Industrial Switchgear
|
|
- Christian Bryant
- 5 years ago
- Views:
Transcription
1 Industrial Switchgear w.e.f. 1 st August 2018
2 2 CORPORATE OFFICE
3 About STANDARD STANDARD is a part of $1.4 Billion leading Fast Moving Electrical Goods (FMEG) Company, Havells India Ltd. The company offers a wide range of highly differentiated domestic & industrial products such as MCBs, RCCBs, Distribution Boards (DBs), MCCBs, RCBOs Changeover Switches, Switch Disconnector Fuses (SDFs), HBC Fuses, Modular Switches, Copper Flexible Cables etc. Last year, the Company ventured into consumer product category with its foray into domestic fans segment. Today, Standard boasts of having a comprehensive range of ceiling fans, table-fans, wall-mounted fans, pedestal fans and domestic exhaust fans. STANDARD has been serving the Indian customers with superior quality products for over five decades and has built a formidable reputation with its high quality products in domestic as well as international market. STANDARD has pan-india marketing and distribution network stretching over 42 branch offices, 1,200 authorized dealers and 10,000 strong retail outlets across the country. The company also has a wide presence in International markets as well. Some on the countries where STANDARD is present are Middle East, South East Asian countries, Malaysia, Singapore, South Africa, Kenya, Ghana, Nigeria. It has established a well-equipped infrastructure with state of the art facilities in terms of plant, machinery and testing. STANDARD products are manufactured at most modern and technologically integrated plants of its parent, Havells India, located in different parts of country such as Haridwar, Baddi, Sahibabad, Faridabad and Alwar. All STANDARD products are designed on the lines of Indian & International specifications and tested by nationally accredited laboratories CPRI/ERDA. R&D is ebbed in company s DNA. The company has a very strong R&D team that has driven innovation to continuously deliver world-class products. Its R&D centers are equipped with supreme quality CAD/CAM machines for its entire stage of design and development. The R&D team continuously works to create innovative solutions and new products of high reliability and safety catering to meet the ever-changing demands of various segments of customers. All its products are incorporated with special technology rated for 10% higher current carrying capacity and can withstand high temperature rise even during the worst of overloading and offer best in class safety features along with better performance during low voltage conditions too. Standard s entire product range offers high performance, best design and superior features like energy savings, longer life and shock proof to name a few. With its mission to offer quality products, efficient customer service and everlasting relationship with value chain partners, STANDARD holds certain unbeatable advantages like expertise in LT Switchgear since last four decades, technology leadership, excellent brand perception, wide dealer network, excellent after sales service and value for money to its customers. 3
4 4 INDUSTRIAL PRODUCT
5 CONTENTS Air Circuit Breaker (ACB)...06 Bus Bar Chambers...14 Moulded Case Circuit Breakers (MCCB)...14 MCCB Enclosures...16 Digital Moulded Case Circuit Breakers (MCCB)...17 SHIP Series MCCB (Adjustable thermal & fixed magnetic setting)...18 SHIP Series MCCB (Adjustable thermal & fixed magnetic setting)...18 EASYBREAK 1 MCCB (Adjustable thermal & fixed magnetic setting)...19 mccb Panel Boards (Load Star)...20 Switch Disconnector Fuse (Cubicle)...24 Dmc Fuse Bases...25 Hbc Fuse Links...25 Stanguard Switch Disconnector...26 Stanguard (Onload Changover)...26 Stanguard FP By Pass Switch...27 Automatic Transfer Switch (ATS)...27 Off-Load Changeover Switches...29 Double Break Fuse Switch s...29 Rewirable Swich Fuse s...30 Kit Kat Rewireable
6 Industrial Switchgear w.e.f. 1st August 2018 Air Circuit Breaker (Conforms to IEC: / IS: ) ACB with Microprocessor Release IPR E+ (3 Pole) inbuilt O/L & S/C protection Current Ordering Code Ordering Code Rating Capacity MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISATE1E060**# ISATE2E060**# ISATE4E06$**# ISATE5E06$**# ISATE1E080**# ISATE2E080**# ISATE4E08$**# ISATE5E08$**# ISATE1E100**# ISATE2E100**# ISATE4E10$**# ISATE5E10$**# ISATE1E120**# ISATE2E120**# ISATE4E12$**# ISATE5E12$**# ISATE1E160**# ISATE2E160**# ISATE4E16$**# ISATE5E16$**# ISATE1E200**# ISATE2E200**# ISATE4E20$**# ISATE5E20$**# ISATH1E250**# ISATH2E250**# ISATH4E25$**# ISATH5E25$**# ISATV1E320**# ISATV2E320**# ISATV4E32$**# ISATV5E32$**# ISATV1E400**# ISATV2E400**# ISATV4E40$**# ISATV5E40$**# ACB with Microprocessor Release IPR E+ (4 Pole) inbuilt O/L & S/C protection Current Rating Capacity Ordering Code Ordering Code MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISAFE1E060**# ISAFE2E060**# ISAFE4E06$**# ISAFE5E06$**# ISAFE1E080**# ISAFE2E080**# ISAFE4E08$**# ISAFE5E08$**# ISAFE1E100**# ISAFE2E100**# ISAFE4E10$**# ISAFE5E10$**# ISAFE1E120**# ISAFE2E120**# ISAFE4E12$**# ISAFE5E12$**# ISAFE1E160**# ISAFE2E160**# ISAFE4E16$**# ISAFE5E16$**# ISAFE1E200**# ISAFE2E200**# ISAFE4E20$**# ISAFE5E20$**# ISAFH1E250**# ISAFH2E250**# ISAFH4E25$**# ISAFH5E25$**# *** 100 ISAFV1E320**# ISAFV2E320**# ISAFV4E32$**# ISAFV5E32$**# *** 100 ISAFV1E400**# ISAFV2E400**# ISAFV4E40$**# ISAFV5E40$**# ACB with Microprocessor Release IPR 1 (3 Pole) inbuilt O/L, S/C & E/F protection Current Ordering Code Ordering Code Rating Capacity MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISATE11060**# ISATE21060**# ISATE4106$**# ISATE5106$**# ISATE11080**# ISATE21080**# ISATE4108$**# ISATE5108$**# ISATE11100**# ISATE21100**# ISATE4110$**# ISATE5110$**# ISATE11120**# ISATE21120**# ISATE4112$**# ISATE5112$**# ISATE11160**# ISATE21160**# ISATE4116$**# ISATE5116$**# ISATE11200**# ISATE21200**# ISATE4120$**# ISATE5120$**# ISATH11250**# ISATH21250**# ISATH4125$**# ISATH5125$**# ISATV11320**# ISATV21320**# ISATV4132$**# ISATV5132$**# ISATV11400**# ISATV21400**# ISATV4140$**# ISATV5140$**# $ Please refer table 1 to replace $ at page-11 ** Please refer table 2 to replace ** at page-11 # Please refer table 3 to replace # at page-11 *** 4000 A, 4 Pole ACB is also available with 100% Neutral Pole (Price available on request) Note : Prices on request ACB range 630 A to 4000 A (IPR 3) 6
