Certificate of Compliance

Size: px
Start display at page:

Download "Certificate of Compliance"

Transcription

1 Certificate of Compliance Certificate: (170351) Master Contract: Project: Date Issued: Issued to: Bel Fuse Inc. 206 Van Vorst St Jersey City, New Jersey USA Attention: Editha S. Vergara The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Maggie Lam Maggie Lam PRODUCTS CLASS POWER SUPPLIES-Component Type (CSA nd Ed) CLASS POWER SUPPLIES-Component Type (UL nd Ed) Certified to U.S.Stds Component type power supplies intended for use with Information Technology and Business Equipment, where the suitability of the combination is to be determined by CSA Group. AC/DC Switching Power Supply, Models PFE RA and SPAFFIV-05G, model designation may be followed by suffix SXXX denoting non-safety critical option. Electrical Ratings: Model PFE RA Input rated Vac/ Vdc, A AC/13-9 A DC, Hz; Outputs rated (V1)* 12.3V dc, 244A, (V2) 12V dc, 5A, Total maximum output power shall not exceed 3060 W, 45 C ambient. *Note: V1 output is derated as per the below conditions: 1400 W at Vac, 45 C ambient 2250 W at Vac/ Vdc, 55 C ambient 1050 W at Vac, 55 C ambient DQD 507 Rev Page 1

2 Certificate: Project: Master Contract: Date Issued: Model SPAFFIV-05G Input rated Vac/ Vdc, A AC/13-9 A DC, Hz; Outputs rated (V1)* 12.25V dc, 244A, (V2) 12V dc, 5A, Total maximum output power shall not exceed 3000 W, 45 C ambient. *Note: V1 output is derated as per the below condition: 2250 W at Vac/ Vdc, 55 C ambient APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No , +Am.1:2011 +Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL Information Technology Equipment - Safety - Part 1: General Requirements CONDITIONS OF ACCEPTABILITY 1. This component has been judged on the basis of the required spacings in the Standard for Safety of Information Technology Equipment, CSA/UL , Second Edition +Am. 1 +Am. 2, Sub-clause 2.10, which would cover the component itself if submitted for Listing. 2. The equipment has been evaluated for use in Pollution Degree 2 environment. 3. The Clearance values of the Power Supply Unit (PSU) have been evaluated for an altitude of 4000 m, under IEC : 1992 Table A.2 (altitude correction factor is 1.29). 4. The ground path from the input connector to the PSU case meets protective bonding and has been evaluated at 80 A. 5. The PSU has been evaluated for use in Class I equipment. 6. The secondary outputs of the PSU are SELV. 7. V2 output is non-hazardous energy level. V1 output is at hazardous energy level. 8. The PSU has been evaluated for a TN (Including TN-S and TN-C) and TT systems power source. 9. The PSU has been evaluated for use with a Phase Neutral power source. 10. All Isolating transformers isolation barrier insulation temperatures have been measured within the winding on the insulator. The internal temperature did not exceed the insulation Class limits for NORMAL operation and ABNORMAL operation. 11. The temperature of the Isolating Transformers, T4, T3/T9/T14/T15, T6/T7/T8/T11 isolation barrier shall be assessed in the end application. T4, T3/T9/T14/T15 employ an OBJY3 electrical insulation system designated Class F. Transformers, T6/T7/T8/T11, employs a Class B insulation system. 12. The connector current interruption test (Hot Plugging test) was conducted on the secondary connector of the PSU for 100 cycles. 13. The PSU is not intended for use in vehicles, on board ships or aircraft. 14. The front face of the PSU may be a part of the front of the end product. The front face of the PSU did pass the Impact Test. DQD 507 Rev Page 2

3 Supplement to Certificate of Compliance Certificate: (170351) Master Contract: The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description Product Certification History Update Report to change the EMI capacitors (C7, C16, C17) values AC/DC Switching Power Supply, Models PFE RA and SPAFFIV-05G. (C/US) (transferred from and upgraded to include Am2). DQD 507 Rev Page 1

