AG 400 relay - Gold plated, 4 contacts

Size: px
Start display at page:

Download "AG 400 relay - Gold plated, 4 contacts"

Transcription

1 - Gold plated, 4 contacts Datasheet Features Instantaneous relay Plug-in design with secure locking feature for maximum ease of maintenance 4 double make / double break C/O contacts (form Z), gold plated on silver Contact life (mechanical) of 00 million cycles -40 C C operating temperature Contacts cross pollution barrier Optional weld no transfer function Benefits Description The AG 400 relay has 4 double make / double break C/O contacts (form Z). The contacts are gold plated on hard silver. This relay is used when dry circuits route to socket are not identified. The plug-in design offers secure locking feature for maximum ease of maintenance (no wires need to be disconnected or other hardware removed for relay inspection or replacement). The resistance to impact and vibration is conform to standards in force for Railway Transported Equipment. Positive mechanical keying of relay to socket is built into relay and socket during manufacture and terminal identifications are clearly marked on identification plate that is permanently attached to the relay. Proven reliable Long life cycle Easy to maintain and replace Low life cycle cost No maintenance Railway compliancy NF F Rolling stock - Instantaneous relays contacts and sockets NF F6-0/02 Fire behaviour - Railway rolling stock The AG 400 relays is pluggable in the following sockets: EA 02 A, EA 02 AF, EA 03 AF, EA 04 A, EA 04 AF, EA 0 AF, EA 2 AF. Application The AG 400 relay is designed for low level signals switching in dry circuit signal information. The relay is equipped with a contact pollution barrier in case of mixed load operation.

2 Functional and connection diagrams Timing diagram Relay pin correspondence Example: BG keying Relay pin correspondence a b c d R P O C B D A S T N E F K J H W V L M G (rear view of relay shown) X U Y Z a b c d N.B.: Transil not needed on VAC coil relays Led (V) option (respect polarity) D D2 D3 D4 Connection diagram B A C B A C B A C B2 A2 C2 B2 A2 C2 B2 A2 C2 B3 A3 C3 B3 A3 C3 B3 A3 C3 B4 D A4 C4 B4 D A4 C4 B4 D A4 C4 D2 D2 D2 D3 D3 D3 D4 D4 D4 VDC Models (no Transil protection) VDC Models (with Transil protection) VAC Models N.B.: Transil not needed on VAC coil relays. 2

3 Coil data - DC versions Keying Unom (VDC) Uoperating (VDC) () Coil resistance tol.: ± 8% at 20 C (2) Valid for closed relay. Pnom (W) Uhold (VDC) Udrop-out (VDC) R coil (Ω) () L/R (ms) (2) AG 24 6 / FL 36 2 / DG / BG / SV 0 7 / EG 2 88/ Coil data - AC versions Keying Unom (VAC) Uoperating (VAC) Pnom (VA) Uhold (VAC) Udrop-out (VAC) R coil (Ω) () L/R (ms) (2) SZ 80/ CG / () Coil resistance tol.: ± 8% at 20 C (2) Valid for closed relay. Contact data - dry circuit application (gold contacts) Contact configuration 4 C/O double break contact Contact design Stationary contacts 2 single contacts (contacts are in series) Movable contacts solid blade Contact resistance < 20 mω at A (carry only) Maximum contact ratings Operating 20 ma maximum at 72 VDC Carry only (no make and break) A maximum at VDC Minimum current ratings 0 ma at 2 VDC Contact material Stationary contacts Gold plated over hard silver Movable contacts Gold over hard silver overlay laminated to copper 3

4 Contact design Change Over double break contacts Change Over double break contacts with Weld No Transfer option Electrical characteristics Dielectric strength Insulation resistance 2000 VAC, min between contacts 2600 VAC, min between contacts, coil and frame > 000 MΩ at 00 VDC Mechanical & environmental characteristics Vibration NF F The tests are conducted in the X, Y, Z planes at frequency between 0 & 0 cycles (sinusoidal) at 2 g Shock NF F Tests are applied in both directions in the X, Y & Z planes. Then successive shocks are administered consisting of the positive component of sinusoidal with a value of 30 g, 8 ms Other vibration and shock tests can be performed on request Mechanical life > 00 x 0 6 operations Weight 300 g Temperature -40 C C Humidity 93% RH, 40 C for 4 days Salt mist % NaCl, 3 C for 4 days Protection IP40 (relay on socket) Fire & smoke Materials: Polycarbonate (cover) / polyester melamine (base) Note: These materials have been tested for fire propagation and smoke emission according standards NF F 6-0, NF F

