UNIVERSAL CALIBRATOR M

Size: px
Start display at page:

Download "UNIVERSAL CALIBRATOR M"

Transcription

1 INTRODUCTION UNIVERSAL CALIBRATOR M Before going through the instruction manual for actual use of the instrument go through the specifications and take note of the following points carefully 1. No external voltage source should be imposed on the instruments voltage source output terminals. The voltage output is short circuit proof. 2. No current source should be forced through the current output terminals. An open circuit voltage of 27 volts exists on the current terminals. This voltage may be less with full 60mA load and in case when battery low indication is there in battery mode of operation. With mains voltage operation or with fully charged battery compliance voltage of current source will be 24 volts. The current source is open circuit protected. 3. For measurement of external voltage/current sources use the "sense" terminals only after selecting proper mode and range. The measurement circuit ( sense terminals ) is protected upto 30V only in any of the ranges. Applying any voltage above that may damage certain components within the instrument. 4. At the time of switch 'ON' of the instrument in Mains or Battery, display will first show the range selected for about 3 seconds. This time is required for internal reference reading and software initialization. After this the actual reading will be displayed. If the range selection is not proper instrument will display a message 'error' and stay in that mode only until a valid range is selected. 5. The instrument goes through an auto calibration cycle every 3 minutes. At which time the instrument reading will freeze to last reading for about 2 seconds. The same auto calibration cycle is executed when a new range is selected. This auto calibration cycle corrects for drifts in the instrument because of self heating. After changing range allow minimum 3 minutes time in the selected function for the instrument to stabilize at its rated accuracy. 6. Though every care has been taken to protect the instrument against voltage spikes, transients etc., should the instrument stop functioning, switch off the instrument and switch it on once again. The instrument is capable of operating on mains as well as battery operation depending upon mains supply presence. If mains supply fails instrument tries to start functioning in battery mode where the instrument may not be able to start properly. This happens because of series resistance of batteries and slow dropping of the mains supply. In such an event switch off and switch on once again to start with proper functioning. Operation Manual 1 of 19

2 7. While measuring RTD care is to be taken that proper mode is selected. If ma mode is wrongly selected with 60 ma range, the current of 60 ma can flow through the RTD, leading to its damage. It is always safer to select proper mode and type of RTD and then connect RTD. In case of no connection for RTD the instrument may read under or over range. After connecting RTD the reading will come, but it will be better to wait for 3 minutes for a stable accurate reading. ( This is because of open circuit voltage of the current source in the instrument. ) 8. If the 'NULL' switch is used in a particular range, make sure to release it before you change to new range. Keeping 'NULL' switch pressed may lead to wrong reading in other ranges. 9. The following ANSI symbols are used for various standard thermocouple types E Chromel - Constantan J Iron - Constantan K Chromel Alumel T Copper Constantan B Pt 30% Rh - Pt 6% Rh R Pt 13% Rh - Pt S Pt 10% Rh - Pt GENERAL DESCRIPTION MASIBUS' UNICAL 3001M is a micro-controller based instrument, capable of measuring and calibrating process signals (instrumentation), with the most stringent accuracy demanded by the industry. At the heart of the instrument is an 8 bit micro-controller, an 18-bit serial analog to digital convertor and indigenously developed dedicated software, that makes this unique calibrator highly reliable, versatile and precise. SALIENT FEATURES Capable of measuring the output of or simulating thermocouple types, B, E, J, K, R, S, T (ANSI standard). Capable of measuring output of Pt-100 and Cu-53 RTD and 2K resistance. Simulation of resistance and RTD by simulator module. Software controlled AUTO CALIBRATION and AUTO ZERO LOOP within measurement cycle ensures zero short term and negligible long term drifts. Automatic cold junction compensation by means of simulated electronic ice point reference and 100% digital linearization eliminates use of conversion tables and thermometers. High accuracy of linearization achieved by 10th order polynomials for multiple segments. Cold junction temperature adjustment provided on front for proper tracking. Simulation of temperature in C or F Operation Manual 2 of 19

3 Digital calibration, no trimpots used. Measures simulates mv, V and ma. Independent settings for zero and span, switch selectable. This is useful for calibration of systems which read zero for some offset voltage or current, e.g., 4 ma corresponding to ZERO and 20 ma for SPAN. All values adjusted by means of 10 turn coarse and fine potentiometers. Digital nulling facility for offset cancellation and differential measurement. Mains-Cum-rechargeable battery operated with built-in charger. Six standard 'C' size cells are used for forming a 7.2V battery. Facility to display ambient temperature at any time during measurement just by a key press. Optional facility to measure/simulate two unique user defined mv v/s parameter characteristic. For 20 ma simulation, full 24 volts compliance voltage provided even in battery mode operation. SPECIFICATIONS Power Supply : 230/110V ± 10%, 50 Hz/60 Hz, or Builtin rechargeable battery Battery : Rechargeable 7.2V, 2.2AH power pack Battery Operation : Approximately 5 Hours in measurement mode and 4 Hours with 20 ma output. Battery charging time : 14 Hours for full charge Dimension : 240(W) X 135(H) X 185(D) mm. Cold Junction Compensation : Automatic from 0 C to 50 C in both measurement and simulation. CJC switch off with 0 C reference provided. Display : 5 Digit 0.56" RED high efficiency LED Discrete Leds to indicate selected function, Battery low indication and battery charging status Reading time : 2.5 readings/sec. Input impedance : More than 10 Mohm(mV, V, T/C) 10 ohm in ma Operating temperature : 0 to 55 C Operation Manual 3 of 19

