1 Building Operator Certification Level I A Partnership of the CUNY Institute for Urban Systems Building Performance Lab, the CUNY School of Professional Studies, and the New York State Energy Research & Development Authority

2 Building Operator Certification Level I (BOCI) Building Systems: Electrical CUNY School of Professional Studies CUNY Building Performance Lab The BOC Power Basics: Lesson 1

3 Building Electrical Systems Objectives Understand fundamentals of electricity Know fundamental electrical terminologies Apply basic electrical theory when overseeing electrical maintenance and testing

4 Agenda Electricity Fundamentals Electrical Circuits & Measurement Building Electrical System

5 Section 1 Fundamentals Magnetism and Induction Motors and Generators Electrical Terms and Ohm s Law

6 Electrical Fundamentals Video 1: Electricity and Circuits NUCLEUS - ELECTRON ELECTRON ORBIT + PROTON NEUTRON BASIC ATOMIC STRUCTURE ELECTRON FLOW - + CONCEPTUAL VIEW OF A CONDUCTOR WITH APPLIED VOLTAGE

7 Magnetism Permanent Temporary Electromagnetic Fields _ +

8 Magnetism & Induction Video 2: Electro-Magnetic Induction

9 Electrical Induction Video 3: How a Solenoid Works A N S S N + G - B

10 Video 4: Motors & Generators 5c

11 AC Cycles and Phases One Cycle of single phase AC shown as a sine wave One Cycle of three phase AC shown as a sine wave Phase 3 Phase

12 Electrical Induction Video 5: How Electric Motors Work 5b

13 Electrical Induction: Transformers Raise and lower voltages Have primary and secondary coils Provide electrical Isolation

14 Electrical Terms

15 Ohm s Law Ohm's Law states that one volt pushes one amp through one ohm of resistance P or W = Power (expressed in watts) I or A = Amperage (expressed in amps) V or E = Voltage (expressed in volts) R = Resistance (expressed in ohms) E = I x R {or V = A x Ohms} P= E x I {or W= V x A} E P I R E I

16 Electrical Laws & Equations (Amps is) Current = Voltage Resistance Current = 120 Volts = 12 Amps 10 Ohms (Watts is) Power = Voltage x Current Power = 120 Volts x 5 Amps Power = 60 Watts

17 Power Wheel 2 E R x I I 2 R x I E x P R P E R E R P I 2 I P P x R E I 2 E P

18 Section 2 Electrical Circuits Measuring Electrical Circuits Electrical Safety Electrical Circuit Protection

19 Circuits

20 Open and Closed Circuits L1 PB1 PB2 PB1 on rung 1 is open, the circuit is open, the load is de-energized PB2 on rung 2 is closed, the circuit closed, the load is energized L1 L2 L2 Circuits consist of a voltage source, a pathway made of conductors, and a load or loads An open circuit has a break in it and is deenergized A closed circuit has no break and is energized.

21 Series Circuit: There is only one pathway for current to flow S1 Switch is controlling all the lights in the circuit The two Push Buttons (PB) are in series with the light L1 PB1 PB2 R L2 When either one is open, what happens?

22 Parallel Circuits: have at least two pathways for current flow. L1 L2 S1 1 L1 2 L2 3 L3 4 L4 This Parallel circuit has four separate pathways for current flow.

23 Measuring Electricity Do not work on any electric equipment unless you are trained and qualified to do electrical work. Treat all circuits as if they were live. De-energize any circuit before working on it. Read and learn all safety procedures regarding the meter you use

24 Measuring Voltage Volt measurements are taken in parallel Voltage drop is voltage used at a load Amperage measurements use clamp-on or line splitter attachments L1 L2 Connect the volt meter in parallel with the component being tested.

