MX2 INVERTER. Born to drive machines. Omron Quality with a capital Q High programming functionality Built-in safety

Size: px
Start display at page:

Download "MX2 INVERTER. Born to drive machines. Omron Quality with a capital Q High programming functionality Built-in safety"

Transcription

1 MX2 INVERTER Born to drive machines»» Omron Quality with a capital Q High programming functionality» Built-in safety

2 Harmonised motor and machine control The MX2 is specifically designed to drive machines. It has been developed to harmonise advanced motor and machine control. Thanks to its advanced design and 200% starting torque Near stand-still operation (0.5 Hz) Smooth control of high inertia loads Control of fast cyclic loads MOTOR CONTRO MCHINE CONTRO algorithms the MX2 provides smooth control down to zero speed, plus precise operation for fast cyclic operations and torque control capability in open loop. The MX2 also gives Torque control in open loop Ideal for low to medium torque applications Can replace a flux vector or servo Safety inside Conforms to safety norm ISO CT3 performance level PD 2 Safety inputs you comprehensive functionality for machine drive in suitable systems External device monitoring (EDM) control such as positioning, speed synchronisation and logic programming. The MX2 is fully integrated within the Omron smart automation platform. The MX2 is the Special motors Permanent magnet motors High speed motors up to 1000 Hz ogic programming Flow chart programming Intuitive up to 5 tasks in parallel child of a true leader in machine automation. One parameter auto-tuning Just by entering the kw rating of the motor the MX2 gives you smooth Positioning Up to 8 pre-set positions with and safe operation Homing Speed synchronisation Integrated in the Omron Smart utomation CX-Drive programming tool connected via integrated USB port on MX2. Modbus RS485 built-in Option units for EtherCT, Profibus, DeviceNet, M-II and more

3 100% Control % risk! High starting torque and torque control capability in open loop mode give you full control of your machine dynamics and performance. Options for all of the major fieldbus systems and a 24 VDC external supply keeps you in full control of your machine operation. Safety is embedded in the MX2, according to ISO , Cat 3, with two safety inputs and an External Device Monitoring (EDM) output. No external contactors on the motor side are required, meaning simpler wiring for the user. Torque 220 VC Safety redundancy input Dual safety input chain 24 VDC Torque response Torque reference Speed EDM output EDM safety output chain Torque master The MX2 delivers 200% starting torque near stand-still (0.5 Hz) and can operate in torque control in open loop mode. This allows the MX2 to be used in applications where closed loop C vector drives were previously used. Easy network integration Built-in RS485 Modbus communications and the possibility for integration in standard industrial networks, such as Dnet, Profibus, CNopen, CompoNet, M-II or EtherCat makes the MX2 exceptionally easy to integrate. External 24 VDC for continuous operation With no additional hardware, a 24 VDC connection to the MX2 ensures the CPU is always in control, even if the main input is removed. This feature is vital in providing a controlled stop in emergency situations and in keeping the network communications operating. Safety embedded; ISO , cat 3 Dual contactors at the output of the inverter are no longer required. Direct connection to a safety controller ensures compliance to ISO , cat 3. EDM monitoring output n External Device Monitoring (EDM) output confirms the safety status of the inverter, saving you the cost and wiring of external devices to carry out the same function. Direct integration into the safety circuit MX2 inverters can fit easily into the safety circuit. The safety inputs can be linked from one inverter to another without additional safety relays.

4 Position and run! Program and play! The MX2 is a drive and position controller in one, ideal for modular machines where moderate positional accuracy is required. Speed synchronisation is also possible, with no additional programming required. The MX2 gives you the power to create smart solutions using PC functionality, as standard. Via an intuitive flow chart programming tool, you can create programs with up to 1000 lines of code and with 5 tasks running in parallel. Speed synchronisation Positioning functionality Free to program With no external hardware required, and via standard parameter settings, speed synchronisation can be achieved. The MX2 will act as a speed follower to an external pulse generator/ encoder signal up to 32 KHz. Specially developed application functionality enables the MX2 to solve simple positioning tasks without the need for an external controller. Up to 8 positions, plus home, can be selected by the user, and furthermore, the MX2 can be switched between speed and position mode. Intuitive and user friendly flow chart programming Integrated in CX-Drive Up to 1000 lines in a program 5 tasks can run in parallel Speed X00 X01

5 MX2 Born to drive machines Current vector control High starting torque: 200% at 0.5Hz Double rating VT 120%/1min and CT 150%/1min Speed range up to 1000 Hz IM & PM motor control Torque control in open loop vector Positioning functionality Built-in application functionality (i.e. Brake control) User programmable as standard Safety embedded compliant with ISO (double input circuit and external device monitor EDM) USB port for PC programming 24 VDC backup supply for control board Fieldbus communications: Modbus, DeviceNet, Profibus, Componet, Ethercat, M-II and CanOpen PC configuration tool: CX-Drive RoHS, CE, cuus Ratings 200 V Class single-phase 0.2 to 2.2 kw 200 V Class three-phase 0.2 to 15.0 kw 400 V Class three-phase 0.4 to 15.0 kw System configuration Power Supply MCCB USB Cable CX-Drive CX-One Input C Reactor Remote Operator Extansion Cable CD 5 lines Remote Operator Filter Communication Option Board MX2 Braking Resistor Choke DC Reactor Motor Output C Reactor Ground 8 Frequency inverters

6 Specifications Type designation MX2B002-E MX2 series : Standard specs Voltage: B: Single-phase 200 VC 2: Three-phase 200 VC 4: Three-phase 400 VC E: Europe standard Max. applicable motor output 002: 0,2 kw ~ 150: 15,0 kw 200 V class Motor kw 2 Output characteristics Power supply Single-phase: MX2@ B001 B002 B004 B Three phase model use forced-air-cooling but single phase model is self cooling. 2. Based on a standard 3-Phase standard motor. 3. bove 400Hz with some function limitation. B015 B Three-phase: MX2@ For VT setting For CT setting VT Inverter capacity kv 200 CT VT CT Rated output current () at VT Rated output current () at CT Max. output voltage Proportional to input voltage: V Max. output frequency 1000 Hz 3 Rated input voltage and frequency Single-phase V 50/60 Hz 3-phase V 50/60 Hz llowable voltage fluctuation -15%..+10% llowable frequency fluctuation 5% Braking torque t short-time deceleration t capacitor feedback 100%: <50Hz 50%: <60Hz 70%: <50Hz 50%: <60Hz pprox 20% - Cooling method Self cooling Forced-air-cooling 400 V class Motor kw 1 Output characteristics Power supply Three-phase: MX2@ For VT setting For CT setting VT Inverter capacity kv 380 CT VT CT Rated output current () at VT Rated output current () at CT Max. output voltage Proportional to input voltage: V Max. output frequency 1000 Hz 2 Rated input voltage and frequency 3-phase V 50/60 Hz llowable voltage fluctuation -15%..+10% llowable frequency fluctuation 5% Braking torque t short-time deceleration *3 t capacitor feedback 1. Based on a standard 3-Phase standard motor. 2. bove 400Hz with some function limitation. 100%: <50Hz 50%: <60Hz 70%: <50Hz 50%: <60Hz Cooling method Self cooling Forced-air-cooling - MX2 9

