Maximum R.M.S continuous current through IN - rated current fuses ( A ) Catalog Number MR10RESSORT.

Size: px
Start display at page:

Download "Maximum R.M.S continuous current through IN - rated current fuses ( A ) Catalog Number MR10RESSORT."

Transcription

1 MR 0 CI MR 0 MR - MR 0. Clips MR - MR 7 MR For Ferrule style Fuses ø SILVER-PLATED COPPER CLIPS: EXTREMELY HIGH THERMAL AND ELECTRIC CONDUCTIVITY MOUNTING TYPE: - SCREWING ON ISOLATORS - SCREWING ON BARS OR INSULATED BARS - WELDING ON P.C.B. (MR 0 CI) STAINLESS STEEL PRESSURE SPRINGS: HIGHLY RESISTANT TO SALT SPRAY Main Characteristics Designation MR 0 MR 0 CI MR MR 0 MR MR 7 MR Current rating IN( A ) 5 5 Maximum R.M.S continuous current through IN - rated current fuses ( A ) 5 5 Recommended copper cable section (mm ) MR 0 - MR 0 CI Catalog MR0RESSORT Designation MR 0 Ref. B09800 Weight (g) 7 Packaging 0 pieces 0. Catalog MR0RESSORTSP Designation MR 0 without connection Ref. C09899 Weight (g) 5,7 Packaging 0 pieces 9 Ø Catalog MR0RESSORTCI Designation MR 0 CI Ref. Y0987 Weight (g),5 Packaging 00 pieces FG7 /0

2 Clips For Ferrule style Fuses ø MR.5 Catalog MRSPRING Designation MR Ref. G09870 Weight (g) Packaging 0 pieces Ø.5 Ø.5 MR Catalog MR0RESSORT Designation MR 0. Ref. H Weight (g) 0 Packaging 0 pieces Ø.5 Ø.5 MR 7.5 Catalog MRSPRING Designation MR Ref. K0989 Weight (g) 0 Packaging 0 pieces Ø.5 Ø.5 MR 7 9. Catalog MR7RESSORT Designation MR 7 Ref. Y097 Weight (g) Packaging 0 pieces Ø 8 Ø.5 /0 FG75

3 Clips MR Ø 8.5 Ø.5 Catalog MRR Designation MR Ref. M0975 Weight (g) 85 Packaging piece All clips silver-plated copper with stainless steel springs. Mounting Instructions P.C.B. Drilling for MR0 CI clip (0 X 8 Size Fuse).7 to Clip Mounting x holes ø L A Alignment Fixing in position holes ø mm Fuse size 0 x 8 x 5 x 58 0 x 5 0 x 7 0 x 7 x 0 x 7 x A L Mounting of two elastic stop pins of mm dia. for fixing clips in position FG7 /0

4 SI SI SI with microswitch SI Bases for x5, x58 For Ferrules-type fuses Ø - SHOCK-PROOF MODULAR ASSEMBLY COMPLIANT WITH IEC 09- AND NF C 0 BASE MOUNTING WITH OR WITHOUT MICROSWITCH AND ISOLATING PARTITION PHENOLIC RESIN FOR BASIC APPLICATIONS (BASIC MODEL) SELF-EXTINGUISHABLE FIBERGLASS POLYESTER FOR TRACTION AND CORROSIVE ATMOSPHERE APPLICATIONS (SALT SPRAY-PROOF MODEL) Main Characteristics Model Phenolic resin (standard) SI SI Thermal current rating (Ith) A 5 A Maximum power losses W per phase W per phase Rated insulation voltage Ui AC or DC according VDE 00:55 - group C withstand 7 V Dielectric withstand tests R.M.S. voltage mn - 0 Hz 8 kv between phase and mass Voltage shock./µs Uimp. : impulse voltage as per IEC 097- between phase and mass Salt-spray proof fiber glass polyester SKI SKI A 5 A W per phase W per phase 7 V kv between phases and microswitch Connecting with mm max. width, 5mm max. thick terminal for SI and mm max. for SI * Only for the base. Accessories (partitions and microswitches) are not classified due to their lightness. between phases and microswitch Tests according to IEC 000 and 09 and NF C 00 Dry atmosphere and new fusegear Basic model Max. temperature ( C)/Relative Humidity (%): 0 C/95% - 0 C/80% - C/% If Holder must be kept off, a heating system fed during stop periods must be used. Purpose is to keep the temperature of cubicle at a level slightly higher than outdoor. Salt spray-proof model Moist tropical and equatorial climate. Corrosive atmosphere. SI and Partition wall 5 M Designation Ref. Catalog Weight (g) ø SI SKI Pack: pieces V 097 B 0970 SI: basic model - SK salt spray-proof model SI SKI Partition wall Designation Ref. Catalog Weight (g) 8 0 E - B E- For direct mounting, screw tightening torque = 0. mdan Pack: pieces FG78 /0

