1 HMC Connectors February, 007

2 Section TRADE PRICE SCHEDULE Effective February, 007 CONTENTS Circuit Boss Encapsulated Cable Blocks & Splices / Reducers Pages - 6 Modular Power Distribution Block System Pages 7 - Aluminum Mechanical Connectors Pages Aluminum Mechanical Pedestal Connectors Pages Aluminum Mechanical Transformer Connectors Pages 5-6 Insulating Boots for Pedestal & Transformer Connectors Pages Aluminum Compression Splices, Lugs, Tees & Pin Terminals Pages Aluminum Compression Service Entrance Splices Pages Copper Mechanical Connectors Pages Copper Compression Connectors Pages Split Bolts & Two Bolt Connectors Pages 87-9 Grounding Connectors & Clamps Pages 9-0 Direct Burial Flood-Seal Splice Kits Pages Heat-Shrink Splice Kits Pages Street & Highway Lighting Connectors & Kits Pages Multi-Seal Multi-Port Connectors Pages 7-7 Flood-Seal & Sweetheart Connectors Pages Barracuda Insulation Piercing Connectors Pages Tools & Accessories Pages Terms & Conditions of Sale Pages HMC INDUSTRIES NAED VENDOR # 7850 (this is the 6-digit number assigned to HMC). The Trade Price Schedule also has a # assigned to each product. Southland Road, Ormond Beach, FL 74 Telephone:

3 TRADE PRICE SCHEDULE Effective February, 007 ALPHA-NUMERIC INDEX Catalog Catalog Catalog Catalog p CP p CP p.50 5-CAD p.5 5-CAO p.5 5-CAP p.5 5-CA-R p.5 5-CN p.5 5-C-R p.5 5-CZ p p p p p p.00 A A p.5 A-CT p.5 ABC p., 4 ABN p.9 ABT p.0, ABW p.7, 8 AC-TN p.40 AD p.7 AD-N p.7 AE p.90 A-L p.9 AL-4-NTN p.46 AL-NTN p.44 AL-NTNV p.49 AL-TN p.4 AL-TNV p.49 A-N p.6 ANA p.0 AQ p.9 ASC-TN p.9 ASG p.6 ASL-NTN p.45 AT p.50 AT---N p.8 AT--4-N p.8 AT-4-4-N p.8 ATC p.4 ATC-R p.4 ATT p.5 AX p.9 B B p.84 BA p.0 BB p.5 BMS p.5 BY p.9 C C p.70 CB p.65 CBA p.65 CBS p.66 CC p.95 CD p.64 CD-B p.59 CLA p.9 CN-B p.59 CO p.65 CO-B p.59 CP p.6 CS p.64 CS (rocket) p.7 CSB p., 4 CSB-S p.5 CSN p.7 CSR p.5 CST p.7 CX p.64 D DB p.58 DC p.65 DYA p. DYC p. DYU p. DYU-M p. E E p.89 E p.84 E-GP p.89 EP p.5 F FB p.5 FB-L p.5 FB-NR p.0 FB-R p.0 FS p.7 FS-S p.7 FS p.5, 6 FS-CU p.6 FS-DPK p.5 FSK p.07 FSK-R p.07 FSS p.05, 5 FSS-L p.5 FSS-S p.5 FYA p. FYC p. FYU p. FYU-M p. G G p.84 GG p.00 GHD p.0 GHN p.0 GHO p.0 H H p.50 HAL p.9, 0, HAM p.9, 0, HAS p.9, 0, HCL p. HCM p. HCS p. HD p.0 HDL-4-N p.8 HDL-N p.8 HEG p.97, 98 HG p.96, 97, 98 HG-AW p.97 HG-BS p.96, 97 HG-BZ p.96 HG-DB p.96, 97 HG-EBS p.98 HGH p.98 HGHM p.98 HGRC p.99 HGRC-HD p.99 HGRCP p.99 HG-Z p.96 HG-ZB p.96 HL p.79, 80 HL-4-N p.8 HL-N p.8 HM p.54 HM p.5 HN p.0 HO p.0 HPE p.54 HPG p.54 HSK p.05 I IPST p.46 K K p.84 L L p.74, 75, 76 L-4-N p.78 L-N p.76 L-NV p.8 L-V p.8 M M p.84 ML p.6 MSL p.48 MTB p.05 Southland Road, Ormond Beach, FL 74 Telephone:

4 TRADE PRICE SCHEDULE Effective February, 007 ALPHA-NUMERIC INDEX Catalog Catalog Catalog N NB p.58 NBL p.66 O OB p.58 P PC p.7 PTC p.7 Q Q--U p.57 R RAB-/ p.9 RAB p.0 RAB p. RB p.9 REC p.5 RIPC DISCONTINUED RIPS DISCONTINUED RRK p.06 RRK-HS p. RXL p. RXL p. RXM p. S SAKM p.47 SA-NTN p.44 SB p.5 SB-BG p.5 SC p.69 SDK p.0 SDK-M p. SDT p.0 SDT-M p. SHC p.8 SHC p.8 SHC-4/ p.9 SHC p.8 SHC-500-4/ p.9 SL-K p.05 SL-N p.77 SLK p.0 SLK-M p. SLT p.0 SLT-M p. SLV p.9 T T p.85 TBC p.9 TBC-GP p.9 TBC-S p.9 TC p.7 TL p.54 TT p.86 U U p.56 U--B p.55 U--N p.55 UB p.58 U-BB p.56 U-BBR p.56 U-BG p.56 U-OB p.56 U-OBR p.56 U-OG p.56 U-OO p.56 U-RB p.56 U-RBR p.56 U-RG p.56 U-RO p.56 U-RR p.56 U-YB p.56 U-YBR p.56 U-YG p.56 U-YO p.56 U-YR p.56 U-YY p.56 UF p.05 UGBR p.56 UGG p.56 UH p.05 UH p.40 UH p.40 UH p.40, 4 UH-750-4/ p.4 UH p.4 UH p.4 UH p.4 UH-SL p.05 ULCK p.09 ULCK-HS p.5 ULSK p.08 ULSK-HS p.4 UOB p.56 UOG p.56 URS p.05 US p.0 USK p.05 USK-SL p.05 UT p.54 UT p.5 UT-5-N p.5 UT p.49 UT--M p.49 UT p.50 UT-5-PB p.50 UT-5-W p.50 UT p.54 UT-B p.5 UT-C p.5 W WA p.5 Y YDA p. YDC p. YDU p.4 YFA p. YFC p. YFU p.4 Z ZB p.58 ZBT p. ZBT-DS p. Southland Road, Ormond Beach, FL 74 Telephone:

5 Circuit Boss Encapsulated Cable Blocks & Splices/Reducers CSB Series Cable Blocks CSR Series Dual Rated Splices / Reducers

6

7 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Multi-Tap Encapsulated Cable Blocks - Two Way Configuration Dual-rated, clear PVC insulated CSB 4 SERIES Conductor Catalog 8060 CSB 4- CSB /0 SERIES Conductor Catalog 806 CSB /0- CSB 50 SERIES Conductor Catalog 8064 CSB 50- Range Range Range # Outlets Hex Size 8065 CSB #6 5 5/6 4 5/ Dimensions (inches) Length Width Height 7/ CSB 50-7/ CSB / CSB / CSB / CSB /64 5/8 /8 6 4 Circuit Boss File E50999 HMC Industries encapsulated cable blocks will make a safe and time-saving installation. Made from the highest quality material, and insulated with clear PVC, they are dual-rated for use with aluminum or copper conductor. Rated at 95 C for use at 600 volts maximum, they meet and exceed ANSI C9.4. No taping is required, one conductor per wire hole and screw. All you need is a hex key to make your installations. # Outlets # Outlets Hex Size 806 CSB /0-5 /0 - #4 5 /6 7/ CSB / / CSB / /8 Screw Type 8060 CSB 4-5 #4 - #4 5 Slotted 9/6 806 CSB / CSB /6 Dimensions (inches) Length Width Height 5/ CSB /0- / CSB /0-4 4 / CSB / /8 Dimensions (inches) Length Width Height / CSB 4-9/ CSB / CSB /6 5/8 5/6 /4 / Southland Road, Ormond Beach, FL 74 Telephone:

8 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Multi-Tap Encapsulated Cable Blocks - Two Way Configuration Dual-rated, clear PVC insulated Circuit Boss File E50999 CSB 50 SERIES Conductor Catalog CSB 50- Range # Outlets Hex Size 8067 CSB #0 5 /8 5 / CSB / CSB / CSB /4 Dimensions (inches) Length Width Height / CSB 50- / CSB /4 /8 / 4 CSB 500 SERIES Conductor Catalog CSB 500- Range # Outlets Hex Size 7/ CSB / CSB /8 Dimensions (inches) Length Width Height CSB #6 5 /8 6 5/8 /6 / CSB / CSB / CSB /8 4 CSB 750 SERIES * Conductor Catalog CSB 750- Range # Outlets Hex Size CSB / CSB / CSB / CSB /0 6 /8 8 5/ CSB CSB /6 807 CSB /6 807 CSB /4 Dimensions (inches) Length Width Height /8 /4 * Not UL listed. 4 Southland Road, Ormond Beach, FL 74 Telephone:

9 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Multi-Tap Encapsulated Cable Blocks - One Way Configuration Dual-rated, clear PVC insulated, single sided CSB-S SERIES Conductor # Screw Dimensions (inches) Catalog Range Outlets Type Length Width Height 6885 CSB 4-4 S 4 /8 hex / CSB 4-5 S 5 #4 - #4 Slotted 9/ CSB 4-6 S 6 /6 /8 5/ CSB 4-8 S 8 /8 hex 4 / CSB /0- S /0 - #4 /6 hex /8 /4 / CSB 50-5 S 50 - #6 5 5 /4 /4 / CSB 50-4 S 4 4 /4 /8 hex 689 CSB 50-5 S 50 - #0 5 5 /4 /8 / 689 CSB 50-8 S 8 8 / CSB S 4 5 / #6 /8 hex /6 / CSB S 6 7 7/8 Aluminum Encapsulated Splices/Reducers Dual-rated, clear PVC insulated CSR SERIES For other sizes or configurations, please consult the factory. Conductor # Hex Dimensions (inches) Catalog Range Outlets Size Length Width Height 0700 CSR /0 #4 - /0 /4 7/8 / CSR 50 # /8 /8 /8 /8 070 CSR 50 # /4 /8 / 075 CSR 500 / / 5/8 7/8 Circuit Boss File E Southland Road, Ormond Beach, FL 74 Telephone:

10 6

11 Modular Power Distribution Block System Modular Distribution Blocks Covers 7

12 8

13 TRADE PRICE SCHEDULE Effective February, 007 Modular Power Distribution Block System Single Primary - Multiple Secondary Dual-rated, compact, versatile, 90 C rated, 600 volts, durable, high impact bases, one piece connectors, no assembly HA SERIES Catalog 040 HAS K H4 040 HAS K H6 040 HAM P H HAM P H #4 - /0 Each block can stand alone or combine with other blocks to form a multi-block set. Add as many holes as you need, in any configuration you want. There are no end pieces or connector pieces to handle. The connector body is made form high-strength, high conductivity aluminum alloy and is mounted in a highstrength, glass-filled polyester base. Conductor Range AMPS Dimensions (inches) Line Side Load Side per pole Length Width Height #4 - #4 # / / / 4 / 5/ HAL P K6 #4 - /0 5 / 9/ / HAM R H #4 - # HAL R K6 #4-500 #4 - / HAL R M4 #6-4/ / 5/8 5 / 9/ / HAL V K #4 - / Southland Road, Ormond Beach, FL 74 Telephone:

14 TRADE PRICE SCHEDULE Effective February, 007 Modular Power Distribution Block System Double Primary - Multiple Secondary Dual-rated, compact, versatile, 90 C rated, 600 volts, durable, high impact bases, one piece connectors, no assembly HA SERIES Catalog Conductor Range AMPS Dimensions (inches) Line Side Load Side per pole Length Width Height 040 HAS K H6 9/ / / 040 HAM K H6 #4 - #4 #4 - / HAM K H 4 / 5/ HAM K I6 #4 - # 0406 HAL P H #4 - #4 # HAL P K6 #4 - / HAL R H #4 - #4 5 / 9/ / HAL R K6 #4-500 #4 - / HAL R M4 #6-4/0 0 Southland Road, Ormond Beach, FL 74 Telephone:

15 TRADE PRICE SCHEDULE Effective February, 007 Modular Power Distribution Block System Splicer / Reducer (Single Primary - Single Secondary / Double Primary - Double Secondary) Dual-rated, compact, versatile, 90 C rated, 600 volts, durable, high impact bases, one piece connectors, no assembly HA SERIES Catalog Conductor Range AMPS Dimensions (inches) Line Side Load Side per pole Length Width Height 0400 HAS I I #4 - # #4 - # HAS K K #4 - /0 #4 - / HAM N N #6-50 # HAM P P #6-50 # HAM R R #4-500 # / / / 4 / 5/ HAS K K #4 - /0 #4 - /0 50 9/ / / HAL P P #6-50 # HAL R R #4-500 # / 9/ /4 Covers Clear acrylic covers permit visual inspection. It snaps easily into place; no need for time-consuming screws. Just three sizes fit most styles and configurations of HMC Modular Power Distribution Blocks. Catalog For Use With Power Distribution Block Series With Prefix HCS HAS * 0400 HCM HAM HCL HAL * Not suitable for use with the following catalog numbers: HAS K H6, HAS K K, HAS K H6 Southland Road, Ormond Beach, FL 74 Telephone:

16

17 Aluminum Mechanical Connectors Lugs Neutral Bar Assemblies Splices/Reducers

18 4

19 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated One Barrel Mechanical Lugs Dual-rated File E50999 File LR 5607 Figure Figure A SERIES - ONE HOLE Catalog Figure Conductor Range Bolt Size Dimensions (inches) Height Width Length Lbs Per 00 Pcs A 5 #6 - #4 / /8 / A 90 # - #4 9/6 / 5/ / A 5 /0 - #4. /6 5/8 5/ A 50 /0 - # A #6 /6 5/ A #6 5/ A #6 /4 /8 / A #6 / /4. / A 600 CT #4 or 50 - /0 /8 /6 / A #4 / /6 /4 890 A /4 / / 46. 5/ A /4 / / Slotted screw. Southland Road, Ormond Beach, FL 74 Telephone:

20 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated One Barrel Mechanical Lugs Dual-rated File E50999 File LR 5607 Figure Figure Figure Figure 4 Figure 5 Figure 6 A-N SERIES - TWO HOLE Figure Bolt Dimensions (inches) Lbs Per Catalog Conductor Range Size Height Width Length 00 Pcs A 50- N 50 - #6 /8 /8 4 / A 600- N #4 9/6 / 4 / / A 800- N /8 /4 6 / A 000- N /8 /4 6 / ASG SERIES - TWO HOLE SWITCHGEAR TYPE Figure Bolt Dimensions (inches) Catalog Conductor Range Size Height Width Length 67 ASG # - #8 5/8 /4 67 ASG /0 * /0 - #8 /8 5/6 674 ASG / ASG /0 /8 5 9/6 4 / ASG / /8 675 ASG /8 5/8 6 /6 Lbs Per 00 Pcs. Consult factory N suffix on the catalog number indicates NEMA bolt hole spacing of /4. * Not UL listed. Not CSA listed. 6 Southland Road, Ormond Beach, FL 74 Telephone:

21 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Two Barrel Mechanical Lugs Dual-rated File E50999 File LR 5607 Figure Figure Figure Figure 4 AD SERIES - ONE HOLE Figure Bolt Dimensions (inches) Catalog Conductor Range Size Height Width Length AD 5 /0 - #4 /4 /6 /6 / AD 50 /0 - # AD #6 /8 /6 5/8 9/ AD #6 /4 5/6 7/ AD #4 / /6 /8 / AD # AD /8 /6 /6 / AD 000 * AD-N SERIES - TWO HOLE Lbs Per 00 Pcs. 7.5 Figure Bolt Dimensions (inches) Lbs Per Catalog Conductor Range Size Height Width Length 00 Pcs. 008 AD 50- N 50 - #6 /8 /4 4 / AD 600- N #4 / 9/6 /8 / AD 800- N * /8 /6 6 / N suffix on the catalog number indicates NEMA bolt hole spacing of /4. * Not UL listed. Not CSA listed. Southland Road, Ormond Beach, FL 74 Telephone:

22 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Three & Four Barrel Mechanical Lugs Dual-rated Figure Figure Figure Figure 4 Figure 5 Figure 6 AT A N SERIES - THREE BARREL TWO HOLE Catalog Figure Conductor Range Bolt Size Dimensions (inches) Height Width Length 8895 AT A -/0 N /0 - #6 /6 /6 4 / AT A -50 N 50 - #6 /8 /6 4 / AT A -50 N 50 - #6 /4 4 /6 / AT A -600 N # 9/6 /4 4 5/ AT A -800 N /8 4 /4 6 / AT A -000 N /8 4 /4 6 /6 Lbs Per 00 Pcs. Consult factory AT A 4 N SERIES - THREE BARREL FOUR HOLE Figure Bolt Dimensions (inches) Catalog Conductor Range Size Height Width Length AT A 4-50 N 50 - #6 /4 /6 4 / AT A 4-50 N 50 - #6 /4 4 /6 674 AT A N # 9/6 /4 4 /6 / AT A N # /4 /4 4 5/ AT A N /8 4 /4 6 / AT A N /8 4 /4 6 /6 Lbs Per 00 Pcs. Consult factory AT 4 A 4 N SERIES - FOUR BARREL FOUR HOLE Figure Bolt Dimensions (inches) Lbs Per Catalog Conductor Range Size Height Width Length 00 Pcs AT 4 A 4-50 N 50 - #6 /6 /4 4 / AT 4 A 4-50 N #6 5/6 Consult / AT 4 A N # 9/6 5 4 /6 factory 8896 AT 4 A N /8 5 5/8 6 /6 N suffix on the catalog number indicates NEMA bolt hole spacing of /4. 8 Southland Road, Ormond Beach, FL 74 Telephone:

23 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Mechanical Lugs Dual-rated File E50999 File LR 5607 Figure Figure Figure Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 AX & AQ SERIES - FOR PANELBOARD Catalog Figure AX AQ -600 A-L SERIES - WITH LOCKING FEATURE CLA SERIES - LAY-IN TYPE Conductor Range # Bolt Size Dimensions (inches) Height Width Length /6 /8 / AQ /0 / AQ -800 * /8 807 AQ # / 4 5/ AQ /0 5/ Lbs Per 00 Pcs AQ # / AQ /0 5/ Figure Bolt Dimensions (inches) Lbs Per Catalog Conductor Range Size Height Width Length 00 Pcs A 5 L /0 - #4 /4 /6 5/8 5/ A 50 L /0 - #4 /4 /6 5/8 5/ A 00 L 65 V 00 - # A 50 L 50 - #6 5/6 /8 7/ A 600 CT-L & 50 - # 9/6 5/6 /8 / A 600 L # AD 600 L 7 / 9/6 /8 / Figure Bolt Dimensions (inches) Lbs Per Catalog Conductor Range Size Height Width Length 00 Pcs CLA 70-9 #4 - #4 #0 /4 5/64 5/ CLA /0 - #8 /4 7/64 9/64 / CLA #6 5/6 45/64 /6 / * Not UL listed. Not CSA listed. Southland Road, Ormond Beach, FL 74 Telephone:

24 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Neutral Bar Assemblies Dual-rated File E50999 ANA SERIES Catalog Conductor Range # Circuit Dimensions (inches) Bolt Size Connector Circuit Taps Taps Height Width Length ANA / ANA ANA #6 #8 - #4 0 /6 9/6 4 /8 / ANA / ANA / Lbs Per 00 Pcs. Aluminum Tin-Plated Splices/Reducers Dual-rated, with center cable stop File E50999 File LR 5607 BA Series US Series BA & US SERIES Dimensions (inches) Lbs Per Catalog Conductor Range Width Length 00 Pcs BA 70- * # - #4 5/ / BA 00- * /0 - #4 5/6 6. 9/ BA 50- * /0 - #4 / BA #6 /6 / BA #6 / US #6 /8 9/ US /0 /64 4 / US / 6 / US / 7 / 68.7 * Slotted screw Not CSA listed. 0 Southland Road, Ormond Beach, FL 74 Telephone:

25 Aluminum Mechanical Pedestal Connectors

26

27 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Set Screw Bar Pedestal Connectors Dual-rated ABC SERIES - IN-LINE BAR Catalog ABC 40 Conductor Range # Outlets Boot ABC 40 BB ABC ABC 540 # ABC BB ABC ABC BB 6085 ABC ABC 50 BB ABC ABC 550 # ABC BB 6085 ABC ABC BB ABC ABC 500 BB ABC ABC 5500 # BB 0500 ABC BB ABC ABC BB ABC 750 BB ABC ABC BB 6086 ABC 5750 / BB 6086 ABC BB ABC ABC BB Add suffix SL to catalog number (e.g. ABC 40 SL) for streetlight outlet (#4 Str. - #4 Sol.), and add $4.59 to the price. A longer insulating cover may be required for streetlight outlet. Add suffix C to catalog number (e.g. ABC 40 SLC) for oxide inhibitor, and add cents per cable port to the price. Insulating boot sold separately. Please refer to page 5. Southland Road, Ormond Beach, FL 74 Telephone:

28 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Set Screw Bar Pedestal Connectors Dual-rated ABC SERIES - DOUBLE ROW BAR Catalog ABC 40- Conductor Range # Outlets ABC 40- # Boot BB ABC FB ABC ABC 50- # ABC ABC ABC 500- # ABC ABC ABC 750- / ABC BB7 4 FB Special order Add suffix SL to catalog number (e.g. ABC 40- SL) for streetlight outlet (#4 Str. - #4 Sol.), and add $4.59 to the price. A longer insulating cover may be required for streetlight outlet. Add suffix C to catalog number (e.g. ABC 40- SLC) for oxide inhibitor, and add cents per cable port to the price. Insulating boot sold separately. Please refer to page 5. 4 Southland Road, Ormond Beach, FL 74 Telephone:

