ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications"

Transcription

1 $ PROGRAMMABLE POWER SUPPLY EAN CODE : output Powerfull POWERFUL ALR3220 VISUAL : Large graphic display SOFT-TOUCH : Sensitiv keypad CONNECTED : USB, RS232, RS485 & 0-10V isolated LabVIEW as a standard PERFORMANCE : output in the rear-panel,used for remote-sensing FUNCTIONS : square, positive and negative ramp, rise or fall time ELEGANT : New design and feathery SPACE-SAVING : vertical & COMPACT BOX / 640W PRACTICAL : Lightweight with built-in handle and cord storage area. QUIET : Silent temperature-controlled fan cooling. LOCKING : configuration & stand-by 640 WATTS 0-32V 0-20A LabVIEW ULTRA-COMPACT!!! C Voltage Floating outputs : on 4mm safety terminals in the front-panel, and on screw terminal block for 2.5mm² on the rear-panel. Automatic constant voltage operation. Adjustable from 0 to Volts (0 to ±10mV) ; resolution : 10mV. Setting accuracy : < 0,03% that to say ±10 mv. Regulation : < 50mV for a load change from 10 to 90%. < 1mV for a ±10% line change. Ripple : < 1mV rms including : < 3 mv peak to peak of noise (BP 20 MHz) < 15mV peak to peak of switching spikes Internal resistance : < 4mΩ. Display : 4 digits on graphic LCD. Accuracy measurement : < 0,03% that to say ±10 mv. Automatic constant current operation. Adjustable from 0 to Amps ; resolution : 10mA. Setting accuracy : < 0,05% that to say ±10 ma. Regulation : < 10mA for a load charge from 10 to 90%. < 1mA for a ±10% line charge. Ondulation : < 6mA peak to peak or 2mA rms. Display : 4 digits on graphic LCD. Accuracy measurement : < 0,05% that to say ±10 ma. s Against short-circuits, by current regulation. Against overtemperature by fan and thermal circuit-breaker. Against overcurrent on main input, by internal fuses. Various and functions Dispaly : Graphic LCD 128 x 64 pixels with white backlight. Visualization of all parameters CV (Constant Voltage) mode or CC (Constant ) Memories : 16 including 15 configurable. OVP/OCP : Against overvoltage and overcurrent, adjustable from 0 to maxi. Functions : 6 available on U or I (Arbitrary, square, rising and falling periodically ramp, rise or fall time single shot). Time adjustement from 10ms to 60mn. Remote sensing : automatic function on the front side output. 4 wires mode on the back-side's terminal blocks. Correction of the voltage drop in the wires : 2V Standby : output, enable / disabled and standby of the power supply. Interfaces All the interfaces are insulated of the output (150V max). USB, RS232 and RS485 as a standard. LabVIEW's drivers as a standard. Controller 0 10V : for U and I by direct input 0-10V or potentiometer 10K or adjustable resistance 10K. In the back side on disconnect scribe terminal blocks. : Class I, enhanced safety between mains input and outputs. Complies with EN , CAT II. CEM : Complies with EN and EN Input voltage : Volts ±10%, 50 / 60Hz. Mains input : Socket CE14 with C13, 2 poles + earth cable removable Power consumption : 770W maxi. Efficiency : > 84% of the maxi powerful. Operating temperature : +5 to +40 C. Coefficient of temperature / C : 0.01% for the voltage ; 0.05% for the current. Voltage on the earth : 100V Max. Presentation : Front-panel with sensitiv keypad, rear-panel with handle and cord storage area, metallic case with epoxy finish. 3

2 PROGRAMMABLE POWER SUPPLY EAN CODE : outputs Powerfull DOUBLE ALR3206D VISUAL : Large graphic display SOFT-TOUCH : Sensitiv keypad CONNECTED : USB, RS485 & 0-10V isolated LabVIEW as a standard PERFORMANCE : output in the rear-panel,used for remote-sensing COUPLING : Auto mode : Series, Parallel, Tracking FUNCTIONS : square, positive and negative ramp, rise or fall time ELEGANT : New design and feathery SPACE-SAVING : vertical & COMPACT BOX / 390W PRACTICAL : Lightweight with built-in handle and cord storage area. QUIET : Silent temperature-controlled fan cooling. LOCKING : configuration & stand-by 390 WATTS 2 x 0-32 V 0-6 A or 1 x ± 0-32 V 0-6 A or 1 x 0-64 V 0-6 A or 1 x 0-32 V 0-12 A LabVIEW ULTRA-COMPACT!! $ ' C Floating outputs : on 4mm safety terminals in the front-panel, and on spring terminal block with levers for 2mm² on the rear-panel. Automatic constant voltage and current operation. Channel 1 and 2 MASTER AND SLAVE Independent Tracking Series Parallel Output voltage 2 x 0-32 V ± 0-32 V 0-64 V 0-32 V Minimum voltage ± 10 mv ± 10 mv ± 20 mv ± 10 mv Adjustement accuracy 0.03% or ±10 mv (20 mv in series) Ripple (mv rms) < 0.7 mv < 0.7 mv < 1.5 mv < 1 mv Pics of commutation (BP 20 MHz) < 15 mvpp < 15 mvpp < 30 mvpp < 30 mvpp Regulation / load 0 to 100% 12 mv 12 mv 24 mv 40 mv Regulation / source ±10% 1 mv 1 mv 2 mv 1 mv Time of answer load 10 to 90% 2 ms 2 ms 2 ms 5 ms Display resolution 10mV 10mV 20mV 10mV Accuracy measurement 0.03% or ±10 mv (20 mv in series) Display 4 digits + parameters on graphic LCD Output current 2 x 0-6 A ± 0-6 A 0-6 A 0-12 A Minimum current 2 ma 2 ma 2 ma 10 ma Adjustement accuracy 0.03% or ±2 ma (10 ma in series) Ripple (marms) <1 ma <1 ma <1 ma <1 ma Regulation / load 0 to 100% 1 ma 1 ma 2 ma 2 ma Regulation / source ±10% 1 ma 1 ma 1 ma 1 ma Display resolution 2 ma 2 ma 2 ma 10 ma Accuracy measurement 0.03% or ±2 ma (10 ma in series) Display 4 digits + parameters on graphic LCD s Against short-circuits, by current regulation. Against overtemperature by fan and thermal circuit-breaker. Against overcurrent on main input, by internal fuses. Various and functions Dispaly : Graphic LCD 128 x 64 pixels with white backlight. Visualization of all parameters (CV, CC, RMT, etc...) Memory : 16, including 15 configurable. OVP/OCP : Against overvoltage and overcurrent, adjustable from 0 to maxi. Functions : 6 available on U or I (Arbitrary, square, rising and falling periodically ramp, rise or fall time single shot). Time adjustement from 10ms to 60mn. Remote sensing : 4 wires mode on the back-side's terminal blocks. Correction of the voltage drop in the wires : 2V Standby : output, enable / disabled and standby of the power supply. Interfaces All the interfaces are insulated of the output (150V max). USB and RS485 are standard. LabVIEW's drivers as a standard. Controller 0 10V : by direct input 0-10V for U for each channel or for U & I for channel 1 or potentiometer 10K or adjustable resistance 10K. In the back side on disconnect scribe terminal blocks. : Class I, enhanced safety between mains input and outputs. Complies with EN , CAT II. CEM : Complies with EN and EN Input voltage : Volts ±10%, 50 / 60Hz. Mains input : socket C14 with C13 2 poles + earth cable removable Power consumption : 475W maxi. Efficiency : > 81% of the maxi powerful. Operating temperature : +5 to +40 C. Coefficient of temperature / C : 0.01% for the voltage and the current. Voltage on the earth : 100V Max. Presentation : Front-panel with sensitiv keypad, rear-panel with handle and cord storage area, metallic case with epoxy finish. 5