7 w.e.f. 1st August 2018 Industrial Switchgear Air Circuit Breaker (Conforms to IEC: / IS: ) ACB with Microprocessor Release IPR 1 (4 Pole) inbuilt O/L, S/C & E/F protection Current Rating Capacity Ordering Code Ordering Code MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISAFE11060**# ISAFE21060**# ISAFE4106$**# ISAFE5106$**# ISAFE11080**# ISAFE21080**# ISAFE4108$**# ISAFE5108$**# ISAFE11100**# ISAFE21100**# ISAFE4110$**# ISAFE5110$**# ISAFE11120**# ISAFE21120**# ISAFE4112$**# ISAFE5112$**# ISAFE11160**# ISAFE21160**# ISAFE4116$**# ISAFE5116$**# ISAFE11200**# ISAFE21200**# ISAFE4120$**# ISAFE5120$**# ISAFH11250**# ISAFH21250**# ISAFH4125$**# ISAFH5125$**# *** 100 ISAFV11320**# ISAFV21320**# ISAFV4132$**# ISAFV5132$**# *** 100 ISAFV11400**# ISAFV21400**# ISAFV4140$**# ISAFV5140$**# ACB with Microprocessor Release IPR 2 (3 Pole) inbuilt O/L, S/C & E/F protection with digital display Current Rating Capacity Ordering Code Ordering Code MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISATE12060**# ISATE22060**# ISATE4206$**# ISATE5206$**# ISATE12080**# ISATE22080**# ISATE4208$**# ISATE5208$**# ISATE12100**# ISATE22100**# ISATE4210$**# ISATE5210$**# ISATE12120**# ISATE22120**# ISATE4212$**# ISATE5212$**# ISATE12160**# ISATE22160**# ISATE4216$**# ISATE5216$**# ISATE12200**# ISATE22200**# ISATE4220$**# ISATE5220$**# ISATH12250**# ISATH22250**# ISATH4225$**# ISATH5225$**# ISATV12320**# ISATV22320**# ISATV4232$**# ISATV5232$**# ISATV12400**# ISATV22400**# ISATV4240$**# ISATV5240$**# ACB with Microprocessor Release IPR 2 (4 Pole) inbuilt O/L, S/C & E/F protection with digital display Current Rating Capacity Ordering Code Ordering Code MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISAFE12060**# ISAFE22060**# ISAFE4206$**# ISAFE5206$**# ISAFE12080**# ISAFE22080**# ISAFE4208$**# ISAFE5208$**# ISAFE12100**# ISAFE22100**# ISAFE4210$**# ISAFE5210$**# ISAFE12120**# ISAFE22120**# ISAFE4212$**# ISAFE5212$**# ISAFE12160**# ISAFE22160**# ISAFE4216$**# ISAFE5216$**# ISAFE12200**# ISAFE22200**# ISAFE4220$**# ISAFE5220$**# ISAFH12250**# ISAFH22250**# ISAFH4225$**# ISAFH5225$**# *** 100 ISAFV12320**# ISAFV22320**# ISAFV4232$**# ISAFV5232$**# *** 100 ISAFV12400**# ISAFV22400**# ISAFV4240$**# ISAFV5240$**# $ Please refer table 1 to replace $ at page-11 ** Please refer table 2 to replace ** at page-11 # Please refer table 3 to replace # at page-11 *** 4000 A, 4 Pole ACB is also available with 100% Neutral Pole (Price available on request) Note : Prices on request ACB range 630 A to 4000 A (IPR 3) 7
8 Industrial Switchgear w.e.f. 1st August 2018 Air Circuit Breaker (Conforms to IEC: / IS: ) ACB without Release (3 Pole) Current Ordering Code Ordering Code Rating Capacity MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISATE10060**# ISATE20060**# ISATE4006$**# ISATE5006$**# ISATE10080**# ISATE20080**# ISATE4008$**# ISATE5008$**# ISATE10100**# ISATE20100**# ISATE4010$**# ISATE5010$**# ISATE10120**# ISATE20120**# ISATE4012$**# ISATE5012$**# ISATE10160**# ISATE20160**# ISATE4016$**# ISATE5016$**# ISATE10200**# ISATE20200**# ISATE4020$**# ISATE5020$**# ISATH10250**# ISATH20250**# ISATH4025$**# ISATH5025$**# ISATV10320**# ISATV20320**# ISATV4032$**# ISATV5032$**# ISATV10400**# ISATV20400**# ISATV4040$**# ISATV5040$**# ACB without Release (4 Pole) Current Ordering Code Ordering Code Rating Capacity MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISAFE10060**# ISAFE20060**# ISAFE4006$**# ISAFE5006$**# ISAFE10080**# ISAFE20080**# ISAFE4008$**# ISAFE5008$**# ISAFE10100**# ISAFE20100**# ISAFE4010$**# ISAFE5010$**# ISAFE10120**# ISAFE20120**# ISAFE4012$**# ISAFE5012$**# ISAFE10160**# ISAFE20160**# ISAFE4016$**# ISAFE5016$**# ISAFE10200**# ISAFE20200**# ISAFE4020$**# ISAFE5020$**# ISAFH10250**# ISAFH20250**# ISAFH4025$**# ISAFH5025$**# *** 100 ISAFV10320**# ISAFV20320**# ISAFV4032$**# ISAFV5032$**# *** 100 ISAFV10400**# ISAFV20400**# ISAFV4040$**# ISAFV5040$**# ACB with Microprocessor Release IPR 1 (3 Pole) inbuilt O/L, S/C & E/F protection Current Ordering Code Ordering Code Rating Capacity MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISATS11060**# ISATS21060**# ISATS4106$**# ISATS5106$**# ISATS11080**# ISATS21080**# ISATS4108$**# ISATS5108$**# ISATS11100**# ISATS21100**# ISATS4110$**# ISATS5110$**# ISATS11120**# ISATS21120**# ISATS4112$**# ISATS5112$**# ISATS11160**# ISATS21160**# ISATS4116$**# ISATS5116$**# ISATS11200**# ISATS21200**# ISATS4120$**# ISATS5120$**# ACB with Microprocessor Release IPR 1 (4 Pole) inbuilt O/L, S/C & E/F protection Current Ordering Code Ordering Code Rating Capacity MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISAFS11060**# ISAFS21060**# ISAFS4106$**# ISAFS5106$**# ISAFS11080**# ISAFS21080**# ISAFS4108$**# ISAFS5108$**# ISAFS11100**# ISAFS21100**# ISAFS4110$**# ISAFS5110$**# ISAFS11120**# ISAFS21120**# ISAFS4112$**# ISAFS5112$**# ISAFS11160**# ISAFS21160**# ISAFS4116$**# ISAFS5116$**# ISAFS11200**# ISAFS21200**# ISAFS4120$**# ISAFS5120$**# $ Please refer table 1 to replace $ at page-11 ** Please refer table 2 to replace ** at page-11 # Please refer table 3 to replace # at page-11 *** 4000 A, 4 Pole ACB is also available with 100% Neutral Pole (Price available on request) Note : Prices on request ACB range 630 A to 4000 A (IPR 3)
9 w.e.f. 1st August 2018 Industrial Switchgear Air Circuit Breaker (Conforms to IEC: / IS: ) ACB with Microprocessor Release IPR 2 (3 Pole) inbuilt O/L, S/C & E/F protection with digital display Current Rating Capacity Ordering Code Ordering Code MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISATS12060**# ISATS22060**# ISATS4206$**# ISATS5206$**# ISATS12080**# ISATS22080**# ISATS4208$**# ISATS5208$**# ISATS12100**# ISATS22100**# ISATS4210$**# ISATS5210$**# ISATS12120**# ISATS22120**# ISATS4212$**# ISATS5212$**# ISATS12160**# ISATS22160**# ISATS4216$**# ISATS5216$**# ISATS12200**# ISATS22200**# ISATS4220$**# ISATS5220$**# ACB with Microprocessor Release IPR 2 (4 Pole) inbuilt O/L, S/C & E/F protection with digital display Current Rating Capacity Ordering Code Ordering Code MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISAFS12060**# ISAFS22060**# ISAFS4206$**# ISAFS5206$**# ISAFS12080**# ISAFS22080**# ISAFS4208$**# ISAFS5208$**# ISAFS12100**# ISAFS22100**# ISAFS4210$**# ISAFS5210$**# ISAFS12120**# ISAFS22120**# ISAFS4212$**# ISAFS5212$**# ISAFS12160**# ISAFS22160**# ISAFS4216$**# ISAFS5216$**# ISAFS12200**# ISAFS22200**# ISAFS4220$**# ISAFS5220$**# ACB Without Release (3 Pole) Current Rating Capacity Ordering Code Ordering Code MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISATS10060**# ISATS20060**# ISATS4006$**# ISATS5006$**# ISATS10080**# ISATS20080**# ISATS4008$**# ISATS5008$**# ISATS10100**# ISATS20100**# ISATS4010$**# ISATS5010$**# ISATS10120**# ISATS20120**# ISATS4012$**# ISATS5012$**# ISATS10160**# ISATS20160**# ISATS4016$**# ISATS5016$**# ISATS10200**# ISATS20200**# ISATS4020$**# ISATS5020$**# ACB Without Release (4 Pole) Current Rating Capacity Ordering Code Ordering Code MANUAL MANUAL ELECTRICAL ELECTRICAL (A) 415 V (ka) Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout ISAFS10060**# ISAFS20060**# ISAFS4006$**# ISAFS5006$**# ISAFS10080**# ISAFS20080**# ISAFS4008$**# ISAFS5008$**# ISAFS10100**# ISAFS20100**# ISAFS4010$**# ISAFS5010$**# ISAFS10120**# ISAFS20120**# ISAFS4012$**# ISAFS5012$**# ISAFS10160**# ISAFS20160**# ISAFS4016$**# ISAFS5016$**# ISAFS10200**# ISAFS20200**# ISAFS4020$**# ISAFS5020$**# $ Please refer table 1 to replace $ at page-11 ** Please refer table 2 to replace ** at page-11 # Please refer table 3 to replace # at page-11 Note : Prices on request ACB range 630A to 4000A (65kA) (IPR 3) 9
