Safety Valves. Prescor Safety valves for sealed heating and cooling installations. Set pressures from 1.5 bar - 5 bar. Peak load: 140 C.

Size: px
Start display at page:

Download "Safety Valves. Prescor Safety valves for sealed heating and cooling installations. Set pressures from 1.5 bar - 5 bar. Peak load: 140 C."

Transcription

1 Safety Valves Prescor Safety valves for sealed heating and cooling installations. Set pressures from 1.5 bar - 5 bar. Peak load: 140. Full stroke safety valve ccording to TR directive. Spring loaded, directly activated. Set pressures from 1 bar - 10 bar. 3. ccessories for Heating and ooling Installations Flopress Safety valves for sealed heating and cooling installations. Set pressures from bar. Prescor Solar Safety valves for sealed solar installations. ccording to TÜV. SV SOL. Working temperatures from -30 up to 160 peak load. Prescor S Safety valve for sealed heating and cooling installations. With connections from 1¼" up to 2" these valves are ideal for protecting larger commercial installations. Red brass safety valve For sealed heating and solar systems. Safety valve For closed refrigeration, cooling and air conditioning systems. Prescomano Safety valves with pressure gauge (0-4 bar). For sealed heating and cooling installations. Peak load: 140. Flopressmano Safety valves with pressure gauge (0-4 bar). For sealed heating and cooling installations. Funnel Fitted between the Prescor safety valve and the discharge pipe. Flamco has a complete range of products for safeguarding chilled and heating systems. The various models of Flamco Prescor safety relief valves are used around the world to prevent overpressure in sealed systems. The Flexalance and Flexalance Plus are an excellent solution for preventing hydraulic imbalance in sealed systems. Pressure gauges and filling assemblies of various types are also available. 92

2 ccessories for Heating and ooling Installations 3 Prescofiller Filling and safety group suitable for smaller domestic installations. ombination of Prescor safety valve, Flexcon pressure gauge and a fill and drain set. Prescomano and ball valve are supplied separate from the T-piece and fill and drain set so that mounting in any position is made possible. Manofiller Filling group suitable for mounting on a radiator. Ideal for installations in which the pressure gauge has been installed in close proximity of the boiler but filling of the installation has to take place elsewhere (e.g. bathroom). May be mounted in any position. Safety Sets Flexcon KSG Safety set with safety valve, Flexvent and pressure gauge. Including insulation. Safety Set ¾ Safety set with safety valve, Flexvent and pressure gauge Safety Set 1 ¼ Safety set with safety valves (2), Flexvent and pressure gauge. Safety Set SG Safety set with safety valve and pressure gauge. Safety Set rmature rmature for mounting a pressure gauge and safety valve. Pressure Gauges Pressure gauge For monitoring system pressure. Flexcon pressure gauges (80 mm dia.) can be installed without depressurising or draining the system thanks to the self closing shut off valve. Thermo pressure gauges For monitoring system pressure and system temperature. xial connection. onnection Sets and Isolating Unions Flexontrol The Flexontrol connects the Flexcon expansion vessel with the central heating system. nables checking the pre-charge of the Flexcon expansion vessel and topping up the system. nables replacing the expansion vessel without depressurising or draining the system. Flexfast ¾" Quick disconnect coupler for checking the pre-charge of the Flexcon expansion vessels up to 25 litres. nables replacing the expansion vessel without depressurising or draining the system. Flexcon onnection group ½" For connecting expansion vessels to a heating or cooling system. onsists of a shut-off valve, a fill and drain set with hose connections and pressure gauge. Flexcon onnection Group 1" For connecting expansion vessels to a heating or cooling system. onsists of a shut-off valve, fill and drain set with hose connection and pressure gauge (0-12 bar). Wall Mounting Flexconsoles For mounting Flexcon 8-25 vessels to a wall. vailable in red or white color. Supplied with or without accessories. Wall mounting bracket M For easy connecting Flexcon and irfix / 8-25 litres vessels to a wall. ubex R racket For mounting ubex R litres vessels to a wall. osing Pots osing pots For dosing sealed heating or chilled systems with chemical additives. In mild steel or stainless steel. Hydraulic alancers Flexalance S/F/R qualizes hydraulic imbalance between primary and secondary circuits. Internal perforated flow reduction plate. Supplied with automatic float vent. Flexalance Plus S/F/R qualizes hydraulic imbalance between primary and secondary circuits. With PLL-rings. Supplied with automatic float vent and a drain valve. Flexbalance coplus qualizes hydraulic imbalance inbetween primary and secondary circuits. Supplied with automatic float vent and a drain valve. PUR hard foam insulation mantle. System ccessories WMS / WMS- Mechanical or lectronic low water level protection device. For monitoring system pressure and system temperature. Maximum pressure: 10 bar. Uni-Fill Filling Sets Full sets of fittings to meet water bye-laws for temporary connection to the water mains. Strainers Standard Y pattern with removable mesh cartridge for easy cleaning. ccessories for the Installer Flexcon GV 90 Gas valve extension bent at 90 to increase accessibility of Flexcon gas valves. Flexcon rain Tub Handy accessory for draining low positioned tap points. Flexcon T For unmounting Flexcon and irfix vessels. Suitable for 2-25 litre vessels. Precharge pressure tester For testing pre-charges of Flexcon and irfix expansion vessels. Pressure range bar. Vessel arrier For easy and safe handling and transporting the exchanged vessel. 93

3 Prescor Safety Valves: omplete Range for the Safety of Your System If you are looking for reliable safety valves you need look no further than Flamco's Prescor range. The best protection for all sealed heating and chilled systems from overpressure. The Prescor valves are suitable for systems with a capacity of up to 580 kw at 3.0 bar. Systems with greater capacity will need the heavy-duty Prescor S. The enefits of Prescor High-quality materials and construction guarantee reliable function. If there is a rapid build-up of pressure, the valve will 'pop' open. The pressure can then be discharged quickly. conformity mark (P 2014/68/U). The opening pressure of all valves is individually tested. ap of high-impact plastic. nti-ageing spring steel prevents the set pressure from drifting. Robust brass housing. The diaphragm prevents moisture and dirt from getting into the moving parts of the safety valve during blowing off. Valve seal of high-quality rubber, heat-resistant to 140 º. The hardness of the rubber is adapted to the set pressure of the valve. These properties mean that the valve will not stick to the valve seat. PRSOR ll Prescor safety valves are set to the specified opening pressure during manufacture. This setting cannot be adjusted. It is important to check the requirements for the Prescor valve in advance. When choosing a Prescor safety valve the capacity shown on the safety valve must exceed the nominal boiler capacity. Mount on the boiler, or as close as possible to it, in the supply line. Never fit a stopcock between the boiler and the valve. 94

4 ccessories for Heating and ooling Installations 3 Prescor S Safety Valves With connection dimensions of 1 1 /4" up to and including 2", these valves are the ideal safeguard for larger systems. More than one Prescor S safety valve may be fitted to a system so that it can meet the required capacity if the applicable regulations allow. Prescomano handy Prescor safety valve and Flexcon pressure gauge in one. Lifting lever. Spring for setting the pressure. This setting is locked. Prescor S type plate showing the set pressure and the maximum boiler capacity for which the valve is suitable. onnet and body made entirely of brass. iaphragm that protects the spring, preventing water leakage via the spindle. Valve with seal of special rubber. rass valve seat. How a Prescor works PRSOR S The sealed system when cold. When the system heats up, the water inside will expand. The pressure in the system rises. The Prescor valve opens. The excess pressure is discharged. 95