7 Specifications Commom specifications Control functions Functionality Protection functions mbient conditions Model number Specifications Control methods Phase-to-phase sinusoidal pulse with modulation PWM (Sensorless vector control, V/F) Output frequency range Hz (with restrictions above 400Hz) Digital set value: ±0.01% of the max. frequency Frequency precision nalogue set value: ±0.2% of the max. frequency (25 ±10 ºC) Digital set value: 0.01 Hz Resolution of frequency set value nalogue set value: 1/1000 of maximum frequency Resolution of output frequency 0.01Hz Starting torque 200% / 0.5Hz Dual rating: Overload capability Heavy duty (CT): 150% for 1 minute Normal Duty (VT): 120% for 1 minute Frequency set value 0 to 10 VDC (10KΩ), 4 to 20m (100Ω), RS485 Modbus, Network options V/f Characteristics Constant/ reduced torque, free V/f FW (forward run command), RV (reverse run command), CF1~CF4 (multi-stage speed setting), JG (jog command), DB (external braking), SET (set second motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), T (analog input selection), RS (reset), PTC (thermistor thermal protection), ST (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (remote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control), SF1~SF7 (multi-stage speed setting; bit operation), OR (overload restriction), T (torque limit enable), TRQ1 (torque limit Inputs signals changeover1), TRQ2 (torque limit changeover2), BOK (Braking confirmation), C (D cancellation), PCR (position deviation clear), DD (add frequency enable), F-TM (force terminal mode), TR (permission of torque command input), KHC (Cumulative power clear), MI1~MI7 (general purpose inputs for EzSQ), HD (analog command hold), CP1~CP3 (multistageposition switches), OR (limit signal of zero-return), ORC (trigger signal of zero-return), SPD (speed/position changeover), GS1~GS2 (STO inputs, safety related signals), 485 (Starting communication signal), PRG (executing EzSQ program), HD (retain output frequency), ROK (permission of run command), EB (rotation direction detection of B-phase), DISP (display limitation), OP (option control signal), NO (no function) RUN (run signal), F1~F5 (frequency arrival signal), O,O2 (overload advance notice signal), OD (PID deviation error signal), (alarm signal), OTQ (over/under torque threshold), UV (under-voltage), TRQ (torque limit signal), RNT (run time expired), ONT (power ON time expired), THM (thermal warning), BRK (brake release), BER (brake error), ZS (0Hz detection), DSE (speed deviation excessive), POK (positioning completion), ODc (analog voltage input disconnection), OIDc (analog current input disconnection), FBV (PID second stage output), NDc (network disconnect detection), OG1~OG3 (ogic output signals), WC (capacitor life warning), WF (cooling fan warning), FR (starting contact), OHF (heat sink overheat warn- Output signals ing), OC (ow load), MO1~MO3 (general outputs for EzSQ), IRDY (inverter ready), FWR (forward operation), RVR (reverse operation), MJ (major failure), WCO (window comparator O), WCOI (window comparator OI), FREF (frequency command source), REF (run command source), SETM (second motor in operation), EDM (STO (safe torque off) performance monitor), OP (option control signal), NO (no function) Free-V/f, manual/automatic torque boost, output voltage gain adjustment, VR function, reduced voltage start, motor data selection, auto-tuning, motor stabilization control, reverse running protection, simple position control, simple torque control, torque limiting, automatic carrier frequency reduction, energy saving operation, PID function, non-stop operation at instantaneous power failure, brake control, DC injection braking, dynamic braking (BRD), frequency upper and lower limiters, jump frequencies, curve accel and decel (S, U, inversed U,E-S), 16-stage speed profile, fine adjustment of start Standard functions frequency, accel and decel stop, process jogging, frequency calculation, frequency addition, 2-stage accel/decel, stop mode selection, start/end freq., analog input filter, window comparators, input terminal response time, output signal delay/hold function, rotation direction restriction, stop key selection, software lock, safe stop function, scaling function, display restriction, password function, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry, frequency pull-in restart, frequency matching, overload restriction, over current restriction, DC bus voltage VR nalogue inputs 2 analogue inputs 0 to 10V (10KΩ), 4 to 20m (100Ω) Pulse train input terminal 0 to 10V (up to 24V), up to 32KHz ccel/decel times 0.01 to s (line/curve selection), 2nd accel/decel setting available Status indicator ED s Run, Program, larm, Power, Hz, mps Display Digital operator: vailable to monitor 32 items: frequency reference, output current, output frequency... Motor overload protection Electronic Thermal overload relay and PTC thermistor input Instantaneous overcurrent 200% of rated current Dual rating: Overload Heavy duty (CT): 150% for 1 minute Normal Duty (VT): 120% for 1 minute Overvoltage 800V for 400V type and 400V for 200V type Undervoltage 345V for 400V type and 172.5V for 200V type Momentary power loss Following items are selectable: larm, decelerates to stop, decelerates to stop with DC bus controlled, restart Cooling fin overheat Temperature monitor and error detection Stall prevention level Stall prevention during acceleration/deceleration and constant speed Ground fault Detection at power-on Power charge indication On when power is supplied to the control part Degree of protection IP20, Varnish coating on PCB mbient humidity 90% RH or less (without condensation) Storage temperature -20 ºC..+65 ºC (short-term temperature during transportation) mbient temperature 10 C to 40 C Installation Indoor (no corrosive gas, dust, etc.) Installation height Max m Vibration 5.9 m/s 2 (0.6G), 10 to 55 Hz 10 Frequency inverters

8 R f R l w Q?@ h m u d q s d q r s n o q d r d s q t m g š o v q ` k l ` o q f R f R l w Q q t m r x r c q h u d?@ h m u d q s d q r s n o q d r d s q t m g š o v q ` k l ` o q f R f R l w Q?@ h m u d q s d q q t m q t m o v q g š ` k l ` o q f r s n o q d r d s Dimensions W1 W φ 4.5 W W1 φ 2-d W W1 φ 2-d q t m H1 H H1 H H1 H 5 t t D Figure 1 D Figure 2 D1 D Figure 3 2,6 D1 D2 D1 D2 Dimensions in mm Voltage class Inverter model MX2@ Figure W W1 H H1 t D D1 D2 d Weight (KG) B B Single-phase 200 V Three-phase 200 V Three-phase 400 V B B B B Rasmi footprint Filters 1x200 V 3x200 V 3x400 V Rasmi model Dimensions W H X Y M X-FIM1010-RE M4 X-FIM1014-RE M4 X-FIM1024-RE M4 X-FIM2010-RE M4 X-FIM2020-RE M4 X-FIM2030-RE M4 X-FIM2060-RE M5 X-FIM2080-RE M5 X-FIM2100-RE M6 X-FIM3005-RE M4 X-FIM3010-RE M4 X-FIM3014-RE M4 X-FIM3030-RE M5 X-FIM3050-RE M5 MX2 11

9 Option board 30.7 Input C Reactor Voltage 200V 400V DC Reactor Output C Reactor Dimensions B2 C2 D E F Weight Kg X-RI DE X-RI DE X-RI DE X-RI DE X-RI DE X-RI DE X-RI DE X-RI DE Voltage Dimensions Weight B C D E F G H Kg X-RC DE X-RC DE X-RC DE X-RC DE 1.60 X-RC DE V X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE V X-RC DE X-RC DE X-RC DE X-RC DE Voltage 200V Dimensions Weight B2 C2 D E F Kg X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE Frequency inverters

