Catalog JR(H/V)54(B/B+)

Size: px
Start display at page:

Download "Catalog JR(H/V)54(B/B+)"

Transcription

1 Catalog JR(H/V)54(B/B+) JAKKA heat recovery unit JAK-KA GROUP septembar J.8.Г

2 Content Description... 2 Product range... 3 Why the heat recovery is important?... 4 Dimensions... 5 Technical Data Configuration Control Smart Installation and accessories Jakka Group se trudi da tehničke karakteristike, opisi, fotografije i cene u katalozima i cenovnicima budu što tačniji, ali ne možemo da garantujemo da su sve informacije kompletne i bez grešaka. S toga Vas molimo, u cilju bolje saradnje, da pre konačne odluke proverite podatke sa prodavcem sa kojim sarađujete, kako bismo izbegli moguće greške. Jakka Group zadržava pravo promene svih informacija u katalozima, uputstvima i cenovnicima bez prethodne najave. 1

3 JAKKA Heat recovery units JR(H/V)54(B/B+) Description The heat recovery units JAKKA are designed for installation in: B B Construction of anodized aluminium profiles. Side panels produced in two versions: - Single panel with inner insulation (13mm - indoor installation); standard for 400, 600, 1000, 2000, 3000 and 3600 models. - Duoble panels "sandwich" insulation (25mm - outdoor installation); standard for 4200, 6000 and 8000 models. There is possibility to change the directions of fresh and exhausted air by changing the place of the side panels (see p.17). Drain connection is located at the bottom side. m 3 /h

4 Product range JAKKA Heat recovery units JR(H/V)54(B/B+) Product range of 9 JR(H/V)54(B/B+) models cover air flows from 250 up to 8500 m3/h Heat recovery units could bedesigned as monoblock ( ) or as spil systems ( ), allowing easy transport and installation. Acoording to the room specificationsthey could be produced for horiyontal or vertical installation JRH54(B/B+) JRH54(B/B+) H JRH54(B/B+) BS JRH54(B/B+) HBS JRV54(B/B+) JRV54(B/B+) H JRV54(B/B+) BS JRV54(B/B+) HBS JR(H/V)54(B/B+)/ Configuration: A, B, C or D (see p. 18) H - model with water heat exchanger BS - model with by-pass HBS - model with by-pass and water heat exchanger s - 400, 600, 1000, 2000, 3000, 3600, 4200, 6000 and 8000 B - standard recuperator B+ - recuperator with higher efficiency (up to 65%) H - horizontal installation V - vertical installation 3

5 JAKKA Heat recovery units JR(H/V)54(B/B+) Why the heat recovery is important? 4

6 Dimensions JAKKA Heat recovery units JR(H/V)54(B/B+) JRH54(B/B+) Horizontal installation Monoblock unit JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+) Horizontal installation Split unit JRH54(B/B+)/ JRH54(B/B+)/ Side panels of the supply and suction side of the unit are interchanngable. In this way, if is possible to make different configurations (see p. 17). As standard this units are produced with rectangular connections. We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product develepment. 5

7 JAKKA Heat recovery units JR(H/V)54(B/B+) Dimensions JRV54(B/B+) Vertical installation Monoblock unit JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+) Vertical installation Split unit JRV54(B/B+)/ JRV54(B/B+)/ Side panels of the supply and suction side of the unit are interchanngable. In this way, if is possible to make different configurations (see p. 17). As standard this units are produced with rectangular connections. We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product develepment. 6

8 Dimensions JAKKA Heat recovery units JR(H/V)54(B/B+) JRH54(B/B+) H Horizontal installation Monoblock unit JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+)/ JRH54(B/B+) H Horizontal installation Split unit JRH54(B/B+)/ JRH54(B/B+)/ Side panels of the supply and suction side of the unit are interchanngable. In this way, if is possible to make different configurations (see p. 17). As standard this units are produced with rectangular connections. We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product develepment. 7

9 JAKKA Heat recovery units JR(H/V)54(B/B+) Dimensions JRV54(B/B+) H Vertical installation Monoblock unit JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+)/ JRV54(B/B+) H Vertical installation Split unit JRV54(B/B+)/ JRV54(B/B+)/ Side panels of the supply and suction side of the unit are interchanngable. In this way, if is possible to make different configurations (see p. 17). As standard this units are produced with rectangular connections. We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product develepment. 8

