Free Fall Fire Valve Range & Accessories

Size: px
Start display at page:

Download "Free Fall Fire Valve Range & Accessories"

Transcription

1 Free Fall Fire Valve Range & Accessories 1

2 Contents Screwed Free Fall Fire Valves... 3 Flanged Free Fall Fire Valves... 6 Free Fall Valve Accessories... 8 Fitting Kits... 8 Mercury and Non-Mercury Switches... 9 MQR Manual Quick Release EMQR Electro-Manual Quick Release E-Mag & E-Mag2 Electromagnetic Quick Release (SQR type device) Fusible Links Thermal Link Fire Valve Control Panel

3 Screwed Free Fall Fire Valves Suitable for installation in either horizontal or vertical pipe work. Designed to provide a 100% shut off when used as a fuel isolating valve. May also be used as a fuel dump valve, whereby the valve will open on actuation. Standard Free Fall Valve assembly comprises of a valve, lever and weight, together with a fitting kit. Standard valves are manufactured in cast iron to ASTM A126 Gr B. Suitable for use with fuel oils at pressures up to 14 bar. Valves with screwed connections have BSP parallel threads, whilst flanged valves are available with either BS 4504 PN 16 flange drillings or to ANSI 125. Available with carbon or stainless steel body and plug materials. Standard Fire Valves are supplied with a Lubricating Compound, which is a general purpose sealant, suitable for hydrocarbons, other Lubricating Compounds are available. May be actuated mechanically or electrically. Supplied with a Fire Valve Kit, available in sizes, Small (15 to 50mm NB valves), Medium (65 to 100mm NB valves) and Large (125 to 200mm NB valves). Kits contain Pulley Wheels, Stainless Steel Cable, Fusible Links, Warning Signs, Cable Connectors and Tension Springs, any of which may be purchased as individual products. Electrically actuated Fire Valve systems utilise a standard valve, lever and weight and use an E-MAG Electro-Magnetic Release System, allowing actuation by making or breaking an electrical circuit, usually 24V DC or 230V AC. The installation of a valve mounted Mercury Switch, Electro Mechanical Release or Wall Mounted Changeover Switch may provide remote signalling of the Fire Valve status, or allow direct switching of electrical equipment where applicable. Competitively priced with a full range of ancillaries. 3

4 Call us now: (+44) Us:

5 Call us now: (+44) Us:

6 Flanged Free Fall Fire Valves Suitable for installation in either horizontal or vertical pipe work. Designed to provide a 100% shut off when used as a fuel isolating valve. May also be used as a fuel dump valve, whereby the valve will open on actuation. Standard Free Fall Valve assembly comprises of a valve, lever and weight all finished in RAL 3000 Flame Red, together with a fitting kit. Standard valves are manufactured in ductile iron GGG40 with brass or stainless steel internals. Suitable for use with fuel oils and gases at pressures up to 14 bar. The double Viton O ring stem seals make the valve ideal for vacuum pump suction lines. Valve connections are flanged to BS 4504 PN 16. May be actuated mechanically or electrically. Supplied with a Fire Valve Kit, available in sizes, Small 15 to 50mm valves, Medium 65 to 100mm valves) and Large 125 to 200mm valves. Kits contain Pulley Wheels, Stainless Steel Cable, Fusible Links, Warning Signs, Cable Connectors and Tension Springs, any of which may be purchased as individual products. Electrically actuated Fire Valve systems utilise a standard valve, lever and weight and use an electrical Release System allowing actuation by making or breaking an electrical circuit. The installation of a valve mounted Mercury Switch, Electro Mechanical Release or Wall Mounted Changeover Switch may provide remote signalling of the Fire Valve status, or allow direct switching of electrical equipment where applicable. Competitively priced with a full range of ancillaries. 6

