Power Plants Industrial Machining and Assembly Chemical e Petrochemical Industries Civilian and Military Shipyards Off-shore Drilling Boiler-building

Size: px
Start display at page:

Download "Power Plants Industrial Machining and Assembly Chemical e Petrochemical Industries Civilian and Military Shipyards Off-shore Drilling Boiler-building"

Transcription

1 2015 GENERAL CATALOGUE

2 Power Plants Industrial Machining and Assembly Chemical e Petrochemical Industries Civilian and Military Shipyards Off-shore Drilling Boiler-building

3 My SICORT "When does the school year start?" "What kind of a question is this?!?! The school year starts on October 1st" "OK, it once used to be like that." "No, look, believe me: school year always starts on October 1st!!!" It's October 1st. I still have vivid memories of my anticipation for that day, the day that would have become a milestone in my life. The day I keep considering considering a milestone of my life. It is my first day in school. I am sitting at my desk. Ringing voices, distant laughs, footsteps in the corridor. The day has begun, the first day in school has begun. Silence. Everybody stands up. The choral "good morning" and then we are ready to start. start "II am opening my new exercise book". book This is how I feel everyday, as on my first day in school. And I felt exactly the same when, despite all of my insecurities, I took on the challenge of "opening S.I.CO.R.T. exercise book". boo A long diary full of success, along with some failures, that have been been stubbornly solved and turned into opportunities for growth. Today, well over thirty years later, I am not yet satisfied. satisfied When I wake up every morning to face a new day, I wonder: "What hat will I write on my S.I.CO.R.T. diary today?" and, exactly as it used to happen on my first day in school, school I leave home confident that I will do something good. good For myself and for my customers. customers

4 Post-weld /Pre-heat Treatment Units 7 Heat Treatment components 13 Cables and Connections 14 Heating Elements 16 Thermocouple Welding Units 21 Thermocouple and Accessories 22 Temperature Recorders 25 Connectors 26 Accessories 33 Thermal Insulation 34 Heating Elements Spares 35 Temperature Measurement Equipment 39

5 ... My Philosophy 5 The simplest thing to do would be filling our presentation with technology. We would rather like talking about us. Tell about our real evolution goes through the needs of our customers, our own needs and those of the products we are taking into consideration. Indeed there is no technology without the human, cultural and organisational evolution which our Firm has achieved. As a matter of fact, it is not our habit depending upon "technical facilities", rather the way they are used. For this reason we base our choices upon process analysis and organisation, in order to achieve an operational phase aligned with every desired feature. Whilst introducing our Heat Treatment units, we guarantee and certify each production step is constantly monitored by our system. The results of almost fifty years of experience translate into our new equipment for heat treatments and pipe welding process control.

6 BT and TL range is the right answer to all those who demand great operational versatility without huge management costs. All of our units undergo rigorous testing before delivery and every customer's expectation is thoroughly matched. The unit frames are studied to withstand uneven ground and the extreme conditions typical of construction sites. Besides, an anticorrosive treatment ensures high protection against adverse environment conditions.

7 ... Heat Treatment Units 7 Low-Tension Unit mod. ETTS-R6C (with built-in recorder) Low-Tension Unit mod. ETTS-R12C (with built-in recorders) Model Rating kva Output Channels Output (V) ETTS/50-R6C / ETTS/70-R6C / ETTS/100-R6C / ETTS/100-R12C /80 Pictured above are Low Tension heat treatment units. The unit performs pre-heating and subsequent heat treatment of welded joints (pipelines, tanks, oil tanks, fittings, adapters, elbows, etc ) of any kind and size. The use of such units stems from the following assessments: strains that may originate within a structure during welding may cause its breakage if not controlled. Pre-heating avoids the formation of critical crystalline structures by reducing the structure porosity. The following heat treatment eliminates all inner tensions deriving from the different cooling rate of contiguous structures. The frames of such units are manufactured in AISI 304 stainless steel. They are accurately finished, compactly built, easily transportable, reliable and longlasting even under heavy duty conditions. They are particularly suitable for use in workshops, industrial construction sites or shipyards. Fully automated functioning. Please, refer to S.I.CO.R.T. for technical features.

8 Low-Tension Unit mod. ETTS-R6 (without built-in recorders) Model Rating kva Output Channels Output (V) ETTS/50-R / ETTS/70-R / ETTS/100-R /80 Pictured above are Low Tension heat treatment units. The unit performs pre-heating and subsequent heat treatment of welded joints (pipelines, tanks, oil tanks, fittings, adapters, elbows, etc ) of any kind and size. The use of such units stems from the following assessments: strains that may originate within a structure during welding may cause its breakage if not controlled. Pre-heating avoids the formation of critical crystalline structures by reducing the structure porosity. The following heat treatment eliminates all inner tensions deriving from the different cooling rate of contiguous structures. The frames of such units are manufactured in AISI 304 stainless steel. They are accurately finished, compactly built, easily transportable, reliable and long-lasting even under heavy duty conditions. They are particularly suitable for use in workshops, industrial construction sites or shipyards. Fully automated functioning. Please, refer to S.I.CO.R.T. for technical features. Temperature Recorder mod. ET to match with ETTS-R6 Units Model Input Channels Characteristics ET 6-REC 6 Temp. Recorder Model Input Channels Characteristics ET 12-REC 12 Temp. Recorder ET 24-REC 24 Temp. Recorder

9 ... Heat Treatment Units 9 Low-Tension Unit mod. THERM BT6 Model Rating kva Output Channels Output (V) Therm 50 BT/ Therm 80 BT/ Therm 100 BT/ Pictured above are Low Tension heat treatment units. The unit performs pre-heating and subsequent heat treatment of welded joints (pipelines, tanks, oil tanks, fittings, adapters, elbows, etc ) of any kind and size. The use of such units stems from the following assessments: strains that may originate within a structure during welding may cause its breakage if not controlled. Pre-heating avoids the formation of critical crystalline structures by reducing the structure porosity. The following heat treatment eliminates all inner tensions deriving from the different cooling rate of contiguous structures. The frames of such units are manufactured of strong powder coated iron. They are accurately finished, compactly built, easily transportable, reliable and long-lasting even under heavy duty conditions. They are particularly suitable for use in workshops, industrial construction sites or shipyards. Fully automated functioning. Please, refer to S.I.CO.R.T. for technical features.

