Mistral LC-MS Evolution Specification
|
|
- Jesse Norman
- 6 years ago
- Views:
Transcription
1 Mistral LC-MS Evolution Specification Flow Rate: Outlet Pressure: Purity : Power Consumption : Circuit Breaker: Pressure accuracy : Microprocessor controlled display : Operating conditions : temperature : relative humidity : Heat dissipation : 35 NL/min +/ 1.5 NL/min (at atmospheric pressure) 8 bar / 120 psi > 98% (less 2% O2) 1300 Watt 10A for 230V 15A for 110V 0.2 bar (+/ 0.1 bar) Graphic display, 128 x 64 pixels 10 C to 40 C 0 80 % rf, no condense / 0 99% rf with condense drain Approx 2700 BTU/h Dimensions Mistral LC-MS Evolution Flow rate (NL/min) 35 Net Weight (kg) 121 Shipping Weight (kg) 146 Dimensions (mm) (WxDxH) 482 x 835 x 641 Power consumption (Watt) 1300 Part Number: N2 MISTRAL LCMS Evolution 35Nl/min 230V/50Hz N2 MISTRAL LCMS Evolution 35Nl/min 230V/60Hz N2 MISTRAL LCMS Evolution 35Nl/min 115V/60Hz Options: O2 sensor Flow sensor 4000h LCMS Kit (1coalescent filter + 4 silencers)
2 NM-Plus Hydrogen Generator Specification Hydrogen purity : Electrolysis cell : Auto drying system : Delivery pressure : Fitting : Safety : User interface : Remote command : Cascading : Water : Dimensions : Weight: Shipping dimensions : Shipping weight: Power requirements : % Solid Polymer Membrane type (PEM) No maintenance system (exclusive design) psi / bar 1/8 for the H2 outlet Auto shut-off / low internal volume of H2 (< 40 ml) Set points, system status, user parameter / touch screen / LCD graphic display RS232/485 as option Up to 10 units (if the option is installed) Deionized or distilled < 10 µs conductivity 23x43x36 cm (W x H X D) 20 Kg 40x58x57 cm (W x H X D) 30 Kg 230V/50-60Hz - 110V/60Hz 100V/60Hz NM-Plus part numbers : AAA. B AAA = flow rate 010 = 100 Nml/min 016 = 160 Nml/min 025 = 250 Nml/min 030 = 300 Nml/min 050 = 500 Nml/min 060 = 600 Nml/min 100 = 1000 Nml/min B = Voltage 1 = Voltage 230V/50-60Hz 2 = Voltage 110V/60Hz 3 = Voltage 100V/60Hz Example : = NM-Plus 100Nml/min, voltage 230V/50-60Hz Options: I/O board (including cascading capabilities & RS232/485) PC Software (require I/O Board) Auto-refill kit (including Pump, external water compressor, fluidic & electrical connections) Deionizer LE triangle bag Deionizer LE bag (kit including 2 standard bags) Preventive maintenance kit for PG
3 PG-Plus Hydrogen Generator Specification Hydrogen purity : Electrolysis cell : Delivery pressure : Fitting : Safety : User interface : Remote command : Cascading : Water : Dimensions : Weight: Shipping dimensions : Shipping weight: Power requirements : % / hydrocarbon free < 0.1 ppm Solid Polymer Membrane type (PEM) psi / bar 1/8 for the H2 outlet Auto shut-off / low internal volume of H2 (< 40 ml) Set points, system status, user parameter / touch screen / LCD graphic display RS232/485 as option Up to 10 units (if the option is installed) Deionized or distilled < 10 µs conductivity 23x43x36 cm (W x H X D) 20 Kg 40x58x57 cm (W x H X D) 30 Kg 230V/50-60Hz - 110V/60Hz 100V/60Hz NM-Plus part numbers : AAA. B AAA = flow rate 010 = 100 Nml/min 016 = 160 Nml/min 025 = 250 Nml/min 030 = 300 Nml/min 050 = 500 Nml/min 060 = 600 Nml/min B = Voltage 1 = Voltage 230V/50-60Hz 2 = Voltage 110V/60Hz 3 = Voltage 100V/60Hz Example : = NM-Plus 100Nml/min, voltage 230V/50-60Hz Options: I/O board (including cascading capabilities & RS232/485) PC Software (require I/O Board) Auto-refill kit (including Pump, external water compressor, fluidic & electrical connections) Deionizer LE triangle bag Deionizer LE bag (kit including 2 standard bags) Preventive maintenance kit for PG