7 Free Fall Kit Components /4" BSP x 40mm Pulley Wheel M12 Male x 40mm Pulley /4" BSP x 40mm Anchor M12 Male x 40mm Anchor /4" BSP Backplate M12 Backplate m 316 Stainless Steel Cable m 316 Stainless Steel Cable m 316 Stainless Steel Cable Tension Spring Caution Sign for stainless cable Mechanical Free Fall System Components Caution Soldered Fusible Links C 160F C 197F C 220F C 260F C 290F Mercury Changeover Switches Single Phase 10 amp Three Phase 10 amp Release Mechanisms Manual Quick Release ElectroManual Release Screwed Free Fall Fire Valves Flanged Free Fall Fire Valves /2" " /4" /2" " " /4" " /2" " " " /2" " Spare Free Fall Kits 'Small' For 1/2" to 2" Valves 'Medium' for 2 1/2" to 4" Valves 'Large' for 5" to 8" Valves Spare Valve Sealing Compound '650' For Oil & Gas '750' for High Temp Oil & gas Electro-Mechanical Free Fall System Components Battery Trickle Chargers V ac input/3.2a/hr 24V dc Output V ac Input/6.0a/hr 24V dc Output Electro Magnetic Valve Release Mechanisms V dc Emag V ac Emag V ac Emag V dc Emag2 c/w Volt Free Contacts V ac Emag2 c/w Volt Free Contacts V ac Emag2 c/w Volt Free Contacts Remote Alarms Red 230V ac 150mm Bell Red 24V dc 150mm Bell V ac Audio/Visual Alarm Electro-Thermal Fusible Links C 160F C 194F C 205F C 218F C 330F C 360F C 440F Mercury Changeover Switches Single Phase 10 amp Three Phase 10 amp Fire Valve Control Panels V ac Input/230V ac Output V ac Input/110V ac Output Vdc Input/24V dc Output V ac Input/Battery Backed 24V dc Output Screwed Free Fall Fire Valves Flanged Free Fall Fire Valves /2" " /4" /2" " " /4" " /2" " Spare Valve Sealing Compound " " '650' For Oil & Gas /2" " '750' for High Temp Oil & gas Push Buttons & Break Glass Call Points Vac/24Vdc Emergency Knock Off Vac/24Vdc Knock Off c/w Key Release Red Break Glass Call Point Yellow Break Glass Call Point Green Break Glass Call Point 7

8 Free Fall Valve Accessories Fitting Kits Contents Individual Kit Components Product code Small Kit Contents mm to 50mm Valves Medium Kit Contents mm to 100mm Valves Large Kit Contents mm to 200mm Valves 40mm diam. ¼ BSP Pulley Double Pulley Arrangement ¼ BSP Galvanised Backplate Brass Anchor, ¼ BSP Thread 9m Stainless Cable m Stainless Cable C Fusible Link Tension Spring Cable Turnbuckle Caution Sign Cable Connectors Small Kit, for 15 to 50mm Valve Sizes Medium Kit, for 65 to 100mm Valve Sizes Large Kit, for 125 to 200mm Valve Sizes 8

9 Mercury and Non-Mercury Switches Valve mounted changeover switches provide position status via a robust volt free changeover switch, rated to 230V 10 amps, allowing direct switching of pumps or relays upon valve actuation or 0.75 amp rated nonmercury normally open switches. Single phase mercury switch assemblies house one single pole changeover switch, whilst three phase installations have three SPCO switches, housed within one enclosure. The SPCO switch is a steel encased mercury switch, potted within a dielectric resin and encapsulated within a sealed terminal enclosure, which in turn, is fixed within a grey ABS valve mounted housing. The switching action is generated by valve closure. As the valve lever travels from 45 degrees above the horizontal plane of the pipe to 45 degrees below the pipe, although both single and three phase versions can also be used with vertically mounted Free Fall Fire Valves. An alternative, NM non mercury switch assembly is also available, rated at 230V AC 0.25 amp, SPST configuration, and ideal for water industry applications or where the use of mercury as a switching media is not authorised. All Free Fall Fire Valves manufactured by FEL have predrilled levers to accept retrofitted mercury changeover switches. Single Phase Three Phase 9

10 Dimensions: /M Single Phase: 125 x 85 x 60mm Deep ABS enclosure /M Three Phase: 150 x 100 x 60 Deep Open Position Fixing Dimensions: Centres: 2 No 6.5mm diameter holes 102mm Wide to suit Fire Valve lever drilling. Electrical Ratings: /M Single Phase: 230V ac 10 amp SPCO mercury /NM Single Phase: 230V ac 0.25 amp SPST non mercury /M Three Phase: 3 x 230V ac 10 amp SPCO switches /NM Three Phase: 3 x 230V ac 0.75 amp SPST switches Closed Position 10

11 MQR Manual Quick Release Product Code Designed for use with fusible link operated free fall fire valve systems Provides manual release of fire valve system Can be used with electro-mechanical fire valve Systems 40mm red push button operation Integral shroud to prevent accidental operation Brass release spindle and 40mm pulley wheel assembly Wall or generator enclosure mounting Optional 24v DC volt free changeover switch Option Red/Green LED s for status indication Can be used in conjunction with E-Mag & E-Mag2 electro-magnetic release 11

12 MQR Enclosure Dimensions: 132 x 65 x 55mm Deep ABS Enclosure, With 40mm diameter red push button Fixing Dimensions: 2 x 4.2mm Diameter holes, Centres: 35mm wide x 95mm high 12

13 The Manual Quick Release (MQR) is designed for use with fusible link actuated fire valves. In operation, the MQR provides manual activation of the fire valve system. Pressing the red push button will release the fire valve cable tension, allowing the valve to close by gravity. The MQR is usually sited adjacent to an Exit doorway in a plant room or generator enclosure and is particulary useful for testing fire valve systems as well as providing manual fire valve closure in an event whereby an operator observes something of concern and does not want to wait for a fusible link to melt, triggering valve closure. The MQR can also be used in conjunction with a wall mounted FEL E-Mag or E-Mag2 electromagnetic fire valve release. This combination provides fire valve release options by fusible link, MQR manual operation and also electrically using an E-Mag via a fire alarm interface. 13

