TENDER NO. BHEL/NR/SCT/ GGSRP BATHINDA / C&I / 676
|
|
- Prosper Lawson
- 5 years ago
- Views:
Transcription
1 BOQ CUM RATE CHEDULE FOR CONTROL AND INTRUMENT WORK AT GURU GOBIND INGH REFINERIE PROJECT (CPP) BATHINDA (153 MW) OF HPCL MITTAL TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / 676 CONTROL PANEL/RACK/CONOLE 1 MARK-VI TURBINE CONTROL PANEL 2257X909X GT AUX. PANEL 1000X800X GT CO2 PANEL 800X400X INLET AIR FILTER PANEL 400X660X1000 No. 02 No. 02 No. 02 No EVAP. Cooling ystem Panel No HMI tation for GT (consists of CPU, Monitor 21,Keyboard,Printer,Network switches) 7 DC Panel for TG,BOP & G 750X750X BM PLC ystem Panel for UB,HRG 800X800X2415 et 02 No. 68 No. 26
2 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / BM PLC marshalling Panel for UB,HRG 1200X800x2100 No Network panel 750X750X EC RTU Panel 1000x1000x EC Marshalling Panel 1000x1000x Barrier Panel 800X800X HM Panel 750X750X Auto ynchroniser Panel 1200X800x2200 No. 02 No. 22 No. 60 No. 04 No. 01 No EC OPC erver/data Logger/Gateway et ACDB,DCDB 1200X600X Max Engineer/ torian/ Operator/max Link/ max OPC tation, 24 TFT Monitor, Historian PC 19 Printers(A4-colour,B/W,Dot Matrix, Alarm & event, Log, Historian,screen copier) with Printer Table & Accessories No. 04 No. 35 No. 14 (EAL AND IGNATURE OF TENDERER) Page 2 of 13
3 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / UP Panel 1200X800X2355 No UP Distribution Board 1200X900X Plant Communication ystem 686X1136X PA system 800X600X LOCAL BURNER PANEL for UB,HRG 1000X900X V Cell Booster(800Ah/700Ah) 650X550X1000 No. 04 No. 01 No. 01 No. 12 set DC scanner Air fan starter Box No V Battery Fuse Box set AC UP & UP Battery et 01 INTALLATION,CALIBRATION&COMMIIOING OF LOCAL / FIELD INTRUMENTATION / EQUIPMENT 29 Flow Meter Nos 18 (EAL AND IGNATURE OF TENDERER) Page 3 of 13
4 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / Temp. Transmitter/Pressure Transmitter /Differential Pressure Transmitter Nos Level Gauge/ Level witch /Radar Level instruments/ Level transmitters olenoid Valves De- superheater Nos 143 Nos 179 Nos Pressure Gauges/ Temp. Gauges/Diff. Pressure Gauges Nos Pressure witch/temp. witch Nos Limit witch Nos Air Filter Regulators Nos Electric Heater Nos MTM THERMOCOUPLE Nos Thermocouple/Temperature Element (RTD) Nos 547 (EAL AND IGNATURE OF TENDERER) Page 4 of 13
5 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / Vibration/Axial Disp./Velocity probes Nos peed measuring Loop Nos Fire/Hazardous gas Detectors Nos Magnetic Pickups Nos LVDT Nos Hooters, trobes, Call Points Nos Electrical loop checking Nos EWLI & BHELMHO with15mtr PTFE cable & electrode et EWLI Ascertor Cabinet with display units with 1200 mtr. cables et WA analyzer set with Dry & Wet Panel ET ANALYER(MOKE DENITY / ox, Nox, CO/HC ANALYER) with H Panel ET 10 (EAL AND IGNATURE OF TENDERER) Page 5 of 13
6 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / Oxygen analyzer with control unit ET PM Analyser with control unit ET Thermometers(Gas Filled/Bimettalic) Nos Flame canner for UB,HRG Nos THERMOWELL Nos Hand Held Communicator Nos Alarm Management ystem et CCTV Monitor No Master Clock ystem et Hart Management ystem et Local gauge rack 1700X1200 Nos 20 (EAL AND IGNATURE OF TENDERER) Page 6 of 13
7 63 LIE 1000X600X2000 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / 676 Nos Rigid Conduit Mtrs 250 CONTROL/IGNAL/CREENED LAYING,DREING & CLAMPING 1.1kV,PVC insulated, FRL outer-sheathed CABLE UNIT QTY 65 1P X 1.5 Q MM Mtr P X 2.5 Q MM Mtr P X 0.5 Q MM Mtr P X 1.5 Q MM Mtr P X 1.5 Q MM Mtr P X 0.5 Q MM Mtr P X1.5 Q MM Mtr (EAL AND IGNATURE OF TENDERER) Page 7 of 13