4 HP-N2 High Purity Nitrogen Station Specification Delivery pressure: Input pressure for model without compressor : N2 purity : Internal tank : Sound level : Particle filtration level: Fittings: User interface: Dimensions WxDxH [cm] : Shipping Dim WxDxH [cm] : Net weight [Kg] : Shipping weight [Kg] : Power consumptions [watt]: Power requirements: Up to 5 bar (75 psi) 7 bar min (110 psi) / Non condensing and oil free Air < 0.1 ppm Total Hydrocarbons with CH4 scrubber) < 50 C DP 8L to 32 L < 70 dba (with compressor only) 50 µm 1/4 Swagelok for outlet N2 and Inlet Air Pressure setting, system status, user parameter / Touch screen / LCD graphic display 36x64x67 with compressor or 35x40x30 without compressor 45x80x80 15 to 50 depending on options 15 to 60 depending on options 600 with compressor or 100 without compressor 230V/50Hz 230V/60Hz 115V/60Hz High Purity Nitrogen Station Flow rate (NL/min) Purity % % 99.99% 98% x HP N2 NC x HP N2 NC x HP N2 NC x HP N2 NC x HP N2 C x HP N2 C x HP N2 C x HP N2 C 4000 Optional CH4 scrubber C = Includes internal compressor (large casing) NC = Need external compressed Air (small casing) X=0 for 230V/50Hz or 230V/60Hz X=2 for 115V/60Hz X=4 for 100V/60Hz To have the option CH4 Scrubber please change the article number replacing the last 0 (in bold and red) by 1. Example : HP N2 C V/50Hz + CH4 = Set of air filters (coalescent V5 + dust)
5 Compressed Air Station Specification Delivery Pressure : Dew Point : Particles filtration level : Sound level : Drying system : Fittings : User interface : Stand by mode : Power requirements : Dimensions atm to 75 psig / atm to 5 barg for Mini Compressed Air station Up to 90 psig / up to 6 barg for Compressed Air station 20 & 40 < 0 C < 0.1 µm < 65 to 70 dba By coalescent filter and static dryer for Mini Compressed Air station By coalescent filter for Compressed Air station 20 & 40 Inlet Air 1/4 Swagelok / Outlet Air 1/8 Swagelok Pressure setting, system status, user parameter, Touch screen / LCD graphic display By request or automatically if no compressed air is required 230V/50 60HZ 115V/60Hz 100V/60Hz for Mini Compressed Air station 230V/50 60HZ 115V/60Hz for Compressed Air station 20 & 40 Mini Air Station Air Station 20 Air Station 40 Flow rate (NL/min) Net Weight (Kg) Shipping Weight (Kg) Dimensions (cm) (WxDxH) 16x35x25 36x64x67 36x64x67 Shipping Dim.(cm) 41x51x36 45x80x80 45x80x80 Power consumption (Watt) Part Number: Part Number: Mini compressed air station 1.5 NL/min, 230V/50 60Hz compressed air station 1.5 NL/min, 115V/60Hz Mini compressed air station 1.5 NL/min, 100V/60Hz Compressed air station 20 NL/min, Floor casing, 230V/50 60Hz Compressed air station 20 NL/min, Floor casing, 115V/60Hz Compressed air station 40 NL/min, Floor casing, 230V/50 60Hz Compressed air station 40 NL/min, Floor casing, 115V/60Hz Compressor kit for Mini compressed air station Inlet filter AF10 for Mini compressed air station Dust filter 1/8 for Mini compressed air station Coalescent filter for Compressed air station Dust filter for Compressed air station
6 GC Series Zero Air Generator Specification HC & CO out : Max temperature in : Working temperature : Pressure in : (factory set at 7 bar) Pressure drop : Stability : Connection in : Connection out : Power requirement : Dimensions (HxWxD): < 0.1 ppm 40 C Ambient + 15 C 4.5 to 10 bar < 1 bar 45 min 1/4 1/8 (NPT) 230V/50 60Hz or 115V/60Hz or 100V/60Hz 41 x 55 x 23 cm GC 1500 GC 3000 GC 6000 GC GC Flow rate (NL/min) Weight (kg) GC zero air generator 1.5 NL/min 230V/50 60Hz GC zero air generator 1.5 NL/min 115V/60Hz GC zero air generator 1.5 NL/min 100V/60Hz GC zero air generator 3 NL/min 230V/50 60Hz GC zero air generator 3 NL/min 115V/60Hz GC zero air generator 3 NL/min 100V/60Hz GC zero air generator 6 NL/min 230V/50 60Hz GC zero air generator 6 NL/min 115V/60Hz GC zero air generator 6 NL/min 100V/60Hz GC zero air generator 15 NL/min 230V/50 60Hz GC zero air generator 15 NL/min 115V/60Hz GC zero air generator 15 NL/min 100V/60Hz GC zero air generator 30 NL/min 230V/50 60Hz GC zero air generator 30 NL/min 115V/60Hz GC zero air generator 30 NL/min 100V/60Hz Filter housing complete with filter cartridge (external) Replacement cartridge for inlet filter Filter for zero air generator (internal)
