Ascotherm eco KRP91 Natural convection
|
|
- Janice Conley
- 6 years ago
- Views:
Transcription
1 KRP91 Natural convection Tender specification, range available and sizes Tender specification Version KRP91 Natural Convection Ready-to-install floor pan for the floor area. Operating principle natural convection. Operating principle Cold air from the window area and cool room air drop in the floor pan. The air is heated by the heat register, becomes lighter and rises. Due to the installation in front of window areas a specific shielding against cold air is provided. For more information, see chapter "General information". Sturdy floor pan made of galvanised sheet steel, coated in anthracite grey (RAL 7016), external, adjustable and acoustically decoupled height adjustments (pre-installed). Heat register consisting of copper pipes and aluminium fins, anthracite grey (RAL7016) coated and mounted in transversal steel girders made of galvanised sheet steel, acoustically decoupled. Standard on the face or room side euro taper connection with union nut ( 3 / 4 internal thread) and air vent. Suitable for a max. operating pressure of 10 bar (optionally 16 bar) and a max. operating temperature of 110 C. Aluminium linear as standard. Acoustic decoupling through placement of the aluminium linear on rubber elements in the floor pan. Consisting of sturdy longitudinal profile bars, natural colour anodised, with profile bar dimensions of 16 x 6 mm. Grille with a total height of 20 mm and an open crosssection of 60%. Including installation cover and edge bar protection for protecting the trench convectors during the construction phase. Heat outputs tested and determined in acc. with Pr DIN EN 164, Part 1 and 2. QA system certified according to DIN EN ISO 9001:2008. Environmental management system according to DIN EN ISO 14001:2004. Suitable for closed water heating systems in accordance with DIN and water quality in accordance with VDI 2035, ÖNORM H5195 and SWKI BT Operating conditions: Hot water up to 110 C Operating pressure: Test pressure: Max. 10 bar (optionally 16 bar high-pres- sure-version) 13 bar (21 bar) Ascotherm eco KRP91 General Trench convectors find application in private residential areas, in conservatories, in offices and administration buildings, in showrooms as well as in business premises. Version KRP91 Natural Convection Connections: 2 x euro taper with union nut ( 3 / 4 internal thread), suitable for use with all fittings that comply with DIN V 3838 Air vent: installed Range available 6 depths: 185, 210, 260, 310, 360 and 400 mm 4 heights: 92, 120, 1 und 200 mm 17 lengths: from 1000 mm to 00 mm Grading 2 mm Standard: Aluminium linear Surface finishes Standard colour of floor pan, powder-coated: Anthracite grey (RAL7016 matt finish) Standard colour of linear : Aluminium anodised in natural colour Standard colour of edge bar: Aluminium, anodised in natural colour Accessories Digital room thermostat Programmable room thermostat Electric actuator 2 V AC Room thermostat with remote control Connection set, consisting of valve base with factory preset k V valve and return fitting with shut-off For additional accessories and information about accessories, see "Accessories". s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 5
2 Ascotherm KRP91 Natural convection Technical data per metre Technical data per metre Height mm Ascotherm eco KRP91 Height H Depth T Φ L T K 75/65/20 C [watts/m ribbed convector length] Φ T K 70/55/20 C [watts/m ribbed convector length] Heat output Φ T K 55/45/20 C [watts/m ribbed convector length] Φ T 25K /40/20 C [watts/m ribbed convector length] Exponent n [ ] Spec. standard water flow rate q ms [kg/h m] Mass per metre (average) M [kg/m] ,60 24,8 9, , 27,2 9, ,43 31,7 11, ,33 40,8 13, ,35 48,9 15, ,33 54,3 17, ,53,5 10, , 33,5 11, ,43 40,8 12, ,44 48,9 15, ,43 57,1 17, , 63,4 18, ,55 36,2 11, ,44 47,8 12, ,47 57,1 14, ,45 66,1 17, ,47 74,1 19, , 81,5 21, ,52 43,9 13, ,45 52,6 14, ,46 62,5 16, ,46 75,2 18, ,46 97,2 21, ,48 112,7 22,85 For individual calculations of heat outputs, see "General Information" 6 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
3 KRP91 Natural convection Dimensional drawings and connection images 2-pipe connections without integrated valve Connection system Ordering code IVTI Arrangement ANB Connection size Ordering code VG RG Additional price per radiator 2-pipe, room side, side by side 2-pipe, on the face side, side by side 2 BB DD Euro taper with union nut internal thread 3 / Ascotherm eco KRP91 Special connection 66/ 88 2-pipe, facing down, side by side 2 The accessories range does not contain any connection sets with preset valves for the connection arrangements 66 and 88; however, these can be installed at the factory with appropriate notification when ordering. Valve base with factory preset k v valve = Outflow 3 / 4 external thread with euro taper, inflow 1 / 2 internal thread; return fitting with shut-off: both sides 3 / 4 external thread with euro taper On request Dimensional drawings KRP91 Connection BB/DD Side view from left Front view Side view from right T H1 H T-33 H3 H L Ø19 Ø33 Top view Lber. ribb. Dimensional drawings for connection BB, connection DD mirrored T H H1 H2 H s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 7 L L ribb. up to 00 L over 00 L - 360
4 KRP91 Natural convection Dimensional drawings and connection images Dimensional drawings KRP91 Connections 11/33 Side view from left Front view Side view from right T Ascotherm eco KRP91 H1 T-33 Ø33 L H T2 Top view L ribb. ber. H2 H3 T1 NA Ø19 Dimensional drawings for connection 11, connection 33 mirrored T H H1 H2 H T T1 T2 Boss spacing , , L L ribb. up to 00 L over 00 L Pressure loss diagram for heights 92 and 120 mm Pressure loss diagram for heights 1 and 200 mm T 185, T 210 Pressure loss p [mbar/m ribbed convector length] T 185, T 210 T 260 T 310 T 400 T 360 Pressure loss p [mbar/m ribbed convector length] T 260 T 310 T 400 T Water flow q m [kg/h] Water flow q m [kg/h] 8 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
