RENTING OF CLIMATIC TEST SYSTEMS

Size: px
Start display at page:

Download "RENTING OF CLIMATIC TEST SYSTEMS"

Transcription

1 VTRK 500 (Vötsch climatic test system) Temperature range: C Humidity range: 10-95% rh Dew point range: 5-89 C Test space volume: 500 litres Test space dimensions: W750xD880xH765mm External dimensions: W1060xD1380xH1950mm Electrical connection: 220 V 1/N 50Hz VTRK 1000 (Vötsch climatic test system) Temperature range: C Humidity range: 10-95% rh Dew point range: 5-89 C Test space volume: 1000 litres Test space dimensions: W1250xD640xH1230mm External dimensions: W2360xD960xH1910mm HC 0020 (Vötsch climatic test system) Temperature range: +20/+90 C Humidity range: % rh Dew point range: +10/+88 C Test space volume: 200 litres Test space dimensions: W575xD550xH650mm External dimensions: W830xD1265xH1725mm Electrical connection: 220 V 1/N 50Hz

2 HC 4030 (Vötsch climatic test system) Humidity range: % rh Dew point range: -10/+89 C Test space volume: 300 litre Test space dimensions: W650xD645xH745mm External dimensions: W935xD1410xH1780mm VC 4034 (Vötsch climatic test system) Temperature range: -40/+180 C Humidity range: % rh Dew point range: -3/+94 C Test space volume: 335 litre Test space dimensions: W580xD765xH750mm External dimensions: W865xD1595xH1780mm Electrical connection: 400V 3/N 50 Hz VLK 04/150 (Vötsch climatic test system) Dew point range: +5/+89 C Test space volume: 150 litres Test space dimensions: W540xD515xH545mm External dimensions: W850xD1380xH1950mm

3 VLK 04/300 (Vötsch climatic test system) Dew point range: +5/+89 C Test space volume: 300 litres Test space dimensions: W600xD750xH670mm External dimensions: W850xD1380xH1950mm WK 1-340/40 (Weiss climatic test system) Temperature range: -40/+180 C Dew point range: 4-94 C Test space volume: 335 litres Test space dimensions: W580xD765xH750mm External dimensions: W870xD1600xH1780mm Electrical connection: 400V 3/N 50Hz Humidity measurement: PT 100, psychrometer VMT 07/35 (Vötsch temperature system) Temperature range: -70/+180 C Test space volume: 34 litres Test space dimensions: W320xD270xH400mm External dimensions: W920xD660xH600mm

4 VMT 08/140 (Vötsch temperature system) Temperature range: -80/+150 C Test space volume: 140 litres Test space dimensions: W560xD510xH500mm External dimensions: W850xD1045xH1240mm Electrical connections: 380 V 3/N 50Hz Control: Pt 100, electronic temperature controller VEM 03/400 (Vötsch temperature system) Temperature range: -30/+60 C Test space volume: 400 litres Test space dimensions: W620xD460xH1400mm External dimensions: W770xD740xH1900mm Control: electronic temperature controller VMT 07/35 (Vötsch temperature system) Temperature range: -70/+180 C Test space volume: 34 litre Test space dimensions: W320xD270xH400mm External dimensions: W920xD660xH600mm

5 VMS 2/120/220 (Vötsch shock test, 2 chambers) Temperature range: -80/+220 C Test space volume: 122 litres Test space dimensions: W470xD650xH400mm External dimensions: W880xD1850xH1950mm Electrical connections: 380 V 3/N 50Hz Air flow: horizontal Temperature protection: Pt100, adjustable SC 450 (Weiss salt spray test cabinet) Temperature range: 5K above ambient temperature to +55 C Test space volume: 480 liters Test space dimensions: L850xD570xH1190mm (with hood) External dimensions: L1930xD800xH1370mm Air throughput: 5-8 Nm³/h Compressed air: min. 2 bar / max. 10 bar Control: microprocessor control unit Brine reservoir: 180 litres

CLIMATE. Climate and temperature chambers.