7 GT Series Zero Air Generator Specification HC, CO, NOX, SOx out : CO2 out : Max temperature in : Working temperature : Pressure in : (factory set at 7 bar) Pressure drop : Stability : Connection in : Connection out : Power requirement : < 0.1 ppm < 5 ppm 40 C Ambient + 15 C 4.5 to 10 bar < 1 bar 45 min 1/4 1/8 (NPT) 230V/50 60Hz or 115V/60Hz or 100V/60Hz GT 1500 GT 3000 GT 6000 GT GT Flow rate (NL/min) Weight (kg) Dimensions cm (HxWxD) 41x55x25 41x55x25 41x55x25 47x63x31 47x63x GT zero air generator 1.5 NL/min 230V/50 60Hz GT zero air generator 1.5 NL/min 115V/60Hz GT zero air generator 1.5 NL/min 100V/60Hz GT zero air generator 3 NL/min 230V/50 60Hz GT zero air generator 3 NL/min 115V/60Hz GT zero air generator 3 NL/min 100V/60Hz GT zero air generator 6 NL/min 230V/50 60Hz GT zero air generator 6 NL/min 115V/60Hz GT zero air generator 6 NL/min 100V/60Hz GT zero air generator 15 NL/min 230V/50 60Hz GT zero air generator 15 NL/min 115V/60Hz GT zero air generator 15 NL/min 100V/60Hz GT zero air generator 30 NL/min 230V/50 60Hz GT zero air generator 30 NL/min 115V/60Hz GT zero air generator 30 NL/min 100V/60Hz Filter housing complete with filter cartridge (external) Replacement cartridge for inlet filter Filter for zero air generator (internal) Activated carbon column for models 1500 to 6000 Activated carbon column for models & 30000
8 Ultra Zero Air Station Specification Flowrate : Delivery pressure : Air purity : Particle filtration level : Sound level : Fittings : User interface : 6NL/min or 30NL/min Up to 5 barg (75 psi) < 0.1 ppm Total Hydrocarbons < 0.05 ppm CO / < 5 ppm CO2 / < 0.05 ppm NOx / < 50 C DP ( 58 F) 0.5 µm < 65 dba Outlet Air 1/4 Swagelok Pressure setting, system status, user parameter / Touch screen / LCD graphic display Dimensions [cm] : Shipping Dim [cm] : 36x64x67 45x80x80 (WxDxH) (WxDxH) Power requirements : 230V/50Hz 230V/60Hz 115V/60H Air flow rate [NL/min] max 6 30 Net weight [Kg] Shipping weight [Kg] Power consumption [Watt] Ultra zero air station 6Nl/min. Floor casing. 230V/50 60Hz Ultra zero air station 6Nl/min. Floor casing. 115V/60Hz Ultra zero air station 30Nl/min. Floor casing. 230V/50 60Hz Ultra zero air station 30Nl/min. Floor casing. 115V/60Hz Air : set of filters (coalescent V5 + dust)
9 Zero Air Station Specification Flowrate : Delivery pressure : Air purity : Particle filtration level : Sound level : Fittings : User interface : 6NL/min or 30NL/min Up to 6 barg (75 psi) < 0.1 ppm Total Hydrocarbons <0.1 µm < 65 dba Outlet Air 1/4 Swagelok Pressure setting, system status, user parameter / Touch screen / LCD graphic display Dimensions [cm] : Shipping Dim [cm] : 36x64x67 45x80x80 (WxDxH) (WxDxH) Power requirements : 230V/50Hz 230V/60Hz 115V/60H Air flow rate [NL/min] max 6 30 Net weight [Kg] Shipping weight [Kg] Power consumption [Watt] Zero air station 6NL/min. Floor casing. 230V/50 60Hz Zero air station 6NL/min. Floor casing. 115V/60Hz Zero air station 30NL/min. Floor casing. 230V/50 60Hz Zero air station 30NL/min. Floor casing. 115V/60Hz Air : set of filters (coalescent V5 + dust)
10 Air 1.5 L/min, 20 L/min and 40 L/min Compressed Air Stations. ZAS (Zero Air Station) suitable for GC FID applications. UZAS (Ultra Zero Air Station) for applications requiring ultimate purity. ZAS and UZAS available in 6 L/min and 30 L/min versions, with or without air compressor. Compressed Air Station Laboratory Gas Generators ZAS no compressor UZAS no compressor ZAS UZAS
11 Hydrogen LNI Schimidlin's NM-Plus and PG-Plus hydrogen generators utilise the latest Proton Exchange Membrane (PEM) technology for the electrolytic production of pure hydrogen from deionised water. Operation is almost completely silent. Internal hydrogen volume is less than 40ml. Auto-shutdown in the event of an error Unique Schimidlin Cascade option connect multiple units for additional flow capacity and backup for critical applications Unique No Maintenance NM-Plus model - No Maintenance Pressure Swing Adsorption (PSA) auto-drying technology, no desiccant to change. Hydrogen purity > % with NM-Plus. Flow rate up to 1000ml/min. The HP-N2 delivers up to % purity nitrogen, suitable for GC carrier and detector applications. 500 ml/min up to 4,000 ml/min at 5 bar. PSA (Pressure Swing Adsorption) technology. Available with or without internal air compressor. HP-N2 High Purity Nitrogen Nitrogen NM-Plus PG-Plus The Mistral LCMS Evolution delivers 98% purity, flow rate up to 35 L/min at up to 8 bar pressure. PSA technology. Includes internal air compressor. Mistral LCMS Evolution Generate your own superior, sustainable and safe carrier gas!
