1 Section 22 Expansion Vessels, Air Separators & Air Vents
2 EXPANSION VESSELS, AIR SEPARATORS & AIR VENTS Flamco Expansion Vessels Flexcon Vessels for Heating & Chilled water systems sizes 8-80 litres Vessel Clench Ring S Steel Epoxy Powder Coated Butyl Rubber Steel Zinc Coated MAX Temp at Heating Outlet MAX Temp at 3 Bar 70 C Flexcon Type C SIZE LITRES DIA HEIGHT APPROX KG MOUNTING FLEV8/ Wall mount-use MB2 Clip or Flexconsole FLEV12/ Wall mount-use MB2 Clip or Flexconsole FLEV18/ Wall mount-use MB2 Clip or Flexconsole FLEV25/ Wall mount-use MB2 Clip or Flexconsole FLEV35/ Foot mount FLEV50/ Foot mount FLEV80/ Foot mount SIZE LITRES Flexcon Type P Side Mount DIA HEIGHT APPROX KG MOUNTING FLEVP18/ Side mount FLEVP25/ Side mount FLEVP35/ Side mount FLEVP50/ Side mount Flamco Expansion Vessels Flexcon Vessels for Heating & Chilled water systems sizes litres Vessel S Steel Epoxy Powder Coated Butyl Rubber MAX Temp at Heating Outlet MAX Temp at 6 Bar 70 C Flexcon SIZE LITRES DIA HEIGHT APPROX KG FLEV110/ FLEV140/ FLEV200/ FLEV300/ FLEV425/ FLEV600/ FLEV800/ FLEV1000/ ASMUSS
3 Flamco Automat for Large Systems Giving Precise Control Compressor Driven Automatic Expansion Control System comprises: Vessel, Compressor Unit & Controller Expansion Capacity from 400 to 3,500 Litres EXPANSION VESSELS, AIR SEPARATORS & AIR VENTS Flamco Flamcomat Multi Function System Pump Driven Automatic Expansion Control, Pressurisation, De-aeration & Makeup System comprises: Vessel, Pump Unit & Controller Expansion Capacity from 150 to 10,000 Litres Flexcon Tank Mounting Options FLWM27913 MB2 wall Mounting Clip VESSELS 2-25 litres FLWM27910 Flexconsole VESSELS 8-25 litres Flexconsole Plus VESSELS FLWM litres Complete with: gauge, Auto Air Vent, Safety valve, Self Isolating Union
4 EXPANSION VESSELS, AIR SEPARATORS & AIR VENTS Flamco Flexvent Automatic Air Vent S Float Plastic Shut off valve /Butyl Rubber 10 Bar Flamco Flexvent SIZE DIA HEIGHT APPROX KG FLAV/ FLAV/ Flamco Prescor Safety Valves Pre-set, Membrane Seal, Quick Release, Non-Adjustable S Reinforced Hi Temp Rubber MAX 140 C SIZE INLET/ OUTLET Flamco Funnel/Tundish Used on the outlet of all Safety Relief Valves as an Air Break & Visual Inspection Prescor Safety Relief valves HEIGHT SET PRESSURE BAR HEATING CAPACITY KW APPROX KG FLSV / FLSV / FLSV / FLSV / FLSV / FLSV / Prescor Safety Relief valves INLET OUTLET HEIGHT APPROX KG FLF/ FLF/ FLF/ FLF/ ASMUSS
5 Automatic Fill Set Comprising: Reducing Valve, Check Valve, 2 Ball Valves & Flex Hose EXPANSION VESSELS, AIR SEPARATORS & AIR VENTS Reducing valve Check Valve Ball valves Flex Hose S Rubber inner SS outer MAX Inlet Outlet Adjustable 15 Bar 1 to 4 bar 80 C Automatic Fill set SIZE LENGTH HEIGHT APPROX KG FLAF/ Flamco / Gauge Complete with Immersion Fitting & Shut Off valve Automatic Fill set PRESSURE RANGE TEMPERATURE RANGE FLPGTG/ Bar 20- Flamco Gauges PRESSURE RANGE Automatic Fill set MOUNTING FACE FLPG 0-4 Bar 8mm Bottom Entry 63mm FLPG Bar 8mm Bottom Entry 63mm Flamco Flexfast Isolating Union Enables disconnecting the vessel without draining the system or releasing the pressure FLEX27920 Flamco Flexfast Isolating Union Suitable for vessels up to 25 litres Has 20mm internal & 20mm external thread