3 ADJUSTABLE POWER SUPPLY EAN CODE : TRIPLE AL 936N EASY : Direct digital display of voltage and current, even in the series or parallel mode. SURE : Automatic disconnection each time the master and slave channel configuration is changed. COMPLETE : Third channel with fixed or variable position and voltage or current display. EFFECTIVE : Idc adjustment independent of load. QUIET : Silent temperature-controlled fan cooling. 200 WATTS 2 X 0-30V 0-3A or 1 X ± 0-30V 0-3A or 1 X 0-60V 0-3A or 1 X 0-30V 0-6A + 1 X 2-5,5V 3A or 1 X 5,5-15V 1A % C &! % $ C! $ CHANNELS MASTER AND SLAVE AUXILIARY Configuration Independent Tracking Series Parallel Variable Variable Output voltage 2x 0-30V ± 0-30V 0-60V 0-30V 2-5,5V 5,5-15V Minimum voltage ± 10mV ± 10mV ± 20mV ± 10mV < 2V - Ripple (mv rms) 1mV 1mV 1mV 1mV 1mV 1mV Load regulation from 0 to 100% 12mV 12mV 50mV 24mV 12mV 10mV Line regulation from -6 to +7% 5mV 5mV 5mV 5mV 5mV 1mV Internal resistance 4mΩ 4mΩ 16mΩ 4mΩ 4mΩ 4mΩ Resp. for 10 to 90% load change 30µs 30µs 30µs 30µs 100µs 60µs Display resolution 100mV 100mV 100mV 100mV 10mV 100mV Display 14 mm 3 digit LED digital voltmeter Output current 2x 0-3A ± 0-3A 0-3A 0-6A 3A 1A Minimum current 10mA 10mA 10mA 20mA - - Ripple (ma rms) 1mA 1mA 1mA 4mA - - Load regulation from 0 to 100% 2mA 2mA 4mA 8mA - - Line regulation from -6 to +7% 1mA 1mA 1mA 5mA - - Display resolution 10mA 10mA 10mA 10mA 10mA 10mA Display 14 mm 3 digit LED digital ammeter Power supplies A and B (master and slave) The Standby mode disconnects the output terminals. It is automatic upon a change of mode. The Idc push-button shorts the output in the standby mode. It is used for setting Imax. I ndicators : green LED for voltage regulation red LED for current regulation. Display : automatic display switching depending on selected configuration. AUXILIARY power supply The Display button switches the display between voltage and current. The voltage is continuously adjustable from 2 to 15V. The max current goes from 3A to 1A after 5,5V. Short circuit protection, by current regulation. Overtemperature protection, by temperature-controlled fan, thermal circuit-breaker and relay. T ransformer primary overcurrent protection, by fuse. : Class I, enhanced safety between mains input and outputs. Complies with EN , overvoltage category II, pollution degree 2. Toroidal transformer, class II, complies with EN EMC : Complies with EN , performance criteria B, and EN 55011, ISM Group I, Class B. Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 410 VA. Dielectric strength : 2300V between input, output and chassis. Outputs : safety terminals (VDE 0110 standard and BG certified), and safety inverted earth terminal. Presentation : screen-printed polycarbonate front panel, metalcase, epoxy finish. 7

4 ADJUSTABLE POWER SUPPLY EAN CODE : DOUBLE ALR3003D PRATICAL : Digital display of voltage and current. EASY : Automatic mode select button : separate, tracking and series. PRECISE : Fine voltage adjustment. QUIET : Silent temperature-controlled fan cooling. 180 WATTS 2 X 0-30V 0-3A or 1 X ± 0-30V 0-3A or 1 X 0-60V 0-3A or 1 X 0-30V 0-6A* & $ C! $ & C! $ CHANNELS MASTER AND SLAVE Independent Tracking Series Output Voltage 2x0-30V ± 0-30V 0-60V Minimum Voltage ± 10mV ± 10mV ± 20mV Ripple (mv rms.) 1mV 1mV 1mV Load regulation from 0 to 100% 12mV 12mV 50mV Line regulation from -6 to +7% 5mV 5mV 5mV Internal resistance 4mΩ 4mΩ 16mΩ Resp. for 10 to 90% load charge 30µs 30µs 30µs Dispaly resolution 100mV 100mV 100mV Display 14mm 3 digit LED Voltmeter Output current 2x0-3A ± 0-3A 0-3A Minimum current 10mA 10mA 10mA Ripple (ma rms.) 1mA 1mA 1mA Load regulation from 0 to 100% 2mA 2mA 4mA Line regulation from -6 to +7% 1mA 1mA 1mA Dispaly resolution 10mA 10mA 10mA Display 14mm 3 digis LED Ammeter : Class I, enhanced safety between mains input and outputs. Complies with EN , overvoltage category II, pollution degree 2. Toroidal isolation transformer, class II, complies with EN EMC : Complies with EN , performance criteria B, and Power Supplies A and B (master and slave) The "Tracking/Series" mode internally connects the - terminals of the master and + terminals of the slave (mid point). All adjustments are made from the slave power supply. The parallel mode* (external connection) provides up to 6 amperes. Indicators : green LED for voltage regulation red LED for current regulation. Display of voltage and current on 14 mm 3 digit red LED displays. Short circuit protection, by current regulation. Overtemperature protection, by temperature-controlled fan, thermal circuit-breaker and relay. T ransformer primary overcurrent protection, by fuse. Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 400 VA. Dielectric strength : 2300V between input, output and chassis. Outputs : Presentation : safety sockets and safety inverted earth socket. screen-printed polycarbonate front panel, meta case, epoxy finish. 8