Nexa 1200 Fuel Cell System
Systems Fuel Cell System The is the successor to the popular Nexa Power Module. Based on the modern FCgen 1020 stack from Ballard, the system provides an output of 1200 W. The fully integrated power module
More informationGENCORE 5 FUEL CELL SYSTEM System Fundamentals
GENCORE 5 FUEL CELL SYSTEM System Fundamentals GenCore 5T48 GenCore 5B48 GenCore 5U48 GenCore 5T24 GenCore 5U120 Revision 1 December 1, 2004 GENCORE DESCRIPTION GenCore fuel cell systems are direct hydrogen
More informationUltra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS
ULTRA CLEAN GAS FILTERS ULTRA CLEAN GAS FILTERS Table of Contents Ultra Clean Gas Filter s for GC and GC/MS...3 Triple Filter for MS/ECD/NPD... 3 Complete Triple Filter Bundle for FID...3 Complete Triple
More informationBioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced
1 Data Sheet Bioengineering RALF Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. The glass vessels have both a round bottom and stainless steel lid. The system
More informationN.GEN ON-SITE NITROGEN GENERATION SYSTEM COST-EFFECTIVE NITROGEN GENERATION
N.GN ON-SIT NITROGN GNRATION SYSTM COST-FFCTIV NITROGN GNRATION NGINRING FOR SUSTAINABL GROWTH NRGY FFICINT NITROGN GNRATION HyGear offers Nitrogen supply ranging from 100 Nm 3 /h to 3000 Nm 3 /h by means
More informationCNG FILTRATION. Natural Gas Vehicle (NGV) Filters. Trucks Vans Cars Forklifts.
CN FILTRATION Trucks Vans Cars Forklifts Natural as Vehicle (NV) Filters www.xebecinc.com What is Compressed Natural as (CN)? Compressed Natural as (CN) is clean energy a readily available and affordable
More informationLABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL
LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL Content 1. Introduction...2 2. Important safety instruction...3 3. System component...4 4. Engineering design overview...5 5. Installation...6
More informationGC Instruments GC Columns GC Accessories
GC GC Instruments................. 200 212 GC Systems & Data Collection........... 200 205 Gas Generators Hydrogen......................... 206 207 Air............................ 208 209 Nitrogen............................
More informationPortable TOC Analyser for Stack Emissions
Portable TOC Analyser for Stack Emissions Lightweight, compact, safe and SMART Size and Weight SPECIFICATIONS 355(W) x 155(H) x 426(D) mm, 10 Kg (with batteries 13,4 Kg) Power Supply External Power Adapter
More informationLightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
More informationLAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C
LAUDA Integral Process thermostats for professional external thermostating across a wide temperature range from -9 up to C Application examples Process technology Process engineering Production Research
More informationCFPP Process Analyzer
Norms and standards CFPP ASTM D 6371 DIN EN 116 IP 309 Application The BARTEC BENKE CFPP (CFPP-4) is suited to analyze the standardized value of Cold Filter Plugging Point (CFPP) in a process stream online
More informationCHAPTER 3 : TYPE I TEST ON SI ENGINES (VERIFYING THE AVERAGE EMISSIONS OF GASEOUS POLLUTANTS)
CHAPTER 3 : TYPE I TEST ON SI ENGINES (VERIFYING THE AVERAGE EMISSIONS OF GASEOUS POLLUTANTS) 1. This chapter describes the procedure for the Type I test defined in paragraph 5.2.2 of Chapter 1 of this
More informationVWR Zero Air Generator
Technical Information Installation, Operation, and Maintenance Manual VWR 89237-564 Zero Air Generator Figure 1 - VWR Zero Air Generator These instructions must be thoroughly read and understood before
More informationTechnical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer
Technical Offer Antek Model 6200 Analyzer 2015.4 Determine Total Sulfur and Total Nitrogen in a single analyzer Meet sulfur regulations and control your process with continuous sulfur and/or nitrogen measurements
More informationRecirculating Coolers
SELECTION GUIDE (General Models) (Low Temp. Models) (Advanced Low Temp. Models) (High Temp. Models) General Models Low Temp. Models Advanced Low Temp. Models High Temp. Models HX-20 Working Cooling Temp.
