Section 11. Obsolescent and Obsolete Circuit Breakers. Table of Contents. Obsolescent and Obsolete Types. Obsolescent Circuit Breakers

Size: px
Start display at page:

Download "Section 11. Obsolescent and Obsolete Circuit Breakers. Table of Contents. Obsolescent and Obsolete Types. Obsolescent Circuit Breakers"

Transcription

1 Table of Contents Section Obsolescent and Obsolete Circuit Obsolescent and Obsolete Types Circuit Breaker Availability -2 Pictorial and Dimensions -4-5 Obsolescent Circuit F-Frame Thermal-Magnetic Circuit -6 K-Frame Thermal-Magnetic Circuit -7 Automatic Molded-Case Switches -8 Mag-Gard Motor Circuit Protector UL Listed Marine Circuit - Circuit for NQO, NQOB and NQOD Panelboards, Branch -12 Circuit and Mounting Assemblies for ML Panelboards Plugs For Obsolete lectronic Trip Circuit -13 H/HB Circuit -14 FJA Thermal-Magnetic Circuit -15 Q Metering Circuit -16 KD/KG Thermal-Magnetic Circuit -17 NHL Thermal-Magnetic Molded Case Circuit Breaker -18 S Circuit Breaker with Full-Function Trip Unit -19 S Circuit Breaker Accessories -20 M-frame Thermal-Magnetic Circuit -21 Field-Installable Accessories -22 Mechanical Lug Information -23 Micrologic Series 2/3/A/B Trip Unit Test Sets -24 Micrologic Add-On Ground-Fault Module (GFM) -25 Masterpact M/MP/MC Circuit, UL 489/1066 Listed -26 Masterpact M/MP/MC Circuit Breaker Control Units -27 Masterpact M/MP/MC Circuit Breaker Accessories Masterpact M/MP/MC Circuit Breaker Spare Parts Schneider lectric -1 This document provided by Barr-Thorp lectric Co., Inc

2 Obsolescent and Obsolete Types Table.1: Circuit Breaker Availability Contact your local Sales Office for availability. Circuit Breaker Availability Class Series of Availability Frame Size Volts Poles s Obsolete No Longer Available Obsolescent 5A 130A MO-1 (Add-on) 120 Vac X 215A 250A MO-2 (Add-on) 120/240 Vac X 215B 250B MO-2B (Add-on) 120/240 Vac 2 S.P X Multi-Breaker 120 Vac 4 S.P X 1600 MO-2 120/240 Vac X MO-2 120/240 Vac X 1501 MO Vac X MO-2 120/240 Vac X 1601 MO Vac 1 With SN X MO-2 120/240 Vac 2 With SN X MO-2 120/240 Vac 2 S.P X MB (Left-hand) 120 Vac 4 S.P X MB (Right-hand) 120 Vac 4 S.P X MO-8 120/240 Vac 4 S.P X MO-4 120/240 Vac 4 S.P X MO-4 (Plug-in) 120/240 Vac 4 S.P X LM 600 Vac X A Form W 250 Vac 1, 2, X A Form W 250 Vac 2, X A Form W 250 Vac 2, X Flip-on Form W 230 Vac 1, 2, X A Form W (Trip Unit) 250 Vac 2, X A Form W 250 Vac 2, X A Form W 250 Vac 2, X A (KL) Form W 250 Vac 2, X A (WL) Form W 250 Vac 2, X KL Frame Only 600 Vac 2, X A Form W 600 Vac 2, X A Form W 600 Vac 2, X A Form W 600 Vac 2, X A Form W 600 Vac 2, X A Form W 600 Vac 2, X A (KL) Form W 600 Vac 2, X A (WL) Form W 600 Vac 2, X Type L Form W 240 Vac 1, 2, X Type L Form W (Flip-on) 240 Vac 1, 2, X M1 (Bolt-on) 240 Vac 2, X M2 (Bolt-on) 240 Vac 2, X MM (M) (Bolt-on) 120/240 Vac 2 S.P X A Trip Unit 250 Vac 2, X A Trip Unit 250 Vac 2, X KL Trip Unit 600 Vac 2, X LM Trip Unit 600 Vac 2, X WL Frame 600 Vac 2, X A Form W (Flip-on) 125/250 Vac 1, 2, X ML Vac 2, X A (G) Form W 600 Vac 2, X A (F) Form W 600 Vac 2, X ML Vac 2, X ML Vac 2, X ML Vac 2, X QB 120/240 Vac X ML 120/240 Vac 1, 2, X ML Form Y 277 Vac X ML Vac 2, X A (G) Form W 600 Vac 2, X A (F) Form W 600 Vac 2, X ML Vac 2, X ML Vac 2, X ML Vac 2, X A1B 100 A 120/240 Vac 1, 2, X H, HB 100 A 480Y/277 Vac 1, 2, H See page -14 FC 100 A 480 Vac 2, FC See page -5 FD, FG, FJ 100 A 480Y/277 Vac 1, 2, X GJL / NNL 100 A 480 Vac X KA, KH, KC 250 A 480 Vac 2, X See pgs Schneider lectric This document provided by Barr-Thorp lectric Co., Inc

3 Table.2: Obsolescent and Obsolete Types Circuit Breaker Availability. Continued Contact your local Sales Office for availability. Circuit Breaker Availability Class 600 Series of Availability Frame Size Volts Poles s Obsolete No Longer Available Obsolescent FI, FIL 100 A 480 Vac 2, X KI, KIL 225 A 480 Vac 2, X LI, LIL 400 A 480 Vac 2, X KD, KG 250 A 240 Vac 2, KG See page -17 LA(JKL) A 600 Vac 2, X MA A 600 Vac 2, X Masterpact M/MP/MC 6300 A 600 Vac 3, See pgs MC 225 A 600 Vac 2, X MC 400 A 600 Vac 2, X MC 800 A 600 Vac 2, X MHAB, BC, CA MM (Plug-on) 120/240 Vac 2 S.P X MHAB, BC, CA M1 (Plug-on) 120/240 Vac 2, X MHAB, BC, CA M2 (Plug-on) 120/240 Vac 2, X NHL 1200 A 480 Vac 2, See page -18 PC 1200 A 600 Vac 2, X PC 1600 A 600 Vac 2, X PC 2000 A 600 Vac 2, X QOT Series 1 120/240 Vac 1, 2 30 X Q1, Q1B 150 A 120/240 Vac 1, X Q1, Q1B 150 A 240 Vac X Q1-H, Q1B-H 100 A 240 Vac X Q1-VH, Q1B-VH 125 A 120/240 Vac X Q1-VH, Q1B-VH 100 A 240 Vac X Q2, Q2-H, Q2H 225 A 240 Vac 2, X Q 200 A 120/240 Vac 2, See page -16 S 4000 A 600 Vac See pgs. -20 CK 1200 A 480 Vac X CM 2000 A 480 Vac X XO 50 A 120/240 Vac 1, X Y1B 100 A 277 Vac X M, ML 250 A, 400 A, 800 A 600 Vac X MX, MXL 250 A, 400 A, 800 A 600 Vac X NA, NAL 1200 A 600 Vac X NC, NCL 1200 A 600 Vac X NX, NXL 1200 A 600 Vac X N, NL 1200 A 600 Vac X PAF 2000 A 600 Vac X PHF 2000 A 600 Vac 2, X PCF 2500 A 600 Vac 2, X PXF 2500 A 600 Vac 2, X PF 2500 A 600 Vac X 2012 Schneider lectric This document provided by Barr-Thorp lectric Co., Inc

4 Obsolescent and Obsolete Types Pictorial and Dimensions Class LIL LA (W) MA (W) ML-2 ML-1 Table.3: Circuit Breaker Dimensions Dimensions Circuit Breaker Number A B C D F G H Type Prefix Poles in. mm in. mm in. mm in. mm in. mm in. m m in. mm in. mm QB ML ML & ML & ML & LA (W) LA 2 & MA (W) MA 2 & KL & LM & FIL (4) IFL 2 & KIL (4) IKL 2 & LIL ILL 2 & NHL NHL 2 & H B G H D C A F Schneider lectric This document provided by Barr-Thorp lectric Co., Inc

5 Obsolescent and Obsolete Types Pictorial and Dimensions Class 600 Figure 1 A A Figure 3 A H, HB D C Figure 4 B G HH D C B B B A F C/L A F C/L B Figure 6 B G HH D C B G D C B A F C/L A F A C D A B G F A F B C/L A F D C B G HH C/L D C Table.4: Circuit Breaker Dimensions Circuit Breaker No. Fig. Dimensions In. Prefix Poles No. A B C D F G H H, HB a a Width 1.50 FDA, FGA, FJA 2, 3 Width 3.00 Q2L, Q2L-H KD, KG 2, MXL, ML 2 & NAL, NCL, NL, NXL 2 & FCL c MAL, MHL 2 & NA, NC, NX, N 2 & PA, PH, PX, P 2 & PC, PX-25, P & a A is 4.00 in. b Dimensions are 1.59 in at ON end and 0.63 in at OFF end. c FCL 2-pole circuit breaker dimension B is 4.50 as in Fig b b Table.5: Frame Size MAL MHL PAF PHF PXF PF Approx. Shipping Weight (Lbs.) B G F D C A 2012 Schneider lectric This document provided by Barr-Thorp lectric Co., Inc

