THE HEARTBEAT B E H I N D T H E HEARTBEAT MEDICAL POWER BROCHURE

Size: px
Start display at page:

Download "THE HEARTBEAT B E H I N D T H E HEARTBEAT MEDICAL POWER BROCHURE"

Transcription

1 THE HEARTBEAT B E H I N D T H E HEARTBEAT MEDICAL BROCHURE

2

3 A B O U T EOS P O W E R EOS Power has been designing standard, modified and custom medical power solutions for the global medical market for 2 years. We understand and implement unique electrical, quality and safety requirements of medical customers into our broad range of Class I and Class II medically approved power solutions. This focused design effort has resulted in a range of best in class medically approved power solutions which allow medical customers huge flexibility when making critical decisions on their choice of power source. The current EOS medical power range can offer power solutions from 2 to 0 watts with many unique footprints, power densities and specifications. Let EOS power your medical applications! Our best in class support, products and warranties all come as standard.

4 S T A N D A R D MEDICAL P O W E R S O L U T I O N S The EOS standard medical power supplies are available in industry standard footprints such as 2 x 4 inches, 3 x inches, 4 x 6 inches and the NEW 2 x 3 x 0.7 inches format. EOS Power offers end customers standard specifications such as Class II product options and a BF rating (Body Floating) on higher power products which are not available from many alternate suppliers. Adding these specifications to the standard high efficiency, high power density and full medical approvals ensures that EOS is a leader in providing standard medical power solutions.

5 MWLC Conduction Rated Arctic Series The EOS MWLC Conduction Rated Arctic Series addresses the growing demand in the market for conduction rated power supplies. The MWLC Arctic Series again sees EOS Power deliver industry leading power densities and specifications in an industry standard 3 x inches footprint: 0 watts of EOS Power in 22. cubic inches which can be used in conduction, convection or forced-air modes of operation. MWLP Low Profile Blue Series with Extended Warranty Option The MWLP Blue Series offers the size conscious customer industry leading watts per cubic inch in height profiles ranging from mm to 2 mm in industry standard footprints. The Blue Series allows customers shrink their applications without compromising on power, quality or functionality. The Blue Series also comes with an extended warranty option: customers can choose their MWLP product with an extended warranty period of seven years. MWLT Economical Green Series The EOS Power Economical Green Series was designed with the value focused customer in mind. The MWLT Green Series offers market leading specifications in industry standard footprints at very competitive price levels. While cost is important to many end users, EOS does not compromise on quality or workmanship which makes the Green Series the perfect choice for the quality and cost conscious customer. MULP Ultra Low Profile Orange Series The EOS Power Ultra Low Profile Orange Series sets new height profile benchmarks in the power supply industry with a maximum height of just 0.7 inches (that s an incredible 19.0 mm). The MULP Orange Series packs up to watts per cubic inch into their small profiles which enables customers miniaturize their applications without compromising on available power levels. While still maintaining the 0.7 inch product height, the Orange Series is also available with Power Good and Power Fail signaling capability.

6 M O D I F I E D MEDICAL P O W E R S O L U T I O N S EOS Power offers low barrier of access to modification capabilities and value added engineering services. We understand and support that not all end customer requirements will be satisfied by a standard medical product alone. EOS Power specializes in providing end customers a total power solution whether that is changing voltages, adding functionality, mechanical additions or manufacturing solutions. Modifications and value added medical power solutions are an EOS Power specialty. We have supplied non-standard solutions to global medical customers for over two decades. Contact EOS Power for more details of how to get a fast quotation for your value added medical solution.

7 C U S T O M I Z E D MEDICAL P O W E R S O L U T I O N S EOS Power has dedicated custom power resources which are available to quote unique medical power supply requirements. Our years of experience in medical power supply design and production can help our customers choose the best design solution for their requirements. EOS Power works in parallel with the end customer to agreed timeline and milestone targets and supports the customer throughout the lifetime of the product application. EOS personnel are available to quote medical custom design requirements upon receipt of a full product specification. Contact EOS Power if you require custom medical solutions which are delivered to specification, on time and within budget.

8 40 60 WATTS PRODUCT FEATURES MODEL NUMBER VOLTAGE EFFICIENCY (%) NO- MULP40 3 x 2 x 0.7 Inches 40 W Temperature PCB Mounting Option EN :20 MULP40 0 MULP40 1* MULP40 MULP40 13* MULP40 MULP40 13* MULP40 MULP40 13* MULP40 MULP40 13* MULP40 MULP40 13* MULP MULP40 138* MWLT40 Single & Triple Output 4 x 2 x 1.2 Inches 40 W No Load Power 0.3 W (Single Output) Dual Fusing LFMWLT40 00 LFMWLT40 01 LFMWLT40 02 LFMWLT40 03 LFMWLT40 04 LFMWLT40 00 LFMWLT40 01 LFMWLT40 02 LFMWLT ,.,.8.2,,.8.2, 14.6, ,.2, , 2.0, , 1.0, , 1., , 3.0, EN :20 MWLT60 Single & Triple Output 4 x 2 x 1.2 Inches 0 to 6 W Convectioncooled No Load Power 0.3 W (Single Output) Dual Fusing LFMWLT60 00 LFMWLT60 01 LFMWLT60 02 LFMWLT60 03 LFMWLT60 04 LFMWLT60 00 LFMWLT60 01 LFMWLT60 02 LFMWLT ,.,.8.2,,.8.2, 14.6, ,.2, , 3.0, , 1., , 2., , 3.0, EN :20