5 ADJUSTABLE POWER SUPPLY EAN CODE : SIMPLE AL 924A PRACTICAL : Digital display of voltage and current. PRECISE : Coarse and fine voltage adjustment. - Adjustable current from 0 to 10A or 0 to 1A. USEFUL : Automatic constant voltage or current operation. PROTECTED : Short circuit protection. ' &!! $ 300 WATTS 0-30V 0-10A & C $ C Voltage Floating outputs on 4 mm safety terminals. Automatic constant voltage operation. Adjustable from 0 to 30V (0 to + or -5mV) with fine adjustment (about 2 Volts). Regulation : < 40mV for a load variation from 0 to 100%. < 25mV for a 10% line variation. Ripple : < 3 mv peak to peak or 1 mv rms. Internal resistance: < 4 mω. Indicator : green LED for voltage regulation. Display : 14mm 3 digit LED digital voltmeter. Resolution : 100 mv. Automatic constant current operation. Two selectable current ranges : 10A or 1A. Adjustable from 0 to 10A or from 0 to 1A, depending on the selected range. Regulation : < 10 ma for a 10% line charge. < 20 ma for a load change from 0 to 100%. Ripple : < 10 ma peak to peak or 3,5 ma rms. Indicators : red LED for current regulation. Display : 14 mm 3 digit LED digital ammeter. Resolution : 10 ma on 1A range, 100 ma on 10A range : Class I, enhanced safety between mains input and outputs. Complies with EN , overvoltage category II, pollution degree 2. EMC : Complies with EN , performance criteria B, and Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 620 VA. Dielectric strength : 2300V from input to output, 1350V from input to chassis. Outputs : safety terminals (VDE 0110 standard and BG certified), and safety inverted earth terminal. Presentation : screen-printed polycarbonate front panel, metal case, epoxy finish. Short circuit protection, by current regulation. Overtemperature protection, by fan, by thermal circuit-breaker and by relay on the transformer. Transformer primary overcurrent protection, by fuse. 9

6 ADJUSTABLE POWER SUPPLY EAN CODE : SIMPLE AL 781NX PRACTICAL : Digital display of voltage and current. PRECISE : Coarse and fine voltage adjustment. - Adjustable current from 0 to 5A or 0 to 1A. USEFUL : Automatic constant voltage or current operation. PROTECTED : Short circuit protection. ' &!! $ 150 WATTS 0-30V 0-5A & " C ' C Voltage Floating outputs on 4 mm safety terminals. Automatic constant voltage operation. Adjustable from 0 to 30V (0 to + or -5mV) with fine adjustment (about 2,5 Volts). Regulation : < 20mV for a load variation from 0 to 100%. < 15mV for a 10% line variation. Ripple : < 3 mv peak to peak or 1 mv rms. Internal resistance : < 4 mω. Indicators : green LED for voltage regulation. Display : 14mm 3 digit LED digital voltmeter. Resolution : 100 mv. Automatic constant current operation. Two selectable current ranges : 5A or 1A. Adjustable from 0 to 5A or from 0 to 1A, depending on the selected range. Regulation : < 10 ma for a 10% line charge. < 15 ma for a load change from 0 to 100%. Ripple : < 6 ma peak to peak or 2,1 ma rms. Indicators : red LED for current regulation. Display : 14mm 3 digit LED digital ammeter. Resolution : 10 ma. : Class I, enhanced safety between mains input and outputs. Complies with EN , overvoltage category II, pollution degree 2. EMC : Complies with EN , performance criteria B, and Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 315 VA. Dielectric strength : 2300V from input to output, 1350V from input to chassis. Outputs : safety terminals (VDE 0110 standard and BG certified), and safety inverted earth terminal. Presentation : screen-printed polycarbonate front panel, metal case, epoxy finish. Short circuit protection, by current regulation. Overtemperature protection, by thermal circuit-breaker and by relay on the transformer. Transformer primary overcurrent protection, by fuse. 10

7 ADJUSTABLE POWER SUPPLY EAN CODE : SIMPLE ALR3003 PRACTICAL : Digital display of voltage and current. - Cord housing. PRECISE : Coarse and fine voltage adjustment. USEFUL : Automatic constant voltage or current operation. PROTECTED : Short-circuit protection. QUIET : Controlled fan cooling.!!! & & 90 WATTS 0-30V 0-3A '! C! ' Voltage Automatic constant voltage operation. Adjustable from 0 to 30 Volts (0 to ± 10 mv) with fine adjustment (about 2 Volts). Regulation : < 12 mv for a load variation from 0 to 100%. < 5 mv for a line variation of 10%. Ripple : < 3 mv peak to peak or 1 mv rms. Internal resistance : < 4 mω. Display : 14 mm 3 digits LED digital voltmeter. Resolution : 100 mv Automatic constant current operation. Adjustable from 0 to 3 Amps. Regulation : < 1 ma for a line charge of 10 %. < 2 ma for a load charge from 0 to 100%. Ripple : < 1 ma rms. Display : 14 mm 3 digits LED digital ammeter. Resolution : 10 ma : Class II, Safety Extra Low Voltage (SELV) outputs with insulation enhanced transformer. Complies with EN , overvoltage category II, pollution degree 2. EMC : Complies with EN , performance criteria B, and level : IP 21. Input voltage : 230 V ±10%, 50 / 60 Hz. Main input : Cord with 2 poles immovable. Power consumption : 176 VA max. Dielectric strength : 3000 V between the input and the output. Presentation : screen-printed polycarbonate front panel, metal case with cord housing, epoxy finish. s Short-circuit protection by current regulation. Overtemperature protection by temperature-controlled fan, relay and thermal circuit-breaker. Transformer primary and secondary overcurrent protection by fuse. 11

8 ADJUSTABLE POWER SUPPLY EAN CODE : TRIPLE + INTERFACES AL 991S COMPLETE : Three outputs available simultaneously. PRATICAL : Digital voltage display. USEFUL : Setting memory. COMPATIBLE : RS232, USB* and LABVIEW interfaces. PROTECTED : Short circuit protection. 48 WATTS RS232 + LABVIEW + USB* 0 to ± 15V 1A or 0 to 30V 1A and 2 to 5,5V 3A and -15 to +15V 0,2A LabVIEW ' $! C *OPTION : USBRS232! $ Voltage Three outputs available simultaneously : - Power supply A : adjustable from 0 to ±15 Volts balanced. or 0 to 30V with the -15V terminal as reference. - Power supply B: adjustable from + 2 to + 5,5 Volts. - Power supply C: adjustable from - 15 to + 15Volts. Voltage adjustment : push-button selection of output A, B or C. Voltage incremented and decremented by four push-buttons : -1 V + 1 V - 0,1 V + 0,1V Automatic storage of the three voltage settings. Regulation : < 20mV for a load variation from 0 to 100%. < 10mV for a 10% line variation. Ripple : < 3 mv peak to peak or 1 mv rms. I ndicators : Three red LEDs showing the selected output for display and adjustment. Display : 14 mm 3 digit LED digital voltmeter for the three outputs. Resolution : 100 mv. EMC : Class I, enhanced safety between mains input and outputs. Complies with EN , overvoltage category II, pollution degree 2. : Complies with EN , performance criteria B, and Mains input : Socket C14 with C13 removable cable (2 poles + earth). s Max I : 1A on output A. 3A to 5,5 Volts and 1,5A to 2 Volts on output B. 0,2A on output C. Display : limiting on one output causes the display to blink ; it shows : Ic.A, Ic.b, Ic.C or +Ic, depending on the overloaded output(s). Short circuit protection, by current limit. Transformer primary overcurrent protection, by fuse. Chassis ground output on 4 mm inverted safety socket. Interface RS-232 link, 9-way male SUB-D plug. USB option: Kit includes an adaptator null modem und RS232 cable Software LG991S for Windows95* or + LG991S LV and base VI under LabVIEW** Softwares are available for download on website (*is a registered trademark of Microsoft Co.) (** (*is a registered trademark of National Instruments.) Power consumption : 100 VA max. Dielectric strength : 2300V from input to output, 1350V from input to chassis. Presentation : screen-printed polycarbonate front panel, metal case, epoxy finish. 12