14 EMQR Electro-Manual Quick Release Product Code Designed for use with fusible link actuated fire valves. Provides manual activation of the fire valve system by pressing the red push button. Automatically senses the release of tension on the stainless steel fire valve cable. Internal volt free change over switch changes status, de-energising the Load terminal energising the Alarm output terminal. Safety shroud included. When tension is applied to the stainless steel fire valve cable, this will upwardly extend the spring loaded, removable spindle housed within the EMQR. By doing this, the Load terminal is energised and the Green Load Circuit lamp is illuminated. Release of tension or pressing the red push button will contract or release the spring loaded spindle and the Red Alarm Circuit lamp is illuminated whilst turning off the Load lamp. 14

15 EMQR Enclosure EMQR Enclosure Dimensions: 125 x 175 x 100mm Deep ABS enclosure, side hinged for ease of access. With 40mm diameter red push button. Fixing Dimensions: Centres: 4 No. 4.2mm diameter holes 160mm wide x 110mm high Electrical rating: Internal changeover switches are rated 230V AC 6 amps For 230V AC Operation For 24V DC Operation Term No Designation Term No Designation 1 Incoming 230V AC Live 11 Incoming 24V DC +ve 2 230V AC Neutral 12 24V DC -ve 3 230V AC to Load 13 24V DC +ve to Load 4 230V AC to Alarm 14 24V DC +ve to Alarm 5 Do Not Use 15 Do Not Use 15

16 Schematic Arrangement Tension Spring Loaded Spindle Push Button The EMQR is designed for use with fusible link actuated fire valves. In operation, the EMQR provides manual activation of fire valve system by pressing the red push button, or, it can automatically detect when a fusible link has melted by sensing the release of tension on the stainless steel fire valve cable. In either event, an internal volt free changeover switches changes status, de-energising the Load terminal energizing the Alarm output terminal. When tension is applied to the stainless steel fire cable, this will upwardly extend the spring loaded removable spindle housed within the EMQR, by doing this, the Load terminal is energized and the green Load Circuit lamp is illuminated. Release of tension or pressing the red push button will contract or release the spring loaded spindle and the red Alarm Circuit lamp is illuminated whilst turning off the Load lamp. 16

17 Call us now: (+44) Us: `

18 Call us now: (+44) Us:

19 E-Mag & E-Mag2 Electromagnetic Quick Release (SQR type device) The E-Mag and E-Mag2 Electromagnetic quick release mechanisms are for use with electrically actuated fire valve systems. They provide instant release of Free Fall Fire Valves when de-energised, making them the ideal method for remote fire valve closure. The E-Mag is a standard electromagnet, which will de-magnetise on loss of power, the E- Mag2 version has inbuilt auxilliary volt free changeover contacts, which signal valve status. Both E-Mag and E-Mag2 may be installed as wall mounted or direct mounted. Wall mounted E-Mag or E-Mag2 installations can be designed to release a stainless steel fire valve cable, which can be used in the normal way with pulley wheels and fusible link, by using an interface which will isolate a fuel supply in the event of a Fire Alarm or other means of control input by de-energising the electromagnet. Similar to the way in which an automatic fire door closes in the event of a building fire alarm. However, the system still incorporates a fusible link, providing a mechanical means of fire valve shut off as well as electrical control. Direct mounting installations have the E-Mag or E-Mag2 sited directly above the fire valve and do not incorporate a fusible link in the system, but rely upon electrical control only. Both E-Mag & E-Mag2 version include a Push to test facility and have 40Kg electromagnetic holding power as standard. For 230V AC Operation For 24V DC Operation Term No Designation Term No Designation 1 Incoming 230V AC Live 11 Incoming 24V DC +ve 2 230V AC Neutral 12 24V DC -ve 3 230V AC to Load 13 24V DC +ve to Load 4 230V AC to Alarm 14 24V DC +ve to Alarm 5 Do Not Use 15 Do Not Use 19

20 Open Position Wall mounted E-Mag or E-Mag 2 Electromagnetic Release used with soldered fusible link for electrical control with mechanical fusible link local fire protection Closed Position 20

21 E-Mag Mounting Plate, 6mm thick mild steel, with 2 x11mm diam, fixing holes at 155mm centres. Mounting plate finished solver coat Spring loaded centre overcomes any residual magnetic force when the electromagnet is de-energised Electromagnetic Face E-Mag (Electromagnetic Release) Technical Details Product Code Voltage Power Consumption Holding force V DC ZVA 40Kg V AC ZVA 40Kg V Ac ZVA 40Kg 21