6 EXPANSION VESSELS, AIR SEPARATORS & AIR VENTS Flamcovent Micro-Bubble Air Separators For total evacuation of air from heating & cooling systems using Pall Rings & Coalescence Principle S Pall Rings SS 10 Bar Flamcovent Air Separator SIZE FACE TO FACE HEIGHT APPROX KG FLAS/ FLAS/ FLAS/ FLAS/ Flamcovent F Air Separator Flanged SIZE FACE TO FACE HEIGHT APPROX KG FLAS/ FLAS/ FLAS/ FLAS/ FLAS/ FLAS/ FLAS/ Flamco Flexair Air Separators For evacuation of air from heating & cooling installations using Centrifuge Principle Suitable for systems with high flow rates up to 5 m/s, & for Glycol solutions up to 50% Flexvent S Steel Epoxy Powder Coated Ends Flanged PN10 10 Bar Flexair Air Separator SIZE FACE TO FACE HEIGHT APPROX KG FLEXAIR FLEXAIR FLEXAIR FLEXAIR ASMUSS
7 Flamcovent Clean Air & Dirt Separators Specially designed to remove solid particles as well as air from heating systems EXPANSION VESSELS, AIR SEPARATORS & AIR VENTS S Steel Epoxy Coated Flexvent Ends Flanged PN10 10 Bar Flamcovent Clean F SIZE FACE TO FACE HEIGHT APPROX KG FLASC/ FLASC/ FLASC/ FLASC/ FLASC/ FLASC/ FLASC/ Flexfiller Digital Pressurisation Units Compact totally enclosed units with user friendly microprocessor for use with Flexcon Expansion Vessels. Provides a minimum system pressure requirement. The processor allows for low & high pressure monitoring & system diagnostics. Single or Dual Pump (standby) options. Compact wall or floor mount styles. Integral water break tank. Low water pump protection. Alarms for high & low water pressure. Output pressures up to 8 bar. Top up flow rates from 0.4 L/min to 30 L/min. Optional RS485 connectivity for use with BMS. Flamco products are available in solar options for high temperature service
8 EXPANSION VESSELS, AIR SEPARATORS & AIR VENTS Flamco Dosing Pot For chemical dosing of heating & cooling systems with manual air bleed valve. Valve S Mild Steel 90 C 16 Bar BODY HEIGHT Flamco Dosing Pot BRACKET WIDTH CONNECTIONS APPROX KG FLDPOT mm 16 FLDPOT mm 20 FLDPOT mm 23 FLDPOT mm ASMUSS
Safety Valves. Prescor Safety valves for sealed heating and cooling installations. Set pressures from 1.5 bar - 5 bar. Peak load: 140 C.
Safety Valves Prescor Safety valves for sealed heating and cooling installations. Set pressures from 1.5 bar - 5 bar. Peak load: 140. Full stroke safety valve ccording to TR 721-6 directive. Spring loaded,
More information1. Expansion Vessels. We reserve the right to change designs and technical specifications of our products.
