Tel: &

Size: px
Start display at page:

Download "Tel: &"

Transcription

1 C O N T R O L S BRITISH QUALITY COMPANY Split Core Current Transformers & Transducers Primary Currents from 50 to 5000 Amps Accuracy Class 1 & Class Amp & 5 Amp Secondaries 0-333mV AC Transducer Output 4-20mA DC Transducer Output Choice of Aperture Sizes Click Shut & Easy Locking Protected Terminal Covers Integral Cable / Bus-Bar Pinch Screws Optional Mounting Feet Serving:- Water Industry Process Control BMS Transportation HVAC Energy Tel: &

2 Moulded case split core current transformers, all with unique clip-together features enabling a quick installation with the minimum of disturbance into existing networks without the need to disconnect in situ cabling. + TECHNICAL SPECIFICATIONS Compliance: IEC/EN , BS3938 marked: Yes Rated system voltage: Max 720V continuous Insulation: Max 3KV for 1 min Frequency range: 50-60Hz Material: Moulded case polycarbonate UL94V-0 Ambient temp range: o o -30 C to +80 C Max continuous current: 1.2 x rated current 1 + MAX CABLE SIZE mm DIA. + PRIMARIES FROM 100 AMPS TO 800 AMPS + MAX OVERALL 116x105mm + CLASS 1 (only) FOX.SC 100/5 1 1 FOX.SC 150/ FOX.SC 200/ FOX.SC 250/ FOX.SC 300/ FOX.SC 0/5 1 5 FOX.SC 500/5 1 5 FOX.SC 600/5 1 5 FOX.SC 800/5 1 5 FOX.SC O FOX.SC Maximum Width 116mm

3 2 + PRIMARIES FROM 100 AMPS TO 0 AMPS + MAX APERTURE SIZE 23x33mm + MAX OVERALL 93x106mm + CLASS 1 (class 0.5 on request, some ratios) FOX.SC23 100/ FOX.SC23 150/ FOX.SC23 200/ FOX.SC23 250/ FOX.SC23 300/5 1 5 FOX.SC23 0/ Amp secondaries available to special order, along with Class 0.5 on some ratios, please consult our sales office PRIMARIES FROM 250 AMPS TO 1000 AMPS + MAX APERTURE SIZE 82x52mm + MAX OVERALL 125x158mm + CLASS 1 (class 0.5 on request) FOX.SC23 & FOX.SC58 FOX.SC58 250/ FOX.SC58 300/ FOX.SC58 0/ FOX.SC58 500/5 1 5 FOX.SC58 600/ FOX.SC58 800/ FOX.SC / Amp secondaries available to special order, along with Class 0.5 on some ratios, please consult our sales office

4 + PRIMARIES FROM 250 AMPS TO 3000 AMPS + MAX APERTURE SIZE 82x122mm + MAX OVERALL 155x198mm + CLASS 1 (class 0.5 on request) 3 FOX.SC / FOX.SC / FOX.SC812 0/ FOX.SC /5 1 5 FOX.SC / FOX.SC / FOX.SC / FOX.SC / FOX.SC / FOX.SC / FOX.SC / FOC.SC / FOX.SC / Amp secondaries available to special order, along with Class 0.5 on some ratios, please consult our sales office. + PRIMARIES FROM 1000 AMPS TO 5000 AMPS + MAX APERTURE SIZE 82x162mm + MAX OVERALL 195x245mm + CLASS 1 (class 0.5 on request) FOX.SC / FOX.SC / FOX.SC / FOX.SC / FOX.SC / FOX.SC / FOX.SC / FOX.SC816 00/ FOX.SC / FOX.SC812 & FOX.SC816 1 Amp secondaries available to special order, along with Class 0.5 on some ratios, please consult our sales office.