9 7 0 WATTS PRODUCT FEATURES MODEL NUMBER VOLTAGE EFFICIENCY (%) NO- MWLP7 3 x 2 x 1 Inches 7 W Efficiencies up to % Temperature, Thermal Shutdown Dual Fusing Screw Terminal & Header LFMWLP7 01 LFMWLP7 11* LFMWLP7 02 LFMWLP7 12* LFMWLP7 03 LFMWLP7 13* LFMWLP7 04 LFMWLP7 14* LFMWLP7 0 LFMWLP7 1* LFMWLP7 06 LFMWLP7 16* Type Connector Options EN :20 PRODUCT FEATURES MODEL NUMBER VOLTAGE (convection) EFFICIENCY (forced-air) (%) NO- MWLP0 3 x 2 x 1.18 Inches 0 W Forced-air & 0 W Efficiencies up to % Temperature Dual Fusing Screw Terminal & Header LFMWLP0 01 LFMWLP0 11* LFMWLP0 02 LFMWLP0 12* LFMWLP0 03 LFMWLP0 13* LFMWLP0 04 LFMWLP0 14* LFMWLP0 0 LFMWLP0 1* LFMWLP0 06 LFMWLP0 16* Type Connector Options EN :20

10 0 1 WATTS PRODUCT FEATURES MODEL NUMBER VOLTAGE (convection) (forced-air) EFFICIENCY (%) NO- MWLT0 4 x 2 x 1.32 Inches 0 W Forced-air & 0 W Screw Terminal & Header Type Connector Options V Fan Output LFMWLT0 00 LFMWLT0 LFMWLT0 01 LFMWLT0 11 LFMWLT0 02 LFMWLT0 12 LFMWLT0 03 LFMWLT0 13 LFMWLT0 04 LFMWLT EN :20 MULP1 PGPF 4 x 2. x 0.7 Inches 1 W Forced-air & 0 W Power Good & Power Fail Signal Temperature MTBF > 3 m hours as per Telcordia SR-332 Issue 3 MULP1 00 MULP1 03* MULP1 00 MULP1 03* MULP1 00 MULP1 03* MULP1 00 MULP1 03* MULP1 00 MULP1 03* MULP1 008 MULP1 038* V Fan Output EN :20

11 1 22 WATTS PRODUCT FEATURES MODEL NUMBER VOLTAGE (convection) (forced-air) EFFICIENCY (%) NO- MULP1 4 x 2 x 0.7 Inches 1 W Forced-air & 0 W Screw Terminal & Header Type Connector Options V Fan Output EN :20 MULP1 MULP1 13* MULP1 MULP1 13* MULP1 MULP1 13* MULP1 MULP1 13* MULP1 MULP1 13* MULP1 8 MULP1 138* MWLT200 Single Ouptut x 3 x 1. Inches 200 W Forced-air & 160 W Leakage current ua Screw Terminal & Header Type Connector Options V Fan Output V Standby Output LFMWLT LFMWLT200 LFMWLT LFMWLT LFMWLT LFMWLT LFMWLT LFMWLT LFMWLT LFMWLT LFMWLT200 0 LFMWLT MWLP22 4 x 2 x 1 Inches 22 W Forced-air & 1. W 7 Years Extended Warranty Option Temperature MTBF > 3.37 m hours as per Telcordia SR-332 Issue 3 LFMWLP22 01 LFMWLP22 11* LFMWLP22 02 LFMWLP22 12* LFMWLP22 03 LFMWLP22 13* LFMWLP22 04 LFMWLP22 14* LFMWLP22 0 LFMWLP22 1* LFMWLP22 06 LFMWLP22 16* V Fan Output EN :20

12 27 WATTS PRODUCT FEATURES MODEL NUMBER VOLTAGE (convection) (forced-air) EFFICIENCY (%) NO- MULP27 PGPF x 3. x 0.7 Inches 27 W Forced-air & 0 W Power Good & Power Fail Signal Temperature MTBF > 3 m hours as per Telcordia SR-332 Issue 3 MULP27 00 MULP27 03* MULP27 00 MULP27 03* MULP27 00 MULP27 03* MULP27 00 MULP27 03* MULP27 00 MULP27 03* MULP MULP27 038* V Fan Output EN :20 MULP27 x 3 x 0.7 Inches 27 W Forced-air & 0 W Temperature MTBF > 3 m hours as per Telcordia SR-332 Issue 3 V Fan Output MULP27 MULP27 13* MULP27 MULP27 13* MULP27 MULP27 13* MULP27 MULP27 13* MULP27 MULP27 13* MULP27 8 MULP27 138* EN :20

13 0 30 WATTS PRODUCT FEATURES MODEL NUMBER VOLTAGE (convection) (forced-air) EFFICIENCY (%) NO- MWLT0 3 x x 1. Inches Up to 32 W Forced-air & 200 W LFMWLT LFMWLT LFMWLT LFMWLT LFMWLT LFMWLT V Fan Output V Standby Output EN :20 MWLP30 x 3 x 1 Inches 30 W Forced-air & 200 W 7 Years Extented Warranty Option Temperature Thermal Shutdown MTBF > 2.6 m hours as per Telcordia SR-332 Issue 3 LFMWLP30 01 LFMWLP30 11* LFMWLP30 02 LFMWLP30 12* LFMWLP30 03 LFMWLP30 13* LFMWLP30 04 LFMWLP30 14* LFMWLP30 0 LFMWLP30 1* LFMWLP30 06 LFMWLP30 16* V Fan Output Screw Terminal & Header Type Connector Options EN :20 * with Molex Connector ** suffix "-II" at the end of model number is required for the Class II option