. Expansion Vessels Flamco produces a comprehensive range of diaphragm expansion vessels. oth the steel vessel and the diaphragm are of the highest quality. They are compliant with all prevailing European
More informationFlamcomat Pump Sets, operating range. System Pressure P [bar] Boiler Output [MW] / Cooling Capacity [MW] = Boiler Output x 2.42
Single pump control (PN 10) Single pump powered controll unit for Flamcomat expansion automats. To be completed with a Flamcomat main vessel and optionally Power : 230V / 1ph / 50Hz (L1, N, PE). Pressure
More informationFlamco Pressurisation Equipment
Flamco Pressurisation Equipment Flamcomat Balance spill & fill Equipment Spare part list We reserve the right to change designs and technical specifications of our products. Rev 1.0 Jun-18 Page 1 / 13
More informationDatasheet. Flamcomat - Pressureless Expansion System
Flamcomat - Pressureless Expansion System The Flamcomat balanced pressure expansion equipment is sized according to the total system volume and the boiler / chiller load. The Flamcomat vessel is 80% efficient
More informationMATERIAL. Hand Wheel Ductile Iron Threading ISO 228 MATERIALS. Hand Wheel Ductile Iron MATERIALS. Stem 316 Stainless Steel MATERIALS.
Valves COMMODITY VALVES A-Gate Gate Valve - AGVFF S Bonnet Wedge Hand Wheel Ductile Iron ing ISO 228 180 C 16 bar 15-100 NB DZR Gate Valve - MVBGT S DR Bonnet DR Wedge DR DR Hand Wheel Ductile Iron Packing
More informationPHP-C Pressureless Expansion System Overview Description: The PHP-C balanced pressure expansion equipment is sized according to the total system volume and the boiler or chiller load. The PHP-C vessel
More informationFlamcomat Pump Sets, operating range. System Pressure P [bar] Boiler Output [MW] / Cooling Capacity [MW] = Boiler Output x 2.42
Single control (PN 6) Flamcomat Pump Sets, oating range Boiler Output [MW] / Cooling [MW] = Boiler Output x 2.42 Single powered controll unit for Flamcomat expansion automats. To be completed with a Flamcomat
More informationVenting Range and Air/Dirt. Separators
Venting Range and ir/irt Separators Separators Venting Range and ir/irt + Systems in which the water is properly deaerated and free of contamination are more efficient, produce less noise and have a longer
More informationRESOL SBS 1000 * * Connection Operation
RESOL SBS 1000 Connection Operation FlowCon SBS 1000 A www.resol.de *48003820* 48003820 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this
More informationCompresso. Pressure maintenance systems with compressors. engineering ADVANTAGE
Compresso Pressure maintenance systems with compressors Pressurisation & Water Quality alancing & Control hermostatic Control engineering ADVANAE Compresso is a precision pressurisation system with compressors
More informationMild Steel Dosing Pots
Mild Steel Dosing Pots Data Sheet Features Introduction Materials of Construction Most heating and chilled water systems require chemical dosing and the BOSS range of Dosing Pots provides a controlled
More informationRecirculating Coolers
SELECTION GUIDE (General Models) (Low Temp. Models) (Advanced Low Temp. Models) (High Temp. Models) General Models Low Temp. Models Advanced Low Temp. Models High Temp. Models HX-20 Working Cooling Temp.
More information548 hydraulic separator
hydraulic separator 120 C 120 105 C 105 120 Serie 548 120 C 105 C 105 548 imensions C B Function The ltecnic 548 hydraulic separator combines several different components, each of which performs a specific
More informationProviding a constant temperature control and high cooling efficiency.
Recirculating Coolers (General) Providing a constant temperature control and high cooling efficiency. Performance Temperature range from 3 to 40. High cooling capacity up to 7.1kW at 20. Powerful circulating
More informationEach pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.
General 1 Model MS 9-2-60 expandable/modular duplex central vacuum system consisting of two Becker or approved equivalent VT4.25 vacuum pumps mounted on a common skid with expandable automatic alternating
More informationabc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.
CPD7948/075 Specification Oil-Free, Air Cooled, Rotary Screw Compressors - Dryclon Range Models D75, D90, D110, D132, D150 (50Hz) D55, D75, D90, D110, D150 (60Hz) COMPRESSOR PACKAGE An enclosed two stage
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More information40 geothermal ground loop manifolds
40 geothermal ground loop manifolds GeoCal (key features listed left) This is the first thermoplastic, fully modular manifold system designed specifically for installations using ground source heat pumps.
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationThe pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.