8 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / P X2.5 Q MM Mtr P X 0.5 Q MM Mtr P X 1.5 Q MM Mtr P X 2.5 Q MM Mtr C X 2.5 Q MM Mtr C X 2.5 Q MM Mtr C X 1.5 Q MM Mtr C X 2.5 Q MM Mtr C X 2.5 Q MM Mtr C X 2.5 Q MM Mtr C X 2.5 Q MM Mtr 3000 (EAL AND IGNATURE OF TENDERER) Page 8 of 13
9 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / C X 2.5 Q MM Mtr T,1.5 Q MM Mtr T,1.5 Q MM Mtr T,1.5 Q MM Mtr T,1.5 Q MM Mtr T/C Extn. Cable, Chromel alumel cable Mtr Flame scanner cables Mtr CABLE TRAY ERECTION INCLUDING UPPORT & COVER FABRICATION 90 Ladder/ Perforated type Cable tray, W=300mm Mtr Ladder /Perforated type cable tray, W=150mm Mtr Ladder /Perforated type cable tray, W=100mm Mtr 2500 (EAL AND IGNATURE OF TENDERER) Page 9 of 13
10 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / 676 REDUCER LADDER/ PERFORATED TYPE (50%LH/50%RH) 300MM - 150MM No. 45 IMPULE PIPE/ TUBE ALONG WITH FITTING 93 PIPE above 2 MTR 94 TUBE 1/2 MTR 95 PIPE 3/4 MTR 96 PIPE above 1 MTR 97 PIPE less than 1 MTR 98 PIPE 1/4 MTR 99 TUBE ¼ MTR 100 C PIPE 3/4 MTR (EAL AND IGNATURE OF TENDERER) Page 10 of 13
11 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / A PIPE 3/4 MTR Pipes 1 for Instrument air MTR 2000 JUNCTION BOXE/INDICATION BOXE/PB TATION 103 Junction Box up to 48WAY Nos Junction Box up to 24WAY Nos PB tation/box Nos Explosion Proof Junction Boxes Nos COMMIIONING/CALIBRATION OF MOTORIED/PNEUMATIC ACTUATOR/GATE/CONTROL VALVE Commissioning of Motorised Valves /Actuators Commissioning/ Calibration of Pneumatic Valves No. 54 No Control Valves/ On-Off Control Valves No. 146 (EAL AND IGNATURE OF TENDERER) Page 11 of 13
12 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / afety Relief valves/ Temperature afety Valve/ Pressure afety Valve/ On-Off Control Valves Nos Air release valves Nos Power cylinder for FD fan Nos Electrical Actuator for FD fan No. 08 INTALLATION & FABRICATION OF TRUCTURE TEEL 114 Channel, Angles, Flats, Plate etc. MT 8 Notes: TOTAL 1) All dimensions are in mm unless otherwise specified. 2) The contractor is required to quote unit-rate as well as total price against each item in the above schedule. ub-total on each page shall be indicated and brought forward to next page and duly signed. The contractor shall ensure that grand total on this page is arithmatically checked and corrected and certified accordingly while signing below. Despite this if any calculation error is (EAL AND IGNATURE OF TENDERER) Page 12 of 13
13 TENDER. BHEL/NR/CT/ GGRP BATHINDA / C&I / 676 noticed after tender opening. BHEL reserves the right to deal with it as deemed fit at their end. 3) The quantities indicated against each item above are tentative and same are liable to vary depending upon the site requirement. The contractor has to erect/ commission all items indicated by BHEL Engineer for achieving unit wise milestone 4) The Rate shall be entered in figures as well as in words. In case of difference in rates between words and figures THE LEER OF THE TWO will be treated as valid rate. 5) In case of omission in quoting any rate, the evaluation will be done considering the highest quoted rate obtained against that item but the work, if awarded, will be on the lowest quoted rate obtained against that item. 6) The bidders shall enter both Unit Rate & Amount. In case of any mismatch between Total Amount based on Unit Rate & Total Amount as quoted, the higher of the two shall be considered for evaluation and the lower of the two shall be considered for award. 7) Evaluation of the bids shall be done based on total price against BOQ. (EAL AND IGNATURE OF TENDERER) Page 13 of 13
S P E C I F I C A T I O NS