6 Obsolescent Circuit F-Frame Thermal-Magnetic Circuit Class FC circuit breakers are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. FAL/FHL 2P A Thermal-magnetic molded case circuit breakers shown on page -6 are permanent trip UL Listed, CSA Certified, IC rated, and also meet the requirements of Federal Specification W C 375B/GN as indicated on Digest pages 7-4 through 7-7. NOT: Consider using PowerPact circuit breakers for situations requiring circuit breaker accessories. See Digest Section 7 for more information. FAL/FHL 3P A Table.6: F-Frame 100 A, Thermal-Magnetic, Individually-Mounted, 480 Vac xtra-high Interrupting Fixed AC Magnetic 2P 3P Terminal Trip 480 Vac, 250 Vdc 480 Vac, 250 Vdc Wire Range (AWG) Hold Trip 15 A 275 A 600 A FCL A 275 A 600 A FCL A 275 A 600 A FCL A 275 A 600 A FCL A 400 A 850 A FCL A 400 A 850 A FCL A 400 A 850 A FCL A 400 A 850 A FCL24050 FCL A 800 A 1450 A FCL24060 FCL A 800 A 1450 A FCL24070 FCL A 800 A 1450 A FCL24080 FCL A 900 A 1700 A FCL24090 FCL A 900 A 1700 A FCL24100 FCL34100 CU30FA4 (1) Cu AL100FA4 (1) 14 3 Cu or (2) 12 1 Al Table.7: Interrupting s FAL Voltage FHL FCL FIL 240 Vac 480 Vac 600 Vac 240 Vac 10 ka 18 ka (1P), 25 ka (2P, 3P) 25 ka 25 ka (1P) 65 ka (2P, 3P) 100 ka 200 ka 480 Vac 18 ka 18 ka 25 ka (2P, 3P) 65 ka 200 ka 600 Vac 14 ka 18 ka (2P, 3P) 100 ka FA 2P 3 in. (76 mm) Mounting Height FA 3P 4.5 in. (4 mm) Mounting Height Termination Option Termination Letter F = No Lugs L = Lugs both ends P with MT Suffix = Lugs ON end P = Lugs OFF end Table.8: For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number. F A L Termination Letter F-Frame 100 A, Thermal-Magnetic, I-Line Construction, 480 Vac xtra-high Interruptingc Fixed AC Magnetic 2Pa 3P Trip Terminal 480 Vac, 250 Vdcb 480 Vac, 250 Vdcc Wire Range Hold Trip (AWG) 15 A 275 A 600 A FC A 275 A 600 A FC34020 CU30FA4 25 A 275 A 600 A FC34025 (1) Cu 30 A 275 A 600 A FC A 400 A 850 A FC A 400 A 850 A FC A 400 A 850 A FC A 400 A 850 A FC24050( ) FC34050 AL100FA4 60 A 800 A 1450 A FC24060( ) FC34060 (1) 14 3 Cu 70 A 800 A 1450 A FC24070( ) FC34070 or (1) 12 1 Al 80 A 800 A 1450 A FC24080( ) FC A 900 A 1700 A FC24090( ) FC A 900 A 1700 A FC24100( ) FC34100 a 1P and 2P circuit breaker catalog numbers are completed by adding the required phase connection letters as a suffix. See Phase Option Table. b FCL 2P circuit breakers are built using 3P module. c FCL circuit breakers are not rated for 250 Vdc. Table.9: Phase Options Table.10: Interrupting s Phase Option Letter A B C AB AC BC ABC CBA 1P 2P 3P Voltage FA FH FC FI 240 Vac 480 Vac 600 Vac FA14035A 240 Vac 10 ka 18 ka (1P), 25 ka (2P, 3P) 25 ka 25 ka (1P) 65 ka (2P, 3P) 100 ka 200 ka FA14035B 277 Vac 18 ka 65 ka FA14035C 480 Vac 18 ka 18 ka 25 ka (2P, 3P) 65 ka 200 ka FA24030AB 600 Vac 14 ka 18 ka (2P, 3P) 100 ka FA24030AC FA24030BC FA34030 FA34030CBA Accessories Page -28 OptionalLugs Page -23 Dimensions Page -5 nclosures: see Digest Section Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

7 Obsolescent Circuit K-Frame Thermal-Magnetic Circuit Class 655, 825, 660 K-frame circuit breakers are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. KA/KH/KC 2P and 3P 4.5 in. (4 mm) Mounting Height Table.: K-Frame 250 A, Thermal-Magnetic, Individually-Mounted, 600 Vac Adjustable AC Magnetic Tripa Standard High xtra-high Interrupting Interrupting Interruptingb Low High 2P, 600 Vac, 250 Vdc A 700 A KAL26070 KHL A 800 A KAL26080 KHL A 900 A KAL26090 KHL A 1000 A KAL26100 KHL A 00 A KAL260 KHL260 KCL A 1250 A KAL26125 KHL26125 KCL A 1500 A KAL26150 KHL26150 KCL A 1750 A KAL26175 KHL26175 KCL A 2000 A KAL26200 KHL26200 KCL A 2250 A KAL26225 KHL26225 KCL A 2500 A KAL26250 KHL26250 KCL P, 600 Vac, 250 Vdc A 700 A KAL36070 KHL A 800 A KAL36080 KHL A 900 A KAL36090 KHL A 1000 A KAL36100 KHL A 00 A KAL360 KHL360 KCL A 1250 A KAL36125 KHL36125 KCL A 1500 A KAL36150 KHL36150 KCL A 1750 A KAL36175 KHL36175 KCL A 2000 A KAL36200 KHL36200 KCL A 2250 A KAL36225 KHL36225 KCL A 2500 A KAL36250 KHL36250 KCL34250 Table.12: K-Frame 250A, Thermal-Magnetic, I-Line Construction, 600 Vac Terminal Wire Range AL250KA (1) 4 AWG 350 kcmil Al AL250KA (1) 4 AWG 350 kcmil Al Adjustable AC Magnetic Tripa Standard High xtra-high Interrupting Interrupting Interruptingb Terminal Low High Wire Range 2P, 600 Vac, 250 Vdcc A 700 A KA26070( ) KH26070( ) A 800 A KA26080( ) KH26080( ) A 900 A KA26090( ) KH26090( ) A 1000 A KA26100( ) KH26100( ) A 00 A KA260( ) KH260( ) KC240( ) AL250KA A 1250 A KA26125( ) KH26125( ) KC24125( ) (1) 4 AWG 350 kcmil Al A 1500 A KA26150( ) KH26150( ) KC24150( ) A 1750 A KA26175( ) KH26175( ) KC24175( ) A 2000 A KA26200( ) KH26200( ) KC24200( ) A 2250 A KA26225( ) KH26225( ) KC24225( ) A 2500 A KA26250( ) KH26250( ) KC24250( ) 3P, 600 Vac, 250 Vdc A 700 A KA36070 KH A 800 A KA36080 KH A 900 A KA36090 KH A 1000 A KA36100 KH A 00 A KA360 KH360 KC340 AL250KA A 1250 A KA36125 KH36125 KC34125 (1) 4 AWG 350 kcmil Al A 1500 A KA36150 KH36150 KH A 1750 A KA36175 KH36175 KC A 2000 A KA36200 KH36200 KC A 2250 A KA36225 KH36225 KC A 2500 A KA36250 KH36250 KC34250 a UL magnetic trip setting tolerances are ±25% for low and ±20% for high from nominal value shown. b KC circuit breakers are 480 Vac c 2P and 3P circuit breaker catalog numbers are completed by adding the required phase connection letters as a suffix. See Phase Option Table. Table.13: Interrupting s Table.14: Phase Options Voltage KA, KAL KH, KHL KC, KCL KI, KIL Phase Option Letter 2P 3P 240 Vac 42 ka 65 ka 100 ka 200 ka AB KA26250AB 480 Vac 25 ka 35 ka 65 ka 200 ka AC KA26250AC 600 Vac 22 ka 25 ka 100 ka BC KA26250BC Table.15: Walking Beam Mechanical Interlock Componentse ABC CBA KA36250 KA36250CBA Circuit Manually Operated lectrically Operated Breaker Operator Walking Beam Mounting Pan Cat. Operator Walking Beam Prefix Suffix Ass'y. No. Suffix Ass'y. Mounting Pan KAL WB KA4WB KAWBP4 WBMO KA9WB KAWBP9 d Walking Beam Mechanical Interlock requires 2 circuit breakers with WB suffix, 1 walking beam assembly and 1 mounting pan. e Fully enclosed interlocked units are available in Type 1 and Type 3R enclosures, with two neutrals provided in each enclosure. The completely enclosed assembly is not UL Listed. Consult your nearest Schneider lectric local sales office for more information. Accessories Page -28 OptionalLugs Page -23 Dimensions Page -5 nclosures: see Digest Section Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