4 CERTIFICATE No. P Order No Page 1/3 Product Applicant Manufacturer Factory AC/DC or DC/DC Switching Power Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ USA BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District, Shenzhen China See next page(s) Ratings Input: Vac, A, 50-60Hz or Vdc, 13-9A Trade mark Model / Type Ref. PFE RA, PFE3000-S361 Principal characteristics DC Output(s): V1*: 12.3V, 244A: V2: 12V, 5A. Total Maximum Power: 3060 W, 45ºC ambient. The model name may be followed by SXXX indicating nonsafety critical option See next page(s) A sample of the product was tested and found to be in conformity with OFF EN :2006;A11;A1;A12;A2 Validity Additional information This certificate documents conformity with the standards shown, and also applies as license for use of Nemkos name and certification mark. The certificate and license is valid as long as the applicable conditions are complied with, and provided that any changes to the product are notified to Nemko for acceptance prior to implementation. New standards or amendments to the standards may imply that the product design must be updated and/or that re-testing and re-certification is necessary. See next page(s) The abovementioned certified equipment complies with current regulatory requirements regarding electrical safety in Norway and other EU/EEA member states, as far as this can be checked. Compliance with requirements regarding building-in, protection against electric shock and Date of issue Juan Z. Kleppenes Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL FAX info@nemko.com ENTERPRISE NUMBER NO nemko.com

5 CERTIFICATE No. P Order No Page 2/3 Additional model(s) Electromagnetic Compatibility (EMC) must be checked when the equipment is built-in a completed product or forms a part of a complete system. See next page(s) Date of issue Juan Z. Kleppenes Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL FAX info@nemko.com ENTERPRISE NUMBER NO nemko.com

6 CERTIFICATE No. P Order No Page 3/3 Product AC/DC or DC/DC Switching Power Pos. No 1 Model / Type Ref. SPAFFIV-05G Trade mark (if different from page 1) Rating Input: Vac, A, 50-60Hz or Vdc, 13-9A Principal characteristics DC Output(s): V1: 12.25V, 244A; V2: 12V, 5A Total Maximum Power: 3000W 45ºC ambient. The model name may be followed by SXXX indicating non-safety critical option Date of issue Juan Z. Kleppenes Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL FAX info@nemko.com ENTERPRISE NUMBER NO nemko.com

7 Ref. Certif. No. NO88555 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI DACCEPTATION MUTUELLE DE CERTIFICATS DESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la deuxième page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) AC/DC or DC/DC Switching Power Supply Additional information on page 2 Input: Vac, A, 50-60Hz or Vdc, 13-9A Type of Manufacturer s Testing Laboratories used Type de programme du laboratoire d essais constructeur Model / Type Ref. Ref. De type SPAFFIV-05G Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire, peuvent être indiqués sur la deuxième page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport dessais numéro de référence qui constitue partie de ce Certificat DC Output(s): V1: 12.25V, 244A; V2: 12V, 5A Total Maximum Power: 3000W 45ºC ambient. The model name may be followed by SXXX indicating non-safety critical option Additional information on page 2 IEC (ed.2);am1;am This CB Test Certificate is issued by the National Certification Body Ce Certificat dessai OC est établi par l'organisme National de Certification Gaustadalléen 30 NO-0373 Oslo, Norway Date: Signature: Juan Z. Kleppenes Certification Department Issued /1

8 Ref. Certif. No. NO88556 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI DACCEPTATION MUTUELLE DE CERTIFICATS DESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la deuxième page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) AC/DC or DC/DC Switching Power Supply Additional information on page 2 Input: Vac, A, 50-60Hz or Vdc, 13-9A Type of Manufacturer s Testing Laboratories used Type de programme du laboratoire d essais constructeur Model / Type Ref. Ref. De type PFE RA, PFE3000-S361 Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire, peuvent être indiqués sur la deuxième page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport dessais numéro de référence qui constitue partie de ce Certificat DC Output(s): V1*: 12.3V, 244A: V2: 12V, 5A. Total Maximum Power: 3060 W, 45ºC ambient. The model name may be followed by SXXX indicating non-safety critical option Additional information on page 2 IEC (ed.2);am1;am This CB Test Certificate is issued by the National Certification Body Ce Certificat dessai OC est établi par l'organisme National de Certification Gaustadalléen 30 NO-0373 Oslo, Norway Date: Signature: Juan Z. Kleppenes Certification Department Issued /1