10 Dimensions JAKKA Heat recovery units JR(H/V)54(B/B+) JRH54(B/B+) BS Horizontal installation Monoblock unit JRH54(B/B+)/400 BS JRH54(B/B+)/600 BS JRH54(B/B+)/1000 BS JRH54(B/B+)/2000 BS JRH54(B/B+)/3000 BS JRH54(B/B+)/3600 BS JRH54(B/B+)/4200 BS JRH54(B/B+) BS Horizontal installation Split unit JRH54(B/B+)/6000 BS JRH54(B/B+)/8000 BS Side panels of the supply and suction side of the unit are interchanngable. In this way, if is possible to make different configurations (see p. 17). As standard this units are produced with rectangular connections. We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product develepment. 9

11 JAKKA Heat recovery units JR(H/V)54(B/B+) Dimensions JRV54(B/B+) BS Vertical installation Monoblock unit JRV54(B/B+)/400 BS JRV54(B/B+)/600 BS JRV54(B/B+)/1000 BS JRV54(B/B+)/2000 BS JRV54(B/B+)/3000 BS JRV54(B/B+)/3600 BS JRV54(B/B+)/4200 BS JRV54(B/B+) BS Vertical installation Split unit JRV54(B/B+)/6000 BS JRV54(B/B+)/8000 BS Side panels of the supply and suction side of the unit are interchanngable. In this way, if is possible to make different configurations (see p. 17). As standard this units are produced with rectangular connections. We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product develepment. 10

12 Dimensions JAKKA Heat recovery units JR(H/V)54(B/B+) JRH54(B/B+) HBS Horizontal installation Monoblock unit JRH54(B/B+)/400 HBS JRH54(B/B+)/600 HBS JRH54(B/B+)/1000 HBS JRH54(B/B+)/2000 HBS JRH54(B/B+)/3000 HBS JRH54(B/B+)/3600 HBS JRH54(B/B+)/4200 HBS JRH54(B/B+) HBS Horizontal installation Split unit JRH54(B/B+)/6000 HBS JRH54(B/B+)/8000 HBS Side panels of the supply and suction side of the unit are interchanngable. In this way, if is possible to make different configurations (see p. 17). As standard this units are produced with rectangular connections. We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product develepment. 11

13 JAKKA Heat recovery units JR(H/V)54(B/B+) Dimensions JRV54(B/B+) HBS Vertical installation Monoblock unit JRV54(B/B+)/400 HBS JRV54(B/B+)/600 HBS JRV54(B/B+)/1000 HBS JRV54(B/B+)/2000 HBS JRV54(B/B+)/3000 HBS JRV54(B/B+)/3600 HBS JRV54(B/B+)/4200 HBS JRV54(B/B+) HBS Vertical installation Split unit JRV54(B/B+)/6000 HBS JRV54(B/B+)/8000 HBS Side panels of the supply and suction side of the unit are interchanngable. In this way, if is possible to make different configurations (see p. 17). As standard this units are produced with rectangular connections. We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product develepment. 12

14 Technical Data JAKKA Heat recovery units JR(H/V)54(B/B+) JR(H/V)54(B/B+)/400 Recuperativ heat exchanger B Recuperativ heat exchanger B+ JR(H/V)54(B/B+)/600 Recuperativ heat exchanger B Recuperativ heat exchanger B+ JR(H/V)54(B/B+)/1000 Recuperativ heat exchanger B Recuperativ heat exchanger B+ 13

15 JAKKA Heat recovery units JR(H/V)54(B/B+) Technical Data JR(H/V)54(B/B+)/2000 Recuperativ heat exchanger B Recuperativ heat exchanger B+ JR(H/V)54(B/B+)/3000 Recuperativ heat exchanger B Recuperativ heat exchanger B+ JR(H/V)54(B/B+)/3600 Recuperativ heat exchanger B Recuperativ heat exchanger B+ 14

16 Technical Data JAKKA Heat recovery units JR(H/V)54(B/B+) JR(H/V)54(B/B+)/4200 Recuperativ heat exchanger B Recuperativ heat exchanger B+ JR(H/V)54(B/B+)/6000 Recuperativ heat exchanger B Recuperativ heat exchanger B+ JR(H/V)54(B/B+)/8000 Recuperativ heat exchanger B Recuperativ heat exchanger B+ 15

