Mitsubishi Hitachi Power Systems America. Coal to Gas Conversions

Size: px
Start display at page:

Download "Mitsubishi Hitachi Power Systems America. Coal to Gas Conversions"

Transcription

1 Mitsubishi Hitachi Power Systems America Coal to Gas Conversions Joe Brown AMS Product Manager 9/28/15 MITSUBISHI HITACHI POWER SYSTEMS AMERICAS, INC.

2 Units Faced with Environmental Challenges Shut Down the Unit Install Lowest New Capital Combined Cost Cycle Option Eliminate all potential source of generation and potential capacity Re-power Minimize revenues to emmisions and Combined with must incur Cycle an efficient generation source burning cheap gas de-commissioning cost (Replacement Same generation benefits Very high capital cost as a Combined cost possibility) Cycle but re-using the Steam Turbine if Install possible Capital Air Quality ~ Control $1,250/kw++ Systems High Installing Capital the cost latest ~ AQCS $1,000/kw++ allows unit to remain operational with most Install Additives (DSI/ACI/ SNCR) if Fuel has low enough Sulfur and fuel flexibility Nitrogen to comply High Capital Costs: FF ~ $40/kw, DryFGD ~ $125/kw, SCR ~ $160/kw, Convert Low Upfront with increased to Natural cost while maintaining coal capability: ACI ~ $5/kw, SNCR ~ equipment Gas to maintain and manpower A $14/kw, Low cost DSI option ~ $5/kw ($26 ~ $65/kw) that eliminates most all Hg, Particulate Become and Unit Sulfur has Dual no emissions Fuel fuel flexibility Fired while (Gas & deactivating now and has Coal Higher with coal Additives) operational equipment cost and associated with Boiler, manpower Air Unit Heater can switch and to maintain Ductwork to lowest it Impacts cost fuel (Corrosion, option instantaneously, Ammonia slip, and material can meet Gas drop-out future Supply regulations concerns, line has etc.) to be available to be cost effective and efficiency goes Paying down for two slightly separate systems upfront 1

3 Units Faced with Environmental Challenges Shut Down the Unit Lowest Capital Cost Option Eliminate all potential source of generation and potential capacity revenues and must incur de-commissioning cost (Replacement generation cost a possibility) Install New Combined Cycle Minimize emmisions with an efficient generation source burning cheap gas Very high capital cost ~ $1,250/kw++ Re-power to Combined Cycle Same benefits as Combined Cycle but re-using the Steam Turbine if possible High Capital cost ~ $1,000/kw++ Install Capital Air Quality Control Systems Installing the latest AQCS allows unit to remain operational with most fuel flexibility High Capital Costs: FF ~ $40/kw, DryFGD ~ $125/kw, SCR ~ $160/kw, with increased equipment to maintain and manpower Install Additives (DSI/ACI/ SNCR) if Fuel has low enough Sulfur and Nitrogen to comply Low Upfront cost while maintaining coal capability: ACI ~ $5/kw, SNCR ~ $14/kw, DSI ~ $5/kw Unit has no fuel flexibility & now has Higher operational cost with Boiler, Air Heater and Ductwork Impacts (Corrosion, Ammonia slip, material drop-out concerns, etc.) Convert to Natural Gas A Low cost option ($26 ~ $65/kw) that eliminates most all Hg, Particulate and Sulfur emissions while deactivating coal equipment and associated manpower to maintain it Gas Supply line has to be available to be cost effective and efficiency goes down slightly Become Dual Fuel Fired (Gas and Coal with Additives) Unit can switch to lowest cost fuel option instantaneously, and can meet future regulations Paying for two separate systems upfront Financial Information based on OEM Awards and Industry Data 2

4 Natural Gas Prices (EIA) Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

5 Natural Gas Switching - Benefits Air Quality Control System Retrofits Avoided (FGD, ESP, PAC, DSI, PJFF, SCR, etc.) Reduced O&M Costs Coal Unloading, Storage & Conveying Pulverizer motors Primary Air Fans Ash Conveying, Sluicing & Disposal Sootblowing Equipment, Piping & Controls Dust Collection & Suppression Reduce manpower associated with above No Boiler Erosion/Corrosion CO2 Reduction 40% for Boiler Retrofit 4

6 Gas Conversion Technologies Design Features Three Main Components of Gas Conversion: Natural Gas Low NOx Burner modification of existing coal burner Natural Gas Piping and Control Valve Skids Flue Gas Recirculation (If Needed) to raise steam temperature and lower NOx emissions Can cost effectively maintain capacity with minimal modification 5

7 Capacity and Main Steam Temperature Issues Boilers are sized for specific Fuels: A Coal Boiler is much larger in size than a Gas Boiler of the same MW Capacity. When a Coal Boiler is converted to Gas, it is more difficult to get the reach Main Steam Temperature and Full Load Capacity. To maintain Boiler Capacity Firing Rate must be increased To Maintain Steam Temperature there are several method (if needed): Increasing Excess Air Increasing SH/RH Surface Adding Gas Recirculation for Steam Temperature Control 6

8 CFD Model Simulation Predicted performances lead to technical solutions - Temp. - CO - NOx - Heat Flux Simulation time Input : 1 hour Calc. : 1 hour - VOC emission - Burner performance - Furnace exit gas temperature Boiler Modelling is required to determine the Conversion US. : 2003/ impacts 7

9 Retrofit Gas Canes to LNB Coal Burners Maintaining Coal Firing Capability Customer 1 Customer 2 Customer 3 Boilers MW Main Steam Flow (x10 3 lb/hr) Reheat Steam Flow (x10 3 lb/hr) No Airheater Arrangement Coal Flow (x10 3 lb/hr) Coal Quality (HHV Btu/lb) Total Heat Input (x10 6 Btu/hr) Bi-Sector (Hot PA Fan) Bi-Sector (Hot PA Fan) Bi-Sector (Hot PA Fan) ,141 13,054 12, Burner Quantity 8 Front 12 Front 8 Front 8 Rear Burner Heat Input (x10 6 Btu/hr) Efficiency (%)

