1 Harsh environments IEC/EN Wall sockets A p A p. 207 The contact carriers in plugs and sockets for harsh environments are made of especially resistant glass fibre reinforced polyamide. The contacts are nickelplated, the sleeve contacts are additionally protected by a resin-free oil. The recommended application areas are: 1. With especially high air humidity 2. In chemical aggressive atmosphere breweries wine press houses wine cellars ammonious and hydrogen-sulphidic atmospheres agricultural plants Mini combinations with Schuko socket + miniature fuse system G 16 and 32 A p. 209 Plugs with flexible cable entry or cable gland and A Appliance inlets wall mounting or flange and A p. 209 p hothouses saline environments like coastal areas salt mines salines Phase inverters, 16 and 32 A p. 211 Couplers with flexbible cable entry or cable gland and A p. 211 Panel sockets straight or angled and A p
2 b c d e f l n M external, 1 top cable entry, b c 5 5 d e f l n v 7 7 M 20/25 20/25 internal, 2 cable entries both, top and bottom, knock-out, Amp. 63 a 6 b 104 c 4.2 d 172 e 121 f 178 n 220 v 5 M 32 internal, cable entries: 1 x top (open), 2 x bottom (knock-out), and vice versa, b c 5 5 d e f l n u v 7 7 M 20/25 20/25 internal, 2 cable entries both, top and bottom (knock-out), Amp. 63 a 6 b 104 c 4.2 d 172 e 121 f 178 n 224 u 110 v 5 M 32 internal, cable entries: 1 x top (open), 2 x bottom (knock-out), and vice versa, Amp. 125 a 240 b 200 c 7 d 263 e 220 f 190 n 406 u 0 M 1 50/20 M 2 40 with multi contacts for high contact pressure and easy removal, cable entries: top: 1 x M 50 and 1 x M 20, bottom: 2 x M 40, with terminal block set 5 x 50 mm², 206
3 5 3 P + N + E Ampère Poles 110 V 4h 4h 4h 230 V 6h 9h 9h 400 V 9h 6h 6h 500 V 7h 7h 7h Part numbers Hz 10h 10h 10h ü Hz 2h 2h 2h g Ni Ni pic. 0NI Ni Ni pic. 1NI Ni 2 14 pic. 161NI Ni Ni pic. 9NI Ni pic. 169NI Ni pic. 179NI 207
4 b c 5 5 d e f l n v 7 7 M 20/25 20/25 Mini combinations, CEEtyp wall sockets with Schuko socket, 16 A, 230 V, 2P + E, 63 5 d Øe f m n Øp 8/21 11/241 15/33 Plugs, with flexible cable entry, 63 5 d Øe f m n Øp Plugs, d m n u Øp Plugs, Part no.: 610 Ni PH Ni 630 Ni PH Ni b c d e f l n M Part no.: 611 PH Ni 631 PH Ni (drawing like 611 PH and 631 PH) a b c d e f h n p y z Wall mounting appliance inlet, external, 1 top cable entry, also possible, depending on cable 63 5 a b c d e f h n p u y z Panel mounting appliance inlet, angled, flange screwed on, 208
