M443AL, 1U 19 3 way Power Strip
|
|
- Stephen Jennings
- 6 years ago
- Views:
Transcription
1 M443AL, 1U 19 3 way Power Strip M443AL, 3 way Power Strip Specification M443AL 3 ways 16A plug DIN49441 Single 4000Watt 16A 1.5mm2 (16AWG) 16A Miniature Circuit Breaker Mounting Length Case Length 3x1.5mm2 1U 482.6(19")x44.4x44.4 (mm.) 465mm 430.5mm. Frontal installation
2 M446AL, 1U 19 6 way Power Strip M446AL, 1U 19 6 way Power Strip Specification AUE2250D3-06AHDGMB 6 ways 16A plug DIN49441 Single 4000Watt 16A 1.5mm2 (16AWG) 16A Miniature Circuit Breaker Mounting Length Case Length 3x1.5mm2 1U 482.6(19")x44.4x44.4 (mm.) 465mm 430.5mm. Frontal installation
3 M446STD, 1U 19 6 way Power Strip M446STD, 1U 19 6 way Power Strip Specification AUE2250D3-06AHDCMB 6 ways 16A plug DIN49442 Single 4000Watt 16A 1.5mm2 (16AWG) ON/OFF 16A lighted ON/OFF switch Mounting Length Case Length 3x1.5mm2 1U 482.6(19")x44.4x44.4 (mm.) 465mm 430.5mm. Frontal installation
4 M449AL, 2U 19 9 way Power Strip M449AL, 2U 19 9 way Power Strip Specification AUE2260D3-09AHDGMB 9 ways 16A plug DIN49441 Single 4000Watt 16A Combined Copper 16A Miniature Circuit Breaker Mounting Length Case Length 3x1.5mm2 2U 482.6(19")x44.4x88.8 (mm.) 465mm 430.5mm. Frontal installation
5 M446AL SP, 1U 19 6 way Power Strip M446AL SP, 1U 19 6 way Power Strip Specification AUE2250D3-06AHDCHB 6 ways 16A plug DIN49441 Single 4000Watt 16A 1.5mm2 (16AWG) Surge 16A lighted ON/OFF switch Mounting Length Case Length 3x1.5mm2 1U 482.6(19")x44.4x44.4 (mm.) 465mm 430.5mm. Frontal installation
6 M446AL UK, 1.4U 19 6 way Power Strip M446AL UK, 1.4U 19 6 way Power Strip Specification AUE2220B1-06AHBCMB BS1363 UK type Socket 6 ways 13A plug BS1363 Single 4000Watt 13A 1.5mm2 (16AWG) ON/OFF 16A lighted ON/OFF switch Mounting Length Case Length 3x1.5mm2 1.4U 482.6(19")x44.4x62 (mm.) 465mm 430.5mm. Frontal installation
7 M44 6AL IEC AMP, 1U 19 6 way Power Strip M44 6AL IEC AMP, 1U 19 6 way Power Strip Specification AUE2250C2-06AHEGDB IEC320 C13 6 ways IEC60309 plug (16A 2P+E) Single 4000Watt 13A 1.5mm2 (16AWG) Monitor Function 16A Miniature Circuit Breaker 32A Amp. Meter Mounting Length Case Length 3x1.5mm2 1U 482.6(19")x44.4x44.44 (mm.) 465mm 430.5mm. Frontal installation
8 M44 24AL IEC, 1.4U 20+4 way Power Strip M44 24AL IEC, 1.4U 20+4 WAY POWER STRIP SPECIFICATION AUE2220H1-24AVFN IEC320 C13, IEC320 C19 20 ways:c ways:c19 IEC60309 plug (32A 2P+E) Double 8000Watt 32A 2.5mm2 Direct connection to system Monitor Function Direct 32A Amp. Meter Mounting Length Case Length 3x6mm2 1.4U 1346x44.4x62mm 1336mm 1338mm Inverse installation
9 M44 24AL IEC MCB, 1.4U 20+4 way Power Strip M44 24AL IEC MCB, 1.4U 20+4 way Power Strip Specification AUE2220H1-24AVFTDB IEC320 C13, IEC320 C19 20 ways:c ways:c19 IEC60309 plug (32A 2P+E) Double 8000Watt 32A 1.5mm2 per circuit Monitor Function 2ea. 16A Miniature Circuit Breaker 2ea. 32A Amp. Meter Mounting Length Case Length 3x6mm2 1.4U 1648x44.4x62mm 1620mm 1592mm Inverse installation
10 M44 20AL IEC MONITOR, 2U 20 way Power Strip M44 20AL IEC MONITOR, 2U 20 way Power Strip Specification NA412H2022 IEC320 C13, IEC320 C19 16 ways:c ways:c19 IEC60309 plug (32A 2P+E) Double 8000Watt 32A 2.5mm2 Monitor Function Settings Alarm Function Alarm Type Current Consumption Measurement Log record User Management Turn off Accessing Method 2ea. 16A Miniature Circuit Breaker Total current Operating Status of PDU Temperature/Humidity state Smoke state Waterlogging state Door open state Limiting range of total load current Limiting range of temperature and humidity Total load current exceeds the limiting value System goes wrong Smoke Waterlogging Door openning On PDU:Flashing indicator and buzzer Web interface: flashing indicator and buzzer in PC alarms Automatic sending to system administrator SNMP sends alarm information Automatic alarm with wireless telecommunications Automatic record the current consumption in unit time Record and save the operating information of NMP, provide the query and outlet of records Set users's right Remotely soft turn off Web, access through IE SNMP (V1/V2C/V3) access to control through standard network working station Telnet, SSH, Access to control through command controlling station
