Lighting The Way. Ballast Specification Guide

Size: px
Start display at page:

Download "Lighting The Way. Ballast Specification Guide"

Transcription

1 Lighting The Way To Energy Savings Ballast Specification Guide

2 Ballast Specification Guide Welcome to the American Ballast family of products and services In six short years, American Ballast has built an international reputation as an innovative developer and manufacturer of electrical lighting products. You will find our products in numerous business facilities around the world. What makes us unique? American Ballast provides high quality products independently rated at 99.7% reliability small case, at competitive prices. You can count on American Ballast for: Variety we provide a wide array of ballast designs, to meet a variety of lighting needs including standard small case, mini and European-style cans. Quality Control we develop and manufacture all American Ballast products within our own family of engineering labs and manufacturing plants to ensure the highest quality. Customer-oriented developer of custom design products Even with our extensive inventory, a special application may require something more. Our advanced research & development center in Mobile, Alabama can custom design equipment to your specifications, and then manufacture the product at one of our plants. If you can t find the right product to meet your application, call us. We will work with you to create the product you need. Our R&D team develops practical solutions for problems like inrush current levels or electro-magnetic interference and then improves on them. Our commitment to improving performance and saving energy also helps you differentiate your products within your target markets. American Ballast has an accessible management team dedicated to serve you and your customers. We are a large company with a small company approach to customer service. We stand by the quality of our products, all backed by a five-year warranty on materials and workmanship. American Ballast: Dedicated to bringing innovative and energy-saving lighting products to the consumers around the world. American Ballast Phone: Fax: Written by Shirley MacRae

3 TABLE OF CONTENTS Company Profile Lamp Application Matrix Electronic Fluorescent Ballast Products T8 Ballast Highlights... 6 T8 Instant Start Normal, Low & High Output Features & Benefits... 7 T8 Instant Start, High Efficiency Features & Benefits... 8 T8 Programmed Start Features & Benefits... 9 T8 Residential Features & Benefits T8 Lamp Chart T5 Programmed Start Ballast Highlights...18 T5 Programmed Start Features & Benefits T5 Lamp Chart T12 Ballast Highlights T12 Features & Benefits T12 Lamp Chart Energy Policy Act Compact Fluorescent Ballast Highlight Compact Fluorescent Features & Benefits Compact Fluorescent Lamp Chart Ordering Information Cross Reference Glossary of Terms Warranty Information Wiring Diagrams CAN Dimensions Ballast Specification Guide

4 Ballast Specification Guide Company Profile American Ballast offers one of the industry s most comprehensive ranges of high-performance electronic ballasts for commercial and residential lighting applications. The company was established in 2004 specifically to design and manufacture electronic energy-efficient fluorescent and HID ballasts for commercial and residential lighting customers in North America. Offering a broad range of products including T5, T8 and T12, compact and HID solutions American Ballast offers engineering excellence coupled with industry-leading manufacturing capabilities, geared toward producing energy savings while enhancing light levels and quality. The company s energy-efficient fluorescent and HID ballasts meet Energy Star and other industry standards. The company s major development centers in the U.S. and Asia, provide an ideal mix of technological process and designed-in efficiency to ensure value and performance for its customers. Additionally, every manufacturing facility is ISO 9001 and ISO certified. The company s processes and material sourcing are marked by rigorous quality standards that include 100% quality control on incoming components, as well as 100% burn-in, full-functional and advanced-life testing standards. American Ballast and its parent company have been instrumental in the development of many recent efficiency standards relevant to the company s product lines with direct participation in numerous international green committees. American Ballast is part of a $500 million global company, Phihong Technology Co., Ltd., a leader in electronic accessories and power supplies that has been shipping product to North America for more than 35 years. American Ballast benefits from decades of design, manufacturing and sales support excellence of its parent company, which includes the world s fifth-largest power supply manufacturer. Phihong Technology Co., Ltd. and its subsidiaries continually strive to provide the highest quality products and customer support. Phihong has engineering and manufacturing facilities in North and South America, Taiwan and mainland China. With a combined, more than 1.5 million square feet of manufacturing space, Phihong provides world-class quality and global flexibility to serve the expanding needs of its customers. Phihong offers both state-of-the-art surface mount and through-hole-process lines with less than 50ppm defect ratios. Every facility is ISO 9001 and ISO certified. For more information about American Ballast, visit or info@americanballast.com. 2

5 Committed to their customers As a subsidiary of Phihong, American Ballast Corp., measures success by its commitment to customers. Phihong is a global leader in electronic accessories and power supplies, striving for zero defects, on time delivery and support that meets and exceeds its customers expectations. The companies worldwide sales and service organizations have engineering and manufacturing facilities in North and South America, Taiwan and mainland China while providing hub services, application engineering support and local after sales service centers in Europe, Asia and North and South America. Engineering excellence Quality products start with quality engineering. Phihong and its subsidiaries operate major development centers in Silicon Valley, California and Taipei, Taiwan to provide the ideal mix of technological process and designed-in efficiency, ensuring value and performance for their customers. Ballast Specification Guide Manufacturing excellence With more than 700,000 square feet of manufacturing space, Phihong and its subsidiaries facilities in China, Taiwan and Brazil provide world-class quality and global flexibility to serve the expanding needs of its customers. Phihong and its subsidiaries offer both state-of-the-art surface mount and throughhole-process lines with less than 50ppm defect ratios. Every facility is ISO 9001 and ISO certified. Quality and reliability Phihong and its subsidiaries long-term customer relationships have been built through consistently delivering highly reliable products at competitive prices. The drive for quality runs through each aspect of Phihong s organizations. From supplier management, to engineering and manufacturing excellence, to customer-focused service teams Phihong is committed to delivering the best. 3

6 Ballast Specification Guide 4 T8 lamp application matrix T12 T8 T8 U T5 T12HO T5 HO T5C AB1-32-IP Lamp 17/25/30/32W 1 Lamp 16/24/31/32W AB2-32-IP Lamp 40, 2/1 Lamp 17/25/30/32W 2/1 Lamp 16/24/31/32W AB3-32-IP Lamp 40, 3/2 Lamp 17/25/30/32W 3/2 Lamp 16/24/31/32W AB4-32-IP Lamp 40, 4/3 Lamp 17/25/30/32W 4/3 Lamp 16/24/31/32W AB1-32-IP Lamp 17/25/30/32W 1 Lamp 16/24/31/32W AB2-32-IP Lamp 40, 2/1 Lamp 17/25/30/32W 2/1 Lamp 16/24/31/32W AB3-32-IP Lamp 40, 3/2 Lamp 17/25/30/32W 3/2 Lamp 16/24/31/32W AB4-32-IP Lamp 40, 4/3 Lamp 17/25/30/32W 4/3 Lamp 16/24/31/32W AB1-32-IP-UNV 1 Lamp 17/25/30/32W 1 Lamp 16/24/31/32W AB2-32-IP-UNV 1 Lamp 40, 2/1 Lamp 17/25/30/32W 2/1 Lamp 16/24/31/32W AB3-32-IP-UNV 2 Lamp 40, 3/2 Lamp 17/25/30/32W 3/2 Lamp 16/24/31/32W AB4-32-IP-UNV 3 Lamp 40, 4/3 Lamp 17/25/30/32W 4/3 Lamp 16/24/31/32W AB1-32-IP-120-HE 1 Lamp 17/25/28/32W 1 Lamp 17/25/28/32W AB2-32-IP-120-HE 1 Lamp 40, 2/1 Lamp 17/25/28/32W 2/1 Lamp 17/25/28/32W AB3-32-IP-120-HE 2 Lamp 40, 3/2 Lamp 17/25/28/32W 2/1 Lamp 17/25/28/32W AB4-32-IP-120-HE 3 Lamp 40, 4/3 Lamp 17/25/28/32W 2/1 Lamp 17/25/28/32W AB1-32-PS-UNV AB2-32-PS-UNV AB3-32-PS-UNV AB4-32-PS-UNV AB2-32-IP-120-R AB4-32-IP-120-R AB2-59-IP-UNV T5 AB2-40-PS-UNV-BX AB2-28-PS-UNV 1 lamp 17/24/25/31/32W 1 Lamp 40, 2/1 Lamp 17/24/25/31/32W 2 Lamp 40, 3/2 Lamp 17/24/25/31/32W 3 Lamp 40, 4/3 Lamp 17/24/25/31/32W 2/1 lamp 32/31/25/24/17/40/34W 4/3 lamp 32/31/25/24/17/40/34W 2/1 Lamp 59W/F96T8 AB2-54-PS-UNV AB4-54-PS-UNV 4 Foot T12 AB1-40-RS lamp 40/34W AB1-40-RS lamp 40/34W AB2-40-RS-120 2/1 lamp 40/34W 2 F32T8 AB2-40-RS-277 2/1 lamp 40/34W 2 F32T8 AB2-40-RS-120-R 2/1 lamp 40/34W 2 F32T8 8 Foot T12 AB2-96-IP-120 2/1 lamp 96/84/72/64/60/48 AB2-96HO-RS-120 AB2-96-IP-277 2/1 lamp 96/84/72/64/60/48 AB2-96HO-RS-277 AB2-96HO-RS-UNV 2/1 Lamp 14/21/28W 2/1 HO lamp 96//84/72/60/48W 2/1 HO lamp 96//84/72/60/48W 2/1 HO lamp 96//84/72/60/48W 2/1 Lamp 54W 4/3 Lamp 54W Compacts AB2-13-PS-UNV AB2-18-PS-UNV AB2-26-PS-UNV 1/22/40W AB2-42-PS-UNV 1/22W + 1/40W

7 FT CFQ CFTR CFM CFS T8 AB1-32-IP Lamp 18/24/27/36/39/40W AB2-32-IP Lamp 18/24/27/36/39/40W AB3-32-IP Lamp 18/24/27/36/39/40W AB4-32-IP-120 AB1-32-IP-277 AB2-32-IP Lamp 18/24/27/36/39/40W AB3-32-IP Lamp 18/24/27/36/39/40W AB4-32-IP Lamp 18/24/27/36/39/40W AB1-32-IP-UNV AB2-32-IP-UNV 1 Lamp 18/24/27/36/39/40W AB3-32-IP-UNV 2 Lamp 18/24/27/36/39/40W AB4-32-IP-UNV 3 Lamp 18/24/27/36/39/40W AB1-32-IP-120-HE AB2-32-IP-120-HE AB3-32-IP-120-HE AB4-32-IP-120-HE AB1-32-PS-UNV AB2-32-PS-UNV AB3-32-PS-UNV AB4-32-PS-UNV AB2-32-IP-120-R AB4-32-IP-120-R AB2-59-IP-UNV T5 AB2-40-PS-UNV-BX 2/1 Lamp 39/40W AB2-28-PS-UNV Ballast Specification Guide AB2-54-PS-UNV 2/1 Lamp 50/55W AB4-54-PS-UNV 4/3 Lamp 50/55W 4 Foot T12 AB1-40-RS-120 2/1 Lamp 13W 2/1 Lamp 10/16W AB1-40-RS-277 2/1 Lamp 18W 2/1 Lamp 18W 2/1 Lamp 21W AB2-40-RS Lamp 24/27/40W 2/1 Lamp 26W 2 Lamp 26W or 1 Lamp 32,42W 1/28/38W AB2-40-RS Lamp 24/27/40W 2/1 Lamp 26W 2/1 Lamp 26,32,42W 2 Lamp 28/38 AB2-40-RS-120-R 8 Foot T12 AB2-96-IP-120 AB2-96HO-RS-120 AB2-96-IP-277 AB2-96HO-RS-277 AB2-96HO-RS-UNV Compacts AB2-13-PS-UNV 2/1 Lamp 13W 2/1 Lamp 10/16W AB2-18-PS-UNV 2/1 Lamp 18W 2/1 Lamp 18W 2/1 Lamp 21W AB2-26-PS-UNV 1 Lamp 24/27/40W 2/1 Lamp 26W 2 Lamp 26W or 1 Lamp 32,42W 1/28/38W AB2-42-PS-UNV 2 Lamp 24/27/40W 2/1 Lamp 26W 2/1 Lamp 26,32,42W 2 Lamp 28/38 5

8 Ballast Specification Guide 6 T8 Dedicated & Universal Voltage Instant/Programmed Start Ballast Models Include: Dedicated & Universal Voltage LX Low Light Output HX High Light Output Programmed Start Ballast Highlights: Instant Start HE High Efficiency R Residential UNV Universal-Voltage Performance All ballasts (1-, 2-, 3- and 4-lamp models) are designed with parallel circuitry to enable the remaining lamps to maintain full light output if one or more lamps fail to operate. (Does not include Program Start Mode - series circuitry). Ballasts shall operate from a 60Hz input source (120 to 277V), and sustain voltage variations of ±10%. UNV Model ballasts shall operate at either 50 or 60Hz input sources (108 to 305V), and sustain voltage variations of ±10%. Ballasts are high frequency, electronic-type models that operate lamps at a frequency higher than 20kHz. UNV models operate lamps at a frequency between khz or greater to avoid interference with infrared devices. Lamp current crest factor (peak lamp current/average lamp current) shall be 1.7 or less in accordance with lamp manufacturer recommendation ANSI C Ballasts shall operate in ambient temperatures up to 40 C and ballast case temperatures up to 90 C without damage. Ballasts shall comply with FCC Part 18, Class A (non-consumer) regulations for EMI levels (conducted and radiated). Ballasts shall provide transient immunity as recommended under ANSI C Ballasts shall be UL Listed (UL 935), Class P, Type 1 Outdoor and CSAcertified as required. Ballasts shall operate lamps at less than 3% flicker index (virtually nonvisible flicker). Normal light output ballasts shall exhibit a ballast factor greater than.85 (ANSI C ); Low light output ballasts (LX) shall exhibit a ballast factor greater than.76; and High light output ballasts (HX) shall exhibit a ballast factor of Total Harmonic Distortion (THD) shall not exceed 20% for primary lamp applications. UNV Model ballasts shall not exceed 10% THD for primary lamp applications. Residential (R Model) shall not exceed 200% THD. Ballasts shall have a Power Factor (ratio between real power and apparent power) greater than.98 for primary lamp applications. Residential (R Model) shall have a Power Factor greater than.50. Ballasts shall not contain PCBs (polychlorinated biphenyls). Ballasts shall have a Class A sound rating. Ballasts shall be manufactured in an ISO 9001-certified facility. Ballasts shall be provided with lead wires, color-coded in accordance with ANSI C82.11 standards. Ballasts shall be potted and are contained within a metal enclosure for optimum thermal performance. Ballasts shall be either remote- or tandem-wired up to a maximum of 18 feet overall lead length, measured from ballast to lamps. (Consult American Ballast engineering department for specific applications). American Ballast shall provide written warranty against defects in material or workmanship, including replacement for a period of five years from date of manufacture; residential for a period of two years.

