HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3

Size: px
Start display at page:

Download "HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3"

Transcription

1 Page 1 of 7 HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT SULPHUR BLOCK PART V SECTION 3.3 STANDARD SPECIFICATION FOR OIL MIST LUBRICATION SYSTEM DOCUMENT NO : 44LK /M.02/0024/A4 Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 21-May-09 7 Issued for FEED SBN PDB SNG

2 HPCL, MUMBAI Standard specification PART V SULPHUR BLOCK for Oil mist lubrication system SECTION : LK-5100 Doc No.: 44LK /M.02/0024/A4 Page 2 of 7 TABLE OF CONTENTS 1.0 SCOPE GENERAL requirements INSPECTION AND TESTING PACKING DOCUMENTATION GUARANTEE 7

3 PART V Standard specification HPCL, MUMBAI SECTION : 3.3 for Oil mist lubrication system SULPHUR BLOCK Page 3 of 7 Doc No.: 44LK /M.02/0024/A4 44LK SCOPE This specification lists technical requirements for Closed loop oil mist lubrication system to be provided for the project. 2.0 GENERAL REQUIREMENTS 2.1 All pumps in unit, except forced/ pressurized lubricated pumps, shall be provided with closed loop oil mist lubrication system by the LSTK Contractor. 2.2 Centralized oil mist lubrication for all pumps and motors shall be provided. 2.3 All piping / tubing for conveying oil mist shall be of SS The system shall be provided suitable for the hazardous area classification. 2.5 All auxiliaries and instrumentation necessary for smooth and trouble free operation of the oil mist lubrication system shall be provided. 2.6 An closed-loop centralized lubrication system designed to produce, transport and deliver oil mist from a central console to supply bearing lubrication for the pumps and drivers shall be provided. 2.7 Oil mist system vendor to advise number of console/generators based on total number of users and plot layout. 2.8 The oil mist lubrication system provided by the contractor shall include the following as a minimum: - Console/Generator with auxiliary back-up unit and demisting apparatus - Microprocessor controller to monitor operating variables - Mist manifold (one for each pump) - Mist reclassifiers (one for each lubrication point) - Condensed oil mist collection container (one per equipment set) - Oil return header to route recovered oil to oil receiver - Hand pump for each condensed oil mist collection container to transfer collected oil to return header - Necessary piping for transfer of oil from hand pump to return header - Oil receiver of adequate capacity to hold oil recovered from all oil mist collection containers. Oil receiver shall be provided with drain arrangement to collect oil to be drained in portable containers. - Oil purification system including pump, filter and other necessary equipment. The system to be designed such that purified oil can be recycled to oil mist lubrication system.

4 HPCL, MUMBAI Standard specification PART V SULPHUR BLOCK for Oil mist lubrication system SECTION : LK-5100 Doc No.: 44LK /M.02/0024/A4 Page 4 of Console/Generator i) Console cabinet and oil reservoir (for main and auxiliary units) shall be constructed out of 304 SS. All console piping, tubing, tube fittings and mounting brackets shall be of 304 SS. ii) iii) iv) Console shall have a 304 SS sunscreen roof. No heating elements shall come into direct contact with the lubricating oil. The atomizing device, generator head, shall have an air bypass regulator to control mist density. v) The generator (mist) head shall provide 125% of the required airflow without exceeding the maximum capacity of the head. The head shall also be capable of proper misting operating down to 50% of rated flow. vi) vii) viii) vix) vx) vxi) The design of the mist head shall be such that its capacity can be changed without complete removal of the mist head from the console. Mist head shall include an air/oil heater. Console shall have an auxiliary back-up unit with the following: Oil mist generating capacity shall be equal to and of the same design as the main unit capable of operating independently from the main generating system provide a 10 micron oil filter easily accessible for maintenance. The oil reservoir of the main mist-generating chamber shall allow the system to operate for a minimum of 72 hours without refill. Oil reservoir shall include the following: - Level sight glass with normal operating level indicated - Fill connection with filtering screen - Tank vent - Low point drain - Low level probe - Temperature indicator - Pressure relief valve - Removable cover plate - Low point drain and valve - Low level alarm switch - Pressure gauge - Mist injection valve 2.10 Inlet Air System The inlet air system shall include the following: Filter/moisture separator Pressure regulator 2.11 Instrumentation