More informationWeather-Proof Thermal Mass Flow Meter for Pipe - Duct
MF200A Series Weather-Proof Thermal Mass Flow Meter for Pipe - Duct Feature & Application n Accuracy ±1.0% reading n Watch-dog software n Wide turn-down ratio 300 : 1 n Repeatability ±0.15% FS n 16 x 2
More informationANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application
2-3.1 ATC 510/520/525 for wall-mounting Application The ATC 510/5205/525 is a modern microprocessor-based (PID) control device featuring easy handling and a digital display. The clear design of the operator
More informationFlash Point Process Analyzer
Norms and standards ASTM D 56 ASTM D 93; DIN EN ISO 2719; IP 34 DIN EN ISO 13736; IP170 DIN 51755 Application The BARTEC BENKE Flash Point Process Analyzer (FPA-4) is a continuously measuring analyzer,
More informationBIOSTAT D+ 100 MICROBIAL FERMENTER SYSTEM
BIOSTAT D+ 100 MICROBIAL FERMENTER SYSTEM Sartorius BBI Systems GmbH P. O. Box 13 63 D - 34203 Melsungen Tel.: 0049-5661-71 38 42 Fax: 0049-5661-92 99 49 www.sartorius-bbi-systems.de info@sartorius-bbi-systems.com
More informationHPZA-3500, HPZA-7000, HPZA-18000, HPZA-30000
Models HPZA-3500, HPZA-7000, Installation, HPZA-18000, Operation, HPZA-30000and Maintenance Manual Technical Information Parker Balston Zero Air Generators HPZA-3500, HPZA-7000, HPZA-18000, HPZA-30000
More informationAir Filtration CLEARPOINT. energy saving compressed air filtration. Truth in Compressed Air.
Air Filtration CLEARPOINT energy saving compressed air filtration Truth in Compressed Air. At a Glance CLEARPOINT Filters uring compressed air generation and distribution, contaminants are introduced to
More informationSentronic PLUS 614 Series
Sentronic PLUS 64 Series Proportional Technology www.asco.com PRESSURE CONTROL: 64 SERIES SENTRONIC PLUS Sentronic PLUS Sentronic PLUS is a digitally operated pressure regulator valve. This valve accurately
More information1. Important Safety Warning
Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation... 1 1-5. Maintenance, service and faults... 2 2. Installation and
More informationMARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD
S-Keeper 7 MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 ARE YOU A SHIPOWNER OPERATING IN EMISSIONS CONTROL AREAS ECAs? IS INCREASING SHIP EFFICIENCY YOUR TARGET? ARE FUEL SAVINGS STILL AN
More informationF200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades
F200 Series Compressed Air and Gas s FEATURES Heavy duty cast aluminum housings Maximum working pressure 250 PSIG Nine filtration grades Push on filter elements BENEFITS OF THE F200 SERIES Rugged construction
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Installation, Operation and Maintenance Parker Balston 75-83 Zero Air Generator Figure 1 - Parker Balston 75-83 Zero Air Generator These instructions must be thoroughly read and understood
More informationUSER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4
USER S MANUAL PowerWalker VFI 1000 / 3000VA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION......... 2 3. SYSTEM DESCRIPTION......... 4 4. CABLE CONNECTION......... 7 5. OPERATION...... 8 6. TROUBLE
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.
More informationProduce it at a lower cost! TKA Ion exchangers!
Fully demineralized water Produce it at a lower cost! TKA Ion exchangers! Deionized water for autoclaves, washers, automatic analyzers, ultrapure water systems... WATER PURIFICATION SYSTEMS Fully demineralized
More informationUser Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work
GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)
More informationFTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE
FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE TABLE OF CONTENTS SECTION 1 General Information: Model Description Pg 2 Serial Numbers Description of Operation SECTION 2 Safety Instructions: Pg
More information973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS
Portable Industrial Chilled Mirror Hygrometer Fundamental drift free humidity measurement Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System for fast measurement
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible
More informationTHC Heated FID 3-300A
Rack Mount/Table Top TVOC Analyzer THC Heated FID 3-300A Space saving 19"/3PU space saving rack mount and table top heated emission analyzer for the continuous determination of the mass concentration of
More informationecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity
Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans
More informationN.GEN ON-SITE NITROGEN GENERATION SYSTEM COST-EFFECTIVE NITROGEN GENERATION
N.GN ON-SIT NITROGN GNRATION SYSTM COST-FFCTIV NITROGN GNRATION NGINRING FOR SUSTAINABL GROWTH NRGY FFICINT NITROGN GNRATION Nitrogen can be generated on-site with HyGear s N.GN. On-site nitrogen production
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationPAHT pumps / PAHT G pumps / ATEX PAHT G pump
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet PAHT 2-308 pumps / PAHT G 2-308 pumps / ATEX PAHT G pump danfoss.high-pressurepumps.com Table of Contents
More informationPR70. Meter, Mix and Dispense Systems - Ordering Information PROVEN QUALITY. LEADING TECHNOLOGY.