8 Obsolescent Circuit Automatic Molded-Case Switches Class 680, These automatic molded case switches are in obsolescence. Do not use on new applications. Limited service stock is available for replacement or fill purposes. Contact your local Sales Office for product availability. Automatic Molded Case Switches Automatic molded case switches open instantaneously at a factory preset magnetic trip point, calibrated to protect only the molded case switch itself, when it is subjected to high fault currents. The trip point is nonadjustable and provides no overload or low level fault protection. Molded case switches open when the handle is switched to the OFF position or in response to an auxiliary tripping device such as a shunt trip. Automatic switches will accept the same lugs and accessories as equivalent thermal-magnetic circuit breakers. Automatic molded case switches are UL Listed per UL 489 and are CSA Certified. Table.16: Automatic Molded Case Switches, 600 Vac 2P 3P Withstand dc Trip Point (A)a Lug Kit Installed Availability Availability 240 Vac 480 Vac 600 Vac 250 Vdc AC DC 100 FHL26000Mb FHL36000Mb 65k 25k 18k 10k AL100FA 150 FHL Mb 65k 25k 18k 2500 AL150FA 400 LHL26000M LHL36000M 65k 35k 25k 10k AL400LA 250 KHL26000Mb KHL36000Mb 65k 35k 25k 10k AL250KA 600 MHL260006M MHL360006M 65k 65k 25k 10k AL900MA 800 MHL260008M MHL360008M 65k 65k 25k 10k AL900MA a UL magnetic trip tolerances are -20% / +30% from the nominal values shown. b FHL and KHL automatic switches will not accept cylinder lock attachments. c The withstand rating is the fault current at rated voltage that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. d The short circuit current rating is the fault current, at rated voltage, that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. Accessories Page -28 OptionalLugs Page -23 Dimensions Page Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

9 Obsolescent Circuit Mag-Gard Motor Circuit Protector Class 680, 685 These Mag-Gard motor circuit protectors are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. Mag-Gard Motor Circuit Protector Instantaneous trip magnetic only circuit breakers have a single adjustment which simultaneously sets the magnetic trip level of each individual pole. Mag-Gard circuit breakers comply with NC requirements for providing motor circuit protection when installed as part of a UL Listed combination controller having motor overload protection. Interrupting ratings are established for these UL Recognized Components only when they are used in combination with motor starters with properly sized overload relays and contactors. Mag-Gard circuit breakers will accept the same lugs and accessories as equivalent thermal-magnetic circuit breakers. Mag-Gard circuit breakers are available with I-Line construction. H-construction Mag-Gard circuit breakers are also available. Table.17: Magnetic Only A 600 Vac, 50/60 Hz KAL FAL a Adjustablea Trip Range 3P only 150 A A KAL M 250 A 3 A 7 A 15 A 30 A 30 A 50 A 100 A 100 A A A A A A 8 28 A A A A A A A KAL M KAL M KAL M KAL M KAL M FAL36003M FAL M FAL M FAL M FAL M FAL M FAL M FAL M UL magnetic trip setting tolerances are -20%/+30% from the nominal values shown. Adjustable instantaneous-trip circuit breakers are intended for use in combination with motor starters with overload relays for the protection of motor circuits from short circuits. Other specific applications include rectifiers and resistance welders. These circuit breakers contain a magnetic trip element in each pole with the trip point adjustable from the front. Interrupting ratings are determined by testing the instantaneous-trip circuit breakers in combination with a contactor and overload relay. Select instantaneous-trip circuit breakers as follows: 1. Use selection table for motors, other than NMA Design, with locked-rotor indicating code letters per NC Table (b) as follows: Horsepower Motor Code Letters 1/2 or less A L 3/4 to 1-1/2 A K 2 to 3 A J 5 to 25 A H 30 to 125 A G 150 or more A F For other motors order a special thermal-magnetic circuit breaker with magnetic trip settings for the specific motor specify motor horsepower, voltage, frequency, full-load current and code letter or locked rotor current. 2. Determine motor hp rating from the motor nameplate. 3. Refer to the table at right and select an instantaneous-trip circuit breaker with an rating recommended for the hp and voltage involved. 4. Select an adjustable trip setting of at least 800%, not to exceed 1300%, of the motor full-load s. (FLA) for other than Design motors. For Design motors, select an adjustable trip setting of at least 00% not to exceed 1700% of FLA. 5. The NC 1300% maximum setting may be inadequate for instantaneous-trip circuit breakers to withstand current surges typical of the magnetization current of autotransformer type reduced voltage starters, or open transition wye-delta starters during transfer from start to run, constant hp multi-speed motors, and motors labeled high efficiency. Select thermal-magnetic circuit breakers from Digest page 7-32 for those applications. 6. Part-winding motors, per NC 430.3, should have two circuit breakers selected from the above at not more than one half the allowable trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a disconnecting means per NC Accessories Page -28 OptionalLugs Page -23 Dimensions Page Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

10 Obsolescent Circuit a b Mag-Gard Motor Circuit Protector Class 680, 685 Table.18: Adjustable Instantaneous-Trip Circuit for Single Motor Circuit Protection Hp s of Induction Type Squirrel-Cage and Wound Rotor Motors 3Ø 60 Hz ac V 230 V 460 V 575 V MIN MAX 1/2 0.8 FAL36003Ma 1000% 3500% 1/2 1 FAL36003Ma 800% 2800% 3/4 1.1 FAL36003M 700% 2500% 3/ FAL36003M 600% 2000% FAL36003M 400% 1600% 1/2 2 FAL36003M 400% 1400% 1-1/2 2.1 FAL36003M 400% 1300% 1/2 2.3 FAL36003M 300% 1200% 1-1/2 2.6 FAL M 700% 2700% FAL M 700% 2600% 3/4 2.8 FAL M 600% 2500% 3/4 3.2 FAL M 600% 2200% FAL M 500% 2100% FAL M 500% 1900% FAL M 500% 1800% FAL M 400% 1700% FAL M 400% 1500% 1-1/2 5.2 FAL M 300% 1300% 1-1/2 6 FAL M 300% 1200% FAL M 300% 00% FAL M 700% 2600% FAL M 700% 2400% FAL M 600% 2300% 7-1/2 9 FAL M 600% 2000% FAL M 500% 1900% 3 7-1/2 10 FAL M 500% 1600% FAL M 700% 2500% FAL M 700% 2300% FAL M 600% 2100% FAL M 600% 2000% FAL M 500% 1700% 7-1/ FAL M 700% 2600% 7-1/ FAL M 600% 2300% FAL M 600% 2100% FAL M 500% 2100% FAL M 500% 1800% FAL M 500% 1800% FAL M 400% 1700% FAL M 400% 1500% FAL M 700% 2700% FAL M 700% 2600% FAL M 600% 2300% FAL M 600% 2100% FAL M 600% 2000% FAL M 500% 1800% FAL M 500% 1700% FAL M 400% 1600% KAL M 700% 1400% KAL M 700% 1400% KAL M 700% 1400% KAL M 700% 1300% KAL M 700% 1500% KAL M 700% 1400% KAL M 700% 1400% KAL M 700% 1400% KAL M 700% 1300% Motor full-load currents are taken from NC Table Select wire and circuit breakers on basis of horsepower rather than nameplate full-load current per NC (A) for general motor applications. Do not use these values to select overload relay thermal units. See Digest Section 15 for selection of thermal units when actual full load current is not known. The voltages listed are rated motor voltages. Corresponding nominal system voltages are 200 to 208, 220 to 240, 440 to 480 and 550 to 600 volts. Only MIN and MAX settings are shown, intermediate settings are available on all circuit breakers. Accessories Page -28 OptionalLugs Page -23 Dimensions Page -5 Full Load sa Mag-Gard Circuit Breaker Magnetic Trip Settings b Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

11 Obsolescent Circuit UL Listed Marine Circuit Class 600 These marine circuit breakers are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. A standard for molded case circuit breakers which are intended to be installed and used aboard a boat or vessel is included in Supplement SA to UL 489, Standard for Molded Case Circuit and Circuit Breaker nclosures (also referred to as UL product category DKTY). This UL Standard was established in accordance with U.S. Coast Guard regulations, applicable American Boat and Yacht Council Inc. publications, and NFPA 302 Standard for Motor Craft (Pleasure and Commercial). In order to be UL Listed for marine use, circuit breakers must not use aluminum or aluminum alloys for terminal connections and must be calibrated at an ambient temperature of 40 o C. Standard circuit breakers should not be specified or used in place of marine circuit breakers. The following table lists those circuit breakers which are UL Marine Listed for use on vessels over 65 ft. (19.8 m) in length. (PowerPact H and J-frame circuit breakers can also be used in vessels under 65 ft. [19.8 m] in length.) Table.19: CIrcuit for Marine Applications Prefix Poles FC, FCL 2, A KA, KAL 2, A KH, KHL 2, A KC, KCL 2, A Application $ Price For use only on vessels over 65 feet (19.8 m) in length. Add the number 9 after the catalog number prefix of the standard circuit breaker catalog number. xample: Standard FAL36100 Marine FAL There is a 20% adder to the price of the equivalent standard circuit breaker. All marine circuit breakers are supplied with copper lugs Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