14 40 0 WATTS PRODUCT FEATURES MODEL NUMBER VOLTAGE (convection) (forced-air) EFFICIENCY (%) NO- MWLT40 4 x 6. x 1.6 Inches U-Channel, Top & Side Fan Options OR-ing MOSFET Option Dual Fusing Optional Active Current Sharing V Standby Output Power Good & Power Fail Signal Remote ON/OFF EN :20 LFMWLT40 00 LFMWLT40 01 LFMWLT40 02 LFMWLT40 03 LFMWLT40 04 LFMWLT40 0 LFMWLT40 00 T LFMWLT40 01 T LFMWLT40 02 T LFMWLT40 03 T LFMWLT40 04 T LFMWLT40 0 T LFMWLT40 00 S LFMWLT40 01 S LFMWLT40 02 S LFMWLT40 03 S LFMWLT40 04 S LFMWLT40 0 S PRODUCT FEATURES MODEL NUMBER VOLTAGE (convection) (conduction) (forced-air) EFFICIENCY (%) NO- MWLC0 MWLC < 1 < 2 < 0.7 x 3 x 1. Inches 0 W Forced-air, 20 W Conduction & 0 W MWLC < 1 < 2 < 0.7 Hybrid Cooling Design MWLC < 1 < 2 < 0.7 Temperature V Fan Output Thermal Shutdown MWLC0 1 < 1 < 2 < 0.7 Multiple Mounting Options MWLC < 1 < 2 < 0.7 EN :20 MWLC < 1 < 2 < 0.7

15 Quick Reference Safety Approvals IEC :200 (ed.3);am1 Guidance The latest version of is the 3rd edition+am1 which was first published in December 200. The standard has been adapted in the major countries/regions of the world and published as the following versions: EU: EN :2006 USA: Isolation & Separation - IEC :200 Insulation Basic (1 x MOP) Double or Reinforced (2 x MOP) ANSI/AAMI ES :200; AMD1:20 Canada: CSA-C22.2 No :08; No :14 Currently equipment are approved to 3rd editions of the standard MOOP Air Creepage Clearance Distance Test Voltage MOPP Air Creepage Clearance Distance Test Voltage 2.0 mm 3.2 mm 00 VAC 2. mm 4.0 mm 00 VAC 4.0 mm 6.4 mm 00 VAC.0 mm 8.0 mm 4000 VAC Insulation test voltages based on 20 VAC working voltage MOP = Means of protection MOOP = Means of operation protection MOPP = Means of patient protection Emission and Immunity Specifications IEC 011/022 IEC IEC IEC IEC IEC IEC IEC IEC IEC Leakage Currents Earth leakage Enclosure leakage Patient leakage Leakage Current Earth* Enclosure Patient Limits for conducted and radiated emissions Limits for harmonic current emissions Limitation of voltage changes, voltage variations & flicker Electrostatic discharge immunity Radiated immunity Electrical fast transient immunity Electrical surge immunity Conducted disturbance immunity Immunity to power frequency magnetic field Immunity to voltage dips, short interruptions and variations on supply line Current flowing in the earth conductor Current flowing to the earth via the patient from the enclosure Current flowing to the earth via the patient from an applied part NC TYPE B SFC TYPE BF TYPE CF NC SFC NC SFC 000 µa ma 000 µa ma 000 µa ma 0 µa 00 µa 0 µa 00 µa 0 µa 00 µa 0 µa 00 µa 0 µa 00 µa 0 µa 00 µa NC = Normal Conditions SFC = Single Fault Conditions *Typical EOS µa C L A S S I a n d C L A S S I I What are the Classifications for Protection against Electric Shock? There are two classifications that fall under sub-clause 6.2 of the standard: 1) the Power Source and 2) Applied Parts. Power sources can be an external power source and is either classified as a Class I or Class II Medical Equipment or an internal power source, which is classified as Internally Powered Medical Equipment. Power Sources: External Class I, External Class II or Internal: Class I provides its protection against electric shock by having an additional safety ground (known as Protectively Earthed) that is connected to the internal and/or external conductive parts (metal) of the power source. Class II provides its protection against electric shock by having an additional layer of insulation beyond that of Basic Insulation (a single layer of insulation), and is provided either by Double Insulation (two layers of insulation) or by Reinforced Insulation (the same as Double Insulation, but as one insulation system that is twice as thick, typically). An Internal Power Source is typically a battery. I E C ( e d. 3 ) ; a m 1 The third edition of IEC is filled with new and revised requirements. Particularly manufacturers who had been operating using the second edition of the standard will find the most significant changes in four sections of the revision. These sections are general requirements (clause 4), electrical safety (clause 8), mechanical safety (clauses 9 & ) and thermal and fire safety (clause 11). Clause 4: General Requirements: The most important change in the third edition s general requirements is that manufacturers must apply risk management (in accordance with ISO 14971) to the device being certified to the third edition of This requirement, found in clause 4.2, combines for the first time the need to comply with both, a product and a process standard. Clause 8: Electrical Safety: In the third edition basic and double/reinforced insulations have been replaced by one or two means of (patient and operator) protection. The requirements that the insulation must meet depend on who is being protected. For means of patient protection the third edition sets essentially the same requirements as the second edition. One means of patient protection in the third edition is equal to the second edition s basic insulation. The third edition s two means of patient protection is equal to double/reinforced insulation in the second edition. Clauses 9 and : Mechanical Safety: Mechanical requirements of the third edition contain considerable detail and address a far broader range of specific hazards. One of the most notable additions to the mechanical requirements deals with pinching and shearing caused by moving parts. Third edition also adds new requirements and tests. Clause 11: Thermal and Fire Safety: Range of limits based on the thermal properties of the material and the likely duration of contact. The limit for these parts is a maximum of 86 ºC for materials such as wood, where contact is 1 minute or less, and a minimum of ºC for all materials where contact will be minutes or more. Contact duration must be evaluated and documented in the risk management file. In conclusion for EOS: The third edition of IEC represents a major step forward in medical device standardization. Requiring the use of ISO for risk management ensures that manufacturers can meet the implied requirement of the second edition to look for hazards beyond those addressed in the standard. It also ensures that this can be done using a consistent process. The same applies for cases in which designers want to address a hazard using techniques that differ from those identified in the standard. In general, the flexibility specifically allowed in most of the requirements in the third edition should help to create new devices efficiently and at a reasonable and competitive cost. However, the standard has changed radically. It is crucial that design teams begin to become familiar with the document and here at EOS we provide this support.