5 Dimensions (mm) Used with locking brackets Used with wire locking spring

6 Dynamic relay selection curve No AC Current breaking capacity versus life expectancy in millions of cycles. Rate of contacts opening and closing = 200 operations per hour. Curves shown for resistive load (Power Factor = ). Curve VAC Millions of Cycles 2, 2 0, 0,2 0, 0, 2 2, Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 6

7 Dynamic relay selection curve No 2 DC Current breaking capacity versus life expectancy in millions of cycles. Rate of contacts opening and closing = 200 operations per hour. Curves shown for inductive load: L/R= 20 ms continuous current L/R= 40 ms continuous current * By connecting 2 contacts in series, DC current breaking capacity increases by 0 % Curves VDC Millions of Cycles , 0 0,2 0,2 0, Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 7

8 Dynamic relay selection curve No 3 DC Current breaking capacity versus life expectancy in millions of cycles. Rate of contacts opening and closing = 200 operations per hour. Curves shown for resistive load (L/R = 0). Continuous current. * By connecting 2 contacts in series, DC current breaking capacity increases by 0 % Curve VDC Millions of Cycles , 0 0,2 0,2 0, Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 8

9 Dynamic relay selection curve No 4 Maximum contact breaking capacity versus voltage for a given L/R. Rate of contacts opening and closing = 600 operations per hour. Curves shown for resistive load (L/R=0) and inductive loads. Continuous current. Life expectancy: 2 Millions of Cycles Curve L/R= 0ms ms 20ms 40ms 60ms 00ms Volts Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 9

10 Dynamic relay selection curve No Maximum power interruption versus load time constant (L/R) for a given voltage. Curves shown for resistive loads. I = P/V. Curve VDC L R ms A 0 2 2A A Watts (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration) 0

11 Dynamic relay selection curve No 6 AC Current breaking capacity versus life expectancy in millions of cycles. Rate of contacts opening and closing = 200 operations per hour. Values shown for inductive loads - Cos Ø = 0.7 Cos Ø = 0. Curves,3 &4 2, &7 6,9 &0 8, &2 Cos Ø = 0.3 VAC Millions of Cycles 2, , 0,2 0, 0, 2 2, Amps (for specific power contacts on customer circuitry only, not interchangeable into another socket with different customer circuitry configuration)

12 Mounting possiblities / sockets EA 02 A EA 03 AF EA 04 A EA 2 AF Panel/flush mounting EA 02 A EA 02 AF EA 04 A EA 04 AF EA 2 AF Locking bracket (90843), rear connection, double Faston mm Wire locking spring (92683), rear connection, single Faston mm Locking bracket (90843), rear connection, single Faston x 0.8 mm Wire locking spring (92683), rear connection, single Faston x 0.8mm Wire locking spring (92683), rear connection, crimp contact Surface/wall mounting EA 03 AF* EA 0 AF* Wire locking spring (92683), front connection, M3 screw 6. mm ring terminals (2, mm 2 ) Wire locking spring (92683), front connection, single Faston mm * Mounting possibility on 3 mm rail EN 0022 by adding suffix D to the part number (see socket datasheet) Note: Keying of relay to socket can be specified by adding the keying letters in the part number. See all details in the related socket datasheet. 2

13 Spare parts Spare parts - order part numbers () () () () LOCKING BRACKET () () SCREW FOR BRACKET METAL STRAP (2) METAL STRAP (4) C92720 P (2) (3) P92806 WIRE LOCKING SPRING ROUND PLASTIC PLUGS HEX. PLASTIC KEYS LOCK PINS ASSY 2 SCREWS () Parts only for socket (2) Parts for relay and socket (3) Parts only for relay 3