5 SFTY VLVS Prescor safety valves have a special shape which, not only achieves a perfect seal, but also a large blow off capacity. The valve seal is made of high quality rubber which is heat resistant to 140, and where the hardness of the rubber adjusts to the set pressure of the safety valve. In this way, the valve cannot stick to the seat. ll valves are tested before they leave our facility and are available for heating and cooling installations as well as for protection of various hot water storage appliances. For safety valves for potable water installations see "ccessories for Sanitary Installations". Prescor Min./Max. working temperature: -10 / 120. Peak load: 140. G F Set pressure onnection imensions Heating capacity [kw] Prescor 1 / Rp 1 / 2" Rp 1 / 2" Prescor 1 / Rp 1 / 2" Rp 1 / 2" Prescor 1 / Rp 1 / 2" Rp 1 / 2" Prescor 1 / 2 M 3.0 R 1 / 2" Rp 1 / 2" Prescor 1 / 2 M x K R 1 / 2" K Prescor 1 / 2 M x K R 1 / 2" K Prescor 1 / Rp 1 / 2" Rp 1 / 2" Prescor 3 / Rp 3 / 4" Rp 3 / 4" Prescor 3 / Rp 3 / 4" Rp 3 / 4" Prescor 3 / Rp 3 / 4" Rp 3 / 4" Prescor 3 / Rp 3 / 4" Rp 3 / 4" Prescor 3 / 4 M x K R 3 / 4" K Prescor 3 / 4 M x K R 3 / 4" K Prescor 3 / 4 M x K R 3 / 4" K Prescor 3 / 4 M x K R 3 / 4" K Prescor 3 / 4 M x K R 3 / 4 " K Prescor 3 / Rp 3 / 4" Rp 3 / 4" Prescor 1 / 2 NF 3.0 Rp 1 / 2" Rp 1 / 2" Prescor 1 / 2 M NF 3.0 R 1 / 2" Rp 1 / 2" Prescor Rp 1" Rp 1 1 / 4" Prescor Rp 1" Rp 1 1 / 4" Prescor Rp 1" Rp 1 1 / 4" Prescor Rp 1" Rp 1 1 / 4" Prescor Rp 1" Rp 1 1 / 4" Prescor Rp 1" Rp 1 1 / 4" Prescor 1 1 / Rp 1 1 / 4" Rp 1 1 / 2" Prescor 1 1 / Rp 1 1 / 4" Rp 1 1 / 2" Prescor 1 1 / Rp 1 1 / 4" Rp 1 1 / 2" Prescor 1 / 2 * 2.5 Rp 1 / 2" Rp 3 / 4" Prescor 1 / 2 * 3.0 Rp 1 / 2" Rp 3 / 4" Prescor 3 / 4 * 3.0 Rp 3 / 4" Rp 1" Prescor 3 / 4 * 2.5 Rp 3 / 4" Rp 1" Prescor 1 * 3.0 Rp 1" Rp 1 1 / 4" Prescor 1 * 2.5 Rp 1" Rp 1 1 / 4" Prescor 1 1 / 4 * 2.5 Rp 1 1 / 4" Rp 1 1 / 2" Prescor 1 1 / 4 * 3.0 Rp 1 1 / 4" Rp 1 1 / 2" Prescor N 25-2,5 bar 2.5 Rp 1" Rp 1 1 / 4" Prescor N 20-2,0 bar 2.0 Rp 3 / 4" Rp 3 / 4" * Manufactured according to TR directives. F G 96

6 Flopress Min./Max. working temperature: -10 / 120. ccessories for Heating and ooling Installations 3 Set pressure onnection imensions Heating capacity [kw] Flopress 1 / 2 x 1 / bar 2.5 Rp 1 / 2" Rp 1 / 2" Flopress 1 / 2 x 1 / bar 3.0 Rp 1 / 2" Rp 1 / 2" Flopress 1 / 2 M x 1 / bar 3.0 R 1 / 2" Rp 1 / 2" Flopress 1 / 2 x 3 / bar 3.0 Rp 1 / 2" Rp 3 / 4" Flopress 3 / 4 x 3 / bar 1.5 Rp 3 / 4" Rp 3 / 4" Flopress 3 / 4 x 3 / bar 2.5 Rp 3 / 4" Rp 3 / 4" Flopress 3 / 4 x 3 / bar 3.0 Rp 3 / 4" Rp 3 / 4" Prescor Solar Specially designed for solar installations. Min./Max. working temperature: -30 / 120. Peak load: 160. Suitable for addition of glycol-based anti-freeze up to 50%. G F Set pressure onnection imensions Heating capacity [kw] Prescor Solar 1 / Rp 1 / 2" Rp 3 / 4" Prescor Solar 1 / Rp 1 / 2" Rp 3 / 4" Prescor Solar 1 / Rp 1 / 2" Rp 3 / 4" Prescor Solar 3 / Rp 3 / 4" Rp 1" Prescor Solar 3 / Rp 3 / 4" Rp 1" Prescor Solar 3 / Rp 3 / 4" Rp 1" Prescor Solar Rp 1" Rp 1 1 / 4" Prescor Solar Rp 1" Rp 1 1 / 4" Prescor Solar Rp 1" Rp 1 1 / 4" F G 97

7 Prescor S For sealed central heating and chilled water (cooling) installations. Min./Max. working temperature: -10 / 120. Suitable for addition of glycol-based anti-freeze up to 50%. Sealing sets (100 pieces per bag) for appendages, such as the Flexcontrol or Prescor S, can be ordered separately. F Set pressure onnection imensions Heating capacity [kw] Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / / 4" F 1 1 / 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / G 1 1 / 2" F G 2" F Prescor S / 2 * 2.5 G 1 1 / 2" F G 2" F Prescor S / 2 * 3.0 G 1 1 / 2" F G 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S G 2" F G 2 1 / 2" F Prescor S * 2.5 G 2" F G 2 1 / 2" F Prescor S * 3.0 G 2" F G 2 1 / 2" F Flamco Seals Service Set * Produced according to TR directives. F 98

8 Full-stroke safety valve Produced according to TR directives. ast iron body (PN 10). ccessories for Heating and ooling Installations 3 X H F Set onnection imensions Weight pressure F H X [kg] [N] [N] Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve 20 * Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve 25 * Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve 32 * Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve 40 * Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve 50 * Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve Full-stroke safety valve 65 * Full-stroke safety valve 80 * Full-stroke safety valve 100 * Full-stroke safety valve 125 * Full-stroke safety valve 150 * * Specify set-pressure when ordering between 1.0 bar and 10.0 bar. 99

9 Selection Table for full-stroke safety valve (capacity In kw) Set-pressure onnection N 20 N 25 N 32 N 40 N 50 N 65 N 80 N 100 N 125 N Red rass Safety Valve For closed heating systems with supply temperatures up to 120 according to TR 721 (IN 4751) and solar systems. Set pressure onnection Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve " F x 1 1 / 2" F Safety valve 1 * 1" F x 1 1 / 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / / 4" F x 2" F Safety valve 1 1 / 4 * 1 1 / 4" F x 2" F * Specify set-pressure when ordering between 1.0 bar and 10.0 bar. 100

10 Safety valve For closed refrigeration, cooling and air conditioning systems. ccessories for Heating and ooling Installations 3 Min./Max. working temperature: -10 / 120. Peak load: 140. ctuation pressure onnection Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / / 2" F Safety valve 1 / 2 * 1 / 2" F * Specify set-pressure when ordering between 1.0 bar and 16.0 bar. Prescomano Safety valves with pressure gauge for sealed central heating and chilled water (cooling) installations. Min./Max. working temperature: -10 / 120. Peak load: 140. G F Set pressure onnection imensions Heating capacity [kw] Prescomano 1 / 2 * 2.5 Rp 1 / 2" Rp 3 / 4" Prescomano 1 / 2 * 3.0 Rp 1 / 2" Rp 3 / 4" Prescomano 1 / Rp 1 / 2" Rp 1 / 2" Prescomano 1 / 2 NF 3.0 Rp 1 / 2" Rp 1 / 2" Prescomano 3 / Rp 3 / 4" Rp 3 / 4" * Produced according to TR directives. F G 101

11 Flopressmano Safety valves with pressure gauge for sealed central heating and chilled water (cooling) installations. Min./Max. working temperature: -10 / 120. Set pressure Inlet ["] onnection Outlet ["] Heating capacity [kw] Flopressmano 1 / 2 x 1 / 2-3 bar NF / 2" F 1 / 2" F Flopressmano 1 / 2 x 1 / 2-3,0 bar / 2" F 1 / 2" F Tundish Fitted between the Prescor safety valve and the discharge pipe. It enables you to check through the opening whether the safety valve is discharging excess water. onnection pplication imensions Tundish 1 / 2 (brass) 1 / 2" M 1 / 2" F Prescor 1 / 2", Prescomano 1 / 2", Prescor 1 / 2" Tundish 3 / 4 (brass) 3 / 4" M 1" F Prescor 1 / 2", Prescor 3 / 4", Prescomano 3 / 4", Prescor Solar 1 / 2" Tundish 1 (cast iron) 1" M 1 1 / 2" F Prescor 3 / 4" TR, Prescor Solar 3 / 4" Tundish 1 1 / 4 (cast iron) 1 1 / 4" M 1 1 / 2" F Prescor 1", Prescor Solar 1" Tundish 1 1 / 2 (cast iron) 1 1 / 2" M 1 1 / 2" F Prescor 1 1 / 4", Prescor S 1 1 / 4" FILLING VIS Prescofiller omestic heating system filling device with safety valve and pressure gauge 0-4 bar. Min./Max. working temperature: -10 / 120. Peak load: 140. Set pressure Inlet onnection Outlet Heating capacity [kw] Prescofiller / 2" M 1 / 2" F Manofiller omestic heating system filling device with pressure gauge 0-4 bar. Min./Max. working temperature: -10 / 120. Peak load: 140. onnection Manofiller 1 / 2" M