16 EOS NORTH AMERICA: EOS EUROPE: EOS ASIA-PACIFIC: EOS INDIA:

Load (2) Single or Dual

Load (2) Single or Dual Features Regulated Converter Reinforced insulation for 25VAC working voltage Clearance and creepage distance >8.mm 5kVAC I/P to O/P 2MOPP isolation 2µA patient leakage current Industry standard pinout

More information

2019 Medical Power Solutions Product Portfolio

2019 Medical Power Solutions Product Portfolio 09 Medical Power Solutions Product Portfolio Company Profile TRACO Electronic AG is a Swiss company with headquarters based in Baar, Switzerland. As a leading power supply specialist with more than 35

More information

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS FEATURES 2:1 Wide Input Voltage Range: 4.5-12 Input, 9-18 and 18-36 and 36-75 5000Vac Input to Output 2MOPP Isolation Remote On/Off

More information

C B. Operating up to 5000m altitude 5 year product warranty Models

C B. Operating up to 5000m altitude 5 year product warranty Models DC/DC Converter Wide 2:1 input voltage 6 W DC/DC converter in a compact DIP-24 plastic case I/O isolation 5000 VACrms rated for 250 VACrms working voltage Certification according to IEC/EN/ES 60601-1 3rd

More information

Testing Power Supplies for Medical Electronics Applications

Testing Power Supplies for Medical Electronics Applications white pƒper Testing Power Supplies for Medical Electronics Applications g Introduction The international stard IEC 60601 specifies testing performance for electrical devices used in medical applications.

More information

CHAPTER 2: ELECTRICAL SAFETY

CHAPTER 2: ELECTRICAL SAFETY CHAPTER 2: ELECTRICAL SAFETY 2.1 Physiological Effect of Electricity 2.2 Macroshock and Microshock Macroshock Microshock 2.3 Approaches toward Protection against Shock 2.4 Medical Safety Test Electrical

More information

Features. Description. Table of Contents

Features. Description. Table of Contents Features Very low profile Very high efficiency (typically 90%) Single and dual output versions Input voltages from 24V to 110VDC nominal voltages from 5V to 48VDC -40 C to +71 C operation without de-rating

More information

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating ECP180 Series Low 1 Profile High Power Density 2.0 by 4.0 Footprint 120W Convection-cooled Rating 180W Force Cooled Rating Medical & ITE pprovals Class I and Class II pplications High Efficiency, up to

More information

Product Portfolio 2017 Medical

Product Portfolio 2017 Medical Product Portfolio 2017 Medical PAGE 2 TRACO POWER products for applied versus non-applied medical requirements For non-applied parts sections of medical equipment, power and safety requirements can be

More information

Investigation into UK socket-outlets incorporating USB charging points

Investigation into UK socket-outlets incorporating USB charging points Investigation into UK socket-outlets incorporating USB charging points Electrical Safety First investigated a number of commercially available UK socket-outlets incorporating USB ports, as a repeat of

More information

N2POWER XLM500 AC-DC SERIES HIGH-EFFICIENCY ITE & MEDICAL SWITCHING POWER SUPPLY

N2POWER XLM500 AC-DC SERIES HIGH-EFFICIENCY ITE & MEDICAL SWITCHING POWER SUPPLY N2POWE XLM500 AC-DC SEIES HIGH-EFFICIENCY ITE & MEDICAL SWITCHING POWE SUPPLY HIGHLIGHTS ITE & Medical switching power supply High efficiency up to 93% P.F.C. function > 0.94 Built-in 12V / 0.3A fan supply

More information

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST LED Driver EUC200SxxxST 20110114 D Features Ultra High Efficiency (Up to ) Active Power Factor Correction (0.99 Typical) Constant Current Output Lightning Protection AllRound Protection: SCP, OTP, OVP

More information

RWS50B RWS100B RWS150B RWS300B RWS600B

RWS50B RWS100B RWS150B RWS300B RWS600B RWS-B Series 50W to 600W Single Output General Purpose Power Supplies Features 10 Year e-cap Lifetime 7 Year Warranty Global Safety Approvals Compact Size Better Field Reliability Lower Cost of Ownership