5 SI Bases for x5, x58 For Ferrules-type fuses Ø - SI and Partition wall M Designation Ref. Catalog Weight (g) ø SI SKI Pack: pieces Partition wall W0975 C097 SI: basic model - SK salt spray-proof model SI SKI 0 Designation Ref. Catalog Weight (g) 5 E - Pack: pieces B E- 0 8 For direct mounting, screw tightening torque = 0. mdan Remote sensing microswitch Microswitch type for SI Code Ref. Catalog Weight (g) Basic single microswitch salt spray-proof single microswitch Basic twin microswitch MC -5 FL -5 MCK -5 FL -5 MC -5 FL -9 D 05 T 0975 P Microswitch type for SI Code Ref. Catalog Weight (g) Basic single microswitch salt spray-proof single microswitch Basic twin microswitch MC -5 FL -5 MCK -5 FL -5 MC -5 FL -9 H055 R097 T05 0 Pack: piece POSSIBLE ASSEMBLING AFTER CONNECTING ON MODEL WITHOUT PARTITION WALL With manual reset reversing style microswitch 0A - V cos ϕ = 0. # and terminals must always be connected. Adapters for DIN-rail mounting Rail style Designation Ref. Cat. Top part Bottom part Color Weight (g) Pkg. Asymmetrical DIN EN 05 Symmetrical DIN EN 0 EF EF 5 EF Fixoméga FM L G 0970 K 0970 B 09 EF EF5 EF MIFIXOMEGAFM vis M vis M vis M vis M 5 vis M M center screw blue cream white stainless steel /0 FG79

6 CC, CCR CC 8x fuse holder Ith max. 5A - Un 00V for 8x fuses with or without blown-fuse indicator For Ferrule-type Fuses Ø Model with no indicator light Model with no indicator light screw-on rail mounting Poles Ref. Cat. Ref. Cat. Nb Mod N Y CC8N C797 CC8NR E5 CC8 M8 CC8R +N G55 CC8N Q9 CC8NR L CC8 R9780 CC8R L70 CC8 C58 CC8R +N Z788 CC8N V980 CC8NR CC 0x8 fuse holder Ith max. A - Un 0V for 0x8 fuses with or without blown-fuse indicator or striker Model with no indicator light Model with no indicator light screw-on rail mounting Poles Ref. Cat. Ref. Cat. Nb Mod N Y0 CC0N W CC0NR S570 CC0 F57 CC0R +N Y08 CC0N M5 CC0NR N0 CC0 M7 CC0R A8 CC0 A789 CC0R +N S7 CC0N D798 CC0NR CC x5 fuse holder Ith max. A - Un V for x5 fuses with or without blown-fuse indicator or striker Model with no indicator light Model with no indicator light screw-on rail mounting Poles Ref. Cat. Ref. Cat. Nb Mod N R95 CCN C087 CCNR,5 S978 CC Z07 CCR,5 +N D59 CCN T57 CCNR W98 CC Z08 CCR D00770 CC P0 CCR,5 +N V0 CCN B9 CCNR FG80 /0

7 CC, CCR For Ferrule-type Fuses Ø Ith max. 5A - Un V for x58 fuses with or without blown-fuse indicator or stiker Model with no indicator light Model with no indicator light screw-on rail mounting Poles Ref. Cat. Ref. Cat. Nb Mod N T8 CCN N7 CCNR X7 CC B7 CCR +N A CCN E799 CCNR G58 CC P8 CCR J55 CC C87 CCR +N N CCN S95 CCNR 8 Multi-pole assembly accessories Nb. of CC8x and CC0x8 CCx5 CCx58 Poles Ref. Cat. Ref. Cat. Ref. Cat. E0077 CC80ROASS C0 CCROASS P7 CCROASS 0* W05 CC80ROASS V9 CCROASS P7 CCROASS 0* D088 CC80ROASS Y8 CCROASS C79 CCROASS 0* Adapter for symmetrical A08 ADAP-RSCC80 F7700 ADAPCC F7700 ADAPCC 0* rail Dimensions D088 Mounting on symmetrical DIN rail with adapter. Wiring cross sections - CC8/CC0; x0 mm - CC; x5 mm - CC; x mm Screw-on mounting in back of panel Neutral tubes are systematically built in Weight of a single-pole model - 8x ; 5 g - 0x8 ; 8 g - x5 ; 0 g - x58 ; g A B C D E F G H I J K L M N CC8/ ,5 77,5 00 7,5-77,5 0,5 - CC. 5,5 CC. 7 7, , ,5 9 5, , 5, /0 FG8