5 KRP91 Natural convection s and heat outputs Height 92 mm (depth mm) Version KRP91 KRP91 KRP91 Depth T Exponent n [ ] 1,60 1, 1,43 per piece [EUR/pc.] 87,14 119,18 124,15 per metre [EUR/m] Length L Ribbed convector length Lribb T [K] without linear Φ [watts] ,12 LR: Aluminium linear, natural colour anodised (standard) with linear 204,04 200,26 291,18 228,54 3,19 256,82 393,20 285,10 444,21 313,38 495,22 341,66 546,23 369,94 597,24 398,22 648,25 6, 699,26 454,78 7,27 483,06 801,28 511,34 852,29 539,62 903, 567,90 954,31 596, ,32 624, ,33 652, ,34 without linear Φ [watts] ,60 with linear 256,25 279,78 375,43 319,93 439,49 360,08 3,56 400,23 567,62 440,38 631,68 480,53 695,74 520,68 759,81 560,83 823,87 600,98 887,93 641,13 951,99 681, ,06 721, ,12 761, ,18 801, ,24 841, ,31 882, ,37 922, ,43 Ribbed convector length = length floor pan mm, for length > 00 mm: length floor pan mm without linear Φ [watts] ,09 with linear 269,72 285,24 393,87 325,51 461, 365,79 528,73 406,06 596,16 446,33 663,59 486,60 731,02 526,88 798,45 567,15 865,88 607, 933,31 647, ,74 687, ,17 728, ,60 768, ,03 808, ,46 849, ,89 889, ,32 929, ,75 Ascotherm eco KRP91 Standard heat output at 75 / 65 / 20 C ( T K), Φ=Φ S s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 9
6 KRP91 Natural convection s and heat outputs Height 92 mm (depth mm) Ascotherm eco KRP91 Version KRP91 KRP91 KRP91 Depth T Exponent n [ ] 1,33 1,35 1,33 per piece [EUR/pc.] 141,38 157,62 164,92 per metre [EUR/m] Length L Ribbed convector length Lribb T [K] without linear Φ [watts] ,49 LR: Aluminium linear, natural colour anodised (standard) with linear 299,74 8,87 441,12 3,74 516,06 392,62 590,99 434,49 665,93 476,36 740,86 518,23 815,80 560,11 890,73 601,98 965,67 643, ,60 685, ,54 727, ,47 769, ,41 811, ,34 853, ,28 895, ,21 936, ,15 978, ,08 without linear Φ [watts] ,53 with linear 361,95 373,15 519,57 7,03 610,06 480,92 700,55 534,80 791,03 588,68 881,52 6,56 972,01 696, , 7, ,98 804, ,47 858, ,96 911,98 14,45 965, , , , 1073, , , , , , , ,37 Ribbed convector length = length floor pan mm, for length > 00 mm: length floor pan mm without linear Φ [watts] ,51 with linear 370,85 378,43 535,77 431,81 628,48 485,19 721,20 538,56 813,91 591,94 906,62 645,32 999,33 698, ,05 752, ,76 805, ,47 858, ,18 912, ,90 965, , , , , , , , , , , ,17 Standard heat output at 75 / 65 / 20 C ( T K), Φ=Φ S 10 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
7 KRP91 Natural convection s and heat outputs Height 120 mm (depth mm) Version KRP91 KRP91 KRP91 Depth T Exponent n [ ] 1,53 1, 1,43 per piece [EUR/pc.] 110,52 144,49 156,95 per metre [EUR/m] Length L Ribbed convector length Lribb T [K] without linear Φ [watts] ,56 LR: Aluminium linear, natural colour anodised (standard) with linear 228,48 248,08 339,00 282,47 396,12 316,86 453,24 351,25 510,36 385,64 567,48 0,03 624,60 454, 681,72 488,81 738,84 523,20 795,96 557,59 853,08 591,98 910,20 626,37 967,32 660, ,44 695, ,56 729, ,68 763, ,80 798, ,92 without linear Φ [watts] ,33 with linear 288,98 337,82 433,47 386,15 5,72 434,49 577,96 482,82 6,21 531,15 722,45 579,48 794,70 627,82 866,94 676,15 939,19 724, ,43 772, ,68 821, ,92 869, ,17 917,81 10,41 966, , , , , , , ,39 Ribbed convector length = length floor pan mm, for length > 00 mm: length floor pan mm without linear Φ [watts] ,46 with linear 3,09 351,41 460,04 400,03 535,81 448,64 611,59 497,26 687,36 545,87 763,13 594,49 838,90 643,10 914,68 691,72 990,45 740, ,22 788, ,99 837, ,77 886, ,54 934, ,31 983, , , , , , , ,40 Ascotherm eco KRP91 Standard heat output at 75 / 65 / 20 C ( T K), Φ=Φ S s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 11
8 KRP91 Natural convection s and heat outputs Height 120 mm (depth mm) Ascotherm eco KRP91 Version KRP91 KRP91 KRP91 Depth T Exponent n [ ] 1,44 1,43 1, per piece [EUR/pc.] 181,95 216,91 227,76 per metre [EUR/m] Length L Ribbed convector length Lribb T [K] without linear Φ [watts] ,69 LR: Aluminium linear, natural colour anodised (standard) with linear 333,94 383,64 515,89 434,06 599,38 484,49 682,86 534,91 766,35 585,33 849,83 635,75 933,32 686, ,80 736, ,29 787, ,77 837, ,26 887,87 13,74 938, ,23 988, , , , , , , , , ,65 without linear Φ [watts] ,08 with linear 391, 461,99 608,41 523,26 706,29 584,53 804,16 645,80 902,04 707,07 999,91 768, ,79 829, ,66 890, ,54 952, , , 1489, , , , , , , , 1880, , , , ,54 14, ,41 Ribbed convector length = length floor pan mm, for length > 00 mm: length floor pan mm without linear Φ [watts] ,07 with linear 410,41 480,83 638,17 544,10 740,77 607,37 843,38 670,63 945,98 733, ,58 797, ,18 860, ,79 923, ,39 986, ,99 10, , , , , , , ,40 13, , , ,61 19, , , ,81 Standard heat output at 75 / 65 / 20 C ( T K), Φ=Φ S 12 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
9 KRP91 Natural convection s and heat outputs Height 1 mm (depth mm) Version KRP91 KRP91 KRP91 Depth T Exponent n [ ] 1,55 1,44 1,47 per piece [EUR/pc.] 116,05 151,76 159,71 per metre [EUR/m] Length L Ribbed convector length Lribb T [K] without linear Φ [watts] ,80 LR: Aluminium linear, natural colour anodised (standard) with linear 247,72 272,85 363,77 312,05 5,70 351,25 487,63 390,45 549,56 9,65 611,49 468,85 673, 8,05 735,35 547,25 797,28 586,45 859,21 625,65 921,14 664,85 983,07 704, ,00 743, ,93 782, ,86 821,65 12,79 860, ,72 900, ,65 without linear Φ [watts] ,94 with linear 9,59 365,70 461,35 419,19 538,75 472,67 616,15 526,16 693,54 579,64 770,94 633,13 848,34 686,61 925,74 740, ,13 793, ,53 847, ,93 900, ,33 954, , , , , , , , , , , ,71 Ribbed convector length = length floor pan mm, for length > 00 mm: length floor pan mm without linear Φ [watts] ,79 with linear 319, 370, 479,13 3,20 558,99 475,90 638,84 528,59 718,70 581,29 798,55 633,99 878,41 686,69 958,26 739, ,12 792, ,97 844, ,83 897, ,68 9, , , , , , , , , , , ,81 Ascotherm eco KRP91 Standard heat output at 75 / 65 / 20 C ( T K), Φ=Φ S s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 13
