3 Phase Voltage Imbalance
|
|
- Pauline Shields
- 5 years ago
- Views:
Transcription
1 3 Phase Voltage Imbalance Keep in mind when reading ANY article about electrical theory or application is that it only scratches the surface of the topic. You can dedicate years of your life to understanding electrical theory and design the way many engineers do and still know just enough to be dangerous. In HVAC we rarely need to have a DEEP understanding of electrical design but there are a few cases where a little understanding can go a long way to identifying issues before they cause trouble and that is the intent of this short article. What is Three Phase Power? Power is generated at the utility in three phases that are 120 degrees out of phase with one another at 60hz (Hertz). This simply means that 60 times per second each individual leg of power makes one peak and valley (a full circle), and all three of the phases together split the cycle into thirds (trisect).
2 This video is the best visual demonstration I have seen of three-phase power and how it works. What Does an HVAC Tech Need to Know About Three Phase Power? Three-phase motors don t require a run capacitor because the 120-degree phase difference is ideal for efficiently spinning a motor so a start winding and phase shifting capacitor isn t needed. The biggest concern for the techs and installers with three phase is getting the phasing correct so that motors run in the correct direction. While this doesn t matter for reciprocating compressors it is important for condenser fans and blowers and it is absolutely CRITICAL for scroll and screw compressors. Changing the direction of rotation is just as simple as swapping any two phases.
3 Keep in mind when installing replacement parts and equipment that if you keep the phases connected in the same way you will generally be in good shape. It is still a good practice to use a phase rotation indicator like the one above to confirm proper rotation. In most cases, clockwise phase rotation is what you are looking for but I m sure there are exceptions to that. Alternatively, you can disconnect the compressor that could be damaged by improper phasing and start up the blower to see if it runs the correct direction before bringing the compressor(s) online. One caveat is that when motors use a VFD (variable frequency drive) the phase rotation will automatically correct making them an unreliable test in those cases. Balancing Phases Electricians are responsible for balancing the amperage of single-phase loads (both 120v single leg and 208v two leg loads typical on a wye three-phase system) both so the neutral doesn t carry high amperage on the 120v loads and so the one leg of power doesn t carry significantly more or less load than the other two. As the amperage load on a particular phase goes up, there is more opportunity for voltage drop depending on the size of the load, size of the transformer and service feeding the space and well as wire size and connection quality. This can become a challenge when there is a mix of single phase outlets, 208v appliances, and three-phase equipment. Let s say someone connects a bunch of space heaters on phase A, as well as a few smaller HVAC systems between phases A and B and almost nothing on phase C. If you have a large RTU that uses three-phases phase C will tend to have less load and therefore higher voltage while the load on phases A and B will fluctuate based on when the smaller systems and space heaters go on and off. This can cause overheating of conductors and damage but it can
4 also cause voltage imbalance which is a real cause for concern for an HVAC technician. 3 Phase Voltage Imbalance Voltage imbalance is a motor killer. It causes poor motor performance and increased winding heat which leads to premature failure. In the case of HVAC blowers and compressors, this additional heat ends up in either the
5 refrigerant or the air which must then be removed, further decreasing efficiency. To test for three-phase imbalance always check from phase to phase not from phase to ground. You simply check the voltage from each of the three phases to one another and find the average (add all three and divide by three). Then compare the reading that furthest from the average and find the % of deviation. For most of you I know that sounds like a giant pain so we made this easy calculator for you. The US Department of Energy recommends that the voltage imbalance be no more than 1% while other industry sources say up to 4% is acceptable. In general, you will want to make SURE the imbalance is below 4% and work to rectify anything over 1%. What Can I Do About It? You want to first look for the obvious. Melted wires, loose terminals and lugs, undersized wire, pitted contacts, poor disconnect fuse contact etc Obviously, if you aren t licensed or allowed to open a panel you won t always be able to fully rectify the issue yourself but you can go a long way towards the diagnosis. When checking voltage it is generally best to do it with the system running as close to the motor you are checking as possible. This is the actual voltage the motor is seeing and is what matters to the operation of the motor. You can then test back towards the distribution point, if you see a big increase in voltage as you test back towards the source you know you found a voltage drop and a cause or contributor to the issue. From there the issues of amperage load imbalance in the panel, service size and utility issues must be considered once all the basics are covered. Most of all, if the imbalance is severe (over 4%) you don t want to leave your motors running
6 or you risk damage and expensive repairs. Bryan
Beware of Ghost Voltage
Beware of Ghost Voltage This article serves two purposes. First, it is an article for technicians who have heard of the dreaded ghost voltage but never understood why it happens. Second, for my own apprentices
More informationWhy is the Breaker Tripping?