25 Measuring Current - Amps Clamp On Ammeter to measure current

26 Measuring Volts & Amps OPEN CONTACTS CLOSED CONTACTS V AMPS = 0 VOLTS = 120 AMPS = 10 RESISTANCE = 0 VOLTS = 0 V V CLOSED CONTACTS PITTED & CORRODED AMPS = 10 RESISTANCE = 2.5 OHMS VOLTS = 25

27 Short Circuits A short circuit has a direct bypass around the load High amperage causes dangerous overheating Circuit protection should open to prevent damage Circuit Protection Fuses contain metal filaments that melt when they reach a specific temperature A circuit breaker opens at a specific temperature caused by a specific amperage

28 Troubleshooting Fuses A good fuse has continuity nearly zero ohms A blown fuse has no continuity infinite resistance Find the cause of the blown fuse Replace a fuse by putting it into the load side first, then the line side (Note: Never replace a fuse in an energized circuit)

29 Testing Fuses A good fast acting fuse will register nearly zero resistance A good slow acting fuse will register some resistance A bad, open fuse of either type will register infinite resistance

30 How Ground Circuits Work Ground wires are part of the safety circuit.

31 Section 3 Electrical Maintenance Exercise: Testing Transformers Voltage Irregularities

32 Overheating in Breaker Panels Overloaded circuits are HOT Loose connections are HOT Corroded contacts are HOT Scan all Breaker Panels once a year Exercise Breakers / Switches once a year

33 No Voltage to a Circuit Check circuit breaker or circuit fuses Find cause of blown fuse or tripped breaker If no breaker is tripped, check power into circuit breaker panel box Reset tripped breaker, replace fuses

34 Troubleshooting Circuit Breakers A good circuit breaker is in the On position A tripped circuit breaker is in the Middle or Off position Find the cause of the tripped breaker Breakers must be correctly labeled Trace circuits using circuit tracers

35 Testing a Transformer with Ohmmeter Video 2: How Transformers Work 4 min "OL"; NO CONTINUITY H1 H2 "OL"; NO CONTINUITY X1 X3 X2 X4 CORRECT, OR GOOD OHM METER MEASUREMENTS Multi-Meter is set to measure Resistance "OL"; NO CONTINUITY

36 Testing a Transformer with Ohmmeter BAD OHM METER MEASUREMENTS "OL"; NO CONTINUITY H1 H2 X1 X3 X2 X4 "OL"; NO CONTINUITY

37 Voltage Irregularities Over- and under-voltages Disruptions Voltage surges- high Voltage dips - Low Spikes - High Electric noise Harmonic Voltage Variations Low voltage can cause operational [rpblems Increased amps can increase heat 5% Voltage loss maximum acceptable

38 Voltage and Phase Monitoring Check for phase loss Check for phase sequence reversal Check voltage quality monitors Maintain cooling equipment for power vault and panel boxes

39 Section 4 Building Electrical System Electric Safety

40 Building Electrical System Main Components of System Incoming Service Components Transformer Disconnect Switch Electric Meter Main Distribution Panel Circuit Breaker Panels ( 1 Phase & 3 Phase Power ) Loads in Building (HVAC, Motors, Lighting, etc.

41 Building Electrical Systems

42 Building Electrical System Main Distribution Panel Cubicles for each load Disconnect Switch in each cubicle Electric Bus Bar To each Disconnect Disconnect Switches Each to a feeder circuit

43 Transformers Purpose of Transformers - Raise or lower voltage for use Transformers are used in these locations: - Outside Building: Service to building - Power Vault: Reduce Voltage - Distribution in building - Control Transformers in equipment

44 Service Transformer / Distribution Transformer Transformer Dry Type Single Phase Step-down: 480/240V or 240/120V Rated Capacity: 15KVA Limited Output: 15,000 Volt-Amps Control Transformer Supplies the control voltage inside the equipment

45 Building Electrical System FEEDER BRANCH M LARGE MOTORS TO LARGE LOADS BRANCH BRANCH BRANCH CKT MAIN DISTRIBUTION PANEL 480V 120/208V L BRANCH HIGH VOLTAGE PANEL FEEDER LOW VOLTAGE PANEL

46 Building Electrical System Distribution in the Building Breaker Panel High Voltage 208V / 270V / 480V Three phase or single phase Large Motors Breaker Panel Low Voltage 110V / 120V Single phase only Small loads: lights, plug loads, small equipment

47 Voltage Phases Single phase low voltage, single phase high voltage, three phase voltage.

48 Building Electrical System Breaker Panel Low Voltage Lighting Plug Loads Low Voltage Loads

49 Three Phase Panel PANEL BUS BARS W/WIRE LUGS FOR FEEDER CONNECTION CIRCUIT BREAKERS A B C NEUTRAL CONNECTION BAR GROUND CONNECTION BAR

50 Circuit Protection A circuit breaker opens at a specific temperature caused by a specific amperage. Fuses contain metal filaments that melt when they reach a specific temperature.

