Certificate of Compliance
|
|
- Osborne Blake
- 6 years ago
- Views:
Transcription
1 Certificate of Compliance Certificate: Master Contract: Project: Date Issued: Issued to: Bel Fuse Inc. 206 Van Vorst St Jersey City, New Jersey USA Attention: Editha S. Vergara The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Juan-Carlos Olivera Juan-Carlos Olivera, MSc. PRODUCTS CLASS POWER SUPPLIES - Component Type (UL nd Ed) - Certified to U.S. Stds CLASS POWER SUPPLIES - Component Type (CSA nd Ed) Component type power supplies intended for use with Information Technology and Business Equipment, where the suitability of the combination is to be determined by CSA Group. Switching Power Supply, Models TCP , TCP3500-H048, TXP , TXP ; maybe followed by suffix G or SXXXG denoting non-safety critical options. Electrical Rating: Model TCP , TCP3500-H048, TXP TXP Input Output (DC) V A Hz V A/W / Vac, 3W+PE / Vac, 3W+PE / / A maximum, 3500 W maximum 36.5 A maximum, 4000 W maximum DQD 507 Rev Page 1
2 Certificate: Project: Master Contract: Date Issued: APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No , +Am.1:2011 +Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL Information Technology Equipment - Safety - Part 1: General Requirements CONDITIONS OF ACCEPTABILITY 1. This component has been judged on the basis of the required spacings in the Standard for Safety of Information Technology Equipment, CSA/UL , Second Edition, Sub-clause 2.10, which would cover the component itself if submitted for Listing. 2. The equipment has been evaluated for use in Pollution Degree 2 environment. 3. The Clearance values of the Power Supply Unit (PSU) have been evaluated for an altitude of 10,000ft (3048m), under IEC : 1992 Table A.2 (altitude correction factor is 1.15). 4. Touch Current Test was conducted at 305/520Vac, 60Hz and measured current for single unit was maximum 3.5mA. Earth connection is essential before connecting the power supply. 5. The Capacitance Discharge Test was conducted on the mains input, the requirements of UL /CSA were met. 6. The ground path from the appliance inlet to the PSU case meets protective bonding and has been evaluated at 80 A for TCP3500, TXP3500 models and 40 A for TXP Evaluated as Class I (earthed equipment). Reliable connection to Protective Earth shall be provided in the end use installation. 8. Evaluated for connection to AC power with a branch circuit protection rated max 40A for TCP3500 models and max. 20 A for TXP The PSU has been evaluated for a TN (Including TN-S and TN-C), IT (for Norway) systems power source. 10. The PSU has been evaluated for use with a Three Phase power source. 11. The secondary output of all the PSU is SELV except for model TXP which output is at hazardous voltage. TXP4000 output is still at hazardous voltage after disconnection at no load condition. Output can only be accessible after 2 minutes from disconnection. 12. The main output is at hazardous energy level, additional evaluation must be conducted at end system. DQD 507 Rev Page 2
3 Certificate: Project: Master Contract: Date Issued: All Isolating transformers isolation barrier insulation temperatures have been measured within the winding on the insulator. The internal temperature did not exceed the insulation Class limits for NORMAL operation and ABNORMAL operation. 14. Enclosure provided with the equipment meets FIRE and ELECTRICAL requirements except for the rear panel of models TXP3500 and TXP4000. Suitability for mechanical enclosure shall be determine at end system. 15. The PSU is not intended for use in vehicles, on board ships or aircraft. DQD 507 Rev Page 3
4 Supplement to Certificate of Compliance Certificate: Master Contract: The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description Product Certification History Update Report to add new model TXP Update report to include new model TXP Switching Power Supply, Models TCP , TCP3500-H048. (C/US) DQD 507 Rev Page 1