4 Humidity range : 0 to 80% R.H. non-condensing Temperature Coefficient : % rdg/ C Protection : Voltage source Short circuit Current source Open circuit Power consumption : 10 VA Enclosure : General Purpose Functions : Function Range Resolution Accuracy Ambient 0 to 50 C 0.1 C ± 0.2 C 20 mv -5mV to +25mV 1 µv ± 0.03 % F.S. 200 mv -50mV to +250mV 10 µv ± 0.03 % F.S. 2 V -0.5V to +2.5V 0.1 mv ± 0.03 % F.S. 10 V -2.5V to +10V 1 mv ± 0.03 % F.S. 20 ma 0 to +25mA 1 µa ± 0.03 % F.S. 60 ma 0 to +60mA 10 µa ± 0.03 % F.S. B type T/C 450 C to 1750 C 0.1 C ± 2.0 C E type T/C -100 C to 1000 C 0.1 C ± 0.5 C J type T/C 0 C to 760 C 0.1 C ± 0.5 C K type T/C 0 C to 1370 C 0.1 C ± 0.5 C R type T/C 200 C to 1750 C 0.1 C ± 1.0 C S type T/C 0 C to 1750 C 0.1 C ± 1.0 C T type T/C -160 C to 400 C 0.1 C ± 0.5 C PT- 100 RTD -200 C to 850 C 0.1 C ± 0.5 C CU C to 200 C 0.1 C ± 0.5 C 2K ohm 0 to 2Kohm 0.1 ohm ± 0.03 % F.S. Notes: (1) For all ranges, ± 1 count digital inaccuracy will be applicable. (2) For mv, V and thermocouple ranges, source loading capability will be maximum 10mA. (3) For current ranges compliance voltage will be 24V in mains mode. With battery it may get reduced if battery is not fully charged. (4) For Pt-100, Cu-53 and 2K ohm ranges injection current of 0.5mA is used. 1. POWER SUPPLY OPERATION Operation Manual 4 of 19

5 The instrument is having facility for both mains and battery mode of operation. Generally it is shipped with battery in discharged condition for safety purpose. The battery starts getting charged automatically when mains supply is applied even if front switch is in OFF position. When battery is getting charged, front panel LED of 'BAT CHG' will be ON. For applying mains power, a standard 3-pin mains inlet is provided on back side. The power supply of the unit is either 230V AC or 110V AC set from factory. Refer test report for power supply rating. The supply is protected by a 500 ma fuse provided in the socket itself. One spare fuse is also provided in the socket. For operating the unit just press PWR switch with mains applied or battery fully charged. If battery is not charged, unit will not turn on and if the battery is partially charged, unit will turn on with a 'BAT LO' indication on front. Select desired range of operation. It will display selected range, and then the value being measured or simulated. WARNING : Don't operate the instrument for longer time after BAT LO warning LED is ON. The time for battery supply cutting off will depend upon the range selected. In case of 60 ma the unit can be operated only for very short time while for mv or thermocouple ranges it can be operated for little longer time. 2. FRONT PLATE DESCRIPTION 2.1 DISPLAY On front there is a 0.56", five digit, seven segment numerical display for indicating the value being simulated or measured. The unit of measurement is indicated by 3 mm discrete LEDs below the display. By selection of range and unit switches, particular unit LED will glow. One LED for 'BAT LO' is provided when the internal battery voltage drops below 6.75 volts. This LED operates only in battery mode of operation. Other LED for 'BAT CHG' is for indicating charging of the battery. 2.2 ADJUSTMENTS AND SETTINGS There are three 10 turn potentiometers on front. Two of them are marked "COARSE" and "FINE" corresponding to SPAN output. One of these marked "ZERO" is for adjusting mv and ma for the zero adjustment of the instrument under test. All the three potentiometers are common for either mv, V, ma or thermocouple simulation. For RTD simulation separate RTD simulator module is to be used. There is one more single turn potentiometer provided for ambient temperature adjustment. The ambient sensor is located just between the sense terminals for Operation Manual 5 of 19

6 proper tracking of ambient temperature for thermocouples. If any tracking error is observed, the ambient temperature can be adjusted by a screw driver. 2.3 TERMINALS There are six terminals provided on the front panel. These are standard terminals accepting 4 mm jacks directly. The "SOURCE" terminals are for mv or V output as well as mv output corresponding to the thermocouple types. For ma output there are two extra terminals marked "ma O/P" with current direction arrows. "SENSE" terminals are common for all measurements. RED terminals are for positive and BLACK terminals are for negative. For RTD and resistance measurement there are three combinations possible. For two wire measurements short ma O/P+ to SENSE+ and short ma O/P- to SENSE- terminal. Connect the RTD or resistance across SENSE terminals. For four wire measurement connect two wires of one end to ma O/P+ and SENSE+ and two wires of other end to ma O/P- and SENSE-. For three wire measurement, leave ma O/P- terminal open and connect other three terminals as per four wire connection. There is a built in circuit to detect 3W or 4W mode of operation. 2.4 PUSH BUTTON SWITCHES There are three groups of six push button switches each. One group is at bottom left corner which has push to ON, push to OFF type switches. The two groups in center are having inter linked switches in each group i.e. user can select only one of them at a time. Now we will see function of each of them BOTTOM SWITCHES PWR This switch is turning ON or OFF the instrument. In pressed condition instrument remains ON. UNIT This is the second switch in lower bank. It is not labeled, but the units for temperature measurement are selectable either as C or F. In OFF position deg.c is selected and in ON position deg.f is selected. Corresponding unit LED will glow in temperature display. DISP This switch is used to display ambient temperature with any range selected. The ambient will be displayed till the switch is in ON condition. When the switch is turned OFF the display will fall back to normal mode selected by other switches. The unit of ambient temperature is selected by UNIT switch. The ambient Operation Manual 6 of 19

7 temperature sensor is located just between the two "sense" terminals but due to self heating if any deviation in ambient is found facility for adjusting ambient is provided on front plate itself by a single turn potentiometer marked "AMB ADJ". CJC This switch is used for introducing cold junction compensation for thermocouple measurements. When the switch is ON means the mv output across the "SOURCE" terminals corresponding to the thermocouple type selected is ambient compensated, i.e. this is referred to the ambient temperature prevailing. When the switch is "OUT", the mv output corresponding to the thermocouple type is referred to 0 C. This switch eliminates need to refer thermocouple charts for ambient compensation. NUL This is provided for offset cancellation and differential measurement. For example, in case there is a zero drift in 20 mv range, and the unit reads few counts with the input shorted, one can NULL the same by pressing the NUL switch in. In all subsequent measurements, the initial count which was NULLED, will be subtracted. Make sure to turn OFF NUL switch after measurement is over, otherwise it will lead to erroneous readings in other ranges. The effect of NULLING is different in Pt-100 and Cu-53 ranges. In case of other ranges, it subtracts basic raw reading (before linearization in case of thermocouples), so if CJC switch is on, the reading will show ambient when NUL switch is pressed. For thermocouple types it subtracts mv at the time of NULL instead of temperature. In case of Pt-100 and Cu-53 ranges it subtracts actual temperature after linearization and calibration. O/P This switch is used to select between ZERO and SPAN settings. When this switch is pressed in, the output which is available across the "source" terminal will be corresponding to one set by 10 turn potentiometer marked 'ZERO'.With the switch in OUT position, the output available at the 'SOURCE' terminals will be COARSE and FINE potentiometers settable 'SPAN' settting. This facility is extremely useful for calibrations wherein quick simulation of zero and span is desired like 4 ma and 20 ma. Operation Manual 7 of 19