51 Safety Lock-outs and Tag-outs Work with a partner Let people know where you are working Use lock-outs / tag-outs De-energize circuit Test circuit first Never remove another person s lock or tag

52 Electrical Standards NEC- National Electrical Code NEMA- National Electrical Manufacturer s Association When to Call for Help ANY TIME YOU WANT TO! If no power into circuit breaker panel box, check fuses protecting the panel box. If fuses are good, call in an electrician Know where in the circuit to stop testing Use test equipment safely

53 Review and Class Reading Assignments (Weeks 1 and 2) What your reactions? Main learning points you gained from the first class? BOC 107: to review Power Basics (this week, Week 1) FEMP Section 9.12 (Ch. 9, Sec. 12, pages )

Full file at

Full file at CHAPTER 2 FUNDAMENTALS OF ELECTRICITY Job Assignment for This Chapter: You are on a service call and a customer does not understand the basic theory of electricity and thinks you are trying to sell parts

More information

ELECTRICAL. CDTA Technical Training Center

ELECTRICAL. CDTA Technical Training Center ELECTRICAL ATOMIC STRUCTURE Protons positive charge Electron negative charge Neutron - neutral Electricity is the movement of electrons from atom to atom ELECTRON FLOW CONDUCTOR - Materials which have

More information

Modern Auto Tech Study Guide Chapter 8 Pages Electricity & Electronics 37 Points. Automotive Service

Modern Auto Tech Study Guide Chapter 8 Pages Electricity & Electronics 37 Points. Automotive Service Modern Auto Tech Study Guide Chapter 8 Pages 97 110 Electricity & Electronics 37 Points Automotive Service 1. is the movement of electrons ( ) from atom to atom. Every vehicle system uses some type of

More information

Science Part B Chapter 4- Electrical Energy. Lesson 1-

Science Part B Chapter 4- Electrical Energy. Lesson 1- Science Part B Chapter 4- Electrical Energy Lesson 1- Most atoms have equal numbers of protons, which are positively charged, and electrons, which are negatively charged. These atoms have no charge; they

More information

How is lightning similar to getting an electric shock when you reach for a metal door knob?

How is lightning similar to getting an electric shock when you reach for a metal door knob? How is lightning similar to getting an electric shock when you reach for a metal door knob? Electricity Electric charges are from protons, which are positive (+) and electrons, which are negative (-).

More information

Student Exploration: Advanced Circuits

Student Exploration: Advanced Circuits Name: Date: Student Exploration: Advanced Circuits [Note to teachers and students: This Gizmo was designed as a follow-up to the Circuits Gizmo. We recommend doing that activity before trying this one.]

More information

Adapted from presentation developed by Scott Fausneaucht

Adapted from presentation developed by Scott Fausneaucht Adapted from presentation developed by Scott Fausneaucht Definition of Electricity Electrical Fundamentals Generation & Transmission Transformers Fuses & Circuit Breakers Motors Motor Controls Safety Not

More information

Electricity. Chapter 20

Electricity. Chapter 20 Electricity Chapter 20 Types of electric charge Protons + charge Electrons - charge SI unit of electric charge is the coulomb (C) Interactions between charges Like charges repel Opposite charges attract

More information

Electric Motor Controls BOMA Pre-Quiz

Electric Motor Controls BOMA Pre-Quiz Electric Motor Controls BOMA Pre-Quiz Name: 1. How does a U.P.S. (uninterruptable power supply) work? A. AC rectified to DC batteries then inverted to AC B. Batteries generate DC power C. Generator, batteries,

More information

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety. Using Electricity Summary Notes Section Content 1. From the Wall Socket Household appliances. Earth wire and safety. 2. Alternating and Direct Battery and transformer. Current Circuit diagrams. Current

More information

Electrical Energy and Power Ratings

Electrical Energy and Power Ratings Section 1 - From the Wall Socket Electrical Energy and ower Ratings Batteries and the mains are sources of electrical energy. Electrical appliances can then convert this into other forms of energy. e.g.