5 CERTIFICATE No. P Order No Page 1 of 2 Product AC-DC Converter Applicant Manufacturer Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ USA Factory (2) See page 2 Ratings TCP , TCP3500-H048, TXP Input: 12-5 A, / Vac, 3 phase, 3W+PE, 50/60Hz; TXP Input: A, / Vac, 3 Phase, 3W+PE, 50/60Hz Trade mark Model / Type Ref. Principal characteristics A sample of the product was tested and found to be in conformity with Validity Additional information TCP , TCP3500-H048, TXP , TXP TCP , TCP3500-H048, TXP output:10-50 Vdc, 73 A maximum, 3500 W maximum; TXP output: Vdc, 36.5 A maximum, 4000 W maximum. In the model name, it maybe followed by G or SXXX or SXXXG where X is from 0 to 9, indicating non-safety relative difference OFF EN :2006;A11;A1;A12;A2 This certificate documents conformity with the standards shown, and also applies as license for use of Nemkos name and certification mark. The certificate and license is valid as long as the applicable conditions are complied with, and provided that any changes to the product are notified to Nemko for acceptance prior to implementation. New standards or amendments to the standards may imply that the product design must be updated and/or that re-testing and re-certification is necessary. Additional model(s) Compliance with requirements regarding building-in, protection against electric shock and Electromagnetic Compatibility (EMC) must be checked when the equipment is built-in a completed product or forms a part of a complete system. No additional models Date of issue Juan Z. Kleppenes Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL FAX info@nemko.com ENTERPRISE NUMBER NO nemko.com
6 CERTIFICATE No. P Order No Page 2 of 2 Factories BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park, Guangming District Shenzhen China Bel Power Solutions, s.r.o. Areal ZTS 924 Dubnica nad Vahom Slovakia Date of issue Juan Z. Kleppenes Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL FAX info@nemko.com ENTERPRISE NUMBER NO nemko.com
7 Ref. Certif. No. NO95352 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI DACCEPTATION MUTUELLE DE CERTIFICATS DESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la deuxième page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) AC-DC Adapter Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ USA Additional information on page 2 TCP , TCP3500-H048, TXP Input: 12-5 A, / Vac, 3 phase, 3W+PE, 50/60Hz; TXP Input: A, / Vac, 3 Phase, 3W+PE, 50/60Hz Type of Manufacturer s Testing Laboratories used Type de programme du laboratoire d essais constructeur Model / Type Ref. Ref. De type CTF Stage 3 TCP , TCP3500-H048, TXP , TXP Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire, peuvent être indiqués sur la deuxième page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport dessais numéro de référence qui constitue partie de ce Certificat TCP , TCP3500-H048, TXP output:10-50 Vdc, 73 A maximum, 3500 W maximum; TXP output: Vdc, 36.5 A maximum, 4000 W maximum. In the model name, it maybe followed by G or SXXX or SXXXG where X is from 0 to 9, indicating non-safety relative difference Additional information on page 2 IEC :2005, IEC :2005/AMD1:2009, IEC :2005/ AMD2: This CB Test Certificate is issued by the National Certification Body Ce Certificat dessai OC est établi par l'organisme National de Certification Gaustadalléen 30 NO-0373 Oslo, Norway Date: Signature: Juan Z. Kleppenes Certification Department Issued /2
8 Ref. Certif. No. NO95352 BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park, Guangming District Shenzhen China Bel Power Solutions, s.r.o. Areal ZTS 924 Dubnica nad Vahom Slovakia Gaustadalléen 30 NO-0373 Oslo, Norway Date: Signature: Juan Z. Kleppenes Certification Department Issued /2
9 Test Report issued under the responsibility of TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Report Number.... : Date of issue... : 14 December 2016 Total number of pages Applicant s name... : Address... : Bel Fuse Inc. 206 Van Vorst St., Jersey City, New Jersey, 07302,USA Test specification: Standard... : IEC :2005 (Second Edition) + Am 1: Am 2:2013 Test procedure... : Non-standard test method... : CB-Scheme N/A Test Report Form No.... : Test Report Form(s) Originator... : IEC60950_1F SGS Fimko Ltd Master TRF... : Dated Copyright 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report. This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.