9 T8 INSTANT START - NORMAL LIGHT OUTPUT - LOW LIGHT OUTPUT - HIGH LIGHT OUTPUT 120 /277 Voltages - Universal Voltage One ballast operates multiple lamp types Applications: New Construction and Retrofit Installations Board and Meeting Rooms Conference Rooms General Office Lighting Features and Benefits: Dedicated voltage 120 / 277V (60Hz) Universal input voltage ( volts, 50/60 Hz) - Installer-friendly ensures you have the right ballast every time - Reduces inventory costs and requirements - Ideal for international markets with multiple voltages Smaller case size - Optimizes luminaires for T8 lamp size and optics Ideal for thin profile fixtures Lighter weight - Easier to install - Less shipping cost - Ideal for suspended fixtures Standard mounting footprint and wiring for easy replacement - Fits all standard T12 and T8 fixtures Parallel lamp operation keeps other lamps functioning when one lamp fails Instant Start operation for maximum energy savings Full product family of 1 4 lamp 4-foot T8 models available 2-lamp T8 model for 8-foot applications Manufactured with surface mount technology components for enhanced reliability Total Harmonic Distortion < 10% Minimum start temperature: 0 F / -18 F Sound rating: Class A Complies with the limits of FCC Part 18C for non-consumer equipment Meets all ANSI requirements to assure proper lamp and ballast performance Normal Light Output Ballast Factor -.88 Low Light Output Ballast Factor -.78 Executive Offices Hospitals Schools Department Stores High Light Output Ballast Factor UL and CuL Listed Applicable models meet Energy Star requirements Ballast Specification Guide 7

10 Ballast Specification Guide T8 Instant Start - Universal Voltage High Efficiency NEMA Premium Ballast Ballast Models Include: Features and Benefits: High Efficiency: Ballast Factor -.88 Universal input voltage of 108 to 305 volts (50/60 Hz) - Installer-friendly ensures you have the right ballast every time - Reduces inventory costs and requirements - Ideal for international markets with multiple voltages Multiple lamp application - F32T8, F32T8ES, (30W, 28W, 25W), F25T8, F17T8 Parallel lamp operation keeps other lamps functioning when one lamp fails Auto-restrike as a standard feature Designed for maximum efficiency Total Harmonic Distortion < 10% Minimum start temperature: 0 F / -18 F Anti-Striation circuitry for energy saving lamps Meets NEMA and CEE High Efficiency T8 ballast specifications Sound rating: Class A Comply with the limits of FCC Part 18C for non-consumer equipment Low profile Standard mounting footprint and wiring for easy replacement Remote mounting up to 20 feet Tandem wiring up to 20 feet UL and CuL Listed The National Electrical Manufacturers Association established the NEMA Premium Ballast Program in accordance with standards established by the Consortium for Energy Efficiency (CEE). American Ballast is among the members of the ballast program offering products that represent the best energy-saving products. Applications: General Lighting Decorative Lighting Retail Lighting Indirect Lighting Occupancy Sensor Applications New Construction and Retrofit Installations 8

11 T8 Programmed Start - Universal Voltage One ballast operates multiple lamp types Applications: New Construction and Retrofit Installations Frequent On/Off Switching or Occupancy Sensor Controlled Spaces Features and Benefits: Programmed Rapid Start Operation Universal input voltage ( volts, 50/60 Hz) Installer-friendly you have the right voltage ballast for all jobs Reduces inventory costs and requirements Ideal for international markets with multiple voltages Smaller case size Optimizes luminaires for T8 lamp size and optics Ideal for thin profile fixtures Lighter weight - Easier to install - Less shipping cost - Ideal for suspended fixtures Maximizes lamp life provides up to 30,000 lamp cycles Reduced lamp replacement Ideal for use with occupancy sensors Standard mounting footprint and wiring for easy replacement Improved occupant safety when one lamp fails on one circuit, lamps on parallel circuit stay on Cost effective replace only the lamps that have failed without having to troubleshoot other lamp Capable of remote/tandem applications up to 20 feet One ballast can be used to operate two fixtures Manufactured using Surface Mount Technology for enhanced reliability THD < 10% Minimum Start Temperature: 0 F/-18 F Sound Rating: Class A Comply with the limits of FCC Part 18C for Non-Consumer equipment Meets all ANSI requirements to assure proper lamp and ballast performance General Office Lighting Boardrooms and Executive Offices Conference and Meeting Rooms UL and CuL Listed Applicable models meet Energy Star requirements Ballast Specification Guide 9

12 Ballast Specification Guide T8 RESIDENTIAL - 120V One ballast operates multiple lamp types Features and Benefits: High operating efficiency meets Energy Star requirements The family includes two models that operate one to four F32T8 lamps; 60Hz - Promotes flexibility in fixture designs - Instant-Start circuitry - Provides instant light Provides a low cost, economical ballast for residential applications Total Harmonic Distortion < 200% Meets Class P, Type 1 Outdoor standard ANSI rated full (.88 Ballast Factor) light output for F32T8 lamps Reliable starting at temperatures down to 0 F - Great for garage installations in most regions Instant Start technology for quick lamp strike Parallel lamp operation keeps other lamps functioning when one lamp fails Small dimensions and light weight for fixture design flexibility Fully complies with FCC consumer regulations for residential applications Sound rating: Class A ensures quiet operation Comply with the limits of FCC Part 18C consumer (Class B) UL and CuL Listed Applications: Lighting brings life into the house; it warms, brightens and enhances your home. If it is well thought out and carefully selected, it is a real bonus to comfort. Hallways Living Rooms Dining Rooms Kitchens Master Bedrooms Children s Rooms Bathrooms Home Offices 10

13 ELECTRONIC BALLASTS: T8 LAMPS LAMP APPLICATIONS: F32T8 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F32T8 HIGH 32 1 AB1-32-IP-UNV-HE % 91% F <10% H A EFFICIENCY 32 1 AB1-32-IP-UNV-HE % 91% F <10% H A 32 1 AB2-32-IP-UNV-HE % 105% F <10% H U 32 1 AB2-32-IP-UNV-HE % 105% F <10% H U STANDARD 32 1 AB1-32-IP % 87% F <20% A A 32 1 AB1-32-IP % 87% F <20% A A 32 1 AB1-32-IP-UNV % 88% F <10% A A 32 1 AB1-32-IP-UNV % 88% F <10% A A 32 1 AB2-32-IP % 105% F <20% A U 32 1 AB2-32-IP % 105% F <25% A U RESIDENTIAL 32 1 AB2-32-IP-120-R >50% 100% F <150% H U 32 1 AB2-40-RS-120-R % 105% F <150% A H PROGRAM 32 1 AB2-32-PS-UNV % 89% F <10% A H START 32 1 AB2-32-PS-UNV % 89% F <10% A H LOW 32 1 AB2-32-IP-UNV-LX % 97% F <10% H U 32 1 AB2-32-IP-UNV-LX % 97% F <10% H U HIGH 32 1 AB2-32-IP-UNV-HX % 141% F <10% A U 32 1 AB2-32-IP-UNV-HX % 141% F <10% A U HIGH 32 2 AB2-32-IP-UNV-HE % 89% F <10% H B EFFICIENCY 32 2 AB2-32-IP-UNV-HE % 89% F <10% H B 32 2 AB3-32-IP-UNV-HE % 99% F <10% A V 32 2 AB3-32-IP-UNV-HE % 99% F <10% A V STANDARD 32 2 AB2-32-IP-UNV % 88% F <10% A B 32 2 AB2-32-IP-UNV % 88% F <10% A B 32 2 AB2-32-IP % 88% F <20% A B 32 2 AB2-40-RS % 125% F <20% A F 32 2 AB2-32-IP % 88% F <20% A B 32 2 AB3-32-IP-UNV % 102% F <10% A V 32 2 AB3-32-IP-UNV % 102% F <10% A V 32 2 AB3-32-IP % 102% F <20% A V 32 2 AB3-32-IP % 102% F <20% A V RESIDENTIAL 32 2 AB2-32-IP-120-R >50% 85% F <135% H B 32 2 AB2-40-RS-120-R % 84% F <120% A F PROGRAM 32 2 AB2-32-PS-UNV % 87% F <10% A F START 32 2 AB2-32-PS-UNV % 87% F <10% A F LOW 32 2 AB2-32-IP-UNV-LX % 77% F <20% H B 32 2 AB2-32-IP-UNV-LX % 77% F <20% H B 32 2 AB3-32-IP-UNV-LX % 91% F <20% A V 32 2 AB3-32-IP-UNV-LX % 91% F <20% A V HIGH 32 2 AB2-32-IP-UNV-HX % 130% F <10% A B 32 2 AB2-32-IP-UNV-HX % 130% F <10% A B 32 2 AB3-32-IP-UNV-HX % 104% F <10% A V 32 2 AB3-32-IP-UNV-HX % 104% F <10% A V HIGH 32 3 AB3-32-IP-UNV-HE % 88% F <10% A C EFFICIENCY 32 3 AB3-32-IP-UNV-HE % 88% F <10% A C 32 3 AB4-32-IP-UNV-HE % 97% F <10% A W 32 3 AB4-32-IP-UNV-HE % 97% F <10% A W STANDARD 32 3 AB3-32-IP-UNV % 88% F <10% A C 32 3 AB3-32-IP-UNV % 88% F <10% A C Ballast Specification Guide 11

14 Ballast Specification Guide ELECTRONIC BALLASTS: T8 LAMPS LAMP APPLICATIONS: F32T8, F32T8/ES(25W/28W/30W) PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F32T8 STANDARD 32 3 AB3-32-IP-UNV % 88% F <10% A C 32 3 AB3-32-IP-UNV % 88% F <10% A C 32 3 AB3-32-IP % 88% F <20% A C 32 3 AB3-32-IP % 88% F <20% A C 32 3 AB4-32-IP-UNV % 93% F <10% A W 32 3 AB4-32-IP-UNV % 93% F <10% A W 32 3 AB4-32-IP % 102% F <20% A W 32 3 AB4-32-IP % 102% F <20% A W RESIDENTIAL 32 3 AB4-32-IP-120-R >50% 92% F <200% A W 30 3 AB4-32-IP-120-R >50% 92% F <200% A W PROGRAM 32 3 AB4-32-PS-UNV % 93% F <10% A Q START 32 3 AB4-32-PS-UNV % 93% F <10% A Q LOW 32 3 AB3-32-IP-UNV-LX % 77% F <20% A C 32 3 AB3-32-IP-UNV-LX % 77% F <20% A C 32 3 AB4-32-IP-UNV-LX % 85% F <20% A W 32 3 AB4-32-IP-UNV-LX % 85% F <20% A W HIGH 32 3 AB3-32-IP-UNV-HX % 88% F <10% A C 32 3 AB3-32-IP-UNV-HX % 88% F <10% A C 30 3 AB3-32-IP-UNV-HX % 87% F <10% A C 30 3 AB3-32-IP-UNV-HX % 87% F <10% A C HIGH 32 4 AB4-32-IP-UNV-HE % 88% F <10% A D EFFICIENCY 32 4 AB4-32-IP-UNV-HE % 88% F <10% A D STANDARD 32 4 AB4-32-IP-UNV % 88% F <10% A D 32 4 AB4-32-IP-UNV % 88% F <10% A D 32 4 AB4-32-IP % 87% F <20% A D 32 4 AB4-32-IP % 87% F <20% A D RESIDENTIAL 32 4 AB4-32-IP-120-R >50% 84% F <150% A D PROGRAM 32 4 AB4-32-PS-UNV % 88% F <10% A QQ START 32 4 AB4-32-PS-UNV % 88% F <10% A QQ LOW 32 4 AB4-32-IP-UNV-LX % 77% F <20% A D 32 4 AB4-32-IP-UNV-LX % 77% F <20% A D HIGH 32 2 AB2-32-IP-UNV-HE % 89% F <10% H B EFFICIENCY 32 2 AB2-32-IP-UNV-HE % 89% F <10% H B F30T8 HIGH 30 1 AB1-32-IP-UNV-HE % 91% F <10% H A EFFICIENCY 30 1 AB1-32-IP-UNV-HE % 91% F <10% H A 30 1 AB2-32-IP-UNV-HE % 104% F <10% H U 30 1 AB2-32-IP-UNV-HE % 104% F <10% H STANDARD 30 1 AB1-32-IP % 87% F <20% A A 30 1 AB1-32-IP % 87% F <20% A A 30 1 AB1-32-IP-UNV % 87% F <10% H A 30 1 AB1-32-IP-UNV % 87% F <10% H A 30 1 AB2-32-IP % 105% F <20% A U 30 1 AB2-32-IP % 105% F <25% A U RESIDENTIAL 30 1 AB2-32-IP-120-R >50% 102% F <150% H U 30 1 AB2-40-RS-120-R >50% 106% F <150% A H PROGRAM 30 1 AB2-32-PS-UNV % 89% F <10% A H START 30 1 AB2-32-PS-UNV % 89% F <10% A H LOW 30 1 AB2-32-IP-UNV-LX % 93% F <10% H U 30 1 AB2-32-IP-UNV-LX % 93% F <10% H U HIGH 30 1 AB2-32-IP-UNV-HX % 141% F <10% A U 30 1 AB2-32-IP-UNV-HX % 141% F <10% A U 12

15 ELECTRONIC BALLASTS: T8 LAMPS 32/ES LAMP APPLICATIONS: F32T8, F32T8/ES(25W/28W/30W), FB031T8 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F30T8 HIGH 30 2 AB2-32-IP-UNV-HE % 89% F <10% H B EFFICIENCY 30 2 AB2-32-IP-UNV-HE % 89% F <10% H B 30 2 AB3-32-IP-UNV-HE % 104% F <10% A V 30 2 AB3-32-IP-UNV-HE % 104% F <10% A V STANDARD 30 2 AB2-32-IP-UNV % 88% F <10% A B 30 2 AB2-32-IP-UNV % 88% F <10% A B 30 2 AB2-32-IP % 87% F <20% A B 30 2 AB2-40-RS % 125% F <20% A F 30 2 AB2-32-IP % 88% F <20% A B 30 2 AB3-32-IP-UNV % 103% F <10% A V 30 2 AB3-32-IP-UNV % 103% F <10% A V 30 2 AB3-32-IP % 103% F <20% A V 30 2 AB3-32-IP % 103% F <20% A V RESIDENTIAL 30 2 AB2-32-IP-120-R >50% 85% F <135% H B 30 2 AB2-40-RS-120-R % 85% F <120% A F PROGRAM 30 2 AB2-32-PS-UNV % 87% F <10% A F START 30 2 AB2-32-PS-UNV % 87% F <10% A F LOW 30 2 AB2-32-IP-UNV-LX % 75% F <20% H B 30 2 AB2-32-IP-UNV-LX % 75% F <20% H B 30 2 AB3-32-IP-UNV-LX % 87% F <20% A V 30 2 AB3-32-IP-UNV-LX % 87% F <20% A V HIGH 30 2 AB2-32-IP-UNV-HX % 130% F <10% A B 30 2 AB2-32-IP-UNV-HX % 130% F <10% A B 30 2 AB3-32-IP-UNV-HX % 104% F <10% A V 30 2 AB3-32-IP-UNV-HX % 104% F <10% A V HIGH 30 3 AB3-32-IP-UNV-HE % 88% F <10% A C EFFICIENCY 30 3 AB3-32-IP-UNV-HE % 88% F <10% A C 30 3 AB4-32-IP-UNV-HE % 97% F <10% A W 30 3 AB4-32-IP-UNV-HE % 97% F <10% A W STANDARD 30 3 AB3-32-IP-UNV % 89% F <10% A C 30 3 AB3-32-IP-UNV % 89% F <10% A C 30 3 AB3-32-IP % 89% F <20% A C 30 3 AB3-32-IP % 89% F <20% A C 30 3 AB4-32-IP-UNV % 103% F <10% A W 30 3 AB4-32-IP-UNV % 103% F <10% A W 30 3 AB4-32-IP % 103% F <20% A W 30 3 AB4-32-IP % 103% F <20% A W RESIDENTIAL 30 3 AB4-32-IP-120-R >50% 92% F <200% A W PROGRAM 30 3 AB4-32-PS-UNV % 93% F <10% A QQ START 30 3 AB4-32-PS-UNV % 93% F <10% A QQ LOW 30 3 AB3-32-IP-UNV-LX % 75% F <20% A C 30 3 AB3-32-IP-UNV-LX % 75% F <20% A C 30 3 AB4-32-IP-UNV-LX % 81% F <20% A W 30 3 AB4-32-IP-UNV-LX % 81% F <20% A W HIGH 30 3 AB3-32-IP-UNV-HX % 87% F <10% A C 30 3 AB3-32-IP-UNV-HX % 87% F <10% A C HIGH 30 4 AB4-32-IP-UNV-HE % 88% F <10% A D EFFICIENCY 30 4 AB4-32-IP-UNV-HE % 88% F <10% A D STANDARD 30 4 AB4-32-IP-UNV % 88% F <10% A D 30 4 AB4-32-IP-UNV % 88% F <10% A D 30 4 AB4-32-IP % 88% F <20% A D 30 4 AB4-32-IP % 88% F <20% A D RESIDENTIAL 30 4 AB4-32-IP-120-R >50% 84% F <150% A D PROGRAM 30 4 AB4-32-PS-UNV % 88% F <10% A QQ START 30 4 AB4-32-PS-UNV % 88% F <10% A QQ LOW 30 4 AB4-32-IP-UNV-LX % 75% F <20% A D 30 4 AB4-32-IP-UNV-LX % 75% F <20% A D Ballast Specification Guide 13