More information

UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1. UNIT 2 ELECTRICAL CIRCUITS...49 Introduction...49

UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1. UNIT 2 ELECTRICAL CIRCUITS...49 Introduction...49 UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1 PART A ELECTRICIAN S MATH...1 Introduction...1 1.1 Whole Numbers...1 1.2 Decimal...1 1.3 Fractions...1 1.4 Percentages...2 1.5

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

Parts of an atom. Protons (P + ) Electrons (e - ) Neutrons. Have a positive electric charge. Have a negative electric charge

Parts of an atom. Protons (P + ) Electrons (e - ) Neutrons. Have a positive electric charge. Have a negative electric charge Electricity Parts of an atom Protons (P + ) Have a positive electric charge Electrons (e - ) Have a negative electric charge Neutrons Are neutral Have no charge Electric Charge In most atoms, the charges

More information

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE Duty B: Power Distribution (600V and below) B-03: Troubleshoot 480V System Issued 06/01/98 Task Preview Troubleshoot 480V System The 480V distribution

More information

Understanding Electricity and Electrical Safety Teacher s Guide

Understanding Electricity and Electrical Safety Teacher s Guide Understanding Electricity and Electrical Safety Teacher s Guide Note to Instructor: The activities and experiments in this booklet build on each other to develop a student s understanding of electricity

More information

Electrical Equipment and Safety: Operation, Control, Maintenance and Troubleshooting

Electrical Equipment and Safety: Operation, Control, Maintenance and Troubleshooting Electrical Equipment and Safety: Operation, Control, Maintenance and Troubleshooting Page 1 of 6 Why Attend This course covers the theoretical and practical operation of common electrical equipment and

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

Electricity Unit Review

Electricity Unit Review Science 9 Electricity Unit Review Name: General Definitions: Neutral Object Charge Separation Electrical Discharge Electric Current Amperes (amps) Voltage (volts) Voltmeter Ammeters Galvanometer Multimeter

More information

FACT SHEET Standard: Electrical Safety

FACT SHEET Standard: Electrical Safety What is a Ground Fault Circuit Interrupter? FACT SHEET The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc. Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution

More information

Service Manual for Battery Control Center

Service Manual for Battery Control Center Service Manual for Battery Control Center P/N 82 E0071 00 (Ref. 81 1317) June, 1999 Battery Control Box Operation Charging Circuit This function charges the coach battery from the engine alternator while

More information

Electrical Safety. Introduction

Electrical Safety. Introduction Electrical Safety Introduction Electrical hazards 300 electrocutions every year in the U.S. Leading cause is insufficient training ALL were preventable What is Electricity? How Electricity Works Created

More information

Electrical Equipment and Terminology

Electrical Equipment and Terminology Youth Explore Trades Skills Description Understanding the language of the electrical trade and knowing what electrical equipment is named and its purpose are very important. Anyone who is exposed to a

More information

ELECTRIC POWER AND HOUSEHOLD CIRCUITS

ELECTRIC POWER AND HOUSEHOLD CIRCUITS ELECTRIC POWER AND HOUSEHOLD CIRCUITS HEATING EFFECT OF CURRENT Heating effect of electricity is one of the widely-used effects in the world. When electric current is passed through a conductor, it generates

More information

Chapter: Electricity

Chapter: Electricity Chapter 13 Table of Contents Chapter: Electricity Section 1: Electric Charge Section 2: Electric Current Section 3: Electrical Energy 1 Electric Charge Positive and Negative Charge Atoms contain particles

More information

Electrical Systems. Introduction

Electrical Systems. Introduction Electrical Systems Figure 1. Major Components of the Car s Electrical System Introduction Electricity is used in nearly all systems of the automobile (Figure 1). It is much easier to understand what electricity

More information

ECET Distribution System Protection. Overcurrent Protection

ECET Distribution System Protection. Overcurrent Protection ECET 4520 Industrial Distribution Systems, Illumination, and the NEC Distribution System Protection Overcurrent Protection One of the most important aspects of distribution system design is system protection.