10 Voltage 400V Dimensions Weight B2 C2 D E F Kg X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE Chokes D diameter Motor KW Dimensions Weight Kg W H X Y m X-FER2102-RE 21 < X-FER2515-RE 25 < X-FER5045-RE 50 < W Y X Ø m H Ø d Resistor Dimensions X-REM00K1200 Fig 1 Fig 2 Fig 3 Fig 4 Type Fig. Dimensions Weight H M I T KG X-REM00K1400-IE X-REM00K2070-IE X-REM00K2120-IE X-REM00K2200-IE X-REM00K4075-IE 1 X-REM00K4035-IE X-REM00K4030-IE X-REM00K5120-IE X-REM00K6100-IE X-REM00K6035-IE X-REM00K9070-IE X-REM00K9020-IE X-REM00K9017-IE X-REM01K9070-IE X-REM01K9017-IE X-REM02K1070-IE X-REM02K1017-IE 4 X-REM03K5035-IE X-REM03K5010-IE MX2 13

11 Standard connections Breaker, MCCB or GFI Power source, 3-phase or 1-phase, per inverter model Thermistor Meter Meter Intelligent inputs, 7 terminals NOTE: For the wiring of intelligent I/O and analog inputs, be sure to use twisted pair/ shielded cable. ttach the shielded wire for each signal to its respective common terminal at the inverter end only. Input impedance of each intelligent input is 4.7kΩ Forward Short bar (Source type) GND for logic inputs nalog reference 0~10VDC 4~20m Pulse train input 24Vdc 32kHz max. GND for analog signals R (1) S (2) T N(3) 24V P /GS1 4/GS2 5/PTC 6 7/EB PC EO M H O OI E Input circuits MX2 [5] configurable as discrete input or thermistor input pprx.10kω pprx.100ω + - Output circuit Termination resistor (200Ω) (Change by slide switch) 10Vdc RS485 transceiver RS485 transceiver USB transceiver Option port controller U(T1) V(T2) W(T3) PD/+1 P/+ RB N/ /EDM Open collector output Freq. arrival signal oad 12 oad CM2 SP SN Brake resistor (optional) Relay contacts, type 1 Form C + - GND for logic outputs Serial communication port (RS485/ModBus) RJ45 port (Optional operator port) USB (mini-b) port (PC communication port) USB power: Self power Option port connector Motor DC reactor (optional) Braking unit (optional) Terminal Block Specifications Terminal Name Function (signal level) R/1, S/2, T/3 Main circuit power supply input Used to connect line power to the drive. Drives with single-phase 200 V input power use only terminals R/1 and N (T/3), terminal S/2 is not available for these units U/T1, V/T2, W/T3 Inverter output Used to connect the motor PD/+1, P/+ External DC reactor terminal Normally connected by the short-circuit bar. Remove the short-circuit bar between +1 and P/ +2 when a DC reactor is connected. P/+, N/- Regenerative braking unit terminal Connect optional regenerative braking units (If a braking torque is required) P/+, RB Braking resistor terminals Connect option braking resistor (if a braking torque is required) Grounding For grounding (grounding should conform to the local grounding code.) 14 Frequency inverters

12 Control Circuit Type No. Signal name Function Signal level PC Intelligent input common Source type: connecting [P24] to [1]-[7] turns inputs ON Sink type: connecting [] to [1]-[7] turns inputs ON - P24 Internal 24 VDC 24 VDC, 30m 24VDC, 30m Digital input signals 1 Multi-function Input selection 1 Factory setting: Forward/ Stop 2 Multi-function Input selection 2 Factory setting: Reverse/ Stop 3/ST1 Multi-function Input selection 3 / safe stop input 1 Factory setting: External trip 4/ST2 Multi-function Input selection 4 / safe stop input 2 Factory setting: Reset 5/PTC Multi-function Input selection 5 / PTC thermistor input Factory setting: Multi-step speed reference 1 6 Multi-function input selection 6 Factory setting: Multi-step speed reference 2 27 VDC max 7/EB Multi-function input selection 7 / Pulse train input B Factory setting: Jog Pulse train nalog input signal Digital output signals Multi-function Input selection common (in upper row) E Pulse train input Factory setting: Speed reference EO Pulse train output D frequency H Frequency reference power supply 10 V DC 10m max O Voltage frequency reference signal 0 to 10V DC (10KΩ) OI Current frequency reference signal 4 to 20m (250Ω) Frequency reference common (bottom row) -- 11/EDM Discrete logic output 1 / EDM output Factory setting: During Run 12 Discrete logic output 2 Factory setting: Frequency arrival type 1 CMD GND logic output Relay commom contact Relay contact, normally open Relay contact, normally closed Factory setting: larm signal Under normal operation 1-0 Closed 2-0 Open 32KHz max 5 to 24VDC 10VDC 2m 32KHz max 27 VDC, 50m max EDM based on ISO R load 250VC VDC 3.0 I load 250VC VDC 0.7 Monitor Signal M nalog voltage output Factory setting: D frequency 0 to 10VDC 1m Comms Side by side mounting SP Serial communication terminal SN RS485 Modbus communication Enclosure Inverter heat loss Three-phase 200 V class Model MX VT Inverter 200 CT capacity kv 240 VT CT Rated current () VT Rated current () CT Total heat loss Efficiency at rated load Cooling Method Self cooling Forced-air-cooling MX2 15

13 Single-phase 200 V class Inverter capacity kv Model MX2 B001 B002 B004 B007 B015 B V VT V CT V VT V CT Rated current () VT Rated current () CT Total heat loss Efficiency at rated load Cooling Method Self cooling Forced-air-cooling Three-phase 400 V class Inverter capacity kv Model MX V VT V CT V VT V CT Rated current () VT Rated current () CT Total heat loss Efficiency at rated load Cooling Method Self cooling Forced-air-cooling Input C Reactor C reactor MX2 Power supply MCCB U X R/1 V Y S/2 W Z T/3 3 phase 200 V class 400 V class Current value Inductance Max. applicable Current value mh motor output kw 1.5 X-RI DE X-RI DE X-RI DE X-RI DE X-RI DE X-RI DE X-RI DE X-RI DE Max. applicable motor output kw Inductance mh DC Reactor Power supply MCCB R/1 MX2 S/2 T/3 +1 P/ V class 400 V class Current value Inductance mh Max. applicable motor output kw Current value 0.2 X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE X-RC DE Max. applicable motor output kw Output C Reactor DC reactor Inductance mh 200 V class 400 V class Max. applicable Current value Inductance Max. applicable Current value Inductance motor output kw mh motor output kw mh 0.4 X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE Frequency inverters

14 Ordering information Power Supply MCCB B USB Cable E CX-Drive CX-One Input C Reactor Filter B Remote Operator Extansion Cable C Communication option B CD 5 lines Remote Operator MX2 D Braking Resistor Choke Motor DC Reactor Output C Reactor Ground MX2 Voltage class Single-phase 200 V Three-phase 200 V Three-phase 400 V Specifications Model Constant torque Variable torque Max motor kw Rated current Max motor kw Rated current Standard MX2-B001-E MX2-B002-E MX2-B004-E MX2-B007-E MX2-B015-E MX2-B022-E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX E MX2 17

