PRIMADET non-electric delay detonators MS Primadet - millisecond series
|
|
- Margery Phelps
- 6 years ago
- Views:
Transcription
1 PRIMADET non-electric delay detonators MS Primadet - millisecond series function MS Primadet series detonators are used as downlines in opencast mining and quarry operations where point initiation is desired down the hole. The unit consists of a precise detonator assembled on a sealed length of shock tube with a J-hook at the other end. description The MS Primadet non-electric delay detonators, whose lengths and delay times are suited for use in surface blasting, are factory-assembled units with the following main components: Shock tube to transmit a signal to the delay cap. The shock tube is a 3mm diameter plastic laminated tube coated inside with a thin layer of HMX / Aluminium dust, which reliably transmits a low energy signal at approximately 2000m/s from one point to another. Due to the shock tube construction and inner Surlyn tube, the low energy signal will propagate through most sharp bends, knots and kinks that may occur in the shock tube. The outer surface of the tube remains intact during and after functioning. The distinguishable tough, orange outer jacket gives excellent abrasive, oil resistant and tensile properties. A precise in-hole detonator containing integral delay elements, anti-static protection and other patented safety devices. This detonator will initiate all compatible cast boosters and cap sensitive explosives. A colour-coded J hook is an inert fitting at the initiation end of the MS Primadet, for quick and reliable connection to Primacord detonating cord. Tape used to bind each unit in a coil, facilitating easy deployment and a reduced chance of tangling. A colour delay tag to indicate the nominal delay time of the detonators.
2 advantages simple/flexible accurate reliable The MS Primadet non-electric blast initiation system is factory assembled to the required length and delay time. They can readily and simply be connected to accommodate both basic and complex blast initiation requirements. The MS Primadet non-electric delay detonators are manufactured using the most modern robotic production techniques resulting in extreme accuracy and precision. The MS Primadet non-electric blast initiation system is factory assembled-to-order under stringent quality specifications. Continued technological advancement has resulted in patented design changes providing increased reliability, blast after blast. External layer (over-extruded plastic jacket of low density polyethylene) for abrasion resistance and UV protection Middle layer for tensile strength, elongation and chemical resistance Inner Layer (Surlyn) reliably holds the reactive mixture in place Primadet shocktube properties Tensile strength 18kg Elongation 320% Chemical resistance >24 hours at 70 C Fuel resistance Superior oil / diesel resistance Low reactive material No fumes / gasses Non-electric Immune to radio frequencies Initiation by means of a shock wave No fire risks Robust Will propagate through knots & kinks 2
3 cost-effective custom packaging The MS Primadet TM non-electric delay detonators, due to their reliability and sequential firing, provide improvements in blast results. Custom packaging densities are available on request. safe Cushion Disc* Wipes inside of shell of primary explosives. - Increases shock resistance. - Prevents instantaneous detonation. Sealer Element & Sealer Crimp Maintains constant pressure within detonator as main delay burns. - Improves timing due to consistent pressure within detonator chamber. Starter Element Ensures consistent ignition of less sensitive main delay. - Improves reliability and accuracy of unit. Delay Ignition Buffer* (DIB Screen) Prevents reverse propagation. - Flame from delay cannot initiate shocktube and second detonator. Prevents delay suck-out. - Pyrotechnic delay powder held in place within detonator shell. * Patents. primer assemblies MS Primadet series detonators are designed for use with all Trojan and equivalent cast boosters, cartridged explosives and most cap sensitive explosives, available in the market. The suppliers of these products should be consulted for compatibility. If cartridged explosives are being used as a primer, a hole of the correct length must be punched into the primer using a non-ferrous primer punch. Once the hole has been made, the MS Primadet in-hole detonator can be inserted into the cartridge. The shock tube lead can then be half-hitched around the cartridge, for extra security with regard to detonator pull-out. The primer is then inserted into the charge hole according to the mine standard. 3
