1 siet Neon Transformers A world leading brand familiar to UK neon installers - now available exclusively through Sign-Tec Services. METALBOX - Patented transformers in metal cases for outdoor applications - IP44 The metal case and it s protective treatments is highly resistant to atmospheric conditions - protecting the resin filling from cracking One model for both blue gas and neon filled tubes Dimmable with leading edge dimming systems (when used with external Earth Leakage Protection devices) Available with capacitors - either on each transformer or for a group of transformers. This gives reduced power consumption - allowing up to 40% energy saving. Important when comparing with LED lighting in running costs! Provision for attaching PVC cable conduits under the lid Comprehensive technical back-up from Sign-Tec Services and Siet in Italy. Advantages of having a metal cased transformer: It protects the resin filling against atmospheric conditions It contains thermal expansion / contraction of the resin filling, which could cause dangerous cracks. It is a good conductor of heat keeping the temperature around the electric connections and the protection circuits low. It affords excellent mechanical protection. It protects against magnetic disturbances. It ensures that the case is grounded, as required by most international wiring standards. ACCESSORIES: Capacitors - giving up to 40% energy saving: Single transformers models in IP66 cases - from 6.3µF to 40µF Multiple transformer models in IP43 cases (one capacitor to correct several transformers) - from 50µF to 100µF. Protection Devices: INTERDISTOP - Combined Open Circuit & Earth Leakage Protection, complete with a terminal to connect a Remote Control system (fitted inside the transformer). PART NO DISTOP MODULAIRE - Earth Leakage Protection for multiple transformers up to 6A. Essential for dimming or flashing applications. Page 22 (v. 4) Telephone Fax enquiries@sign-tec.co.uk
2 siet Neon Transformers Simple connections for ease of installation. Conform to European standards EN61050 & EN ALL UNITS INCLUDE EARTH LEAKAGE TRIP FITTED INTERNALLY. IMPORTANT CALL THE OFFICE IF YOU INTEND TO DIM OR FLASH ONE OF THESE UNITS. METALBOX - The Top Transformer Output 18 ma Operating Current ma KV 18mA x 84 x V 18mA x 84 x V 18mA x 84 x V 18mA x 84 x V 18mA x 84 x V 18mA x 84 x V 18mA x 84 x V 18mA x 84 x V 18mA x 95 x ma Operating Current ma KV 25mA x 84 x V 25mA x 84 x V 25 ma x 84 x V 25mA x 84 x V 25mA x 84 x V 25mA x 84 x V 25mA x 84 x V 25mA x 84 x V 25mA x 95 x The 100mA types are not always available from stock - please call for delivery times. Telephone Fax enquiries@sign-tec.co.uk (v. 4) Page 23
3 siet Neon Transformers Simple connections for ease of installation. Conform to European standards EN61050 & EN ALL UNITS INCLUDE EARTH LEAKAGE TRIP FITTED INTERNALLY. IMPORTANT CALL THE OFFICE IF YOU INTEND TO DIM OR FLASH ONE OF THESE UNITS. METALBOX - The Top Transformer Output 35 ma Operating Current ma 1-2 KV 35mA x 84 x V 35mA x 84 x V 35mA x 84 x V 35mA x 84 x V 35mA x 84 x V 35mA x 84 x V 35mA x 95 x V 35mA x 95 x V 35mA x 95 x ma Operating Current ma 2000V 50mA x 84 x V 50mA x 84 x V 50mA x 84 x V 50mA x 84 x V 50mA x 95 x V 50mA x 95 x V 50mA x 95 x V 50mA x 113 x V 50mA x 113 x ma Operating Current ma 3000V 100mA x 95 x V 100mA x 95 x V 100mA x 113 x V 100mA x 113 x V 100mA x 113 x V 100mA x 113 x V 100mA x 113 x V 100mA x 140 x The 100mA types are not always available from stock - please call for delivery times. Page 24 Telephone Fax enquiries@sign-tec.co.uk (v. 4)
4 MINILEXA NEON TRANSFORMERS Core and coil reliability with electronic compactness. Indoor use Ideal for narrow spaces, small channel letters and false ceilings. Only 1.8Kg and 220 x 69 x 52mm. Terminal connections for your own lamp leads. A smart alternative to electronic converters. No Earth leakage detection fitted to these units Output Part No Current 230V 50Hz Power W IP Dimensions (mm) Weight Kg 3000V 18mA x 69 x V 18mA x 69 x V 18mA x 69 x V 25mA x 69 x V 25mA x 69 x V 50mA x 69 x V 50mA x 69 x V 100mA x 69 x COLD CATHODE BALLASTS LEXTERIOR Conventional, magnetic transformers - ideal for Cold Cathode lighting installations LOW VOLTAGE 990V - single & twin versions 50mA, 100mA & 200mA output currents IP43 Rated for Outdoor use Terminal connections for output cables siet Primary Voltage - 230/240V AC, 50 Hz Maximum Ambient Temperature - 40 C Case - Thermoplastic, resin filled Outdoor protection IP43 when installed vertically (cable entries pointing downwards) or IP40 when installed on a horizontal surface. Supplied with a fitted 2m mains cable Compatible with the best dimming controls - leading edge / forward phase control. Low Voltage Transformers Indoor / Outdoor - IP43 Rated Current (MAX) Part No Voltage Type Dimensions (mm) 25 ma 50 ma 100 ma 200 ma 62101LEX 1 x 990 Single 267 x 77 x S 1 x 990 Single 267 x 77 x S 2 x 990 Twin 267 x 77 x S 1 x 990 Single 267 x 77 x S 2 x 990 Twin 267 x 77 x x 990 Single 267 x 77 x x 990 Twin 310 x 90 x 84 Telephone Fax enquiries@sign-tec.co.uk Page 25 (v. 4)