11 M44 20AL IEC MONITOR, 2U 20 way Power Strip 3x6mm3 2U 1744x88.8x44.4mm Inverse installation
12 M44 20AL IEC SMART, 2U 20 way Power Strip M44 20AL IEC SMART, 2U 20 way Power Strip Specification ND412H2022 IEC320 C13, IEC320 C19 16 ways:c ways:c19 IEC60309 plug (32A 2P+E) Double 8000Watt 32A 2.5mm2 Monitor Function Settings Alarm Function Alarm Type Current Consumption Measurement Log record User Management Turn off Accessing Method 2ea. 16A Miniature Circuit Breaker Total current Load current of each outlet On/off state of each outlet Operating Status of PDU Temperature/Humidity state Smoke state Waterlogging state Door open state Server Operating Status Limiting range of total load current Limiting range of temperature and humidity Limiting range of the load current of each outlet Total load current exceeds the limiting value Load currrent of individual outlet exceed the limiting value Individual outlet goes wrong System goes wrong Smoke Waterlogging Door openning On PDU:Flashing indicator and buzzer Web interface: flashing indicator and buzzer in PC alarms Automatic sending to system administrator SNMP sends alarm information Automatic alarm with wireless telecommunications Automatic record the current consumption in unit time Record and save the operating information of NMP, provide the query and outlet of records Set users's right Remotely soft turn off Web, access through IE SNMP (V1/V2C/V3) access to control through standard network working station Telnet, SSH, Access to control through command controlling station
13 M44 20AL IEC SMART, 2U 20 way Power Strip 3x6mm3 2U 1744x88.8x44.4mm Inverse installation
14 EM GRP319A, 1U 19 3 way Power Strip EM GRP319A, 1U 19 3 way Power Strip Specification EM GRP319A 3 way 16A plug DIN49442 Single 4000Watt 16A 1.5mm2 (16AWG) ON/OFF 16A lighted ON/OFF switch 3x1.5mm2 1U 482.6(19")x44.4x44.44 (mm.) PVC Profile Frontal installation
15 EM GRP619A, 1U 19 6 way Power Strip EM GRP619A, 1U 19 6 way Power Strip Specification EM GRP619A 6 way 16A plug DIN49442 Single 4000Watt 16A 1.5mm2 (16AWG) ON/OFF 16A lighted ON/OFF switch 3x1.5mm2 1U 482.6(19")x44.4x44.44 (mm.) PVC Profile Frontal installation
16 M441847ALD, 1.4U 18 way Power Strip M441847ALD, 1.4U 18 way Power Strip Specification M441847ALD 18 way No plug Double (9+9) 8000Watt 32A 4mm2 2ea. 16A Miniature Circuit Breaker Aluminium Grey No cable 1.4U Length=2000mm. Bottom Inverse or Frontal installation
17 M441842ALD, 1.4U 18 way Power Strip M441842ALD, 1.4U 18 way Power Strip Specification M441842ALD 18 way No plug Double (9+9) 8000Watt 32A 4mm2 2ea. 16A Miniature Circuit Breaker Aluminium Grey No cable 1.4U Length=1800mm. Bottom Inverse or Frontal installation
18 M441842ALD, 1.4U 18 way Power Strip M442442ALD, 1.4U 24 way Power Strip Specification M442442ALD 24 way No plug Double (12+12) 8000Watt 32A 4mm2 2ea. 16A Miniature Circuit Breaker Aluminium Grey No cable 1.4U Length=1800mm. Bottom Inverse or Frontal installation
19 M441836ALD, 1.4U 18 way Power Strip M441836ALD, 1.4U 18 way Power Strip Specification M441836ALD 18 way No plug Double (9+9) 8000Watt 32A 4mm2 2ea. 16A Miniature Circuit Breaker Aluminium Grey No cable 1.4U Length=1550mm. Bottom Inverse or Frontal installation
20 M441226ALD, 1.4U 12 way Power Strip M441226ALD, 1.4U 12 way Power Strip Specification M441226ALD 12 way No plug Double (6+6) 8000Watt 32A 4mm2 2ea. 16A Miniature Circuit Breaker Aluminium Grey No cable 1.4U Length=1100mm. Bottom Inverse or Frontal installation
21 M446ALD, 1U 6 way Power Strip M446ALD, 1U 6 way Power Strip Specification M446ALD 6 way 16A plug DIN49441 Double (3+3) 4000Watt 16A 1.5mm2 (16AWG) 16A Miniature Circuit Breaker Mounting Length Case Length 3x1.5mm2 1U 482.6(19")x44.4x44.4 (mm.) 465mm 430.5mm. Frontal installation
SNMP dedicated to ORVALDI Solar Infini