8 CC, CCR CC 8x fuse holder Ith max. 5A - Un 00V for 8x fuses, with or without blown-fuse indicator For Ferrule-type Fuses Ø 8-0 Nb. of Model with no indicator light Poles Ref. Cat. Nb Mod N Z5 CCR80N C0079 CCR8 +N A870 CCR8N V7 CCR8 W7 CCR8 CC 0x8 fuse holder Ith max. A - Un 0V for 0x8 fuses, with or without indicator or striker Nb. of Model with no indicator light Poles Ref. Cat. Nb Mod N Z5 CCR80N N8 CCR0 +N H555 CCRNM X7 CCR0 Y7 CCR0 0 79,5 8 Direct mounting on symmetrical DIN rail Wire cross sections: x 0mm. Compact footprint. Insulated to IP 0 standard Single-pole weight - 8x ; 58g - 0x8 ; g Neutral tubes are systematically built in 7 8 7,5 With the indicator light a blown fuse can be quickly located if power is still on Assembly accessory Accessories Ref. Cat. CCR multi-pole assembly kit Z75 CMS80PAK * * per bag FG8 /0

9 MSC 8, MSC 0, USM, USCC For Ferrule-type Fuses Ø 8 with or without blown-fuse indicator MSC 8 fuse holder Ith max. 5A - Un 00V Model without blown fuse Model with blown fuse Poles indicator light indicator light Nb Mod Ref. Numbrer Cat. Ref. Numbrer Cat. N Q85 MSC80N T95 MSC8 F MSC8I +N B09 MSC8N R0 MSC8 W0 MSC8 +N C8 MSC8N Q8 MSC8 MSC 8 fuse holder Phase + Neutral ( mod.) Ith max. 5A - Un 00V Nb. of Model without blown fuse indicator light Poles Ref. Numbrer Cat. Numbrer Nb Mod +N F0077 MSC8NM +N J5 MSC8NM Assembly accessories Ref. Numbrer Cat. Numbrer -pole pin G55 MSCMSDMAASS 0* -pole pin Q5 MSCMSDMAASS 0* -pole pin A7 MSCMSDMAASS 0* * 0 per bag /0 FG8

10 MSC 8, MSC 0, USM, USCC For Ferrule-type Fuses Ø 0 with or without blown-fuse indicator or striker MSC 0 fuse holder no accessories Ith max. A - Un V Nb. of Model without blown fuse Model with blown fuse Poles indicator light indicator light Ref.number Cat. Ref. Cat. Nb Mod N Q85 MSC80N Q7 MSC0 W978 MSC0I +N C085 MSC0N D0 MSC0NI E MSC0 K55 MSC0I M559 MSC0 R MSC0I +N E79 MSC0N E0 MSC0NI F875 MSC0 MSC 0 fuse holder Phase + Neutral ( mod.) Ith max. A - Un V Nb. of Model without blown fuse Model with blown fuse Poles indicator light indicator light Ref.number Cat. Ref. Cat. Nb Mod +N Y07 MSC0NM C0 MSC0NMI +N S87 MSC0NM S MSC0NMI Assembly accessories Ref. Numbrer Cat. Numbrer -pole pin G55 MSCMSDMAASS 0* -pole pin Q5 MSCMSDMAASS 0* -pole pin A7 MSCMSDMAASS 0* Dimensions 78 5,5 59,5 5 7,5, ,5 70 Direct mounting on symmetrical DIN rail Indicator light (0/V)* Wiring cross sections: - single-pole: x mm - single-pole + neutral: x 0 mm Insulated to IP 0 standard Single-pole weight - 8x ; g - 8x - Ph + NM ; g - 0x8 ; g - 0x8 - Ph + NM ; 8 g * 0 per bag * With the indicator light a blown fuse can be quickly located if power is still on FG8 /0