5 hansen ELECTRONIC CONVERTORS Low Voltage Models for Cold Cathode Lighting : EVG80/1D Duo The modern neon power supply. Economical - low power consumption. Compact - can be installed within letters & boxes. Constant current output - can be used on short tubes. Built in Earth Leakage & Open Circuit protection on models over 990V. All models are white with white cables unless indicated. Models marked with a * are available in black or white. Maximum tube lengths for 990V low voltage EVGs (measured from electrode shell to electrode shell) Diam. 10 mm Blue filled - Outdoors 12 mm 15 mm 18 mm 20 mm 1 tube tubes Blue filled - Indoors 1 tube tubes Dimming of Hansen converters - The chart at the bottom of this page includes all dimmable by mains type converters. These can be dimmed using a trailing edge, (or reverse phase) dimming device, such as our large scale TR5 or TR10 units on page 32. Alternatively we have a new low cost but low current device which can run up to 3 units of the dimmable range. This is supplied in a wall switch type format and can also be operated with remote control please call the office for further detail. Quantity Discounts : = 4% / = 6% / = 10% / 50+ = please call for best prices EVG 20/1 Slim Line * 20mA 990V 0.20A 160x29x EVG 40/1 Slim Line 40mA 990V 0.25A 160x29x EVG 40/1 DuoCAB 2 x 40mA 990V 0.45A 186x45x EVG 50/1 50mA 990V 0.35A 160x40x EVG 60/1 60mA 990V 0.40A 160x40x EVG 80/1 80mA 990V 0.50A 170x53x * Available in White or black Dimmable by mains control (available with mains or Plug&Play mains leads - Ask for options) EVG 40/1D 40mA 990V 0.27A 205x39x EVG 40/1D Duo 2 x 40mA 990V 0.50A 205x49x EVG 80/1D 80mA 990V 0.50A 207x39x EVG 80/1D P&P 80mA 990V 0.50A 207x39x m P&P 2.0 EVG 80/1D IP65 P&P 80mA 990V 0.50A 207x39x m P&P 2.0 EVG 80/1D Duo 2 x 80mA 990V 0.80A 207x49x EVG 80/1D Duo P&P 2 x 80mA 990V 0.80A 207x49x29 2.5m P&P 2 EVG 80/1D Duo IP65 P&P 2 x 80mA 990V 0.80A 207x49x29 2.5m P&P 2 EVG 120/1D 120mA 990V 0.40A 207x52x EVG 150/1D SPECIAL ORDER 150mA 990V 0.50A 207x52x Dimmable by 0-10V control EVG 120/1D 0-10V 120mA 990V 0.40A 207x52x Page 26 (v. 4) Telephone Fax enquiries@sign-tec.co.uk
6 hansen The modern neon power supply Economical - low power consumption Compact - can be installed within letters & boxes Constant current output - can be used on short tubes Integral Earth Leakage & Open Circuit protection where required New models for dimming applications! Key : ELECTRONIC CONVERTORS Types marked D have a built in dimming adjustment; The D (central) units are dimmable by control voltage (0-10V control devices supplied separately); Duo units have two sets of outputs, to connect two tubes of similar lengths - both at low voltage. = for Blue Gas; = for Neon Gas ONLY! = for either Blue or Neon Gas Standard colour - white, Items with * are available in white or black Quantity Discounts : = 4% / = 6% / = 10% / 50+ = please call for best prices High Voltage Standard Models : * White or black EVG 20/2 SL 20mA 2000V 0.25A 160x29x EVG 20/2R SL 20mA 2000V 0.25A 160x29x EVG 20/3 20mA 3000V 0.35A 160x40x EVG 20/4 20mA 4000V 0.50A 170x53x EVG 20/5D * 20mA 5000V 0.55A 198x33x35 x EVG 20/8D * 20mA 8000V 0.95A 205x50x46 x EVG 30/2 30mA 2000V 0.40A 160x40x EVG 30/4 30mA 4000V 0.60A 170x53x EVG 40/3 40mA 3000V 0.60A 170x53x EVG 50/2.5 50mA 2500V 0.60A 170x53x EVG 50/4 50mA 4000V 0.55A 255x55x EVG 60/2 60mA 2000V 0.60A 170x53x EVG 80/1.5 80mA 1500V 0.60A 170x53x Special Models : EVGs Dimmable by Control Voltage Dimmable by control voltage - in addition to a mains cable, each converter has a 2-pole connection cable (5mm dia.) that accepts a 0-10V control voltage, which can produce an infinitely variable tube current. Can be specified as either 10V = full power, or 0V = full power. EVG 40/3D 40mA 3000V 0.60A 260x62x EVG 50/2D 50mA 2000V 0.60A 260x62x V dc Dimmer Supplies a 0-10V DC voltage for control of suitable EVG and LED products 9EVGCTRL-S Flashing EVGs (suitable for indoor installations) FLASH SPEED CONTROL ON 20/5 AND 20/8 ONLY (0.4-5 Seconds) EVG 20/3 Flasher 20mA 3000V 0.35A 160x40x35 x EVG 20/5 Flasher 20mA 5000V 0.55A 210x39x37 x EVG 20/8 Flasher 20mA 8000V 0.95A 230x58x46 x Telephone Fax enquiries@sign-tec.co.uk Page 27 (v. 4)