12 ccessories for Heating and ooling Installations Prescor Safety Valves: wide product range for every demand 3 103

13 SFTY STS Flexcon KSG Suitable for sealed heating and cooling systems. Working temperature: -10 / 90. Max. boiler capacity: 70 kw. Medium: water and water/glycol solutions up to 50%. Safety valve: ½" x ¾", 2.5 bar (110 kw). Flexvent ⅜" with shut-off valve. Pressure gauge: Ø 61mm, 6.0 bar with shut-off valve. Insulation: material PP - color: black. Set pressure onnection Heating capacity [kw] Flexcon KSG 3 / 4 coplus 2.5 Rp 3 / 4" Safety Set ¾ Set pressure onnection Heating capacity [kw] Safety Set 3 / / 4" Safety Set SG Set pressure onnection Safety Set SG 3 / bar 1.5 G 3 / 4" F Safety Set SG 3 / 4 x 22mm bar 1.5 G 3 / 4" F x 22 mm Safety Set SG 3 / 4 x 22mm bar 2.0 G 3 / 4" F x 22 mm Safety Set SG 3 / 4 x 22mm bar 2.5 G 3 / 4" F x 22 mm Safety set 1 ¼ Set pressure onnection Heating capacity [kw] Safety set 1 1 / / 4" Safety Set rmature onnection Safety Set rmature G 3 / 4" F

14 PRSSUR GUGS ccessories for Heating and ooling Installations 3 Pressure Gauges The pressure in the installation is indicated by the pressure gauge. onnection Pressure range Marking Shut-off valve Pr. gauge Ø 40 ax. for Prescomano 1 / 4 ax no Pr. gauge Ø 40 ax. for Prescomano N 10 ( 1 / 8) ax no Pr. gauge Ø 63 rad. / 4.0b. 1 / 4 rad no Pr. gauge Ø 63 rad. / 3.0b. 3 / 8 rad no Pr. gauge Ø 63 rad. / b. 3 / 8 rad no Pr. gauge Ø 63 ax. / 6.0 b. 1 / 4 ax no Pr. gauge Ø 63 rad. / b. 3 / 8 rad no Pr. gauge Ø 63 rad. / b. 3 / 8 rad no Pr. gauge Ø 63 rad. / b. 3 / 8 rad no Pr. gauge Ø 63 rad. / 2.5b. 3 / 8 rad no Pr. gauge Ø 63 ax. / b. 3 / 8 ax no Pr. gauge Ø 63 ax. / 3.0b. 1 / 4 ax no Pr. gauge Ø 80 rad. / 3.0b. 1 / 4 rad / 4" x 1 / 2" Pr. gauge Ø 80 ax. / 3.0b. 1 / 4 ax / 4" x 1 / 2" Pr. gauge Ø 80 rad. / 3.0b. 1 / 2 rad no Pr. gauge Ø bar rad. 3 / 8" rad no Manometer Ø 50 exc. 1 / 8" ax. not central no Manometer Ø 50 exc. 1 / 8" ax. not central 0-12 variable no Manometer 40 mm 1 mtr capillair 1 / 4" ax. cap. conn. 0-6 Flexibel capillair 2mm à 1 mtr no Thermo Pressure Gauges The combined pressure/thermo gauge shows not only the pressure, but also the temperature. O-ring 32 onnection Range Marking Thermo pressure gauge ax. (with shut-off valve) R 1 / 2" M / 0-4 bar Thermo pressure gauge ax. M 18 x 1" / 0-4 bar Thermo pressure gauge ax. (with shut-off valve) R 1 / 2" / 0-4 bar Shut-off Valves For pressure gauges. Self sealing by means of a PTF ring. onnection Shut-off valve 1 / 4 x 1 / 2 1 / 4" x 1 / 2" Shut off valve M18 x 1 / 2 M 18 x 1 / 2" Ø 105

15 Quickly onnect, isconnect and Inspect Flexcon xpansion Vessels Flexcon vessel can be directly connected to a pipeline. However, it is easier to use one of the Flexfast quick-release couplings, Flexcontrols, Flexconsoles or Flexcon connection groups shown here. These products make it easier to read off the pressure or to disconnect the vessel without having to drain the system or release the pressure. Flexconsole Plus complete product for hanging expansion vessels up to 25 litres attached to the water supply and to the wall. Supplied with: Flexcon pressure gauge. Flexvent floatvent. Safety valve. Flexfast quick-release coupling. Fixing set. Flexontrol M For easy disconnection of Flexcon vessels without having to drain the vessel or release pressure. FLXONSOL PLUS FLXONTROL M Flexconsole This version is supplied with a ½" radiator cap plus manual de-aerator. FLXONSOL FLXFST ¾" Flexfast Flexfast quick-release couplings make the process of checking the initial pressure of Flexcon vessels up to and including 25 litres quick and easy and also enable you to change the vessel without having to release pressure or drain it. asy to assemble with the right tools; then just screw in the components by hand. Saves a considerable amount of time when servicing a Flexcon vessel. Version with ¾" internal thread and ¾" external thread. 106

16 ccessories for Heating and ooling Installations 3 Flexcon onnection Groups Flamco offers two versions of its Flexcon connection groups. The Flexcon connection group ½" is suitable for Flexcon expansion vessels from 35 to 300 litres and systems up to 660 kw. The Flexcon connection group 1" is suitable for Flexcon expansion vessels from 110 to 1,000 litres and systems up to 2355 kw. Flexcon connection groups include a drain tap and a lockshield valve. fter the valve has been shut off the vessel can be drained, inspected or replaced. The Flexcon connection group ½" can be fitted to the expansion line whereas the 1" version must be fitted to the water nipple of the Flexcon vessel. Valve with safety sleeve. Flexcon pressure gauge, Ø 50 mm (0-12 bar). Installation connection. Swivel coupling for attachment to the vessel. all valve for filling and draining, with hose coupling and cap. FLXON ONNTION GROUP 1" Valve closed. Valve open. Valve open. Valve closed. Vessel connected to the system. FLXFST ¾" Vessel disconnected from the system. FLXON- ONNTION GROUP ½" 107

17 ONNTION STS N ISOLTING UNIONS Flexontrol This isolating union connects the expansion vessel to the central heating system and enables verification of the vessel s gas charge or, alternatively, allows you to replace it without draining the entire system. Maximum operating pressure: 10.0 bar. Maximum working temperature (design): 130. Sealing sets (100 pieces per bag) for appendages, such as the Flexcontrol or Prescor S, can be ordered separately. onnection imension Weight [kg] Flexontrol 3 / 4 M R 3 / 4" Rp 3 / 4" Flexontrol 3 / 4 Rp 3 / 4" G 3 / 4" F Flexontrol 1 Rp 1" G 1" F Flamco Seals Service Set Flexfast ¾ This isolating union makes it possible to check quickly and easily if a Flexcon expansion vessel is still working correctly (gas charge) or if it needs to be replaced. Material: rass. Suited for glycol mixtures of max. 50%. Working temperature range: -10 up to 90 continuous. Working pressure range: bar. onnection imension Flexfast 3 / 4 R 3 / 4" G 3 / 4" F

18 Flexcon onnection Group ½ - with pressure gauge ccessories for Heating and ooling Installations ,5 94,5 61 onnection With pressure gauge Flexcon connection group 1 / 2 R 1 / 2" / K15 * R 1 / 2" / K15* 3 / 4" yes * ompression connection. Flexcon onnection Group 1 lock and bleed valve for Flexcon litre expansion vessels. The set consists of a shut-off valve, a fill/drain tap with hose nipple and pressure gauge ( bar) Ø50 onnection With pressure gauge Flexcon connection group 1 1" F 1" F yes raided hose SST For easy connection of the expansion vessel to the central heating system. onnection Length Internal Ø Weight [kg] raided hose SST 3 / 4 3 / 4" F x 3 / 4" M raided hose SST 1 1" F x 1" M

19 WLL MOUNTING For mounting a Flexcon expansion vessel (2-25 litres) to a wall. Flexconsole ¾ With the Flexconsole the Flexcon vessel is set up vertically fitted to the water connection with the water nipple fitted on the ¾" connection of the console and the expansion pipe fitted to the ½" connection. quipped with a wall plate with two slots for accurate wall mounting. ø42 onnection imensions Flexconsole 3 / 4 x 1 / 2 Rp 1 / 2" Rp 3 / 4" Flexconsole 3 / 4 x 1 / 2 white Rp 1 / 2" Rp 3 / 4" Flexconsole 3 / 4 x 3 / 4 Rp 3 / 4" Rp 3 / 4" Floconsole Suitable for Flamco expansion vessels from 8-25 litres. The Floconsole comprises a 15 mm system connection compression fitting, a 3 /4" threaded expansion vessel connection and a manual de-aeration valve. Flexfast isolating union (27920) may be added as an optional extra. onnection imensions Floconsole 3 / 4 x 15 mm red 15 3 / 4" Floconsole 3 / 4 x 15 mm white 15 3 / 4"