4 Booster assemblies are typically connected as follows: If ANFO, cartridges or pumpable emulsion explosives are used, the MS Primadet in-hole detonators must be inserted as far as practically possible (bottom third of hole), according to the mine standard. important instructions Please note the following: All detonators (surface and in-hole) are subject to detonation caused by abuse such as impact, tampering and general misuse. Never attempt to disassemble any detonators due to the above reasons. The shock tube should not be cut or damaged as moisture or dirt entering the tube could cause misfires. Holes loaded with this product and awaiting firing should be guarded or barricaded to prevent unauthorised entry, as per mine standard. Never attach the starter initiator to the blast until the blast is completely hooked up and the blasting area cleared. Always store detonators and explosives separately. Keep accessories away from sparks, flames or any other sources of ignition. Excessive temperatures may result in spontaneous ignition of explosives and accessories. Store explosives and accessories according to the country rules & regulations. Ensure that all the MS Primadet downlines and outgoing trunkline leads are securely clipped to avoid misfires. Never use damaged MS Primadet units as this may result in misfires. After all the holes have been connected, do a thorough inspection of all the hook-ups, for proper connection. Shock tube will only be reliably initiated by detonating cords with core loads of 3.5g/m or higher ie. Detacord, E-Cord, SB Cord TM and Zapcord. Never trim ultrasonic seals from the shock tube, since the entrance of moisture and/or dirt into the tube may cause misfires. Primacord detonating cord to shock tube connections should always be made at right-angles. Grip the sealed end of the MS Primadet TM lead and push the J-hook towards the collar of the borehole. Do not allow slack in the shock tube going from the J-hook to the collar of the borehole. Always place detonating cord trunkline hook-ups in closed loops and use with cross-ties (boxed-in). Two paths of initiation will then be available for each shock tube connection. Never drive any vehicles over shocktube, as it may rupture or damage the tube, may cause misfires. packaging information Additional product lengths and packaging densities are available on request. Please contact your representative. 4
5 standard packaging MS Primadet TM A Pack B Pack Case dimensions (mm) 605 X 315X X 315 X 220 Product length (m) Units per case Units per case colour codes & labelling The MS Primadet J - hook connector blocks are colour coded according to delay times. Nominal delay (ms) Colour of block 350 Green 375 Black 400 Camphor green 500 Dark blue 525 Violet 600 Blue recommended storage, shelf life & transport MS Primadet - millisecond series Recommended storage 6 months (dry, well ventilated) Shelf life 24 months Transport: UN classification 1.1B UN number 0360 Zax number 355A warning and disclaimer All products and equipment manufactured and supplied by Sasol Dyno Nobel shall be used, handled, stored or transported according to the guidelines laid down by the relevant applicable legislation in that country. Explosive accessories should be secured in an explosive magazine. All or any part of the explosive accessories is dangerous and can cause injury or death. If you find any of these items, do not touch them. Instead, immediately report their location and description to the police. To the extent provided for in terms of section 61 of the Consumer Protection Act, 2008, Sasol Dyno Nobel shall not be liable for any damage, whatever its nature, including incidental, consequential and indirect damage caused to buyers or third parties, directly or indirectly arising from or relating to the supply, use or storage of the products and equipment arising after delivery unless caused by Sasol Dyno Nobel s wilful misconduct or gross negligence. *Trademarks are registered or applied marks are licensed to Sasol. 5 Sasol Dyno Nobel (A division of Sasol Chemical Industries Limited 1968/01/391/06) 15 Baker street Rosebank 2196 PO Box 5486 Johannesburg 2000, South Africa +27 (0) Rev 2 September 2013
PRIMADET non-electric delay detonators Dual StoperTM
PRIMADET non-electric delay detonators Dual StoperTM Dual DetTM EZ Stoper EZ Platinum trunklinetm function The Dual StoperTM non-electric blast initiation system is a precise, reliable and millisecond
More informationSafeStart hand held SafeStart Initiators (SI-1)
SafeStart hand held SafeStart Initiators (SI-1) function The hand held SafeStart Initiators (SI-1) is designed to fire a SafeStart instantaneous detonator from a distance of up to 1km away using standard
More informationSHORT DELAY NON-ELECTRIC DETONATORS
Bulgaria, 5300 Gabrovo, 1 Uspeh Str., office 3; phone/fax: +359 66 80 50 11; mobile: +359 888 693123 e-mail: tempus_link@abv.bg MS SHORT DELAY NON-ELECTRIC DETONATORS Product Description MS constitute
More informationNONEL EZ DET. Properties. Technical Information. Nonelectric Blast Initiation System. Your Partner with TOTAL BLASTING SOLUTION
NONE EZ DET Nonelectric Blast Initiation ystem Product Description Nonelectric Delay Detonator NONE EZDET units consist of a length of orange shock tube with a surface detonator attached to one end and
More informationORICA NEW ZEALAND WESTPORT - PRICE LIST
ORICA NEW ZEALAND WESTPORT - PRICE LIST MINING SERVICES 1 January 2018 Orica New Zealand Westport 1 January 2018 2 Price List Information Customers are advised that from the 1 January 2018 the revised
More informationKompensator External Low Voltage Heating Cable System
External Low Voltage Heating Cable System LOW VOLTAGE Installation Instructions General Information Kit Contents Qty Description 1 heating cable at pre-determined length Table of Contents General Information........................