16 Ballast Specification Guide ELECTRONIC BALLASTS: T8 LAMPS 32/ES LAMP APPLICATIONS: F28T8 & F25T8 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F28T8 HIGH 28 1 AB1-32-IP-UNV-HE % 91% F <10% H A EFFICIENCY 28 1 AB1-32-IP-UNV-HE % 91% F <10% H A 28 1 AB2-32-IP-UNV-HE % 104% F <10% H U 28 1 AB2-32-IP-UNV-HE % 104% F <10% H U 28 2 AB2-32-IP-UNV-HE % 89% F <10% H B 28 2 AB2-32-IP-UNV-HE % 89% F <10% H B 28 2 AB3-32-IP-UNV-HE % 104% F <10% A V 28 2 AB3-32-IP-UNV-HE % 104% F <10% A V 28 3 AB3-32-IP-UNV-HE % 88% F <10% A C 28 3 AB3-32-IP-UNV-HE % 88% F <10% A C 28 3 AB4-32-IP-UNV-HE % 98% F <10% A W 28 3 AB4-32-IP-UNV-HE % 98% F <10% A W 28 4 AB4-32-IP-UNV-HE % 88% F <10% A D 28 4 AB4-32-IP-UNV-HE % 88% F <10% A D PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F25T8 HIGH 25 1 AB1-32-IP-UNV-HE % 91% F <10% H A EFFICIENCY 25 1 AB1-32-IP-UNV-HE % 91% F <10% H A 25 1 AB2-32-IP-UNV-HE % 104% F <20% H U 25 1 AB2-32-IP-UNV-HE % 104% F <20% H U 25 2 AB2-32-IP-UNV-HE % 89% F <10% H B 25 2 AB2-32-IP-UNV-HE % 89% F <10% H B 25 2 AB3-32-IP-UNV-HE % 104% F <20% A V 25 2 AB3-32-IP-UNV-HE % 104% F <20% A V 25 3 AB3-32-IP-UNV-HE % 88% F <10% A C 25 3 AB3-32-IP-UNV-HE % 88% F <10% A C 25 3 AB4-32-IP-UNV-HE % 98% F <10% A W 25 3 AB4-32-IP-UNV-HE % 98% F <10% A W 25 4 AB4-32-IP-UNV-HE % 88% F <10% A D 25 4 AB4-32-IP-UNV-HE % 88% F <10% A D 14

17 ELECTRONIC BALLASTS: T8 LAMPS LAMP APPLICATIONS: F32T8, F32T8/ES(25W/28W/30W), F25T8 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F25T8 STANDARD 25 1 AB1-32-IP % 90% F <20% A A 25 1 AB1-32-IP % 90% F <20% A A 25 1 AB1-32-IP-UNV % 90% F <10% A A 25 1 AB1-32-IP-UNV % 90% F <10% A A 25 1 AB2-32-IP-UNV % 103% F <20% A U 25 1 AB2-32-IP-UNV % 103% F <20% A U 25 1 AB2-32-IP % 103% F <30% A U 25 1 AB2-32-IP % 112% F <30% A U RESIDENTIAL 25 1 AB2-32-IP-120-R >50% 105% F <200% H U PROGRAM 25 1 AB2-32-PS-UNV % 89% /-18 F <15% A H START 25 1 AB2-32-PS-UNV % 89% /-18 F <15% A H LOW 25 1 AB2-32-IP-UNV-LX % 100% F <20% H U 25 1 AB2-32-IP-UNV-LX % 100% F <20% H U HIGH 25 1 AB2-32-IP-UNV-HX % 130% F <10% A U 25 1 AB2-32-IP-UNV-HX % 130% F <10% A U HIGH 25 2 AB2-32-IP-UNV-HE % 90% F <20% H B EFFICIENCY 25 2 AB2-32-IP-UNV-HE % 90% F <20% H B 25 2 AB3-32-IP-UNV-HE % 105% F <20% A V 25 2 AB3-32-IP-UNV-HE % 105% F <20% A V STANDARD 25 2 AB2-32-IP-UNV % 88% F <10% A B 25 2 AB2-32-IP-UNV % 88% F <10% A B 25 2 AB2-32-IP % 90% F <20% A B 25 2 AB2-32-IP % 88% F <20% A B 25 2 AB3-32-IP-UNV % 103% F <20% A V 25 2 AB3-32-IP-UNV % 103% F <20% A V 25 2 AB3-32-IP % 103% F <20% A V 25 2 AB3-32-IP % 103% F <20% A V RESIDENTIAL 25 2 AB2-32-IP-120-R % 86% F <150% H B PROGRAM 25 2 AB2-32-PS-UNV % 88% F <10% A F START 25 2 AB2-32-PS-UNV % 88% F <10% A F LOW 25 2 AB2-32-IP-UNV-LX % 77% F <20% H B 25 2 AB2-32-IP-UNV-LX % 77% F <20% H B 25 2 AB3-32-IP-UNV-LX % 96% F <20% A V 25 2 AB3-32-IP-UNV-LX % 96% F <20% A V HIGH 25 2 AB2-32-IP-UNV-HX % 110% F <10% A B 25 2 AB2-32-IP-UNV-HX % 110% F <10% A B 25 2 AB3-32-IP-UNV-HX % 140% F <10% A V 25 2 AB3-32-IP-UNV-HX ` 96% 140% F <10% A V HIGH 25 3 AB3-32-IP-UNV-HE % 88% F <20% A C EFFICIENCY 25 3 AB3-32-IP-UNV-HE % 88% F <20% A C 25 3 AB4-32-IP-UNV-HE % 98% F <20% A W 25 3 AB4-32-IP-UNV-HE % 98% F <20% A W STANDARD 25 3 AB3-32-IP-UNV % 88% F <10% A C 25 3 AB3-32-IP-UNV % 88% F <10% A C 25 3 AB3-32-IP % 88% F <20% A C 25 3 AB3-32-IP % 88% F <20% A C 25 3 AB4-32-IP-UNV % 103% F <20% A W 25 3 AB4-32-IP-UNV % 103% F <20% A W 25 3 AB4-32-IP % 103% F <20% A W 25 3 AB4-32-IP % 103% F <20% A W RESIDENTIAL 25 3 AB4-32-IP-120-R % 88% F <200% A W PROGRAM 25 3 AB4-32-PS-UNV % 94% F <20% A QQ START 25 3 AB4-32-PS-UNV % 94% F <20% A QQ LOW 25 3 AB3-32-IP-UNV-LX % 82% F <20% A C 25 3 AB3-32-IP-UNV-LX % 82% F <20% A C 25 3 AB4-32-IP-UNV-LX % 85% F <20% A W 25 3 AB4-32-IP-UNV-LX % 85% F <20% A W HIGH 25 3 AB3-32-IP-UNV-HX % 116% F <10% A C 25 3 AB3-32-IP-UNV-HX % 116% F <10% A C HIGH 25 4 AB4-32-IP-UNV-HE % 89% F <10% A D EFFICIENCY 25 4 AB4-32-IP-UNV-HE % 89% F <10% A D Ballast Specification Guide 15

18 Ballast Specification Guide ELECTRONIC BALLASTS: T8 LAMPS LAMP APPLICATIONS: F25T8, F17T8 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F25T8 STANDARD 25 4 AB4-32-IP-UNV % 88% F <10% A D 25 4 AB4-32-IP-UNV % 88% F <10% A D 25 4 AB4-32-IP % 88% F <20% A D 25 4 AB4-32-IP % 88% F <20% A D RESIDENTIAL 25 4 AB4-32-IP-120-R % 82% F <200% A D PROGRAM 25 4 AB4-32-PS-UNV % 89% F <10% A QQ START 25 4 AB4-32-PS-UNV % 89% F <10% A QQ LOW 25 4 AB4-32-IP-UNV-LX % 82% F <20% A D 25 4 AB4-32-IP-UNV-LX % 82% F <20% A D F17T8 RESIDENTIAL 25 1 AB2-32-IP-120-R % 106% F <200% H U 25 2 AB2-32-IP-120-R % 87% F <200% H B 25 3 AB4-32-IP-120-R % 88% F <200% A W 25 4 AB4-32-IP-120-R % 82% F <200% A D PROGRAM 25 1 AB2-32-PS-UNV % 89% F <15% A H START 25 2 AB2-32-PS-UNV % 88% F <10% A F 25 3 AB4-32-PS-UNV % 94% F <10% A QQ 25 4 AB4-32-PS-UNV % 89% F <10% A QQ 25 1 AB2-32-PS-UNV % 89% F <15% A H 25 2 AB2-32-PS-UNV % 88% F <10% A F 25 3 AB4-32-PS-UNV % 94% F <10% A QQ 25 4 AB4-32-PS-UNV % 89% F <10% A QQ HIGH 17 1 AB1-32-IP-UNV-HE % 92% F <20% H A EFFICIENCY 17 1 AB1-32-IP-UNV-HE % 92% F <20% H A 17 1 AB2-32-IP-UNV-HE % 105% F <20% H U 17 1 AB2-32-IP-UNV-HE % 105% F <20% H U STANDARD 17 1 AB1-32-IP % 91% F <25% A A 17 1 AB1-32-IP % 91% F <30% A A 17 1 AB1-32-IP-UNV % 92% F <10% A A 17 1 AB1-32-IP-UNV % 92% F <10% A A 17 1 AB2-32-IP % 116% F 33% A U 17 1 AB2-32-IP % 116% F 32% A U RESIDENTIAL 17 1 AB2-32-IP-120-R >50% 108% F <200% H U PROGRAM 17 1 AB2-32-PS-UNV % 96% F <15% A H START 17 1 AB2-32-PS-UNV % 96% F <15% A H LOW 17 1 AB2-32-IP-UNV-LX % 107% F <20% H U 17 1 AB2-32-IP-UNV-LX % 107% F <20% H U 17 1 AB2-32-IP-120-LX % 107% F <20% A U 17 1 AB2-32-IP-277-LX % 107% F <20% A U HIGH 17 1 AB2-32-IP-UNV-HX % 130% F <10% A U HIGH 17 2 AB2-32-IP-UNV-HE % 91% F <20% H B EFFICIENCY 17 2 AB2-32-IP-UNV-HE % 91% F <20% H B 17 2 AB3-32-IP-UNV-HE % 105% F <20% A V 17 2 AB3-32-IP-UNV-HE % 105% F <20% A V STANDARD 17 2 AB2-32-IP-UNV % 91% F <20% A B 17 2 AB2-32-IP-UNV % 91% F <20% A B 17 2 AB2-32-IP % 94% F <30% A B 17 2 AB2-32-IP % 96% F <30% A B 17 2 AB3-32-IP-UNV % 106% F <10% A V 17 2 AB3-32-IP-UNV % 106% F <30% A V 17 2 AB3-32-IP % 112% F <30% A V 17 2 AB3-32-IP % 116% F <30% A V RESIDENTIAL 17 2 AB2-32-IP-120-R % 90% F <150% H B PROGRAM 17 2 AB2-32-PS-UNV % 89% F <15% A F START 17 2 AB2-32-PS-UNV % 89% F <15% A F LOW 17 2 AB2-32-IP-UNV-LX % 85% F <20% H B 17 2 AB2-32-IP-UNV-LX % 85% F <20% H B 17 2 AB3-32-IP-UNV-LX % 100% F <20% A V 17 2 AB3-32-IP-UNV-LX % 100% F <20% A V 16

19 ELECTRONIC BALLASTS: T8 LAMPS LAMP APPLICATIONS: F17T8, F40T8, F40T12, F34T12, F96T8 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F17T8 HIGH 17 2 AB2-32-IP-UNV-HX % 118% F <10% A B 17 2 AB2-32-IP-UNV-HX % 118% F <10% A B 17 2 AB3-32-IP-UNV-HX % 142% F <10% A V 17 2 AB3-32-IP-UNV-HX % 142% F <10% A V HIGH 17 3 AB3-32-IP-UNV-HE % 92% F <20% A C EFFICIENCY 17 3 AB3-32-IP-UNV-HE % 92% F <20% A C 17 3 AB4-32-IP-UNV-HE % 102% F <20% A W 17 3 AB4-32-IP-UNV-HE % 102% F <20% A W STANDARD 17 3 AB3-32-IP-UNV % 91% F <10% A C 17 3 AB3-32-IP-UNV % 91% F <20% A C 17 3 AB3-32-IP % 96% F <20% A C 17 3 AB3-32-IP % 98% F <32% A C 17 3 AB4-32-IP-UNV % 99% F <20% A W 17 3 AB4-32-IP-UNV % 99% F <20% A W 17 3 AB4-32-IP % 94% F <10% A W 17 3 AB4-32-IP % 94% F <20% A W RESIDENTIAL 17 3 AB4-32-IP-120-R >50% 91% F <200% A W PROGRAM 17 3 AB4-32-PS-UNV % 95% F <20% A QQ START 17 3 AB4-32-PS-UNV % 95% F <20% A QQ LOW 17 3 AB3-32-IP-UNV-LX % 85% F <20% A C 17 3 AB3-32-IP-UNV-LX % 85% F <20% A C 17 3 AB4-32-IP-UNV-LX % 94% F <20% A W 17 3 AB4-32-IP-UNV-LX % 94% F <20% A W HIGH 17 3 AB3-32-IP-UNV-HX % 1.19% F <10% A C 17 3 AB3-32-IP-UNV-HX % 1.19% F <10% A C HIGH 17 4 AB4-32-IP-UNV-HE % 92% F <20% A D EFFICIENCY 17 4 AB4-32-IP-UNV-HE % 92% F <20% A D STANDARD 17 4 AB4-32-IP-UNV % 91% F <20% A D 17 4 AB4-32-IP-UNV % 91% F <20% A D 17 4 AB4-32-IP % 88% F <10% A D 17 4 AB4-32-IP % 89% F <20% A D RESIDENTIAL 17 4 AB4-32-IP-120-R % 83% F <200% A D PROGRAM 17 4 AB4-32-PS-UNV % 90% F <20% A QQ START 17 4 AB4-32-PS-UNV % 90% F <20% A QQ LOW 17 4 AB4-32-IP-UNV-LX % 85% F <20% A D 17 4 AB4-32-IP-UNV-LX % 85% F <20% A D F40T8 HIGH 40 1 AB2-32-IP-UNV-HE % 98% F <10% H U EFFICIENCY 40 1 AB2-32-IP-UNV-HE % 98% F <10% H U STANDARD 40 1 AB2-32-IP-UNV % 97% F <20% A U 40 1 AB2-32-IP-UNV % 97% F <20% A U 40 1 AB2-32-IP % 106% F <25% A U 40 1 AB2-32-IP % 106% F <25% A U PROGRAM 40 1 AB2-32-PS-UNV % 89% F <10% A H START 40 1 AB2-32-PS-UNV % 89% F <10% A H HIGH 40 2 AB3-32-IP-120-HE % 102% F <10% A V EFFICIENCY 40 2 AB3-32-IP-277-HE % 102% F <10% A V STANDARD 40 2 AB3-32-IP-UNV % 96% F <20% A V 40 2 AB3-32-IP-UNV % 96% F <20% A V 40 2 AB3-32-IP % 100% F <20% A V 40 2 AB3-32-IP % 102% F <20% A V HIGH 40 3 AB4-32-IP-120-HE % 94% F <10% A W EFFICIENCY 40 3 AB4-32-IP-277-HE % 94% F <10% A W STANDARD 40 3 AB4-32-IP-UNV % 96% F <10% A W 40 3 AB4-32-IP-UNV % 96% F <10% A W 40 3 AB4-32-IP % 96% F <20% A W 40 3 AB4-32-IP % 96% F <20% A W F40T12 RESIDENTIAL 40 1 AB2-32-IP-120-R % 69% F <150% H U 40 2 AB2-32-IP-120-R % 57% F <150% H B 40 3 AB4-32-IP-120-R % 60% F <150% A W 40 4 AB4-32-IP-120-R % 55% F <150% A D F34T12 RESIDENTIAL 34 1 AB2-32-IP-120-R % 68% F <200% H U 34 2 AB2-32-IP-120-R % 57% F <150% H B 34 3 AB4-32-IP-120-R % 58% F <200% A W 34 4 AB4-32-IP-120-R % 54% F <200% A D F96T8 STANDARD 59 1 AB2-59-IP-UNV % 117% F <10% A U 59 1 AB2-59-IP-UNV % 117% F <10% A U STANDARD 59 2 AB2-59-IP-UNV % 101% F <10% A B 59 2 AB2-59-IP-UNV % 102% F <10% A B Ballast Specification Guide 17