5 5 3 P + N + E Ampère Poles 110 V 4h 4h 4h 230 V 6h 9h 9h 400 V 9h 6h 6h 500 V 7h 7h 7h Part numbers Hz 10h 10h 10h ü Hz 2h 2h 2h g Ni Ni pic. 5NI Ni Ni Ni pic. 230NI Ni Ni Ni 5 6 pic. 231NI Ni Ni Ni Ni pic. 239NI Ni PH Ni PH Ni pic. 630NI Ni PH Ni PH Ni Ni Ni Ni 5 6 pic. 639NI 209
6 Amp. 125 a 104 b 104 c 6.5 d 0 e 0 f 93 h 90 n 56 p 7.5 u 0 Panel mounting appliance inlet, straight, flange screwed on, d Øe f m n Øp 8/21 11/24 Phase inverters, with flexible cable entry, d Øe f m n Øp Phase inverters, 63 5 d Øe f m Øp 8/21 11/24 15/33 Couplers, with flexible cable entry, 63 5 d Øe f m Øp Couplers, d f m u Øp Couplers, 210
7 5 3 P + N + E Ampère Poles 110 V 4h 4h 4h 230 V 6h 9h 9h 400 V 9h 6h 6h 500 V 7h 7h 7h Part numbers Hz 10h 10h 10h ü Hz 2h 2h 2h g Ni pic. 679NI PH Ni PH Ni pic. 230PHNI PH Ni PH Ni pic. 231PHNI Ni Ni Ni pic. 330NI Ni Ni Ni pic. 331NI Ni Ni Ni Ni pic. 339NI 211
8 a b c d e f h n p 9 9 Panel sockets, straight, Flange dimensions 75 x 75 mm, fingerproof acc. to BGV A2, Amp. 63 a 85 b 77 c 6.5 d 107 e 100 f 85 h 90 n 52 p 12 Panel socket, straight, Flange dimensions 107 x 100 mm, fingerproof acc. to BGV A2, a b c d e f h n p u Panel sockets, straight, A fingerproof acc. to BGV A2, 125 A handproof acc. to BGV A2, 63 5 a b c d e f h n p r y z Panel sockets, angled, fingerproof acc. to BVG A2, 63 5 a b c d e f h n p r y z Panel sockets, angled, A fingerproof acc. to BGV A2, a b c d e f h n p r u y z Panel sockets, angled, A fingerproof acc. to BGV A2, 125 A handproof acc. to BGV A2, 212
9 5 3 P + N + E Ampère Poles 110 V 4h 4h 4h 230 V 6h 9h 9h 400 V 9h 6h 6h 500 V 7h 7h 7h Part numbers Hz 10h 10h 10h ü Hz 2h 2h 2h g Ni Ni pic. 430NI Ni pic. 460NI Ni Ni Ni Ni 2 19 pic. 439NI Ni Ni Ni pic. 530NI Ni Ni Ni pic. 532NI Ni Ni Ni Ni 2 16 pic. 539NI 2
Pin and socket connectors
All-rubber connectors with earthing contact ( Schuko ) All-rubber connectors with earthing contact water proof ( Schuko- WD ) All-rubber CEE connectors All-rubber reducers Some general explanations Schuko
More informationPin and socket connectors
All-rubber connectors with earthing contact ( Schuko ) All-rubber connectors with earthing contact water proof ( Schuko-WD ) All-rubber CEE connectors All-rubber reducers All-rubber earthing schuko connectors
More informationUnused flameproof threads for cable glands have to be closed with certified plugs.
E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.
More informationInternational approvals.