More informationRoyex Gen II Rock breaking cartridge Technical data sheet
E T K E N T E K N O L O G I Royex Gen II Rock breaking cartridge Technical data sheet Etken Teknolgi Runsätravägen 5 123 63 Farsta, Sweden Tel: 08-94 10 70 www.royexsystem.com 1. Introduction The Royex
More informationINITIATING SYSTEMS ACCESSORIES RANGE
INITIATING SYSTEMS ACCESSORIES RANGE AUSTRALIA PACIFIC INDONESIA JULY 2016 Electric Exploders Ausdet Stinger SB10 Exploder SAP Code: XEXP10 A capacitor discharge exploder including rechargeable battery
More informationOPERATIONS MANUAL LEVER CHAIN HOIST
OPERATIONS MANUAL LEVER CHAIN HOIST IMPORTANT SAFETY INFORMATION Please read, understand and follow all safety information contained in these instructions prior to the use of this hoist. Retain these instructions
More information5.1. EXPLOSIVE TYPES..Elimination of nitroglycerin effects.
CHAPTER 5 EXPLOSIVES AND INInA TING DEVICES 5.0. TYPES OF EXPLOSIVES AND INITIAT- ING DEVICES THAT ARE USED BY THE NCF..Reduced smoke and toxic fumes. 5.1. EXPLOSIVE TYPES..Elimination of nitroglycerin
More informationFuel Meter. Instructions - Parts List. Contents B. Model , measures in gallons Model , measures in liters. For metering fuels.
Instructions - Parts List Fuel Meter 311309B For metering fuels. 80 psi (0.55 MPa, 5.5 bar) Maximum Working Pressure Model 260405, measures in gallons Model 260414, measures in liters Important Safety
More informationA NEW INITIATION SYSTEM THAT REMOVES THE OUTSIDE OR SURFACE DETONATORS FROM THE UNDERGROUND FACE. M Davis and J Fenwick Master Blaster
A NEW INITIATION SYSTEM THAT REMOVES THE OUTSIDE OR SURFACE DETONATORS FROM THE UNDERGROUND FACE Master Blaster Abstract The underground mining industry in South Africa drills in excess of 120million holes
More informationOrica New Zealand National Price List. Dunedin Mining Services
Orica New Zealand National Price List Dunedin Mining Services 1 July 2013 Table of Contents Initiating Explosives... 4 Detonating Cord... 4 Cordtex... 4 Detonators... 4 Exel Range... 4 Exel Millisecond
More informationAir Operated Diaphragm Pumps Operating and Maintenance Instructions
Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,
More informationSPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI
15 GALLON AIR COMPRESSOR Model: 7678 DO NOT RETURN TO STORE Please call 800-348-5004 for parts and service CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials
More informationTips & Technology For Bosch business partners
Tips & Technology For Bosch business partners Current topics for successful workshops No. 73/2013 Gasoline injection Ignition cables technical information In gasoline engines, the high voltage required
More informationDynaCon Instruction Manual
DynaCon Instruction Manual Table of Contents Technical Specification & Warranty.... 3 Construction, Benefits & Safe Operating Procedures... 4 Noise Levels... 5 Installation, Operation & Maintenance...