FOR OFFICIAL USE ONLY T FOR PUBLICATION TENDERER S COPY ORIGINAL COPY T E N D E R S P E C I F I C A T I O NS TENDER. BHEL/NR/SCT/ GGSRP BATHINDA / ELE / 659 FOR Erection, testing, commissioning, post commissioning,
More informationS P E C I F I C A T I O N
T E N D E R S P E C I F I C A T I O N No. BHE/PW/PUR/HZL-CLE/487 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, ASSISTANCE
More informationS P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836
FOR OFFICIAL USE ONLY NOT FOR PUBLICATION TENDERER S COPY ORIGINAL COPY T E N D E R S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836 FOR ERECTION, TESTING, COMMISSIONING TRIAL OPERATION
More informationPRICE BID - PART: I I
T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/PLT-ELE/603 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING
More informationBHEL PSWR NAGPUR VOL-II-PRICE BID T.S.NOBHE/PW/PUR/VNT5-CNI U#13/1354 Sub: Price Bid for C & I package of 1x500MW NTPC VINDHYACHAL UNIT-13
I1.0 Cable tray and Accessories I.1.0 I1.0.1 Perforated cable tray and accessories (with or without cover) 50mm Meter 6105 I1.0.2 Perforated cable tray and accessories (with or without cover) 100mm Meter
More informationTENDER SPECIFICATION
TENDER SPECIFICATION No. BHE/PW/PUR/PDVT-CNI/1079 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING AND HANDING
More informationTENDER SPECIFICATION BHEL:PSSR:SCT: 1307
TENDER SPECIFICATION BHEL:PSSR:SCT: 1307 FOR Handling at Site Stores / Storage yard, Transportation, Erection, Testing and Commissioning of Control & Instrumentation System for Unit- 1 of 1x500 MW Unit
More informationS P E C I F I C A T I O N
T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/AMRT-CNI/946 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING
More informationS P E C I F I C A T I O N No. BHE/PW/PUR/JNGI-CLE/429
T E N D E R S P E C I F I C A T I O N No. BHE/PW/PUR/JNGI-CLE/429 FOR Handling at Storage Yard/Stores, Transportation to Site of Work; Erection, Calibration, Testing, Commissioning Including Final Painting
More informationS P E C I F I C A T I O N
T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/KKT-ELE/627 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING
More informationTENDER SPECIFICATION. Rayalaseema Thermal Power Project (Muddanur) V.V.Reddy Nagar, Kalamalla Post,Cuddapah Dt, AP
TENDER SPECIFICATION BHEL: PSSR: SCT: 1336 FOR Handling at Site Stores / Storage yard, Transportation to Site of Work, Erection, Testing and Commissioning of HT and LT Electrical Package for Unit 5-1x
More informationS P E C I F I C A T I O N
T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/BHT-ELE/647 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING
More informationVOLUME :II PRICE BID BOOK NO.
T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/CHT-ELE/1127 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING
More informationS P E C I F I C A T I O NS TENDER NO. BHEL: NR (SCT): BAWANA: ELECT-CNI: 649 FOR
FOR OFFICIAL USE ONLY NOT FOR PUBLICATION TENDERER S COPY ORIGINAL COPY T E N D E R S P E C I F I C A T I O NS TENDER NO. BHEL: NR (SCT): BAWANA: ELECT-CNI: 649 FOR Erection, testing, commissioning, post
More informationS P E C I F I C A T I O N
T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/BSJI-ELE/483 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, ASSISTANCE
More informationZirconia Oxygen Probe
Data Sheet SS/ZFG Issue Zirconia Oxygen Probe ZFG Series Environmental Certification MCERTS SIRA Certificate MC99000 Combustion monitoring control true wet measurement of net excess oxygen in situ measurement
More informationTENDER SPECIFICATION