More information

HVACR Electrical Systems

HVACR Electrical Systems HVACR Electrical Systems to The following HVAC Excellence competencies (rev. 2007) are covered in this publication. Only the covered compentencies are listed. The first column identifies the competency

More information

2017 NEC Electrical Review RV

2017 NEC Electrical Review RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS Electrical/Electronic Systems UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS LESSON 3: TEST electrical circuits I. Types of electrical circuit tests and electrical faults A. Different types of electrical

More information

FUN! Protected Under 18 U.S.C. 707

FUN! Protected Under 18 U.S.C. 707 FUN! Protected Under 18 U.S.C. 707 DC I Lesson Objectives: 1. What is Electricity? 2. Discover the Electron 3. Learn about Conductors and Insulators 4. Learn about Voltage and Current 5. Learn the difference

More information

Customer Requirements Downtown Secondary Network Service

Customer Requirements Downtown Secondary Network Service Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard

More information

ELECTRICAL. 60 Minutes

ELECTRICAL. 60 Minutes ELECTRICAL 60 Minutes AGENDA Electrical definitions Electrical shocks, burns and secondary injuries Electrical hazards in the workplace Safety devices and prevention steps Do s and Don ts INTRODUCTORY

More information

Chapter 1 Electrical Theory...1

Chapter 1 Electrical Theory...1 Electrical Formulas with Sample Calculations Table of Contents Chapter 1 Electrical Theory...1 Unit 1 Electrician s Math and Basic Electrical Formulas...3 Part A Electrician s Math...3 1 1 Fractions...3

More information

Overcurrent protection

Overcurrent protection Overcurrent protection This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,

More information

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrical Safety Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock) Electrical shock

More information

TABLE OF CONTENTS CHAPTER 1 ELECTRICAL THEORY About This Textbook...xi. Passing Your Exam...xiv. How to Use the National Electrical Code...

TABLE OF CONTENTS CHAPTER 1 ELECTRICAL THEORY About This Textbook...xi. Passing Your Exam...xiv. How to Use the National Electrical Code... TABLE OF CONTENTS About This Textbook...xi Passing Your Exam...xiv How to Use the National Electrical Code... 1 CHAPTER 1 ELECTRICAL THEORY... 7 Unit 1 Electrician s Math and Basic Electrical Formulas...

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

TABLE OF CONTENTS. About the Mike Holt Enterprises Team... xviii CHAPTER 1 ELECTRICAL THEORY... 1

TABLE OF CONTENTS. About the Mike Holt Enterprises Team... xviii CHAPTER 1 ELECTRICAL THEORY... 1 TABLE OF CONTENTS Introduction...xv About the Mike Holt Enterprises Team... xviii CHAPTER 1 ELECTRICAL THEORY... 1 Unit 1 Electrician s Math and Basic Electrical Formulas... 1 Part A Electrician s Math...

More information

Exercise 1-1. Lockout/Tagout Procedure EXERCISE OBJECTIVE DISCUSSION. Become familiar with the Industrial Controls Training System.

Exercise 1-1. Lockout/Tagout Procedure EXERCISE OBJECTIVE DISCUSSION. Become familiar with the Industrial Controls Training System. Exercise 1-1 Lockout/Tagout Procedure EXERCISE OBJECTIVE Become familiar with the Industrial Controls Training System. Understand and perform proper lockout/tagout procedures during industrial servicing

More information

Unit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace

Unit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace Assessment Requirements Unit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace Content: Basic electrical principles a. Explain the direction of current flow

More information

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit. CHAPTER 17 4 Electric Circuits SECTION Introduction to Electricity BEFORE YOU READ After you read this section, you should be able to answer these questions: What are the three main parts of a circuit?

