve THE THERMOSTATIC VALVE IS FACTORY-SET IN THE ECO RADIATOR IN RELATION TO THE SIZE OF THE RADIATOR, WHICH ENSURES OPTIMAL OUTPUT AND EFFICIENCY. In practice, OPTIMAL HYDRAULIC SETTING OF THE HEATING INSTALLATION is very important, certainly in view of rising energy costs. The planner or architect uses software to correctly calculate all the necessary parameters (mass flows or throughput, couplers and connectors, valve settings, etc.) for the hydraulic settings of the installation in new-build housing, which are then implemented by the installer. Factory pre-setting is possible because radiator dimensions do not differ infinitely. To be certain that small radiators with a low heat output and limited water content can be adjusted optimally, HENRAD HAS DECIDED TO USE TWO TYPES OF VALVE: a fine adjustment valve (Heimeier 4369 with a yellow top) especially for small radiators a standard valve (Heimeier 4368) with 4 different pre-sets (white, red, black and blue) for normal to large radiators A lot of this information gets lost as time passes, and adjustments and/or repairs made in the meantime make finding the correct settings in the event of restoration more complicated. A more PRACTICALLY- ORIENTED SOLUTION is to fit the radiators with a Kv pre-set valve in the factory. The principle is relatively simple: the valve ensures that at a given pressure difference the correct quantity of hot water or mass flow passes through the radiator. The PROPER PRE-SETTING OF THE VALVE means that the radiator s heat output is close to its nominal value. The valves in the ECO radiator are set so that the throughput in the radiator is equal to or a little higher than the nominal throughput. A minimum of extra throughput gives the heating system sufficient or a little more power, and the situation is brought close to its nominal or ideal state PERCENTAGE HEAT OUTPUT COMPARED WITH NORMAL OUTPUT % MASS THROUGHPUT COMPARED WITH NORMAL MASS THROUGHPUT % Increasing the throughput even more, which happens with an unregulated valve, gives relatively little extra power. This could cause other radiators to get insufficient hot water and therefore be unable to heat the room. 11

12 At Henrad, the KV SETTING OF RADIATORS IS SHOWN UNEQUIVOCALLY AND BY THE COLOUR: Reference Colour yellow white red black blue Pre-set value KV (at 1K) pre-set to Adjustment range (at 1K) Furthermore, Henrad valves are continuously adjustable (with tapered groove), which means that the mass flow can be controlled very accurately and there is less sensitivity to faults. This is in contrast to other valves that are difficult or impossible to align accurately and can become clogged because of impurities (such as chalk) in the water, which leads to their working poorly and to insufficient heating of the radiator. HENRAD VALVE OTHER VALVE The benefits of pre-setting are considerable: time-saving during installation. optimal water throughput in the radiator. higher system efficiency as a result of lower return temperatures. The BDH (Bundesindustrieverband Deutschland) has shown that factory pre-set valves have an extremely favourable effect on the hydraulic balance of a heating installation. THIS GIVES ENERGY SAVINGS OF UP TO 6% COMPARED WITH NON-BALANCED SYSTEMS. Furthermore, if pump consumption is taken into account, then a heating system with factory pre-set valves can give additional savings of up to 20% in the electricity the pump uses.

13 FACTORY PRE-SETTING PREMIUM ECO HEIGHT TYPE , , , , , , , , , , , , HYGIENE ECO HEIGHT TYPE , , , , , , , , , , , , Art Art Art Art Art pre-set 5.5 pre-set 2.5 pre-set 4.5 pre-set 6 pre-set 8 The factory settings of the pre-installed thermostatic valves were determined on the basis of the following preconditions: heat output at 70/55/20 C ( t = 15 C ). differential pressure p = 100 mbar. control difference 1K. In case of abnormal preconditions, the valve can be adjusted manually and precisely (or be replaced if necessary) through the pre-setting tables 4368 and 4369 (with setting key art. T1622). In one-pipe systems the valve should be adjusted to position 8. 13

14 MANUAL BALANCING Example 5.5 VALVE 4369 MAX. 1K CONTROL DIFFERENCE Radiator performance Q [W] t [K] p [mbar] Setting range ,000 1,200 1,400 1,600 1,800 2,000 2,200 2,400 2,600 2,800 3,000 3,200 3,400 3,600 3,800 4,000 4,800 5,300 6,500 6,800 7,200 MAX. 2K CONTROL DIFFERENCE Radiator performance Q [W] t [K] p [mbar] Setting range Q = Heat output p = Differential pressure t = Target: setting range 100 mbar = 10 kpa = 1mWS ,000 1,200 1,400 1,600 1,800 2,000 2,200 2,400 2,600 2,800 3,000 3,200 3,400 3,600 3,800 4,000 4,800 5,300 6,500 6,800 7,200 EXAMPLE Target: Given: Solution: setting range Premium ECO: Type 11 - Height Length 500 needs to operate at: 80/70/20 C, differential pressure: t = 50mbar pre-assembled valve: yellow pre-setting value: emission at 80/70/20 C: 790 Watt t = 10 C (80-70 C) according to the above table: P-band 1K (upper table): no setting possible. P-band 2K (lower table): no setting possible. pre-setting value according to table 4369: none (blank box) yellow valve 4369 must be replaced by white, red, black or bleu valve 4368 and readjusted at: P-band 1K: readjust at position 5 P-band 2K: readjust at position

15 MANUAL BALANCING Example VALVES 4368 MAX. 1K CONTROL DIFFERENCE Radiator performance Q [W] t [K] p [mbar] Setting range ,000 1,200 1,400 1,600 1,800 2,000 2,200 2,400 2,600 2,800 3,000 3,200 3,400 3,600 3,800 4,000 4,800 5,300 6,500 6,800 7,200 MAX. 2K CONTROL DIFFERENCE Radiator performance Q [W] t [K] p [mbar] Setting range Q = Heat output p = Differential pressure t = Target: setting range 100 mbar = 10 kpa = 1mWS ,000 1,200 1,400 1,600 1,800 2,000 2,200 2,400 2,600 2,800 3,000 3,200 3,400 3,600 3,800 4,000 4,800 5,300 6,500 6,800 7,200 EXAMPLE Target: Given: setting range Premium ECO: Type 22 - Height Length 1,400 needs to operate at: 60/40/20 C, differential pressure: t = 50mbar pre-assembled valve: red pre-setting value: emission at 60/40/20 C 1,008 Watt t = 20 C (60-40 C) 2 Solution: pre-setting value according to table 4368: P-band 1K: readjust at position 3 P-band 2K: readjust at position

16 PRESSURE DROP DIAGRAM Valve with integrated precision pre-setting (Art. 4369) 5.5 VALVE RADIATORS WITHOUT CONNECTION FITTINGS. 30 P-BAND [XP] 1.0 K P-BAND [XP] 2.0 K PRE-SETTING PRE-SETTING DIFFERENTIAL PRESSURE P [KPA] DIFFERENTIAL PRESSURE P [MBAR] DIFFERENTIAL PRESSURE P [KPA] DIFFERENTIAL PRESSURE [MBAR] Information received from Heimeier Valve radiators without fitting Thermostatic valve body with thermostatic head PRE-SETTING Thermostatic valve body p-band xp 1.0 K Kv value [m 3 /h] p-band xp 2.0 K Kv value [m 3 /h] Kv value [m 3 /h] Flow tolerance ± [%] Max. operating temp. TB* [ C] Max. operating pressure PB [bar] Permitted differential pressure, during which the valve is kept closed p [bar] Thermostatic head EMO T/NC EMOtec/NC EMO 1/3 EMO EIB/LON EMO T/NO EMOtec/NO * With protection cap or actuator 100 C SAMPLE CALCULATION Target: setting range Given: heat flow: Q = 350 Watt temperature spread: t = 15 K (65-50 C) pressure loss, valve radiator: p V = 32 mbar Solution: mass flow: m = Q = 350 = 20 kg/h c x t x 15 Setting range from diagram with P-band 1.0 K: 6 with P-band 2.0 K: 4