TENDER SPECIFICATION No. BHE/PW/PUR/SKT-ELE/1083 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING AND HANDING
More informationBOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH
BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH 1. WIRING TO POINTS 1 Recess conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper FRLS wire
More informationMechanical Engineering
Mechanical Engineering Stepper Motor Drive Full step controlling of stepper Motor Single step, low and high speed, Forward and Reverse Small stepper Motor with driver and Power Circuit Necessary Power
More informationSYMBOLS & STANDARDS CHEMIN-IIM (XVI E) 1) INSTRUMENT ABBREVIATIONS PRESSURE TEMPERATURE FLOW LEVEL P : PRESSURE
1) INSTRUMENT ABBREVIATIONS PRESSURE P : PRESSURE CHEMIN-IIM (XVI E) SYMBOLS & STANDARDS PI : PRESSURE INDICATOR PG : PRESSURE GAUGE PCV : PRESSURE CONTROL VALVE PT : PRESSURE TRANSMITTER PIT : PRESSURE
More informationGMP dry heat ovens for depyrogenisation and sterilisation
GMP dry heat ovens for depyrogenisation and sterilisation Product Concept Standard specifications Options and accessories Commisioning services What s a GMP sterilizer? The term GMP sterilizer has no official
More informationPSER:SCT:BRL-E1018:09
TCN - 02 Ref: PSER:SCT:BRL-E1018:TCN-02 Date: 10-06-2009 Sub Tender change notice (TCN) 02. Job ERECTION TESTING & COMMISSIONING OF ALL ELECTRICAL, CONTROL & INSTRUMENTATION WORK OF HRSG, GTG, BOP, GT
More informationBURNERMATE UNIVERSAL INDUSTRIAL BOILER CONTROLLER System Overview
BURNERMATE UNIVERAL INDUTRIAL BOILER CONTROLLER ystem Overview ystem Overview Fully Metered combustion control is now available off the shelf in an economical, pre-engineered, parameter-driven control
More information3. MECHANICAL SEALS GROUP 3.1 MECHANICAL SEALS 3.2 FLUSHING PLANS
LIST OF ITEMS BEING PROCURRED FROM MSEs MSE Manufacturers of these items may visit vendor registration page for registration, if not already registered with the company SL. NO TYPE OF ITEM 1. CASTINGS
More informationTENDER DOCUMENT. for SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF KITCHEN EQUIPMENT AT. Single-Stage: Two-Envelope.
Vol II BoQ1 STATE INSTITUTE OF HOTEL MANAGEMENT AND CATERING TECHNOLOGY (JOINTLY SPONSORED BY GOVT. OF INDIA & GOVT. OF TAMILNADU) THUVAKUDI, TIRUCHIRAPPALLI- 620 015. TENDER DOCUMENT for SUPPLY, INSTALLATION,
More informationBHARAT HEAVY ELECTRICALS LIMITED Industrial Valves Plant Goindwal (AMRITSAR) Enquiry Date:
BHARAT HEAVY ELECTRICALS LIMITED Industrial Valves Plant Goindwal 143422 (AMRITSAR) ENQUIRY Phone:+91 1859 223381 (+91 1859 222002, 222036, 222039 Extn 117) Fax :+91 1859 222 061 Email :srk@ivp.bhel.co.in
More informationii) PC based works station with monitor and printer having below mentioned specifications:
GAS CHROMATOGRAPH ANNEXURE-A Gas with TCD,FID & Methanizer as below for NFL Bhatinda, Panipat & Nangal Unit (one each): i)gas customized & factory fitted capable of concurrent (parallel) operations of
More informationICX-CMOS-S-2004 Senior I&C Technician PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS
102068-ICX-CMOS-S-2004 Senior I&C Technician Holds an Industrial Diploma and has about 14 years hands-on experience working as I&C Technician at several Power Plants and other industrial projects. PERSONAL
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 21/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Construction of second floor above central block at ACES building (SH: Electrical works). Name of the
More informationAnnexure-I (PART-B) Estimated Items & Qty. for Instrument Maint. Jobs A.R.C Item No. Unit Rate (Rs.)