10 Industrial Switchgear w.e.f. 1st August 2018 Air Circuit Breaker (Conforms to IEC: / IS: ) 1. Microprocessor Based OCR (IPR) S.No. SAP Code Description 1-1 ISACX0172 IPR-E ISACX0214 IPR ISACX0173 IPR ISACX0199 IPR SACX0346 Communication software for IRP-3 Av. on request 2. Spring Charging Motor 3. Main CTs *1 S.No. SAP Code Description 2-1 ISACX0358 Charging Motor 110 V ISACX0147 Charging Motor 230 V S.No. SAP Code Description 3-1 ICELFACL018 CT 400 A ICELFACL001 CT 630 A ICELFACL002 CT 800 A ICELFACL003 CT 1000 A ICELFACL004 CT 1250 A ICELFACL005 CT 1600 A ICELFACL006 CT 2000 A ICELFACL007 CT 2500 A Neutral CTs *2 S.No. SAP Code Description 4-1 ICELFACL019 NCT 400 A ICELFACL012 NCT 630 A ICELFACL013 NCT 800 A ICELFACL014 NCT 1000 A ICELFACL015 NCT 1250 A ICELFACL016 NCT 1600 A ICELFACL017 NCT 2000 A ICELFACL021 NCT 2500 A Under Voltage Trip Device (UVT) S.No. SAP Code Description 5-1 ISACX VAC/DC ISACX VAC Shunt Trip / Closing Coil S.No. SAP Code Description 6-1 ISACX VDC ISACX VAC/DC ISACX VAC/DC ISACX VAC Key Lock / Key Interlock S.No. SAP Code Description 7-1 ISACX0353 Key lock (1 lock+1 key) ISACX0181 Key interlock (2 locks+1 keys) ISACX0210 Key interlock (3 locks+2 keys) ISACX0332 Castle Lock (1 lock+1 key) ISSACX0437 Castle Lock (2 lock+1 key) ISSACX0436 Castle Lock (3 lock+2 key) Adaptor Type Terminals (additional price) (6 nos. reqd. for 3 pole & 8 nos. for 4 pole ACB) S.No. SAP Code Description 8-1 SACP /800 A SACP /1250 A SACP A SACP A Other Accessories S.No. SAP Code Description 9-1 ISACX0301 On/Off Button cover ISACX0207 Spring charge indication switch ISACX0208 Door Interlook ISACX0349 Trip indication Switch ISACX0303 Mal Insertation prevention device ISACX0139 Aux. switch (5 c/o additional) ISACX0182 Position indication switch ISACX0302 Field test unit *1 For 3200 A & 4000 A rating ACBs 2 nos each of 1600 A & 2000 A CTs are use respectively in series on each pole. *2 This CT is required for GFT in 3 pole ACBs for 4 Pole ACBs main CTs is used as neutral CT. 10
11 w.e.f. 1st August 2018 Industrial Switchgear Air Circuit Breaker (Conforms to IEC: / IS: ) Table 1 Closing Coil & Charging Motor CC Voltage (V) CM Voltage (V) $ A B C D E F G H Table 3 Current Transformer # CT Rating is same as of ACB 0 (Zero) 400 A A 630 A B 800 A C 1000 A D 1250 A E 1600 A F 2000 A G 3200 A I 4000 A J Table 2 UVT & SHT UVT Voltage (V) SHT Voltage (V) ** (Zero one) (Zero Zero) *ACBs are supplied with following accessories as standard fitment: Manual Fixed Manual Drawout Electrical Fixed Electrical Drawout Aux. Contact 5CO Aux. Contact 5CO Aux. Contact 5CO Aux. Contact 5CO Safety Shutter Shunt Trip Device Safety Shutter Aux. Isolating contact unit Charging Motor Aux. Isolating contact unit Horizontal Terminals Closing Coil Horizontal Terminals Shunt Trip Device Charging Motor Closing Coil *Additional accessories except standard fitment are available on extra price. *Neutral CT is supplied as a standard fitment in 4 Pole ACBs. *Neutral CT prices are to be added for 3 Pole ACBs for ground fault protection. *All orders should be accompanied with ACB order form included in catalogue. 11
12 Industrial Switchgear w.e.f. 1st August 2018 Air Circuit Breaker (Conforms to IEC: / IS: ) ka ka ka ka MOTOR
13 w.e.f. 1st August 2018 Industrial Switchgear Air Circuit Breaker (Conforms to IEC: / IS: ) CUSTOMER / DEALER NAME ORDER NO. / DATE END USER NAME Rating ofacb 630 A 1000 A 1600 A 800 A 1250 A 2000 A 2500 A 3200 A 4000 A Qty. Series E S H V Numbers of Poles (100% Neutral) (50% Neutral for V-Series only) *Horizontal Terminals (H,V) Mounting Spring Charging Operation * Fixed Drawout Adaptor Terminals (for E&S series only) For E& S series - Horizontal terminals are standard, for H & V series vertical terminals are standard. Please specify if other combination is required. Closing Coil VAC/DC Manual Electrical Tripping Coil VAC/DC Motor V Without Release IPR E IPR 1 IPR 2 IPR 3 Release CT Rating A, Neutral CT Setting: O/L A, S/C A, Inst. A, GFT A, Note: Unless otherwise specified O/L will be set at maximum value and all other settings would be set at mid values. Close open cycle counter Field test unit Five c/o additional Aux. contacts Shunt Trip Coil Position Indication Switch UVT...V Other Accessories Spring Charge Indication Switch Mechanical Interlock Trip Indication Switch Key Lock Mal Insertion Prevention device Door Interlock Key Interlock 2L+1K 3L+2K OFV-6 Note : 1. Please specify the voltages for closing coil, shunt trip coil and UVT, available voltages are24 V DC, 110 VAC/DC, 220 VAC/DC and 415 V AC and for motor available voltages are 220 V AC/DC and 110 V AC/DC. 2. For details of Over current release, please refer the technical catalogue. 13
14 Industrial Switchgear w.e.f. 1st August 2018 Busbar Chambers Current Rating (A) Bus Bar Chamber Optima Ways Current Rating (A) Ways 63 A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way A ISBC way MOULDED CASE CIRCUIT BREAKERS (MCCB) SKB MCCBs-Adjustable type Ac 415 V, 50 hz conforms to iec:60947-ii/is:13947-ii Frame Thermal Setting Magnetic Setting Current Rating (A) Cap. Icu at 415 V Ics = 100% of Icu TP TP FP(Wsn) FP(Wsn) SKB-1 Fixed ka ISLAST ISLASF ISLAST ISLASF Ics = 75% of Icu SP SP SKB-1 Adjustable ka ISLASS**** Fixed % 125 ISLASS SKB ka ISLANS Adjustable Fixed 200 ISLANS % 250 ISLANS Ics = 75% of Icu TP TP FP(Wsn) FP(Wsn) SKB-1 SKB-2 SKB-3 Adjustable % Adjustable % Adjustable % Fixed ka ISLAST**** ISLASF**** /100 ISLAST0080/ ISLASF0080/ ISLAST ISLASF ka ISLANT**** ISLANF**** Fixed 80/100 ISLANT0080/ ISLANF0080/ ISLANT ISLANF ka ISLANT ISLANF Fixed 200 ISLANT ISLANF ISLANT ISLANF Adjustable ka ISLCNT ISLCNF Times 200 ISLCNT ISLCNF A 250 ISLCNT ISLCNF ISLCNT ISLCNF times 500 ISLCNT ISLCNF times 630 ISLCNT ISLCNF A 800 ISLCNT ISLCNF Ics = 50% of Icu TP TP FP(Wsn) FP(Wsn) Adjustable ka ISLCHT ISLCHF Times 200 ISLCHT ISLCHF SKB A 250 ISLCHT ISLCHF Adjustable ISLCHT ISLCHF % 4-10 times 500 ISLCHT ISLCHF times 630 ISLCHT ISLCHF ISLCHT ISLCHF Ics = 75% of Icu TP TP FP(Wsn) FP(Wsn) SKB-0 Adjustable % Adjustable* Interchange trip unit ka ISLDNT ISLDNT ISLDNT ****To be replaced by one of the Current Rating 0025 A / 0032 A / 0050 A / 0063A *For thermal/magnetic setting In SKB 1/2 25 A / 32 A / 40 A / 50 A / 63 A are without extended terminal however extended terminals are available on request at extra price for these ratings. 14