17 PRESSURE DROP DIAGRAM Standard valve (Art. 4368) VALVE RADIATORS WITHOUT CONNECTION FITTINGS P-BAND [XP] 1.0 K PRE-SETTING P-BAND [XP] 2.0 K PRE-SETTING DIFFERENTIAL PRESSURE P [KPA] DIFFERENTIAL PRESSURE P [MBAR] DIFFERENTIAL PRESSURE P [KPA] DIFFERENTIAL PRESSURE P [MBAR] Information received from Heimeier Valve radiators without fitting Thermostatic valve body with thermostatic head PRE-SETTING Thermostatic valve body p-band xp 1.0 K Kv value [m 3 /h] p-band xp 2.0 K Kv value [m 3 /h] Kv value [m 3 /h] Flow tolerance ± [%] Max. operating temp. TB* [ C] Max. operating pressure PB [bar] Permitted differential pressure, during which the valve is kept closed p [bar] Thermostatic head EMO T/NC EMOtec/NC EMO 1/3 EMO EIB/LON EMO T/NO EMOtec/NO * With protection cap or actuator 100 C SAMPLE CALCULATION Target: setting range Given: heat flow: Q = 1,135 Watt temperature spread: t = 15 K (65-50 C) pressure loss, valve radiator: p V = 30 mbar Solution: mass flow: m = Q = 1,135 = 65 kg/h c x t x 15 Setting range from diagram with P-band 1.0 K: 6 with P-band 2.0 K: 4 17

18 MORE SUITABLE FOR Renewable energy! THE ECO RADIATOR CAN BE COMBINED PERFECTLY WITH ALL TYPES OF LOW-TEMPERATURE SYSTEMS SUCH AS HEAT PUMPS, SOLAR PANELS AND BIOMASS INSTALLATIONS. Considering the limited number of days a year that a radiator has to operate at MAXIMUM HEAT OUTPUT, partial heating with a mass flow of 10-30% will be sufficient to heat a room during 90 to 95% of the heating periods. The radiator s mean surface temperature will be lower during these periods. The desired room temperature will be achieved by a traditional radiator with a surface temperature of less than 40 C, but it will not feel as comfortable. Thanks to its serial flow, the ECO radiator has a higher front panel temperature, which gives off up to 50% MORE RADIANT HEAT. It is precisely this increased radiation that maintains a comfortable feeling, even at lower mass flows. This is extra important when replacing an obsolete heating system that operates at high temperature with a modern system that operates at a lower temperature and uses renewable energy sources such as heat pumps or solar panels. ECO radiators are therefore PERFECT FOR USE IN HEATING INSTALLATIONS THAT HAVE BEEN CONVERTED FROM A HIGH- TEMPERATURE SYSTEM TO A LOW-TEMPERATURE SYSTEM such as heat pumps.

19 OTHER BENEFITS! VALVE CAN BE FITTED ON THE LEFT OR THE RIGHT The valve can be fitted on the left or the right of the ECO radiator without having to adapt the return pipe. No separate part numbers, no separate stock, no extra price for a left-hand version, and yet still the same short delivery time as for a radiator with the valve on the right. CENTRE CONNECTION There is a ¾ conical male Euroconus connection in the middle of the ECO radiator. This means that the location of the connection no longer depends on the length of the radiator, with the benefit that pipes can be installed at an early stage of the project without having to know the size of the radiator. There is also an additional ½ female connection underneath at the right. INPUT ALWAYS ON THE LEFT The input on all multi-panel ECO radiators (T21, T22 and T33) has to be connected on the left, irrespective of whether the valve is fitted on the left or on the right. CONNECTION FACILITIES FOR RENOVATION AS WELL AS NEW CONSTRUCTION This ECO radiator has an additional ½ female connection underneath at the right specifically for the renovation market. This is in addition to the ¾ conical male Euroconus centre connection that is often used in new construction projects. EASIER TESTING Using our installation template enables the heating installation and the pipes to be fully tested without the radiators having to be in place. QUICK CONNECTION The ¾ conical male Euroconus centre connection allows the pipes to be connected directly to the ECO radiator without an intermediate coupler. This reduces the risk of leakage and makes installation faster. APART FROM THE UNIQUE FEATURES ALREADY MENTIONED, THE ECO RADIATOR ALSO OFFERS NUMEROUS OTHER ADVANTAGES FOR END USER INSTALLERS AS WELL AS WHOLESALERS. 19

20 TECHNICAL INFORMATION Henrad Premium ECO THE HENRAD LOW-TEMPERATURE VALVE RADIATOR WITH SERIAL FLOW TECHNOLOGY, BOTH A CENTRE AND LATERAL BOTTOM CONNECTION AND A PRE-SET VALVE INSERT, WHICH CAN BE FITTED ON THE LEFT OR RIGHT SIDE OF THE RADIATOR. Low-temperature panel radiator made from high-quality steel, with serial flow technology (water flows first through the front panel). This results in high energy efficiency, maximum radiation (even in low-temperature heating systems), faster heating rate and less waste of energy. Optimised in accordance with the requirements of EN442, EN12831 and DIN Quality assurance in accordance with ISO Heat output tested in accordance with EN442. Product quality certified by RAL. Galvanised version available on demand. FINISHING Upper grille and side panels PRE-INSTALLED Pre-set Heimeier 4368 or 4369 valve insert, ECO air vent and blind plugs VALVE INSERT The integrated adjustable valve insert (without thermostatic head) is factory-fit on the right side of the radiator, CEN certified, tested in accordance with EN215 and compatible with thermostatic heads M30 x 1.5 mm. For types the valve insert can also be fitted on the left side of the radiator, a left version for a type 11 radiator is available on request. The thermostatic valve insert is factory-set in relation to the size of the radiator. This pre-setting ensures optimum throughput in the radiator. Factory setting for two-pipe systems, also suitable for one-pipe systems (as long as the valve insert is adjusted to position 8). ALSO SUPPLIED VDI brackets (type Monclac), screws, plugs and installation instructions CONNECTIONS 2 x ¾ male Eurocone centre connection and 2 x ½ female lateral bottom connection LUGS 2 pairs of mounting lugs up to 1,600 mm and 3 pairs from 1,800 mm PACKAGING Every radiator is sturdily packaged in high-quality cardboard and wrapped in plastic. The radiator s characteristics are shown on the label: type height length WARRANTY 10 years, as long as the installation instructions have been followed and Henrad s warranty conditions have been met PAINT PROCESS All radiators are degreased, phosphated, cataphoretically primed and powder-coated in Henrad white 9016 as standard COLOUR Henrad white different Henrad colours and about 200 RAL-colours are possible HEAT COST ALLOCATOR Suitable for heat cost allocators, both electronic and according to the evaporation principle (covered by the norm of EN834 & EN835). MAX. OPERATING PRESSURE 10 bar (tested to 13 bar) MAX. OPERATING TEMPERATURE 110 C CONFORMITY In accordance with EN442 QUALITY ASSURANCE RAL and NF DECLARATION OF EQUIVALENCE ISSO and Kiwa TYPES HEIGHTS mm LENGTHS 400-3,000 mm DEPTHS mm