15 ine filters Inverter Voltage Model 1-Phase 200 VC 3-Phase 200 VC 3-Phase 400 VC ine filter Rasmi Rated current () B001 / B002 / B004 X-FIM1010-RE 10 B007 X-FIM1014-RE 14 B015 / B022 X-FIM1024-RE / 2002 / 2004 / 2007 X-FIM2010-RE / 2022 X-FIM2020-RE X-FIM2030-RE / 2075 X-FIM2060-RE X-FIM2080-RE X-FIM2100-RE / 4007 X-FIM3005-RE / 4022 / 4030 X-FIM3010-RE X-FIM3014-RE / 4075 X-FIM3030-RE / 4150 X-FIM3050-RE 50 Input C Reactors Inverter C Reactor Voltage Model MX2-@ 2002 / 2004 / 2007 X-RI DE 3-Phase 200 VC 1-Phase 200 VC 3-Phase 400 VC 2015 / 2022 / 2037 X-RI DE 2055 / 2075 X-RI DE 2110 / 2150 X-RI DE B002 / B004 B007 Under development B015 / B / 4007 / 4015 X-RI DE 4022 / 4030 / 4040 X-RI DE 4055 / 4075 X-RI DE 4110 / 4150 X-RI DE DC Reactors 200V single phase 200V 3-phase 400V 3-phase Inverter DC Reactor Inverter DC Reactor Inverter DC Reactor MX2-B001 MX MX X-RC DE X-RC DE X-RC DE MX2-B002 MX MX X-RC DE MX2-B004 X-RC DE MX X-RC DE MX X-RC DE MX2-B007 X-RC DE MX X-RC DE MX X-RC DE MX2-B015 X-RC DE MX X-RC DE MX X-RC DE MX2-B022 X-RC DE MX X-RC DE MX X-RC DE MX X-RC DE MX X-RC DE MX X-RC DE MX X-RC DE - MX X-RC DE MX X-RC DE MX X-RC DE MX X-RC DE MX X-RC DE - Chokes Model Diameter Description X-FER2102-RE 21 For 2.2 KW motors or below X-FER2515-RE 25 For 15 KW motors or below X-FER5045-RE 50 For 45 KW motors or below Output C Reactor Inverter C Reactor Voltage Model MX2-@ 200 VC 400 VC 2001 / 2002 / 2004 B001 / B002 / B /B / B / B / 4007 / / X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE X-RO DE B ccessories Types Model Description Functions 3G3X-OP05 CD remote operator 5 ine CD remote operator with copy function, cable length max. 3m. Digital operator 3G3X-CJOP300-EE Remote operator cable 3 meters cable for connecting remote operator ccessories X-CUSBM002-E PC configuration cable Mini USB to USB connector cable 18 Frequency inverters

16 C Communication option boards Types Model Description Functions Used for running or stopping the inverter, setting or referencing parameters, and monitoring 3G3X-MX2-PRT Profibus option card output frequency, output current, or similar items through Profibus communications with the host controller. Communication options 3G3X-MX2-DRT 3G3X-MX2-ERT 3G3X-MX2-CRT 3G3X-MX2-M2 DeviceNet option card Ethercat option card CompoNet option card Mechatrolink II option card Under development 3G3X-MX2-CORT CanOpen option card D Braking unit, braking resistor unit Voltage 200 V (single-/ threephase) 400 V (threephase) Max. motor kw Inverter Braking resistor unit Inverter MX2@ Connectable Inverter mounted type Inverter mounted type min. (3 %ED, 10 sec max) Braking (10%ED, 10 sec max) torque % 3-phase 1-phase resistance Ω Type X- Resist Ω Type X- Resist Ω Braking torque % B REM00K1400-IE 400 REM00K1400-IE B B REM00K1200-IE REM00K1200-IE B REM00K2070-IE B REM00K4075-IE REM00K2070-IE B REM00K4035-IE REM00K4075-IE REM00K6035-IE REM00K9020-IE REM00K4035-IE REM01K9017-IE REM00K6035-IE REM02K1017-IE REM00K9017-IE REM03K5010-IE REM00K1400-IE 400 REM00K1400-IE REM00K1200-IE REM00K2200-IE REM00K2200-IE REM00K5120-IE REM00K2120-IE REM00K6100-IE REM00K9070-IE REM00K4075-IE REM01K9070-IE REM00K6100-IE REM02K1070-IE REM00K9070-IE REM03K5035-IE E Computer software Types Model Description Installation Software CX-drive Computer software Configuration and monitoring software tool CX-One Computer software Configuration and monitoring software tool DIMENSIONS SHOWN RE IN MIIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by Cat. No. I113E-EN-01 In the interest of product improvement, specifications are subject to change without notice. MX2 19

17 OMRON EUROPE B.V. Wegalaan 67-69, N-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) Fax: +31 (0) ustria Tel: +43 (0) Germany Tel: +49 (0) Portugal Tel: Turkey Tel: Belgium Tel: +32 (0) Hungary Tel: Russia Tel: United Kingdom Tel: +44 (0) Czech Republic Tel: Italy Tel: South-frica Tel: +27 (0) Denmark Tel: Netherlands Tel: +31 (0) Spain Tel: Finland Tel: +358 (0) Norway Tel: +47 (0) Sweden Tel: +46 (0) France Tel: +33 (0) Poland Tel: +48 (0) Switzerland Tel: +41 (0) More Omron representatives utomation Systems Programmable logic controllers (PC) Human machine interfaces (HMI) Remote I/O Industrial PC s Software Motion & Drives Motion controllers Servo systems Inverters Control Components Temperature controllers Power supplies Timers Counters Programmable relays Digital panel indicators Electromechanical relays Monitoring products Solid-state relays imit switches Pushbutton switches ow voltage switch gear Sensing & Safety Photoelectric sensors Inductive sensors Capacitive & pressure sensors Cable connectors Displacement & width-measuring sensors Vision systems Safety networks Safety sensors Safety units/relay units Safety door/guard lock switches KPP_MX2_EN_INT01 lthough we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant or make any representations regarding the correctness or completeness of the information described in this document. We reserve the right to make any changes at any time without prior notice.

MX2 inverter. »»Built-in safety. Born to drive machines. »» Omron Quality with a capital Q»»High programming functionality

MX2 inverter. »»Built-in safety. Born to drive machines. »» Omron Quality with a capital Q»»High programming functionality MX2 inverter Born to drive machines»» Omron Quality with a capital Q»»High programming functionality»»built-in safety Harmonised motor and machine control The MX2 is specifically designed to drive machines.

More information

MX2. Честотни инвертори за регулиране оборотите на трифазни асинхронни двигатели векторно управление. System configuration

MX2. Честотни инвертори за регулиране оборотите на трифазни асинхронни двигатели векторно управление. System configuration MX2 Честотни инвертори за регулиране оборотите на трифазни асинхронни двигатели векторно управление Born to drive machines Current vector control High starting torque: 200% at 0.5 Hz Double rating VT 120%/1

More information

WINDER solutions. Inverter Application Software

WINDER solutions. Inverter Application Software WINDER solutions Application Software Application Software... Based on OMRON s experience in winder applications, the RX inverter offers four times faster torque control loop. In addition to this torque

More information

S8V POWER SUPPLIES. High capacity in a compact format. » Long life switch mode power supplies. » performance and reliability

S8V POWER SUPPLIES. High capacity in a compact format. » Long life switch mode power supplies. » performance and reliability S8V POWER SUPPLIES High capacity in a compact format» performance and reliability» Long life switch mode power supplies» Complete single and 3 - phase ranges All the power to suit your needs... Our S8V

More information

SX SERIES. Force & flow in harmony.»» IP54 compact size»»690 V power supply»»true application oriented inverter

SX SERIES. Force & flow in harmony.»» IP54 compact size»»690 V power supply»»true application oriented inverter SX SERIES Force & flow in harmony»» IP54 compact size»»690 V power supply»»true application oriented inverter Safe force and smooth flow Designed to drive any high power application from 90 kw up to 1