15 w.e.f. 1st August 2018 Industrial Switchgear MOULDED CASE CIRCUIT BREAKERS (MCCB) Adjustable thermal* & fixed magnetic setting (L Frame) Frame Capacity Icu at 415 V (ka) Current Rating (A) Ics = 100% of Icu TP TP FP (wsn) FP (wsn) 200 ISLLSEBT0200 # ISLLSEBF0200 # ISLLSEBT0250 # ISLLSEBF0250 # SKB ISLLSEBT0315 # ISLLSEBF0315 # ISLLSEBT0400 # ISLLSEBF0400 # ISLLSEBT0500 # ISLLSEBF0500 # ISLLSEBT0630 # ISLLSEBF0630 # Ics = 75% of Icu TP TP FP (wsn) FP (wsn) 200 ISLLNFBT0200 # ISLLNFBF0200 # ISLLNFBT0250 # ISLLNFBF0250 # SKB ISLLNFBT0315 # ISLLNFBF0315 # ISLLNFBT0400 # ISLLNFBF0400 # ISLLNFBT0500 # ISLLNFBF0500 # ISLLNFBT0630 # ISLLNFBF0630 # Adjustable thermal & adjustable magnetic setting (L Frame) Frame Frame Size Capacity Icu at 415 V (ka) Magnetic/ Thermal Setting Current Rating (A) Current Rating (A) Cap. Icu at 415 V Ics = 100% of Icu TP TP FP (wsn) FP (wsn) 200 ISLLSECT0200 # ISLLSECF0200 # ISLLSECT0250 # ISLLSECF0250 # SKB ISLLSECT0315 # ISLLSECF0315 # ISLLSECT0400 # ISLLSECF0400 # ISLLSECT0500 # ISLLSECF0500 # ISLLSECT0630 # ISLLSECF0630 # Ics = 75% of Icu TP TP FP (wsn) FP (wsn) 200 ISLLNFCT0200 # ISLLNFCF0200 # ISLLNFCT0250 # ISLLNFCF0250 # SKB ISLLNFCT0315 # ISLLNFCF0315 # ISLLNFCT0400 # ISLLNFCF0400 # ISLLNFCT0500 # ISLLNFCF0500 # ISLLNFCT0630 # ISLLNFCF0630 # *Adjustable thermal (80-100%) #All MCCBs are with extended terminals Ics = 100% of Icu SP SP ka ISLGSS**** SKB-5 Fixed 125 ISLGSS ISLGSS ISLGSS Ics = 100% of Icu TP TP FP (wsn) FP (wsn) ka ISLGST**** ISLGSF**** SKB-5 Fixed 80/100 ISLGST0080/ ISLGSF0080/ ISLGST ISLGSF ISLGST0150/ ISLGSF0150/ Ics = 75% of Icu SP SP SKB-6 Fixed ka ISLGNS**** ISLGNS Ics = 75% of Icu TP TP FP (wsn) FP (wsn) ka ISLGNT**** ISLGNF**** SKB-6 Fixed 80/100 ISLGNT0080/ ISLGNF0080/ ISLGNT ISLGNF ISLGNBAT0150/ ISLGNBAF0150/ Ics = 50% of Icu TP TP FP (wsn) FP (wsn) ka ISLGHT**** ISLGHF**** /100 ISLGHT0080/ ISLGHF0080/ SKB-7 Fixed 125 ISLGHT ISLGHF ISLGHT ISLGHF ISLGHT ISLGHF Ics = 100% of Icu TP TP FP (wsn) FP (wsn) ka ISLFNT**** ISLFNF**** /100 ISLFNT0080/ ISLFNF0080/ SKB-8 Fixed 125 ISLFNT ISLFNF ISLFNT ISLFNF ISLFNT ISLFNF ISLFNT ISLFNF ka ISLFHT**** ISLFHF**** /100 ISLFHT0080/ ISLFHF0080/ SKB-9 Fixed 125 ISLFHT ISLFHF ISLFHT ISLFHF ISLFHT ISLFHF ISLFHT ISLFHF **** To be replaced by one of the current rating 0025 A / 0032 A / 0050 A / 0063 A in SKB 5/6/7 25 A / 32 A / 40 A / 50 A / 63 A are without extended terminal however extended terminals are available on request at extra price for these ratings. 15
16 Industrial Switchgear w.e.f. 1st August 2018 MOULDED CASE CIRCUIT BREAKERS (MCCB) easybreak frame: Fixed thermal & fixed magnetic setting : Ics = 50% of Icu Execution Current Frame Cap. Icu Rating Three Pole Size at 415 V (A) 63 ISLMLAAT ISLMLAAT Easybreak 10 ka 100 ISLMLAAT ISLMLAAT MOULDED CASE CIRCUIT BREAKERS (MCCB) Fixed thermal & fixed magnetic setting Ics = 50% of Icu Execution Current Frame Cap. Icu Rating Three Pole Size at 415 V (A) 15 ISLSHAAT ISLSHAAT SKB 5A 10 ka 32 ISLSHAAT ISLSHAAT MCCB Enclosures General Purpose Enclosures S.No. Description* ACCESSORIES CAT. NO. CAT. No. ` Per 1 Easybreak Frame TP ISEMTP SKB 5/6/7 Frame TP ISEGTP SKB 5/6/7 Frame FP ISEGFP SKB 1/2 Frame TP ISEATP SKB 1/2 Frame FP ISEAFP SKB 8/9 Frame TP ISEFTP SKB 8/9 Frame FP ISEFFP SKB 3/4 Frame TP (400A) ISECTP SKB 3/4 Frame FP (400A) ISECFP SKB 3/4 Frame TP (800A) ISECTS SKB 3/4 Frame TP (800A) ISECTS SKB 10/11 Frame TP ISELTP SKB 10/11 Frame FP ISELFP CAT. No. CAT. No. CAT. No. CAT. No. SKB/5/6/7 SKB1/2 SKB8/9 SKB 3/4 SKB 0 SKB 10/11 HSN Code: 8538 Shunt Trip Vac ISLGS ISLAS ISLLSF ISLCS ISLLSTD ISLLS Vac ISLGS ISLAS ISLLSF ISLCS ISLLSTD ISLLS Vac ISLGS ISLAS ISLLSF ISLCS ISLLSTD ISLLS Under Voltage Release Vac ISLGU ISLAU ISLUVRF ISLCU ISLUVRD ISLLU Vac ISLGU ISLAU ISLUVRF ISLCU ISLUVRD ISLLU Vac ISLGU ISLAU ISLUVRF ISLCU ISLUVRD ISLLU Auxillary Contact (250Vac/250Vdc) (450Vac/250Vdc) 1-Changeover ISLLASG1CO ISLLASA1CO ISLLASF1CO ISLLASC1CO ISLLASD1CO ISLLA1CO Changeover ISLLASG2CO ISLLASA2CO ISLLASF2CO ISLLASC2CO ISLLASD2CO ISLLA2CO Rotary Handle Direct Mounting ISLGD ISLAD ISLLRRHF ISLLRRHC ISLLRRHD ISLLRN Door Mounting ISLGRN ISLARN Trip Alarm Contact (Factory Fitted ISLLALG1CO ISLLALA1CO ISLLALF1CO ISLLALC1CO* ISLLAB Back Studs - - ISLLBSA250 on req. - - ISLLBSC### on req Note : Following additional accessories are available on request : - Terminal Shrouds for G A F frame - Dolly Pad Lock for G A F C & L frame - Factory fitted Castell Lock available in C and D frame - Back Studs (Price on Request) *Factory Fitted Only # - Replace # with rating 16
17 w.e.f. 1st August 2018 Industrial Switchgear Digital Moulded Case Circuit Breaker (AC 415) : Ics = 100% of Icu with adjustable microprocessor release) (Conforms to IEC: II/IS:13947-II) Capacity Icu at 415 V Current Rating (A) Frame TP TP FP (wsn) FP (wsn) 25 ISLFENT ISLFENF ISLFENT ISLFENF ISLFENT ISLFENF ISLFENT ISLFENF ISLFENT ISLFENF ka 80 FEN ISLFENT ISLFENF ISLFENT ISLFENF ISLFENT ISLFENF ISLFENT ISLFENF ISLFENT ISLFENF ISLFENT ISLFENF *Adjustable thermal (40%-100%) & adjustable magnetic (6-10 times of Lr) Digital Moulded Case Circuit Breaker (AC 415) : Ics = 75% of Icu with adjustable microprocessor release) (Conforms to IEC: II/IS:13947-II) Capacity Icu at 415 V Current Rating (A) Frame 50 ka TP TP FP (wsn) FP (wsn) 25 ISLFEHT ISLFEHF ISLFEHT ISLFEHF ISLFEHT ISLFEHF ISLFEHT ISLFEHF ISLFEHT ISLFEHF FEH ISLFEHT ISLFEHF ISLFEHT ISLFEHF ISLFEHT ISLFEHF ISLFEHT ISLFEHF ISLFEHT ISLFEHF ISLFEHT ISLFEHF Digital Moulded Case Circuit Breaker (AC 415) with adjustable microprocessor release) (Conforms to IEC: II/IS:13947-II) Capacity Icu at 415 V Ics = 100% of Icu 36kA Ics = 75% of Icu 50kA Current Rating (A) 250 Frame TP TP FP (wsn) FP (wsn) ISLLSEET0250 # ISLLSEEF0250 # ISLLSEET0320 # ISLLSEEF0320 # LES ISLLSEET0400 # ISLLSEEF0400 # ISLLSEET0500 # ISLLSEEF0500 # ISLLSEET0630 # ISLLSEEF0630 # ISLLNFET0250 # ISLLNFEF0250 # ISLLNFET0320 # ISLLNFEF0320 # LEN ISLLNFET0400 # ISLLNFEF0400 # ISLLNFET0500 # ISLLNFEF0500 # ISLLNFET0630 # ISLLNFEF0630 # *Adjustable thermal (40%-100%) & adjustable magnetic (6-10 itmes of In) # Extended terminal in L frame from (250 A A) 17
18 Industrial Switchgear w.e.f. 1st August 2018 SHIP Series : Adjustable thermal & fixed magnetic setting Ics = 100% of Icu Capacity Icu Current Rating Frame Icu at at 415 V (A) 240 V (ka) 27 ka SP SP DP DP 40 ISA13DBS ISA13DBD ISA13DBS ISA13DBD ISA13DBS ISA13DBD HID1 ISA13DBS ISA13DBD ISA13DBS ISA13DBD ISA13DBS ISA13DBD ISA13DBS ISA13DBD SHIP Series : Adjustable thermal & fixed magnetic setting Ics = 100% of Icu Capacity Icu Current Rating Frame at 415 V (A) 27 ka TP TP FP FP 40 ISA13DBT ISA13DBF ISA13DBT ISA13DBF ISA13DBT ISA13DBF HID1 ISA13DBT ISA13DBF ISA13DBT ISA13DBF ISA13DBT ISA13DBF ISA13DBT ISA13DBF SHIP Series : Adjustable thermal & fixed magnetic setting Ics = 100% of Icu Capacity Icu Current Rating Frame Icu at at 415 V (A) 240 V (ka) 36 ka SP SP DP DP 40 ISA13DBS ISA13DBD ISA13DBS ISA13DBD ISA13DBS ISA13DBD HID1 ISA13DBS ISA13DBD ISA13DBS ISA13DBD ISA13DBS ISA13DBD ISA13DBS ISA13DBD SHIP Series : Adjustable thermal & fixed magnetic setting Ics = 100% of Icu Capacity Icu Current Rating Frame at 415 V (A) 36 ka TP TP FP FP 40 ISA13DBT ISA13DBF ISA13DBT ISA13DBF ISA13DBT ISA13DBF HID1 ISA13DBT ISA13DBF ISA13DBT ISA13DBF ISA13DBT ISA13DBF ISA13DBT ISA13DBF