8 2.4.2 TYPE SELECTOR SWITCHES Two switch banks in the center of the instrument are used for selecting required input/output type. The left hand side group of six switches selects the basic input group type and the right hand side group of six switches selects range or type in the group selected by left hand side switch. The switches in right hand side group (now onwards referred as second group) have multiple functions. This functions are coded by different color legends matching with the switches in left hand side group (now onwards referred as first group). For selecting any type, one switch in either group has to be pressed. If the switch selection is invalid display will show "error" until a valid switch selection is made. TCB This is the first switch in RED color in first group. This switch is used for selecting BASE METAL type thermocouples. Exact thermocouple type is decided be the switch pressed in second group. These switches in second group are also marked in RED color for convenience. With TCB pressed in pushing any of the type switch will select the particular type and output will be available across "source" terminals. One can set E, J, K, T, SP1 and SP2 type thermocouples in this mode. SP1 and SP2 are default configured as K type from factory. If user has specially ordered for any other type of thermocouple, it will be programmed for that type and display will correspond to characteristic for that type. The output available across "source" terminals will be in mv and display will be in actual temperature. The source mv range will be from -50 mv to 250 mv in this type. TCN This is second switch in first group marked in BLUE color. When this switch is selected, mode will be corresponding to noble metal thermocouples B, R, and S types (selected by corresponding switches in second group in blue color). When TCN is pressed and in second group B, R or S is selected particular range will get selected and output will be available across the "source" terminals. The output available across "source" terminals will be in mv and display will be in actual temperature. The source mv range will be from -5 mv to 25 mv in this type. RTD This is third switch in first group marked in BLACK color. There are two standard RTD types Pt-100 and Cu-53 supported and resistance measurement upto 2K ohms with a resolution of 0.1 ohms is provided. For Pt-100 and Cu-53 the unit LED of deg.c or deg.f will glow according to range selection but for 2K range no unit LED will glow. For RTD there is automatic 3W/4W detection circuit provided within the unit itself. For 3W measurements just don't use the fourth terminal of current source negative. For RTD measurements a current source of 0.5 ma is used. Operation Manual 8 of 19

9 For simulation of RTD there is no provision within the instrument. It can only measure RTD temperature or resistance. For sourcing resistance one external RTD simulator module is supplied along with instrument. mv This fourth switch in first group marked in green color. There are two ranges 20 mv and 200 mv. 20 mv range is having a resolution of 1 micro volt and 200 mv range is having a resolution of 10 micro volts. Press the corresponding switch in second group for selecting either range. For 20 mv, source range is from -5 mv to 25 mv and for 200 mv, source range is from -50 mv to 250 mv. VOLTS This is fifth switch in first group marked as 'V' in green color. There are two ranges 2V and 10V. 2V range is having a resolution of 0.1 mv and 10V range is having resolution of 1 mv. Press the corresponding switch in second group for selecting either range. For 2V, source range is -0.5V to 2.5V and for 10V, source range is -2.5V to 12.5V. In case of 10V range, the stabilization time for reading will be few seconds because of input filter. CURRENT This is last switch in first group marked as 'ma' in green color. There are two ranges 20 ma and 60 ma. 20 ma range is having a resolution of 1 micro amp and 60 ma range is having a resolution of 10 micro amp. Press the corresponding switch in second group for selecting either range. For 20 ma source range is 0 ma to 25 ma. For 60 ma range the source is 0mA to 60 ma. In 60 ma range there is no over range. The instrument may show erroneous reading in 60 ma range, if you try to switch on with full current source. So, it will be advisable to switch on the instrument with low current and then increase the current gradually to full scale. This type of problem may come specially when battery voltage is low. While using 60 ma range be careful while making connections be cause excessive current may some time damage the unit under calibration. Compliance voltage of current source is specified as 24V and is valid for 20 ma range with mains operation or fully charged battery. If the battery voltage is low the voltage may be low. In case of 60 ma range the maximum compliance voltage at full scale may be about 20V. 2.5 EXAMPLES FOR USE Operation of any instrument can be best explained by examples. Few examples are given for various ranges. The schematic drawings for connections for this are also enclosed mv simulation Operation Manual 9 of 19

10 Select the switch marked mv in first group and 20 mv marked in second group. For 20 mv range due to thermal EMF in the instrument and the lead wire resistance of the internal wiring there can be a zero error in measurement. For using this range, first short the two sense terminals. The instrument may be reading a few microvolts. Press the null switch to make the reading zero at this point. Now, the zero error of instrument is compensated in this range. Now, remove the short across sense terminals and short source positive with sense positive and source negative with sense negative. Now the instrument is in simulation mode and you can set for required value by using COARSE and FINE pots V simulation Select the switch marked 'V' in first group and 10V marked in second group. Short the source and sense positive terminals and source and sense negative terminals. The output voltage will be displayed and will be available across the positive and negative terminals Setting 4 ma corresponding to ZERO and 20 ma corresponding to SPAN. Select the ma switch in first group and 20 ma range switch in second group. Short the two terminals marked 1 & 2 together and 3 & 4 together. Use COARSE and FINE pots to set the display to read ma. Now, press the ZERO/SPAN switch IN. Using the pot corresponding to ZERO, make the display to read ma. Now with the ZERO/SPAN switch in IN position instrument will source ma and with switch in OUT position it will source ma. For feeding this current to instrument under test, break the link between 1 & 2 and connect the instrument across these two terminals. The current path will get completed if the instrument is having a load resistance and the current will remain the same if it is not exceeding the compliance voltage range. If the reading shows zero, check the connections of the instrument, either the input terminals on instrument will be open or connection may be reverse. For feeding the current, user can connect the load across terminals 3 & 4 also with terminals 1 & 2 shorted by a link. The instrument will give same performance in both the methods of connections. After connecting the load calibrate the instrument under test by iterative switching of the ZERO/SPAN switch until both zero and span calibrations on the instrument under test are matching K type thermocouple simulation with ambient compensation. Let us try to set 1000 C for K type thermocouple with ambient compensation. Operation Manual 10 of 19