9 ADJUSTABLE & MULTIPLE POWER SUPPLY EAN CODE : DOUBLE AC/DC ALR3002M COMPLETE : DC and AC voltages available simultaneously. POWERFUL : generator. PRACTICAL: No common reference. - Cord housing. PROTECTED : The DC output is protected by current regulation. - The AC outputs are protected by auto reset thermal circuit-breakers. 120 WATTS 0-5, 6, 12 or 30V 0-25mA, 250mA or 2,5A DC and 6 or 12 or 24V 5A AC! & &!! ' " " C DC outputs Automatic constant voltage operation. Four choices of voltage ranges with adjustement by trimer from 0 to max : 0 to 5V, 0 to 6V, 0 to 12V or 0 to 30V. Regulation : < 10 mv for a load variation from 0 to 100%. < 5 mv for a line variation from -6 +7%. Ripple : < 3 mv peak to peak or 1mV rms. Internal resistance : < 5 mω. Display : 14mm 3 digits LED digital voltmeter. Resolution : 10mV for 5 and 6V and 100 mv for 12 and 30V. Automatic constant current operation. Three choices of current ranges with adjustement by trimer from 0 to max : 0 to 25mA ; 0 to 250mA ; 0 to 2,5 Amps. Regulation : < 2 % for a load change from 0 to 100%. Ripple : < 1 ma rms. Display : 14mm 3 digits LED digital ammeter. Resolution : 100µA on 25mA range, 1mA on 250mA range, 10mA on 2,5A range. s Short circuit protections by current regulation. Overtemperature protection by transformer secondary switching relay and thermal circuit-breakers. Transformer primary overcurrent protections by fuse. AC outputs Three outputs with common point. Voltages : 6 Volts, 12 Volts and 24 Volts. No-load voltage 5% maximum above rated voltage. Max I : 5 Amps on 6,12, or 24V. s Secondary overcurrent protection by auto-reset thermal circuit-breakers. Precautions The AC and DC circuits can be used simultaneously but with a max power of 120W. EMC : Class II, Safety Extra Low Voltage (SELV) outputs with insulation enhanced transformer. Complies with EN , overvoltage category II, pollution degree 2. : Complies with EN , performance criteria B, and level : IP 21. : Transformer primary overcurrent protection, by fuse. Main input : 2 poles cable immovable. Power consumption : 250 VA max. Dielectric strength : 3000V from input to output. Presentation : screen-printed polycarbonate front panel, metal case with cord housing, epoxy finish. 13

10 MULTIPLE POWER SUPPLY EAN CODE : DOUBLE AC/DC AL 843A COMPLETE : DC and AC voltages available simultaneously. PRACTICAL : No common reference. PROTECTED : The DC output is protected by fold-back current limiting. The AC outputs are protected by auto-reset thermal circuit-breakers. 120 WATTS 6 or 12V 10A or 24V 5A DC and AC $ & % " C! & C! $ DC outputs Three switchable outputs : 6V, 12V or 24V. Accuracy : ± 1% Regulation : < 40 mv at 6 and 12 V outputs for a load variation from 0 to 100%. < 20 mv at 24 V output for a load variation from 0 to 100%. Ripple : < 5 mv peak to peak or 1,8 mv rms. Internal resistance : < 4 mω. Max I : 10A at 6 or 12V output. 5A at 24V output. Short circuit protection by fold-back current limit, allowing continuous short circuit without overheating. AC outputs Three outputs with common point. Voltages : 6 Volts, 12 Volts and 24 Volts ± 10%. No-load voltage 5% maximum. Max I : 10A at 6 and 12V outputs. 5A at 24V output. Secondary overcurrent protection by auto-reset thermal circuit-breakers. Precautions The AC and DC circuits can be used simultaneously but with a max power of 120W. EMC : Class I, enhanced safety between mains input and outputs. Complies with EN , overvoltage category II, pollution degree 2. : Complies with EN , performance criteria B, and Transformer primary overcurrent protection, by fuse. Mains input : Socket C14 with C13 removable cable (2 poles + earth). Power consumption : 250 VA max. Dielectric strength : 3700V from input to output, 2200V from input to chassis. Presentation : screen-printed polycarbonate front panel, metal case, epoxy finish. 14

11 MULTIPLE POWER SUPPLY EAN CODE : DOUBLE AC/DC AM COMPLETE : DC and AC voltages available simultaneously. PRACTICAL : No common reference. - AC and DC power-on indicators. PROTECTED : The DC output is protected by current regulation. - The AC outputs are protected by auto-reset thermal circuit-breakers. 120 WATTS 6 or 12V 5A DC and AC C $ ' " C $ DC outputs Two switchable outputs : 6 Volts or 12 Volts. Accuracy : ± 1% Regulation : < 20mV for a load variation from 0 to 100%. < 5mV for a 10% line variation. Ripple : < 3 mv rms including : <3mV peak to peak of the signal at 100 KHz <4mV peak to peak of the signal at 100 Hz <12mV peak to peak of switching peak Hold up time : 25ms at half load and 12ms at full load (190V line input). Indicator : green power-on LED indicator. Max I Idc : 5A at 6 or 12V output. : 5,5A. Short circuit protection by current limiting, Overcurrent protection on source by fuse on main input AC outputs Two outputs with common point. Voltages : 6 Volts and 12 Volts + or - 5%. No-load voltage 10% maximum. Indicator: green power-on LED indicator. Max I : 5A at 6V or 12V output. Short circuit and overcurrent protection by auto-reset thermal circuit-breakers. Precautions Power supply max. power is of 120 Watts The AC and DC circuits can be used simultaneously. EMC Input voltage Mains input : Class II, double insulation Complies with EN , overvoltage category II, pollution degree 2. : Complies with EN , performance criteria B, and : 230V ±10%, 50 / 60 Hz. : C8 socket with CEI320 C7 removable cable (2 poles double insulation). Power consumption : 145 VA max. : against overcurrent at the input by fuse level : IP 30 Dielectric strength : 3000V between input to output. Presentation : Metal case with epoxy finish 15

12 AC POWER SUPPLY & DC RECTIFIER EAN CODE : DOUBLE AC/DC AM COMPLETE : DC rectified and AC voltages available simultaneously. PRACTICAL : AC and DC power-on indicators. PROTECTED : The DC rectifier output and the AC outputs are protected by auto-reset thermal circuit-breakers. 120 WATTS 6V 20A 12V 10A DC and AC " C "! C ' $ DC outputs Two switchable outputs : 6 Volts or 12 Volts. Voltage rectified only Indicator : green power-on LED indicator. Max I : 20A at 6V output. : 10A at 12V output Short circuit protection by current limiting, Overcurrent protection on source by fuse on main input AC outputs Two outputs with common point. Voltages : 6 Volts and 12 Volts + or - 5%. No-load voltage 10% maximum. Indicator: green power-on LED indicator. Max I : 20A at 6V output. or 10A at 12V output Short circuit and overcurrent protection by auto-reset thermal circuit-breakers. Precautions Power supply max. power is of 120 Watts The AC and DC outputs can be used simultaneously on circuits without common refrence. EMC Input voltage Mains input : Class II, double insulation Complies with EN , overvoltage category II, pollution degree 2. : Complies with EN , performance criteria B, and : 230V ±10%, 50 / 60 Hz. : double insulation cord with 2 poles immovable. Power consumption : 145 VA max. : against overcurrent at the input by fuse level : IP 30 Dielectric strength : 3000V between input to output. Presentation : Metal case with epoxy finish 16