More informationFOSC-100 B/H FOSC-100 B2/H
FOSC-100 B/H FOSC-100 B2/H INSTALLATION INSTRUCTION TC-273-IP Rev A, Mar 2017 www.commscope.com Fiber Optic Splice Closure with integrated organizer system 1 1 General 1.1 The installation instruction
More informationBlizzard, PO Box , Milwaukee, WI UNDERCARRIAGE KIT. Ford Super Duty F-250/350/450/
Blizzard, PO Box 245038, Milwaukee, WI 53224-9538 www.blizzardplows.com July 15, 2010 Lit. No. 42172, Rev. 01 30269-1 UNDERCARRIAGE KIT Ford Super Duty F-250/350/450/550 2008 - Installation Instructions
More informationEC DECLARATION OF CONFORMITY
EC DECLARATION OF CONFORMITY 14 2500W INVERTER GENERATOR IM2500I CERTIFICATE OF GUARANTEE This product is guaranteed for a period of 1 Year, with effect from the date of purchase and applies only to the
More informationZip-Tex Spray Gun. Instructions A. Model psi (0.86 MPa, 8.6bar) Maximum Working Pressure
Instructions Zip-Tex Spray Gun 311159A - For water-based materials only - (Consult your material supplier for Warnings and Application Requirements) Model 249458 125 psi (0.86 MPa, 8.6bar) Maximum Working
More informationModel HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More informationSTANDARD OPERATING PROCEDURE. Standard Operating Procedure No: SOP-001 Version Number: 1.1. Vari-Stem blast hole stemming plug
ABN 24 160 854 544 STANDARD OPERATING PROCEDURE Oresome Products Use ONLY Standard Operating Procedure No: SOP-001 Version Number: 1.1 Date Approved: 15/03/2013 Date for Review: 31/12/2015 Summary: Name
More informationLab Session #1 Initiation Systems and Types of Explosives
Lab Session #1 Initiation Systems and Types of Explosives The main goal of this laboratory session is to provide a practical experience in the use of different type of explosives and initiations systems.
More informationSeries Description. 2 Specifications. Traffic Safety and Security Division. Product Bulletin Series 4000ESV 06/2017
Traffic Safety and Security Division 3M Diamond Grade TM DG 3 Reflective Sheeting Series 4000 Product Bulletin Series 4000ESV 06/2017 1 Description 3M TM Diamond Grade TM DG 3 Reflective Sheeting Series
More informationA Dyno Nobel Overview. Our Company Our Products Our Technology Our Services Your Benefit
A Dyno Nobel Overview Our Company Our Products Our Technology Our Services Your Benefit Our Company Ownership History Statistics Locations Expertise Vision Safety Incitec Pivot Limited Top 40 ASX company
More informationOPERATING MANUAL 18V Ni-Cd Battery Pack
OPERATING MANUAL 18V Ni-Cd Battery Pack 054-3105-6 Toll-free Helpline : 1-800-689-9928 IMPORTANT : Read this Operating Manual carefully before using the charger. Pay close attention to all Safety Instructions,
More information(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.
OPERATOR S MANUAL 12 VOLT LITHIUM-ION BATTERY CHARGER 140446001 (R86049) Your charger has been engineered and manufactured to our high standards for dependability, ease of operation, and operator safety.
More informationOZM-72 anti-personnel fragmentation mine Compiled by Vanja Jokic using original Russian military sources, 2011
OZM-72 anti-personnel fragmentation mine Compiled by Vanja Jokic using original Russian military sources, 2011 Main characteristics Type..Bounding fragmentation mine with all-round lethal capability Total
More informationSLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks
SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks Instructions June 2002 78-8130-2161-1-B 1 Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Cable Preparation...