Why is the Breaker Tripping? Breakers are designed to trip anytime the circuit draws a current above the rating for a period of time. The time the breaker takes to trip is a function of how high the circuit
More informationI m going to come out and say it so you keep reading. What you were taught about hard start kits decreasing inrush amperage is wrong.
Start Capacitor & Inrush, Facts & Myths Part 4 Now is the part where we get specific about Start capacitors and inrush. If you haven t read the first three parts please do so before reading this one or
More informationElectric Motor Controls BOMA Pre-Quiz
Electric Motor Controls BOMA Pre-Quiz Name: 1. How does a U.P.S. (uninterruptable power supply) work? A. AC rectified to DC batteries then inverted to AC B. Batteries generate DC power C. Generator, batteries,
More informationTroubleshooting Guide for Okin Systems
Troubleshooting Guide for Okin Systems More lift chair manufacturers use the Okin electronics system than any other system today, mainly because they re quiet running and usually very dependable. There
More informationEDITOR'S NOTE: This article replaces "Use PGM FI Data List to Help Troubleshoot Inoperative A/C," issued in June 2012.
2001 Honda Civic 1.7L Eng LX TROUBLESHOOTING AN INOPERATIVE A/C TECHNICAL SERVICE BULLETIN Reference Number(s): 13 080J, Date of Issue: August, 2013 HONDA: '00 and later models with A/C APPLIES TO: '00
More informationPREVIEW ONLY. Course 106 INSTRUCTOR GUIDE. HVAC Systems Introduction and Overview. Module 1: Overview of Rail Car HVAC and General Safety Procedures
Course 106 HVAC Systems Introduction and Overview Module 1: Overview of Rail Car HVAC and General Safety Procedures INSTRUCTOR GUIDE Table of Contents CHECKLIST FOR INSTRUCTION... 3 SUPPLIES, AUDIO-VISUAL
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationWorking Principle of Power Saver as per Manufacture:
Analysis the Truth behind Household Power Savers Introduction: A House hold power saving devices has recently received a lot of attention from both consumers and manufacturers. It is generally used in
More informationTroubleshooting Guide for Limoss Systems
Troubleshooting Guide for Limoss Systems NOTE: Limoss is a manufacturer and importer of linear actuators (motors) hand controls, power supplies, and cables for motion furniture. They are quickly becoming
More informationHOW TO USE A MULTIMETER, PART 4: MEASURING CURRENT (AMPERAGE)
HOW TO USE A MULTIMETER, PART 4: MEASURING CURRENT (AMPERAGE) By: Rob Siegel First, we discussed how to use a multimeter for measuring voltage, or simply verifying that voltage is present. Last week, we
More informationWelcome to the SEI presentation on the basics of electricity
Welcome to the SEI presentation on the basics of electricity 1 Electricity is a secondary energy source, meaning that it is produced from other, primary, energy sources. There are several primary sources
More informationBoardworks Ltd Mains Electricity
1 of 22 Boardworks Ltd 2016 Mains Electricity Mains Electricity 2 of 22 Boardworks Ltd 2016 Direct current 3 of 22 Boardworks Ltd 2016 There are two main types of electric current: direct current (DC)
More informationA Fresh Take. on Chrysler s Pressure. Figure 1
A Fresh Take on Chrysler s Pressure Boost System BEYOND THE BASICS A Fresh Take on Chrysler s Pressure by Dennis Madden members.atra.com Boost System Boost Valve Exhaust Boost Tube Figure 1 Ifind some
More informationNorth America Phase Converters & Electrical Supply
North America Phase Converters & Electrical Supply OPERATION AND INSTALLATION MANUAL ROTARY PHASE CONVERTERS (Models PL, UL & CP) 240 VOLTS WARNING: To reduce the risk of injury, the user must read and
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these
More informationInstall a module ME or MT
Install a module ME or MT.5.202 Build a converter with a Booster module. ME modules deliver unbalanced three-phase voltages, sufficient for machines with threephase motors. MT produces balanced three-phase