10 Natural Gas Performance (Estimated) Maintaining Coal Firing Capability Customer 1 Customer 2 Customer 3 Boilers MW Main Steam Flow (x10 3 lb/hr) Reheat Steam Flow (x10 3 lb/hr) No Total Heat Input (x10 6 Btu/hr) Burner Quantity 8 Front 12 Front 8 Front 8 Rear Burner Heat Input (x10 6 Btu/hr) Efficiency (%) Increase Firing Rate to Maintain Full Load 9

11 Natural Gas Performance (Estimated) Maintaining Coal Firing Capability Customer 1 Customer 2 Customer 3 Boilers MW Main Steam Flow (x10 3 lb/hr) Reheat Steam Flow (x10 3 lb/hr) No Total Heat Input (x10 6 Btu/hr) Burner Quantity 8 Front 12 Front 8 Front 8 Rear Burner Heat Input (x10 6 Btu/hr) Efficiency (%) Boiler Efficiency typically drops between %, but parasitic load is also decreased from eliminating coal and its associated equipment 10

12 Gas Conversion NOx Generation NOx is formed when Nitrogen and Oxygen are both present in High Temperature Environments All Low NOx Strategies have to manipulate one or more of these three items in various ways for the most cost effective solution Because there is no Nitrogen in Natural Gas, Lower NOx Emissions can typically be achieved when converting from Coal to Gas. 11

13 Low NOx Strategies Reduce NOx/CO Emissions by: Utilizing the Latest Generation of Low NOx Burners Multi-Lance Gas Canes for each Coal Burner Adding Over-Fire Air Utilize BOOS (Burner out of service) Air Heater By-pass Utilizing SNCR Adding Gas Recirculation (FGR and IGR) for NOx Control 12

14 General Gas Burner Arrangement 13

15 Gas Burner Gas Canes 14

16 Coal Burner Retrofit with Full Load Gas Canes Lances through Windbox Ability to Maintain Coal Firing Capability 15

17 Coal Burner - Gas Retrofit Complexity Air Register Drive 16

18 Coal Burner Retrofit with Full Load Gas Canes Ring Header inside Windbox 17

19 Coal Burner Retrofit with Full Load Gas Canes 18

20 Burner Retrofit for T-fired Boilers New Gas Burners Existing Coal Burners Ability to Maintain Coal Firing Capability 19

21 Coal Burner Retrofit for T-fired Boilers New Gas Burners 20

22 Coal Burner Retrofit for T-fired Boilers T-Fired Burner Components (Rear) Windbox Cover Plate Auxiliary Air Compartment 21

23 Flue Gas Recirculation 22

24 Flue Gas Recirculation (100 MW example) 23

25 Flue Gas Recirculation (650 MW example) 24

26 Improved NOx with Increased FGR (Front Fired Example) Guaranteed NOx Rate 0.15 lb/mmbtu 0.08 lb/mmbtu FGR Required (100 MW Front Fired) FGR Required (150 MW Front Fired) 7% 16% 10% 22% Only a small amount of FGR is needed to achieve NOx compliance even on high NOx producing units 25

27 Additional Scope Recommendations Other Natural Gas System Requirements: Piping, Valves and Supports Trip Valve Station with Vent Piping Electrical and I&C Upgrade - Class 1, Division 2 (Typical) DCS Modifications 26

28 Natural Gas Piping Skids 27

29 Natural Gas Supply Valve Skid (Typical) 28

30 Natural Gas Distribution Burner Piping Linking burners by pairs or groups of four can drastically minimize cost 29

31 Typical Scope of Work Baseline Testing Boiler Thermal Modeling Scope of Work General Engineering Including: Drawings, P&IDs, Lists & Operation & Maintenance Manuals. CFD Model of Boiler Convection Pass Flue Gas Recirculation (FGR) Fan Foundation/Supports Natural Gas Burner Modifications: CFD Modeling of Combustion Air Duct, Windbox, Burners & Furnace Combustion Emissions Modeling Burner Elements, including internal gas ring and multiple gas spuds Igniters Double Block & Vent Valve Spools Pressure Regulating Valve (PRV) Skid With Vents Flow Control Valve (FCV) Skid With Vents Flexible Metal Hoses Flame Scanners 30

32 Typical Scope of Work Natural Gas Piping, Vent Piping, & Supports Scope of Work (Continued) Flue Gas Recirculation (FGR) Fans with Electric Motor, Turning Gear & Inlet Damper Control FGR Injection Mixing Devices FGR Differential Pressure Transmitters FGR Fan Inlet & Outlet Ducts with Hangers, Supports, and Expansion Joints FGR Duct Dampers & Actuators Burner Management & Combustion Control System Engineering & Modifications (including Hardware, Software and Implementation) Demolition of Existing Equipment Erection of New Equipment Secondary Steel & Erection Disabling of Coal Firing Equipment, Including Electrical Isolation Blanking Plates for the Primary Air and Tempering Air Duct Systems Technical Advisors for Construction & Commissioning Electrical Device Upgrades of Existing Equipment (Option) 31

33 Thank you very much MITSUBISHI HITACHI POWER SYSTEMS AMERICAS, INC. 32

C C A. Combustion Components Associates, Inc.