More informationBranch Splice QS-2001B
Branch Splice QS-2001B Data Sheet 1. Product Description The 3M Branch Splice QS-2001B molded rubber splice kits are designed to connect extruded dielectric power cables rated 15 kv. The basic kits handle
More information3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary
3M Electrical Tapes Product Selection Guide Insulate & Protect with Quality Tapes Get your hands on 3M Tape! 3M now offers new and experienced electricians a chance to sharpen their skills with the complete
More information8400 Series Fiber Distribution System
8400 Series Fiber Distribution System Instructions January 1997 34-7041-4699-1-A 1 Contents: 1.0 General... 3 2.0 System Components... 4 3.0 System Engineering... 5 4.0 Hardware Installation... 7 5.0 Cable
More informationModel , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover
Operating Instructions 309899 Rev. A This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. INSTRUCTIONS Manufactured by Model 246818, Series A 9 in. (23 cm) roller frame
More informationRIGID ENTRY BOOT INSTALLATION GUIDE
RIGID ENTRY BOOT INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information contained
More informationEMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions
EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions Description The ElectroMelt EMK-XP Power Connection and End Seal Kit is for use with ElectroMelt EM2-XR and EM3-XR heating
More informationPressurized oil drain for collection of used lubricants and anti-freeze.
Instructions - Parts List 24-Gallon (90-Liter) Oil Ace 30864B Pressurized oil drain for collection of used lubricants and anti-freeze. Model 9577 Series A 8 psi (55 kpa,5 bar) Maximum Working Pressure
More informationInstructional Objectives. Science of blasting. Blasting Objectives. Black Powder. Explosive materials. GE 5471 ROCK ENGINEERING CH 13 Blasting
GE 5471 ROCK ENGINEERING CH 13 Blasting Dr. Norbert H. Maerz Missouri University of Science and Technology (573) 341-6714 norbert@mst.edu Instructional Objectives 1. Explain, for a given situation, where
More informationE*Star Seismic Detonators. Electronic Programmable Detonators.
E*Star Seismic Detonators Electronic Programmable Detonators. Austin Powder E*Star Seismic electronic detonators have been designed for precise control, necessary in producing accurate and consistent seismic
More informationRS Gun Front Adapter Kits
Kit Instructions RS Gun Front Adapter Kits 332520A EN For adapting the internal mix gun for specific field applications. For professional use only. Important Safety Instructions Read all warnings and instructions
More informationPressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -
Instructions Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. 311082D Pressure Roller with 24-inch Fixed Extension - For application of architectural
More information3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits
3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.
More informationREDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.
REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion KARAM A.L. www.alternatorstarter.com 1-888-515-2726 REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL
More informationFiber Splice Panel Rack Mount User Manual
Fiber Splice Panel Rack Mount User Manual Content Page INTRODUCTION... 1 Revision History... 1 List of Changes... 1 Trademark Information... 2 Admonishments... 2 1. DESCRIPTION... 2 A. Product Definition
More informationModel 1000 Low Profile Tailgate Spreader Receiver Mount
November 1, 2018 Lit. No. 94380, Rev. 06 Model 1000 Low Profile Tailgate Spreader Receiver Mount Installation Instructions Read this manual before installing or operating the spreader. The receiver mount
More informationREINFORCED LOW & HIGH PRESSURE SPRAY/TRANSFER HOSES. One-piece lengths. Service Temperature Range: -40 F (-40 C) to +125 F (+52 C)
Lightweight polyethylene-lined rubber blend hose that is the ideal choice for handling paint and paint-related products in a variety of applications. Tube Co-extruded blue LLDPE/rubber blend. Reinforcement
More informationWelding Clips. Model Due to continuing improvements, actual product may differ slightly from the product described herein.