12 Obsolescent Circuit Circuit for NQO, NQOB and NQOD Panelboards, Branch Circuit and Mounting Assemblies for ML Panelboards NQO, NQOB, and NQOD circuit breakers and panelboards are obsolete. Do not use on new applications. Limited service stock is available for replacement or fill purposes. Contact your local Sales Office for product availability. 2P QO 2P QOB 2P Q1 Replacing Obsolescent Q1 and Q1B Circuit In NQO, NQOB and NQOD Panelboards Q1 and Q1B circuit breakers have been replaced by QO and QOB circuit breakers. Table 1 below is used for replacing 1P, 2P or 3P Q1 and Q1B circuit breakers with QO and QOB branch circuit breakers in NQO, NQOB and NQOD panelboards. Table 2 below is used for replacing Q1 and Q1B main circuit breakers in NQO and NQOB panelboards. Table.20: Replacing Q1 and Q1B Circuit with QO and QOB Branch Circuit a b c Panelboard Branch Circuit Breaker Mounting Assembly Type Obsolete Available Requiredc NQOB Q1B QOB SK5668 NQOD QO SKNQOD225b NQOD QOB SKNQOD225b Table.21: Replacing Q1 and Q1B Main Circuit in NQO and NQOB Panelboards Panelboard Main Circuit Breaker Mounting Assembly Retaining Kit Type Obsolete Available Requiredc Required NQOB Q1B QOB SK5668 Mounting assembly SK5669 is used to mount both Q1 and QO circuit breakers. Not required for replacement purposes. 225 A maximum. For ampere circuit breaker mounting assembly, see Class 1630 Service Bulletin. Discount P1A. Branch Circuit and Mounting Assemblies for ML Panelboards Replacement circuit breakers for ML panelboards are determined by the manufacture date of the panel and the panel depth. (See chart below) Table.22: Replacement Circuit in ML Panelboards Panel Depth Manufacture Date Availability of Replacement Circuit in. mm No Replacements Available No Replacements Available Refer to Tables Below The tables below are used for replacing or adding circuit breakers to 10-5/8 inch deep ML panelboards manufactured from and for switchboards manufactured from Table.23: Replacement of xisting Circuit xisting Circuit Mounting Height Replacement Mounting Breaker Prefix Circuit Assembly Poles Single or Twin Breaker Required Required (Mounting in. mm Assembly) Availability ML A or 999 FAL SK4515d 3P Twin ML A KAL SK4516d 3P Twin LA (W) LA LAL SK4517 3P Single MA (W) A MA MAL SK4578 3P Single FAL A FAL FAL 3P Twin No KAL A KAL KAL Mounting 3P Twin LAL A LAL LAL Assembly 3P Single Required MAL A MAL MAL 3P Single MAL A MAL LAL SK4517 3P Single Table.24: Adding New Circuit d Mounting Assembly Mounting Height Prefix Required in. mm Poles Required Single or Twin (Mounting Assembly) FAL A SK P Twin KAL A SK P Twin LAL A SK P Single MAL A SK P Single Mounting assemblies for twin-mounted circuit breakers will only accept the same family and configuration of circuit breakers, i.e., FAL and FAL Schneider lectric D5A P1A Discount This document provided by Barr-Thorp lectric Co., Inc

13 Obsolescent Circuit Plugs For Obsolete lectronic Trip Circuit Class 666, 671, 677 These rating plugs are for electronic circuit breakers which are obsolete. Please refer to Digest 176 for PowerPact circuit breakers for new installations or replacement. M Micrologic Circuit Replacement rating plugs for circuit breakers manufactured before Micrologic. Table.25: Replacement Plugs for Pre- Micrologic Circuit Table.27: Replacement Plugs for Micrologic Circuit M Circuit Manufactured before Micrologic P Micrologic Circuit P Circuit Manufactured before Micrologic Circuit Manufactured Before Micrologic M P-G/PC-G Built before June 1, 1982 and all P/PC P-G/PC-G Built after June 1, 1982 Table.26: Frame Size 225 A 400 A 800 A 1200 A 1600 A 2000 A 1200 A 1600 A 2000 A 100 A M A M A M A M A M A M A M A M A M A M A P A P A P A P A P A P A P A P A P A P A P A P A P A PG A PG A PG A PG A PG A PG A PG A PG A PG A PG A PG A PG A PG Interchangeable Plug Kits for M, N, P and S Circuit with Full-Function Micrologic Trip System Manufactured Between December 1989 and September 1992 Circuit Breaker Frame Size e 100 A M2100RP 225 A 0 A M20RP 150 A M2150RP Micrologic 175 A M2175RP M Series A 250 A M4250RP 450 A M8450RP 800 A 500 A M8500RP 700 A M8700RP 600 A N120600RP 630 A N120630RP Micrologic 700 A N120700RP N Series A 800 A N120800RP 900 A N120900RP 1000 A N121000RP 600 A P120600RP 1200 A 700 A P120700RP 1000 A P121000RP 1200 A P121200RP 1000 A P161000RP Micrologic 1600 A 1200 A P161200RP P Series A P201000RP 1200 A P201200RP 2000 A 1400 A P201400RP 1600 A P201600RP 1800 A P201800RP 100 A S RP 125 A S RP 200 A 150 A S RP 175 A S RP 200 A S RP 200 A S RP 400 A 250 A S RP 300A S RP Micrologic S Series A S RP 450 A S RP 800 A 500 A S RP 700 A S RP 800 A S RP 1200 A 1000 A S RP 1200 A S RP 1600 A 1600 A S RP 2000 A 2000 A S RP e Contact your nearest local sales office for availability. S Micrologic Circuit Old New Multiplier Value RP040 ARP RP050 ARP RP056 ARP RP058 ARP RP060 ARP RP063 ARP RP067 ARP RP070 ARP RP075 ARP RP080 ARP RP083 ARP RP088 ARP RP090 ARP RP100 ARP Schneider lectric D5A D2 Discount This document provided by Barr-Thorp lectric Co., Inc

14 Obsolescent Circuit H/HB Circuit Class 590, H/HB circuit breakers are obsolete. Do not use on new applications. Limited service stock is available for replacement or fill purposes. Contact your local Sales Office for product availability. Table.28: Frame 100 A, Thermal Magnetic (480Y/277 Vac) Amp 1P 277 Vac 14 ka 120 Vac 65 ka 2P 480Y/277 Vac 14 ka 120/240 Vac 65 ka 3P 480Y/277 Vac 14 ka 240 Vac 65 ka Plug-On Bolt-On Bolt-On Bolt-On Wire Size (AWG) Availability Availability Availability Availability Al Cu Wire Temp. Requires 1 Space Requires 1 Space Requires 2 Spaces Requires 3 Spaces H/HB Circuit HB14015a HB24015 HB34015 (2) /75 o C 15 A HB (2) /75 o C HB HB (2) /75 o C HB14020a HB34020 (2) /75 o C 20 A HB (2) /75 o C HB (2) /75 o C HB (2) /75 o C 25 A /75 o C HB /75 o C 30 A HB HB HB /75 o C HB HB /75 o C HB /75 o C 35 A HB o C o C 40 A o C HB o C 45 A o C HB o C 50 A HB o C HB o C o C HB o C 60 A o C o C 70 A 4 2/0 4 2/0 75 o C 80 A 4 2/0 4 2/0 75 o C 90 A 4 2/0 4 2/0 75 o C 100 A HB24100b 4 2/0 4 2/0 75 o C 100 A HB /0 4 2/0 75 o C H/HB HID Circuit For Use on High Intensity Discharge Lighting Systems 15 A HB24015HID (2) /75 o C 20 A HB14020HIDa HB34020HID (2) /75 o C 25 A /75 o C 30 A HB34030HID /75 o C a UL Listed as SWD (switching duty) rated. b For use only in Series 3 or Series 1 panelboards. Contact your nearest local sales office for use in earlier series panelboards Schneider lectric D5A Discount This document provided by Barr-Thorp lectric Co., Inc

15 Obsolescent Circuit FJA Thermal-Magnetic Circuit FJ 3-pole circuit breakers are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. Table.29: Mechanical Lug Kit Information Circuit Breaker Application Standard Optional Al Lugs for Use with Al or Cu Wire FJ A FJ A Number of Wires Per Lug and Wire Range (1) 12 2/0 AWG Al or (1) 14 2/0 AWG Cu Kit Lugs Per Kit AL100FD 3 Table.30: Handle Accessories Circuit Breaker Type No. of Poles Handle Padlock Attachment (locks ON or OFF) FJ 1, 2 or 3 HPAFD 2012 Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