19 w.e.f. 1st August 2018 Industrial Switchgear EASYBREAK 1 : Adjustable thermal & fixed magnetic setting Ics = 100% of Icu Capacity Icu Current Rating Frame Icu at at 415 V (A) 240 V (ka) 10 ka SP SP DP DP 40 ISLE1AAS ISLE1AAD ISLE1AAS ISLE1AAD ISLE1AAS ISLE1AAD E1 ISLE1AAS0080# ISLE1AAD0080# ISLE1AAS0100# ISLE1AAD0100# ISLE1AAS0125# ISLE1AAD0125# ISLE1AAS0160# ISLE1AAD0160# EASYBREAK 1 : Adjustable thermal & fixed magnetic setting Ics = 100% of Icu Capacity Icu Current Rating Frame at 415 V (A) 10 ka TP TP FP FP 40 ISLE1ABT ISLE1ABF ISLE1ABT ISLE1ABF ISLE1ABT ISLE1ABF E1 ISLE1ABT0080# ISLE1ABF0080# ISLE1ABT0100# ISLE1ABF0100# ISLE1ABT0125# ISLE1ABF0125# ISLE1ABT0160# ISLE1ABF0160# EARTH FAULT RELAY FOR MCCBs MCCB Current Range (A) ` Per ISEF ISEF ISEF ISEF # The above prices are inclusive of CT S ** For operating the Earth Fault Relay a Shunt trip or an UVR has to be used. Note: *For operating Shunt Trip for G Frame, a separate auxiliary switch would be required in which case one c/o. will be used with the shunt trip, leaving one c/o. free for use. Door mounting clamps for G & AA Frame are supplied free of cost on request bases. 19
20 Industrial Switchgear w.e.f. 1st August 2018 mccb panel boards G Frame Panel Boards, O/G TP MCCBs G-Frame Incomer** Outgoing* (No. of Ways) Single Door Double Door ` Per 2 Way ISVG ISVG A AA Frame MCCB 4 Way ISVG ISVG Way ISVG ISVG Way ISVG ISVG Way ISVG ISVG Way ISVG ISVG Way ISLG ISLG A LS Frame MCCB 4 Way ISLG ISLG Way ISLG ISLG Way ISLG ISLG Way ISLG ISLG Way ISLG ISLG Way ISVG ISVG A CN Frame MCCB 4 Way ISVG ISVG Way ISVG ISVG Way ISVG ISVG Way ISVG ISVG Way ISVG ISVG * The outgoings number of ways is the number of G Frame TP MCCBs that can be mounted. In case of SP MCCBs the number of MCCBs shall be three times the number of ways in TP MCCBs. ** Maximum ratings are indicated for the incoming MCCBs however lower ratings in the same frame can be ordered. The above prices are for bare enclosures only, incoming and outgoing MCCBs have to be ordered separately. 3 pole Cable Alley A Frame I / C & G frame O/G S. No. Description* Single Door ` Per Double Door ` Per 1 Cable Alley I/C AF 250 A O/G 3P GF 2 way ISSBOU ISSBOU Cable Alley I/C AF 250 A O/G 3P GF 4 way ISSBOU ISSBOU Cable Alley I/C AF 250 A O/G 3P GF 6 way ISSBOU ISSBOU Cable Alley I/C AF 250 A O/G 3P GF 8 way ISSBOU ISSBOU Cable Alley I/C AF 250 A O/G 3P GF 12 way ISSBOU ISSBOU Cable Alley I/C AF 250 A O/G 3P GF 16 way ISSBOU ISSBOU pole Cable Alley C Frame I/C & G frame O/G S. No. Description* Single Door ` Per Double Door ` Per 1 Cable Alley I/C CF 400 A O/G 3P GF 2 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 3P GF 4 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 3P GF 6 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 3P GF 8 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 3P GF 12 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 3P GF 16 way ISSBOU ISSBOU pole Cable Alley L Frame I/C & G frame O/G S. No. Description* Single Door ` Per Double Door ` Per 1 Cable Alley I/C L Fr 400 A O/G 3P GF 2 way ISSBOU ISSBOU Cable Alley I/C L Fr 400 A O/G 3P GF 4 way ISSBOU ISSBOU Cable Alley I/C L Fr 400 A O/G 3P GF 6 way ISSBOU ISSBOU Cable Alley I/C L Fr 400 A O/G 3P GF 8 way ISSBOU ISSBOU Cable Alley I/C L Fr 400 A O/G 3P GF 12 way ISSBOU ISSBOU Cable Alley I/C L Fr 400 A O/G 3P GF 16 way ISSBOU ISSBOU
21 w.e.f. 1st August 2018 Industrial Switchgear mccb panel boards G Frame Panel Boards, O/G FP MCCBs G-Frame Incomer** Outgoing* (No. of Ways) Single Door Double Door 2 Way ISVGF ISVGF A AA Frame MCCB 4 Way ISVGF ISVGF Way ISVGF ISVGF Way ISVGF ISVGF Way ISVGF ISVGF Way ISLGF ISLGF A LS Frame MCCB 4 Way ISLGF ISLGF Way ISLGF ISLGF Way ISLGF ISLGF Way ISLGF ISLGF Way ISVGF ISVGF A CN Frame MCCB 4 Way ISVGF ISVGF Way ISVGF ISVGF Way ISVGF ISVGF Way ISVGF ISVGF * The outgoings number of ways is the number of G Frame FP MCCBs that can be mounted. In case of SP MCCBs the number of MCCBs shall be four times the number of way in FP O/G MCCBs. ** Maximum ratings are indicated for the incoming MCCBs however lower ratings in the same frame can be ordered. The above prices are for bare enclosures only, incoming and outgoing MCCBs have to be ordered separately. 4 pole Cable Alley A Frame I/C & G Frame O/G S. No. Description* Single Door ` Per Double Door ` Per 1 Cable Alley I/C AF 250 A O/G 4P GF 2 way ISSBOU ISSBOU Cable Alley I/C AF 250 A O/G 4P GF 4 way ISSBOU ISSBOU Cable Alley I/C AF 250 A O/G 4P GF 6 way ISSBOU ISSBOU Cable Alley I/C AF 250 A O/G 4P GF 8 way ISSBOU ISSBOU Cable Alley I/C AF 250 A O/G 4P GF 12 way ISSBOU ISSBOU pole Cable Alley C Frame I/C & G Frame O/G S. No. Description* Single Door ` Per Double Door ` Per 1 Cable Alley I/C CF 400 A O/G 4P GF 2 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 4P GF 4 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 4P GF 6 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 4P GF 8 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 4P GF 12 way ISSBOU ISSBOU pole Cable Alley L Frame I/C & G frame O/G S. No. Description* Single Door ` Per Double Door ` Per 1 Cable Alley I/C L Fr 400 A O/G 4P GF 2 way ISSBOU ISSBOU Cable Alley I/C L Fr 400 A O/G 4P GF 4 way ISSBOU ISSBOU Cable Alley I/C L Fr 400 A O/G 4P GF 6 way ISSBOU ISSBOU Cable Alley I/C L Fr 400 A O/G 4P GF 8 way ISSBOU ISSBOU Cable Alley I/C L Fr 400 A O/G 4P GF 12 way ISSBOU ISSBOU
22 Industrial Switchgear w.e.f. 1st August 2018 mccb panel boards A Frame Panel Boards, O/G TP MCCBs A FRAME Incomer** Outgoing* (No. of Ways) Single Door ` Per Double Door ` Per 400 A LS Frame MCCB 400 A CN/CH Frame MCCB 630 A CN/CH Frame MCCB 800 A CN/CH Frame MCCB 6 Way ISLA ISLA Way ISLA ISLA Way ISLA ISLA Way ISVA ISVA Way ISVA ISVA Way ISVA ISVA Way ISVA ISVA Way ISVA ISVA Way ISVA ISVA Way ISVA ISVA Way ISVA ISVA Way ISVA ISVA * The outgoings number of ways is the number of A Frame TP MCCBs that can be mounted. ** Maximum ratings are indicated for the incoming MCCBs however lower ratings in the same frame can be ordered. The above prices are for bare enclosures only, incoming and outgoing MCCBs have to be ordered separately. 3 Pole Cable Alley C Frame I/C & A Frame O/G S. No. Description* Single Door ` Per Double Door ` Per 1 Cable Alley I/C CF 400 A O/G 3P AF 6 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 3P AF 8 way ISSBOU ISSBOU Cable Alley I/C CF 400 A O/G 3P AF 12 way ISSBOU ISSBOU Cable Alley I/C CF 630 A O/G 3P AF 6 way ISSBOU ISSBOU Cable Alley I/C CF 630 A O/G 3P AF 8 way ISSBOU ISSBOU Cable Alley I/C CF 630 A O/G 3P AF 12 way ISSBOU ISSBOU Pre-Wired Meter Module with Voltmeter, Ammeter, Selector Switch, Ct s Control Fuse & Indicating Lights S. No. Description Single Door ` Per Double Door ` Per 1 Prewire Meter Module - Analog ISSBOU ISSBOU Meter Module - Digital ISSBOU ISSBOU