10 KRP91 Natural convection s and heat outputs Height 1 mm (depth mm) Ascotherm eco KRP91 Version KRP91 KRP91 KRP91 Depth T Exponent n [ ] 1,45 1,47 1, per piece [EUR/pc.] 188,35 223,23 234,40 per metre [EUR/m] Length L Ribbed convector length Lribb T [K] without linear Φ [watts] ,22 LR: Aluminium linear, natural colour anodised (standard) with linear 352,47 408,57 540,82 463,63 628,94 518,68 717,06 573,74 805,17 628,79 893,29 683,85 981,41 738, ,53 793, ,64 849, ,76 904, ,88 959,12 12, , , , , , , , , , , ,45 19,70 without linear Φ [watts] ,20 with linear 411,62 488,43 634,85 554,73 737,76 621,03 840,66 687,33 943,57 753, ,47 819, ,38 886, ,28 952, , , , , , , , , , , ,71 13, , , , , , , ,33 Ribbed convector length = length floor pan mm, for length > 00 mm: length floor pan mm without linear Φ [watts] ,74 with linear 431,08 8,14 665,48 576,58 773,25 645,01 881,02 713,45 988,79 781, ,56 8, ,33 918, ,10 987, , , , , , , , ,93 18, , , , , , , , , , ,80 Standard heat output at 75 / 65 / 20 C ( T K), Φ=Φ S 14 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
11 KRP91 Natural convection s and heat outputs Height 200 mm (depth mm) Version KRP91 KRP91 KRP91 Depth T Exponent n [ ] 1,52 1,45 1,46 per piece [EUR/pc.] 116,05 151,34 163,35 per metre [EUR/m] Length L Ribbed convector length Lribb T [K] without linear Φ [watts] ,53 LR: Aluminium linear, natural colour anodised (standard) with linear 264,45 289,58 380, 332,96 446,61 376,35 512,73 419,73 578,84 463,11 644,95 6,49 711,06 549,88 777,18 593,26 843,29 636,64 909,40 680,02 975,51 723, ,63 766, ,74 810, ,85 853, ,96 896,94 16,08 940, ,19 983, , without linear Φ [watts] ,47 with linear 320,12 375,81 471,46 431,93 551,49 488,05 631,52 544,16 711,55 600,28 791,58 656,40 871,61 712,52 951,64 768, ,67 824, ,70 880, ,73 936, ,76 993, , , , , , , , , , , ,94 Ribbed convector length = length floor pan mm, for length > 00 mm: length floor pan mm without linear Φ [watts] , with linear 332,13 386,85 495,48 4,73 578,51 498,60 661,55 554,48 744,58 610,35 827,61 666,23 910,64 722,10 993,68 777, ,71 833, ,74 889,73 12,77 945, , , , , , , , , , , , , ,00 Ascotherm eco KRP91 Standard heat output at 75 / 65 / 20 C ( T K), Φ=Φ S s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 15
12 KRP91 Natural convection s and heat outputs Height 200 mm (depth mm) Ascotherm eco KRP91 Version KRP91 KRP91 KRP91 Depth T Exponent n [ ] 1,46 1,46 1,48 per piece [EUR/pc.] 190,57 223,23 234,40 per metre [EUR/m] Length L Ribbed convector length Lribb T [K] without linear Φ [watts] ,37 LR: Aluminium linear, natural colour anodised (standard) with linear 362,62 0,94 553,19 478,53 643,85 536,13 734, 593,72 825,16 651,31 915,81 708, ,47 766, 1097,12 824, ,78 881, ,43 939, ,09 996, , ,46 15, , , , , , , , ,02 13, 2003,67 without linear Φ [watts] ,27 with linear 4,69 1, 647,92 571,07 754,09 640,64 860,27 710,20 966,44 779, ,61 849, ,78 918, ,96 988, , , , 1127, , , , , , , , , , , , , , , ,68 Ribbed convector length = length floor pan mm, for length > 00 mm: length floor pan mm without linear Φ [watts] ,81 with linear 444,15 521,21 678,55 592,91 789,59 664,62 900,63 736, ,66 808, ,70 879, ,74 951, , , , , , , , , ,93 19, , , , , , , , , , , ,15 Standard heat output at 75 / 65 / 20 C ( T K), Φ=Φ S 16 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
13 Product details The new connection sets with factory preset k V valves Connection sets for the Ascotherm eco It is recommended that the Ascotherm eco be fitted with preset k v connection sets (see accessories range). On request, the installation can be done at the factory. The Ascotherm eco units are fitted with preset connection sets depending on the heating or cooling capacity. Ascotherm eco units can also be fitted with the fine-adjusting valve. The adjustable valve insert permits reproducible settings of low water flow rates. The setting values can be taken from the diagram. Control curves for valve inserts Standard valve insert V5K S Presetting 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,56 8 k vs value up to 0,16 0,21 0,24 0, 0,34 0,41 0,44 0,54 0,65 0,82 0,98 1,11 1,23 1,33 1,43 Pressure loss in mbar ,5 2,5 3,5 4,5 5,5 6,5 7,5 7 8 Product details Water flow in kg/h s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 65
14 Product details The new connection sets with factory preset k V valves Valve performance limits of valve inserts for the Ascotherm eco connection sets Please note the valve performance limits in relation to the system parameters Standard valve insert V5K S Product details Presetting k vs value 1 0,16 1,5 0,21 2 0,24 2,5 0, 3 0,34 3,5 0,41 4 0,44 4,5 0,54 5 0,65 5,5 0,82 6 0,98 6,5 1,11 7 1,23 7,5 1,33 8 1,43 Δp [mbar] Temperature difference ΔT [K] s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
15 Product details The new connection sets with factory preset k V valves Fine-adjusting valve insert V5K F Presetting 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,56 8 k vs value up to 0,06 0,06 0,07 0,07 0,08 0,09 0,1 0,11 0,12 0,15 0,17 0,21 0,25 0,37 0,5 Pressure loss in mbar Product details ,5 2,5 3,5 4,5 5,5 6,5 7, Water flow in kg/h s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 67
16 Product details The new connection sets with factory preset k V valves Valve performance limits of valve inserts for the Ascotherm eco connection sets Please note the valve performance limits in relation to the system parameters Fine-adjusting valve insert V5K F Product details Presetting k vs value 1 0,06 1,5 0,06 2 0,07 2,5 0,07 3 0,08 3,5 0,09 4 0,10 4,5 0,11 5 0,12 5,5 0,15 6 0,17 6,5 0,21 7 0,25 7,5 0,37 8 0, Δp [mbar] Temperature difference ΔT [K] s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