20 ccessories for Heating and ooling Installations Flexconsole Plus s the conventional Flexconsole but also with a Flexcon pressure gauge with shut off valve, a Flexvent float vent with shut off valve, a safety valve set to 3.0 bar, and a Flexfast shut off valve. 3 F G 119 ø42 89 onnection imensions F G Flexconsole Plus Rp 3 / 4" G 3 / 4" F Flexconsole Plus 3 / 4 x 3 / 4 without Flexfast Rp 3 / 4" Rp 3 / 4" Flexconsole S 20 G F ø42 onnection imensions F G Flexconsole S 20 Rp 3 / 4" Rp 3 / 4" Rp 3 / 8" R 3 / 4"

21 Flexconsole Plus S 20 s the conventional Flexconsole S 20 but also with a Flexcon pressure gauge with shut off valve, a Flexvent float vent with shut off valve, a safety valve, and a Flexfast shut off valve. G F ø42 onnection imensions F G Flexconsole S 20 Plus bar 3 / 4" F 3 / 4" F R 3 / 8" R 3 / 4" Flexconsole S 20 Plus bar 3 / 4" F 3 / 4" F R 3 / 8" R 3 / 4" Flamconsole S 25 onnection Flamconsole S 25 Rp 3 / 8" Rp 3 / 8" R 1" Rp 1" G 1"

22 ccessories for Heating and ooling Installations M For mounting Flexcon/irfix vessels of 8-25 litres. Provided with a slot into which the Flexcon vessel clamp ring fits precisely. Tightening the two bolts is all that is needed to make a sturdy connection. 3 Material: 01 -m, zinc coated. onnection to the wall with two Ø8 plugs and two Ø6 screws with hexagon head (wrench 10). onnection of the vessel to the M by means of two M5 bolts with cross head. Separately available are sets of 5 hose clamps for connection vessels without clench ring (size approx. Ø 325 mm). M 3: With spring and adapter for easy mounting. imensions Flexcon vessel support M Flexcon vessel support M ubex R racket For easy connecting vessels to a wall. Suitable for ubex R vessel sizes: litres. Material: 12. Weight: 300 g. Mounting bracket zinc-plated. ubex R expansion vessels have to be installed with the system connector facing downwards. onnection to the clench ring of the vessel. onnection of the vessel to the mounting bracket by one M 8 x 45 bolt. imensions ubex R bracket

23 The solution for hydraulic imbalance in central heating installations Increasingly, heating installations are fitted with several boilers. s a result, individual boilers can be switched on or off, depending on the heating requirements. In addition, there are often multiple sub-systems fitted with individual pumps. With these systems there is a chance of hydraulic imbalance which will lead to poor heat transfer, overloading of pumps and a system that is difficult to stabilize. Using a Flexalance or Flexalance Plus hydraulic balancer prevents this problem and improves the efficiency of the system. ll Flexalance models are supplied with a high quality automatic air vent. Including PUR hard foam insulation mantle (Flexalance coplus only) With facility for temperature sensor. Flexalance coplus comes standard with pre-assembled, galvanized conical sealing connections (Rp) with connection sizes 1" to 2". very Flexalance Plus and Flexalance coplus is equiped with a dirt drainage tap. FLXLN OPLUS 1-2 FLXLN N FLXLN PLUS N50 - -N 125 How a hydraulic balancer works y fitting a Flexalance (Plus) hydraulic balancer, the primary and secondary circuits are disconnected and a balance is maintained between the various flow speeds. The flow in the primary and secondary circuits stays independent in all situations. This will give the system hydraulic balance (The flows in both sub-circuits are not influenced in any way.) Schematic illustration of a system with multiple boilers and pumps 114

24 ccessories for Heating and ooling Installations 3 Flexalance hydraulic balancer benefits No more overloaded pumps. Improved accurate regulation of the system is possible. onsiderably improved heat transfer. Higher output by the system. The best technology for every need! Two additional Flexalance functions Flexalance hydraulic balancers must be placed between the primary and secondary circuits to balance out both circuits. This is also the perfect place for air and dirt separation: With the high temperature water flowing through the supply connections this is the best possible point for air separation. irt separation takes place in the return connection, behind the radiators and immediately before the boiler thus protecting it from dirt. Flexalance and Flexalance Plus are available with connection sizes N 50 up to N 600 and with welded, flanged or grooved pipe system connections. N 150 and above: Supplied with feet. FLXLN N FLXLN PLUS N N 600 Thermal equilibrium Thermal input > demand Thermal input < demand 115

25 Flexalance Plus PLL ring technology For air and dirt separation the Flexalance Plus uses our patented PLL ring technology which has the following benefits: onical air chamber reduces risk of contamination of the valve. Shorter distance between supply and return connections. ven the smallest micro-bubbles and dirt particles are separated. Reduced flow-rate prevents heat exchange between the cold return water and the hot supply water and therefore considerably greater thermal yield than other hydraulic balancers on the market. rea where the microbubbles are collected. Red powder coated steel body. age with PLL rings for air (top) and dirt (bottom) separation. Sensor connection temperature sensor can be inserted in the sensor connection (G ½") with an immersion pipe. Inside the steel body the sensor connection ends directly in front of the exit of the supply water flow. rea where the dirt particles are collected. irt drainage tap for removing particles that are heavier than water. FLXLN PLUS Flow resistance Flexalance Flow resistance Flexalance Plus bar(g) kpa bar(g) kpa Pressure loss [kpa - bar] Pressure loss [kpa - bar] Flow [m³/h] Flow [m³/h] 116

26 ccessories for Heating and ooling Installations 3 Flexalance coplus : Unprecedented output and compact format This very efficient hydraulic balancer for heating systems ensures heat transfer of no less than 99%! ompared to comparable products this is more than twice as efficient! The inlets and outlets are connected in the bottle of the Flexbalance coplus by half-open pipes. This ensures that the upper or supply and lower or return flows stay balanced whilst thermal losses are minimized (no warming up of the return flow to the boiler). This immediately explains the unequalled output: the thermal exchange between the flows remains at a minimum. Moreover, the ingenious design ensures particularly low flow resistance. ompact. Heat transfer level of 99% (demonstrably the market leader). Low flow resistance. Flexvent Top W automatic air vent. Stepped galvanized connections Stepped connections make the bubbles bump against the wall of the bottle and coalesce. Immersion pipe for temperature sensor. Half open pipes t the top, the connection pipes open upwards, guiding the bubbles to the de-aerator. t the bottom they open downwards, guiding the dirt particles to the dirt separator. This also keeps the hot water in the upper section separate from the cold water beneath it. Insulation included. Incremental cross-wise plates irt particles that are in the water are captured between several incremental cross-wise plates under the pipe. irt drainage tap Pressure loss Flexalance coplus FLXLN OPLUS Pressure loss [N rukverschil 32 / 1m/s] (Pa) Flexalance coplus The most energy efficient hydraulic balancer in the market ue to the low flow resistance the Flexalance coplus has an extremely low difference in pressure before and after the hydraulic balancer. This in turn results in reduced pump energy consumption. Together with the excellent heat transfer of 99% this makes the Flexalance coplus by far the most energy efficient hydraulic balancer on the market

27 FLXLN OPLUS Flexalance coplus The Flexbalance coplus allows hydraulic separation between the primary and secondary circuits of commercial heating and cooling systems with air and dirt separation. Medium: Water and Water/glycol solutions up to 50%. Min./max. working pressure: bar. Min./max. operating temperature: -10 / 110. Intergration of air and dirt separation. Vessel: steel: red coated RL oupling (4x) with conical seal, galvanised steel. quipped with a Flexvent Top ⅜" white (28510). quipped with a brass drain valve ½" and hose connection. Insulation: material - PUR foam with two quick fasteners. λ: W/mK. Inner diameter 12.5 mm. I F G J Ø 14,5 onnection (4x) apacity [l] Max. power [kw] Flow rate [l/s] Kv * [m 3 /h] (ΔP = 1 bar) Length immersion pipe Weight [kg] Flexalance coplus 1 Rp 1" Flexalance coplus 1 1 / 4 Rp 1 1 / 4" Flexalance coplus 1 1 / 2 Rp 1 1 / 2" Flexalance coplus 2 Rp 2" * Kv = Q / ΔP Q: Flow [m 3 /h] ΔP: Pressure loss over the product Flow factor Kv: Rate of flow [m 3 /h] which results in a 1 bar pressure drop across the product. Flexbalance coplus - imensions imensions Flexalance coplus Flexalance coplus 1 ¼ Flexalance coplus 1 ½ Flexalance coplus F G I J 118