13 UNIVERSELLE BENCH POWER SUPPLY EAN CODE : UNIVERSAL AL 841C UNIVERSAL : Choice of six voltages. PRACTICAL : ON/OFF switch. - Power-on indicator. PROTECTED : Short circuit protection. RESISTANT TO SHOCK : Polycarbonate case 12 WATTS 3 / 4,5 / 6 / 7,5 / 9 or 12V 1A ' ' $ % C &! & Voltage Output voltage : 3 V or 4,5 V or 6 V or 7,5 V or 9 V or 12 V selectable Accuracy : ± 4%. Regulation : < 20mV for a load variation from 0 to 100%. < 15mV for a 10% line variation. Ripple : 5 mv peak to peak or 1,8 mv rms. Internal resistance : < 20 mω. The max current is constant and independent of the selected output. Max I : 1 A. Indicator Green power-on LED indicator. : Class II - Safety Extra Low Voltage (SELV) output Complies with EN , overvoltage category II, pollution degree 2. EMC : Complies with EN , performance criteria B, and Mains input : C8 socket with CEI320 C7 removable cable (2 poles double insulation). ON/OFF control : toggle switch. Power consumption : 30 VA max. Dielectric strength : 3000Vac from input to output. Presentation : Polycarbonate case screen-printed. Short circuit protection, by current limit. Transformer primary overcurrent protection, by fuse. 27

14 SYMMETRIC BENCH POWER SUPPLY EAN CODE : V or 12V or 24V ALF1501D PRATICAL : ON/OFF switch. - Power-on indicator W available on the positive output alone. PRECISE : Output ripple < 3mV rms. - Output voltage adjustable from ±10 to ±15V. PROTECTED : against Short circuit. RESISTANT TO SHOCK 30 WATTS +/- 10 to 15V 1A or 12V 2,5A or 24V 1A ' ' $ C &!! ' Balanced-output power supply with common 0V. Floating outputs on 4-mm safety sockets. Ajustable output voltages : from ±10 to ±15V +15V output Regulation : < 15mV for a load variation from 0 to 100%. < 2mV for a line variation from 198 to 264 V. Ripple : < 3mV rms including : < 3mV peak to peak of switching signal < 8mV peak to peak of the signal at 100Hz < 10mV peak to peak of switching spikes -15V output Regulation : < 10mV for a load charge from 0 to 100%. < 2mV for a line charge from 198 to 264 V. Ripple : < 3mV rms including : < 2mV peak to peak of switching signal < 4mV peak to peak of the signal at 100Hz < 15 mv peak to peak of switching spikes 24V Output (Adjustable from 20 to 30V) Available between output + and - Regulation : < 15mV for a load charge from 0 to 100% < 2mV for a line charge from 198 to 264V Ondulation : < 5mV rms including: < 3mV peak to peak of the switching signal < 12mV peak to peak of the signal at 100Hz < 30mV peak to peak of switching spikes Indicators 2 Green +15V and -15V power-on LED indicator. +15V (alone) I max : 3A at 10V 2,5A at 12V 2A at 15V -15V (alone) I max : 1,1A in short-circuit condition 1A from 10 to 15V 24V (Adjustable from 20 to 30V) I max : 1A from 20 to 30V Power Max output power : 30W. I max ±15V : 1A s Against short-circuits by current limit and disjunction. Against overcurrent on source by fuse. : Class II, Safety Extra Low Voltage (SELV) Complies with EN , overvoltage category II, pollution degree 2. EMC : Complies with EN , performance criteria B, and level : IP30. Operating temperature : 5 to 40 C Input voltage : 198 to 264 V, 50 / 60 Hz. Mains input : C8 socket with CEI320 C7 removable cable (2 poles double insulation). Power consumption : 40W max. ON/OFF control : toggle switch Dielectric strength : 3000 V between input to output. Presentation : polycarbonate case screenprinted. 29

15 SYMMETRIC POWER SUPPLY EAN CODE : V or 12V or 24V ALF1502D PRATICAL : ON/OFF switch. - Power-on indicator W available on the positive output alone. PRECISE : Output ripple < 3mV rms. - Output voltage adjustable from ±10 to ±15V. PROTECTED : against Short circuit. RESISTANT TO SHOCK 60 WATTS +/- 10 to 15V 2A or 12V 5A or 24V 1A ' ' $! C &! " $ Balanced-output power supply with common 0V. Floating outputs on 4-mm safety sockets. Ajustable output voltages : from ±10 to ±15V. +15V output Regulation : < 15mV for a load variation from 0 to 100%. < 2mV for a line variation from 198 to 264 V. Ripple : < 3mV rms including : < 3mV peak to peak of switching signal < 5mV peak to peak of the signal at 100Hz < 15mV peak to peak of switching spikes -15V output Regulation : < 30mV for a load variation from 0 to 100%. < 2mV for a line variation from 198 to 264 V. Ripple : < 3mV rms including : < 4mV peak to peak of switching signal < 4mV peak to peak of the signal at 100Hz < 15 mv peak to peak of switching spikes 24V Output (Adjustable from 20 to 30V) Available between output + and - Regulation : < 15mV for a load variation from 0 to 100% < 2mV for a line variation from 198 to 264V Ondulation : < 3mV rms including: < 5mV peak to peak of the switching signal < 8mV peak to peak of the signal at 100Hz < 25mV peak to peak of switching spikes Indicators Green power-on LED indicator. Overheat or overcurent red LED "status" indicator. +15V (alone) I max : 5,5A on the short-circuit 5A from 10 to 12V 4A at 15V -15V (alone) I max : 2,1A in short-circuit condition 2A from 10 to 15V 24V (Adjustable from 20 to 30V) I max : 2,1A at the short circuit 2A from 20 to 30V Power Max output power : 60W. I max ±15V : 2A s Against short-circuits by current limit. Against overcurrent on source by fuse. Overtemperature protection by thermal circuit-breaker : Class II, Safety Extra Low Voltage (SELV) Complies with EN , overvoltage category II, pollution degree 2. EMC : Complies with EN , performance criteria B, and level : IP30. Operating temperature : 5 to 40 C Input voltage : 198 to 264 V, 50 / 60 Hz. Mains input : C8 socket with CEI320 C7 removable cable (2 poles double insulation). Power consumption : 78W max. ON/OFF control : toggle switch Dielectric strength : 3000 V between input to output. Presentation : polycarbonate case screenprinted. 31

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V Sorensen XG Series / XTR Series 670 850 W 850 W, 1U Half Rack Programmable DC Power Supplies 6 600 V Highest Power Density Comprehensive Digital and Analog Interface Options Scalable, Multi-Unit Design

More information

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance

More information

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual Digital-Control and Programmable DC Power Supply Models: 72-2535, 72-2540, 72-2545, 72-2550 & 72-10480 User Manual Page 19/05/16 V1.0 Safety Symbols This chapter contains important safety instructions

More information

Powerful Solutions DHP - Introduction

Powerful Solutions DHP - Introduction Powerful Solutions DHP - ntroduction DHP - DC High Power Programmable Supply he DHP Family contains over 140 Tmodels ranging in output power from 2 kw to 30 kw in a single chassis. The 2 kw and 3 kw models

More information

KEPCO Will Point You In The Right Direction!