More informationTempest Tech-Tip 0813
August 2013 Tempest Tech-Tip 0813 Light My Fire Background Without a good spark, spark plugs can t get the job done well. How do you keep good sparks coming, so your spark plugs can light your fire with
More informationWhy and how to adjust a TXV / TEV
Why and how to adjust a TXV / TEV As we talked about in an earlier podcast, a TXV is designed to maintain a specified and constant superheat at the outlet of the evaporator coil. It does this through a
More informationProgram IV: ProStar TM. Performance A/C International. Series. Study Guide Performance A/C Program IV: International ProStar Series TMT
Performance A/C International A N AV I S TA R C O M PA N Y Program IV: ProStar TM Study Guide TMT-160701 Series Study Guide Performance A/C Program IV: International ProStar Series TMT-160701 2007 International
More informationHydraulic Slide Starts and Stops
Hydraulic Slide Starts and Stops This guide is intended to assist Heartland Owners in understanding why the Hydraulic Pump may start and stop while operating the slideouts. Who created this document? Important
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following models: 9000 Series 6000 Series To ensure that the system is installed properly, provide your electrician with these instructions.
More informationFront Drive System - Big Block Chevy Installation Instructions Big Block Chevy with AC & with PS
Front Drive System - Big Block Chevy Installation Instructions Big Block Chevy with AC & with PS All American Billet Store (800) 764-0926 www.allamericanbilletstore.com Items needed for install Jack Jack
More informationSERVICE SHOP NOTES. Use ohmmeter to check the resistance between the leads.
SERVICE SHOP NOTES LIMA MAC SELF VOLTAGE REGULATED GENERATORS Troubleshooting Tips Symptom: Engine bogs down or stalls even at no load. Problem: Main stator has one or more taps wound or connected incorrectly.
More informationINDUCTROL. Voltage Regulator CPO 97.09F. updated 03/09
INDUCTROL Voltage Regulator CPO 97.09F updated 03/09 Are voltage ups & downs costing you money? GE INDUCTROL voltage regulators can eliminate irregularities VOLTAGE ups and downs may be costing you thousands
More informationMASTERsine Inverter PXA Series Installation Guide
Backup Power System Expert TM MASTERsine Inverter PXA Series Installation Guide Important Safety Instructions IMPORTANT: Read and save this Installation Guide for future reference. This chapter contains
More informationMOTORS, VOLTAGE, EFFICIENCY AND WIRING. A Deeper Understanding
MOTORS, VOLTAGE, EFFICIENCY AND WIRING A Deeper Understanding An understanding of motors, voltage, efficiency, wiring, and how these concepts fit together cohesively is important for several reasons. Greater
More informationPower Factor Correction
AE9-1249 R10 August 2008 Power Factor Correction Index Page 1. Introduction... 1 2. Electrical Fundamentals... 1 3. Electrical Formulas... 2 4. Apparent Power and Actual Power... 2 5. Effects of Poor Power
More informationTECHNICAL BULLETIN JUNE 2015 HVA/C COMMON PROBLEMS, QUICK FIXES
TECHNICAL BULLETIN JUNE 2015 This article was written by Vanessa Atwell, contributing editor of Auto Body Repair Network (ABNR) Magazine. Pet Rudloff also contributed to this article. It was published
More informationPre-Trip Inspection 2017 PRESENTED BY DON WEST
Pre-Trip Inspection 2017 PRESENTED BY DON WEST Everyone knows how to do a pre-trip We do it everyday I ve been driving for twenty years Complacent Were they grandfathered in? Starting your Pre-Trip As
More informationElectrical Energy and Power Ratings
Section 1 - From the Wall Socket Electrical Energy and ower Ratings Batteries and the mains are sources of electrical energy. Electrical appliances can then convert this into other forms of energy. e.g.