CLIMATE. Climate and temperature chambers. Climate and temperature chambers. The Environmental Competence Centre has a number of climate chambers at its disposal to carry out low and high temperature tests, as well as a number of combined climate

More information

Salt Spray Chamber HKT 1000

Salt Spray Chamber HKT 1000 Salt Spray Chamber HKT 1000 Corrosion testing system to carry out atmospheric corrosion tests according to the following test specification: DIN EN ISO 9227 (DIN 50 021) NSS, AASS, CASS test DIN EN 60068-2-11

More information

TEST REPORT CONCERNING THE COMPLIANCE OF A VOTING MACHINE FOR USE AT ELECTIONS IN IRELAND, BRAND NEDAP, MODEL P.R.U

TEST REPORT CONCERNING THE COMPLIANCE OF A VOTING MACHINE FOR USE AT ELECTIONS IN IRELAND, BRAND NEDAP, MODEL P.R.U Testing and certification of electric, electronic and radio equipment/installations including telecommunication systems TEST REPORT CONCERNING THE COMPLIANCE OF A VOTING MACHINE FOR USE AT ELECTIONS IN

More information

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371 Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371 Specification/Model SS600e CASS/AASS SS1000e CASS/AASS SS1300e CASS/AASS SS3000e CASS/AASS Chamber Temperature Range Ambient + 9

More information

GENERAL PURPOSE INCUBATOR

GENERAL PURPOSE INCUBATOR PRODUCT CATALOG www.biolabscientific.com Biolab Scientific offers a range of high quality, efficient and reliable general purpose incubators that provide superior degree of temperature uniformity. Equipped

More information

CALIBRATION CERTIFICATES

CALIBRATION CERTIFICATES CALIBRATION CERTIFICATES Calibration certificates - temperature and pressure - sensor deviation reduced to zero The patented ALMEMO measuring technology from Ahlborn has proved itself many times over in

More information

3 Pin Schuko Converter Plug Technical Data & Fitting Instructions

3 Pin Schuko Converter Plug Technical Data & Fitting Instructions 3 Pin Schuko Converter Plug Technical Data & Fitting Instructions Description The 3 Pin Schuko Converter Plug (SCP3) is an adapter that converts the European IEC 83:1975 Standard C 2b, C4, C5, and C6 plug

More information

Cyclic Corrosion Test CORR Series

Cyclic Corrosion Test CORR Series Cyclic Corrosion Test CORR Series CCT 1300 CORR image merely illustrative Specifications/Model CCT 1300 CORR CCT 3000 CORR CCT 5000 CORR - Mode: SALT SPRAY / SALT FOG - Mode: WATER CONDENSATION HUMIDITY

More information

Cyclic Corrosion Chamber C.C.T AUTO Series

Cyclic Corrosion Chamber C.C.T AUTO Series Cyclic Corrosion Chamber C.C.T AUTO Series CCT 5000 AUTO image merely illustrative Cooling system image merely illustrative Specifications/ Models CCT 1300 AUTO CCT 3000 AUTO CCT 5000 AUTO Allows 7 different

More information

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc 13.10.2017-1 - CTS - Climatic Test Cabinet Type CP+10/1200 C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English

More information

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai Last Amended on - Page 1 of 10 I. EMI / EMC TESTS 1. IT Products / Household / Industrial / Medical / Network Telecommunications Equipment Radiated Emission Test (RE) CISPR11:2010 BSEN 55011:2010 CISPR22:2008

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

MICRO SWITCH ESS SERIES

MICRO SWITCH ESS SERIES MICRO SWITCH ESS SERIES FEATURES Small compact size suitable for electric equipment appliances and P.C.B. layout 2-piece spring mechanism design offering durable acute operation and long life Heavy/Light

More information

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8 Electrical Control s Series EX4, EX5, EX6, EX7 & EX8 Features Multifunction as expansion valve, hot gas bypass, suction gas throttling, head pressure, liquid level actuator etc. Fully hermetic design (no

More information

REMOVAL AND INSTALLATION

REMOVAL AND INSTALLATION 501-12-1 Instrument Panel and Console 501-12-1 REMOVAL AND INSTALLATION Instrument Panel Removal CAUTION: Electronic modules are sensitive to static electrical charges. If exposed to these charges, damage

More information

Digital refrigerators lt

Digital refrigerators lt The models detailed on this sheet are 600 liter fan assisted refrigerators that offer excellent standards in terms of performance and efficiency. These models come in 0 C and -2 C versions with a choice

More information

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc. Technical Data, High Power 2-way* Electrical Data Operating Voltage Operating Current Contact Resistance Voltage Proof Insulation Resistance Mechanical Data 48 VDC* see derating curve 2 mω max. 1000 VAC,