C C A. Combustion Components Associates, Inc. C C A Combustion Components Associates, Inc. www.cca-inc.net About CCA CCA is a global provider of combustion control technologies to reduce NOx, particulate matter (PM), unburned carbon and CO emissions

More information

Converting to Natural Gas for MATs Compliance August 7, 2014

Converting to Natural Gas for MATs Compliance August 7, 2014 Converting to Natural Gas for MATs Compliance August 7, 2014 Presented by R. Gifford Broderick CCA Combustion Systems a Division of Peerless Mfg. 884 Main Street, Monroe, Connecticut 06468 Tel: (203) 268-3139

More information

Emission Reduction Program (ERP) For Existing Pulverized Fuel Fired Thermal Power Plants

Emission Reduction Program (ERP) For Existing Pulverized Fuel Fired Thermal Power Plants Emission Reduction Program (ERP) For Existing Pulverized Fuel Fired Thermal Power Plants Stochiometric combustion through Coal Mass Flow Balancing & Online Unburnt Carbon In Ash Measurement Anup Shukla

More information

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow Year 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Oct-16 Nov-16 Dec-16 Jan-17 Feb-17 Mar-17 Apr-17 May-17 Jun-17 Jul-17 Aug-17 Sep-17 Oct-17 2,038 2,922 4,089 4,349 6,256 7,124 8,885 8,885 8,885 8,885 8,885 8,885 9,107

More information

IED RELATING TO OIL AND GAS BURNERS FOR INDUSTRIAL USE

IED RELATING TO OIL AND GAS BURNERS FOR INDUSTRIAL USE IED RELATING TO OIL AND GAS BURNERS FOR INDUSTRIAL USE Nigel Webley Group Technical Director Hamworthy Combustion Tel: 01202 662754 E-mail: nwebley@hamworthy-combustion.com Website: www.hamworthy-combustion.com

More information

Table 2. NOx Control for Stoker-fired Industrial Boilers (Bituminous or Sub-bituminous Coal) (WDNR 1989) Control Techniques NOx Reduction Percent Commercial Availability and Comments FGR 40 to 45 Available.

More information

2001 Conference on SCR and SNCR

2001 Conference on SCR and SNCR 2001 Conference on SCR and SNCR First Year's Operating Experience with SCR on 600MW PRB Fired Boiler May 17, 2001 New Madrid SCR Retrofit Project Overview Unit 2 Base Award (6/98); Unit 1 Option Award

More information

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung Dr.-Ing. Marco Derksen Contents NOx formation In-furnace NOx reducing measures Application of premixed combustion Experiences in

More information

OPERATIONAL CRITERIA AND BURNER MODIFICATIONS FOR ACHIEVING LOW LOAD UNSUPPORTED COAL FIRING ON TANGENTIAL AND WALL-FIRED UNITS

OPERATIONAL CRITERIA AND BURNER MODIFICATIONS FOR ACHIEVING LOW LOAD UNSUPPORTED COAL FIRING ON TANGENTIAL AND WALL-FIRED UNITS OPERATIONAL CRITERIA AND BURNER MODIFICATIONS FOR ACHIEVING LOW LOAD UNSUPPORTED COAL FIRING ON TANGENTIAL AND WALL-FIRED UNITS PRESENTED AT: RMEL Steam Generation Cycling Symposium June, 14, 2018 Omaha,

More information

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies: Airejet Low NOx Coal Burner Unique low NO X coal burner with center air jet for use with overfire air (OFA) systems. Sleeve Damper Actuator Core Air Inlet Duct and Damper Pitot Grid Outer Spin Vanes Inner

More information

MECHANISM OF NOx CONTROL

MECHANISM OF NOx CONTROL MECHANISM OF NOx CONTROL SC/EEC Seminar/22 nd April,2016 1 2. Concept MECHANISM OF NOx CONTROL NOx generation in the coal fired boiler? Thermal NOx and Fuel NOx are the main factors of NOx generation...

More information

John Zink # United Kingdom

John Zink # United Kingdom John Zink Company, LLC Table of Contents Low NOx Solutions for Industrial Boiler Applications John Zink Company Overview Markets Served TODD Products & Technologies Case Studies William Testa Director

More information

NOx Emission Control Options for ICI Boilers

NOx Emission Control Options for ICI Boilers NOx Emission Control Options for ICI Boilers Advances in Air Pollution Control Maryland Department of the Environment May 18-19, 2011 John M. Boyle, Ph.D. Senior Director, Technology Development Fuel Tech,

More information

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS* COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates For Internal Use Only. FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year

More information

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS* COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year Jan Feb Mar Apr May Jun

More information

2007 Chevron and John Zink Company, LLC

2007 Chevron and John Zink Company, LLC Session 10 Thursday, December 7, 8:00-9:30 NOx Reduction Implementation Technology Plant-wide NOx Reduction Strategies: Chevron John Zink Experience Ed Shepherd, Chevron (Richmond, CA) Jim Seebold,, retired

More information

Combustion Optimization of Panshan Unit 4 for Energy Savings & NO x Emissions Reduction

Combustion Optimization of Panshan Unit 4 for Energy Savings & NO x Emissions Reduction Combustion Optimization of Panshan Unit 4 for Energy Savings & NO x Emissions Reduction A&WMA International Specialty Conference May 10-14, 2010 Xi'an, Shaanxi Province, China Energy Research Center, Lehigh

More information

Achieving Ultra Low NO x Emissions in Boiler Burner Retrofits. Bill Gurski Rex Isaacs John Guarco

Achieving Ultra Low NO x Emissions in Boiler Burner Retrofits. Bill Gurski Rex Isaacs John Guarco Achieving Ultra Low NO x Emissions in Boiler Burner Retrofits Bill Gurski Rex Isaacs John Guarco Retrofits Success is in the details When it comes to retrofits, details provide the roadmap to success:

More information

Steinmüller Engineering GmbH POWER-GEN Europe, Vienna

Steinmüller Engineering GmbH POWER-GEN Europe, Vienna Steinmüller Engineering GmbH 2013-06-06 POWER-GEN Europe, Vienna Combustion optimisation, efficiency improvements and emission reduction by installation of modern LowNO x firing systems at existing bituminous

More information

Power Generation Flexibilisation Case Studies from Germany. By Ronald Rost & Arun Kumar Sarna

Power Generation Flexibilisation Case Studies from Germany. By Ronald Rost & Arun Kumar Sarna Power Generation Flexibilisation Case Studies from Germany By Ronald Rost & Arun Kumar Sarna Agenda About VPC & Encotec Moorburg Flexibilisation flexgen Jaenschwalde 2 VPC GmbH Flexibilisation case studies

More information

Worldwide Pollution Control Association

Worldwide Pollution Control Association Worldwide Pollution Control Association IL Regional Technical Seminar September 13-15,211 Visit our website at www.wpca.info Babcock Power Inc. The Future Of Coal Fired SCRs In A Carbon Capture World 211