More informationGLOVE BOX CHECK IT GUIDE
GLOVE BOX CHECK IT GUIDE When it comes to road safety, one thing you can control is proper maintenance of your vehicle. Keep this simple guide in your glove box & use it to complete quick, regular checks
More informationWARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual
FinishPro 390/395 Airless/AirAssisted Sprayer Repair Electrical Manual First choice when quality counts. Rev. B 10/11 /07 FinishPro 395 3.00 ti9026a Red Yel Yel Air Hose Connection FinishPro 390 Exhaust
More informationTrouble Shooting Guide for Hubbell Systems
Trouble Shooting Guide for Hubbell Systems NOTE: Hubbell Special Products discontinued operations in 2008, so there is a very limited number of repair parts available for motor repair. In some ways, this
More informationUSER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment
USER MANUAL FOR 2000 WATTS POWER INVERTER Your 2000 watts power inverter converts 12-volt vehicle battery power into 230 volts of AC power. You can use the inverter in your vehicle to operate many types
More informationGET GROUNDED. Renewable Energy System Grounding Basics
GET GROUNDED Renewable Energy System ing Basics by Christopher Freitas ASK TEN RENEWABLE ENERGY INSTALLERS ABOUT SYSTEM GROUNDING and you ll likely get ten different opinions as to what the National Electrical
More informationDoor panel removal F07 5 GT
Things needed Decent plastic trim removal tools Torx 30 Spare door clips 07147145753 I got away with a set of 5 but if I did it again I d be cautious and get 10. From prior experience if they are damaged
More informationA/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES
Article Text ARTICLE BEGINNING 1993 AIR CONDITIONING & HEAT A/C General Diagnostic Procedures Diagnosis is an important first step in A/C system servicing. To save time and effort, systems should be carefully
More informationGay E. Canough. OFF-GRID Design. Dr. Gay E. Canough, Master trainer. Living Off the Grid
OFF-GRID Design Dr. Gay E. Canough, Master trainer 1 Understand the Customer s load 2 Load sizing Gay E. Canough AC Appliance watts amps how many of these? number of hours it is used per day equals watt-hr/
More informationBuilding Operator Certification Level I
Building Operator Certification Level I A Partnership of the CUNY Institute for Urban Systems Building Performance Lab, the CUNY School of Professional Studies, and the New York State Energy Research &
More informationTONY S TECH REPORT. Basic Training
TONY S TECH REPORT (Great Articles! Collect Them All! Trade them with your friends!) Basic Training OK YOU MAGGOTS!! Line up, shut up, and listen good. I don t want any of you gettin killed because you
More informationLab 6: Wind Turbine Generators
Lab 6: Wind Turbine Generators Name: Pre Lab Tip speed ratio: Tip speed ratio (TSR) is defined as: Ω, where Ω=angular velocity of wind, and R=radius of rotor (blade length). If the rotational speed of
More informationCSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:
CSDA Best Practice Title: Hi-Cycle Concrete Cutting Equipment Issue No: CSDA-BP-010 : Oct 1, 2010 Revised : Introduction Hi-cycle/high frequency concrete cutting equipment has become more prevalent in
More informationElectronic Paint- Thickness Gauges What They Are, and Why You Need Them
By Kevin Farrell Electronic Paint- Thickness Gauges What They Are, and Why You Need Them Measuring the paint in microns. The reading of 125 microns is a fairly normal factory reading. This shows that the
More informationMatrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING
Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.
More information5300 Series Installation Guidelines
1-800-443-4859 5300 Series Installation Guidelines WARNING: RISK OF ELECTRICAL SHOCK OR BURNS. THIS CONVERTER ASSEMBLY SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN OR CERTIFIED RV TECHNICIAN. IMPROPER
More informationCritical Home Power. Economical Manual start Whole House AC Power For Amateurs. Hugh Maguire N1QGE
Critical Home Power Economical Manual start Whole House AC Power For Amateurs Hugh Maguire N1QGE Goal of presentation Show how one amateur supplied all the critical loads in the home with minimal temporary
More informationFRACTIONAL HORSEPOWER MOTORS & ACCESSORIES
TABLE OF CONTENTS Motor Information Guide Definitions And Abbreviations... page 2 Motor Identification Without A Nameplate What To Look For... page 3 Direct Drive Blower Motors: Two Speed... page 4 Three
More informationQ&A FOR Webinar on Electrical Basics & Boiler Wiring
Q&A FOR Webinar on Electrical Basics & Boiler Wiring 4-20-16 Q: Is a dual fuel burner flame guard system more complicated than the one you showed us today? A: Not really. If the boiler is equipped for
More information24% higher part-load efficiency saves running costs.