More information

Universal test stand for pneumatic components >PP200STA<

Universal test stand for pneumatic components >PP200STA< Universal test stand for pneumatic components >PP200STA< Schematic diagram: PNEUMATIC This shown construction has been designed and realised for SR Technics Developed

More information

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application 2-3.1 ATC 510/520/525 for wall-mounting Application The ATC 510/5205/525 is a modern microprocessor-based (PID) control device featuring easy handling and a digital display. The clear design of the operator

More information

Electrical Control Valves

Electrical Control Valves 172 Electrical Control Valves Electrical Control Valves Electrical Control Valve Technology Thermostatic expansion valves and mechanical regulator valves have been used in the refrigeration and air conditioning

More information

ENVIRONMENTAL TESTING

ENVIRONMENTAL TESTING ENVIRONMENTAL TESTING Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock Page 6 Corrosive

More information

Operators Manual. Microprocessor Controlled Water Baths /98

Operators Manual. Microprocessor Controlled Water Baths /98 Operators Manual Microprocessor Controlled Water Baths 110-012 7/98 Table Of Contents Section 1 - General Information 1.1 Warranty 1.2 Unpacking 1.3 Package Contents 1.4 Description Section 2 - Set Up

More information

2006 Ford Pickup F350 Super Duty

2006 Ford Pickup F350 Super Duty Fig. 100: Identifying Evaporator Core Housing Components Removal All vehicles 1. Remove the suction accumulator. For additional information, refer to SUCTION ACCUMULATOR. 2. Remove the RH battery. For

More information

SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR

SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR 148 RATINGS AND SPECIFICATIONS TIME RATING Continuous AMBIENT TEMPERATURE 0 to 40 C INSULATION CLASS F AMBIENT HUMIDITY 20 to 80% RH (non condensing) POLES 14 THERMAL PROTECTION PT 1000 INSULATION SYSTEM

More information

General Purpose Relay

General Purpose Relay General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)

More information

MAKING MODERN LIVING POSSIBLE. Datasheets. Maneurop Reciprocating compressors MT / MTZ / MPZ / NTZ FRCC.UD

MAKING MODERN LIVING POSSIBLE. Datasheets. Maneurop Reciprocating compressors MT / MTZ / MPZ / NTZ FRCC.UD MAKING MODERN LIVING POSSIBLE Datasheets Maneurop Reciprocating compressors MT / MTZ / MPZ / NTZ FRCC.UD.130409.160126 www.danfoss.com/odsg Datasheet, technical data Maneurop reciprocating compressor,

More information

Broetje-Automation Company Standard Coating

Broetje-Automation Company Standard Coating Broetje-Automation Company Standard Table of Contents Scope and Objective... 2 1 Standards and Corrosion Protection... 2 1.1 Standards... 2 1.2 Corrosion Resistance... 2 2 Surface Preparation... 3 2.1

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION 1. SCOPE This specification covers the T-FLASH MEMORYCARD SOCKET series. 2. PRODUCT NAME AND PART NUMBER Product Name Part Number Assembly 49225-811 Embossed Package 49225-811 3. RATINGS Item Standard

More information

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to THWD-5 Relative Humidity Temperature Meter Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com THWD-5 Relative Humidity Temperature Meter English Users Manual THWD5_Rev001

More information

TESTS, MEASUREMENTS, ANALYSIS VIBRATION AND PRESSURE TESTS ENVIRONMENTAL AND CORROSION TESTS

TESTS, MEASUREMENTS, ANALYSIS VIBRATION AND PRESSURE TESTS ENVIRONMENTAL AND CORROSION TESTS , MEASUREMENTS, ANALYSIS VIBRATION AND PRESSURE ENVIRONMENTAL AND CORROSION VIBRATION AND ENVIRONMENTAL MECHANICAL RESISTANCE VZLU TEST, a.s. provides a wide range of development, qualification and serial

More information

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS Portable Industrial Chilled Mirror Hygrometer Fundamental drift free humidity measurement Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System for fast measurement

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB RE 18377 Edition: 11.2017 Size 2 Series B Maximum working pressure 420 bar

More information

Universal test stand for pneumatic components >PP200STA<

Universal test stand for pneumatic components >PP200STA< Universal test stand for pneumatic components >PP200STA< Schematic diagram: PNEUMATIC This shown construction has been designed and realised for SR Technics Developed