More information

Methanol As Low Cost Alternative Fuel For Emission Reduction In Gas Turbines and Utilities Boilers

Methanol As Low Cost Alternative Fuel For Emission Reduction In Gas Turbines and Utilities Boilers Methanol As Low Cost Alternative Fuel For Emission Reduction In Gas Turbines and Utilities Boilers IEC and Dor Chemicals Jan 13 th, 2013 Weizman Institute of Science, Rehovot, Israel 1 Organization Chart

More information

Retrofitting of Mitsubishi Low NOx System

Retrofitting of Mitsubishi Low NOx System 111 Retrofitting of Mitsubishi Low NOx System Susumu Sato *1 Yoshinori Kobayashi *1 Takao Hashimoto *2 Masahiko Hokano *2 Toshimitsu Ichinose *3 (MHI) has long been engaged in low NOx combustion R & D

More information

Workshop I. Tuning LNB s and OFA Systems

Workshop I. Tuning LNB s and OFA Systems Workshop I Tuning LNB s and OFA Systems R. Thompson FERCo, Laguna Hills, CA 29 Reinhold NO x Roundtable Cleveland, Ohio February, 29 1 REQUIREMENTS FOR EFFECTIVE NO X OPTIMIZATION Comprehensive Diagnostic

More information

First Correlating Revision No. 1-NFPA [ Section No ]

First Correlating Revision No. 1-NFPA [ Section No ] First Correlating Revision No. 1-NFPA 85-2013 [ Section No. 3.3.52.1 ] 3.3.52.1 Booster Fan. A device fan used to assist in the supply of air to, or the removal of flue gas products from, the combustion

More information

Making Electricity since December Melody Collis Facilities Engineering Assistant Manager Toyota Motor Manufacturing Canada

Making Electricity since December Melody Collis Facilities Engineering Assistant Manager Toyota Motor Manufacturing Canada Making Electricity since December 2015 Melody Collis Facilities Engineering Assistant Manager Toyota Motor Manufacturing Canada Cambridge 1 Company Culture Vision Woodstock TMMC's goal is to maintain a

More information

OPTIMIZING THE BOILER COMBUSTION PROCESS IN A COAL FIRED POWER PLANT UTILIZING FUZZY NEURAL MODEL TECHNOLOGY

OPTIMIZING THE BOILER COMBUSTION PROCESS IN A COAL FIRED POWER PLANT UTILIZING FUZZY NEURAL MODEL TECHNOLOGY OPTIMIZING THE BOILER COMBUSTION PROCESS IN A COAL FIRED POWER PLANT UTILIZING FUZZY NEURAL MODEL TECHNOLOGY AUTHORS Harry R. Winn George M. Bolos, P.E. Senior Optimization Engineer Principal Engineer

More information

The New Coen Micro-NOx

The New Coen Micro-NOx COEN The New THE COST-EFFECTIVE SOLUTION FOR FIRETUBE & INDUSTRIAL BURNER APPLICATIONS FOR TODAY S TOUGH APPLICATIONS THE NEW MICRO-NOX SOLUTION Performance Coen s New Micro-NOx burner is specifically

More information

Boiler Fuel Firing System

Boiler Fuel Firing System Boiler Fuel Firing System COMBUSTION Everywhere, at all times, oxygen combines with other elements. This general process is called Oxidation Burning, or Combustion, is a special form of oxidation: - Oxygen

More information

Building 65 Pellet Fired Steam Plant

Building 65 Pellet Fired Steam Plant Building 65 Pellet Fired Steam Plant Bar Harbor, ME By Norm Burdzel, PE Facilities Engineer, The Jackson Laboratory Tony Davis, PE Mechanical Engineer, Allied Engineering JAX Oil Load, 1.6M GPY 14000 12000

More information

Chapter 5 Oxygen Based NOx Control

Chapter 5 Oxygen Based NOx Control Chapter 5 Oxygen Based NOx Control Editor s Note: Chapter 5 is written by Dr. Brian Doyle and is drawn primarily from personal knowledge and the material developed for the NOx Emissions course offered

More information

SGT5-8000H/SCC5-8000H 1S. First experience of Commercial Operation at Irsching 4. Russia Power Moscow, March

SGT5-8000H/SCC5-8000H 1S. First experience of Commercial Operation at Irsching 4. Russia Power Moscow, March SGT5-8000H/SCC5-8000H 1S First experience of Commercial Operation at Irsching 4 Russia Power Moscow, March 5 2012 Armin Städtler R&D Program Manager 8000H 8000H Overview Validation Status Summary Fig.

More information

TECHNICAL PUBLICATION

TECHNICAL PUBLICATION TECHNICAL PUBLICATION Reducing NO X Emissions and Commissioning Time on Southern Company Coal Fired Boilers With Low NO X Burners and CFD Analysis by Bonnie Courtemanche, P.E. Darrell Dorman Ali Yilmaz,

More information

Boiler Optimization and MATS Work Practices Requirements. McIlvaine Hot Topics September 27 th, 2013

Boiler Optimization and MATS Work Practices Requirements. McIlvaine Hot Topics September 27 th, 2013 Boiler Optimization and MATS Work Practices Requirements McIlvaine Hot Topics September 27 th, 2013 Mercury and Air Toxics Standard (MATS) Requires all plants to reduce mercury and increase efficiency

More information

Case Study. Modernising gas fired power plant boiler damper drives and damper bearings

Case Study. Modernising gas fired power plant boiler damper drives and damper bearings Case Study Modernising gas fired power plant boiler damper drives and damper bearings Boiler Damper Drives & Bearings Modernisation Case Study - 10th December 2014 Boiler Damper Drives & Bearings Modernisation

More information

CONTROLS UPGRADE CASE STUDY FOR A COAL-FIRED BOILER

CONTROLS UPGRADE CASE STUDY FOR A COAL-FIRED BOILER CONTROLS UPGRADE CASE STUDY FOR A COAL-FIRED BOILER ABSTRACT This paper discusses the measures taken to upgrade controls for a coal-fired boiler which was experiencing problems with primary air flow, furnace