16 Obsolescent Circuit Q Metering Circuit Q circuit breakers are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. Table.31: Branch Circuit Table.31: Branch Circuit System Type 1Ø IN 1Ø OUT or 3Ø IN 1Ø3W OUT 200 A Max. 3Ø IN 3Ø OUT Branch Device Branch Circuit Breaker Availability 70 A Q270VH 80 A Q280VH 90 A Q290VH 100 A Q2100VH 125 A Q2125VH 150 A Q2150VH 175 A Q2175VH 200 A Q2200VH System Type 200 A Max. Branch Device Branch Circuit Breaker Availability 70 A Q370VH 80 A Q380VH 90 A Q390VH 100 A Q3100VH 125 A Q3125VH 150 A Q3150VH 175 A Q3175VH 200 A Q3200VH Schneider lectric D5A Discount This document provided by Barr-Thorp lectric Co., Inc

17 Obsolescent Circuit KD/KG Thermal-Magnetic Circuit Class 540 KD and KG circuit breakers are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. KDL and KGL Circuit Breaker 3P A Table.32: PowerPact K Frame 250 A, Thermal-Magnetic (240 Vac) Continuous 40 o C 2P, 240 Vac AC Magnetic Trip Settings D Interrupting Level G Interrupting Level Terminal Wire Range Hold Trip Availability Availability 100 A 00 A 1700 A KDL22100 KGL A 00 A 1700 A KDL220 KGL A 00 A 1700 A KDL22125 KGL A 00 A 1700 A KDL22150 KGL A 1400 A 2400 A KDL22175 KGL A 1400 A 2400 A KDL22200 KGL A 1400 A 2400 A KDL22225 KGL A 1400 A 2400 A KDL22250 KGL P, 240 Vac 100 A 00 A 1700 A KDL32100 KGL A 00 A 1700 A KDL320 KGL A 00 A 1700 A KDL32125 KGL A 00 A 1700 A KDL32150 KGL A 1400 A 2400 A KDL32175 KGL A 1400 A 2400 A KDL32200 KGL A 1400 A 2400 A KDL32225 KGL A 1400 A 2400 A KDL32250 KGL32250 Table.33: Mechanical Lug Kit Information AL250KD 6 AWG 350 kcmil Al or Cu AL250KD 6 AWG 350 kcmil Al or Cu Circuit Breaker Application Kit Catalog Number of Wires Per Lug Number and Wire Range Torque Lugs Per Kit Availability Standard Optional Al Lugs for Use with Al or Cu Wire AL250KD KDL, KGL A (1) 6 AWG 350 kcmil 300 lb-in (34 N m) 3 Cu Lugs for Use with Cu Wire Only CU250KD KDL, KGL (1) 6 AWG 350 kcmil 300 lb-in (34 N m) 3 Table.34: Handle Accessories Circuit Breaker Type Availability Handle Padlock Attachment (locks ON or OFF) KDL, KGL HPAKD Table.35: Interrupting s (ka) KDL 240 V Schneider lectric D5A Discount This document provided by Barr-Thorp lectric Co., Inc

18 Obsolescent Circuit NHL Thermal-Magnetic Molded Case Circuit Breaker Class NHL circuit breakers and related accessory products are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. NHL Circuit Breaker A Table.36: NHL Circuit Breaker (1200 A, 480 Vac) AC Magnetic Trip Settings s 2P 3P Low High 800 A 4000 A 8000 A NHF A 5000 A A NHF A 5000 A A NHF A 5000 A A NHF A 4000 A 8000 A NHL A 5000 A A NHL NHL A 5000 A A NHL A 5000 A A NHL NHL A 5000 A A NHL Standard Lug Kit Wire Range AL1200NA (4) kcmil Table.37: Mechanical Lug Kit Kit Circuit Breaker Number of Wires Per Lug and Wire Rangea Lugs Per Kit AL1200NA NH (4) kcmil 1 Table.38: Compression Lug Kit Kit Circuit Breaker Number of Lugs Per Terminal and Wire Rangea Lugs Per Kit VC1200NA5 NH (1) 2/0 AWG 500 kcmil 1 VC1200NA7 NH (1) kcmil Al or 500 kcmil Cu 1 a Unless otherwise specified, wire sizes apply to both aluminum and copper conductors. Table.39: Mechanical Accessories b Circuit Breaker Description No. of Poles HPANAb NH Handle Padlock Attachment 2, 3 NAHX NH Handle xtension 2, 3 Use with NAHX handle extension. Table.40: Control Wire Terminations Standard Package Quantity AL1200NAT Schneider lectric D5A Discount This document provided by Barr-Thorp lectric Co., Inc

19 Obsolescent Circuit S Circuit Breaker with Full-Function Trip Unit Class 678 S circuit breakers and related accessories are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. Table.41: S Circuit Breaker Sensor Size Plug Installed Fixed-Mounted Circuit Breaker ab Long-Time Short-Time Instantaneous Long-Time Short-Time Instantaneous w/ground Faultc Long-Time Short-Time Instantaneous Drawout Circuit Breaker ab Long-Time Short-Time Instantaneous w/ground Faultc Standard Interrupting 1200 A 1200 A SF361200LSMR SF363000LS SD363000LS 3000 A 3000 A SF363000LSG SD363000LSG SF363000LSMR SD363000LSMR ARP100 SF363000LSGMR SD363000LSGMR SF364000LSZ 4000 A 4000 A SF364000LSMRZ SF364000LSGMRZ SD364000LSGMR SF364000LSAMRZ High Interrupting 1200 A 1200 A SHF361200LSGMR ARP A 3000 A SHF363000LSMR a MR (Motor Ready) indicates 120 Vac spring charging motor only already installed. Does not include shunt close or shunt trip option. b Z indicates circuit breaker supplied without terminal connector kit. c Substitute (A) in place of (G) for ground-fault alarm (pick-up indication only) Schneider lectric D5A Discount This document provided by Barr-Thorp lectric Co., Inc

20 Obsolescent Circuit S Circuit Breaker Accessories Class S circuit breakers and related accessories are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement. Table.42: Field-Replaceable lectronic Trip Unit Kits (Replaceable by Field Services Only)a Long-Time Short-Time Instantaneous Trip Unit Function 400 A STU400LSGB 800 A STU800LSB 800 A STU800LSGB 1200 A STU1200LSB 1200 A STU1200LSGB 1600 A STU1600LSGB STU1600LSAB 2500 A STU2500LSGB 3000 A STU3000LSB 3000 A STU3000LSGB STU3000LSAB 4000 A STU4000LSB 4000 A STU4000LSGB a Used only with S circuit breaker Series 3B. c Fixed-mounted circuit breakers only. Does not include key interlock. Table.43: S Drawout Cell Keying Kit Cell Key Positions Table Cell Keying Frame Drawout Carriage Cell Key Position Availability Kit Size A B C D SCK A X X SCK A X X SCK A X X SCK A X X SCK A X X SCK A X X SCK A X X Table.44: Field-Replaceable Accessory Kits Spring Charging Motor Replacement Kit Shunt Close Replacement Kit Shunt Tripb Replacement Kit Undervoltage Tripb Replacement Kit Auxiliary Switchb Replacement Kit Description 120 Vac 24 Vdc 48 Vdc 125 Vdc 120 Vac 24 Vdc 48 Vdc 125 Vdc 120 Vac 24 Vdc 48 Vdc 125 Vdc Kit S3MOT120AC2 S3MOT125DC2 S3SC120AC2 S3SC024DC2 S3SC048DC2 S3SC125DC2 S3ST120AC2 S3ST024DC2 S3ST048DC2 S3ST125DC2 120 Vac 4 ac/dc 4 ac/dc add on 4 ac only 8 ac only S34DCB2 S34DCT2 S34AC2 S38AC2 Alarm Switchb 2 ac only S3AS2 Replacement Kit b Also field-installable on Series 3 and newer, and for Series 2 ground fault circuit breakers. Table.45: Field-Installable xternal Accessory Kits Description Padlock Attachment Close Button Cover Key Interlock Bracketc Series 1 Primary Injection Test Plug Series 2 Primary Injection Test Plug S Drawout Crank Fan Monitoring Switch Kit Kit S2PA S1CBC S1KI SPITK1 SPITK2 SDC S40FAN Long-Time Short-Time Instantaneous with Ground Fault Long-Time Short-Time Instantaneous with Ground Fault Alarm Table.46: Neutral Current Transformers Sensor Where Used S12NCT 800 S, SH S12NCT 1200 S, SH S30NCT 1600 S, SH S30NCT 2000 S, SH S30NCT 2500 S, SH S30NCT 3000 S, SH S40NCT 4000 S, SH lectric Joint Compound S drawout circuit breakers are supplied with factoryapplied joint compound on the plug-on connectors. The compound should not be removed because it contributes to the overall performance of the connection. Whenever one of these units is removed and reinstalled, the joint compound should be reapplied. PJC 83 is a two-ounce container of compound specially formulated for the S drawout connections. This compound MUST B USD ON S DRAWOUT CONNCTIONS. No other type of commercially available joint compound should be used. Table.47: lectric Joint Compound Used With SD Drawout Circuit PJC Schneider lectric D5A Discount This document provided by Barr-Thorp lectric Co., Inc