17 JAKKA Heat recovery units JR(H/V)54(B/B+) Technical Data JR(H/V)54(B/B+)/400 JR(H/V)54(B/B+)/600 JR(H/V)54(B/B+)/1000 JR(H/V)54(B/B+)/2000 JR(H/V)54(B/B+)/3000 JR(H/V)54(B/B+)/3600 JR(H/V)54(B/B+)/4200 JR(H/V)54(B/B+)/6000 JR(H/V)54(B/B+)/

18 Configuration JAKKA Heat recovery units JR(H/V)54(B/B+) Note: The configurations mentioned above (A to D) are not relevant for models JR(H/V)54(B/B+)/6000 and For more information please contact the manufacturer. We reserve the right to introduce alternation both in design and technical data without prior notice due to continued product development. 17

19 JAKKA Heat recovery units JR(H/V)54(B/B+) Control FAN CONTROL - Only fan speed control (two controls per unit) - Bypass valve operates automatically, according to signals T1 and T2. - The pre-heater turns on automatically on signal for freezing. Speed controllers REM-2,5 N - up to 2,5A REM-5 - up to 5A REM-10 - up to 10A S&P COM-3 (3V switch) Frequency inverter SINUS N 1,5-1,8kW - up to 8A SINUS M 1,5kW - up to 4A SINUS N 2,2-3,0KW - up to 12A SINUS M 2,2kW - up to 6A REM -2,5N REM-5 and REM-10 S&P COM-3 SINUS N / SINUS M 18

20 Smart JAKKA Heat recovery units JR(H/V)54(B/B+) HIG-2 (dodatak za Smart) - Adjustable humidistat enables the automatic ON/OFF operation of an extract fan by monitoring the relative humidity level. Adjustable RH level 40-90%, and adjustable timer. - Bypass valve operates automatically, according to signals T1 and T2. - The pre-heater turns on automatically on signal for freezing. SQA (dodatak za Smart) - Air quality sensor with integrated adjustable timer (1-25min). The unit allows to se a level of polution of enviroment, when the fan turns on and duration of the operation period. - Bypass valve operates automatically, according to signals T1 and T2. - The pre-heater turns on automatically on signal for freezing. HIG-2 controller SQA controller 19

21 JAKKA Heat recovery units JR(H/V)54(B/B+) Installation and accessories 20

22 JAKKA Heat recovery units JR(H/V)54(B/B+) Heat recovery unit JR(H/V)54(B/B+) with eficinecy up to 65%. 21

23 JAK-KA GROUP - SRBIJA adresa: Bulevar Zorana Đinđića Novi Beograd, Srbija telefon: +381 (0) faks: +381 (0) web: jakkagroup@jakkagroup.com JAK-KA GROUP - CRNA GORA adresa: V Crnogorske brigade Igalo, Crna Gora telefon: +382 (0) faks: +382 (0) mobilni: +382 (0) web: technoclima-mare@t-com.me

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL UT REC - R HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL 1 CONTENTS GENERAL FEATURES... 3 Scope of the unit... 3 Available configurations... 3 Description of the components...

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

AIR HANDLING COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

AIR HANDLING COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING HANDING COMMERCIA UIDINGS A guide to our Air Handling Units, including our unique product range, consultancy service and accessories. INNOATIE ENTIATION & HEATING In Partnership with www.pricetwa.co.uk

More information

Crna Gora Cjenovnik 1. SEPTEMBAR

Crna Gora Cjenovnik 1. SEPTEMBAR Crna Gora Cjenovnik 1. SEPTEMBAR 2015. WWW.MAZDA.CO.ME Mazda2 (5 vrata) Mazda2 G75 Emotion 55 / 75 5 brzina 11.390 Mazda2 G75 Challenge 55 / 75 5 brzina 11.890 Mazda2 G90 Challenge 66 / 90 5 brzina 12.390

More information

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control Product Data A12479 NOTE: Evolutionr Connext Control compatible with Evolutionr rated equipment only. US Patents: Carrierr U.S.

More information

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range CI/SfB (57.7) 1st Edition from Vent-Axia Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range Energy Recovery Ventilation (ERV) Range Building on the success of the Sentinel Totus 2 range

More information

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599 EN 599-604 AKOR-HR 14/1/08 13:01 Página 599 HIGH EFFICIENCY HEAT RECOVERY UNIT AKOR-HR NEW Heat Recovery unit with casing manufactured from expanded polypropylene. Outlet and inlet duct conectors Ø150.