More information

UPDATED LOW NOx COMBUSTION TECHNOLOGIES FOR BOILERS, 2003

UPDATED LOW NOx COMBUSTION TECHNOLOGIES FOR BOILERS, 2003 UPDATED LOW NOx COMBUSTION TECHNOLOGIES FOR BOILERS, 2003 Takanori Yano, Kaz Sakai, Kenji Kiyama, Osamu Okada, Kenichi Ochi, Babcock-Hitachi K.K., Kure Division, Boiler Design Department, 6-9 Takara-machi

More information

ZEECO BURNER DIVISION

ZEECO BURNER DIVISION ZEECO BURNER DIVISION Enhanced Jet Flat Flame Burners GLSF Series 22151 EAST 91ST STREET BROKEN ARROW OK 74014 USA +1-918-258-8551 SALES@ZEECO.COM ZEECO.COM INTRODUCTION: This document discusses the advantages

More information

Legislation in the European Union and the impact on existing plant

Legislation in the European Union and the impact on existing plant Legislation in the European Union and the impact on existing plant Lesley Sloss FRSC FIEnvSci Principal Environmental Consultant lesleysloss@gmail.com Current EU legislation EU member countries must comply

More information

Design Features and Commissioning of the 700 MW Coal-Fired Boiler at the Tsuruga Thermal Power Station No. 2

Design Features and Commissioning of the 700 MW Coal-Fired Boiler at the Tsuruga Thermal Power Station No. 2 106 Design Features and Commissioning of the 700 MW Coal-Fired Boiler at the Tsuruga Thermal Power Station No. 2 Susumu Sato *1 Masahiko Matsuda *1 Takao Hashimoto *2 Yoshiyuki Wakabayashi *2 Akira Hashimoto

More information

TriOx Triple Air Staged Ultra Low NOx Burner

TriOx Triple Air Staged Ultra Low NOx Burner Triple Air Staged Ultra Low NOx Burner TriOx-1 Edition 09-08 Ultra low NOx emissions of 20 ppm or less Invisiflame mode offers positive UV flame supervision throughout entire operating range for excellent

More information

A&WMA, CA SCAQMD, Diamond Bar, CA. Challenges for Meeting New Lower Air Emissions

A&WMA, CA SCAQMD, Diamond Bar, CA. Challenges for Meeting New Lower Air Emissions A&WMA, CA SCAQMD, Diamond Bar, CA. Challenges for Meeting New Lower Air Emissions September 21, 2017 Wayne Jones, Business Development Manager wsj@topsoe.com AGENDA New Products Dual functions SCR/CO/VOC

More information

IMPROVEMENT OF COAL-FIRED GENERATION UNITS AT LAMMA POWER STATION FOR NOx EMISSION CONTROL

IMPROVEMENT OF COAL-FIRED GENERATION UNITS AT LAMMA POWER STATION FOR NOx EMISSION CONTROL IMPROVEMENT OF COAL-FIRED GENERATION UNITS AT LAMMA POWER STATION FOR NOx EMISSION CONTROL ABSTRACT Francis Cho Ying Cheng and Henry Hin Wing Fung Director and General Manager (Generation) The Hongkong

More information

Low NOx Technology Seminar. The Gas Company April 30 th, 2003 Downey,CA. Presentation Overview

Low NOx Technology Seminar. The Gas Company April 30 th, 2003 Downey,CA. Presentation Overview Low NOx Technology Seminar Sponsored by The Gas Company April 30 th, 2003 Downey,CA David Thornock Presentation Overview Who is Overview of the FIR Burner Burner design Demonstrations and Installations

More information

California s Success in Controlling Large Industrial Sources

California s Success in Controlling Large Industrial Sources California s Success in Controlling Large Industrial Sources Endicott House 2006 Symposium Mike Scheible Deputy Executive Officer California Air Resources Board California Environmental Protection Agency

More information

GASCO Habshan SRUs - Challenges of Operation. Abdulkader Ahmed Al Kasem, Jumaa Al Marzouqi

GASCO Habshan SRUs - Challenges of Operation. Abdulkader Ahmed Al Kasem, Jumaa Al Marzouqi GASCO Habshan SRUs - Challenges of Operation Abdulkader Ahmed Al Kasem, Jumaa Al Marzouqi 1 General Overview Habshan Overview Configuration of GASCO Habshan SRUs Challenges of Operation 1- Feed Quality

More information

Eclipse Vortometric Burners Series HI

Eclipse Vortometric Burners Series HI Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas)

More information

MSU Mankato and Ameresco. GESP Project. August 29, Ameresco, Inc. 2017, All Rights Reserved

MSU Mankato and Ameresco. GESP Project. August 29, Ameresco, Inc. 2017, All Rights Reserved MSU Mankato and Ameresco GESP Project August 29, 2017 Agenda Campus Utility Baseline GESP Review and Summary Sustainability Overview Energy Savings Achieved Overview of the Project Time Table Financial

More information

Diagnostic Tools for Gas Turbine CO and SCR Systems

Diagnostic Tools for Gas Turbine CO and SCR Systems Diagnostic Tools for Gas Turbine CO and SCR Systems L. J. Muzio, R. A. Smith Fossil Energy Research Corp. Laguna Hills, CA Reinhold 216 NO x -Combustion Round Table February 1, 216 Orlando, Florida Simple

More information

: Nubaria Module III - Egypt (2x250MW GE gas turbines frame 9 FA)

: Nubaria Module III - Egypt (2x250MW GE gas turbines frame 9 FA) 103956-MEC-CMOS-E-2000 Gas Turbine Maintenance Engineer Holds a B. Sc. in Mechanical Power Engineering and has over 14 years hands-on experience working in construction, maintenance, operation, commissioning

More information

Economics of Integrating Renewables DAN HARMS MANAGER OF RATE, TECHNOLOGY & ENERGY POLICY SEPTEMBER 2017