21 Molded Case Circuit M-Frame Thermal-Magnetic Circuit M-frame thermal-magnetic circuit breakers are obsolete. Please refer to Digest 176 for PowerPact molded case circuit breakers for new installations or replacement.. MAL/MHL 2P and 3p A Table.48: M-Frame Thermal-Magnetic, Individually-Mounted Circuit, 600 Vac 2P, 600 Vac, 250 Vdc 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A 900 A 1000 A AC Magnetic Trip Settingsa Standard Interrupting High Interrupting Terminal Wire Range Low High Availability Availability 1500 A 1750 A 2000 A 2250 A 2500 A 3000 A 3500 A 4000 A 4500 A 5000 A 3000 A 3500 A 4000 A 4500 A 5000 A 6000 A 7000 A 8000 A 9000 A A MAL26300 MAL26350 MAL26400 MAL26450 MAL26500 MAL26600 MAL26700 MAL26800 MAL26900 MAL MHL26300 MHL26350 MHL26400 MHL26450 MHL26500 MHL26600 MHL26700 MHL26800 MHL26900 MHL A 5000 A A MAL MHL P, 600 Vac, 250 Vdc 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A 900 A 1000 A a b 1500 A 1750 A 2000 A 2250 A 2500 A 3000 A 3500 A 4000 A 4500 A 5000 A 3000 A 3500 A 4000 A 4500 A 5000 A 6000 A 7000 A 8000 A 9000 A A MAL36300 MAL36350 MAL36400 MAL36450 MAL36500 MAL36600 MAL36700 MAL36800 MAL36900 MAL MHL36300 MHL36350 MHL36400 MHL36450 MHL36500 MHL36600 MHL36700 MHL36800 MHL36900 MHL A 5000 A A MAL MHL UL magnetic trip setting tolerances are ±25% for low and ±20% for high from nominal values shown. The AL100MA lug is the only lug available for the 1200 A MA and MH circuit breakers. AL900MA (3) 3/0 AWG 500 kcmil AL1000MAb (4) 1/0 AWG 350 kcmil AL900MA (3) 3/0 AWG 500 kcmil AL1000MAb (4) 1/0 AWG 350 kcmil Table.49: M-Frame Thermal-Magnetic, I-Line Construction Circuit, 600 Vac 2P, 600 Vac, 250 Vdcd 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A AC Magnetic Trip Settingsc Standard Interrupting High Interrupting Terminal Wire Range Low High Availability Availability 1500 A 1750 A 2000 A 2250 A 2500 A 3000 A 3500 A 4000 A 3P, 600 Vac, 250 Vdc 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A c d 1500 A 1750 A 2000 A 2250 A 2500 A 3000 A 3500 A 4000 A 3000 A 3500 A 4000 A 4500 A 5000 A 6000 A 7000 A 8000 A 3000 A 3500 A 4000 A 4500 A 5000 A 6000 A 7000 A 8000 A MA26300( ) MA26350( ) MA26400( ) MA26450( ) MA26500( ) MA26600( ) MA26700( ) MA26800( ) MA36300 MA36350 MA36400 MA36450 MA36500 MA36600 MA36700 MA36800 MH26300( ) MH26350( ) MH26400( ) MH26450( ) MH26500( ) MH26600( ) MH26700( ) MH26800( ) MH36300 MH36350 MH36400 MH36450 MH36500 MH36600 MH36700 MH36800 AL900MA (3) 3/0 AWG 500 kcmil AL900MA (3) 3/0 AWG 500 kcmil UL magnetic trip setting tolerances are ±25% for low and ±20% for high from nominal values shown. 2P circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog numbers. See Phase Options table. Table.50: Interrupting s Voltage MA/MAL MH/MHL 240 Vac 42 ka 65 ka 480 Vac 30 ka 65 ka 600 Vac 22 ka 25 ka Accessories Page -28 OptionalLugs Page -23 Dimensions Page -5 nclosures: see Digest Section Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

22 Circuit Breaker Accessories Auxiliary Switch Contact Configuration Color Code: "A" Contact - Yellow Leads "B" Contact - Blue Leads Common-Striped Leads A 1A/1B Circuit Breaker Closed A Circuit Breaker Open or Tripped B B 1A Alarm Switch Configuration Color Code: Red Leads Circuit Breaker Open or Closed 1B Alarm Switch Configuration Color Code: Red Leads Circuit Breaker Tripped Field-Installable Accessories Field-Installable lectrical Accessories Complete field-installable accessory catalog number by inserting suffix from Digest page 7-36 between the parentheses in the catalog numbers shown in the table below. (xample: LA212) See Digest page 7-36 for accessory pricing; add 20% to factory-install fieldinstallable devices. Table.51: Circuit Breaker Field-Installable Accessories for Thermal-Magnetic and lectronic Trip Circuit Shunt Trip Ground-Fault Shunt Tripa Undervoltage Trip Auxiliary Switches Alarm Switch MA, MH Series 2 MA1( ) MA1G MA1 ( ) MA1( ) Factory-Installed Only Center Pole M, MX Factory-Installed Only Factory-Installed Only Factory-Installed Only Factory-Installed Only Factory-Installed Only NA, NC, N, NX Series 1, 2, 3 NA1( ) NA1( ) NA1( ) NA1( ) NA1( ) PA, PH, PC Series 4 PA1( ) Factory-Installed Only PA121 PA1( ) Factory-Installed Only P, PX Series 4, 5, 6 PA1( ) Factory-Installed Only PA121 PA1( ) Factory-Installed Only a Used with obsolete GP Ground-Censor system or add-on ground-fault modules. Table.52: Accessory Mounting Locations MA, MH Series 2 circuit breakers or newer = Fieldinstallable accessories M/MX circuit breakers = Not field-installable accessories Circuit Breaker Tripped Undervoltage Trip Wiring Diagram Circuit Breaker Open or Closed L R UVR Brown Brown Shunt Trip Wiring Diagram Brown Wires To Be Connected To Control Power R2 NA, NC, N, NX circuit breakers - FIeld-installable accessories L port and R port will accept shunt trips, alarm switches and UVRs; R2 port will accept auxiliary switches. Maximum of one device per port. Shunt Trip Black Black Black Wires To Be Connected To Control Power L1 L2 L R1 R2 R1 PA, PH, PC, P, PX Series 4 circuit breakers or newer = FIield-installable accessories. L1 a nd L2 or R1 and R2 port combinations are required to mount a single shunt trip. Both L2 and R2 ports will accept a UVR. Both L1 and R1 ports will accept auxiliary switches. If alarm switch is factory installed in PA or PC circuit breaker, it will be installed in R2 port. For a P or PX circuit breaker, the alarm switch will be factory installed in L2 port Schneider lectric This document provided by Barr-Thorp lectric Co., Inc