20 Ballast Specification Guide 18 T5 PROGRAMMED Start - Universal Voltage T5 - T5/HO - TT5 Ballast Models Include: Programmed Start Rapid Start T5 Linear Ballast Highlights: T5/HO TT5 All ballasts (1 and 2 lamp models) are designed with series circuitry. All ballasts shall have ELP (End-Of-Life Protection) shut down circuitry and auto restart functions to eliminate the need to cycle power after re-lamping. Ballasts shall be UNV and operate from 60Hz input source (108V or 305V), and sustain voltage variations of ±10%. Ballasts are high frequency, electronic-type models that operate lamps at a frequency higher than 20kHz. UNV models may operate lamps at a frequency between 40-52kHz or greater to avoid interference with infrared devices. Lamp current crest factor (peak lamp current/average lamp current) shall be 1.7 or less in accordance with lamp manufacturer recommendation ANSI C Ballasts shall operate in ambient temperatures up to 40 C and ballast case temperatures up to 90 C without damage. Ballasts shall comply with FCC Part 18, Class A (non-consumer) regulations for EMI levels (conducted and radiated). Ballasts shall provide transient immunity as recommended by ANSI C Ballasts shall be UL Listed (UL 935), Class P, Type 1 Outdoor, and CSA certified as required. Ballasts shall operate lamps at less than 3% flicker index (virtually non visible flicker). Ballasts shall have a ballast factor greater than.98. Total Harmonic Distortion (THD) shall not exceed 10% for the primary lamp applications. Ballast shall have a Power Factor (ratio between real power and apparent power) greater than.98 for primary lamp applications. Ballasts shall not contain any (polychlorinated biphenyls). Ballasts shall have a Class A sound rating. Ballasts shall be manufactured in an ISO 9001-certified facility. Ballasts shall be provided with lead wires, color-coded in accordance with ANSI C82.11 standards. Ballasts shall be potted and are contained within a metal enclosure for optimum thermal performance. Ballasts shall be either remote- or tandem-wired up to a maximum of 18 feet overall lead length, measured from ballast to lamps. (Consult American Ballast engineering department for specific applications). American Ballast shall provide written warranty against defects in material or workmanship, including replacement for a period of five years from date of manufacture.

21 T5 PROGRAMMED Start - Universal Voltage T5 - T5/HO - TT5 One ballast operates multiple lamp types Features and Benefits: Small profile case Ideal for narrow profile fixtures Optimizes luminaires for T5 and T5HO lamp optics Universal input voltage ( V, 50/60Hz) Reduces inventory costs and requirements Correct voltage is always available Program rapid start for long lamp life Ideal for long and short cycle applications Low temperature starting: -20 F Ideal for refrigeration installations End-of-lamp-life shutdown circuitry Safely powers down lamp at end-of-life New lamp ignites upon insertion Auto restart after lamp replacement No need to cycle power when replacing lamps Total Harmonic Distortion < 10% Lighter weight - Easier to install - Less shipping cost - Ideal for suspended fixtures Supports 14-, 21-, 28- and 35-watt T5 lamps Supports 1 or 2: 24-, 39- and 54-watt T5HO lamps Supports 1 or 2: 24-, 40-, 50- and 55-watt Long Twin tube lamps UL and CuL Listed Applicable models meet Energy Star requirements Ballast Specification Guide Applications: Atriums Gymnasiums Lobbies Hotels Offices Schools Industrial/Manufacturing Restaurants Boardrooms Auditoriums Training Areas Specialty Stores Conference Rooms Department Stores Houses of Worship Healthcare Facilities 19

22 Ballast Specification Guide 20 ELECTRONIC BALLASTS: TT5 (TWIN), T5 linear & t5/40 lamps LAMP APPLICATIONS: FT55T5, FT50T5, FT40T5, FT39T5, FT36T5, FT27/24T5, FT18T5, F35T5, F28T5, F21T5, F14T5, f54t5ho, f39t5ho, f24t5ho TT5 (TWIN) PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. FT55T5 STANDARD 55 1 AB2-54-PS-UNV % 94% F <10% G M 55 1 AB2-54-PS-UNV % 94% F <10% G M 55 2 AB2-54-PS-UNV % 92% F <10% G N 55 2 AB2-54-PS-UNV % 92% F <10% G N FT50T5 STANDARD 50 1 AB2-54-PS-UNV % 110% F <10% G M 50 1 AB2-54-PS-UNV % 110% F <10% G M 50 2 AB2-54-PS-UNV % 106% F <10% G N 50 2 AB2-54-PS-UNV % 106% F <10% G N FT40T5 STANDARD 40 1 AB2-40-PS-UNV-BX % 105% F <10% H M 40 1 AB2-40-PS-UNV-BX % 106% F <10% H M 40 1 AB2-32-IP-UNV % 100% F <10% A I 40 1 AB2-32-IP-UNV % 100% F <10% A I 40 1 AB2-26-PS-UNV-CF % 98% F <10% AA M 40 1 AB2-26-PS-UNV-CF % 98% F <10% AA M 40 1 AB2-32-IP % 95% F <20% A I 40 1 AB2-32-IP % 95% F <20% A I 40 2 AB2-40-PS-UNV-BX % 100% F <10% H N 40 2 AB2-40-PS-UNV-BX % 100% F <10% H N 40 2 AB3-32-IP-UNV % 88% F <10% A J 40 2 AB3-32-IP-UNV % 88% F <10% A J 40 2 AB2-42-PS-UNV-CF % 89% F <10% BB N 40 2 AB2-42-PS-UNV-CF % 89% F <10% BB N 40 2 AB3-32-IP % 90% F <10% A J 40 2 AB3-32-IP % 90% F <10% A J 40 3 AB4-32-IP-UNV % 81% F <10% A K 40 3 AB4-32-IP-UNV % 81% F <10% A K 40 3 AB4-32-IP % 84% F <10% A K 40 3 AB4-32-IP % 84% F <10% A K FT39T AB2-40-PS-UNV-BX % 100% F <10% H M 39 1 AB2-40-PS-UNV-BX % 100% F <10% H M 39 2 AB2-40-PS-UNV-BX >99% 100% F <10% H N 39 2 AB2-40-PS-UNV-BX >99% 100% F <10% H N FT36T5 STANDARD 36 1 AB2-32-IP-UNV % 76% F <10% A I 36 1 AB2-32-IP-UNV % 76% F <10% A I 36 1 AB2-32-IP % 79% F <10% A I 36 1 AB2-32-IP % 79% F <10% A I 36 2 AB3-32-IP-UNV % 72% F <10% A J 36 2 AB3-32-IP-UNV % 72% F <10% A J 36 2 AB3-32-IP % 78% F <10% A J 36 2 AB3-32-IP % 78% F <10% A J 36 3 AB4-32-IP-UNV % 72% F <10% A K 36 3 AB4-32-IP-UNV % 72% F <10% A K 36 3 AB4-32-IP % 72% F <10% A K 36 3 AB4-32-IP % 72% F <10% A K FT27/24T5 STANDARD 27/24 1 AB2-32-IP-UNV % 81% F <10% A I 27/24 1 AB2-32-IP-UNV % 81% F <10% A I 27/24 1 AB2-32-IP % 81% F <10% A I 27/24 1 AB2-32-IP % 81% F <10% A I 27/24 2 AB2-32-IP-UNV % 73% F <10% A PP 27/24 2 AB2-32-IP-UNV % 73% F <10% A PP 27/24 2 AB2-32-IP % 73% F <10% A PP 27/24 2 AB2-32-IP % 73% F <10% A PP 27/24 2 AB3-32-IP-UNV % 70% F <10% A J 27/24 2 AB3-32-IP-UNV % 70% F <10% A J 27/24 2 AB3-32-IP % 78% F <10% A J 27/24 2 AB3-32-IP % 78% F <10% A J 27/24 3 AB3-32-IP-UNV % 65% F <10% A NN 27/24 3 AB3-32-IP-UNV % 65% F <10% A NN 27/24 3 AB3-32-IP % 70% F <10% A NN 27/24 3 AB3-32-IP % 70% F <10% A NN 27/24 3 AB4-32-IP-UNV % 72% F <10% A K 27/24 3 AB4-32-IP-UNV % 72% F <10% A K 27/24 3 AB4-32-IP % 72% F <10% A K 27/24 3 AB4-32-IP % 72% F <10% A K 27/24 4 AB4-32-IP-UNV % 70% F <10% A OO 27/24 4 AB4-32-IP-UNV % 70% F <10% A OO 27/24 4 AB4-32-IP % 70% F <10% A OO 27/24 4 AB4-32-IP % 70% F <10% A OO

23 ELECTRONIC BALLASTS:T5 LINEAR LAMPS LAMP APPLICATIONS: F35T5, F28T5, F21T5, F14T5 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. FT18T5 STANDARD 18 1 AB2-32-IP-UNV % 72% F <10% A I 18 1 AB2-32-IP-UNV % 72% F <10% A I 18 1 AB2-32-IP % 72% F <10% A I 18 1 AB2-32-IP % 72% F <10% A I 18 2 AB2-32-IP-UNV % 72% F <10% A PP 18 2 AB2-32-IP-UNV % 72% F <10% A PP 18 2 AB2-32-IP % 72% F <10% A PP 18 2 AB2-32-IP % 72% F <10% A PP 18 2 AB3-32-IP-UNV % 67% F <10% A J 18 2 AB3-32-IP-UNV % 67% F <10% A J 18 2 AB3-32-IP % 78% F <10% A J 18 2 AB3-32-IP % 78% F <10% A J 18 3 AB3-32-IP-UNV % 65% F <10% A NN 18 3 AB3-32-IP-UNV % 65% F <10% A NN 18 3 AB3-32-IP % 73% F <10% A NN 18 3 AB3-32-IP % 73% F <10% A NN 18 3 AB4-32-IP-UNV % 75% F <10% A K 18 3 AB4-32-IP-UNV % 75% F <10% A K 18 3 AB4-32-IP % 75% F <10% A K 18 3 AB4-32-IP % 75% F <10% A K 18 4 AB4-32-IP-UNV % 71% F <10% A OO 18 4 AB4-32-IP-UNV % 71% F <10% A OO 18 4 AB4-32-IP % 71% F <10% A OO 18 4 AB4-32-IP % 71% F <10% A OO T5 linear Ballast Specification Guide PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F35T5 STANDARD 35 1 AB2-28-PS-UNV % 102% F <10% G H 35 1 AB2-28-PS-UNV % 102% F <10% G H F28T5 STANDARD 28 1 AB2-28-PS-UNV % 100% F <10% G H 28 1 AB2-28-PS-UNV % 100% F <10% G H 28 2 AB2-28-PS-UNV % 100% F <10% G F 28 2 AB2-28-PS-UNV % 100% F <10% G F F21T5 STANDARD 21 1 AB2-28-PS-UNV % 104% F <10% G H 21 1 AB2-28-PS-UNV % 104% F <10% G H 21 2 AB2-28-PS-UNV % 100% F <10% G F 21 2 AB2-28-PS-UNV % 100% F <10% G F F14T5 STANDARD 14 1 AB2-28-PS-UNV % 106% F <10% G H 14 1 AB2-28-PS-UNV % 106% F <10% G H 14 2 AB2-28-PS-UNV % 100% F <10% G F 14 2 AB2-28-PS-UNV % 100% F <10% G F T5/HO PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F54T5HO STANDARD 54 1 AB2-54-PS-UNV % 105% F <10% G H 54 1 AB2-54-PS-UNV % 105% F <10% G H 54 2 AB2-54-PS-UNV % 100% F <10% G F 54 2 AB2-54-PS-UNV % 100% F <10% G F 54 3 AB4-54-PS-UNV % 103% F <10% G-1 SS 54 3 AB4-54-PS-UNV % 103% F <10% G-1 SS 54 4 AB4-54-PS-UNV % 100% F <10% G-1 SS 54 4 AB4-54-PS-UNV % 100% F <10% G-1 SS F39T5HO STANDARD 39 2 AB2-39-PS-UNV % 100% F <10% G F 39 2 AB2-39-PS-UNV % 100% F <10% G F 39 1 AB2-39-PS-UNV % 118% F <10% G H 39 1 AB2-39-PS-UNV % 118% F <10% G H F24T5HO STANDARD 24 2 AB2-39-PS-UNV % 120% F <10% G F 24 2 AB2-39-PS-UNV % 120% F <10% G F 24 1 AB2-39-PS-UNV % 130% F <10% G H 24 1 AB2-39-PS-UNV % 130% F <10% G H 21

24 Ballast Specification Guide 22 T12 4 and 8 - Dedicated and Universal Voltage Ballast Models Include: Instant Start/Rapid Start Models Ballast Highlights: Instant start ballasts (1, 2, 3, or 4 lamp models) are designed with parallel circuitry enabling the remaining lamps to maintain full light output if one or more lamps fail to operate. (Rapid start models are designed with series circuitry). Ballasts shall operate from 60Hz input source (120V), and sustain voltage variations of ±10%. Ballasts are high frequency, electronic-type models that operate lamps at a frequency higher than 20kHz. Lamp current crest factor (peak lamp current/average lamp current) shall be 1.7 or less in accordance with lamp manufacturer recommendation ANSI C Ballasts shall operate in ambient temperatures up to 40 C and ballast case temperatures up to 90 C without damage. Ballasts shall comply with FCC Part 18, Class B (consumer) regulations in regards to EMI levels (conducted and radiated). Ballasts shall provide transient immunity as recommended under ANSI C Ballasts shall be UL Listed (UL 935), Class P, Type 1 Outdoor; and CSA-certified as required. Ballasts shall operate lamps at less than 3% flicker index (virtually nonvisible flicker). Normal light output ballasts shall exhibit a ballast factor greater than.87. Ballasts shall have a Power Factor (ratio between real power and apparent power) greater than.98 for primary lamp applications. Ballasts shall not contain PCBs (polychlorinated biphenyls). Ballasts shall have a Class A sound rating. Ballasts shall be manufactured in an ISO 9001-certified facility. Ballasts shall be provided with lead wires, color-coded in accordance with ANSI C82.11 standards. Ballasts shall be potted and are contained within a metal enclosure for optimum thermal performance. Ballasts shall be either remote- or tandem-wired up to a maximum of 18 feet overall lead length, measured from ballast to lamps. (Consult American Ballast engineering department for specific applications). American Ballast shall provide written warranty against defects in material or workmanship, including replacement for a period of five years from date of manufacture.