Welding Clips Model 95637 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA
More informationHandling Precautions, Prohibitions and General Supply Notices for VARTA Microbattery GmbH CoinPower Lithium-Ion Batteries
Handling Precautions, Prohibitions and General Supply Notices for VARTA Microbattery GmbH CoinPower Lithium-Ion Batteries Current version available under www.coinpower.de Preface Lithium batteries provide
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. BII 31129 REARVIEW CAMERA 2006 RL Issue Date OCT 2005 PARTS LIST Attachment Kit P/N: 08B21-SJA-B00 Template Rear camera trim 6-Pin connector
More informationInstalling the PBX04 Push Bumper on the 2015 Chevrolet Suburban/Tahoe
25500241 Rev. A0 0915 Safety Message to Installers and Service Personnel of Emergency Vehicle Safety Equipment Installing the PBX04 Push Bumper on the 2015 Chevrolet Suburban/Tahoe The lives of people
More informationINSTALLATION/OWNERS MANUAL
INSTALLATION/OWNERS MANUAL XOBP12D PREPARATION Getting Started Thank you for purchasing the Dual Electronics XOBP12D Bandpass Subwoofer System. Although Dual has attempted to make sure all of the information
More informationSeekTech Inductive Clamp
Inductive Clamp Manual SeekTech Inductive Clamp! Read this Operator s Manual carefully before using this tool. Failure to understand and follow the contents of this manual may result in electrical shock,
More informationInstallation Instruction EPP /92
E L E C T R I C A L P R O D U C T S. D I V I S I O N Installation Instruction EPP 0275 8/92 Terminations for Screened Single Core Plastic and Rubber Insulated Cables 7.2 kv to 36 kv without Armour Before
More informationC Power Connection Kit
1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is
More informationCOYOTE LCC (Low Count Closure)
PLP Feature Focus 2009 Preformed Line Products OCTOBER 2012 Film available at www.preformed.com COYOTE LCC (Low Count Closure) Be sure to read and completely understand this procedure before applying product.
More information650mA Phase Dimmable LED Driver
Installation Guide DGLC650C18PD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095
More informationInstallation and Operation Guide
Bus-Scan 500 RF Installation and Operation Guide All Content and Information are Copyright 2018-2019 Robotics Technologies, Inc. Features and Information are subject to change without notice. All Rights
More informationVP Remote User s Manual (nvp)
VP Remote User s Manual for Sorenson (nvp) (ntouch VP - nvp ) (Enlarged view) VP Remote User s Manual (nvp) - Pages 1 of 12 - (Rev A, 10/2011) Key location #1: NOTE: If a button has two labels that has
More informationAir-Operated Double-Diaphragm Pump
Air-Operated Double-Diaphragm Pump Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationFIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails
FIST-GSS2 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf MK2 Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Optional extra s 3 Installation of the shelf 3.1
More informationEX Series User Manual
MODELS: EX90L T4 IIB 720 DS, EX90L T4 IIB 1440 SS, EX90L T4 IIC 720 SS EXIN LIGHT EX & INDUSTRIAL LIGHTING EX Series EX90L T4 IIB 720 DS, EX90L T4 IIB 1440 SS, EX90L T4 IIC 720 SS Contents 0. Introduction
More informationAUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS
AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS The original TOMMY GATE hydraulic lift Assembling the Auxiliary Battery Box 1. Remove the cover from the auxiliary battery box by removing the two nuts and
More informationh Technical Product Data CC Pressure Pipe Systems
h Technical Product Data CC Pressure Pipe Systems Amiblu Holding GmbH All rights reserved. Publication: 09/2018 This version replaces all previous versions. For all current data please visit our website
More informationModel For petroleum products and other fluids compatible with aluminum and buna-n seals.
Instructions - Parts List Piston Hand Pump 311308C Model 260407 For petroleum products and other fluids compatible with aluminum and buna-n seals. Model 260406 For herbicides and other chemicals or fluids
More informationUSER GUIDE EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY INTELLIBOOST ULTRA RG600 12V 600A REV 1.16B
WWW.RUGGEDGEEK.COM USER GUIDE EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY INTELLIBOOST ULTRA RG600 12V 600A REV 1.16B IMPORTANT THE RG600 IS AN EMERGENCY TOOL AND SHOULD BE KEPT FULLY CHARGED, IN CASE
More informationModel NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More informationPRESENTATION OF NITROERG S.A. Seminar: Polish Contribution to the EU Raw Materials Initiative Brussels, 6th November, 2017
PRESENTATION OF NITROERG S.A. Seminar: Polish Contribution to the EU Raw Materials Initiative Brussels, 6th November, 2017 Elżbieta Błotny Marketing and Business Development Manager MISSION AND VISION
More informationELB ELB
ELB-35-600 ELB-35-610 600A T-Body Elbow Connectors for Copper Tape (CT), Jacketed Concentric Neutral (JCN), and Concentric Neutral (CN) cables up to 35kV class Safety Instructions When installing electrical
More information3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project
3M Electrical Markets Division Rubber, Mastic and Specialty Tapes Application Guide Choose the Right Tape for your Electrical Project 2 Table of Contents Insulating and Splicing...4 Scotch Linerless Rubber
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationFIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails
FIST-GSS2 FIST-GSS3 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Mounting the shelf
More informationDOCUMENT OBSOLETE. Volition. VF-45 Socket Termination and Maintenance Cleaning Kits COOL HAND TOOLS. CLEAN UP YOUR ACT. VF-45 Socket Termination Kit
Volition VF-45 Socket Termination and Maintenance Cleaning Kits COOL HAND TOOLS. VF-45 Socket Termination Kit Get your hands on a Volition VF-45 Socket Termination Kit from 3M and you will have everything
More informationUtility Mount. Tailgate Spreaders. Installation Instructions CAUTION. Read this document before installing or operating the spreader.