PR70 Meter, Mix and Dispense Systems - Ordering Information PROVEN QUALITY. LEADING TECHNOLOGY. PR70 System Comparisons PR70e with LCM PR70 with DM PR70 with ADM PR70v with ADM System Configured system?
More informationTC-9 Rapid Thermal Chamber Specifications
T-9 Specification www.hanseenv.com +1-269-673-8638 T-9 Rapid Thermal hamber Specifications 5/21/15 Page 1 of 8 REV 2.0 T-9 Specification www.hanseenv.com +1-269-673-8638 System Features 3 Summery of Hanse
More informationNB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS
NB 0811 - NB 1511 NB 0831 - NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS LEN.MAN.UPS.069 Rev.2.00/2002 CONTENTS Safety Instructions 1 Introduction 3 2.1 FEATURE 3 2.2 UPS modules 4 How the UPS works 5 3.1
More informationUser Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality
GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply
More informationAgilent 7693A Automated Liquid Sampler
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7693A Automated Liquid Sampler
More informationabc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.
CPD7948/075 Specification Oil-Free, Air Cooled, Rotary Screw Compressors - Dryclon Range Models D75, D90, D110, D132, D150 (50Hz) D55, D75, D90, D110, D150 (60Hz) COMPRESSOR PACKAGE An enclosed two stage
More informationJUMO ecotrans Lf 01/02
Data Sheet 07 Page /7 JUMO ecotrans Lf 0/0 Microprocessor Transmitter/Switching Device for Conductivity Housing for DIN rail mounting (5 mm 7.5 mm to EN 075 A.) Brief description The JUMO ecotrans Lf 0/0
More informationCompact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1
Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas
More informationF200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades
F200 Series Compressed Air and Gas s FEATURES Heavy duty cast aluminum housings Maximum working pressure 250 PSIG Nine filtration grades Push on filter elements BENEFITS OF THE F200 SERIES Rugged construction
More informationTYPE APPROVED CEMS GREEN EFFICIENCY ON BOARD
S-Keeper 7 TYPE APPROVED CEMS GREEN EFFICIENCY ON BOARD S-Keeper 7 ARE YOU A SHIPOWNER OPERATING IN EMISSIONS CONTROL AREAS ECAs? IS INCREASING SHIP EFFICIENCY YOUR TARGET? ARE FUEL SAVINGS STILL AN ISSUE?
More informationTECHNICAL INFORMATION
1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY (RATIO 1:20) Lbs 40 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 35.4 inches 21 gal 90 rpm 12 50 rpm 300 540 inches
More information-86 0 C FREEZER. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.
-86 0 C FREEZER www.labocon.com NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. LUF-86-100 SERIES Labocon -86 C Ultra Low Temperature
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS AVR Protection
More informationDoosan XHP1170FCAT Bid Specifications
MANUFACTURER MODEL Doosan Infracore XHP1170FCAT ENGINE TIER 3 Make CATERPILLAR Model C-15 Number of Cylinders 6 Cylinder Bore (in/mm) 5.4 (137) Cylinder Stroke (in/mm) 6.73 (15.2) Displacement (cu in/l)
More informationVarian, Inc. Vacuum Technologies. TPS Turbo Pumping Systems. Features and Benefits 2-3. Mini-TASK AG TPS-compact 6-7
Varian, Inc. Vacuum Technologies TPS Turbo Pumping Systems Features and Benefits 2-3 Mini-TASK AG81 4-5 TPS-compact 6-7 TPS-mobile and TPS-bench 8-10 TPS Turbo Pumping Systems Features and Benefits The
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency AVR Protection Compact
More informationHydraulic Test Equipment For A350 (Pre-Fal) >HTE350<
Hydraulic Test Equipment For A350 (Pre-Fal) HYDRAULICS >HTE350HAM< Hamburg >HTE350GTF< Getafe >HTE350SEL< Saint-Éloi >HTE350STD< Stade >HTE350BRE< Bremen >HTE350BRO< Broughton >HTE350SNZ< Saint-Nazaire
More informationSentronic D 608 Series and 609 Series
Sentronic D 608 Series and 609 Series Proportional Technology www.asco.com PRESSURE CONTROL: 608/609 SERIES SENTRONIC D Sentronic D Sentronic D is a digitally operated pressure regulator valve. Sentronic
More informationDeployable Hydrogen Fuel Supply for Clean and Quiet Power Joint Service Power Expo Session 3: Fuel Cells May 2, 2017
Deployable Hydrogen Fuel Supply for Clean and Quiet Power 2017 Joint Service Power Expo Session 3: Fuel Cells May 2, 2017 Company Overview.for today World leader in PEM water electrolysis HQ in Wallingford,
More informationSULLAIR. oil free. Rotary Screw Air Compressors hp kw
SULLAIR oil free Rotary Screw Air Compressors 100 200 hp 75 150 kw sullair an industry leader Leadership Since 1965, Sullair has been recognized worldwide as an innovator and leader in rotary screw compression
More informationYour Plant Deserves Pure-Aire!