More information

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

Industrial Power Supplies

Industrial Power Supplies , Features Switch Mode Power Supplies for DIN-rail Mounting 6 Power Ranges with 2, 3, 6, 12, 20 and 24 A Current (24 VDC Models) Selectable 115/ 230 VAC Input Very low Ripple and Noise EMI complies with

More information

N2POWER XLM240 AC-DC SERIES HIGH-EFFICIENCY ITE & MEDICAL SWITCHING POWER SUPPLY

N2POWER XLM240 AC-DC SERIES HIGH-EFFICIENCY ITE & MEDICAL SWITCHING POWER SUPPLY N2POWE XLM240 AC-DC SEIES HIGH-EFFICIENCY ITE & MEDICAL SWITCHING POWE SUPPLY HIGHLIGHTS ITE & Medical switching power supply High efficiency up to 94% P.F.C. function > 0.9 < 0.5W no load input power

More information

Company Overview. Product Offering & Attributes

Company Overview. Product Offering & Attributes Company Overview TDK-Lambda is one of the oldest and most trusted manufacturers of high quality medical power supply solutions. We offer a broad product line with over 5,000 models to choose from. Backed

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2) Features Regulated Converters : Wide input voltage range.6kvdc Isolation UL, IEC/EN69 and EN certified Efficiency up to 88% OVP, OCP & OTP + C max. case temperature Description The RPA-AW series are high

More information

Very high efficiency up to 93% Adjustable output voltage

Very high efficiency up to 93% Adjustable output voltage The Bel Power Solutions 700DNC40-24-xG is a 4 kw DC/DC converter that creates DC voltages in hybrid and electric vehicles necessary to power low voltage accessories. Liquid or convection cooled DC/DC converter

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05

More information

Why Electric Safety Standards

Why Electric Safety Standards Paul Haggarty Why Electric Safety Standards To protect patients and caregivers from electrical shock To prevent electrical interference between instrument sub-systems/circuits To prevent electrical interference

More information

Typical efficiency up to 93 % Up to 4 kw power (max. 16 kw) Liquid or convection cooling. CAN bus serial interface. Adjustable output voltage

Typical efficiency up to 93 % Up to 4 kw power (max. 16 kw) Liquid or convection cooling. CAN bus serial interface. Adjustable output voltage The Bel Power Solutions 350DNC40-12 Series is a 4 kw DC/DC converter that converts HVDC voltages in hybrid and electric vehicles to LVDC voltages suitable to power low voltage (12/24 VDC) accessories.

More information

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters MTC2 Series SELECTION GUIDE FEATURES UL 9 recognised for reinforced insulation ANSI/AAMI ES1-1, 1 MOPP/ 2 MOOPs recognised 3kVAC isolation test voltage Hi Pot Test Continuous short circuit protection Output

More information

$& '& 3RZHU 6XSSOLHV '& '& &RQYHUWHUV %DWWHU\ &KDUJHUV

$& '& 3RZHU 6XSSOLHV '& '& &RQYHUWHUV %DWWHU\ &KDUJHUV www.amtex.com.au About Amtex: Established in 1979 Amtex Electronics is a major supplier & manufacturer of DC Power Supplies. Amtex is a wholly owned Australian company, located in the Sydney suburb of

More information

Switching Power Supplies

Switching Power Supplies , 18 150 Watt Features Compact boxed power supplies with screw terminal block Universal input 85-264 VAC, 50/60 Hz Short circuit and overvoltage protection High efficiency International safety approvals

More information

KEPCO Will Point You In The Right Direction!

KEPCO Will Point You In The Right Direction! Looking For A High Power, Low Profile Power Supply? KEPCO Will Point You In The Right Direction! -9 AN ISO 900 COMPANY You'll Always Find What You Need At Kepco KLN Series Programmable Power Supply: 0W

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

Installation Instructions

Installation Instructions AQU244 & AQU128 Series Installation Instructions Installation Instructions AQU244 24vdc 5A Supervised Power Supply/Charger module AQU128 12vdc 10A Supervised Power Supply/Charger module Both Mounted in

More information

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W peak output power

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W peak output power Silvertel V.3 April 207 Datasheet Pb Features IEEE802.3at and IEEE802.3af compliant Maximum 30W peak output power Small Single In-Line (SIL) package size 57.3mm (L) x 4mm (H) Overload, short-circuit and

More information

Conducted and radiated emissions (Note 4) EN55011, EN55022, Class A and FCC part 18 Immunity (Note 5)

Conducted and radiated emissions (Note 4) EN55011, EN55022, Class A and FCC part 18 Immunity (Note 5) www.emea.tdk-lambda.com/pxc-m Single and Dual Output 3W DC-DC Converters Features 60601-1 approval I/O isolation 5kVAC, 2MOPP 0.25µA low leakage 4:1 Wide input range Benefits Easier system approval Patient

More information

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power Silvertel V1.2 Sept 2014 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2007-01-23 Page 4 of 57 Report Reference # E116994-A34-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL 60601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference

More information

EU RO Mutual Recognition Technical Requirements

EU RO Mutual Recognition Technical Requirements 1. PRODUCT DESCRIPTION... 1 2. DESIGN EVALUATION... 2 3. PRODUCTION REQUIREMENTS... 6 4. MARKING REQUIREMENTS... 6 5. TYPE APPROVAL CERTIFICATE CONTENT... 7 6. APPROVAL DATE AND REVISION NUMBER... 7 7.