11 First press TCB and K switches to select the K type thermocouple. Also keep the CJC switch pressed. Short the two positive terminals of SOURCE and SENSE and two negative terminals of SOURCE and SENSE. Using the COARSE and FINE pots set the instrument to read 1000 C. Output mv available across source terminals will now be corresponding to 1000 C with mv subtracted for ambient temperature prevailing R type thermocouple simulation with ambient compensation. Let us try to set 1500 C for R type thermocouple with ambient compensation. First press TCN and R switches to select R type thermocouple. First short the sense terminals to see if there is any zero error in this range. If instrument is showing some reading with the terminals shorted, press NUL switch to cancel this. Now the instrument will read 0.0 temperature. Make sure, CJC switch is in out position. Now Press CJC switch IN and short the source and sense terminals. With the help of COARSE and FINE pots set the instrument to read C. Output mv available across source terminals will be corresponding to 1500C with mv for prevailing ambient subtracted PT-100 RTD measurement For this just press RTD and Pt-100 switches and connect the RTD across the terminals. Connection will depend upon whether the measurement is 3W or 4W. For 4W measurement connect all four leads and for 3W connect only first three terminals leaving fourth terminal open. The display will directly show the temperature in C or F depending upon the selection of unit Resistance simulation For simulation of resistance, select the 2K resistance range by pressing RTD and 2K switched. short terminals 1 & 2 and terminals 3 & 4. Connect terminals 2 & 3 to measure terminals of RTD simulator. With the RTD simulator switch in measure position, set the required resistance value by coarse and fine pots on the RTD simulator. The calibrator will read the resistance value. Now the switch can be turned to source position where the instrument under measurement can be connected. At this time a fixed resistance of 100 ohms is place across measure terminals so that the calibrator current source will not get open circuit. 3. CALIBRATION The instrument is calibrated at the factory for all the ranges with the help of a 6-1/2 digit or better multimeter. As a standard practice all calibrating instruments have to Operation Manual 11 of 19

12 be checked for deviation in calibration every year. This is necessary to compensate the effect of long term drift of the components used within the instrument. All the calibration parameters are stored in EEPROM inside the instrument. All necessary protections are made for protection of EEPROM data. Also there is a software algorithm included to give one level of protection against such disturbance. In spite of all these, due to heavy transients on the power supply or due to power fluctuations or noise in power line, if the calibration data gets disturbed, a warning is given. This warning is given by displaying a message "CALoF" for two seconds whenever a new range is switched. If this message is displayed, the instrument calibration is off and the reading accuracy is not guaranteed. In such a case it is better to recalibrate that particular range. The calibration procedure for the instrument is made very simple. The calibration is done at pre-defined points by just DIP switches. Before altering the calibration make sure to have proper instruments to calibrate this instrument. The multimeter to be used for cross checking it should be at least 5-1/2 digit with accuracy specifications better then this calibrator. For RTD/resistance calibration use decade BOX or resistance BOX with an accuracy of 0.01% or better. For calibration, first open the top cover by unscrewing the four screws on top. There is one horizontal card on the instrument called CPU card. On this card on the rear end, towards right there is one 4-way DIP switch. This switch is used for calibration purposes. For every range calibration point is fixed at a particular value listed in the table given in section CALIBRATION OF RANGES EXCEPT RTD Connect the output of the calibrator to a accurate multimeter and set it to the required value( Except for RTD types). If there is any deviation from the required value, turn ON the first two switches of the DIP switch. The instrument reading will match the reading indicated on standard multimeter within one/two seconds. If it is not matching, there can be something wrong with the instrument. If the difference between standard meter and calibrator is more than 5 % it will be unable to calibrate. Once the reading matches, put the switches back to OFF position. All the ranges can be calibrated one by one using this method. For 20 mv range and Noble metal thermocouple ranges ( B, R and S ), it is necessary to NULL the zero error before calibrating. Prior to calibrating first NULL the reading displayed with sense terminals shorted. Then remove the short and perform the same procedure like other types. 3.2 CALIBRATION OF RTD RANGES Operation Manual 12 of 19

13 In case of RTD types user has to feed the resistance from a standard resistance box or set it with the help of RTD simulator supplied and measure it on a standard multimeter. 3.3 AMBIENT CALIBRATION For ambient calibration, there is no need to open the instrument. It can be adjusted any time by means of a single turn pot marked "AMB ADJ" on front plate. 3.4 CALIBRATION POINTS RANGE MULTIMETER UNICAL READING READING 20 mv mv mv 200 mv mv mv 2 V V V 10V V V 20 ma ma ma 60 ma ma ma E t/c mv C * J t/c mv C * K t/c mv C * T t/c mv C * B t/c mv C * R t/c mv C * S t/c mv C * Pt ohm C Cu ohm C 2K ohm kohm kohm * CJC switch should be in off position. Note : For SP1 and SP2 calibration points are decided by the curve supplied by the user. Temperature calibration Standards as per IPTS COMMON CALIBRATION POINTS For some of the ranges calibration parameters are same. While calibrating, when one of the ranges is calibrated all the ranges in same group get calibrated. The grouping of ranges is as below a. 20 mv, B t/c, R t/c and S t/c b. E t/c, J t/c, K t/c and T t/c Operation Manual 13 of 19

