Components Power Supplies and Converter DC/AC Converter Generic Product Catalog

Size: px
Start display at page:

Download "Components Power Supplies and Converter DC/AC Converter Generic Product Catalog"

Transcription

1 Components Power Supplies and Converter DC/AC Converter Generic Product Catalog

2

3 Power Supplies and Converter - DC/AC Converter Table of Contents Introduction DC/AC Converter... 1 DC/AC Converter Typologies 5 kva DC/AC Converter kva DC/AC Converter... 7 Appendix Notes Traceability of Reviews Table of Reviews This publication is AECMA S1000D compliant. I

4 Generic Product Catalog II All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

5 Power Supplies and Converter - DC/AC Converter DC/AC Converter Construction features "Power supply systems with static converters" are suitable for outdoor use in places located near the track. The rack and all the internal metallic accessories, including screws and nuts, are AISI304 stainless steel. Racks with max 6kVA power shall be installed on pole. Racks with power between 6kVA and max 200kVA shall be installed at ground level on a cement bedplate with connection cable inlet from the bottom and/or from the top. Power cord features 50kV isolation at 50 Hz and 125 kv pulse and is fitted with a metallic screen of at least 70nmq. Every device is fitted with proper anti-vibration systems. The protection class with doors closed is IP54. The protection class with open doors, for both the MT (medium voltage) and bt (low voltage) compartments, is IPXXB at least. MT/bt compartments can only be accessed after removing the appropriate panels using the tools provided for the purpose. Suitable warning signs shall be affixed on every removable part that provides access to live components and/or energizable components. Functions Whatever internal malfunctioning affecting the converter, including sectioning device, fuse and arrester, won't have effect on the continuity of the 3.6 kvdc power supply line. Connecting cable screen discharge (if any) to the dc line will trigger the fuse. Fuse operation is monitored via the status change of an electric clean contact (fuse tripping) connected to the terminal block. Automatic operating time is lower than 15 seconds from when voltage will be present on the dc line, voltage can be regulated between 2200 and 3300 Vdc. Energy quantities Supplied energy quantities feature one minute sampling rate and are stored in a memory which can be consulted for a thirty-years period. Functions towards the outside It has been provided the transmission via fiber optic terminal, supported by standard FS protocol, of controls and diagnostic data concerning: - local/remote service selection - control and monitoring converter on/off - on/off indication - power-on number counter - Counter of the number of automatic shutdowns due to input overvoltage and undervoltage - Permanent monitoring of the connection integrity of the negative reference wire and issue of the relevant alarm for negative connection break. - Alarm for current passing through power cord screen connected to the TE protection circuit. - MT fuse tripping indication. - Disconnector on/off state. - Input voltage measure. - Internal temperature on at least two different stages of the pole-installed device and four on ground-installed devices.. Ancillary equipment Systems come with the following accessories: Pole-type version: - Lower support complete with bolts for universal fastening on poles of the "M" type and "LS" type (collars excluded). - Upper support complete with bolts for universal fastening on poles of the "M" type and "LS" type (collars excluded). - Single-pole disconnector with MT fuse and fuse holder, complete with hand winch with transmission operation from the bottom (operating rod excluded). Introduction Converter activation after manual or automatic disconnector making is subject to a local/remote switch: in local it will be of the manual type whereas in remote it will be of the automatic type. Selectable (local/remote) activation control/procedure has been provided. Exceeding the frequency range and/or the output voltage will result in converter shutdown. In case of power absorption > 100% than rated power, the converter will limit current to the max admitted value. In case of output short circuit, a protection circuit for electronic components will limit the current to 150% peak of the nominal current; should this condition last, an output automatic breaker will cut-in. Connection continuity to CDTE and to CPTE is monitored. Ground-type version: - Single-pole disconnector with MT fuse and fuse holder, complete with hand winch with transmission operation from the bottom (operating rod excluded). - MT cable, 10 meters. CDTE and CPTE connection continuity checks Connection or CDTE or CPTE lack of continuity will result in converter locking within max 100 ms. Converter is reconnected following the sequence below: 1. Open the disconnector on MT side 2. Reset CDPE or CPTE connection or connections 3. Close the disconnector on MT side. Rack structure Rack structure is in press-bent sheet plate with first-class, 15/10 nm thickness, AISI 304 rolled steel sections, painted externally with RAL 7044 color. Optional accessories MT disconnector remote control motorization. This publication is AECMA S1000D compliant. 1