5 PART V Standard specification HPCL, MUMBAI SECTION : 3.3 for Oil mist lubrication system SULPHUR BLOCK Page 5 of 7 Doc No.: 44LK /M.02/0024/A4 44LK Oil mist vendor shall be responsible for supplying instrumentation to continuously monitor pressures, temperatures and oil levels. As a minimum the following variables shall be monitored: - Oil supply pressure - Supply air pressure - Regulated air pressure - Mist header pressure - Mist density - Air/oil temperature - Oil level in the mist-generating reservoir - Oil level in the bulk oil supply tank - Oil temperature in the bulk oil supply tank - Ambient temperature - The oil mist vendor shall provide a local control panel. Values for the above parameters shall be displayed on command on the panel Instruments and Safety Controls Alarm switches for low discharge pressure, low oil reservoir level, and high filter differential pressure shall be provided. The switches shall be explosion-proof dual switches. The switches shall be closed (energized) during normal operation. The contractor shall provide for local or remote annunciation of oil system alarms. Contractor is also responsible for confirming that all system electrical components are suitable for the hazardous area classification An annunciator with manual reset sequence shall be furnished by the Purchaser and located in the local control panel Provide an auxiliary relay connected to a common trouble alarm located in the control center. This auxiliary relay shall be activated by all alarms Piping All distribution piping and tubing shall be provided by EPC contractor Main headers shall be 2 inches (50 mm) galvanized steel pipe and shall not exceed 600 feet (180 meters) in length. The oil mist supply vendor shall insure that the time required for oil mist to reach the most distant point(s) on a header shall not exceed 5 minutes All headers shall be sloped continuously downward to the console at a minimum rate of 1/240. An auto drain leg shall be used when any portion of the header cannot be continuously sloped to the console due to obstructions There shall be no block valves in the header downstream of the switching valves that control the flow of mist from the mist generator Pockets shall be avoided Branch headers shall be 2 inch (50mm) stainless galvanized steel pipe Drop points shall be ¾ inch (19mm) stainless galvanized steel pipe and shall come off the top of the headers.

6 HPCL, MUMBAI Standard specification PART V SULPHUR BLOCK for Oil mist lubrication system SECTION : LK-5100 Doc No.: 44LK /M.02/0024/A4 Page 6 of Drop points shall be sloped downward towards the main or branch headers at the rate of 1/ Drop points shall terminate between 24 inches (60cm) and 48 inches (120cm) above and offset to the equipment to be lubricated. The drop leg should not interfere with access to the rotating equipment Drop points shall not have block valves Return header (for closed loop only) shall be parallel to and constructed of the same material as the main distribution header. 3.0 INSPECTION AND TESTING 3.1 All items and their parts shall be subjected to all mandatory tests and supplementary tests (wherever specified) and checks called for in the respective codes/standards/specification. 3.2 All items shall be stage wise inspected by 3 rd party inspection agency as per requirements 4.0 PACKING 4.1 All items shall be protected from rust, corrosion and mechanical damage during transportation, shipment, and storage, Rust preventive shall not be harmful to welding and shall be easily removable with a petroleum solvent. 4.2 End shall be suitably protected and the protectors shall be secured and tightly attached. 4.3 Part Nos are to be painted with an alkyd based paint. Lead based paints of stamping is prohibited. 4.4 Packing for imported items shall be seaworthy in wooden crates/cases with internal plastic envelopes and shall facilitate easy opening for dockside inspection. 5.0 DOCUMENTATION 5.1 AT OFFER STAGE Manufacturer s complete descriptive catalogue / literatures Accreditions/approvals of international agencies, for the subject item. List of deviations, the reasons thereof and the technical compatibility. 5.2 ALONGWITH DELIVERY Ten copies of manufacturer s Material Test Certificates (physical properties, chemical composition, heat treatment etc.) duty certified by inspection authority. Test support s for all mandatory as well as supplementary tests wherever specified. One soft copy on CD for all documents. 5.3 Any other drawings/document as required.

7 PART V Standard specification HPCL, MUMBAI SECTION : 3.3 for Oil mist lubrication system SULPHUR BLOCK Page 7 of 7 Doc No.: 44LK /M.02/0024/A4 44LK GUARANTEE Vendor shall guarantee that all items supplied shall conform to the settled requirements in all respects. Any items found defective shall be replaced by the supplier at his on cost and without any delay.