KEPCO Will Point You In The Right Direction! Looking For A High Power, Low Profile Power Supply? KEPCO Will Point You In The Right Direction! -9 AN ISO 900 COMPANY You'll Always Find What You Need At Kepco KLN Series Programmable Power Supply: 0W

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

BLU SERIES Battery Load Units

BLU SERIES Battery Load Units BLU SERIES Battery Load Units Lightweight starting from 12,8 kg (28.2 lbs) Powerful discharge power of up to 28,4 kw Voltage measurement range: 5,25-500 V DC Discharge current up to 340 A DC Easily expandable

More information

Induction Power Supplies

Induction Power Supplies Induction Power Supplies 7.5kW; 135 400kHz 480V version (Integral Heat Station) User s Guide Model 7.5-135/400-3-480 SMD Control Brds Rev. D 5/08 Table of Contents 1. Specifications and features...3 2.

More information

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

LAVOLTA DC REGULATED POWER SUPPLY BPS-305 LAVOLTA DC REGULATED POWER SUPPLY BPS-305 USER MANUAL 1 In order to use the power supply better, please read the user manual carefully before using and keeping it properly. Warning: Do not connect any

More information

VSD Series II Variable Speed Micro Drives

VSD Series II Variable Speed Micro Drives VSD Series II Variable Speed Micro Drives Product Bulletin Code No. LIT-12011813 Issued March 26, 2013 Refer to the QuickLIT website for the most up-to-date version of this document. Johnson Controls VSD

More information

Low Profile DC Power Supply with Zero Voltage Soft Switching

Low Profile DC Power Supply with Zero Voltage Soft Switching Sorensen XFR Series Low Profile DC Power Supply with Zero Voltage Soft Switching Analog programming Zero voltage soft switching Constant voltage or constant current operation with automatic crossover and

More information

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual USER MANUAL IPS home inverters with UPS function Suitable for UPS: - IPS300-SIN - IPS300-SIN-WM - IPS300-SIN-DC - IPS600-SIN - IPS600-SIN-WM - IPS600-SIN-DC - IPS1000-SIN - IPS1000-SIN-DC - IPS1600-SIN

More information

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction Technical brochure The Vector series The ABB comprehensive solution for automatic power factor correction 2 Applications The Vector series The Vector series The Vector series is a powerful and compact

More information

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant. Advantages of the 72 Alternating Relay The Complete System Solution! Highest Grade Electronic Components RoHS Compliant. The Model 72 series Alternating Relay is designed for duplex pumping systems where

More information

PRODUCTS: POWER SUPPLY

PRODUCTS: POWER SUPPLY PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER

More information

MCD 200 Series Soft Starters

MCD 200 Series Soft Starters MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1 SPECIFICATION FSP350-60APN(85) Bronze (Erp2013) DATE:MAY, 14, 2013 REV:2 表單編號 :7000P-0105 Page1 TABLE OF CONTENTS PAGE 1. GENERAL REQUIREMENTS 3 2. INPUT REQUIREMENTS 3 3. OUTPUT REQUIREMENTS 3 3.1 Output

More information

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM 2 Table of Contents Introduction:... 3 1.0: Operation Principles:... 3 1.1: Stand alone supply... 3 1.2: Backed up supply:... 3 1.3: Battery

More information

Model 1672, 1673 Triple Output Power Supply

Model 1672, 1673 Triple Output Power Supply Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases

More information

SYMBOL PARAMETER FOR BOOST CONVERTER CONDITIONS MIN TYP MAX UNITS

SYMBOL PARAMETER FOR BOOST CONVERTER CONDITIONS MIN TYP MAX UNITS DEMO CIRCUIT 383B QUICK START GUIDE LT1930ES5/LT1931ES5 1.2MHz, SOT-23 DC/DC CONVERTER DESCRIPTION Demonstration Circuit 383B is multipurpose demonstration board featuring the LT1930 and LT1931. The demo

More information

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC The Z Series Zero-Fired SCR Power Controllers 60-1200 AMPS 120-600 VAC SCR Power controllers for resistance heating applications. ROBICON 1996 Rev. 7/96 Applications Robicon s Z series power controls are

More information

Declaration of Conformity

Declaration of Conformity Declaration of Conformity We GOOD WILL INSTRUMENT CO., LTD. No. 95-11, Pao-Chung Rd., Hsin-Tien City, Taipei Hsien, Taiwan GOOD WILL INSTRUMENT (SUZHOU) CO., LTD. No.69 Lushan Road, Suzhou New District

More information

Low Amp Probe EETA308A

Low Amp Probe EETA308A Low Amp Probe EETA308A Reference Manual First Edition SAFETY WARNING DO NOT APPLY OVER 150V AC (RMS) OR DC. DISCONNECT LEADS BEFORE REMOVING THE BATTERY COVER. DO NOT ALLOW THE CABLE TO BECOME ENTANGLED

More information

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

SINUS PENTA 2T/4T SINUS PENTA 2T/4T SINUS PENTA 2T/4T SINUS PENTA 2T/4T Technical Highlights One product, 5 integrated functions - IFD (Inverter Frequency Drive): vector modulation function for general-purpose applications (V/F pattern).

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

Variable speed application guidelines

Variable speed application guidelines Variable speed application guidelines Frequency converter VLT 00 SCROLL COMPRESSORS REFRIGERATION AND AIR CONDITIONING www.danfoss.com Introduction The introduction of speed control for refrigeration

More information

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Technical data. Miniature Circuit Breakers. System pro M. System pro M Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten

More information

Technical Data Sheets

Technical Data Sheets Digit al Energy T M L P Seri es Di gi ta l Energy TM LP Series Digita l Energ y T M L P Se rie s GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 25W 350 1050mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter Go Power! Manual GP-1750HD Inverter GP-2500 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION...