6 Generic Product Catalog Electrical characteristics: Vdc external power supply - Remote local selector - Electrical/mechanical lock of the two positions. - Extraction key on open position from local. - Local opening/closing both electrical and manual. Introduction Mechanical characteristics: - Point machine preset for both piling installation and installation on "M" and "LS" poles - Steel structure, 15/10 thickness - External painting RAL Door with key-lock, FS standardized type. 2 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

7 5 kva DC/AC Converter Power Supplies and Converter - DC/AC Converter The 5 kva version, to be pole-installed and to be used for powering signaling huts, TxD system shelters located along the line, line lighting systems for TE system maintenance, tunnel lighting systems, points heating BTS systems for small-layout stations, etc. DC/AC Converter Typologies This publication is AECMA S1000D compliant. 3

8 Generic Product Catalog DC/AC Converter Typologies General Features Part number: Format: Size [l, h, d] [mm]: Front Panel: MTBF [h]: 700, 1.400, 550 > load max. Weight [g]: Front panel color: RAL7044 Working temperature [ C]: Storage temperature [ C]: Vibrations: Altitude[m]: Relative humidity: < % (@ 30 C) non-condensing Composition: Obsolescence: HW revision: SW revision: SW file: Naming: Certifications and conformity: CEI EN ; CEI 64-8; CEI EN ; CEI EN 50119; CEI 20-13; CEI 20-38; IS 365/ ed.2008; IS 402 A ed.2000; IS 728 ed no Technical Features Power supply Power supply system nominal voltage [kvdc]: 3,6 Max permanent voltage [kvdc]: 3,6 Max non-permanent voltage Umax2 (t < 5') [kvdc]: 3,9 Max transient no-load voltage Umax3 (t = 20 ms) [kvdc]: 5,2 Output Single-phase/three-phase output voltage [Vac]: 230 ± 1% Frequency [Hz]: 50 ± 1%; Ripple: 125% max. per 5' Rack characteristics Paint flatness degree: < 25 gloss Paint thickness [μm]: 70 typ. (40 min.) Paint type: Polyester powder Protections In the event of power absorption > 100% than nominal power, converter will limit current to the max admitted value. In the event of output short-circuit, there is a circuit fitted which protects the electronic components by limiting current to 150% nominal current peak; output automatic switch is also fitted. Ground isolation voltage monitoring with safety circuit intervention to prevent dangerous accidental contacts. Remote diagnostics via fiber optic link; transmission via fiber optic terminal supported by FSIEC870.5 standard protocol of diagnostic controls and data concerning: 1. On/Off 2. Running hours 3. Power-on number 4. Number of shutdowns due to input overvoltage/undervoltage 5. Ground failure alarm 6. Input voltage measurement 7. Output Power measurement 8. Inner temperature into the two stages 9. Permanent control of the integrity of the connection of the negative reference conductor 10. Local/remote operating choice 11. On/off warning 12. Fuse release 13. On/off sectioning switch state MTTR: < 30' Technical features subject to variation without notice. Schematic 4 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

9 Power Supplies and Converter - DC/AC Converter DC/AC Converter Typologies 1. Air extraction 2. Control board first stage 3. First stage magnetic 4. Capacitor HV 5. Second stage control boards 6. Filter capacitors 7. Inductor filter 8. Isolation trasformers 9. Antivibration support 10. Protection grid 11. Natural air sinks converter This publication is AECMA S1000D compliant. 5

10 DC/AC Converter Typologies Generic Product Catalog Example of installation on long pole line, ver. 5kVA 6 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

11 40 kva DC/AC Converter Power Supplies and Converter - DC/AC Converter The 40 kva version, to be ground-installation along the line and to be used for powering signaling huts, TxD system shelters located along the line, line lighting systems for TE system maintenance, tunnel lighting systems, points heating BTS systems for small-layout stations, etc. DC/AC Converter Typologies This publication is AECMA S1000D compliant. 7