Your Plant Deserves Pure-Aire! PF Series High Efficiency Filters High Technology Filter Elements The Pure-Aire PF Series High Efficiency Unique Push-Fit, Double O-Ring Seal filter-to-head chamfered connection
More informationSmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9
SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 MODEL NUMBER: AL-84111 Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kva Capacity
More informationGAS ANALIZERS SMOKEMETERS STARGAS FAMILY
GAS ANALIZERS S STARGAS FAMILY GAS ANALYZER - 488OTC 488OTC is an infrared exhaust gas analyzer for gasoline engines. Tests conducted with 488OTC allow operators to measure CO, CO2, HC, O2 values according
More informationTECHNICAL INFORMATION
1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY Lbs 60 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 39.4 inches 25.2 gal 132 rpm 12 50 rpm 300 540 inches 20 SOLVENT
More informationAgilent 7693A Automated Liquid Sampler
Agilent 7693A Automated Liquid Sampler Specifications Overview The Agilent 7693A is a state-of-the-art sample handling and injection system that provides the highest levels of precision and reliability
More informationVane Air Motors - P1V-B
Vane Air Motors - P1V-B These large motors are designed for use in the most arduous applications, requiring considerable power, torque, robustness and reliability Operating information Working pressure:
More informationSULLAIR. oil free. Rotary Screw Air Compressors hp kw
SULLAIR oil free Rotary Screw Air Compressors 100 200 hp 75 149 kw sullair an industry leader Leadership Since 1965, Sullair has been recognized worldwide as an innovator and leader in rotary screw compression
More informationLDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.
LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems. LDX-U20 monitors the voltage supplied by a DC source and in case of power failure a backup battery is connected
More informationWater Cooled Air Compressors. The most convenient, efficient and effective way to cool your high pressure compressor.
Water Cooled Air Compressors The most convenient, efficient and effective way to cool your high pressure compressor. Rev. 04.19 NUVAIR WATER COOLED MCH13 / MCH16 COMPRESSOR FEATURES Cools each stage to
More informationMINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS
MINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS SPORTS & SAFETY 2 MINI-VERTICUS & VERTICUS BAUER KOMPRESSOREN MINI-VERTICUS & VERTICUS STATIONARY COMPRESSORS REINVENTED
More information500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION
High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry FEATURES Primary standard, dimensionally based piston prover system Accuracy: CalTrak 500: up to +/- 0.35% of reading mass
More informationSILOXA FAKA Gas Cleaning System
1/8 Activated carbon adsorber for removing H 2 S from biogas SILOXA s FAKA gas cleaning systems are highly efficient systems that are available in different versions, with one or two chambers or as a TWIN
More informationService unit combinations MSB, MS series
Service unit combinations MSB, MS series q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement
More informationSCREW COMPRESSORS OIL-FREE
SCREW COMPRESSORS OIL-FREE Over 100,000 compressed air users expect more when it comes to their compressed air supply. BOGE air provides them with the air to work. BOGE oil-free screw compressors have
More informationAgilent 6850 Series II Network GC System G2630A Performance Specifications
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 6850 Series II Network GC
More informationAPP S 674 pumps APP S / APP S APP S
MAKING MODERN LIVING POSSIBLE Data sheet APP S 674 3.0-3.5 / APP S 674 5.1-9.0 APP S 674 21-38 ro-solutions.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Application areas...3 4. Technical
More informationNOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw
Oil injected rotary screw compressors with direct transmission. NOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw NOBEL - NOBEL DV Rotary screw compressors featuring direct
More informationOnline data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS
Online data sheet A B C D E F H I J K L M N O P Q R S T 15267 14181 certified certified Ordering information Type Part no. On request The exact device specifications and performance data of the product
More informationVSO - MI thermally compensated proportional valve
The VSO - MI is a miniature proportional valve specifically designed for medical device manufacturers and incorporates thermal compensation to provide precise flow control and stability over a wide operating
More informationInstallation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA
Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
More informationBack-UPS CS Back-UPS CS 350
Back-UPS CS Back-UPS CS 350 APC Back-UPS CS, 210 Watts / 350 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, USB Includes: CD with software, Cord management straps, USB cable, User Manual Standard
More informationMiniature Pneumatic Solenoid Valve
V Valve 15 mm Pneumatic Solenoid Valve Typical Applications Oxygen Conservers Flow control/shut-off valve Portable Medical Devices Product Specifications Mechanical Valve Type: /3 Port, Direct-acting poppet
More informationAPP pumps APP / APP / APP (W) / APP / APP / APP Lenntech. Data sheet
MAKING MODERN LIVING POSSIBLE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet APP pumps APP 0.6-1.0 / APP 1.5-3.5 / APP (W) 5.1-10.2 / APP 11-13 / APP 16-22
More informationALD3 Diaphragm Valve Technical Report
ALD Diaphragm Valve Technical Report Scope This technical report provides data on Swagelok ALD normally closed diaphragm valves. The report covers: helium seat leak testing valve flow consistency analysis
More informationVarian, Inc. Vacuum Technologies. Rotary Vane Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models 6-19.