5 18, 32 & 44mm ID SPLIT CORE CURRENT TRANSFORMERS & TRANSDURS 4 TYPES: FOX.SC18, FOX.SC32 & FOX.SC mm,32mm & 44mm internal diameter + Integral ratchet style cable clamp + Click shut closing action + Primary currents 50 Amps to 1000 Amps + Accuracy Class Amp, 1 Amp, 0-333mVAC, 4-20mA secondaries DESCRIPTION Very compact split core devices available as current transformers or as current sensors, ideal for retro fitting in tight for space, existing installations. Secondary outputs available are:- 5 Amp (certain ratios). 1 Amp (certain ratios) mVAC for use with energy meters such as the 333mVAC input ND range, applicable when CT s have to be mounted a distance away from the meters and the overall VA required using traditional 5 Amp or 1 amp secondary CT s is greater than the VA available from the CT, using 333mVAC alleviates this scenario. 4-20mA loop powered 24VDC, maximum loop impedance 300 Ohms. These devices feature an integral ratchet style cable fixing clamps, an easy click shut closing action and are supplied with 2.5 m of 0.75mm colour coded flying leads, 5 Amp secondary units have 0.5 m of 1.5mm of flying leads. FOX.SC18, FOX.SC32 & FOX.SC44 SPECIFICATIONS General Continuous over current: Max short time current: Max system voltage: Isolation test voltage: Isolation class: Operating temperature: Standards: marked: Max. OD A B C 1.2 x In 60 x In 1sec 720V 50-60Hz 3KV 50Hz 1min E -5 C to +50 C DIN EN60044/1 VDE 0414/1 Yes E F 4-20mA output Output: 4-20mA loop powered Loop voltage: 24VDC +/-15% Power consumption: 1W max Max loop impedance: 300 Ohms Max output on overload: 30mA Response time: <300mSec PART No A B C D E F FOX.SC FOX.SC FOX.SC

6 P/No. INTERNAL CASE OUTPUT CLASS VA DIAMETER SIZE FOX.SC18 200/1 18mm 1 1 Amp 1 1 FOX.SC18 250/1 18mm 1 1 Amp FOX.SC18 50/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 75/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 100/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 125/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 150/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 200/333mVAC 18mm 1 333mVAC 1 N/A FOX.SC18 250/333mVAC 18mm 1 333mVAC 1 N/A 5 FOX.SC32 300/5 32mm 2 5 Amp FOX.SC32 0/5 32mm 2 5 Amp 1 5 FOX.SC32 500/5 32mm 2 5 Amp 1 5 FOX.SC32 600/5 32mm 2 5 Amp 1 5 FOX.SC32 300/1 32mm 2 1 Amp 1 FOX.SC32 0/1 32mm 2 1 Amp 1 5 FOX.SC32 500/1 32mm 2 1 Amp 1 5 FOX.SC32 600/1 32mm 2 1 Amp 1 5 FOX.SC32 100/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 150/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 200/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 250/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 300/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 0/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 500/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 600/333mVAC 32mm 2 333mVAC 1 N/A FOX.SC32 100/4-20mA 32mm mA 1 N/A FOX.SC32 150/4-20mA 32mm mA 1 N/A FOX.SC32 200/4-20mA 32mm mA 1 N/A FOX.SC32 250/4-20mA 32mm mA 1 N/A FOX.SC32 300/4-20mA 32mm mA 1 N/A FOX.SC32 0/4-20mA 32mm mA 1 N/A FOX.SC32 500/4-20mA 32mm mA 1 N/A FOX.SC32 600/4-20mA 32mm mA 1 N/A FOX.SC44 250/5 44mm 3 5 Amp FOX.SC44 300/5 44mm 3 5 Amp FOX.SC44 0/5 44mm 3 5 Amp 1 5 FOX.SC44 500/5 44mm 3 5 Amp 1 5 FOX.SC44 600/5 44mm 3 5 Amp 1 5 FOX.SC44 800/5 44mm 3 5 Amp 1 5 FOX.SC /5 44mm 3 5 Amp 1 5 FOX.SC44 250/1 44mm 3 1 Amp FOX.SC44 300/1 44mm 3 1 Amp FOX.SC44 0/1 44mm 3 1 Amp 1 5 FOX.SC44 500/1 44mm 3 1 Amp 1 5 FOX.SC44 600/1 44mm 3 1 Amp 1 5 FOX.SC44 800/1 44mm 3 1 Amp 1 5 FOX.SC /1 44mm 3 1 Amp 1 5 FOX.SC44 250/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 300/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 0/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 500/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 600/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 800/333mVAC 44mm 3 333mVAC 1 N/A FOX.SC /333mVAC 44mm 3 333mVAC 1 N/A FOX.SC44 0/4-20mA 44mm mA 1 N/A FOX.SC44 300/4-20mA 44mm mA 1 N/A FOX.SC44 250/4-20mA 44mm mA 1 N/A FOX.SC44 500/4-20mA 44mm mA 1 N/A FOX.SC44 600/4-20mA 44mm mA 1 N/A FOX.SC44 800/4-20mA 44mm mA 1 N/A FOX.SC /4-20mA 44mm mA 1 N/A SPECIFICATION