23 w.e.f. 1st August 2018 Industrial Switchgear Bare Meter Module / mcb Module / Add on Module S. No. Description Single Door ` Per Double Door ` Per 1 Meter Module - Analog Provision for Ammeter Voltmeter - Analog with selector switch ISSBOU ISSBOU MCB Module ISSBOU ISSBOU Add on Module ISSBOU ISSBOU * Ammeter, Voltmeter, Selector Switch, Control Fuses, Indicating Lights, MCBs etc. have to be ordered separately and are at extra cost. ** The above prices are for bare module enclosures only. Add on Incoming Changeover Switch Enclosure S. No. Description A Incoming change Over switch-f1 ISSBOU A & 630A Incoming change Over switch - F2 ISSBOU A Incoming change Over switch - F3 ISSBOU * Ammeter, Voltmeter, Selector Switch, Control Fuses, Indicating Lights, MCBs etc. have to be ordered separately and are at extra cost. 23
24 Industrial Switchgear w.e.f. 1st August 2018 switch DISCONNECTOR FUSE (Cubicle) Switch Disconnector Fuse (Suitable for Bolted Fuses)- 3 Pole & Neutral (Cubicle with hbc fuse) 415 V, 50Hz, AC 23A, Conforms to IS: Rating (A) Type of Fuses (BS) Open Execution (O/E) Type with HBC Fuse Std. Packing (No. of /s) Std. Packing (No. of /s) With Sheet Steel Enclosure ` Per with HBC Fuse 32 STIA FSHF ISFDTF N ISFDTW N STIS FSHF ISFDTF N ISFDTW N STCP*/STC FSHF ISFCTF N ISFCTW N STCP*/STC FSHF ISFCTF N ISFCTW N STF FSHF ISFCTF N ISFCTW N STF FSHF ISFCTF N ISFCTW N STKF FSHF ISFCTF N ISFCTW N STKF FSHF ISFCTF N ISFCTW N STMF FSHF ISFCTF N ISFCTW N STLM FSHF ISFCTF N ISFCTW N STLM FSHF ISFCTF N ISFCTW N *STCP to be used for compact design switch only. SDF - 3 pole & NEutral (Suitable for DIN Fuses) With HBC Fuse 415 V, 50 Hz, AC 23 A, Conforms to IS: Rating (A) Type of Fuses (BS) Type Open Execution (O/E) with 3 Fuses ` Per Std. Packing (No. of with HBC /s) Fuse Std. Packing (No. of /s) with HBC Fuse With Sheet Steel Enclosure with 3 Fuses 32 SB00 FSHF ISFFTF N ISFFTW N SB00 FSHF ISFFTF N ISFFTW N SB00 FSHF ISFFTF N ISFFTW N SB00 FSHF ISFFTF N ISFFTW N SB01 FSHF ISFKTF N ISFKTW N SB01 FSHF ISFKTF N ISFKTW N SB01 FSHF ISFKTF N ISFKTW N SB02 FSHF ISFKTF N ISFKTW N SB02 FSHF ISFKTF N ISFKTW N SB03 FSHF ISFKTF N ISFKTW N *800 SB03 FSHF ISFKTF N ISFKTW N *800A SDF (with E/C & W/O) din type will be supplied without HRC Fuses. SDF - 4 Pole (Open Execution) O/E With HBC Fuse 415 V, 50Hz, AC 23A, Conforms to IS: Rating (A) Type of Fuses (BS) Suitable for Bolted Fuses Type with HBC Fuse Std. Packing (No. of /s) Suitable for DIN Fuse Std. Packing (No. of /s) with HBC Fuse 32 STIA FSHF ISFDFF N ISKFFF N STIS FSHF ISFDFF N ISKFFF N STCP*/STC FSHF ISFDFF N ISKFFF N STCP*/STC FSHF ISFDFF N ISKFFF N STF FSHF ISFSFF N ISFKFF N STF FSHF ISFSFF N ISFKFF N STKF FSHF ISFSFF N ISFKFF N STKF FSHF ISFSFF N ISFKFF N STMF FSHF ISFSFF N ISFKFF N STLM FSHF ISFSFF N ISFKFF N FSHF ISFSFF N ISFKFF N *STCP to be used for compact design switch only. 24
25 w.e.f. 1st August 2018 Industrial Switchgear DMC FUSE BASES DMC FUSE BASES FOR KNIFE TYPE HBC FUSE LINKS, (CONFORMS:IEC: & 2-1/IS: & 2-1) Rating (A) Type Std. Packing (No. of /s) 100 SFB-00 ISUC00O SFB-00 ISUC00O SFB-00 ISUC00O SFB-01 ISIC01O SFB-02 ISIC02O SFB-03 ISIC03O HBC FUSE LINKS - BOLTED TYPE HBC FUSE LINKS - BOLTED TYPE BREAKING CAPACITY>80KA, 415 V, 50Hz, CONFORMS: IEC: & 2-1/IS: & 2-1 Rating (A) Type of Tag Type Std. Packing (No. of /s) ` Per 2, 4, 6, 10, 16 OFFSET SNS ISHNS , 25, 32 OFFSET SNS ISHNS , 10, 16, 20, 25, 32 OFFSET STIA ISHTIA , 50, 63 OFFSET STIS ISHTIS , 100, 125 CENTRAL STC ISHTC , 100, 125 OFFSET STCP ISHTCP , 160, 200 CENTRAL STF ISHTF , 300, 315 CENTRAL STKF ISHTKF CENTRAL STMF ISHTMF , 500 CENTRAL STTS ISHTTS , 500 CENTRAL STTM ISHTTM CENTRAL STLM ISHTLM CENTRAL STLM ISHTLM , 6, 10 CYLINDRICAL SLHF ISHRH , 20, 32, 40 CYLINDRICAL SLHF ISHRH CYLINDRICAL SLHF ISHRH CYLINDRICAL SLHF ISHRH *Under ratings in STIA, STIS, STC & STCP available on request. hbc fuse Link - DIN TYPE KNIFE (DIN) TYPE BREAKING CAPACITY >80 ka, 415 V, 50 Hz, (CONFORMS: IEC: & 2-1/IS: & 2-1) Rating (A) Type Std. Packing (No. of /s) ` Per 6, 10, 16, 20, 25, 32 SB00 ISHCD , 63, 80, 100 SB00 ISHCD SB00 ISHCD SB00 ISHCD , 50, 63, 80, 100, 125 SB01 ISHCD , 200 SB01 ISHCD SB01 ISHCD , 250, 315 SB02 ISHCD SB02 ISHCD SB03 ISHCD , 630 SB03 ISHCD
26 Industrial Switchgear w.e.f. 1st August 2018 stanguard Switch Disconnector 3 Pole - stanguard Switch Disconnector, 415 V Conforms to IS:13947 (Part -3); IEC: Frame Size Current Rating (A) Open Execution Cat. Code ` Per SS Enclosure Cat. Code 0 80 ISCSTO ISCSTE ISCSTO ISCSTE ISCSTO ISCSTE ISCSTO ISCSTE ISCSTO ISCSTE ISCSTO ISCSTE ISCSTO ISCSTE ISCSTO ISCSTE Pole - stanguard Switch Disconnector, 415 V Conforms to IS:13947 (Part -3); IEC: Frame Size Current Rating (A) Open Execution Cat. Code ` Per SS Enclosure Cat. Code ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE ISCSFO ISCSFE stanguard ON LOAD CHANGEOVER stanguard on-load changeover with advance neutral AC23A-CATEGORY 415 V, 50Hz, CONFORMS TO IS: Rating (A) Frame Size Type Open Execution-FP(O/E) ` Per ` Per With Sheet Steel Enclosure (W/E) SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE SGCOS ISCNFO ISCNFE Note: Phase barrier & handle with door interlock kit are integral part of the changeover switch ACCESSORIES FOR STANGUARD ONLOAD CHANGEOVER SWITCH Aux. Contacat 1 NO + 1 NC ISCNFAC1CO NO + 2 NC ISCNFAC2CO
27 w.e.f. 1st August 2018 Industrial Switchgear stanguard FP BY PASS switch stanguard FP by pass switch CONFORMS TO IS: (Part 3), IEC: Rating (A) Frame Size Open Execution-FP(O/E) ISCBFO ISCBFO ISCBFO ISCBFO ISCBFO ISCBFO ISCBFO ISCBFO ISCBFO ISCBFO ISCBFO ISCBFO Automatic transfer Switch Automatic transfer Switch (Conforms to IEC: and IEC: ) Three / Four Pole, AC-31 A, 50 Hz, 415 V Automatic/Manual with inbuilt Time delay Rating (A) Open Execution 3P Three Pole 4P Four Pole 100 ISYTCDO ISYFCDO ISYTCDO ISYFCDO ISYTCDO ISYFCDO ISYTCDO ISYFCDO ISYTCDO ISYFCDO ISYTCDO ISYFCDO ISYTCDO ISYFCDO ISYTCDO ISYFCDO ISYTCDO ISYFCDO With Enclosure 100 ISYTCDE ISYFCDE ISYTCDE ISYFCDE ISYTCDE ISYFCDE ISYTCDE ISYFCDE ISYTCDE ISYFCDE ISYTCDE ISYFCDE ISYTCDE ISYFCDE ISYTCDE ISYFCDE ISYTCDE ISYFCDE
28 w.e.f. 1st August 2018 CONVENTIONAL PRODUCT 28
29 w.e.f. 1st August 2018 ON-LOAD CHANGEOVER SWITCHES Onload Changeover Switch - AC 23 (side handle) in sheet enclosure, 415 V AC, 50 Hz. Industrial Switchgear Rating (A) Type 240 V Double Pole Std. Packing (No. of /s) ` Per 32 SCHS ISCFDE N SCHS ISCFDE N V Four Pole 16 SCHS ISCFFE N SCHS ISCFFE N SCHS ISCFFE N SCHS ISCFFE N OFF-LOAD CHANGEOVER SWITCHES Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415 V AC, 50 Hz. Rating (A) Type Std. Packing (No. of /s) ` Per 200 SCHS ISCFFE N SCHS ISCFFE N SCHS ISCFFE N SCHS ISCFFE N SCHS ISCFFE N SCHS ISCFFE N SCHS ISCFFE N SCHS ISCFFE N SCHS ISCFFE N Double Break Fuse Switch s Double Break Fuse Switch s (with HBC Fuse) IN SHEET STEEL ENCLOSURES 415 V, 50 Hz, (CONFORMS: IS / IEC & 3) Rating (A) Type of Fuse Type ` Per with HBC fuse Std. Packing (No. of /s) ` Per with HBC fuse Triple Pole & Neutral Pole Four Pole 63 STIS FSH ISFNTW N ISFNFW STCP FSH ISFNTW N ISFNFW STF FSH ISFNTW N ISFNFW STKF FSH ISFNTW N ISFNFW STMF FSH ISFNTW N ISFNFW STTM FSH ISFNTW N STLM FSH ISFNTW N - -