General Model MS150-4-150 expandable/modular central vacuum system consisting of 4 Becker or approved equivalent KVX3.140-400 vacuum pumps mounted on a common skid with expandable automatic alternating
More informationAir Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.
Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water
More informationThe pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.
1 General Model MS100-3-60 expandable/modular duplex central vacuum system consisting of two Becker or approved equivalent KVX 3.140/1-400 vacuum pumps mounted on a common skid with expandable automatic
More informationHot-Tap Machines. Specification Sheet TBL Bulletin nº: SPECIFICATION FOR TBL-0322 TAPPING MACHINE Tapping Range 1 through 6
Bulletin nº: 2009.602.00 Specification Sheet TBL-0322 SPECIFICATION FOR TBL-0322 TAPPING MACHINE Tapping Range 1 through 6 Boring Bar Travel 32 (813 mm) Standard Auto Feed 0.006 per rev. (0.15 mm per rev.)
More informationSolar Thermal. Grant Solar Pump Station Installation & Servicing Instructions
Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant
More informationPRESSURE CONTROL VALVES SABS 198
PRESSURE CONTROL VALVES SABS 198 1 CALVALVE DOUBLE BLOCK Pressure control combined pressure reducing valve and expansion relief valve, copper by copper compression ends. DZR alloy body. Replaceable cartridge
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationSBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual
SBS 2000 Filling and flushing station Manual for the specialised craftsman Connection Operation Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from
More informationECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES
ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES TECHNICAL AND INSTALLATION DOCUMENTATION STOKVIS ENERGY SYSTEMS UNIT 34 CENTRAL PARK ESTATE 34 CENTRAL PARK ESTATE WEST
More informationEach pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.
1 General Model MS300-4-530 expandable/modular central vacuum system consisting of 4 Becker or approved equivalent VTLF2.250 vacuum pumps mounted on a common skid with expandable automatic alternating
More informationExpansion Vessel BS1
Datasheet Expansion Vessel BS1 Our stainless steel expansion vessels are a high quality product, thanks to the s used offering maximum guarantee for hygiene, resistance to corrosion and durability. They
More informationW91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer
Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY
More informationChiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.
Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.
More informationSeries Cantilever Liquid Level Control
Series Section No. 3. Application Cantilever liquid level control series offers design simplicity, easy installation, adjustment, and reliable liquid level monitoring. It is a highly efficient device for
More informationUltra-compact, variable speed twin and triple pump booster sets
Ultra-compact, variable speed twin and triple pump booster sets Product Overview Compact footprint designed to fit through a standard door All wetted parts manufactured with stainless steel No hidden extras
More informationGH Hydro Kits. Technical Information. Ref: N
GH Hydro Kits Ref: N-27167 0507 Technical Information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products are as listed in the EUROVENT Directory
More informationInstallation manual. Cooling system. Industrial engines DC09, DC13, DC16 OC16. 01:05 Issue 12 en-gb. Scania CV AB 2018, Sweden
Installation manual Cooling system Industrial engines DC0, DC13, DC OC 333 3 01:05 Issue en-gb Changes from the previous issue...3 Design and dimensioning...3 Expansion tank...4 and earlier emission levels...