23 Circuit Breaker Accessories Mechanical Lug Information AL900MA AL800MA7 AL1000MA AL2500PA Table.53: Mechanical Lug Kit Information Circuit Breaker Application Lugs (Number of Wires Per Lug ) Availability Wire Rangea Per Standard Per Kit Optional Kit Al Lugs for Use with Al or Cu Wire LC, LI, L, LX, LXI (1) kcmil AL600LI7 1 MA, MH A (3) 3/0 AWG 500 kcmil AL900MA 1 MA, MH A (2) kcmil AL800MA7 1 MA, MH A (4) 1/0 AWG 350 kcmil AL1000MA 1 M, MX A (1) 6 AWG 350 kcmil AL250M 3 M, MX A (1) kcmil AL400M7 1 M, MX A (2) kcmil AL800MA7 1 M, MX A M, MX A (3) 3/0 AWG 500 kcmil AL900MA 1 M, MX A (4) 1/0 AWG 350 kcmil AL1000MA 1 NA, NC, N, NX A (4) 3/0 AWG 600 kcmil AL1200N6 1 PAF, PHF, PF, PXF, PCF A (1) 1/0 AWG 750 kcmil AL2500PA 2 Cu Lugs for Use with Cu Wire Only c MA, MH A (3) 3/0 AWG 500 kcmil Cu CU1000MA 1 M, MX A (1) 4 AWG 250 kcmil Cu CU250M 3 M, MX A (3) 3/0 AWG 500 kcmil Cu CU1000MA 1 NA, NC, N, NX A (4) 3/0 AWG 600 kcmil Cu CU1200N6 1 a Unless otherwise specified, wire sizes apply to both aluminum and copper conductors. b For use in the OFF end only, when the OFF end is the load end. c Use suffix 8002 for factory-installed Cu lugs. (20% adder.) Compression Lug Kits Table.54: Field-installable Compression Lug Kitsa Circuit Breaker Type Wire Rangeb Dimension A (In) Max. Lugs Per Terminal Lug Qty. Per Kit Availability Aluminum Compression Lug Kits MA, MH 2/0 AWG 500 kcmil VC600MA kcmil VC800MA7 2 M2, MX2 4 AWG 300 kcmil VC250M kcmil VC250M35 3 2/0 AWG 500 kcmil VC400M5 1 M4, MX kcmil Al or 500 kcmil Cu VC400M7 1 2/0 AWG 500 kcmil VC600MA5 2 M, MX, MA, MH kcmil Al or 500 kcmil Cu VC800MA7 2 2/0 AWG 500 kcmil VC1200N5 4 NA, NC, N, NX kcmil Al or 500 kcmil Cu VC1200N7 4 PAF, PHF, PCF, PF 2/0 AWG 500 kcmil c 6 8 VC2000PA5 4 2/0 AWG 500 kcmil c 6 8 VC2500PA7 4 Copper Compression Lug Kits M4, MX kcmil Cu CVC400M5 1 M, MX kcmil Cu CVC600MA5 2 NA, NC, N, NX kcmil Cu CVC1200N kcmil Cu CVC1200N7 4 a See instruction bulletins for recommended tools. b Unless otherwise specified, wire sizes apply to both aluminum and copper conductors. c All P-frame circuit breakers require terminal pads for mounting lugs of any type. Power Distribution Connectors (PDC) for Circuit for Field Replacement of Mechanical Lugs Can be used for multiple load connections on one circuit breaker. Use in place of standard distribution blocks to save space and time. Field-installable kits, including tin-plated aluminum connectors and all necessary mounting hardware are available for Square D FA, LA and Q4-frame molded case circuit breakers. Connectors are UL Listed: For use on load end of circuit breaker only For use in UL508 Industrial Control applications only For use in UL 1995/CSA C22.2 No. 236 heating and cooling equipment For copper wire only Table.55: PDC Lugs Use With Circuit Breakerd Cicuit Breaker Wires Per Terminal & Wire Rangee Cu Lug Quantity Per Kit Dimension A (i.) Availability MAL, MHL, ML, MXL A (6) 12 2/0 AWG Cu PDC6MA (12) 14 4 AWG Cu PDC12MA d Not for use with I-Line circuit breakers. e When using fine stranded wire, increased cross sectional area may cause maximum wire size to be reduced. f OFF end only when OFF end is the load end Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

24 lectronic Products Micrologic Series 2/3/A/B Trip Unit Test Sets Class NOT: Listed below are the catalog numbers and the components required for testing the entire family of Micrologic trip systems. The listing includes obsolete series trip systems. Micrologic Series B Trip Systems Identified by label on front of trip unit (L/LX/LXI, M/MX, N/NX and P/PX circuit breaker 9/92 to present) (S circuit breaker 10/92 to present) This is the latest series of standard (LX/LXI, MX, NX and PX) and full-function (L, M, N, P and S) Micrologic trip systems. Table.56: Universal Test Set Description Universal Test Set includes the following: 1. Self-test module (CBTMT) 2. Standard and full-function Micrologic Series B module (CBTMB) includes rating plug adapter 3. Power cord 4. Ribbon cable for making the connection from the test set to the rating plug adapter 5. Instruction manual For those customers who already own the Universal Test Set and want to test the latest standard and full-function (Series B) trip systems, all that is needed is Micrologic Series B module (CBTMB). Included is the rating plug adapter and instruction manual. Replacement ribbon cable and rating plug adapter for CBTMB Long-time and ground-fault memory reset module (Series B lectronics) UTS3 CBTMB CBTMBRK MTMB Micrologic Series 3 and Series A Trip Systems Identified by two rows of rotary switches (M/MX, N/NX and P/PX circuit breakers /89 to 9/92) (S circuit breakers 5/90 to 10/92) For those customers who already own the Universal Test Set (CBTU1 or UTS3) and want to test these earlier series Micrologic trip systems, see the following chart. Table.57: Micrologic Series 3 and Series A Circuit Breaker Test Module Circuit Breaker Test Module Includes rating plug adapter and instruction manual Replacement ribbon cable and rating plug adapter for CBTM4A CBTM4A CBTM4RK Micrologic Series 2 Trip Systems Identified by only one row of rotary switches Micrologic Series 2 Test Modules are obsolete and no longer available. Table.58: Micrologic Series 2 Circuit Breaker Test Module Circuit Breaker Test Modules Availability S (5/85-5/90) includes rating plug adapter and instruction pages CBTM1 Replacement ribbon cable and rating plug for CBTM1 CBTM1A M, P (4/85-/89) CBTM2 obsolete, no longer available CBTM2 M, N, P (10/86-/89) includes rating plug adapter and instruction manual CBTM3 Replacement ribbon cable and rating plug for CBTM3 CBTM3A Table.59: Micrologic Series 1 Trip Systems for Circuit Manufactured Before Micrologic Trip System M/P (8/78-4/85) Identified by slide type switches instead of rotary switches. The very first series M and P electronic trip circuit breakers offered by Square D. S (7/83-5/85) The very first series of S electronic trip circuit breakers had rotary switches and can be identified by a three-digit serial number. Test Set Test Set Test Set Note: For trip systems of this type that require testing, contact Technical Services toll free at Table.60: Neutral Current Transformers Availability Sensor Where Used M25CT2 M4CT2 M8CT2 250 A 400 A 800 A MXL,ML N12CT A NXL,NL P12CT2 P16CT2 P20CT2 P25CT A 1600 A 2000 A 2500 A PXF, PF Schneider lectric D2 Discount This document provided by Barr-Thorp lectric Co., Inc

25 GFM250 Ground-Fault Protection The Micrologic ground-fault module (GFM) is a UL Listed circuit breaker accessory for equipment protection. It is a combination ground-fault relay and ground-fault sensing device. Micrologic Add-On Ground-Fault Module Features: Used in combination with the FA, KA, FC, KC, FI, and KI type circuit breakers with a ground-fault shunt trip factory installed (add the suffix G to the circuit breaker) Adjustable ground-fault pickup levels Adjustable ground-fault time delays Integral ground fault push-to-test feature and ground-fault indicator All GFMs supplied for I-Line mounting, easily convertible to unit mount by removing the I-Line brackets Neutral current transformer is supplied for 3-phase 4-wire applications. Refer to instructions for proper installation Zone-selective interlocking capability is standard with upstream Micrologic trip system circuit breakers. The GFM can also be zone interlocked with the GC ground-fault system by using a restraint interface module.see Supplementary Digest 120 Vac control power is required for integral test feature. Meets NC (c) NOT: Ground-fault modules cannot be reverse fed. Table.61: Module/nclosure Selection Chart Companion nclosure Space Required Ground-Fault Circuit Pickup Breaker I-Line Individual Availability Adjustment Prefix Switchboard nclosure a Range FAL, FHL, FCL, FA, GFM100FA LA KA A FH, FC FI GFM100FI LA A Not Available KAL, KHL, KI, KA, GFM250 LA LA A KH, KC a Use NMA 1 or 3R enclosures only. See page -5 for dimensions. Micrologic Add-On Ground-Fault Module (GFM) RIM32 Restraint Interface Module Table.62: ZSI Combinations Circuit Breaker Series a GFM is an output device only. Class 931, 940, 960 The RIM32 Restraint Interface Module is used to interface the restraint signals between various Square D Micrologic circuit breakers, Micrologic ground-fault modules, and GC-100 ground-fault protection systems. The restraint interface module operates on either 120 or 240 Vac, 50/60 Hz. The module is protected by a 1/4 A fuse. Allowable ZSI combinations are shown in Table.62. (Series numbers for current design circuit breakers end in B, for example N Series 3B.) For double-ended or larger systems, or systems which contain devices from different columns in Table.62, contact your local Sales Office for combination information. If more inputs or outputs are needed, another restraint interface module is necessary. Contact your local Sales Office for information on multiple module installations. NOT: The maximum distance between devices is 1000 ft. (305 m). Table.63: RIM32 ZSI Combinations (Where All Inputs Driven Are Same Column) Inputs Output RIM32 S 2 (Ground Fault) S 2 (Short Time) M 3, N1, P 4 M 4 & 5, N 2 & 3 P 5 & 6, S 3 M 5A, N 3A, P 6A, S 3A L 1B, M 5B, N 3B, P 6B, S 3B S 2 (Ground Fault) 50 R R R R R 50 S 2 (Short Time) 1 R R R R R 50 M 3, N1, P 4 50 R R 50 M 4, 5 & 5A, N 2, 3 & 3A, P 5, 6 & 6A, S 3, 3A 50 R R R 14 L 1B, M 5B, N 3B, P 6B, S 3B 50 R 10 1 R 26 R 44 GC 100 R R R R R R 7 50 GFMa R 10 RIM # Maximum inputs without RIM32. Self-restraint counts as one input. R RIM32(s) required to restrain any devices. Note: Present design. Invalid combination. GC100 RIM 32 OUT GND No. 4 Ground Fault Restraint OUT GND No. 5 Short Time Restraint OUT GND No. 6 Restraint OUT GND GC-100 Ground Fault Restraint COM 240 Vac OUTPUTS No. 1 Ground Fault Restraint IN GND CAT. NO. RIM32 No. 2 Short Time Restraint IN GND INPUTS No. 3 Restraint IN GND PUSH TO TST GC-100 Ground Fault 1/4 AMPR Restraint 120 IN GND COM Vac 2012 Schneider lectric D2 D5A Discount This document provided by Barr-Thorp lectric Co., Inc