More information

Short manual testo 410-2

Short manual testo 410-2 Short manual testo 410-2 11 Short manual testo 410-2 Protection cap: Park position Impeller Humidity/temperature sensor Display Control keys Battery compartment (on rear) it es fr en de Basic settings

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK High Post Contact: Enquiries +44 (0)1722 411611 Salisbury Tel: +44 (0)1722 428739 Wiltshire Fax: +44 (0)1722 428794 SP4 6AS E-Mail: ian.callender@chemringcm.com

More information

SafeLogic compact. Input/output module (8 inputs, 4 outputs) SLC-3-XTDS84302

SafeLogic compact. Input/output module (8 inputs, 4 outputs) SLC-3-XTDS84302 Input/output module (8 inputs, 4 outputs) 2 Bosch Rexroth AG Electric Drives and Controls Input/output module (8 inputs, 4 outputs) Documentation 8 SIL3 safety inputs, 4 standard outputs, 2 configurable

More information

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory

More information

TIF VA500A DIGITAL HVAC ANALYZER

TIF VA500A DIGITAL HVAC ANALYZER 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com TIF VA500A DIGITAL HVAC ANALYZER Owner s Manual TABLE of CONTENTS 1. INTRODUCTION...........................4 2. FEATURES...............................5

More information

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 4118 N/ The engineer's choice The engineer's choice 4118 N/12-190 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Operating Data - Electrical

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

Technical data sheet. Technical data. Safety notes

Technical data sheet. Technical data. Safety notes echnical data sheet NM24P Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8 Nm Nominal voltage

More information

Technical Data, 4-way. Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc. ISO 15170) Materials List

Technical Data, 4-way. Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc. ISO 15170) Materials List Technical Data, 4-way Cannon APD / ISO 15170 Connectors APD 4-way connectors are the original DIN72585 (now ISO 15170) versions using a 2,5 mm contact system. Designed for automotive applications they

More information

SC0715BL STANDARD BUZZER

SC0715BL STANDARD BUZZER Pagina 1 van 6 The standard series are based on the highest piezo technology and are considered to be the most robust series for industrial applications. The standard buzzers use a bent edge membrane,

More information

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines GASBOARD 5020 is an analyser for the control of exhaust gases from gasoline or LPG engines; it integrates non dispersive

More information

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791) Installation Guide VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791) VICPA222 Technical Data Power 24 Vac ±20%, 50/60 Hz Power consumption 8 VA (running)

More information

Product Data Sheet 3214 J/2H3F-191

Product Data Sheet 3214 J/2H3F-191 The engineer's choice 3214 J/2H3F-191 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical

More information

Industrial plug-in connectors HEAVYCON EVO. efficient at a twist of the wrist

Industrial plug-in connectors HEAVYCON EVO. efficient at a twist of the wrist Industrial plug-in connectors HEAVYCON EVO efficient at a twist of the wrist For more efficiency in your system HEAVYCON EVO Heavy-duty plug-in connectors are established on the market and are used in

More information

STABILITY TESTING CLIMATIC CHAMBER

STABILITY TESTING CLIMATIC CHAMBER STABILITY TESTING CLIMATIC CHAMBER (+5 C +80 C) (10% Rh 90% Rh) STKK-190 DF STKK-340 DF STKK-500 DF STKK-1000 DF STKK-1700 DF Perfect tool for stability testing in pharmaceutical Industry Following ICH

More information

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40... echnical data sheet SM24P-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..2 m 2 orque 8 Nm Nominal

More information

AUTOMOTIVE VEHICLES AIR BRAKE SYSTEMS PERFORMANCE REQUIREMENTS FOR DRAIN VALVES

AUTOMOTIVE VEHICLES AIR BRAKE SYSTEMS PERFORMANCE REQUIREMENTS FOR DRAIN VALVES For BIS use only Draft Indian Standard AUTOMOTIVE VEHICLES AIR BRAKE SYSTEMS PERFORMANCE REQUIREMENTS FOR DRAIN VALVES Not to be reproduced or used as a Standard without permission from BIS Foreword (Formal

More information

Kesternich - Series KEQ

Kesternich - Series KEQ Kesternich - Series KEQ The chambers of this series create a totally controlled acid humid environment. The samples are exposed to acid and saturated simulating the real conditions as the gases emitted