SNMP dedicated to ORVALDI Solar Infini User s Manual Management Software for Solar Inverter Table of Contents 1. 2. 3. Overview...1 1.1 Introduction...1 1.2 Features...1 1.3 Overlook...1 1.4 Installation
More informationUSER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA
USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA Important Safety Information Before installing UPS Endure 500VA/750VA/1000VA/2000VA, please read the operating instructions carefully.
More informationLINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL
LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL Important Safety Information Before installing UPS EN-1000/ EN-2000, please read the operating instructions carefully. Special attention
More information19 SOUNDproof Cabinets / W:750mm D:1130mm
19 SOUNDproof Cabinets / W:750mm D:1130mm SOUNDproof Free Standing Cabinets General Concept; SOUNDproof Free Standing cabinets are designed to perform for the absorbtion of the created noice from the active
More informationTemperature Probes. Operating Range: -40 F to 140 F -40 C to 60 C
Temperature s Standard Temperature The Standard Temperature is constructed with 24 AWG 2 conductor cable which is PVC jacketed. A vinyl cap sealed with epoxy protects the sensor on this versatile, accurate
More informationRA19 Cable Management, 5 hooks
RA19 Cable Management, 5 hooks Standards of reference and applications EIA19 Installation Features Store at -0 to +70 C Install at -0 to +50 C Operate at : -20 to +60 C Fitting : designed for LAN 1 unit
More informationTechnical data sheets
GE Digital Energy Technical data sheets Digital Energy Uninterruptible Power Supply Series UPS 6-10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41
More informationRack Power Distribution & Rack Systems Worldwide
Rack Power Distribution & Rack Systems Worldwide Introduction TM APC TM by Schneider Electric offers a wide array of standardized Rack Power Distribution Units (PDUs) designed to increase manageability
More informationSY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath
Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical
More informationIntelligent DC UPS Module
Intelligent DC UPS Module 12V/9~36V DC Input, 12V DC Output Uninterruptible Power Supply Module with Diagnostics VESA or VESA mounting 9-36V input through terminal or power jack, or 12V through power jack
More informationModel ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase
Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible
More informationUp to 98% efficient under full load Similar runtimes to the previous 3u model
New Model replacing the PS6003rm3uXL Up to 98% efficient under full load Similar runtimes to the previous 3u model @ 1,000 800 600 400 200 : ' 100 e 80 " E 60 ~ " "' 40 20 10 8 500 1,000 1,500 2,000 2,500
More informationRFQ-YEM Solar Lighting System for UNDP
AMENDMENT 1 for RFQ-YEM-0076-2016 Solar Lighting System for UNDP This Amendment is issued after the Pre-bid meeting and site visit arranged as mentioned on the RFQ docs and the results as following: To
More informationUSER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER
USER'S GUIDE WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER LEN.MAN.STA.145 Rev.5.00/2010 CONTENTS 1. SAFETY INSTRUCTIONS 1 2. INTRODUCTION 2 3. FRONT PANEL AND INSIDE
More informationRack power distribution and rack systems worldwide
Rack power distribution and rack systems worldwide apc.com Introduction APC TM by Schneider Electric offers a wide array of standardized Rack Power Distribution Units (PDUs) designed to increase manageability
More informationAurora Single Phase Emergency Lighting Inverters
Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available
More informationSAFEbox IP55 Indoor Wall Mounting CABINETs. W=600mm SAFEbox IP55 Indoor Wall Mounting Cabinets
W=600mm SAFEbox IP55 Indoor Wall Mounting Cabinets SAFEbox IP55 Indoor Wall Mounting Cabinets are designed for industrial applications. Based on EN60529 provided IP55 protection class against dust and
More informationTechnical data sheets
GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company
More informationDIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications
DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry
More informationOnfiniti. 1 Phase UPS
Onfiniti 1 Phase UPS Today's business continuity demands a cost-effective power protection solution, for ensuring Power Continuity and Power Quality with optimal Total Cost of Ownership (TCO). The UPS
More informationSwitches 10AX/16AX. Safety. Easy Operation. Switch Mechanism. Characteristics of Urea Resin. Screwless Terminal (reduces installation work) Features
FLATIMA SERIES Switches 0AX/6AX Way Switch Intermediate Switch Push Button Safety PBT Resin Silver Alloy Contact Superior Arc Resistance and Anti-Deposition Properties Spring with Double Contact Points
More informationgimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy
GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,
More informationUSER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4
USER S MANUAL PowerWalker VFI 1000 / 3000VA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION......... 2 3. SYSTEM DESCRIPTION......... 4 4. CABLE CONNECTION......... 7 5. OPERATION...... 8 6. TROUBLE
More informationINTELLIGENT & BASIC POWER DISTRIBUTION UNITS
INTELLIGENT & BASIC POWER DISTRIBUTION UNITS The Conteg Intelligent & Basic Power product range comprises three different technologies to address the needs of high-density computing users. MONITORED PDU
More informationTyre Health System (THS) Installation Manual
Tyre Health System (THS) Installation Manual Contents 1. TYRE HEALTH SYSTEM (THS) INSTRUCTION... 3 1.1. Prerequisites & Preparations... 3 1.1.1. Preparations:... 3 1.2. General information... 4 1.2.1.
More informationTender Schedule. Sl. No. Particulars Quantity Unit Rate `
Tender Schedule Estimate for Electrical Works at Savalyapuram Branch(18901) Guntur(District). Sl. No. Particulars Quantity Unit Rate ` 1 Wiring for light point/ fan point/ exhaust fan point/ call bell
More information8000mAh Jump Starter User Manual
U3 8000mAh Jump Starter User Manual Web: www.suaoki.com E-mail: support@suaoki.com Thank you for choosing Suaoki. Suaoki U3 is a 3-in-1 device, functioning as a jump starter to boost flat car battery,
More informationProfitronic I. Technical data
Profitronic I Aluminium electronic enclosure for telecommunication and MCR technology Variable length version using profile technology Screw-down fins integrated into sides Different lid versions depending
More informationOn Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual
On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains
More informationMINIATURE CIRCUIT BREAKER
Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V
Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More information+91-8071801149 Goyal Electricals And Electronics http://www.goyalshop.com/ We offer wide range of Electrical & Electronic Products to our clients. We do not compromise on quality and therefore our products
More informationATS - Automatic Transfer Switch. AMF - Automatic Mains Failure. Synchro/Parallel applications like: MPM - Multiple Prime Mover
SICES Srl provides a wide range of smart genset controllers for several applications like: ATS - Automatic Transfer Switch AMF - Automatic Mains Failure Synchro/Parallel applications like: MPM - Multiple
More informationTechnical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality
GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationTECHNICAL DATA MINICUBE A SMART SOLUTION, POWERFUL IN ITS SIMPLICITY
TECHNICAL DATA MINICUBE A SMART SOLUTION, POWERFUL IN ITS SIMPLICITY TURNKEY, COST-EFFICIENT, professional IT infrastructure for server room applications With the adoption of cloud computing, many companies
More informationMotors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB
Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature
More information» Sophisticated» Reliable» Intelligent
PowerGem Pro Series Single and Three Phase Input & Single Phase Output True Online Double Conversion UPS 6kVA 30kVA PowerGem Pro Series» Sophisticated» Reliable» Intelligent VFI The PowerGem Pro is the