22 E-Mag2 Mounting Plate, 6mm thick mild steel, with 2 x11mm diam, fixing holes at 155mm centres. Mounting plate finished solver coat Spring loaded centre overcomes any residual magnetic force when the electromagnet is de-energised Electromagnetic Face The E-Mag2 Range of electromagnetic releases mechanisms have in builds volt free changeover contacts to indicate valve status. When the E-Mag2 is de-energised, an internal relay provides a common to normally open or normally closed. E-Mag2 (Electromagnetic Release) Technical Details Product Code Voltage Power Consumption Holding force V DC ZVA 40Kg V AC ZVA 40Kg V Ac ZVA 40Kg 22

23 Fusible Links A range of fusible links, manufactured from formed brass leaves, soldered using eutectic solder, each fitted with zinc plated steel S hooks for ease of installation within a fire valve system. The use of eutectic solder, as opposed to a ranged solder, gives rise to greater accuracy at the actual fuse temperature. FEL Valves fusible links are available in the following temperatures. Also available as a Heavy Duty Link, with 45Kg maximum weight strain rating. Customised versions also available. Fusible Links Product Code Fuse Temperature (C) Maximum Weight Strain C 13Kg C 13Kg C 13Kg C 13Kg C 13Kg Technical Specification: Standard Duty Links 18swg blanks 12.5mm wide 5mm dia hole. Overall length from 47mm. Static loading up to 30lb Heavy Duty Links 16swg blanks 21mm wide 6mm dia hole. Overall length 90mm. Static loading up to 45kg 23

24 Thermal Link Product Code Product Overview Fuse Details Electro Thermal Link, contains a fuse which melts when excessive ambient temperature is detected breaking the power supply to safety valves. Electrical Rating: 10A, 230VAC Fuse melts at 72 0 C Enclosure: IP30 Single use non-resettable thermal fuse, suitable for use with standard single phase power supplies 250V (typical 230V). Approvals: VDE, SEV, UL Wiring Installation The unit should be fitted between 0.3 to 1.3m directly above the potential fire hazard with the slotted lid facing downloads. Can be suspended by metal conduit. The ventilation holes in the box must not be covered. Allow free unrestricted airflow through the enclosure. Overall Dimensions 24

25 Product Codes Electro-Thermal Links Product Code Fuse Temperature (C) Fuse Temperature (F) C 160F C 194F C 205F C 218F C 330F C 360F C 440F 25

26 Call us now: (+44) Fire Valve Control Panel Us: The FEL Fire Valve Control Panel is used to maintain power to an E-MAG or SQR type device Power Output is 24V DC, with 230V Input 24V DC Units are battery backed and designed to maintain power output in the event of mains failure whilst continuing to provide fire detection through electro-thermal links or normally closed emergency push buttons wired in series Battery backup time and battery size is calculated on the required load to maintain multiple E-Mag, Motorised Valves or SQR type devices BMS connectivity via volt free contacts Product Number: V AC input/output Fire Valve Control Panel V AC input and 24V DC Output Battery Backed 26

27 Call us now: (+44) Us: Panel Specification: Dimensions 500mm High x 400mm wide x 150mm deep Panel weight 14 Kg Fixing style Wall mounting Cable entry Bottom entry Supply 230V AC 6 amp Isolator Fascia mounted 2 pole 20 amp Internal PSU 230V AC to 24V DC, 3.5 amp, battery backed Batteries 2 x Yuasa 12V 3.1Ah in series Battery Power 1 Hour on mains failure Panel Operating Philosophy: Action Power ON MCB1 ON MCB2 ON Press 'Mute' Effect 230V Supply Healthy LED illuminates Internal PSU energised Control circuit and field supplies are energised 24VDC Supply Healthy LED illuminates Fire Valve Closed Red LED will illuminate Audible alarm will sound This will de-energise the audible alarm Sensing With sensing circuit not in alarm and a voltage on terminal 6 Circuit Press 'Reset' This will energise terminals 7 & 8 Status Switch Press 'Test' The fire valve, motorised valve or Emag will now be energised. If fitted this will energise R2 and illuminate Red fire valve closed LED This will provide a volt free output via terminals 11 &12 Fire Valve Closed' LED illuminates & Audible Alarm will sound Typical Wiring Diagram 27

28 Call us now: (+44) Us: Typical Terminal Designation: Terminal Designation: Terminal Number Voltage Designation 1 230V AC Incoming Live 2 230V AC Incoming Neutral 3 24V DC Spare 4 0V Spare 5 24V DC Sensing Circuit 24 DC 6 0V Sensing Circuit 0V 7 24DC Emag 24V DC 8 0V Emag ve 0V 9 24V DC Valve switch status 10 24V DC Valve switch status 11 Rated 230V Valve Closed Volt Free 12 Rated 230V Valve Closed Volt Free N/O 13 Rated 230V Mains Failure VF Com 14 Rated 230V Mains Failure VF NO 28