14 c. Pt-100 and Cu BATTERIES The instrument is having six Ni-Cd batteries soldered on the power supply card at bottom. The batteries are automatically charged when mains supply is applied irrespective of the position of PWR switch. The charging indication is given by 'BAT CHG' LED on front plate. If the battery is fully discharged, keep it in charging for 14 to 16 hours before starting instrument on battery. The instrument is having built-in undervoltage cut-off circuit for battery operation. After BAT LO condition if the user continues to use the instrument for long period at one point of time instrument will stop functioning. In this condition still the unit draws few ma current from battery to keep the cut-off circuit active. So, PWR switch should be immediately switched off in this condition and the battery should be charged before reusing the unit. If the battery gets deep discharged, it may not be possible to charge it again and may get permanently damaged. When Ni-Cd cells get charged, there is a rise in internal temperature of the battery because of the energy pumped in the battery. So, the battery manufacturers recommend charging of the batteries to be performed at an ambient temperature below 40C. As such the instrument storage temperature specified is high, but it is advisable to store the instrument at a temperature below 40C for longer self life of the battery. 5. RTD SIMULATOR While Masibus UNICAL 3001M simulates and measures mv, Volts, ma and thermocouples, it only measures in RTD and resistance ranges. For simulating RTD and resistance a compact passive RTD simulator is provided which can be used with the UNICAL to calibrate RTD type of instruments. The procedure to check/calibrate RTD type of instruments is as follows 1. Connect the instrument under calibration as shown in drawing. 2. Switch on UNICAL and the instrument under test and allow some time for stabilization. 3. Select UNICAL for RTD mode by pressing RTD switch and the respective range. 4. Keep the RTD simulator MEASURE/SOURCE switch in 'MEASURE' position and adjust the desired reading by means of 'coarse' and 'fine' pots, reading the value on unical. Operation Manual 14 of 19

15 5. Once having set the potentiometer to the desired value, without disturbing the pot position throw the MEASURE/SOURCE switch in 'SOURCE' position. The resistance value adjusted on UNICAL will now be fed to the instrument under calibration. The RTD simulator can simulate resistance upto 2.1 k ohms. The COARSE potentiometer is of 2K and fine potentiometer is 100ohms. Both potentiometers are 10 turn for better resolution. FIGURE 1: mv, T/C OR Volt simulation mode SOURCE M + - Instrument under test Operation Manual 15 of 19

16 FIGURE 2: mv, T/C OR Volt measurement mode SOURCE SENSE M + - Signal to be measured FIGURE 3: Current measurement mode SOURCE ma o/p SENSE ma o/p M + - Current Signal to be measured Operation Manual 16 of 19

17 FIGURE 4: Current Simulation mode SOURCE ma o/p SENSE ma o/p M OR + - Instrument Under test SOURCE ma o/p SENSE ma o/p M + - Instrument under test Operation Manual 17 of 19

18 FIGURE 5: RTD 3 wire measurement mode SOURCE ma o/p SENSE ma o/p M RTD to be measured FIGURE 6: RTD 4 wire measurement mode SOURCE ma o/p SENSE ma o/p M FIGURE 7: RTD Simulation with RTD simulator RTD to be measured Operation Manual 18 of 19

19 SOURCE ma o/p SENSE ma o/p M INSTRUMENT UNDER CALIBRATION SOURCE MEASURE FINE COARSE RTD SIMULATOR Operation Manual 19 of 19

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics Model 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE

More information

Model 422 Automated Thermocouple Calibrator Operating Instructions. Product Description

Model 422 Automated Thermocouple Calibrator Operating Instructions. Product Description Model 422 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 422 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console.

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console. SP4 DOCUMENTATION 1. SP4 Reference manual.... 1 1.1. SP4 console... 1 1.2 Configuration... 3 1.3 SP4 I/O module.... 6 2. Dynamometer Installation... 7 2.1. Installation parts.... 8 2.2. Connectors and

More information

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy Instruction Manual Digital Panel Meter Model 3126 I-01861 1. Preface Thank you for purchasing our digital panel meter 3126 series. Before use, read this manual carefully and thoroughly, and keep this manual

More information

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description PIECAL 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322-1 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

Thermocouples. Thermocouple

Thermocouples. Thermocouple Thermocouple Nimish Shah Thermocouples Most frequently used method to measure temperatures with an electrical output signal. Outline What Is A Thermocouple Sensor?? Basic Working Principle Practical Thermocouple

More information

Harris IRT Enterprises Digital Resistance Tester Model XP

Harris IRT Enterprises Digital Resistance Tester Model XP Harris IRT Enterprises Digital Resistance Tester Model 5012-06XP Specifications & Dimensions 2 Theory of Operation 3 Operator Controls & Connectors 4 Test Connections 5 Calibration Procedure 6-7 Options

More information

Time Electronics DC Multifunction Voltage/Current/Resistance Calibrator. Technical Manual

Time Electronics DC Multifunction Voltage/Current/Resistance Calibrator. Technical Manual Time Electronics 1017 DC Multifunction Voltage/Current/Resistance Calibrator Technical Manual V1.2 01/11/10 Time Electronics Ltd Botany Industrial Estate, Tonbridge, Kent, TN9 1RH Tel: +44(0)1732 355993

More information

Time Electronics DC Voltage Calibrator. Technical Manual

Time Electronics DC Voltage Calibrator. Technical Manual Time Electronics 1010 DC Voltage Calibrator Technical Manual V1.1 20/04/09 Time Electronics Ltd Botany Industrial Estate, Tonbridge, Kent, TN9 1RH Tel: +44(0)1732 355993 Fax: +44(0)1732 770312 Email: mail@timeelectronics.co.uk

More information

Troubleshooting Bosch Proportional Valves

Troubleshooting Bosch Proportional Valves Troubleshooting Bosch Proportional Valves An Informative Webinar Developed by GPM Hydraulic Consulting, Inc. Instructed By Copyright, 2009 GPM Hydraulic Consulting, Inc. TABLE OF CONTENTS Bosch Valves

More information

TMD90A Dual Input Digital Thermometer

TMD90A Dual Input Digital Thermometer TMD90A Dual Input Digital Thermometer User Manual For detailed specifications and ordering info go to www.testequipmentdepot.com TMD90A Dual Input Thermometer Contents Safety Information 2 Symbols Used

More information

PIECAL 520B & 521B Thermocouple Source Operating Instructions

PIECAL 520B & 521B Thermocouple Source Operating Instructions PIECAL 520B & 521B Thermocouple Source Operating Instructions (Shown without optional boot) Product Description Easy to use With the PIECAL 520B/521B you can check & calibrate all your thermocouple instruments.