17 Product details The new connection sets with factory preset k V valves Factory k V presetting of the valves KRP91 H T L Preset k V values ,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 12 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 2,5 10 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 17 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5 5,5* 5,5* 2,5 5,5* 5,5* 2,5 2,5 2,5 2, ,5* 5,5* 5,5* 5,5* 5,5* 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 4,5 22 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 4,5 4,5 20 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,5 4,5 27 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 00 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 32 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 2,5 2,5 2,5 2,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 5,5* 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 6,0 37 5,5* 2,5 2,5 2,5 2,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 6, ,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 6,0 6,0 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 6,0 6,0 40 2,5 2,5 2,5 2,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 4,5 6,0 2,5 4,5 4,5 4,5 6,0 6,0 47 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 4,5 6,0 4,5 4,5 4,5 4,5 6,0 6,0 00 2,5 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 2,5 4,5 4,5 4,5 6,0 6,0 4,5 4,5 4,5 6,0 6,0 6,0 * Fine-adjusting valve Dimensioning: Heat outputs at 70 / 55 / 20 C, Pressure loss across the valve 100 mbar Product details s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 69
18 Product details The new connection sets with factory preset k V valves Factory k V presetting of the valves KRN92 H T L Preset k V values ,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 12 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 10 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 17 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 5,5* 2,5 2, ,5* 5,5* 5,5* 5,5 5,5 5,5 5,5* 5,5* 5,5* 5,5* 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 22 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 20 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 27 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 00 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 32 5,5* 5,5* 5,5* 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 4,5 4,5 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 2,5 4,5 5,5* 5,5* 2,5 2,5 4,5 4,5 37 5,5* 5,5* 2,5 2,5 2,5 2,5 5,5* 5,5* 2,5 2,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4, ,5* 5,5* 2,5 2,5 2,5 4,5 5,5* 5,5* 2,5 2,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 40 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 2,5 2,5 4,5 4,5 4,5 47 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 5,5* 2,5 4,5 4,5 4,5 2,5 2,5 2,5 4,5 4,5 4,5 Product details 00 5,5* 5,5* 2,5 4,5 4,5 4,5 5,5* 2,5 2,5 4,5 4,5 4,5 2,5 2,5 4,5 4,5 4,5 4,5 * Fine-adjusting valve Dimensioning: Heat outputs at 70 / 55 / 20 C, Pressure loss across the valve 100 mbar 70 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
19 Product details The new connection sets with factory preset k V valves Factory k V presetting of the valves KRN81 H 110 T L Preset k V values 12 2,5 2,5 2,5 2,5 4,5 10 2,5 2,5 2,5 2,5 4,5 17 2,5 2,5 4,5 4,5 4, ,5 4,5 4,5 4, ,5 4,5 4,5 4, ,5 4, , , , Dimensioning: Heat outputs at 70 / 55 / 20 C, Pressure loss across the valve 100 mbar Product details s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 71
20 Product details The new connection sets with factory preset k V valves Factory k V presetting of the valves KC 281 H T L Preset k V values * 0* 0* 0* 27 0* 0* 0* 0* Note: On the KC2 81, the valve inserts are preset in relation to the cooling capacity, since the water flow rate required for cooling is usually higher than for heating. Dimensioning: Cooling capacities at 16 / 18 / 27 C, Pressure loss across the valve 100 mbar KC 481 H T L Preset k V values * 0* 0* 0* 27 0* 0* 0* 0* Product details Dimensioning: Cooling capacities at 16 / 18 / 27 C, Pressure loss across the valve 100 mbar KC 481 H T L Preset k V values 12 4,5 4,5 4,5 4, * 8 0* Dimensioning: Heat outputs at 70 / 55 / 20 C, Pressure loss across the valve 100 mbar * Wherever kv preset values are stated as 0, the maximum convector outputs are above the valve performance limits for the indicated system parameters. In this case, it is necessary to check whether the dimensioned output is within the valve performance limits. See data under valve performance limits. 72 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
21 Arbonia Individual Special versions Angled version Available for all versions and for empty pan Angle can be between and 320 Please provide a dimensional drawing or template with the order. Feasibility depends on engineering review Radiator must still be transportable Dimensional drawing Ordering code BES Floor pan Additional price / bevel cut Linear Roll-up WA T L2 L1 T W A L2 90 Single bevel L ) 49,00 46,00 164,00 L2 T WA L1 L2 T WA α L1 α 1) Characteristic 77 for bevel cut at both ends L1, L2: Length of the limbs, measured on the wall α: Angle T: Depth floor pan WA: Wall spacing Ascotherm eco Individual s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 73
22 R Ascotherm eco Arbonia Individual Special versions Curved version Available for KRP91 (other versions on request) Bending radius R: at least 1000 mm Please provide a dimensional drawing or template with the order. Feasibility depends on engineering review Radiator must still be transportable Dimensional drawing Ordering code BES Additional price per radiator L R T WA Inside radius 70 On request L WA T Ascotherm eco Individual L: Streched length R: Bending radius (wall radius) T: Depth floor pan WA: Wall spacing Outside radius 74 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
23 Arbonia Individual Special versions Column section version Available for all versions and for empty pan Please provide a dimensional drawing or template with the order. Feasibility depends on engineering review Radiator must still be transportable Dimensional drawing Column section according to drawing column section in floor pan column section in linear column section in roll-up Ordering code IBESI Additional price per column section Floor pan Linear Roll-up Ød A 75 On request On request On request Ascotherm eco Individual C Ød C Ød A A C C C C A B A B A B d: Diameter A: Inset dimension for length B: Edge dimension C: Inset dimension for depth s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 75