21 Type overview * CALCULATION FACTOR PER METRE OF RADIATOR LENGTH AT 75/65/20 C IN ACCORDANCE WITH EN442 CHARACTERISTIC COMPARISON: Φ = K M ΔT N. HEIGHT (mm) TYPE 11 TYPE 21 TYPE 22TYPE 33 W ,347 kg l m² n W ,173 1,686 kg l m² n W 8331,107 1,401 2,007 kg l m² n W 9801,287 1,617 2,313 kg l m² n W 1,1171,467 1,824 2,607 kg l m² n W 1,3601,836 2,220 3,180 kg l m² n W = output per metre kg = weight per metre l = water content per metre m² = surface area per metre n = exponent TYPE 11 TYPE 21 TYPE 22TYPE * The manufacturer retains the right to make changes to the products without prior notice. 21

22 Output overview SUPPLIED ACCESSORIES: PRE-SET HEIMEIER VALVE INSERT, ECO AIR VENT, VDI BRACKETS, SCREWS, PLUGS AND INSTALLATION INSTRUCTIONS. HEIGHT 300 mm 400 mm 500 mm TYPE W/m EN442 55/45/20 C 259 W 387 W 479 W 684W 346 W 480 W 602 W 856 W 428 W 571 W 720 W 1,019 W ,000 1,100 1,200 1,400 1,600 1,800 2,000 2,200 2,400 2,600 2,800 3, , , ,339 1,006 1,488 1,118 1,637 1,230 1,786 1, , , , ,493 1,116 1,679 1,255 1,866 1,394 2,053 1,534 2,239 1,673 2,426 1,813 2,612 1,952 2,799 2, , , ,347 1,002 1,482 1,102 1,616 1,202 1,886 1,402 2,155 1,602 2,425 1,803 2,694 2,003 2,963 2,203 3,233 2,404 3,502 2,604 3,772 2,805 4,041 3, , , ,352 1, , , , ,483 1,112 1,669 1,252 1,854 1,391 2,039 1,529 2,225 1, , , , ,408 1,052 1,642 1,227 1,877 1,403 2,111 1,578 2,346 1,753 2,581 1,929 2,815 2,104 3,050 2,280 3,284 2,455 3,519 2, , , ,349 1,003 1,517 1,128 1,686 1,254 1,855 1,379 2,023 1,504 2,360 1,755 2,698 2,006 3,035 2,257 3,372 2,507 3,709 2,758 4,046 3, , , , ,499 1,121 1,666 1,246 1,833 1,371 1,999 1, , , , ,550 1,161 1,771 1,326 1,993 1,493 2,214 1,658 2,435 1,824 2,657 1, , , ,401 1,047 1,541 1,152 1,681 1,257 1,961 1,466 2,242 1,676 2,522 1,885 2,802 2,095 3,082 2,304 3,362 2,513 3,643 2,723 3,923 2,933 4,203 3, , , ,405 1,045 1,606 1,194 1,806 1,343 2,007 1,492 2,208 1,642 2,408 1,791 2,810 2,090 3,211 2,388 3,613 2,687 4,014 2,985 4,415 3,283 4,817 3,582 Delivery times depend on the model: consult with your wholesaler.

23 EN442 (W) EN442 (W) 75/65/20 C 70/50/20 C HEIGHT 600 mm 700 mm 900 mm TYPE W/m EN442 55/45/20 C ,000 1,100 1,200 1,400 1,600 1,800 2,000 2,200 2,400 2,600 2,800 3, W 662 W 831 W 1,174 W 577 W 751 W 938 W 1,323 W 703 W 933 W 1,142 W 1,615 W , , ,372 1,028 1,568 1,175 1,764 1,322 1,960 1,469 2,156 1,616 2,352 1, , , , ,416 1,059 1,544 1,155 1,802 1,347 2,059 1,540 2,317 1,733 2,574 1,925 2,831 2,117 3,089 2, , , ,455 1,088 1,617 1,209 1,779 1,330 1,940 1,450 2,264 1,693 2,587 1,934 2,911 2,176 3,234 2,418 3,557 2,659 3,881 2,902 4,204 3,143 4,528 3,385 4,851 3, , ,388 1,032 1,619 1,204 1,850 1,376 2,082 1,548 2,313 1,720 2,544 1,892 2,776 2,064 3,238 2,408 3,701 2,752 4,163 3,096 4,626 3,440 5,089 3,784 5,551 4, , , , ,340 1,004 1,564 1,172 1,787 1,339 2,011 1,507 2,234 1, , , , ,467 1,095 1,614 1,205 1,760 1,314 2,054 1,533 2,347 1,752 2,641 1,972 2,934 2, , , ,459 1,091 1,642 1,228 1,824 1,364 2,006 1,500 2,189 1,637 2,554 1,910 2,918 2,182 3,283 2,455 3,648 2,728 1, , ,564 1,163 1,825 1,357 2,086 1,551 2,346 1,745 2,607 1,939 2,868 2,133 3,128 2,326 3,650 2,714 4,171 3,102 4,693 3,490 5,214 3, , , ,360 1,019 1,496 1,121 1,632 1,223 1,904 1,427 2,176 1,631 2,448 1,835 2,720 2, , , ,469 1,093 1,652 1,229 1,836 1,366 2,020 1,503 2,203 1,639 2,570 1,913 2,938 2,186 3,305 2,459 3,672 2, , , ,554 1,162 1,776 1,328 1,998 1,495 2,220 1,661 2,442 1,827 2,664 1,993 3,108 2,325 3,552 2,657 3,996 2,989 4,440 3,321 1, ,590 1,183 1,908 1,419 2,226 1,656 2,544 1,892 2,862 2,129 3,180 2,365 3,498 2,602 3,816 2,838 4,452 3,311 5,088 3,784 5,724 4,257 6,360 4,730 23

24 TECHNICAL INFORMATION Henrad Hygiene ECO THE LOW-TEMPERATURE VALVE RADIATOR SPECIFICALLY DEVELOPED FOR ENVIRONMENTS WHERE HYGIENE AND SAFETY ARE ALL-IMPORTANT, WITH SERIAL FLOW TECHNOLOGY, BOTH A CENTRE AND LATERAL BOTTOM CONNECTION AND A PRE-SET VALVE INSERT, WHICH CAN BE FITTED AND THE LEFT OR RIGHT SIDE OF THE RADIATOR. Low-temperature panel radiator made from high-quality steel, with serial flow technology (water flows first through the front panel). This results in high energy efficiency, maximum radiation (even in low-temperature heating systems), faster heating rate and less waste of energy. Optimised in accordance with the requirements of EN442, EN12831 and DIN Quality assurance in accordance with ISO Heat output tested in accordance with EN442. Product quality certified by RAL. Galvanised version available on demand. FINISHING Without upper grille or side panels PRE-INSTALLED Pre-set Heimeier 4368 or 4369 valve insert, ECO air vent and blind plugs VALVE INSERT The integrated adjustable valve insert (without thermostatic head) is factory-fit on the right side of the radiator, CEN certified, tested in accordance with EN215 and compatible with thermostatic heads M30 x 1.5 mm. For types 20 and 30 the valve insert can also be fitted on the left side of the radiator, a left version for a type 10 radiator is available on request. The thermostatic valve insert is factory-set in relation to the size of the radiator. This pre-setting ensures optimum throughput in the radiator. Factory setting for two-pipe systems, also suitable for one-pipe systems (as long as the valve insert is adjusted to position 8). ALSO SUPPLIED Installation instructions CONNECTIONS 2 x ¾ male Eurocone centre connection and 2 x ½ female lateral bottom connection LUGS 2 pairs of mounting lugs up to 1,600 mm and 3 pairs from 1,800 mm PACKAGING Every radiator is sturdily packaged in high-quality cardboard and wrapped in plastic. The radiator s characteristics are shown on the label: type height length WARRANTY 10 years, as long as the installation instructions have been followed and Henrad s warranty conditions have been met PAINT PROCESS All radiators are degreased, phosphated, cataphoretically primed and powder-coated in Henrad white 9016 as standard COLOUR Henrad white different Henrad colours and about 200 RAL-colours are possible HEAT COST ALLOCATOR Suitable for heat cost allocators, both electronic and according to the evaporation principle (covered by the norm of EN834 & EN835) MAX. OPERATING PRESSURE 10 bar (tested to 13 bar) MAX. OPERATING TEMPERATURE 110 C CONFORMITY In accordance with EN442 QUALITY ASSURANCE RAL and Hygiene TYPES HEIGHTS mm LENGTHS 400-3,000 mm DEPTHS mm