7 C O N T R O L S NORTONICS FOXTAM LIMITED HEAD OFFI: Bridge Road, Camberley, Surrey GU15 2QR Tel: +44 (01276) Fax: +44 (01276) MANUFACTURING: Foxtam House, Watts Street, Chadderton, Oldham, Lancs Ol9 9LQ Tel: +44 (0161) Fax: +44 (0161) sales@nortonicsfoxtam.co.uk Tel: & Edition

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications: CTB 31.35 Plug-in current transformer Dimensions: Primary conductor 1: 30x10 mm Primary conductor 2: 25x12 mm Primary conductor 3: 20x20 mm Round conductor: 26 mm Transformer width: 60 mm Transformer height:

More information

Current transformers. Current transformers

Current transformers. Current transformers Current transformers Current transformers Moulded case current transformer Moulded case CT, class 1 and 0.5 / 5 A Increased reliability Both halves of the housing overlap rather than butting up against

More information

Basic Series Accessories Low Voltage Current Transformer Class 1

Basic Series Accessories Low Voltage Current Transformer Class 1 Low Voltage Current Transformer Class 1 Current Transformer Current transformers for direct mounting to bus bars or insulated round conductors. Application: indirect measurement of sinusoidal alternating

More information

SPLIT-CORE DC CURRENT TRANSDUCER

SPLIT-CORE DC CURRENT TRANSDUCER SPLIT-CORE DC E6 Applying laminated split core technology and open loop technology split core DC current transducer is designed for strong durability. It improves not only existing errors at the low current

More information

DIN Rail Mounting Bracket

DIN Rail Mounting Bracket DIN Rail Mounting Bracket Fits Simpson Hawk 3, Falcon and Counters Fits Standard Din Rail C 1 4.30 2.55 3.85 Din Rail Adapter 44 Enclosure: Attachment Clips: Stiffeners: Installed depth: UL94V-0 Rated

More information

SIGMA SERIES DE METER

SIGMA SERIES DE METER SIGMA SERIES DE METER Analogue Meters www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

PLATINUM SERIES SWITCHBOARD METERS

PLATINUM SERIES SWITCHBOARD METERS PLATINUM SERIES SWITCHBOARD METERS www.sifamtinsley.co.uk DATASHEET E471457 Multifunction Meters Transducers & Isolators PLATINUM SERIES SWITCHBOARD METERS Temperature Controllers Converters & Recorders

More information

Center Winder Specification

Center Winder Specification Center Winder Specification Bump Roll Edge Guide Photo Eye 2000 Ft/ Min Dancer Arm Center Winder Overview Winding is simply a rotational means to take up and package material for more efficient handling

More information

Super Calendar. Heated rolls

Super Calendar. Heated rolls Application Assistant Surface Winders are used to roll up material such as wire, paper, film, metals and textiles. The surface winding method applies the driving power to a fixed diameter roll or rolls,