More informationGeneral Precautions. Personnel Precautions
USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only
More informationPower Switching Devices
Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier
More informationMay A 15A 15A 15A 10A 15A 10A 15A 10A POWER STRIPS - PROLINK. 5x IEC C13 OUTLETS PDU - 1RU. 5x IEC C13 3x IEC C19 OUTLETS PDU - 1RU
AC Power Strips Prolink - 2017 Update POWER STRIPS - PROLINK ASSEMBLED IN AUSTRALIA. Introducing an expanded range of superior quality PDUs. ProLink PDUs are locally manufactured in Australia with 1.2mm
More informationGENSET PRODUCTS 013 2
GENSET PRODUCTS 2013 TECHNOLOGY IS NOW FOR EVERYONE D 700 COMMUNICATION CAPABILITIES AUTOMATIC MAINS FAILURE UNITS DKG 107 DKG 107 The lowest cost AMF module Factory set timers Adjustable AC low voltage
More informationTender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount
Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable
More informationApplications Profitronic 19 / Profitronic 19U
Applications Profitronic 19 / Profitronic 19U 54 Enclosure in variable length version using profile technology Standard construction or version with connection compartment Optional Polycarbonate transparent
More information19 CLOSE RACK & WALL RACK 19 WALL MOUNT RACK. JK Dynamic Co., Ltd. Tel : Fax :
19 WALL MOUNT RACK º 19" Wall Mount Rack Design three compartment, front, middle and rear. º Material made of electro galvanized sheet steel 1.2mm.thickness, 100% rust-proof and durable. º Mounting vertical
More informationPhoenix Inverter
Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC
More informationEstimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount
Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount 1 2 Writing for light point/ fan point/ exhaust fan point /call bell point with 1.5 sq.mm FR PVC insulated
More information1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems
Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems An additional function allows measuring residual currents in earthed power supplies (TN/TT systems) too.
More information3.2 DOMINO Series... from page c. 126
. Series.......................................................................................... from page c. 6 The System offers a complete range of consumer units and sealed mounted enclosures for
More informationRemote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)
SinusMax Superior engineering Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications. The design criteria have been to produce a true sine wave
More information1-Phase Intelligent ATS
-Phase Intelligent ATS 0V / 208V / 230V Smarter Design Faster Delivery Better Performance Key Benefit Input Switching Locally or Remotely Over IP HTTP Local power input switching is essential, especially
More information22378 / / DRIP STANDS. Device cart. IV Stand for general medicine
Tube diameter 33mm 22410 64 64 100 10 0.28 22410 310 22410 Device cart Tube diameter 33mm Fixed height 1000mm Upper ABS shelf with extended up rims on four sides 390x320mm Pushing handle Basket 300 x 200
More informationData sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN
Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable Cat.6A, x-coded, 8-pole side 1: M12-jack, straight
More informationFused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series
28 Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 281... Blown fuse indication Exchange of fuse Blown fuse indication by LED or neon lamp Before exchanging the
More informationMagnetic Overcurrent Circuit Breaker
Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically
More informationElectric actuators type EA25-250
Electric actuators type EA25-250 Small & Light Product description The actuators type EA25, EA45, EA120 and EA250 are not only excellently equipped, they also feature very high peak torques ranging from
More informationThermal-magnetic Miniature Circuit Breaker 4230-T...
Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail
More information1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions
Art. No. 232 ME Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please
More informationSmart-UPS On-Line Lithium-ion UPS 230V
Smart-UPS On-Line Lithium-ion UPS 230V Single-phase, rack/tower convertible, double conversion on-line UPS with Li-ion batteries and advanced management features A UPS developed for availability of your
More informationA.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual
Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323
More informationUninterruptible Power Supply
Uninterruptible Power Supply (DUPS-1232) Main Features Up to 32W Output, under 38W for 10 minutes. User-friendly interface - Dry Contact Communication. Wide input voltage range - 90~264Vac. Wall Mount
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More informationOFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility
OFF-GRID PV IVERTERS EssenSolar & Expert series Solution on Unstable or Remote Area without 1kW-5kW FSP Off-Gird Inverters: EssenSolar & Expert series An ideal Off-Grid inverter for households, FSP Off-Grid
More informationUser Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality
GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply
More informationINTELLIGENT MEDIUM POWERBAR
INTELLIGENT MEDIUM POWERBAR POWERBAR INTRODUCTION TECHNICAL FEATURES Intelligent Medium Powerbar is a patented range of busbar trunking that is utilized within Data Centers and various industrial applications
More informationDEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationPulsar EXtreme 2200C / 3200C
www.mgeups.com MGE UPS SYSTEMS Pulsar EXtreme 00C / 300C Installation and user manual P O W E R P R O V I D E R L E I B E R R U P T N T N I E U T H 3400753EN/AA - Page Introduction Thank you for selecting
More informationRutland Remote Display -Model Installation and Operation
Rutland Remote Display -Model 1200 Installation and Operation Introduction The Rutland Remote 1200 Model is designed for use with the Rutland 1200 Wind Turbine. It enables convenient viewing of the wind
More informationORVALDI Solar Infini 5kW
ORVALDI Solar Infini 5kW User manual Version: 1.0 Table Of Contents 1. Introduction... 1 2. Important Safety Warning... 2 3. Unpacking & Overview... 4 4. Installation... 5 5. Grid (Utility) Connection...
More information1. INTRODUCTION. Features:
1. INTRODUCTION This series is a compact and fully pure sinewave line interactive UPS, and it designs for critical application and environment, such as desktops, servers, workstations, and other networking
More informationTyre Health System (THS) Installation Manual
Tyre Health System (THS) Installation Manual Contents 1. TYRE HEALTH SYSTEM (THS) INSTRUCTION... 3 1.1. Prerequisites & Preparations... 3 1.1.1. Preparations:... 3 1.2. General information... 4 1.2.1.
More informationEC400 Power Control System
1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in section 3 or in the supporting technical manual available
More information3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:
TECHNICAL GUIDE SPECIFICATIONS Power-Lite Single Phase, (200 to 490 Watts) UL924 Central Lighting Inverter 1. SCOPE The Emergency Lighting Power System shall be a solid-state single phase unit designed
More informationADN-W CASE. Transport & Charging Case. Instruction manual
ADN-W CASE Transport & Charging Case Instruction manual Contents Contents For your safety... The ADN-W CASE transport and charging case... Package contents... Product overview ADN-W CASE transport and
More informationElectronic Circuit Breaker ESS20-0..
Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode
More informationModel ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM
4500 VA to 15500 VA SINGLE PHASE Model ES UNINTERRUPTIBLE POWER SYSTEM True online double conversion design with a field-proven track record of protecting mission critical applications and preventing downtime.
More informationDSEULTRA DSE6000 Quick Start Guide Document Number
n DSEULTRA DSE6000 Quick Start Guide Document Number 057-102 Author : John Ruddock Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099 Sales
More informationBBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER
BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER Important The BBC -3140 must be used according to the local safety standards with the particular application. All wiring and connections
More informationIVS Distribution System. IVS - Table of Contents
IVS - Table of Contents Overview System characteristics IVS System description Sheet steel wall-mounted DB for residential & functional buildings - IP30 Sheet steel wall-mounted DB for industrial applications
More information2.3 Cable reels for industrial applications. AUTOROLLER Series ROLLER330 Series ROLLER450 Series ROLLER-BLOCK Series
. reels for industrial applications. ROLLER0 ROLLER50 ROLLER-BLOCK 60 6 reels with automatic rewind. WITH H05VV-F PVC CABLE - IP Type Metres x 6 00 00 75.00-D poles x,5 500 00 75.05-D x,5 0 000 00 75.05-D
More informationSolarMax S series (Australia) Maximising solar plant yields can be so easy.