More information

PTC8001 Temperature Calibrator

PTC8001 Temperature Calibrator PTC8001 Temperature Calibrator Table of Contents 1. Introduction....................1 1.1 Customer Service................1 1.2 Standard Equipment..............1 1.3 Safety Information................2

More information

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used

More information

Virtual Ground for HV Boosters Calibration

Virtual Ground for HV Boosters Calibration Dear all utracer users, I m writing these lines just to share my experience building my utracer, so that maybe someone could find it useful for his design. The construction of my utracer was very simple,

More information

User Manual 123electric Battery Management System 123\BMS Revision 1.4 Augusts 2015

User Manual 123electric Battery Management System 123\BMS Revision 1.4 Augusts 2015 User Manual 123electric Battery Management System 123\BMS Revision 1.4 Augusts 2015 Table of contents Introduction... 3 System structure... 3 Keep the batteries in a perfect condition : ALWAYS!... 5 Specifications...

More information

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments Time Electronics Calibration, Test and Measurement Portable Process and Pressure Calibration Instruments Calibrators Simulators Sources Pumps Gauges www.timeelectronics.com Loop & Temperature Calibration

More information

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument 7526A Precision Process Calibrator Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument The 7526A Precision Process Calibrator calibrates a wide range of pressure

More information

Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual

Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual Burns Connection Head Models #, # & # Burns Connection Head Models #, # & # with Battery Powered LCD Indicator Instruction Manual Contents Introduction General Receiving Specifications General RTD At 0

More information

EV Display User Guide

EV Display User Guide EV Display User Guide CleanPowerAuto LLC Brief Description: EV Display is designed to track battery state of charge and other related data in battery powered Electric Vehicle. EV Display is primarily designed

More information

XK3190- A7. Weighing indicator USER MANUAL

XK3190- A7. Weighing indicator USER MANUAL XK3190- A7 Weighing indicator USER MANUAL Directory Chapter 1. Main Specification......,,...2 Chapter 2 Installation...,...3 Front and Back View of Indicator...,..3 Connecting Loadcell to Indicator...,...4

More information

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL 72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com

More information

BAPI-Stat 3 Room Sensor

BAPI-Stat 3 Room Sensor Overview and Identification The BAPI-Stat 3 is a multiple output transmitter for temperature and humidity with setpoint capability for both and occupied/unoccupied override switching. The large easy-to-read

More information

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

LAVOLTA DC REGULATED POWER SUPPLY BPS-305 LAVOLTA DC REGULATED POWER SUPPLY BPS-305 USER MANUAL 1 In order to use the power supply better, please read the user manual carefully before using and keeping it properly. Warning: Do not connect any

More information

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations DLRO 10 and DLRO 10X DESCRIPTION NEW interchangeable test lead terminations Auto current reversal cancels standing emfs Protected to 600 V Automatically detects continuity in potential and current connections

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

Constant Voltage/Constant Current Test System

Constant Voltage/Constant Current Test System Description Constant Voltage/Constant Current Test System The Constant Voltage/Current Test System may be used for constant voltage or constant current pulse testing of automotive and aerospace igniters,

More information

TROUBLESHOOTING AND MAINTAINING ELECTRONIC KILN CONTROL SYSTEMS

TROUBLESHOOTING AND MAINTAINING ELECTRONIC KILN CONTROL SYSTEMS TROUBLESHOOTING AND MAINTAINING ELECTRONIC KILN CONTROL SYSTEMS Tom Salicos American Wood Dryers Clackamas, Oregon After many years of helping American Wood Dryers' customers troubleshoot dry kiln control

More information

EGT-100 Operations and Installation Manual

EGT-100 Operations and Installation Manual Page 1 of 11 All specification subject to change 2002-2005 EGT-100 Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual with any

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER VARIABLE SPEED DRIVE CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER With PC101 Torque Limit Control WARNING Disconnect all incoming power before working on this equipment. Follow

More information

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions 335 E Warner Rd. STE 3 Chandler, AZ 85225 www.elitepowersolutions.com ABC Operation Manual Page 1 Table of Contents

More information

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor. sales@jumo.co.uk info.us@jumo.net Page 1/8 JUMO thermocor Portable measuring system for AMS2750 and CQI-9 Brief description The JUMO thermocor is a high-precision documenting test device with 12 analog

More information

Model ½ Digit Multimeter

Model ½ Digit Multimeter www.keithley.com Model 2110 5½ Digit Multimeter Calibration Manual 2110-905-01 Rev. C / August 2013 *P211090501C* 2110-905-01 A Greater Measure of Confidence A Tektronix Company Model 2110 5½ Digit Multimeter

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER WARNING Disconnect all incoming power before working on this equipment. Follow power lockout procedures. Use extreme caution around electrical

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82314 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.

More information

Analog input module. Brief description. Page 1/8. Data Sheet

Analog input module. Brief description. Page 1/8. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM 2 Table of Contents Introduction:... 3 1.0: Operation Principles:... 3 1.1: Stand alone supply... 3 1.2: Backed up supply:... 3 1.3: Battery

More information

Programming of different charge methods with the BaSyTec Battery Test System

Programming of different charge methods with the BaSyTec Battery Test System Programming of different charge methods with the BaSyTec Battery Test System Important Note: You have to use the basytec software version 4.0.6.0 or later in the ethernet operation mode if you use the

More information

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance

More information

PRECISION MILLI/MICRO OHMMETER INSTRUCTION MANUAL

PRECISION MILLI/MICRO OHMMETER INSTRUCTION MANUAL 72-7400 PRECISION MILLI/MICRO OHMMETER INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 3 EMC 4 Safety 5 Installation 6 Connections 7 Front Panel Controls 8 Operation 9 Maintenance 12

More information

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved. MANUAL ECM Motor ECM / ECM-DX Series v100 Issue Date: 08/15/17 2017 Price Industries Limited. All rights reserved. ECM MOTOR TABLE OF CONTENTS ECM Motor Background...1 ECM Motor Power and Control Connectors...2

More information

L300P Inverter Specifications

L300P Inverter Specifications L300P Inverter Specifications Tables for 200V class inverters Note that General Specifications on page 1 9 covers all L300P inverters, followed by footnotes for all specifications tables. Seven 200V models

More information

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor. Page 1/8 JUMO thermocor Portable measuring system for AMS2750 and CQI-9 Brief description The JUMO thermocor is a high-precision documenting test device with 12 analog inputs for thermocouples. The use