25 Type overview * CALCULATION FACTOR PER METRE OF RADIATOR LENGTH AT 75/65/20 C IN ACCORDANCE WITH EN442 CHARACTERISTIC COMPARISON: Φ = K M ΔT N. HEIGHT (mm) TYPE 10 TYPE 20TYPE 30 W kg l m² n W ,074 kg l m² n W ,275 kg l m² n W 610 1,023 1,470 kg l m² n W 699 1,167 1,659 kg l m² n W 877 1,458 2,034 kg l m² n W = output per metre kg = weight per metre l = water content per metre m² = surface area per metre n = exponent 25 TYPE 10 TYPE 20TYPE * The manufacturer retains the right to make changes to the products without prior notice. 25

26 Output overview SUPPLIED ACCESSORIES: PRE-SET HEIMEIER VALVE INSERT, ECO AIR VENT AND INSTALLATION INSTRUCTIONS. HEIGHT 300 mm 400 mm 500 mm TYPE W/m EN442 55/45/20 C ,000 1,100 1,200 1,400 1,600 1,800 2,000 2,200 2,400 2,600 2,800 3, W 306 W 447 W 222 W 381 W 553 W 268 W 457 W 655 W , , , , , , , , , ,055 1, , , ,025 1, ,231 1, , , , ,171 1, ,406 2, , , ,056 1,525 1,053 1, ,318 1, ,582 2, , , ,189 1,716 1,170 1, ,464 2,148 1,042 1,758 2, , ,101 1, ,321 1,906 1,287 1,907 1,610 2,363 1,146 1,934 2, ,428 1,211 1, ,453 2,097 1,404 2,081 1,757 2,578 1,250 2,110 3,060 1,057 1,558 1,321 1, ,585 2,288 1,521 2,254 1,903 2,285 1,145 1,688 1,431 1,717 1,638 2,428 2,050 2,461 1,234 1,818 1,542 1,849 1,755 2,601 2,196 2,637 1,322 1,947 1,652 1,981 Delivery times depend on the model: consult with your wholesaler.

27 EN442 (W) EN442 (W) 75/65/20 C 70/50/20 C HEIGHT 600 mm 700 mm 900 mm TYPE W/m EN442 55/45/20 C ,000 1,100 1,200 1,400 1,600 1,800 2,000 2,200 2,400 2,600 2,800 3, W 530 W 754 W 356 W 603 W 850 W 444 W 749 W 1,038 W , , , , ,021 1, , , , ,166 1, , , ,050 1, ,312 1, , , ,023 1, ,167 1, ,458 2, , , ,090 1, ,125 1, ,284 1, ,604 2, , , ,199 1, ,228 1, ,400 1,991 1,052 1,750 2, , ,049 1, ,308 1, ,432 2, ,634 2,323 1,228 2,041 2, ,075 1, ,224 1, ,526 2, ,637 2,352 1,118 1,867 2,654 1,403 2,333 3, ,228 1, ,399 1,982 1,043 1,744 2,426 1,098 1,841 2,646 1,258 2,101 2,986 1,579 2,624 3, ,382 1, ,574 2,229 1,173 1,962 2,729 1,220 2,046 2,940 1,398 2,334 3,318 1,754 2,916 4, ,535 2,196 1,041 1,749 2,477 1,303 2,180 3,032 1,342 2,251 3,234 1,001 1,689 2,416 1,464 2,455 3,528 1,092 1,842 2,636 2,660 1,996 2,864 2,149 3,069 2,303 27

28 Connection options VALVE CAN BE FITTED ON THE LEFT OR THE RIGHT. VIEW: Front radiator. TYPE TYPE Valve left* Valve right Valve left Valve right * On demand. Installation template CONNECTION SIZES TYPE TYPE TYPE Front Cross section mm mm mm mm ½ Bottom side radiator ¾ EUROKONUS 50 L/2 L ¾ EUROKONUS L/2 50 2x 1 2 " mm mm " Cross section Front TYPE Cross section " T1642 (Including spacer) 2x 1 2x EUROKONUS 2 " Bottom side radiator L: Length (from 400 to 3,000 mm) Minimum distance to bottom of radiator: 120 mm.

29 Wall brackets CORNER BRACKET TYPE 10 J-BRACKET (FOR VDI 6036) TYPE HEIGHT (mm) X Y Art. No. (2 pcs.) Art. No. (3 pcs.) R R Y R R R R X R R Bottom side radiator R R R R TYPE 10 TYPE 11 TYPE TYPE 22 TYPE x 2x Art. No. T1507 2x 2x 2x 29

30 Mounting lug positions TYPE 11 L/2 + 17mm A A A A L: 400-1,600 TYPE 10, TYPE A A L: 1,800-3,000 L A , L/2 A A L: L: L A (TYPE 10) A (TYPE 20-33) , ,200-3,

31 COLOUR YOUR WARMTH How to order a coloured radiator Select the radiator s item number then the colour code and colour description, e.g SN170 Black Warmth is indispensable for a snug home. Just like an interior in which you feel good. A place to come home to. When choosing Henrad you are also choosing colourful warmth. NATURAL COLOURS NT110 Papyrus white NT120 Pearl white NT130 Champagne NT140 Beige NT150 Beige grey NT160 Pebble grey NT170 Quartz grey METALLIC COLOURS ML110 ML120 ML130 ML140 ML150 ML160 ML170 Dove grey Titanium Blue grey Granite Cappuccino Terra Graphite grey brown black SANITARY COLOURS SN110 Cream white SN120 Cream SN130 Mocca SN140 Bordeaux SN150 Sepia SN160 Pale blue SN170 Black RAL COLOURS A1004 Golden yellow A2003 Pastel orange A3002 Carmine red A5002 Ultramarine blue A6018 Yellow green A7001 Silver grey A7011 Iron grey A7016 Anthracite grey A7030 Stone grey A7035 Light grey A8017 Chocolate brown A9003 Signal white A9005 Jet black A9010 Pure white The colours are illustrative only.

32 FOR MORE INFORMATION, CONTACT HENRAD Algeria Australia Belgium Cyprus Czech Republic France Germany Greece Iceland Lithuania Luxembourg The Netherlands Poland Russia Slovenia Sweden Tunisia Ukraine HENRAD Henrad N.V. Welvaartstraat 14 bus Herentals Belgium T F HR ECO TD EN /11

COMPACT WITH STYLE HORIZONTAL & LO-LINE

COMPACT WITH STYLE HORIZONTAL & LO-LINE COMPACT WITH STYLE HORIZONTAL & LO-LINE The subtle architectural look and feel of the Stelrad Compact with Style is combined with value, range and availability to give you sophisticated designer styling

More information

RANGE EXTENSION. Any room. Any home. Any lifestyle.