More information

Miniature circuit breaker Application guide

Miniature circuit breaker Application guide Miniature circuit breaker Application guide Miniature Miniature circuit circuit breakers breakers Application S200 guide Introduction The circuit breaker plays an important role in providing over-current

More information

Lesson 2: Electrical Safety Ladders can become electrified if they come into contact with electric wires. Don't raise a ladder close to electric

Lesson 2: Electrical Safety Ladders can become electrified if they come into contact with electric wires. Don't raise a ladder close to electric Lesson 2: Electrical Safety Ladders can become electrified if they come into contact with electric wires. Don't raise a ladder close to electric lines. Never touch hanging or broken wires. Don't trim trees

More information

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING TROUBLESHOOTING for the 5 BUTTON 3109228.001 COMFORT CONTROL CENTER SYSTEM INTRODUCTION The Comfort Control Center control system can be used to operate the following Duo-Therm Units: Roof Top Air Conditioners

More information

English for Electrical Engineers

English for Electrical Engineers University of Kurdistan Department of Electrical & Computer Engineering English for Electrical Engineers H. Bevrani October, 2017 1 Contents Unit 1. Current, voltage and resistance... 3 Unit 2. Electrical

More information

Table of Contents. CHAPTER 1 ElECTRiCAl THEoRY Mike Holt enterprises, inc neC.Code ( )

Table of Contents. CHAPTER 1 ElECTRiCAl THEoRY Mike Holt enterprises, inc neC.Code ( ) CHAPTER 1 ElECTRiCAl THEoRY... 1 UniT 1 electrician s MaTH and BasiC electrical formulas... 3 Introduction to Unit 1... 3 Part A Electrician s Math... 3 Introduction... 3 1.1 Whole Numbers... 3 1.2 Decimals...

More information

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1 Webinar 1 Electrical 2 1 Webinar Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock)

More information

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter. RINV1200P REINV1200P RINV2200P REINV2200P

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter.  RINV1200P REINV1200P RINV2200P REINV2200P POWERSOURCEPURE Pure Sine Wave Inverter RINV1200P REINV1200P RINV2200P REINV2200P INSTRUCTIONS Retain these instructions for future reference www.ringautomotive.co.uk OVERVIEW The Ring Pure Sine Wave (PSW)

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Why is the Breaker Tripping?

Why is the Breaker Tripping? Why is the Breaker Tripping? Breakers are designed to trip anytime the circuit draws a current above the rating for a period of time. The time the breaker takes to trip is a function of how high the circuit

More information

Lab # 4 Parallel Circuits

Lab # 4 Parallel Circuits Lab # 4 Parallel Circuits Name(s) Obtain an Electro-Trainer and wire it exactly as shown (Be sure to use the 100 ohm resistor) 1) Record the volt drop and current flow for the Switch, the Resistor and

More information

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of

More information

Pretest Module 24 Three-phase Service Entrance

Pretest Module 24 Three-phase Service Entrance Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?

More information

1012-Electrical Diagrams

1012-Electrical Diagrams Term Absolute Pressure 1012-Electrical Diagrams Definition Total or true pressure. Gauge pressure plus atmospheric pressure. Absolute that includes the atmospheric pressure in its reading. This sensor

More information

Volume 2 Charts, Formulas, and Other Useful Information

Volume 2 Charts, Formulas, and Other Useful Information Volume 2 Charts, Formulas, and Other Useful Information Aluminum Conductor Conductor Terminations 61 Compact Aluminum (Conduit Fill Tables) 68-79 Ampacity Dwelling Services 48 1-phase Loads on a 3-phase

More information

ELECTRICITY AND HWH COPPER CONDUCTOR

ELECTRICITY AND HWH COPPER CONDUCTOR 1. PREFACE +BATTERY TERMINAL +BATTERY TERMINAL + + + + + + + + + + + + ELECTRICITY AND HWH In the first section of this school, we did an in-depth study of general hydraulics. In section four, we applied

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

LPT50BRD (8x11x3 Enclosure)

LPT50BRD (8x11x3 Enclosure) LPT50BRD (8x11x3 Enclosure) TROUBLESHOOTING AND REPAIR MANUAL ALL REPAIRS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN The LPT50BRD is a field repairable switch. Warranty covers defective parts only.