More information

Super Calendar. Heated rolls

Super Calendar. Heated rolls Application Report Surface Winders are used to roll up material such as wire, paper, film, metals and textiles. The surface winding method applies the driving power to a fixed diameter roll or rolls, on

More information

ANSI Switchboard Meters

ANSI Switchboard Meters ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged

More information

SPAN CONTROLS. For Quality, Reliability And Service

SPAN CONTROLS. For Quality, Reliability And Service Span Controls Established in 1987, Span Controls is now one of the leading manufacturers of Switch Mode Power Supplies, Battery Chargers, DC-DC Converters and LED Drivers in India. Having more than 25

More information

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter 212, 312 & 412 Vista Series Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as

More information

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped

More information

1. Table of Contents T-LINE. Page. 1. Table for contents Description Current transformers type HF Product Overview 4

1. Table of Contents T-LINE. Page. 1. Table for contents Description Current transformers type HF Product Overview 4 T-LINE 1. Table of Contents Page 1. Table for contents 2 2. Description Current transformers type HF 3 3. Product Overview 4 4. Measuring accuracy VA Burden 5 5. Survey chart 0,5 1 3, type HF3A, HF3B and

More information

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS Application: The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as per industrial standard case size. Available Models:

More information

Technical Data Sheet Sigma Series DE Meter

Technical Data Sheet Sigma Series DE Meter Technical Data Sheet Sigma Series DE Meter The moving iron panel meters, DE 48/72/96/144 are housed in a moulded polycarbonate cases which are suitable for the measurement of AC currents for frequency

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

Standard Program Technical Description

Standard Program Technical Description Standard Program Technical Technical Square Panel Meters Square panel meters per DIN 43700 with quadrant scale, dull black or dull gray (RAL 7037) bezel per DIN 43718.. Interchangeable Scales Meter s scale

More information

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...

More information

Smart Look Series Meter

Smart Look Series Meter File No. E471457 Technical Data Sheet Smart Look Series Meter 1/2 The moving iron & moving coil panel meters sizes 2 " 1/2, 3 " are housed in a moulded polycarbonate cases which are suitable for the measurement

More information

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter C R LISTED File No. E471457 Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as

More information

Current Switches and Transducers

Current Switches and Transducers Current Switches and Transducers Models CT-800,-805, -810, -815, -820, -825, -830 and CU-850, -855, -860, -865, -870, -875, -880, and -885 Easy to install... Small size, built-in mounting flanges, and

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

Technical Data Sheet Sigma Series DS Meter

Technical Data Sheet Sigma Series DS Meter Technical Data Sheet Sigma Series DS Meter The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments

More information

AC Wattmeters and VArmeters

AC Wattmeters and VArmeters AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

Century Style Analog Panel Meters

Century Style Analog Panel Meters UL Recognized File # E91015 Except for the Wattmeters and Frequency Meters Glass window for optimum viewing Rugged black plastic case Black knife-edge pointer for precision reading The Specifications &

More information

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load 100 series Single, Dual, Triple Output DC/DC Converter DESCRIPTIONS FEATURES Synchronization 13.3W/In 3 Power Density Efficiency to 87% UL 190 Approved VDE / EN 90 Approved >700,000 Hours MTBF 6 sided

More information

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96 Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide

More information

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0 TC-500PD8 TC-500PD8 Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION Revision: 2.0 727,. Phillips Drive City of Industry. CA 91748. USA http:// www.xeal.com.tw TEL: 626-303-8885 FAX: 626-301-0588

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

Explosion Proof Drop Light - 12 Volt AC/DC Watt Incandescent - 25' Cord - Twist Lock Plug

Explosion Proof Drop Light - 12 Volt AC/DC Watt Incandescent - 25' Cord - Twist Lock Plug Explosion Proof Drop Light - 12 Volt AC/DC - 100 Watt Incandescent - 25' Cord - Twist Lock Plug Part #: EPL-DL-12-25 Made in the USA The Larson Electronics EPL-DL-12-25 Explosion Proof Hand Lamp is U.L.