7 Installation Advice (see for more): Installation of the high-voltage cables Avoid accumulation of heat Wrong: - long distance between convertor and neon tubing! Wrong: - high-voltage cables installed parallel in Correct: - high-voltage cables installed at a shorter distance to the neon tubing! An accumulation of heat must be avoided by all means during installation. The distance between the convertors should therefore be at least 2 cm. Avoid additional heat by direct sunlight! The EVGs can be mounted directly on metal surfaces without any restrictions! Maintain clearance at high voltage Special advice for 5 and 8 kv convertors: When connecting long tubes, make sure that the tubes do not touch each other (Caution: high voltage sparkover)! It is always recommended to use protective end caps (silicone)! The cable must be installed at a distance from the other electrode connection! Observe maximum connectable tube length maximum tube length Correct: The maximum tube length is not exceeded. maximum tube length Wrong: The maximum value given in the tube length table has been exceeded! Do not connect more than one neon letter Correct: Connect only the tubes of one letter to the EVG! Wrong: Never combine the tubes of several letters! For 5 kv and 8 kv convertors Due to the high secondary voltage and the integrated open circuit protection, the 5 kv and 8 kv convertors are not suitable for outdoor installations! FLASHERS for NEON & LED convertors : Hansen s own flashers specifically designed to work with Hansen neon and LED convertors. Compatible models are: For neon: 20/1SL - 40/1SL - 40/1.5-50/1-60/1-80/1-80/1.5-20/2-20/3-30/2-50/2.5-60/2-40/3-20/4 & 30/4 and for LEDs: c25/990 & c40/650 2 Way Flasher 8 Programs 3 Way Flasher 14 Programs 6 Way Flasher 14 Programs 2 x 240V 50Hz - max 2A per channel 3 x 240V 50Hz - max 1A per channel 6 x 240V 50Hz - max 1A per channel 240V 50Hz 80x80x40 9EVGFL2 240V 50Hz 155x100x42 9EVGFL3 240V 50Hz 155x100x42 9EVGFL6 Special Program charge Special Programs to your own specification (charged once for multiple units with the same program) ALL ARE STEP TIME ADJUSTABLE FROM SECONDS PER STEP Page 28 Telephone Fax enquiries@sign-tec.co.uk (v. 4)
8 SILICONE ELECTRODE COVERS Moulded from non-inflammable, high tear silicone rubber, conforming to EN High resistance to UV radiation and ozone. Breakdown voltage : 15 kv Wall thickness : 1.5mm Operating temp : 210 C Hardness : 50 shore A Online catalogue at Straight Through Design Return Design AVAILABLE IN NATURAL (CLEAR), SOLID WHITE & BLACK Quantity discounts are available - 5% for and 10% for The net prices are shown below. The quantity can be made up from any combination of sizes & types. Straight Through Design Return Design 10mm dia.x 45mm Natural 9FB0N % 10mm dia. x 45mm White 9FB0W % 10mm dia. x 45mm Black 9FB0B % 13mm dia.x 45mm Natural 9FB % 13mm dia. x 45mm White 9FB1W % 13mm dia. x 45mm Black 9FB % 16mm dia.x 65mm Natural 9FB % 16mm dia. x 65mm White 9FB3W % 16mm dia. x 65mm Black 9FB % 18mm dia.x 65mm Natural 9FB % 18mm dia. x 65mm White 9FB5W % 18mm dia. x 65mm Black 9FB % 10mm dia.x 45mm Natural 9FBG % 10mm dia. x 45mm White 9FBH % 10mm dia. x 45mm Black 9FBJ % 13mm dia.x 45mm Natural 9FBA % 13mm dia. x 45mm White 9FBAW % 13mm dia. x 45mm Black 9FBB % 16mm dia.x 65mm Natural 9FBC % 16mm dia. x 65mm White 9FBCW % 16mm dia. x 65mm Black 9FBD % 18mm dia.x 65mm Natural 9FBE % 18mm dia. x 65mm White 9FBEW % 18mm dia. x 65mm Black 9FBF % SILICONE BUSHES Natural silicone rubber bushes for protecting glass or cables when passing through panels. For 18mm holes, o/d 37mm, centre hole 17mm dia. For 22mm holes, 0/d 42mm, centre hole 20mm dia. 3FB1 3FB2 Telephone Fax enquiries@sign-tec.co.uk Page 29 (v. 4)
9 ELECTRODE HOUSINGS Glass housings made from heat resistant glass, approved by US Underwriters Labs. to 7.5kV. Spring contact inside. No. 200, for 16mm electrodes, 1.25 x No. 200P, for 16mm electrodes, 1.25 x No. 100, for 18mm electrodes, 1.75 x TUBE SUPPORTS Plexiglas : Clear hollow polycarbonate pillar, with countersunk recess for screw fixing - takes a 4mm screw. Tube rests on dished top and is wired through holes in the pillar. Quantity discounts : = -5% = -10% (any combination of sizes) 10mm high 20mm high 30mm high 40mm high 50mm high 60mm high 70mm high 9FP1 9FP2 9FP3 9FP4 9FP5 9FP6 9FP7 Neon Plus : Clear polycarbonate tube support with rotating head and extension screw. Quantity discounts : = -5% = -10% (any combination of sizes) 20mm high 40mm high 60mm high Extension 9FNP2 9FNP4 9FNP6 9FNPE Clear Plastic : Coarse threaded stem with integral head, separate foot. Can be cut down to 30mm minimum. 70mm high 9FCP Self Tapping : White T shaped moulded nylon body with a moulded in self tapping screw 3x13mm. 25mm high 35mm high 50mm high 9ST2 9ST3 9ST5 Porcelain Supports & Brass Studs : Traditional porcelain heads, for use with brass studs and nuts. Large Heads, 4BA thread, 26mm wide Brass Studs, 1.5 4BA 0522 Brass Studs, 2.5 4BA 0524 Brass Nuts, 4BA 0523 Page 30 Telephone Fax enquiries@sign-tec.co.uk (v. 4)