25 T12 Electronic / 277 Voltage 4-foot T12 / 8-foot T12 - Universal Voltage One ballast operates multiple lamp types Features and Benefits: Energy efficient Greater than 20% increase in efficiency over magnetic ballasts Lower lighting operation costs Full light output Provides same light levels as magnetic ballast being replaced Quiet operation Significantly quieter than magnetic ballasts High frequency operation No lamp flickering Lighter weight - Easier to install - Less shipping cost - Ideal for suspended fixtures Less interference with ballast channel cover during replacement Slimline ballasts feature parallel lamp operation keeps other lamps functions when one lamp fails Same warranty as energy saving magnetic types Minimum starting temperatures: - HO Models: -20 F - Slimline Models: 50ºF - 4-foot Models: 32ºF Sound rating: Class A Operates within ±10% of the ballast specified line voltage at 60Hz Comply with the limits of FCC Part 18C, Class A UL and CuL Listed Applicable models meet Energy Star requirements Ballast Specification Guide Applications: General Shopping Areas Gymnasiums Manufacturing Outdoor Parking Garages Shipping/Receiving Warehouses 23

26 Ballast Specification Guide ELECTRONIC BALLASTS: T12 Lamps - 8 foot & 4 foot LAMP APPLICATIONS: T12 8 Foot: F96T12/HO, F96T12/HO/ES, F72T12/HO, F60T12/HO, F48T12/HO PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. F96T12HO HIGH OUTPUT AB2-96HO-RS % 103% F <10% D-1 H AB2-96HO-RS % 103% F <10% D-1 H AB2-96HO-RS % 90% F <10% D-1 F AB2-96HO-RS % 90% F <10% D-1 F F96T12HO/ES HIGH OUTPUT 95 1 AB2-96HO-RS % 103% F <15% D-1 H 95 1 AB2-96HO-RS % 103% F <15% D-1 H 95 2 AB2-96HO-RS % 89% F <10% D-1 F 95 2 AB2-96HO-RS % 89% F <10% D-1 F F72T12HO HIGH OUTPUT 85 1 AB2-96HO-RS % 105% F <15% D-1 H 85 1 AB2-96HO-RS % 105% F <15% D-1 H 85 2 AB2-96HO-RS % 90% F <10% D-1 F 85 2 AB2-96HO-RS % 90% F <10% D-1 F F60T12HO HIGH OUTPUT 75 1 AB2-96HO-RS % 108% F <15% D-1 H 75 1 AB2-96HO-RS % 108% F <15% D-1 H 75 2 AB2-96HO-RS % 96% F <10% D-1 F 75 2 AB2-96HO-RS % 96% F <10% D-1 F F48T12HO HIGH OUTPUT 60 1 AB2-96HO-RS % 112% F <15% D-1 H 60 1 AB2-96HO-RS % 112% F <15% D-1 H 60 2 AB2-96HO-RS % 99% F <10% D-1 F 60 2 AB2-96HO-RS % 99% F <10% D-1 F F96T12 STANDARD 75 1 AB2-96-IP % 105% F <10% C U 75 1 AB2-96-IP % 105% F <10% C U 75 2 AB2-96-IP % 95% F <10% C B 75 2 AB2-96-IP % 95% F <10% C B F96T12/ES STANDARD 60 1 AB2-96-IP % 107% F <10% C U 60 1 AB2-96-IP % 107% F <10% C U 60 2 AB2-96-IP % 94% F <10% C B 60 2 AB2-96-IP % 94% F <10% C B F84T12 STANDARD 70 1 AB2-96-IP % 105% F <10% C U 70 1 AB2-96-IP % 105% F <10% C U 70 2 AB2-96-IP % 96% F <10% C B 70 2 AB2-96-IP % 96% F <10% C B F72T12 STANDARD 57 1 AB2-96-IP % 117% F <10% C U 57 1 AB2-96-IP % 117% F <10% C U 57 2 AB2-96-IP % 103% F <10% C B 57 2 AB2-96-IP % 103% F <10% C B F64T12 STANDARD 52 1 AB2-96-IP % 115% F <10% C U 52 1 AB2-96-IP % 115% F <10% C U 52 2 AB2-96-IP % 101% F <10% C B 52 2 AB2-96-IP % 101% F <10% C B F60T12 STANDARD 50 1 AB2-96-IP % 115% F <10% C U 50 1 AB2-96-IP % 115% F <10% C U 50 2 AB2-96-IP % 100% F <10% C B 50 2 AB2-96-IP % 100% F <10% C B F48T12 STANDARD 39 1 AB2-96-IP % 113% F <10% C U 39 1 AB2-96-IP % 113% F <10% C U 39 2 AB2-96-IP % 97% F <10% C B 39 2 AB2-96-IP % 97% F <10% C B LAMP APPLICATIONS: T12 4 Foot: F40T12, F40T10, F34T12 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. 24 F40T12 STANDARD 40 1 AB2-40-RS % 103% F <30% A H 40 1 AB2-40-RS % 103% F <30% A H 40 2 AB2-40-RS % 88% F <20% A F 40 2 AB2-40-RS % 88% F <20% A F F40T10 STANDARD 40 1 AB2-40-RS % 104% F <30% A H 40 1 AB2-40-RS % 104% F <30% A H 40 2 AB2-40-RS % 89% F <20% A F 40 2 AB2-40-RS % 89% F <20% A F F34T12 STANDARD 34 1 AB2-40-RS % 104% F <30% A H 34 1 AB2-40-RS % 104% F <30% A H 34 2 AB2-40-RS % 91% F <20% A F 34 2 AB2-40-RS % 91% F <20% A F

27 Energy Policy Act Update: Fluorescent Ballast Requirements and Efficacy factor Increases A new ruling by the Department of Energy was finalized already to reduce energy emissions and provide significant energy savings. The commercial and industrial lighting sectors will be subject to new energyefficient lighting regulations beginning April 1, Under these regulations OEMs (Original Equipment Manufacturers) can no longer use ballasts in new lighting fixtures, from ballast manufacturers, unless the ballasts meet the new minimum BEF (Ballast Efficacy Factor) requirements. The new regulations target ballasts that operate T12 fluorescent lamps. There is a differentiation in the effective date for these ballasts in regards to installation into new fixtures vs. the replacement of ballasts in the field and/or the sale of replacement ballasts. Based on existing technologies today, only the electronic ballasts comply with these new DOE guidelines. A summary of the new regulation, effective dates, and exemptions are listed below: BALLAST REGULATIONS: Effective Dates: April 1, Ballast manufacturers can no longer produce ballast that do not meet the minimum efficiency requirements that are intended for sale to OEM s. Production of these products for replacement use is still allowed but the products must be marked for replacement use only and incorporate short lead wires. July 1, Ballast manufacturers can no longer sell ballasts that do not meet the minimum efficiency requirements to OEM s for installation into new luminaires. April 1, Lighting fixture manufacturers can no longer incorporate ballasts that do not meet the new BEF requirements in new fixtures. July 1, Ballasts manufacturers can no longer sell ballasts that do not meet the minimum efficiency requirements for replacement. BEF Requirements: Application Ballast Voltage BEF Requirement One F40T12 Lamp 120 or Two F40T12 Lamps 120 or Two F96T12 Lamps 120 or Two F96T12HO Lamps 120 or Minimum requirements have to be set for T8 lamps, since there are few applications where electronic ballasts would not be used and the low frequency magnetic ballasts would be necessary. T12 Magnetic Ballasts: T12 magnetic ballasts, for REPLACEMENT purposes, in existing installations can be manufactured until June 30, 2010, but MUST meet the following requirements: Ballast label must state For Replacement Use Only Ballast leads shall be shorter than the length of lamps (intended) to operate Ballasts shipped in packages not exceeding 10 units Meet existing T12 magnetic BEF criteria Exceptions: T12 dimming ballasts that dim to 50% or less Two lamp F96T12HO ballasts designed for -20F operation and used in an outdoor sign Magnetic ballasts with PF less than 0.90 designed and labeled for residential applications Ballast Specification Guide 25

28 Ballast Specification Guide 26 Compact Fluorescent T5 Circline & 2-D Universal voltage Ballast Models Include: T5 Circline 2-D Universal Voltage Ballast Highlights: All ballasts (1 and 2 lamp models) are designed with series circuitry. All ballasts shall have ELP (End-Of-Life Protection) shut down circuitry and auto-restart functions to eliminate the need to cycle power after re-lamping. Ballast shall be UNV model and operate at either 50 or 60Hz input sources (108 to 305V), and sustain voltage variations of ±10%. Ballasts are high frequency, electronic-type models that operate lamps at a frequency higher than 20kHz. UNV models may operate lamps at a frequency of 42Khz or greater to avoid interference with infrared devices. Lamp current crest factor (peak lamp current/average lamp current) shall be 1.7 or less in accordance with lamp manufacturer recommendation ANSI C Ballasts shall operate in ambient temperatures up to 40 C and ballast case temperatures up to 90 C without damage. Ballasts shall comply with FCC Part 18, Class A (non-consumer) regulations for EMI levels (conducted and radiated). Ballasts shall provide transient immunity as recommended under ANSI C Ballasts shall be UL Listed (UL 935), Class P, Type 1 Outdoor; and CSAcertified as required. Ballasts shall operate lamps at less than 3% flicker index (virtually non-visible flicker). Ballasts have a ballast factor greater than.98. Total Harmonic Distortion (THD) shall not exceed 10% for primary lamp applications. Ballasts shall have a Power Factor (ratio between real power and apparent power) greater than.98 for primary lamp applications. Ballasts shall not contain PCBs (polychlorinated biphenyls). Ballasts shall have a Class A sound rating. Ballasts shall be manufactured in an ISO 9001-certified facility. Ballasts shall be provided with connectors, color-coded in accordance with ANSI C82.11 standards. Ballasts shall be potted and are contained within a metal enclosure for optimum thermal performance. Ballasts shall be either remote- or tandem-wired up to a maximum of 18 feet overall lead length, measured from ballast to lamps. (Consult American Ballast engineering department for specific applications). American Ballast shall provide written warranty against defects in material or workmanship, including replacement for a period of five years from date of manufacture.

29 Compact fluorescent Programmed Start & Universal Voltage One ballast operates multiple lamp types Applications: Auditoriums Boardrooms Conference Rooms Display Areas Educational Facilities Healthcare Facilities Hotels Features and Benefits: Universal input voltage of 108 to 305 volts Installer-friendly ensures you have the right ballast every time Reduces inventory costs and requirements Metal can construction Meets all plenum requirements No exposed plastic (Base Exit/Base Exit Stud versions) Maximum heat transfer to fixture 1- or 2-lamp operation of multiple lamp applications Color-coded connectors increase wiring accuracy Duel entry terminal blocks significantly reduce assembly and ballast installation time End-of-lamp-life shutdown circuitry Safely powers down lamp at end-of-life New lamp ignites upon insertion Auto restart after lamp replacement No need to cycle power when replacing lamps Total Harmonic Distortion < 10%; Power Factor >.98 Sound rating: Class A Meets Class P, Type 1 Outdoor standard Operates within ±10% of the ballast specified line voltage of 50/60Hz Complies with the limits of FCC Part 18C for non-consumer equipment Programmed Rapid Starting (PRS) Meets all requirements of rapid start specifications Increases lamp life for frequently switched applications (occupancy sensors) Temperature test point of 90ºC Allows for easy ballast and fixture testing, assuring proper temperature application Maximum case temperature of 90 C UL and CuL Listed Houses of Worship Applicable models meet Energy Star requirements Private and Executive Offices Restaurants Specialty Stores Stairways Ballast Specification Guide 27

30 Ballast Specification Guide ELECTRONIC BALLASTS: COMPACT LAMPS LAMP APPLICATIONS: CFQ13, CFTR13, CFQ26, CFTR26, CFTR32, CFTR42, CFM57, CFM70 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. CFQ13 STANDARD 13 1 AB2-13-PS-UNV-CF % 100% ºF <10% AA Q 13 1 AB2-13-PS-UNV-CF % 100% ºF <10% AA Q 13 2 AB2-13-PS-UNV-CF % 98% ºF <10% AA R 13 2 AB2-13-PS-UNV-CF % 98% ºF <10% AA R CFQ18 STANDARD 18 1 AB2-18-PS-UNV-CF % 100% ºF <10% AA Q CFTR AB2-18-PS-UNV-CF % 100% ºF <10% AA Q 18 2 AB2-18-PS-UNV-CF % 98% ºF <10% AA R 18 2 AB2-18-PS-UNV-CF % 98% ºF <10% AA R CFQ26 STANDARD 26 1 AB2-26-PS-UNV-CF % 100% ºF <10% AA Q CFTR AB2-26-PS-UNV-CF % 100% ºF <10% AA Q 26 2 AB2-26-PS-UNV-CF % 100% ºF <10% AA R 26 2 AB2-26-PS-UNV-CF % 100% ºF <10% AA R 26 2 AB2-42-PS-UNV-CF % 100% ºF <10% BB R 26 2 AB2-42-PS-UNV-CF % 100% ºF <10% BB R CFTR32 STANDARD 32 1 AB2-26-PS-UNV-CF % 98% ºF <10% AA Q 32 1 AB2-26-PS-UNV-CF % 98% ºF <10% AA Q 32 2 AB2-42-PS-UNV-CF % 98% ºF <10% BB R 32 2 AB2-42-PS-UNV-CF % 98% ºF <10% BB R CFTR42 STANDARD 42 1 AB2-26-PS-UNV-CF % 98% ºF <10% AA Q 42 1 AB2-26-PS-UNV-CF % 98% ºF <10% AA Q 42 1 AB2-42-PS-UNV-CF % 100% ºF <10% BB Q 42 1 AB2-42-PS-UNV-CF % 100% ºF <10% BB Q 42 2 AB2-42-PS-UNV-CF % 98% ºF <10% BB R 42 2 AB2-42-PS-UNV-CF % 98% ºF <10% BB R CFTR57 STANDARD 57 1 AB2-42-PS-UNV-CF % 100% ºF <10% BB Q 57 1 AB2-42-PS-UNV-CF % 100% ºF <10% BB Q CFM70 STANDARD 70 1 AB2-42-PS-UNV-CF % 100% ºF <10% BB Q 70 1 AB2-42-PS-UNV-CF % 100% 137 0ºF <10% BB Q ELECTRONIC BALLASTS: T5 CIRCLINE AND 2-D LAMPS LAMP APPLICATIONS: FC9T5, FC12T5, CFS10, CFS16, CFS21, CFS28, CFS38 PRIMARY LAMP Power Lamp No. of Model Line Input Input Power Ballast Min. Start THD Can Wire LOAD Level Watts Lamps Number Volt Watts Current Factor Factor % B.E.F. Temp. % Size Diag. 28 FC9T5 STANDARD 22W 1 AB2-26-PS-UNV-CF % 100% ºF <10% AA O 22W 1 AB2-39-PS-UNV % 120% F <10% G O 22W 1 AB2-39-PS-UNV % 120% F <10% G O 22W 2 AB2-26-PS-UNV-CF % 100% F <10% AA P 22W 2 AB2-39-PS-UNV % 120% F <10% G P 22W 2 AB2-39-PS-UNV % 120% F <10% G P FC12T5 STANDARD 40W 1 AB2-26-PS-UNV-CF % 95% F <20% AA O 40W 2 AB2-26-PS-UNV-CF % 95% F <20% AA P FC9T5 & STANDARD 22W & 40W BOTH AB2-42-PS-UNV-CF % 85% F <10% BB P FC12T5 22W & 40W BOTH AB2-42-PS-UNV-CF % 85% F <10% BB P CFS10 STANDARD 10W 1 AB2-13-PS-UNV-CF % 102% F <10% AA Q 10W 1 AB2-13-PS-UNV-CF % 102% F <10% AA Q 10W 2 AB2-13-PS-UNV-CF % 102% F <10% AA R 10W 2 AB2-13-PS-UNV-CF % 102% ºF <10% AA R CFS16 STANDARD 16W 1 AB2-13-PS-UNV-CF % 95% F <10% AA Q 16W 1 AB2-13-PS-UNV-CF % 95% F <10% AA Q 16W 2 AB2-13-PS-UNV-CF % 95% F <10% AA R 16W 2 AB2-13-PS-UNV-CF % 95% F <10% AA R CFS21 STANDARD 21W 1 AB2-18-PS-UNV-CF % 98% F <10% AA Q 21W 1 AB2-18-PS-UNV-CF % 98% F <10% AA Q 21W 2 AB2-18-PS-UNV-CF % 95% F <10% AA R 21W 2 AB2-18-PS-UNV-CF % 95% F <10% AA R CFS28 STANDARD 28W 1 AB2-26-PS-UNV-CF % 100% F <10% AA Q 28W 1 AB2-26-PS-UNV-CF % 100% F <10% AA Q CFS38 STANDARD 38W 1 AB2-26-PS-UNV-CF % 85% F <10% AA Q 38W 1 AB2-26-PS-UNV-CF % 85% F <10% AA Q