More information

Power you can rely on

Power you can rely on Master series Power you can rely on High-quality battery chargers and inverters Lightweight High effi ciency Easy to install Mastervolt for the road Mastervolt paves the way to a system without weak links,

More information

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443 CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters

More information

Sola 3000 Guide Specifications

Sola 3000 Guide Specifications Sola 3000 Guide Specifications CSI 16610 - Static Uninterruptible Power Supply Systems - Sola 3000 Guide Specifications for a 700 to 2200 VA Single - Phase Uninterruptible Power Supply System 1.0 GENERAL

More information

Rental Power QSL9 series engine

Rental Power QSL9 series engine Specification sheet Rental Power QSL9 series engine 250 kva - 300 kva 50 Hz 225 kw - 275 kw 60 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing

More information

Electronics. Voltage Converters 132. RCD/GPO Inverters 135. Pure Sine Wave Inverters 136. Combi Inverter/Chargers 138. AC to DC Battery Chargers 140

Electronics. Voltage Converters 132. RCD/GPO Inverters 135. Pure Sine Wave Inverters 136. Combi Inverter/Chargers 138. AC to DC Battery Chargers 140 Voltage Converters 132 RCD/GPO Inverters 135 Pure Sine Wave Inverters 136 Combi Inverter/Chargers 138 AC to DC Battery Chargers 140 DC to DC Battery Chargers 141 Power Supplies 142 Battery Monitor 144

More information

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS RELIABLE SOLUTIONS in POWER ELECTRONICS Power Management Instruments DC Battery Charger / Automation Type Distributed by : nonstopower sdn bhd (822490-P) no. 78 & 80, jalan rimbunan raya, laman rimbunan,

More information

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output 750W PowerVerter RV Inverter/Charger with Hardwire Input/Output MODEL NUMBER: RV750ULHW Highlights 12V DC or 120V AC input; 120V AC output (hardwired) 750 watts continuous, 1125 watts OverPower and 1500

More information

APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction

APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction APC03 series provides the ideal power factor correction solution for industrial and commercial applications.

More information

Diesel Generator set QSK95 series engine

Diesel Generator set QSK95 series engine Specification sheet Diesel Generator set QSK95 series engine 2600 kva-3750 kva Emissions regulated Description Cummins commercial generator sets are fully integrated power generation systems providing

More information

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System Datasheet 1291BL Series Technical Specification Single-Axis Rate and Positioning Table System DESCRIPTION The Model 1291BL Single Axis Positioning and Rate Table System is designed to provide precise position,

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

Digital Insulation Resistance Testers. you can depend on

Digital Insulation Resistance Testers. you can depend on Digital Insulation Resistance Testers you can depend on Fluke 1550 MegOhmMeter Digital insulation testing up to 5000 Volts The Fluke 1550 is a digital insulation tester capable of testing switchgear, motors,

More information

Rev1.0 UCT V 1A Standalone Linear Li-ion Battery Charger GENERAL DESCRIPTION FEATURES APPLICATIONS

Rev1.0 UCT V 1A Standalone Linear Li-ion Battery Charger GENERAL DESCRIPTION FEATURES APPLICATIONS 5V 1A Standalone Linear Li-ion Battery Charger GENERAL DESCRIPTION The UCT3146 is a highly integrated 5V 1A Li-ion battery linear charging management device. The UCT3146 charges a battery in three phases:

More information

MIT300 Series Insulation and Continuity Testers

MIT300 Series Insulation and Continuity Testers MIT300_UG_en_V11.qxp 14/1/09 3:03 pm Page 1 M MIT300 Series Insulation and Continuity Testers Megger MIT300-EN MIT 300 EN Insulation Resistance Continuity Tester Megger MIT310A-EN MIT 310A EN Insulation

More information

Diesel Generator set QSK95 series engine

Diesel Generator set QSK95 series engine Specification sheet Diesel Generator set QSK95 series engine 2500 kw-3500 kw EPA Tier 2 emissions regulated Description Cummins commercial generator sets are fully integrated power generation systems providing

More information

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 SECTION 1. 600V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 Soft Starters SECTION 2. LIQUID COOLED VFD I 3 Liquid Cooled

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT30K Highlights On-line double-conversion topology, VFI operation

More information

ALPHA S NEXT-GENERATION UNINTERRUPTIBLE POWER SUPPLY

ALPHA S NEXT-GENERATION UNINTERRUPTIBLE POWER SUPPLY ALPHA S NEXT-GENERATION UNINTERRUPTIBLE POWER SUPPLY next-generation power From ground-breaking transformer design to the most intuitive and user-friendly interface in the industry, the XM3-HP sets the

More information

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Features and functions Power supply Standard

More information

User Manual. Hybrid PV Inverter. Version: 2.1

User Manual. Hybrid PV Inverter. Version: 2.1 User Manual Hybrid PV Inverter Version: 2.1 Table Of Contents 1. Introduction...1 2. Important Safety Warning...2 3. Unpacking & Overview...4 3-1. Packing List... 4 3-2. Product Overview... 4 4. Installation...5

More information

PRE-HEAT & POST WELD HEAT TREATMENT EQUIPMENT & ACCESSORIES

PRE-HEAT & POST WELD HEAT TREATMENT EQUIPMENT & ACCESSORIES PRE-HEAT & POST WELD HEAT TREATMENT EQUIPMENT & ACCESSORIES STATE OF THE ART TECHNOLOGY MARITIME STRESS IS COMMITTED TO PROVIDING HIGH QUALITY PRODUCTS AT COMPETITIVE PRICES. Page 2 Since the establishment

More information

Micro Family 300V Input

Micro Family 300V Input Actual size: 2.28 x 1.45 x 0.5in [57,9 x 36,8 x 12,7mm] Micro Family 300V Input C US C NRTL US DC-DC Converter Module S Features & Benefits DC input range: 180 375V Isolated output Input surge withstand:

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:

More information

J1000 D E F I 1000 J1000 J1000 J1000 J1000

J1000 D E F I 1000 J1000 J1000 J1000 J1000 Compact Inverter SERIES J1000 GB D E F I 1000 J1000 J1000 J1000 J1000 The J-Type YASKAWA Inverter Drive Technology Contents Page 2 Experience & Innovation A leader in Inverter Drives technology Page 3

More information

N Daily Weekly Monthly Every 3 months. Every 6 months 1 Remove any materials not related

N Daily Weekly Monthly Every 3 months. Every 6 months 1 Remove any materials not related MV / LV cabins maintenance The operation and maintenance of the cabins are meant to ensure high reliability (i.e. the early detection of anomalies, the failure prevention and monitoring functional) and

More information

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data TC2000 TC2001 EUROTHERM ONTROLS Two phase thyristor power switches Product data TC2000 TC2001 Thyristor power switches Compact, two phase thyristor power switches for electrical heating applications from

More information

RT2DB Excitation and voltage regulation system for synchronous generators

RT2DB Excitation and voltage regulation system for synchronous generators s RT2DB Excitation and voltage regulation system for synchronous generators Fully digital. Parameter settings done by software. Self monitoring routines. Maintenance free. High reliability. Excellent dynamic

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

Brake Chopper BC BC 4.1. Instruction and Operation Manual

Brake Chopper BC BC 4.1. Instruction and Operation Manual Brake Chopper BC 2.1 - BC 4.1 Instruction and Operation Manual Caution: There is always a risk involved in the handling of electrical machinery! Therefore mounting and maintenance should only be done by

More information

DEEP SEA ELECTRONICS PLC DSE6010 MKII & DSE6020 MKII Operator Manual

DEEP SEA ELECTRONICS PLC DSE6010 MKII & DSE6020 MKII Operator Manual DEEP SEA ELECTRONICS PLC DSE6010 MKII & DSE6020 MKII Operator Manual Document Number: 057-230 Author: Mark Graham 057-230 IS 057-230 ISSUE: 1 DEEP SEA ELECTRONICS PLC Highfield House Hunmanby North Yorkshire