More information

Power Supplies. Series FLEX Power Supplies...P2 Technical Information & Dimensions (Online)...P5. ADEL Power Supplies

Power Supplies. Series FLEX Power Supplies...P2 Technical Information & Dimensions (Online)...P5. ADEL Power Supplies ower Supplies Series...2 Technical Information & Dimensions (Online)...5 ADEL ower Supplies 1 Flexible Switching ower Supplies Sprecher + Schuh is proud to bring you a Flexible ower Supply from the best

More information

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%] Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Built-in EMC Filter Ribbed Case Style 22VDC Isolation Wide 4:1 Input Voltage Range EN-522 Class B The

More information

Applications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives.

Applications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives. Applications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives a c d b e Selection Guide (partial) Part No. Case Size Output

More information

Technical information

Technical information Technical information General Regulations WTL current transformers are special transformers which transfer the primary circuits with prescribed accuracy in smaller secondary circuits. Primary and secondary

More information

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed.

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed. CT/LT Turbine Flow Meters User Manual CT/LT Durchflussturbinen Bedienungsanleitung Manuel d utilisation des débitmètres à turbine CT/LT Manual de usuario para los caudalímetros de turbina serie CT/LT www.webtec.com

More information

DIN Panel Meters Long Scale

DIN Panel Meters Long Scale DIN Panel Meters Long Scale A range of 72mm and 96mm DIN style panel meters measuring all electrical parameters and featuring moving coil movements. All meters incorporate slide-in dials and terminal covers

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%] Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Built-in EMC Filter Baseplate Case Style 2250VDC Isolation Wide 4:1 Input Voltage Range EN-50155 and

More information

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS POWER FACTOR METERS - LF 72 / LF 96 Analogue Meters www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

Electro Controls. Current Switches / Sensors WattsIndustries.co.uk

Electro Controls. Current Switches / Sensors WattsIndustries.co.uk Electro Controls Current Switches / Sensors - 2017 WattsIndustries.co.uk Current Switches / Sensors Section 17 CURRENT SWITCHES FIXED SWITCH POINT ESOL.... These units are powered by induction from the

More information

PRODUCTS: POWER SUPPLY

PRODUCTS: POWER SUPPLY PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER

More information

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /1 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals IO Input/Output Modules IO-ABM4 Analogue Override Module Description IO-ABM4 Analogue Override Module Intended for applications which require independent manual override of analogue output channels from

More information

Metering Products Protection Units Current Transformers. April 1, 2015

Metering Products Protection Units Current Transformers. April 1, 2015 Metering Products Protection Units Current Transformers April, 0 With Effect From April, 0 Sr.No Description Model No. Multifunction LED Meters POWER ANALYZER - LED VIPS 80P 00 POWER ANALYZER - LED 0-

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

Technical Data Sheet Sigma Series DG Meter

Technical Data Sheet Sigma Series DG Meter Technical Data Sheet The moving coil, recti er meters, DG 48/72/96 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages. Special Features Less VA burden. Linear

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE ROGOWSKI CURRENT TRANSDUCERS INSTRUCTIONS FOR USE RCTi and RCTi-3ph POWER ELECTRONIC MEASUREMENTS Ltd. Gloucester House, Wellington Street, Long Eaton, Nottingham, NG10 4HT, U.K. Tel: +44 115 946 9657

More information

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST

More information

KM Metering Inc. Product Catalog Smart Meters. EKM-Omnimeter Pulse v.4. EKM-Omnimeter II UL v.3

KM Metering Inc. Product Catalog Smart Meters. EKM-Omnimeter Pulse v.4. EKM-Omnimeter II UL v.3 Product Catalog Smart Meters EKM-Omnimeter Pulse v.4 Our Most Advanced Universal Smart Meter now with the ability to count pulses from three pulse-output devices, and the ability to control two relays.