10 Page 2 of 87 Report No Test item description... : Trade Mark... : AC-DC Converter Manufacturer... : Model/Type reference... : Ratings... : Same as Applicant TCP , TCP3500-H048, TXP , TXP (may be followed by G or SXXX or SXXXG where X is from 0 to 9, indicating non-safety relative difference) TCP , TCP3500-H048, TXP : Input: 12-5 A, / Vac, 3 phase, 3W+PE, 50/60Hz Output: Vdc, 73 A maximum, 3500 W maximum TXP : Input: A, / Vac, 3 Phase, 3W+PE, 50/60Hz Output: Vdc, 36.5 A maximum, 4000 W maximum Testing procedure and testing location: CB Testing Laboratory: Nemko USA Inc. Testing location/ address... : 2210 Faraday Ave. Suite 150, Carlsbad, CA 92008, USA Test procedure: CTF-3 Bel Power Solutions s.r.o. Testing location/ address... : ArealZTS Dubnica n.vahom c Dubnica nad Vahom SLOVAKIA Tested by (name + signature)... : Editha Vergara Reviewed by (name + signature)... : George Daverin Approved by (name + signature)... : Jeff Busch
11 Page 3 of 87 Report No Report History: Original report List of Attachments (including a total number of pages in each attachment): Attachment 1: Attachment 2: European Group Differences and National Deviations pages Documented deviations contain individual national documents for several European countries that are included in the European Group Deviations. The European Group Difference: EN60950:2006/A11:2009/A1:2010/A12:2011/A2:2013 are considered Normative. The individual national documents (Denmark, Finland, Germany, Ireland, Norway, Spain, Sweden, Switzerland and United Kingdom) are considered informative and included at the manufacturer s request. Miscellaneous Documentation, e.g. Photos, PWB Layout, Schematic etc pages (Not for publication Engineering use only)
12 Page 4 of 87 Report No Summary of testing General Power Supply Units All comments relate to all models, unless specifically stated. The equipment is an enclosed, Class I switch mode AC-DC converter three phase AC input and adjustable DC output. This report covers multiple models and all comments / tests apply to all models unless otherwise indicated. Testing was conducted on various models as indicated ; The unit is intended to operate at an altitude of up to 3048m. This equipment is intended to be operated at an altitude of up to 3048 m so the clearance is multiplied by the altitude correction factor (1.15), specified in table A.2 of IEC nd Edition: Refer to Tables and , 3.2.5; Power supply cord set. Power supply is for building-in. A power supply cord set, complying with the national regulations of the country in which the product is to be sold, shall be provided with the end-use equipment ; Safety instructions. Instructions and equipment markings related to safety are to be provided in a language, which is acceptable in the country in which the equipment is to be sold. English language verified ; IT power distribution systems. The equipment complies with the requirements for connection to the Norwegian IT power systems. The following information should be given (but is not required) in the installation instruction: This product is also designed for IT power system with Phase to Phase voltage 230V ; Number and location of protective devices. In Norway, IT power distribution system is used. Equipment with a single protective device is accepted in Norway. Other countries may have additional requirements ; Warning to service personnel. After operation of the protective device, the equipment is still under voltage if it is connected to an IT-power system. A warning is required for service personnel. Norway does not require this warning. 5.2: Electric Strength test Increased test voltages for Basic insulation applied to the equipment, based on measured working voltages.
13 Page 5 of 87 Report No Summary of testing: Tests performed (name of test and test clause): 1) Input Test ) Durability Test ) Energy hazards c) 1) 4) Capacitance Discharge Test ) SELV Reliability Test ) Limited Current Circuit Test ) Protective Bonding Test ) Humidity Test ) Working Voltage Measurement ) Hazardous Voltage Measurement ) Mechanical and Stress Relief Test ) Heating Test ) Touch Current Test ) Electric Strength Test ) Component Failure Test ) Abnormal Operation Test ) PS Output Overload and Short Test ) Transformer Overload Test and Insulation. Annex C Additional testing: Model TXP G 1) Input Test ) Protective Bonding Test ) Working Voltage Measurement ) Heating Test ) Touch Current Test ) Electric Strength Test ) Abnormal Operation Test ) PS Output Overload and Short Test ) Transformer Overload Test and Insulation Annex C Testing location: Bel Power Solutions s.r.o. ArealZTS Dubnica n.vahom c Dubnica nad Vahom SLOVAKIA Testing location: Bel Power Solutions s.r.o. ArealZTS Dubnica n.vahom c Dubnica nad Vahom SLOVAKIA
14 Page 6 of 87 Report No Additional testing: Model TXP G 1) Input Test ) Energy hazards c) 1) 4) Capacitance Discharge Test ) SELV Reliability Test ) Protective Bonding Test ) Humidity Test ) Working Voltage Measurement ) Hazardous Voltage Measurement ) Mechanical and Stress Relief Test ) Heating Test ) Touch Current Test ) Electric Strength Test ) Component Failure Test ) Abnormal Operation Test ) PS Output Overload and Short Test ) Transformer Overload Test and Insulation Annex C Testing location: Bel Power Solutions s.r.o. ArealZTS Dubnica n.vahom c Dubnica nad Vahom SLOVAKIA Summary of compliance with National Differences: List of countries addressed Austria (AT), Australia (AU), Canada (CA), China (CH), Denmark (DK), Finland (FI), Germany (DE), Ireland (IE), Israel (IS), Korea (KR), Norway (NO), Slovenia (SI), Spain (ES), Sweden (SE), Switzerland (CH), United Kingdom (GB), United States of America (US) The product fulfils the requirements of : EN : A11: A1: A12: A2:2013
15 Page 7 of 87 Report No Copy of marking plate: The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective Certification Bodies that own these marks. (High Leakage warning is for TCP3500 Series only)
16 Page 8 of 87 Report No Copy of marking plate (continued): The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective Certification Bodies that own these marks. Caution Marking Model TXP4000 Calibration Measurement uncertainty Evaluation of results All instruments used in the tests given in this test report are calibrated and traceable to national or international standards. Further information about traceability will be given on request. Measurement uncertainties are calculated for all instruments and instrument set-ups given in this report. Calculations are based on the principles given in the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007 and other relevant internal Nemko-procedures. Further information about measurement uncertainties will be given on request. If not explicitly stated otherwise in the standard, the test is passed if the measured value is equal to or below (above) the limit line, regardless of the measurement uncertainty. If the measured value is above (below) the limit line, the test is not passed - ref IEC Guide 115:2007. The instrumentation accuracy is within limits agreed by IECEE-CTL.