28 FLXLN HYRULI LNR ccessories for Heating and ooling Installations 3 For balancing hydraulic pressure in heating installations consisting of multiple circuits and pumps. Flexalance hydraulic balancers are supplied with an automatic air vent and have a connection for a temperature sensor. The sensor can be connected using an immersion pipe (G ½"). onventional VM hydraulic balancer. Min./max. working pressure: bar. Min./max. operating temperature: -10 / 120. Suitable for glycol solutions up to 50%. Maximum flow rate: Primary circuit: 2 m/s Secondary circuit: 1.2 m/s. Flexalance S With welding connections. H I apacity [l] onnection N apacity [kw] * Flow in the system [m 3 /h] Kv ** [m 3 /h] (ΔP = 1 bar) Weight [kg] Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S * epending on flow velocity. ** Kv = Q / ΔP Q: Flow [m 3 /h] ΔP: Pressure loss over the product Flow factor Kv: Rate of flow [m 3 /h] which results in a 1 bar pressure drop across the product. Flexalance S - imensions imensions Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S Flexalance S H I 119

29 Flexalance F With flanged connections. H I apacity [l] onnection N apacity [kw] * Flow in the system [m 3 /h] Kv ** [m 3 /h] (ΔP = 1 bar) Weight [kg] Flexalance F Flexalance F Flexalance F 65 *** Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F * epending on flow velocity. ** Kv = Q / ΔP Q: Flow [m 3 /h] ΔP: Pressure loss over the product Flow factor Kv: Rate of flow [m 3 /h] which results in a 1 bar pressure drop across the product. *** 4 hole flanged version. Not according to N PN16. Flexalance F - imensions imensions Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F Flexalance F H I 120

30 Flexalance R With grooved pipe system connections. ccessories for Heating and ooling Installations 3 H I apacity [l] onnection N apacity [kw] * Flow in the system [m 3 /h] Kv ** [m 3 /h] (ΔP = 1 bar) Weight [kg] Flexalance R Flexalance R Flexalance R Flexalance R Flexalance R Flexalance R Flexalance R * epending on flow velocity. ** Kv = Q / ΔP Q: Flow [m 3 /h] ΔP: Pressure loss over the product Flow factor Kv: Rate of flow [m 3 /h] which results in a 1 bar pressure drop across the product. Flexalance R - imensions imensions Flexalance R Flexalance R Flexalance R Flexalance R Flexalance R Flexalance R Flexalance R H I 121

31 FLXLN PLUS HYRULI LNR For balancing hydraulic pressure in heating installations consisting of multiple circuits and pumps. Flexalance Plus hydraulic balancers are supplied with an automatic air vent, a dirt chamber and a connection for a temperature sensor. The sensor can be connected using an immersion pipe (G ½"). The use of our patented PLL-ring technique enables a better response, returns higher efficiency, decreases total built-in height and shares its de-aeration and dirt separation benefits. onventional VM hydraulic balancer. Min./max. working pressure: bar. Min./max. operating temperature: -10 / 120. Suitable for glycol solutions up to 50%. Maximum flow rate: Primary circuit: 2 m/s Secondary circuit: 1.2 m/s. xcellent hydraulic control in combination with a large air and dirt separation capacity. Smaller construction height than standard hydraulic seperators. Flexalance Plus S With welding connections. H I apacity [l] onnection N apacity [kw] * Flow in the system [m 3 /h] Kv ** [m 3 /h] (ΔP = 1 bar) Weight [kg] Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S * epending on flow velocity. ** Kv = Q / ΔP Q: Flow [m 3 /h] ΔP: Pressure loss over the product Flow factor Kv: Rate of flow [m 3 /h] which results in a 1 bar pressure drop across the product. Flexalance Plus S - imensions imensions Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S Flexalance Plus S H I 122

32 Flexalance Plus F With flanged connections. ccessories for Heating and ooling Installations 3 H I apacity [l] onnection N apacity [kw] * Flow in the system [m 3 /h] Kv ** [m 3 /h] (ΔP = 1 bar) Weight [kg] Flexalance Plus F Flexalance Plus F Flexalance Plus F 65 *** Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F * epending on flow velocity. ** Kv = Q / ΔP Q: Flow [m 3 /h] ΔP: Pressure loss over the product Flow factor Kv: Rate of flow [m 3 /h] which results in a 1 bar pressure drop across the product. *** 4 hole flanged version. Not according to N PN16. Flexalance Plus F - imensions imensions Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F Flexalance Plus F H I 123

33 Flexalance Plus R With grooved pipe system connections. H I apacity [l] onnection N apacity [kw] * Flow in the system [m 3 /h] Kv ** [m 3 /h] (ΔP = 1 bar) Weight [kg] Flexalance Plus R Flexalance Plus R Flexalance Plus R Flexalance Plus R Flexalance Plus R Flexalance Plus R Flexalance Plus R * epending on flow velocity. ** Kv = Q / ΔP Q: Flow [m 3 /h] ΔP: Pressure loss over the product Flow factor Kv: Rate of flow [m 3 /h] which results in a 1 bar pressure drop across the product. Flexalance Plus R - imensions imensions H I Flexalance Plus R Flexalance Plus R Flexalance Plus R Flexalance Plus R Flexalance Plus R Flexalance Plus R Flexalance Plus R Spare vent cap L one-shaped air chamber equipped with a long float to create more distance to the vent valve. This reduces the risk of contamination of the valve seat to a minimum. Maximum system working pressure: 25 bar. Used for imensions Spare vent cap L Flamcovent (lean) N , Flamcovent (lean) Smart N , Flexalance (Plus)

34 OSING POTS ccessories for Heating and ooling Installations 3 osing pots are used for dosing sealed heating and chilled systems with chemical additives. Internally uncoated to guarantee chemical compatibility with standard installations. omplete with tundish, vessel, air vent, inlet, outlet and drain valves. Supplied fully assembled. Simple operations. Increases energy efficiency. xtends the life of the system. Min./Max. working temperature: 5 / 90. Mild Steel osing Pots Max. working pressure H. imensions System connections Weight [kg] osing pot 3.5 l " osing pot 6 l " osing pot 11 l " osing pot 18 l " osing pot 25 l " osing pot 35 l " osing pot 50 l " Stainless Steel osing Pots Ø Max. working pressure H. imensions System connections Weight [kg] Stainless steel dosing pot 3.5 l " Stainless steel dosing pot 6 l " Stainless steel dosing pot 11 l " Stainless steel dosing pot 15 l " Stainless steel dosing pot 18 l " Stainless steel dosing pot 25 l " Ø 125

35 Low Water Protection evices Low water level devices prevent the boiler from boiling dry. ccording to N 12828, system with more than 300 kw must be equipped with water level limiters. However, the installation of such units is recommended for all systems, especially when the heat source is at the top of the system. WMS 800 mechanical boiler water low level alarm with a float system. If the water level in the boiler drops below a minimum level a float activates a switch. This switch interrupts the power supply to the boiler burner. locking mechanism prevents the burner from restarting automatically. The test button allows the float to be lowered to simulate a low water alarm condition. The WMS 800 is suitable for continuous operation. Test button. designation plate. Re-set button. Vent screw. Weld connection piece. WMS 800 WMS- rass housing. Sludge opening. lectrode rod. Weld connection piece. Plastic housing. Weld connection piece. Green pilot lamp. Test button. Red alarm lamp. Release button rass housing. Weld connection piece. WMS- The WMS- boiler water low level alarm consists of a failsafe, self-monitoring control unit with a periodic self-test function and a sensor. The water shortage switch detects and signals low water levels. If the water level in the boiler drops below a minimum value the signal part interrupts the power supply to the boiler burner and activates the alarm indicator. The control unit and sensor are connected by a two-conductor signaling cable with a maximum length of 50 m. 126

36 SYSTM SSORIS WMS Low Water Level Protection evice Mechanical low water level protection device. ccessories for Heating and ooling Installations 3 F onnection * imensions F WMS 800 N 20 / G 1" M N 20 / G 1" M * compression/welding connection WMS- Low Water Level Protection evice lectronic low water level protection device. Maximum operating pressure: 10.0 bar. onnection (N 259) WMS- (220V - 1ph - 50Hz) R 3 / 4" Uni-Fil Filling Sets System connection Max. working pressure Uni-fil P Filling Loop 15 mm / 1 / 2" Uni-Fil auto 15 mm / 1 / 2" Strainers Standard 'Y' pattern with removable mesh cartridge for easy cleaning. rass body and stainless steel mesh. Ideal for many sealed applications. System imensions connection Y - 3 / 4" 3 / 4" F Y / 4" 1 1 / 4" F