24 Arbonia Individual Special versions Version with impact sound insulation Without impact sound insulation With impact sound insulation Description Standard version Ordering code IEBTI Additional price per metre TS1 39,00 Impact sound insulation 4 mm Coupled Ascotherm radiators are supplied individually Connection material (flexible connection hoses etc. available as accessory) Only for versions KRP91 (not for H 1 and H 200), KRN92, KRN81 On version KRN81 (max. up to 4 motors) without Connection system Connection on the same side from the left Description Radiator position 2 repeats when coupling more than 3 radiators Please provide a drawing with the order Initial radiator 1 Middle radiator 2 Final radiator 3 Ordering code KHP Sequence of coupled radiatorsδ(enter in column "Special characteristics") Additional price per radiator Ascotherm eco Individual Connection on the same side from the right Radiator position 2 repeats when coupling more than 3 radiators Please provide a drawing with the order Final radiator 3 Middle radiator 2 Initial radiator ,00 76 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
25 Arbonia Individual Special versions Air connection with air connection valve Number of air connections LAZ Length Description and dimensional drawings 1 00 mm Standard: 1 air connection, incl. air valve Additional air connections possible (max. number and location on request) Air connections are distributed evenly (to the extent technically possible) The exact positioning of the air connections can be seen in the drawing Air connection arrangement LAP 1) Height H Connection size LAG Additional price per additional connection 110, 1, ,00 1, , , ,00 2 > 00 mm Standard: 2 air connections, incl. air valves Additional air connections possible (max. number and location on request) Air connections are distributed evenly (to the extent technically possible) The exact positioning of the air connections can be seen in the drawing Special connections - Version per drawing - LAP = SON No clear assignment of positions, since floor pan joined at the factory 110, 1, ,00 1, , , ,00 On request 1) The positioning of the air connections is affected slightly by the arrangement of the cross bracing in the floor pan, example: connection F (room side, centred) = "approx. centred" The exact dimensions/positions can be seen in the drawing and need to be approved by the customer. Number and positions of the air connections L/2 ±75 L/2 ±75 L 00 L/4 ±1 L/4 ±1 L > 00 Ascotherm eco Individual s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 77
26 Arbonia Individual Special versions Additional special versions Pressure version Description High-pressure version Characteristic Ordering code Additional price per radiator 16 bar (1600 kpa) DRU % Special versions Special length for heating 1) > 1000 mm (KRP91 and KRN92) > 12 mm possible (KRN81) Special length for heating and cooling 1) BES SBL Next-larger standard length > 12 mm possible BES SBL On request Extra-short length (smaller than smallest standard length) 600 mm - < 1000 mm possible (KRP91 and KRN92) 1000 mm - < 12 possible (KRN81) 8 mm - < 12 mm possible (KC281) 10 mm - < 12 mm possible (KC481) BES SBL On request Special depth acc. to drawing 2) BES SBT On request Special height according to drawing 3) BES SBH On request Fixing Fixing with special bracket (in case of high soil structure) On request Special finish 1) Provide exact length 2) Provide exact depth 3) Provide exact height Finished in special colour (no RAL colour) Aluminium linear / aluminium roll-up AUS SF On request Floor pan and register FAR1 99 On request Finished in other RAL colour (standard is RAL 7016) Floor pan and register FAR1 SF + % Ascotherm eco Individual 78 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
27 Ascotherm eco Individual On request, accessory components, available factory-installed Available on request Edge bar Description Anodised in natural colour ELO = Anodised in natural colour RDL ELO Colour anodised BRO = Anodised in bronze finish MES = Anodised in brass finish DKS = Anodised in dark silver finish SWZ = Anodised in black finish EDS = Anodised in stainless steel finish Paint finish FAR1 = Edge bar finished as floor pan/register RDL FAR1 RDL Characteristic Ordering code BRO MES DKS SWZ EDS Additional price per metre 11,00 11,00 11,00 11,00 11,00 FAR2 = Edge bar finished as top RDL FAR2 49,00 Air-intake filter For KRN81 air-intake filter PPI dark 90 x 3 mm FVL FV 8,00 For KC281 and KC481 air -ntake filter PPI dark 140 x 3 mm FVL FV 9,00 Accessory components, factory-installed Description Characteristic Ordering code Additional price per radiator Installation Connection set, straight form with preset k v valve Consisting of: Valve base with factory preset kv valve DN 15, both sides 3 / 4 external thread with euro taper M x 1,5 nickel-plated, protective cap Return fitting with shut-off DN 15, both sides 3 / 4 external thread with euro taper nickel-plated Threaded fitting attached only hand-tight For all KRN, KRP91 and KC281 with connection 11 or 33 For KC481 with connection 11 or 33 VRS VRS 44,00 VRS VRS 88,00 Connection set, angled version with preset k v valve Consisting of: Valve base with factory preset kv valve DN 15, both sides 3 / 4 external thread with euro taper M x 1,5 nickel-plated, protective cap Return fitting with shut-off DN 15, both sides 3 / 4 external thread with euro taper nickel-plated Threaded fitting attached only hand-tight For KC281 with connection BB or DD For KC481 with connection BB or DD VRS VRS 44,00 VRS VRS 88,00 Connection set, angled version with preset k v valve, connection arrangement 66/88 Consisting of: Valve base with factory preset kv valve DN 15, outlet 3 / 4 external thread with euro taper, inlet 1 / 2 internal thread M x 1,5 nickel-plated, protective cap Return fitting with shut-off DN 15, both sides 3 / 4 external thread with euro taper nickel-plated Threaded fitting attached only hand-tight For KRP91, KRN92 and KRN81 VRS VRS 44,00 Ascotherm eco Individual Thermoelectric actuator 2 V AC Factory-installed Only in conjunction with VRS For KRP91 and KRN92 STT STT 29,00 Thermoelectric actuator 24 V DC Factory-installed and with controller board wired Only in conjunction with VRS For KRN81 and KC281 STT STT 92,00 For KC481 STT STT 184,00 KNX plugin card (for KRN81, KC281 and KC481) for installation in the Ascotherm eco control board to connect to KNX networks, only 1 per convector group is needed (up to 6 convectors) For KRN81, KC281 and KC481 GLT KNX 146,00 s without value-added tax. Technical specifications subject to change.s and Technology 2015-N 79