29 Aluminum Mechanical Transformer Connectors 5

30 6

31 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Quick Disconnect Transformer Connectors Dual-rated ABW SERIES - IN-LINE BAR Catalog Conductor Range # Outlets 6096 ABW ABW ABW ABW 540 # ABW ABW Stud Size 5/8 Boot SB 7 SB ABW SB ABW ABW ABW SB ABW ABW # / ABW SB ABW ABW SB 4 5/ ABW SB ABW ABW ABW 500 SB ABW SB ABW 5500 # SB ABW ABW SB ABW SB ABW 750 SB ABW 750 SB ABW SB ABW 5750 / SB ABW ABW SB ABW SB Add suffix SL to the catalog number (e.g. ABW 40 SL) for streetlight outlet (#4 Str. - #4 Sol.), and add $4.59 to the price. A longer insulating cover may be required for streetlight outlet. Add suffix C to the catalog number (e.g. ABW 40 SLC) for oxide inhibitor, and add cents per cable port to the price. Insulating boot sold separately. Please refer to page 5. Southland Road, Ormond Beach, FL 74 Telephone:

32 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Quick Disconnect Transformer Connectors Dual-rated ABW SERIES - DOUBLE ROW BAR Catalog 6096 ABW 40- Conductor Range # Outlets 6096 ABW 40- # ABW ABW ABW 50- # Stud Size 5/8 Boot SB ABW SB ABW ABW 500- # ABW ABW ABW 750- / SB 5 SB ABW SB Add suffix SL to the catalog number (e.g. ABW 40 SL) for streetlight outlet (#4 Str. - #4 Sol.), and add $4.59 to the price. A longer insulating cover may be required for streetlight outlet. Add suffix C to the catalog number (e.g. ABW 40 SLC) for oxide inhibitor, and add cents per cable port to the price. Insulating boot sold separately. Please refer to page 5. 8 Southland Road, Ormond Beach, FL 74 Telephone:

33 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Transformer Spade Connectors Dual-rated ABN SERIES - IN-LINE BAR Catalog Conductor Range # Outlets 6 ABN 40 6 ABN ABN ABN 540 # ABN ABN ABN ABN ABN ABN ABN 550 # ABN ABN Boot SB 7 SB SB 4 SB 7 SB SB ABN SB ABN 500 SB ABN ABN SB 649 ABN 5500 # SB ABN SB ABN SB 6 65 ABN SB 6-65 ABN ABN 750 SB ABN ABN 5750 / ABN SB ABN ABN SB Add suffix SL to the catalog number (e.g. ABW 40 SL) for streetlight outlet (#4 Str. - #4 Sol.), and add $4.59 to the price. A longer insulating cover may be required for streetlight outlet. Add suffix C to the catalog number (e.g. ABW 40 SLC) for oxide inhibitor, and add cents per cable port to the price. Insulating boot sold separately. Please refer to page 5. Southland Road, Ormond Beach, FL 74 Telephone:

34 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Transformer Spade Connectors Dual-rated Single Row Mounting Holes Double Row Mounting Holes ABT SERIES - SINGLE ROW MOUNT HOLES Catalog Conductor Range Outlets # Mount Holes 678 ABT ABT # ABT ABT ABT # ABT ABT ABT # ABT ABT SERIES - DOUBLE ROW MOUNT HOLES # Mount Catalog Conductor Range Outlets Holes 687 ABT ABT 640 # ABT ABT ABT ABT 450 # ABT ABT ABT ABT ABT # ABT ABT ABT Add suffix C to the catalog number for oxide inhibitor, and add cents per cable port to the price. Insulate with the SB series insulating boot sold separately. Please refer to page 5. 0 Southland Road, Ormond Beach, FL 74 Telephone:

35 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Transformer Spade Connectors Dual-rated, Standard NEMA Bolt Hole Spacing ABT SERIES - DOUBLE SET SCREW, DOUBLE ROW MOUNTING HOLES Catalog Conductor Range Outlets 60 ABT 500 DS # Mount Holes ABT 500 DS 4 60 ABT 4500 DS 4 6 # ABT 5500 DS ABT 6500 DS ABT 8500 DS ABT ABT ABT / ABT ABT ABT ABT ABT 6000 / ABT Add suffix C to the catalog number for oxide inhibitor, and add cents per cable port to the price. Add suffix TN to the catalog number for tin plating. Consult the factory for pricing. Insulate with the SB series insulating boot sold separately. Please refer to page 5. Southland Road, Ormond Beach, FL 74 Telephone:

36 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Transformer Spade Connectors Dual-rated ZeeBar style ZBT 50 Series Single Row Mounting Holes ZBT 50 Series Double Row Mounting Holes ZBT 750 Series ZBT 750 DS series ZBT 50 SERIES - SINGLE ROW MOUNTING HOLES Catalog Conductor Range # Outlets # Mount Dimensions (inches) Holes Length Height 6 ZBT ZBT /4 65 ZBT 0-48 # /4 66 ZBT /4 67 ZBT / ZBT 50 SERIES - DOUBLE ROW NEMA MOUNTING HOLES Catalog Conductor Range # Outlets # Mount Dimensions (inches) Holes Length Height 68 ZBT 0 69 ZBT 0 4 /4 60 ZBT 0 # /8 6 ZBT /4 6 ZBT / ZBT 750 SERIES - DOUBLE ROW NEMA MOUNTING HOLES Catalog Conductor Range # Outlets # Mount Dimensions (inches) Holes Length Height 6 ZBT 07 5/8 64 ZBT ZBT / ZBT /6 6 /8 66 ZBT / 67 ZBT /4 Lbs Per 00 Pcs. Consult factory Lbs Per 00 Pcs. Consult factory Lbs Per 00 Pcs. Consult factory ZBT-DS SERIES - TWIN SET SCREW DOUBLE ROW NEMA MOUNTING HOLES Use instead of compression lugs, easier and quicker to install. Designed for installation on NEMA bolt hole and in-line spade terminals. All outlets provided with ball bottom set screws Accepts 5/6 hex wrench. Exceeds ANSI C9.4 specifications. Consult factory for insulating boots and special applications. Catalog Conductor Range # Outlets # Mount Dimensions (inches) Holes Length Height 68 ZBT 07 DS ZBT 07 DS /6 69 ZBT 4047 DS / / 8 /8 60 ZBT 6067 DS 9 9/ 6 ZBT 8087 DS 6 4 /4 Lbs Per 00 Pcs. Consult factory Southland Road, Ormond Beach, FL 74 Telephone:

37 Insulating Boots for Pedestal & Transformer Connectors

38 4

39 TRADE PRICE SCHEDULE Effective February, 007 Insulating Boots For Transformer & Pedestal Connectors SB Series SB & SB 4 SB 6 & SB 7 BB 0 BB 7 FB FB 6 L SB SERIES - PVC TRANSFORMER BOOTS Catalog 64 SB 0 09 SB SB 44 BG 0 SB SB SB SB SB SB SB 6-09 SB 6-00 SB SB SB SB 04 SB 4 05 SB SB 7 BB SERIES - PVC PEDESTAL BOOTS Catalog 6096 BB BB 0084 BB 6097 BB 6098 BB BB BB 7 FB SERIES - EPDM RUBBER PEDESTAL BOOTS Catalog 609 FB 609 FB 6 L Southland Road, Ormond Beach, FL 74 Telephone:

40 6

41 Aluminum Compression Splices, Lugs, Tees & Pin Terminals 7

42 8

43 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Straight Splices Dual-rated, prefilled with oxide inhibitor, solid center stop, color coded end plugs File E50999 ASC-TN SERIES - STANDARD BARREL LENGTH Catalog Conductor Size Color Coded Die Set Installation Dies Designed for general application. Solid center stop assures proper cable insertion. Marked with catalog number, conductor sizes and die references. Dimensions (inches) L B Lbs Per 00 Pcs ASC 6 TN #6 Gray 9 TP, 9, 46, 6, 5/6 5/8 / ASC 4 TN #4 Green 7 TB, 7, 75, 6 7/8 7/ ASC TN # Pink 4.4 TQ, 45, 48, 6A, /, 6 5/ ASC TN # Gold ASC /0 TN /0 Tan 50 TU, BG, 8A, 5/8, 5, 4 / ASC /0 TN /0 Olive 54 TWTY, 97, 9A, 5/8-, 58 5/6 / ASC /0 TN /0 Ruby 6 0A, 77, 66, 47 5/8 / ASC 4/0 TN 4/0 White 66 TX, 98, A, 840, 7H /4 5/ ASC 50 TN 50 Red 7 TX, A, 840, 76, 49 5/6 / ASC 00 TN 00 Blue 76 TH, A, 87H, 5 /8 5/ ASC 50 TN 50 Brown 87 96, 99, A, 94H /8 9/ ASC 400 TN 400 Green 94 96, A, 655, 99H /4 5/ ASC 500 TN 500 Pink 99 06A, 4A, 00, 7 7/8 7/ ASC 600 TN 600 Black 06 5H, 47, 786, 96, H 4 /8 5/ ASC 750 TN 750 Yellow 5 40H, 0 4 5/8 / ASC 800 TN 800 Gray 40 40H, /4 / ASC 000 TN 000 Brown 6 0, 6 5 /4 / ASC 50 TN 50 Brown 6, 77, 5, 7/8 8 / ASC 500 TN 500 Blue 478, 89 6 / / ASC 000 TN 000 Red 75, 4 7 / 9/ Southland Road, Ormond Beach, FL 74 Telephone:

44 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Straight Splices Dual-rated, prefilled with oxide inhibitor, solid center stop, color coded end plugs File E50999 Designed for general application. Solid center stop assures proper cable insertion. Marked with catalog number, conductor sizes and die references. AC-TN SERIES - LONG BARREL LENGTH Catalog Conductor Size Color Coded Die Set Installation Dies Dimensions (inches) L B Lbs Per 00 Pcs AC 4 TN #4 Green 7 TB, 7, 75, 6 /8 7/ AC TN # Pink 4 7. TQ, 45, 48, 6A, / / 5/ AC TN # Gold AC /0 TN /0 Tan 50 TU, BG, 8A, 5/8, 5, 4 7/6 9.6 /6 68 AC /0 TN /0 Olive 54 TWTY, 97, 9A, 5/8-, 58 / AC /0 TN /0 Ruby 6 0A, 77, 66, 47 5/6 / AC 4/0 TN 4/0 White 66 TX, 98, A, 840, 7H 4 /6 7/ AC 50 TN 50 Red 7 TX, A, 840, 76, 49 5 /6 7/ AC 00 TN 00 Blue 76 TH, A, 87H, 5 5 /6 / AC 50 TN 50 Brown 87 96, 99, A, 94H 6 5/8 / AC 400 TN 400 Green 94 96, A, 655, 99H 7 7/ 7/ AC 500 TN 500 Pink 99 06A, 06, 4A, 00, 7 7 7/ 5/ AC 600 TN 600 Black 06 5H, 47, H 7 5/ / AC 750 TN 750 Yellow 5 40H, 0 8 9/ AC 800 TN 800 Gray 40 40H, /6 4 / AC 000 TN 000 Brown 6 0, 6 9 7/8 4 / AC 50 TN 50 Brown 6, 5, /8-684 AC 500 TN 500 Blue 478, 89 6 / AC 750 TN 750 White 04, 79, 40AH 5 6 5/6-686 AC 000 TN 000 Red 75, / Southland Road, Ormond Beach, FL 74 Telephone:

45 TRADE PRICE SCHEDULE Effective February, 007 Aluminum High Voltage Tapered Splices Dual-rated, prefilled with oxide inhibitor, solid center stop, color coded end plugs, rated up to 69 KV* ATC SERIES Catalog Conductor Size Color Coded Die Set Installation Dies 060 ATC 4 #4 Green 7 75, 6, /8, 7 /4 Dimensions (inches) 06 ATC # Pink 4 48, 6A, TQ, 45 /6 9/ ATC # Tan 50 4, 96, 5/8, 8A, 49 / ATC /0 /0 Tan 50 4, 8A, TU, 5 L 064 ATC /0 /0 Olive 54 45, 9A, TWTY, 58 /6 7/ ATC /0 /0 Ruby 6 47, 0A, TV, ATC 4/0 4/0 White 66 98, A, TX, 7.8 / /4 067 ATC Red 7 49, A, TX, ATC Blue 76 5, A, TH, 87 / / ATC Brown 87 99, A, 96 9/ ATC Green 94 47, A, / 9/ ATC Pink 99 00, 4A, 06, 7 5 / / ATC Black 06 47, 5 6 / / ATC Red 5 0, / / ATC , 474, 4, 0, / 7 5/6 5/8-064 ATC Brown 6 0, 6 8 7/ 4 / ATC Brown 6, 5, 579, 0AH 9 /4 4 5/8-609 ATC Blue 478, 89R, L46, ART 9 /4 4 5/ ATC White 89, 78, 8AH / 5 / ATC Red 89, 478, 78 7/8 5 /6 - B Solid center stop assures proper cable insertion. For use on all non-tension Aluminum/Aluminum or Aluminum/Copper reducer joints to 69KV. End taper is positive identification of high voltage heavy duty application. Marked with catalog number, conductor sizes and die references. L B Lbs Per 00 Pcs * For high voltage applications, refer to the cable manufacturer. Add suffix TN to the catalog number for tin-plating. Consult the factory for pricing. Southland Road, Ormond Beach, FL 74 Telephone:

46 TRADE PRICE SCHEDULE Effective February, 007 Aluminum High Voltage Tapered Reducing Splices Dual-rated, prefilled with oxide inhibitor, solid center stop, color coded end plugs, rated up to 69 KV* ATC-R SERIES Catalog Conductor Size From To Color Coded Die Set 464 ATC R 4 # #4 Pink 4-46 ATC /0 R # 7. /0 Tan ATC /0 R 4 #4-408 ATC /0 R /0 /0 8.0 / ATC /0 R # - 04 ATC /0 R /0 / ATC 4/0 R /0 /0 White 66 Lbs Per 00 pcs ATC 4/0 R /0 4/0 / ATC 4/0 R # ATC 50 R /0 50 /0 Red ATC 50 R 000 ATC 50 R /0 / ATC 50 R /0 /0-50 Brown ATC 50 R /0 /0-000 ATC 50 R 4/0 4/ ATC 50 R ATC 500 R 600 ATC 500 R /0 / ATC 500 R /0 / ATC 500 R 4/ /0 Pink ATC 500 R ATC 500 R ATC 500 R ATC 750 R 758 ATC 750 R /0 / ATC 750 R 4/ /0 Red ATC 750 R ATC 750 R ATC 000 R Brown ATC 000 R # # # Solid center stop assures proper cable insertion. For use on all non-tension Aluminum/Aluminum or Aluminum/Copper reducer joints to 69KV. End taper is positive identification of high voltage heavy duty application. Marked with catalog number, conductor sizes and die references * For high voltage applications, refer to the cable manufacturer. 4 Southland Road, Ormond Beach, FL 74 Telephone:

47 TRADE PRICE SCHEDULE Effective February, Aluminum Tin-Plated One Hole Lugs Dual-rated, prefilled with oxide inhibitor, color coded end plugs File E50999 AL-TN SERIES - TIN-PLATED Conductor Color Coded Bolt Dimensions (inches) Lbs Per Catalog Installation Dies Size Die Set Size L B P W 00 Pcs. 750 AL 6-4 TN #6 Gray 9 5/6, 46, TP /4 5/ /6 7/8 9/ AL 4-56 TN 5/6 - #4 Green 7 75, TB 75 AL 4-4 TN.8 /4 / / 75 AL -4 TN 4. # Pink 4 / 6009 AL -8 TN - /, 48, TQ 7505 AL -4 TN 4.9 # Gold 45 /8 / AL -8 TN AL /0-8 TN 6.9 /0 Tan 50 5/8, BG, TU /4 7/8 47 AL /0-48 TN / - /6 / AL /0-8 TN /8 7. /0 Olive 54 5/8-, 97, TWTY /8 5/ AL /0-48 TN / AL /0-8 TN /8 9.6 /0 Ruby 6 77, 467 7/6 /6 44 AL /0-48 TN / - / AL 4/0-8 TN /8.6 4/0 White , 98, TX 9/6 /6 00 AL 4/0-48 TN 5/ AL TN 50 Red 7H 840, 4, TX 5/8 5/8 / AL TN 00 Blue 76H, 470, TH / 4 /8.5 /4 445 AL TN 50 Brown 87H -/8, 99, 96 4 /4 / AL TN Green 94H -/8, 47, /8 / /4 5/ AL TN 5/8-600 AL TN / Pink 99H -5/6, 00, 06A /4 600 AL TN 5/8 5 7/6 / AL TN / Black 06H -5/6, 47, 5H 5/6 760 AL TN 5/8 5 /6 /6 9/ AL TN / Red -/, 0, 40H 6 / / AL TN 5/8 80. / AL TN - / /, 474, 40H 6 5/8 7/8 /6 766 AL TN - 5/8-767 AL TN / Brown 6 -/4, 75, 50H 7 7/8 4 5/8 9/6 768 AL TN 5/ Southland Road, Ormond Beach, FL 74 Telephone:

48 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Two Hole NEMA Lugs Dual-rated, prefilled with oxide inhibitor, color coded end plugs File E50999 AL-NTN SERIES- STRAIGHT LUG Catalog Conductor Size Color Coded Die Set Installation Dies Bolt Size Lbs Per 00 Pcs. Std.Ctn SA 6 NTN # SA 4 NTN #4 5.0 Tan 50 5, BG, 4, 5/ SA NTN # AL /0 NTN / AL /0 NTN /0 Olive 54 58, 97, 45, 5/ AL /0 NTN /0 Ruby 6 66, 67, 47, AL 4/0 NTN 4/0 White , 98, TX AL 50 NTN 50 Red 7 840, 4, TX AL 00 NTN 00 Blue 76 87H, 470, 5, AL 50 NTN 50 Brown 87 96, 99, 655, -/ / 4055 AL 400 NTN 400 Green 94 96, 47, 705, -/ AL 500 NTN 500 Pink 99 06A, 00, 46, -5/ AL 600 NTN 600 Black 06 5H, 47, 786, -5/ AL 750 NTN 750 Yellow 5 40H, 0, 4, -/ AL 800 NTN 800 Gray 40 40H, 474, 74, -5/ AL 000 NTN 000 Brown 6 6, 0, 77, -/ AL 50 NTN 50 Brown -7/8, AL 500 NTN 500 Blue AL 750 NTN 750 White 04, 79, 40AH AL 000 NTN 000 Red Southland Road, Ormond Beach, FL 74 Telephone:

49 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Two Hole NEMA Lugs Dual-rated, prefilled with oxide inhibitor, color coded end plugs File E50999 ASL-NTN SERIES - STACKING LUG Catalog Conductor Size Color Coded Die Set Installation Dies Bolt Size 506 ASL 6 NTN # ASL 4 NTN #4 5.0 Tan 50 5, BG, 4, 5/8 407 ASL NTN # ASL /0 NTN / ASL /0 NTN /0 Olive 54 58, 97, 45, 5/ ASL /0 NTN /0 Ruby 6 66, 67, 47, ASL 4/0 NTN 4/0 White , 98, TX ASL 50 NTN 50 Red 7 840, 4, TX ASL 00 NTN 00 Blue 76 87H, 470, 5, ASL 50 NTN 50 Brown 87 96, 99, 655, -/ / 4076 ASL 400 NTN 400 Green 94 96, 47, 705, -/ ASL 500 NTN 500 Pink 99 06A, 00, 46, -5/ ASL 600 NTN 600 Black 06 5H, 47, 786, -5/ ASL 750 NTN 750 Yellow 5 40H, 0, 4, -/ ASL 800 NTN 800 Gray 40 40H, 474, 74, -5/ ASL 000 NTN 000 Brown 6 6, 0, 77, -/ ASL 50 NTN 50 Brown -7/8, ASL 500 NTN 500 Blue ASL 750 NTN 750 White 04, 79, 40AH ASL 000 NTN 000 Red Lbs Per Std.Ctn. 00 Pcs Southland Road, Ormond Beach, FL 74 Telephone:

50 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Four Hole NEMA Lugs Dual-rated, prefilled with oxide inhibitor, color coded end plugs AL 4 NTN SERIES Catalog Conductor Size 765 AL NTN AL NTN AL 50-4 NTN 50 4 AL NTN AL NTN AL NTN AL NTN 500 Bolt Size / Lbs Per 00 Pcs. Consult factory Std.Ctn. 46 Southland Road, Ormond Beach, FL 74 Telephone:

51 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Meter Socket Lugs Common Die Series Dual-rated, prefilled with oxide inhibitor Designed for meter pan and general application. Entire conductor range installed with one die. Marked with catalog number, conductor sizes and die references. SAKM SERIES Conductor Size Catalog Concentric Compressed Compact Solid 064 SAKM 6-48 #6 #6 #6 #4 064 SAKM 4-48 #4 #4 #4 # 064 SAKM -48 # # # & # # 0644 SAKM -48 # # /0 / SAKM /0-48 /0 /0 /0 / SAKM /0-48 /0 /0 /0 / SAKM /0-48 /0 /0 4/ SAKM 4/0-48 4/0 4/ SAKM SAKM SAKM * SAKM 6-8 #6 #6 #6 #4 066 SAKM 4-8 #4 #4 #4 # 066 SAKM -8 # # # & # # 066 SAKM -8 # # /0 /0 065 SAKM /0-8 /0 /0 /0 /0 060 SAKM /0-8 /0 /0 /0 /0 06 SAKM /0-8 /0 /0 4/ SAKM 4/0-8 4/0 4/ SAKM SAKM 50-8 * Bolt Size / /8 Lbs. Per 00 Pcs. Consult factory * For aluminum conductors only. Add suffix TN to the catalog number for tin-plating. Consult the factory for pricing. Southland Road, Ormond Beach, FL 74 Telephone:

52 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated Meter Socket Lugs - Star Hole Dual-rated, prefilled with oxide inhibitor MSL SERIES Catalog Conductor Size 0647 MSL 4 #4 Str. Cpt. Sol MSL # Str. Cpt. Sol MSL /0 /0 Str. Cpt. 065 MSL /0 /0 Str. Cpt. 065 MSL /0 /0 Str. Cpt. 065 MSL 4/0 4/0 Str. Cpt MSL Str. Cpt MSL Str. Cpt MSL Str. Cpt MSL Str MSL Str. Lbs Per 00 Pcs. Consult factory Southland Road, Ormond Beach, FL 74 Telephone:

53 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tin-Plated High Voltage Tapered Lugs Dual-rated, prefilled with oxide inhibitor, color coded end plugs, rated up to 69 KV* AL-TNV SERIES - ONE HOLE One Hole Catalog Conductor Size Two Hole Color Coded Die Set Lbs Per 00 Pcs AL 4-8 TNV #4 Gray AL -8 TNV # Brown AL -8 TNV # Green AL /0-8 TNV /0 Pink AL /0-48 TNV /0 Black AL /0-48 TNV /0 Orange AL 4/0-48 TNV 4/0 Purple AL TNV 50 Yellow AL TNV 00 White AL TNV 50 Red AL-NTNV SERIES - TWO HOLE Catalog Conductor Size Color Coded Die Set Lbs Per 00 Pcs. 060 AL /0 NTNV /0 Pink AL /0 NTNV /0 Black AL /0 NTNV /0 Orange AL 4/0 NTNV 4/0 Purple AL 50 NTNV 50 Yellow AL 00 NTNV 00 White AL 50 NTNV 50 Red AL 500 NTNV 500 Brown AL 750 NTNV 750 Black AL 000 NTNV 000 White End taper is positive identification of high voltage heavy duty application. Marked with catalog number, conductor sizes and die references * For high voltage applications, refer to the cable manufacturer. Southland Road, Ormond Beach, FL 74 Telephone:

54 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tees Dual-rated, prefilled with oxide inhibitor Designed for general application. Available in many main and tap sizes. End taper is positive identification of high voltage heavy duty application. Marked with catalog number, conductor sizes and die references. AT SERIES Meets or exceeds Class A requirements of ANSI C9.4. Catalog Conductor Size Main Tap 09 AT -4 #4 # 07 AT - # 5 AT /0-4 #4 AT /0- /0 # AT /0-/0 /0 9 AT /0- # AT /0-/0 /0 /0 7 AT /0-/0 /0 AT /0- # 50 AT /0-/0 /0 /0 7 AT /0-/0 /0 9 AT 4/0- AT 4/0-/0 /0 4/0 AT 4/0-/0 /0 5 AT 4/0-4/0 4/0 40 AT 50-4 AT 50-/0 /0 4 AT 50-/0 50 /0 45 AT 50-/0 /0 46 AT AT 00-/0 5 AT 00-/0 / AT 00-4/0 4/0 /0 5 AT Catalog 55 AT 50- Conductor Size Main Tap 57 AT 50-/0 /0 59 AT 50-/0 50 /0 6 AT 50-4/0 4/0 6 AT AT 400-/0 67 AT 400-4/ /0 /0 69 AT AT 500-/0 /0 7 AT 500-4/0 4/ AT AT AT 750-/0 /0 8 AT 750-4/0 4/0 80 AT AT AT AT 000-4/0 4/0 60 AT AT AT AT Add suffix TN to the catalog number for tin-plating. Consult the factory for pricing. 50 Southland Road, Ormond Beach, FL 74 Telephone:

55 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Tapered Tees Dual-rated, prefilled with oxide inhibitor, rated up to 69 KV* ATT SERIES Catalog Conductor Size Main Tap 604 ATT -4 #4 # 605 ATT - # 606 ATT /0-4 #4 607 ATT /0- /0 # 0005 ATT /0-/0 /0 608 ATT /0- # 609 ATT /0-/0 /0 / ATT /0-/0 /0 604 ATT /0- # 604 ATT /0-/0 /0 /0 604 ATT /0-/0 / ATT 4/ ATT 4/0-/0 /0 4/ ATT 4/0-/0 / ATT 4/0-4/0 4/ ATT ATT 50-/0 / ATT 50-/0 50 /0 605 ATT 50-/0 /0 605 ATT ATT 00-/ ATT 00-/0 / ATT 00-4/0 4/0 / ATT Catalog 0007 ATT 50- Conductor Size Main Tap 6057 ATT 50-/0 / ATT 50-/0.50 / ATT 50-4/0 4/ ATT ATT 400-/0 606 ATT 400-4/ /0 /0 606 ATT ATT 500-/0 / ATT 500-4/0 4/ ATT ATT ATT 750-/0 / ATT 750-4/0 4/0 00 ATT ATT ATT ATT 000-4/0 4/ ATT ATT ATT ATT ATT * For high voltage applications, refer to the cable manufacturer. Add suffix TN to the catalog number for tin-plating. Consult the factory for pricing. Southland Road, Ormond Beach, FL 74 Telephone:

56 TRADE PRICE SCHEDULE Effective February, 007 Bi-Metallic Compression Pin Terminals Aluminum body, tin-plated stranded copper pin, prefilled with oxide inhibitor, complete with insulating cover File E50999 For application in meter pans and in other metal enclosed gear to convenience wiring where clearances are minimal. Marked with catalog number, conductor sizes and die references. Consult the factory for additional pin lengths and offset pin styles. BMS SERIES Catalog Conductor Size CU Pin BMS 6 C #6 # BMS 4 C #4 #6 468 BMS C # & # # BMS C # # 466 BMS /0 C /0 # 467 BMS /0 C /0 # 0085 BMS /0 C /0 /0 469 BMS 4/0 C 4/0 / BMS 50 C 50 / BMS 00 C BMS 50 C 50 4/ BMS 400 C BMS 500 C BMS 600 C BMS 750 C To order without the insulating cover, delete suffix C from the catalog number. 5 Southland Road, Ormond Beach, FL 74 Telephone:

57 Aluminum Compression Service Entrance Splices, H-Tap Connectors & Covers 5

58 54

59 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Service Entrance Compression Splices - 5/8 Die Series Prefilled with oxide inhibitor SHURESplice U N SERIES - INSULATED, LONGER LENGTH 0659 U N 88 Green #6 #8 Green #6 # U N 8 Brown #8 #0-445 U N 66 Blue #4 #5 & #6 6-6/ 4595 U N 68 Blue #4 #5 & #6 6-6/ Green #6 #8 459 U N 6 Brown #8 #0-44 U N 44 Orange # # & #4 4-6/, 7/ 444 U N 46 Blue #4 #5 & #6 6-6/ Orange # # & #4 4-6/, 7/ 459 U N 48 Green #6 #8-80 U N 4 Brown #8 #0 440 U N Red # # & # -6/, 7/ 44 U N 4 Orange # # & #4 4-6/, 7/ 44 U N 6 Red # & # -6/, 7/ Blue #4 #5 & #6 6-6/ 805 U N 8 Green #6 #8-067 U N Brown #8 #0 # 4407 U N 00 Yellow - /0 /0-6/ 4408 U N 0 Red # # & # - 6/ 4409 U N 04 Yellow /0 /0-6/ Orange # # & #4 4-6/ 885 U N 06 Blue #4 #5 & #6 6-6/ 0677 U N 08 Green #6 #8 - U B SERIES - UNINSULATED Catalog Catalog Conductor A Conductor B Color Solid Stranded ACSR Color Solid Stranded ACSR Conductor A Conductor B Color Solid Stranded ACSR Color Solid Stranded ACSR Green #6 #8 - Green #6 # U B U B 8 Brown #8 # U B 66 Blue #4 #5 & #6 6-6/ 0560 U B 68 Blue #4 #5 & #6 6-6/ Green #6 # U B 6 Brown #8 # U B 44 Orange # # & #4 4-6/, 7/ 0556 U B 46 Blue #4 #5 & #6 6-6/ Orange # # & #4 4-6/, 7/ 0557 U B 48 Green #6 # U B 4 Brown #8 # U B Red # # & # -6/, 7/ 055 U B 4 Orange # # & #4 4-6/, 7/ 055 U B 6 Red # & # -6/, 7/ Blue #4 #5 & #6 6-6/ 055 U B 8 Green #6 # U B Brown #8 #0 # 0564 U B 00 Yellow - /0 /0-6/ 056 U B 0 Red # # & # - 6/ 054 U B 04 Yellow /0 /0-6/ Orange # # & #4 4-6/ 054 U B 06 Blue #4 #5 & #6 6-6/ 056 U B 08 Green #6 # / Southland Road, Ormond Beach, FL 74 Telephone:

60 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Insulated Service Entrance Compression Splices - 5/8 Die Series Prefilled with oxide inhibitor SHURESplice U SERIES FOR COMPACT CONDUCTORS - LONGER LENGTH Catalog U SERIES - STANDARD LENGTH Conductor A Conductor B Std.Ctn. Color Stranded Compact Compr. Color Stranded Compact Solid Compr. Brown #0 - #8 - #6 #6 #6 Blue 646 U 6 BBR 647 U 68 BG Green #8 #8 - #8 648 U 66 BB Blue #6 #6 - #6 649 U 4 OBR Brown #0 - #8-640 U 48 OG #4 #4 #4 Green #8 #8 - #8 Orange 64 U 46 OB Blue #6 #6 - #6 64 U 44 OO Orange #4 #4 - #4 64 U RBR Brown #0 - #8-644 U 8 RG Green #8 #8 - #8 645 U 6 RB Red # # # Blue #6 #6 - #6 646 U 4 RO Orange #4 #4 - #4 647 U RR Red # # - # 648 U 0 YBR Brown #0 - #8-649 U 08 YG Green #8 #8 - # U 06 YB Blue #6 #6 - #6 Yellow /0 /0 /0 644 U 04 YO Orange #4 #4 - #4 644 U 0 YR Red # # - # 644 U 00 YY Yellow /0 /0 - /0 00 /4 Catalog Conductor A Conductor B Color Solid Stranded ACSR Color Solid Stranded ACSR Green #6 #8 - Brown #8 #0 Brown #8 #0 - Blue #4 #6 # UGBR UGG 88 Green #6 # UBBR 6 07 UBG 68 Green #6 #8 07 UBB 66 Blue #4 #6 # UOBR 4 Brown #8 #0-07 UOG 48 Green #6 #8 Orange # #4 #4 070 UOB 46 Blue #4 #6 # UOO 44 Orange # #4 # URBR Brown #8 # URG 8 Green #6 # URB 6 Red # & # # Blue #4 #6 # URO 4 Orange # #4 # URR Red - # & # # UYG 08 Green #6 #8-070 UYB 06 Blue #4 #6 #6 070 UYO 04 Yellow /0 /0 Orange # #4 #4 070 UYR 0 Red # & # # UYY 00 Yellow /0 / / 56 Southland Road, Ormond Beach, FL 74 Telephone:

61 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Uninsulated Service Entrance Compression Splices - / Die Series Prefilled with oxide inhibitor SHURESplice Q U SERIES Catalog Conductor A Conductor B Color Solid Stranded ACSR Color Solid Stranded ACSR Green #6 #8 - Green #6 #8-07 Q U 5 07 Q U 5 Brown #8 #0 970 Q U 54 Blue #4 #5 & #6 6-6/ 4487 Q U 55 Blue #4 #5 & #6 6-6/ Green #6 #8 075 Q U 56 Brown #8 # Q U 57 Orange # # & #4 4-6/, 7/ 4489 Q U 58 Blue #4 #5 & #6 6-6/ Orange # # & #4 4-6/, 7/ 4490 Q U 59 Green #6 #8-079 Q U 60 Brown #8 #0 449 Q U 65 Red # # & # -6/, 7/ 449 Q U 67 Orange # # & #4 4-6/, 7/ Red # # & # -6/, 7/ 449 Q U 68 Blue #4 #5 & #6 6-6/ 4494 Q U 69 Green #6 # Southland Road, Ormond Beach, FL 74 Telephone:

62 TRADE PRICE SCHEDULE Effective February, 007 Aluminum H-Type Compression Connectors Prefilled with oxide inhibitor Groove C Style Style Style Style 4 Style 5 Style 6 Style 7 Style 8 Catalog Style # Tap Cover Groove A Conductor Range Groove B ACSR Str. Solid Metric Metric mm ACSR Str. Solid mm Lbs Per 00 Pcs. 44 UB 4 7 #-#6 #-#6 #-# #8-#4 #7-# OB 04 8 /0-# /0-# OB 44 4 #-#6 #-#6 #-#6 #-#6 8.0 #-#6 #-# OB 6 #-#6 #-# OB 0 4 /0-# /0-# # 50-5 #-#6 #-#6 8. #-#6 406 OB 0 /0-#6 /0-#6 #-# CO 0 B OB 00 /0-#4 /0-#4 # 50-5 /0-#4 /0 # DB 0 4 #-#6 #-#6 #-# /0-# /0-/ DB 00 /0-# /0-# DB CO 40 B #-#6 #-#6 #-# DB 400 4/0-/0 4/0-/ /0-# /0-# DB /0-/0 4/0-/ NB NB NB ZB ZB CN 600 B - 477(8/) - 4/0 (6/) 500-4/0 477(8/) 40-4/0 (6/) 500-4/ (8/) /0 4/0-/0 4/0-/ /0 (6/7) 556.5(4/7) 66.8(8.) /0 (7/) #6 (6/) /0 /0-6 /0-# / ZB /0-/0 4/0-/ C Groove = (6/) ACSR, #-#6 Str., #-#6 Sol.,.6-.6 mm 5-0, Compressed Conductors = #-#6 ACSR, #-#6 Str. Compact Conductor Sizes: Groove A: ACSR, Str. Groove B: 66-/0 ACSR, 66-/0 Str. C Groove = #8 Str.-#4 Sol., in. dia., 6-.5 mm Please refer to the next page for tap cover information. 58 Southland Road, Ormond Beach, FL 74 Telephone:

63 TRADE PRICE SCHEDULE Effective February, 007 H-Type Connector Covers Fabricated from UV-resistant black polypropylene W L H Dimensions (inches) Lbs Per Catalog Height Width Length 00 Pcs. 48 CO 0 B /4 4 / 5/ CD 40 B /8 5 5/8 / CN 600 B 5/6 6 7/8 / Southland Road, Ormond Beach, FL 74 Telephone:

64 60

65 Copper Mechanical Connectors Lugs Splices Neutral Bar Assemblies 6

66 6

67 TRADE PRICE SCHEDULE Effective February, 007 Copper Mechanical Lugs For installation on copper conductor File E50999 File LR 5607 ML Series ML SERIES - ONE BARREL ONE HOLE CP- Series Dimensions (inches) Bolt Lbs Per Catalog Conductor Range Height Tang Width Tang Thickness Length Size 00 Pcs ML 8 #8 - #4 /8 /8 5/64 /6 / ML 4 #4 - #4 7/ / / /8 / ML /0 * /0 - #8 /4 /4 / / 5/ ML 50 * 50 - #6 /6 5/6 /8 5/6 / CP- SERIES - ONE BARREL TWO HOLE STRAIGHT TANG Amp Dimensions (inches) Bolt Catalog Conductor Range Rating Height Tang Width Length Size 6754 CP 5- #4 - /0 5 /6 /4 / 7/ CP 50- # / CP 600- / / /4 7/8 /6 00% conductivity for highest efficiency. One piece, flat bottom design,for full contact. Completely re-usable. Marked with catalog number and conductor range. Requires no special installation tools. Lbs Per 00 Pcs. Consult factory Slotted screw * /4 hex Add suffix TN to the catalog number for tin-plating. Consult the factory for pricing. Not CSA listed. Southland Road, Ormond Beach, FL 74 Telephone:

68 TRADE PRICE SCHEDULE Effective February, 007 Copper Mechanical Lugs For installation on copper conductor File E50999 File LR 5607 Amp Dimensions (inches) Bolt Lbs Per Catalog Conductor Range Rating Height Tang Width Length Size 00 Pcs CS 5 #0 - #4 5 5/8 5/6 /64 / CS 5 #6 - #4 & Comb. 50 /6 /8 9/64 / CSA 70 #4 - #4 70 7/8 /4 0.7 / 86 CS 70 # - #8 & Comb. 90 5/ / CS 5 /0 - # 5 /4 5/8 5/ CS 75 /0 - #4 75 9/6 /4 /6 / CS 5 4/0 - # 5 /6 /8 5/ CS /0 00 /8 / / CS / /6 / 7/ CS /6 5 /8 / 75.0 CX SERIES - ONE BARREL ONE HOLE STRAIGHT FIXED TANG Amp Dimensions (inches) Bolt Lbs Per Catalog Conductor Range Rating Height Tang Width Length Size 00 Pcs CX 5 #6 - #4 50 /4 /8 / CX 70 #4 - #4 & Comb. 70 5/8 / /4. / CX 5 /0 - #4 & Comb. 5 5/8 9/ CX 5 4/0 - # 5 5/8 /6 5/ CX / /6 / /6 / CD SERIES - ONE BARREL TWO HOLE STRAIGHT TANG 00% conductivity for highest efficiency. Completely re-usable. Marked with catalog number and conductor range. Requires no special installation tools. Available in plain copper finish, or, upon special CS Series CX Series CD Series request, with tin or silver plating. CS SERIES - ONE BARREL ONE HOLE STRAIGHT TANG Amp Dimensions (inches) Bolt Lbs Per Catalog Conductor Range Rating Height Tang Width Length Size 00 Pcs CD 5 #6 - #4 & Comb. 50 /6 /8 /6 / CD 70 # - #8 & Comb. 90 / 5/6 5.0 / CD 5 /0 - # 5 /4 5/8 / CD 5 4/0 - # 5 /6 5/8 5/ CD /0 00 5/8 5 / / CD / /6 / CD /6 6 /8 /.0 Slotted screw. Add suffix TN to the catalog number for tin-plating. Consult the factory for pricing. 64 Southland Road, Ormond Beach, FL 74 Telephone:

69 TRADE PRICE SCHEDULE Effective February, 007 Copper Mechanical Lugs For installation on copper conductor File E50999 File LR 5607 CB Series CO Series DC Series CB SERIES - ONE BARREL ONE HOLE OFFSET TANG Amp Dimensions (inches) Bolt Lbs Per Catalog Conductor Range Rating Height Tang Width Length Size 00 Pcs. 888 CB 5 #0 - #4 5 /6 5/6 / CB 5 #6 - #4 & Comb. 50 /4 /8 /6 / CBA 70 #4 - #4 70 /6 5/6.9 / 8997 CB 70 # - #8 & Comb. 90 7/ / CB 5 /0 - # 5 /8 5/8 / CB 75 /0 - #4 75 9/6 /4 /6 / CB 5 4/0 - # 5 5/8 5/ CB /0 00 5/8 / / CB /0 400 /4 / 4 / CB /6 4 5/8 / 90.0 CO SERIES - ONE BARREL TWO HOLE OFFSET TANG Amp Dimensions (inches) Bolt Lbs Per Catalog Conductor Range Rating Height Tang Width Length Size 00 Pcs. 807 CO 5 #6 - #4 & Comb. 50 /4 /8 /6 / CO 70 # - #8 & Comb. 90 / 5/6 5.0 /4 45 CO 5 /0 - # 5 /8 5/8 / CO 5 4/0 - # 5 /6 5/8 5/ CO /0 00 5/8 5 / /8 55 CO /0 400 /4 / CO /6 6 /8 /.0 DC SERIES - TWO BARREL ONE HOLE OFFSET TANG * 00% conductivity for highest efficiency. Completely re-usable. Marked with catalog number and conductor range. Requires no special installation tools. Available in plain copper finish, or, upon special request, with tin or silver plating. Amp Dimensions (inches) Bolt Lbs Per Catalog Conductor Range Rating Height Tang Width Length Size 00 Pcs DC 450 4/0 - #6 450 / / / DC /0 600 /4 /4 5/ DC / /6 4 7/6 / Slotted screw * Not CSA Listed. Southland Road, Ormond Beach, FL 74 Telephone:

70 TRADE PRICE SCHEDULE Effective February, 007 Copper Mechanical Splices For installation on copper conductor CBS SERIES Catalog Conductor Range Lbs Per 00 Pcs CBS # - # Str CBS /0 #4 - /0 Str CBS 4/0 # - 4/0 Str Copper Neutral Bar Assemblies For installation on copper conductor NBL SERIES Conductor Range # Circuit Catalog Bolt Size # Mount Dimensions (inches) Connector Circuit Taps Taps Holes Height Width Length 000 NBL 40 4 /8 5 /8 5/6 00 NBL 00 0 / #0-5/6 4 / #6-50 #4 - #6 004 NBL 60 6 /4 tapped 5 /8 holes 00 NBL /6 7/6 5 / Lbs Per 00 Pcs. Consult factory 66 Southland Road, Ormond Beach, FL 74 Telephone:

71 Copper Compression Connectors Splices Lugs Tees 67

72 68

73 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Straight Splices For installation on copper conductor, dimpled center stop File E50999 File LR 5607 SC SERIES - STANDARD BARREL LENGTH Catalog Conductor Size Color Coded Die Set Dimensions (inches) L B Lbs Per 00 Pcs SC 0 #0 - /4 /8. 8 SC 8 #8 Red /6 7/ SC 6 #6 Blue 4. /4 / SC 4 #4 Gray SC # Brown SC # Green 7 7/8 7/ SC /0 /0 Pink SC /0 /0 Black 45 5/ SC /0 /0 Orange 50 8 / SC 4/0 4/0 Purple SC Yellow 6.8 /4 / SC White SC Red 7 /8 / SC Blue 76 / / SC Brown 87. 7/8 / SC Green SC Black 06 /8 5/ SC White 5 7/8 7/ SC Green 4 / SC Brown 4 5/8 /4 79. L B Produced from seamless electrolytic copper tubing. Dimpled center stop assures proper cable insertion. Color coded barrels are marked with catalog number, conductor sizes and die references Southland Road, Ormond Beach, FL 74 Telephone:

74 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Straight Splices For installation on copper conductor, dimpled center stop File E50999 File LR 5607 B L C SERIES - LONG BARREL LENGTH Catalog Conductor Size Color Coded Die Set Dimensions (inches) L B Lbs Per 00 Pcs C 0 #0 - /4 / C 8 #8 Red /4 / C 6 #6 Blue 4 /8.5 / C 4 #4 Gray 9 / C # Brown 5/8 / C # Green 7 / / C /0 /0 Pink 4 / C /0 /0 Black /8 / C /0 /0 Orange C 4/0 4/0 Purple /8 5/ C Yellow C White / C Red C Blue 76 4 /8 / C Brown /8 / C Green 94 5 / / C Black /8 7/ C White 5 6 / C Green 6 / / C Brown 7 5/8 7/ Southland Road, Ormond Beach, FL 74 Telephone:

75 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Straight Splices For installation on copper conductor, solid center oil-stop, color coded barrel PC SERIES Color Coded Dimensions (inches) Lbs Per Catalog Conductor Size Die Set L B 00 Pcs PC 6 #6 Blue 4.0 /8 / PC 4 #4 Gray PC # Brown 5/8 / PC # Green /8 / PC /0 /0 Pink PC /0 /0 Black /8 / PC /0 /0 Orange PC 4/0 4/0 Purple /8 5/ PC Yellow PC White / PC Red PC Blue 76 4 /8 / PC Brown /8 / PC Green 94 5 / / PC Black /8 7/ PC Orange 6 5/ PC White 5 6 /8 8.8 L B Produced from seamless electrolytic copper tubing. Silver brazed oil-stop ensures no oil seepage. Double crimp length for added mechanical strength Southland Road, Ormond Beach, FL 74 Telephone:

76 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Tapered Splices For installation on copper conductor, dimpled center stop, color coded barrel, rated up to 69 KV* L B Produced from seamless electrolytic copper tubing. Dimpled center stop assures proper cable insertion. Indents should be filled with inert material. TC SERIES - DIMPLED CENTER STOP Color Coded Dimensions (inches) Catalog Conductor Size Die Set L B 97 TC 6 #6 Blue 4 9/ 7/8 97 TC 4 #4 Gray TC # Brown TC # Green 7 /6 / TC /0 /0 Pink TC /0 /0 Black 45 7/ / TC /0 /0 Orange 50 / 8.5 /8 99 TC 4/0 4/0 Purple 54 / TC Yellow 6 9/6 7/ TC White 66 5/8 / TC Red 7 5/ 5/ TC Blue 76 / 7/ TC Brown 87 7/ / TC Green / /6 95 TC Black TC Orange 4 9/ TC White 5 4 / 7/ TC Green 6 / 7/ TC Brown 6 /6 5/ - Lbs Per 00 Pcs * For high voltage applications, refer to the cable manufacturer. 7 Southland Road, Ormond Beach, FL 74 Telephone:

77 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Tapered Splices For installation on copper conductor, solid center oil-stop, color coded barrel, rated up to 69 KV* PTC SERIES Color Coded Dimensions (inches) Catalog Conductor Size Die Set L B PTC 6 #6 Blue 4 9/ 7/ PTC 4 #4 Gray PTC # Brown PTC # Green 7 /6 / PTC /0 /0 Pink PTC /0 /0 Black 45 7/ / PTC /0 /0 Orange 50 / 9. / PTC 4/0 4/0 Purple 54 / PTC Yellow 6 9/6 7/ PTC White 66 5/8 / PTC Red 7 5/ 5/ PTC Blue 76 / 7/ PTC Brown 87 7/ / PTC Green / /6 076 PTC Black PTC Orange 4 9/ PTC White 5 4 / 7/ PTC Green 6 / 7/ PTC Brown 6 /6 5/ - L B Produced from seamless electrolytic copper tubing. Silver brazed oil-stop ensures no oil seepage. Indents should be filled with inert material. Lbs Per 00 Pcs * For high voltage applications, refer to the cable manufacturer. Southland Road, Ormond Beach, FL 74 Telephone:

78 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated One Hole Lugs For installation on copper conductor File E50999 File LR 5607 Produced from seamless electrolytic copper tubing. Marked with catalog number, conductor sizes and die references. L SERIES - LONG BARREL LENGTH Catalog Conductor Size Color Coded Die Set Bolt Size Dimensions (inches) L B P W C 5000 L 8-0 #0 5/ 9/ / 5/6 500 L 8-4 /4 #8 Red 4460 L 8-8 /8 7/6 5/ L 8-48 / 5/ 6077 L 6-0 # L 6-4 /4 #6 Blue L /6 /8 / L 6-8 /8 9/ L 4-0 # L 4-4 /4 #4 Gray L / L 4-8 /8 50 L -4 /4 50 L -56 5/6 # Brown 4457 L -8 /8 5/64 /6 / /4 /4 57/64 / /8 Lbs Per 00 Pcs..7. 9/.6 49 L -48 / 47/64 7/64 /4 7/ 505 L -4 / L -56 5/6 # Green L -8 /8 4/64 /8 508 L -48 / 57/64 7/ L /0-56 5/6 500 L /0-8 /0 Pink 4 /8 49/64 7/6 5/8 57/64 /6 /8 7/ 57/67 /4 / L /0-48 / 6/64 7/64 7/ 50 L /0-56 5/ L /0-8 /0 Black 45 /8 57/64 57/64 /6 506 L /0-48 / 7/64 7/64 7/ / 507 L /0-56 5/6 59/64 57/64 /8 500 L /0-8 /0 Orange 50 /8 508 L /0-48 / /8 9/ 9/64 7/64 7/ Southland Road, Ormond Beach, FL 74 Telephone:

79 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated One Hole Lugs For installation on copper conductor File E50999 File LR 5607 L SERIES - LONG BARREL LENGTH Catalog 509 L 4/0-56 Conductor Size Color Coded Die Set Bolt Dimensions (inches) Size L B P W C 5/6 /64 57/64 /8 5/64 9/6 7/64 7/ Lbs Per 00 Pcs. 500 L 4/0-8 4/0 Purple 54H /8. 50 L 4/0-48 / 50 L /6 /64 57/64 /8 50 L Yellow 6 /8 5/64 5/8 / L / 5/ L 00-8 / L White 66 / 5/64 7/ L /8 7/64 7/ 505 L 50-8 / L Red 7H / 55/64 9/ L /8 506 L /8 59/ L Blue 76 / /.4 4 5/ 508 L /8 / / 509 L / 500 Brown 87H 4 / /4 7/ L / L / 600 Green 94H 5 /8 /6 /4 / L /8 7/8 504 L / 575 L Black 06H 5/8 5 /6 7/8 5/6 9/ L /4 / 5044 L / 595 L White 5H 5/8 6 /4 /8 /6 5/ L / Southland Road, Ormond Beach, FL 74 Telephone:

80 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Two Hole Straight Lugs For installation on copper conductor File E50999 File LR 5607 L -4 to L /0-56 feature slotted rear bolt hole providing /4 and 7/8 bolt hole centers for added versatility. Other combinations available, please consult the factory. Allows inspection of the termination to assure complete cable insertion. Produced from seamless electrolytic copper tubing. L SERIES - LONG BARREL LENGTH Marked with catalog number, conductor sizes and die references. Conductor Color Coded Catalog Size Die Set 5000 L 6-4 #6 Blue 4 Bolt Dimensions (inches) Size L B P W C S /4 / 5/ 608 L /6 /6 / L 6 N / 5 /4 /8 9/ 500 L 4-4 /4 / / 5/6 5/ L 4-56 #4 Gray 9 5/6 /4 5/ L 4 N / 5 / L -4 /4 /8 /8 5/8 /6 /8 500 L -56 # Brown 5/6 /8 /4 9/6 9/ 8. /4 406 L N / 4 /4 5/6 /4 5/8 and 6087 L -4 /4 5/8 /8 /6 /8 5/8 7/8 500 L -56 # Green 7 5/6 /8 / 5/6 9.7 / 6088 L N / 4 7/8 5/ L /0-8 /8 /8 7/6 /8 5/8 / L /0-56 /0 Pink 4 5/6 / L /0 N / 4 7/ L /0-8 /8 5 /6 7/8 /0 Black L /0 N / 5 / / 7/ L /0-8 /8 5/6 /0 Orange 50 5 / L /0 N / 9/ L 4/0-8 /8 /6 4/0 Purple L 4/0 N / 5 /6 5/8 / L 50-8 /8 /8 50 Yellow 6 49 L 50 N / 5 /8 /4 7/ L 00-8 /8 /4 /4 00 White L 00 N / 7/ 5/8 5 / L 50-8 /8 5/6 50 Red L 50 N / 5/ L /8 /4 7/6 400 Blue 76 6 / L 400 N / / L 500 N 500 Brown 87 /6 /4 7/ L 600 N 600 Green 94 6 / 5/8 /8 / L 750 N 750 Black 06 / 7 7/8 / L 000 N 000 White 5 7 /4 5/6 /4 / L 500 N 500 Green 7 / / / L 000 N 000 Brown 8 /6 /6 / Lbs Per 00 Pcs. Trimmed to /4 max. to fit side by side on NEMA spades. N suffix on the catalog number indicates NEMA bolt spacing of / Southland Road, Ormond Beach, FL 74 Telephone:

81 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Two Hole Stacking Lugs For installation on copper conductor File E50999 File LR 5607 SL-N SERIES - LONG BARREL LENGTH Conductor Catalog Size Color Coded Die Set 484 SL /0 N /0 Black 45 Bolt Size Dimensions (inches) H L B P W C S / 5 / / Lbs Per 00 Pcs. 486 SL /0 N /0 Orange 50 5/8 5 /8 9/ SL 4/0 N 4/0 Purple 54 /6 5 /6 5/8 / SL 50 N 50 Yellow 6 /4 5 /8 /4.9 7/ 487 SL 00 N 00 White 66 / /4 488 SL 50 N 50 Red 7 / 7/8 5/6 5/8 / SL 400 N 400 Blue 76 5/6 6 /8 / / SL 500 N 500 Brown 87 /6 6 /6 /4 49 SL 600 N 600 Green 94 /6 6 / 5/8 /8 / / 6. 7/ SL 750 N 750 Black 06 5/6 7 7/8 / SL 000 N 000 White 5 5/8 7 /4 5/6 /4 / Trimmed to /4 max. to fit side by side on NEMA spades. N suffix on the catalog number indicates NEMA bolt spacing of /4. Southland Road, Ormond Beach, FL 74 Telephone:

82 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Four Hole NEMA Lugs For installation on copper conductor L 4 N SERIES Conductor Color Coded Bolt Dimensions (inches) Catalog Size Die Set Size L B P W C L N 750 Black 6 /4 / L N 000 White /4 /4 /4 / 5/ L N 500 Green 7 / 5/8 / L N 000 Brown 8 /6 /6 /6 Lbs Per 00 Pcs. Consult factory 60 0 N suffix on the catalog number indicates NEMA bolt spacing of /4. 78 Southland Road, Ormond Beach, FL 74 Telephone:

83 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated One Hole Peep Hole Lugs For installation on copper conductor, color coded barrel File E50999 File LR 5607 HL SERIES - STANDARD BARREL LENGTH Catalog 705 HL 8-0 Conductor Size Color Coded Die Set Bolt Size # HL 8-4 #8 Red / HL 8-48 / 5090 HL 6-0 # HL 6-4 /4 #6 Blue HL /6 Dimensions (inches) L B P W C Lbs Per 00 Pcs. 7/ / 9/ / 5/6 0.8 /4 /6 / HL 6-8 /8 9/ HL 4-0 # HL 4-4 /4 #4 Gray HL / HL 4-8 / HL -4 /4 509 HL -56 5/6 # Brown 509 HL -8 /8 6/64 9/ 57/64 /. /8 9/. 509 HL -48 / 5/ 7/64 /4 7/ 5094 HL -4 / HL -56 5/6 # Green HL -8 /8 5/8 9/64 7/8 57/64 /6 / HL -48 / 5/64 7/ HL /0-56 5/ HL /0-8 /0 Pink 4 /8 7/ 9/64 57/64 /4 / HL /0-48 / 5/64 7/64 7/ 509 HL /0-56 5/6 509 HL /0-8 /0 Black 45 /8 5/64 5/6 57/64 /6 509 HL /0-48 / 9/ 7/64 7/ 5094 HL / HL /0-8 /0 Orange 50 / HL /0-48 / 5097 HL 4/ HL 4/0-8 4/0 Purple 54 / HL 4/0-48 / 5/6 7/64 5/6 7/6 Peep hole allows inspection of the termination to assure complete cable insertion. Produced from seamless electrolytic copper tubing. Color coded barrels are marked with catalog number, conductor sizes, and die references. 57/64 /8 /8 /8 9/ / 7/64 7/ 57/64 /8 /6 9/6 7/64 7/ Southland Road, Ormond Beach, FL 74 Telephone:

84 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated One Hole Peep Hole Lugs For installation on copper conductor, color coded barrel File E50999 File LR 5607 Peep hole allows inspection of the termination to assure complete cable insertion. Produced from seamless electrolytic copper tubing. HL SERIES - STANDARD BARREL LENGTH Color coded barrels are marked with catalog number, conductor sizes, and die references. Catalog Conductor Size Color Coded Die Set Bolt Size Dimensions (inches) L B P W C Lbs Per 00 Pcs HL 50-8 /8 50 Yellow 6 / HL /6 7/64 7/ / HL White 66 /4 7/ HL /8 / / / 5055 HL / 5/6 7/64 50 Red HL /8 / HL / 400 Blue HL / HL / 500 Brown HL /8 9/ 7/ 7.6 9/ / / 9.6 / / 7/ /4 7/ HL / 600 Green 7/8 /8 /4 / HL /8 7/ HL / 6040 HL Black 5/8 4 /8 5/8 5/6 9/ HL / HL / 5/ HL White 5/8 4 5/6 5/6 /8 / HL HL Green /4 5 / /4 /6 / HL Brown 5 5/6 /4 /8 /6 /6 Consult factory Southland Road, Ormond Beach, FL 74 Telephone:

85 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Two Hole Peep Hole NEMA Lugs For installation on copper conductor File E50999 File LR 5607 HL-N SERIES - STANDARD BARREL LENGTH Catalog Conductor Size Color Coded Die Set 507 HL /0 N /0 Black 45 Bolt Size Dimensions (inches) L B P W C S 4 5/ 5/6 50 HL /0 N /0 Orange /8 9/ HL 4/0 N 4/0 Purple 54 4 / HL 50 N 50 Yellow 6 4 /4 /.4 / HL 00 N 00 White 66 4 /6 / HL 50 N 50 Red 7 4 5/6 /8 9/ HL 400 N 400 Blue 76 / 5 /8 /6 /8 5/8 / HL 500 N 500 Brown /6 7/ 54.0 /8 547 HL 600 N 600 Green 94 5 / / HL 750 N 750 Black 06 5 /4 5/8 9/ HL 000 N 000 White 5 6 5/ 7/8 / HL 500 N 500 Green 6 9/6 /6 Consult 604 HL 000 N 000 Brown 7 /4 /6 factory /6 Copper Tin-Plated Four Hole Peep Hole NEMA Lugs For installation on copper conductor HL 4 N SERIES * Catalog Conductor Size 604 HL N HL N 000 Bolt Size / Lbs Per 00 Pcs. Consult factory Std.Ctn. Peep hole allows inspection of the termination to assure complete cable insertion. Produced from seamless electrolytic copper tubing. Marked with catalog number, conductor sizes and die references. Lbs Per 00 Pcs * Not UL or CSA listed. Southland Road, Ormond Beach, FL 74 Telephone:

86 TRADE PRICE SCHEDULE Effective February, 007 Copper Heavy Duty Two Hole NEMA Lugs For installation on copper conductor Produced from seamless electrolytic copper tubing. Marked with catalog number, conductor sizes and die references. HDL-N SERIES - STANDARD BARREL LENGTH Catalog Conductor Size Color Coded Die Set Bolt Size Dimensions (inches) L B P W C S 6045 HDL N # Brown 6046 HDL N # Green 5 /4 / / HDL /0 N /0 Pink 7/ HDL /0 N /0 Black 5 / /4 5/ HDL /0 N /0 Orange 5 /6 /6 7/6 490 HDL 4/0 N 4/0 Purple 5 /4 /4 / HDL 50 N 50 Yellow / 5 5/8 5/ HDL 00 N 00 White 5 /6 /4 /8 604 HDL 50 N 50 Red 6 9/6 5/6 / 604 HDL 500 N 500 Brown 6 /8 5/8 /4 604 HDL 600 N 600 Green 7 / 5/8 5/ HDL 750 N 750 Black 7 /6 /8 / HDL 000 N 000 White 9 5/8 4 5/8 5/8 5/8 5/8 /4 Lbs Per 00 Pcs. Consult factory 0 Copper Heavy Duty Four Hole Lugs For installation on copper conductor HDL 4 N SERIES - STANDARD BARREL LENGTH Conductor Color Coded Bolt Dimensions (inches) Catalog Size Die Set Size L B P W C S HDL 4/0-4 N 4/0 Purple 6 /4 4 5/8 /4 / 500 HDL 50-4 N 50 Red N/A HDL N 500 Brown 7 /6 5/6 7/8 5/8 /4 / HDL N 600 Green N/A HDL N 750 Black 8 4 7/8 5/8 / HDL N 000 White Consult factory Lbs Per 00 Pcs. Consult factory Add suffix TN to the catalog number for tin-plating. Consult the factory for pricing. 8 Southland Road, Ormond Beach, FL 74 Telephone:

87 TRADE PRICE SCHEDULE Effective February, 007 Copper High Voltage Tapered Lugs Dual-rated, color coded barrel, rated up to 69 KV* L-V SERIES - ONE HOLE One Hole Catalog Conductor Size Two Hole Color Coded Die Set Lbs Per 00 Pcs. 650 L 4-8 V #4 Gray L -8 V # Brown L -8 V # Green L /0-8 V /0 Pink L /0-48 V /0 Black L /0-48 V /0 Orange L 4/0-48 V 4/0 Purple L V 50 Yellow L V 00 White L V 50 Red L-NV SERIES - TWO HOLE Catalog Conductor Size Color Coded Die Set Lbs Per 00 Pcs L /0 NV /0 Pink L /0 NV /0 Black L /0 NV /0 Orange L 4/0 NV 4/0 Purple L 50 NV 50 Yellow L 00 NV 00 White L 50 NV 50 Red L 400 NV 400 Blue L 500 NV 500 Brown L 600 NV 600 Green L 750 NV 750 Black L 000 NV 000 White * For high voltage applications, refer to the cable manufacturer. Southland Road, Ormond Beach, FL 74 Telephone:

88 TRADE PRICE SCHEDULE Effective February, 007 Lug Hugger Compression lug insulator Catalog Conductor Size AL CU 6896 G 06 #4 - /0 #4 - / K 87 /0-50 4/ B M E Southland Road, Ormond Beach, FL 74 Telephone:

89 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Tees For installation on copper conductor T SERIES Conductor Size Catalog Main Tap 8440 T # # /0 T 6 # /0 T 4 #4 844 /0 T /0 # /0 T # 8455 /0 T /0 / /0 T 6 # /0 T 4 #4 844 /0 T # / /0 T # /0 T /0 / /0 T /0 /0 844 /0 T /0 /0 / /0 T /0 / /0 T # /0 T # /0 T /0 4/0 / /0 T /0 / /0 T 4/0 4/ T # T # T /0 / T /0 / T 4/0 4/ T T T /0 / T /0 / T 4/0 4/ T Produced from seamless electrolytic copper tubing. Tin-plated to prevent corrosion resistance. Available in a variety of main and tap sizes. For other sizes, please consult the factory. 6 Catalog T /0 Conductor Size Main Tap / T /0 / T 4/0 4/ T T T T T /0 / T /0 / T 4/0 4/ T T T T T /0 / T 4/0 4/ T T T T T T T T Southland Road, Ormond Beach, FL 74 Telephone:

90 TRADE PRICE SCHEDULE Effective February, 007 Copper Tin-Plated Tapered Tees For installation on copper conductor, rated up to 69 KV* TT SERIES Produced from seamless electrolytic copper tubing. Tin-plated to prevent corrosion resistance. End taper is positive identification of high voltage heavy duty application. Available in a variety of main and tap sizes. For other sizes, please consult the factory. Catalog Conductor Size Main Tap 94 TT - # # 6045 TT /0-6 # TT /0-4 # TT /0- /0 # 6047 TT /0- # 947 TT /0-/0 / TT /0-6 # TT /0-4 # TT /0- # / TT /0- # 6044 TT /0-/0 /0 959 TT /0-/0 / TT /0-/0 /0 / TT /0-/0 / TT 4/0- # TT 4/0- # 965 TT 4/0-/0 4/0 / TT 4/0-/0 /0 969 TT 4/0-4/0 4/ TT 50- # TT 50- # TT 50-/0 / TT 50-/0 / TT 50-4/0 4/0 98 TT TT TT 50-/0 / TT 50-/0 / TT 50-4/0 4/0 989 TT Catalog TT 400-/0 Conductor Size Main Tap / TT 400-/0 / TT 400-4/0 4/ TT TT TT TT TT 500-/0 / TT 500-/0 / TT 500-4/0 4/ TT TT TT TT TT 600-/0 / TT 600-4/0 4/ TT TT TT TT TT TT TT TT * For high voltage applications, refer to the cable manufacturer. 86 Southland Road, Ormond Beach, FL 74 Telephone:

91 Split Bolts & Two Bolt Connectors 87

92 88

93 TRADE PRICE SCHEDULE Effective February, 007 Split Bolts Type E Catalog Type E-GP E SERIES - STANDARD COPPER TYPE (CU/CU) Conductor Range Equal Main & Tap (Min. - Max.) Body Length Body Width Nut Width Min. Tap with Max. Main Wire Slot File E50999 E- Series - For copper and copperweld wire. High strength connectors made of high copper content, corrosion resistant alloy for tapping, parrelling and dead-ending. Dimensions (inches) Body Width Nut Width Body Length Lbs Per 00 Pcs. 05 E 8 #0 Str./Sol. - #8 Str Str. 050 E 6 #8 Str./Sol. - #6 Str E 4 #8 Str./Sol. - #4 Str E #6 Str./Sol. - # Str./Sol E #6 Str./Sol. - # Str. 4 Str E /0 #4 Str./Sol. - /0 Str E /0 # Str./Sol. - /0 Str E /0 # Str./Sol. - /0 Str Str. 080 E 50 # Str./Sol Str E 50 /0 Str Str. /0 Str E Str Str. /0 Str E 750 4/0 Str Str /0 Str E Str Str E-GP SERIES - GENERAL PURPOSE COPPER TIN-PLATED TYPE WITH SPACER (CU/CU, AL/CU) Catalog Conductor Range Equal Main & Tap (Min. - Max.) Min. Tap with Max. Main Wire Slot E-GP Series - For aluminum, copper, steel wires and combinations. High strength, high copper content, corrosion resistant alloy body, nut, spacer and pressure bar are tin-plated for multi-material applications. Dimensions (inches) Body Width Nut Width Body Length Lbs Per 00 Pcs E 8 GP #0 Str./Sol. - #8 Str. 6 Str E 6 GP #8 Str./Sol. - #6 Str. 4 Str E 4 GP #8 Str./Sol. - #4 Str. 0 Str E GP #0 Sol. - # Str./Sol. 0 Sol E GP #6 Str./Sol. - # Str. 4 Str E /0 GP #4 Str./Sol. - /0 Str. 0 Str E /0 GP # Str./Sol. - /0 Str E /0 GP # Str./Sol. - /0 Str. 8 Str E 50 GP # Str./Sol Str E 50 GP /0 Str Str. /0 Str E 500 GP 00 Str Str E 750 GP 50 Str Str. /0 Str E 000 GP 500 Str Str Southland Road, Ormond Beach, FL 74 Telephone:

94 TRADE PRICE SCHEDULE Effective February, 007 Split Bolts Body Length Body Width File E50999 File LR 5607 For copper and aluminum wires and cominations. High strength connectors orient the conductor, no scratch brushing or oxide inhibitor required. Provides maximum pressure and assures a secure connection of main and tap conductors. 90 C rated. Type AE Nut Width AE SERIES - STANDARD ALUMINUM TYPE WITH WIRE SPACER (AL/AL, AL/CU, CU/CU) Catalog Equal Main & Tap (Min. - Max.) Conductor Range Min. Tap with Max. Main Wire Slot Dimensions (inches) Body Width Nut Width Body Length Lbs Per 00 Pcs AE 6 #6 Str./Sol. - #0 Str./Sol. #0 Sol. - #0 Sol AE 4 #4 Str./Sol. - #0 Str./Sol. #8 Sol. - #0 Sol AE # Str./Sol. - #8 Str. #6 Sol. - #8 Str AE /0 /0 Str. - #8 Str./Sol. # Str./Comp - #8 Sol Consult 6779 AE /0 /0 Str./Sol. - #8 Str. # Str./Comp - #8 Str factory AE 4/0 4/0 Str. - #6 Str. # Str./Comp - #6 Str AE Str. - #4 Str. /0 Str./Comp - #4 Str AE Str. - # Str./Comp 400 Comp - # Str./Comp Southland Road, Ormond Beach, FL 74 Telephone:

95 TRADE PRICE SCHEDULE Effective February, 007 Copper Two Bolt Connectors TBC Series TBC-S Series TBC SERIES - STANDARD COPPER TYPE (CU/CU) Conductor Range Dimensions (inches) Lbs Per Catalog Main Tap D H W 00 Pcs TBC #0-50 /8 / / TBC #0-500 / 9/ 0900 TBC / /8 / / 678 TBC / Consult factory TBC-S SERIES - GENERAL PURPOSE COPPER TIN-PLATED TYPE WITH SPACER (CU/CU, AL/CU) Conductor Range Dimensions (inches) Lbs Per Catalog Main Tap D H W 00 Pcs TBC 50 S * #6-50 /8 /4 / TBC 500 S * #4-500 / 5/ 9/ 6786 TBC 800 S * / /8 /4 / 6787 TBC 000 S * / /8 Consult factory File E50999 Compact, high strength, two bolt cast copper alloy connector. The two bolt construction allows maximum pressure to be applied directly to the conductor strands. Recommended for heavy duty connections. No special tools are required, install with an ordinary wrench or ratchet * UL listed for copper conductor only. Southland Road, Ormond Beach, FL 74 Telephone:

96 9

97 Grounding Connectors & Clamps C-Taps Ground Clamps for Water Pipes Ground Clamps for Armored Cable Ground Clamps for Conduit Ground Rod Couplings Clamps for Ground Rods Ground Girdle Pole Butt Grounding Plate Cast Bronze Ground Connectors Flexible Braid Jumpers 9

98 94

99 TRADE PRICE SCHEDULE Effective February, 007 Copper C-Type Compression Taps For installation on copper conductor CC SERIES Conductor Range Catalog Main Tap CC 48 #8 Sol. - #4 Str. #8 Sol. - #8 Str. 75 CC 46 #6 Sol. - #4 Str. #6 Sol. - #6 Str. 50 CC 44 #6 Sol. - #4 Str. #4 Sol. - #4 Str. 5 CC 4 #8 Sol. - #4 Str. # Sol. - # Str. 50 CC # Sol. - # Str. 7 CC 0 #8 Sol. - # Str. /0 Sol. - /0 Str. 9 CC 00 /0 Sol. - /0 Str. 8 CC 40 #6 Sol. - # Str. 0 CC 400 /0 Sol. - 4/0 Str. /0 Sol. - /0 Str. 60 CC 4040 /0 Sol. - 4/0 Str. Copperweld - Copper Conductor 8A 6A 4A A Use C-Tap accommodating #6 Str. copper Use C-Tap accommodating #4 Str. copper Use C-Tap accommodating # Str. copper Use C-Tap accommodating /0 - /0 copper L HMC s compression copper C-Tap connectors offer conductor range capability and are used for line tap-off and dead-ending and grounding. The connector can be held in the dies or jaws of an installation tool, then hooked directly over the line for time-saving installation. Length Installation Dies 5/8 TU, BG, 5/8 /4 C 7/8 E or O 00 /6 F or D When using # Str. in the Main, the Tap will accommodate #6 or #8 Str. or #8 Sol. For splicing or grounding the plated concentric neutral, HMC recommends tin-plated C-Taps. Add suffix TN to the catalog number and consult the factory for pricing. Southland Road, Ormond Beach, FL 74 Telephone:

100 TRADE PRICE SCHEDULE Effective February, 007 Ground Clamps for Water Pipes File E50999 HG- HG--BZ HG--S-BS HG--S-DB HG--Z HG--ZB* Catalog Water Pipe Size (inches) Max. Size Ground Wire Lbs Per 00 Pcs. Heavy Duty Bronze, Serrated Head, Plated Steel Screws 45 HG / HG / # Str. 47 HG / HG 4 / Standard Duty Bronze, Plated Steel Screws 400 HG O BZ / - #4 Str HG BZ / HG BZ / # Str. 404 HG 4 BZ / HG 6 BZ 4 / Standard Duty Bronze, Brass Screws 40 HG S BS / HG S BS /4 - # Str HG 4 S BS / Direct Burial Bronze, Silicon Bronze Screws 4 HG S DB / # Str. 4 HG S DB / Zinc Die-Cast, Plated Steel Screws 40 HG Z / # - #0 range 4 HG ZB* / *Not UL Listed. Zinc-plated, brass colored. 96 Southland Road, Ormond Beach, FL 74 Telephone:

101 TRADE PRICE SCHEDULE Effective February, 007 Ground Clamps for Armored Cable File E50999 HG--BS HG- HEG- HG-66-AW HG-0-DB Catalog Water Pipe Size (inches) Max. Size Ground Wire Lbs Per 00 Pcs. Heavy Duty Bronze, Serrated Head, Silicon Bronze Screws 45 HG BS / - 4/0 Str Heavy Duty Bronze, Serrated Head, Plated Steel Screws 440 HG / HG 4 / /0 Str. 44 HG 5 / HG 6 4 / Standard Duty Bronze, Plated Steel Screws 46 HEG / HEG 4 /4 - #6 Str HEG 5 / Standard Duty One-Piece Bronze, Plated Steel Screws 47 HG 0 AW / #4 Str. 48 HG 66 AW / Direct Burial One-Piece Bronze, Silicon Bronze Screws 45 HG 0 DB / - #4 Str Southland Road, Ormond Beach, FL 74 Telephone:

102 TRADE PRICE SCHEDULE Effective February, 007 Ground Clamps for Conduit File E50999 HG-5 HG-9 HEG-7 HG-5-EBS HG 75 HGHM 00 HGH 50 Catalog Water Pipe Size (inches) Max. Size Ground Wire Heavy Duty Bronze, Serrated Head, Plated Steel Screws 450 HG 5 / - Conduit Hub Size (inches) Lbs Per 00 Pcs HG 6 / /0 Str. / 45 HG 8 / HG 9 4 / HG 7 / HG 8 / /4 456 HG / HG 4 / /0 Str. 458 HG 9 / HG 0 / HG 4 / HG 5 4 / Standard Duty Bronze, Plated Steel Screws 470 HEG 5 / HEG 6 /4 - #6 Str. / HEG 8 / HEG 7 / HEG 8 /4 - /0 Str. / HEG / HEG 9 / HEG 0 /4 - /0 Str HEG 4 / Standard Duty Bronze, Silicon Bronze Screws * 46 HG 5 EBS / - #4 Str. / Standard Duty Bronze with 6 Flexible Copper Strap, Plated Steel Screws 490 HG 90 / - #4 Str HG 75 / - #6 Str / 49 HG 79 / - /0 Str HG 8 / - /0 Str Swing 60 Conduit Hub * 500 HGHM 50 - #0 Sol. - #4 Str. / HGHM 75 - #0 Sol. - /0 Str. / HGHM 00 - #0 Sol. - /0 Str..0 5 Standard Conduit Hub * 495 HGH 50 - / HGH 75 - #8 Sol. - #4 Str. / HGH *Not UL listed. 98 Southland Road, Ormond Beach, FL 74 Telephone:

103 TRADE PRICE SCHEDULE Effective February, 007 Ground Rod Couplings Bronze threaded couplings File E50999 Catalog Ground Rod Size (inches) Lbs Per 00 Pcs. 55 HGRCP 50 /.0 57 HGRCP 58 5/ HGRCP 4 / HGRCP Clamps for Ground Rods HGRC-HD Series Catalog HGRC Series Ground Rod Size (inches) Max. Size Ground Wire Lbs Per 00 Pcs. Heavy Duty Bronze, Direct Burial 56 HGRC 50 HD / HGRC 58 HD 5/8 /0 Str HGRC 4 HD /4 4.0 Standard Duty Bronze, Direct Burial 50 HGRC 8 /8 #4 Str HGRC 50 / HGRC 58 5/8 # Sol HGRC 4 /4.0 0 File E Southland Road, Ormond Beach, FL 74 Telephone:

104 TRADE PRICE SCHEDULE Effective February, 007 Ground Girdle System Solid copper girdle Dimensions (inches) Area Lbs Per Catalog Gauge Width Length (sq. in.) 00 Pcs GG GG 88 E 7 / 8 / GG 88 E V 7 / 8 / Pole Butt Grounding Plate Solid copper plate, accommodates up to # ground wire Catalog Width (inches) Lbs Per 00 Pcs / Southland Road, Ormond Beach, FL 74 Telephone:

105 TRADE PRICE SCHEDULE Effective February, 007 Cast Bronze Ground Connectors for Copper Bolts supplied for T equal /4. Specify other T if required. TYPE 709 T GROUND CONNECTOR CABLE TO FLAT Dimensions (inches) Catalog Conductor Range J A B T -4 #8 - #4 /4 / T -/0 #4 - /0 /8 / T -5 /0-50 / T / / 7/ T / / T /8 /4 / Dimensions (inches) Catalog Conductor Range J A B T -4 #8 - #4 /4 / T -/0 #4 - /0 / / T -5 / T / / T / T /8 /8 Dimensions (inches) Catalog Conductor Range J A B #8 - #4 /4 / /0 #4 - /0 /4 / /0-50 / / 7/8 / /8 Dimensions (inches) Catalog Conductor Range J A B #8 - #4 / /0 #4 - /0 /8 / / / / / / /8 /8 Lbs Per 00 Pcs. Consult factory TYPE 709 T GROUND CONNECTOR () CABLES TO FLAT TYPE 709- GROUND CONNECTOR CABLE TO FLAT /8 /4 /4 TYPE 709- GROUND CONNECTOR () CABLES TO FLAT TYPE 70- GROUND CONNECTOR () CABLE TO FLAT Lbs Per 00 Pcs. Consult factory Dimensions (inches) Catalog Conductor Range J A B C #8 - #4 / /0 #4 - /0 /8 /4 / / / / / /4 / /8 /4 /8 /4 Lbs Per 00 Pcs. Consult factory Lbs Per 00 Pcs. Consult factory Lbs Per 00 Pcs. Consult factory Southland Road, Ormond Beach, FL 74 Telephone:

106 TRADE PRICE SCHEDULE Effective February, Flexible Braid Jumpers TIn-plated flexible copper braid and high conductivity seamless copper ferrules C A W B T Catalog Flexible Braid # of Braids Total Circular Amp Rating Dimensions Prefix Side View in Ferrule Mils in Braid (Indoors) A B C T W FB - 77, /4 5/6 FB - 54, /4 5/6 FB -, /4 /6 Style FB FB , /6 /6 FB - 54,500 0 /4 / FB - 09, /4 5/8 FB - 46, /6 5/8 Style FB FB , /8 5/8 /4 5/8 FB -, /4 /6 FB - 46, /6 /6 FB - 694, / / Style FB FB , /8 5/8 FB 4-09, /4 / FB 4-67, / / FB 4-96, /8 5/8 FB 44- Style FB 4 4,5, /8 5/8 Catalog Catalog Catalog Catalog 0500 FB - NR 05 FB - NR 054 FB - NR 056 FB 4- NR 050 FB - N 8 R 05 FB - N 8 R 055 FB - N 8 R 057 FB 4- N 8 R 050 FB - N 4 R 054 FB - N 4 R 056 FB - N 4 R 058 FB 4- N 4 R 050 FB - NR 055 FB - NR 057 FB - NR 059 FB 4- NR 0504 FB - N 8 R 056 FB - N 8 R 058 FB - N 8 R 0540 FB 4- N 8 R 0505 FB - N 4 R 057 FB - N 4 R 059 FB - N 4 R 054 FB 4- N 4 R 0506 FB - NR 058 FB - NR 050 FB - NR 054 FB 4- NR 0507 FB - N 8 R 059 FB - N 8 R 05 FB - N 8 R 054 FB 4- N 8 R 0508 FB - N 4 R 050 FB - N 4 R 05 FB - N 4 R 0544 FB 4- N 4 R 0509 FB 4- NR 05 FB 4- NR 05 FB 4- NR 0545 FB 44- NR 050 FB 4- N 8 R 05 FB 4- N 8 R 054 FB 4- N 8 R 0546 FB 44- N 8 R 05 FB 4- N 4 R 05 FB 4- N 4 R 055 FB 4- N 4 R 0547 FB 44- N 4 R Standard jumpers have an overall length of 0 Southland Road, Ormond Beach, FL 74 Telephone:

107 Direct Burial Flood-Seal Splice Kits Radiating Rib Splice Kits Flood-Seal Mechanical Splice Kits Flood-Seal Compression Splice Kits Flood-Seal Twin Tap Kits 0

108 04

109 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Direct Burial Flood-Seal Mechanical Splice Kits Kit includes set screw connector, prefilled with oxide inhibitor and rubber insulating cover Catalog Style Description Conductor Range # Outlets Weight HSK 48 * 4/, /, 0/, 9.0 8/ with ground For UF Cable 4/, /, 0/, 804 UF 40 8/ with ground USK 40 Two Wire Kits Drop cord and tray cable conductor. #4, #, #0 with ground 000 USK /0 #4 - /0 8.0 File E USK USK 50- # USK USK 500 / USK UH # UH L.9 0 URS 5 (Compression) 068 SL - K Three Wire Kits 0 USK 4/0 SL 0 FSS UH SL 0 MTB 50- Four Wire Kits # #4 - #4 CU # - #4 AL #6-50 (cable range when using SL tap is /0-4/0) #4 Sol. - #6 SL tap 6. wire capability accommodates SL tap.0 # - # #6-50 (cable range when using SL tap is /0-4/0) #4 Sol. - #6 SL tap 4 wire capability accommodates SL tap # MTB * HSK 48 kit includes heat-shrink tubing. Southland Road, Ormond Beach, FL 74 Telephone:

110 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Compression Splice Kits Kit includes connector, prefilled with oxide inhibitor, and rubber insulating cover. FLOOD-SEAL RRK SERIES Catalog Conductor Size Lbs Per (From-To) AL only 00 Pcs. 086 RRK 6 #6 087 RRK 4 # RRK # 605 RRK 4 # - # RRK # RRK 0 / RRK 0 /0 - # RRK 0 / RRK 0 /0 - # RRK 0 /0 - # 6055 RRK 00 /0 -/ RRK 0 / RRK 00 /0 - / RRK 00 /0 - / RRK 40 4/ RRK 400 4/0 - / RRK 400 4/0 - / RRK 400 4/0 - / RRK / RRK RRK RRK RRK RRK /0 00 RRK Underground splice, the Radiating Rib connector allows use of our UT or UT M hand tool for wire sizes up to 4/0. Please refer to page 49 for details. Easy, labor saving - only 0 wide trench required for installation - especially convenient for making repairs. Heat dissipating radiating rib centers watertight insulating cover, seals perfectly every time. Proven rubber Flood-Seal insulating cover fits snugly for maximum heat dissipation. Fully tested - meets requirements of ANSI C Southland Road, Ormond Beach, FL 74 Telephone:

111 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Direct Burial Flood-Seal Compression Splice Kits Kit includes dual-rated connector, prefilled with oxide inhibitor, and rubber insulating cover FSK SERIES Catalog Conductor Size (From-To) 6054 FSK 4 # FSK # FSK # FSK /0 / FSK /0 R /0 - # FSK /0 / FSK /0 R /0 /0 - / FSK /0 / FSK 4/0 4/ FSK 4/0 R /0 4/0 - / FSK FSK FSK FSK 50 R 4/0 50-4/ FSK FSK FSK 500 R 4/ / FSK 500 R FSK FSK FSK 750 R FSK FSK 000 R FSK 000 R Lbs Per 00 Pcs Rockets can be pre-cut. Add suffix CAB to the catalog number and consult the factory for pricing. Southland Road, Ormond Beach, FL 74 Telephone:

112 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Direct Burial Flood-Seal In-Line Compression Splice Kits Kit includes connector, prefilled with oxide inhibitor, and rubber insulating cover Each splice is approved for AL-CU connections File E50999 To insure equal cable insertion, connectors have center cable stop. ULSK SERIES Catalog Conductor Size ULSK 8 # ULSK 6 #6 04 ULSK 4 #4 047 ULSK # 0490 ULSK # 045 ULSK /0 /0 Lbs Per 00 Pcs ULSK /0 / ULSK /0 / ULSK 4/0 4/ ULSK ULSK ULSK ULSK ULSK ULSK ULSK ULSK ULSK Rockets can be pre-cut. Add suffix CAB to the catalog number and consult the factory for pricing. 08 Southland Road, Ormond Beach, FL 74 Telephone:

113 TRADE PRICE SCHEDULE Effective February, 007 Copper Direct Burial Flood-Seal In-Line Compression Splice Kits Kit includes connector and rubber insulating cover ULCK SERIES Catalog Conductor Size ULCK 8 #8 000 ULCK 6 # ULCK 4 #4 00 ULCK # 00 ULCK # 004 ULCK /0 /0 005 ULCK /0 /0 006 ULCK /0 /0 007 ULCK 4/0 4/0 008 ULCK ULCK ULCK ULCK ULCK ULCK ULCK ULCK ULCK Lbs Per 00 Pcs. Consult factory 0 5 Each splice is approved for CU connections File E50999 To insure equal cable insertion, connectors have center cable stop Rockets can be pre-cut. Add suffix CAB to the catalog number and consult the factory for pricing. Southland Road, Ormond Beach, FL 74 Telephone:

114 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Direct Burial Flood-Seal Compression Twin Tap Kits Kit includes H-type dual-rated compression connector, prefilled with oxide inhibitor, and rubber insulating cover H Series GH Series CONTINUING MAIN KITS - ONE OR TWO TAPS Catalog Num.ber Groove A - Stranded Cable Groove B - Stranded Cable Concentric Compact Compressed Concentric Compact Compressed 46 HO # - #6 # - #6 # - #6 # - #6 # - #6 # - #6 0 HO 5 /0 - # /0 - # /0 - # # - #6 /0 - #6 # - #6 0 HO 7 /0 - #4 /0 - #4 /0 - #4 /0 - #4 /0 - #4 /0 - #4 04 HD # - #6 # - #6 # - #6 05 HD /0 50-4/ /0 /0 - # /0 - # /0 - # 4 HD /0 50-4/ /0 07 HN 8 /0 - #6 /0 - #6 /0 - #6 08 HN /0 - /0 4/0 - /0 4/0 - /0 09 HN GHO 5 # - #6 # - #6 # - #6 # - #6 # - #6 # - # GHO 5 /0 - # /0 - # /0 - # # - #6 /0 - #6 # - # GHO 5 /0 - #4 /0 - #4 /0 - #4 /0 - #4 /0 - #4 /0 - # GHD 54 # - #6 # - #6 # - #6 606 GHD /0 50-4/ /0 /0 - # /0 - # /0 - # 606 GHD /0 50-4/ /0 606 GHN 57 /0 - #6 /0 - #6 /0 - # GHN /0 - /0 4/0 - /0 4/0 - / GHN Die O D N O D N Lbs Per 00 Pcs. Consult factory TERMINATED MAIN KIT - TWO TAPS Groove A - Stranded Cable Groove B - Stranded Cable Catalog Concentric Compact Compressed Concentric Compact Compressed 46 HO # - #6 # - #6 # - #6 # - #6 # - #6 # - #6 0 HO /0 - # /0 - # /0 - # # - #6 /0 - #6 # - #6 0 HO 7 /0 - #4 /0 - #4 /0 - #4 /0 - #4 /0 - #4 /0 - #4 HD 6 # - #6 # - #6 # - #6 HD /0 50-4/ /0 /0 - # /0 - # /0 - # 4 HD /0 50-4/ /0 5 HN 4 /0 - #6 /0 - #6 /0 - #6 6 HN /0 - /0 4/0 - /0 4/0 - /0 09 HN Die O D N Lbs Per 00 Pcs. Consult factory 0 Southland Road, Ormond Beach, FL 74 Telephone:

115 Heat-Shrink Splice Kits

116

117 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Compression Heat-Shrink Splice Kits Kit includes connector, prefilled with oxide inhibitor, and heavy-wall heat-shrink tubing RRK-HS SERIES Catalog Conductor Size Lbs Per (From-To) AL only 00 Pcs. 040 RRK 6 HS #6 040 RRK 4 HS # RRK HS # 0400 RRK HS # RRK 0 HS / RRK 0 HS /0 - # RRK 0 HS / RRK 0 HS /0 - # 0408 RRK 00 HS /0 - / RRK 0 HS / RRK 40 HS 4/0 04 RRK 400 HS 4/0 - / RRK 400 HS 4/0 - /0 04 RRK HS 4/ RRK 50 HS RRK 00 HS RRK 50 HS RRK 5000 HS RRK 5040 HS 50-4/ RRK 500 HS Underground splice, the Radiating Rib connector allows use of our UT or UT M hand tool for wire sizes up to 4/0. Please refer to page 47 for details. Easy, labor saving - only 0 wide trench required for installation - especially convenient for making repairs. Heat dissipating radiating rib centers perfectly every time. Proven heavy-wall heat-shrink tubing. Fully tested - meets requirements of ANSI C Southland Road, Ormond Beach, FL 74 Telephone:

118 TRADE PRICE SCHEDULE Effective February, 007 Aluminum In-Line Compression Heat-Shrink Splice Kits Kit includes connector, prefilled with oxide inhibitor, and heavy-wall heat-shrink tubing File E50999 Each splice is approved for AL-CU connections To insure equal cable insertion, connectors have center cable stop. ULSK-HS SERIES Catalog Conductor Size ULSK 6 HS # ULSK 4 HS # ULSK HS # 6057 ULSK HS # 6057 ULSK /0 HS /0 Lbs Per 00 Pcs ULSK /0 HS / ULSK /0 HS / ULSK 4/0 HS 4/ ULSK 50 HS ULSK 00 HS ULSK 50 HS ULSK 400 HS ULSK 500 HS ULSK 600 HS ULSK 750 HS ULSK 800 HS ULSK 000 HS Southland Road, Ormond Beach, FL 74 Telephone:

119 TRADE PRICE SCHEDULE Effective February, 007 Copper In-Line Compression Heat-Shrink Splice Kits Kit includes connector and heavy-wall heat-shrink tubing File E50999 ULCK-HS SERIES Catalog Conductor Size ULCK 8 HS # ULCK 6 HS # ULCK 4 HS # ULCK HS # 6059 ULCK HS # ULCK /0 HS / ULCK /0 HS / ULCK /0 HS / ULCK 4/0 HS 4/ ULCK 50 HS ULCK 00 HS ULCK 50 HS ULCK 400 HS ULCK 500 HS ULCK 600 HS ULCK 750 HS ULCK 000 HS 000 Lbs Per 00 Pcs. Consult factory 0 5 Each splice is approved for CU connections To insure equal cable insertion, connectors have center cable stop Southland Road, Ormond Beach, FL 74 Telephone:

120 6

121 Street & Highway Lighting Connectors & Kits 7

122 8

123 TRADE PRICE SCHEDULE Effective February, 007 Insulated Street & Highway Lighting Mechanical Connectors For above-ground applications RB SERIES - RUBBER INSULATED Catalog Conductor Range 6065 RB 0-8 SL Main /0 max. 450 RB 0-8 SS Tap # - # RB 640 SL Main /0 - #4 Tap #4 - #6 Catalog Conductor Range Lbs Per 00 Pcs SLV SERIES - CLEAR PVC ENCAPSULATED RB Series SLV Series BY 0 Catalog Conductor Range 6067 SLV 40-4 Main () 4/0 - #6 Tap () #4 - # SLV 4- # - # 0.0 BY SERIES - Y-TYPE TIN-PLATED, PVC INSULATED 0 Lbs Per 00 Pcs. Lbs Per 00 Pcs. 980 BY 0 * #4 - / * Mechanical connector installed with /8 hex wrench. Southland Road, Ormond Beach, FL 74 Telephone:

124 TRADE PRICE SCHEDULE Effective February, 007 Flood-Seal Street & Highway Lighting Compression Disconnect Kits Kit includes connector, fuse clips, dowel, silicone lubricant and rubber insulating cover Break-away design - kit separates under tension so wires won t break. Safe - fuse or connecting link always stays in load side when separated. In-Line Kit Twin In-Line Kit IN-LINE KITS Catalog Fused/ Non Fused Conductor Range Main Tap 0907 SLK 6 #4 - #6 #4 - # SLK Fused #4 - # #4 - # 0909 SLK 6- #4 - # SDK 6 #4 - #6 090 SDK Non Fused * #4 - # #4 - # 090 SDK 6- #4 - #6 Lbs Per 00 Pcs. Consult factory 0 TWIN IN-LINE KITS Fused/ Conductor Range Catalog Non Fused Main Tap 090 SLT 6 #4 - #6 #4 - # SLT Fused #4 - # #4 - # 0905 SLT 6- #4 - # SDT 6 #4 - # SDT Non Fused * #4 - # #4 - # 0908 SDT 6- #4 - #6 Lbs Per 00 Pcs. Consult factory volt 0 amp fuse not included. Fused kits accept standard cartridge fuse with / diameter, -/ length non-glass type. * Connecting link also included. 0 Southland Road, Ormond Beach, FL 74 Telephone:

125 TRADE PRICE SCHEDULE Effective February, 007 Flood-Seal Street & Highway Lighting Compression Disconnect Kits Kit includes lugs, fuse clips, set of reducers, dowel, hardware, silicone lubricant and rubber insulating cover Re-enterable for sectionalizing. Y-TYPE KITS - ALUMINUM RUN COPPER TAP Catalog Fused/ Non Fused Conductor Size (AL Stranded) Installing Dies FYA FYA FYA Fused 5, BG, 4, 5/ FYA /0 / FYA /0 /0 58, 97, 45, 5/ DYA DYA DYA Non Fused * 5, BG, 4, 5/8 594 DYA /0 / DYA /0 /0 58, 97, 45, 5/8- Y-TYPE KITS - COPPER RUN COPPER TAP Catalog FYC 8 Fused/ Non Fused Watertight and submersible. Break-away design - kit separates under tension so wires won t break. Safe - fuse or connecting link always stays in load side when separated. Run or feeder lugs have same ampacity rating as the cable, up to /0. Fits insulated wires up to.78 diameter. Conductor Size (AL Stranded) Installing Dies Lbs per 00 Pcs. Consult factory 8 /4, 6, TC, FYC 6 6 J, 7, TE, FYC 4 4 5/6, 8, TP, FYC Fused /8, 0, TL-TN, FYC /8,, TB, FYC /0 /0 /,, TQ, FYC /0 /0 9/6,, TS, DYC 8 8 /4, 6, TC, DYC 6 6 J, 7, TE, DYC 4 4 5/6, 8, TP, DYC Non Fused * /8, 0, TL-TN, DYC /8,, TB, DYC /0 /0 /,, TQ, DYC /0 /0 9/6,, TS, Lbs per 00 Pcs volt 0 amp fuse not included. Fused kits accept standard cartridge fuse with / diameter, -/ length non-glass type. * Connecting link also included. Southland Road, Ormond Beach, FL 74 Telephone:

126 TRADE PRICE SCHEDULE Effective February, 007 Direct Burial Flood-Seal Street & Highway Lighting Compression Disconnect Kits Kit includes connector, fuse clips, dowel, silicone lubricant and rubber insulating cover YY-TYPE - ALUMINUM Catalog Fused/ Non Fused Conductor Size Main 6069 YFA 8 # YFA 6 #6 606 YFA 4 #4 Fused 606 YFA # 6066 YFA /0 / YFA /0 /0 686 YDA 8 #8 687 YDA 6 #6 688 YDA 4 #4 Non Fused * 689 YDA # 680 YDA /0 /0 68 YDA /0 /0 Tap #4 - #6 Lbs Per 00 Pcs. Consult factory 0 YY-TYPE - COPPER Fused/ Conductor Size Catalog Non Fused Main Tap 68 YFC 8 #8 68 YFC 6 #6 684 YFC 4 #4 Fused 685 YFC # 686 YFC /0 /0 687 YFC /0 /0 688 YDC 8 #8 #4 - #6 689 YDC 6 # YDC 4 #4 Non Fused * 684 YDC # 684 YDC /0 /0 698 YDC /0 /0 Lbs Per 00 Pcs. Consult factory volt 0 amp fuse not included. Fused kits accept standard cartridge fuse with / diameter, -/ length non-glass type. * Connecting link also included. Southland Road, Ormond Beach, FL 74 Telephone:

127 TRADE PRICE SCHEDULE Effective February, 007 Direct Burial Flood-Seal Street & Highway Lighting Mechanical Disconnect Kits Kit includes connector, fuse clips, dowel, silicone lubricant and rubber insulating cover IN-LINE KITS In-Line Kit Catalog 0504 SLK M 0700 SLT M 00 SDK M 070 SDT M Fused/ Non Fused IN-LINE VARIABLE RANGE KITS Y-TYPE KITS Inline - Single Inline - Twin Conductor Range (Al/Cu) Stranded Fused #, #0, #8, #6, #4 In-Line Kit, Variable Range Solid #, #0, #8, #6, #4 Lbs Per 00 Pcs. 7.0 Non Fused.0 Fused/ Conductor Range (Al/Cu) Lbs Per Catalog Non Fused Main Tap 00 Pcs SLK M # - #4 8. # - # SLK 0 M 9.0 /0 - # 606 SLK 00 M /0 - #. Fused SLK -60 M # - #4.4 # - # SLK 0-60 M.7 0 /0 - # SLK M /0 - # SDK M # - #4 # - # SDK 0 M Non Fused * 5.0 /0 - # SDK 00 M /0 - # 6. Fused/ Conductor Range (Al/Cu) Lbs Per Catalog Non Fused Main Tap 00 Pcs. 08 FYU M Fused 5.4 #4 - # # - # DYU M Non Fused * 6.8 Y-TYPE MECHANICAL RUN COMPRESSION TAP KITS Fused/ Conductor Range Catalog Non Fused Main Tap 0909 FYU 6 #4 - #6 Fused FYU #4 - # #4 - # 0904 DYU 6 #4 - #6 Non Fused * 0904 DYU #4 - # 0 Lbs Per 00 Pcs Y-Type Kit Mechanical Run/ Compression Tap Kit volt 0 amp fuse not included. Fused kits accept standard cartridge fuse with / diameter, -/ length non-glass type. 60 amp fuse max. 60 amp fuses are /4 long. Indicates twin housing. * Connecting link also included. Southland Road, Ormond Beach, FL 74 Telephone:

128 TRADE PRICE SCHEDULE Effective February, 007 Flood-Seal Street & Highway Lighting Mechanical Disconnect Kits Kit includes connector, fuse clips, dowel, silicone lubricant and rubber insulating cover YY-TYPE DISCONNECT KITS Catalog Fused/ Non Fused Conductor Range 6064 YFU Fused #4 - #4 CU 6065 YDU Non Fused * #4 - # AL Lbs Per 00 Pcs. Consult factory volt 0 amp fuse not included. Fused kits accept standard cartridge fuse with / diameter, -/ length non-glass type. * Connecting link also included. 4 Southland Road, Ormond Beach, FL 74 Telephone:

129 TRADE PRICE SCHEDULE Effective February, 007 Direct Burial Flood-Seal Insulating Covers File E50999 FSS SERIES SUBMERSIBLE SPLICE COVERS Catalog Conductor Range Length (inches) 49 FSS 0 /4.0 #4 - / FSS 0 L. 494 FSS /6. # FSS 50 L 7 / FSS /6 7.0 # FSS 500 L 7 5/ FSS 000 S Splice Cover Three Wire Cover Four Wire Cover 49 FSS # FSS Lbs Per 00 Pcs FSS 000 L 8 /8 0.4 FSS SERIES TWIN TAP THREE & FOUR WIRE COVERS * Conductor Range Catalog A B C 0700 FSS 00-4 #4 - /0 #4 - /0 N/A 0 Length (inches).0 5 /8 070 FSS # FSS L # / FSS 4040 #4-50 # / FSS 4040 L #4-500 #8-50 #4 - /0 7 5/ FSS 500 #4 - /0 #4 - /0 / FSS 505 # #4-500 # / FSS #4-500 #4-400 N/A 5 /4 7. Lbs Per 00 Pcs. Indefinitely maintains watertight integrity and full insulating value in all direct buried, underground network, residential and overhead service splice joints. Taping is eliminated, labor and material cost of splice preparation is significantly reduced * Not UL listed. Southland Road, Ormond Beach, FL 74 Telephone:

130 6

131 Multi-Seal Multi-Port Connectors 7

132 8

133 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal Multi-Port Connector Dual-rated, rubber insulated RAB /0 SERIES L RAB /0- RAB /0- Catalog Conductor Range # Outlets Dimensions (inches) Lbs Per Length Height 00 Pcs. 504 RAB /0- / RAB /0-5/ RAB /0-4 4 / RAB / / RAB / / RAB / RAB / / RAB /0-9 #4 - /0 9 7 / /.0 50 RAB / / RAB /0-5/ RAB /0-4 / 6069 RAB /0-4 / RAB /0-5 4 / RAB /0-6 9/ RAB / / 8.0 L Rugged construction - fabricated from 606-T6 aluminum with molded rubber insulation. Fully insulated and water tight - suitable for direct burial, handhole and streetlight applications. Easy to follow instructions molded into top of connector. Ball bottom screw design breaks up interstrand oxides. Rubber cap designed to prevent accidental removal Add suffix C to the catalog number for oxide inhibitor, and add cents per cable port to the price. Southland Road, Ormond Beach, FL 74 Telephone:

134 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal Multi-Port Connector Dual-rated, rubber insulated EZ-View window to provide visual indication of proper cable insertion. Inward seal rockets to ease cable insertion. Tethered screw plugs to prevent plug loss during installation. Ball bottom screw design RAB Resealable rockets. Molded-in installation instructions. RAB 50 SERIES - EZ VIEW CONDUCTOR PORTS Catalog 606 RAB Conductor Range # Outlets Dimensions (inches) Lbs Per Length Height 00 Pcs. 7/ RAB 5/ RAB / RAB 5 # Sol / RAB / RAB / RAB 0 0 5/ Add suffix C to the catalog number for oxide inhibitor, and add cents per cable port to the price. 0 Southland Road, Ormond Beach, FL 74 Telephone:

135 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal Multi-Port Connector Dual-rated, rubber insulated RXL 4 RAB 45 RXL RXL 600- RXL 50 SERIES - WIDER PORT SPACING Catalog 6074 RXL RAB 500 SERIES Conductor Range # Outlets Dimensions (inches) Lbs Per Length Height 00 Pcs. 44 RXL /6 4.6 # Sol RXL / RXL 600 SERIES - WIDER PORT SPACING / RXL 4 5/ RXL / RXL 8 8 7/ Catalog Conductor Range # Outlets Dimensions (inches) Lbs Per Length Height 00 Pcs. 607 RAB 5 5 / RAB RAB 55 # Sol /6 5/ RAB / RAB / 00.8 Catalog Conductor Range # Outlets Dimensions (inches) Lbs Per Length Height 00 Pcs RXL / RXL / RXL / RXL /6 6. # / 607 RXL / RXL RXL RXL /6 6. Rugged construction - fabricated from 606-T6 aluminum with molded rubber insulation. Fully insulated and water tight - suitable for direct burial, handhole and streetlight applications. Easy to follow instructions molded into top of connector. Ball bottom screw design breaks up interstrand oxides. Rubber cap designed to prevent accidental removal Add suffix C to the catalog number for oxide inhibitor, and add cents per cable port to the price. Southland Road, Ormond Beach, FL 74 Telephone:

136 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal Multi-Port Connector Dual-rated, rubber insulated, for overhead or underground applications RXM RXM 4 RXM RXM 000 SERIES Catalog Conductor Range # Outlets Dimensions (inches) Lbs Per Length Height 00 Pcs RXM /6 45 RXM /4 056 RXM /8 058 RXM / 7077 RXM / RXM /4 # Sol RXM 4 7 / RXM 4 7 / RXM 6 0 7/ RXM / 0777 RXM / 0778 RXM 66 /4 /6 Consult factory Rugged construction - fabricated from 606-T6 aluminum with molded rubber insulation. Fully insulated and water tight - suitable for overhead or underground applications. Easy to follow instructions molded into top of connector. Ball bottom screw design breaks up interstrand oxides. Rubber cap designed to prevent accidental removal. Add suffix C to the catalog number for oxide inhibitor, and add cents per cable port to the price. Southland Road, Ormond Beach, FL 74 Telephone:

137 Flood-Seal & Sweetheart Connectors & Covers

138 4

139 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal 75 Series Service Entrance Connectors For Two Hole Nema Lugs Up To 000 Kcmil Dual-rated, rubber insulated, complete with lug mounting hardware One Way Configuration Two Way Configuration FS 75 DPK FS 75 SERIES - ONE WAY CONFIGURATION Catalog # Outlets 080 FS FS FS FS FS FS FS Lbs Per 00 Pcs. FS 75 SERIES - TWO WAY CONFIGURATION Catalog # Outlets 00 FS FS FS FS FS FS FS FS Lbs Per 00 Pcs. Consult factory Flood-Seal 75 Series Adapter Kit For Two Conductors Per Outlet Rubber insulated aluminum kit includes twin tower rocket, adapter ring and new hardware (connector not included) Catalog Lbs Per 00 Pcs FS 75 DPK Add suffix AWR to the catalog number for complete assembly with FS 75 insulating rockets. Consult the factory for pricing, or order rockets separately. Refer to page 7 for FS 75 Series rockets. Southland Road, Ormond Beach, FL 74 Telephone:

140 TRADE PRICE SCHEDULE Effective February, 007 Copper Flood-Seal 75 Series Service Entrance Connectors For Two Hole Nema Lugs Up To 000 Kcmil Dual-rated, rubber insulated, complete with lug mounting hardware One Way Configuration Two Way Configuration FS 75 SERIES - ONE WAY CONFIGURATION Catalog # Outlets 060 FS 75- CU 06 FS 75- CU 06 FS 75-4 CU 4 06 FS 75-5 CU FS 75-6 CU FS 75-7 CU FS 75-8 CU 8 Lbs Per 00 Pcs. Consult factory FS 75 SERIES - TWO WAY CONFIGURATION Catalog # Outlets 070 FS -75 CU FS -75 CU FS CU 8 07 FS CU FS CU 075 FS CU FS CU FS -75 CU 4 Lbs Per 00 Pcs. Consult factory Add suffix AWR to the catalog number for complete assembly with FS 75 insulating rockets. Consult the factory for pricing, or order rockets separately. Refer to page 7 for FS 75 Series rockets. Use FS 75 DPK adapter kit for two conductors per outlet. See page Southland Road, Ormond Beach, FL 74 Telephone:

141 TRADE PRICE SCHEDULE Effective February, 007 Flood-Seal Insulating Rockets Single Tower Rocket CS & FS SERIES Catalog 480 CS 77 For Bus Series CS TWIN TOWER SERIES Twin Tower Rocket 0 CSN CS CSN CS FS 75 S FS FS 75 L 6.8 Catalog 44 CST 095 For Bus Series 6086 CST CSN Lbs Per 00 Pcs Lbs Per 00 Pcs Flood-Seal 75 Series Accessories For use with 75 Series connectors ALUMINUM TWO HOLE LUGS AL-NTN Series See page 44 COPPER TWO HOLE LUGS L Series See page Southland Road, Ormond Beach, FL 74 Telephone:

142 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal Mechanical Connectors Dual-rated, PVC insulated, prefilled with oxide inhibitor SHC 50 Series SHC 50- Series SHC 500 Series SHC 50 SERIES Lbs Per Catalog Conductor Range # Outlets 00 Pcs. 479 SHC Feeder # SHC 4 (cable range when using SL tap is /0-50) 48 SHC SHC 6 Tap #4 - / SHC 8 SL #4 Sol. - # SHC 50- SERIES Lbs Per Catalog Conductor Range # Outlets 00 Pcs. 04 SHC SHC Feeder #6-50 (cable range when using SHC SL tap is /0-50) SHC Tap #4 - / SHC SL #4 Sol. - # SHC 5.00 SHC 500 SERIES Catalog Conductor Range # Outlets SHC 500- Lbs Per 00 Pcs SHC SHC # SHC SHC SHC Connector supplied with insulating rockets. 8 Southland Road, Ormond Beach, FL 74 Telephone:

143 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal Mechanical Connectors Dual-rated, PVC insulated, prefilled with oxide inhibitor SHC Double 4/0 Series SHC DOUBLE 4/0 SERIES SHC 500 SERIES WITH 4/0 SERVICE SHC 500 Series with 400 Service Catalog Style Conductor Range SHC 40 #4-4/0 Lbs Per 00 Pcs SHC Catalog Style Conductor Range Lbs Per 00 Pcs SHC SL Feeder # SHC SL Tap #4-4/ SHC SL SL #4 - # Connector supplied with insulating rockets. Southland Road, Ormond Beach, FL 74 Telephone:

144 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal Twin Screw Mechanical Connectors Dual-rated, PVC insulated, prefilled with oxide inhibitor UH 50 Series One Way Configuration UH 50 Series Two Way Configuration UH 500 Series UH 750 Series UH 50 SERIES - ONE WAY CONFIGURATION Catalog Conductor Range # Outlets 6068 UH R Lbs Per 00 Pcs UH R UH 4 R # UH 5 R UH 6 R UH 8 R UH 50 SERIES - TWO WAY CONFIGURATION Catalog Conductor Range # Outlets UH R UH 500 SERIES UH 750 SERIES Lbs Per 00 Pcs UH R UH 44 R # UH 55 R UH 66 R UH 88 R Catalog Conductor Range # Outlets UH 500- R Lbs Per 00 Pcs UH 500- R UH R 4.5 # UH R UH R UH R Lbs Per Catalog Conductor Range # Outlets 00 Pcs UH SLR / UH SLR SL #4 - # 6 8. Connector supplied with insulating rockets. 40 Southland Road, Ormond Beach, FL 74 Telephone:

145 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal Mechanical Connectors Dual-rated, PVC insulated, prefilled with oxide inhibitor UH 750 Series UH 750 SERIES WITH 4/0 SERVICES Catalog Conductor Range UH SLR Feeder / UH SLR Tap # - 4/ UH SLR SL #4 - #4 UH 750 SERIES WITH 50 SERVICES Catalog Conductor Range UH SLR Feeder / UH SLR Tap # UH SLR SL #4 - #4 Lbs Per 00 Pcs. Consult factory Lbs Per 00 Pcs. Consult factory Connector supplied with insulating rockets. Southland Road, Ormond Beach, FL 74 Telephone:

146 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Flood-Seal Mechanical Connectors Dual-rated, PVC insulated, prefilled with oxide inhibitor UH 000 Series One Way Configuration UH 000 Series Two Way Configuration UH 000 Series with 50 Services UH 000 SERIES - TWIN SCREW ONE WAY CONFIGURATION Catalog Conductor Range # Outlets 6070 UH 000- R 6070 UH R 4 # UH R UH R 8 Lbs Per 00 Pcs. Consult factory UH 000 SERIES - TWIN SCREW TWO WAY CONFIGURATION Catalog Conductor Range # Outlets UH 000- R UH 000- R UH R 8 # UH R UH R UH R 6 Lbs Per 00 Pcs. Consult factory UH 000 SERIES WITH 50 SERVICES Catalog Conductor Range # Outlets 6070 UH 000- R Feeder # UH 000- R Tap # UH R SL #4 - #6 8 Lbs Per 00 Pcs. Consult factory Connector supplied with insulating rockets. 4 Southland Road, Ormond Beach, FL 74 Telephone:

147 Barracuda Insulation Piercing Connectors 4

148 44

149 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Underground Insulation Piercing Splices & Connectors Dual-rated, rubber insulated, prefilled with oxide inhibitor RIPS SERIES RIPS 0 RIPS 50 RIPC 50- RIPC 50- RIPC 50- Catalog Conductor Range Torque in. lb. Lbs Per 00 Pcs. 057 RIPS 0 #0 - /0 5 Consult RIPS 50 # factory RIPC SERIES Catalog 059 RIPC RIPC RIPC 50- Conductor Range Main Service Torque in. lb. # - 50 #6-4/0 85 Lbs Per 00 Pcs. Consult factory Insulation piercing - no need to strip the cable. Low installed cost and no special skills required. Shear-head screws guarantee proper torque every time. Environmentally sealed - completely watertight. Re-usable - services may be removed. Multiple applications - distribution, paralleling, service entrance and overhead. ITEM ITEM DISCONTINUED DISCONTINUED Southland Road, Ormond Beach, FL 74 Telephone:

150 TRADE PRICE SCHEDULE Effective February, 007 Aluminum Insulation Piercing Splice & Tap Connectors Shear-head bolt design Style - One Screw IPST SERIES Style - Two Screws Insulation piercing - no need to strip the cable. Low installed cost and no special skills or tooling required. Shear-head screws guarantee proper torque every time. Waterproof. Re-usable - services may be removed. Conductor Range Hex Bolt Torque Catalog Style # Main Tap Size in. lb IPST 0 * / IPST 00 * / IPST 00 / IPST 40 4/ / 0547 IPST 400 * /0-6 4/ IPST 4040 * 60 4/ IPST IPST / IPST / / IPST /0 4/ IPST / /0 5/ IPST File E50999 Multiple applications - overhead, above-grade URD service, street lighting, non-tension splicing and tapping, gutter taps. * Not UL listed. Includes blue adapter for use on bare cable. 46 Southland Road, Ormond Beach, FL 74 Telephone:

151 Tools & Accessories 47

152 48

153 TRADE PRICE SCHEDULE Effective February, 007 UT M Installation Tool Built in 5/8 die installs compression connectors from #8 to 4/0 Catalog 00 UT M Lightweight, only. pounds. Fast, one stroke of the tool develops full compression. Positive crimps, design assures proper compression before jaws will release. No dies to lose, 5/8" die is precision cast and machined as part of the tool. Backed by HMC's guaranteed maintenance program. UT Installation Tool For / and 5/8 compression connectors, with removable, reversable die Catalog 00 UT AVAILABLE UPPER DIES Catalog Description 00 UT -4 G / and 5/8 gold upper die for ACSR and Str. 0 UT -4 R / and 5/8 red upper die for compressed and compact Str. CONNECTORS INSTALLED WITH BOTH THE UT M AND UT TOOL Southland Road, Ormond Beach, FL 74 Telephone:

154 TRADE PRICE SCHEDULE Effective February, 007 UT 5 W Compression Tool & Accessories Die Retaining Spring Upper Die Catalog Description 004 UT 5 W Tool Rubber Insulated Lower Die Lower Die Locking Pin 005 UT 5 PB Protective Boot Pair of Replacement Wooden Handles / OD with handle castings UT 5 W Installing Head CP O Die Set CP D Die Set 00 H Upper Die Block 0 H Upper Die Block 0 H Lower Die Block 0 H 5 Upper Die Block 04 H 6 Upper Die Block 05 H 7 Lower Die Block Three pivot points allow complete compression with less handle force than single pivot point scissor type tools. Provides 5 tons compression force, yet weighs only 7.4 pounds. 'C' shape installing head design makes it easier to position and operate the tool. Equal Length Hardwood Handles INSTALLATION DIES Upper Die Catalog H I H Die Grooves TQ (/), TWTY, TD, TU (5/8) TS, TB, TJ, TLTN Lower Die Catalog H Upper Die Blocks Lower Die 'O' DIE SET CAT. NO. 470 CP 'D' DIE SET CAT. NO. 47 CP H 5 TX (840), TU H 7 H 6 TM, TR Installing die blocks for the UT5 tool have been designed to include various combinations of upper dies so that a minimum number of dies need to be ordered. ORDERED AS SETS Upper dies are furnished with four or two installing dies per block - in many cases, two upper die blocks with one lower die meet all installing requirements. 50 Southland Road, Ormond Beach, FL 74 Telephone:

155 TRADE PRICE SCHEDULE Effective February, 007 HM 50 Mechanical Single Indent Dieless Crimper Manually operated single-indent compression tool, for copper wire #8 to 50 kcmil, and aluminum wire #8 to 4/0 Catalog 0400 HM 50 Utility Cable Slicers For use on copper and aluminum cable only. Not to be used on steel or ACSR cable. Allen Wrench PVC dipped handle Catalog Description Insulating covers for the area where blades and handles are joined are available. Please consult the factory. Catalog Hex Size Maximum Conductor Size Max. OD inc. Insulation Overall Length (in.) 09 UT 4 C Cable Slicer - Small 600 Al - 50 Cu 5/6 00 UT 6 C Cable Slicer - Large 000 Al Cu / 0 UT 4 B Blade assembly for UT 4 C UT 6 B Blade assembly for UT 6 C Drop forged cutter blades and fiberglass handles are designed for easy field replacement. Fiberglass handles make a safe, rugged lightweight tool that will provide many years of dependable service. Slicing action of cutter blade provides flush, burr-free conductor ends. Handle stops prevent knuckle busting during operation WA 56 5/6 059 WA 8 /8 Southland Road, Ormond Beach, FL 74 Telephone:

156 TRADE PRICE SCHEDULE Effective February, 007 ROBO*CRIMP Battery Powered Dieless Crimping Tool Kits REC 60 REC 750 Catalog Connector Range 67 REC 60 # REC 750 #0-750 Both kits include: () battery powered tool () carrying strap () carrying case () BP-70R batteries () CH-TR 5 minute AC charger. ROBO*CRIMP is a registered trademark of Huskie Tools. ROBO*CRIMP Hand Operated Dieless Crimping Tools Catalog Connector Range 67 EP 60 # EP 750 #0-750 ROBO*CRIMP is a registered trademark of Huskie Tools. EP 60 EP Southland Road, Ormond Beach, FL 74 Telephone:

157 TRADE PRICE SCHEDULE Effective February, 007 UT5 Hydraulic Head & Accessories Installs full tension connectors for conductors up to 000 kcmil all aluminum, 50 kcmil hard drawn copper, and 954 kcmil ACSR (max. 7 steel strands). Catalog 07 UT 5 07 UT 5 N UT 5 UT 5 N This is the UT 5 hydraulic head with an impact-resistant PVC covering designed as added protection against accidental contact with energized conductors Carrying Case This is provided with each UT 5 tool. Additional cases may be ordered INSTALLATION DIES Catalog Description CAP Small Die Adapter C Series Large Dies CA Series Small (Adapter) Dies CA R Series Small (Adapter) Round Dies C R Series Large Round Dies CAO Small Die for O Size H-Taps 06 5 CAD Small Die for D Size H-Taps 06 5 CN Large Die for N Size H-Taps 06 5 CZ Large Die for Z Size H-Taps 9 0 Southland Road, Ormond Beach, FL 74 Telephone:

158 TRADE PRICE SCHEDULE Effective February, 007 Hydraulic Pumps & Crimping Head HPE 0000 HPG 0000 UT 60 Catalog Description 675 HPE 0000 Remote Control Electric Hydraulic 0,000 PSI Pump 676 HPG 0000 Gas Powered Hydraulic 0,000 PSI Pump 677 UT Ton Hydraulic Crimping Head HOM-OX Oxide Inhibitor & Thread Lubricant Catalog Description 6768 HM 5 Oxide inhibiting joint compound for full tension splices only. / pint (volume 8 fl. oz.) 6769 HM 5 44 HM TL 0 Oxide inhibiting compound for non-tension splices or pad to pad applications. / pint (volume 8 fl. oz.) Oxide inhibiting joint compound for overhead compression, partial tension splices, service entrance and pin terminals. / pint (volume 8 fl. oz.) Thread lubricant. / pint (volume 8 fl. oz.) 4 For larger container sizes, please consult the factory. Silicone Grease Catalog Weight Each 6770 HM 58.5 oz Southland Road, Ormond Beach, FL 74 Telephone:

159 TRADE PRICE SCHEDULE Effective February, 007 TOOL POLICY A. Mechanical Tools & Components. Warranty Hand tools are warranted for a period of one year against defects in material and workmanship. The warranty does not apply to tools which have been damaged by misuse or accident.. Tool Repair Only tools which are deemed defective in material and/or workmanship during the one year warranty period will be repaired (or replaced at our option). The customer pays the shipping costs back to HMC INDUSTRIES. HMC INDUSTRIES pays the shipping costs back to the customer. B. Hydraulic Tools & Components. Warranty Hydraulic tools are warranted for a period of one year against defects in material and workmanship. The warranty does not apply to tools which have been damaged by misuse or accident. Specifically excluded are hydraulic heads which have been damaged by operation dies.. Tool Repair Program The following tool repair program will exist for hydraulic tooling. a. Tools which are deemed defective in material and/or workmanship during the one year warranty periods will be repaired (or replaced at our option). Customer pays the shipping cost to HMC INDUSTRIES. HMC INDUSTRIES pays the shipping costs back to the customer. b. Tools which become inoperative beyond the warranty period will be repaired by HMC INDUSTRIES at the customer s expense. If in our estimation the cost to repair a tool exceeds 50% of the purchase price for a new tool (at the then-current list price) the customer will be advised and repairs delayed until authorization to proceed is received back from the customer. The customer pays shipping costs both ways. HMC INDUSTRIES sole obligation (and buyer s sole and exclusive remedy) for any breach of warranty under the foregoing warranty shall be to repair or, at HMC INDUSTRIES option to replace FOB the original point of delivery and goods which are nonconforming or defective and are so specified by buyer in a written certified mail notice to an officer of HMC INDUSTRIES within 90 days after receipt of such goods by buyer. Buyer expressly disclaims any and all express or implied warranties other than the warranty of its title to goods and the warranty herein above set forth. Such disclaimer includes with limitation, warranty of fitness for a particular purpose and warranty of merchantable quality Southland Road, Ormond Beach, FL 74 Telephone:

160 56

161 TRADE PRICE SCHEDULE Effective February, 007 TERMS & CONDITIONS OF SALE PAYMENT TERMS % 5 th prox, net 0 days. Payment terms for special quotes are net 0 days unless stated otherwise on the quotation. Interest will be charged at the rate of ½% per month on invoices unpaid after 0 days. FREIGHT TERMS A. All shipments will be made F.O.B. shipping point with freight costs being collect, prepaid and added or prepaid and allowed. Shipments are freight allowed on orders of $500 net value or more to delivery points within the continental USA using standard shipping methods and service. B. Buyer is responsible for filing claims for damage, shortages or losses in shipment with the carrier. C. Air shipments are provided upon Buyer request with Buyer responsible for all transportation charges. PRICES A. All prices are subject to change without notice. Orders will be billed at prices in effect at time of shipment, including orders scheduled for shipment at a future date. MINIMUM ORDER SALES TAX DELIVERY EXCEPTIONS. Back ordered materials on orders received prior to the effective date of a price increase will be billed at prices in effect at time of order for a period of 60 days following the effective date.. Orders held firm by a HMC INDUSTRIES quotation number for non-cancelable, scheduled or contract orders will be billed at prices in effect at time of order. These prices will be held firm for a period not to exceed six months from the effective date of the price increase. This exception does not apply to general blanket orders that do not contain specific item quantities and firm scheduled ship dates. B. Orders will be billed at applicable column prices in accordance with the quantity purchased. C. Purchase orders must reference a current quotation number and quoted prices to receive quoted discounts. Failure to include this information will result in orders charged at standard pricing. D. Requests to add items to orders in process, in production or in which a shipment has been made will be accepted on terms applicable to the addition only. A minimum net charge of $00.00, plus freight charges, is applicable for any single order. HMC INDUSTRIES reserves the right to add to the sales price any tax imposed by law on the sale of any product. Orders not under specific quotation must permit shipment within 0 days from the date of order or at the factory s convenience Southland Road, Ormond Beach, FL 74 Telephone:

162 TRADE PRICE SCHEDULE Effective February, 007 TERMS & CONDITIONS OF SALE (continued) CLAIMS DELAY RETURNS WARRANTY PACKAGING & CARTON QUANTITIES SPECIAL ORDERS CANCELLATIONS Claims for shortages, erroneous charges or price corrections shall be deemed waived unless made in writing to HMC INDUSTRIES within 7 days of invoice. All quotations and agreements as to shipment or delivery dates and other matters, including estimation of all delivery dates are subject to current and future Federal and State laws, rulings and regulations. HMC INDUSTRIES will not be responsible for any delay in performance due to strikes, labor stoppages, supplier conditions, embargoes, accidents, delays in transportation, shortage of fuel, labor or materials, fires, floods or other acts of God, and all other causes beyond the reasonable control of HMC INDUSTRIES. No material may be returned without the Seller s consent. Permission to return goods must be obtained from HMC INDUSTRIES in writing through the local representative. HMC INDUSTRIES products are warranted to be free from defects in material and workmanship for one () year from the date of shipment. As it is impossible to detect all imperfections and to control field application, the Buyer s sole and exclusive remedy for breach of this warranty is expressly limited. HMC INDUSTRIES may, at HMC INDUSTRIES sole option repair or replace only such goods as prove defective. Under no circumstance will HMC INDUSTRIES be liable for damages, costs or losses beyond the price of the goods. HMC INDUSTRIES shall not be liable for any incidental, direct, indirect or consequential damages caused by breach of the warranty. This warranty applies provided that conditions of operation, installation and application have been as specified and/or recommended by the manufacturer and provided that the product has not been subject to abnormal stresses. This warranty does not cover damage in shipment. Claims for damage in shipment should be made to the carrier in accordance with the Seller s Freight Terms. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR ORAL INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Prices quoted include HMC INDUSTRIES standard packaging unless otherwise indicated on the quotation. For special packaging, consult the factory. HMC INDUSTRIES reserves the right to round to the standard carton for items shipping to regular ship-to locations for make-to-stock items. Make-to-order items are subject to minimum order quantities and are non-cancelable and non-returnable. Orders for special make-to-order items may be shipped and charged above or below the quantity ordered and may then be considered complete. Although HMC will endeavor to make the actual quanity ordered. Buyer may cancel an order prior to shipment but the Buyer is liable for reimbursing the Seller for work performed, including labor and overhead costs and materials used. Special orders and/or make-to-order items may not be cancelled. 58 Southland Road, Ormond Beach, FL 74 Telephone:

163 Homac Mfg. Company Ormond Beach, FL Southland Road, Ormond Beach, FL 74, USA Telephone: Fax: Made in USA

Insulated Street and Highway Lighting Mechanical Connectors Insulated connectors for above-ground applications.

Insulated Street and Highway Lighting Mechanical Connectors Insulated connectors for above-ground applications. Lighting Mechanical Connectors Insulated Lighting Mechanical Connectors Insulated connectors for above-ground applications. Rubber Insulation Ensures an insulated connection. Models with Street Light Connectors

More information

Homac. Underground Distribution. Table of Contents

Homac. Underground Distribution. Table of Contents Table of Contents Direct-buried, underground systems come with an ever-present challenge: How do you keep water out of the connections? Thomas & Betts has the products you need to make watertight splices

More information

Our overhead products go above and beyond all others. QUICK REFERENCE. Overhead Connectors. & Covers. Overview

Our overhead products go above and beyond all others. QUICK REFERENCE. Overhead Connectors. & Covers. Overview Overview QUICK REFERENCE Overhead Connectors & Covers page(s) Our overhead products go above and beyond all others. We have plenty of overhead connectors. From transformer eyebolts and stirrup connectors

More information

Underground Distribution

Underground Distribution Aluminum Flood-Seal TM Mechanical Connectors Save outlet space These connectors feature the Sweetheart TM outlet configuration that nests two equal-sized service cables from #6 to 2/0 or two different-sized

More information

Underground Distribution

Underground Distribution Aluminum Universal Quick Disconnect Transformer Connectors The EZ Mount connector is used on padmount distribution transformers that have a 5/8 in. or 1 in. secondary bushing stud one mounting hole accepts

More information

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).