More information

Input surge voltage (max 3 seconds) 24V Nom : 50VDC 48V Nom: 100VDC

Input surge voltage (max 3 seconds) 24V Nom : 50VDC 48V Nom: 100VDC www.emea.tdk-lambda.com/pxc-m Single and Dual Output 6W DC-DC Converters Features 60601-1 approval I/O isolation 5kVAC, 2MOPP 0.25µA low patient leakage 4:1 Wide input range Benefits Easier system approval

More information

Presented to the IAPMO Standards Review Committee on December 9, 2013

Presented to the IAPMO Standards Review Committee on December 9, 2013 Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented

More information

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and adaptive technology. This technology is improving

More information

MODEL SELECTION TABLE Open Frame Models. MODEL SELECTION TABLE U-Chassis Models. MODEL SELECTION TABLE Enclosed Models

MODEL SELECTION TABLE Open Frame Models. MODEL SELECTION TABLE U-Chassis Models. MODEL SELECTION TABLE Enclosed Models Open Frame ( O Type) U-Chassis ( U Type) Enclosed ( C Type) DIN Rail Kit ( DN Type) Size: 5in x 3in x 1.16~1.24in (127mm x 76.2mm x 29.5~31.5mm) Size: 5in x 3~3.23in x 1.5in (127mm x 76.2~82.2mm x 38.1mm)

More information

Indoor Linear 50W Driver SI-CU WW

Indoor Linear 50W Driver SI-CU WW Product Data Sheet Rev.2.0 2016. 5. 27 1# LED Driver Indoor Linear 50W Driver SI-CU1425001WW Constant Current LED Driver Features & Benefits Output Current Range: 500~1400 ma (adjustable via R-set) Output

More information

Lighting The Way. Ballast Specification Guide

Lighting The Way. Ballast Specification Guide Lighting The Way To Energy Savings Ballast Specification Guide Ballast Specification Guide Welcome to the American Ballast family of products and services In six short years, American Ballast has built

More information

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power

More information

Three-Phase Soft Starters

Three-Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (+61) 2 4229

More information

Ensuring the Safety Of Medical Electronics

Ensuring the Safety Of Medical Electronics Chroma Systems Solutions, Inc. Ensuring the Safety Of Medical Electronics James Richards, Marketing Engineer Keywords: 19032 Safety Analyzer, Medical Products, Ground Bond/Continuity Testing, Hipot Testing,

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

MGJ1 Series 5.7kVDC Isolated 1W SM Gate Drive DC/DC Converters

MGJ1 Series 5.7kVDC Isolated 1W SM Gate Drive DC/DC Converters www.murata-ps.com MGJ1 Series FEATURES Patent pending Optimised bipolar output voltages for IGBT/ SiC & MOSFET gate drives Reinforced insulation to UL69 recognised ANSI/AAMI ES661-1 recognition pending

More information

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE FEATURES 4:1 Ultra Wide Input Range Output Current up to 2000 ma Miniature SIP (Single-In-Line) Package, 0.86 0.36

More information

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE WATT RAILWAY APPLICATIONS FEATURES No Minimum Load Required 225 Input to Output Basic Insulation Railway Applications 4:1 Wide Input Voltage Range

More information

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power

More information

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V Sorensen XG Series / XTR Series 670 850 W 850 W, 1U Half Rack Programmable DC Power Supplies 6 600 V Highest Power Density Comprehensive Digital and Analog Interface Options Scalable, Multi-Unit Design

More information

GB60S 60W Single Output General Purpose Series

GB60S 60W Single Output General Purpose Series Features 2 x 3 x 1.0 Package Operates to 80 C Ambient For 1U Applications 60W convection cooled Universal Input 90-264Vac Optional Power ON LED Approved to CSA/EN/IEC/UL60950-1, 2 nd Edition Efficiency

More information

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and

More information

Silvertel. Ag9912M Ultra Miniature PoE Module. 1. Features. 2. Description. Tiny SMT package (14mm x 21mm) IEEE802.3af compliant.

Silvertel. Ag9912M Ultra Miniature PoE Module. 1. Features. 2. Description. Tiny SMT package (14mm x 21mm) IEEE802.3af compliant. Silvertel V1.1 September 2016 Datasheet Ultra Miniature PoE Module Pb 1. Features Tiny SMT package (14mm x 21mm) IEEE802.3af compliant Low cost Input voltage range 36V to 57V Minimal external components

More information

Implementing Overtemperature and Overcurrent Protection Matching Today s Higher Current Capacity Lithium-Ion Batteries

Implementing Overtemperature and Overcurrent Protection Matching Today s Higher Current Capacity Lithium-Ion Batteries WHITE PAPER INTRODUCTION Technology advancements have succeeded in lowering the power consumption in electronic components, which has enabled battery suppliers to offer increasingly dense and larger storage

More information

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current SELECTION GUIDE NXE2 Series FEATURES Patents pending Lower Profile UL69 Recognised ANSI/AAMI ES661-1 Recognised 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry

More information

Single & Three-Phase Soft Starters

Single & Three-Phase Soft Starters Submittal Data English Language/IP Units 11/13 Contact Information: Hyper Engineering, Pty. Ltd. 9000 Conservation Way Fort Wayne, IN 46809 www.hypereng.com sales@hypereng.com (877) 304-0724 Model Nomenclature

More information

PG02S Series 2W DC/DC CONVERTER, SIP-Package

PG02S Series 2W DC/DC CONVERTER, SIP-Package PG02S Series 2W DC/DC CONVERTER, SIP-Package FEATURES Efficiency up to 81% SIP Package with Industry Pinout Small Footprint: 21.8 x 9.3 mm (0.86 x 0.37 inch) Wide 2:1 Input Range Operating Temperature