28 Accessories Empty floor pan Ascotherm eco empty floor pan For the... Arbonia offers an Ascotherm empty floor pan in its accessories range. The range available (H / B / T) and the special or extra-short empty floor pan lengths are listed at the individual versions. Accessories Description Product code Empty floor pan ZA0108 Characteristic Dimensions Heights: 92, 110, 120, 1, 1, 155, 200 mm Depths: 185, 210, 260, 310, 3, 360, 400 mm Lengths variable: mm Finish Standard in anthracite grey (RAL 7016 matt finish) Top version Standard in aluminium, anodised in natural colour Material Galvanised sheet steel, colour-coated Dimensions Ordering code Product Version Ordering code 3 1) Dimensions HOE and MT need to be stated with the order (for description, see chapter "General information") s for other colours, see chapter "Ascotherm top s" and "Special versions". per piece [EUR/pc.] per metre without [EUR/m] per metre with [EUR/m] per metre without [EUR/m] ZA , 89,04 179,96 179, ) 111, 100,17 195,82 195, , 111, 219,93 219, , 122,43 254,68 254, , 133,56 279,98 279, , 144,69 2,03 2, ZA , 100,17 191,09 191, ) 111, 111, 206,95 206, , 122,43 231,06 231, , 133,56 265,81 265, , 144,69 291,11 291, , 155,82 313,16 313, ZA0108 1) 111, 100,17 271,38 271, , 111, 282,62 282, , 122,43 296,68 296, , 133,56 191,09 191, , 144,69 206,95 206, , 155,82 231,06 231, ZA0108 1) 111, 139,13 265,81 265, , 144,70 291,11 291, , 1,26 313,16 313, ZA , 111, 202,22 202, ) 111, 122,43 218,08 218, , 133,56 2,19 2, , 144,69 276,94 276, , 155,82 2,24 2, , 166,95 324,29 324, ZA , 1,26 282,51 282,51 3 1) 111, 155,83 293,75 293, , 161,40 7,82 7, ZA , 122,43 213,35 213, ) 111, 133,56 229,21 229, , 144,69 253,32 253, , 155,82 288,07 288, , 166,95 313,37 313, , 178,08 335, 335, 80 s and Technology 2015-N s without value-added tax. Technical specifications subject to change.
Ascotherm eco KC481 Heating and cooling in 4-conductor system
KC481 Heating and cooling in 4-conductor system Tender specification, range available and sizes Tender specification Version KC481 heating and cooling in 4-conductor system Ready-to-install floor pans
More informationMikrotherm F. Manual Radiator Valves With presetting
Mikrotherm F Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Mikrotherm F The Mikrotherm F manual radiator valve is used in warm water pump heating
More informationV2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION
V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION PRODUCT DATA Application 011 Angle to DIN Angle to NF Straight to DIN Straight to NF Thermostatic radiator valve bodies (TRV
More informationCNVA TECHNICAL DOCUMENTATION. Active floor convector. Contents
CNVA Active floor convector Contents General description... 2 Advantages/Customer benefits... 2 Operation... 2 Description of the equipment... 3 Construction and Dimensions... 4 Accessories... 7 Connections...
More informationSLOT DIFFUSERS, ROUND DUCT DIFFUSERS
SLOT DIFFUSERS, ROUND DUCT DIFFUSERS Slot diffusers LD-3, LD-4, LD-5 LD-3 LD-4 LD-5 SLOT DIFFUSERS Application: Slot diffusers are designed for air supply in rooms with floor to ceiling heights of 2.5
More informationCOMPACT XPANEL RADIATORS XCOMPACT
XPANEL RADIATORS XCOMPACT COMPACT The Compact 4-connector profile radiator is fitted with 4 x ½ BSP connections at the side. The vertical profile is 33 mm and this in combination with the convection fins
More informationV2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE
V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE PRODUCT DATA Angle to EN215 (D) 011 Straight to EN215 (D) Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the
More informationRTL. Floor Heating Controller Return temperature limiter with and without presetting
RTL Floor Heating Controller Return temperature limiter with and without presetting IMI HEIMEIER / Floor Heating Control / RTL RTL Among other things, the return temperature limiter RTL is used to limit
More informationceiling swirl diffuser DQJ
ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...
More informationCONVECTORS & HEATING PANELS
284 product description CONVECTORS & HEATING PANELS Connections: 2 x internal thread G 1/2, welded-in for supply and return. Vent and drain plugs (or dummy plug) are factory sealed and are fi tted according
More informationHudevad LK. Technical datasheet
Technical datasheet Key benefits Kundenedfald Grøn energi Swedish high quality steel Highly robust and durable Fully welded solution No removable parts, making it highly durable and completely tamper-proof
More informationV2000Kx KV type TRV Body
V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE PRODUCT DATA Angle to DIN Straight to DIN 011 Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply
More informationRegutec F. Return Lockshield Radiator lockshield
Regutec F Return Lockshield Radiator lockshield IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regutec F Regutec F The Regutec lockshield is used in pumped warm water heating and air conditioning
More informationTESI STEEL MULTI COLUMN RADIATORS COMMERCIAL HEATING SOLUTIONS
TESI COMMERCIAL HEATING SOLUTIONS 2 A brand of IRSAP, Italy s leading manufacturer of design led radiators. /6 04.09.18 Units 13-14 Charlwoods Road East Grinstead, West Sussex, RH19 2HU www.clyderadiators.co.uk
More informationV2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE
V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE PRODUCT DATA 1/2 Angle to DIN 1/2 1/2 Straight to DIN 1/2 011 Application Thermostatic radiator valve bodies (TRV bodies) are fitted
More informationVERTICAL RADIATOR. Technical data. Profile radiator. Connections 4 x G 1/2 I.G. Test positive pressure 13 bar
Technical data 45 VERTICAL Profile radiator Connections 4 x G 1/2 I.G 13 bar Test positive pressure 13 bar 10 bar max. Max. positive operating pressure e 10 bar max. Max. operating temperature 110 10 C
More informationWGA Long throw nozzle grille
Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...