More informationZX6 INTRODUCTION ZX6 HOIST 2 : 1 4 : 1. Rope Reeving. Speeds 4/1.3 m/min 5/1.6 m/min 6/2 m/min 8/2.6 m/min. Lift 6.5m 10m 15m
ZX HOIST ZX6 INTRODUCTION ZX6 HOIST The ZX6 Model is available with 4 gearbox ratio s, 3 drum lengths & 2 different reeving arrangements. These options combine to provide a comprehensive range of hoists
More informationInstallation instruction
1 Safety Before installing the device, please read this manual carefully. Please note that the installation must be executed according to relevant technical rules. The installation must also be adapted
More informationAir-to-water heat pump for indoor installation - LIK 8TES. Spare parts list
Spare parts list Brand: Dimplex Type: LIK 8TES Part number: 366030 Position Description Part number Serv. ind. 1 Compressor 4522354115 2 Evaporator 4521612802 3 Expansion valve 4521614106 4 Inspection
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationThe Mikrofill Electronic Filling Device. (EFD)
The Mikrofill Electronic Filling Device. (EFD) The Mikrofill EFD is a fully automatic sealed system filling device, and is suitable for the water management in all domestic and commercial heating and cooling
More informationPRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES
WATER METERS VALVES & COCKS PRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES FILTER, REGULATOR & LUBRICATORS W IKA V I INSTRUMENTS
More informationLUBRICATION PUMP UCF CENTRAL LUBRICATION
LUBRICATION PUMP APPLICATION Lubrication pumps are used as a source of pressure lubricant for lubricating systems equipped with progressive distributors for permanent, regular lubrication of various machines,
More informationSINUS VERTEILER PRODUCT GUIDE
SINUS VERTEILER PRODUCT GUIDE 2017/18 heating heating & cooling & cooling systems systems 1 CUSTOMER CARE EXPORTS The product configurator Stefan Engberding Head of Exports Phone: +49 (0) 2557 / 93 93-62
More informationKS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors
Engineering Submittal Sheet Installation Sets for Collectors Layout legend S Supply from collector to storage R Return from storage to collector 1 Ball valve with thermometer and integrated gravity break
More informationMcQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors
McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors Applied Systems - Strategic Marketing Contents 1. Introducing WMC 1.1 Product Overview 2010 1.2 Range 2. Technical
More informationHTX-HTH SEPARATORS I&O MANUAL
INSTALLATION OPERATIONS AND MAINTENANCE HTX-HTH SEPARATORS I&O MANUAL 1365 N. Clovis Avenue Fresno, California 93727 (559) 255-1601 www.lakos.com LS-714B (Rev. 11/17) TABLE OF CONTENTS Table of Contents...
More informationCATÁLOGO TÉCNICO COMERCIAL
CATÁLOGO TÉCNICO COMERCIAL ENFRIADORAS DE AGUA CONDENSADAS POR AIRE Series LCAEX De 350 a 1600 Kw. Compresor de tornillo R-134A Index Identification code Identification code and index... pag. 2 General
More informationRemove and install steering gear
ZF Aftermarket Neuwied Remove and install steering gear JRB5090 PUBLICATION XZB3502EN NOTE Secure vehicle against rolling away. Ensure proper cleanliness when working on the servo-steering. Cable connections
More information51 minim and duco magnetic filters for system treatment
Magnetic filters for heating systems 51 minim and duco magnetic filters for flush out or drain! see fluid condition so you know when to order a system clean upper chamber position to demagnetise & flush
More informationData Sheet No 241 Jan 2002 Issue G. Electrode Holders & Brackets for Conductivity Type Systems
HAWKER Data Sheet No 4 Jan Issue G LEVEL CONTROL SYSTEMS Holders & Brackets for Conductivity Type Systems Heavy Duty HPE8 Heavy Duty HPE8/P Heavy Duty E holder suitable for sewage, water and effluent applications.