SPECIFICATIONS FOR MOTOR OPERATED VALVES

SPECIFICATIONS FOR MOTOR OPERATED VALVES Doc No: 254625-300-SP-INT-004 Rev: B Page 1 of 11 SPECIFICATIONS FOR MOTOR OPERATED VALVES Hindustan Petroleum Corporation Ltd Visakha Dispatch Station VR-ATP Area, Naval Base Post Visakhapatnam - 530

More information

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet. SHEET 1 OF 5 1.0 GENERAL & SCOPE 1.1 This specification covers the design, material, construction features, manufacture, inspection & testing, Painting and packing requirements of Spring Loaded Bypass

More information

TECHNICAL SPECIFICATIONS FOR STEEL PLATES

TECHNICAL SPECIFICATIONS FOR STEEL PLATES TECHNICAL SPECIFICATIONS FOR STEEL PLATES 1.0 SCOPE: HINDUSTAN PETROLEUM CORPORATION LTD., GRESHAM HOUSE This specification covers requirement for Carbon Steel Plates of Structural Quality as per IS: 2062

More information

Oilmist Lubrication Applications In Refineries- Installation & Maintenance Issues

Oilmist Lubrication Applications In Refineries- Installation & Maintenance Issues Oilmist Lubrication Applications In Refineries- Installation & Maintenance Issues N Laxman Deputy Manager- Maintenance-Rotary Hindustan Petroleum Corporation Limited Visakh Refinery ABSTRACT Oil mist lubrication

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

FEPL ENGINEERING. Oil Mist Lubrication Systems. Service Driven. Practical Innovations. FMC Series Model FMC 750

FEPL ENGINEERING. Oil Mist Lubrication Systems. Service Driven. Practical Innovations. FMC Series Model FMC 750 FEPL ENGINEERING Oil Mist Lubrication Systems FMC Series Model FMC 750 424 Raheja Arcade Sector 11, CBD Belapur, Navi Mumbai 400 614, Maharashtra, India P: +91 22 41560900 F: +91 22 41560990 FEPLENGINEERING.COM

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller DISCONTINUED PRODUCT CSI 15621 - Mainframe Cooling Systems 1.1 SUMMARY Liebert CSU3000 CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller GUIDE SPECIFICATIONS 1.0 GENERAL These specifications describe

More information

34-SDMS-01 SPECIFICATIONS FOR

34-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES

More information

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY Reso-not TM Damping System XCITE Owner s Manual 1502C HYDRAULIC POWER SUPPLY Xcite Systems Corporation 675 Cincinnati RDS Batavia - 1 Pike Cincinnati, Ohio 45245 Tel: (239) 980-9093 Fax: (239) 985-0074

More information

CENTAC C700 Start-Up Services

CENTAC C700 Start-Up Services CENTAC C700 Start-Up Services Notes: (1) This packet includes: (a) the Centac Start-up form used by the Field Technician during start-up services; (b) the Installation Planning Checklist that is used prior

More information

Rosemount 285 Annubar Pak-Lok Assembly

Rosemount 285 Annubar Pak-Lok Assembly Quick Installation Guide 0025-0100-02, Rev AA Pak-Lok 25 Annubar Rosemount 25 Annubar Pak-Lok Assembly Start Step 1: Location and Orientation Step 2: Drill Holes into Pipe Step 3: Weld Mounting Hardware

More information

SPECIFICATION OF TRUCK MOUNTED MOBILE OIL SPILL RECOVERY UNIT MOSRU Lts.