More information

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater. 0 EDITION AIM MANUAL SUBMERSIBLE MORS APPLICATION INSTALLATION 60 Hz, Single-Phase and Three-Phase Motors franklinwater.com All Motors System Troubleshooting Motor Does Not Start A. No power or incorrect

More information

A6Z OPERATING MANUAL

A6Z OPERATING MANUAL A6Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty.p.

More information

INSTALL CIRCUIT PROTECTIVE DEVICES

INSTALL CIRCUIT PROTECTIVE DEVICES SUBCOURSE EN5146 EDITION B US ARMY ENGINEER CENTER AND SCHOOL INSTALL CIRCUIT PROTECTIVE DEVICES INSTALL CIRCUIT PROTECTIVE DEVICES Subcourse Number EN5146 EDITION B United States Army Engineer School

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element Fusing Equipment Kearney Fuse Links Electrical Apparatus 327-40 general Cooper Power Systems Kearney fuse links can be applied to a variety of applications requiring overcurrent protection of distribution

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Electrical Service & Diagnosis. ATASA 5 th. ATASA 5 TH Study Guide Chapter 16 Pages Electrical Service & Diagnosis 70 Points

Electrical Service & Diagnosis. ATASA 5 th. ATASA 5 TH Study Guide Chapter 16 Pages Electrical Service & Diagnosis 70 Points ATASA 5 TH Study Guide Chapter 16 Pages 457 500 70 Points Please Read the Summary 1. All Electrical problems can be categorized into one of three categories: Open Consumer Opens Shorts Open Conductive

More information

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS? ARM V FDBK ENSURE MOTOR IS T ROTATING DURING POWER UP This fault can only happen in the first 3 seconds after power up. The processor looks at the armature voltage. The voltage needs to be near 0. Possible

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

Basics of Control Components

Basics of Control Components Basics of Control Components Table of Contents Introduction...2 Electrical Symbols...6 Line Diagrams...16 Overload Protection...22 Overload Relays...26 Manual Control...35 Magnetic Contactors and Starters...41

More information

Farr High School NATIONAL 4 PHYSICS. Unit 1 Electricity and Energy. Revision Notes

Farr High School NATIONAL 4 PHYSICS. Unit 1 Electricity and Energy. Revision Notes Farr High School NATIONAL 4 PHYSICS Unit 1 Electricity and Energy Revision Notes Content Practical electrical and electronic circuits - Measurement of current, voltage and resistance using appropriate

More information

Transmission & Distribution Glossary of Electrical Terms

Transmission & Distribution Glossary of Electrical Terms Transmission & Distribution Glossary of Electrical s Breaker Panel Bushing Circuit Circuit Breaker Conductor Conduit Consumption Current Distribution Electricity (Static vs. Current) Electron Feeder The

More information

Introduction to Electricity & Electrical Current

Introduction to Electricity & Electrical Current Introduction to Electricity & Electrical Current Physical Science Georgia Performance Standards: SPS10a. Investigate static electricity in terms of friction, induction, and conduction. SPS10b. Explain

More information

Questions Section: Do you have questions that aren't covered? Please contact us!

Questions Section: Do you have questions that aren't covered? Please contact us! Questions Section: 1. What are the screw terminals on the back of my XP600 for? 2. How do I hook up a remote turn-on switch for my XP250 / XP600 / XP1100/ MX series inverter? 3. Can I sell power back to

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

A1P OPERATING MANUAL

A1P OPERATING MANUAL A1P OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty...