31 ordering information The alpha/numeric catalog number provides a complete description of any American Ballast. AB 2 32 I P 120 XXX Speciality Design/Model Specific: LX : Low Power, 78 Ballast Factor HX : High Power, 1.18 Ballast Factor BX : Biax HE : High Efficiency R : Residential Input Line Voltage 120 = 120 Volts 240 = 240 Volts 277 = 277 Volts 220 = 220 Volts 347 = 347 Volts UNV = Universal Input Ballast Specification Guide Ballast Wiring Method P : Parallel Wired Ballast S : Series Wired Ballast Lamp Starting Method I = Instant Start R = Rapid Start P = Programmed Start Lamp Watts Maximum number of lamps supported by ballast American Ballast 29

32 Ballast Specification Guide 30 american BALLAST cross reference guide American Ballast Advance Universal Osram Howard Application AB1-32-IP-UNV ICN-1P32-SC B132IUNVHP-B QTP1X32T8/UNV-SC EP1/32IS/ Lamp 32/25/17WT8 Multi Voltage THD<10% AB2-32-IP-UNV ICN-2P32-SC B232IUNVHP-B QTP2X32T8/UNV-SC EP2/32IS/ OR 1 Lamp 32/25/17WT8 Multi Voltage THD<10% AB3-32-IP-UNV ICN-3P32-SC B332IUNVHP-A QTP3X32T8/UNV-SC EP3/32IS/ OR 2 Lamp 32/25/17WT8 Multi Voltage THD <10% AB4-32-IP-UNV ICN-4P32-SC B432IUNVHP-A QTP4X32T8/UNV-SC EP4/32IS/ OR 3 Lamp 32/25/17WT8 Multi Voltage THD <10% AB1-32-IP-120 REL-1P32-SC B132I120RH-A QT1X32/120IS-SC E1/32/IS Lamp 32/25/17WT8<20% THD AB2-32-IP-120 REL-2P32-SC B232I120RH-A QT2X32/120IS-SC E2/32IS OR 1 Lamp 32/25/17WT8<20% THD AB3-32-IP-120 REL-3P32-SC B332I120RH-A QT3X32/120IS-SC E3/32IS OR 2 Lamp 32/25/17WT8 THD<20% AB4-32-IP-120 REL-4P32-SC B432I120RH-A QT4X32/120IS-SC E4/32IS OR 3 Lamp 32/25/17WT8 THD<20% AB1-32-IP-277 VEL-1P32-SC B132I277RH-A QT1X32/277IS-SC E1/32/IS Lamp 32/25/17WT8 THD<20% AB2-32-IP-277 VEL-2P32-SC B232I1277RH-A QT2X32/277IS-SC E2/32IS OR 1 Lamp 32/25/17WT8 THD<20% AB3-32-IP-277 VEL-3P32-SC B332I277RH-A QT3X32/277IS-SC E3/32IS OR 2 Lamp 32/25/17WT8 THD<20% AB4-32-IP-277 VEL-4P32-SC B432I277RH-A QT4X32/277IS-SC E4/32IS OR 3 Lamp 32/25/17WT8 THD<20% AB2-59-IP-UNV REL-2P59 B259I120H QT2X59/120IS-SC E2/59IS OR 1 Lamp F96T8 AB2-59-IP-UNV VEL-2P59 B259I2770H QT2X59/277IS-SC E2/59IS OR 1 Lamp F96T8 AB2-59-IP-UNV IOP-2P59-SC NA QT2X59/277IS-SC E2/59IS OR 1 Lamp F96T8 AB1-32-IP-UNV-HE IOPA-1P32-SC B132IUNVHE-A QHE1X32T8/UNV ISN-SC EP2/32IS/MV/SC/HE 1 Lamp 120/277V 32/25/17W T8 NEMA Premium AB2-32-IP-UNV-HE IOPA-2P32-SC B232IUNVHE-A QHE2X32T8/UNV ISN-SC EP2/32IS/MV/SC/HE 2 Lamp 120/277V 32/25/17W T8 NEMA Premium AB3-32-IP-UNV-HE IOPA-3P32-SC B332IUNVHE-A QHE3X32T8/UNV ISN-SC EP3/32IS/MV/SC/HE 3 Lamp 120/277V 32/25/17W T8 NEMA Premium AB4-32-IP-UNV-HE IOPA-4P32-SC B432IUNVHE-A QHE4X32T8/UNV ISN-SC EP4/32IS/MV/SC/HE 4 Lamp 120/277V 32/25/17W T8 NEMA Premium AB1-32-PS-UNV IOP-1S32-SC B132IUNVHP-A QTP1X32T8/UNV PSN-TC EP2/32PRS/MV/MC/HE 1 Lamp 120/277V 32/25/17W T8 <10%THD AB2-32-PS-UNV IOP-2S32-SC B232IUNVHP-A QTP2X32T8/UNV PSN-TC EP2/32PRS/MV/MC/HE 2 Lamp 120/277V 32/25/17W T8 <10%THD AB3-32-PS-UNV IOP-3S32-SC B332IUNVHP-A QTP3X32T8/UNV PSN-TC NA 3 Lamp 120/277V 32/25/17W T8 <10%THD AB4-32-PS-UNV IOP-4S32-SC B432IUNVHP-A QTP4X32T8/UNV PSN-TC NA 4 Lamp 120/277V 32/25/17W T8 <10%THD AB2-32-IP-UNV-L REL-2P32-LW-RH-TP B232I120L QT2X32/120LP EL2/32IS OR 1 Lamp 32/25/17WT8<20% THD AB3-32-IP-UNV-L REL-3P32-LW-RH-TP B332I120L QT3X32/120LP EL3/32IS OR 2 Lamp 32/25/17WT8 THD<20% AB4-32-IP-UNV-L REL-4P32-LW-RH-TP B432I120L QT4X32/120LP EL4/32IS OR 3 Lamp 32/25/17WT8 THD<20% AB2-32-IP-UNV-L VEL-2P32-LW-RH-TP B232I277L QT2X32/277LP EL2/32IS OR 1 Lamp 32/25/17WT8<20% THD AB3-32-IP-UNV-L VEL-3P32-LW-RH-TP B332IS277L QT3X32/277LP EL3/32IS OR 2 Lamp 32/25/17WT8 THD<20% AB4-32-IP-UNV-L VEL4P32-LW-RH-TP B432I277L QT4X32/277LP EL4/32IS OR 3 Lamp 32/25/17WT8 THD<20% AB2-32-IP-120-HX AB2-32-IP-277-HX AB3-32-IP-120-HX AB3-32-IP-277-HX REL-2P32-HL- RH-TP VEL-2P32-HL- RH-TP REL-3P32-HL- RH-TP VEL-3P32-HL- RH-TP B232I120RHH QT2X32/IS/120PLUS EH2/32IS OR 1 Lamp 32/25/17WT8<20% THD 1.18 BF B232I277RHH QT2X32/IS/277PLUS EH2/32IS OR 1 Lamp 32/25/17WT8<20% THD 1.18 BF B332I120RHH QT3X32/IS/120PLUS EH3/32IS OR 2 Lamp 32/25/17WT8<20% THD 1.18 BF B332I277RHH QT3X32/IS/277PLUS EH3/32IS OR 2 Lamp 32/25/17WT8<20% THD 1.18 BF AB1-25-RP-120 NA NA NA NA Rapid Start 1 Lamp 25/17WT8 (THD<200%) ( PF >.5) AB1-32-RS-120 NA NA NA NA Rapid Start 1 Lamp 32/25WT8 (THD<200%) ( PF >.5) AB2-32-IP-120-R REB-2P32-SC B232I120RES- A AB4-32-IP-120-R REB-4P32-SC B432I120RES- A QTR2X32T8/120 ISN-SC NA 2 OR 1 Lamp 32/25/17WT8 (THD<200%) ( PF >.5) QTR4X32T8/120 ISN-SC NA 4 OR 3 Lamp 32/25/17WT8 (THD<200%) ( PF >.5) AB2-40-RS-120 REL2S40-SC B240R120HP QTP2x40T12/120RSN-B E2/40/RS Lamp 40/34W T12 AB1-40-RS-277 VEL1S40-SC B140R277HP QTP1x40T12/277RSN-B NA 1 Lamp 40/34W T12 AB2-40-RS-277 VEL2S40-SC B240R277HP QTP2x40T12/277RSN-B E2/40/RS Lamp 40/34W T12 AB2-96-IP-120 REL-2P60 B260I120RH QT2x96/120IS E2/75IS or 1 lamp 96T12W AB2-96HO-RS-120 REL-2S110 B295SR120HP QT2x96/120HO E2/110RS or 1 lamp 96T12HOW AB2-96HO-RS-UNV NA B295SRUNVHP NA NA AB2-96-IP-277 VEL-2P60 B260I277RH QT2x96/277IS E2/75IS or 1 lamp 96T12W AB2-96HO-RS-277 VEL-2S110 B295SR277HP QT2x96/277HO E2/110RS or 1 lamp 96T12HOW

33 American Ballast Advance Universal Osram Howard Application AB2-40-RS-120-R RELB-2S40-SC B240R120RH NA NA 2 OR 1 Lamp 40/34WT12 (THD<200%) ( PF >.5) AB1-13-PP-120 NA NA NA NA 1 Lamp 13WT5 (THD<200%) ( PF >.5) EOL ballast shutdown AB2-13-PP-120 NA NA NA NA 2 Lamp 13WT5 (THD<200%) ( PF >.5) EOL ballast shutdown AB2-28-PS-UNV ICN-2S28 B228PUNV-C QT2x28/120 or 277PS NA 2 Lamp: 28/21/14WT5: Program Start AB2-54-PS-UNV ICN-2S54 B254PUNV-D QTP2x54T5HOUNVNL EP2/54HO/PRS/MV 2 Lamp: 54WT5HO: Program Start AB4-54-PS-UNV ICN-4S54 B454PUNV-D QTP4x54T5HOUNVNL NA 4 or 3 Lamp 54WT5HO: Program Start AB2-40-PS-UNV-BX ICF-2S42 C240PUNVHP-B QTP1x40TT5/120 or 277 PSN-F EP1/40ISTT/ OR 1 Lamp 40W BIAX: Program Start AB2-13-PS-UNV ICF-2S13 C213UNVBE QTP 1/2X13CF/UNV EP2/13CF/MV 2 OR 1 Lamp CFQ13/CFS10/CFS16W AB2-18-PS-UNV ICF-2S18 C218UNVBE QTP 1/2X18CF/UNV EP2/18CF/MV 2 OR 1 Lamp CFQ18W & CFTR18W AB2-26-PS-UNV ICF-2S26 C2642UNV QTP 1X26/32/42/UNV EP2/26CF/MV (2/I) CFQ26W/CFTR26W OR (I), CFTR32W, & CFTR42W AB2-42-PS-UNV ICF-2S42 C2642UNV QTP 2X26/32/42/UNV EP2/42CF/MV (2/1) CFQ26W/CFTR26W, CFTR32W, OR CFTR42W Ballast Specification Guide 31