SPECIFICATION OF TRUCK MOUNTED MOBILE OIL SPILL RECOVERY UNIT MOSRU Lts. SPECIFICATION OF TRUCK MOUNTED MOBILE OIL SPILL RECOVERY UNIT MOSRU - 6000 Lts. GENERAL:- The Vehicle Mounted Suction Unit shall be robust in construction and shall be used to create a vacuum for syphoning

More information

MODEL 10LH SPECIFICATION

MODEL 10LH SPECIFICATION MODEL 10LH SPECIFICATION 1.0 General Specifications There will be furnished one (1) only Grind Hog TM Model 10LH Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a clockwise (standard)

More information

Technical Information Liquiline System CAT810

Technical Information Liquiline System CAT810 TI01138C/07/EN/02.16 71341422 Products Solutions Services Technical Information Control of sample preparation by the Liquiline System CA80 or a time control system Automatic sample preparation system for

More information

Modular Instrumentation System

Modular Instrumentation System www.swagelok.com Modular nstrumentation System Kenmac Series Modular 85 System Provides a standard modular instrumentation interface and mounting system: 2- and 4- valve pressure and differential pressure

More information

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31 LACT MEASUREMENT Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 79703 The Operation of L.A.C.T. Units The simplest approach to the understanding of the

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

MAP Sensor. Technical Spec COPY RIGHTS ECOTRONS ALL RIGHTS RESERVED ECOTRONS LLC. -Manifold Absolute Pressure Sensor

MAP Sensor. Technical Spec COPY RIGHTS ECOTRONS ALL RIGHTS RESERVED ECOTRONS LLC. -Manifold Absolute Pressure Sensor MAP Sensor -Manifold Absolute Pressure Sensor Technical Spec ECOTRONS LLC COPY RIGHTS ECOTRONS ALL RIGHTS RESERVED Note: If you are not sure about any specific details, please contact us at info@ecotrons.com.

More information

ROLLER GATES. Waterman Industries of Egypt. Roller gates are nominated for heavy duty service where large loads and sizes are going to be encountered.

ROLLER GATES. Waterman Industries of Egypt. Roller gates are nominated for heavy duty service where large loads and sizes are going to be encountered. ROLLER GATES Roller Gates are ideally suited for controlling water in any large openings such as may be found in power plants, water and sewage treatment facilities, flood control projects, irrigation

More information

31-SDMS-02 REV. 01 SPECIFICATIONS FOR

31-SDMS-02 REV. 01 SPECIFICATIONS FOR 31-SDMS-02 REV. 01 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PILLAR This specification is property of SEC and subject to change or modification without any notice C O N T E N T S S. NO. D E S C R I P

More information

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS 5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS 1.0 SCOPE 1.1

More information

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

Transformer Components & Accessories

Transformer Components & Accessories Transformer Components & Accessories Brian Brinson Mechanical Design Manager brian.brinson@spx.com Agenda 1. Standards / Equipment Overview 2. Bushings 3. Arresters 4. Cooling Equipment 5. Instrument Transformers

More information

Copeland Screw TM Compressors

Copeland Screw TM Compressors Copeland Screw TM Compressors Mechanical Guidelines for SHL & SHM Models using ESC-201 Control System Contents: Start-Up Procedure Operating Specifications Maintenance Trouble Shooting Guidelines Start-up

More information

Purging Air From Divider Block Lubrication Systems

Purging Air From Divider Block Lubrication Systems FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all

More information

AIR COOLED CHILLERS WATER COOLED CHILLERS

AIR COOLED CHILLERS WATER COOLED CHILLERS AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with

More information

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS INTRODUCTION The two most common methods of measuring the volume of petroleum liquids are tank gauging and liquid metering. The problems associated with

More information

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD. I EQUIPMENT : GAS/OIL FIRED INDIRECTLY HEATED ROTARY REACTOR. Technical Data : 01. Type : Indirectly heated. 02. Purpose : Heating / Drying / Calcination etc. 03. Feed Size : 0 25mm. 04. Feeder System

More information

DS Series Solar System

DS Series Solar System DS Series Solar System Permit information Consol 30-58-1800 Collector Flat mount on Colorsteel Plumdeck roofing Valve vent, Open loop http:// www.consolsolar.co.nz 21 Page 1 of This system is an evacuated

More information

ANSI Z50.1. Safety Standards

ANSI Z50.1. Safety Standards ANSI Z50.1. Safety Standards 5. Dry Ingredient Handling Equipment 5.1 General Requirements 5.1.1 Whenever a dry ingredient handling system is of such size that the beginning of its operation is remote

More information

Series 774 Automatic Skid Package

Series 774 Automatic Skid Package Fluid Engineering 1432 Walnut St Erie, PA 16502 USA PH 814.453.5014 FAX 814.452.6573 www.fluideng.com sales @fluideng.com CONTINUOUS FLOW The Fluid Engineering 774 Strainer Package is designed to handle

More information

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Rosemount 485 Annubar Threaded Flo-Tap Assembly Quick Installation Guide 00825-0500-809, Rev DB Threaded Flo-Tap 85 Annubar Rosemount 85 Annubar Threaded Flo-Tap Assembly Step 1: Location and Orientation Step 2: Weld Mounting Hardware Step 3: Install

More information

(770) Turning Parts Changers Into TROUBLESHOOTERS!