17 Page 9 of 87 Report No Equipment mobility... : [] movable [] hand-held [] transportable [] stationary [ X ] for building-in [] direct plug-in Connection to the mains... : [] pluggable equipment [] type A [] type B [ X ] permanent connection [] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains Operating condition... : [ X ] continuous [] rated operating / resting time: Access location... : [] operator accessible [] restricted access location [ X ] Component (to be determined in the end system) Over voltage category (OVC)... : [] OVC I [ X ] OVC II [] OVC III [] OVC IV [] other: DC power Mains supply tolerance (%) or absolute mains supply values... : -10%, +10% Tested for IT power systems... : [ X ] Yes (Norway only) [] No IT testing, phase-phase voltage (V)... : 230 Class of equipment... : [ X ] Class I [] Class II [] Class III [] Not classified Considered current rating of protective device as part of the building installation (A)... : 40A (TCP3500, TXP3500), 20A (TXP4000) Pollution degree (PD)... : [] PD 1 [ X ] PD 2 [] PD 3 IP protection class... : IP20 Altitude during operation (m)... : 3048 m (10000 ft.) Altitude of test laboratory (m)... : 242 m Mass of equipment (kg)...: 6.5 kg (TCP3500) 6.2 kg (TXP3500, TXP4000) Temperature, Ambient ( C)... : 50 C of cold plate and 70 C maximum of ambient air for TCP C maximum operating ambient for TXP3500, TXP4000. Possible test case verdicts: - test case does not apply to the test object...: N/A - test object does meet the requirement... : P (Pass) - test object does not meet the requirement...: F (Fail) Testing... : Date of receipt of test item... : Date (s) of performance of tests... : to , to , to
18 Page 10 of 87 Report No General remarks: "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Manufacturer s Declaration per sub-clause of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided. : Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies)... : BPS Asia Pacific Electronics (Shenzhen) Co.,Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District Shenzhen PEOPLE'S REPUBLIC OF CHINA Bel Power Solutions s.r.o. ArealZTS Dubnica n.vahom c Dubnica nad Vahom SLOVAKIA
19 Page 11 of 87 Report No General product information: This test report replaces Nemko test report Ref. No with appended CB cert. Ref. No. NO94435 evaluated to the requirement of IEC : 2005 (Second edition)+am1:2009+am 2:2013. This test report includes the addition of model TXP G. For continuity, the entire report has been reissued, including the additional evaluation highlighted in Bold italic text. Model TCP3500 and TXP3500 Series are AC-DC converter which employ a PFC front end stage and an isolated DC-DC stage to convert 3-phase AC input voltage to a low DC O/P voltage. The PSU includes digital signal processor (DSP) which enables monitoring of electrical parameters (including input voltage of all 3 phases) and controlling the PSU from system controller. An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller. The unit composed of AC filter board, DC/DC main board, Power board, Secondary main board and Control board. Testing conducted on TCP G represents models TCP3500-H048G. TCP3500 Series is provided with an Aluminium water cooled cold plate to aid in cooling the power supply. The water is contained within the cold plate and water does not circulate through the power supply. Power supply is mounted on the cold plate and the power supply is cooled by convection. Water is intended to be cooled to maintain the cold plate at 50 C. TXP3500 Series is provided with internal fan for cooling. The unit is operated at maximum 55 C ambient. Model Differences: Model TCP3500-H048G is same as TCP G except it contains output post filter (added L301, D318 and R342 R347) on the secondary main board for better dynamic regulation parameters and three 30A fuses (F300, F301, F302) instead one 80A fuse (F300) used on TCP G model. Model TXP is exactly the same as TCP except for the enclosure design, cooling method, operating ambient, PCB layouts due to slight changes on control circuits, different auxiliary transformer, some SELV components and PWB assemblies. Model TXP G is exactly the same as TXP except input and output ratings, main transformer part number and secondary PCB layouts.