14 Instructions Installation Install socket and connect wiring correctly according identification to terminals. Plug relay into socket. Reverse installation into socket not possible due to mechanical blocking by snap-lock. Don t reverse polarity of coil connection. Relays can be mounted (tightly) next to each other and in any attitude. Warning! Never use silicon spray near by relays Operation Before operating always apply voltage to coil to check correct operation. Long term storage may corrode the silver on the relay pins. Just by plugging the relay into the socket, the female bifurcated receivers will automatically clean the corrosion on the pins and guarantee a good connection. Do not use the relay in places with flammable gas as the arc generated from switching could ignite gasses. Maintenance Correct operation of relay can easily be checked as transparent cover gives good visibility on the moving contacts. When the relay doesn t seem to operate correct, please check presence of coil voltage. Use a multimeter. If LED is used, coil presence should be indicated. If coil voltage is present, but the relay doesn t work, a short circuit of suppression diode is possible (The coil connection was reversed). If relay doesn t work after inspection, please replace relay unit by a similar model. Send defective relay back to manufacturer. Normal wear and tear excluded. 4

15 Ordering scheme Configuration: AG AG S C V F. Relay model 2. Nominal 3. Keying 4. Coil. Weld 6. LED 7. Cover 8. Language voltage OVP no transfer ind. type (test report) This example represents a AG AG S C V F. Description: AG 400 series relay, Unom: 24 VDC, Keying AG, Transil coil protection, Weld no transfer, LED indicator, relay cover for wire locking spring, test report in English. Relay model AG & 3. Nominal voltage and keying AG FKL DG BG US SV EG 24 VDC 36 VDC 48 VDC 72 VDC 96 VDC 0 VDC 2 VDC SZ CG VAC 220 VAC 4. Coil overvoltage protection No coil protection P Avalance diode coil protection S Transil coil protection (only with 400 type). Weld no transfer option Regular double break contacts C Weld no transfer 6. LED indicator No LED V LED voltage indicator 7. Relay cover type Relay cover with lock pins F Relay cover forwire locking spring 8. Language on test report French English 2 Spanish

16 MS Relais SAS AG 400 relay-v.2 Nov 20 Tour Rosny 2, Avenue du Général de Gaulle, F Rosny-sous-Bois Cedex, FRANCE T +33 (0) , F +33 (0) E sales@msrelais.com Mors Smitt Asia Ltd. # 807, Billion Trade Centre, 3 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T , F E info@morssmitt.hk Nieaf-Smitt B.V. Vrieslantlaan 6, 326 AA Utrecht, NETHERLANDS T +3 (0) , F +3 (0) E sales@nieaf-smitt.nl Mors Smitt Technologies Inc. 420 Sackett Point Road North Haven, CT 06473, USA T + (203) , F + (888) E mstechnologies@msrelais.com Mors Smitt UK Ltd. Doulton Road, Cradley Heath West Midlands, B64 QB, UK T +44 (0) , F +44 (0) E info@morssmitt.co.uk (c) Copyright 20 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.

N.S1-P relay - Signalling, post

N.S1-P relay - Signalling, post - Signalling, post Datasheet Features Instantaneous electro-mechanical vital relay Weld resistant contacts Weld no transfer contacts Gravity drop out Solid gold and bifurcated contacts -25 C...+70 C operating

More information

Description The EA 112 socket has crimp contacts to allow rear connection on the socket.

Description The EA 112 socket has crimp contacts to allow rear connection on the socket. E 112 - Socket Datasheet Features Rear connection, with crimp contacts No internal soldering / connections For panel/flush mount Wire locking spring E 112 suitable for all relays and modules ( 400, K,

More information

FR circuit breaker - hydraulic magnetic,

FR circuit breaker - hydraulic magnetic, FR circuit breaker - hydraulic magnetic, Datasheet railway, very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

PDR circuit breaker - Ground fault Datasheet

PDR circuit breaker - Ground fault Datasheet - Ground fault Datasheet protection device Features Blue housing 1-3 poles plus neutral 7-100mA Preciese, temperature independent operation Choise of time delays, terminals and actuator colours Application

More information

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet FR circuit breaker - hydraulic magnetic, railway, Datasheet very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

RBR circuit breaker - Remote operated

RBR circuit breaker - Remote operated - Remote operated Datasheet Features ON-OFF and trip indication Load shedding Energy management Compact size Automatic reset capable Choice of interface styles Panel or 35 mm rail mounting Manual operation

More information

AR circuit breaker - Hydraulic magnetic,

AR circuit breaker - Hydraulic magnetic, AR circuit breaker - Hydraulic magnetic, Datasheet railway, small Features Description Small hydraulic magnetic circuit breaker for railway applications to protect electronic equipment and components against