12 Generic Product Catalog DC/AC Converter Typologies General Features Part number: Format: Size [l, h, d] [mm]: Front Panel: MTBF [h]: 810, 880, > load max. Weight [g]: Front panel color: RAL7044 Working temperature [ C]: Storage temperature [ C]: Vibrations: Altitude[m]: Relative humidity: < % (@ 30 C) non-condensing Composition: Obsolescence: HW revision: SW revision: SW file: Naming: Certifications and conformity: CEI EN ; CEI 64-8; CEI EN ; CEI EN 50119; CEI 20-13; CEI 20-38; IS 365/ ed.2008; IS 402 A ed.2000; IS 728 ed no Technical Features Power supply Power supply system nominal voltage [kvdc]: 3,6 Max permanent voltage [kvdc]: 3,6 Max non-permanent voltage Umax2 (t < 5') [kvdc]: 3,9 Max transient no-load voltage Umax3 (t = 20 ms) [kvdc]: 5,2 Output Single-phase/three-phase output voltage [Vac]: 400 ± 1% Frequency [Hz]: 50 ± 1%; Ripple: 125% max. per 5' Rack characteristics Paint flatness degree: < 25 gloss Paint thickness [μm]: 70 typ. (40 min.) Paint type: Polyester powder Protections In the event of power absorption > 100% than nominal power, converter will limit current to the max admitted value. In the event of output short-circuit, there is a circuit fitted which protects the electronic components by limiting current to 150% nominal current peak; output automatic switch is also fitted. Ground isolation voltage monitoring with safety circuit intervention to prevent dangerous accidental contacts. Remote diagnostics via fiber optic link; transmission via fiber optic terminal supported by FSIEC870.5 standard protocol of diagnostic controls and data concerning: 1. On/Off 2. Running hours 3. Power-on number 4. Number of shutdowns due to input overvoltage/undervoltage 5. Ground failure alarm 6. Input voltage measurement 7. Output Power measurement 8. Inner temperature of the two stages 9. Permanent control of the integrity of the connection of the negative reference conductor 10. Local/remote operating option 11. On/off warning 12. Fuse release 13. On/off sectioning switch state MTTR: < 30' Technical features subject to variation without notice. Schematic 8 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

13 Power Supplies and Converter - DC/AC Converter DC/AC Converter Typologies 1. Solar irradiation protection 2. Cabinet ventilation 3. Protection grid 4. Capacitor HV 5. Control board 1 stage 6. Power converter heat sink 7. Control board 2 stage 8. Filter capacitors 9. Inductor filter 10. Isolation transformer 11. Antivibration support This publication is AECMA S1000D compliant. 9

14 DC/AC Converter Typologies Generic Product Catalog Example of ground-installation along the line, ver. 40 kva 10 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

15 Power Supplies and Converter - DC/AC Converter Notes Appendix This publication is AECMA S1000D compliant. 11

16 Appendix Generic Product Catalog 12 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

17 Power Supplies and Converter - DC/AC Converter Table of Reviews REV. DATE Prepared Approved Authorised Revision Reason /07/2010 Bottino D. Vernazza M. Casazza A. Traceability of Reviews This publication is AECMA S1000D compliant. 13

18 Generic Product Catalog 14 All Rights Reserved. Passing and copying of this document or part of it, use and communication of its contents is not permitted without authorization. Ansaldo STS.

19 Property of Ansaldo STS SpA, all rights reserved. The copying, reproduction and use of this work in any form whatsoever is forbidden without the written authorization of Ansaldo STS SpA.

20 Ansaldo STS SpA Via Paolo Mantovani Genoa Italy

DC POWER SUPPLY SYSTEMS

DC POWER SUPPLY SYSTEMS DC POWER SUPPLY SYSTEMS double branch Rectifier - SCR type TITANIUM 2R-SCR PLUS SERIES TITANIUM 2R-SCR rectifier series belongs to the Double Branch category thus provided with two independent AC / DC

More information

designing and producing a wide range of railway power converters and devices since 1986 FOCUS ON TRANSPORT ELECTRONICA

designing and producing a wide range of railway power converters and devices since 1986 FOCUS ON TRANSPORT ELECTRONICA designing and producing a wide range of railway power converters and devices since 1986 FOCUS ON TRANSPORT ELECTRONICA TROLLEYBUS CATENARY SUPPLIED BATTERY CHARGER The trolleybus catenary supplied battery

More information

AME. Rectifier - Battery charger. Industrial applications: Key features:

AME. Rectifier - Battery charger. Industrial applications: Key features: Rectifier - Battery charger AME VRLA batteries, flooded battery or Ni/Cd with output voltage from 24, 48, 110, 220 Vdc up to 150A Industrial applications: Oil&Gas (Petrochemicals Offshore, Onshore, Pipelines);

More information

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants World Class Power Solutions Rectifiers For Stationary Battery Systems in Nuclear Power Plants General 2 1.1 Application Electronically controlled rectifier assemblies are used in conjunction with suitable

More information

Manual for Inverter system type PCI05

Manual for Inverter system type PCI05 - 1- Manual for Inverter system type PCI05 SAFETY INSTRUCTIONS This manual must be read before installation, use or work on the product. This product contains dangerous voltages that when touched can cause