37 Flamco makes assembly an easy job Flamco offers a series of tools and accessories to enable convenient, quick and simple assembly and that are indispensable for an installer. You can always rely on Flamco! FLXON GV 90 handy extension piece with a bend of 90. The Flexcon GV 90 can be screwed unto the gas valve of Flexcon 110-1,000 litres vessels. This extension piece makes the valve more easily accessible. FLXON RIN TU VSSL RRIR Receptacle for draining radiators that have low-installed drain points. Flexible in use. Including carabine hook for suspending it. Indispensable part for every installer. Made of high-quality SR rubber. Simplifies replacing and transporting Flexcon vessels of 2-25 litres. Prevents contaminated heating water from flowing out. The vessel can be moved using only one hand. Simple assembly and disassembly; can be used many times. FLXON T For supporting the assembly and disassembly of Flexcon and irfix vessels. Using the Flamco test manometer the pre-charge of Flexcon and irfix expansion vessels can be easily checked. Measuring range: bar. TST MNOMTR 128

38 SSORIS FOR TH INSTLLR ccessories for Heating and ooling Installations 3 Flexcon GV 90 Gas valve extension bent at 90 to increase accessibility of Flexcon gas valves. onnection Vessel Outlet Flexcon GV 90 Vg 8 F Vg 8 M Flexcon rain Tub The accessory for draining low positioned tap points. Flexible in use. With hook for easy storage. Vital for every installer. Made from high grade SR rubber. apacity [l] Ø imensions Weight [kg] Flexcon rain Tub ± Flexcon T To assist in mounting and removing Flexcon and irfix vessels. H. pplication imensions Flexcon T Flexcon/irfix Precharge Pressure Tester Pressure range Precharge tester ( bar) Vessel arrier handy vessel carrier which makes it very easy and safe to handle or transport the exchanged vessel. asy to use. Prevents spilling of (polluted) heating installation water in your transporter or at home with the customer. The vessel can be handled with one hand only. asy to be mounted and removed (for multiple use). onnection pplication Vessel carrier G 3 / 4" F Flexcon/irfix

Section 22. Expansion Vessels, Air Separators & Air Vents

Section 22. Expansion Vessels, Air Separators & Air Vents Section 22 Expansion Vessels, Air Separators & Air Vents 0800 276 877 297 EXPANSION VESSELS, AIR SEPARATORS & AIR VENTS Flamco Expansion Vessels Flexcon Vessels for Heating & Chilled water systems sizes

More information

1. Expansion Vessels. We reserve the right to change designs and technical specifications of our products.

1. Expansion Vessels. We reserve the right to change designs and technical specifications of our products. . Expansion Vessels Flamco produces a comprehensive range of diaphragm expansion vessels. oth the steel vessel and the diaphragm are of the highest quality. They are compliant with all prevailing European

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

264 Product overview 2018 Export We reserve the right to change designs and technical specifications of our products. T-plus Brass.

264 Product overview 2018 Export We reserve the right to change designs and technical specifications of our products. T-plus Brass. T-plus T-plus + The T-plus is an ideal product for the expansion, conversion or overhaul of an existing system. No longer is it necessary to isolate, drain, de-pressurise or freeze a pipe when an extra

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Venting Range and Air/Dirt. Separators

Venting Range and Air/Dirt. Separators Venting Range and ir/irt Separators Separators Venting Range and ir/irt + Systems in which the water is properly deaerated and free of contamination are more efficient, produce less noise and have a longer

More information

10. Universal Clips. 254 Product overview 2013 We reserve the right to change designs and technical specifications of our products.

10. Universal Clips. 254 Product overview 2013 We reserve the right to change designs and technical specifications of our products. 10. Universal lips Whether you need ceiling, wall or floor mounted clips, Flamco has the solution. We offer a wide range of universal mounting clips with a variety of closures, connections and finishes.

More information

SINUS VERTEILER PRODUCT GUIDE

SINUS VERTEILER PRODUCT GUIDE SINUS VERTEILER PRODUCT GUIDE 2017/18 heating heating & cooling & cooling systems systems 1 CUSTOMER CARE EXPORTS The product configurator Stefan Engberding Head of Exports Phone: +49 (0) 2557 / 93 93-62

More information

Modulating Water Valves and Bulb Wells

Modulating Water Valves and Bulb Wells Modulating Water Valves and ulb Wells PPLITION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature

More information

548 hydraulic separator

548 hydraulic separator hydraulic separator 120 C 120 105 C 105 120 Serie 548 120 C 105 C 105 548 imensions C B Function The ltecnic 548 hydraulic separator combines several different components, each of which performs a specific

More information

Components for central heating

Components for central heating 01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling

More information

Mild Steel Dosing Pots

Mild Steel Dosing Pots Mild Steel Dosing Pots Data Sheet Features Introduction Materials of Construction Most heating and chilled water systems require chemical dosing and the BOSS range of Dosing Pots provides a controlled

More information

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY

More information

three-way mixing valve

three-way mixing valve three-way mixing valve with or without presetting, for heating and cooling systems. Pressurisation & Water Quality alancing & Control Thermostatic Control engineering avantage Three-way mixing valve, with

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 23 22 13 STEAM AND CONDENSATE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

KEY FEATURES. Product Overview. Product Line Drawing

KEY FEATURES. Product Overview. Product Line Drawing Main Valves Options Model 106-C 106-PG-C Globe KEY FETURES Solves high pressure drop problems Controls variable flows & vibration Significantly reduces noise Self-contained actuators not required Customizable

More information

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications 28237 www.caleffi.com Circulation units for solar thermal systems Copyright 204 Caleffi 278-279 series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Important Product range Technical specifications

More information

P. R2...P. Two. have. become. Range of Pressure-Independent Control Valves. one

P. R2...P. Two. have. become. Range of Pressure-Independent Control Valves. one P. R2...P Two have become Range of Pressure-Independent Control alves one The pressure-independent control valve R2 P sets new standards The challenge Energy savings with maximum convenience and low installation

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

Flow-compensated temperature controller AVTQ DN 15

Flow-compensated temperature controller AVTQ DN 15 Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers

More information

Valves & Flow Control Components Valves & Flow Control Components

Valves & Flow Control Components Valves & Flow Control Components Section 4 Valves & Flow ontrol omponents Valves & Flow ontrol omponents... 106 SJ-200 Low-Profile utterfly Valve... 107 SJ-300N utterfly Valve... 108 SJ-300F utterfly Valve (for Fire Protection)... 110

More information

AUTOMATIC AIR VALVES For potable water

AUTOMATIC AIR VALVES For potable water AUTOMATIC AIR VALVES For potable water Page N Air release valve Page N Air release valve avent Page N Air release valve DN 0 / DN 0, DN 150 / DN 00 Page N /1 Page N5 Combined air release valve Page N 5/1

More information

HAWLE-AIR RELEASE VALVES

HAWLE-AIR RELEASE VALVES HAWLE-AIR RELEASE VALVES HAWLE-AIR RELEASE VALVES Contents: Dimensions of Air Release Valve Page 2 Why use Air Release Valves? Page 3 Application: Potable water Air Release Valves, DN 1" - DN 2" Page 4

More information

HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards

More information

HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet HS10S-FA Water station Product specification sheet Range of Application Medium Drinking water Inlet pressure Max. 16 bar Outlet pressure 1.5-6.5 bar Installation position Horizontal with filter bowl downwards

More information

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

PRESSURIZED STEEL BOILER WITH REVERSED FLAME smoke pipes PRESSURIZED STEEL BOILER WITH REVERSED FLAME OUTPUT RANGE from 340 to 7000 WORKING TEMPERATURE minimum return temperature 55 OPERATION WITH gas or oil fired jet burners MODELS 340 420 510 630

More information

Section - B. Air vents

Section - B. Air vents Section - Air vents AIR VENTS EXAMPLE OF APPLICATION 2 1 2 4 5 2 3 3 4 6 1 Automatic air vent valves. 2 Manual air vent valves. 3 Air vent valves with adjustable discharge nozzle. 4 Air vents with float..

More information

Valve Selection. 1. Function and service considerations

Valve Selection. 1. Function and service considerations 1. Function and service considerations Valve Selection Selection Valves serve the purpose of controlling the fluids in building services piping. Valves are produced in a variety of design types and materials.