More information

ER circuit breaker - Hydraulic magnetic,

ER circuit breaker - Hydraulic magnetic, ER circuit breaker - Hydraulic magnetic, Datasheet railway, high current and voltage Features Ideal for high current and high voltage applications Precise, temperature independent operation Panel mount

More information

Energy and traction control solutions

Energy and traction control solutions Mors Smitt Railway Technology Energy and traction control solutions Accurate technology for all high voltage and high current measurement applications Mors Smitt Railway Technology Energy and traction

More information

CR circuit breaker - hydraulic magnetic,

CR circuit breaker - hydraulic magnetic, CR circuit breaker - hydraulic magnetic, Datasheet railway, compact Features Precise, temperature independent operation Panel mount Integrated auxiliary contacts (optional) Up to 6 poles configuration

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch Edition 10/2016 HMI Components Series Characteristics The compact Series is especially suited for: Flush design The large rectangular design (24x36mm) features a large illuminated area. Functions The Series

More information

General Purpose Relay

General Purpose Relay General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil 2, 3 or 4 C/O contacts Switching performance up to 3000 VA Relay height 29 mm Cadmium-free contact material Mechanical indicator Manual test tab, optionally lockable. White marking tabs Applications Universal

More information

Miniature Intermediate Power Relay HY

Miniature Intermediate Power Relay HY Miniature Intermediate Power Relay HY A switching capabilities (C, C).kV dielectric strength (between coil and contacts) Various terminals, test button available Different sockets available to pole configurations

More information

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight VDE 2c, 3c AMP POWER RELAY RELAYS 2. 1.72 FEATURES Interchangeable with existing models Long life and high reliability High contact capacity up to A 20 Available with plug-in/solder and quick-connect terminals

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Arc barrier equipped High dielectric strength (2,000 VAC) Long dependable service life assured by AgCdO contacts Choose models with single or bifurcated contacts, LED indicator, diode

More information

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series Industrial Automation Catalog Section - U906 Relays Selection Guides General Purpose Relays RU Series RR Series For up-to-date information, or to request a full copy of this catalog, contact us at www.idec.com

More information

Model Number Structure

Model Number Structure Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can

More information

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control Connect - Contact - Control 3 Contactors CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en More information at: schaltbau-gmbh.com 42 CH1130/02 Single pole high-voltage contactor

More information

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0 General Purpose Relay LY Arc barrier equipped. High dielectric strength (2,000 VAC). Long dependable service life assured by Ag-Alloy contacts. Choose models with single or bifurcated contacts, LED indicator,

More information

MMC RTX series EN3716

MMC RTX series EN3716 MMC RTX series EN3716 7 CONTENTS Page Introduction... 7-4 Application 7-4 Features... 7-4 Product overview... 7-5 Electrical characteristics... 7-6 Mechanical & environmental characteristics... 7-6 Products

More information

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3

More information

High Performance Thermal-Magnetic Circuit Breakers 410/520/

High Performance Thermal-Magnetic Circuit Breakers 410/520/ High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism

More information

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes EPIC Hermetic Sealed DC and AC Contactor - 150+ Power Switching RoHS Compliant, all date codes File E320908 All contact ratings and coil versions may not be UL recognized. Contact GIGAVAC for a copy of

More information

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc. Technical Data, High Power 2-way* Electrical Data Operating Voltage Operating Current Contact Resistance Voltage Proof Insulation Resistance Mechanical Data 48 VDC* see derating curve 2 mω max. 1000 VAC,

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

Functions The Series 19 incorporates the following functions: Indicator Pushbutton Illuminated pushbutton

Functions The Series 19 incorporates the following functions: Indicator Pushbutton Illuminated pushbutton Edition 11/2013 HMI-Components 19 Series Characteristics The compact 8 mm Series 19 is especially suited for: Raised design PCB (with adaptor) The low level switching element is laid out for low current

More information

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

General_technical_data Series

General_technical_data Series Emergency-stop Switching system The double-break switching system can be supplied for the following switching functions: 1 Normally closed, 2 Normally closed, 1 Normally closed + 1 Normally open. The Normally

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Industrial Relay KML(1C, 2C)

Industrial Relay KML(1C, 2C) Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US Hermetically Sealed Relay MY4H Hermetically Sealed Relay Ideal for Hazardous Locations Class 1 Division 2 approved. Fully hermetically sealed for hazardous locations. Cadmium-free contacts for environment-friendly

More information

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Contact form Terminal Single-side stable Single-winding latching PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98 mw pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Plastic-sealed construction. Unique moving