More information

Technical Data Sheet VENUS FLA SCM

Technical Data Sheet VENUS FLA SCM VENUS FLA SCM VENUS Material Outside Material Component Material Colour Flammability Back panel ASA UV stabilized, halogen free grey, RAL 7040 UL94-HB Cover ASA UV stabilized, halogen free grey, RAL 7040

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

Catalog / 2016 North American Edition

Catalog / 2016 North American Edition Catalog 34 2015 / 2016 North American Edition Air throughput 62 106 cfm (105 180 m³/h) Air throughput 135 323 cfm (230 550 m³/h) TopTherm Filter Fans 3239.100 3239.110 3239.124 3240.100 3240.110 3240.124

More information

High Current Inductors / PIL Series

High Current Inductors / PIL Series .Features: 1. Surface mount inductor with high current rating. 2. Low resistance to keep power loss minimum..applications: Excellent for power line DC-DC conversion applications used in hard disk, notebook

More information

AVM 105, 115: Valve actuator

AVM 105, 115: Valve actuator Product data sheet 6.1 51.361 VM 105, 115: Valve actuator How energy efficiency is improved Torque-dependent cut-off facility for efficient usage of energy Features ctivation of 2-way and 3-way valves

More information

1. With the vehicle in NEUTRAL, position it on a hoist. For additional information, refer to Section

1. With the vehicle in NEUTRAL, position it on a hoist. For additional information, refer to Section SECTION 303-01C: Engine 5.4L (4V) 2009 Mustang Workshop Manual REMOVAL Procedure revision date: 07/25/2008 Engine Special Tool(s) Heavy Duty Floor Crane 014-00071 or equivalent Lifting Bracket, Engine

More information

Chain lubrication unit WS-E

Chain lubrication unit WS-E Product description Chain lubrication unit WS-E APPLICATION The central lubrication system WS- E is used for automatic and metered lubrication of chains, joints, rollers, hinges, etc. This system is also

More information

24V TO 13.5V FIXED OUTPUT VOLTAGE CONVERTER

24V TO 13.5V FIXED OUTPUT VOLTAGE CONVERTER 3092 PRODUCTION RELESE B 3257 DDED TOLERNCES 52152 24V TO 13.5V FIXED OUTPUT VOLTGE CONVERTER PROPRIETRY THIS DRWING IS THE PROPERTY OF SURE POWER INC. and shall not be copied, reproduced, lent, or disposed

More information

Operating Manual. Operating Manual HYBRIDIZATION INCUBATOR. combi-h12 combi-d24 combi-v12 combi-sv12 combi-sv120

Operating Manual. Operating Manual HYBRIDIZATION INCUBATOR. combi-h12 combi-d24 combi-v12 combi-sv12 combi-sv120 Operating Manual Operating Manual. PRODUCTS DESCRIPTION. USER CONSIDERATION. USER OPERATION. ACCESSORIES. MAINTENANCE AND CLEANING. FAULTY RUNNING. WARRANTY combi-h combi-d combi-v combi-sv combi-sv0 YANG-CHUN

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature echnical data sheet SR24P-R Robustline rotary actuator for butterfly valves and rotary valves in Retrofit applications orque 18 Nm Nominal voltage AC/DC 24 V Control: Open-close or 3-point Optimum protection

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Holder of certificate: Amphenol-Tuchel

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON.

HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON. C H I L L E D M I R R O R HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON. 1 2 3 4 5 6 7 8 9 M O D E L E 4 The Model E4 is a general purpose chilled mirror dew point hygrometer which provides optional

More information

Control Solutions Biofloor

Control Solutions Biofloor MCF234 Distributor for Wired Control System COMAP proposes a new control system for heating and cooling underfloor. Consisting of a 6 or 10- channels controller (MCF234), analogic (TAF234) or electronic

More information

Product Data Sheet 4184 NXHH

Product Data Sheet 4184 NXHH The engineer's choice 4184 NXHH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating

More information

3. Packages 3.1 Characteristics Model number S4 (Package) Sensing element type Target gas VH Heater Voltage Electrical characteristics PH Powe

3. Packages 3.1 Characteristics Model number S4 (Package) Sensing element type Target gas VH Heater Voltage Electrical characteristics PH Powe E-MAIL: 1/7 Sensor (Carbon dioxide) for the detection of CO2 Features High selectivity to CO 2 Long-term stability Low dependency on humidity & temperature Applications Air quality control Agriculture