29 Call us now: (+44) Us: Did you know that we also supply the following? Float Switches Fill Point, Level Gauges, Controls Motorised Valves Pumps & Panels Fuel Polishers 29

Central Battery Systems Loadstar AC/DC Systems

Central Battery Systems Loadstar AC/DC Systems The Loadstar range of AC/DC central battery units comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources of emergency power for escape

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk Black Teknigas Powerseat Eco Gas Safety Shut-Off Valve Technical, and Maintenance Details WattsIndustries.co.uk Safety shut off valves for gas, air and oil EN161 approved; EC certificated Robust construction

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers. TransShield Mode 1/2 Transfer Stainless Steel Sliding Plate Fire Dampers www.actionair.co.uk sales@actionair.co.uk Introduction The TransShield Modes 1 and 2 stainless steels stainless steel sliding plate

More information

24V 3A EN54 Ancillary Power Supply

24V 3A EN54 Ancillary Power Supply 24V 3A EN54 Ancillary Power Supply Normal supply - green light on Fault condition - call Engineer Control relay - activated 3A Power Supply C-TEC Manufactured in England by C-Tec EN 54-4 : 1997 INSTALLATION

More information

Motorised Valve Range

Motorised Valve Range Motorised Valve Range Contents Motorised Valves... 2 Fail Safe Motorised Valves for Bio Diesel and Bio Fuels... 2 Fail Safe Motorised Valves... 3 Motor-Open Motor-Close... 6 Electro-Thermal Links... 9

More information

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J. EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual Page 1 of 10 CONTENTS 1. GENERAL...2 2. POWER REQUIREMENTS...2 2.1 HE-PSU(4.0) Input/Output Electrical Ratings...2

More information

Installation & User Instructions

Installation & User Instructions Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.

More information

EC200 ELECTRONIC CONTROL SYSTEM

EC200 ELECTRONIC CONTROL SYSTEM 1 INTRODUCING THE EC200 ELECTRONIC CONTROL SYSTEM With the use of new technology and an innovative approach to user interfacing, the EC200 Power Control System provides a complete control solution for

More information

PRECISION UK Ltd DUPLEX AGSS PLANT

PRECISION UK Ltd DUPLEX AGSS PLANT DUPLEX AGSS PLANT Contents Page Section Page Product Description General 3 AGSS Plant 3 AGSS Remote Switch 3 Operation General 4 Safety General 5 Installation General 5 Mechanical 5 Electrical 7 Wiring

More information

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave Rectifiers for use with Armature Actuated Brakes Product Overview NOTE: For brake response times with and without rectifiers see page 94. Full Wave A rectifier in which both positive and negative half-cycles

More information

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Teknigas Black Teknigas Black Teknigas Black Teknigas Black Teknigas Black Teknigas

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES FIREGARD Curtain Fire Dampers DAMPERS SFB (.) X UDC. FEBRUARY 00 FEATURES Galvanised or Stainless Steel Interlocking Blades in Airtight Casing. Optional Stainless Steel Side Seals. Constant Tension Stainless

More information

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers This brochure provides a comprehensive overview of the applications and associated functions available with Rotork Q actuators - comprising Q Standard and Q Pak actuators. The watertight Q Range actuators

More information

TABLE OF CONTENTS DISCLAMER

TABLE OF CONTENTS DISCLAMER PRODUCT CATALOGUE TABLE OF CONTENTS Introduction 2 Series 170 3 Series 178 4 Series 251 5 Series 351 7 Series 363 9 Series 800 10 Series 810 11 Series 820 12 Series 850 13 Series 900 14 Series 950 15

More information

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose OEM Emergency Portfolio Product Guide Emergency components for LED, fluorescent and auxiliary purpose Contents Introduction to this guide 3 LED Modules 4 PHL-EL3 PHL-EL3-80 PHL-EL3-D PHL-EL3-D80 PHL-EL3-4

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE 5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE MODEL# 505 ( AMP @ VDC OR 4VDC) MODEL# 5500 ( AMP @ VDC OR AMPS @ 4VDC) MODEL# 5600- (0 AMPS @ VDC) MODEL# 5600-4 (5 AMPS @ 4VDC) IMPORTANT SAFETY INSTRUCTIONS

More information

EC400 Power Control System

EC400 Power Control System 1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in section 3 or in the supporting technical manual available

More information

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006 FIREGARD Curtain Fire Dampers DAMPERS SFB (.) X UDC. AUGUST 00 FEATURES Galvanised or Stainless Steel Interlocking Blades in Airtight Casing. Stainless Steel Side Seals. Constant Tension Stainless Steel