More information

Simulator switch, magnetic operation

Simulator switch, magnetic operation Description Single pole, miniaturised aircraft simulator switch with extremely fast magnetic trip time. Blade, screw and wire wrap terminals. Aircraft style threadneck and push/pull button with white trip

More information

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection PRODUCT NEWS Product Discontinuation Notices February 1, 2012 Safety Relays No. 2012037E Discontinuation Notice of Safety Relay and Socket., P7S series Product Discontinuation Safety Relay Socket P7S series

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Designed small, 2- and 3-pole types break 5 A loads and 4-pole type, 3 A load High reliability, long life Ultra-high sensitivity with quick response High vibration/shock resistance

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Date received into service; / /.

Date received into service; / /. Innovating Together RIGEL SafeTest 50 electrical safety analyzer Copyright 2016 SEAWARD GROUP Last Update: April 20th 2016 Instruction Manual 410A570 Revision 1.2 Limited Warranty & Limitation of Liability

More information

55 Series - Miniature General Purpose Relays 5-10 A

55 Series - Miniature General Purpose Relays 5-10 A Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

Features. Description. Table of Contents

Features. Description. Table of Contents Features Very low profile Very high efficiency (typically 90%) Single and dual output versions Input voltages from 24V to 110VDC nominal voltages from 5V to 48VDC -40 C to +71 C operation without de-rating

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics

More information

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket Technical Datasheet 1SNK1659D01 Catalogue Page 1SNK160S01 ZK2.5-SP-P PI-Spring Terminal Blocks Disconnect with plug - with test socket The flexible solution for fitting the component of your choice in

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection,

More information

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12). Low Signal Relay High sensitivity can be driven by digital circuits Low-profile design allows use in 12.70 mm (0.50 in) PC board rack Surge withstand voltage meets FCC Part 68 regulation Units can be mounted

More information

Signal Signal Relays. Potter & Brumfield. R10 Series Relay

Signal Signal Relays. Potter & Brumfield. R10 Series Relay R Series Relay n 1 through 8 form C (CO) contact arrangement n Broad range of coil options provides sensitivity ranging from 25 to 750mW n Various contacts switch from dry circuit to 7.5 amps n Many mounting

More information

Latching SPST EPIC Sealed Contactor Amp Power Switching RoHS Compliant, all date codes

Latching SPST EPIC Sealed Contactor Amp Power Switching RoHS Compliant, all date codes Latching SPST EPIC Sealed Contactor - 350+ Power Switching RoHS Compliant, all date codes Patent Pending Latching version of GIGAVAC GX14. Chassis level UL508 sized power terminals No need for specially

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Nominal operating voltage Maximum operating voltage C High temp test

Nominal operating voltage Maximum operating voltage C High temp test ENGINEERING DATA SHEET SERIES 9 CONTACTOR AMP Balanced armature design Hermetically sealed, mechanical interlock Designed to the performance standards of MILPRF6106 PRINCIPLE TECHNICAL CHARACTERISTICS

More information

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Ideal

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

MICRO SWITCH INSTALLATION SHEET

MICRO SWITCH INSTALLATION SHEET MICRO SWITCH INSTALLATION SHEET Micro Switch Cam Rest Position See Vertical or Horizontal Arm Installation Instructions for Micro Switch activation sequence. Micro Switch Cam Adjustment Screw SW 1 Micro

More information

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR:

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR: SERIES 782XBX/XDX DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FEATURES FLAG INDICATOR: L.E.D. STATUS LAMP: PUSH BUTTON: LOCK-DOWN DOOR: FINGER-GRIP COVER: I.D. TAG/WRITE LABEL: COVER ADAPTERS: BENEFITS

More information

02/11/2015

02/11/2015 V4 8318 Sealed Dual-current 83181 Part number made to order IP 67 protection Nominal ratings 0.1 A to 10 A / 250 VAC Minimum rating 1 ma / 4 VDC Operating temperature -40 C to +125 C Choice of actuators

More information

General purpose relays 6-10 A

General purpose relays 6-10 A 60 SЕRIES General purpose relays 6-10 Shipyards Hoists and cranes Road / tunnel lighting Burners, boilers and furnaces Wood-processing machines Panels for electrical distribution Control panels Control