Danfoss Scroll Compressors SH485 The family is growing Get more for less with the big blue The unique design of the SH485 offers a compact and innovative 40-ton capacity scroll in the size of a 30-ton
More informationA direct current (DC) circuit. Alternating Current (AC) Direct Current DC. AC current. L 27 Electricity and Magnetism [4]
L 27 Electricity and Magnetism [4] A direct current (DC) circuit simple electrical circuits direct current DC Alternating current (AC) vs direct current (DC) electric power distribution household electricity
More informationThe Benefits of AC Hard Starts
The Right Choice SEALED UNIT PARTS CO., INC. PO Box 21, 2230 Landmark Place Allenwood, NJ 08720 USA 800-333-9125 www.supco.com The Benefits of AC Hard Starts From the Pioneer of Hard Start Technology THE
More informationPetrochemical processing Ship Yards Oil Fields Irrigation
TITAN is your solution When you have demanding three phase power requirements and when need a phase conversion system that is up to the challenge you need the TITAN. Whether you re powering a single Machine
More informationUPPCO SERVICE MANUAL
Revised 01/2015 Section 6 ELECTRIC SERVICE - GENERAL Page 1 of 10 Section 6 Electric Service - General 6-1 Number of Services and Voltages / Meter... 2 6-2 Energy Conversion Factors... 7 6-3 Lightning
More informationVoltPro VP4 Automatic Voltage Regulator
VoltPro VP4 Automatic Voltage Regulator The VoltPro VP4 Automatic Voltage Regulator is an affordable generator voltage regulator that is designed for the consumer market and can replace many popular voltage
More informationPortable Oil Free Silent Series Compressor Operating Instructions
Portable Oil Free Silent Series Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 www.eaglecompressor.com
More informationSteeda Sport Mustang Lowering Springs (2005+) - Installation Instructions
Steeda Sport Mustang Lowering Springs (2005+) - Installation Instructions The below installation instructions work for the following products: Steeda Sport Mustang Lowering Springs (2005+) Please read
More informationWiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.
1 10/2014 REV 7 !!Attention!! Before performing diagnostics: Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents. Check for Fault Codes using the
More informationContents. Preparing the motor Winding the rotating secondary Winding the primary... 8
120732-130389 Propeller Clock Construction Notes Revision E, December 2, 2013 Contents Preparing the motor... 2 Winding the rotating secondary... 5 Winding the primary... 8 UltiProp Clock (Elektor Dec.