Economics of Integrating Renewables DAN HARMS MANAGER OF RATE, TECHNOLOGY & ENERGY POLICY SEPTEMBER 2017 Economics of Integrating Renewables DAN HARMS MANAGER OF RATE, TECHNOLOGY & ENERGY POLICY SEPTEMBER 2017 Presentation Outline Understanding LPEA s expenses and what drives them Economics of net metering

More information

NJ Solar Market Update As of 6/30/15

NJ Solar Market Update As of 6/30/15 NJ Solar Market Update As of 6/30/ Prepared by Charlie Garrison July 17, 20 SOLAR INSTALLED CAPACITY DATA The preliminary installed solar capacity as of 6/30/ is approximately 1,500.7 MW. Approximately

More information

Unit Design Data. Gas Turbine or Jet Engine (Voluntary Reporting)

Unit Design Data. Gas Turbine or Jet Engine (Voluntary Reporting) Unit Design Data Gas Turbine or Jet Engine (Voluntary Reporting) (Note: The NERC Board of Trustees approved the GADS Task Force report (dated July 20, 2011 i, which states that design data collection outside

More information

Coal Fired Boilers. Technologies for Improved Efficiency & Reduced Emissions. C.Jayadevan Bharat Heavy Electriclas Ltd. Tiruchirappalli, India

Coal Fired Boilers. Technologies for Improved Efficiency & Reduced Emissions. C.Jayadevan Bharat Heavy Electriclas Ltd. Tiruchirappalli, India Coal Fired Boilers Technologies for Improved Efficiency & Reduced Emissions C.Jayadevan Bharat Heavy Electriclas Ltd. Tiruchirappalli, India Power Generation Options Hydro Thermal Nuclear Non Conventional

More information

Lecture 7a: Large Scale Oxyfuel Demonstrations. G Hesselmann APP OFWG Capacity Building Course 5 th & 6 th February 2009, Daejeon, Korea

Lecture 7a: Large Scale Oxyfuel Demonstrations. G Hesselmann APP OFWG Capacity Building Course 5 th & 6 th February 2009, Daejeon, Korea Lecture 7a: Large Scale Oxyfuel Demonstrations G Hesselmann APP OFWG Capacity Building Course 5 th & 6 th February 2009, Daejeon, Korea Large Scale Demonstrations Significant Projects A Selection of Coal-Fired

More information

BENCHMARKING SO 3 REMOVAL THE CLEANSTACK PROCESS

BENCHMARKING SO 3 REMOVAL THE CLEANSTACK PROCESS BENCHMARKING SO 3 REMOVAL THE CLEANSTACK PROCESS Ms. Amy P Evans* Director of Technology, Marsulex Environmental Technologies Inc. LLC, 200 North Seventh Street, Lebanon, PA 17046 Mr. Joseph A. Gresh Senior

More information

IPB-MI ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL MINING AND MINERAL INDUSTRIES

IPB-MI ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL MINING AND MINERAL INDUSTRIES IPB-MI R ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL MINING AND MINERAL INDUSTRIES 1 Beck drives are built to last even in highly abusive conditions Beck drives have been providing accurate and reliable

More information

Commercial Operating Experience on an Activated Carbon Injection System

Commercial Operating Experience on an Activated Carbon Injection System Commercial Operating Experience on an Activated Carbon Injection System Paper #08-A-170-Mega-AWMA Travis Starns, Cameron Martin ADA Environmental Solutions 8100 SouthPark Way, Unit B Littleton, CO 80120

More information

West Campus Power Plant

West Campus Power Plant West Campus Power Plant Tabular Report The University of Iowa Iowa City, IA Final August 2009 Executive Summary As new facilities are located on the West Campus, the utility load increases and additional

More information

Plasma Ignition and Combustion Stabilizing System (PICS)

Plasma Ignition and Combustion Stabilizing System (PICS) S&S Plasma Ignition and Combustion Stabilizing System (PICS) A Fuel Oil Saving Technology for Coal Fired Power Plant By Yantai Longyuan Power Technology Co., Ltd Associate Partner Contents Yantai Longyuan

More information

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12) VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 74.15.1 - BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12) A. Applicability The provisions of this

More information

Emissions Legislation

Emissions Legislation Emissions Legislation Potential Impact of the Medium Combustion Plant Directive 1 SAACKE Presentation All rights reserved by SAACKE Combustion Services Ltd, UK and SAACKE GmbH, Bremen The formation of

More information

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone: Building project SDC Example Dyfi Eco Park SY20 8AX Machynlleth UK Contact person: Mr C. Laughton Phone: 01654 700324 E-Mail: software@solardesign.co.uk Results of annual simulation Installed collector

More information

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006) RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006) 1.0 Purpose The purpose of this rule is to limit emissions

More information

TECHNICAL PUBLICATION

TECHNICAL PUBLICATION TECHNICAL PUBLICATION Efficient, Low Emissions and Fuel Flexible Today s Stoker-Fired Biomass Systems Technology by Kevin Toupin Director, Boiler Equipment Riley Power Inc. Presented at International Biomass

More information

TEPCO s Emission Control Measures (in Thermal Power Plants) September 7, 2013 Toyoto Matsuoka Tokyo Electric Power Company (TEPCO) 东京电力公司

TEPCO s Emission Control Measures (in Thermal Power Plants) September 7, 2013 Toyoto Matsuoka Tokyo Electric Power Company (TEPCO) 东京电力公司 All Rights Reserved 2013 Tokyo Electric Power Company, Inc. TEPCO s Emission Control Measures (in Thermal Power Plants) September 7, 2013 Toyoto Matsuoka Tokyo Electric Power Company (TEPCO) 东京电力公司 Contents

More information

TEMINOX GLS. Mono-/Duoblock Pressure Jet. Advantages. Capacity range Fuels

TEMINOX GLS. Mono-/Duoblock Pressure Jet. Advantages. Capacity range Fuels Mono-/Duoblock Pressure Jet TEMINOX GLS Advantages Highest quality standard by latest state of production engineering, application of ISO 9001 quality management system European type approval (EN 267 /