SolarMax S series (Australia) Maximising solar plant yields can be so easy. The convincing solution. We have been developing and producing transformerless inverters for over 20 years. Our engineers have
More informationUser Manual. Hybrid 4KW PV Inverter. Version: 1.2
User Manual Hybrid 4KW PV Inverter Version: 1.2 Table of Contents 1. Introduction... 1 2. Important Safety Warning... 2 3. Unpacking & Overview... 4 4. Installation... 5 4. Grid (Utility) Connection...
More informationGarden Lamps. Product Features. Applications
Garden Lamps V-TAC presents an elegant series of garden lighting- allowing your garden to glow in style when the sun goes down.step outside with our wide range of contemporary outdoor lighting and decorate
More informationUser Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work
GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)
More informationBACS BATTERY ANALYSIS & CARE SYSTEM
Monitoring, individual charging /discharging & alarm system for accumulators Avoid unnoticed or unexpected battery failures, extending the battery lifespan and preserving the reliability of the complete
More informationContent. How to use this document
Content Item Page No. UPS accessory selection table for single phase 1~3kVA UPS 3 UPS accessory selection table for single phase 5~10kVA UPS 4 UPS accessory selection table for three phase Monoblock UPS
More informationTechnical Documentation about limit switch boxes for rotary- and linear atuators acc. to guidline 94/9/EC, IBExU 07 ATEX 1155
Sensor-Boxes - 1 - Technical Documentation about limit switch boxes for rotary- and linear atuators acc. to guidline 94/9/EC, IBExU 07 ATEX 1155 II 2G Ex e d IIC T6 II 2D Ex td A21 IP65 T80 C Sensor-Boxes
More information1.1 Caution Statements
USER MANUAL 1.1 Caution Statements Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read and
More informationBC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual
BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct
More informationpartial statement 106 TITUS www.efb-elektronik.de 19 Networking cabinet TITUS S (Standard)... 108-109 19 Networking cabinet TITUS E (Enhanced)...110-111 19 Networking cabinet TITUS V (pre-assembled)...
More informationCBHD SERIES. Single-phase battery chargers. High frequency system with advanced technology. Lightweight & compact.
PRODUCTS CATALOGUE CBHD SERIES Single-phase battery chargers High frequency system with advanced technology Lightweight & compact Essential design Universal input voltage 100 Vac 240 Vac, 50 Hz 60 Hz Voltage
More informationUser Manual. SP10000 Premium
User Manual Solar Hybrid 3Phase PV Inverter SP10000 Premium Version: 1.2 Table Of Contents 1. Introduction... 1 2. Important Safety Warning... 2 3. Unpacking & Overview... 4 3-1. Packing List... 4 3-2.
More information1. Introduction OHY1P kW Hybrid Inverter USER MANUAL V2.0
1. Introduction OHY1P4805 5kW Hybrid Inverter USER MANUAL V2.0 1. Introduction Table of Contents 1. Introduction... 1 2. Important Safety Warning... 2 3. Unpacking & Overview... 4 4. Installation... 5
More informationIMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS
THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using
More informationWhad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF
Manuel d installation Installation manual Part. LE05733AA-07/12-01 GF Index 1 Introduction 18 2 Conditions for use 19 3 Installation 20 4 Visual and acoustic warning signals 22 5 ups diagnostic software
More informationMCD 200 Series Soft Starters
MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When
More informationTechnical Data Sheets
GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01
More informationUser Manual. Hybrid PV Inverter. Version: 2.1
User Manual Hybrid PV Inverter Version: 2.1 Table Of Contents 1. Introduction...1 2. Important Safety Warning...2 3. Unpacking & Overview...4 3-1. Packing List... 4 3-2. Product Overview... 4 4. Installation...5
More information& Operation Manual. Growatt 10000HY. Installation GR-UM-A03-A-00
Growatt 10000HY Installation & Operation Manual GROWATT NEW ENERGY TECHNOLOGY Co.,LTD No.28 Guangming Road, Shiyan, Baoan District, Shenzhen, P.R. China T F E W + 86 755 2747 1900 + 86 755 2747 2131 info@ginverter.com
More information