More information

Swimming Pool CSR2 Heat Recovery Equipment

Swimming Pool CSR2 Heat Recovery Equipment Swimming Pool CSR2 Heat Recovery Equipment LIFETIME WARRANTY OVER 90% HEAT RECOVERY LOW CARBON British manufacturing at its best EcoAir Box is a trademark of IPT +44 (01527) 492770 www.ecoairbox.co.uk

More information

Ducted medium static pressure monosplit DC Inverter

Ducted medium static pressure monosplit DC Inverter +VAV (Variable Air Volume) Ducted medium static pressure monosplit Unique solutions 20 19 22 For 18-24-30-36 23 24 18 A ++ RC08W 2016 Ducted medium static pressure monosplit FUNCTIONS > Ducted line available

More information

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

HERU 90 LP EC HERU 90 LP EC

HERU 90 LP EC HERU 90 LP EC HERU 90 LP EC HERU 90 LP EC Energy recovery unit with low profile and side connections. Designed for supply and exhaust air ventilation with energy recovery (FTX). Suitable for installation in homes, offices

More information

Accessories. Series REC

Accessories. Series REC Accessories Series REC 5-7-9 ACCESSORIES REC Series RBA BAF RBE CV3 PC3 SRE PSD CSA GIU TPA O. REC 5 REC 5-6 - 5BT11 5BT6 1CO71 1CO73 1SE96 5PR 1KR6 5SU137 5TE1 REC 5-12 5BT12 5BT122 5BT121 1CO71 1CO73

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS HRE-TOP EC Non-residential ventilator unit ith dual flo and high

More information

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series False-ceiling models CADB/T-HE 4 to 33 Heat Recovery Compact heat recovery unit with high-efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL SYSTXCCITC01---B Infinityr System Control Product Data A11577 NOTE: Infinityr System Control compatible with Infinityr rated indoor equipment only. US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr

More information

Product Data. SYSTXBBECC01-B Evolutionr Connext Control INDUSTRY LEADING FEATURES/BENEFITS. EVOLUTION r CONNEX t CONTROL

Product Data. SYSTXBBECC01-B Evolutionr Connext Control INDUSTRY LEADING FEATURES/BENEFITS. EVOLUTION r CONNEX t CONTROL SYSTXBBECC01-B Evolutionr Connext Control Product Data A12479 NOTE: Evolutionr Connext Control compatible with Evolutionr rated indoor equipment only. US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr

More information

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room RIRS V EKO Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room Common characteristics: Efficient low-noise

More information

Prepared By : Checked By : Approved By : Page 1 out of 6

Prepared By : Checked By : Approved By : Page 1 out of 6 Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box

More information

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:

More information

Contents. Contents SYSTEM SYSTEM SYSTEM

Contents. Contents SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM Contents Contents Lineup & Feature - Outdoor Units One Outdoor Unit, Multiple Indoor Units Twin BLDC Compressor Sine Wave Controller Current Wave Torque Ripple Current Wave Torque

More information

SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT

SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT 136 SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT Extraction kits for testing centres for cars, light commercial vehicles and heavy vehicles with manual or automatic return system Equipments

More information

delivering pure air for 60 years in all weathers, and improv all the while DLSE + VAV System

delivering pure air for 60 years in all weathers, and improv all the while DLSE + VAV System ! ential, Airwell Resid delivering pure air for 60 years in all weathers, ing and improv all the while DLSE + VAV System 19 20 22 23 24 18 2016 Room by room control [ ZONE CONTROLLER ] q The zone controller

More information

CEILING CONCEALED LOSSNAY LGH-25RX3

CEILING CONCEALED LOSSNAY LGH-25RX3 VOLUME SIGN Control signal Heat recovery system Heat recovery module material Cladding Heat insulating material Motor Blower Filter material Operating environment (Supply air) Functions Weight Serial single

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

Product Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL

Product Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL SYSTXBBUIZ01 -D Evolutiont Zone Control Product Data A10287 NOTE: Evolutiont Zone Control compatible with Evolution rated indoor equipment only. EVOLUTION t ZONE CONTROL Bryantr specializes in creating

More information

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014 FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS COMMERCIAL AIR CONDITIONERS SDV4 2014 AIR CONDITIONING 1 WELCOME TO THE WORLD OF SINCLAIR AIR CONDITIONERS Company operation

More information

CEILING CONCEALED LOSSNAY LGH-80RX3

CEILING CONCEALED LOSSNAY LGH-80RX3 LGH-8RX3 VOLUME SIGN Control signal Heat recovery system Heat recovery module material Cladding Heat insulating material Motor Blower Filter material Operating environment (Supply air) Functions Weight