May 15, 2017 Lit. No. 96494, Rev. 01 Utility Mount Tailgate Spreaders Installation Instructions Read this document before installing or operating the spreader. A DIVISION OF DOUGLAS DYNAMICS, LLC SAFETY
More informationFiber optic splice closure
FOSC-450A I N S T A L L A T I O N I N S T R U C T I O N TC-772-IP Rev A, Mar 2017 www.commscope.com Fiber optic splice closure Content 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Accessories
More informationFOSC-400A4 INSTALLATION INSTRUCTION
FOSC-400A4 INSTALLATION INSTRUCTION TC-441-IP Rev A, Mar 2017 www.commscope.com Fibre Optic Splice Closure with integrated organiser system 1 General 1.1 The installation instruction describes the necessary
More information6 & 12 Volt Battery and Systems Tester with 100 Amp Load
6 & 12 Volt Battery and Systems Tester with 100 Amp Load Form No. 841-731 -000 DESCRIPTION This Load Tester tests 6 or 12 volt automotive-size lead-acid batteries under load. It will also test 6 or 12
More informationMINISTICK TM UV Germicidal Ultraviolet Light
MINISTICK TM UV Germicidal Ultraviolet Light Installation & Operation Manual 120V - Part # 19400 230V - Part # 19401 GENERAL This product emits germicidal ultraviolet (UV-C) light to help disinfect the
More informationSBC12 H Operating instructions Mode d emploi Manual de instrucciones
*254901* 254901 SBC12 H Operating instructions Mode d emploi Manual de instrucciones Safety Precautions Read all Instructions GENERAL SAFETY RULES FOR ALL BATTERY OPERATED TOOLS WARNING! Read and understand
More informationLT-EL138 LED Flashlight
LT-EL138 LED Flashlight 1 2! CAUTION! If you need to mount the flashlight onto a firearm, make sure firearm is not loaded before installation. Remove magazine and examine chamber. Use safe handling procedures
More informationCougar DC Truck Vibrators
Cougar DC Truck Vibrators Go to Cougar DC Truck Vibrators web page Operator s Manual M3952 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION OF THE MATERIAL;
More informationPSI Anti-Corrosion Tape
General information Technical specifications Requirement evaluation Application instructions Certificates PSI Anti-Corrosion Tape 8 Pipeline Accessories 85 The Systems PSI anti-corrosion tapes have been
More informationKushlan Products, Inc. !IMPORTANT! Read Me First!
Kushlan Products, Inc.!IMPORTANT! Read Me First! Thank you for purchasing this Kushlan Product. We hope you will enjoy using it for many years. Be sure to keep your box and all packing material in case
More information3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series
3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series Data Sheet 1. Product Description 3M Cold Shrink Termination Kit QT-III 7672-S-8 Series contains one silicone rubber termination
More informationFIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction
FIST-FPS I N S T A L L A T I O N I N S T R U C T I O N Front Patching Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Side cable termination directly on
More informationLoose Parts Note: Determine the left and right sides of the machine from the normal operating position.