Annexure-I (PART-B) Estimated Items & Qty. for Instrument Maint. Jobs A.R.C. 2011-12 Item 1.0.0 LEVEL MEASURING INSTRUMENTS 1.1a Removing of level gauges(pr. Rating < 40 Kg/cm2) 60 1.1b Fixing of level
More informationTender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read
Tender for procurement of Passive Components of LAN & Wi-Fi and their installation Corrigenda Sl. No. Annexure/Clause For Read Item Specifications Item Specifications 1. Annexure-I, Point No. 1.3 24 Port
More informationElectronic Temperature Sensor
Connection Head Type RTD or Element or RTD Cast Aluminum, Polypropylene or Stainless Steel Head Weather Proof Welded or Spring Loaded TDD TMD Hot Junction: Head Process Connection Conduit Connection 100Ω
More informationB.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD
B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD Soubhagya Nayak Associates Plot No-736,Sector-3,Niladrivihar,Chandrasekharpur,Bhubaneswar.21
More informationTotal Ex. Tax/VAT. (Rs.) (if any) in Rs. (Bought out/direct) length 587M 226M
ORISSA POWER TRANSMISSION CORPORATION LIMITED Supply & Laying of 132 KV XLPE Double Circuit (4 cable per Circuit including one spare) underground 1000 Sq. mm annealed Copper XLPE EHV Cable with Associated
More informationThermocouples. Thermocouple
Thermocouple Nimish Shah Thermocouples Most frequently used method to measure temperatures with an electrical output signal. Outline What Is A Thermocouple Sensor?? Basic Working Principle Practical Thermocouple
More informationMitsubishi Hitachi Power Systems America. Coal to Gas Conversions
Mitsubishi Hitachi Power Systems America Coal to Gas Conversions Joe Brown AMS Product Manager 9/28/15 MITSUBISHI HITACHI POWER SYSTEMS AMERICAS, INC. Units Faced with Environmental Challenges Shut Down
More informationSec 1 TROUBLESHOOTING VARIABLE SPEED DRIVE ASC450 SOFTWARE
Sec 1 Sec 2 Sec 3 Sec 4 Sec 5 Sec 6 Sec 7 Sec 8 Sec 9 Sec 10 Sec 1 OVERVIEW MOUNTING WIRING PARAMETERS TROUBLESHOOTING O2 TRIM VARIABLE SPEED DRIVE MODbus ASC450 SOFTWARE SPECIFICATIONS Sec 1 Sec 2 Sec
More informationGUJARAT NARMADA VALLEY FERTILIZERS COMPANY LIMITED MTPA PAC PROJECT SECTION 6 ANNEXURE 4.7 SPARES, INSP AGENCY & DOCUMENTATION
A. SPARE PARTS Outline for the supply of Spare Parts for various items is as elaborated below: A-1 MACHINERY Commissioning spares will be as per the manufacturer s recommendations. For 2 years of normal
More informationSCHEDULE OF QUANTITY
SCHEDULE OF QUANTITY ELECTRICAL WORKS PM PALEM BRANCH, VISAKHAPATNAM SL NO. DESCRIPTION OF ITEM / WORK UNIT Qty RATE AMOUNT PART - A : ELECTRICAL WORKS 1 Energy Meter Cubicle : 2 Emergency Off Box (Red
More informationLAR Training. Series 8000 Pneumatic Safety Shut Off Valves Mark Lampe May,
LAR Training Series 8000 Pneumatic Safety Shut Off Valves Mark Lampe May, 18 2015 Series 8000 Pneumatic Valve Unique vertical space saving design Maintenance free gas and fluid seal that eliminates packing
More informationFlow Measurement Technology Training
Flow Measurement Technology Training Küppers Elektromechanik GmbH TASI Flow Division Küppers Elektromechanik GmbH TASI s Flow Group Territories Küppers Elektromechanik GmbH AW-Lake History AW Company formed
More informationTRASH RACK CLEANING MACHINE
TRASH RACK CLEANING MACHINE 1 SCOPE The work includes the design, manufacturing, supply, transportation, handling, storage, installation (including 1 st and 2 nd Stage embedded parts and any other necessary
More informationTubeskin thermocouple assembly Model TC59-V
Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications
More informationINVITATION FOR QUOTATION. TEQIP-III/2018/gcej/Shopping/50
INVITATION FOR QUOTATION TEQIP-III/2018/gcej/Shopping/50 15-Sep-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the
More informationPROCESS INSTRUMENTATION
INSTRUMENTS PROCESS INSTRUMENTATION Measuring your world since 1965 D C B A NOTE 1 NOTE 2 NOTE 3 NOTE 4 NOTE 5 4 4 3 REOTEMP Instrument Corporation 10656 Roselle Street San Diego, CA 92121 USA Phone: (858)
More informationLIQUID MEASUREMENT STATION DESIGN Class No
LIQUID MEASUREMENT STATION DESIGN Class No. 2230.1 Michael Frey Systems Sales Manager Daniel Measurement & Control, Inc. 5650 Brittmoore Rd. Houston, Texas 77041 INTRODUCTION The industry continues to
More informationZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement
Data sheet DS/ZMT/LO EN Rev. J ZMT & ZFG Superior technology and quality from the world leader in oxygen measurement Integral reference-air supply option avoids necessity for additional equipment Dual
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description
More informationTENDER DOCUMENT PART-II
1 NATIONAL BANK FOR AGRICULTURE AND RURAL DEVELOPMENT TAMILNADU REGIONAL OFFICE TENDER DOCUMENT PART-II (PRICE BID) Supply, Installation, Testing and Commissioning of 25 kva DG Sets with Acoustic Enclosure
More informationPIPING TO HAZARD PIPING TO HAZARD AGENT SOURCE AGENT SOURCE TOP VIEW TOP VIEW
Kidde Engineered Fire uppression ystem Designed for use with 3M Novec 1230 Fire Protection Fluid 3-Way Directional Ball Valve Data heet Effective:March 2005 K-45-9070 FEATURE For use with Kidde Engineered
More informationRosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol
Quick Installation Guide Rosemount 3095FC Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol Step 1: Mount the Transmitter Step 2: Connect Wiring Step 3: Set Jumpers and Apply Power
More informationINTERNATIONAL METAL ENGINEERING
INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE
More informationFoxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element
Product Specifications Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element PSS 1-5A1 A MODEL 2761 MODEL 2781 The Foxboro Dew Point Measurement
More informationNIT No.:-10/WEX/MCR/HYD. PRESS/2-303/ /Dt
Annexure-1 NIT No.:-/WEX/MCR/HYD. PRESS/2-303/21-12/Dt.02.03.22 Name of work:-retrofitting of new hydraulic power pack on 63 Ton Hydraulic Press, Plan No.1/2-303 SCOPE OF SUPPLY AND WORK: 1.0 Purpose of
More informationUNITECH makes the indication and control of Process Parameters
T e c h n i c a l M a n u a l UT1596/UT1572/UT1584/UT1548 PID CONTROLLERS OUT AT AL1 AL2 0% 20 40 60 80 A/M OUT AT AL1 AL2 100% OUT OFF AT AL1 AL2 OUT OFF AT AL1 AL2 Model :UT 1144 Model :UT 1149 Model
More informationINSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER
5500 COMBUSTION SAFETY CONTROL INSTALLATION MANUAL FOR 5500 COMBUSTION SAFETY CONTROLLER WARNING This manual must be read in its entirety before installation of this controller. Installation must be performed
More informationCapacities and Operating Data
CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000
More informationMandatory Spares Part List
< Mandatory Spares Part List FOR HINDUSTAN PETROLEUM CORPORATION LTD. VISAKH REFINERY DHT Project JOB NO. : 6261 TOYO ENGINEERING INDIA LIMITED MUMBAI INDIA < Security Level 2 > DOC.No. DHT Project Sheet
More informationChapter 11. Control System Instrumentation
Chapter 11 Control System Instrumentation Measuring Instrumentations Transducers and Transmitters The typical process measuring instrument consists of sensing elements and transmitters (driving elements).
More informationWEIGHTS & DIMENSIONS
Doc. No.: BHEL/PESD-E&C/RUPPL-GTG/WD/001, Rev 00, 1 TH AUG. 2012 WEIGHTS & DIMENSIONS BHARAT HEAVY ELECTRICALS LIMITED Page 1 of Annexure-1 PROJECT :: RUPPL-2xFr-B GTG DATE: 1/08/12 BIDDER :: Rev.00 ANNEXURE
More informationProtection Systems. 3-Way Directional Valve P/N: XX-00X. A UTC Fire & Security Company FEATURES
Effective: Nov. 2010 Fenwal Phoenix Directional Valve P/N: 93-2200XX-00X TM R Protection ystems A UTC Fire & ecurity Company F-93-121 FEATURE For use with Fenwal Phoenix ystems Cost-Effective Option for
More informationHINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3
Page 1 of 7 HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3 STANDARD SPECIFICATION FOR OIL MIST LUBRICATION SYSTEM DOCUMENT NO : 44LK-5100-704/M.02/0024/A4
More informationOswego County Department of Solid Waste
Oswego County Department of Solid Waste Patrick Ryan, Energy Recovery Facility Chief Facility Operator 2018 Stack Flow Meter replacement (Two complete systems) The Oswego County Energy Recovery Facility
More informationPARTS MANUAL. PS314SBI Gas and Electric Ovens. Models: for domestic and standard export ovens PS314SBI Middleby Marshall, Inc.