More informationInstallation and Construction Notes for EVSE4
Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process
More informationALL AMERICAN BILLET. Front Drive System - Small Block Ford Installation Instructions
ALL AMERICAN BILLET Front Drive System - Small Block Ford Installation Instructions Small Block Ford with AC & PS All American Billet Store (800) 764-0926 www.allamericanbilletstore.com Items needed for
More informationElectronic Refrigerator Diagnostics
Electronic Refrigerator Diagnostics IMPORTANT SAFETY NOTICE The information in this presentation is intended for use by individuals possessing adequate backgrounds of electrical, electronic, & mechanical
More informationForeword and disclaimer:
Installation guide for the ADA Depot MDRT transformer. Foreword and disclaimer: Thank you for purchasing this Machinator transformer kit. These kit suites the MP-1,/ MB-1. This kit also solves the famous
More informationTechnical Information and Diagnostic Guide
Technical Information and Diagnostic Guide This guide will assist you in becoming more familiar with the working components of the NITE System and the proper steps and procedures to completely diagnose
More informationService Entrance Methods
Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility
More informationElectrical Safety Part I
Electrical Safety Part I Mains voltage electricity is extremely dangerous. There is a significant risk of death through electrocution if mains voltage electricity is allowed to pass through the body. There
More informationATLAS Wheel Balancer Electrical Flow Chart
ATLAS Wheel Balancer Electrical Flow Chart WARNING: Leave all work to trained and licensed electricians. Attempting repairs yourself is extremely dangerous, with the potential for serious injury and even
More informationUnderstanding the Modern Automotive Air Conditioning System. Trainer: Grant Hand
Understanding the Modern Automotive Air Conditioning System Trainer: Grant Hand AUTOMOTIVE TRAINING SOLUTIONS PTY LTD Training for the future... Automotive Training Solutions IMPORTANT NOTE Copyright The
More informationVOLTAGE SAGS; A LITTLE STORAGE CAN GO A LONG WAY
WHITE PAPER VOLTAGE SAGS; A LITTLE STORAGE CAN GO A LONG WAY I. Utility power in the U.S. is very reliable; we count on it to be there, expect it to be there, and it usually is. Barring natural disasters
More informationA/C Generator Systems
A/C Generator Systems What is the function of the charging system? Provide power for all electrical loads Recharge the starting battery What happens if the charging systems puts out too much power? Voltage
More informationTempest Tech-Tip 0613
June 2013 Tempest Tech-Tip 0613 Alaska Cold Starts Background What really happens in an oil filter during a cold start? First, by cold start, we re talking about starting an engine in temperatures below
More informationDODGE OFF ROAD T-STYLE STEERING KIT INSTALLATION INSTRUCTIONS
Dodge Off Road, LLC Specializing in Dodge Ram Solid-Axle 4x4 Suspension and Steering for Off Road Applications 855.9009.DOR sales@dodgeoffroad.com dodgeoffroad.com DODGE OFF ROAD T-STYLE STEERING KIT INSTALLATION
More informationMODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE
MODEL 600A 6 VOLT BATTERY CHARGER ASSOCIATE IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This manual contains important safety and operating instructions for the battery charger you have purchased.
More informationNote: Do NOT mix LED and incandescent lamps in the same circuit!
Light Up Your Modified Car Some Hot Rod lights are hard to see. Your teardrop lights may look cool, but the 5W incandescent lamp that came with it just doesn t light up bright enough to show others you
More informationCommon Bus and Line Regeneration
Common Bus and Line Regeneration Addressing VFD applications when Regenerative Energy is Present Steve Petersen, Drives Technical Training Yaskawa America, Inc. Variable frequency drives (VFDs) are implemented
More informationDash removal for 1968 Chevelles
Dash removal for 1968 Chevelles This is the procedure I used when I removed the dash from my car. It s a column shift, automatic trans, A/C car with tach and gauges. 1. Disconnect the battery. 2. Remove
More informationMotor capacitors. Run Capacitors. Start Capacitors. Service notes. Two types 1. Run Capacitors 2. Start Capacitors
Motor capacitors Two types 1. Run Capacitors 2. Start Capacitors Run Capacitors These capacitors are used in capacitor run motors in pressure pumps, washing machine, dryers, dishwashers etc. with capacitor
More informationSingle Phase Induction Motor. Dr. Sanjay Jain Department Of EE/EX
Single Phase Induction Motor Dr. Sanjay Jain Department Of EE/EX Application :- The single-phase induction machine is the most frequently used motor for refrigerators, washing machines, clocks, drills,
More informationPRODUCT CATALOG. RSD (Refrigeration Supplies Distributor) / Spokane 212 E. Pacific Spokane (509) ruud.com. Rely on Ruud.