More informationVERTICAL IN-LINE PUMP
VERTICAL IN-LINE PUMP TECHNICAL FEATURES ELINE: Vertical centrifugal pumps, single impeller, volute casing, non-self priming pump, in-line executive, with mechanical seal. Hydraulically designed in line
More informationHydraulic primary unit Type ABPAG
RE 51 018/11.02 Replaces: 07.96 Hydraulic primary unit Type PG Reservoir volumes 63 to 400 litres Maximum operating pressure 360 bar H 2375 Type PG.. Overview of contents Contents Page Features 1, 2 Ordering
More informationLSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS
Air/water chillers and heat pumps LSE Outdoor packaged unit LSE 60-00 kw Multi-scroll solutions for reliability and high efficiency at partial loads Scroll compressor PLUS R-0A R-0A refrigerant Cooling
More informationWater pumps for Desalination APP 16-22
Data sheet Water pumps for Desalination APP 16-22 ro-solutions.com APP16-22 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater reverse osmosis filtration
More informationOPERATION AND INSTALLATION
OPERATION AND INSTALLATION RESIDENTIAL SOLAR PUMP STATION» SE FLOWSTAR PUMP STATION Table of Contents 1 For your safety 1.1 About this manual 1.2 Designated use 1.3 Qualification of the installer 1.4 Hand-over
More informationEP series WPS150BS-AU rpm,3-phase/5-wiring
EP series WPS150BS-AU 50 Hz @ 1500rpm,3-phase/5-wiring 1 Standards & Conditions Design Standards The designs and the productions are in conformity with: Conformite Europeenne (CE) China Compulsory Certification
More informationMATERIALS FILTER ELEMENTS SEPARATION CAPACITY CARTRIDGES PRESSURES VALUES
INTRODUCTION FAI FILTRI high quality standards has allowed the production of air/oil separator for air purification into rotary/vane compressors. This has to be considered as a fundamental premise for
More informationSection - B. Air vents
Section - Air vents AIR VENTS EXAMPLE OF APPLICATION 2 1 2 4 5 2 3 3 4 6 1 Automatic air vent valves. 2 Manual air vent valves. 3 Air vent valves with adjustable discharge nozzle. 4 Air vents with float..
More informationZeparo G-Force. Automatic air vents and separators Microbubble, dirt and magnetite separator with Cyclonic technology
Zeparo G-Force Automatic air vents and separators Microbubble, dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo G-Force Zeparo G-Force
More informationProduct Data Sheet. Part Number: Gen 3 Frame LH Fill. Product Technical Specifications
Part Number: 116883 Part Description: Fuel Storage Module (FSM) Gen 3 Frame LH Fill Product Technical Specifications General Specifications Designed Location... Frame Rail Mount (FRM) Gasoline Gallon Equivalancy
More informationPNEUMATICALLY ACTUATED 2-WAY
482 DN 25-65 The 482 diaphragm valve is particularly suitable for shutting off and regulating abrasive or dirty fluids. The new internal geometry of the body optimises fluid dynamic efficiency by increasing
More informationYCUJ Millennium TM AIR COOLED CONDENSING UNIT
YCUJ Millennium TM AIR COOLED CONDENSING UNIT REFRIGERANT R407C COOLING CAPACITIES 348 kw to 760 kw The YCUJ range of Condensing Units are designed for direct expansion cooling and are usually used in
More informationLAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C
LAUDA Integral Process thermostats for professional external thermostating across a wide temperature range from -9 up to C Application examples Process technology Process engineering Production Research
More informationLAB EQUIPMENTS. Manufacturing & Servicing of:
Manufacturing & Servicing of: LAB EQUIPMENTS OVERHEAD STIRRER MAGNETIC STIRRER LAB OIL BATH LAB OIL BATH WITH MAG. STIRRER TEMPERATURE CONTROLLER MULTI CHANNEL TEMP. INDICATOR LAB CENTRIFUGE We Service
More informationValves Range YSTF Y-Strainer PN16 Flanged. Applicable Standards. Technical Data. Material Certification
Valves Range YSTF Y-Strainer PN16 Flanged No Component Material 1 Body Ductile iron GGG40 2 Bonnet Ductile iron GGG40 3 Screen SS304 4 Gasket EPDM 5 Washer 140HV 6 Drain Plug KTH330-08 7 Nut Gade 8.8 8
More informationSEASONAL MAINTENANCE CHECKLISTS Johnson Controls
SPRING CHECK LIST ABSORPTION CHILLERS Check starter and control panel. Leak test. Check hand valve diaphragms and replace as required. Check operation of purge unit. Change oil in the purge pump. Lubricate
More informationWater Cooled Air Compressors. The most convenient, efficient and effective way to cool your high pressure compressor.