More information

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 32000 GL 80 32002 GL 84 3999 GL 0 32004 GL 4 3200 GL 5 32003 GL 38

More information

Homac. Underground Distribution. Pedestal Connectors and Covers. Aluminum Lay-In Pedestal Connectors

Homac. Underground Distribution. Pedestal Connectors and Covers. Aluminum Lay-In Pedestal Connectors Aluminum Lay-In Pedestal Connectors Effortlessly install or remove large, stiff cables in confined areas Minimizes the hassle and hazards of having to force cables into the closed cable ports found on

More information

DISTRIBUTION CONNECTORS SECTION DF COMPRESSION TERMINALS. Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs

DISTRIBUTION CONNECTORS SECTION DF COMPRESSION TERMINALS. Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs DISTRIBUTION CONNECTORS COMPRESSION TERMINALS Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs SECTION VERSAtile ALUMINUM COMPRESSION TERMINAL TYPE VCEL For use with either

More information

CTN QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473. Two-Hole NEMA CTN QTY

CTN QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473. Two-Hole NEMA CTN QTY PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 2000 2002 998 999 2004 200 200 2005 200 2008 207 2007 2009 200 20

More information

SUBMERSIBLE SECONDARY CONNECTORS

SUBMERSIBLE SECONDARY CONNECTORS SUBMERSIBE SECONDARY CONNECTORS TYPE SSBC350- (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEA RUS Approved User friendly wide-port spacing (50% more room for cable training). Multiple

More information

Connector Installation Guide Compression and Mechanical Connectors

Connector Installation Guide Compression and Mechanical Connectors Connector Installation Guide Compression and Mechanical Connectors Typical Cross Section of a Compression Connector Before Installation Before compression, a typical cross section of cable consists of

More information

CP 600V Cable Protectors

CP 600V Cable Protectors Protecrs Mersen CP Protecrs are special purpose limiters which are crimped or bolted cables or terminals clear and isolate faults quickly, increasing the reliability of service entrance and distribution

More information

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet Quick Term II Cold Shrink Silicone Rubber Termination Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 15 kv Class 110 kv BIL Kit Contents: 1 Hi K Silicone Rubber Termination 2 Scotch 70 Silicone

More information

Aluminum Mechanical Lugs

Aluminum Mechanical Lugs luminum Mechanical ugs MNI INUSTRI ONNTORS One- and Two-onductor luminum ugs Suitable for use with either copper or aluminum conductors Manufactured from high strength 6061-T6 aluminum alloy lectroplated

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

CT Metering. CT Metering. Meter Mounting Equipment

CT Metering. CT Metering. Meter Mounting Equipment Single Meter Sockets, Without Bypass - CT Rated.................................. 67-68 Single Meter Sockets, CT Rated With Test Switch Bypass Provision............. 69-70 Meter Socket / Enclosure Combination

More information

10. ACCEPTED EQUIPMENT

10. ACCEPTED EQUIPMENT 10. ACCEPTED EQUIPMENT 10.1 GENERAL In order to meet the minimum specifications of these Electric Service Requirements, certain equipment shall have the acceptance of the Company. Manufacturers of equipment

More information

Open-Style Power Distribution Blocks

Open-Style Power Distribution Blocks I MPDB Series Open-Style Power Distribution Blocks The Next Generation Power Distribution Block (PDB) Ratings: Volts: 1000Vac/DC Amps: 65 to 2260A based on NEC table 310.15(B)(16) 75ºC ampacities Mersen

More information

Bonding & Grounding. Telecommunications Main Ground Bars. Telecommunications Main Ground Bar Kits

Bonding & Grounding. Telecommunications Main Ground Bars. Telecommunications Main Ground Bar Kits PhysicalSupport.D 1/21/08 2:10 PM Page 121 GB4X12TMGB GB4X20TMGB GB4X12TMGBKIT Telecommunications Main Ground Bars and Kits Manufactured of 1/4 thick electrolytic tough pitch 110 alloy copper bar. Includes

More information

No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together Recognized by UL and cul STATES Type have

More information

3SE03 North American Limit Switches

3SE03 North American Limit Switches General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.

More information

Lithium-Ion Battery-Powered Tools

Lithium-Ion Battery-Powered Tools Lithium-Ion Battery-Powered Tools Thomas & Betts. Your best connection for innovative solutions. Wire & Cable Management Cable Protection Systems Power Connection & Control S a f e t y Te c h n o l o g

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications Step One Preparing the Cable Strip the insulation carefully to avoid nicking or cutting conductors

More information

BURNDY Compression. TWO HOLE HYLUG CODE CONDUCTOR STANDARD BARREL (Continued) Fig. 1 Fig. 2 Fig. 3. Conductor

BURNDY Compression. TWO HOLE HYLUG CODE CONDUCTOR STANDARD BARREL (Continued) Fig. 1 Fig. 2 Fig. 3. Conductor URNDY TWO HOLE HYLUG CODE CONDUCTOR STANDARD ARREL (Continued) T T T Fig. 1 Fig. 2 Fig. 3 C-46 Conductor Installation Tooling Stud Stud Figure Mechanical Hydraulic Wire Fig *** Hole Hole Tongue Dimensions

More information

Type Termination Cable Size Copper Aluminum 2 CP2C1-1/0 CP1/0C1-2/0 CP2/0C1-4/0 CP4/0C1 CP4/0A1. Cable 250kcmil CP250C3 CP250A3

Type Termination Cable Size Copper Aluminum 2 CP2C1-1/0 CP1/0C1-2/0 CP2/0C1-4/0 CP4/0C1 CP4/0A1. Cable 250kcmil CP250C3 CP250A3 C 600V rotectors ECIL UROE Description # for Type Type Termination ize Copper luminum 2 C2C1-1/0 C1/0C1-2/0 C2/0C1-4/0 C4/0C1 C4/01 250kcmil C250C1 C2501 1 to 350kcmil C350C1 C3501 400kcmil C400C1-500kcmil

More information

Jumper Terminals and Tee Taps. delivery

Jumper Terminals and Tee Taps. delivery Jumper Terminals and Tee Taps delivery November 017 November 017 Jumper Terminals & Tee Taps Index Compression/Aluminum JTS... Straight Pad for AAC, AAAC, ACAR & ACSR Conductor... -1 JTF... 15 Degree Pad

More information

B T T T 2.11 MY29-11 (1) 4/0 AWG - MY29-11 (1) W30VT (2) U30RT (2) 300 kcmil 150 W30VT (2) YA30L-2TC W30RT (2) U28ART (2)

B T T T 2.11 MY29-11 (1) 4/0 AWG - MY29-11 (1) W30VT (2) U30RT (2) 300 kcmil 150 W30VT (2) YA30L-2TC W30RT (2) U28ART (2) URNDY TWO HOLE HYLUG CODE CONDUCTOR STANDARD ARREL (Continued) T T T Fig. 1 Fig. 2 Fig. 3 Conductor Installation Tooling Stud Stud Figure Mechanical Hydraulic Wire Fig *** Hole Hole Tongue Dimensions Dieless

More information

Open-Style Power Distribution Blocks

Open-Style Power Distribution Blocks MPDB Series Open-Style Power Distribution Blocks Power distribution The Next Generation Power Distribution Block (PDB) Ratings: Volts: 000VAC/DC Amps: 65 to 2260A based on NEC table 30.5(B)(6) 75ºC ampacities

More information

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief) Instructions Quick Term II Silicone Rubber Termination (with High-K Stress Relief) IEEE Std. No. 48 990 Class Termination 5 kv Class 50 kv BIL Kit Contents Hi K Silicone Rubber Termination Scotch 70 Silicone

More information

Type SJK Test Switches

Type SJK Test Switches Type SJK Test Switches No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together DESCRIPTION STATES

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief 3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief 7642-S-2, 7642-S-2(L) For Jacketed Concentric Neutral (JCN) and Concentric Neutral (CN) Cable Instructions IEEE Std.

More information

PRODUCT SHEET. Elastimold advanced connection system (shear bolt)

PRODUCT SHEET. Elastimold advanced connection system (shear bolt) PRODUCT SHEET Elastimold advanced connection system (shear bolt) 2 Elastimold cable accessories The Elastimold advanced connection system - shear bolt is the latest solution to be incorporated into the

More information

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS Transmission: Section 1 NOMENCLATURE Single Support and Double Support : Identified by S and D appearing in the length column on the catalog page. Should the maximum distance between tied supports exceed

More information

TERMINATION ENCLOSURE OPTIONS

TERMINATION ENCLOSURE OPTIONS TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated

More information

CONNECTORS AND FITTINGS

CONNECTORS AND FITTINGS Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. Human photo.

More information

Installation, Maintenance & Parts Manual

Installation, Maintenance & Parts Manual Installation, Maintenance & Parts Manual 2100 Series Center Drive Conveyors Table of Contents Warnings General Safety........................... 2 Introduction....................................... 2

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W TYPE GAR D-28 FENCE POST GROUNDING CONNECTOR For Parallel or 90 Copper Cable Connection To Rod or Pipe with the Same Connector High copper alloy ground connector for joining a range of cable, parallel

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

PRODUCT BROCHURE. Elastimold advanced connection system (shear bolt)

PRODUCT BROCHURE. Elastimold advanced connection system (shear bolt) PRODUCT BROCHURE Elastimold advanced connection system (shear bolt) 2 ELASTIMOLD ADVANCED CONNECTION SYSTEM (SHEAR BOLT) Elastimold cable accessories The Elastimold advanced connection system shear bolt

More information

3SE03 North American Limit Switches

3SE03 North American Limit Switches General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.

More information

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features: Issue Date: 07/17/2017 Page: 1 of 5 PSS- K656LR Elbow Connector (with Test ) Applications: The Elastimold K656LR (with test point) is designed to provide fully shielded, dead-front submersible cable connections

More information

G R E E N L I T E. c a b l e a c c e s s o r y c o r p o r a t i o n

G R E E N L I T E. c a b l e a c c e s s o r y c o r p o r a t i o n G R E E N L I T E c a b l e a c c e s s o r y c o r p o r a t i o n G R E E N L I T E c a b l e a c c e s s o r y c o r p o r a t i o n GT Nylon Cable Ties 4 GT Nylon Cable Ties - Color 5 GS Screw-Mount

More information

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SECTION 500 METERING AND ASSOCIATED EQUIPMENT SECTION 500 METERING AND ASSOCIATED EQUIPMENT 500.0 General Meter sockets shall be provided, installed and maintained by Customer. When the ratings of meter sockets are exceeded, transockets shall be used.

More information

Stud connection system HSK

Stud connection system HSK CONTA-CONNECT system HSK The newest generation of stud terminals from CONTA-CLIP offers secure connections for all energy-transmitting applications. Depending on the conductor cross-section, stud terminals

More information

READY REFERENCE GUIDE

READY REFERENCE GUIDE ENERGY /// ENERGY REAY REFERENCE GUIE REAY REFERENCE GUIE Generation istribution Transmission Who is TE? We are a reliable provider of energy solutions for any environment. With a focus on employee expertise

More information

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company

More information

your Green Power WIND POWER SOLUTIONS only Greener

your Green Power WIND POWER SOLUTIONS only Greener your Green Power WIND POWER SOLUTIONS only Greener WIND POWER SOLUTIONS Thomas & Betts is committed to being your partner in power delivery by leading the industry in innovative wind power solutions and

More information

Heavy Duty Copper Battery Terminals

Heavy Duty Copper Battery Terminals Heavy Duty Copper Battery Terminals Constructed of 131 contact copper to provide high conductivity. Raised characters to ensure legibility of important information regarding cable size, post type, and

More information

SERIES POWER DISTRIBUTION BLOCKS

SERIES POWER DISTRIBUTION BLOCKS 62000-69000 SERIES POWER DISTRIBUTION BLOCKS VERSATILE POWER DISTRIBUTION BLOCKS FOR CABLE TERMINATIONS Ferraz Shawmut Power Distribution Blocks afford a safe, convenient way of splicing cables, splitting

More information

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG Noise calculation model: ISO 9613-2 General Wind speed: 8,0 m/s Ground attenuation: General, Ground factor: 0,4 Meteorological coefficient, C0: 0,0 db Type of demand in calculation: 1: WTG noise is compared

More information

POWR-BLOKS. POWR-GARD Blocks and Holders Datasheet. Distribution Blocks Splicer Blocks Covers. Connectors. Ampere Ratings. Description.

POWR-BLOKS. POWR-GARD Blocks and Holders Datasheet. Distribution Blocks Splicer Blocks Covers. Connectors. Ampere Ratings. Description. Distribution Blocks Splicer Blocks Covers Connectors Box lug connectors are designed for use with a single or multiple, solid or class B or C stranded conductor. For UL approved use of more than one conductor

More information

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254. 3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200

More information

Fuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series

Fuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series Fuse & Switch Product Facts High Density n Fuse and Switch rated 15A and 300V. n High Density 0.36" [9.14] centerline spacing saves panel space; at least 33 circuits per foot. Fuse n Provide in-line circuit

More information

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES TELECOMMUNICATIONS SPECIAL PURPOSE FUSES Ferraz Shawmut telecommunications fuses are specially designed for the protection of telecommunications equipment which includes telephone switching equipment,

More information

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit 3M Cold Shrink QTIII Silicone Rubber Skirted Termination Kit With HighK Stress Relief 3M Cold Shrink QTIII Silicone Rubber Skirted Termination Kit With HighK Stress Relief For Jacketed Concentric Neutral

More information

TRADING CO., INC. AUTOMOTIVE ELECTRICAL SUPPLIES. We carry a full line of electrical supplies and primary wire! Call today!!

TRADING CO., INC. AUTOMOTIVE ELECTRICAL SUPPLIES. We carry a full line of electrical supplies and primary wire! Call today!! & TRADING CO., INC. WWW.DYNATRONINDUSTRIES.COM AUTOMOTIVE ELECTRICAL SUPPLIES & TRADING CO., INC. 63 AUSTIN BLVD COMMACK NY 11725 TEL: (631)543-4490 FAX (631)543-4496 TOLL FREE: 1-800-669-3962 We carry

More information

Power Distribution Blocks

Power Distribution Blocks ower istribution Blocks A OWERFUL WAY TO MANAGE YOUR OWER ISTRIBUTION CHALLENGES Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or the compatibility

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

REV: 000. Super Seca Flash Cure Units

REV: 000. Super Seca Flash Cure Units REV: 000 Super Seca Flash Cure Units Table Of Contents Introduction 2 Standard Operating Guide 2 Features & Specs 2 External Layout 4-15 Internal Layout 16-24 Plug Guide 25 Wiring Diagrams 26-28 F.A.Q.

More information

AS/ASH SERIES ALUMINUM PNEUMATIC AND HYDRAULIC CYLINDERS... 6

AS/ASH SERIES ALUMINUM PNEUMATIC AND HYDRAULIC CYLINDERS... 6 AS/ASH SERIES ALUMINUM PNEUMATIC AND HYDRAULIC CYLINDERS............. 6 Section 6 8 ORDERING INFORMATION For Rod End Dimensions see back cover foldout... Basic Cylinder No Mount.0" to 4.00" For pressure

More information

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

LB125A 1-1/4 LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LB125A 1-1/4" LB Form 5 Aluminum Conduit Body Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit

More information

In This Section. and. Fittings & Non-Metallic Rigid Conduit Fittings and Accessories. Steel City Fittings

In This Section. and. Fittings & Non-Metallic Rigid Conduit Fittings and Accessories. Steel City Fittings In This Section and Steel City Overview...F-2 F-3 Thinwall Conduit (EMT)...F-4 F-9 Rigid/Intermediate Grade Conduit...F-0 7 Flexible Cord and Power Cable Connectors...F-8 Liquidtight Flexible Metal Conduit

More information

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223 METRIC (IEC) FRAME THYRISTOR RATED DC METRIC (IEC) FRAME MOTORS IP54 These metric dimensioned motors are built to IEC 34-1 electrical and mechanical standards. The IEC 63 and smaller frames are stocked

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High

More information

POWR-BLOKS. POWR-GARD Blocks and Holders Datasheet. Distribution Blocks Splicer Blocks Covers. Connectors. Ampere Ratings. Description.

POWR-BLOKS. POWR-GARD Blocks and Holders Datasheet. Distribution Blocks Splicer Blocks Covers. Connectors. Ampere Ratings. Description. Distribution Blocks Splicer Blocks Covers Connectors Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one con ductor per connector opening

More information

Underground Bus Bar Distribution System 03 SEP 13 Rev B

Underground Bus Bar Distribution System 03 SEP 13 Rev B Application Specification 114-24006 Underground Distribution System 03 SEP 13 NOTE NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters

More information

Wind Power Solutions. Make Energy Renewable and Reliable!

Wind Power Solutions. Make Energy Renewable and Reliable! Wind Power Solutions Make Energy Renewable and Reliable! Reliable Thomas & Betts Products for Clean, Green, Thomas & Betts makes all the products that connect and protect a wind farm and its power distribution

More information

Specialty Electrical Supplies and Tools

Specialty Electrical Supplies and Tools Specialty Electrical Supplies and Tools Connectors Terminals Tools Battery Accessories Circuit Protection Cable Ties & Accessories San Diego, California Office Phone 619.278.1302 * Fax: 619.542.9994 Electrical

More information

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Class R 250V and 600V modular ferrule and knifeblade fuse blocks Technical Data 1048 Class R 2V and 600V modular ferrule and Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with up to four mounting holes per pole

More information

PROFESSIONAL MODULAR CRIMPS, STRIPS & CUTS TOOL

PROFESSIONAL MODULAR CRIMPS, STRIPS & CUTS TOOL PROFESSIONAL MODULAR CRIMPS, STRIPS & CUTS TOOL Tool 200A/200AR design with 10 position punches. For crimping 8P8C plug, please use AMP 8p8c plug with 2 extra cavities on each side as Fig. 1. Tool 2008A/2008AR

More information

Anti-Rotational Connectors No-turn design keeps connector securely in place even under vibration. Anti-Rotational Connectors

Anti-Rotational Connectors No-turn design keeps connector securely in place even under vibration. Anti-Rotational Connectors Anti-Rotational Connectors No-turn design keeps connector securely in place even under vibration. Anti-Rotational Connectors Blackburn Anti-Rotational Connectors are designed with a rib on the bottom that

More information

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits 3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits With High Ampacity Ground Connection and High-K Stress Relief For Tape Shield, Wire-Over-Tape Shield and Longitudinally Corrugated (LC) Shield

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

SYSTEM PROTECTION - PLATING

SYSTEM PROTECTION - PLATING INTRODUCTION 1. Plates F1 thru F10 supply only the material required for one-phase. Therefore, for threephase construction, you will be required to call for the specified plate three times at that station.

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

DK-LOK Hydraulic Pipe Fittings

DK-LOK Hydraulic Pipe Fittings Class 2000, 3000, 6000, 9000 fittings Catalog No. C-2 June 2012 DK-LOK Hydraulic Pipe Fittings are designed and manufactured to the following standards. ASME B 16.11-2005: Forged fittings, Socket-welding

More information

High barriers Recognized by UL and cul Self-extinguishing materials Nonferrous material Corrosion-resistant nickel finish Safety-grip handle A complete line of switches is available for meter, relay, instrument,

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

GROUNDING & BONDING PRODUCTS

GROUNDING & BONDING PRODUCTS GROUNDING & BONDING PRODUCTS Busbars Page 5-3 Insulators Page 5-8 Grounding Products Page 5-9 Compression Tools, Lugs & Taps Page 5-14 Learn About CPI s Extended Limited Warranties for coverage of (2)

More information

Medium Duty 1.5 ~ 4 Bore 12 Different NFPA Mounting Options Non-Rotating Option Tandem Cylinder Option Auto Switch Capable

Medium Duty 1.5 ~ 4 Bore 12 Different NFPA Mounting Options Non-Rotating Option Tandem Cylinder Option Auto Switch Capable N304 Air Cylinder NCA1 Series NFPA Interchangeable Medium Duty 1.5 ~ 4 Bore 12 Different NFPA Mounting Options Non-Rotating Option Tandem Cylinder Option Auto Switch Capable NFPA Interchangable Air Cylinder

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs...

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs... Power Distribution Blocks I A powerful way to manage your power distribution challenges. Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or

More information

Voltage Rating Current Rating Material. Connector. Catalog/ ordering number. Catalog/ ordering number. 1 of 6

Voltage Rating Current Rating Material. Connector. Catalog/ ordering number. Catalog/ ordering number. 1 of 6 Distribution Blocks Splicer Blocks Covers Description POWR-BLOKS TM power distribution blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point or splitting primary

More information

POWR-BLOKS. POWR-GARD Blocks and Holders Datasheet. Distribution Blocks Splicer Blocks Covers. Connectors. Ampere Ratings. Description.

POWR-BLOKS. POWR-GARD Blocks and Holders Datasheet. Distribution Blocks Splicer Blocks Covers. Connectors. Ampere Ratings. Description. Distribution Blocks Splicer Blocks Covers Connectors Box lug connectors are designed for use with a single or multiple, solid or class B or C stranded conductor. For UL approved use of more than one conductor

More information

CABINET OPTIONS AND DESIGNATORS CODE LETTERS

CABINET OPTIONS AND DESIGNATORS CODE LETTERS CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:

More information

Cam-Lok Single Pole Connectors

Cam-Lok Single Pole Connectors Cam-Lok Single Pole Connectors Cooper Interconnect Cam-Lok Single Pole Connectors are specially designed to provide the ultimate in reliable service, even under the most severe operating conditions. These

More information

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33 SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9

More information

Voltage Rating Current Rating Material. Connector CATALOG/ ORDERING NUMBER CATALOG/ ORDERING NUMBER. 1 of 6

Voltage Rating Current Rating Material. Connector CATALOG/ ORDERING NUMBER CATALOG/ ORDERING NUMBER. 1 of 6 Distribution Blocks Splicer Blocks Covers Description POWR-BLOKS TM power distribution blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point or splitting primary

More information

PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY

PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY connectorproducts.com 1300 John Tipton Blvd. Pennsauken, NJ 08110 Phone: 856.829.9190 Fax: 856.829.9195 Catalog IX.1 American Design American Made Our success

More information

Accessories, Splices and Connectors

Accessories, Splices and Connectors 10.137 Accessories, Splices and Connectors Splices and Connectors Pgs. 137-142 Misc. Accessories Pgs. 143 Ground Connectors Pg. 144 Separators Pgs 145 For more information or to order, call 1-800-277-4810

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Covers for Cast Iron or Aluminum Device Boxes

Covers for Cast Iron or Aluminum Device Boxes Single Gang Blank cover for enclosing splices and taps where device not used. Sheet DS100 Flush Sheet steel DSS100 For GFI receptacles. Sheet steel DS23 GFI For square handle general use snap or toggle

More information

Specification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings...

Specification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings... SECTION D INDEX Product Description Page Number Specification Grade Insulated Bushings.....................DA Specification Grade Insulated Grounding Bushings........DA2-DA4 Insulating Bushings & Couplings.......................DA-DA6

More information

PRODUCTS FOR UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS

PRODUCTS FOR UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS PRODUCTS FOR UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS For over 70 years, BURNDY has pioneered and produced economical, dependable connectors and protective devices for urban underground distribution

More information