Parts Gas & Electric (AGA[CSA]/UL) P/N 38812 Rev. B V2 1/00 Gas and Electric Ovens Models: PARTS MANUAL for domestic and standard export ovens 2000 Middleby Marshall, Inc. is a registered trademark of
More informationThermocouple with spring-loaded tip Model TC55
Electrical temperature measurement Thermocouple with spring-loaded tip Model TC55 WIKA data sheet TE 65.55 for further approvals see page 5 Applications Bearing temperature measurement on: Pumps Gears
More informationPF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016
PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS v1.1 Revised Table of Contents 1 Common Alarms and Warnings... 1 2 Common Issues... 6 2.1 Communication problems... 6 2.1.1 Controller communication
More informationSl No. Details UOM Quantity. Delivery Schedule. Specification. Delivery Schedule. Delivery Schedule
Due Date of Cover-I Opening : 27/05/2016 15:00:00 hrs. IST (Check NLC eproc website for any change in due date of opening.) Note : Quotation should be valid for 60 days from the date of opening. Gentlemen,
More informationBlank Price bid (Bill of Quantity) for Part B contract
Blank Price bid (Bill of Quantity) for Part B contract First Year Second Year Third Year Sr.No Job Description UOM Qty per annum Unit rate Total Amount Qty per annum Unit rate Total Amount Qty per annum
More information4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.
SHEET 1 OF 5 1.0 GENERAL & SCOPE 1.1 This specification covers the design, material, construction features, manufacture, inspection & testing, Painting and packing requirements of Spring Loaded Bypass
More informationIMPLEMENTATION OF FOUNDATION FIELDBUS (FF) TECHNOLOGY IN IOCL REFINERIES
IMPLEMENTATION OF FOUNDATION FIELDBUS (FF) TECHNOLOGY IN IOCL REFINERIES 23 rd Nov 2012 Atish Chakrabarty Dy. General Manager (Projects) Indian Oil Corporation Ltd. chakrabartya@indianoil.in Global Standing
More informationHUNTLEY COMMUNITY SCHOOL DISTRICT #158 Addendum No. 1 to Bid Specifications for HVAC Preventative Maintenance Services Bid #
HUNTLEY COMMUNITY SCHOOL DISTRICT #158 Addendum No. 1 to Bid Specifications for Bid # 2017-44 8-15-17 Dear Bidders; Following is Addendum No. 1 for Bid Specification for Bid # 2017-44 for Huntley Community
More informationGeneral Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011
Product Data Sheet PDS 71-400/rev.J January 2011 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the
More informationMeasuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K
Temperature Measuring insert For thermocouple with flameproof enclosure (TC1-L) Model TC1-K WIKA data sheet TE 65.11 for further approvals see page 2 Applications Replacement measuring insert for servicing
More informationSurface thermocouple Model TC50
Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial
More informationSPECIFICATIONS OF SINGLE GIRDER UNDER SLUNG E.O.T. CRANE CAPACITY: 5 MT
1 SPECIFICATIONS OF SINGLE GIRDER UNDER SLUNG E.O.T. CRANE CAPACITY: 5 MT QUALIFICATION CRITERIA Vendor has to compulsorily meet the following requirements to get qualified for consideration of the technical
More informationBILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH
BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH SL NO. DESCRIPTION OF ITEM / WORK UNIT QTY PART - A : ELECTRICAL WORKS 1 1 Energy Meter Cubicle : a Fabrication, Supply, Installation, testing
More informationThermocouples Model TC10-E, for Additional Thermowell
Electrical Temperature Measurement Thermocouples Model TC10-E, for Additional Thermowell WIKA Data Sheet TE 65.05 Applications Chemical industry Petrochemical industry Off-Shore Machine building, plant
More informationCable thermocouple Model TC40
Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 for further approvals see page 11 Applications For direct installation into the process Machine building Motors
More informationRate (Rs.) in figure. Rate (Rs.) in words. VAT (%) Amount (Rs.) & all other taxes.