9 Ref. Certif. No. NO88556 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI DACCEPTATION MUTUELLE DE CERTIFICATS DESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la deuxième page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) AC/DC or DC/DC Switching Power Supply Additional information on page 2 Input: Vac, A, 50-60Hz or Vdc, 13-9A Type of Manufacturer s Testing Laboratories used Type de programme du laboratoire d essais constructeur Model / Type Ref. Ref. De type PFE RA, PFE3000-S361 Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire, peuvent être indiqués sur la deuxième page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport dessais numéro de référence qui constitue partie de ce Certificat DC Output(s): V1*: 12.3V, 244A: V2: 12V, 5A. Total Maximum Power: 3060 W, 45ºC ambient. The model name may be followed by SXXX indicating non-safety critical option Additional information on page 2 IEC (ed.2);am1;am This CB Test Certificate is issued by the National Certification Body Ce Certificat dessai OC est établi par l'organisme National de Certification Gaustadalléen 30 NO-0373 Oslo, Norway Date: Signature: Juan Z. Kleppenes Certification Department Issued /1

10 Test Report issued under the responsibility of TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Report Number.... : Date of issue... : 22 September 2015 Total number of pages Applicant s name... : Bel Fuse Inc. Address... : 206 Van Vorst St., Jersey City, NJ Test specification: Standard... : IEC :2005 (Second Edition) + Am 1: Am 2:2013 Test procedure... : Non-standard test method... : CB-Scheme N/A Test Report Form No.... : Test Report Form(s) Originator... : IEC60950_1F SGS Fimko Ltd Master TRF... : Dated Copyright 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

11 Page 2 of 62 Report No Test item description... : Trade Mark... : AC/DC or DC/DC Switching Power Supply Manufacturer... : Model/Type reference... : Ratings... : Same as Applicant PFE RA, PFE3000-S361 and SPAFFIV-05G (maybe followed by SXXX indicating non-safety critical option) Model PFE RA and PFE3000-S361 Input: Output(s), DC: Vac, A, Hz or Vdc, 13-9 A V1*: 12.3 V, 244 A ; V2: 12 V, 5 A Total Maximum Power: 3060 W, 45 C ambient *Note: V1 output is derated as per the below conditions: 1400 W at Vac, 45 C ambient 1050 W at Vac, 55 C ambient 2250 W at Vac / Vdc, 55 C ambient Model SPAFFIV-05G: Input: Output(s), DC: Vac, A, Hz or Vdc, 13-9 A V1*: V, 244 A ; V2: 12 V, 5 A Total Maximum Power: 3000 W, 45 C ambient *Note: V1 output is derated as per the below condition: 2250 W at Vac / Vdc, 55 C ambient Testing procedure and testing location: CB Testing Laboratory: Testing location/ address...: Nemko USA Inc Faraday Ave. Suite 150, Carlsbad, CA 92008, USA Testing procedure:ctf-3 Testing location/ address... : Tested by (name + signature)... : BPS Pacific Electronics (Shenzhen) Co.,Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District Shenzhen PEOPLE'S REPUBLIC OF CHINA George Daverin Approved by (name + signature)... : Jeff Busch TRF No. IEC60950_1F

12 Page 3 of 62 Report No Report History: Modification1: Report has been modified due to change of Y2-capcitors C7(main board) and C16/C17 (Input board) ratings and addition of model PFE3000-S361. List of Attachments (including a total number of pages in each attachment): Attachment 1: European Group Differences and National Deviations pages Documented deviations contain individual national documents for several European countries that are already documented in the European Group Deviations. The European Group Differences: EN :2006/A11:2009/A1:2010/A12:2011/A2:2013 are considered Normative. The individual national documents (Denmark, Finland, Germany, Ireland, Norway, Spain, Sweden, Switzerland and United Kingdom) are considered Informative and included at the manufacturer s request. Attachment 2: Miscellaneous Documentation, e.g. Photos, etc pages (Not for publication Engineering use only) TRF No. IEC60950_1F