More information

Sensors and Accessories

Sensors and Accessories Sensors and Accessories Thermistors are another way of protecting or monitoring a device. Thermistors are thermally sensitive resistors and are grouped in two types: Negative Temperature Coefficient (NTC)

More information

INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07. A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators

INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07. A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07 A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators This is a premium quality product at a reasonable price, and

More information

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit Instruction Sheet 10 2004 Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit 541 0810 GENERAL INFORMATION This kit contains one Control Communications Module (CCM-G) with

More information

ASC300. Advanced Signal Calibrator. Process signal calibrator with superior accuracy. Specification Sheet

ASC300. Advanced Signal Calibrator. Process signal calibrator with superior accuracy. Specification Sheet s i g n a l ASC300 Advanced Signal Calibrator Process signal calibrator with superior accuracy. Multi-function signal calibrator With high accuracy. Ideal for both field and maintenance shop use. Input

More information

DST400 Digi-Stem Thermometer User Manual

DST400 Digi-Stem Thermometer User Manual DST400 Digi-Stem Thermometer User Manual 01/08/13 WD1095 Rev C (02/19/15) Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free 800-421-2853 Phone 828-658-3131 Fax 828-658-0728

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

LBC Series Battery Charger Instructions

LBC Series Battery Charger Instructions Ver1.2 Date: 2016/03/22 Version History Date Version Content 2014-05-19 1.0 Start Publishing 2015-03-12 1.1 Add BOOST, Charging Failure Alarm function 2016-03-22 1.2 Modify details : T:+86-769-23836636

More information

JConn Inv. PID Controller Instruction Manual

JConn Inv. PID Controller Instruction Manual JConn Inv. PID Controller Instruction Manual This information is specific to the Mypin TA4 based controller sold by JConn Inv. but it should work for most TA4 types - within limits. Table of Contents 1.

More information

Low Profile DC Power Supply with Zero Voltage Soft Switching

Low Profile DC Power Supply with Zero Voltage Soft Switching Sorensen XFR Series Low Profile DC Power Supply with Zero Voltage Soft Switching Analog programming Zero voltage soft switching Constant voltage or constant current operation with automatic crossover and

More information

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710 An ISO 9001:2008 Company THERMOCOUPLE CALIBRATOR Mode KM-CAL-710 Thermocouple Process Calibrator is a exactitude measurement and source handhold instrument, it can be use to calibrate the Thermocouple

More information

GF1900 SULFURYL FLUORIDE MONITOR

GF1900 SULFURYL FLUORIDE MONITOR GF1900 SULFURYL FLUORIDE MONITOR Revision: H Release Date: 12/12/2018 Page 1 of 20 This page intentionally left blank Revision: H Release Date: 12/12/2018 Page 2 of 20 TABLE OF CONTENTS INTRODUCTION......

More information

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3 The RCS-6V kit Page of Contents Page 1. This Book 1.1. Warning & safety 3 1.2. What can I do with the RCS-kit? 3 1.3. Tips 3 2. The principle of the system 2.1. How the load measurement system works 5

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.

More information

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101 PEAKTRONICS The Peaktronics DC Motor Controller is used for proportional positioning of actuators that use either DC motors or DC solenoids. The wide operating range of the (10 to 30 VDC and loads up to

More information

Model 2053 Conductivity Meter Instruction Manual

Model 2053 Conductivity Meter Instruction Manual Model 2053 Conductivity Meter Instruction Manual Printed in U.S.A. 09/2006 Ship Date: Serial Number: Calibrated By: Table of Contents Page 1. Introduction.. 1 2. Shipping Checklist.. 1 3. Specifications...

More information

SECTION DC POWER SUPPLY/BATTERY CHARGER

SECTION DC POWER SUPPLY/BATTERY CHARGER SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance

More information

BASIC ELECTRICAL MEASUREMENTS By David Navone

BASIC ELECTRICAL MEASUREMENTS By David Navone BASIC ELECTRICAL MEASUREMENTS By David Navone Just about every component designed to operate in an automobile was designed to run on a nominal 12 volts. When this voltage, V, is applied across a resistance,

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller Rover Series Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller 0 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.5 Important Safety Instructions Please save these

More information

707Ex. Users Manual. ma Calibrator

707Ex. Users Manual. ma Calibrator 707Ex ma Calibrator Users Manual March 2003 Rev 2 3/03(English) 2003 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. Table of Contents

More information

KEPCO Will Point You In The Right Direction!

KEPCO Will Point You In The Right Direction! Looking For A High Power, Low Profile Power Supply? KEPCO Will Point You In The Right Direction! -9 AN ISO 900 COMPANY You'll Always Find What You Need At Kepco KLN Series Programmable Power Supply: 0W

More information

System 350 S350P Proportional Plus Integral Temperature Stage Module

System 350 S350P Proportional Plus Integral Temperature Stage Module FANs 930, 930.5 Add-On Modules Section Product/Technical Bulletin S350P Issue Date 0997 System 350 S350P Proportional Plus Integral Temperature Stage Module The S350P is used in conjunction with the A350

More information

RS MODEL 2030

RS MODEL 2030 RS375-2798 MODEL 2030 THERMOCOUPLE THERMOMETER / SIMULATOR FEATURES A high accuracy instrument that will give you confidence in your other instruments. The simulator was designed to simulate a known temperature

More information

Professional Wireless Products

Professional Wireless Products Page 1 of 6 093115 Communications Power Supply and Battery Management Controller Page 2 of 6 1.0 Introduction The 093115 is a 13.8 volt 15amp transformer isolated switch mode down converter designed to

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-10 PELTIER TEMPERATURE CONTROL SYSTEM

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-10 PELTIER TEMPERATURE CONTROL SYSTEM OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-10 PELTIER TEMPERATURE CONTROL SYSTEM VERSION 2.51 npi 2002 npi electronic GmbH, Hauptstrasse 96, D-71732 Tamm, Germany Phone +49 (0)7141-601534;

More information

INTECH Micro 2300-RTD6

INTECH Micro 2300-RTD6 INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent

More information

FL-100-R (109) Operations and Installation Manual

FL-100-R (109) Operations and Installation Manual Page 1 of 23 All specification subject to change 2002-2005 FL-100-R (109) Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual

More information

True RMS Autoranging Multimeter

True RMS Autoranging Multimeter Owner's Manual True RMS Autoranging Multimeter Model No. 73754 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE MANUAL

THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE MANUAL Macintyre Electronic Design Associates Inc. 43676 Trade Center Place, Suite 145, Dulles, VA 20166 Phone: (703) 996-8990 FAX: (703) 996-8770 e-mail: sales@meda.com THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

DC POWER SUPPLY ALIMENTATION C.C.