More information

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHPHX Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. Cooling Capacity: 6,4 97,4 next dx C rcgroupairconditioning R410 E C UP FLOW DOWN FLOW MIN FETURES

More information

CEILING CONCEALED LOSSNAY LGH-50RX3

CEILING CONCEALED LOSSNAY LGH-50RX3 LGH-RX3 VOLUME SIGN Control signal Heat recovery system Heat recovery module material Cladding Heat insulating material Motor Blower Filter material Operating environment (Supply air) Functions Weight

More information

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW: VHR Void Mounted Heat Recovery Units TM.72 W/I/s TOTAL SFP Typical General: Units shall be manufactured from high quality galvanized sheet steel with stainless steel drain trays, acoustic, non-hygroscopic

More information

Everest XV. ErP. High Efficiency HRV Fan Unit READY

Everest XV. ErP. High Efficiency HRV Fan Unit READY High Efficiency HRV Fan Unit ErP READY Field of application Installation Advantages Description Range Technical details Aeraulic and electrical details Acoustic specifications Aldes Smart Control system

More information

Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL

Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL SYSTXCCUIZ01-- V Infinityt Zone Control Product Data A07258 NOTE: Infinityt Zone Control compatible with Infinity rated indoor equipment only. INFINITY t ZONE CONTROL Carrierr specializes in creating a

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

Achieve Up To 200% Greater Efficiency And Better Air Flow Performance With GE ECM Technology

Achieve Up To 200% Greater Efficiency And Better Air Flow Performance With GE ECM Technology Achieve Up To 200% Greater Efficiency And Better Air Flow Performance With GE ECM Technology GE ECM 2.3 ECM X13 What's an ECM? The highest efficiency motor there is! essentially a DC Motor Without mechanical

More information

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm] ACME SCREW LINEAR ACTUATOR ATL 02 Stroke Actuator with DC motor La =Lc + Stroke Lc T OVERALL DIMENSIONS Rear bracket SP Pin Actuator with or 3-phase motor Capacitor Stroke end reed switches FCM Motor cable

More information

Crna Gora Cjenovnik. 15. JANUAR

Crna Gora Cjenovnik. 15. JANUAR Crna Gora Cjenovnik 15. JANUAR 2017. www.mazda.co.me Mazda2 (5 vrata) Mazda2 G75 Emotion 55 / 75 5 brzina 11.590 Mazda2 G75 Challenge 55 / 75 5 brzina 12.090 Mazda2 G75 TAKUMI 55 / 75 5 brzina 13.590 Mazda2

More information

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems. All Seasons CLIMATE COMFORT Heating 3. SERVICE TOOLS 3.2. Inverter checker RSUK09-17 Air Conditioning Applied Systems Refrigeration 3.2. Inverter checker RSUK09-17: index 1. Outlook 2. How to connect?

More information

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS LENGTH

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS LENGTH BALL SCREW LINEAR ACTUATOR BSA 2 OVERALL DIMENSIONS Stroke La =Lc + Stroke Lc T Capacitor Rear bracket Pin SP Standard head with threaded hollow bore BA depth 7 Stroke end reed switches FCM (brake motor)

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

RECTANGULAR EXTRACT FANS

RECTANGULAR EXTRACT FANS RECTANGULAR EXTRACT FANS Wide duty range 0.05m 3 /sec to 3.2m 3 /sec Horizontal or vertical mounting Quick and easy to install VES EXTRACT FANS part of a complete range of innovative, flexible products

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

8/S3 8/S1 AIR CURTAINS AIR CURTAINS SONATA, SONATA-V SONATA, SONATA-V. v 3.1 (en) v 1.0 (en) Design changes reserved

8/S3 8/S1 AIR CURTAINS AIR CURTAINS SONATA, SONATA-V SONATA, SONATA-V. v 3.1 (en) v 1.0 (en)  Design changes reserved 8/S3 8/S1 v 3.1 (en) v 1.0 (en) AIR CURTAINS SONATA, SONATA-V AIR CURTAINS SONATA, SONATA-V PB 4 www.klimaoprema.hr 1 425 AIR CURTAIN SONATA TABLE OF CONTENTS Air curtain Sonata No 4273 Technical characteristics