10 High Tension Units mod. TL Model Rating kva Output Channels Output (V) TL Main voltage heat treatment units. These main voltage units were designed for stress relieving heat treatments. Compact, lightweight, easy to handle and use. Suitable for tackling larger jobs, where other low voltage units and heater pads might prove uneconomic. Each unit output is protected by a differential switch and a MCB switch. Maximum power: 120 kva No.6, 19 kva each, independent outputs - Variable output voltage: 0 a 380Vac - Maximum output power: 50A - Standard supply: 380 Vac-50/60Hz (three-phase) - No.1 microprocessor programmer mod. G1800P - No.6 electronic temperature regulators mod. G No.1hybrid temperature recorder CHINO mod. BL160ENDN, 6 scalepoints 0-1,200 C - Data printout - Analogical/disp lay reading - Paper speed selectable range mm/h mm. paper pack- No.6 output voltage regulations 0-100% - Recorder extractable from front panel - Operating modes: manual/semiautomatic/automatic - Auto switch-off at the end of cycle - No.6 power units with thyristors type TH-1AX (400-60H) - No.1 60A Ammeter for each output - Input Voltmeter with RST switch - Portable design with handles - No.1 main MCB switch - No.6 63A MCB switches with 300mA fixed release- Emergency switch off - Door lock - No.6 outlets type Marechal 2P+T (IP64) with decontactor - Dimensions (mm): W 750 x H 600 x D Weight: 95 Kg. - Built in compliance with CEI safety regulations - User's Manual in English - CE marking. For further characteristics please, refer to S.I.CO.R.T.

11 ... Heat Treatment Units 11 Static Generator mod. SHG 40/80 Output Input Mod. kva V A KHz V A Hz Channel output SHG / SHG /60 1 S.I.CO.R.T. inverters or Static Generators, available in 40kWe 80kW power size, are designed for pre-heated welding and coating when an electric source is available. The digital control of the heating cycle and the control panel display allow easy access to the main parameters involved during the heating cycle such as electricity, voltage and output power. The output power can be adjusted and the duration of the heating cycle can be programmed. Options: heat treatment software, 6-channel temperature recorder. Please, refer to S.I.CO.R.T. for technical features.

12 The ET and EASYTHERM range is made up of portable units, reliable and easily transportable machines, which in smaller size offer the same technology and reliability of their "bigger sisters", powered by a welding machine. Temperature Control Regulator mod. ET Model Channel Input Characteristics ET 20-SR 1 Thermoregulator ET 20-PR 1 Programmer Temperature control - External power connection to DC welding machine - Adjustment through SCR diodes - No.1 control output for heating pads - Power supply: 50 to 80 Vcc - Maximum output power: 180A - No.1 programmable microprocessor thermoregulator - 2 x 3 digit display with 14 mm. green LEDs - K thermocouple input signal, C range, 0.5% f.s. accuracy - Load maximum power: 10.8 Kw - Service factor (200A): 80% - Automatic operating mode - No.2 balanced polarized outlets for K thermocouple inputs - Sizes (mm.): 220W x 230H x 380D - Weight: 9 Kg. - User's Manual in English - CE marking. Model Channel Input Characteristics ET 6-REC 6 Temp. Recorder Model Channel Input Characteristics ET 12-REC 12 Temp. Recorder ET 24-REC 24 Temp. Recorder Temperature Control mod. EASYTHERM P/n Model Channel Output Characteristics EASYTHERM 220 S 2 Thermoregulator EASYTHERM 220 P 2 Programmer External power connection to DC welding machine - No.2 independent outputs - Maximum voltage per output: 80V - Maximum power per output: 200A - No.2 microprocessor thermoregulators mod. G x 3 digit display with 14 mm. green LEDs - K thermocouple input signal, C range, 0.5% f.s. accu racy - Automatic operating mode (0-100%) - No.2 balanced polarized outlets for K thermocouple inputs - No.2 balanced polarized outlets for temp. recorder connection - No.1 24V auxiliary outlet - Service power supply: 220V-50Hz (other voltages upon request) - Sizes (mm.): 455W x 360H x 450D - Weight: 18 Kg. - Built in compliance with CEI safety regulations - CE marking.

13 ... Heat Treatment Components 13 A complete equipment range supporting heat treatment units, built with the best materials nowadays available on the market, designed to ensure the best results in your line of work. Immediate availability and constant supply of our warehouse, together with special agreements with express couriers, guarantee short delivery lead times.

14 Twin Cable Sets (Connection between power source and splitter cable) Models Size Length BT & ETTS 2 x 25 mm 2 30 m BT & ETTS 2 x 25 mm 2 15 m BT & ETTS 2 x 35 mm 2 30 m BT & ETTS 2 x 35 mm 2 15 m. Note: other sizes upon request Triple Cable Sets Length Dual insulated rubber set 16 mm 2 30 m Dual insulated rubber set 16 mm 2 15 m Dual insulated rubber set 25 mm 2 30 m Dual insulated rubber set 25 mm 2 15 m Dual insulated rubber set 35 mm 2 30 m Dual insulated rubber set 35 mm 2 15 m. Note: other sizes upon request Heater Pad Connecting Splitters Ways Heater Pad Connecting Splitters Ways

15 ... Cables and Connections 15 Heater Pad Connecting Splitters Ways Thermocouple Compensated Cables Length Colour (IEC584) m. Green m. Green m. Green m. Green m. Green Note: other sizes upon request

16 Flexible Ceramic Pads (all sizes in mm.) Voltage Size X Size Y Rating Kw UPON REQUEST: a) other Voltages (V) b) Hi-temp (up to 1,300 C) Kanthal D wire assembl y When ordering, please quote size "X" first.