Brake Kit Dingo TX 0 & Compact Utility Loader Part No. 0 0 & 0 Loose Parts Note: Determine the left and right sides of the machine from the normal operating position. Description Qty. Use Drive wheel Brake
More information(KERNEL) SAND BLAST CABINET ( 220L ) ASSEMBLY & OPERATION INSTRUCTION
Model 272622 (KERNEL) SAND BLAST CABINET ( 220L ) ASSEMBLY & OPERATION INSTRUCTION (1 st version) October 2014 1 / 12 PRODUCT LIMITED WARRANTY The product is guaranteed for 12 months from date of manufacturer
More informationNEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be
NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT User Manual Endoscope reprocessing the the way way it it should be be 1 Medi-Newt Neutralization System Instruction Manual 50096-951 Rev C 2011,
More information37SCENE 46SCENE 79SCENE
Installation and Operation Instructions LED SCENE LIGHT LED SCENE LIGHT 37SCENE 46SCENE 79SCENE 37SCENE 46SCENE Introduction The 37SCENE, 46SCENE, 79SCENE LED Scene Lights are designed for the emergency
More informationSPECIFICATIONS GENERAL SAFETY RULES PERSONAL SAFETY. Save This Manual TOOL USE AND CARE WORK AREA
SPECIFICATIONS 2 Forged Safety Latch Hooks Cable extends to: 44 Drop forged steel hanging bracket Heavy duty 3/16 Steel Cable Pulling Capacity: 1200 LB. One piece double ratchet gear Save This Manual You
More informationVDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements
VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,
More informationInstalling the PBX-PIT01 or PBX-PIT05 Pit Bar in the Ford Police Interceptor Utility
25500242 Rev. B0 0216 Safety Message to Installers and Service Personnel of Emergency Vehicle Safety Equipment Installing the PBX-PIT01 or PBX-PIT05 Pit Bar in the 2011 2016 Ford Police Interceptor Utility
More information3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit
3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions
More informationCordless Make Up Mirror WITH ILLUMINATED 1X AND 10X MAGNIFICATION PLUS NIGHT LIGHT
Cordless Make Up Mirror WITH ILLUMINATED 1X AND 10X MAGNIFICATION PLUS NIGHT LIGHT TABLE OF CONTENTS Warnings and Cautions....1 Location of Parts and Controls....6 Installing the Batteries...8 Using the
More informationKeystone Butterfly valves ParaSeal Installation and maintenance instructions
Before installation these instructions must be fully read and understood Please read these instructions carefully Hazard potentials: disregarding of instructions improper use of product insufficiently
More informationFLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE
FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information
More informationSurface Protective Systems
Surface Protective Systems Technical information Oxydur VEL-SR Mechanical applied electrically conductive laminate system Base Vinyl ester resin Material Group Membranes Tank- / vessel linings - laminates
More information29048, 29049, 29050, 29051, 29052, 29053, 29054,
April 15, 2014 Lit. No. 29225, Rev. 11 29048, 29049, 29050, 29051, 29052, 29053, 29054, 29400 5 HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM w/2 PLUG SYSTEM HARNESSES Installation Instructions Read
More informationInstallation Instruction EPP /02. Terminations for Screened Single Core Polymeric Insulated Cables up to 24 kv without Armour
R Installation Instruction EPP-0778-11/02 Terminations for Screened Single Core Polymeric Insulated Cables up to 24 kv without Armour Type: IXSU-F / OXSU-F Tyco Electronics Raychem GmbH Energy Division
More information1 GENERAL INFORMATION
Broadcast and Entertainment Products ProAx Triaxial Camera Connectors Installation Instructions Content Page 1 GENERAL INFORMATION... 2 1.1 Standard Tools... 3 1.2 ADC ProAx Triaxial Cable Strip Gauge...
More informationAccuGlide. HST 3-Inch HST 3-Inch Taping Heads. Instructions and Parts List. Important Safeguards. Important. Type 29100
Instructions and Parts List AccuGlide TM HST 3-Inch HST 3-Inch Taping Heads (Upper) (Lower) Important Safeguards Turn to page four for operating safety information. Type 29100 Important It is recommended
More information