More information

Switching Power Supplies

Switching Power Supplies Features Boxed Power Supplies with Screw Terminal Block Single- and Triple Output Models EMI Compliance with EN 55022 and FCC Part 15, Level B Short Cirquit Protection Overvoltage Protection High Efficiency

More information

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%] Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Baseplate Case Style 2250VDC Isolation Wide 4:1 Input Voltage Range EN-50155 and EN-50121-3-2 Certified

More information

Installation and Operation Instructions DLP Series

Installation and Operation Instructions DLP Series Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW

More information

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE TRANSDUCERS. Specifications. Individual Specifications 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need

More information

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER Advanced Clamp-on Transit-time Ultrasonic Flow meter for Accurate Flow Measurement Features: Cost effective and versatile High accuracy, better than ±1.0% read

More information

65 Watt High Intensity LED Light - 120/277V AC ft Spot Beam - 6.7" OD Light Head

65 Watt High Intensity LED Light - 120/277V AC ft Spot Beam - 6.7 OD Light Head 65 Watt High Intensity LED Light - 120/277V AC - 3000ft Spot Beam - 6.7" OD Light Head Part #: LED65WRE-1227 Buy American Compliant The LED65WRE-1227 LED Spotlight is ideal for a wide variety of uses including

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements. Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER EVI 7 S8 Solenoid System COIL The EVI7 S8 system by AMISCO includes a wide range of solenoid operators designed for pneumatic valves. All solenoids of this system have the guide tube with a diameter of

More information

Proportional Pressure Reducing Valve PDM08130

Proportional Pressure Reducing Valve PDM08130 Proportional Pressure Reducing Valve PDM08130 up to 80 bar up to 10 l/min Cartridge valves Control electronics Connection housings 486 1. DESCRIPTION 1.1. GENERAL According to DIN-ISO 1219, HYDAC proportional

More information

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF Features Switching Regulator Description Efficiency up tpo 94%, no need for heatsinks Pin-out compatible with LM78XX linears Low profile (L/W/H=11.5 x 7.5 x 1.2mm) Wide input range Short circuit protection,

More information

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017 HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH

More information

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % FEATURES Industrial Standard Quarter Brick Package Wide Input Range 43-101VDC & 66-1VDC Excellent Efficiency up to 92% I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp. Range - C

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac.

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac. Solid State Relays Vdc Input/ Output, Input/ Output High Reliability Shown smaller than actual size ac Controlled used with Controller with dc Voltage Driver Output L Typically ac Controlled used with

More information

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY RETROFIT KITS BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B, CO Retrofits BE1-50/51B,

More information

CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES

CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES ECT-4 DATASHEET CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES Excellent mobility Single handed operation Extended operating time Three discrete current injection levels Continuous & pulsed

More information

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1 15 mm Pilot Valve The 15 mm pilot valve has been designed and developped by Amisco as a logical evolution of the traditional product range manufactured for the pneumatic market. The 15 mm solenoid valve

More information

9 Watt High Output LED Light Emitter on Magnetic Base Goose-Neck Arm V

9 Watt High Output LED Light Emitter on Magnetic Base Goose-Neck Arm V 9 Watt High Output LED Light Emitter on Magnetic Base Goose-Neck Arm - 120-277V Part #: LED40W-GNM Page: 1 Made in the USA The LED40W-GNM LED High Output LED Light Emitter on Adjustable Gooseneck Arm and

More information

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1 SPECIFICATION FSP350-60APN(85) Bronze (Erp2013) DATE:MAY, 14, 2013 REV:2 表單編號 :7000P-0105 Page1 TABLE OF CONTENTS PAGE 1. GENERAL REQUIREMENTS 3 2. INPUT REQUIREMENTS 3 3. OUTPUT REQUIREMENTS 3 3.1 Output

More information

Metering Products. Metering Products Protection Units April 1, Price List. Price List. With effect from April 1,

Metering Products. Metering Products Protection Units April 1, Price List. Price List. With effect from April 1, Price List Metering Products Metering Products Protection Units With Current effect from Transformers April, 20 With effect from April,20 E-mail: marketing@veritekindia.com Telephone: 022-6294268 Sr.No