More information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay Creepage distance of 8.0 mm (0.31 in) min. between coil and contact Dual-winding latching type available Plug-in and quick-connect terminals available High sensitivity (360 mw) and high

More information

Features. * 2 Form C contact. * High switching capacity 60W, 125VA. * Fit standard 16 pin IC socket. * Epoxy sealed for automaitc-wave COIL

Features. * 2 Form C contact. * High switching capacity 60W, 125VA. * Fit standard 16 pin IC socket. * Epoxy sealed for automaitc-wave COIL JRC-27F SUBMINIATURE DIP RELAY Features File No.:E133481 * 2 Form C contact * High switching capacity 60W, 125VA * Fit standard 16 pin IC socket * Epoxy sealed for automaitc-wave soldering and cleaning

More information

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit Technical Datasheet SNK607D00 Catalogue Page SNK607S00 ZS4-D-S-T Screw Clamp Terminal Blocks Double deck with disconnect circuit with test socket screws and feed-through circuit Find the same functionalities

More information

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T 46 and 56 Series - Relays for railway applications 8-12 A Features 46.52T 56.32T 56.34T Plug-in power relays: 8 A, 2 pole 12 A, 2 and 4 pole DC coils with extended range Complies with UNI CEI 11170-3 (protection

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK646D00 Catalogue Page ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Model Number Structure

Model Number Structure Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action

More information

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement. DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally

More information

KD1E Range Potential Indicators

KD1E Range Potential Indicators KD1E Range Potential Indicators Operating Instructions 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Limited Warranty & Limitation

More information

Renewable Energy. Circuit Breakers and Disconnects

Renewable Energy. Circuit Breakers and Disconnects Renewable Energy Circuit Breakers and Disconnects HARNESS THE POWER About Carling Technologies Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm Power Relays RL Series PRODUCT DESCRIPTION Quick Connect Flange Mount SPECIFICATIONS Number of poles pole 2 poles Contact Configuration X (SPST, double make) 2X (DPST, double make) Contact material Ag

More information

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK6D00 Catalogue Page SNK6S00 ZS4-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

G-Series DIN-RAIL CIRCUIT BREAKER

G-Series DIN-RAIL CIRCUIT BREAKER G-Series DIN-RAIL CIRCUIT BREAKER The G-Series hydraulic-magnetic circuit breaker insures maximum protection by integrating wiping contacts for longevity; a common trip linkage between poles; a unique

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

REP Series. Environmentally-Sealed Rectangular Plastic Connectors

REP Series. Environmentally-Sealed Rectangular Plastic Connectors Environmentally-Sealed Rectangular Plastic Connectors REP Series Environmentally - Sealed Rectangular Plastic Connectors Optimised for use in rail and embedded applications Smiths Interconnectors REP Series,

More information

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets Technical Datasheet SNK603D00 Catalogue Page SNK6038S00 ZK.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets The flexible solution for fitting the component of your choice in series

More information

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator Technical Datasheet SNK63D00 Catalogue Page SNK63S00 ZS-SF-R Screw Clamp Terminal Blocks For x 0 and x fuses - with blown fuse indicator - Protect your circuit with x and x0 fuse terminal blocks (fuse

More information

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS 1 P/N: PS-P INSTALLATION & SETTING INSTRUCTIONS YELLOW INDICATION FLAG: P/N STP-F The Indication Flag should be fitted when there is more than one switch used on the conveyor as noted in AS1755-2000 Clause

More information

Type Terminal Coil Contact form Model

Type Terminal Coil Contact form Model General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode

More information

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator Technical Datasheet SNK605D00 Catalogue Page SNK60S00 ZK.5-SF-R PI-Spring Terminal Blocks For 5x0 fuses - with blown fuse indicator - Protect your circuits with 5x0 fuse terminal blocks compliant with

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent

More information

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit Technical Datasheet SNK649D00 Catalogue Page ZS6-D-PE Screw Clamp Terminal Blocks Double deck with ground circuit - Save space with double deck ground terminal blocks aligned with ZS6-D double deck terminal

More information

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi 46 Series - Miniature industrial relays 8-16 A Features 46.52 46.61 1 & 2 Pole relay range 46.52-2 Pole 8 A 46.61-1 Pole 16 A Socket mount or direct connection via Faston connectors AC coils & DC coils

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

CX-Series. Circuit Breaker

CX-Series. Circuit Breaker CX-Series Circuit Breaker The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information