E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in
More informationI 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I
I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationSafety Performance WORLD PREMIERE. palazzoli.com 1
Safety Performance WORLD PREMIERE palazzoli.com 1 The inventions that progressed our life Benjamin Franklin Energy and persistence conquer all things. The lightning rod 2 The inventions that progressed
More informationEPIC. Pin & Sleeve Connectors PIN & SLEEVE CONNECTORS
PIN & SLEEVE CONNECTORS Reference Pin & Sleeve Overview 461 Pin & Sleeve Products Overview 462 CEE series, MULTIMAX series, ULYSSE series, ALUPRES series Pin & Sleeve Construction 464 MULTIMAX Installation
More informationP r o d u c t o v e r v i e w
Product Overview Bals, a company in partnership with its customers The Bals company was established in Germany over 50 years ago. It manufactures an extensive range of high quality indus-trial plugs and
More informationADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices
ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS Without protective devices Interlocked-switch socket outlets QUADRA Series socket outlets For 16 and 32 A currents Protection degree
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationTUNNEL54. Safety and fire resistance VENTILATION LIGHTING
TUNNEL54 Safety and fire resistance VENTILATION LIGHTING 238 TUNNEL54 Safety and fire resistance VENTILATION TUNNEL54 fire resistant sockets for ventilators Page 240 LIGHTING TUNNEL54 junction boxes with
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationIEC60309 PLUGS AND SOCKETS
High performance for each condition and every environment The industrial plugs and sockets are designed to withstand highly specific operating conditions that widely vary depending in which place and situation
More informationCEEtyp PLUGS AND SOCKETS
CEEtyp PLUGS AND SOCKETS The indicated extracts out of standards are for your information but without any liability. In case of doubt please refer to the complete original standard or regulation. The quotations
More informationPK Industrial Plugs and Sockets. Catalogue
PK Industrial Plugs and Sockets Catalogue 2004-2005 PK industrial plugs and sockets General index PK plugs and sockets low voltage General presentation 4 Selection guide 10 Wander plugs - PK PratiKa FST
More information10 Load and Motor Switchgear
10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationResidual Current Protective Devices / Arc Fault Detection Devices (AFDDs)
Introduction Overview Devices Page Application Standards Used in / Personnel, material and fire protection, as well as protection against direct contact. SIGRES with active condensation protection for
More informationAC Mining Motors. AC Motors for the Continuous Miner
AC Mining Motors AC Motors for the Continuous Miner CUTTERHEAD Motor - 175 kw 50 Hz S1 340 HP 60 Hz S1 New motor for Mega-head application. This motor drives the cutter head on the Joy 12HM31 continuous
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated
More informationBOXES AND BOARDS. Versatility and modularity of solutions and materials STANDARD HEAVY DUTY
BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD HEAVY DUTY 8 BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD PRIMA topter empty distribution
More informationMTF. Technical features
Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz or 60Hz or 100-130V, 60Hz and 200-240V, 50Hz ( types are supplied without capacitor); suitable for use with an inverter from 20Hz
More informationATX PRE Series 63 Amp Plugs and Sockets Increased Safety
ATX PRE Series 63 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact
More informationTechnical Data Sheet VENUS FLA SCM
VENUS FLA SCM VENUS Material Outside Material Component Material Colour Flammability Back panel ASA UV stabilized, halogen free grey, RAL 7040 UL94-HB Cover ASA UV stabilized, halogen free grey, RAL 7040
More informationMTF-E. Technical features
Technical features Power supply Threephase voltage from 220V to 690V, 50Hz or 60Hz; suitable for use with a PM inverter from 20Hz to the base frequency with constant torque load profile. Polarity 2 and
More informationCOMMANDO. Commando offers a comprehensive range of industrial plugs, connectors, socket outlets, appliance inlets, Combi and Modular-Combi units.
WIRING DEVICES COMMANDO RANGE INTRODUCTION Commando offers a comprehensive range of industrial plugs, connectors, socket outlets, appliance inlets, Combi and Modular-Combi units. The Commando range is
More informationELECTRICAL CONNECTIVITY
ELECTRICAL CONNECTIVITY EXLINK -POLE/-POLE + PE. EXLINK ETHERNET/USB EXLINK -POLE+PE.. MULTI-PURPOSE TERMINAL PLUGS AND RECEPTACLES FOR ZONE 0 A.. PLUGS AND RECEPTACLES FOR ZONE A PLUGS AND RECEPTACLES
More informationATX PRE Series 125 Amp Plugs and Sockets Increased Safety
ATX PRE Series 125 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More information67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS
Technical data and compliance with Standards Component Interlocked switched socket-outlets SELV socket-outlet Rotary switch MT60 miniature circuit breaker, C characteristic, 6kA Reference Standards EN
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationPage - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 202 PERFORMANCE CHART VOX 203 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 DIAGRAM AND ELECTRIC CONNECTIONS 302 DIAGRAM
More informationEmergency Light Fittings
Emergency Light Fittings 164 131 208/... 218/25.. SCHUCH Emergency Light Fittings NEW 164 218/25.. Dustproof/waterproof emergency light fitting for wind power stations. Description Series Page Polyester
More informationCSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller
CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys
More informationOutput signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V
Duct Sensor Humidity / Temperature Duct mounted combined humidity (VDC) and temperature sensor. 2% accurate rh, available with dual active outputs or passive for temperature. Nema 4X / IP65 rated enclosure.