13 Page 4 of 62 Report No Summary of testing General Power supply All comments relate to all models, unless specifically stated. The equipment is an enclosed, Class I switch mode power supply with universal AC input or Class I with DC input. With multiple DC voltage outputs for building-in. This report covers multiple models and all comments / tests apply to all models unless otherwise indicated. Testing was conducted on various models as indicated ; The unit is intended to operate at an altitude of up to 4000m. This equipment is intended to be operated at an altitude of up to 4000 m, so the clearance is multiplied by the altitude correction factor (1.29), specified in table A.2 of IEC nd Edition: Refer to Tables and , 3.2.5; Power supply cord set. A power supply cord set is not provided with the power supply. A power supply cord set, complying with the national regulations of the country in which the product is to be sold, shall be provided with the end-use equipment ; Safety instructions. Instructions and equipment markings related to safety are to be provided in a language, which is acceptable in the country in which the equipment is to be sold. English language verified ; IT power distribution systems The equipment complies with the requirements for connection to the Norwegian IT power systems. The following information should be given (but is not required) in the installation instruction: This product is also designed for IT power system with Phase to Phase voltage 230V ; Number and location of protective devices. In Norway, IT power distribution system is used. Equipment with a single protective device is accepted in Norway. Other countries may have additional requirements. Equipment normal configuration is provided with a single fuse (F1) in the line phase of the input, however the power may be supplied with an optional fuse (F2) in the neutral phase of the input ; Warning to service personnel. After operation of the protective device, the equipment is still under voltage if it is connected to an IT-power system. A warning is required for service personnel. Norway does not require this warning. 5.2: Electric Strength test Increased test voltages for Basic insulation applied to the equipment, based on measured working voltages. TRF No. IEC60950_1F

14 Page 5 of 62 Report No Summary of testing: Tests performed (name of test and test clause): 1) Input Test ) Durability Test ) Energy Hazard ) Capacitance Discharge Test ) SELV Reliability Test ) Protective Bonding Test ) Humidity Test ) Working Voltage Measurement ) Hazardous Voltage Measurement ) Cemented Joint ) Impact test ) Handel Loading test ) Connector Interruption test ) Heating Test ) Touch Current Test ) Electric Strength Test ) Component Failure Test ) Abnormal Operation Test ) PS Output Overload and Short Test Testing location: BPS Pacific Electronics (Shenzhen) Co.,Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District Shenzhen PEOPLE'S REPUBLIC OF CHINA TRF No. IEC60950_1F

15 Page 6 of 62 Report No Summary of compliance with National Differences: List of countries addressed Austria (AT), Australia (AU), Canada (CA), China (CH), Denmark (DK), Finland (FI), Germany (DE), Ireland (IE), Israel (IS), Korea (KR), Norway (NO), Slovenia (SI), Spain (ES), Sweden (SE), Switzerland (CH), United Kingdom (GB), United States of America (US) The product fulfils the requirements of : EN : A11: A1: A12: A2:2013 TRF No. IEC60950_1F

16 Page 7 of 62 Report No Copy of marking plate: The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective Certification Bodies that own these marks. TRF No. IEC60950_1F

17 Page 8 of 62 Report No Calibration Measurement uncertainty Evaluation of results All instruments used in the tests given in this test report are calibrated and traceable to national or international standards. Further information about traceability will be given on request. Measurement uncertainties are calculated for all instruments and instrument set-ups given in this report. Calculations are based on the principles given in the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007, Nemko routine L227 and other relevant internal Nemko-procedures. Further information about measurement uncertainties will be given on request. If not explicitly stated otherwise in the standard, the test is passed if the measured value is equal to or below (above) the limit line, regardless of the measurement uncertainty. If the measured value is above (below) the limit line, the test is not passed - ref IEC Guide 115:2007, and Nemko routine L220. The instrumentation accuracy is within limits agreed by IECEE-CTL (ref. Nemko routine L227). TRF No. IEC60950_1F

18 Page 9 of 62 Report No Test item particulars: Equipment mobility... : [] movable [] hand-held [] transportable [] stationary [ X ] for building-in [] direct plug-in Connection to the mains... : [] pluggable equipment [] type A [] type B [] permanent connection [] detachable power supply cord [] non-detachable power supply cord [X] not directly connected to the mains [ X ] DC Mains Operating condition... : [ X ] continuous [] rated operating / resting time: Access location... : [] operator accessible [] restricted access location [X] Equipment for building in, to be evaluated in end use equipment. Over voltage category (OVC)...: [] OVC I [ X ] OVC II [] OVC III [] OVC IV [] other: Mains supply tolerance (%) or absolute mains supply values... : 90 to 300 Vac for PFE3000 Series 180 to 300 Vac for SPAFFIV-05G 192 to 400 Vdc (both models) Tested for IT power systems... : [X] Yes (Norway only) [ ] No IT testing, phase-phase voltage (V)... : 230V Class of equipment... : [X] Class I (For AC input) [ ] Class II [X] Class III (For DC input) [] Not classified Considered current rating of protective device as part of the building installation (A)... : 40 A (per manufactures specification) Pollution degree (PD)... : [] PD 1 [ X ] PD 2 [] PD 3 IP protection class... : IP20 Altitude during operation (m)... : 4000 m Altitude of test laboratory (m)... : 100 m Mass of equipment (kg)... : 2.53 kg PFE3000 Series 2.78 kg SPAFFIV-05G Possible test case verdicts: - test case does not apply to the test object... : N/A - test object does meet the requirement... : P (Pass) - test object does not meet the requirement... : F (Fail) Testing... : Date of receipt of test item... : March,2015: Septermber,2015 Date (s) of performance of tests... : March,2015: Septermber,2015 TRF No. IEC60950_1F