HVAC PRODUCT CATALOG RSD (Refrigeration Supplies Distributor) / Spokane 212 E. Pacific Spokane 99202 (509) 838-0593 ruud.com Rely on Ruud. Package Heat Pump B (2-4 Ton)... 1 - PACKAGE HEAT PUMP Ruud Achiever
More informationP5RF Series Rev "A" Single Packaged Air Conditioner Single Phase
TECHNICAL SPECIFICATIONS P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners
More informationREAD AND SAVE THESE INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS Part #469003 Model Vektor -H Installation Operation and Maintenance Manual for Vektor-H Laboratory Exhaust System Receiving Greenheck model Vektor-H fans are thoroughly
More informationESS INSTALL. The donor car /6 Cosmos Black/Sand UUC Short Shifter Brembo cross drilled rotors Phillips Nav System 16:9
ESS INSTALL The donor car.. 1997 540/6 Cosmos Black/Sand UUC Short Shifter Brembo cross drilled rotors Phillips Nav System 16:9 The install went in several stages. Disconnect the battery Stage 1 Remove
More informationPower Management for professionals! HC-CARGO Battery Isolators. Your Expert in Parts. Your Expert in Parts. Overview HC-CARGO Battery isolators
Power Management Power Management for professionals! A failed power supply or a failed converter is a failed system. The sensitivities of modern electronic equipment to variable input voltages, has made
More informationElectric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium
Electric Drive Vehicle Infrastructure Training Instructor s Manual National Alternative Fuels Training Consortium Part 4: : Service Panel to Receptacle Overview of Service Panel The role of the service
More informationSteve Schouten. Donna Densmore
March 12, 2013 2 Steve Schouten Donna Densmore 3 Mike Carter Justin Kale 4 Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality Issues Source: Emerson Industrial Automation
More informationEmerging Oil Free Technologies. Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc.
Emerging Oil Free Technologies Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc. rgood@danfoss.com 1 Agenda Chiller Overview Benefits of Oil Free Oil Free Compressors
More informationINSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information
INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -
More informationSingle Phase Induction Motors
Single Phase Induction Motors Prof. T. H. Panchal Asst. Professor Department of Electrical Engineering Institute of Technology Nirma University, Ahmedabad Introduction As the name suggests, these motors
More informationA1P OPERATING MANUAL
A1P OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty...
More informationIdle Free Systems, Inc. Reference Guide System Component Information
Idle Free Systems, Inc. Reference Guide System Component Information #68004 REV 3 #68004 REV 3 Idle Free Reference Sheets System Components & Trouble shooting Table of Contents RF # 101.0 102.0 103.0 104.0
More informationMotor Protection. Voltage Unbalance & Single-Phasing
For Summary of Suggestions to Protect Three-Phase Motors Against Single-Phasing see the end of this section, page 137. Historically, the causes of motor failure can be attributed to: Overloads 30% Contaminants
More informationINFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT
INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT This Information Sheet provides guidance on how to carry out User Checks, Formal Visual Inspections and combined Inspection and Tests on portable
More informationArtesis MCM Case Studies. March 2011
Artesis MCM Case Studies March 2011 Case 1 Automotive Company: Automobile Manufacturer A Equipment: Pump Stator Isolation Breakdown Decreasing current unbalance level Case 1 Automotive Company: Automobile
More informationSineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING
SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of
More informationVariable speed application guidelines
Variable speed application guidelines Frequency converter VLT 00 SCROLL COMPRESSORS REFRIGERATION AND AIR CONDITIONING www.danfoss.com Introduction The introduction of speed control for refrigeration
More informationAn unwritten rule says that when a. Cures for a sick spot welding machine. Figure 1. To test the secondary of the welding machine,
Figure 1 To test the secondary of the welding machine, the power should be turned off. With the electrodes open, the continuity between the top and bottom electrodes should be checked. Cures for a sick
More informationAUTO CHARGE D PUMP PLUS
INSTRUCTION MANUAL AUTO CHARGE D PUMP PLUS AUTOMATIC DUAL OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-9-DPP INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY:
More information6900-( )-( ) HIGH SPEED SANDWICH PRESS
SERVICE MANUAL 6900-( )-( ) HIGH SPEED SANDWICH PRESS CAUTION PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow
More informationTen Deadly Conditions to Check for in Your Boat's Electrical System - Part 2
Ten Deadly Conditions to Check for in Your Boat's Electrical System - Part 2 In the September newsletter, 1 through 5 of the ten deadly conditions were presented (link to previous article). Deadly conditions
More informationPiston Compressors. Volume range: l/min
Piston Compressors Volume range: 235 10900 l/min Intelligence, innovation, reliability variable modular system operationally reliable low speeds long operating life of valves low noise emission robust
More information