11 MSC 8, MSC 0, USCC, USM For Ferrule-type Fuses ClassCC or Midget USCC fuse holder Ith max. 0A - Un 00V for CC class fuses Nb. of Model without blown fuse Model with blown fuse Poles indicator light indicator light Ref.number Cat. Ref. Cat. Nb Mod N W0 USN B USCC X9 USCCI P89 USCC D7008 USCCI M75 USCC Y808 USCCI +N G08 USCCN N959 USCCIN Q79 USCC E USCCI USM 0 fuse holders Ith max. A - Un 800VAC - 000VDC for 0 x 8 Midget fuses (-/" x /") Nb. of Model without blown fuse Model with blown fuse Poles indicator light indicator light Ref.number Cat. Ref. Cat. Nb Mod N W0 USN Y9 USM L USMI N75 USM Z809 USMI C858 USM Y7 USMI +N H09 USMN P959 USMIN R79 USM F USMI Assembly accessories Ref. Numbrer Cat. Numbrer -pole pin F0 USPTH 0* -pole pin C07 USPTH 0* -pole pin P8 USPTH 0* Dimensions * 0 per bag DIMENSION mm In A B C D E F G H I J.5.7 K L * With the indicator light a blown fuse can be quickly located if power is still on Direct mounting on symmetrical DIN rail Single-pole weight USCC ; 58g USM ; g /0 FG85

12 Modulostar Highlights General charateristics MODULOSTAR Series The brand-new innovative and comprehensive "MODULOSTAR " range of Ferraz Shawmut Modular Fuseholders and Fuse disconnectors is global and designed to accommodate a multitude of fuses from around the world, including - IEC industrial Cylindrical (gg, am, gd) - UL class CC, Midget - Special protection class (UR, gr, gd) in 5 sizes : 8x, 0x8, x5, x58 and 7x0 mm. All MODULOSTAR products are manufactured in accordance with IEC 09-, IEC &, UL5 and CSA - Standards. Impulse withstand voltages : - The range is tested at respectivly Uimp= KV and 8KV according to part 8... of IEC 097- between neighboring poles, between phase and wires, between phase and microswitch. Insulation voltage rating Ui = VAC and 800VAC - The blown fuse light indicators are available for VDC to 700VDC and 0VAC to -700VAC European RoHS Directive: Modulostar product range is develop in accordance with European Directive 00/95/CE dated 7 January 00, as free of halogene (PBB, PBDE), chlorine, mercury, cadmium and lead. Environmental aspects Modulostar range is design following "ecoconception" method, with sofware tool EIME (Environmental Information & Management Explorer), which takes into account the following criteria: Water Toxicity, Water Eutrophication, Hazardous Waste Production, Raw Material Depletion, Energy Depletion, Water Depletion, Global Warming, Air Toxicity, Photochemical Ozone Creation, Air Acidification Plastic material used are UL 9 V0 to V with UL Recognized Yellow card RTI ( Relative Thermal Index) > 0 C CTI ( Comparative Tracking Index) > V Bodies are in Polyamide with 0% reinforced material Handles are in Polyamide. with 5% reinforced material or in Thermodur BMC Homologations: CB report according IEC 09- and IEC 097- standards UL CSA Listed (00V AC) for class CC products ranges, UL CSA recognition ( 800V AC - 000V DC) for Midget and IEC products Vibration withstand: Tests with sine vibrations carried out at ambiant temperature with scanning each of the three main axis of the holder. Spectrum: st segment ( to Hz) constant displacement x=5mm peak nd segment ( to Hz) constant acceleration γ= 5g peak Exponential scanning speed: octave per minute. Duration : hours per axis. Climatic usage conditions: Modulostar is designed for temperate climates. For more severe climates we recommend the following: Maximum temperature 0 C 0 C 0 C C Maximum relative humidity 95% % 80% % Curent derating FG8 /0