17 ... Ceramic Pad Heaters 17 Tank Track Heaters (all sizes in mm.) Voltage Size X Size Y Rating Kw Tank Track Heaters (insulated pre-heaters, all sizes in mm.) Voltage Size X Size Y Rating Kw Ceramic Pad Heaters (insulated pre-heaters, all sizes in mm.) Voltage Size X Size Y Rating Kw

18 Ceramic Tape Heaters (all sizes in mm.) Voltage Size X Size Y Rating Kw Single Row Heaters (all sizes in mm.) Voltage Amps Length Rating Kw Note: other Voltage upon request Spreader Mats Voltage Amps Rating Kw Note: when ordering, please refer to the ceramic pad heater size table on pag. 16

19 ... Ceramic Pad Heaters 19 Stainless Steel Rope Heaters (all sizes in mm.) Voltage Length Rating Kw Stainless Steel Clamp-on Heaters inches (mm.) Voltage " " " " " " " " " " " " " " Note: other Voltage upon request

20 Stainless Steel Clamp-on Heaters) inches (mm.) Voltage " " " " " " " " " " " " " " Note: other Voltage upon request

21 ...Thermocouple Welding Units 21 Thermocouple Welding Units Type Rating Characteristics TW 55-J J For wire mm. Power supply: 95/230 Vac or car 12 Vac lighter socket. Type Rating TW 100-J J Characteristics For wire mm. Stainl. St. nails 2.0 mm. Power supply: 95/230 Vac or car 12 Vac lighter socket. Type Rating Characteristics SW 12V Power supply: 110/220 Vac Low: J High: J For wire mm. St.St. nails mm. Type Rating Characteristics TW J For wire mm. Power supply: 4 alkaline AA batteries * ) TW 55-J and TW 100-J Spare Parts Characteristics Rechargeable battery (12v - 3,2Ah) for TW55J & TW100J Pliers and magnet Rechargeable battery YUASA NP2 for TW113 *) For SW 12V spare parts, please, refer to S.I.CO.R.T.

22 Thermocouple Twisted Wire Type AWG Insulation Temp. Range K 20 (0.711 mm.) Fibreglass 705/870 C K 24 (0.508 mm.) Fibreglass 705/870 C K 20 (0.711 mm.) Ceramic Fibre 1205/1430 C Note: sold in 100 m. rolls Stainless Steel T/C MGO insulated thermocouple, INCONEL 600 sheath, ungrounded junction. Type Length (mm.) mm. Specifications K IEC K IEC K IEC K IEC 584 Note: standard lengths. Other lengths upon request. T/C Wire Twisted twin wire (20 AWG), with standard balanced male plug. Type Length (mm.) K AWG K AWG K AWG K AWG Note: standard lengths. Other lengths upon request. Stainless Steel T/C Welding Plate Size (mm.) Pipe (mm.) x 25 4,6

23 ... Thermocouples & Accessories 23 Compensating Cable Type Size Insulation Colour (IEC584) K 2 x 0.50 PVC/PVC Green K 2 x 0.80 PVC/PVC Green K 2 x 1.00 PVC/PVC Green K 2 x 1.30 PVC/PVC Green K 2 x 1.50 PVC/PVC Green Note: other colours upon request.

24 Thermocouple Plug Type K, Hollow Pin Type Colour (IEC584) ANSI K Green Yellow Thermocouple Socket Type K Type Colour (IEC584) ANSI K Green Yellow Panel Mounted Thermocouple Socket Type K Type Colour (IEC584) ANSI K Panel mounted Green Yellow Thermocouple Putty Packing size & shape gr. can

25 ... Temperature Recorders 25 CHINO Temperature Recorders (6/12/24 Channels) Mod. Range Inputs Paper Width KL ,200 C/K mm AL ,200 C/K mm AH ,200 C/K mm AH ,200 C/K mm. CHINO Paper Chart Type Range Paper Width EM ,200 C/linear 100 mm EM ,000 C/ linear 100 mm. Note: sold in 3-piece box Type Range Paper Width ET ,200 C/linear 180 mm ET ,000 C/ linear 180 mm. Note: sold in 3-piece box Type Ribbon Width KL/AL 100 mm KH/AH 180 mm. CHINO Recorder Printer Ribbon CHINO Recorder Front Panel Type KL AL KH AH

26 Complete Connectors (twistlock) Complete 60A Connector - male Complete 60A Connector - female Complete 300A Connector - male Complete 300A Connector - female

27 ... Connectors 27 Complete Connectors (panel mounted) A Male Twistlock A Female Twistlock A Male Twistlock A Female Twistlock

28 Connector Spare Parts A Male Insulated Sleeve A Female Insulated Sleeve Connector Spare Parts A Male Fibreglass Sleeve A Female Fibreglass Sleeve

29 ... Connectors 29 Connector Spare Parts A Brass Twistlock Plug A Brass Twistlock Socket Connector Spare Parts A Sleeve Locking Pin

30 Connector Spare Parts A Male Insulated Sleeve A Female Insulated Sleeve Connector Spare Parts A Male Fibreglass Sleeve A Female Fibreglass Sleeve

31 ... Connectors 31 Connector Spare Parts A Brass Twistlock Plug A Brass Twistlock Socket Connector Spare Parts A Sleeve Locking Pin

32 ... Welding (DINSE) Connectors Complete Connectors Welding (DINSE) Plug Welding (DINSE) Socket Panel-Mounted Complete Connectors Panel-Mounted DINSE Socket

33 ... Accessories 33 Band Stainless Steel Band AISI 201, ½", 30 m. Lenght Banding Tool Banding Tool (BAND-IT) Buckles AISI 201 Buckles, ½", 100 piece box Stainless Steel Nails ISO S/S Nail, 2.1 x 30 mm. 1,000 piece box ISO S/S Nail, 2.1 x 50 mm. 1,000 piece box ISO S/S Nail, 2.6 x 30 mm. 1,000 piece box ISO S/S Nail, 2.6 x 50 mm. 1,000 piece box ISO S/S Nail, 2.6 x 80 mm. 1,000 piece box Clips ISO IC Copper Clip, 2.6mm. 1,000 piece box Clip FE 38 x 1.8 mm., 1,000 piece box