(770) Turning Parts Changers Into TROUBLESHOOTERS! Hydraulic Consulting, Inc. Turning Parts Changers Into TROUBLESHOOTERS! This e-book manual is your customized troubleshooting manual in Adobe Acrobat Portable Document File (PDF) format. It requires the

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

ENGINEERING STANDARD FOR MACHINERY PIPING

ENGINEERING STANDARD FOR MACHINERY PIPING ENGINEERING STANDARD FOR MACHINERY PIPING CONTENTS : PAGE No. 0. INTRODUCTION... 2 1. SCOPE... 3 2. REFERENCES... 3 3. UNITS... 4 4. PIPING DESIGN FOR MACHINERIES... 4 4.1 General... 4 4.2 Pumps... 5 4.3

More information

STANDBY EMERGENCY CNG/LPG GENERATOR

STANDBY EMERGENCY CNG/LPG GENERATOR SECTION 16620 STANDBY EMERGENCY CNG/LPG GENERATOR PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Compressed natural gas (CNG) or liquefied petroleum gas (LPG) powered standby emergency generators. B.

More information

MSC Guidelines for Fuel Oil Systems

MSC Guidelines for Fuel Oil Systems P. W. Gooding, CDR, Chief, Engineering Division References: Contact Information: a. 46 CFR 56.50-60 Systems containing oil (Subchapter F) b. 46 CFR 56.50-65 Burner fuel-oil service systems (Subchapter

More information

22 Kg/Sq.cm gauge at 55deg C. As per Design Code requirement. 100% requiredfor entire vessel

22 Kg/Sq.cm gauge at 55deg C. As per Design Code requirement. 100% requiredfor entire vessel LPG PRESSURE VESSEL FOR AUTO LPG PURPOSE S.NO. DESCRIPTION 1 Service Propane PARTIES CONFIRMATION 2 Type Underground 3 Design Code ASME - Sec VIII- Div II 4 Capacity (Water) KL 7.5 KL / 10 KL 5 Working

More information

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features Description BECSys CO 2 Feed Systems provide a rugged and reliable solution to ph control in aquatics facilities. CO 2 is recognized as a safe and easy-to-use method for ph control. BECSys CO 2 Feeder

More information

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL AUTOMATIC FILTERS, INC. 67 S. LA CIENEGA BLVD. LOS ANGELES, CA 90034 30 839 88 800 336 94 FAX 30 839 6878 www.tekleen.com info@tekleen.com Tekleen GB6 & GB7 USERS MANUAL GB6 & GB7 USERS MANUAL AUTOMATIC

More information

Rosemount 585 Annubar Flanged Flo-Tap Assembly

Rosemount 585 Annubar Flanged Flo-Tap Assembly Quick Installation Guide 00825-0200-585, Rev AA Flanged Flo-Tap 585 Annubar Rosemount 585 Annubar Flanged Flo-Tap Assembly Start Step 1: Location and Orientation Step 2: Weld Mounting Hardware Step 3:

More information

Technical Information for PVX Series Pumps

Technical Information for PVX Series Pumps Technical Information for PVX Series Pumps TM 604 PROGRESS DRIVE, HARTLAND, WI 53029 USA Phone: (262) 367-4299 FAX: (262) 367-5645 URL: www.hartmanncontrols.com E-mail: sales@hartmanncontrols.com PVX pumps

More information

Features 1. Differential Latch-type, lightweight, dependable

Features 1. Differential Latch-type, lightweight, dependable Bulletin 516 Rev. B Model DDX-SS Deluge Valve (100mm), (150mm) & (200mm) Bulletin 516 Rev. B Features 1. Differential Latch-type, lightweight, dependable construction. 2. Easily trimmed for releasing by:

More information

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS INTER PLANT STANDARD STEEL INDUSTRY SOFT STARTER FOR VOLTAGE UP TO 690 V AC IPSS: 1-10-040-15 IPSS NO CORRESPONDING IS 0. FOREWORD 0.1 This interplant standard has been prepared by the Standard Committee

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 22 1123.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

UD SERIES COMPRESSORS

UD SERIES COMPRESSORS UD SERIES COMPRESSORS INDUSTRIAL AIR COMPRESSOR 40-400 HP UPDRAFT MODELS Electric Motor - 460/575/3/60 standard (208/230/3/60 optional on most models) Motor Starter - 460 volt, full voltage magnetic starter

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP Installation, Operation, & Maintenance Manual Welker Sampler Model GSS-4HP The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

GENERAL-SERVICE COMPRESSED-AIR PIPING SECTION GENERAL-SERVICE COMPRESSED-AIR PIPING PART 1 - GENERAL

GENERAL-SERVICE COMPRESSED-AIR PIPING SECTION GENERAL-SERVICE COMPRESSED-AIR PIPING PART 1 - GENERAL 13686.00 GENERAL-SERVICE COMPRESSED-AIR PIPING 221513-1 SECTION 22 1513 - GENERAL-SERVICE COMPRESSED-AIR PIPING 1.1 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of the Contract,

More information

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

NIT No.:-10/WEX/MCR/HYD. PRESS/2-303/ /Dt

NIT No.:-10/WEX/MCR/HYD. PRESS/2-303/ /Dt Annexure-1 NIT No.:-/WEX/MCR/HYD. PRESS/2-303/21-12/Dt.02.03.22 Name of work:-retrofitting of new hydraulic power pack on 63 Ton Hydraulic Press, Plan No.1/2-303 SCOPE OF SUPPLY AND WORK: 1.0 Purpose of

More information

SOLAR HEATING SYSTEM

SOLAR HEATING SYSTEM SECTION 13600 SOLAR HEATING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07600 - Flashing and Sheet Metal. 2. 07900 - Joint Sealers. 3. 15260 - Thermal Insulation (Plumbing). 4. 15410 - Piping

More information

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS 5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS 1.0 SCOPE 1.1 Provide

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

Technical Specification Number S121 for Insulating Oil Purification Plant, Type E rev Q CONTENTS

Technical Specification Number S121 for Insulating Oil Purification Plant, Type E rev Q CONTENTS CONTENTS 1. GENERAL 2. SCOPE OF SUPPLY 3. DUTY AND PERFORMANCE 4. PROCESS DESCRIPTION 5. MAIN COMPONENTS 6. INSTRUMENTATION 7. ALARMS AND INTERLOCKS 8. OPTIONAL EQUIPMENT AND ACCESSORIES 9. COMMISSIONING

More information

Type 2000 Transducer Product Instructions

Type 2000 Transducer Product Instructions Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481038 Model PVF and PVG Indirect Gas-Fired Heat Modules Indirect Gas-Fired Furnaces Installation, Operation and Maintenance Manual Please read and save these instructions for future reference.

More information

MODEL NUMBER NOMENCLATURE. The model described above is a Side Access Housing, 4,000 CFM, 2 stages PX1224 cells, epoxy coated construction.

MODEL NUMBER NOMENCLATURE. The model described above is a Side Access Housing, 4,000 CFM, 2 stages PX1224 cells, epoxy coated construction. MODEL NUMBER NOMENCLATURE SAH12 4000 2 EC XXX OPTIONS: (SEE LIST BELOW) CONSTRUCTION: EC - Epoxy Coated SS - Stainless Steel G - Galvanized STAGES: 1, 2 or 3 CFM MODEL: SAH Side Access Housing 12 = PX

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION) INTER PLANT STANDARD STEEL INDUSTRY I P S S SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION) Corresponding IS does not exist IPSS: 1-10-036-12 0 FOREWORD 0.1 This

More information

Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: NEOTHERM Hydronic Boiler NTH Hydronic Boiler Indoor Sizes 285-850 Date: Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment High condensing

More information

Wet pipe low flow foam/water manifold system

Wet pipe low flow foam/water manifold system December 6, 2010 Foam 15a 1. Description With the Wet Pipe Low Flow Foam/Water Manifold System, multiple risers can be supplied from a single proportioning device. A riser manifold is installed with various