10 TUBE SUPPORTS Crocodile Head - Clear Plastic : Adjustable head for small diameters with separate foot. Stem can be cut down to 25mm minimum mm high 9FCR Clip On Polycarbonate Supports : Quantity Discounts on this page: % % 09mm dia. / 42mm high 09mm dia. / 42mm high 10mm dia. / 22mm high 10mm dia. / 32mm high 10mm dia. / 42mm high 10mm dia. / 52mm high 12mm dia. / 22mm high 12mm dia. / 32mm high 12mm dia. / 42mm high 12mm dia. / 52mm high 12mm dia. / 62mm high 15mm dia. / 22mm high 15mm dia. / 32mm high 15mm dia. / 42mm high 15mm dia. / 52mm high 15mm dia. / 62mm high 18mm dia. / 32mm high 18mm dia. / 42mm high 18mm dia. / 52mm high 18mm dia. / 62mm high 20mm dia. / 32mm high 20mm dia. / 42mm high 20mm dia. / 62mm high 20mm dia. / 72mm high 9FGR FGR09-42blk 9FGR FGR FGR10-42 (+Black) 9FGR FGR FGR FGR12-42 (+Black) 9FGR FGR FGR FGR FGR15-42 (+Black) 9FGR FGR FGR FGR1842 9FGR FGR FGR FGR FGR FGR20-72 Universal - to use with Cable Ties or Nickel Wire : Clear polycarbonate with a spring loaded head with a slot to take a 3mm cable tie or holes for Nickel wire. Integral foot for screw fixing mm high 9FGU mm high 9FGU mm high 9FGU mm high 9FGU mm high 9FGU mm high 9FGU80 Nylon ties, 100mm 9FGUTie PLEASE NOTE IF YOUR INSTALLATION IS HARD TO GET AT/SERVICE OR IS CRITICAL, ENSURE THAT YOU USE THE NICKEL WIRE METHOD. CABLE TIES ARE GENERALLY INTENDED FOR USE IN NON CRITICAL SITUATIONS. (v. 4) Telephone Fax enquiries@sign-tec.co.uk Page 31
11 H.T. CABLES White Double Insulated LSF, 3.2mm dia., 2KV White Double Insulated LSF, 3.2mm dia., 2KV Transparent PVC, Type NYL, 6.5mm dia., 5KV / 10 KV, EN50107 Type G Translucent Silicone (milky appearance), 6.5mm dia., 5KV / 10 KV, EN50107 Type B White Silicone Rubber, 6.5mmdia., 5KV / 10KV, EN50107 Type B Black Silicone Rubber, 6.5mmdia., 5KV / 10KV, EN50107 Type B White Silicone Rubber with PVC sheath, 8.5mm dia., 5KV / 10KV, EN50107 Type C Black Silicone Rubber with PVC sheath, 8.5mm dia., 5KV / 10KV, EN50107 Type C White, Silicone Rubber with metal braid and PVC sheath, 10mm dia., 5KV / 10KV, EN50107 Type D m m Installation requirements for cables conforming to EN50143 / EN50107: Cable Type B C D G CABLE CLIPS Within protective enclosures Type of installation In all situations other than recessed within materials Recessed within materials Self Adhesive metal tongue cable clips, up to 4mm diameter Self Adhesive metal tongue cable clips, up to 8mm diameter FIXING ACCESSORIES 056CL1 056CL2 Nickel Wire, 0.5mm dia., reels of approx. 100gm metres 0521 Waterproof Compound, Henley s Green, new BS formula 0565 Fireman s Switch, 25 Amp, Red, 3 phase and neutral 0551N Tube Tester, battery operated 0M80 NEON MILLIAMMETER For measuring the current in cold cathode & neon lamp circuits - essential for correct calibration of transformers. Gives true RMS readings on both conventional transformers and High Frequency units up to 50kHz. Simple to use. Size : 125 x 74 x 27mm, supplied in a soft case Measuring range : 3-200mA Accuracy : +/- 1%, 3 digits, true RMS reading. No battery required. Part No 9M50 Page 32 Telephone Fax enquiries@sign-tec.co.uk (v. 4)
12 DIMMERS & CONTROLLERS Manual Dimmers : Wide range of capacities available Some self contained, others for wiring to external controls The RV & numbered Models are for non-power factor corrected transformers, fluorescent lamps or incandescent lamps. The TR models are for trailing edge dimmers suitable for electronic transformers. We can also supply different 0-10V control units and dimming systems - please call to discuss your requirements. Below is a selection of the dimmer models available : 446 RV5 6A with ROTARY CONTROL mounted on a water tight box (no remote control possible) IP55 4-5A, with rotary control knob to be mounted separately. Can be slaved together in multiples. Can be used with 0-10V control systems. 150x86x x90x RV A Version of the above 144x102x RV A version of the above (sold less rotary knob) 144x102x TR5 Rotary potentiometer knob to use with RV and TR dimmers, supplied with fittings for panel mounting. **For Electronic Transformers.** 4-5A, with rotary control knob to be mounted separately. Can be slaved together in multiples. Can be used with 0-10V control systems. 22mm dia., 40mm max depth x102x56 TR A version of the above 144x102x56 960D Larger sizes of dimmers are available to order, from 12 Amps to 50 Amps. Please call for details. 960C DMX Dimmer Pack - RGB Neon: Ultimate automated effects with up to 512 channel DMX technology. 4 circuits of 1000W each, which can be used as a dimmer or chaser. Option to use manually with a remote control and memory function. Can be interlinked for larger installations. Leading edge dimming for magnetic, non-power factor corrected transformers etc. Box 45-4x1000W HF3014 Remote control 960B45 960HF From Siet - Dimmers and controls: Leading edge dimmers specifically designed to operate conventional magnetic neon transformers, as well as other loads. Controlled either by a locally mounted potentiometer or by 0-10Vdc control signal. Can be used in conjunction with various timers and programmable controllers, light and motion sensitive controls as well as DMX and DALI interfaces - enabling the installation to work with sophisticated lighting systems. Type Dimmerbox - 15 Amp Remote control with receiver Universal wall mounting dimmer pot. Regulator with 2 potentiometers Timer - 2 channels Junior Manager - motion & ambient light level sensor (0-10V output) DALI Interface - to link Dimmerboxes to DALI systems Other controls, such as movement sensors and programmable units are available. Please ask for details. (v. 4) Telephone Fax enquiries@sign-tec.co.uk Page 33