34 ... Thermal Insulation Ceramic Fibre Insulation Roll Thickness Density Width mm. 96 kg. /m 3 7,320 x 610 mm mm. 128 kg. /m 3 7,320 x 610 mm mm. 128 kg. /m 3 3,660 x 610 mm. Ceramic Fibre Mats Thickness Density Width mm. 128 kg. /m x 300 mm. 1,100 C mm. 128 kg. /m x 300 mm. 1,100 C mm. 128 kg. /m x 300 mm. 1,100 C mm. 128 kg. /m x 600 mm. 1,100 C mm. 128 kg. /m x 600 mm. 1,100 C mm. 128 kg. /m 3 1,200 x 600 mm. 1,100 C mm. 128 kg. /m 3 1,800 x 600 mm. 1,100 C mm. 128 kg. /m 3 3,600 x 600 mm. 1,100 C mm. 128 kg. /m 3 7,200 x 600 mm. 1,100 C Ceramic fibre mats may be encased with stainless steel mesh or VT ceramic cloth. Stainless Steel Mesh Roll Length / kg. Width mm mm.

35 ... Ceramic Pad Spare Beads 35 Ceramic Heater Insulator Elements Type Box Main Body Bead 500 pcs. Type Box Main Body Bead with fixing hole 500 pcs. Type Box Male End Bead 500 pcs. Type Box Female End Bead 500 pcs.

36 Ceramic Heater Insulator Elements Type Box Tail Bead - Pink 250 pcs Tail Bead - White 250 pcs. Type Box Tail Junction Bead 42.0 x 9.5 mm. internal 100 pcs. Type Box Tail Junction Bead 29.0 x 7.75 mm. internal 100 pcs. Type Box Tail Junction Bead 31.8 x 7.4 mm. internal 100 pcs.

37 ... Ceramic Pad Spare Beads 37 Ceramic Heater Insulator Elements Type Box Olive-shaped 100 pcs. Type Box Tank Track Main Bead 10 pcs. Type Box Split Bead for repairs, with Forelocks 100 pcs. Type Box Male End Bead with fixing hole 100 pcs Female End Bead with fixing hole 100 pcs.

38 Bulk Strand Wire Type Composed of Nickel/Chromium 60/16 19 strand Nickel/Chromium 80/20 19 strand Nickel strand Nickel/Chromium 80/20 37 strand Kanthal D (up to 1,300 C) 19 strand Note: sold in 500 m. rolls. Heater Core Wire with Cold Tails Type Volts Ni/Cr 60/16 wire, with Nickel 212 cold tail wire Ni/Cr 60/16 wire, with Nickel 212 cold tail wire 80 Welding Ferrule Box pcs. Securing Magnets (pre-heaters) Type Coupled Rectangular Magnets

39 ... Temperature Measurement Equipment 39 A range of highly efficient instruments were selected by our research centre. With S.I.CO.R.T. tools each control becomes easy with reliable results. Our wide selection range allows several choices, suitable to every need. S.I.CO.R.T. instruments are covered by worldwide warranty.

40 VA18B Digital Multimeter PC connection via USB port Temperature Testing Diode Testing/Buzzer Electronic Protection System Type Digital Multimeter VA18B VA710 Thermocouple Calibrator For J, K, T, E, R, S, B, N thermocouples (Standard NIST 175) Thermocouple measuring and simulation, temperature range: -250 ~ 1,800 C Temperature Resolution: J, K, T, E, R, S, B, N (0.3 C) Temperature Error: J, K, T, E, R, S, B, N ± (0.3 C + 10 µv) Range: (V) -10 mv ~ 75 mv Resolution: 0.01 mv Accuracy: ± (0.025% + 1 count) Temperature Range: ITS 90 Power Supply: 1.5V (6 x AAA) Auto Switch Off Type Thermocouple Calibrator VA710 VA318 Digital Clamp Meter Type Digital Clamp Meter VA318

41 ... Temperature Measurement Equipment 41 VA21 Digital Multimeter Type Digital Multimeter VA21 K type Thermocouple input Measurement range: - 50 C ~ 750 C Resolution: +/- 1 C Power: 9V (1 x 6F22) Size: x 72 x 27 mm. Weight: 145 g. (including batteries) Accessory: thermocouple probe VA3408 MS6500 Thermometer Type Mini-thermometer MS6500 VA6533 Infrared Thermometer Measurement range: - 20 C ~ 50 C ± 2.5 C / 50 C ~ 537 C ± (reading 1% + 1 C) Emissivity: 0.95 Resolution: 0.3 C Average distance to target: 12:1 LCD Display: 2 temperatures, 4 digits Laser power: less than 1 mw Type Infrared Thermometer VA6533 Measurement range: - 20 C ~ 50 C Accuracy: 20 C ~ 0 C ± (reading 1.5% ± 3.0 C) Resolution: 1 C Temperature reading top distance: up to 1 m. Auto Switch Off: 30s VA6510 Mini-Infrared Thermometer Tipo Mini-Infrared Thermometer VA6510

42

43 ... Notes 43

44 Via Provinciale, 268/b Loc. Castione Marchesi Fidenza (PR) Tel.: Fax: S.I.CO.R.T. S.r.l. - Castione Marchesi - Fidenza (PR) - Italy All right reserved, including translations. Total or partial reproduction of this catalogue can only be made under written permission by S.I.CO.R.T. S.r.l. Part of the technology described in this catalogue is patented. La S.I.CO.R.T. S.r.l., whose policy is to continously improve its products, reserves the right to discontinue or change specifications, models or design without previous notice and/or without incurring any obligation. Published and printed in Italy by S.I.CO.R.T S.r.l.

product catalogue W: E:

product catalogue W:   E: product catalogue W: www.artechservices.co.uk E: sales@artechservices.co.uk welcome to artech services With almost four decades and three generations of experience in the industry, Artech Services Ltd