More information

AIR-AIR ENERGY CONSERVATION MODULE

AIR-AIR ENERGY CONSERVATION MODULE AIR-AIR ENERGY CONSERVATION MODULE BC-ECW SERIES INDOOR/OUTDOOR INSTALLATION MANUFACTURED BY TABLE OF CONTENTS BC-ECW - Description...3 Components and fabrication details...3-4 Frost prevention & selection

More information

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 HRH High efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4.3 m³/h The HRH units have been designed for non-residential applications for which a forced and

More information

CH5000 Heat Recovery Ventilator

CH5000 Heat Recovery Ventilator ADVANCED COMMERCIAL Heat Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 3500-5500 CFM CASING Double-wall cabinet White exterior paint, 22-gauge galvanized steel -gauge

More information

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw DRAFT Ducted Three Phase Packaged Air Conditioners Technical Data 96 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil OPTION TZT-71 Controller & Digital Scroll Compressor for close

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X Date: 08.06.2018 Price: 13121 EUR without VAT, W Vilnius Air handling unit model: VERSO-CF-30-2.6-H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X TECHNICAL SPECIFICATION AHU size 30 Typology NRVU BVU of HRS other

More information

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation

More information

YCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO

YCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO YCZ RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO q Multi line available in four capacities from 5.2 up to 10.5 kw. q DC Inverter and sine wave compressor drive technology. q Match with high wall, ducted,

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A Superior Performance in Extreme Temperature Submittal Data: 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Fan coil unit NBS 100/150

Fan coil unit NBS 100/150 Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3

More information

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes Cooling capacity: Heating capacity: 92,1 to 179,9 kw 69, to 148,7 kw Heating and dehumidification of covered pools Optimized energy consumption Electronic control Description Principle schemes The range

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

Product Brochure 2018

Product Brochure 2018 Product Brochure 2018 2018 Brand Story - 2 - HEALTH Air Filter COMFORT Auto mode heating or cooling. and other materials. Wi-Fi Control Compatible to the Internet Evaporator self-cleaning ENERGY DRED Soft

More information

Fault Codes. J control

Fault Codes. J control J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 Enter unit inspection mode by pushing the UP and DOWN buttons simultaneously for two seconds. Ensure that the

More information

A I R C O M P R E S S O R S R O L L A I R E

A I R C O M P R E S S O R S R O L L A I R E A I R C O M P R E S S O R S ROLLAIR 75-100-125E E F F I C I E N C Y R E L I A B I L I T Y Superior quality & Performance The modern ROLLAIR compressor is the result of more than 30 years of continuous

More information

Comfort Door Air Curtains. Li, Li EC.

Comfort Door Air Curtains. Li, Li EC. Comfort Door Air Curtains Li, Li EC www.stavoklima.eu Door Air Curtains Li Content Content: Selection of the air curtain...page 4 Air Curtains Li with static and dynamic advertising panel...page 5 Technical

More information

Goedhart FC38. Standard air coolers Cu/Al. R404A - Coolants. engineering for a better world. GEA Heat Exchangers. Goedhart FC38S.

Goedhart FC38. Standard air coolers Cu/Al. R404A - Coolants. engineering for a better world. GEA Heat Exchangers. Goedhart FC38S. Goedhart FC38S Goedhart FC38D Goedhart FC38L Goedhart FC38 Standard air coolers Cu/Al R404A - Coolants engineering for a better world GEA Heat Exchangers Paragraph Styles Goedhart FC38 The range GEA Goedhart

More information

Heat Exchangers. Evaporator Catalogue

Heat Exchangers. Evaporator Catalogue Heat Exchangers Evaporator Catalogue Version 30: January 2015 Heat Exchangers Thermocoil Catalogue V30 2015 Evaporators Page 2 INDEX EVAPORATORS PAGE Evaporator Design and Info 4 Quick Find List (Sorted

More information

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS BSA 10 AC motor Stroke La =Lc + Stroke Lc Capacitor T Rear bracket SP Pin Standard head with threaded hollow bore BA 80 depth 17 Stroke end reed switches FCM

More information

A20 A20. Aluminium heat exchanger 398SAE004EN00

A20 A20. Aluminium heat exchanger 398SAE004EN00 Aluminium heat exchanger A A 98SAEEN Before using the heat exchanger, carefully read the document entitled GENERAL INSTRUCTIONS FOR HEAT EXCHANGER USE. 98SAEEN - --7 A V-V Dimensions ± L MAX C 8,, H ±