More information

CLASSEQ LTD. Spares manual P500 AS WS

CLASSEQ LTD. Spares manual P500 AS WS CLASSEQ LTD Spares manual P500 AS WS Spares manual 12/01/2018 Spares manual Page 2 P500 AS WS Table of contents for P500 AS WS 1. Machine assembly... 4 2. Front panel assembly... 6 3. Front Panel... 8

More information

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction GENERAL DESCRIPTION List: RH06-1F-1-July 016 4/3- and 4/- way directional control valves with solenoid operation, heavy duty construction Removable AC and DC voltage coils-quick replacement and rotation

More information

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY TOP QUALITY SOLUTIONS FOR YOUR LABORATORY Distributed By Polypropylene Ductless Fume Hood Easily dissembled back wall Tempered glass sliding front window Monitor displays fan s total operation time, for

More information

PEHLA Testing Station Ratingen ABB Medium Voltage Laboratories

PEHLA Testing Station Ratingen ABB Medium Voltage Laboratories Alex Steffens General Lab Manager PEHLA Testing Station Ratingen ABB Medium Voltage Laboratories 25.03.2010 Calor Emag Medium Voltage Products 1 Contact Alex Steffens + 49 2102 12 1351 alexander.steffens@de.abb.com

More information

Product Specification 11020CL0 DC-DC CONVERTER TRAIL CHARGER WITH LOCKOUTS

Product Specification 11020CL0 DC-DC CONVERTER TRAIL CHARGER WITH LOCKOUTS ISIONS DESCRIPTION DTE BY 001 5423 PRODUCTION RELESE 5/05/09 JT - - - - CORR WIRE DIG(SH11) BU-U144 6/15/11 JT Product Specification 110CL0 DC-DC CONVERTER TRIL CHRGER WITH LOCKOUTS PROPRIETRY THIS DRWING

More information

MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD

MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 ARE YOU A SHIPOWNER OPERATING IN EMISSIONS CONTROL AREAS ECAs? IS INCREASING SHIP EFFICIENCY YOUR TARGET? ARE FUEL SAVINGS STILL AN

More information

A E R Z E N S C R E W C O M P R E S S O R S

A E R Z E N S C R E W C O M P R E S S O R S A E R Z E N S C R E W C O M P R E S S O R S AERZEN - DELTA TWIN - Two Stage Screw Compressors Oil free compressed air technology A E R Z E N E R M A S C H I N E N F A B R I K G M B H V1-016 01 EN 2000

More information

Product Data Sheet 4184 NXHH

Product Data Sheet 4184 NXHH The engineer's choice 4184 NXHH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating

More information

FZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09

FZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09 FZ- Lubricator Electric, Oil & Grease General The FZ- Lubricator is primarily designed for direct feed applications for servicing up to 12 lubrication points. The lubricators are supplied with pump bodies

More information

Heating oven with mechanical control

Heating oven with mechanical control ED series 23 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the

More information

Product Data Sheet 8414 NGH

Product Data Sheet 8414 NGH The engineer's choice 8414 NGH INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating

More information

Product Data Sheet 4184 NGX

Product Data Sheet 4184 NGX The engineer's choice 4184 NGX INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating

More information

TYPE APPROVED CEMS GREEN EFFICIENCY ON BOARD

TYPE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 TYPE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 ARE YOU A SHIPOWNER OPERATING IN EMISSIONS CONTROL AREAS ECAs? IS INCREASING SHIP EFFICIENCY YOUR TARGET? ARE FUEL SAVINGS STILL AN ISSUE?

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Unit 1 Quatro Park Paycocke Road Basildon Essex SS14 3GH Contact: Mr E Martin Tel: +44 (0)1268 290115 Fax: +44 (0)1268 290123 E-Mail: eamonn.martin@mira.co.uk

More information

Industrial Relay KML(1C, 2C)

Industrial Relay KML(1C, 2C) Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations

More information

2012 Mustang Workshop Manual. 14. Position the lower radiator hose assembly into the vehicle. Connect the lower radiator hose to the radiator.