Water Cooled Air Compressors The most convenient, efficient and effective way to cool your high pressure compressor. Rev. 04.19 NUVAIR WATER COOLED MCH13 / MCH16 COMPRESSOR FEATURES Cools each stage to
More informationProcess screen basket filter PRFS
Process screen basket filter PRFS PRFS- PRFS- PRFS- PRFS- PRFS- PRFS- 130x 250x 520x 650x 1500x 2500x Nominal size: Q s max: p s max: Filtration ratings: Specifications DN 50 DN 700 3600 m³/h 16 bar 25
More information485 - NC NO/DA DN
485 - NC 285 - NO/DA DN 25-100 The 485/285 diaphragm valve is particularly suitable for shutting off and regulating abrasive or dirty fluids. The new internal geometry of the body optimises fluid dynamic
More informationMicro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange
Can separate and remove aerosol state oil mist in compressed air and remove particles such as carbon or dust of more than 0.01 μm. Use this product as a pre-filter for compressed air for precision instruments
More informationVIESMANN VITOTRANS 100 Plate heat exchanger
VIESMANN VITOTRANS 100 Plate heat exchanger Datasheet Part numbers and prices: see pricelist VITOTRANS 100 Type PWT For transfer stations from heat supply networks, for system separation in heating systems
More informationBioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced
1 Data Sheet Bioengineering RALF Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. The glass vessels have both a round bottom and stainless steel lid. The system
More informationList Price Sheet January 6, 2017
Sheet January 6, 2017 300 Pond Street (800) 527-0030 Randolph, MA 02368 www.flexconind.com Flexcon Steel Well Tanks Materials of Construction Top and bottom domes: 16 gauge cold rolled steel Outer Shell:
More informationblasting equipment Elcometer RCV4000 Remote Control Valve Quickly cuts off the flow of compressed air to the blast hose
Remote Control Valve Remote Control Valves are used to safely pressurise and depressurise abrasive blast machines at the blast nozzle using a deadman s handle. Quickly cuts off the flow of compressed air
More informationLUBRICATION PUMP ACF CENTRAL LUBRICATION
LUBRICATION PUMP APPLICATION Lubricators are used as a pressure lubricant source for lubricating systems with progressive distributors for permanent, regular lubrication of various machines and equipment.
More informationCBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet
CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that
More informationInstallation instructions. Cascade unit. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)
Installation instructions Cascade unit For wall hung gas-fired condensing boiler GB162-50/65/80/100 6 720 648 720-000.1TD UK/IE 6720813173 (2014/09) Product overview Product overview 9 1 7 A2 5 A1 B2 B1
More informationVT Oil-Free Range Operators Handbook
VT Oil-Free Range Operators Handbook Covering Models:- VT7 / VT7D VT10 / VT10D VT200 / VT200D VT300 / VT300D VT00 / VT00D BAMBI AIR COMPRESSORS LTD 12 Thimble Mill Lane Heartlands Birmingham B7 HT Tel:
More informationPIPING PACKAGES For Chilled and Hot Water Fan Coil Units
WWW.KRUEGER-HVAC.COM PIPING PACKAGES For Chilled and Hot Water Fan Coil Units PROVIDING YOU WITH AIR DISTRIBUTION AND EQUIPMENT SOLUTIONS TABLE OF CONTENTS General Notes... 4 Code Descriptions... 5 Guide
More informationSPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM
SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM 1.0 GENERAL 1.1 DESCRIPTION A. Manufacturer shall furnish an aspirating directional aerator (aspirator) or a high-flow directional aerator
More informationINSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components
7EN www.caleffi.com Circulation units for solar thermal systems Copyright Caleffi 7HE - 79HE series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Product range Technical specifications Characteristic
More informationPOWERBOOST. PRO Range. Clean Water Booster Sets. powerboost.ie
PRO Range Clean Water Booster Sets 1 powerboost.ie The POWERBOOST Range EPS introduces the POWERBOOST range of clean water booster sets for the supply of water for commercial, industrial and municipal
More informationMAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com
MAKING MODERN LIVING POSSIBLE Data sheet Data sheet APP 11-13 ro-solutions.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Technical data...4 4. Variants...4 5. Flow at different rpm....5
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationGMK EV SERIES. Single Stage Oil Sealed Rotary Vane Pump
GMK EV SERIES Single Stage Oil Sealed Rotary Vane Pump EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum needs. Eurovacuum
More informationDS Series Solar System
DS Series Solar System Permit information Consol 30-58-1800 Collector Flat mount on Colorsteel Plumdeck roofing Valve vent, Open loop http:// www.consolsolar.co.nz 21 Page 1 of This system is an evacuated
More informationPIPING PACKAGES TABLE OF CONTENTS
PIPING PACKAGES TABLE OF CONTENTS ITEM PAGE General Notes and Legend........................................................ 3 Piping Package Code Descriptions & Diagrams VAV Products and HL, HP, VF, and
More information30-450kW. Now Available. Ultima Compact Chiller Range kW. > Ultima Compact Chiller Range. Free-Cooling models up to 450kW.