More informationHigh capacity valve body, type RA-G
Application The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). The
More informationHudevad Standard. Technical datasheet
Technical datasheet Key benefits $ Swedish high quality steel Highly robust and durable Pressure tested at high pressure Approved for district heating Historical Kundenedfald Highly flexible in size Huge
More informationPLAN COMPACT VENTIL PANEL RADIATORS PLAN COMPACT VENTIL
PANEL RADIATORS The Plan Compact Ventil combines the timeless beautiful elegance of a perfectly flat front with the advantages of an integrated valve connection. It has a perfect panel front, so that from
More informationTemperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)
Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description Controller closes on rising temperature. The controllers are: - Type-tested acc. to EN 14597
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades
More informationV2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE
V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE PRODUCT DATA Application 1/2 011 Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply or return of radiators or heat
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation
More informationSlot diffusers, Round duct diffusers. IMP Klima
, Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING
More informationRADIK RC. energy saving panel radiators RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC RC
RC RC RC RC RC RADIK RC RC energy saving panel radiators RC RC RC RC RC RC 2/2016 Radik RC for your comfort We need a radiant heat component for our own satisfaction and a pleasant feeling of thermal
More informationHudevad Integral. Technical datasheet
Technical datasheet Key benefits $ Sleek flat front Minimalistic design Pressure tested at high pressure Approved for district heating Historical Kundenedfald Highly flexible in size Huge range of dimensions
More informationVentilation grille Model AL
Ventilation grille AL Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationCeiling induction diffuser DISA-300
Ceiling induction diffuser DISA-300 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationDynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control
Dynacon Automatic Flow Control Floor Heating Manifolds Floor heating manifold with automatic flow control IMI HEIMEIER / Floor Heating Control / Dynacon Dynacon Dynacon adjusts the flow rate in the individual
More informationT6-PLAN CENTRALLY CONNECTED RADIATOR.
50 T6-PLAN CENTRALLY CONNECTED RADIATOR Technical data T6-PLAN CENTRALLY CONNECTED RADIATOR. Connections 4 x internal thread G 1/2 and 2 x external thread G 3/4 bottom centre 10 bar max. Max. positive
More informationGEZE TS 3000 V / TS Product features
GEZE TS 5000 L-E-ISM Overhead door closer for double-leaf doors, with integrated mechanical closing sequence control and electromechanical hold-open on both sides, standard mounting on opposite hinge side
More informationVentilation Grille PA
Ventilation grille PA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationCeiling induction diffuser DISA-601
Ceiling induction diffuser DISA-601 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationSwirl Diffuser Model DQF
Swirl Diffuser Model DQF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationADDITIONS, VALVES & ELEMENTS 76.
ADDITIONS, VALVES & ELEMENTS 76. REGENT Lead 114.00 136.80 Satin Chrome 114.00 136.80 MONARCH Polished Chrome 149.00 178.80 Satin Chrome 160.00 192.00 Bright Nickel 166.00 199.20 Satin Nickel 175.00 210.00
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationHudevad Standard Hygiene
Technical datasheet Key benefits Historical Kundenedfald Grøn energi Swedish high quality steel Highly robust and durable Rengøring Panels spaced for easy access Fast and easy cleaning between panels Highly
More information4-way Distribution Valve
4-way Distribution Valve for one- and two-pipe systems Product specification sheet Application 4-way distribution valves are used to connect supply and return of a radiator to the corresponding pipes of
More informationCeiling diffuser 4DE
Ceiling diffuser 4DE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...
More informationTechnote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.
Page of 7 Application control unit, in conjunction with the associated hydraulic set provides a complete pressure independent balancing and control group for efficient and effective individual room or
More informationCeiling Slot Diffuser Model DSX
Ceiling Slot Diffuser Model DSX Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationFlow-compensated temperature controller AVTQ DN 15
Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers
More informationRound duct diffuser DBB-RR
Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationButterfly valves PN 16
s 4 119 ACVATIX TM Butterfly valves PN 16 VKF42.. Gray cast iron or nodular cast iron valve body DN 50...600 k vs 65...37,000 m 3 /h For fitting with PN 16 counter-flanges to ISO 7005 Tight-closing in
More informationCAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1
X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air
More informationThe Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation
The is quiet even at high outputs, making it a discreet and effective heater for almost any situation A selection of grilles and finishes are available. Installation is simple and hassle-free due to the
More informationNozzle Jet Diffuser Model DSA
Nozzle Jet Diffuser Model DSA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Application...
More informationAir diffuser system Model AUDIX -AW
Air diffuser system Model AUDIX -AW Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationButterfly valves PN6, PN10, PN16
4 136 Butterfly valves PN6, PN10, PN16 VKF46... Butterfly valves for fitting between counter-flanges Nominal pressures PN6, PN10, PN16 For fitting between PN6, PN10 or PN16 counter-flanges to ISO 7005
More informationWARMTH FROM THE FLOOR. ISAN Radiátory is a producer of floor convectors ISAN OPLFLEX.
C A T A L O G U E 0 0 6 / 0 0 7 F L O O R C O N V E C T O R S ISAN Radiátory is a producer of floor convectors ISAN OPLFLEX. Convectors are recommended under glass areas into the different buildings. In
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single
More informationWALL VENTILATION GRILLES CBP
WALL VENTILATION GRILLES CBP 01.10-01 CBP WALL VENTILATION GRILLES Description Designed for ventilation and air-conditioning installations, where control of air flow and direction of the air is required.
More informationT6-PLAN HYGIENE CENTRALLY CONNECTED RADIATOR.
Technical data 59 T6-PLAN HYGIENE CENTRALLY CONNECTED RADIATOR. T6 PLAN HYGIENE Connections 4 x internal thread G 1/2 and 2 x external thread G 3/4 bottom centre 13 bar 10 bar max. max. Test positive pressure
More informationUTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management
Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and
More informationC O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CD SERIES CD SERIES LINEAR SLOT DIFFUSERS QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman Moducel
More informationZaros Aluminium radiators
4 Zaros VERTICAL (ZAROS V5, ZAROS V100) ZAROS V5 ZAROS V100 return supply ref. nr. 1181000000099 price 14 Fittings, see p. 19 TYPES Vertical: Zaros V5 and Zaros V100 (depth) COLOURS Standard colour S00
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV
More informationHudevad Flat Front. Technical datasheet
Technical datasheet Key benefits $ Completely sealed casing Clean and tamper-proof design Pressure tested at high pressure Approved for district heating Historical Kundenedfald Highly flexible in size
More informationaplano plus Distinctively elegant vertical radiators
aplano plus Distinctively elegant vertical radiators Aplano Plus Dimensions Product code: APP C 121 90 air vent G 1/8 2.5 25 45 70 95 H 300 410 520 630 740 8 C 160 270 380 490 600 710 100 70 6 88 min.