More informationAxial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.
xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof
More informationVigilant Automatic Transfer Switches
Vigilant Automatic Transfer Switches 100A to 1250A The Vigilant Series ATS is designed to automatically transfer critical loads in the event of a power outage. It consists of a simple, rugged design while
More informationQuick and Easy Voltage Flexibility for NEMA and Metric IEC Motors Motors are re-rated from stock models to 575V in as little as (1) business day
Elektrim 7V s Quick and Easy Voltage Flexibility for NEMA and Metric IEC s s are re-rated from stock models to 7V in as little as () business day Available 7V s: -0 HP NEMA Premium Performance Series s
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationZone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108
Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating
More informationControl Device System NEC Series ConSig 8040
16113E00 > Enclosure made of glass fibre reinforced polyester resin > Modular design > 3 sizes available > Individual units can be combined into larger units > Standard and customer-specific versions >
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationDNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A SILVER-NICKEL BUTT CONTACTS
DNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A AUTOMATIC IP54/ WATER- AND DUST-TIGHT IMPACT-RESISTANT METAL CASING SUITABLE FOR HEAVY INDUSTRY The DN family of decontactors cover ratings from 30
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationPOND PUMP Model Nos:SPP3 & SPP6 0200
OPERATING & MAINTENANCE INSTRUCTIONS POND PUMP Model Nos:SPP3 & SPP6 0200 Thank you for purchasing this CLARKE Water Pump, which is particularly suitable for the filtration of small to medium size swimming
More informationSpec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number
Spec Sheet: IEC309 Panel Socket, Angled 16A IP67 Part Numbers Part Number EU67SA316 EU67SA416 EU67SA516 Specification Description IEC309 16A 3 Pin panel socket, angled, IP67 IEC309 16A 4 Pin panel socket,
More information3 Pin Schuko Converter Plug Technical Data & Fitting Instructions
3 Pin Schuko Converter Plug Technical Data & Fitting Instructions Description The 3 Pin Schuko Converter Plug (SCP3) is an adapter that converts the European IEC 83:1975 Standard C 2b, C4, C5, and C6 plug
More informationEPIC Pin & Sleeve Connectors EPIC
EPIC 1 Courtesy of Steven Engineering, Inc.-20 Ryan Way, South San Francisco, CA 080-0-Main Office: (0) 88-200-Outside Local Area: (800) 28-200-www.stevenengineering.com Global Power Connectors for the
More informationInstallation Accessories
Installation Accessories Elektrostatische Aufladung vermeiden. Nur mit feuchtem Tuch säubern. Evitez lez charges electrotetiques Nettoyer unkjuement avec un chifion humide. Avold electrostatic charge.