RANGE EXTENSION. Any room. Any home. Any lifestyle. RANGE EXTENSION Any room. Any home. Any lifestyle. Contents 03/05 Arno Towel Rail Range 04 - Arno Single 04 - Arno Double 05 - Arno Curved Towel Rail 06 Verona Towel Rail 07/10 Verona Range 08 - Verona

More information

DECORATIVE COLLECTION CONCORD RAIL

DECORATIVE COLLECTION CONCORD RAIL Aqua Series DECORATIVE COECTION CONCORD RAI The Stelrad Concord Rail offers a stunning alternative to tubular towel rails, with its flat tube on tube. Offering visual appeal combined with advanced technology,

More information

Aqua Series. Kitchen & Bathroom Collection

Aqua Series. Kitchen & Bathroom Collection Aqua Series Kitchen & Bathroom Collection 02 LEADING THE WAY 01 Stelrad has been manufacturing high quality, steel radiators since 1936, so it s safe to say we know a thing or two about heating. Since

More information

Market leading prices from your market leader. Radiator Book

Market leading prices from your market leader. Radiator Book Market leadg prices from your market leader. Radiator Book LEADING THE WAY on quality, PRICE & design Stelrad has been manufacturg high quality, steel radiators sce 1936, so it s safe to say we know a

More information

RADIK RC. energy saving panel radiators RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC

RADIK RC. energy saving panel radiators RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RADIK RC RC energy saving panel radiators RC RC RC RC RC RC 2/2016 Radik RC for your comfort We need a radiant heat component for our own satisfaction and a pleasant feeling of thermal

More information

... heat for you. Flat panel and decorative radiators

... heat for you. Flat panel and decorative radiators ... heat for you Flat panel and decorative radiators 10/2010 The new plant KORADO is the most modern factory for the production of radiators in Europe thanks to its up-to date production facility, technology

More information

RTL. Floor Heating Controller Return temperature limiter with and without presetting

RTL. Floor Heating Controller Return temperature limiter with and without presetting RTL Floor Heating Controller Return temperature limiter with and without presetting IMI HEIMEIER / Floor Heating Control / RTL RTL Among other things, the return temperature limiter RTL is used to limit

More information

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control Dynacon Automatic Flow Control Floor Heating Manifolds Floor heating manifold with automatic flow control IMI HEIMEIER / Floor Heating Control / Dynacon Dynacon Dynacon adjusts the flow rate in the individual

More information

BERNSTEIN Aluminium Control Enclosure

BERNSTEIN Aluminium Control Enclosure BERNSTEIN Aluminium Control Enclosure Protection in its most beautiful form The new Aluminium Control Enclosure Design aspects along with modularity, functionality and ergonomics, are rapidly becoming

More information

Ascotherm eco KRP91 Natural convection

Ascotherm eco KRP91 Natural convection KRP91 Natural convection Tender specification, range available and sizes Tender specification Version KRP91 Natural Convection Ready-to-install floor pan for the floor area. Operating principle natural

More information

Aluminium rolling grilles. stylish protection for your property

Aluminium rolling grilles. stylish protection for your property Aluminium rolling grilles stylish protection for your property An ideal solution for shops and boutiques, shopping malls and stores, offices and banks, cafés and restaurants, underground garages and parking

More information

Aluminium rolling grilles. stylish protection for your property

Aluminium rolling grilles. stylish protection for your property Aluminium rolling grilles stylish protection for your property Ideal solution for shops and boutiques, shopping malls and stores, offices and banks, café and restaurants, underground garages and parking

More information

COMPACT XPANEL RADIATORS XCOMPACT

COMPACT XPANEL RADIATORS XCOMPACT XPANEL RADIATORS XCOMPACT COMPACT The Compact 4-connector profile radiator is fitted with 4 x ½ BSP connections at the side. The vertical profile is 33 mm and this in combination with the convection fins

More information

ambiente wood burning stoves

ambiente wood burning stoves ambiente wood burning stoves Are you looking for a stove with an individual character? Then the ambiente range by Spartherm is just what you need. The ambiente line combines simple, timeless design with

More information

July Panel Radiator & Towel Radiator. Product Catalogue. warmhaus.com

July Panel Radiator & Towel Radiator. Product Catalogue. warmhaus.com July 2018 Product Catalogue Panel Radiator & Towel Radiator warmhaus.com CONTENT About Warmhaus Production & Delivery Product Range Standard Panel Radiators Compact Panel Radiators Hygienic Panel Radiators

More information

VOGEL&NOOT. Tube radiators. heatingthroughinnovation.

VOGEL&NOOT. Tube radiators. heatingthroughinnovation. VOGEL&NOOT Tube radiators. heatingthroughinnovation. 02 Contents Contents. Cloakroom Living room Kitchen Introduction 03 Laserline Standard 04 Laserline Twin 06 Laserline Architecture 08 Bathroom Bedroom

More information

Floor heating manifold with automatic flow control

Floor heating manifold with automatic flow control dynacon Floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage dynacon adjusts the flow rate in the individual

More information

aplano plus Distinctively elegant vertical radiators

aplano plus Distinctively elegant vertical radiators aplano plus Distinctively elegant vertical radiators Aplano Plus Dimensions Product code: APP C 121 90 air vent G 1/8 2.5 25 45 70 95 H 300 410 520 630 740 8 C 160 270 380 490 600 710 100 70 6 88 min.

More information

PLAN COMPACT VENTIL PANEL RADIATORS PLAN COMPACT VENTIL

PLAN COMPACT VENTIL PANEL RADIATORS PLAN COMPACT VENTIL PANEL RADIATORS The Plan Compact Ventil combines the timeless beautiful elegance of a perfectly flat front with the advantages of an integrated valve connection. It has a perfect panel front, so that from

More information

... heat for you KORALUX. towel rail radiators - technical catalogue

... heat for you KORALUX. towel rail radiators - technical catalogue ... heat for you KORAUX towel rail radiators - technical catalogue 04/2016 A quick access to most recent information Read us in your mobile phone You can view our offer also in your mobile phone. You just

More information

Schüco Premium Collectors Outstanding quality, performance and design

Schüco Premium Collectors Outstanding quality, performance and design Schüco Premium Collectors Outstanding quality, performance and design 2 Schüco Premium collectors Schüco Premium line collectors - The next generation Since its entry into the solar thermal sector, Schüco

More information

dynacon floor heating manifold with automatic flow control

dynacon floor heating manifold with automatic flow control dynacon floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage Dynacon Description HEIMEIER Dynacon floor heating

More information

Mikrotherm F. Manual Radiator Valves With presetting

Mikrotherm F. Manual Radiator Valves With presetting Mikrotherm F Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Mikrotherm F The Mikrotherm F manual radiator valve is used in warm water pump heating

More information

CONCORD PLANE & LO-LINE

CONCORD PLANE & LO-LINE CONCORD PLANE & LO-LINE The Stelrad Concord creates a distinctive look for any room, with four super-stylish design options - from the Lo-Line at just 144mm high to the Vertical at up to 2 metres, and

More information

VERTICAL RADIATOR. Technical data. Profile radiator. Connections 4 x G 1/2 I.G. Test positive pressure 13 bar

VERTICAL RADIATOR. Technical data. Profile radiator. Connections 4 x G 1/2 I.G. Test positive pressure 13 bar Technical data 45 VERTICAL Profile radiator Connections 4 x G 1/2 I.G 13 bar Test positive pressure 13 bar 10 bar max. Max. positive operating pressure e 10 bar max. Max. operating temperature 110 10 C

More information

TESI STEEL MULTI COLUMN RADIATORS COMMERCIAL HEATING SOLUTIONS

TESI STEEL MULTI COLUMN RADIATORS COMMERCIAL HEATING SOLUTIONS TESI COMMERCIAL HEATING SOLUTIONS 2 A brand of IRSAP, Italy s leading manufacturer of design led radiators. /6 04.09.18 Units 13-14 Charlwoods Road East Grinstead, West Sussex, RH19 2HU www.clyderadiators.co.uk

More information

Mechatronic brake system INTORQ Control

Mechatronic brake system INTORQ Control Mechatronic brake system INTORQ Control for industrial trucks, escalators and cranes setting the standard The mechatronic brake system = INTORQ Control + INTORQ BFK458 spring-applied brake Spring-applied