More information

Pneumatic High-Viscosity Filtration System Instruction Manual

Pneumatic High-Viscosity Filtration System Instruction Manual Pneumatic High-Viscosity Filtration System Instruction Manual P/N: 61512 05/17 1 2 Pneumatic High Viscosity Filtration Systems PN: 61512 14 April, 2009 rev A 36933 Pneumatic Hand Cart HV Filtration System

More information

G72x Series Direct Spark Ignition Controls

G72x Series Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition

More information

Section 9: Centralized Lubrication Systems

Section 9: Centralized Lubrication Systems ALEMITE LUBRICATION EQUIPMENT AND FLUID HANDLING PRODUCTS Oil Mist Systems Introduction Alemite Oil Mist Systems are used to service all types of machine elements that require continuous lubrication, such

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

SAMPLE SPECIFICATIONS

SAMPLE SPECIFICATIONS SAMPLE SPECIFICATIONS CONTENTS PART 1 GENERAL...H1a-12 1.1 DEAERATOR SPECIFICATION...H1a-12 PART 2 PRODUCTS...H1a-12 2.1 HARDWARE...H1a-12 A. Deaerator...H1a-12 B. Make Up Valve and Controller...H1a-14

More information

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL 13686.00 GENERAL SERVICE AIR COMPRESSOR 221519-1 SECTION 22 1519 - GENERAL-SERVICE AIR COMPRESSOR 1.1 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of the Contract, including General

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Manual Polymer Makedown Systems Manufacturers of Quality Pumps, Controls, and Systems Standard Product Operations 27101 Airport Rd., Punta Gorda, FL 33982

More information

HTX-HTH SEPARATORS I&O MANUAL

HTX-HTH SEPARATORS I&O MANUAL INSTALLATION OPERATIONS AND MAINTENANCE HTX-HTH SEPARATORS I&O MANUAL 1365 N. Clovis Avenue Fresno, California 93727 (559) 255-1601 www.lakos.com LS-714B (Rev. 11/17) TABLE OF CONTENTS Table of Contents...

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

Section 3 Technical Information

Section 3 Technical Information Section 3 Technical Information In this Module: Engine identification Modes of operation Battery charging and heat manage operation Service and repair procedures Maintenance requirements Engine Identification

More information

ROOTS Meters Series B3 Meter Models 8C175-56M175

ROOTS Meters Series B3 Meter Models 8C175-56M175 ROOTS Meters Series B3 Meter Models 8C175-56M175 Refer to IOM-B3 for Complete Instructions IS:B3 3.03 RECEIVING, HANDLING AND STORAGE ROOTS rotary positive displacement gas meters are precision measurement

More information

Publication No.: PSG

Publication No.: PSG TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06

More information

Applications. Compressor-Features The Vilter Advantages. LNG Boil Off Gas Gathering BIO - Gas Digester CO 2 Nitrogen Hydrogen Refrigerant

Applications. Compressor-Features The Vilter Advantages. LNG Boil Off Gas Gathering BIO - Gas Digester CO 2 Nitrogen Hydrogen Refrigerant Parallex TM Slide System - It s the key to part load efficiencies far superior to twin screw compressors. Capacity and volume slides move independently of each other based on load, eliminating over or

More information

SPECIFICATION OF TRAILOR MOUNTED SEWER JETTING MACHINE RAMJET 1500 Lts.

SPECIFICATION OF TRAILOR MOUNTED SEWER JETTING MACHINE RAMJET 1500 Lts. Specification of Trailer Mounted Sewer Jetting Machine (Ramjet 1500 Lts.) Page 1 of 5 GENERAL :- SPECIFICATION OF TRAILOR MOUNTED SEWER JETTING MACHINE RAMJET 1500 Lts. The trailor mounted Sewer Jetting

More information

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

Integrated Flow Control Module for Slurries and Chemicals LFC-7000 Integrated Flow Control Module for Slurries and Chemicals LFC-7000 Operating Instructions and Quick-Start Guide TABLE OF CONTENTS Introduction 3 Storage and Handling 3 Installation Instructions 4 Operating

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481038 Model PVF(-H) and PVG Indirect Gas-Fired Heat Modules Indirect Gas-Fired Furnaces Installation, Operation and Maintenance Manual Please read and save these instructions for future reference.