More information

PRE-HEAT & POST WELD HEAT TREATMENT EQUIPMENT & ACCESSORIES

PRE-HEAT & POST WELD HEAT TREATMENT EQUIPMENT & ACCESSORIES PRE-HEAT & POST WELD HEAT TREATMENT EQUIPMENT & ACCESSORIES STATE OF THE ART TECHNOLOGY MARITIME STRESS IS COMMITTED TO PROVIDING HIGH QUALITY PRODUCTS AT COMPETITIVE PRICES. Page 2 Since the establishment

More information

HEAT TREATMENT EQUIPMENT & ACCESSORIES

HEAT TREATMENT EQUIPMENT & ACCESSORIES HEAT TREATMENT EQUIPMENT & ACCESSORIES Dear Customer, ElectroHeat Sweden AB is an innovative company based in Gothenburg, Sweden, and has been operating since 1975. We manufacture industrial furnaces and

More information

STRESSTECH CAPABILITIES

STRESSTECH CAPABILITIES STRESSTECH CAPABILITIES M A C T E C H H E A T T R E A T I N G S O L U T I O N S HEAT TREATING A Division of Mactech STRESS RELIEVING CONSOLES STRESSTECH manufactures three portable stress relieving consoles

More information

B BASIC HEAT TREATMENT CONSOLE

B BASIC HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

Cable thermocouple Model TC40

Cable thermocouple Model TC40 Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 for further approvals see page 11 Applications For direct installation into the process Machine building Motors

More information

HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2

HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2 HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2 Batteries 4 1.5V type AA batteries Autonomy 200 hours with 1800mAh alkaline batteries Power absorbed with instrument off 20μA Mains models HD2114P.2 and HD2134P.2

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE

More information

Mineral Insulated Resistance Thermometers (RTD)

Mineral Insulated Resistance Thermometers (RTD) Mineral Insulated Resistance Thermometers (RTD) Electronic Temperature Measurement Data sheet : MIRTD/2012 Contents Page RTD Element Type 2 Conductors & Number of Wires 2 Probe Diameter 3 Length Types

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

OPERATION MANUAL. TZ Two Zone Controller

OPERATION MANUAL. TZ Two Zone Controller Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB Electrical temperature measurement For the plastics machinery industry Fixed bayonet Model TC47-FB WIKA data sheet TE 67.24 Applications Plastics and rubber industry For direct installation into the process

More information

fax

fax INDUSTRIAL THERMOMETERS Industrial thermometers Selecting the correct thermometer for an application is by definition very important, to achieve the maximum accuracy and repeatability of the temperature

More information

COOPERHEAT LEADING INNOVATORS IN THERMAL TECHNOLOGY

COOPERHEAT LEADING INNOVATORS IN THERMAL TECHNOLOGY COOPERHEAT EQUIPMENT LEADING INNOVATORS IN THERMAL TECHNOLOGY consumables, spares & accessories catalogue introduction 02 03 10 12 14 16 18 23 introduction spares consumables cables accessories insulation

More information

T-REX T-REX INCREMENTAL EXTENSOMETER SETTLEMENT GAUGES

T-REX T-REX INCREMENTAL EXTENSOMETER SETTLEMENT GAUGES _ T-REX INCREMENTAL EXTENSOMETER SETTLEMENT GAUGES T-REX INCREMENTAL EXTENSOMETER SISGEO designed the T-REX incremental extensometer to measure the position of magnetic rings set along the axis of inclinometer

More information

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB Electrical temperature measurement For the plastics machinery industry Adjustable bayonet Model TC47-AB WIKA data sheet TE 67.20 Applications Plastics and rubber industry For direct installation into the

More information

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument 7526A Precision Process Calibrator Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument The 7526A Precision Process Calibrator calibrates a wide range of pressure

More information

For the plastics machinery industry Manifold thermocouple Model TC47-MT

For the plastics machinery industry Manifold thermocouple Model TC47-MT Electrical temperature measurement For the plastics machinery industry Manifold Model TC47-MT WIKA data sheet TE 67.21 Applications Plastics and rubber industry Hot runner manifolds for injection mould

More information

RS MODEL 2030

RS MODEL 2030 RS375-2798 MODEL 2030 THERMOCOUPLE THERMOMETER / SIMULATOR FEATURES A high accuracy instrument that will give you confidence in your other instruments. The simulator was designed to simulate a known temperature

More information

Hot Runner Thermocouples Model TC46

Hot Runner Thermocouples Model TC46 Electrical Temperature Measurement Hot Runner Thermocouples Model TC46 WIKA Data Sheet TE 65.46 Applications Plastics and rubber industry Hot Runner bushings, drops and nozzles Hot Runner manifolds Moulds

More information

Electronic Monitoring Systems

Electronic Monitoring Systems JJ Electronic digital thermometer JJ Multi-channel temperature indicator JJ Temperature sensors JJ KombiTemp Electronic Monitoring Systems and Temperature Sensors DS_Electronic_monitoring_systems_and_temperature_sensors

More information

Thermocouple insert for Temperatur Sensor omniset- TPC 100

Thermocouple insert for Temperatur Sensor omniset- TPC 100 Technical Information TI 278T/02/en 60022421 Thermocouple insert for Temperatur Sensor omniset TPC 100 Thermocouple mineral insulated insert PCP (4...20 ma), HART or PROFIBUSPA electronics The TPC 100

More information

MMC RTX series EN3716

MMC RTX series EN3716 MMC RTX series EN3716 7 CONTENTS Page Introduction... 7-4 Application 7-4 Features... 7-4 Product overview... 7-5 Electrical characteristics... 7-6 Mechanical & environmental characteristics... 7-6 Products

More information

C07 - Probes. Sonde EN Pg.01/ E.M.P. Srl -ITALY -

C07 - Probes. Sonde EN Pg.01/ E.M.P. Srl -ITALY - C07 - Probes Sonde EN Pg.01/12 2011-01 E.M.P. Srl -ITALY - www.emp.it C07 - Probes S MgO Insulation S100851000J J insulated 1,0 80 1000 S101051000J J insulated 1,0 100 1000 S102051000J J insulated 1,0

More information

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Pressure transmitters for heavy duty applications MBS 3200 and 3250 Data sheet Pressure transmitters for heavy duty applications MBS 3200 and 3250 The compact high temperature pressure transmitter MBS 3200 is designed for use in hydraulic and almost all industrial applications,