34 Ballast Specification Guide 32 Glossary of Terms ANSI (American National Standards Institute): Non-profit organization that generates voluntary product performance standards for many U.S. industries. ANSI Standard C82.1 applies to electromagnetic ballast; ANSI Standard C82.11 applies to electronic ballast. Auto-Restart Capability: Eliminates the need to reset main power after failed lamps are replaced. Burned out lamps can be replaced without disconnection power to the ballast. Ballast Cycling: Undesirable condition under which the ballast turns lamps on and off (cycles) due to the overheating of the thermal switch inside the ballast. This may be due to incorrect lamps, improper voltage being supplied, high ambient temperature around the fixture, or the early stage of ballast failure. Ballast Efficacy Factor (BEF): Value used to evaluate various lighting systems based upon light output and power input. Mathematical formula: Ballast Efficacy Factor equals Ballast Factor (percent value) divided by ballast Input Power (watts). Ballast Factor (BF): Measure of light output from lamp operated by commercial ballast, as compared to laboratory standard reference ballast. Ballast factor.90 means ballast produces 90% of light produced by ANSI C82.2 reference ballast operating same lamps. Canadian Standards Association (CSA): Group that generates product performance and/or safety standards for many Canadian Industries. Crest Factor (Lamp Current Crest Factor): Ratio of peak lamp current to RMS or average lamp operating current. This measurement measures how perfect the sinusoid is. Example if the peak current divided by RMS current will equal for a perfect sin wave current without any peaks or imperfections. ANSI requires that the lamp current CF must be less than 1.7. Efficacy: Lumen output per unit of power supplied to ballast (lumens per watt). EMI (Electromagnetic Interference): Electrical interference ( noise ) generated by electrical and electronic devices. Levels generated by high frequency electronic devices are subject to regulation by Federal Communications Commission (FCC). Electrical Testing Laboratory (ETL): Independent electrical testing laboratory that performs ballast tests and certifies accuracy of performance data. EOL End of Life Shutdown Circuitry: As the lamp ages the cathodes of the lamp will degrade based upon chemical and/or electrical actions within the lamp and the lamp itself. This may cause excessive heat within the lamp with could result in rupturing the glass. T5 and smaller diameter lamps require EOL circuitry as a function of the ballast. FCC Regulations: Legally enforceable U.S. government standards for EMI and FRI that must be met by high frequency electronic devices used in U.S. for Class A (industrial) and Class B (residential) applications. Frequency: Rate of alternation in an AC current. Expressed in cycles per second or Hertz (Hz). Harmonic Distortion: Distortion of an AC waveform caused by multiples of the fundamental frequency (harmonics). Odd triplet harmonics (thirds, ninths, etc.) may result in large currents on the neutral line in a four-wire Wye threephase system. Harmonics: Refers to components of the overall frequency, an integral multiple of the fundamental sine wave frequency. Hertz (Hz): Unit used to measure frequency (cycles per second) of alternating current or voltage. Input Voltage: Voltage, provided by a power line or power supply, to the ballast or driver. Input watts total power input to the ballast that includes lamp watts and ballast losses. Inrush Current: A transient condition that occurs during ballast start-up. Instant Start: Lamp starting method in which lamps are started by high voltage input with no preheating of lamp cathodes. Lamp Flicker: Rapid visible light change occurring in fluorescent lighting systems. Parallel Lamp Circuit: Ballast circuit in which the lamps connected to one ballast operate independently of one another if one lamp fails, the rest remain lit. Potting: Material used to fill the cases of electromagnetic and electronic ballasts to dampen sound, protect from moisture, improve head removal and increase reliability. Power Factor PF: A measurement of how efficiently an electrical device uses power supplied by the power lines. PF Watts / (volts x Amps). Programmed Start Ballast: An electronic lighting circuit similar to rapid start that provides precise heating of the lamp filaments and tightly controlling the preheat duration before applying starting voltage to ignite the lamp. NOM (Normas Oficial Mexicana): Laboratory that sets safety standards for building materials, electrical appliances and other products for Mexico. Series Circuit: Ballast circuit in which the lamps connected to one ballast operate as a group. If one lamp fails or is removed, then all lamps in the circuit turn off. Series-Parallel Circuit: Ballast circuit in which the lamps connected to one ballast operate both as a group and independently. If one lamp fails or is removed in the series connected section, then all lamps in that section will turn off, but the lamps in the parallel circuit remain on. Universal Voltage (UNV): Provides the most cost effective options when reviewing total cost of material management. You are assured to have the correct voltage for any of the most common commercial voltages used in the United States. Ballast instantly identify the supply voltage, and then adjusts the starting and operation mode to accommodate. Voltage ranges from 108~305 volt are all easily and instantly accommodated. UL (Underwriters Laboratories, Inc.): A non profit organization in the US that generates product performance and safety standards for electrical equipment, building materials, and other products. End use products such as lighting fixtures, fully encased ballast, and home appliances are examples of UL Listed products and bear the UL Logo.

35 Warranty Electronic Fluorescent Ballast Warranty American Ballast warrants to the purchaser that its products will be free from defect in material and workmanship and will be of the designated kind and quality for a period of five (5) years from the date of manufacture by American Ballast. This warranty is not applicable to any ballast manufactured by American Ballast which is not installed and operated in accordance with the current edition of the National Electric Code (NEC), all applicable state and local codes, and Underwriters Laboratories, Inc. (UL) standards for safety. This warranty also is not applicable to any electronic ballast not installed and operated in accordance with all applicable American National Standards Institute (ANSI), and American Ballast s instructions for installation (including, but not limited to, approved OUTDOOR installations) or to any ballast which has been subjected to abnormal operating conditions including, but not limited to, case temperatures that exceed the maximum level as listed on the ballast label. Ballast Specification Guide If it appears within five (5) years from the date of manufacture by American Ballast that any ballast does not meet the warranty specified above, the purchaser must notify American Ballast, by calling or , of its warranty claim and, after receiving proper authorization, return the product(s) to American Ballast. Within thirty (30) days of receipt, American Ballast shall correct any defects at American Ballast s expense and, at American Ballast s option; said correction of defect shall be made either by (a) repairing any defective part or parts by making available a repaired part or product, or (b) replacing any defective part or parts by making available a replacement part or product. In addition, American Ballast shall pay a U.S. $10.00 labor allowance for each American Ballast electronic ballast found to be defective after proper installation. LIMITATIONS OF LIABILITY: (a) SELLER WILL NOT UNDER ANY CIRCUMSTANCES, WHETHER AS A RESULT OF BREACH OF CONTRACT, BREACH OF WARRANTY, TORT OR OTHERWISE BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES including, but not limited to, loss of profits or revenues, loss of use of or damage to any associated equipment, cost of capital, cost of substitute products, facilities or services, downtime costs, or claims of purchaser s customers; (b) SELLER S LIABILITY ON ANY CLAIM OF ANY KIND FOR ANY LOSS OR DAMAGE ARISING OUT OF, RESULTING FROM, OR CONCERNING ANY ASPECT OF THIS AGREEMENT OR FROM THE PRODUCTS OR SERVICES FURNISHED HEREUNDER SHALL NOT EXCEED THE PRICE OF THE SPECIFIC ORDER WHICH GIVES RISE TO THE CLAIM. This Warranty is designated a LIMITED WARRANTY pursuant to the Federal Consumer Product Warranties Act. This Warranty is in lieu of all other warranties whether statutory, express, implied, written or oral, including implied warranties of merchantability, suitability or fitness for particular purpose and except as specifically set forth above, no other warranties of any kind, statutory or otherwise are herein expressed. 33

36 Ballast Specification Guide Wiring Diagrams 34

37 Wiring Diagrams Ballast Specification Guide 35

38 Ballast Specification Guide Wiring Diagrams 36

39 Wiring Diagrams Ballast Specification Guide 37

40 Ballast Specification Guide Wiring Diagrams WIRING DIAGRAM QQ CAP 1 red lead for 3 lamp operation WIRING DIAGRAM SS CAP yellow/black leads for 3 lamp operation 38

41 CAN Dimensions Ballast Specification Guide 39

42 Ballast Specification Guide CAN Dimensions 40

43 notes Ballast Specification Guide Corporate Office: Engineering Office Fremont Blvd. 900 Western America Circle, Suite 205 Fremont, CA Mobile, AL Phone: Phone: Fax: Fax:

44 Corporate Office Fremont Blvd. Fremont, CA Tel: Fax: Engineering Office 900 Western America Circle Suite 205 Mobile, AL Tel: Fax: China Office No. 357 Jinfeng Rd. New District Syzhou Jiangsu , China Tel: Fax: Copyright 2009 American Ballast

Reduce Maintenance Costs *

Reduce Maintenance Costs * Reduce Maintenance Costs * Philips Advance programmed start parallel Optanium ballasts for T8 lamps helps lower maintenance costs with independent lamp operation. Philips Advance Optanium high-efficiency

More information

Optanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS:

Optanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS: Optanium High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps P R O D U C T O V E R V I E W : Advance expands a new family of Smart Solutions for T8 lighting systems Optanium.

More information

ICN2S40N35I Ele Ballast (2) F40T V

ICN2S40N35I Ele Ballast (2) F40T V 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ICN2S40N35I Ele Ballast (2) F40T12 120-277V Philips Advance Catalog Number Manufacturer Description Weight per unit Product

More information

High performance for high ceilings

High performance for high ceilings High performance for high ceilings Philips Advance Optanium programmed start parallel ballasts for T5HO and T8 lamps offers improved efficiency-saving on both energy and maintenance costs. Our new addition

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-2T42-M5-BS@120 Lamp Type Num. of Lamps Rated Lamp Watts M Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor CFTR32W/GX24Q 2

More information

Electronic Fluorescent Ballasts

Electronic Fluorescent Ballasts Electronic Fluorescent Ballasts A Complete Range of Solutions From The Name You Trust For more than 30 years, the lighting industry has relied on our TRIAD brand for the most specified, most installed,

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-4PSP32-G@120V Input Voltage 120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT3PSP32SC@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor F17T8 3 17 50/10

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-128-D@120V Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor F14T5 1 14 50/10

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-2S26-M5-BS@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor CFQ13W/G24Q 1

More information

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps T5 versus T8 Fluorescent Lamps The good, the bad, & the ugly about T8 and T5 lamps Association of Energy Engineers- Cleveland Chapter Tuesday, February 22, 2005 Presented by: Lewis S. Sternberg, LC Consultants

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-2S32-SC@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor F17T8 2 17 50/10

More information

RELB2S40N35I (2)F40T12 120V Ele BLST

RELB2S40N35I (2)F40T12 120V Ele BLST 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RELB2S40N35I (2)F40T12 120V Ele BLST Philips Advance Catalog Number Manufacturer Description Weight per unit Product Category

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) ICN-2S28-T@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest F14T5 1 14 0/-18 0.14 17 1.07

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-4PSP32-G@120V Input Voltage 120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor

More information

QUICKTRONIC ICE Universal Voltage Systems

QUICKTRONIC ICE Universal Voltage Systems QUICKTRONIC ICE Universal Voltage Systems Electrodeless Fluorescent Systems Lamp / Ballast Guide lamp: ICE 40W QT1x40ICE/UNV lamp: ICE 70W QT1x100ICE/UNV lamps: ICE 100W QT1x100ICE/UNV QT1x150ICE/UNV lamp:

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) ICN-2S54-90C-T@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest F54T5/HO 1 54-20/-29 0.53

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) Electrical Specifications HCN4S5490C2LSG@347 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 347 Input Frequency 50/60 HZ Status

More information

Performance and Efficiency

Performance and Efficiency Electronic Fluorescent Quick Guide 347V Applications Fluorescent Solutions Performance and Efficiency Electronic Fluorescent Ballasts for 347V Applications Quick Guide Contents Electronic Fluorescent Ballasts

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) ICF-2S42-M2-BS@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest * CFQ26W/G24Q 2 26 0/-18

More information

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies Bob Trate - CPMR Philips/Advance Ballasts April 20, 2010 Fluorescent Ballast Overview There are several generations and design

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) Electrical Specifications ICN4S5490C2LSG@120 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 120-277 Input Frequency 50/60 HZ

More information

The sustainable choice. Optanium high-efficiency ballasts for today s T8 lighting needs

The sustainable choice. Optanium high-efficiency ballasts for today s T8 lighting needs The sustainable choice Optanium high-efficiency ballasts for today s T8 lighting needs A renewed focus on energy Across the country today, businesses are taking a much closer look at ways to conserve energy

More information

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps 3-Wire Control, 220/240 Volt T-8 Linear, rev hi-220-240-1b 1.10.02 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) HOT DIMMED HOT NEUTRAL Hi-lume Power Control Dimming Ballast Lamps DESCRIPTION Continuous,

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing

More information

EcoSystemR Multiple Control Input Ballasts

EcoSystemR Multiple Control Input Ballasts EcoR Multiple Control s 369454h 1 09.15.14 Digital electronic dimming ballasts maximize the benefits of a lighting management system. EcoR s offer 100% to 10% dimming; ideal for use where saving energy,

More information

INSTANT START BALLASTS

INSTANT START BALLASTS ULTRAMAX INSTANT START BALLASTS GE Consumer & Industrial TRANSFORMING THE POWER OF LIGHT Take Energy Savings to the MAX with Take Energy Savings to the MAX with High Efficiency Electronic Ballasts NEW

More information

VEL2P75S35I 2-F96T12 277V Electronic Ballast

VEL2P75S35I 2-F96T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2P75S35I 2-F96T12 277V Electronic Ballast Philips Advance Catalog Number VEL2P75S35I Manufacturer Philips Advance Description

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS Overview Just as electronic ballast technology enhanced fluorescent lighting systems, electronic HID ballasts bring significant performance improvements to HID lighting systems: Higher efficiency Greater

More information

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

VEL2S40SC35I 2 F34T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2S40SC35I 2 F34T12 277V Electronic Ballast Philips Advance Catalog VEL2S40SC35I Manufacturer Philips Advance Description

More information

Ballast Technology & Specification Guide SYLVANIA QUICKTRONIC Electronic Ballasts

Ballast Technology & Specification Guide SYLVANIA QUICKTRONIC Electronic Ballasts Ballast Technology & Specification Guide SYLVANIA QUICKTRONIC Electronic Ballasts SEE THE WORLD IN A NEW LIGHT OSRAM SYLVANIA, the global leader in lighting systems, is committed to providing ballasts

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Five Control Digital Dimming s Eco Multiple Control s 369454l 1 09.02.16 Digital electronic dimming ballasts maximize the benefits of a lighting management system. Eco s offer 100% to 10% dimming;

More information

RZT2S54 Electr DMMG Ballast

RZT2S54 Electr DMMG Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RZT2S54 Electr DMMG Ballast Philips Advance Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts AmbiStar SmartMate Standard T5HO PureVOLT 1 Lighting s Atlas -11 ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts Fluorescent allasts - - High-efficiency

More information

1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps

1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps s easy as 1,2,3... Mark 10 Powerline immable allasts Listed 704G Philips dvance Mark 10 Powerline immable allasts make converting your existing fixtures easy. For companies looking to make their fixed-output

More information

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts TVE Overview Eco-0TM TVETM 0% TVE () 02.9.04 The (Eco-0) TVE is a 0% fluorescent dimming ballast for applications using a 0-0V control. TVE ballasts are also designed to work seamlessly with 0-0V lighting

More information

Table of Contents T8 Instant Start Ballasts

Table of Contents T8 Instant Start Ballasts Table of Contents T8 Instant Start Ballasts gelighting.com Ballasts Understanding T8 Fluorescent Ballasts...10-2 Understanding Fluorescent Systems...10-3 Fluorescent Ballast Application Notes...10-5 UltraMax

More information

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube 3-Wire Control, 120, 277 Volt, T4 Quad Tube and T4 Triple Tube rev hi-compact-1a 3.7.01 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) T4 - One Lamp 3.00 w (76mm) x 1.00 h (25mm) x4.90 l (124mm) T4 - Two

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Optanium mbistar SmartMate Standard T5HO PureVOLT 1 ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Fluorescent allasts - - Optanium High-efficiency electronic

More information

Lighting Tables for New Equipment 3/9/2016

Lighting Tables for New Equipment 3/9/2016 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts (Fixtures or lamps with integrated occupancy sensors may be eligible for an additional sensor rebate - see page 7) LENGTH DESCRIPTION

More information

Compact SE Overview. High-Performance Dimming. Ballast

Compact SE Overview. High-Performance Dimming. Ballast Compact SE Overview CompactSE 01.10.10 For designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your solution.

More information

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ICN3P32SC35I 3-F32T8 120/277V Electronic Philips Advance Manufacturer Description Weight per unit Product Category Features

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Optanium mbistar SmartMate Standard T5HO PureVOLT 1 ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Fluorescent allasts - - Optanium High-efficiency electronic

More information

Lighting Tables for New Equipment 2/24/2015

Lighting Tables for New Equipment 2/24/2015 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00 --- --- 2 32 207 11.00 --- --- 3 48 208 18.00 --- --- 4 57 209 18.00 --- ---

More information

HIGH FREQUENCY ELECTRONIC BALLASTS

HIGH FREQUENCY ELECTRONIC BALLASTS HIGH FREQUENCY S Introduction High efficiency, high frequency electronic ballasts offer enhanced lighting performance and energy savings. The Electric Research Institute estimates that lighting consumes

More information

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 EC3DT4MWKU1S 26/32W T4 1LMP Ba Lutron Catalog Number Manufacturer Description Weight per unit Product Category EC3DT4MWKU1S

More information

Distribution Restriction Statement Approved for public release; distribution is unlimited.