More information

MX2. System configuration

MX2. System configuration Y203EN205+MotionDrives+Cat.book Seite 223 Freitag, 10. Juni 2011 4:05 16 MX2 Born to drive machines Current vector control High starting torque: % at 0.5 Hz Double rating VT 120%/1 min and CT 150%/1 min

More information

MX2 IP54 INVERTER. Flexibility and robust design for standalone solutions

MX2 IP54 INVERTER. Flexibility and robust design for standalone solutions MX2 IP54 INVERTER Flexibility and robust design for standalone solutions»» Robust metal housing»» Freedom for user customization»» Built-in logic programming MX2 IP54 Robust and flexible inverter... The

More information

MX2. System configuration

MX2. System configuration MX2 Born to drive machines Current vector control High starting torque: 200% at 0.5 Hz Double rating VT 120%/1 min and CT 150%/1 min IM & PM motor control Torque control in open loop vector Positioning

More information

3G3MX2 AC Drives. Born to drive machines. »» Built-in safety. »» Omron Quality with a capital "Q"»» High programming functionality

3G3MX2 AC Drives. Born to drive machines. »» Built-in safety. »» Omron Quality with a capital Q»» High programming functionality 3G3MX2 AC Drives Born to drive machines»» Omron Quality with a capital "Q"»» High programming functionality»» Built-in safety Harmonized motor and machine control MOTOR CONTROL The 3G3MX2 is specifically

More information

L300P Inverter Specifications

L300P Inverter Specifications L300P Inverter Specifications Tables for 200V class inverters Note that General Specifications on page 1 9 covers all L300P inverters, followed by footnotes for all specifications tables. Seven 200V models

More information

SJ300 Inverter Specifications

SJ300 Inverter Specifications SJ300 Inverter Specifications Tables for 200V class inverters Note that General Specifications on page 1 9 covers all SJ300 inverters, followed by footnotes for all specifications tables. The 200V models

More information

USB Copy Unit COM ERR. Copy. RJ-45 / USB Adapter. Verify. Read LOCK YASKAWA JVOP-181. Remote Operator Extansion Cable. Communication Option Board

USB Copy Unit COM ERR. Copy. RJ-45 / USB Adapter. Verify. Read LOCK YASKAWA JVOP-181. Remote Operator Extansion Cable. Communication Option Board YSKW VZ V1000 More performance & Quality in less space Current vector control High starting torque (200% / 0.5 Hz) 1:100 speed control range Double rating ND 120%/1min and HD 150%/1 min IM&PM motor control

More information

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL Dual Rating NRTL/C CERTIFIED Technologies Inc. mgitech.com Sensor/Sensorless Vector Control Dual current rated for constant and variable torque Auto

More information

3G3JX AC DRIVES. Compact and complete. »» Cost a n d e co-friendly. Downloaded from Elcodis.com electronic components distributor

3G3JX AC DRIVES. Compact and complete. »» Cost a n d e co-friendly. Downloaded from Elcodis.com electronic components distributor AC DRIVES Compact and complete»» Q u a l i t y & re l i a b i l i t y y o u c a n d e p e n d o n»» Co m m u n i c a t i o n s b u i l t- i n»» Cost a n d e co-friendly The smallest gets integrated...

More information

SCARA robots for industrial applications

SCARA robots for industrial applications Industrial robots SCARA robots for industrial applications»» Reliable and versatile»»simple programming and quick set-up»»pick & Place A win-win mechatronics proposition Your benefits: Simplify your machines

More information

RS232 Communications cable with PC ER M. RJ-45 / USB Adapter Remote Operator Extansion Cable. Communication Unit. Mounting Accesories

RS232 Communications cable with PC ER M. RJ-45 / USB Adapter Remote Operator Extansion Cable. Communication Unit. Mounting Accesories JZ J1000 The basic inverter V/f controlled inverter Good torque performance (150% / 3 Hz) Double rating ND 120%/1min and HD 150%/1 min Overload detection function (150% during 60s) Motor thermal function

More information

Ratings 200 V class three-phase: 0.4 kw to 55 kw 400 V class three-phase: 0.4 kw to 132 kw System configuration. RJ45 - USB cable. Digital.

Ratings 200 V class three-phase: 0.4 kw to 55 kw 400 V class three-phase: 0.4 kw to 132 kw System configuration. RJ45 - USB cable. Digital. RX Customised to your machine High starting torque in open loop: 200% at 0.3 Hz, Full torque at 0 Hz in closed loop Sensor-less and vector closed-loop control Double rating VT 120%/1 min and CT 150%/1

More information

Pick & Place solutions

Pick & Place solutions Pick & Place solutions» Delta solution integrated into the Sysmac platform» Washdown and hygienic Delta robot» SCARA series expanded with new belt-less models Delta and SCARA solutions With more than 50

More information

SYSDrive Frequency Inverter

SYSDrive Frequency Inverter SYSDrive Frequency Inverter T V/f control T PID control T Standard LED, optional LCD operator T Fieldbus options: DeviceNet T 7 configurable digital inputs T 3 configurable digital outputs T Low audible

More information

Frequency Inverters SJ Series Type P1

Frequency Inverters SJ Series Type P1 Frequency Inverters SJ Series Type P1 Automation Solutions by Hitachi SJ Series, Type P1 High Performance Inverter Hitachi maintains research and development departments throughout the business. These

More information

Varispeed J7 CIMR-J7AZ. System configuration

Varispeed J7 CIMR-J7AZ. System configuration CIMR-J7AZ Varispeed J7 Small, simple and smart V/f controlled inverter Compact size Good torque performance: 100% torque at 1.5 Hz, 150% at 3 Hz 150% overload / 60sec Overload detection function. Motor

More information

RX INVERTER. Customised to your machine.» High motor-control performance

RX INVERTER. Customised to your machine.» High motor-control performance RX INVERTER Customised to your machine» High motor-control performance» B u i l t- i n k n o w - h o w f u n c t i o n a l i ty» U n c o m p ro m i s i n g O m ro n q u a l i ty High performance to match

More information

RX Inverter. Customised to your machine.» High motor-control performance» Built-in know-how functionality» Uncompromising Omron quality

RX Inverter. Customised to your machine.» High motor-control performance» Built-in know-how functionality» Uncompromising Omron quality RX Inverter Customised to your machine» High motor-control performance» Built-in know-how functionality» Uncompromising Omron quality High performance to match your application Key features include: Omron

More information

GS2 Series - Introduction

GS2 Series - Introduction GS2 Series - Introduction GS2 Series Drives Rating Hp.25.5 1 2 3 5 7.5 10 kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Single-Phase 115 Volt Class Single/Three-Phase 230 Volt Class Three-Phase 230 Volt Class Three-Phase

More information

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES INVERTER SERIES Varispeed E VARISPEED E YASKAWA INVERTER DRIVE TECHNOLOGY Contents Content Page 2 Experience & Innovation A leader in Drives technology Page 3 Specifications Experience & Innovation For

More information

J1000 D E F I 1000 J1000 J1000 J1000 J1000

J1000 D E F I 1000 J1000 J1000 J1000 J1000 Compact Inverter SERIES J1000 GB D E F I 1000 J1000 J1000 J1000 J1000 The J-Type YASKAWA Inverter Drive Technology Contents Page 2 Experience & Innovation A leader in Inverter Drives technology Page 3

More information

Delta Products VFD CP2000 Bypass Control Packages.