More information

THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES

THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES ABOUT LABFACILITY Formed in 1971, Labfacility specialises in the field of Temperature and Process Measurement. We are the largest UK manufacturer of both

More information

Thermocouple Model TC10-E, for additional thermowell

Thermocouple Model TC10-E, for additional thermowell Electrical temperature measurement Thermocouple Model TC10-E, for additional thermowell WIKA data sheet TE 65.05 Applications Chemical industry Petrochemical industry Offshore Machine building, plant and

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 11 Applications For direct installation into the process Machine building

More information

Cable thermocouple Model TC40

Cable thermocouple Model TC40 Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 Applications For direct installation into the process Machine building Motors Bearings Pipelines and vessels Special

More information

LIST OF CONTENTS TESTING EQUIPMENT

LIST OF CONTENTS TESTING EQUIPMENT LIST OF CONTENTS TESTING EQUIPMENT Batterytester BBT 305 Batterytester BBT 605 Batterytester BT 301 Batterytester Milton Batterytester Milton Digital Batterytester 500 A2 Forrex tester 12V 420A HSP Printer

More information

Harris IRT Enterprises Digital Resistance Tester Model XP

Harris IRT Enterprises Digital Resistance Tester Model XP Harris IRT Enterprises Digital Resistance Tester Model 5012-06XP Specifications & Dimensions 2 Theory of Operation 3 Operator Controls & Connectors 4 Test Connections 5 Calibration Procedure 6-7 Options

More information

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments Time Electronics Calibration, Test and Measurement Portable Process and Pressure Calibration Instruments Calibrators Simulators Sources Pumps Gauges www.timeelectronics.com Loop & Temperature Calibration

More information

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations DLRO 10 and DLRO 10X DESCRIPTION NEW interchangeable test lead terminations Auto current reversal cancels standing emfs Protected to 600 V Automatically detects continuity in potential and current connections

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

Installation Instructions for: Channel Thermocouple Amplifier

Installation Instructions for: Channel Thermocouple Amplifier Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier WARNING: This installation is not fo r the electrically or mechanically challenged! Use this sensor with EXTREME caution! If you

More information

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface fluid technology temperature sensors 1600 1 dimensions Ø38 x 118mm temperature operating range -40 to +300 C temperature measuring range from -40 to +300 C M12 socket for PT100 resistance thermometer analog

More information

INSTALLATION RULES for SCS/SENSOR Pt100

INSTALLATION RULES for SCS/SENSOR Pt100 INSTALLATION RULES for SCS/SENSOR Pt100 1MN0118 REV. 0 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it

More information

UNIVERSAL CALIBRATOR M

UNIVERSAL CALIBRATOR M INTRODUCTION UNIVERSAL CALIBRATOR - 3001M Before going through the instruction manual for actual use of the instrument go through the specifications and take note of the following points carefully 1. No

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

Surface thermocouple Model TC50

Surface thermocouple Model TC50 Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial

More information

Thermocouples Model TC10-E, for Additional Thermowell

Thermocouples Model TC10-E, for Additional Thermowell Electrical Temperature Measurement Thermocouples Model TC10-E, for Additional Thermowell WIKA Data Sheet TE 65.05 Applications Chemical industry Petrochemical industry Off-Shore Machine building, plant

More information

Products for. Section

Products for. Section 2 Products for Section Chemical Industries Grain silos Oil and Gas industry Plastics Fertilisers and insecticides Wood Cosmetics and perfumes lcohol and spirits Pharmaceutical Industries, etc. 90 2005-2006

More information

Pressure transmitters for heavy duty applications Type MBS 3250

Pressure transmitters for heavy duty applications Type MBS 3250 Pressure transmitters for heavy duty applications Type MBS 3250 Features Designed for use in harsh industrial environments For medium and ambient temperatures up to 125 C With integrated pulse-snubber.

More information

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE TRANSDUCERS. Specifications. Individual Specifications 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need

More information

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU) INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU) Model Number: 41756 (100 125Vac) 41757 (220 240Vac) Manufactured in the United Kingdom CONTENTS Chapter Page Specification 3 What the TAU does

More information

Hot runner thermocouple Model TC46

Hot runner thermocouple Model TC46 Electrical temperature measurement Hot runner thermocouple Model TC46 WIKA data sheet TE 65.46 for further approvals see page 7 Applications Plastics and rubber industry Hot runner bushings, drops and

More information

PROVA 1011 Solar System Analyzer

PROVA 1011 Solar System Analyzer PROVA 1011 Solar System Analyzer CE CAT II 1000V, CAT III 300V Features: I-V curve test for solar system. Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability). The analyzer

More information

MOBILE MEASUREMENT TECHNOLOGY

MOBILE MEASUREMENT TECHNOLOGY WWW.CSM.DE WWW.SAB-WORLDWIDE.COM MOBILE MEASUREMENT TECHNOLOGY FOR HV COMPONENTS Also for AD and Pt measurement modules! CONTENT The companies S BRÖCKSKES GmbH & Co. KG und CSM GmbH - Computer-Systeme-Messtechnik........