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy. Type SDV6 distribution circuit breaker Top performance - proven reliability Answers for energy. Table of contents Introduction 2-4 Type 3AH3 stored-energy operating mechanism 6 Vacuum interrupters 7 Ratings

More information

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications Medium voltage products UniSec Y800 New 24 kv air-insulated medium voltage switchgear to e-istribuzione specifications UniSec Y800 ubicles available Unit e-istribuzione specifications (Ed. 4) UniSec IS/1

More information

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0 Products Tde Macno User s Manual BRAKING UNIT Cod. MP00401E00 V_1.0 SUMMARY 1 GENERAL DESCRIPTION... 2 2 USE LIMITATIONS... 2 2.1 Climatic Class... 2 2.2 Resistance To Chemically Active Substances...

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery

More information

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0 PRO POWER 2 0 A L I T H I U M B AT T E RY C H AR G E R M O D E L : P P - L B C - 1 2 2 0 V E R S I O N : V 1. 0 Contents 1. Revised History... 1 2. Warning... 1 3. Notes... 1 4. Product Number System...

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS RELIABLE SOLUTIONS in POWER ELECTRONICS Power Management Instruments DC Battery Charger / Automation Type Distributed by : nonstopower sdn bhd (822490-P) no. 78 & 80, jalan rimbunan raya, laman rimbunan,

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

.3 Section Waste Management and Disposal.

.3 Section Waste Management and Disposal. Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section

More information

Industrial Chargers and

Industrial Chargers and Industrial Chargers and DC Systems SPR - Single Phase Rectifier TPR - Three Phase Rectifier 12V 250V 5A 1000A Designed for all Industrial applications Oil & Gas, Petrochemicals Offshore, Onshore, Pipelines

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

SECTION DC POWER SUPPLY/BATTERY CHARGER

SECTION DC POWER SUPPLY/BATTERY CHARGER SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance

More information

Technical Specification SENTINEL PRO

Technical Specification SENTINEL PRO Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

ORION PLUS three-phase kVA

ORION PLUS three-phase kVA ORION PLUS three-phase 30-1250kVA Orion Plus stabilizers are available for different ranges of input voltage fluctuation. In the ±15%/ ±20% and ±25%/ ±30% types, the change of input range is obtained through

More information

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5

More information

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema

More information

PRODUCT CATALOGUE 2016

PRODUCT CATALOGUE 2016 PRODUCT CATALOGUE 2016 Static digital voltage stabilisers The static stabiliser is used when the correction speed represents the critical issue (for example, computers, laboratory equipment, measuring

More information

Switching Power Supplies

Switching Power Supplies , 18 150 Watt Features Compact boxed power supplies with screw terminal block Universal input 85-264 VAC, 50/60 Hz Short circuit and overvoltage protection High efficiency International safety approvals

More information

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00 INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR469100 BR25AT REV00 I CONTENT: 1 SAFETY 1.1 Safety instructions 1 1.2 Specified applications 1 1.3 Safety notes on the equipment operation 1 2 BR 25

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C C Mobile Communications 13 AMPERE POWER SUPPLY 19A704647P1-P3 CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER

More information

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility

More information

QUEENSLAND URBAN UTILITIES

QUEENSLAND URBAN UTILITIES DOCUMENT NO : EQUIPMENT NO : PREPRED : CHECKED : PPROVED : SHEET NO : 1 of 6 GENERL 1 Battery Charger DCC Inverters 3 DCDC Converters 4 System Design Life (other than batteries) Years 5 Battery Design

More information

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema

More information

ABB central inverters PVS to 2091 kva

ABB central inverters PVS to 2091 kva SOLAR INVERTERS ABB central inverters PVS980 1818 to 2091 kva 01 ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators

More information

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title High Voltage and 1500 System Earthing References and Definitions Reference Number PDS 02 (RIC Standard: EP 12 00 00 01 SP) Document Control

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES RELIABLE SOLUTIONS in POWER ELECTRONICS RDAT SERIES Power Management Instruments BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES BATTERY CHARGER / DC RECTIFIER RDA / RDAT AUTOMATION

More information

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual DC AC POWER INVERTER LIV 10 / LIV 20 / LIV 30 User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the Power Inverter. This

More information

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector Catalogue March 2015 InLine II - ZLBM/ZHBM Fuse Switch Disconnector 2 1SEC312022B0202 ABB Catalogue Contents Introduction 1 Apparatus 2 Accessories 3 Technical Data 4 Cable terminations and cable shrouds

More information

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL 72-7570 DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL Table of Contents Specification 1 Safety 3 EMC 4 Installation 5 Connections 5 Operation 6 Maintenance 8 Specification General specifications

More information

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1 BellMega BM-510 Operation Manual Ver: 1.0 Rev: 1 CONTENTS Page Description 1 Operation 2 Safety 2 Charging 3 Service / Calibration 3 Specifications 4 Description The BellMega is a continuity tester for

More information

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems An additional function allows measuring residual currents in earthed power supplies (TN/TT systems) too.