13 ELECTRONIC FLASHERS Please note that special requirements may be necessary when using these products with transformers requiring Earth Leakage Protection. Please call for more advice. OTHER TYPES ARE AVAILABLE - PLEASE CALL FOR FULL DETAILS! Integrated Flashers : Low cost. For use inside signs ABS watertight case IP643 Inputs & outputs by bonded in cables Choose either Slow (1 sec./1 sec.) or Fast (0.5 sec./0.5 sec.) fixed speed 3 Year warranty 489L & 489R 416L & 416R 1 x 1.5A, L=slow R=fast 1 x 2.5A, L=slow R=fast 100x35x & x50x & 9614 Promo 2000 Series Flashers : ABS Watertight box IP555 Cable entries by cable glands Adjustable speed 0.1sec. to 1.5sec. per step Zero cross over system Outputs for any type of load 5 year warranty x 6A, On/Off 150x86x x 6A, Alternating 150x86x x 6A, On/Off with Full On switch connection 1 x 12A, On/Off with Full On switch connection 2 x 6A, On/Off with Full On switch connection 2 x 12A, Alternating with Full On switch connection 150x86x x86x x86x x175x Promo 2016 Series Flasher : 16 selectable programs for 3 & 4 channels ABS Watertight box IP555 Cable entries by cable glands Adjustable speed 80msec. to 1.5sec. per step Zero cross over system Outputs for any type of load 5 year warranty or 4 x 2A 150x86x Page 34 Telephone Fax enquiries@sign-tec.co.uk (v. 4)
14 Promo 4200 & 6000 Series Flashers : 64 selectable programs for 4, 5 or 6 channels ABS Watertight box IP555 Cable entries by cable glands Adjustable speed 80msec. to 1.5sec. per step HBC fuse protection for each channel Zero cross over system Outputs for any type of load 5 year warranty Full On switch connections or 4 x 6A 250x175x or 6 x 6A 300x190x Promo 2000, 4200E & 6200E Series Flashers with Built In Earth Leakage Protection : EN50107 compliance when used with neon transformers with e terminals Other specifications as per Promo 2000, 4200 & 6200 models In the event of an earth fault with one of the transformers, the built in earth leakage trip switches off the supply to the flasher. 5 year warranty x 6A, On/Off 150x86x x 6A, Alternating 150x86x x 6A, 64 programs 300x190x x 6A, 64 programs 300x190x Earth Leakage Protection Switches : EN50107 compliance when used with neon transformers with e terminals In the event of an earth fault with one of the transformers, the earth leakage trip switches off the supply to the transformer. Use with flashers, dimmers and for updating old signs. 3 year warranty 440 6A - 2 x e connections 100x35x31 96ELS6A A - 4 x e connections, IP55 150x86x58 96ELS25A Promo 2006 & 4006 Programmer + Dimmers : Multi-program flashers with built in dimmers, which allow the lighting limits to be adjusted, together with cross fade & other automated dimming effects 16 programs, Adjustable speed, Adjustable dimmer level. These products should not be used with transformers with integrated Earth Leakage Protection. Please call for more advice. 5 year warranty x 6A 177x175x ** x 6A 177x175x ** = Includes flicker program OTHER TYPES ARE AVAILABLE - FULL DETAILS ON REQUEST! (v. 4) Telephone Fax enquiries@sign-tec.co.uk Page 35
15 LOW VOLTAGE LED FLASHERS & DIMMERS Promo LED Technology Easy to install - connect in between a single LED power supply (between 8V and 24V DC) and give controlled outputs to the LEDS, meaning that the installation is 100% low voltage. They all have adjustable speed control. The Programmed Dimmers have level adjustments as well. Most units include protection against reverse polarity connection and short circuits. All backed up by the usual Promo 5 year warranty, except for the DC12-24 and Box 36 with 1 year warranty. All models accept between 8V and 24V DC supply. Housings are IP55. LED Flashers x 6A, Alternating Flasher 150x86x58 96L x 12A, Alternating Flasher 150x86x58 96L / 4 x 5A, 64 programs Flasher 177x175x90 96L / 6 x 3A, 64 programs Flasher 177x175x90 96L62 LED Dimmers - PWM technology, 0 to 100% dimming x 5A, Programmed Dimmer - RGB, 10 dimmed programs 177x175x90 96L x 5A, Dimmer - manual or auto fading 150x86x58 96L10 Scarlett - A Hansen controller for Neon and LED products The multi purpose flexible controller. SD card memory, simple programming. Output possibilities are - PWM 0-10 volt Relay RGB. DMX Can be slaved together to give many possibilities Hansen Remote controller Page 36 Telephone Fax enquiries@sign-tec.co.uk (v. 4)
LIGHTING COMPONENTS. CATALOGUE & PARTS LIST 2019 online at New LED catalogues available. All items correct at date of print.
LIGHTING COMPONENTS CATALOGUE & PARTS LIST 2019 online at www.sign-tec.co.uk New LED catalogues available Contents : Page 2-4. Page 5. Page 6. Page 7. Page 7-8. Page 9-12. Page 13 Page 14-17 Page 18 Page
More informationTransformers for Low-voltage Halogen Incandescent Lamps
Transformers for Low-voltage Halogen Incandescent Lamps Independent electronic converters 10 14 With DLI interface 14 Electronic built-in converters 15 17 Potentiometer and dimmers 18 Electromagnetic safety
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationInstallation & User Instructions
Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.