More informationTHERMASGARD TF 43 THERMASGARD TF 65
THERMASGARD TF 65 Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) THERMASGARD TF 43 is a resistance thermometer with a passive output, enclosure made from impact-resistant plastic
More informationSpec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number
Spec Sheet: IEC309 Switched Socket, Horizontal 16A Part Numbers Part Number EU67HSS316 EU67HSS416 EU67HSS516 Description IEC309 16A 3 Pin switched socket IEC309 16A 4 Pin switched socket IEC309 16A 5 Pin
More informationPressure switch hex 27
Pressure switch Changeover switch with silver or gold contacts Easily adjustable switching point. Factory adjustable hysteresis (except type 0140/014. High overpressure safety and long life even under
More informationPRE Series 63 Amp Plugs and Sockets Increased Safety
Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator sets Air conditionings Compressors
More informationOperating instruction and technical description
Operating instruction and technical description EV Simulator for charging devices with charging plug / charging coupler / charging cable type 1 and type 2 as service case Photo: EV simulator/tester with
More informationRated current In (A) Other electrical data. IEC 309 range. EN see 70 RT range IK
44 and 67 IB standard horizontal and vertical socket-outlets Industrial-type socket-outlets conforming to IEC 309 Standard, with mechanical interlock consisting of a circuit breaker enabling the plug to
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear
More informationProducts for. Section
2 Products for Section Chemical Industries Grain silos Oil and Gas industry Plastics Fertilisers and insecticides Wood Cosmetics and perfumes lcohol and spirits Pharmaceutical Industries, etc. 90 2005-2006
More informationMain current switches >180 A are realized in metal enclosures. Internationally approved.
E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility
More informationMINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR
MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR Explosion protection Certificate of Conformity: Frame size 71 and 160 Frame size 80, 90, 100, 112, 132 Frame size 180, 200, 225 Frame size 250 Frame size 280
More informationPRE Series 125 Amp Plugs and Sockets Increased Safety
s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 125 Amp s and Sockets - IK10 Applications s and sockets are used with stationary or portable electrically operated devices
More informationValves of stainless steel COMPACT-Program C D
SUT-O Valves VALVES STAINLESS STEEL CNA 50 1000 mm Shut-Off-Valves GO WIT OUR LOW Valves CNA 50 1000 mm MARTIN LOSE Gmb Unteres Paradies 63 D-89522 eidenheim Postfach 1565 D-89505 eidenheim server.ab@lohse-gmbh.de
More informationE N V I R O N M E N T A L P R O T E C T I O N F O R Y O U R C O N N E C T I O N S
E N V I R O N M E N T A L P R O T E C T I O N F O R Y O U R C O N N E C T I O N S Controlwell presents a range of Junction Boxes manufactured from Halogen-free ABS, which offers superior resistance to
More informationW DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO
W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W SCHRACK-INFO Lift and clamp terminals on both sides Terminal guide for secure connection Terminal cross-section: 1-25mm² Snap-on mounting for
More informationProduct Guide. NEMA pump controls.
Product Guide NEMA pump controls www.usa.siemens.com/controls Class 87 full voltage pump controller with fusible disconnect switch and standard features Class 87 NEMA full starter pump control panels Product
More informationINDUSTRIAL PLUGS AND SOCKETS. Optima, Eureka, Xenia, IEC309 Series
INDUSTRIAL PLUGS AND SOCKETS Optima, Eureka, Xenia, IEC309 Series Scame: a tradition of innovation IN FIFTY YEARS WE HAVE WRITTEN A STORY OF INNOVATION THAT HAS ALWAYS PRESERVED THE SPIRIT OF ITS ORIGINS.