30-450kW 0-450kW Free-Cooling models up to 450kW Now Available > Ultima Compact Chiller Range Typical Applications > Precision Air Conditioning Cooling > Comfort Cooling > Process Cooling www.airedale.com
More informationType TSF2 CNG FUTURE. TECHNOLOGY. TODAY. Coalescing Filter. Data sheet. for installation onboard CNG vehicles and in fuelling stations
Data sheet D-2011/05/00160-3-3 Date: 02/2013 Type TSF2 CNG Coalescing Filter for installation onboard CNG vehicles and in fuelling stations FUTURE. TECHNOLOGY. TODAY. General Description Features Fine
More informationInstallation Instructions. Vitosol 100. Vitosol 100 Type w 2.5 Flat collector for flat roofs and freestanding installation Part No.
Installation Instructions Vitosol 100 Type w 2.5 Flat collector for flat roofs and freestanding installation Part No. 3001 970 Vitosol 100 8/99 Safety instructions This hazard symbol precedes all important
More informationInline version with application-specific process adaptation
Pneumatic Retractable Fittings hem Energy Pharm Food Water eramat WA 50 Inline version with application-specific process adaptation Facts for extreme applications ceramic sealing to the process: extremely
More informationSecondary Coolant 301
Secondary Coolant 301 Instructor Rusty Walker Hill PHOENIX Learning Center Secondary Coolant 301 Start-Up Procedures Secondary Coolant 301 Objectives Describe the initial startup procedures for a medium
More informationVerifiable and Zero Leakage Design. PosiWell Pte Ltd. No. 9A Joo Koon Crescent Singapore Registration No N. Innovation By Design
Verifiable and Zero Leakage Design PosiWell Pte Ltd Asia Pacific Regions Europe / USA Regions No. 9A Joo Koon Crescent Singapore 629023 Registration No. 201221185N Alfred Tan Leon Niessen PosiWell patented
More informationPROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL
PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL 1.1 SUMMARY A. Packaged Chillers offer a self-contained means of producing cooling liquid primarily
More informationMVD, MV, MKV, MKL, 2161C, MXV Series
MVD, MV, MKV, MKL, 2161C, MXV Series Float-type air vent valves Technical Data Sheet WattsIndustries.com Description DUOVENT MVD and MVDR Series, MINIVENT MV and MVR Series, MICROVENT MKV, MKVR, MKL and
More informationHYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.
HYDRAULIC SEPARATOR CT0617.0_03 EN March 2016 o o o Threaded versions equipped with flat seat F union connections, therefore, easy installation and/or maintenance; Self-cleaning: Dirt separator equipped
More informationNew Fan Coil Piping Packages
New Fan Coil Piping Packages SO BUILT TOUGH, TOUGH. WE BUILT GUARANTEE TO LAST. IT. www.superiorrex.com Piping Packages Table of Contents General Notes and Legend... 3 Piping Package Code Descriptions
More informationCATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.
CATALOG Actuated Diaphragm Valve DN 15-100 PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL. TABLE OF CONTENTS Type 186 - DN 12-15 (MA 10) 04 General information - Technical specification 04 Sectional
More information