More informationMANUFACTURED IN THE UK
The Galileo II range of decorative, wall or ceiling mounted luminaires, are as versatile as they are attractive. The range is available in two body sizes, 350mm and 425mm diameter, and in a variety of
More informationicebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44
Icebreaker is an ultra slim 2D luminaire at home in many IP44 applications. Ideally suited for bathrooms and utility areas, and most widely preferred in social and key worker housing and student accomodation.
More informationINSIGHT WHAT ARE YOU LOOKING FOR IN LED LIGHTING?
MAY 2018 ISSUE INSIGHT WHAT ARE YOU LOOKING FOR IN LED LIGHTING? EXPERTISE, RELIABILITY, SUPPORT & FREE NEXT DAY DELIVERY s VALUE? Everyday Economy Lighting Competitive commercial offer Suitable for everyday
More informationMK Electric IP Solutions
MK Electric IP Solutions Masterseal Plus MK Shield IP56 MK Splashguard IP55 Thrives in the Toughest Conditions. MK Electric IP Solutions wiring devices ingress protected www.mkelectric.co.uk MK Electric
More informationUnderfloor to desk 231
Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationACCESSORIES ACCESSORIES CCESSORIES A 312. DIMMERS 315. SENSORS 318. CONNECTORS 320. SADDLES 321. SURFACE SOCKETS 322. BATTEN FIXTURE 322.
ACCESSORIES 312. DIMMERS 315. SENSORS 318. CONNECTORS 320. SADDLES 321. SURFACE SOCKETS 322. BATTEN FIXTURE 322. POWER BOARDS 323. EXTENSION LEAD 324. FLEX & PLUGS 325. LAMP HOLDERS 326. STARTERS 311 Push
More informationDoc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No
The Galileo II range of decorative, wall or ceiling mounted luminaires, are as versatile as they are attractive. The range is available in two body sizes, 350mm and 425mm diameter, and in a variety of
More informationDoc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No
Icebreaker is an ultra slim 2D luminaire at home in many IP44 applications. Ideally suited for bathrooms and utility areas, and most widely preferred in social and key worker housing and student accomodation.
More informationSafety Lampholders and Pendants
Safety Lampholders and Pendants Safety products are designed to make life easy for you. When the lamp is removed from the lamp holder body the power is automatically disconnected at the contacts - ensuring
More informationTraining & Didactic Systems. Fundamentals of Electrical Engineering
Training & Didactic Systems Fundamentals of Electrical Engineering Catalog WA1E/01 Table of Contents Page Our Service, Our Customers and fields of technology 2 Introduction 4 Instruction modules measuring
More informationLED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2
LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL LED FlatPanel Gen. 2 LED Recessed Mounted FlatPanels The use of state-of-the-art LED technology in conventional office and hall illumination provides a lot of
More informationJBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER
JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality
More informationEmergency lighting units EM series
EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface
More informationRE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW
Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No
More informationTel: &
C O N T R O L S BRITISH QUALITY COMPANY Split Core Current Transformers & Transducers Primary Currents from 50 to 5000 Amps Accuracy Class 1 & Class 0.5 1 Amp & 5 Amp Secondaries 0-333mV AC Transducer
More informationOUTDOOR TRACK. LABELS Assembled in America
OUTDOOR TRACK DESIGNED BY GREGORY KAY PATENT-PENDING FEATURES & BENEFITS Offers the flexibility of 2-Circuit Track Lighting in an exterior environment Uses 12VAC low voltage wiring without the need for
More informationDALI 650mA LED Driver
Installation Guide DGLC650C18DD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095
More informationTechnical Data. Dimmer Switches - Push Type 881P/885P 882P 883P 884P
Technical Data Brief product description: The subtle design will blend with any décor - suitable for domestic or commercial installations. Features: Stylish modern profile Covers to conceal fixing screws
More informationGP Dimming Panels 230 Volt (CE)
GAFIK Systems 30 Volt (CE) gp- 03.0.04 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim.
More informationMANUFACTURED IN THE UK
The Trojan range of energy efficient bulkhead fittings are manufactured with a polycarbonate base and diffuser. Together with a poured gasket the Trojan leads vandal-resistant IP65 technology. With a hinged
More information3 TM Cold Applied Barrier Boot System
M Technical Information : Barrier Boot TM Cold Applied Barrier Boot System For rated voltages 6.5/11(12) kv and 8.7/15(17.5) kv 92-EE 717-1 Product Description The Cold Applied Barrier Boot System consist
More informationOEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose
OEM Emergency Portfolio Product Guide Emergency components for LED, fluorescent and auxiliary purpose Contents Introduction to this guide 3 LED Modules 4 PHL-EL3 PHL-EL3-80 PHL-EL3-D PHL-EL3-D80 PHL-EL3-4
More informationKV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: High Voltage AC Test Set KV3-250 mk2 KV4-300 mk2 KV5-100 mk2 KV5-100T mk2 KV5-200 mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge
More informationMetrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.
Metrohm Martindale Electric Metrohm House, Imperial Park, Imperial Way, Watford, Hertfordshire, WD24 4PP, UK T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk
More informationGP Dimming Panels 230 Volt (CE)
30 Volt (CE).3.08 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim. Models available with:
More informationGP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL
rev gp-a 7.0.00 GP3/4 Mini Panels GP8-4 Standard-Size Panels DESCRIPTION Provide power and dimming for up to 44 load circuits. Control any light source, including full-conduction non-dim. Models available
More informationTender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount
Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable
More informationLED DOWNLIGHTS. Pro and Prime LED Downlights ADVANTAGES OF VS LED DOWNLIGHTS
LED DOWNLIGHTS ADVANTAGES OF VS LED DOWNLIGHTS LED Recessed Mounted Downlight and DecoLEDs The integration of solid state lighting technology into conventional down lights provides optimal light distribution
More informationElectromagnetic Flow Monitor magphant
Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationCompact System NRGS 11-2 NRGS Original Installation Instructions English
Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive
More informationDoc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No
The Micro-Max is the smaller version of the Mini-Max, retaining the market leading features of the larger model. A prismatic diffuser gives an even light distribution from the energy efficient 2D lamp.
More informationADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com
ADVANCED GUIDE TO LED LIGHTS & DRIVERS astrolighting.com CONTENTS 1 DRIVERS 1.1 Do I need a driver? 1.2 How do I know what driver to use? 2 SPECIFICATION 2.1 Constant current rating 2.2 Forward voltage
More informationTechnical information
H) Twin wiring h.p.f.c. in parallel I) Single wiring l.p.f. with internal starter P) Wiring in series l.p.f., external starter Q) Wiring in series h.p.f.c. in parallel, external starter Electronic transformers
More information2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years
2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years The Trojan range of energy efficient bulkhead fittings are manufactured with a polycarbonate
More informationADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com
ADVANCED GUIDE TO LED LIGHTS & DRIVERS astrolighting.com DRIVERS DO I NEED A DRIVER? Only products with integrated LED require drivers If your integrated LED light is marked or specified as Class III,
More informationPRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY
Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy
More informationPack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way
white 7300 00 7300 02 7300 07 7301 07 7301 33 7300 06 7300 08 7300 09 Terminal screws captive and backed off ready for cabling Surface mounting boxes (see p. 112) Pack Cat. os. Single pole plate switches
More informationUser Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring
User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3
More informationGrosvenor Plus 138 decorative Solid brass highly polished, with rope-edge detail Pre-treated heat-cured powder lacquer finish Total safety
38 Grosvenor Plus wiring devices decorative www.mkelectric.co.uk range introduction feature benefits Grosvenor Plus stylish solid brass and elegant rope-edge detail combine in an extensive range exclusively
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More informationIP44 - IP66 Rated RCD, Power & Cable Management
IP44 - IP66 Rated RCD, Power & Cable Management IP54 Rated 10 amp Switches IP66 Rated 10 amp Switches IP66 Rated 13 amp Sockets IP66 13 amp RCD switched Socket IP66 13 amp unswitched socket with timer
More informationINSTALLATION MANUAL FSS1 HIGH SECURITY DOOR MONITORING SENSOR
INSTALLATION MANUAL 1. INTRODUCTION The FSS1 is a patented device designed to provide a high security door position monitoring solution. It is the ideal higher security replacement for traditional balanced
More informationEST Electrical Service Technician Answer Schedule
EST 2075 - Electrical Service Technician Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the accepted answers to the examination questions. A
More informationAbbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL
Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL DESCRIPTION. The Model BD-50E is a rugged tester designed for testing tank lining and other applications where extended use is necessary.
More information650mA Phase Dimmable LED Driver
Installation Guide DGLC650C18PD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More informationLow and High Voltage Power Supplies
Low and High Voltage Power Supplies We work according to ISO 9001: 2008 Since 1994 Fug works according to the quality assurance system ISO 9001. All shipped units are checked and documented in our testing
More information( )
(1-800-492-8826) OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels
More information(770)
(770) 345-0010 OVERVIEW Convenient and ready-to-connect, WATTCO control panels include temperature, power, multi-loop, process, and safety limit controllers. Designed for electric heaters, control panels
More informationTOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)
TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29499-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the user
More informationPIL0478 ISSUE 01/ 07/16
ISSUE 01/ 07/16 PIL0478 ZAFIR G9 CEILING FITTING PIL0478 ISSUE 01/ 07/16 PART C PART E PART 21 SELV 1 1.B 1 3.1 3.3 3.4 3.5 3.6, 3.8 3.10 3.12 3.14 3.16 3.17 3.18 3.19 3.19 ATTENTION! THE TABLE BELOW
More informationAdjustable Pneumatic Time Delay Switch
Adjustable Pneumatic Time Delay Switch Model: DS4 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.
More information1000mA - 650mA Phase Dimmable LED Driver
Installation Guide DGLC1000C25PD 1000mA - 650mA Phase Dimmable LED Driver PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU
More informationEmergency lighting units EM series. EM PRO EZ-3, V PRO version
T T TC-DE TC-SE TC-TE TC-F TC- TC-DD Tc EM, 0 40 V PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent lamps
More informationFree Fall Fire Valve Range & Accessories
Free Fall Fire Valve Range & Accessories 1 Contents Screwed Free Fall Fire Valves... 3 Flanged Free Fall Fire Valves... 6 Free Fall Valve Accessories... 8 Fitting Kits... 8 Mercury and Non-Mercury Switches...
More informationNew dimming drivers are compatible with most wall dimmers for % light control. For non-dimming
CONSTANT VOLTAGE POWER SUPPLIES CONSTANT VOLTAGE New dimming drivers are compatible with most wall dimmers for 10-100% light control. For non-dimming applications or for use with AL-PWM-6A, use LED-DR
More informationLP Dimming Panels. GRAFIK Systems
GAFIK Systems lp-1 12.8.03 are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Work directly with incandescent, magnetic low voltage,
More informationElectromagnetic Flow Monitor magphant
Technical Information TI 036D/24/ae Electromagnetic Flow Monitor magphant Flow monitoring in 1 to 80 pipes with conductive liquids Monitoring and measurement Flow monitoring with selectable limit values
More informationWorld Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants
World Class Power Solutions Rectifiers For Stationary Battery Systems in Nuclear Power Plants General 2 1.1 Application Electronically controlled rectifier assemblies are used in conjunction with suitable
More information& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL
72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com
More information1.Safe testing IMPORTANT:
Electricity is dangerous and can cause injury and death. Always treat it with the greatest of respect and care. If you are not quite sure how to proceed, then stop, take advice from a qualified person.