More information

300 Watt LED Pole Top Light Fixture VAC W Metal Halide Equivalent - Slip Fit Yoke

300 Watt LED Pole Top Light Fixture VAC W Metal Halide Equivalent - Slip Fit Yoke 300 Watt LED Pole Top Light Fixture - 120-277VAC - 1000W Metal Halide Equivalent - Slip Fit Yoke Part #: GAU-PT-60X5W-ACS-1227 Page: 1 Made in the USA The GAU-PT-60X5W-ACS-1227 High Output LED Pole Top

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

SST-ST75F-ESS The essential silver standard

SST-ST75F-ESS The essential silver standard STRIDER ESSENTIAL SERIES SST-ST75F-ESS The essential silver standard High efficiency with 80 PLUS Silver certification 24/7 continuous power output with 40 operating temperature Class-leading single +12V

More information

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE TRANSDUCERS. Specifications. Individual Specifications GEMS COMPLIANT 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 00 psi to 0-0,000 psi ranges (0- bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For

More information

Safety Lampholders and Pendants

Safety Lampholders and Pendants Safety Lampholders and Pendants Safety products are designed to make life easy for you. When the lamp is removed from the lamp holder body the power is automatically disconnected at the contacts - ensuring

More information

ELECTRICAL PANELS. Chap.

ELECTRICAL PANELS. Chap. ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch

More information

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com

More information

Non-Spring Return EconoDrive Floating Actuator

Non-Spring Return EconoDrive Floating Actuator MF4D-0x Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All

More information

ComfortPoint Programmable Lon, VAV/Unitary Controllers

ComfortPoint Programmable Lon, VAV/Unitary Controllers ComfortPoint Programmable Lon, VAV/Unitary Controllers Controller Model Programmable Type Universal Inputs (UI) Table 1. Controller configurations. Digital Inputs (DI) PRODUCT DESCRIPTION INSTALLATION

More information

PHOENIX CONTACT

PHOENIX CONTACT Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers

More information

Fire Rated Downlights Product Catalogue

Fire Rated Downlights Product Catalogue Fire Rated Downlights 2013 Product Catalogue WELCOME TO THE IMPROVED RANGE OF DETA FIRE RATED DOWNLIGHTS DETA have developed a new and improved range of Fire Rated Downlights. This new range features a

More information

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R 750 kva Transformer - 12470V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R Part #: MT-PMD-3P-12470D-750KVA-480Y.277-N3R Page: 1 The MT-PMD-3P-12470D-750KVA-480Y.277-N3R 12470D 3 Phase

More information

LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord

LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord Part #: WAL-DL-LED-12 Page: 1 Made in the USA The WAL-DL-LED-12 from Larson Electronics is a LED Drop Light / Work Light

More information

Spyder BACnet Programmable Controllers

Spyder BACnet Programmable Controllers Spyder BACnet Programmable Controllers Controller Model Programmable Type Table 1. Controller configurations. INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The PUB and PVB controllers are part of the Spyder

More information

DIGITAL EARTH LEAKAGE RELAY

DIGITAL EARTH LEAKAGE RELAY EARTH LEAKAGE (ELR) WITH CORE BALANCE Features ŸDigital Microprocessor / Microcontroller based compact design. ŸContinuous monitoring and display of set value and measured value of leakage current. Ÿ8

More information

A.C. 90 & 240º SCALE AMMETERS & VOLTMETERS

A.C. 90 & 240º SCALE AMMETERS & VOLTMETERS A.C. 90 & 2º SCALE AMMETERS & VOLTMETERS Rated burden (ammeter) 1 VA (range 5A) Continuous overload 1.2 In / 1.2 Vn Instantaneous overload In / 2Vn Accuracy 1.5% Operating temperature - + C Manufactured

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS

More information

Current transformers

Current transformers FUNCTIONS AND CHARACTERISTICS Current transformers Technical Datasheet Schneider Electric is the global specialist in energy management with the most complete power monitoring product line. Current Transformers

More information