30 Industrial Switchgear w.e.f. 1st August 2018 REWIRABLE SWICH FUSE UNITS REWIRABLE SWICH FUSE UNITS 240 V / 415 V, 50 Hz, AC 23 A, (CONFORMS: IS/IEC & 3) Rating (A / V) Type of Fuse Type Std. Packing (No. of /s) ` Per Single Pole & Neutral 16 A / 240 V- Side Handle version - SHF ISSRSE N A / 240 V - SHF ISSRSE N A / 240 V - SHF ISSRSE N Double Pole 16 A / 240 V - SHF ISSRDE N A / 240 V - SHF ISSRDE N A / 415 V - SHF ISSRDE N A / 415 V - SHF ISSRDE N Triple Pole & Neutral 16 A / 415 V - SHF ISSRTE N A / 415 V - SHF ISSRTE N A / 415 V (Standard) - SHF ISFRTE N A / 415 V (Standard) - SHF ISFRTE N A / 415 V - SHF ISSRTE N A / 415 V - SHF ISSRTE N HRC Type-Double Pole 32 A / 415 V STIA SHF(H) ISSHDE N A / 415 V STIS SHF(H) ISSHDE N HRC Type-Triple Pole & Neutral 16 A / 415 V SNS SHF(H) ISSHTE N A / 415 V STIA SHF(H) ISSHTE N A / 415 V STIS SHF(H) ISSHTE N A / 415 V STCP SHF(H) ISSHTE N Kit Kat Rewireable Kit Kat Rewireable - Porcelain Fuse carrier & Base (Conforms to IS: 2086) Rating (A) Std. Packing (No. of /s) HSN Code: 8538 ` Per Amperes / Volt 16 A / 240 V ISKKRN N A / 415 V ISKKRN N A / 240 V ISKKRN N A / 415 V ISKKRN N A / 415 V * ISKKRN N A / 415 V # ISKKDN N A / 415 V * ISKKRN N A / 415 V # ISKKDN N A / 415 V * ISKKRN N A / 415 V ** ISKKRT N A / 415 V * ISKKRN N A / 415 V ** ISKKRT N * - Standard, # - Deluxe, ** - With Extension strips 30
Domestic & Industrial Switchgear. Switchgear
Domestic & Industrial Switchgear Switchgear PRICE LIST w.e.f. 1st Aug., 2014 Distribution Boards Switchgear Electrical energy has brought along with it a lot of conveniences, beyond imagination. It s consumption
More informationDomestic & Industrial Switchgear. Switchgear
Domestic & Industrial Switchgear Switchgear PRICE LIST w.e.f. 2 nd Nov. 2011 Switchgear Distribution Boards Electrical energy has brought along with it a lot of conveniences, beyond imagination. It s consumption
More informationDomestic & Industrial Switchgear. Switchgear
Domestic & Industrial Switchgear Switchgear PRICE LIST w.e.f. st April 0 Distribution Boards Switchgear Electrical energy has brought along with it a lot of conveniences, beyond imagination. It s consumption
More informationThe young energy ensures more safety
The young energy ensures more safety Domestic Products Catalogue 2017 CORPORATE OFFICE ABOUT STANDARD STANDARD is a brand of India s leading FMEG company, Havells India Ltd., that offers a wide range of
More informationThe young energy ensures more safety
The young energy ensures more safety Domestic Products Catalogue 2017 CORPORATE OFFICE ABOUT STANDARD STANDARD is a brand of India s leading FMEG company, Havells India Ltd., that offers a wide range of
More informationDomestic & Industrial Switchgear
LOAD LINE CM/L-8959719 240V 50Hz I-ON 10000 3 Domestic & Industrial Switchgear Miniature Circuit Breaker IS/IEC 60898-1 DSMSCSPF040 Price List April 2015 2 CORPORATE OFFICE About STANDARD STANDARD is a
More informationIndustrial Circuit Protection
Industrial Circuit Protection PRICE LIST w.e.f. 1st July, 2017 Contents Industrial Switchgear - Titania Air Circuit Breaker 5-13 - Loadline Moulded Case Circuit Breaker 14-21 - Loadline Digital Moulded
More informationIndustrial Circuit Protection
Industrial Circuit Protection LIST PRICE : w.e.f. 2 nd July, 2018 Note: All Switchgear and Controlgear Products to be billed at 18% *GST *Subject to change as per Govt. Notificaiton Contents Industrial
More informationAN ISO 9001:2015 COMPANY
AN ISO 9001:2015 COMPANY Eco-Friendly Price List w.e.f. 01/03/2018 IS : 8828 ISO 9001:2008 CERTIFIED ORGANISATION IS : 13779 Introduction Welcome to the world of BillTech, One of the reputed name in the
More informationBharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT
An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:
More informationTECHNICAL SPECIFICATIONS OF PCC PANEL
S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational
More informationPRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2015 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 380 415 440 460 480 550 600 NEMA-ABI 240 (HIC)
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationDATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT
44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7
More informationprice list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
price list THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2014 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 13 cat.a Ui690V Uimp6kV 50 60Hz
More informationTender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount
Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable
More informationIntelligent Choice for Prestigious Buildings
Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6
More informationMiniature Circuit Breaker
Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the
More informationMoulded Case Circuit Breakers
Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field
More informationPRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MAY 2018 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI
More informationMINIATURE CIRCUIT BREAKER
Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.
More informationPRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES AUGUST 2017 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 12 cat.a Ui690V Uimp6kV 50 60Hz
More informationNEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A
NEW Moulded Case Circuit Breakers New DU Series 0 A to 50 A About us Larsen & Toubro is a technology-driven USD 7 billion company that infuses engineering with imagination. The Company offers a wide range
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationMaximum Retail Price
Price List Power Distribution Components Product Name Page No. WiNmaster Air Circuit Breaker 9-0 WiNmaster ACB Order Form Air Circuit Breaker - "AH" Series 2-9 ACB Order Form - "AH" Series 20 Power Capacitor
More informationTENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID
TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID S.NO. HEAD DESCRIPTION AMOUNT (Rs.) 1 A DG SETS & ACCESSORIES
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationBHARAT HEAVY ELECTRICALS LIMITED, JHANSI
BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause
More informationBreakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary
Breakers and Switches Tmax XT Moulded-case circuit-breakers Simply extraordinary Tmax XT Simply extraordinary ABB is proud to present you the result of a long and intense research and development project:
More informationNS Feeder pillar up to 3200A
NS Feeder pillar up to 3200A Advanced technology for low voltage, outdoor distribution Merlin Gerin Modicon Telemecanique Outdoor electrical distribution with advanced technology Merlin Gerin low voltage,
More informationMAIN INCOMER -1 (500 KVA TRF.)