Delta Products VFD CP2000 Bypass Control Packages. Delta Products VFD CP2000 Bypass Control Packages www.deltaww.com Delta Products VFD CP2000 Bypass Control Packages The Delta Products VFD CP2000 Bypass Control Packages are designed for the Delta Products

More information

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA Honeywell CORE Drive SPECIFICATION DATA FEATURES APPLICATION The new Honeywell VFD CORE Drive addresses the need to save time for installation, and provides the lower total installed costs with years of

More information

V1000. Inverter Series.

V1000. Inverter Series. V1000 Inverter Series www.yaskawa.eu.com One for all The V1000 is a general purpose inverter drive covering the demands of a wide field of applications. Simple duties as well as requirements of complex

More information

V1000 Inverter Series

V1000 Inverter Series V1000 Inverter Series www.yaskawa.eu.com One for all The V1000 is a general purpose inverter drive covering the demands of a wide field of applications. Simple duties as well as requirements of complex

More information

J1000. Compact Inverter Series.

J1000. Compact Inverter Series. J1000 Compact Inverter Series www.yaskawa.eu.com Focus on Application Customer orientation and application focus two attributes of machine equipment YASKAWA offers with its J1000 compact inverter drive

More information

CIMR-V7AZ Varispeed V7

CIMR-V7AZ Varispeed V7 CIMR-V7AZ Sensorless vector in pocket size 150% overload / 60 sec 100% torque at 0.5 Hz Autotuning High carrier up to 14 khz Stop accuracy 2 motors controller Integrated PID controller and bidireccional

More information

High performance Vector Control. Ratings. System configuration

High performance Vector Control. Ratings. System configuration System configuration High performance Vector Control Low harmonic or regenerative drive IP54 full range Compact design and robustness Built-in filter (according to C3 class) Built-in fuses (from 200 kw)

More information

Technical Information

Technical Information Yaskawa Electric Europe GmbH Hauptstraße 185 65760 Eschborn Germany Tel. +49 (0)61 96/569 300 Technical Information Topic Replacement Varispeed C+ with Reference: UEW0101D Source: Based on YEC document

More information

VFD E Series. Features

VFD E Series. Features VFD E Series Output Frequency : 0.1 ~ 600 Hz. Built in PLC Function 500 Step program in Ladder Language. Side by side installation. Easy maintenance. Modular & Compact Design. Built-in MODBUS communication.

More information

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V LIFT INVERTER SERIES EN DE ES FR IT 1000V YASKAWA INVERTER DRIVE TECHNOLOGY Contents Page 2 Introduction Experience & Innovation YASKAWA speaks Lift Page 3 YASKAWA Main Features Page 4 Specifications Page

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M600 features Easy click-in keypad

More information

Quick Start Guide of CV50- ControlVIT Series

Quick Start Guide of CV50- ControlVIT Series ❶ Safety precautions Do not refit the inverter unauthorizedly; otherwise fire, electric shock or other injury may occur. Please install the inverter on fire-retardant material and keep the inverter away

More information

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs 0.25 kw - 110 kw (0.33 hp - 150 hp) 100 V 200 V 400 V 575 V 690 V Unidrive M400 features Optional AI-485

More information

V1000 DE ES FR IT V1000 V1000 V1000 V1000

V1000 DE ES FR IT V1000 V1000 V1000 V1000 Inverter Series V1000 EN DE ES FR IT 1000 V1000 V1000 V1000 V1000 V1000 YASKAWA Inverter Drive Technology Contents Page 2 Experience & Innovation A leader in Inverter Drives technology V1000 Easy and cost-saving

More information

Experience & Innovation

Experience & Innovation Yaskawa L1000A For High-Performance Elevator Application CONTENTS Experience & Innovation...2 Advanced Motor / Drive Technology...3-5 Simple Programming...5 Main Features...6-7 Maintainability & Certifications...8

More information

MX1S Matrix Converter

MX1S Matrix Converter MX1S Matrix Converter Energy-Saving Medium-Voltage Drive with Power Regeneration 4.16 kv, 500 to 4000 HP, UL Listed Also available in 3 kv and 6kV Class Certified for ISO9001 and ISO14001 CERTI F I ED

More information

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006 Quick Reference Guide For NFX9000 Adjustable Frequency Drives February 2006 5011640900 NQ00 MN04001003E February 2006 Hazardous High Voltage WARNING Motor control equipment and electronic controllers are

More information

A1000 D E A1000 A1000 A1000 A1000

A1000 D E A1000 A1000 A1000 A1000 Inverter Series High Performance Vector Control GB D E F I 1000 Yaskawa High Performance Drive Contents Page 2 Experience & Innovation A leader in Inverter Drives technology Main Features Page 3 Customize

More information

LIFT INVERTER SERIES L1000A

LIFT INVERTER SERIES L1000A LIFT INVERTER SERIES L1000A EN DE For Modernization and New Installation YASKAWA L1000A FOR HIGH PERFORMANCE LIFT APPLICATION Contents Page 2 Experience & Innovation Page 3 Main Features Page 4 Energy

More information

THE NEW V1000 INVERTER 1 0 x = 1

THE NEW V1000 INVERTER 1 0 x = 1 THE NEW V1000 INVERTER 1 0 x 1 0 0 = 1 D e s i g n e d f o r :» 1 0 y e a r s l i f e t i m e» 1 0 0 % ex p e c t a t i o n m a t c h» 1 i n 1 0,0 0 0 f i e l d f a i l u re ra t e Quality has a new formula

More information

Q2A. System configuration

Q2A. System configuration Q2 riving Quality dvanced motor control for IM, PM & SynRM motors Open/closed loop speed or torque control Embedded functional safety (STO SIL3) Built-in C3 class EMC filter Conform to EN 60721-3-3, 3S2

More information

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

RM B. Features. Drive Model Number Scheme. A RM6 Product Series Features RM6 series are suitable for constant and variable torque loads (mixer, conveyor, fan, pump, etc.) Overload capacity with 150% drive s rated output current for 1 min can sustain heavy load conditions

More information

MX2-Series V1 type. kw VT motor capacity

MX2-Series V1 type. kw VT motor capacity Multi-function Compact MX-Series V1 type With Machine Automation Mentality Positioning functionality. Fieldbus communications with optional unit *1 EtherCAT, CompoNet and DeviceNet Drive Programming. Current

More information

Multi-function Compact Inverter. MX2-Series V1 type. Born to drive machines. » Permanent magnet motors» EtherCAT.