Varian, Inc. Vacuum Technologies Rotary Vane Pumps Features and Benefits 2-3 Typical Applications 4-5 Pump Models 6-19 Accessories 20 Frequency Inverter Technology 21 HS Series Pumps 22-25 MS40+ Features
More informationOxymat A/S :: Fasanvej :: DK-3200 Helsinge :: Denmark :: Tel :: Nm³/hour 3.0. Kilos/hour 3.5.
OXYMAT NITROGEN GENERATOR Model N-40 99.0% Nitrogen purity rate 99.0% Nm³/hour 3.0 Kilos/hour 3.5 Litres/minute 50 Nominal air feed Nm³/min. at min. 7 bar 0.13 Power consumption generator kw 0.1 Power
More informationMass Flow Meter Model: MAS. Design
Mass Flow Meter and Controller for Gases measuring monitoring analysing MS / MFC OMeasuring O range: 0-10 Nml/min... 0-500 Nl/min O O ccuracy: ±1.5% f.s. OO p max 35 bar; t max 50 C Onalogue O output:
More informationApplication. Battery. Public Grid GS HYBRID INVERTER
GS HYBRID SOLAR INVERTER Feed from Solar and Power, Grid backup, Build-in Transfer Switch / Solar Charger/ AC Charger, 500W~3kW, Pure Sine Wave Output GSH-15XX and GSH-30XX are the ideal solutions for
More informationQUANTUM LX CONTROL PANEL
Form E90-020 SPC (APR 2006) File: EQUIPMENT MANUAL - Section 90 Replaces: E90-020 SPC (JUN 2005) Dist: 1, 1a, 1b, 1c, 4a, 4b, 4c QUANTUM LX CONTROL PANEL The most technologically advanced screw compressor
More informationES20 Compact Sampling System Stainless Steel Sampling System
ES0 Compact Sampling System Stainless Steel Sampling System Dew-Point Sampling The ES0 Compact Sampling System is designed to reliably and accurately measure dew point or moisture content in a wide variety
More informationOil-free piston compressors KK and piston vacuum pumps KV
Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols
More informationColtri Asia Pacific ERGO & MINITECH BREATHING AIR
asia pacific Coltri Asia Pacific ERGO & MINITECH BREATHING AIR CATALOG 2017 High and low pressure compressors for pure breathing air - nitrox and technical gases c o l t r i.co m FILLING STATIONS Page
More informationHigh efficiency compressed air filtration & water separation
02 GB High efficiency compressed air filtration & water separation Innovative Compressed Air Purification CF & X RANGE A filter range you can trust The reliability of compressed air filtration is paramount
More informationCLASS II BIOSAFETY CABINET
PRODUCT CATALOG CLASS II BIOSAFETY CABINET www.biolabscientific.com CLASS II BIOSAFETY CABINET Biolab Biological Safety Cabinet Class II Series is engineered specifically for laboratory operations that
More informationMAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com
MAKING MODERN LIVING POSSIBLE Data sheet Data sheet APP 11-13 ro-solutions.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Technical data...4 4. Variants...4 5. Flow at different rpm....5
More informationExperience the Difference
ABB-Totalflow Experience the Difference PGC1000 Process Gas Chromatograph ABB Group October 19, 2011 Slide 1 Process GC Experience ABB introduced the Btu-8000 in 1995 C6+ application suitable for custody
More informationProviding a constant temperature control and high cooling efficiency.
Recirculating Coolers (General) Providing a constant temperature control and high cooling efficiency. Performance Temperature range from 3 to 40. High cooling capacity up to 7.1kW at 20. Powerful circulating
More informationRALF At a glance. Bioengineering RALF essentials. General
0845-12b RALF 6 1/16 RALF At a glance Bioengineering RALF essentials General Autoclavable small benchtop glass reactor Versatile reactor system for numerous different applications Single as well as multiple
More informationIE3. BOGE C series. Motor. Premium Efficiency. BOGE Competence
BOGE C series IE3 Motor Premium Efficiency BOGE Competence Over 100,000 compressed air users expect more when it comes to their compressed air supply. BOGE Air provides them with the air to work. Screw
More informationWater pumps for Desalination APP 16-22
Data sheet Water pumps for Desalination APP 16-22 ro-solutions.com APP16-22 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater reverse osmosis filtration
More information