Sr.No. DESCRIPTION MAKE QTY 1 MAIN L.T.PANEL Design, fabrication assembling, supply, installation, testing and commissioning of cubicale type LT panels floor mounted free standing suitable for 415 V 3
More informationMaximum Retail Price
Price List Power Distribution Components Product Name Page No. Air Circuit Breaker - WiNmaster 9-0 ACB Order Form - WiNmaster Air Circuit Breaker - "AH" Series 2-9 ACB Order Form - "AH" Series 20 Power
More informationS H A D E S ELECTRICAL DB MANUFATURING
CORPORATE BROCHURE S H A D E S ELECTRICAL DB MANUFATURING S H D E S ELECTRICAL DB MANUFACTURING L.L.C. www.shadesdb.com I N T R O D U C T I O N Welcome to SHADES, this portfolio has been designed to give
More informationPerfection that Matters
Perfection that Matters Switchgear Range Catalogue 2017 Contents Power Series Distribution Boards Classique Distribution Boards Miniature Circuit Breaker Isolator Residual Current Circuit Breaker Residual
More informationTerasaki (Europe) Ltd
Terasaki (Europe) Ltd Terasaki Europe Ltd was established in 97 and is located near Glasgow, Scotland U.K. From head office at our 7,00 square metre facility, Terasaki Europe controls an International
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationMotor Protection Circuit Breakers
Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions
More informationMoulded case circuit breakers
Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded
More informationMemshield - ACB Ratings & Specifications
Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY
More informationPIX-H Metal-clad switchgear up to 17.5kV
AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...
More informationTender Schedule. Sl. No. Particulars Quantity Unit Rate `
Tender Schedule Estimate for Electrical Works at Savalyapuram Branch(18901) Guntur(District). Sl. No. Particulars Quantity Unit Rate ` 1 Wiring for light point/ fan point/ exhaust fan point/ call bell
More informationSiemens switchgear. Tried, tested, trusted. Circuit Breakers
* MP - Maximum etail Price Siemens Ltd. LV SG - Power Distribution Products MP Eff. 01-10-2014 13 MCCB: Sentron 3VT1...5 ated current - 16A to 1600A 3 and 4 pole versions Breaking capacity from 25kA to
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationAN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR
AN ISO 9001 & 14001 COMPANY TENDER DOCUMENT TENDER No: DLI/CON/696/411 FOR SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 11/0.433KV INDOOR/OUTDOOR ELECTRIC SUBSTATION AND OTHER ASSOCIATED EXTERNAL ELECTRICAL
More informationMCCB Accessories to suit AF
MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description
More informationContents. We build a better future! MCC HCB
H8PU Low Voltage We build a better future! HYUNDAI s low voltage motor control center H8PU series with a withdrawable unit are of multi-tier, factory assembled and for rated voltage of up to 660V AC. Contents
More informationEssential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.
The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.
More informationSwitches that last longer.
Switches that last longer. Switches Catalogue & List Price w.e.f. 1 st July 2017 CORPORATE OFFICE About STANDARD STANDARD is a brand of India s leading FMEG company, Havells India Ltd., that offers a wide
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationYoung energy gives you more air delivery
Young energy gives you more air delivery Fan Booklet 2015 about STANDARD STANDARD, a part of $1.4 Billion leading Fast Moving Electrical Goods (FMEG) Company, Havells India Ltd., offers a wide range of
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationQUOTING SHEET BIDDER'S PRICE % QUOTE ABOVE / AT PAR / BELOW In figures
SL. No. Tender for " CONSTRUCTION OF SUPER SPECIALITY HOSPITAL FOR GOVT. RAJAJI MEDICAL COLLEGE, MADURAI, TAMIL NADU- HT & LT ELECTRICAL INSTALLATION NIT No. - SRO/MKT/TH/325 Dated 01.11.2014 DESCRIPTION
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationAir Circuit Breakers
Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationWelcome to Corporate Presentation
Welcome to Corporate Presentation WELCOME TO SAFETY ELECTRICAL GROUP (SEG) Journey So Far. Established in September 1982. Currently have Six (6) Major Business Verticals Electrical Component (Switchgear
More informationEstimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount
Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount 1 2 Writing for light point/ fan point/ exhaust fan point /call bell point with 1.5 sq.mm FR PVC insulated
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationAIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR
AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector
More informationSection Contents. 1. Introduction 2-5. Salient features, internal & general appearance of Drawout ACB
1 Section Contents PAGES 1. Introduction 2-5 Salient features, internal & general appearance of Drawout ACB 2. Ratings & Specifications 6-9 Free air & enclosed thermal current ratings for AC & DC applications
More informationTENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR
TENDER DOCUMENT (TENDER No: ) FOR BALANCE WORK OF SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF TWO NO. 11/0.433KV INDOOR ELECTRIC SUBSTATION (ESS-1 & 2), THREE NO. OUTDOOR TYPE 11/0.433KV COMPACT SUB-STATION
More informationAir Circuit Breakers
Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationP. 07 DMX³ ACB from 630 A to 6300 A. P. 11 DMX SP 2500 ACB 630 A to 2500 A. P. 14 DRX MCCBs
MARCH Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI 240 25 (HIC) 480 7.5 600 5 DRX100B P. 07 DMX³ ACB from 630 A to 6300 A Fixed version
More informationTable Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
-1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationKENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO
BILL 1 MAINS POWER DISTRIBUTION 2-1 ITEM DESCRIPTION QTY UNIT RATE AMOUNT Supply, install, test, commission and set to work the following:- 1.01 Free-standing purpose made front access sub main switchboard
More informationSACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A
SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A Quality For You. How simple and functional can a range of moulded-case circuit-breakers be? It was answering this question, which
More informationLow Voltage Products Price list. ABB Authorised Dealer R Sanghavi Mercantile Pvt. Ltd.
With effect from st March 205 Low Voltage Products Price list ABB low voltage products ABB is a global leader in power and automation technologies that enable utility and industry customers to improve
More informationPrisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter
3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice
More informationNew DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE
New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with
More informationSwitchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable
www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder
More information3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers
.1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence
rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 21/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Construction of second floor above central block at ACES building (SH: Electrical works). Name of the
More informationBILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH
BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH SL NO. DESCRIPTION OF ITEM / WORK UNIT QTY PART - A : ELECTRICAL WORKS 1 1 Energy Meter Cubicle : a Fabrication, Supply, Installation, testing
More informationThe need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted
110 The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationPOWER DISTRIBUTION UNITS
M E M F O R M Q U A D POWER DISTRIBUTION UNITS M E M F O R M Q U A D IDEALLY SUITED TO FLEXIBLE DISTRIBUTION OUTGOING OPTIONS Memshield 2-125 G frame MCCB pan assemblies up to 18 TP outgoing ways. Memshield
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationLEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1
More informationLG Moulded Case Circuit Breakers - 3P
Model Description ka at 415V GBN103/16 100AF/16AT 3P MCCB GBN103/20 100AF/20AT 3P MCCB GBN103/25 100AF/25AT 3P MCCB GBN103/32 100AF/32AT 3P MCCB GBN103/40 100AF/40AT 3P MCCB GBN103/50 100AF/50AT 3P MCCB
More informationWest Bengal State Electricity Distribution Co. Ltd.
West Bengal State Electricity Distribution Co. Ltd. TECHNICAL SPECIFICATIONS FOR D. C. DISTRIBUTION BOARD (FOR 33 KV SUB STATIONS) Page 1 of 14 1.0 SCOPE: This specification covers the design, manufacturing,
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationManual motor starters Overview and benefits
Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More information87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS
87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084
More informationMEDIUM VOLTAGE SWITCHGEAR
MEDIUM VOLTAGE SWITCHGEAR MEDIUM VOLTAGE SWITCHGEAR Easun Reyrolle is a leader in the field of electrical power management and has more than 30 years of domain expertise in providing a wide spectrum of
More information20th Dec, aptis range
list effective 203Price 20th Dec, 203 aptis range aptis range value for money Hager unveils its "value for money" offer - aptis! A range with required features and functionality for safe electrical installations.
More informationJtec 10kA Miniature Circuit Breaker
EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in
More informationCircuit Breaker Prepared By :
Circuit Breaker Prepared By : Eng : Ayman Soliman Selmy Circuit Breaker Specification of circuit Breaker:- [1] Operating voltage of C.B [2] Rated current of C.B (Ir or In) Amp. [3] Instantaneous short
More information