19 Page 10 of 62 Report No General remarks: "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Manufacturer s Declaration per sub-clause of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided... : When differences exist; they shall be identified in the General product information section. Name and address of factory (ies) : BPS Pacific Electronics (Shenzhen) Co.,Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District Shenzhen PEOPLE'S REPUBLIC OF CHINA Yes Not applicable General product information: This test report is based on Nemko test report Ref. No with appended CB cert Ref. No.NO85140, evaluated to the requirement of IEC :2005 (Second Edition) + Am 1: Am 2:2013. This test report includes the addition of a model name. PFE3000-S361 is exactly the same as PFE RA except for Multiple square holes on the side of the enclosure. Therefore only temperature data, table 4.5, was included to document this addition. Additionally the values of the Y2 capacitors and some of the bulk capacitors were changed, Table 5.1 was updated to document this change. Additionally, table was added to this report. For continuity, the entire report has been reissued, including the additional evaluation highlighted in bold text. The subject models are component type power supplies, intended for building in, provided with an overall metal enclosure, housing components operating at hazardous and SELV voltages. Multiple hexagonal holes are provided on the front and square holes on the rear of the enclosure. Supplies can operate from AC input or DC Input, with DC outputs The following PWB assemblies are provided: Main PWB is installed on multiple stand-offs secured to the chassis bottom by machine screws; Control PWB is mounted vertically along the side of the main PWB, and connected to the Main PWB through multi-pin connectors. Insulating foil is provided between PWB assemblies and enclosure panels. The units are equipped with an input connector for power connection, fan and LED. The models covered in this report do not connect directly to Mains. They are provided with connectors that interface with the host system. Class B or permanent connection to Mains must be determined in the end use equipment. Model Differences: SPAFFIV-05G is exactly the same as PFE RA except for AC input voltage rating, V1 output voltage rating, wider chassis (refer to appended table 1.5.1) and different location of bonding conductor. PFE3000-S361 is exactly the same as PFE RA except for Multiple square holes on the side of the enclosure TRF No. IEC60950_1F

20 Page 11 of 62 Report No Conditions of Acceptability: The following must be evaluated at end use: 1. The equipment has been evaluated for use in Pollution Degree 2 environment. 2. The Clearance values of the Power Supply Unit (PSU) have been evaluated for an altitude of 4000 m, under IEC :1992 Table A.2 (altitude correction factor is 1.29). 3. The ground path from the input connector to the PSU case meets protective bonding and has been evaluated at 80 A. 4. The PSU has been evaluated for use in Class I equipment. 5. The secondary outputs of the PSU are SELV. 6. V2 output is non-hazardous energy level. V1 output is at hazardous energy level. 7. The PSU has been evaluated for a TN (Including TN-S and TN-C) and TT and IT (Norway only) systems power source. 8. The PSU has been evaluated for use with a Phase Neutral power source. 9. All Isolating transformers isolation barrier insulation temperatures have been measured within the winding on the insulator. The internal temperature did not exceed the insulation Class limits for NORMAL operation and ABNORMAL operation. 10. The temperature of the Isolating Transformers, T4, T3/T9/T14/T15, T6/T7/T8/T11 isolation barrier shall be assessed in the end application. T4, T3/T9/T14/T15 employ an OBJY3 electrical insulation system designated Class F. Transformers, T6/T7/T8/T11, employs a Class B insulation system. 11. The connector current interruption test (Hot Plugging test) was conducted on the secondary connector of the PSU for 100 cycles. 12. The PSU is not intended for use in vehicles, on board ships or aircraft. 13. The front face of the PSU may be a part of the front of the end product. The front face of the PSU did pass the Impact Test. 14. Equipment is rated higher than 16A. Type of connection to Mains must be determine in the end use equipment. 15. The suitability of fusing included in the PSU construction, must be evaluated in the end use equipment. Abbreviations used in the report: - normal conditions... N.C. - single fault conditions... S.F.C - functional insulation... OP - basic insulation... BI - double insulation... DI - supplementary insulation... SI - between parts of opposite polarity... BOP - reinforced insulation... RI Indicate used abbreviations (if any):... None TRF No. IEC60950_1F

21

22

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2235802 (LR 38879) Master Contract: 173688 Project: 2235802 Date Issued: 2009/11/03 Issued to: Power-One, Inc 740 Calle Plano Camarillo, CA 93012 USA Attention: Ms.