More information

DENSIFIED REFUSE DERIVED FUEL CO-FIRING EXPERIENCE IN U.S. AIR FORCE SPREADER STOKER BOILERS

DENSIFIED REFUSE DERIVED FUEL CO-FIRING EXPERIENCE IN U.S. AIR FORCE SPREADER STOKER BOILERS DENSIFIED REFUSE DERIVED FUEL CO-FIRING EXPERIENCE IN U.S. AIR FORCE SPREADER STOKER BOILERS ALFRED W. JOENSEN Department of Mechanical Engineering Iowa State University DOUGLAS FISCUS Midwest Research

More information

Industrial Boiler MACT HCL/PM Control with Wet Scrubbing / Wet ESP Control Technology"

Industrial Boiler MACT HCL/PM Control with Wet Scrubbing / Wet ESP Control Technology McIlvaine Webinar : 4/4/13 Industrial Boiler MACT HCL/PM Control with Wet Scrubbing / Wet ESP Control Technology" Buzz Reynolds VP Wet ESP Siemens Page 1 Industrial Boiler NESHAP Rule Issued: January 31,

More information

Craig A. Penterson Senior Staff Engineer Fuel Equipment Design Riley Stoker Corporation

Craig A. Penterson Senior Staff Engineer Fuel Equipment Design Riley Stoker Corporation CONTROLLING NOX EMISSIONS TO MEET THE 1990 CLEAN AIR ACT by Craig A. Penterson Senior Staff Engineer Fuel Equipment Design Riley Stoker Corporation Presented at the International Joint Power Generation

More information

Vasilikos Power Station

Vasilikos Power Station Vasilikos Power Station General Vasilikos Power Station constitutes the biggest work of infrastructure ever undertaken in Cyprus. Phase I of the station is in commercial operation since the year 2000.

More information

Emission Control Technology for Stationary Diesel Engines

Emission Control Technology for Stationary Diesel Engines Emission Control Technology for Stationary Diesel Engines Rasto Brezny September 13, 2013 Manufacturers of Emission Controls Association www.meca.org www.dieselretrofit.org Outline Compliance Challenges

More information

Alternative Fuels Can Significantly Reduce Costs

Alternative Fuels Can Significantly Reduce Costs 2006 Forum on Energy: Immediate Solutions, Emerging Technologies May 15-17 Appleton, WI Alternative Fuels Can Significantly Reduce Costs Three Case Studies Presented by: David F. Seitz, P.E. Project Director

More information

Kapaia Power Station (KPS) Feasibility Study of Simple-Cycle GE LM2500-PH GT Conversion to Methanol Firing

Kapaia Power Station (KPS) Feasibility Study of Simple-Cycle GE LM2500-PH GT Conversion to Methanol Firing Kapaia Power Station (KPS) Feasibility Study of Simple-Cycle GE LM2500-PH GT Conversion to Methanol Firing November, 2013 Table of contents 1. Executive Summary 2. Simple-Cycle LM2500-PH GT operation mode

More information

Environmental Retrofits: Costs and Supply Chain Constraints

Environmental Retrofits: Costs and Supply Chain Constraints Environmental Retrofits: Costs and Supply Chain Constraints Presented at MISO Annual Stakeholders Meeting Indiana Presented by Metin Celebi The Brattle Group June 20, 2012 Copyright 2012 The Brattle Group,

More information

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Industrial Combustion offers complete boiler

More information

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX Particulate Control O&M Training APC/PCUG Conference July 12-16, 2009 The Woodlands, TX The Ultimate ESP Rebuild: Casing Conversion to a Pulse Jet Fabric Filter, a Case Study By Tom Lugar Buell APC, Fisher-Klosterman

More information

OPTIMIZING THE COMBUSTION PROCESS IN A COAL FIRED POWER PLANT REDUCES NOX BEYOND GUARANTEE LEVEL

OPTIMIZING THE COMBUSTION PROCESS IN A COAL FIRED POWER PLANT REDUCES NOX BEYOND GUARANTEE LEVEL OPTIMIZING THE COMBUSTION PROCESS IN A COAL FIRED POWER PLANT REDUCES NOX BEYOND GUARANTEE LEVEL AUTHORS Vasu V. Vasudevan Senior Optimization Engineer Emerson Process Management - Power and Water Solutions

More information

NO TROUBLE WITH NOx AN ADVANCED CONCEPT FOR EFFECTIVE NO X REDUCTION

NO TROUBLE WITH NOx AN ADVANCED CONCEPT FOR EFFECTIVE NO X REDUCTION NO TROUBLE WITH NOx AN ADVANCED CONCEPT FOR EFFECTIVE NO X REDUCTION 1 NOx FORMATION AND ABATEMENT: SOLUTIONS FOR < 200 mg/nm 3 NOx EMISSIONS THE DRIVERS In addition to the formation by the nitrogen NOx

More information

A214396F78F5E4B92DB85A8D15EFBBC #2.ECT0223b.xls

A214396F78F5E4B92DB85A8D15EFBBC #2.ECT0223b.xls From: To: Cc: Bcc: Subject: Date: Attachments: Aiken, Sam Larua Fanelli Fitzsimmons, Casey McHugh, Sean

More information

Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97

Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97 RULE 425.2 Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97 I. Purpose The purpose of this Rule is to limit oxides of nitrogen (NOx) emissions

More information

Doing more for clean environment and energy saving

Doing more for clean environment and energy saving Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one

More information

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. PROFIRE D Series burners 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Cleaver-Brooks offers complete boiler

More information

MEC-CM-E-2001 Lead Mechanical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

MEC-CM-E-2001 Lead Mechanical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS 101288-MEC-CM-E-2001 Lead Mechanical Engineer Holds a B. Sc. in Mechanical Engineering and has about 15 years hands-on experience working in construction and maintenance at Power Plants and other projects.