More information

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050 Data sheet Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050 The compact pressure transmitter, type MBS 3000, is designed for use in almost all industrial applications, and offers

More information

Using your Digital Multimeter

Using your Digital Multimeter Using your Digital Multimeter The multimeter is a precision instrument and must be used correctly. The rotary switch should not be turned unnecessarily. To measure Volts, Milliamps or resistance, the black

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications $ PROGRAMMABLE POWER SUPPLY EAN CODE : 3760244880062 1 output Powerfull POWERFUL ALR3220 VISUAL : Large graphic display SOFT-TOUCH : Sensitiv keypad CONNECTED : USB, RS232, RS485 & 0-10V isolated LabVIEW

More information

Short Form Catalogue AJ Thermosensors

Short Form Catalogue AJ Thermosensors Thermocouples Short Form Catalogue AJ Thermosensors Resistance thermometers Head mounted Probe style Application specific Accessories See the individual datasheets for more detailed information on each

More information

Operating Instructions TF04

Operating Instructions TF04 10 Brent Drive Hudson, MA 01749 Tel: +1-978-212-0006 Fax: +1-978-568-0060 Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating Instructions TF04 Temperature

More information

AKM 345 Gen2. Instruction Manual. Oil Temperature Indicator AKM OTI Type 34 Winding Temperature Indicator AKM WTI Type 35. Document ID: IST EN

AKM 345 Gen2. Instruction Manual. Oil Temperature Indicator AKM OTI Type 34 Winding Temperature Indicator AKM WTI Type 35. Document ID: IST EN Instruction Manual AKM 345 Gen2 Oil Temperature Indicator AKM OTI Type 34 Winding Temperature Indicator AKM WTI Type 35 Document ID: IST-103-1-EN www.qualitrolcorp.com (IST-103-1-EN) Legal Information

More information

Ritmo meets all your welding needs in your jobsite

Ritmo meets all your welding needs in your jobsite Ritmo meets all your welding needs in your jobsite The information and photos in this publication are not binding and RITMO S.P.A. is free to make any alterations without prior notice. A RITMO DVANTAGE

More information

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region)

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Linking the Future As the worldwide leader

More information

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050 MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050 The compact pressure transmitter, type MBS 3000, is designed for use in almost all

More information

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250 Data sheet High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250 The compact heavy duty pressure transmitter type MBS 2200 and MBS 2250 are designed for use in severe

More information

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE TRANSDUCERS. Specifications. Individual Specifications GEMS COMPLIANT 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 00 psi to 0-0,000 psi ranges (0- bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For

More information

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)... Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG

More information

DC disconnect. #4 AWG Negative wire

DC disconnect. #4 AWG Negative wire 90 ASSEMBLING A SOLAR GENERATOR Figure 11-3: Inverter Input Circuit DC disconnect #4 AWG Positive wire 75 amp fuse 12-volt deep cycle battery, 120 Ah 400 watt Inverter #4 AWG Negative wire So we should

More information

Safety technology/equipment

Safety technology/equipment Safety technology/equipment Reliable electronic and electro-mechanical products according to DIN EN 14597 Contact Phone: +49 661 6003-727 Email: automation@jumo.net Dear Readers, Safety and reliability

More information

TOTALIFT TL-Series Industrial Battery Charger

TOTALIFT TL-Series Industrial Battery Charger TOTALIFT TL-Series Industrial Battery Charger The TOTALIFT TL-series charger can be used with batteries of any type, voltage and capacity, at almost any temperature. The output voltage and current normally

More information

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250 Data sheet Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250 MBS 8200 is a series of compact pressure transmitters developed to withstand the pressure pulsations and vibrations known

More information

Temperature multi-function calibrator Model CTM

Temperature multi-function calibrator Model CTM Calibration Temperature multi-function calibrator Model CTM9100-150 WIKA data sheet CT 41.40 for further approvals see page 3 Applications Testing and calibration of all types of temperature measuring

More information

High temperature sensors

High temperature sensors Certificata IO 92 EI s.r.l. - via Milano, 11-22 ainate (MI) Tel.: (2) 937868 / 937342 - Fax: (2) 9371724 Home page: www.elsi.it e-mail: info@elsi.it High temperature traight thermocouple M1 with ceramic,

More information

Basic Kiln Repair Seminar - Topics. Basic Kiln Repair Seminar - Kiln Components. Basic Kiln Repair Seminar - Available Power

Basic Kiln Repair Seminar - Topics. Basic Kiln Repair Seminar - Kiln Components. Basic Kiln Repair Seminar - Available Power Topics Kiln Components Kiln Components Available Power Cord Sets, Plugs, Receptacles Electrical Controllers Thermocouples Temperature Profiles Test Equipment Wiring Diagrams Practical Troubleshooting Digital

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

WIRE ROPE HOISTS & TROLLEYS. XM Series MISIA HOISTS & LIFTING SOLUTIONS

WIRE ROPE HOISTS & TROLLEYS. XM Series MISIA HOISTS & LIFTING SOLUTIONS WIRE ROPE HOISTS & TROLLEYS XM Series MISIA HOISTS & LIFTING SOLUTIONS INDEX MISIA THE COMPANY 2 QUALITY AND CERTIFICATIONS 4 MISIA WIRE ROPE HOISTS XM SERIES 6 Standard configurations 8 Components 10

More information

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console.

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console. SP4 DOCUMENTATION 1. SP4 Reference manual.... 1 1.1. SP4 console... 1 1.2 Configuration... 3 1.3 SP4 I/O module.... 6 2. Dynamometer Installation... 7 2.1. Installation parts.... 8 2.2. Connectors and

More information

- Quicktemp TP62/TW39...T500 -

- Quicktemp TP62/TW39...T500 - Das modulare MODULAR von Hengesbach 2x transmitters TE42 each with 4...20mA, 2-L Redundant temperature measurement in heating lines, for example FEATURES 1 BASIC DEVICE - PROCESS ADAPTATION USING PROTECTIVE

More information

Probe Type Accuracy Handle Shaft Cable Plug Model Surface Probes Max. temp. at tip 7 sec. 220 C 428 F Response time

Probe Type Accuracy Handle Shaft Cable Plug Model Surface Probes Max. temp. at tip 7 sec. 220 C 428 F Response time Probe Type Accuracy Handle Shaft Cable Plug Technical data probes type K : K type thermocouple : Class I Premium grade : ABS, 110 mm long, 90 C max. : Stainless steel : 1000 mm standard. Coiled polyurethan

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

Modular resistance thermometer - Quicktemp TP60/TW39...T500 -

Modular resistance thermometer - Quicktemp TP60/TW39...T500 - Das modulare MODULAR von Hengesbach QUICK-CALIBRATE INSIDE FEATURES 1 BASIC DEVICE - PROCESS ADAPTATION USING PROTECTIVE SLEEVE DESIGNS QUICKTEMP MODULAR PROCESS CONNECTION SYSTEM FOR DEVICE REPLACEMENT

More information

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used

More information

Nozzle band heaters MODEL Z.11 (BRASS) MODEL Z.15 (STEEL) MODEL Z.17 (STEEL/PLUS) MODEL Z.19 (STEEL) MODEL Z.20 (CERAMIC) MODEL Z.