More information

Models: 12 and 18. Models: 24 to 60

Models: 12 and 18. Models: 24 to 60 SPLIT CASSETTE TYPE MUCSR-H8 Series SCOP 4.0 Models: 12 and 18 RG57B2/BGE Included (CL 94 982) Models: 24 to 60 Design 360 Thanks to the 360 panel design, the air is more evenly distributed. Drainage pump

More information

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

Split-Sky Air FDYP-B7 Concealed Ceiling Unit TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the

More information

TECHNICAL MANUAL SOFFIO Ducted units

TECHNICAL MANUAL SOFFIO Ducted units TECHNICAL MANUAL SOFFIO Ducted units Page 1 INDEX 1-INTRODUCTION... 4 2-OPERATING LIMITS... 4 3- KEY TO READING CODES... 5 4-TECHNICAL SPECS... 6 5-TECHNICAL DATA (AC motors)... 7 5.1-Unit 2 pipes with

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

ECONET Fault and error manual

ECONET Fault and error manual Fault and error manual March 2009 Contents Basic data to get started...3 A Alarms 1. Ice alarm, GT 42...4 2. Frost alarm, GT 41...4 3. Pump alarm, P 40...5 4. Pressure alarm, GP 40...5 5. Liquid, temperature

More information

Armatures and Heaters

Armatures and Heaters Armatures and Heaters - more than functional I n d e K l i m a M i l j ø A / S IndeKlimaMiljø A/S, or just, takes advantage in many years of experience as well internally as with our partners and suppliers

More information

Starcool Reefer Parts Service Manual, CIM6, Spare part catalog Short Form manual, CIM6, ES. Back plate, evaporator

Starcool Reefer Parts Service Manual, CIM6, Spare part catalog Short Form manual, CIM6, ES. Back plate, evaporator Starcool Reefer Parts Service manual, CIM5-UK Service manual, CIM6-UK Service manual, CIM5-JP Service manual, CIM6-ES Service manual, CIM6-CN Service Manual, CIM6, Spare part catalog Short Form manual,

More information

List price 2012 USD A Service manual, CA-UK B Service manual, CIM5-UK C Service manual, CIM6-UK 29.

List price 2012 USD A Service manual, CA-UK B Service manual, CIM5-UK C Service manual, CIM6-UK 29. Item # Description List price 2012 USD 810800A Service manual, CA-UK 22.22 810900B Service manual, CIM5-UK 29.63 810900C Service manual, CIM6-UK 29.63 810901B Service manual, CIM5-JP 29.63 810902C Service

More information

CATÁLOGO TÉCNICO COMERCIAL

CATÁLOGO TÉCNICO COMERCIAL CATÁLOGO TÉCNICO COMERCIAL ENFRIADORAS DE AGUA CONDENSADAS POR AIRE Series LCAEX De 350 a 1600 Kw. Compresor de tornillo R-134A Index Identification code Identification code and index... pag. 2 General

More information

Rotary Heat Wheel (Rotary Enthalpy Wheel)

Rotary Heat Wheel (Rotary Enthalpy Wheel) Rotary Heat Wheel (Rotary Enthalpy Wheel) Introduction SAIVER cooperates with Heatex a leading Sweden Heat Exchanger Specialist to provide a compact and high efficiency rotary heat wheel for our worldwide

More information

ELLECI RASPRODAJA 2018

ELLECI RASPRODAJA 2018 ELLECI RASPRODAJA 2018 I T P I R100% MADE IN ITALY CE TIFICATE Garantito Warranty 20 Anni Years Garantito Warranty 20 Anni Years DOGMA 100 SLIM BEST 480 VALUE 130 STD Dimenzija sudopera (mm) 945x505

More information

climaciat airtech Air handling units Air handling for all applications Climaciat Airtech The technological choice Performing to new standards

climaciat airtech Air handling units Air handling for all applications Climaciat Airtech The technological choice Performing to new standards Climaciat Airtech The technological choice Characteristics Casing strength Casing air leakage Filter bypass leakage Thermal transmittance Thermal bridge factor Class D2 L1-L2 F9 T2 TB2 Air flow: 1 000

More information

TRT SYSTEM. Product Description

TRT SYSTEM. Product Description TRT SYSTEM Product Description The TRT is a machine that exploits the flow and the pressure of the furnace output gas to produce electric energy. Through a system of regulation managed by PLC it maintains

More information

MIDDLE LOAD RELAY FOR SMART J/B

MIDDLE LOAD RELAY FOR SMART J/B MIDDLE LOAD RELAY FOR SMART J/B CN-M RELAYS (ACNM) New Compliance with RoHS Directive FEATURES. Best space savings in its class.. Compact and high-capacity A load switching.. Full line up (High heat-resistant