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70076967 Master Contract: 170351 Project: 70111434 Date Issued: 2016-12-06 Issued to: Bel Fuse Inc. 206 Van Vorst St Jersey City, New Jersey 07302 USA Attention:

More information

File E Vol. 1 Sec. 125 Page 1 Issued: and Report Revised:

File E Vol. 1 Sec. 125 Page 1 Issued: and Report Revised: File E131905 Vol. 1 Sec. 125 Page 1 Issued: 2007-04-18 and Report Revised: 2009-04-24 DESCRIPTION PRODUCT COVERED: USR, CNR - Switching Power Supply, Models SPASUNM-03, SPASUNM-07, SFP1050-12B, may be

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70036125 Master Contract: 170351 Project: 70156820 Date Issued: 2017-09-21 Issued to: Bel Fuse Inc. 206 Van Vorst St Jersey City, New Jersey 07302 USA Attention:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-2 CB DE1-49619/A2/B1/M2 Date

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: T223-0035/16 Date of issue...: 2016-02-01

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY

More information

Power Supply XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA

Power Supply XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA Ref. Certif. No. US-18342-UL IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS DES EQUIPEMENTS

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

CA/11022/CSA. Lineage Power N/A. Ref. Certif. No. Component DC-DC Converters for Use With ITE

CA/11022/CSA. Lineage Power N/A. Ref. Certif. No. Component DC-DC Converters for Use With ITE IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D ACCEPTATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-26 Page 1 of 73 Report Reference # E122103-A140-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-10-20 Page 1 of 72 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements dftfdthdxfgxfx Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31182226.016 Date of issue...

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-10-20 Page 1 of 11 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-08-17 Page 1 of 21 Report Reference # E186249-A203-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2007-01-23 Page 4 of 57 Report Reference # E116994-A34-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL 60601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): COVER PAGE FOR TEST REPORT Power Supplies for Information Technology Equipment Including Electrical Business

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires TEST REPORT PN-EN 13032 Light and lighting. Measurement and presentation of photometric data of lamps and luminaires Report Number.... : BS-3/161/B/5/15 Date of issue... : 03.02.2016 Total number of pages...

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

DK M2-UL. Ref. Certif. No. CB TEST CERTIFICATE CERTIFICAT D ESSAI OC. Date: Original Issue Date:

DK M2-UL. Ref. Certif. No. CB TEST CERTIFICATE CERTIFICAT D ESSAI OC. Date: Original Issue Date: Ref. Certif. No. DK-28210-M2-UL IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D ACCEPTATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIPEMENTS

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1271882 Master Contract: 165071 Project: 2429855 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention: Mr. Michael

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : 50088663 001 Date of issue... : 2017-08-09

More information

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages... Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

Page 2 of 23 UNT150420C11

Page 2 of 23 UNT150420C11 Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):

More information

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas AS 62040.1.1 2003 IEC 62040-1-1:2002 IEC 62040-1-1:2002/Corr.1:2002 Reconfirmed 2013 AS 62040.1.1 Australian Standard Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60884-1 Plugs and socket-outlets for household and similar purposes Part 1: General requirements Report Reference No.... : Date of issue...

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 Page 1 of 15 Report No 130313TRFENV Report Reference No.... : TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 130313TRFENV Tested by... : Alessio Pelizzoni. Verified by... : Fabio Mauri. Date of issue...

More information

PLUG-IMQ 3/4

PLUG-IMQ 3/4 PLUG-IMQ 2/4 PLUG-IMQ 3/4 PLUG-IMQ 4/4 PLUG-KEMA 1/3 PLUG-KEMA 2/3 PLUG-KEMA 3/3 CERTIFICATE No. P12215783 Order No. 218230 Page 1/4 Product Applicant Manufacturer Factory Plugs Volex (Asia) Pte Ltd. 35

More information

SGS Australia Pty Ltd

SGS Australia Pty Ltd TEST REPORT AS/NZS 60598.2.2:2001 Luminaires Part 2: Particular requirements Recessed luminaires Report Reference No....: S08007 Approved by (+ signature)...: I Absolom Date of issue...: Thursday, 31 January

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....