PRICE FORMAT FOR SUPPLY OF ELECTRICAL ITEMS PART B PRICE BID TITLE: PROCUREMENT OF ELECTRICAL ITEMS IN BHEL TOWNSHIP, SECTOR 17, NOIDA NIT NO: 08:AA:NOI:ADMN:Electrical Items :112:2013 14 Dated 02/08/2013
More informationQUOTE NIXON. Industrial kilns and furnaces tel: Revised 24/2/2012
QUOTE NIXON Industrial kilns and furnaces t.nixon.engineering@hotmail.co.uk tel:- 07814703759 Revised 24/2/2012 Client Clan Ceramics Consultancy ltd./ Wall Colmonoy Contact Dennis Dixon Description investment
More informationINVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-EE-09
INVITATION FOR QUOTATION TEQIP-II/2015/GJ1G02/Shopping/M-EE-09 02-Dec-2015 Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for
More information: Material Description Quantity UOM
Page : 1 / 2 OIL INDIA LIMITED (A Govt. Of India Enterprise) Tel :033 2230 1657, 1658 4, India Exchange Place, Fax :91 33 2230 2596 Kolkata-700001 E-mail :oilcalmn@cal2.vsnl.net.in ANNEXURE-I Item No./
More informationLot 26 WBS 1150 Bill of Quantities
UNITED NATIONS DEVELOPMENT PROGRAMME ITB 2016-196 Lot 26 WBS 1150 Bill of Quantities Programme Title: Right to Education in the Gaza Strip Project name: Extension and Rehabilitation Works For The Governmental
More informationNFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH
NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH Contego Latex Fire Barrier Intumescent (Also marketed in Canada by Pyrologistics,
More informationProgrammable Safety Systems for Burner Management on Gas Turbines.
Programmable Safety Systems for Burner Management on Gas Turbines. As the demand for energy throughout Australia increases the demand for alternative sources is increasing accordingly. The use of gas turbine
More informationGeneral Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...
Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG
More informationHD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2
HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2 Batteries 4 1.5V type AA batteries Autonomy 200 hours with 1800mAh alkaline batteries Power absorbed with instrument off 20μA Mains models HD2114P.2 and HD2134P.2
More informationGUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR
GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA - 390 007 TENDER FOR Design,Engineering, manufacturing, supply, erection, testing & commissioning of 66
More information1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...
1/11 29/06/2016 VENTILATION AND Buildings & Technical Services Section AIR-CONDITIONING STANDARD CONTENTS 1. GENERAL... 2 2. DUCTS, AIR VENTS, VALVES... 2 3. MONOBLOCK UNITS... 3 4. FILTRATION... 5 5.
More information+91-8048078717 Japsin Instrumentation http://www.temperature-pressure-gauges.com/ We are an ISO 9001:2015 certified organization engaged in manufacturing & exporting of Testing & Measurement Instruments.
More informationAssociated Equipment. Online Auction Of Automotive Test Rigs & Associated Equipment. Lot no. Description
Torotrak Sale 3: Automotive Test Rigs Associated Equipment (Ends: 2017-10-12 14:00:00.0) Online Auction Of Automotive Test Rigs & Associated Equipment. Lot 1001 315Kw Engine Dynamometer Dynamometer: DC
More informationReplacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-547-1000 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KH 55 thru 285 44 3 4 43 2 47 46
More informationOxySense Open P/N: S09/1098
OxySense Open P/N: S09/1098 Page 1 Overview The OxySense uses a Bosch automotive lambda sensor to measure oxygen in the exhaust gas of an endothermic generator. This signal is conveyed to the AC20 or 9120
More informationTroubleshoot Furnace (Troms)
Page 1 of 20 P-01a: Troubleshoot Furnace (Troms) SAFETY FIRST o Follow all Caterpillar facility safety standards when performing this task. o Be aware of the hazards that are associated with quenching
More informationCOMPONENT IDENTIFICATION
This CFMI publication is for Training Purpose Only. The information is accurate at the time of compilation; however, no update service will be furnished to maintain accuracy. For authorized maintenance
More informationInventory # Lot # Lead
2125800 5 Transformer Cooler 2125801 6 Valves 2125802 7 Globe Valve 2125803 8 Check Valve 2125804 9 Flow Control Valve 2125805 10 Tricentic Valves 2125806 11 Gate Valve 2125807 12 Gate Valves 2125808 13
More informationB.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH
B.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH SL.N 1. WIRING TO POINTS 1.0 Concealed conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper
More informationThermocouples Model TC10-B, for Additional Thermowell
Electrical Temperature Measurement Thermocouples Model TC10-B, for Additional Thermowell WIKA Data Sheet TE 65.02 Applications Machinery, plant and tank construction Energy and power plant technology Chemical
More informationTransmitters Sensors. Transmitters. Sensors. Pressure Temperature Humidity Air velocity Airflow
Transmitters Sensors Transmitters Sensors Pressure Temperature Humidity Air velocity Airflow Transmitters Features Designed and manufactured in France, KIMO range of transmitters is perfectly suitable
More informationUSER MANUAL RHF SERIES
Hukseflux Thermal Sensors USER MANUAL RHF SERIES Ring heat flux sensors Copyright by Hukseflux manual v1824 www.hukseflux.com info@hukseflux.com Warning statements Follow the installation instructions
More information