Nozzle band heaters MODEL Z.11 (BRASS) MODEL Z.15 (STEEL) MODEL Z.17 (STEEL/PLUS) MODEL Z.19 (STEEL) MODEL Z.20 (CERAMIC) MODEL Z. ... Infinite solutions... Nozzle band heaters MODEL Z.11 (BRASS) MODEL Z.15 (STEEL) MODEL Z.17 (STEEL/PLUS) MODEL Z.19 (STEEL) MODEL Z.20 (CERAMIC) MODEL Z.122 (MAXI) Index 2 4 6 9 11 13 15 19 Model Z.11

More information

InoxSabiana 50 Flues Stainless Steel Double Wall ENVIRONMENTAL COMFORT

InoxSabiana 50 Flues Stainless Steel Double Wall ENVIRONMENTAL COMFORT Flues Stainless Steel Double Wall ISO 9001 - Cert. n 0545/4 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONMENTAL COMFORT Introduction and main constructional characteristics Double

More information

HUMIDITY / TEMPERATURE TRANSMITTER

HUMIDITY / TEMPERATURE TRANSMITTER HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY

More information

EMISSIONS Analysis.

EMISSIONS Analysis. EMISSIONS Analysis www.texa.com 2 FUTURE-PROOF SOLUTIONS FOR PTI CENTER Exhaust gas analysis is one of the most delicate and important phases in the mandatory testing of old and new motor vehicles. In

More information

Thermocouple Model TC10-H without thermowell

Thermocouple Model TC10-H without thermowell Electrical temperature measurement Thermocouple Model TC10-H without thermowell WIKA data sheet TE 65.08 for further approvals see page 7 Applications For direct installation in the process Machine building

More information

Weld Preheating and Stress Relieving. Process. Induction Heating. Input Power VAC, 3-Phase, 60 Hz

Weld Preheating and Stress Relieving. Process. Induction Heating. Input Power VAC, 3-Phase, 60 Hz ProHeat 35 Weld Preheating and Stress Relieving Issued July 2005 Index No. IN/11.0 Induction Heating System Quick Specs Applications Maintenance Construction Transmission Pipeline Power Piping Petrochemical

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 further approvals see page 11 Applications For direct installation into the process Machine building

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building

More information

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths

More information

Autoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69)

Autoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69) Autoclave Thermocouples (Type 9) and Pt100 Sensors (Type 69) A range of thermocouple sensors specifically designed to withstand the harsh conditions within autoclaves. Autoclave Load and Drain thermocouples

More information

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only. 9142-B-P-156/AF Field Metrology Well User s Guide Distribution is limited to DoD and U.S. DoD contractors only. May 2013 2013 Fluke Corporation. All rights reserved. Specifications are subject to change

More information

Heat Shield Portable wireless WBGT meter

Heat Shield Portable wireless WBGT meter > heat shield Heat Shield Portable wireless WBGT meter Highlights Quick, real-time, reliable and accurate assessment of indoor and outdoor WBGT index Real-time assessment of the PMV-PPD index (ISO7730)

More information

Thermo-anemo-manometer MP 210

Thermo-anemo-manometer MP 210 Thermo-anemo-manometer MP 210 KEY POINTS Mesure de la pression, de la 2 entrées pour température Pt100 vitesse et du débit Modules interchangeables Jusqu'à 6 mesures en simultané Grand écran graphique

More information

ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES

ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES 2 ALINOX INSULATED CONDUCTOR RAIL Features, advantages and benefit The insulated conductor rail system ALINOX is the most suitable solution

More information

SP5 INSTALLATION AND SETUP MANUAL

SP5 INSTALLATION AND SETUP MANUAL SP5 INSTALLATION AND SETUP MANUAL 1 Installation 1.1 Introduction The SP5 System consists of a Data Acquisition unit (DAQ) with two complete Roller control channels, each Roller Control Channel consists

More information

NOTES TABLE OF CONTENTS

NOTES TABLE OF CONTENTS OI-809F NOTES TABLE OF CONTENTS Page 1.0 Introduction & Quick Start Instructions...................... 2 2.0 Operating Principle & Applications......................... 3 3.0 Equipment Supplied.....................................

More information

Tubeskin thermocouple assembly Model TC59-W

Tubeskin thermocouple assembly Model TC59-W Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-W WIKA data sheet TE 65.58 further approvals see page 7 WELD-PAD Applications Chemical industry Power generation Refineries

More information

ARDUINO WORK BENCH - PART LIST

ARDUINO WORK BENCH - PART LIST Nº Commercial Name ARDUINO WORK BENCH - PART LIST Qty. Price [ ] /unit 1 Storage plastic box (15L) 1 4.50 4.50 all Supplier The box (closed volume, insulated, transparent, thick wall but easy to pierce

More information

Pressure sensor for liquid and gaseous media QBE620-P...

Pressure sensor for liquid and gaseous media QBE620-P... 1 904 Pressure sensor for liquid and gaseous media QBE620-P... Pressure sensor for the measurement of positive pressure in HVAC applications. Piezo-resistive system of measurement DC 0...10 V output signal

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

TEMPERATURE SENSORS TEMPERATURE SENSORS

TEMPERATURE SENSORS TEMPERATURE SENSORS TEMPERATURE SENSORS TE Connectivity is a leader in the design and manufacture of NTC thermistors, RTDs, thermocouples, thermopiles, digital output and customized sensor assemblies. Building on our long

More information

CUSTOM DC MOTORS & GEARMOTORS

CUSTOM DC MOTORS & GEARMOTORS & GEARMOTORS Battery-powered, 24-volt motor with close coupled hydraulic pump mounting on one end and standard NEMA 56 C face and shaft on other end. Totally enclosed fan cooled, thyristor rated, partial

More information

Differential pressure sensor

Differential pressure sensor s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or

More information