More informationΑΥΤΟΜΑΤΗ ΣΤΡΑΤΣΩΝΑ ΕΛΕΓΚΤΕΣ
ΑΥΤΟΜΑΤΗ ΣΤΡΑΤΣΩΝΑ ΕΛΕΓΚΤΕΣ TI-P403-52 / 4033xxB 1/5 AB Issue 3 and Blowdown Controllers Compact unit for TDS control on large or small boilers. Wall or panel mounted versions. 4 digit LED display (ppm
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationDycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More informationLED Wall Sconce. Offered with a frosted lens, these wall luminaires provide a high quality diffuse light due to their high CRI of more than 90.
Luminaires - LED Wall Sconce 04 LED Wall Sconce STANDARD offers two different styles of LED Wall Sconces, one of traditional design and the other more modern with a linear profile. These two models can
More informationPANELS STRIPS LAMPS DOWNLIGHTS DRIVERS
LED LIGHTING PANELS STRIPS LAMPS DOWNLIGHTS DRIVERS w w w. i n t e g r a l - L E D. c o m LED Downlights Push and lock design to provide an easy-fit installation Chip-on-board LED by Sharp High quality
More informationSynergy WIRING ACCESSORIES / PRODUCT GUIDE
form and function in perfect harmony WIRING ACCESSORIES / PRODUCT GUIDE Contents The philosophy 04 Packed with features 06 True functionality 08 The range at a glance 10 Synergy function selection chart
More informationSNL Glass Housings & Accessories
Glass Insulators Allanson s Glass Insulators are manufactured from the finest made heat resistant glass; all of our glass housings include a cadmium plated steel ferrule. The # Housing (#HO-) Made to withstand
More informationFLUORESCENT INDUCTION
FLUORESCENT INDUCTION Electrodeless Lamp OPENING NEW FRONTIERS FOR LIGHTING IT IS IMPOSSIBLE TO IMAGINE MODERN LIFE WITHOUT ELECTRIC LIGHTING. WITH THE WIDE AVAILABILITY AND AFFORDABILITY OF TODAY S LIGHTING,
More informationLS Series Limit Switches. Short Form Catalogue AC1300 ABB
Short Form Catalogue LS Series Limit Switches AC ABB LS Series Limit Switches Foot Switches Contents Panorama... 2 Limit Switches - Plastic Casing and Metal Casing... 12 Safety Limit Switches - Plastic
More informationMARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions
4.4 Storage Conditions The FD650/R and FD500/T or FD600/T should be kept in warm dry conditions away from direct sources of heat or sunlight, with the battery removed and in such a manner as to preserve
More informationNew DX 3 High rating & breaking capacity
New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand
More informationFrost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor
Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient
More informationLED DOWNLIGHTS. Prime K L LED Downlights with Separate LED Driver HIGH QUALITY COB TECHNOLOGY LED DOWNLIGHTS WITH SEPARATE LED DRIVER
LED DOWNLIGHTS HIGH QUALITY COB TECHNOLOGY LED DOWNLIGHTS WITH SEPARATE LED DRIVER LED Recessed Mounted Downlight Use of modern LED technology in conventional downlight applications provides an optimal
More informationDoc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No
Clean design lines give the Meridian range a leading edge for internal, easily maintained fittings. A straightforward design with a twist and lock diffuser means user-friendly maintenance and cost savings
More information1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED
Art. no.: 1711DE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please
More informationElectrical Accessories
288 282 272 Looking for the classic porcelain lampholder? A hard-to-find household adapter? Or a wide range of replacement appliance switches? You ll find them in our accessory line along with quality
More informationA.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual
Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323
More information1 Phase electronic contactor (SC 1)
1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or
More informationPHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:
PHASE CONVERTERS MODEL NO: PC40 and PC60 MODEL PART No: NO: 6012805 PC20 and PC40 6012810 PC60 PART Nos: 6012800 6012805 6012810 OPERATING & MAINTENANCE INSTRUCTIONS 0107 Specifications PC20 PC40 PC60
More informationTemperature Controllers
Controllers SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device,
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationFLOODLIGHTS FASTLED DATASHEET
FLOODLIGHTS FASTLED DATASHEET floodlights High-efficiency LED floodlight. Available with colour temperatures 3000 K-4000 K-6000 K RGB (only in the 36-LED version) Equipped with secondary optical beams:
More informationTECHNICAL SPECIFICATIONS OF PCC PANEL
S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational
More informationCABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.
CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS www.legrand.co.uk POWER TRACK THE QUICK-FIT VERSATILE SOLUTION Arena-Walsall
More informationAdaptive Power Module
N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive
More informationThe Power Behind Energy
CONTENTS HID ELECTRONIC BALLASTS Page 1 HID DIMMABLE ELECTRONIC BALLASTS Page 6 Copyright DNA UK LTD 11 HID ELECTRONIC BALLASTS Product Features Options of dimmable ballasts via 1-10V or IPM (Intelligent
More informationSpecification Sheet for 2D LED Light
Specification Sheet for 2D LED Light Product Features LED light source, green and energy-saving; IP54 bulkhead, available to replace a 2D fitting; PC housing and opal diffuser; 3 Hours emergency; Microwave
More informationINSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)
POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 480 Volts, 60Hz April 15, 2010: updated capacitor UL File number) Page 1 of 14 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Advantage
More informationUser's Manual Digital High Voltage Insulation Tester Model
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 380375 Product Page User's Manual Digital High Voltage Insulation
More informationFire Rated Downlights Product Catalogue
Fire Rated Downlights 2013 Product Catalogue WELCOME TO THE IMPROVED RANGE OF DETA FIRE RATED DOWNLIGHTS DETA have developed a new and improved range of Fire Rated Downlights. This new range features a
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationLEDtape 800 TW Tunable White K CRI>90
LEDtape 800 TW Tunable White 2400-6000K CRI>90 IP20/IP65 Highlights Flexible tunable white LED-tape for professional lighting applications Adjustable color temperature 2400-6000K Simulate everything from