More information

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE TECHNICAL BROCHURE aesthetic performance flexibility thermal comfort PREMIUM QUALITY MECHANICAL STRENGTH IMPROVE CHANGE LIGHTNESS savings high resistance to corrosion low and high temperature systems FULL

More information

Ascotherm eco KC481 Heating and cooling in 4-conductor system

Ascotherm eco KC481 Heating and cooling in 4-conductor system KC481 Heating and cooling in 4-conductor system Tender specification, range available and sizes Tender specification Version KC481 heating and cooling in 4-conductor system Ready-to-install floor pans

More information

Portable Compressors MOBILAIR M 122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min

Portable Compressors MOBILAIR M 122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min www.kaeser.com Portable Compressors MOBILAIR M 122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min Worldwide sales and service network KAESER is one of the world s foremost compressor

More information

Hudevad Integral Hygiene

Hudevad Integral Hygiene Technical datasheet Key benefits Historical Kundenedfald Grøn energi Swedish high quality steel Highly robust and durable Healthcare Public Sikkerhed Energi C Rengøring Panels spaced for easy access Fast

More information

SUPERIA. superia. superia RADIATORS BROCHURE EXPORT 2017 A BRAND OF VASCO GROUP

SUPERIA. superia. superia RADIATORS BROCHURE EXPORT 2017 A BRAND OF VASCO GROUP A BRAND OF VASCO GROUP RADIATORS BROCHURE EXPORT 2017 SUPERIA RADIATOREN BVBA Remi Claeysstraat 66 8210 Zedelgem T +32 (0)50-20 94 61 F +32 (0)50-20 94 64 info@.be www..be VASCO GROUP NV Kruishoefstraat

More information

STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS

STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS STAINLESS STEEL MANIFOLDS FOR RADIANT SYSTEMS CREATION AND DIFFUSION OF THE STAINLESS STEEL MANIFOLD USE DIAGRAMS OF STAINLESS STEEL MANIFOLDS www.itap.it CREATION AND DIFFUSION OF THE STAINLESS STEEL

More information

Hudevad Standard. Technical datasheet

Hudevad Standard. Technical datasheet Technical datasheet Key benefits $ Swedish high quality steel Highly robust and durable Pressure tested at high pressure Approved for district heating Historical Kundenedfald Highly flexible in size Huge

More information

ErP Directive ErP Implementing Regulation 327/2011. The new minimum efficiencies for electrically powered blowers and the impact on Elektror devices

ErP Directive ErP Implementing Regulation 327/2011. The new minimum efficiencies for electrically powered blowers and the impact on Elektror devices ErP Directive ErP Implementing Regulation 327/2011 The new minimum efficiencies for electrically powered blowers and the impact on Elektror devices Your air technology partner The legal provisions Background

More information

Regutec F. Return Lockshield Radiator lockshield

Regutec F. Return Lockshield Radiator lockshield Regutec F Return Lockshield Radiator lockshield IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regutec F Regutec F The Regutec lockshield is used in pumped warm water heating and air conditioning

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

USE AN ENGINEERED APPROACH TO TAILOR A PERFECT STANDARD GAS SPRING FOR YOUR DESIGN A GUIDE TO GAS SPRING DESIGN AND CUSTOMIZATION WH ITE PA P E R

USE AN ENGINEERED APPROACH TO TAILOR A PERFECT STANDARD GAS SPRING FOR YOUR DESIGN A GUIDE TO GAS SPRING DESIGN AND CUSTOMIZATION WH ITE PA P E R WH ITE PA P E R USE AN ENGINEERED APPROACH TO TAILOR A PERFECT STANDARD GAS SPRING FOR YOUR DESIGN A GUIDE TO GAS SPRING DESIGN AND CUSTOMIZATION When your machine design calls for an industrial gas spring,

More information

T6-PLAN CENTRALLY CONNECTED RADIATOR.

T6-PLAN CENTRALLY CONNECTED RADIATOR. 50 T6-PLAN CENTRALLY CONNECTED RADIATOR Technical data T6-PLAN CENTRALLY CONNECTED RADIATOR. Connections 4 x internal thread G 1/2 and 2 x external thread G 3/4 bottom centre 10 bar max. Max. positive

More information

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION PRODUCT DATA Application 011 Angle to DIN Angle to NF Straight to DIN Straight to NF Thermostatic radiator valve bodies (TRV

More information

Permanent magnet brakes. Safety from the market leader. PM Line High Torque Line

Permanent magnet brakes. Safety from the market leader. PM Line High Torque Line Permanent magnet brakes Safety from the market leader PM Line High Torque Line Industrial Drive Systems Die Welt von Kendrion Industrial Drive Systems Kendrion The brake experts As a solution provider,

More information

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. October 2016

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. October 2016 PRESS EMBARGO: NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1 October 2016 Next press release: Thursday 22 December 2016 1 Data for Malta unavailable Page 1 of 7 Commercial vehicle registrations:

More information

ACTIVENT System. Specifications. Product code example ACTA

ACTIVENT System. Specifications. Product code example ACTA Activent is a ventilation system for supplying and distributing air. The system has been proven to function effectively in both small and large areas and is used in all types of premises ranging from offices

More information

Hudevad Standard Hygiene

Hudevad Standard Hygiene Technical datasheet Key benefits Historical Kundenedfald Grøn energi Swedish high quality steel Highly robust and durable Rengøring Panels spaced for easy access Fast and easy cleaning between panels Highly

More information

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB. Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise

More information

67 th edition. Renewable energy. Appendices. 44 Other renewables consumption 45 Biofuels production

67 th edition. Renewable energy. Appendices. 44 Other renewables consumption 45 Biofuels production Renewable energy 44 Other renewables consumption 45 Biofuels production Appendices A1 Solar Generation A2 Wind Generation A3 Geothermal, biomass and other Generation A4 Geothermal Cumulative installed

More information

Better sealing solutions for reciprocating compressors

Better sealing solutions for reciprocating compressors Better sealing solutions for reciprocating compressors Experience and know-how the basis for innovation Rings and packings are critical components for the service life of reciprocating compressors. Therefore

More information

ACEA Report. Vehicles in use Europe 2017

ACEA Report. Vehicles in use Europe 2017 ACEA Report Vehicles in use Europe 2017 TABLE OF CONTENTS Summary... 2 Vehicles in use in Europe... 3 Passenger cars... 3 Light commercial vehicles... 4 Medium and heavy commercial vehicles... 5 Buses...

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION CLC/TS 50591 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION November 2013 ICS 45.060.10 English version Specification and verification of energy consumption for railway rolling

More information

Stradaflair. Strada Trench Convectors. Strada Flat Panel Range. Strada Radiant Skirting. Strada Heated & Chilled Ceilings. Strada Electrical Products

Stradaflair. Strada Trench Convectors. Strada Flat Panel Range. Strada Radiant Skirting. Strada Heated & Chilled Ceilings. Strada Electrical Products Other Strada Products Strada Trench Convectors 2No. Models, Hot Water and Electric Strada Flat Panel Range Aluminium & Steel for ceiling & wall mounting Strada irad Stradafloor Strada Hi-Rad Strada Hi-Rad

More information

MODERNISATION SOLUTIONS. MRM W Line. TIME FOR A FACE-LIFT!