Multi-function Compact Inverter. MX2-Series V1 type. Born to drive machines. » Permanent magnet motors» EtherCAT. Multi-function Compact MX-Series V1 type Born to drive machines» Permanent magnet motors» EtherCAT» Built-in safety Harmonised motor and machine control MOTOR CONTROL 00% starting torque Near stand-still

More information

3 Year. Warranty. Maximum Engineering for Global Advantage. The High Performance Multifunctional Inverter CEN-G1EN18.05

3 Year. Warranty. Maximum Engineering for Global Advantage. The High Performance Multifunctional Inverter CEN-G1EN18.05 3 Year Maximum Engineering for Global Advantage Warranty The High Performance Multifunctional Inverter CEN-G1EN18.05 Perfomance reaching the peak in the industry Why FRENIC-MEGA? Able to drive induction

More information

P-SERIES VFD WITH BYPASS

P-SERIES VFD WITH BYPASS P-SERIES VFD WITH BYPSS 1 40 HP (200~230 VC) 1 100 HP (380~480 VC), 3Ø Enclosed Bypass - UL Type 3R Standard Controls for Bypass & Local/Remote Operation Special Instructions: FETURES ND OPTIONS Compact

More information

Multi-function Compact Inverter. MX2-Series V1 type. Born to drive machines. »» Permanent magnet motors»» Drive Programming. »» Built-in safety

Multi-function Compact Inverter. MX2-Series V1 type. Born to drive machines. »» Permanent magnet motors»» Drive Programming. »» Built-in safety Multi-function Compact Inverter MX-Series V1 type Born to drive machines»» Permanent magnet motors»» Drive Programming»» Built-in safety Harmonised motor and machine control MOTOR CONTROL 00% starting

More information

Description 1/8-7.5HP

Description 1/8-7.5HP Description 1/8-7.5HP J1000 In our pursuit to create drives optimized for variable speed needs in compact applications, the J1000 is the solution. This micro-drive is simple and reliable with Yaskawa quality.

More information

5.1 Errors (Alarms) Error (alarm) definitions PROTECTIVE FUNCTIONS. (1) Major faults

5.1 Errors (Alarms) Error (alarm) definitions PROTECTIVE FUNCTIONS. (1) Major faults .1 Errors (Alarms) If any fault has occurred in the inverter, the corresponding protective function is activated and the error (alarm) indication appears automatically on the PU display. When the protective

More information

HIGH PERFORMANCE VECTOR CONTROL DRIVE

HIGH PERFORMANCE VECTOR CONTROL DRIVE JI350 SERIES IP 54 Drive for PMSM and IM Accuracy speed and torque control for motor VF control and vector control 180% rated starting torque Plug n play control box with emergency stop HIGH PERFORMANCE

More information

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

SINUS PENTA 2T/4T SINUS PENTA 2T/4T SINUS PENTA 2T/4T SINUS PENTA 2T/4T Technical Highlights One product, 5 integrated functions - IFD (Inverter Frequency Drive): vector modulation function for general-purpose applications (V/F pattern).

More information

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications Contents Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications.......... Dimensions........................... Page

More information

Unidrive M700 Class leading performance with onboard real-time Ethernet

Unidrive M700 Class leading performance with onboard real-time Ethernet Unidrive M Class leading performance with onboard real-time Ethernet. kw -.8 MW Heavy Duty (. hp -, hp) V V V 9 V Unidrive M features Easy click-in keypad connection Range of multi-language LCD keypads

More information

INVERTER SERIES HIGH PERFORMANCE VECTOR CONTROL A1000

INVERTER SERIES HIGH PERFORMANCE VECTOR CONTROL A1000 INVERTER SERIES HIGH PERFORMANCE VECTOR CONTROL EN DE YASKAWA HIGH PERFORMANCE DRIVE Contents Page 2 Experience & Innovation A leader in Inverter Drives technology Main Features Page 3 Customize Your Drive

More information

Shenzhen Sine Electric Co., Ltd.

Shenzhen Sine Electric Co., Ltd. Page 1 of 5 Favorite Contact 中文 Please enter key words 提交查 Home Products Solutions Service About us Products EM500 Open loop Inverter Your current location:home > Products Standard Inverters EM500 Open

More information

A V Class: ½ to 175 HP 480V Class: ½ to 1000 HP 600V Class: ½ to 250 HP

A V Class: ½ to 175 HP 480V Class: ½ to 1000 HP 600V Class: ½ to 250 HP A1000 240V Class: ½ to 175 HP 480V Class: ½ to 1000 HP 600V Class: ½ to 250 HP A single drive for all your needs, with outstanding performance and flexibility! The A1000 is a full-featured drive, providing

More information

RV SYSDrive AC Inverters

RV SYSDrive AC Inverters 7160_Omron 3/31/04 4:38 PM Page 1 OMRON IM ONTROLS, IN. RV SYSrive Inverters High-Value, 4-in-1 Inverter Solutions for General-Purpose & High-End pplications 7160_Omron 3/31/04 4:38 PM Page RV Inverter

More information

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive IP 0/NMA & IP 66/NMA 4X Compact Vector Control rive APPLICATIONS General multi-function model IP 0/NMA Textiles oodworking Small andling Machine Simple Metal Processing Machine Tools Packaging & Labeling

More information

3-phase 400 V 0.4 to 630 kw. High Performance Multifunctional Inverter

3-phase 400 V 0.4 to 630 kw. High Performance Multifunctional Inverter 3-phase 400 V 0.4 to 630 kw High Performance Multifunctional Inverter The performance reaching the peak in the industry The performance reaching the peak in the industry FRENIC-MEGA is a high performance,

More information

Technical Explanation for Inverters

Technical Explanation for Inverters CSM_Inverter_TG_E_1_2 Introduction What Is an Inverter? An inverter controls the frequency of power supplied to an AC motor to control the rotation speed of the motor. Without an inverter, the AC motor

More information

High on intelligence big on reliability AC Drive

High on intelligence big on reliability AC Drive High on intelligence big on reliability AC Drive Single-Phase 230V (0.75 ~ 3.7kW) Three-Phase 230V (0.75 ~ 18.5kW) Three-Phase 415V (0.75 ~ 90kW) Two decades of application knowledge For over two decades,

More information

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3 Type number key VFD 007 CP 43 Option cards A B C S -XY Y=0: UL open 1: NEMA1 X=0: IP00 2: IP20 Version number: A=Wall mount B=Higher rated current C=Cabinet S=Frame D0 Input voltage 23=230VAC 3φ 43=400VAC

More information

SD1 Series General Purpose AC Variable Speed Drives

SD1 Series General Purpose AC Variable Speed Drives 1 200/240V 50/60Hz 0.4~2.2kW (0.5~3HP) 3 200/240V 50/60Hz 0.4~7.5kW (0.5~10HP) 3 380/440V 50/60Hz 0.75~110kW (1~150HP) IP20 Torque Vector Control STO (safe torque off) Up to 150% Starting Torque Front

More information

Symbol Input rating Symbol 2 Three-phase, 200 ~ 230V N 4 Three-phase, 380 ~ 480V. None. Loader. Graphic. Loader

Symbol Input rating Symbol 2 Three-phase, 200 ~ 230V N 4 Three-phase, 380 ~ 480V. None. Loader. Graphic. Loader is7 Variable Frequency Drive / Inverter High Torque Performance and Precise VFD 3 phase 0.75~22kW(1~30HP), 200~230V 3 phase 0.75~160kW(1~250HP), 380~480V Constant torque / Variable torque dual rating Selectable

More information

MULTI LANGUAGE KEYPAD

MULTI LANGUAGE KEYPAD FREQUENCY INVERTER MULTI LANGUAGE KEYPAD E 800 E 2000 EP 66 EM 30 Universal remote keypad- display unit, compatible with all EURA Drives products Robust, for any critical environments, IP66 waterproof

More information

SYSDRIVE JX Series. Simple, Compact Inverters. Easy-to-Use Compact Simplified Inverter for the Customer's Environment and Application Demands

SYSDRIVE JX Series. Simple, Compact Inverters. Easy-to-Use Compact Simplified Inverter for the Customer's Environment and Application Demands Simple, Compact Inverters SYSDRIVE JX Series CSM_3G3JX_DS_E_1_1 Easy-to-Use Compact Simplified Inverter for the Customer's Environment and Application Demands Provides a wide ranging capacity from 0.2

More information

V1000. AC Drive Series.