20 Page 12 of 87 Report No CONDITIONS OF ACCEPTABILITY: Model(s) require: 1. The equipment has been evaluated for use in Pollution Degree 2 environment. 2. The Clearance values of the Power Supply Unit (PSU) have been evaluated for an altitude of 10,000ft (3048m), under IEC : 1992 Table A.2 (altitude correction factor is 1.15). 3. Touch Current Test was conducted at 305/520Vac, 60Hz and measured current for single unit was 3.5mA. Earth connection is essential before connecting the power supply. Requirements for high leakage current warning labeling to be evaluated in end-use equipment. 4. The Capacitance Discharge Test was conducted on the mains input, the requirements of UL /CSA were met. 5. The ground path from the appliance inlet to the PSU case meets protective bonding and has been evaluated at 80 A for TCP3500, TXP3500 models and 40 A for TXP Evaluated as Class I (earthed equipment). Reliable connection to Protective Earth shall be provided in the end use installation. 7. Evaluated for connection to AC power with a branch circuit protection rated max 40A for models TCP3500 and TXP3500 and max. 20 A for model TXP The PSU has been evaluated for a TN (Including TN-S and TN-C), IT (for Norway) systems power source. 9. The PSU has been evaluated for use with a Three Phase power source (3W+PE). 10. The output of Models TCP3500 and TXP3500 is SELV. 11. The outputs (10-50V) of Models TCP3500 and TXP3500 are at hazardous energy level, but when removed from the end use product, with no connections to the secondary connectors, the outputs are not an energy hazard even under single fault conditions. 12. The output of Model TXP is at hazardous voltage. TXP4000 output is still at hazardous voltage after disconnection at no load condition. Output can only be accessible after 2 minutes from disconnection. 13. All Isolating transformers isolation barrier insulation temperatures have been measured within the winding on the insulator. The internal temperature did not exceed the insulation Class limits for NORMAL operation and ABNORMAL operation. 14. Enclosure provided with the equipment meets FIRE and ELECTRICAL requirements except for the rear panel of models TXP3500 and TXP4000. Suitability for mechanical enclosure shall be determine at end system. 15. The PSU is not intended for use in vehicles, on board ships or aircraft. Abbreviations used in the report: - normal conditions... N.C. - single fault conditions... S.F.C - functional insulation... OP - basic insulation... BI - double insulation... DI - supplementary insulation... SI - between parts of opposite polarity... BOP - reinforced insulation... RI Indicate used abbreviations (if any): None
Certificate of Compliance
Certificate of Compliance Certificate: 70036125 Master Contract: 170351 Project: 70156820 Date Issued: 2017-09-21 Issued to: Bel Fuse Inc. 206 Van Vorst St Jersey City, New Jersey 07302 USA Attention:
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70036130 (170351) Master Contract: 170351 Project: 70044582 Date Issued: 2015-09-02 Issued to: Bel Fuse Inc. 206 Van Vorst St Jersey City, New Jersey 07302 USA Attention:
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2235802 (LR 38879) Master Contract: 173688 Project: 2235802 Date Issued: 2009/11/03 Issued to: Power-One, Inc 740 Calle Plano Camarillo, CA 93012 USA Attention: Ms.
More informationFile E Vol. 1 Sec. 125 Page 1 Issued: and Report Revised:
File E131905 Vol. 1 Sec. 125 Page 1 Issued: 2007-04-18 and Report Revised: 2009-04-24 DESCRIPTION PRODUCT COVERED: USR, CNR - Switching Power Supply, Models SPASUNM-03, SPASUNM-07, SFP1050-12B, may be
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-2 CB DE1-49619/A2/B1/M2 Date
More informationAmendment to Test Report
Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294
More informationAmendment to Test Report
Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: T223-0035/16 Date of issue...: 2016-02-01
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY
More informationTEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements
Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
dftfdthdxfgxfx Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31182226.016 Date of issue...
More informationTEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements
Issue Date: 2015-06-26 Page 1 of 73 Report Reference # E122103-A140-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment
More informationTEST REPORT IEC Part 1: General requirements for basic safety and essential performance
jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...
More informationPower Supply XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA
Ref. Certif. No. US-18342-UL IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS DES EQUIPEMENTS
More informationTEST REPORT IEC Part 1: General requirements for basic safety and essential performance
Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information
More informationCA/11022/CSA. Lineage Power N/A. Ref. Certif. No. Component DC-DC Converters for Use With ITE
IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D ACCEPTATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE
More informationTEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements
Issue Date: 2017-10-20 Page 1 of 72 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires
Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular
More informationTEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements
Issue Date: 2017-10-20 Page 1 of 11 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2012-08-17 Page 1 of 21 Report Reference # E186249-A203-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information
More informationZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :
Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report
More informationSPECIFIC TECHNICAL CRITERIA
Issue Date: 2007-01-23 Page 4 of 57 Report Reference # E116994-A34-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL 60601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference
More informationCOVER PAGE FOR TEST REPORT
Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): COVER PAGE FOR TEST REPORT Power Supplies for Information Technology Equipment Including Electrical Business
More informationInstallation Couplers intended for permanent connection in fixed installation
Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment
More informationENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue
ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE
More informationTEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires
TEST REPORT PN-EN 13032 Light and lighting. Measurement and presentation of photometric data of lamps and luminaires Report Number.... : BS-3/161/B/5/15 Date of issue... : 03.02.2016 Total number of pages...
More informationTesting Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.
11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology
More informationPage 2 of 23 UNT150420C11
Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...
More informationTEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60884-1 Plugs and socket-outlets for household and similar purposes Part 1: General requirements Report Reference No.... : Date of issue...
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :
More informationAustralian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas
AS 62040.1.1 2003 IEC 62040-1-1:2002 IEC 62040-1-1:2002/Corr.1:2002 Reconfirmed 2013 AS 62040.1.1 Australian Standard Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS
More informationAS/NZS AS/NZS
TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total
More informationTest Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...
Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and
More informationDK M2-UL. Ref. Certif. No. CB TEST CERTIFICATE CERTIFICAT D ESSAI OC. Date: Original Issue Date:
Ref. Certif. No. DK-28210-M2-UL IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D ACCEPTATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIPEMENTS
More informationINSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.
INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1271882 Master Contract: 165071 Project: 2429855 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention: Mr. Michael
More informationPage 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.
12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...
More informationTEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000
Page 1 of 15 Report No 130313TRFENV Report Reference No.... : TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 130313TRFENV Tested by... : Alessio Pelizzoni. Verified by... : Fabio Mauri. Date of issue...
More informationTEST REPORT IEC Part 1: General requirements for basic safety and essential performance
Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : 50088663 001 Date of issue... : 2017-08-09
More informationLVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.
LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.
More informationInformation technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements
More informationTEST REPORT DIN V VDE V
Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...
More informationTEST REPORT DIN V VDE V
Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...
More informationEU RO Mutual Recognition Technical Requirements
1. PRODUCT DESCRIPTION... 1 2. DESIGN EVALUATION... 2 3. PRODUCTION REQUIREMENTS... 6 4. MARKING REQUIREMENTS... 6 5. TYPE APPROVAL CERTIFICATE CONTENT... 7 6. APPROVAL DATE AND REVISION NUMBER... 7 7.
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):
More informationSGS Australia Pty Ltd
TEST REPORT AS/NZS 60598.2.2:2001 Luminaires Part 2: Particular requirements Recessed luminaires Report Reference No....: S08007 Approved by (+ signature)...: I Absolom Date of issue...: Thursday, 31 January
More informationPLUG-IMQ 3/4
PLUG-IMQ 2/4 PLUG-IMQ 3/4 PLUG-IMQ 4/4 PLUG-KEMA 1/3 PLUG-KEMA 2/3 PLUG-KEMA 3/3 CERTIFICATE No. P12215783 Order No. 218230 Page 1/4 Product Applicant Manufacturer Factory Plugs Volex (Asia) Pte Ltd. 35
More informationINSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.
INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power
More informationNovitaTech Engineering
NovitaTech Engineering 490869 TEST REPORT FOR PDG Product Design Group Eclipse 600 MANUAL WHEELCHAIR TEST DOCUMENTS AS3695:1992, AS3696-1:1990, AS 3696-3:1990, AS 3696-5:1989, AS 3696-8:1998, ISO 7176-7:1996
More informationCertificate of Compliance
FF0 002 Certificate of Compliance Issued to: Rotork Controls Inc. 675 Mile Crossing Blvd Rochester, NY 14624 USA Attention: Matt Cogill The products listed below are eligible to bear the CSA Mark shown
More informationThis document is a preview generated by EVS
TECHNICAL SPECIFICATION CLC/TS 50457-1 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION March 2008 ICS 43.120 Supersedes ENV 50275-2-3:1998 English version Conductive charging for electric vehicles - Part
More informationInstallation Couplers intended for permanent connection in fixed installation
age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70054084 Issued to: Emerson - Rosemount, Micro Motion Inc. 12001 Technology Dr. Eden Prairie, Minnesota 55344 USA Attention: Paul Schilke The products listed below
More informationTEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors
r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of
More informationIEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,
More informationTest Report issued under the responsibility of: Report Number...:
Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and
More informationSCXI Power Supply/Float Charger Installation Guide
SCXI -1383 Power Supply/Float Charger Installation Guide Conventions This guide describes how to install and use the SCXI-1383 power supply/float charger. The SCXI-1383 is a 13.8 VDC, 4 A power supply/float
More informationRUZ- _/_ Protection (3) Isolation Option (4)
Features Unregulated Converters Description Dual output from a single input rail 1kVDC or 2kVDC input/output basic isolation 1kVDC output/output isolation Power sharing on outputs Optional continuous short
More information< > Page 2 of 84
age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes
More informationIntertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc.
Test Report issued under the responsibility of: TEST REORT IEC 62133, First Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed
More informationThis document is a preview generated by EVS
TECHNICAL SPECIFICATION CLC/TS 50535 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION April 2010 ICS 45.060.01 English version Railway applications - Onboard auxiliary power converter systems Applications
More informationDALI 650mA LED Driver
Installation Guide DGLC650C18DD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095
More informationISO :2015/DAM 1
DRAFT AMENDMENT ISO 19973-2:2015/DAM 1 ISO/TC 131 Voting begins on: 2018-01-15 Secretariat: ANSI Voting terminates on: 2018-04-09 Pneumatic fluid power Assessment of component reliability by testing Part
More informationRECHARGEABLE LITHIUM-ION BATTERIES FOR SYSTEMS
RECHARGEABLE LITHIUM-ION BATTERIES FOR SYSTEMS CERTIFICATION UPDATES Rich Byczek, 11/15/11 1 Agenda IEC 62133 adoption, transition Certification options for Lithium-Ion Batteries End product requirements
More informationEurocode 2 Design of concrete structures
BRITISH STANDARD BS EN 1992-3:2006 Eurocode 2 Design of concrete structures Part 3: Liquid retaining and containment structures The European Standard EN 1992-3:2006 has the status of a British Standard
More informationTest Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND
Reference No.: WTF16F0961094C age 2 of 5 Test Results: Test Item(s) Unit Test Result No.1 MDL Maximum Allowable Limit Lead (b) % ND 0.0002 See comment if > 0.004 % Cadmium (Cd) % ND 0.0002 0.002 Mercury
More informationISO 1217 INTERNATIONAL STANDARD. Displacement compressors Acceptance tests. Compresseurs volumétriques Essais de réception. Fourth edition
INTERNATIONAL STANDARD ISO 1217 Fourth edition 2009-07-01 Displacement compressors Acceptance tests Compresseurs volumétriques Essais de réception Reference number ISO 1217:2009(E) ISO 2009 PDF disclaimer
More informationThis document is a preview generated by EVS
TECHNICAL SPECIFICATION ISO/TS 19425 First edition 2015-12-15 Reciprocating internal combustion engines Measurement method for air cleaners Sound power level of combustion air inlet noise and insertion
More informationISO 3934 INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 3934 Second edition 2002-09-01 Rubber, vulcanized and thermoplastic Preformed gaskets used in buildings Classification, specifications and test methods Caoutchouc vulcanisé et
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 16183 First edition 2002-12-15 Heavy-duty engines Measurement of gaseous emissions from raw exhaust gas and of particulate emissions using partial flow dilution systems under
More informationThree-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U
Instruction Manual Supplement for FRN-C2S-2U/4U (7.5 to 20 HP) Compact Inverter 200 V series: FRN0025 to 0060C2S-2U series: FRN0013 to 0030C2S-4U Thank you for purchasing our FRENIC-Mini series of inverters.