More information

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance

More information

NXE2 Series Isolated 2W Single Output SM DC-DC Converters

NXE2 Series Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE NXE2 Series FEATURES Patents pending Lower Profile UL69 Recognised ANSI/AAMI ES661-1 Recognised 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry

More information

Open Frame Power Supplies

Open Frame Power Supplies , 0 300 Watt Features Small and compact PCB Construction Optional with Chassis and Cover Universal Input 8 264 VAC, Output Voltage adjustable Compliance to E 6000-3-2 (PFC) EMI meets E022, Class B and

More information

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current SELECTION GUIDE FEATURES Patents pending Lower Profile UL9 Recognised ANSI/AAMI ES1-1 Recognised 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry Standard Footprint

More information

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc EUP096SxxxST Features High Efficiency (Up to 93.0%) Full Power at Wide Output Current (Constant Power) Adjustable Output Current (AOC) with Dipswitch Nondimming Control Input Surge Protection: 6kV lineline,

More information

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features: DC/DC Converter 18-36 VDC Input 5.1 VDC Output at 2.4A Features: Applications: Distributed Power Architectures Communications Equipment Computer Equipment Work Stations UL TUV CB CE MARK RoHS Compliant

More information

Optimizing Battery Accuracy for EVs and HEVs

Optimizing Battery Accuracy for EVs and HEVs Optimizing Battery Accuracy for EVs and HEVs Introduction Automotive battery management system (BMS) technology has advanced considerably over the last decade. Today, several multi-cell balancing (MCB)

More information

POWER-WIN TECHNOLOGY CORP.

POWER-WIN TECHNOLOGY CORP. FEATURES Medical 60601-1 3.1 rd Edition approved U-Channel, End fan and Top fan types available Optional high efficiency OR-ing FET diode Current share function 2 year warranty ELECTRICAL SPECIFICATIONS

More information

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012 100V to 1000V DC 100A to 5000A DC SERIES 50 MODELS 506 & 5012 6 Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems Applications: Electrocoating Ion Nitriding Magnet

More information

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen. Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown

More information

Liquid or convection cooled models available CAN bus serial interface

Liquid or convection cooled models available CAN bus serial interface The Bel Power Solutions 700DNC150-56-xG () is a 15000 Watts DC/DC converter that creates DC voltages in hybrid and electric vehicles necessary to power low voltage accessories. Attractive reverse energy

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

Advance Data Sheet: idq Series Filter Module. idq Series Filter Module 75V Input, 10A Output

Advance Data Sheet: idq Series Filter Module. idq Series Filter Module 75V Input, 10A Output idq Series Filter Module 75V Input, 10A Output idq48 filter modules are designed to help reduce differential and common mode conducted emissions from high frequency switching power supplies. The modules

More information

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies D1541 D1542 D1543 D1545 D1543-X-8 D1545-X-8 D1545-4BNC D154X Series 1A 2A 3A 5A 3A fitted with 8-way output splitter

More information

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters www.murata-ps.com MTU1 Series SELECTION GUIDE FEATURES Patent Protected UL60950 recognised Footprint over pins 0.69cm 2 Single & dual isolated output 1kVDC Isolation Hi Pot Test Efficiency up to 88% (Typ.)

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

Digital Power Corporation designs, manufactures, and markets highly efficient, flexible, and custom power supply solutions...

Digital Power Corporation designs, manufactures, and markets highly efficient, flexible, and custom power supply solutions... Digital Power Corporation designs, manufactures, and markets highly efficient, flexible, and custom power supply solutions...... for the medical, military, telecom, and industrial markets. 1 Advanced Custom

More information

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91% Features Regulated Converter Description Sixteenth brick format : input voltage range.kv basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 9% The RPAS is a low cost

More information

Language specific user manuals are available on

Language specific user manuals are available on User Manual WEB Charger for LiFePO 4 Batteries EN User Manual Language specific user manuals are available on www.mascot.no/downloads/usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d

More information

DH50 SERIES. DATASHEET Rev. A

DH50 SERIES. DATASHEET Rev. A DATASHEET DH50 SERIES 2:1 Wide Input Voltage Ranges Single Outputs, Efficiency up to 92% 2.0 x 1.0 x 0.4 Encapsulated Shielded Metal Package FEATURES RoHS & UL 94V-0 Compliant 50 Watts Output Power 2:1

More information

Silvertel. Ag5510. PoE Ultra Module. 1. Features. 2. Description. 60 Watt Output Power. Very small size. High efficiency DC/DC converter

Silvertel. Ag5510. PoE Ultra Module. 1. Features. 2. Description. 60 Watt Output Power. Very small size. High efficiency DC/DC converter V1.1 August 2016 Datasheet Silvertel 1. Features 60 Watt Output Power Very small size High efficiency DC/DC converter Wide adjustable output voltage range 1500V isolation (input to output) Input voltage

More information

DORADO MV DC/DC CONVERTERS 24V Input 12VDC 8A Output

DORADO MV DC/DC CONVERTERS 24V Input 12VDC 8A Output 1/4 Brick Dorado MV Series Industry standard pinout and footprint High efficiency: 86% at 12V, 8A; 88% at 12V, 4A Very low common-mode noise for a commercial DC/DC converter Constant switching frequency