More information

Certificate of Compliance

Certificate of Compliance FF0 002 Certificate of Compliance Issued to: Rotork Controls Inc. 675 Mile Crossing Blvd Rochester, NY 14624 USA Attention: Matt Cogill The products listed below are eligible to bear the CSA Mark shown

More information

EU RO Mutual Recognition Technical Requirements

EU RO Mutual Recognition Technical Requirements 1. PRODUCT DESCRIPTION... 1 2. DESIGN EVALUATION... 2 3. PRODUCTION REQUIREMENTS... 6 4. MARKING REQUIREMENTS... 6 5. TYPE APPROVAL CERTIFICATE CONTENT... 7 6. APPROVAL DATE AND REVISION NUMBER... 7 7.

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power

More information

ABB France 3 rue Jean Perrin CS CHASSIEU Cedex FRANCE. Eppelheimer Str HEIDELBERG - ALLEMAGNE. Contacteur Contactor

ABB France 3 rue Jean Perrin CS CHASSIEU Cedex FRANCE. Eppelheimer Str HEIDELBERG - ALLEMAGNE. Contacteur Contactor LCIE N : Titulaire : License Holder: Site de fabrication : Factory: ABB France 3 rue Jean Perrin CS 90009 69687 CHASSIEU Cedex FRANCE ABB STOTZ KONTAKT GmbH Eppelheimer Str. 82 69123 HEIDELBERG - ALLEMAGNE

More information

NovitaTech Engineering

NovitaTech Engineering NovitaTech Engineering 490869 TEST REPORT FOR PDG Product Design Group Eclipse 600 MANUAL WHEELCHAIR TEST DOCUMENTS AS3695:1992, AS3696-1:1990, AS 3696-3:1990, AS 3696-5:1989, AS 3696-8:1998, ISO 7176-7:1996

More information

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70054084 Issued to: Emerson - Rosemount, Micro Motion Inc. 12001 Technology Dr. Eden Prairie, Minnesota 55344 USA Attention: Paul Schilke The products listed below

More information

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U Instruction Manual Supplement for FRN-C2S-2U/4U (7.5 to 20 HP) Compact Inverter 200 V series: FRN0025 to 0060C2S-2U series: FRN0013 to 0030C2S-4U Thank you for purchasing our FRENIC-Mini series of inverters.

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION CLC/TS 50457-1 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION March 2008 ICS 43.120 Supersedes ENV 50275-2-3:1998 English version Conductive charging for electric vehicles - Part

More information

Date received into service; / /.

Date received into service; / /. Innovating Together RIGEL SafeTest 50 electrical safety analyzer Copyright 2016 SEAWARD GROUP Last Update: April 20th 2016 Instruction Manual 410A570 Revision 1.2 Limited Warranty & Limitation of Liability

More information

Small craft Electric propulsion system

Small craft Electric propulsion system INTERNATIONAL STANDARD ISO 16315 First edition 2016-03-15 Small craft Electric propulsion system Petits navires Système de propulsion électrique Reference number ISO 16315:2016(E) ISO 2016 ISO 16315:2016(E)

More information

Update on Fast SAR Techniques and IEC V3. Matthias MEIER Chairman of Advisory Board, ART-Fi 10 April 2014

Update on Fast SAR Techniques and IEC V3. Matthias MEIER Chairman of Advisory Board, ART-Fi 10 April 2014 Update on Fast SAR Techniques and IEC 62209 V3 Matthias MEIER Chairman of Advisory Board, ART-Fi 10 April 2014 ART-Fi Company Profile Mission: developing radiofrequency solutions for efficient design and

More information

Single & Three-Phase Soft Starters

Single & Three-Phase Soft Starters Submittal Data English Language/IP Units 11/13 Contact Information: Hyper Engineering, Pty. Ltd. 9000 Conservation Way Fort Wayne, IN 46809 www.hypereng.com sales@hypereng.com (877) 304-0724 Model Nomenclature

More information

TEST REPORT. IEC 62133: 2012 (Second Edition)