13 Modulostar Highlights Fuse Overview Fuse ranges used in Ferraz Shawmut fusegear Class Size 0. x 8 / CC x 5 x 58 7 x 0 00V Class J Time delay AJT to 0A AJT to 0A 00V Class J Fast acting AJ to 0A AJ to 0A 00V Midget fast acting JX, ATM, SBS 0.5 to 0A 00V Class CC Time delay ATDR, ATQR, ATMR / to 0A 00V Class RK5 Time delay TR to 0A V Class RK Fast acting AK to 0A V Class K-5 OT, OTN to 0A V Class RK Time delay AD, to 0A 0V Midget Time delay ATQ 0. to 0A V-00V Midget OTM, TRM, A5Z- 0. to 0A 5V Midget Fast acting GGU, GFN to 0A 00V 5 to A 0V to A 0V 00 to 5A am 0V 0. to 0A V 0.5 to 0A V to 80A V 0. to or0a* 00V A 00V A 00V 5A gg 0V 0.5 to 5A 0V to 0A 0V 00A V 0.5 to or 0A* V to A V to 80A 0gD 00V 0 to 0A 00V 5 to 0A 00V 5 to 00A 00V to A 00V A 00V 5A V to 0A* gg with striker 0V to 0A 0V 80 to 00A V to A* V to 80A* am with striker 00V to A 0V to 5A 0V to 00A V to 0A* V 0 to 0A* V to 80A* UR 00V 0. to 0.8 V to A V 5 to 00A gr V to A V to A V 5 to 00A UR with striker 0V to 0A V to A V 5 to 00A V to V 000V to 70A gr with striker V to A V 5 to 00A 800V 8 to 0A I n maxi A A 5A 70A * development in progress /0 FG87

14 Modulostar CMS8 - CMS0 - US0 Electrical characteristics IEC fuse holders: CMS8 Nominal Voltage Ui AC/DC Voltage Isolation Uimp Nominal Current Max. power losses in the fuse links Fuse links rating Maxi RMS* Current for,, and +N poles with FS fuse links For, 5 and poles x by 0.9 For 7, 8, 9 poles x 0.8 For 0 poles x by 0,7 gg am gf / gg Cable wire section (mm ) recommanded 0V AC0B kv 5 A.5 W * Datas for ambiante temperature = 0 C. Wire range : Rigid wire = - mm (8 - AWG) Multistrand wire = 0,75-0 mm (8-8 AWG) Ferraz Shawmut recommands to use screwdrivers PZ or Flat 5.5 x mm (maximum diameter mm) Maximum Tightening Torque :.5 Nm (lb-in) IR for fuses : V MODULOSTAR Fuse holders for 8 x fuse links Pole Catalog MODULOSTAR Fuse holder without fuse light melting indicator Ref Mod. (7.5 mm) box of CMS80N CMS8 CMS8N CMS8 CMS8 CMS8N CMS8 D00 X000 Y00 Z00 A00 B00 C005 MODULOSTAR CMS8/0 NEUTRE MODULOSTAR CMS8 P MODULOSTAR CMS8 P+N MODULOSTAR CMS8 P MODULOSTAR CMS8 P MODULOSTAR CMS8 P+N MODULOSTAR CMS8 P Pole Catalog MODULOSTAR Fuse holder with fuse light melting indicator Ref Mod. (7.5 mm) box of CMS8I CMS8NI CMS8I CMS8I CMS8NI CMS8I E007 F008 G009 H00 J0 K0 MODULOSTAR CMS8 P C/I MODULOSTAR CMS8 P+N C/I MODULOSTAR CMS8 P C/I MODULOSTAR CMS8 P C/I MODULOSTAR CMS8 P+N C/I MODULOSTAR CMS8 P C/I Accessories Catalog references Mod. (7.5 mm) Maxi. RMS current (A) of poles Kit for Multi-Phase connection links Lock Tag and lockout jumping bars phase size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * phase lateral incoming power supply & phases lateral incoming power supply phase axial incoming power supply & phases axial incoming power supply CMS80PAK LOCK TAGLOCKCMS80 CMS80BBF CMS80BBF CMS80BBF CMS80BBF TBBC TBBC TBBA TBBA Z75 M55 A577 T00 V007 W008 X009 E0 G08 D05 F Note *: It is possible to use a rigid cable mm with a jumping bar.5 mm thick. FG88 /0