V1000. AC Drive Series. V1000 AC Drive Series www.yaskawa.eu.com One for all The V1000 is a compact general purpose AC drive covering the demands of a wide range of applications. Simple duties as well as requirements of complex

More information

Introduction. Getting Started. Main Features. Introduction

Introduction. Getting Started. Main Features. Introduction 1 In This Chapter... page Introduction... 2 L100 Inverter Specifications... 5 Introduction to Variable-Frequency Drives... 17 Frequently Asked Questions... 22 1 2 Introduction Introduction Main Features

More information

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:

More information

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Presentation Soft starters 0 Altistart 48 soft start - soft stop units Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled

More information

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool FR VARIABLE SPEED DRIVES Regenerative Active Front End icool 4 QUADRANT POWER ELECTRONICS / SD700 SERIES FR SD700FR SERIES goes one step ahead keeping the family unique characteristics. Based on the latest

More information

INVERTER FR-A800 Plus

INVERTER FR-A800 Plus FACTORY AUTOMATI INVERTER FR-A800Plus The optimum functions for cranes are added. for CRANES Reduction in tact time Load slippage prevention Dedicated monitoring functions Applicability in a wide range

More information

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA SmartVFD HVAC APPLICATION The SmartVFD HVAC is a variable frequency drive designed for use in HVAC application to control the speed of HVAC pumps and fans in order to maximize energy efficiency. Smart

More information

BR Second Position Voltages. AA Fourth Position

BR Second Position Voltages. AA Fourth Position 1336S First Position Bulletin Number BR Second Position Voltage Letter AQ BR CW A B BP BX C Q R RX W Voltages 200-240V AC or 3V DC 380-480VAC or 513-620V DC 500-600V AC or 775V DC or 200-240V AC 380-480V

More information

New. High Performance Inverter FUJI INVERTERS 24A1-E-0042

New. High Performance Inverter FUJI INVERTERS 24A1-E-0042 High Performance Inverter New FUJI INVERTERS The FRENIC-Ace is the inverter that produces excellent cost-performance; maintains high performance through optimal design. In this way, it can be applied to

More information

YASKAWA AC Drive High Performance Vector Control A1000

YASKAWA AC Drive High Performance Vector Control A1000 YASKAWA AC Drive High Performance Vector Control A1000 200 V CLASS, 0.4 to 110 kw 400 V CLASS, 0.4 to 630 kw Certified for ISO9001 and ISO14001 JQA-0422 JQA-EM0498 The Birth of Yaskawas Ace Drive Offering

More information

ADJUSTABLE FREQUENCY CRANE CONTROLS

ADJUSTABLE FREQUENCY CRANE CONTROLS IMPULSE G+ MINI ADJUSTABLE FREQUENCY CRANE CONTROLS The IMPULSEG+ Mini from Magnetek continues our history of providing the most reliable and cost-effective adjustable frequency crane controls available.

More information

V1000. YASKAWA AC Drive. Compact Vector Control Drive

V1000. YASKAWA AC Drive. Compact Vector Control Drive Compact Vector Control Drive YASKAWA AC Drive V1000 200 V CLASS, THREE-PHASE INPUT: 0.1 to 18.5 kw 200 V CLASS, SINGLE-PHASE INPUT: 0.1 to 3.7 kw 400 V CLASS, THREE-PHASE INPUT: 0.2 to 18.5 kw So advanced!

More information

Standard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes

More information

V1000. YASKAWA AC Drive Compact Vector Control Drive

V1000. YASKAWA AC Drive Compact Vector Control Drive YASKAWA AC Drive Compact Vector Control Drive V1000 200 V CLASS, THREE-PHASE INPUT: 0.1 to 18.5 kw 200 V CLASS, SINGLE-PHASE INPUT: 0.1 to 3.7 kw 400 V CLASS, THREE-PHASE INPUT: 0.2 to 18.5 kw So advanced!

More information

E5CSV temperature controller

E5CSV temperature controller ECSV temperature controller R e a d y, s e t, g o!» P e r f e c t c o n t ro l» Easy setting u p» E n h a n c e d f u n c t i o n a l i t y Advanced Industrial Automation Perfect temperature control in

More information

HVAC Products. Introducing the SED2 Variable Frequency Drives

HVAC Products. Introducing the SED2 Variable Frequency Drives HVAC Products Introducing the SED2 Variable Frequency Drives Designed Specifically for HVAC Applications From a global leader in drives technology and innovation, now comes a drive specifically configured

More information

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide Retain for future use. 30072-450-47A July 2002 Raleigh, NC, USA HAZARDOUS VOLTAGE Read and understand

More information

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase Variable Frequency Drive Moving your Control NEW! Forward VFD from Unitronics 0.4-2.2kW Single Phase 0.75-110kW Three Phase Total Solution All-in-One software PLC programming HMI design NEW! VFD configuration

More information

VSD Series II Variable Speed Micro Drives

VSD Series II Variable Speed Micro Drives VSD Series II Variable Speed Micro Drives Product Bulletin Code No. LIT-12011813 Issued March 26, 2013 Refer to the QuickLIT website for the most up-to-date version of this document. Johnson Controls VSD

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

690+ Series Integrator

690+ Series Integrator 690+ Series Integrator V/F, Sensorless, Vector Inverter from 1 to 1600 DESCRIPTION The 690+ Series is a single range of AC drives designed to meet the requirements of all variable speed applications from

More information

pag. 5 pag. 8 Who we are: evolution sectors pag. 11 pag. 14 Designation pag. 27 Versions pag. 18 pag. 31 Accessories and Options pag.

pag. 5 pag. 8 Who we are: evolution sectors pag. 11 pag. 14 Designation pag. 27 Versions pag. 18 pag. 31 Accessories and Options pag. 1 2 1 pag. 4 2 pag. 5 3 pag. 7 4 pag. 8 Who we are: evolution Introduction Industry sectors Plus & Benefit 5 pag. 10 6 pag. 11 7 pag. 12 8 pag. 14 Designation Compliance Directives and Standards Operating

More information

CTi Automation - Phone: Fax: Web:

CTi Automation - Phone: Fax: Web: CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility

More information

SHENZHEN KEWO ELECTRIC TECHNOLOGY CO., LTD

SHENZHEN KEWO ELECTRIC TECHNOLOGY CO., LTD SHENZHEN KEWO ELECTRIC TECHNOLOGY CO., LTD KEWO AC DRIVES, VARIABLE FREQUENCY DRIVE, FREQUENCY INVERTER ADD: 3 Floor,Block 8,St George Industrial Park,Xinyu Road,Sha Jing,Bao'an, Shenzhen, Guangdong, China,518104.

More information

Customized drive solutions

Customized drive solutions Customized drive solutions Altivar 680 low-harmonic drive system 150 900 hp ND/125 700 hp HD altivardrives.com 2 altivardrives.com altivardrives.com 3 What will you get with drive systems? Whatever you

More information

YASKAWA AC Drive Compact V/f Control Drive J1000

YASKAWA AC Drive Compact V/f Control Drive J1000 YASKAWA AC Drive Compact V/f Control Drive 200 V CLASS, THREE-PHASE INPUT: 0.1 to 5.5 kw 200 V CLASS, SINGLE-PHASE INPUT: 0.1 to 2.2 kw 400 V CLASS, THREE-PHASE INPUT: 0.2 to 5.5 kw Reliable and Smart

More information