More information

Installation Instructions

Installation Instructions AQU244 & AQU128 Series Installation Instructions Installation Instructions AQU244 24vdc 5A Supervised Power Supply/Charger module AQU128 12vdc 10A Supervised Power Supply/Charger module Both Mounted in

More information

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE SRC STEAM RESET CONTROL An Outdoor Reset Control for Sub-Atmosphere Steam Systems Heat-Timer s theory of steam reset heating is as follows: Pulse the valve open to a limited valve position, very slowly

More information

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA 017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS PAGE 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable Standards 3 5. Basic Features 4 6. Quality

More information

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE REPAIR PARTS AND SPECIAL TOOLS LIST FOR

TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE REPAIR PARTS AND SPECIAL TOOLS LIST FOR *TM 5-3820-256-24P-3 TECHNICAL MANUAL UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE REPAIR PARTS AND SPECIAL TOOLS LIST FOR DRILLING SYSTEM, WELL, ROTARY, TRUCK MOUNTED, AIR TRANSPORTABLE, 600-FOOT

More information

SECTION H3 TRAYMASTER SERIES DEAERATORS

SECTION H3 TRAYMASTER SERIES DEAERATORS SECTION H3 TRAYMASTER SERIES DEAERATORS SAMPLE SPECIFICATIONS PART 1 GENERAL... H3-12 1.1 Packaged Deaerator Specification... H3-12 PART 2 PRODUCTS... H3-12 2.1 Deaerator... H3-12 2.2 Deaerator Vessel...

More information

HKV 1 1/4 in. Brass Manifold Product instructions. Construction Automotive Industry

HKV 1 1/4 in. Brass Manifold Product instructions.   Construction Automotive Industry HKV 1 1/4 in. Brass Manifold Product instructions www.rehau.com Construction Automotive Industry SCOPE This guide provides instruction regarding HKV 1 1/4 in. manifold installation and operation. Manifolds

More information

VTZ variable speed Reciprocating compressors

VTZ variable speed Reciprocating compressors MAKING MODERN LIVING POSSIBLE Application guidelines VTZ variable speed Reciprocating compressors R404A, R507, R407C, R134a www.danfoss.com CONTENT VARIABLE SPEED COMPRESSORS... 4 Speed control...4 Advantages

More information

TotalPac 3 Firecyle III Wet pipe Remote controlled system

TotalPac 3 Firecyle III Wet pipe Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical

More information

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) PACKAGED PUMP SYSTEM WITH CAPACITIES TO 300GPM, PRESSURE BOOST TO 100PSI* WITH UP TO 25HP ON EACH PUMP AVAILABLE IN DUPLEX, AND TRIPLEX CONFIGURATION, AND

More information

TotalPac 3 Deluge, Electric release Remote controlled system

TotalPac 3 Deluge, Electric release Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a deluge system trim totally preassembled, pre-wired and factory tested. All electrical and

More information

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) 1 SCOPE OF SUPPLY This specification covers design, manufacture, shop

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Installation and Maintenance Manual Automated Fuel Maintenance System FTI-2.8 FUEL TECHNOLOGIES INTERNATIONAL 01/01/2014 Rev A - Fuel Technologies - FTI-2.8 with ModBus OPERATIONS & MAINTENANCE CONTENTS

More information

ITS-50R TRANSFER SWITCH OWNER S MANUAL

ITS-50R TRANSFER SWITCH OWNER S MANUAL ITS-50R OWNER S MANUAL IOTA Engineering Transfer Switches provide automatic power switching between two or three separate 120/240 volt AC input sources, including powercords, onboard generators, onboard

More information

Float Valve MODEL. Schematic Diagram. Optional Features. Typical Applications. Installation. Product Dimensions Data:

Float Valve MODEL. Schematic Diagram. Optional Features. Typical Applications. Installation. Product Dimensions Data: 2 CF1-C1 Float Control 124-01 (izes 1/2"- 6" Full Internal ort) 624-01 (izes 3"- 8" Reduced Internal ort) Float Valve On-Off or Non-Modulating ction Fully djustable High and Low Level ettings imple Design,

More information