More information

INDUSTRIAL POWER SUPPLIES SFL-SERIES

INDUSTRIAL POWER SUPPLIES SFL-SERIES INDUSTRIAL POWER SUPPLIES SFL-SERIES Operating Instructions 1. Application The SFL-series are compact, rugged switching power supplies designed for applications in process automation and other industrial

More information

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators,

More information

Power Supplies. SDN-C Compact DIN Rail Series

Power Supplies. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high effi ciency and compact size with new visual diagnostic LEDs

More information

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT Maintenance Manual SCCP-WH-B4-en-20 98-4046720 Version 2.0 EN SMA Solar Technology

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

Industrial Power Supplies

Industrial Power Supplies , Features Switch Mode Power Supplies for DIN-rail Mounting 6 Power Ranges with 2, 3, 6, 12, 20 and 24 A Current (24 VDC Models) Selectable 115/ 230 VAC Input Very low Ripple and Noise EMI complies with

More information

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc. POWER SUPPLY MODEL XP-800 TWO AC VARIABLE VOLTAGES; 0-120V and 0-40V @ 7A, PLUS 0-28VDC @ UP TO 10A Instruction Manual Elenco Electronics, Inc. Copyright 1991 Elenco Electronics, Inc. Revised 2002 REV-I

More information

S&S POWER SWITCHGEAR EQUIPMENT LTD.,

S&S POWER SWITCHGEAR EQUIPMENT LTD., S&S POWER SWITCHGEAR EQUIPMENT LTD., Works: No.4, EVR Street, Sederapet, Puducherry 605 111, India. Corporate Office: Plot No:14, CMDA Industrial Area-II, Chithamanur Village, Maraimalai Nagar-603209,

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

PURE SINE WAVE DC TO AC POWER INVERTER

PURE SINE WAVE DC TO AC POWER INVERTER PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series

More information

Features. Description. Table of Contents

Features. Description. Table of Contents Features Very low profile Very high efficiency (typically 90%) Single and dual output versions Input voltages from 24V to 110VDC nominal voltages from 5V to 48VDC -40 C to +71 C operation without de-rating

More information

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low

More information

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS Power Quality Solutions 2018 POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS ACTIVE Ematic FA40 New Series ICAR: products and solutions Founded in 1946, ICAR is a leading manufacturer of capacitors and

More information

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist INTER PLANT STANDARD - STEEL INDUSTRY IPSS THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS Corresponding IS does not exist IPSS: 1-10-038-08 0 FOREWORD 0.1 This Inter Plant Standard has

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650523200 Ed.1 of 23/07/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and

More information

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION) INTER PLANT STANDARD STEEL INDUSTRY I P S S SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION) Corresponding IS does not exist IPSS: 1-10-036-12 0 FOREWORD 0.1 This

More information

POWERTRONIX QUASAR 5-40 KVA

POWERTRONIX QUASAR 5-40 KVA POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251

More information

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20 Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20 Maintenance Manual SC500-800HE20-WH-en-10 98-4110410 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...

More information

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/24DC/2 Order No.: 2866640 Uninterruptible power supply with integrated power supply unit, 2 A, in combination with MINI-BAT/24/DC 0.8 AH or 1.3 AH Commercial

More information

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible

More information

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection

More information

PIX-H Metal-clad switchgear up to 17.5kV

PIX-H Metal-clad switchgear up to 17.5kV AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...