More information

NXJ1 Series Isolated 1W Single Output SM DC-DC Converters

NXJ1 Series Isolated 1W Single Output SM DC-DC Converters SELECTION GUIDE FEATURES Patents pending Lower Profile UL9 Recognised ANSI/AAMI ES-, 2 MOOP, MOPP Recognised 4.2kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry

More information

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%] Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Built-in EMC Filter Ribbed Case Style 22VDC Isolation Wide 4:1 Input Voltage Range EN-522 Class B The

More information

Packaging (1) Package

Packaging (1) Package Features Switching Regulator RoHS / conform (% lead free) High reflow temperature SMD package Adjustable output voltage Short circuit protection, thermal shutdown Remote ON/OFF control very low shutdown

More information

Creating Efficient Solutions for Motor Drive-based Systems CIRCUIT PROTECTION WHITE PAPER

Creating Efficient Solutions for Motor Drive-based Systems CIRCUIT PROTECTION WHITE PAPER Creating Efficient Solutions for Motor Drive-based Systems CIRCUIT PROTECTION WHITE PAPER BACKGROUND More than half of all electrical energy produced is consumed by electric motors, and increasing the

More information

NXJ2 Series Isolated 2W Single Output SM DC-DC Converters

NXJ2 Series Isolated 2W Single Output SM DC-DC Converters NXJ2 Series SELECTION GUIDE FEATURES Patents pending Lower Profile UL69 Recognition pending ANSI/AAMI ES661-1, 2 MOOP, 1MOPP recognition pending 5.2kVDC Isolation Hi Pot Test Substrate Embedded Transformer

More information

Major changes within the New 18 th Edition Wiring Regulations announced by The IET

Major changes within the New 18 th Edition Wiring Regulations announced by The IET Major changes within the New 18 th Edition Wiring Regulations announced by The IET BS 7671:2018 Requirements for Electrical Installations will be issued on 2 nd July 2018 and is intended to come into effect

More information

ZMS100 Series. 80W Convection, 100W Forced-Air Cooled Single Output Power Supplies. ZMS100 Series 1. Specification

ZMS100 Series. 80W Convection, 100W Forced-Air Cooled Single Output Power Supplies. ZMS100 Series 1. Specification ZMS100 Series www.emea.tdk-lambda.com/zms 80W Convection, 100W Forced-Air Cooled Single Output Power Supplies Features Benefits Long e-cap lifetime Better field reliability and service life Compact 2 x

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 7176-21 Second edition 2009-04-01 Wheelchairs Part 21: Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and scooters, and battery

More information

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC stage to convert the 3-phase input

More information

PowerBox C1000 D2R and C1250 D2R. Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments

PowerBox C1000 D2R and C1250 D2R. Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments PowerBox C1000 D2R and C1250 D2R Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments The new PowerBox Built for harsh environments The new PowerBox

More information

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas AS 62040.1.1 2003 IEC 62040-1-1:2002 IEC 62040-1-1:2002/Corr.1:2002 Reconfirmed 2013 AS 62040.1.1 Australian Standard Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION IEC/TS 62257-7-3 TECHNICAL SPECIFICATION Edition 1.0 2008-04 Recommendations for small renewable energy and hybrid systems for rural electrification Part 7-3: Generator set Selection of generator sets

More information

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost Silvertel V2.5 Feb 2014 Datasheet Pb 1 Features IEEE802.3af compliant Small SIL package size - 56mm (L) x 14mm (H) Low cost Input voltage range 36V to 57V Minimal (low cost) external components required

More information

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC stage to convert the 3-phase input

More information

INTELEPOWER CXS SWITCHING SYSTEMS

INTELEPOWER CXS SWITCHING SYSTEMS INTELEPOWER CXS SWITCHING SYSTEMS INTELEPOWER CXS SWITCHING SYSTEMS Intelepower DC UPS - CXS Range Designed For Switching The demands for quality power in switching applications are placing new demands

More information

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF Features Switching Regulator Description Efficiency up tpo 94%, no need for heatsinks Pin-out compatible with LM78XX linears Low profile (L/W/H=11.5 x 7.5 x 1.2mm) Wide input range Short circuit protection,

More information

BATTERY PACK OVERVIEW WHITE PAPER

BATTERY PACK OVERVIEW WHITE PAPER BATTERY PACK OVERVIEW WHITE PAPER BACKGROUND With the exponential growth, increasing complexity and computing power of virtually all electronics applications (particularly portable devices) comes the need

More information

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES DATA DATA SHEET SHEET HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 15 WATT RAILWAY APPLICATIONS FEATURES No Minimum Load Required 225 Input to Output Basic Insulation Railway Applications 4:1

More information

Mil-COTS, Hi-Rel Power Conversion & Battery Management Products

Mil-COTS, Hi-Rel Power Conversion & Battery Management Products Mil-COTS, Hi-Rel Power Conversion & Battery Management Products High Reliability Power About Power-One Power-One is a leading global manufacturer of power conversion and power management solutions, with

More information

AC-DC Converter Application Guidelines

AC-DC Converter Application Guidelines AC-DC Converter Application Guidelines 1. Foreword The following guidelines should be carefully read prior to converter use. Improper use may result in the risk of electric shock, damaging the converter,

More information

Copy of marking plate. Page 2 of 50 Report No. TRS

Copy of marking plate. Page 2 of 50 Report No. TRS Copy of marking plate Page 2 of 50 Report No. TRS09030062 Page 3 of 50 Report No. TRS09030062 GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use... :

More information