MODERNISATION SOLUTIONS. MRM W Line.  TIME FOR A FACE-LIFT! MODERNISATION SOLUTIONS TIME FOR A FACE-LIFT! ADVANCED FEATURES WITTUR SOLUTION FOR MODERNISATION The, Wittur flexible machine roomless electric lift, offers an ideal solution for new lifts in existing

More information

The BERNSTEIN CS-3000

The BERNSTEIN CS-3000 Flexible and efficient: The BERNSTEIN CS-3000 Designers and manufacturers expect modern suspension systems to feature variable configuration, progressive design and complete ease installation. BERNSTEIN

More information

Hudevad Flat Front. Technical datasheet

Hudevad Flat Front. Technical datasheet Technical datasheet Key benefits $ Completely sealed casing Clean and tamper-proof design Pressure tested at high pressure Approved for district heating Historical Kundenedfald Highly flexible in size

More information

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. December 2018

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. December 2018 PRESS EMBARGO: NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1 December 2018 Commercial vehicle registrations: +3.2% in 2018; 4.0% in December Total new commercial vehicles In December 2018, commercial

More information

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery DATA & FACTS Unit Heaters MultiMAXX HB Quick Selection and Fast Delivery Table of Contents MultiMAXX HB Unit Type Code... 3 About this Catalogue... 4 Overview of Capacity... 5 Unit Description... 6 Unit

More information

Hudevad LK. Technical datasheet

Hudevad LK. Technical datasheet Technical datasheet Key benefits Kundenedfald Grøn energi Swedish high quality steel Highly robust and durable Fully welded solution No removable parts, making it highly durable and completely tamper-proof

More information

THE LUXURY RANGE CONTENTS. The Luxury Range Introduction. Eurovault Lx Grade 2 Size 2. Made in Yorkshire. Eurovault Lx Grade 2 Size 3.

THE LUXURY RANGE CONTENTS. The Luxury Range Introduction. Eurovault Lx Grade 2 Size 2. Made in Yorkshire. Eurovault Lx Grade 2 Size 3. 2014 /15 THE LUXURY RANGE CONTENTS 4 The Luxury Range Introduction 18 Eurovault Lx 2 Size 2 6 Made in Yorkshire 20 Eurovault Lx 2 Size 3 8 s & Sizes 22 Eurovault Lx 3 Size 1 10 Eurovault Lx 1 Size 1 24

More information

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function Pre-assembled distribution manifolds for radiant panel systems series & / NA Function Distribution manifolds for radiant panel systems are used to optimally distribute the heating fluid in floor heating

More information

English version. This Technical Specification was approved by CENELEC on

English version. This Technical Specification was approved by CENELEC on TECHNICAL SPECIFICATION CLC/TS 60034-31 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION February 2011 ICS 29.160 English version Rotating electrical machines - Part 31: Selection of energy-efficient motors

More information

MODERNISATION SOLUTIONS. MRM W Line. T I M E T O M A X I M I Z E YO U R S P A C E!

MODERNISATION SOLUTIONS. MRM W Line.   T I M E T O M A X I M I Z E YO U R S P A C E! MODERNISATION SOLUTIONS www.wittur.com T I M E T O M A X I M I Z E YO U R S P A C E! ADVANCED FEATURES WITTUR SOLUTION FOR MODERNISATION The, Wittur flexible machine roomless electric lift, offers an ideal

More information

W: 750 / H: 350 W: 500 / H: 350 W: 750 / H: 350 W: 500 / H: 350 W: 750 / H: 395 W: 500 / H: 395 W: 750 / H: 350 W: 500 / H: 350 W: 395 / H: 350

W: 750 / H: 350 W: 500 / H: 350 W: 750 / H: 350 W: 500 / H: 350 W: 750 / H: 395 W: 500 / H: 395 W: 750 / H: 350 W: 500 / H: 350 W: 395 / H: 350 USM Haller System The basic construction element of USM Modular Furniture Haller is a chrome-plated brass ball joint. Chromed steel tubes connect to the ball to form a stable framework in which the powder-coated

More information

T6-PLAN HYGIENE CENTRALLY CONNECTED RADIATOR.

T6-PLAN HYGIENE CENTRALLY CONNECTED RADIATOR. Technical data 59 T6-PLAN HYGIENE CENTRALLY CONNECTED RADIATOR. T6 PLAN HYGIENE Connections 4 x internal thread G 1/2 and 2 x external thread G 3/4 bottom centre 13 bar 10 bar max. max. Test positive pressure

More information

TECHNICAL CATALOGUE PANEL RADIATORS PURMO 05/2017

TECHNICAL CATALOGUE PANEL RADIATORS PURMO 05/2017 TECHNICAL CATALOGUE PANEL RADIATORS PURMO 05/2017 RETTIG ICC INTRODUCTION THE POWER OF A WORLD RANKING COMPANY Rettig ICC markets a variety of top brands, well-known to professionals in the heating business

More information

PANEL RADIATORS. Price list valid from March 01, 2018

PANEL RADIATORS. Price list valid from March 01, 2018 PANEL RADIATORS MADE IN YEARS POLAND WARRANT Y 1 Price list valid from March 01, 2018 2 CONTENT PERFEKT panel radiators compact radiators valve radiators retrofit radiators style radiators hygienic radiators

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

three-way mixing valve

three-way mixing valve three-way mixing valve with or without presetting, for heating and cooling systems. Pressurisation & Water Quality alancing & Control Thermostatic Control engineering avantage Three-way mixing valve, with

More information

USDA Agricultural Outlook Forum 2007

USDA Agricultural Outlook Forum 2007 USDA Agricultural Outlook Forum 2007 EU BIOFUELS POLICY AND EFFECTS ON PRODUCTION, CONSUMPTION AND LAND USE FOR ENERGY CROPS Hilkka Summa Head of Unit for Bioenergy, Biomass, Forestry and Climate Change

More information

WLTP for fleet. How the new test procedure affects the fleet business

WLTP for fleet. How the new test procedure affects the fleet business WLTP for fleet How the new test procedure affects the fleet business Editorial Ladies and Gentlemen, The automotive industry is facing a major transformation process that will also affect the fleet business

More information

Technical catalogue decorative and bathroom radiators, fan convectors POLAND 2013

Technical catalogue decorative and bathroom radiators, fan convectors POLAND 2013 Technical catalogue decorative and bathroom radiators, fan convectors POLAND 2013 table of contents decorative radiators type overview...4 bathroom radiators type overview... 36 Kos H...6 Santorini, Santorini

More information

something new in the air Technical Bulletin

something new in the air Technical Bulletin something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological

More information

THE WITTUR ANSWER TO THE MACHINE ROOMLESS MARKET REQUIREMENTS. MRL W Line. EMOTION IN MOTION

THE WITTUR ANSWER TO THE MACHINE ROOMLESS MARKET REQUIREMENTS. MRL W Line.   EMOTION IN MOTION THE WITTUR ANSWER TO THE MACHINE ROOMLESS MARKET REQUIREMENTS EMOTION IN MOTION ADVANCED FEATURES THE WITTUR ANSWER TO THE CURRENT MRL MARKET REQUIREMENTS The, Wittur s new generation of machine roomless

More information

PERFECTLY POSITIONED FOR ANY CHASSIS.

PERFECTLY POSITIONED FOR ANY CHASSIS. SUSPENSION SPRINGS PERFECTLY POSITIONED FOR ANY CHASSIS. Egon von RUVILLE GmBH Billbrookdeich 112 22113 Hamburg Germany Tel.: +49 40 73344-0 Fax: +49 40 73344-199 info@ruville.de www.ruville.de NEW IN

More information

THE ARCHITECTURAL BRANDS

THE ARCHITECTURAL BRANDS THE A RC H IT ECT U RA L B R A N DS W I N O N A P E E R L E S S M A R K A R C H I T E C T U R A L L I G H T I N G H Y D R E L RAL POLYESTER POWDER COAT COLOR The Architectural Brands of Hydrel, Mark Architectural

More information

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function Manifolds in composite specifically designed for radiant panel systems 670 series cert. n 000 ISO 900 CALEFFI 06/05 GB Function Manifolds in composite are used to control and distribute the fluid in the

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION CLC/TS 50537-3 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION February 2010 ICS 29.180; 45.060.10 English version Railway applications - Mounted parts of the traction transformer

More information

ELEVATOR ACCORDING TO MACHINE DIRECTIVE. HHL W Line FOR A SUSTAINABLE WORLD FREE OF BARRIERS.