More information

DART Charger Product Description, Information and Specification

DART Charger Product Description, Information and Specification g Digital Energy DART Charger Product Description, Information and Specification Document Number : PRPI-029 Version : 1.00 Revision : 2 Date : 03.02.11 Classification: NOTICE OF COPYRIGHT & PROPRIETARY

More information

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W Page 1 / 7 Full operation without need of battery Two independent 48Vdc outputs for switching and control Local monitoring with 8 LEDs Remote monitoring with 4 alarm relays Monitoring and configuration

More information

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA GTS-L / 0 / POWER SOLID STATE RELAYS WITH LOGIC CONTROL Main applications Extrusion lines and injection presses for plastics Hot channels Thermoforming machines Packing and packaging machines Temperature

More information

1. Electronic Stabilizer and Technical Development. 2. Electronic Stabilizer General

1. Electronic Stabilizer and Technical Development. 2. Electronic Stabilizer General SPW TPW6B series SCR Electronic Voltage Stabilizer/Power Conditioner for Industries Use Applications: Printing Specific /Medical Specific /Control Numerical Machine/Elevator Specific /Testing Specific/UPS

More information

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS Features Description The 4:1 Input Voltage 150 W single HEW Series of DC/DC converters provide precisely regulated dc outputs. The output voltage is fully isolated from the input, allowing the output to

More information

Offshore and process industry Safety and Automation Systems (SAS) Marine Communication systems onboard ships. Railway & Metro infrastructure

Offshore and process industry Safety and Automation Systems (SAS) Marine Communication systems onboard ships. Railway & Metro infrastructure POWER SUPPLY SYSTEMS FOR HIGHER PROTECTION CLASS Our power supply systems offer a protection class up to IP 55. Together with our Industrial building blocks it is suitable for a variety of applications,

More information

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices MEDIUM VOLTAGE PRODUCTS The worldʼs fastest switching devices 2 FAULT CURRENT LIMITERS THE WORLDʼ S FASTETST SWITCHING DEVICES The worldʼs fastest switching devices ABBʼs fault current limiters disconnect

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH

More information

8DJ. Maintenance-free for lifetime

8DJ. Maintenance-free for lifetime 8DJ Maintenance-free for lifetime Energy Distribution Welcome! Page 2 October 1 st 2008 8DJ Main Applications for Medium-Voltage Switchgear Power generation Power stations G Power transmission High and

More information

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism AMVAC Universal applications: Medium voltage motor starting applications Capacitor switching Retrofit applications to replace

More information

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW) Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv SF6 circuit breaker EDT with integrated current transformer ABB is a world leader in live tank circuit breaker

More information

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03 INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR469000 OR25 REV03 I II CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled BASIC FX 80 W Combined emergency lighting LED Driver Product description Fixed-output LED Driver for mains operation with integrated Simple CORRIDOR FUNCTION (CF) Emergency lighting LED Driver with manual

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual SEI 150/48-SEL-XXX DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email Info@seipower.com Web http://www.seipower.com

More information

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting

More information

ZX-Family Gas-insulated medium voltage switchgear

ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Minimum overall costs ZX offers maximum economy The compact design of the panels reduces the space required and therefore the size of the station. Freedom

More information

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications Outdoor live tank SF 6 circuit breaker Type OHB for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers

More information

Solar Inverter Manual

Solar Inverter Manual Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage

More information

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title Low Voltage Distribution and Installations Earthing References and Definitions Reference Number PDS 03 (ARTC Standard: EP 12 00 00 02 SP) Document

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

VSD Series II Variable Speed Micro Drives

VSD Series II Variable Speed Micro Drives VSD Series II Variable Speed Micro Drives Product Bulletin Code No. LIT-12011813 Issued March 26, 2013 Refer to the QuickLIT website for the most up-to-date version of this document. Johnson Controls VSD

More information

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Softstarters. Softstarters Type SSM Medium voltage ,800V 1 Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

Ag Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption

Ag Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption Datasheet Ag103 Intelligent Sealed Lead Acid Solar Battery Charger Module Pb 1 Features Multi-Stage Charging Solar Panel or DC Input Maximum Power Point Tracking (MPPT) Very Low Power Consumption Wide

More information

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies Data sheet Redundancy unit -A-RU Accessory for range power supplies ABB s redundancy units are used to establish true redundancy which increases the availability of electrical systems significantly. 2CDC

More information

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems Liebert Hipulse E The High-ECO-Availability UPS AC Power Systems We re Emerson Network Power, backed by Emerson, a global company that brings technology and engineering together to provide innovative solutions

More information

1.5KW DC-DC Converter Specification

1.5KW DC-DC Converter Specification 1.5KW DC-DC Converter Specification TDC-J Series V 3.2 Date 2016-10-14 1 Table of Contents 1 Overview 2 Basic functions 3 Technical Specifications 3.1 Product Naming 3.2 Model List 3.3 Model selection

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring ABB is a leader in power and automation technologies that enable utility and industry customers to

More information

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,

More information