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

K25000 & KD25000 Series

K25000 & KD25000 Series K25000 & KD25000 Series Fire Alarm Power Supplies Installation, Commissioning and Operating Manual Man-1128 Issue 14 January 2016 Man-1128_K25400_series_Power_Supply_Manual_14 Page 1 of 20 Section Page

More information

Manual for Inverter system type PCI05

Manual for Inverter system type PCI05 - 1- Manual for Inverter system type PCI05 SAFETY INSTRUCTIONS This manual must be read before installation, use or work on the product. This product contains dangerous voltages that when touched can cause

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

Installation Instructions

Installation Instructions AQU244 & AQU128 Series Installation Instructions Installation Instructions AQU244 24vdc 5A Supervised Power Supply/Charger module AQU128 12vdc 10A Supervised Power Supply/Charger module Both Mounted in

More information

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No

More information

EC225 Power Control System

EC225 Power Control System 1 Key Features 200W (~16A) combined Power Converter / Battery Charger - Converts the 230V mains supply into 12v DC power to run the leisure equipment and charge the battery using an intelligent two-stage

More information

LATEST ARRIVALS CATALOGUE STOCK

LATEST ARRIVALS CATALOGUE STOCK LATEST ARRIVALS CATALOGUE STOCK PIPES VALVES FLANGES & FITTINGS IN CARBON STEEL STAINLESS STEEL LATEST ARRIVALS!!!!!! VALVE PRODUCTS CAST IRON WAFER TYPE BUTTERFLY VALVE, PINLESS SHAFT, DUCTILE NICKEL

More information

MCD Pump Application Module

MCD Pump Application Module Overview The Pump Application Module expands the soft starter's input and output functionality and is ideal for applications where greater control and feedback are required. The module provides three digital

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

CORROSION RESISTANT IN LINE FLOW SWITCHES

CORROSION RESISTANT IN LINE FLOW SWITCHES ULTRASWITCH P20 SERIES CORROSION RESISTANT IN LINE FLOW SWITCHES Magnetically sprung piston provides exceptional reliability FEATURES SUITS TUBES & PIPES 6 TO 20 MM ( 1 /4 TO /4 ) DIA. NO METAL PARTS IN

More information

Storage Temp. ( C) Red D. Current DC (ma) Voltage Vac/dc

Storage Temp. ( C) Red D. Current DC (ma) Voltage Vac/dc features specifications Ø8.1mm mounting Product will operate over a wide voltage range Robust stainless steel housing, Sealed to IP67 Colour diffused lens Full internal potting to resist shock & vibration

More information

EMEX Power. EMEX Power. Modular AC/AC Central Battery System. EMEX Power

EMEX Power. EMEX Power. Modular AC/AC Central Battery System. EMEX Power EMEX Power EMEX Power Modular AC/AC Central Battery System EMEX Power EMEX Power Modular AC/AC Central Battery System System design The EMEX Power inverter and charger modules utilise solid state electronics

More information

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries. 1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

REVISED ATM72 Auto Transfer Module

REVISED ATM72 Auto Transfer Module Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom

More information

Emergency Lighting Products Limited

Emergency Lighting Products Limited Modern businesses are under pressure to maximise the (sales) revenue per square metre of floor space. The CEN-Power 'Compact' series of static inverters has been designed to significantly reduce the amount

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications xboard commercial and industrial panelboards xboard effectively combining safety, reliability and performance safety, reliability and performance in commercial and industrial applications NEW xboard (xdb)

More information

Motorised and automatic transfer enclosed switchess

Motorised and automatic transfer enclosed switchess s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

Versa II SLR Lubricator

Versa II SLR Lubricator Versa II SLR Lubricator With Controller General The Versa II SLR Lubricator is an automatic, robust and durable pump that can handle oil. Its compact size is designed to fit your space requirements and

More information

Climas y Proyectos Leyco, S.A. de C.V.

Climas y Proyectos Leyco, S.A. de C.V. GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA

More information

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes SERIES Features Direct mount Full Port 16 Stainless Steel ball valve 2-piece ANSI Class 150 flanged body

More information

INFRESCO-S-4kW X20034 Issue: 7

INFRESCO-S-4kW X20034 Issue: 7 INFRESCO-S-4kW X20034 Issue: 7 User Manual Date: 17/01/17 Page: 1 of 7 KEY FEATURES Extends lamp Life. Ideal for controlling up to 2 x 2kW lamps. Soft-start/zero-voltage switch-off. Low-cost. Easy to install.

More information

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information

More information

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General

More information

Mobrey 003. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP117, Rev DA. Self-contained liquid level alarm.