More informationISO INTERNATIONAL STANDARD. Road vehicles Test methods for electrical disturbances from electrostatic discharge
INTERNATIONAL STANDARD ISO 10605 First edition 2001-12-15 Road vehicles Test methods for electrical disturbances from electrostatic discharge Véhicules routiers Méthodes d'essai des perturbations électriques
More informationCertificate of Compliance
FF0001 Certificate of Compliance Certificate: 1345550 Issued to: Eaton Electric Ltd. Great Marlings Butterfield, Luton Bedfordshire LU2 8DL United Kingdom Attention: Mr. Peter Rigling The products listed
More informationTHE HEARTBEAT B E H I N D T H E HEARTBEAT MEDICAL POWER BROCHURE
THE HEARTBEAT B E H I N D T H E HEARTBEAT MEDICAL BROCHURE A B O U T EOS P O W E R EOS Power has been designing standard, modified and custom medical power solutions for the global medical market for
More informationISO INTERNATIONAL STANDARD. Hoists for the transfer of disabled persons Requirements and test methods
INTERNATIONAL STANDARD ISO 10535 Second edition 2006-12-15 Hoists for the transfer of disabled persons Requirements and test methods Lève-personnes pour transférer des personnes handicapées Exigences et
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 19453-1 First edition 2018-03 Road vehicles Environmental conditions and testing for electrical and electronic equipment for drive system of electric propulsion vehicles Part
More informationElectric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT
Date of publication: 1 November 2016Not yet published Issued by: Mark Wogan, Manager Energy Safety WorkSafe New ZealandNot yet issued Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals
More informationABB France 3 rue Jean Perrin CS CHASSIEU Cedex FRANCE. Eppelheimer Str HEIDELBERG - ALLEMAGNE. Contacteur Contactor
LCIE N : Titulaire : License Holder: Site de fabrication : Factory: ABB France 3 rue Jean Perrin CS 90009 69687 CHASSIEU Cedex FRANCE ABB STOTZ KONTAKT GmbH Eppelheimer Str. 82 69123 HEIDELBERG - ALLEMAGNE
More informationDycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD
Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain
More informationEvaluation Certificate
SC0414-14 Certificate for a part of a measuring system for LOTW Forecourt controller, FuelNet Manager Issued to CODAB AB Höjdrodergatan 24, SE-212 39 Malmö, Sweden In respect of (part of instrument) Forecourt
More informationAMENDMENTS TO BUNKER DELIVERY NOTE TO PERMIT THE SUPPLY OF FUEL OIL NOT IN COMPLIANCE WITH REGULATION 14 OF MARPOL ANNEX VI
E SUB-COMMITTEE ON POLLUTION PREVENTION AND RESPONSE 3rd session Agenda item 10 PPR 3/10 10 December 2015 Original: ENGLISH AMENDMENTS TO BUNKER DELIVERY NOTE TO PERMIT THE SUPPLY OF FUEL OIL NOT IN COMPLIANCE
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2049843 (LR 12730-263) Master Contract: 165071 Project: 2460955 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention:
More informationLoad (2) Single or Dual
Features Regulated Converter Reinforced insulation for 25VAC working voltage Clearance and creepage distance >8.mm 5kVAC I/P to O/P 2MOPP isolation 2µA patient leakage current Industry standard pinout
More informationDEUTSCHE NORM June Plastics Symbols and abbreviated terms Part 1: Basic polymers and their special characteristics (ISO : 2001)
DEUTSCHE NORM June 2002 Plastics Symbols and abbreviated terms Part 1: Basic polymers and their special characteristics (ISO 1043-1 : 2001) English version of DIN EN ISO 1043-1 { EN ISO 1043-1 ICS 01.040.83;
More informationRental Industry Safety Tester Safe Check 5s
Rental Industry Safety Tester Safe Check 5s Feb 2006 2006 Clare Instruments Inc. Issue 2.0 Firmware Version : 1.2a Limited Warranty & Limitation of Liability Clare Instruments Inc, guarantees this product
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. M4T28-BR12SH M4T32-BR12SH TIMEKEEPER SNAPHAT (BATTERY & CRYSTAL) FEATURES
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 10924-2 First edition 2014-02-15 Road vehicles Circuit breakers Part 2: User s guide Véhicules routiers Coupe-circuits Partie 2: Guide de l utilisateur Reference number ISO 10924-2:2014(E)
More informationFeatures. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter
Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation
More information