More informationEPIC. EPIC Pin & Sleeve Connectors MARYLAND METRICS. LAPP products are available from
LAPP products are available from MARYLAND METRICS P.O. Box 21 Owings Mills, MD 2111 USA ph:(10)8-10 (800)8-180 fx:(10)8-12 (800)82-2 RFQ form: http://mdmetric.com/rfq.htm Lapp Index Page: http://mdmetric.com/elect/contents.htm
More informationGENERAL CATALOGUE Leading Electrotechnology
GENERAL CATALOGUE 2014-2015 Leading Electrotechnology THE WORLD HAS CHOSEN PALAZZOLI excellence FROM ITALY The globalisation process no longer allows for Made in Italy to be the only mark of differentiation
More informationHydraulics BALL AND GATE VALVES
Hydraulics BALL AND GATE VALVES PRODUCT INDEX A comprehensive range of ball valves is available to suit most fluid control applications. Port sizes range from ¹ ₄ in to 4 in. Female thread forms are provided
More informationMINING ELECTRIC MOTORS 3KTCR AND 4KTCR
MINING ELECTRIC MOTORS 3KTCR AND 4KTCR Explosion protection Certificate of Conformity: Frame size 71 and 160 Frame size 80, 90, 100, 112, 132 Frame size 180, 200, 225 Frame size 250 Frame size 280 Frame
More informationINDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com
More informationPORTS, MARINAS, SHIPYARDS & VESSELS
PORTS, MARINAS, SHIPYARDS & VESSELS INDUSTRIAL PLUGS & SOCKET-OUTLETS SAFE AND RELIABLE ELECTRICAL CONNECTIONS IDEALLY SUITED TO PORTS, MARINAS, SHIPYARDS & VESSELS MARECHAL ELECTRIC offers a range of
More informationZone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008
Lighting Technology Emergency Light Fittings Can be used in Zone 1 and Zone 2 As pendant or pole-mounting fittings For single- and two-pin fluorescent lamps With electronic ballast and integral emergency
More informationHypra and P 17 industrial sockets
[ INUSTRIL SOKTS ] Products and systems ypra and P 17 industrial sockets 2 ranges cover 3 levels of weatherproofing: IP 44, IP 66/67 and IP 66/67-55: ypra is recommended for harsh environments (dust, water
More informationGross Automation (877)
Limit Switches Carlo Gavazzi broadens its leading range of products for the industrial automation world, with the new and complete range of mechanical limit and safety switches. These robust switches provide
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More informationI Ex-Safety switches I
3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX
More informationI Ex-safety switches I
3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99
More information1.6 CEEGO Series...from page c.42. The CEEGO range, in both single and 3-phase, is manufactured in current ratings of 16, 32, 63 and 125 amperes.
1.6 CEEGO Series.....................................................................................................from page c.42 The CEEGO range, in both single and 3-phase, is manufactured in current
More informationMoisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories
Branch and lustre terminals Apparatus and light terminals Porcelain terminals Screwless terminals Flat plug terminals Flat plug branch terminals Mains branch terminals Connection terminals Earthed wire
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationTechnical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10
Technical Data BEST 2~5 Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_ CONTENTS -SPECIFICATIONS Page Features & Applications 100 Exploded View 101 Pump & Motor
More informationLow and Extra-Low voltage. PratiKa. Industrial plugs and sockets. Offer panorama
Low and Extra-Low voltage PratiKa Industrial plugs and sockets Offer panorama Presentation PratiKa plugs and sockets General presentation PB102249 Additional safety is assured by sockets with electrical
More informationOperating Instructions Overcurrent Protection - Tester
Operating Instructions Overcurrent Protection - Tester WWW.LECOM.CN CONTENTS Table of contents 1. ORDER REFERENCE...2 1.1. Standard set...2 1.2. Options...3 2. INTRODUCTION...4 2.1. General description...4
More informationFree-Form Optics. Heavy Duty Bulb. Heavy Duty Mounts
Free-Form Optics Nordic Lights through their expertise in lens and reflector technology offer a range of light patterns to satisfy the varied and specialist lighting requirements of the mining, heavy duty
More informationPermissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance
IEC 309 HP technical characteristics New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IEC 60309-1 and
More information7 Lighting Technology
7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources
More informationMarine Solutions. June 20, Author : Siemens Energy & Automation, Thomas Orberger Your Success is Our Goal
Marine Solutions June 20, 2003 Author : Siemens Energy & Automation, Thomas Orberger Your Success is Our Goal System Overview Water Cooling Unit 1 Control Unit 1/2 DUO-Inverter G G CAN System Bus Gateway
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationBattery Boxes Series 8316
www.stahl.de > Back-up power supply > Maintenance-free batteries > Low self-discharge > Extremely low gas emissions > Electrolyte-tight > No acid surface coating > Protection against total disch arge >
More information