More information

Presented at 1996 AFRC International Symposium, Baltimore, Maryland, September 1996 Development of a High Performance Versatile Low NOx Burner

Presented at 1996 AFRC International Symposium, Baltimore, Maryland, September 1996 Development of a High Performance Versatile Low NOx Burner Presented at 1996 AFRC International Symposium, Baltimore, Maryland, September 1996 Development of a High Performance Versatile Low NOx Burner Vladimir Lifshits Coen, Inc. 1510 Rollins Road, Burlingame,

More information

INSTALLATION OF THE POWER INDUSTRY S FIRST COMMERCIAL ALTA SYSTEM FOR NO X CONTROL AT AMEREN S SIOUX PLANT

INSTALLATION OF THE POWER INDUSTRY S FIRST COMMERCIAL ALTA SYSTEM FOR NO X CONTROL AT AMEREN S SIOUX PLANT INSTALLATION OF THE POWER INDUSTRY S FIRST COMMERCIAL ALTA SYSTEM FOR NO X CONTROL AT AMEREN S SIOUX PLANT ABSTRACT Marc Cremer, Andrew Chiodo Reaction Engineering International Salt Lake City, UT 84101

More information

High SO 2 Removal Performance using Limestone FGD at Tusimice Power Plant

High SO 2 Removal Performance using Limestone FGD at Tusimice Power Plant 98,3% Desulphurisation Efficiency High SO 2 Removal Performance using Limestone FGD at Tusimice Power Plant Speaker: Klaus Bärnthaler, Franz Hafner, Jan Stancl CLEAN ENERGY SOLUTIONS Date of presentation

More information

Impact of Delhi s CNG Program on Air Quality

Impact of Delhi s CNG Program on Air Quality Impact of Delhi s CNG Program on Air Quality Urvashi Narain Presentation at Transport, Health, Environment, and Equity in Indian Cities Conference at Indian Institute of Technology, New Delhi December

More information

Refining Fitness Check Concawe Step 2 data Highlights

Refining Fitness Check Concawe Step 2 data Highlights ENVIRONMENTAL SCIENCE FOR THE EUROPEAN REFINING INDUSTRY Refining Fitness Check Concawe Step 2 data Highlights Concawe Symposium Brussels 24 February 2015 C. Caiado, Research Associate Concawe data collection

More information

Boiler Burners For Commercial And Industrial Applications

Boiler Burners For Commercial And Industrial Applications Boiler Burners For Commercial And Industrial Applications Webster Combustion Is Committed To Better Fuel Economy, Energy Savings And Reliability For Boiler Burners. Webster is a leading manufacturer of

More information

ANNEX A-5 GAS TURBINE JET ENGINE EXPANDER TURBINE STEAM TURBINE GENERATOR

ANNEX A-5 GAS TURBINE JET ENGINE EXPANDER TURBINE STEAM TURBINE GENERATOR ANNEX A-5 UNITS IN COMBINED CYCLE or CO-GENERATION BLOCKS INDEX TO SYSTEM/COMPONENT CAUSE CODES Inlet Air System and Compressors 5000-5039 Fuel, Ignition and Combustion Systems 5040-5079 Turbine 5080-5099

More information

Refrigeration Screw Compressor Controller Introduction

Refrigeration Screw Compressor Controller Introduction Refrigeration Screw Compressor Controller Introduction Portland, Oregon June 28, 2017 Doug Scott VaCom Technologies Topics New Controller Introduction Suction Group Control VaCom Refrigeration Approach

More information

University of Michigan Eco-Driving Index (EDI) Latest data: October 2017

University of Michigan Eco-Driving Index (EDI)   Latest data: October 2017 University of Michigan Eco-Driving Index () http://www.ecodrivingindex.org Latest data: October 2017 Developed and issued monthly by Michael Sivak and Brandon Schoettle Sustainable Worldwide Transportation

More information

Oil, Gas and Dual Fuel Monoblock Burners

Oil, Gas and Dual Fuel Monoblock Burners Capacity Oil, Gas and Dual Fuel Monoblock Burners 1-133 kw 1 Low Emission Combustion Technology Table of contents 2 Oilon Burners 8 Choosing the burner 9 NOx emissions 1 FGR - Flue Gas Recirculation 11

More information

Benefits of a Cooling Tower VFD Retrofit

Benefits of a Cooling Tower VFD Retrofit Benefits of a Cooling Tower VFD Retrofit Greg Owen Electrical Engineer Ryan Carlson Electrical Engineer 54 th Annual MIPSYCON Conference November 7, 2018 Agenda Project Introduction Project Development

More information

Alstom CFB boilers achieve high combustion efficiency with challenging discarded coal. Hugh Kennedy 16 th July 2013

Alstom CFB boilers achieve high combustion efficiency with challenging discarded coal. Hugh Kennedy 16 th July 2013 Alstom CFB boilers achieve high combustion efficiency with challenging discarded coal Hugh Kennedy 16 th July 2013 Agenda Baima 300 MWe CFB demonstration plant Page 3 Emile Huchet 125 MWe captive power

More information

1070 SERIES ULTRA LOW NO X

1070 SERIES ULTRA LOW NO X CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing

More information

Monthly Operating Report. September 2016

Monthly Operating Report. September 2016 Monthly Operating Report September 20 September overview» For the month of September 20 Contact recorded: Electricity, gas and steam sales of 819 GWh (September 2015: 821 GWh) Netback of $79.50/MWh (September

More information

An ISO 9001 company IPB-AL ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL ALUMINUM INDUSTRY. BECK VIDEO Scan w/ Smartphone

An ISO 9001 company IPB-AL ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL ALUMINUM INDUSTRY. BECK VIDEO Scan w/ Smartphone IPB-AL An ISO 9001 company R ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL ALUMINUM INDUSTRY BECK VIDEO Scan w/ Smartphone Rugged & Dependable with Consistently Precise Control in Demanding Applications

More information

ICI Boiler NOx & SO 2

ICI Boiler NOx & SO 2 ICI Boiler NOx & SO 2 Control Cost Estimates Andrew M. Bodnarik NH Department of Environmental Services OTC Committee Meeting Modeling/Stationary & Area/Mobile Sources Niagara Falls, NY September 3, 2009

More information