2012 Mustang Workshop Manual. 14. Position the lower radiator hose assembly into the vehicle. Connect the lower radiator hose to the radiator. 14. Position the lower radiator hose assembly into the vehicle. Connect the lower radiator hose to the radiator. 15. Connect the coolant hose to the oil cooler. 16. Rotate the SC drive belt tensioner clockwise

More information

Rittal TopTherm Filter Fans

Rittal TopTherm Filter Fans Rittal TopTherm Filter Fans More pressure. Higher air flow rates. 2 Installation without tools Snap-in mounting for easy installation Simple reversal of the air flow direction by turning the fan module

More information

Proportional pressure relief valve, directly operated, rising characteristic curve

Proportional pressure relief valve, directly operated, rising characteristic curve Proportional pressure relief valve, directly operated, rising characteristic curve RE 1139-0/09.07 Replaces: 0.05 1/1 Type KBPS.A (High-Performance) Component series A Maximum operating pressure 0 bar

More information

Heating oven with mechanical convection

Heating oven with mechanical convection FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous

More information

2000 Toyota Celica GT-S L4-1762cc 1.8L DOHC MFI - Removal and Installation

2000 Toyota Celica GT-S L4-1762cc 1.8L DOHC MFI - Removal and Installation Page 1 of 8 Removal and Installation REMOVAL 1. REMOVE HOOD Torque: 13 Nm (130 kgf-cm, 9 ft. lbs.) 2. REMOVE BATTERY 3. REMOVE ECM AND ECM CASE Torque: 6.9 Nm (70 kgf-cm, 61 inch lbs.) 4. REMOVE ECM BRACKET

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer APPLICATION NOTE 0_- DewMaster Rev Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer The Model DewMaster is a versatile, multi-function, optical chilled mirror hygrometer designed to continuously

More information

High Performance Thermal Circuit Breaker

High Performance Thermal Circuit Breaker High Performance Thermal Circuit Breaker 43-... Description Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 11238 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 09.02.2016 to 08.02.2021 Holder of certificate: ContiTech

More information

A44 W0...W2: Motorised actuator

A44 W0...W2: Motorised actuator A44 W0...W2: Motorised actuator How energy efficiency is improved Electric cut-off in end position to save energy Features Actuation of control units such as air dampers, gates, butterfly valves, etc.

More information

Technical File Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200)

Technical File Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200) Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200) Contents: 1 Components, settings and operating values of the engine which influence its NO x emissions Page 2 2 Full range of allowable adjustments

More information

With high speed to top quality

With high speed to top quality With high speed to top quality Stress Screening Systems WTS 3/WKS 3 Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik Reliable test results by means of reproducible environmental conditions Characteristics,

More information

Mistral LC-MS Evolution Specification

Mistral LC-MS Evolution Specification Mistral LC-MS Evolution Specification Flow Rate: Outlet Pressure: Purity : Power Consumption : Circuit Breaker: Pressure accuracy : Microprocessor controlled display : Operating conditions : temperature

More information

Broetje-Automation Company Standard Coating

Broetje-Automation Company Standard Coating Index 07 Broetje-Automation Company Standard Table of Contents Scope and Objective... 2 1 Standards and Corrosion Protection... 2 1.1 Standards... 2 1.2 Corrosion Resistance... 2 2 Surface Preparation...

More information

BENCHTOP SHAKING INCUBATOR

BENCHTOP SHAKING INCUBATOR PRODUCT CATALOG SHAKING INCUBATOR www.biolabscientific.com SHAKING INCUBATOR Bench top shaking incubator has a compact design that saves your precious lab space. Stainless steel interiors with exceptional

More information

WJ STEERING 19-1 STEERING CONTENTS POWER STEERING 3.1L VM DIESEL... 1 POWER STEERING PUMP 3.1L VM DIESEL... 2 POWER STEERING 3.

WJ STEERING 19-1 STEERING CONTENTS POWER STEERING 3.1L VM DIESEL... 1 POWER STEERING PUMP 3.1L VM DIESEL... 2 POWER STEERING 3. WJ STEERING 19-1 STEERING CONTENTS POWER STEERING 3.1L VM DIESEL... 1 POWER STEERING PUMP 3.1L VM DIESEL... 2 POWER STEERING 3.1L VM DIESEL GENERAL INFORMATION POWER STEERING PUMP...1 INDEX GENERAL INFORMATION

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Stratford Road Solihull West Midlands B90 4GW Contact: Mr C Gregory Tel: +44 (0)121 627 3225 Fax: +44 (0)121 627 4353 E-Mail: colin.gregory@trw.com Website:

More information