DC POWER SUPPLY ALIMENTATION C.C. DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify

More information

Coriolis Density Error Compensating for Ambient Temperature Effects

Coriolis Density Error Compensating for Ambient Temperature Effects Coriolis Density Error Compensating for Ambient Temperature Effects Presented by Gordon Lindsay Oil & Gas Focus Group December 2018 Contents Project aims and objectives Experiment Setup Phase 1 Exploratory

More information

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Sola/Hevi-Duty S3K Series Mini-Tower UPS Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical

More information

CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL

CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL 0 M P A N Y 3879 SOUTH MAIN STREET 714-979-6491 SANTA ANA, CALIFORNIA 92707-5710 U.S.A. This manual contains information for installing and operating

More information

5A LOW DROPOUT POSITIVE REGULATOR

5A LOW DROPOUT POSITIVE REGULATOR 5A LOW DROPOUT POSITIVE REGULATOR Features Output Current : 5A Maximum Input Voltage : 12V Adjustable Output Voltage or Fixed 1.8V, 3.3V, 5.0V Current Limiting and Thermal Protection Standard 3Pin Power

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831)

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831) TECHNICAL NOTE #4 Revised May 24, 2004 BOGART ENGINEERING 19020 Two Bar Road, Boulder Creek, CA 95006 (831) 338-0616 TROUBLESHOOTING the TriMetric battery monitor Revised for the TM-2020 TriMetric What

More information

Autoranging Multimeter

Autoranging Multimeter Owner's Manual Autoranging Multimeter Model No. 82334 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J. EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Instruction Manual Model 2831D 4 ½ Digit True RMS Digital Multimeter 1 1. PRODUCT DESCRIPTION 1-1. Introduction Thank you

More information

Sól Dual Voltage Buck Boost Solar Charge Controller Connection & Operation V1.00

Sól Dual Voltage Buck Boost Solar Charge Controller Connection & Operation V1.00 Sól Dual Voltage Buck Boost Solar Charge Controller Connection & Operation V1.00 Connection Instructions Remove Bottom 4 cover to attach wires to terminal blocks then attach cover and flip over for mounting

More information

Volt/mA Calibrator. Manual

Volt/mA Calibrator. Manual Volt/mA Calibrator Manual Safety Information To avoid possible electric shock or personal injury: Never apply more than 30V between any two jacks, or between any jack and earth ground. Make sure the battery

More information

HOW TO DETERMINE TEMPERATURE BY MEASURING THE OUTPUT MILLIVOLTAGE OF A THERMOCOUPLE SHREVEPORT ENGINEERING DEPARTMENT DOCUMENT

HOW TO DETERMINE TEMPERATURE BY MEASURING THE OUTPUT MILLIVOLTAGE OF A THERMOCOUPLE SHREVEPORT ENGINEERING DEPARTMENT DOCUMENT Page 1 of 41 HOW TO DETERMINE TEMPERATURE BY MEASURING THE OUTPUT MILLIVOLTAGE OF A THERMOCOUPLE SHREVEPORT ENGINEERING DEPARTMENT DOCUMENT THERMOCOUPLE REFERENCE TABLES The N.I.S.T. (National Institute

More information

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator Table of Contents Page Introduction... 1 Description... 1 Specifications... 2 Installation... 3 Calibration... 4 General Maintenance...

More information

User s Manual. K Type Thermometer DT1311, DT1312

User s Manual. K Type Thermometer DT1311, DT1312 User s Manual K Type Thermometer DT1311, DT1312 1. Features Introduction This product is a K-type thermocouple temperature sensor for sensor digital thermometer, which converts thermal electromotive force

More information

DIGITAL MICROHMMETER TYPE DO7

DIGITAL MICROHMMETER TYPE DO7 DIGITAL MICROHMMETER TYPE DO7 Supplied Accessories:...3 1. SAFETY...3 WARNING!...3 2. INTRODUCTION...4 Display range 6000...4 3. MEASURING PRINCIPLE...4 4. CASE DESIGN...4 5. MAINTENANCE...4 6. BATTERY

More information

MAGPOWR Spyder-Plus-S1 Tension Control

MAGPOWR Spyder-Plus-S1 Tension Control MAGPOWR TENSION CONTROL MAGPOWR Spyder-Plus-S1 Tension Control Instruction Manual Figure 1 EN MI 850A351 1 A COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess International,

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

MWF+ Application. Types Available. Average temperature sensor. Datasheet

MWF+ Application. Types Available. Average temperature sensor. Datasheet MWF+ Average temperature sensor Datasheet Subject to technical alteration Issue date: 28.03.2018 A002 Application Duct averaging temperature sensor in enclosure USE-S for measuring the average temperature

More information

Use the instructions in this document to troubleshoot any issue with Digital EPIC-2.

Use the instructions in this document to troubleshoot any issue with Digital EPIC-2. Use the instructions in this document to troubleshoot any issue with Digital EPIC-2. Table of contents 1. Introduction... 2 2. Calibration errors... 2 2.1 Valve close error... 3 2.2 Valve open error...

More information

METROTEC A15-N. Oxygen Sensor Type A15-N. *** Version 1.5 ***

METROTEC A15-N. Oxygen Sensor Type A15-N. *** Version 1.5 *** Systems for oxygen measurement A15-N Oxygen Sensor Type A15-N *** Version 1.5 *** Declaration of Conformity for Oxygen Sensor Type A15-N This device has been designed for industrial purposes in accordance

More information

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible DC Drives Flexible & Powerful single-phase DC drives provide a complete family solution from the compact Series 2120 chassis drive to the powerful Series 2230 and it s feature rich application specific

More information

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE ISO-TECH IDM97II DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 WARNING THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID

More information