More information

International Product & Parts Catalog

International Product & Parts Catalog 2011 International Product & Parts Catalog The Powerful Difference Table of Contents About Magnum... 1 Renewable Energy and Magnum Products... 2 Marine Applications and Magnum Products... 3 Caravans and

More information

Kelly KBS Brushless Motor Controller User s Manual

Kelly KBS Brushless Motor Controller User s Manual Kelly KBS Brushless Motor Controller User s Manual Devices Supported: KBS24051L KBS24101L KBS24121L KBS36051L KBS36101L KBS48051L KBS48101L KBS48121L KBS72051L KBS72101L KBS72121L KBS24051X KBS24101X KBS24121X

More information

Low voltage AC drives

Low voltage AC drives General machinery drives Main features and dimensions Unique features Fast and extensive I/O PID control Application macros Many installation possibilities 200 to 480 V, 1-phase or 3-phase More value for

More information

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B Solid State Relays SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B AC semiconductor contactor Zero switching (RJ1A) or instant-on switching (RJ1B) Direct copper bonding (DCB) technology LED-indication

More information

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA P Temperature monitoring (PTC) Short-circuit monitoring Supply voltage 24-240 V AC/DC 1 normally open contact Width 22,5 mm Status indication LED U: Supply voltage LED TFailure: Temperature failure TECHNICAL

More information

& Operation Manual. Growatt 10000HY. Installation GR-UM-A03-A-00

& Operation Manual. Growatt 10000HY. Installation GR-UM-A03-A-00 Growatt 10000HY Installation & Operation Manual GROWATT NEW ENERGY TECHNOLOGY Co.,LTD No.28 Guangming Road, Shiyan, Baoan District, Shenzhen, P.R. China T F E W + 86 755 2747 1900 + 86 755 2747 2131 info@ginverter.com

More information

Super Brain 977. AC/DC Charger with Dual Output and Discharge Function. User s Manual. Model Rectifier Corporation

Super Brain 977. AC/DC Charger with Dual Output and Discharge Function. User s Manual. Model Rectifier Corporation Super Brain 977 AC/DC Charger with Dual Output and Discharge Function User s Manual Model Rectifier Corporation 80 Newfield Avenue Edison, NJ 08837-3817 Phone: 732-225-6360 www.modelrectifier.com Please

More information

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73 Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 perating Characteristics 73 Delay Curves 74 Specifications 76 Decision Tables 78 SIGLE

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES Genset Automation Control Pte Ltd DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES FEATURES Automatic mains failure, Remote start operation,

More information

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS MANUAL NUMBER: 64073 REV: 2 DATE: October 3, 2006 INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS AMERICAN BATTERY CHARGING, INC. P.O. BOX 17040 28 MAPLE AVENUE SMITHFIELD,

More information

MICRO MASTER MICRO MASTER Vector MIDI MASTER Vector

MICRO MASTER MICRO MASTER Vector MIDI MASTER Vector Standard Drives 1 W to kw VECTOR CONTROL SENSORLESS , and : The facts about the favourites Worldwide voltage ranges for a global product 1/3 phase 8-2 V AC % 3 phase 0-0 V AC % 3 phase 0-5 V AC % Greater

More information

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1 Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG102909 iss 9 1 This drive is an isolated 4 Quadrant speed controller for shunt wound or permanent magnet motors. It utilises speed feedback

More information

SPECIFICATIONS LOW COST 2404R CHARGER

SPECIFICATIONS LOW COST 2404R CHARGER SPECIFICATIONS LOW COST 2404R CHARGER Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 Volts, 2 Amp Constant Current (Equivalent to 4A tapered

More information

EVO AT SERIES BATTERY CHARGER

EVO AT SERIES BATTERY CHARGER EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger

More information

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Solid Dielectric, Three Phase Reclosers CATALOG VS11 Solid Dielectric, Three Phase Reclosers Providing electronic, three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5kA symmetrical interrupting Reliable performance

More information

Power your day-to-day when others are power-less. Humless Sentinel User s Guide.

Power your day-to-day when others are power-less. Humless Sentinel User s Guide. Power your day-to-day when others are power-less. Humless Sentinel User s Guide www. User s Guide Contents Safety Instructions page 6 Meet The Power page 7 Charging Your Unit page 12 Powering Your Devices

More information

Mini Family 300V Input

Mini Family 300V Input Actual size: 2.28 x 2.2 x 0.5in [57,9 x 55,9 x 12,7mm] Mini Family 300V Input C US C NRTL US DC-DC Converter Module S Features & Benefits DC input range: 180 375V Isolated ouput Input surge withstand:

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

BLU SERIES Battery Load Units

BLU SERIES Battery Load Units BLU SERIES Battery Load Units Lightweight starting from 12,3 kg (27 lbs) Powerful discharge power of up to 28,8 kw Voltage measurement range: up to 480 V DC Discharge current up to 340 A DC Easily expandable

More information

Chapter 9 Basic meters

Chapter 9 Basic meters Chapter 9 Basic meters Core Competency Units UEENEEE003B Solve problems in extra-low voltage single path circuits UEENEEE004B Solve problems in multiple path DC Circuits Essential Knowledge and Associated

More information

MLA Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

MLA Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA MLA05101 Bipolar Microstep Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website:

More information

POWERTRONIX QUASAR 5-40 KVA

POWERTRONIX QUASAR 5-40 KVA POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251

More information

Mini Family 72V Input

Mini Family 72V Input Actual size: 2.28 x 2.2 x 0.5in 57,9 x 55,9 x 12,7mm Mini Family 72V Input C US C NRTL US DC-DC Converter Module S Features & Benefits DC input range: 43 110V (continuous) Isolated output Encapsulated

More information

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life ITT BRSDRIVE Goulds Pumps Simplex Variable Speed Submersible Pump Controller C U L US Engineered for life Do you want to Simplify your Commercial Pumping System? Goulds Pumps S-Drive variable speed, constant

More information

Rental Power 1500 kw. Specification sheet. Description. Features. Options

Rental Power 1500 kw. Specification sheet. Description. Features. Options Specification sheet Rental Power 1500 kw Description This Cummins rental package is a fully integrated mobile power generation system, providing optimum performance, reliability, and versatility for Standby

More information

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos: PHASE CONVERTERS MODEL NO: PC40 and PC60 MODEL PART No: NO: 6012805 PC20 and PC40 6012810 PC60 PART Nos: 6012800 6012805 6012810 OPERATING & MAINTENANCE INSTRUCTIONS 0107 Specifications PC20 PC40 PC60

More information

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax: Go Power! Manual GP-1000 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS

More information

INDUSTRIAL POWER SUPPLIES SFL-SERIES

INDUSTRIAL POWER SUPPLIES SFL-SERIES INDUSTRIAL POWER SUPPLIES SFL-SERIES Operating Instructions 1. Application The SFL-series are compact, rugged switching power supplies designed for applications in process automation and other industrial

More information