TEST REPORT. IEC 62133: 2012 (Second Edition) Test Report issued under the responsibility of: TEST REORT, Second Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary

More information

Power and Cooling. Chassis Power System

Power and Cooling. Chassis Power System This chapter describes the Cisco NCS 6000 Series Routers power and cooling systems. It also provides the power, grounding, and cooling requirements for the installation site to help you plan the site facilities

More information

Certificate of Compliance

Certificate of Compliance FF0001 Certificate of Compliance Certificate: 1345550 Issued to: Eaton Electric Ltd. Great Marlings Butterfield, Luton Bedfordshire LU2 8DL United Kingdom Attention: Mr. Peter Rigling The products listed

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 10924-2 First edition 2014-02-15 Road vehicles Circuit breakers Part 2: User s guide Véhicules routiers Coupe-circuits Partie 2: Guide de l utilisateur Reference number ISO 10924-2:2014(E)

More information

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

Regulatory Compliance Engineering News

Regulatory Compliance Engineering News UPCOMING REGULATORY REQUIREMENTS 1. IEC / EN60950-1 will soon be replaced by IEC / EN62368-1 2015 2016 2017 2018 2019 June 20 IEC / EN60950-1 (Safety Standard for ITE) is to be withdrawn by June 20, 2019.

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 16183 First edition 2002-12-15 Heavy-duty engines Measurement of gaseous emissions from raw exhaust gas and of particulate emissions using partial flow dilution systems under

More information

Provläsningsexemplar / Preview. Fourth edition

Provläsningsexemplar / Preview. Fourth edition Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 1813 Fourth edition 2014-02-15 Belt drives V-ribbed belts, joined V-belts and V-belts including wide section belts and hexagonal belts Electrical

More information

Test Report issued under the responsibility of: Report Number...:

Test Report issued under the responsibility of: Report Number...: Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND Reference No.: WTF16F0961094C age 2 of 5 Test Results: Test Item(s) Unit Test Result No.1 MDL Maximum Allowable Limit Lead (b) % ND 0.0002 See comment if > 0.004 % Cadmium (Cd) % ND 0.0002 0.002 Mercury

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

DALI 650mA LED Driver

DALI 650mA LED Driver Installation Guide DGLC650C18DD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION ISO/TS 19425 First edition 2015-12-15 Reciprocating internal combustion engines Measurement method for air cleaners Sound power level of combustion air inlet noise and insertion

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

Intertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc.

Intertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc. Test Report issued under the responsibility of: TEST REORT IEC 62133, First Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2049843 (LR 12730-263) Master Contract: 165071 Project: 2460955 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention:

More information

DEUTSCHE NORM June Plastics Symbols and abbreviated terms Part 1: Basic polymers and their special characteristics (ISO : 2001)

DEUTSCHE NORM June Plastics Symbols and abbreviated terms Part 1: Basic polymers and their special characteristics (ISO : 2001) DEUTSCHE NORM June 2002 Plastics Symbols and abbreviated terms Part 1: Basic polymers and their special characteristics (ISO 1043-1 : 2001) English version of DIN EN ISO 1043-1 { EN ISO 1043-1 ICS 01.040.83;

More information

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications. LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications. In case of mains or unit failure the DC UPS function enables

More information

Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT

Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT Date of publication: 1 November 2016Not yet published Issued by: Mark Wogan, Manager Energy Safety WorkSafe New ZealandNot yet issued Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 10924-1 Second edition 2016-04-01 Road vehicles Circuit breakers Part 1: Definitions and general test requirements Véhicules routiers Coupe-circuits Partie 1: Définitions et

More information

17AM Thermal Protector for Motor / Ballast for Fluorescent and Temperature Sensing Controls

17AM Thermal Protector for Motor / Ballast for Fluorescent and Temperature Sensing Controls 17AM Thermal Protector for Motor / Ballast for Fluorescent and Temperature Sensing Controls Introduction The Sensata Technologies 17AM delivers the maximum protection in the smallest package at an excellent

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of Fujitsu Technology Solutions GmbH Product Compliance Center Restricted TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-28107-6 EN 1008:2002 SOUTH AFRICAN NATIONAL STANDARD Mixing water for concrete Specification for sampling, testing and assessing the suitability of water, including water recovered from

More information

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12 miconverter 18-Module Rack-Mount Power Chassis User Manual Page 12 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 General and Copyright Notice This publication is protected by

More information