Mobrey 003. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP117, Rev DA. Self-contained liquid level alarm. Product Data Sheet February 2015 IP117, Rev DA Mobrey 003 Ultrasonic Liquid Level Switch Self-contained liquid level alarm Manufactured in Polyphenylene Sulphide (PPS) for corrosion resistance in most

More information

Diesel Engine Shutdown System

Diesel Engine Shutdown System Diesel Engine Shutdown System Models CSX-300, 310 CSX-301, 311 Typical applications Marine engine safety Petrochemical industry safety Vacuum trucks Cranes - both engines Land drilling rigs Offshore equipment

More information

Linear actuator. Product features. Overview. Wide range of force outputs. Wide selection of column adapters. Wide selection of flanges

Linear actuator. Product features. Overview. Wide range of force outputs. Wide selection of column adapters. Wide selection of flanges V Linear actuator Product features Wide range of force outputs Wide selection of column adapters Large stroke range Wide selection of flanges Constant positioning times under fluctuating loads Solid metal

More information

Call us now: (+44) Fuel Polishing And Filtration Equipment. Page 1

Call us now: (+44) Fuel Polishing And Filtration Equipment.   Page 1 Fuel Polishing And Filtration Equipment Page 1 Contents Fuel Polishing Systems... 3 Wall Mounted Fuel Polishers... 4 Particulate Filters... 5 Diesel Fuel Water Separators... 6 Page 2 Fuel Polishing Systems

More information

Product features & Overview. KA Linear actuators

Product features & Overview. KA Linear actuators Product features & Overview Linear actuators 66 Linear actuators Linear actuator Product features Wide range of force outputs Solid metal housing Large stroke range Maintenance-free gearbox Wide range

More information

WAFER STYLE KNIFE GATE VALVE

WAFER STYLE KNIFE GATE VALVE WAFER STYLE KNIFE GATE VALVE The model knife gate is an uni-directional wafer valve designed for general industrial service applications. The design of the body and seat assures non-clogging shut off on

More information

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES TECHNICAL AND INSTALLATION DOCUMENTATION STOKVIS ENERGY SYSTEMS UNIT 34 CENTRAL PARK ESTATE 34 CENTRAL PARK ESTATE WEST

More information

Single foot switches PX and PA series

Single foot switches PX and PA series A Single foot switches PX and PA series Selection diagram CARRYING ROD See page /10 ADDITIONAL METAL PROTECTION OPEN PROTECTIONS CLOSED PROTECTIONS PA PA 2 CONTACT BLOCKS COMBINATIONS 01 02 1NO+1NC snap

More information

SECTION B1: MACHINE COMPONENTS

SECTION B1: MACHINE COMPONENTS SECTION B1: MACHINE COMPONENTS The machine portion of the Injected Metal Assembly system provides the means for: holding, heating and injecting the alloy; distributing and controlling electrical, pneumatic,

More information

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz. 103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com

More information

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet SOLAR SMART 12/24V 20Amp MPPT Solar Charge controller with Ethernet Embedded web pages, SNMP support, output port for external Relay board and GSM SMS unit port USER MANUAL PLEASE READ THIS MANUAL CAREFULLY

More information

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS Introduction ST - II Series POWER SUPPLIES These instructions detail the installation and operation requirements for the ST20-II & ST35-II power supplies. These have been designed for operation in RV s

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations Diverting Valve Three-Way Diverting Valves can be used for temperature control in many heating and snowmelting applications. Valve Cross Section Features Includes solder tailpieces (1-1/4" and 1-1/2" models

More information

-2- Designed to automatically operate a diesel fire pump engine when the contacts of a remote water pressure switch close.

-2- Designed to automatically operate a diesel fire pump engine when the contacts of a remote water pressure switch close. -1-1 -2- FUNCTION Designed to automatically operate a diesel fire pump engine when the contacts of a remote water pressure switch close. POWER SUPPLY: 240V A.C single phase supply and 12 or 24 V D.C. INDICATORS:

More information

AMPTRON AMPTRON PRODUCT RANGE. ELECTRONICS (Pty) Ltd REG. NO: 79/02792/07. Cape Town

AMPTRON AMPTRON PRODUCT RANGE. ELECTRONICS (Pty) Ltd REG. NO: 79/02792/07. Cape Town ELECTRONICS (Pty) Ltd REG. NO: 79/02792/07 Cape Town Web site: www.amptron.co.za E-mail: amptron@adept.co.za Unit 8 Boulevard Park Off Boulevard Drive Bellville 7530 P O Box 137 Parow 7499 Tel: 27 21 9300929

More information

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided

More information

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A MODE - Multiple Occupancy Distribution Equipment Contents 4 MODE range: introduction 5 MODE

More information

Key features. DESIGNS: - Conservator type - Hermetically sealed

Key features. DESIGNS: - Conservator type - Hermetically sealed Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the

More information

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps 855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps Technical Specification Pages This page left intentionally blank. 1.0 Overview. The 855 Series is Carver s offering specifically designed to

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel, Size: 1/4 to 4 Material: 316 Stainless Steel, Carbon Steel, Alloy 20, Hastelloy C, Monel, Brass, SW, BW, BSPT, 150#, 300#, 600#, Flanged Pressure: Vacuum to 3000 PSI* -50 to 600 F* ASME B16.34 Design Bottom