ELEVATOR ACCORDING TO MACHINE DIRECTIVE. HHL W Line FOR A SUSTAINABLE WORLD FREE OF BARRIERS. ELEVATOR ACCORDING TO MACHINE DIRECTIVE HHL W Line FOR A SUSTAINABLE WORLD FREE OF BARRIERS www.wittur.com ADVANCED FEATURES HHL W Line A NEW WORLD FREE OF STAIRS The HHL W Line, Wittur s machine roomless

More information

Multi directional heating. Air heaters Model NOZ

Multi directional heating. Air heaters Model NOZ Multi directional heating Air heaters Model NOZ Air heaters The ideal heat source for large buildings Air heaters are used for the heating and ventilation of large industrial buildings. New industrial

More information

Staging the fire without wasting energy

Staging the fire without wasting energy Staging the fire without wasting energy Thermal comfort > operates either as an open fire or as a glass-door stove > cheats in 2 different ways : direct radiation and natural convection > the partial opening

More information

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. November 2018

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. November 2018 PRESS EMBARGO: NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1 November 2018 Commercial vehicle registrations: +3.8% 11 months into 2018; +2.7% in November Total new commercial vehicles In November

More information

STRADA. Better for you, better for the environment

STRADA. Better for you, better for the environment STRADA Better for you, better for the environment Strada Dimensions Product code: STRW d B h H h 90 L 123 6 Twin L 6 Type B d h (min) 06 8 0 100 10-11 118 2 100 1-16 168 77 120 20-21 218 102 10 Dimensions

More information

Taxing Petrol and Diesel

Taxing Petrol and Diesel Taxing Petrol and Diesel Colm Farrell Key Point Under the polluter pays principle, tax rates on diesel and petrol fuels should be at a rate which is commensurate with the total environmental costs they

More information

THE SELF USE SMART GRID INVERTER NEW GENERATION

THE SELF USE SMART GRID INVERTER NEW GENERATION Y o u r P o w e r, Y o u r R u l e s THE SELF USE SMART GRID INVERTER NEW GENERATION INVERTER ALL-IN-ONE SYSTEM BACK-UP MANAGEMENT EFFICIENCY (1) INSTALLATION OPERATION & INTERFACE MONITORING ABOUT IMEON

More information

Evacuated tube collectors

Evacuated tube collectors Evacuated tube collectors Evacuated tube collectors The overall performance of ecological heating systems based on solar thermal energy is significantly dependent on how efficiently the solar collector

More information

Smart balancing system Series SB Main features

Smart balancing system Series SB Main features Smart balancing system Series SB Main features Control system for radiant heating Innovative solution for auto-dynamic balancing Easy installation and start-up Dynamic adjustment to the operating point

More information

Portavant Glass fittings with logic

Portavant Glass fittings with logic Portavant Glass fittings with logic NEW! Smooth cushioning, gentle closing COMFORT STOP AUTOCLOSE DESIGN SELECT Portavant the innovative system for glass sliding doors sets new standards COMFORT STOP COMFORT

More information

BREXIT AND THE AUTO INDUSTRY: FACTS AND FIGURES

BREXIT AND THE AUTO INDUSTRY: FACTS AND FIGURES BREXIT AND THE AUTO INDUSTRY: FACTS AND FIGURES GLOBAL TRADE European Union EU vehicle imports: Total value: 48,019 million Quantity: 3,640,975 units EU vehicle exports: Total value: 138,536 million Quantity:

More information

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. April 2017

NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1. April 2017 PRESS EMBARGO: NEW COMMERCIAL VEHICLE REGISTRATIONS EUROPEAN UNION 1 April 2017 Next press release: Friday 23 June 2017 1 Data for Malta unavailable Page 1 of 7 Commercial vehicle registrations: +3.8%

More information

Butterfly valves for open-close applications and control mode

Butterfly valves for open-close applications and control mode I II III Butterfly valves for open-close applications and control mode Table of contents Introduction Butterfly valves for open-close applications Project planning, design and dimensioning 4 Butterfly

More information

Temperature Calibration Guide

Temperature Calibration Guide Temperature Calibration Guide Three Series SIKA divides temperature calibrators into three series. Depending on your requirements, up to 24 models are available. Reasons for a calibration TP Basic Efficiency

More information

Laboratorieglas Byretter (ISO 385:2005)

Laboratorieglas Byretter (ISO 385:2005) SVENSK STANDARD SS-EN ISO 385:2005 Fastställd 2005-07-11 Utgåva 1 Laboratorieglas Byretter (ISO 385:2005) Laboratory glassware Burettes (ISO 385:2005) ICS 17.060; 71.040.20 Språk: engelska Publicerad:

More information

NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE EUROPEAN UNION 1 Quarter

NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE EUROPEAN UNION 1 Quarter PRESS EMBARGO: NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE EUROPEAN UNION 1 Quarter 3 2017 Alternative fuel vehicle registrations: +51.4% in third quarter of 2017 In the third quarter

More information

Hudevad Integral. Technical datasheet

Hudevad Integral. Technical datasheet Technical datasheet Key benefits $ Sleek flat front Minimalistic design Pressure tested at high pressure Approved for district heating Historical Kundenedfald Highly flexible in size Huge range of dimensions

More information

INDIA S FIRST 4 Star Rated Technology Inverter

INDIA S FIRST 4 Star Rated Technology Inverter INDIA S FIRST 4 Star Rated Technology Inverter 89.57* DC-AC Label Period: 11th Aug, 2014-31st Dec, 2016 Low energy consumption Energy efficient More back up Low running cost DC Bus Voltage Waveform : Inverters

More information

H u d e v a d S C Te c h n i c a l d a t a s h e e t

H u d e v a d S C Te c h n i c a l d a t a s h e e t Hudevad SC Te c h n i c a l d a t a s h e e t Key benefits Historical Traditional craftsmanship Completely handmade unique design Fully soldered solution No removable parts making it completely tamper-proof

More information

SAFETY, INNOVATION AND DESIGN THE NEXX SHIELD SYSTEM

SAFETY, INNOVATION AND DESIGN THE NEXX SHIELD SYSTEM SAFETY, INNOVATION AND DESIGN By embracing and internalizing safe design, our engineers and designers can use it to their advantage as a new strategy and source for innovation NEXX Helmets innovations

More information

VARTA Energy Storage Systems

VARTA Energy Storage Systems VARTA Energy Storage Systems 130 Years of Battery Expertise in Your Energy Storage System. The perfect combination of long-term experience and modern technology. www.varta-storage.com GOOD REASONS FOR

More information

Shut-off and butterfly valves for open-close applications and control mode

Shut-off and butterfly valves for open-close applications and control mode I II III Shut-off and butterfly valves for open-close applications and control mode Table of contents Introduction Shut-off and butterfly valves for open-close applications Project planning, design and

More information

NEW. Special plasters

NEW. Special plasters NEW pico-rock selectt Special dental arch stone Discover the new dentale arch stone with fascinating properties. For extremely fine processing - with maximum hardness as a result. Working time: Vacuum

More information

Status Review on Smart Metering

Status Review on Smart Metering Status Review on Smart Metering Silke Ebnet & Stefan Santer Workshop 14 December 2009 Introduction Need for a status review and detailed analysis of smart meters in Europe was expressed at the first CEF

More information