More information

Air Conditioning Solutions for Defense Applications. Cool Solutions for Hot Problems

Air Conditioning Solutions for Defense Applications. Cool Solutions for Hot Problems Air Conditioning Solutions for Defense Applications Cool Solutions for Hot Problems A i r C o n d i t i o n i n g a n d N B C S y s t e m s Introduction The field of Air Conditioning for ground defense

More information

8. DISASSEMBLY ILLUSTRATION & PARTS LIST

8. DISASSEMBLY ILLUSTRATION & PARTS LIST 8. DISASSEMBLY ILLUSTRATION & PARTS LIST 8. DISASSEMBLY ILLUSTRATION & PARTS LIST 8-1 OUTDOOR UNIT Model : AJ*144LALH ( : & A) AJ*126LALH ( : & A) 1 37 38 32 33 3 34 12 4 2 21 5 13 8 15 9 30 28 6 29 11

More information

PGK Rectangular duct coolers for cooled water

PGK Rectangular duct coolers for cooled water Rectangular duct coolers for cooled water Rectangular duct coolers for cooled water The with rectangular duct connection uses chilled water as the energy carrier and is used for cooling the ventilation

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

Heat recovery units type GTDHR

Heat recovery units type GTDHR GTDHR Double flux - 4 m3/h AC 23V type GTDHR Double flux heat recovery unit high efficiency 9%. The range consists of 5 sizes and 6 types for air flow from up to 4 m³/h. Application Ventilation and heat

More information

Industrial air coolers for cooling & freezing applications Cu/Al

Industrial air coolers for cooling & freezing applications Cu/Al Goedhart VCI Industrial air coolers for cooling & freezing applications Cu/Al R404A - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VCI The extensive range Goedhart VCI single discharge

More information

application guide axial condensing units

application guide axial condensing units application guide axial condensing units 17 English/07-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectations WARNING: Read this manual before installation,

More information

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY TOP QUALITY SOLUTIONS FOR YOUR LABORATORY Distributed By Polypropylene Ductless Fume Hood Easily dissembled back wall Tempered glass sliding front window Monitor displays fan s total operation time, for

More information

M443AL, 1U 19 3 way Power Strip

M443AL, 1U 19 3 way Power Strip M443AL, 1U 19 3 way Power Strip M443AL, 3 way Power Strip Specification M443AL 3 ways 16A plug DIN49441 Single 4000Watt 16A 1.5mm2 (16AWG) 16A Miniature Circuit Breaker Mounting Length Case Length 3x1.5mm2

More information

Engineering Data Book

Engineering Data Book 40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142 3/2-way Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2 W 142 = 24 V DC, 4.2 W 152 = 24 V AC, 7/4 VA 156 = 115 V AC,

More information

Engineering Data Book

Engineering Data Book 40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

PACK SMART RIDE OVER STANDARD PERFORMANCE

PACK SMART RIDE OVER STANDARD PERFORMANCE PACK SMART RIDE OVER STANDARD PERFORMANCE MADE IN ITALY PACK SMART RIDING OVER STANDARD PERFORMANCE WHEREVER RELIABILITY AND EFFICIENCY ARE REQUESTED Pack Smart is the best expression of integration and

More information

High Wall Type ( 2 Series )

High Wall Type ( 2 Series ) Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle

More information

vortice.com COMMERCIAL VENTILATION VORT NGR EVO RANGE High efficiency heat recovery units equipped with static exchangers NEW

vortice.com COMMERCIAL VENTILATION VORT NGR EVO RANGE High efficiency heat recovery units equipped with static exchangers NEW vortice.com COMMERCIAL VENTILATION VORT NGR EVO RANGE High efficiency heat recovery units equipped with static exchangers NEW B Vortice main company s philosophy is the concept that air is our life. Our

More information

Ductless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018

Ductless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018 Higher Comfort, Haier Living 2018 MRV-S (Mini VRF) Product Brochure rev 01012018 Ductless HAIER MRV MILESTONES MRV-S KEY FEATURES Haier is one of the leading producers of HVAC products, having the capacity

More information

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10)

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10) APPLICATION NOTES Industrial Wall Control (IWC0) (English) (IWC0) The Breezair Industrial Wall Control (IWC0) is designed to provide both local and external Evaporative Air cooler control for all Breezair

More information