Section 11. Obsolescent and Obsolete Circuit Breakers. Table of Contents. Obsolescent and Obsolete Types. Obsolescent Circuit Breakers

Section 11. Obsolescent and Obsolete Circuit Breakers. Table of Contents. Obsolescent and Obsolete Types. Obsolescent Circuit Breakers Table of Contents Section Obsolescent and Obsolete Circuit Obsolescent and Obsolete Types Circuit Breaker Availability -2 Pictorial and Dimensions -4-5 Obsolescent Circuit F-Frame Thermal-Magnetic Circuit

More information

Obsolescent Circuit Breakers Molded Case Circuit Breakers Circuit Breaker Accessories Electronic Products 11-42

Obsolescent Circuit Breakers Molded Case Circuit Breakers Circuit Breaker Accessories Electronic Products 11-42 Table of Contents Section 11 Obsolescent and Obsolete Circuit Breakers Obsolescent and Obsolete Types 11-2 Circuit Breaker Availability 11-2 Pictorial and Dimensions 11-4 11-6 PowerPact D-Frame Circuit

More information

Thermal-Magnetic For Mining Applications Class 600

Thermal-Magnetic For Mining Applications Class 600 Square D www.squared.com FOR CURRENT INFORMATION Molded Case Circuit Breakers for Mining s These circuit breakers with the properly selected trip range provide protection for trailing cables in compliance

More information

PowerPact Circuit Breakers 3-3. PowerPact Automatic Switches 3-6. Molded Case Circuit Breakers 3-7. Circuit Breaker Accessories 3-23

PowerPact Circuit Breakers 3-3. PowerPact Automatic Switches 3-6. Molded Case Circuit Breakers 3-7. Circuit Breaker Accessories 3-23 Table of Contents Section 3 Molded Case s and Enclosures PowerPact s 3-3 PowerPact H- and J-Frame s 3-2 3-3 PowerPact L-Frame s 3-4 PowerPact D-Frame s 3-5 PowerPact Automatic Switches 3-6 PowerPact D-frame

More information

Thermal-Magnetic Circuit Breakers. Electronic Trip Circuit Breakers. Breaking Capacities 9-7 Circuit Breaker Dimensions 9-8

Thermal-Magnetic Circuit Breakers. Electronic Trip Circuit Breakers. Breaking Capacities 9-7 Circuit Breaker Dimensions 9-8 Table of Contents Section 9 International Circuit Breakers Thermal-Magnetic Circuit Breakers SF and SL Circuit Breakers, IC Rated 415/240 Vac Max. 9-2 lectronic Trip Circuit Breakers P-frame, 3P, Micrologic

More information

For the most up-to-date information

For the most up-to-date information www.square.com or the most up-to-date information Thermal-magnetic Molded ase ircuit reakers, 2 mpere rame lass 5,, 734, 8 IL3 JL 3-pole circuit breaker -frame, Thermal-magnetic ( Vac) mpere Magnetic Trip

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

The UL listed heart of the LynTec Lighting Control and Sound Sequencing Panels

The UL listed heart of the LynTec Lighting Control and Sound Sequencing Panels The UL listed heart of the Lighting Control and Sound Sequencing Panels Handle functions as a normal circuit breaker. When switched off or tripped due to overload, the remote control will not turn on power.

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No.

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No. Square D Breakers American International Marketing P.O. Box 9133 Portland OR 97291-033 Closeout #1279-Square-D-Breakers Square D HOM230CP 30A DP Circuit Breaker (NEW) Square D #HOM230CP 30A DP Circuit

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers Table of Contents Section 7 Model Motor Control Centers Motor Control Centers Structure and Unit Features 7- Merchandised Units General Information 7- Combination Starters with Motor Circuit Protector

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems.

More information

Quality and Innovation for Global Solutions

Quality and Innovation for Global Solutions Commercial and Industrial Circuit Breakers for OEM Applications Quality and Innovation for Global Solutions Make the most of your energy SM One World Source The Opportunity: The world is opening up to

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Type MP-T Type MP-HT Type MP-MT

Type MP-T Type MP-HT Type MP-MT CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List

More information

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950. Vol. 1, Ref. No. [0559] - Amperes M-Frame 12-93 % Rated Digitrip OPTSM s with interchangeable Rating Plugs Order as individual components: Frame (which includes Trip Unit), Rating Plug, Terminals. Table

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Enhancing Short Circuit Selective Coordination with Low Voltage Circuit Breakers

Enhancing Short Circuit Selective Coordination with Low Voltage Circuit Breakers Data Bulletin 0100DB0403R5/05 05/2005 Cedar Rapids, Iowa, USA Enhancing Short Coordination with Low Voltage s Retain for future use. INTRODUCTION DEFINITIONS ASSUMPTIONS CIRCUIT BREAKER BASICS The purpose

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable Trip unit type Defined by the 5th character of the catalog number B Thermal-magnetic,

More information

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F -220 Mining Service Circuit s Table -395. Interrupting Capacity Ratings Circuit Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Volts dc 240 480 1000Y/577 250 E 2 L E 2 LM 65,000 35,000

More information

22.000A IR. Catalog Number. Price $

22.000A IR. Catalog Number. Price $ Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION Instruction Bulletin Bulletin No. 0006-39-03 May 997 Raleigh, NC, USA Enclosed ALTISTART 6 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION This bulletin is a supplement to

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

TeSys Motor Starter Solutions for the North American Market

TeSys Motor Starter Solutions for the North American Market TeSys Motor Starter Solutions for the North American Market Data Bulletin 8536DB0901 Tesys Motor Starter Solutions 8536DB0901 Table of Contents 11/2009 Table of Contents Introduction... 3 Overview of U.S.

More information

General data 5/37. Overview

General data 5/37. Overview General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available

More information

Digest 176. Supplemental and Obsolescence. Global Specialist in Energy Management. Power. Management. Process & Machines. Management.

Digest 176. Supplemental and Obsolescence. Global Specialist in Energy Management. Power. Management. Process & Machines. Management. 2012 Supplemental and Obsolescence Digest 176 Global Specialist in Energy Management Power Management Process & Machines Management IT/Server Room Management Building Management Security Management The

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame Vol. 1, Ref. No. 10499) Product Selection Table 12-56. Types 12-33 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

THQL1120AF2 THQL1120AF2 Arc Fault BRKR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001 2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

System pro M compact Miniature Circuit Br eakers Description Features

System pro M compact Miniature Circuit Br eakers Description Features System pro M compact Miniature Circuit reakers S0 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame 12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. - Product Selection M-Frame Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

VL Circuit Breaker DG 150A frame

VL Circuit Breaker DG 150A frame VL Circuit Breaker DG 150A frame Breaker type Defined by the 3rd character of the catalog number G Global (UL, CSA, IEC, CE, CCC), interchangeable K Global, non-interchangeable W Global, 100% rated, non-interchangeable,

More information

Intelligent Choice for Prestigious Buildings

Intelligent Choice for Prestigious Buildings Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

Multistandard offer for OEM applications. Single solution source for business without borders

Multistandard offer for OEM applications. Single solution source for business without borders Multistandard offer for OEM applications Single solution source for business without borders 1 Improving customer satisfaction means producing industrial machines that are compliant to international standards,

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Model 6 Motor Control Centers Catalog 8998CT9701R07/ Class 8998

Model 6 Motor Control Centers Catalog 8998CT9701R07/ Class 8998 Catalog 8998CT9701R07/09 2009 Class 8998 CONTENTS Description............................................. Page Product Description.......................................... 7............................

More information

LOW VOLTAGE SWITCHGEAR

LOW VOLTAGE SWITCHGEAR LOW VOLTAGE SWITCHGEAR S-N Motor Control Mitsubishi Electric s S-N Series contactors are perfect for the control of 3 phase power, either for the direct control of a motor, to supply power to a drive or

More information

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac)

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac) MINITUR N MOL S IRUIT RKRS PowerPact ircuit reaker JL 3P ircuit reaker QL 2P 0 250 QL 3P 0 250 Tale.46: mpere - and Q-rame ircuit reakers lass 034, 0500 / Refer to atalogs: 034T0201, 0500T902 PowerPact

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940 Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information