Distribution Restriction Statement Approved for public release; distribution is unlimited. CEMP-ET Engineer Technical Letter 1110-3-441 Department of the Army U.S. Army Corps of Engineers Washington, DC 20314-1000 Engineering and Design ELECTRONIC BALLASTS FOR FLUORESCENT LIGHTING FIXTURES ETL

More information

The power behind today s lighting designs

The power behind today s lighting designs The power behind today s lighting designs Electronic HID: Driving performance in specification Unlocking the performance potential Electronic high intensity discharge (ehid) lighting is becoming an increasingly

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS ELECTRONIC HID BALLASTS Precision. Perfect Light. Remote Transformers Linear Fluorescents Sign Ballasts Electronic HID LED Drivers Electronic HID Ballasts Electronic HID ballasts have been designed from

More information

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor Heavy industrial LED lighting Champ Pro PFM LED luminaires Champ PFM LED floodlights for heavy industrial areas Authorized Distributor Champ Pro PFM LED floodlights Safe. Reliable. Efficient. Featuring

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS ELECTRONIC HID BALLASTS Precision Power. Perfect Light. Ballasts, Drivers, Transformers & Lamps For All Lighting Applications Electronic HID Ballasts Hatch Electronic HID ballasts have been designed from

More information

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps Reliability with the most essential intellect Philips HF-Essential Electronic ballasts for TL5 lamps HF-Essential - Reliability with the most essential intellect Electronic ballasts for TL5 lamps The cost-saving

More information

Lighting Tables for New Equipment 1/1/2018

Lighting Tables for New Equipment 1/1/2018 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts - REBATES are 50% of fixture/lamp cost, up to maximum amounts shown below LAMP LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00

More information

TRUET5 EXT (DIMMABLE)

TRUET5 EXT (DIMMABLE) t all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. TRUET5 EXT (DIMMABLE) www.trulygreensolutions.com

More information

Compact SE Overview. High-Performance Dimming. Ballast

Compact SE Overview. High-Performance Dimming. Ballast allast Compact SE Overview CompactSE- 03.08.04 or designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your

More information

work 2013 Lighting Rebate New equipment & construction Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note:

work 2013 Lighting Rebate New equipment & construction Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note: Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note: 1. This application is for new high efficiency lighting fixtures, systems and controls. 2. Cut sheets/specifications including

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS Ordering Information How to Order Philips Lighting has developed the industry s broadest distribution system for electronic ballasts. More than 000 stocking distributors nationwide. For information on

More information

FDBT S 32W120V DM Bal

FDBT S 32W120V DM Bal 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-794 ax: 936-560-4685 llenwatson@elliottelectric.com DT430S 3W0V DM al Catalog Number Manufacturer Description Weight per unit Product Category

More information

THE HEARTBEAT B E H I N D T H E HEARTBEAT MEDICAL POWER BROCHURE

THE HEARTBEAT B E H I N D T H E HEARTBEAT MEDICAL POWER BROCHURE THE HEARTBEAT B E H I N D T H E HEARTBEAT MEDICAL BROCHURE A B O U T EOS P O W E R EOS Power has been designing standard, modified and custom medical power solutions for the global medical market for

More information

MMagneTek ELECI RONIC FLUORESCENT BALLAST R'!AiB Tria d ' loiiiiiitrlllll-..lhod Now'lodloologv. Univefsal Voltage.

MMagneTek ELECI RONIC FLUORESCENT BALLAST R'!AiB Tria d ' loiiiiiitrlllll-..lhod Now'lodloologv. Univefsal Voltage. ELECI RONIC FLUORESCENT BALLA MATRIX Lamp Type "R" educed "H" armonic (THO< 20%) Low Profile Oly Voltage Instant Start Standard can Programmed Rapid Instant Start Start AccuStartTM Univefsal Voltage Low

More information

Linear Line Voltage LED Engine

Linear Line Voltage LED Engine Linear Line Voltage LED Engine Product Specification Introduction The TERRALUX Linear LED Engine is a fully integrated, self-contained, plug-and-play LED solution for lighting fixture manufacturers and

More information

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B 150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B Part #: HBLP-REMG-1MLED-B-PND Page: 1 Made in Texas The Larson Electronics HBLP-REMG-1MLED-B-PND LED

More information

Lighting Tables for Existing/Base Equipment 1/1/2014

Lighting Tables for Existing/Base Equipment 1/1/2014 T12 Fluorescent Lamps and Fixtures LENGTH Lighting Tables for Existing/Base Equipment OF CODE WATTS LENGTH OF CODE WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS ELECTRONIC HID S CONTENTS 228 229 229 230 23 How to Read a Table Ceramic Discharge Metal Halide Ballasts Dimensions and Wiring Diagrams Cross Reference Guide Specifications HOW TO READ AN ELECTRONIC HID

More information

2001 TMT Associates 1

2001 TMT Associates 1 Emerging Lighting Technologies Thomas M. Tolen, LC IEEE 3/21/01 TMT Associates, 2001 1 Overview New Lighting Technologies AB970 and The Crisis New Title 24 IEEE 3/21/01 TMT Associates, 2001 2 New Lighting

More information

31 SERIES Modular area fixtures. Replaces: 1000W HID

31 SERIES Modular area fixtures. Replaces: 1000W HID Replaces: 1000W HID Product Life: 75,000 hours Optic Lens: Borosilicate Glass 31 SERIES Modular area fixtures Neptun's LED parking lot /area fixtures combine architectural form and versatility to make

More information

Emerging Lighting Technologies IEEE - March 21, 2001

Emerging Lighting Technologies IEEE - March 21, 2001 Emerging Lighting Technologies Thomas M. Tolen, LC Overview New Lighting Technologies AB970 and The Crisis New Title 24 IEEE 3/21/01 TMT Associates, 2001 1 IEEE 3/21/01 TMT Associates, 2001 2 New Lighting

More information

L I G H T W A V UV Electronic Ballast E 2010

L I G H T W A V UV Electronic Ballast E 2010 L I G H T W A V UV Electronic Ballast 2010 E LIGHTWAVE High Frequency Electronic Ballast Function of an UV ballast To provide the proper voltage and current such that a steady plasma can be established

More information

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming cosystem Hi-lume % rchitectural imming Hi-lume Overview 369-398c 06.04. Hi-lume architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. y providing industry

More information

ICETRON ECOLOGIC Inductively Coupled Fluorescent System

ICETRON ECOLOGIC Inductively Coupled Fluorescent System www.sylvania.com ICETRON ECOLOGIC Inductively Coupled Fluorescent System Key Features & Benefits Unparalleled lamp life 100,000 hour life 10 years of continuous operation White light 3500K, 4100K, 5000K

More information

High Bay Lighting Solutions. Energy Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting

High Bay Lighting Solutions. Energy Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting High Bay Lighting Solutions WORKING INSTANTLY, QUIETLY FOR REMARKABLE ENERGY SAVINGS Universal Lighting Technologies

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

www.greenelectricalsupply.com Dimensions not to scale 4.4 Width 6.75 ; with latches 7.33 2 ; 27.68 4 ; 51.65 8 ; 100 Lengths, nominal; actual AVAILABLE Simkar is proud to offer fixtures that comply to

More information

2 LED Designer Series

2 LED Designer Series LED Designer Series When appearance is most important, TCP s LED Designer Series turns any location into something truly exceptional. Limitless options for the following applications: Offices Restaurants

More information

ECO EXT (DIMMABLE)

ECO EXT (DIMMABLE) Not all products are qualified on the DLC QPL. To view our DLC qualified products, please consult the DLC Qualified Products List at www.designlights.org/qpl. ECO EXT (DIMMABLE) www.trulygreensolutions.com

More information

RPS TL-UL System. Solutions for the North American Solar Market

RPS TL-UL System. Solutions for the North American Solar Market RPS TL-UL System Solutions for the North American Solar Market 2015/2016 Power, control and green solutions 3 RPS TL-UL System Photovoltaics is now offering the ULcertified RPS TL inverter series. Leveraging

More information

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications LED lighting for drilling & marine Pauluhn ZPL LED luminaires Pauluhn ZPL LED luminaires for drilling & marine applications Pauluhn ZPL explosionproof LEDs Safe. Reliable. Efficient. Featuring the industry's

More information

56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications Lumens - IP67 Waterproof

56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications Lumens - IP67 Waterproof 56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications - 7000 Lumens - IP67 Waterproof Part #: GVP-48-2L-LED Page: 1 The Larson Electronics GVP-48-2L-LED is similar to our popular explosion proof

More information

Brakes, Clutches & SINPAC SolidState Switches

Brakes, Clutches & SINPAC SolidState Switches Product Line Overview Effective Date: 9/13/2018 Brakes, Clutches & SINPAC SolidState Switches About Us Stearns Brakes Set the Standard for Excellence Our Value To You Stearns is the market leader in providing

More information

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware 14W Linear 2' LED Light - 1750 Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware Part #: WDL-24-1L-SS-2X5FT Page: 1 Made in Texas Providing 1,750 lumens of clean, crisp white light

More information

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast IZT2S32SC 2 Lamp 32/T8 immable Ballast Philips Advance Catalog Number Manufacturer escription Weight per unit Product Category IZT2S32SC Philips Advance Electronic Ballast, High Frequency; Programmed Start;

More information

LED Flat Panel Luminaires

LED Flat Panel Luminaires LED Flat Panel Luminaires Great Features/Benefits TCP s LED Flat Panel Luminaires feature a slim, low-profile design with full panel diffusion and superior uniformity. These DLC Premium listed flat panels

More information

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System STL Series Emergency Lighting Inverter 3kW to 160kW Central System STL Series Sine Wave APPLICATIONS: The STL Series Inverter will operate incandescent, fluorescent, HID and LED lamps. *Depending on the

More information

Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh

Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh Part #: HALP-48-2L-LED Page: 1 Made in the USA The Larson Electronics HALP-48-2L-LED Hazardous Area

More information

Linear Line Voltage LED Engine

Linear Line Voltage LED Engine Linear Line Voltage LED Engine Product Specification Introduction The TERRALUX Linear LED Engine is a fully integrated, self-contained, plug-and-play LED solution for lighting fixture manufacturers and

More information

Your ideal solution for any lighting project. Well tested, reliable, effective, efficient and long lasting. A Brighter Future with

Your ideal solution for any lighting project. Well tested, reliable, effective, efficient and long lasting. A Brighter Future with Your ideal solution for any lighting project. Well tested, reliable, effective, efficient and long lasting. A Brighter Future with T8 Standard...High efficiency, smaller diameter, energy-saving and long-life

More information

The new standards affecting the lighting industry. Educating you now and into the future.

The new standards affecting the lighting industry. Educating you now and into the future. www.sylvania.com The new standards affecting the lighting industry. Educating you now and into the future. A handy guide to understanding and complying with the new lighting legislation Federal legislation

More information

Venture Lighting Europe Ltd Trinity Court, Batchworth Island Church Street, Rickmansworth Hertfordshire WD3 1RT T: F:

Venture Lighting Europe Ltd Trinity Court, Batchworth Island Church Street, Rickmansworth Hertfordshire WD3 1RT T: F: Venture Lighting Europe Ltd Trinity Court, Batchworth Island Church Street, Rickmansworth Hertfordshire WD3 1RT T: 1923 6926 F: 1923 692659 www.venturelightingeurope.com DOMESTIC REPLACEMENT LAMPS REVISION

More information

LED Strip Light - LED Rail Light Inch LED - 4 Watts Lumen V DC

LED Strip Light - LED Rail Light Inch LED - 4 Watts Lumen V DC LED Strip Light - LED Rail Light - 5.9 Inch LED - 4 Watts - 145 Lumen - 10-30V DC Part #: LEDST-5 Page: 1 Buy American Compliant The LEDST-5 LED Strip Light is designed as an extremely efficient and versatile

More information

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps

Electronic ballasts for fluorescent lamps Multi-lamp ECG. PC T5 PRO-M lp, W T5, T8, compact (CFL) and T5c circular fluorescent lamps T5 T8 TC-F TC-L T5c PC T5 PRO-M lp, 14 80 W T5, T8, compact (CFL) and T5c circular fluorescent lamps Product description Integrated lamp detection Operation of T5 lamps of the same length Average life

More information

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning 156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning Part #: EPL-360-3XLP24-LED-V2-100 Page: 1 Made in Texas The EPL-360-3XLP24-LED-V2-100 Portable Explosion

More information

Section 3- Page --DCL With DEMANDflex Product Overview DemandFlex T DemandFlex T5, T5HO & TT DemandFlex T8 Wiring Diagram...

Section 3- Page --DCL With DEMANDflex Product Overview DemandFlex T DemandFlex T5, T5HO & TT DemandFlex T8 Wiring Diagram... Table of Contents Fluorescent Electromagnetic Ballasts Section 1- Page Product Overview...1-2 Application Operation Information...1-4 Typical Specifications...1-8 Lead Lengths...1-9 T8 (265 ma)...1-10

More information

LED Flat Panel Luminaires

LED Flat Panel Luminaires LED Flat Panel Luminaires 0-347V Great Features/Benefits TCP s LED Flat Panel Luminaire features a slim, low-profile design with full panel diffusion and superior uniformity. It offers a cost effective

More information

150 Watt Street Light - LED Roadway Lighting - 40 LEDs - Multi Voltage - External Bubble Level

150 Watt Street Light - LED Roadway Lighting - 40 LEDs - Multi Voltage - External Bubble Level 150 Watt Street Light - LED Roadway Lighting - 40 LEDs - Multi Voltage - External Bubble Level Part #: RWL-LED-40 The RWL-LED-40 is a 150W LED Roadway Light that provides 13,000 lumen with 40 LEDs. The

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

Energy Solutions LED Accelerator Program

Energy Solutions LED Accelerator Program Energy Solutions LED Accelerator Program Product Qualification Statement I hereby certify that the LED lighting product (Product) listed below meets all applicable general and specific criteria for qualification

More information

LANCE-KASHIAN & COMPANY River Park Plaza Parking Lot Lighting Retrofit Fresno, CA May 21, 2013

LANCE-KASHIAN & COMPANY River Park Plaza Parking Lot Lighting Retrofit Fresno, CA May 21, 2013 LANCE-KASHIAN & COMPANY River Park Plaza Fresno, CA May 21, 2013 Project Overview On May 21 th 2013, USIGT, in conjunction with D5 Enterprises, retrofitted the existing High Pressure Sodium (HPS) parking

More information

REOZM SERIES GENERATORS. for Industrial Power Systems 835 kva 2500 kva 668 kw 2000 kw

REOZM SERIES GENERATORS. for Industrial Power Systems 835 kva 2500 kva 668 kw 2000 kw REOZM SERIES GENERATORS for Industrial Power Systems 835 kva 2500 kva 668 kw 2000 kw For more than 90 years, Kohler has earned a global reputation as a pure power expert in large part to our strict quality

More information

Samsung LED lighting: MR16. Samsung LED lighting: PAR. Energy-saving, cost-effective alternative to halogen lamps in a wide range of applications

Samsung LED lighting: MR16. Samsung LED lighting: PAR. Energy-saving, cost-effective alternative to halogen lamps in a wide range of applications Samsung LED lighting: MR16 Energy-saving, cost-effective alternative to halogen lamps in a wide range of applications Samsung LED lighting: PAR Adjustable, high-performing, low-energy LED lamps Samsung

More information

RS SERIES ROTARY SCREW AIR COMPRESSORS FIXED SPEED ROTARY SCREW AIR COMPRESSORS HP

RS SERIES ROTARY SCREW AIR COMPRESSORS FIXED SPEED ROTARY SCREW AIR COMPRESSORS HP RS SERIES ROTARY SCREW AIR COMPRESSORS FIXED SPEED ROTARY SCREW AIR COMPRESSORS 15 300HP SOME COMPANIES ARE FOUNDED ON HARD WORK. OTHERS ARE FOUNDED ON IDEALS. FS-CURTIS WAS FOUNDED ON BOTH. 1854 1857

More information