More information

BMF TROUBLESHOOTING GUIDE

BMF TROUBLESHOOTING GUIDE BMF TROUBLESHOOTING GUIDE This document contains troubleshooting guidelines for PEP's standard BMF filters with pumps. REFERENCE DOCUMENTS: W-X-0039 BMF Electrical Wiring Drawing WP0011 BMF Control Panel

More information

Motor Protection. Presented By. Scott Peele PE

Motor Protection. Presented By. Scott Peele PE Motor Protection Presented By Scott Peele PE Motor Protection Overload on the motor load Fuses Heater Magnetic relay Short Circuit on motor circuit Fuses Breakers Single Phasing Overload Protection NEC

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Table of Contents. CHAPTER 1 BASIC ELECTRICAL THEORY (Essential for Journeyman and Master s Licensing Exams)... 1

Table of Contents. CHAPTER 1 BASIC ELECTRICAL THEORY (Essential for Journeyman and Master s Licensing Exams)... 1 Introduction... x About This Textbook...xi Passing Your Exam...xiv How to Use the National Electrical Code... xviii About the Author...xxi About the Graphic Illustrator...xxii Mike Holt Enterprises Team...

More information

L E A R N I N G O U T C O M E S

L E A R N I N G O U T C O M E S L E A R N I N G O U T C O M E S What is charge? How does a charge form? Electricity What is an electric current? Y E A R 1 0 C H A P T E R 1 2 What are conductors, insulators and semiconductors? How does

More information

TRANSMISSION SYSTEMS

TRANSMISSION SYSTEMS TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric

More information

General safety and installation information.

General safety and installation information. Read these instructions before connecting and using your PowerBright Pure Sine Power Inverters. Failure in observing this warning may result in injury to persons and damage to equipment. General safety

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

Circuits. What are circuits?

Circuits. What are circuits? Circuits Circuits What are circuits? A closed loop made of a conducting substance that allows electrons to flow from the negative terminal to the positive terminal Parts of a Circuit 1 Power Supply Provides

More information

A3Z OPERATING MANUAL

A3Z OPERATING MANUAL A3Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty...

More information

Electrical Tech Note 105 Agricultural Engineering Department Michigan State University

Electrical Tech Note 105 Agricultural Engineering Department Michigan State University Electrical Tech Note 105 Agricultural Engineering Department Michigan State University Journey Exam Study Guide and Sample Questions 1 Based on the 2002 NEC, Part 8 of PA 230, and the 2003 MRC The Journey

More information

New Section: Circuits & Machines. Warm Up: 1.) How do we use electricity every day? 2.) What do you think of when you hear the word "current?

New Section: Circuits & Machines. Warm Up: 1.) How do we use electricity every day? 2.) What do you think of when you hear the word current? New Section: Circuits & Machines. Warm Up: 1.) How do we use electricity every day? lights, computers, electronics, tvs, microwaves, etc... new, flowing...? 2.) What do you think of when you hear the word

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Pump Installation and Service Manual HRS Hydromatic Retractable System

Pump Installation and Service Manual HRS Hydromatic Retractable System Pump Installation and Service Manual HRS Hydromatic Retractable System NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION 100 KVA AND LARGER (CONCRETE PADS ONLY) 27.05-01 CABLE AND CONDUIT ENTRANCE SINGLE-PHASE PAD-MOUNTED TRANSFORMER INSTALLATION

More information

Electrical Safety. Recognizing & Controlling Hazards

Electrical Safety. Recognizing & Controlling Hazards Electrical Safety Recognizing & Controlling Hazards Introduction Healthcare facilities, including hospitals, physician offices, laboratoratories, dental offices and beyond are vulnerable to a variety of

More information

Design Standards NEMA

Design Standards NEMA Design Standards Although several organizations are involved in establishing standards for the design, construction, and application of motor control centers, the primary standards are established by UL,

More information

A Special Note To Our Customers

A Special Note To Our Customers A Special Note To Our Customers Here s a valuable handbook that you can use right now. This particular reference is taken from one of the video programs in our training series Electrical & Motor Controls

More information

Electrical Tech Note 106

Electrical Tech Note 106 Electrical Tech Note 106 Biosystems & Agricultural Engineering Department Michigan State University Master Exam Study Guide and Sample Questions 1 Based on the 2014 NEC, Part 8 of PA 230, PA 407, and the

More information