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C) Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35

More information

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves. Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

DEP7 SG Iron Excess Pressure Valve

DEP7 SG Iron Excess Pressure Valve Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

DA 50. Differential pressure controllers Adjustable set-point

DA 50. Differential pressure controllers Adjustable set-point DA 50 Differential pressure controllers Adjustable set-point IMI TA / Differential pressure controllers / DA 50 DA 50 These differential pressure controllers for heating and cooling systems are particularly

More information

Grey cast iron SG iron Cast steel/ Forged steel High temperature steel Stainless steel Fig. 631 Page 2

Grey cast iron SG iron Cast steel/ Forged steel High temperature steel Stainless steel Fig. 631 Page 2 CONA S Ball float steam trap Ball float steam trap Ball float steam trap PN16 / PN40 - with flanges (Fig. 631...1) - with screwed sockets (Fig. 631...2) - with socket weld ends (Fig. 631...3) - with butt

More information

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES TECHNICAL AND INSTALLATION DOCUMENTATION STOKVIS ENERGY SYSTEMS UNIT 34 CENTRAL PARK ESTATE 34 CENTRAL PARK ESTATE WEST

More information

ACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM

ACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM alancing valve with flow meter 1 series REDITED ISO 9001 FM 1 LEFFI 0119/1 G replaces dp 0119/08 G Function The balancing valve is a hydraulic device that accurately regulates the flow rate of heating

More information

197C. Valve Group. Series Farris Engineering Pressure Relief Valves

197C. Valve Group. Series Farris Engineering Pressure Relief Valves 97 Valve Group Series 700 Farris Engineering Pressure Relief Valves Numbering System Selecting and specifying Farris pressure relief valves is simple using the numbering system that follows. Each digit

More information

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB ydraulic separator-manifold SPO 559 series RT SO 01 M 21654 01084/16 replaces dp 01084/13 unction The SPO, a device which combines the functions of hydraulic separator and distribution manifold, is used

More information

British Standard institute-bs Valve Standards

British Standard institute-bs Valve Standards BS 341-1:1991 Transportable gas container valves. Specification for industrial valves for working pressures up to and including 300 bar (REPLACED by BS EN 14189:2003), BS 341-3:2002), BS EN 849:1997),

More information

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function Mixing valves and actuators 610-611 - 612-63 series RIT ISO 01 M 214 LI 01169/17 replaces dp 01169/09 unction The mixing valves allow the centralisation heating system to be regulated by mixing the boiler

More information

PHP-C Pressureless Expansion System Overview Description: The PHP-C balanced pressure expansion equipment is sized according to the total system volume and the boiler or chiller load. The PHP-C vessel

More information

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Pre-Fabricated Flushing Bypass Assembly for Plant Applications Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and operation of plant devices. Flow

More information

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components 7EN www.caleffi.com Circulation units for solar thermal systems Copyright Caleffi 7HE - 79HE series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Product range Technical specifications Characteristic

More information

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA Motorized ball valves with -wire control 644-644 series SO 900 M 64 SO 900 No. 000 0/ N Replaces 0/07 N unction Zone valves are used to automatically shut-off the flow, redirect or modulate hot and chilled

More information

Automatic Control Valves WATTS EU 100 Series

Automatic Control Valves WATTS EU 100 Series utomatic ontrol Valves WTTS U Series The Watts Industries range of automatic control valves consist of a hydraulically operated valve, which is controlled by a pilot circuit. The main valve (U ) is the

More information

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation,

More information

Taps, Valves & Components. Section 1

Taps, Valves & Components. Section 1 Taps, Valves & Components Section 1 taps, valves & components index Index 1 SECTION PAGE sink taps 1.1-1.4 sink taps & spares 1.5 basin taps 1.6 general purpose taps & valves 1.7 flexible connectors, angle

More information

DESCRIPTION 9.4 G 3/4"M

DESCRIPTION 9.4 G 3/4M DESCRIPTION Six-way ballvalve for HVAC 4 pipes applications to automatically carry out the winter-summer change-over or, potentially, to manage radiant ceilings, fan coils and chilled beams. DIMENSIONS

More information

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection Temperature Model W91 (No Indicating Dial) W94 (Temperature Indicating Dial) Service Water, Steam, Other Liquids Sizes 1/2 4 onnections Threaded, Union Ends, 125# FLG 250# FLG (optional) ody Material 1/2

More information

Pressure independent balancing and control valve AB-QM DN

Pressure independent balancing and control valve AB-QM DN Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications

More information

CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range

CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range iverter and isolation valves for panel radiators 00, 0, 02, 0 series RIT LI 006/2 N ISO 900 M 2654 ISO 900 No. 000 unction aleffi 0 series valves are installed on panel style radiators. They are connected

More information

3-port seat valves PN6 with flanged connection

3-port seat valves PN6 with flanged connection 4 410 cvatix 3-port seat valves PN6 with flanged connection VXF21.. Grey cast iron EN-GJL-250 valve body DN 25...100 k vs 1.9...160 m 3 /h Can be equipped with SQX.. electromotoric or SKD..-, SK..- and

More information

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers Engineering Data Manual Water Cooled Water Chillers Cooling Only Version () Condenserless Version () Heat Pump Version () Models 02 to 35 8 to 136 9 to 164 N IRWELL GROUP MPNY Specifications General The

More information

VIESMANN VITODENS 222-F

VIESMANN VITODENS 222-F VISMNN VITONS 222- atasheet or part no. and prices: see pricelist VITONS 222- Type 2T as condensing storage combi boiler, 3.2 to 35. kw for natural gas and LP VITONS 222- Type 2S as condensing storage

More information

SPIROVENT MICROBUBBLE DEAERATORS AND DIRT SEPARATORS

SPIROVENT MICROBUBBLE DEAERATORS AND DIRT SEPARATORS SPIROVENT MICROBUBBLE DEAERATORS AND DIRT SEPARATORS S P I R O V E N T A I R & D I R T Air - and dirt - free system water through a single unit 1 100 mm N.B. Weld end 100 mm N.B. Flanged 100 mm N.B. Demountable

More information

SELF-CLEANING FILTER

SELF-CLEANING FILTER SELF-CLEANING FILTER CT0126.0_00 UK November 2008 PRODUCTION RANGE Connections Standard Mesh [μm] Size Code Kv [m³/h] THREADED FF UNI-EN-ISO 228 100 3/8 126.03.10 1,80 1/2 126.04.10 3,10 3/4 126.05.10

More information

Gauges, Sight Glasses and Vacuum Breakers

Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges Pressure gauges Pressure gauges should be installed in at least the following situations: Upstream of a pressure

More information

CONA Further components / Accessories

CONA Further components / Accessories CONA Further components / Accessories Liquid drainer PN16 / PN40 - with flanges (Fig. 665...1) - with screwed sockets (Fig. 665...2) - with socket weld ends (Fig. 665...3) - with butt weld ends (Fig. 665...4)

More information

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB. Composite manifolds specifically designed for radiant panel systems 670 series FM 165 00 CALEFFI 0116/18 GB replaces dp 0116/11 GB Function Composite manifolds are used to control and distribute the medium

More information

Zeparo G-Force. Automatic air vents and separators Microbubble, dirt and magnetite separator with Cyclonic technology

Zeparo G-Force. Automatic air vents and separators Microbubble, dirt and magnetite separator with Cyclonic technology Zeparo G-Force Automatic air vents and separators Microbubble, dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo G-Force Zeparo G-Force

More information

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB. Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise

More information

Electronic Temperature Control & Bulb Well Assembly (AC)

Electronic Temperature Control & Bulb Well Assembly (AC) Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed

More information

IC3A, IC3D, IC4A and IC4D ISO Spirax-Monnier International Ultraclean Compressed Air Filters

IC3A, IC3D, IC4A and IC4D ISO Spirax-Monnier International Ultraclean Compressed Air Filters Page 1 of 5 ert. No. LRQ 0963008 Manual rain TI-P501-01 H Issue 5 I3, I3, I4 and I4 ISO 9001 Spirax-Monnier International Ultraclean ompressed ir Filters uto rain International Symbol escription The Spirax-Monnier

More information

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Data sheet Flow controller with integrated control valve (PN 16) AHQM return and flow mounting Description DN 15-32 DN 40, 50 DN 50-100 DN 125 DN 150 DN 200, 250 AHQM is a self-acting flow controller with

More information

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S 16/26 SRIS O M P T & S T N R M O U L R I R P R P R T I O N S Y S T M S WILKRSON FILTRS, RGULTORS N LUBRITORS R26 Regulator F26 Filter L26 Lubricator M16 oalescing Filter B6 Filter/Regulator w/ Optional

More information

ABS submersible sewage pump AFP

ABS submersible sewage pump AFP BS submersible sewage pump FP - Robust, reliable submersible pumps from. to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance

More information

Model Model 815

Model Model 815 Model 600004 Model 600204 Model 85387 Model 600104 Model 815 ir line products and accessories ir couplers and nipples............................... 196 low guns, tire inflators and siphon sprayers.............