More information

Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing

More information

Distribution Blocks & Bus-bar Solutions

Distribution Blocks & Bus-bar Solutions Distribution Blocks & Bus-bar Solutions Insulated Multi Laminate Flexible Copper Bus-bars Threaded Copper Bus-bars Solid Copper Bus-bars Bus-bar Insulators & Supports Insulated Flexible Copper Braided

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover www.cranepumps.com Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover Specifications: inches (mm) BASIN...Fiberglass w/ 3 (76)

More information

Zero Leakage Isolation Damper

Zero Leakage Isolation Damper SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional spigot

More information

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter. Standard AC SB5W Standard AC Intro duction Induction Reversible Right -Angle Gearheads SB5W AC Speed Control Inverter SB5W US ES2 FE1/FE2 Watertight, Dust-Resistant Torque Accessories Installation A-143

More information

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating Instructions Pedestrian Turnstile Type MPT 33 Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11

More information

Product features & Overview. N1 - N4 A Rotary and part-turn actuators

Product features & Overview. N1 - N4 A Rotary and part-turn actuators Product features & Overview N1 - Rotary and part-turn actuators 20 N1 - Rotary and part-turn actuators Rotary and part-turn actuators Product features Wide torque range Wide selection of output shafts

More information

General Description. Product Specification. Document Digital Temperature Interlock

General Description. Product Specification. Document Digital Temperature Interlock Document 474751 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the

More information

WAFER STYLE KNIFE GATE VALVE

WAFER STYLE KNIFE GATE VALVE 11 WAFER STYLE KNIFE GATE VALVE The model knife gate is an uni-directional wafer valve designed for general industrial service applications. The design of the body and seat assures non-clogging shut off

More information

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide

More information

Fire control. Electromagnetic fire Door Retainers. Available Models

Fire control. Electromagnetic fire Door Retainers. Available Models 2 Fire control Electromagnetic fire Door Retainers - Operating Voltage: 24Vdc or 240Vac - Holding Force: 55kg or 140kg - Tested and certified to EN 1155 and CE marked - Surface mounts to standard BS wiring

More information

PYTHON 1500 SERIES CONTROL VALVES. Pneumatic and Electric Actuated

PYTHON 1500 SERIES CONTROL VALVES. Pneumatic and Electric Actuated PYTHON 1500 SERIES CONTROL VALVES Pneumatic and Electric Actuated Table of Contents Features and Benefits... 3 Specifications, Weights, and Dimensions... 4-5 Trim Options and CV Values... 6 Pneumatic Actuators...

More information

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide

More information

CAUTION CM-SE CM-S21 CM-S41

CAUTION CM-SE CM-S21 CM-S41 CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1 Shutter Fire Damper Type FSD GFSD /./B/ Contents Description Description... Construction... Installation Details... Control Accessories... Technical Data... Order Details... 7 8 9 FSD-L GFSD-L FSD Fire

More information

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE EM101 LOW FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101 LOW-FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101-025 EM 101-038 EM 101-050 GENERAL INFORMATION The EM101 is a small plastic-bodied electromagnetic

More information

Installation Instructions

Installation Instructions Installation Instructions AQU243-8C1R -8F8R -8C8R 24VDC/3.3Amp Supervised (AC & Battery) Power Supply/Charger Module, 85-264vac, 14 x 9 x 3.5" Enclosure, UL294, UL603 & UL1481 Listed AQU243 with one PDB-8C1R

More information

Electromotoric Actuators

Electromotoric Actuators 4 863 Electromotoric Actuators for zone valves VVI46, VXI46, VVS46 and VXS46 SFA21/18 SFA71/18 SFA21/18 AC 230 V operating voltage, 2-position control signal SFA71/18 AC 24 V operating voltage, 2-position

More information

Neotecha NTB - NTC PFA lined ball valves

Neotecha NTB - NTC PFA lined ball valves These PFA lined ball valves are used in a wide variety of applications in many industries Features General application The valves are ideally suited for corrosive applications, requiring reliable performance,

More information

Page ATALOGUE. Web: Tel: Fax:

Page ATALOGUE. Web:    Tel: Fax: Page ACUUM PARE ANKER ARTS ATALOGUE Page 2 CONTENTS PAGE GAUGES 3 SAUNDERS M TYPE VALVES 4 LEVER BALL VALVES 5 GATE VALVES 6 AIR ACTUATED VALVES 7 KNIFE GATE VALVES 8 ACRYLIC SIGHT TUBE 9 RUBBER SUCTION

More information

AccuPower AQU126B Installation Instructions

AccuPower AQU126B Installation Instructions Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU126B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 316SS diverter valve Polyamide IP67 weatherproof enclosure with UV protection Multi-voltage

More information