More informationMTU Friedrichshafen. MTU Project No. - ENGINE DATA - Printout: (y-m-d) Sheet 1
Printout: (y-m-d) 2006-08-09 Sheet 1 0. DATA-RELEVANT ENGINE DESIGN CONFIGURATION 1 Fuel-consumption optimized X 2 Exhaust-emissions optimized (limit values see Exhaust Emissions, Chapter 21) 47 "TA-Luft"
More informationVentiduct nozzle ducts
Ventiduct nozzle ducts About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement
More informationCeiling Swirl Diffuser DQJ
Ceiling Swirl Diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de contents Description...3 Advantages...
More informationTechnical information Thermostatic radiator valves
The Oventrop Quality Management System is certified to DIN-EN-ISO 900 Technical information Thermostatic radiator valves Function: Oventrop thermostatic radiator valves are proportional regulators working
More informationStradaflair. Strada Trench Convectors. Strada Flat Panel Range. Strada Radiant Skirting. Strada Heated & Chilled Ceilings. Strada Electrical Products
Other Strada Products Strada Trench Convectors 2No. Models, Hot Water and Electric Strada Flat Panel Range Aluminium & Steel for ceiling & wall mounting Strada irad Stradafloor Strada Hi-Rad Strada Hi-Rad
More informationPURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS
Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with
More informationMaximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment
Maximum Protection in Filter Systems CGF/CGG GEA Ceiling Air Outlets Data & Facts GEA Heat Exchangers / GEA Air Treatment Table of Contents Technical Description... 3 Application and Components... 3 Components...
More informationTECHNICAL INFORMATION HENRAD PREMIUM ECO RADIATOR YOUR IDEAL HEATING SOLUTION
ECO Technical documentation 2017 Export TECHNICAL INFORMATION HENRAD PREMIUM ECO RADIATOR YOUR IDEAL HEATING SOLUTION ECO RANGE WHY Green heat? WE CAN NO LONGER DENY IT: THE ENVIRONMENT IS SUFFERING BECAUSE
More informationFlat Fronted. Panel radiators. General Information 2 Type Type 21 (p+) 5 Type Type
Flat Fronted Panel radiators Contents Page General Information 2 Type 11 3-4 Type 21 (p+) 5 Type 22 6-7 Type 20 8-9 Engineering Data Sheet 828/1 November 2014 www.clyderadiators.co.uk General information
More informationCompact Grille Model KG
Compact grille KG Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...3
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationC O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CE SERIES CE SERIES LINEAR SLOT DIFFUSERS CE SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman
More informationCAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1
X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered
More informationAVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.
Data sheet Flow and temperature controller with / without integrated control valve (PN 25) AVQT - flow and temperature controller AVQMT - flow and temperature controller with integrated control valve Description
More informationActive Chilled Beams
T 2.4/3/EN/1 Active Chilled Beams Type DID00B TROX GmbH Telephone +49/2 45/2 02-0 Telefax +49/2 45/202-25 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn www.troxtechnik.com Contents Description
More informationHudevad Integral Hygiene
Technical datasheet Key benefits Historical Kundenedfald Grøn energi Swedish high quality steel Highly robust and durable Healthcare Public Sikkerhed Energi C Rengøring Panels spaced for easy access Fast
More information3-Port Seat Valves with Male Thread, PN 16
4 463 3-Port Seat Valves with Male Thread, PN 16 VXG41 Use Media Bronze CC491K (Rg5) valve body DN 15DN 50 k vs 1640 m 3 /h Flat sealing connections with external thread G B to ISO 228/1 Sets of ALG 3
More informationSENTRY LST. Convector Heating. General Information 1 Technical Data 2 Dimensions 2 Emission Rates 3-6 Connection Configuration 7 Installation 8-9
SENTRY LST Convector Heating Contents Page General Information 1 Technical Data 2 Dimensions 2 Emission Rates 3-6 Connection Configuration 7 Installation 8-9 Engineering Data Sheet 811/1 January 2010 www.clyderadiators.co.uk
More informationValve bodies type RA-N with integrated presetting
Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000
More informationKey Switches J J Key Switch S/T.. M 28 KABA. Key Switch MS 42 P/RS 42 P J J
Key Switches SURVEY Key Switches S/T.. M 28 KABA S/T.. M 28 KABA Style MT 28 square S/T.. M 28 KABA Style MT 42/RT 42 S/T.. M 28 KABA Style EK 42 KABA Key Switch S/T.. M 28 KABA J. 8. 3 - J. 8. 5 MS 42
More informationLined Butterfly Valve Pfeiffer Type BR 10a
Lined Butterfly Valve Pfeiffer Type BR 10a Application Tight closing, double eccentric butterfly valve with PTFE lining for process engineering and plants with industrial requirements, especially suitable
More informationConvectors & heating panels
Convectors & heating panels Content 247 VONARIS solitary finished radiator 1 VONARIS VHV VONARIS VSV Product description 248 Model overview / VHV connection dimensions 249 WVO design 250 Model overview
More informationGrilles Linear Grilles
1/1.1/B/2 Grilles Linear Grilles Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 763051 www.troxuk.co.uk e-mail: trox@troxuk.co.uk Contents Description
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,
More informationCAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)
X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered
More informationInternorm Stil. Colour: White aluminium, similar to RAL 9006 and anthracite grey, similar to RAL Protection class: IP 20/DIN EN 60529
Internorm Stil Detailed product information can be found on www.bopla.de - 2 heights - 3 widths - 5 depths - With or without integrated ventilation - Tower enclosure in 2 sizes - Internorm Stil is based
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationCAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1
X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air
More information3-port seat valves, external thread, PN16
4 464 3-port seat valves, external thread, PN6 VXG44.. ronze CC49K (Rg5) valve body DN 5..DN 40 k vs 0.25..25 m 3 /h Flat sealing connections with external thread G to ISO 228- Sets of ALG..3 screwed fittings
More informationMINI CANAL. Discreet power
MINI CANAL 2015.UK MINI CANAL Discreet power For spaces with large windows, glazed façades, conservatories, display windows and offices. From a depth of 9 cm, Mini Canal is the perfect solution for multi
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air
More informationSelf-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points from 0 to 250 C G ½ to G or DN 5 to DN
More informationthree-way mixing valve
three-way mixing valve with or without presetting, for heating and cooling systems. Pressurisation & Water Quality alancing & Control Thermostatic Control engineering avantage Three-way mixing valve, with
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey
More informationSlot diffusers for ceiling installation
X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,
More informationOverview of types. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems
Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight
More informationParticle Filter Box FKU
Particle Filter Box FKU Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More information