More information

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY SECTION 23 21 16 - HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Air

More information

Product range Solex Technical data and dimensioning. 5 Years

Product range Solex Technical data and dimensioning. 5 Years Qualität made in Germany Product range Solex Technical data and dimensioning Quality made in Germany 5 Years Handwerkergarantie m anufacturer s warranty Product range Solex Dimensioning High-Flow system

More information

TRUNNION MOUNTED METAL SEATED BALL VALVES

TRUNNION MOUNTED METAL SEATED BALL VALVES TRUNNION MOUNTED METAL SEATED BALL VALVES HIGH PERFORMANCE BALL VALVES FOR SEVERE SERVICES PROCESS VALVES STANDARD FEATURES FOR SIDE ENTRY & BOTTOM ENTRY DESIGN 1. Trunnion Mounted The ball is trunnion

More information

Type overview. R B2 en-gb subject to changes 1

Type overview.  R B2 en-gb subject to changes 1 Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of

More information

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES 19 CONTENTS ROTARY MOTORIZED VALVES INTRODUCTION AND SELECTION GUIDES Series VRG130 DN 15 50, Kvs 0.4 40, PN10 33 34 35 Series VRG140 DN 15 50, Kvs.5 40, PN10 CHANGE-OVER/DIVERTING

More information

CALEFFI. HydroMixer direct distribution unit for heating systems. 165 series 01237/13 NA. Function

CALEFFI. HydroMixer direct distribution unit for heating systems. 165 series 01237/13 NA. Function HydroMixer direct distribution unit for heating systems 6 series REDITED LEI ISO 900 M 6 ISO 900 No. 000 07/ N unction The 6 series HydroMixer TM provides high temperature flow direct to secondary heating

More information

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.

More information

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators. Data sheet Flow and temperature controller with / without integrated control valve (PN 25) AVQT - flow and temperature controller AVQMT - flow and temperature controller with integrated control valve Description

More information

3-port seat valves, external thread, PN16

3-port seat valves, external thread, PN16 4 464 3-port seat valves, external thread, PN6 VXG44.. ronze CC49K (Rg5) valve body DN 5..DN 40 k vs 0.25..25 m 3 /h Flat sealing connections with external thread G to ISO 228- Sets of ALG..3 screwed fittings

More information

Selection Guide. Vx-7000 & Vx-9000 Series Mx4x-6xxx & Mx4x-7xxx Series. Globe Valve Assemblies. Actuator/Linkage Assemblies

Selection Guide. Vx-7000 & Vx-9000 Series Mx4x-6xxx & Mx4x-7xxx Series. Globe Valve Assemblies. Actuator/Linkage Assemblies Vx-7000 & Vx-9000 Series Mxx-6xxx & Mxx-7xxx Series Selection Guide Linked Globe Valve ssemblies ctuator/linkage ssemblies with DuraDrive ctuators Globe Valve ssemblies The V, VF, and VS-7000 and -9000

More information

Accessories. UP timer. Timer control. Approvals. UP Series

Accessories. UP timer. Timer control. Approvals. UP Series UP timer Specifications (previous/current) Type: 24 Hr. 3-position On/Timer/Off 15-minute interval Size: 3.77 x 2.85 x 1.25" Supply voltage: 120 VC Power consumption: 1 V Switch rating: SPT Resistive:

More information

Safety Stations with Eyewash

Safety Stations with Eyewash Safety Stations with yewash F G1942 Safety Station with yewash, Freeze and Scald Protection Valves pplication: ombination eyewash and shower safety station. Unit is furnished with temperature-actuated

More information

SELECTION. Easily Selectable Easily Serviceable. Interchangeability as easy as 1-2-3

SELECTION. Easily Selectable Easily Serviceable. Interchangeability as easy as 1-2-3 SELETION Terminal Unit Zone Valve 1 Select your valve body Female Thread Solder ouble Union 2 Select your cartridge type hoice of V Hot and hilled Water 50% Glycol Low Pressure Steam Pressure alanced Male

More information

Pressure Reducing Valve Type 2114/2415

Pressure Reducing Valve Type 2114/2415 Pressure Reducing Valve Type 2114/2415 Fig. 1 Type 2114/2415 1. Design and principle of operation The Type 2114/2415 Pressure Reducing Valve consists of the Type 2114 Valve and the Type 2415 Actuator.

More information

Temperature Regulators

Temperature Regulators Temperature Regulators DESIGN & OPERATION DIAL THERMOMETER (Model 91400 only) BELLOWS OVERRANGE PROTECTION SPRING CAPILLARY TUBING CONNECTION SENSING BULB RANGE ADJUSTMENT SPRING CAP ADJUSTMENT SCREW BUSHING

More information

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES 5 6 ESBE ROTARY VALVES AND ACTUATORS regulate the heating comfort of millions of households. Our offer is a wide range of rotary valves in a number of different designs for the

More information

Installation & Technical Guide. Domestic & Commercial.

Installation & Technical Guide. Domestic & Commercial. Installation & Technical Guide Domestic & Commercial www.challisbooster.com www.challisboosterplus.com Installation and Technical Guide Domestic and Commercial Challis Water Controls Europower House, Lower

More information

DRV7 and DRV7G SG Iron Pressure Reducing Valves

DRV7 and DRV7G SG Iron Pressure Reducing Valves Local regulations may restrict the use of this product to below the conditions quoted. n the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Elbow ball check valves PRODUCT CATALOG

Elbow ball check valves PRODUCT CATALOG Elbow ball check valves PRODUCT CATAOG Version 01.16 Technical data Range of available diameters: 32 300. Pressure rated to PN 1.6 MPa (all valves are tested to PN 1.0 MPa leak test / PN 1.6 MPa hydrostatic

More information

Two-port and three-port small valves PN16, ANSI Class 250

Two-port and three-port small valves PN16, ANSI Class 250 4 845 Two-port valves (2-ports) VVP45.10-0.25 to VVP45.25-6.3 VVK45... Three-port valves (3-ports) VXP45.10-0.25 to VXP45.25-6.3 VXK45... Three-port valves with T bypass (4-ports) VMP45.10-0.25 to VMP45.25-4

More information

Datasheet. Flamcomat - Pressureless Expansion System

Datasheet. Flamcomat - Pressureless Expansion System Flamcomat - Pressureless Expansion System The Flamcomat balanced pressure expansion equipment is sized according to the total system volume and the boiler / chiller load. The Flamcomat vessel is 80% efficient

More information

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.

More information

Flamco T-Plus. Now with easy to use trigger

Flamco T-Plus. Now with easy to use trigger 9. Flamco T-Plus The T-Plus is an ideal product for the expansion, conversion or overhaul of an existing system. No longer is it necessary to isolate, drain, de-pressurise or freeze a pipe when an extra

More information

Series TD. Type TDL Type TDM. Automatic Recirculation Valve for pump protection

Series TD. Type TDL Type TDM. Automatic Recirculation Valve for pump protection Series TD Type TDL Type TDM Automatic Recirculation Valve for pump protection Series TD The SCHROEDAHL Automatic Recirculation Valve is used for the pump protection of centrifugal pumps Preamble SCHROEDAHL

More information

Pressure reducing valve Pressure reducing valve in straightway form DN

Pressure reducing valve Pressure reducing valve in straightway form DN Pressure reducing valve Pressure reducing valve in straightway form DN 15-150 ARI-PREDU Pressure regulating valve, straight through with diaphragm actuator DMA Actuator with rolling diaphragm Grey cast

More information

Pressure independent balancing and control valve

Pressure independent balancing and control valve Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications

More information

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant

More information

Hollow Cone Nozzles. Gas cooling Sulfur Burning dust control water aerating chemical Production Cooling m e t a l T r e a t i n g w A S H i n g

Hollow Cone Nozzles. Gas cooling Sulfur Burning dust control water aerating chemical Production Cooling m e t a l T r e a t i n g w A S H i n g Hollow one s Gas cooling ulfur urning dust control water aerating chemical Production ooling m e t a l T r e a t i n g w H i n g gas scrubbing brine spraying product degreasing D1 HOO ON NOZZ INTRODUTION

More information

3-port seat valves PN10 with flanged connection

3-port seat valves PN10 with flanged connection 4 420 cvatix 3-port seat valves PN10 with flanged connection VXF31.. Grey cast iron EN-GJL-250 valve body DN 15 150 k vs 2.5 315 m 3 /h Can be equipped with SX..-electromotoric or SKD..-, SK..- and SKC..-

More information

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

Differential Pressure Control Valve

Differential Pressure Control Valve Differential Pressure Control Valve www.ballorex.com 2 Table of contents Chapter Ballorex Delta DHC DN 15-150 1. Safety instructions 4 1.1 Rules/regulations 4 1.2 Intended use 5 1.3 Initial operation 5

More information

Stainless Steel FRLs

Stainless Steel FRLs Stainless steel FRLs Stainless Steel FRLs Units 205 Stainless steel FRLs - PF504 Series - 1/4 Inch Ports PF504 Filter Miniature Features Stainless steel construction handles most corrosive environments

More information

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting Data sheet Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting Description The controller has a control valve with adjustable

More information