15 Modulostar CMS8 - CMS0 - US0 IEC fuse holders: CMS0 Electrical characteristics Nominal Voltage Ui AC/DC Voltage Isolation Uimp Nominal Current Max. power losses in the fuse links Fuse links rating Maxi RMS* Current for,, and +N poles with FS fuse links For, 5 and poles x by 0.9 For 7, 8, 9 poles x 0.8 For 0 poles x by 0,7 gg am URD / grb JX Cable wire section (mm ) recommanded V AC AC0B kv A W * Datas for ambiante temperature = 0 C. Wire range : Rigid wire = - mm (8 - AWG) Multistrand wire = 0,75-0 mm (8-8 AWG) Ferraz Shawmut recommands to use screwdrivers PZ or Flat 5.5 x mm (maximum diameter mm) Maximum Tightening Torque :.5 Nm (lb-in) IR for fuses : 0V - V MODULOSTAR Fuse holders for 0 x 8 fuse links Pole Catalog CMS80N CMS0 CMS0N CMS0 CMS0 CMS0N CMS0 MODULOSTAR Fuse holder without fuse light melting indicator Ref D00 T00 V0 W0 X0 Y0 Z05 MODULOSTAR CMS8/0 NEUTRE MODULOSTAR CMS0 P MODULOSTAR CMS0 P+N MODULOSTAR CMS0 P MODULOSTAR CMS0 P MODULOSTAR CMS0 P+N MODULOSTAR CMS0 P Mod. (7.5 mm) box of Pole Catalog MODULOSTAR Fuse holder with fuse light melting indicator Ref Mod. (7.5 mm) box of CMS0I CMS0NI CMS0I CMS0I CMS0NI CMS0 A0 B07 C08 D09 E00 F0 MODULOSTAR CMS0 P C/I MODULOSTAR CMS0 P+N C/I MODULOSTAR CMS0 P C/I MODULOSTAR CMS0 P C/I MODULOSTAR CMS0 P+N C/I MODULOSTAR CMS0 P C/I Accessories Catalog references Mod. (7.5 mm) Maxi. RMS current (A) of poles Kit for Multi-Phase connection links Lock Tag and lockout jumping bars phase size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * phase lateral incoming power supply & phases lateral incoming power supply phase axial incoming power supply & phases axial incoming power supply CMS80PAK LOCK TAGLOCKCMS80 CMS80BBF CMS80BBF CMS80BBF CMS80BBF TBBC TBBC TBBA TBBA Z75 M55 A577 T00 V007 W008 X009 E0 G08 D05 F Note *: It is possible to use a rigid cable mm with a jumping bar.5 mm thick. /0 FG89

16 Modulostar CMS8 - CMS0 - US0 IEC fuse holders: US0 Electrical characteristics Nominal Voltage Ui AC/DC V AC AC0B Voltage Isolation Uimp Nominal Current Max. power losses in the fuse links kv 0 A W Fuse links rating Maxi RMS* Current for,, and +N poles with FS fuse links For, 5 and poles x by 0.9 For 7, 8, 9 poles x 0.8 For 0 poles x by 0,7 JX URD / grb ATM, SBS, GNF, GGU ATQ, OTM, TMR Cable wire section (mm ) recommanded.5.5 Note: UL recognized Voltage are 800V AC and 000V DC * Datas for ambiante temperature = 0 C. Wire range : Rigid wire = - mm (8 - AWG) Multistrand wire = 0,75-0 mm (8-8 AWG) Ferraz Shawmut recommands to use screwdrivers PZ or Flat 5.5 x mm (maximum diameter mm) Maximum Tightening Torque :.5 Nm (lb-in) IR for fuses : 0V IEC - V IEC V UL MODULOSTAR Fuse holders for Midget and 0 x 8 fuse links MODULOSTAR Fuse holder without fuse light melting indicator Catalog Pole Ref US0N US0 US0N US0 US0 US0N US0 H05 B0 C05 D05 E05 F05 G055 MODULOSTAR US0 NEUTRE MODULOSTAR US0 P MODULOSTAR US0 P+N MODULOSTAR US0 P MODULOSTAR US0 P MODULOSTAR US0 P+N MODULOSTAR US0 P Mod. (7.5 mm) box of Pole Catalog MODULOSTAR Fuse holder with fuse light melting indicator Ref Mod. (7.5 mm) box of US0I US0NI US0I US0I US0NI US0I J057 K058 L059 M00 N0 P0 MODULOSTAR US0 P C/I MODULOSTAR US0 P+N C/I MODULOSTAR US0 P C/I MODULOSTAR US0 P C/I MODULOSTAR US0 P+N C/I MODULOSTAR US0 P C/I Accessories Kit for Multi-Phase connection links Lock Tag and lockout jumping bars phase size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * phase lateral incoming power supply & phases lateral incoming power supply phase axial incoming power supply & phases axial incoming power supply Catalog US80PAK LOCK TAGLOCKUS80 US80BBF US80BBF US80BBF US80BBF TBBC TBBC TBBA TBBA references Z75 M55 A577 T00 V007 W008 X009 E0 G08 D05 F07 Mod. (7.5 mm) Maxi. RMS current (A) of poles Note *: It is possible to use a rigid cable mm with a jumping bar.5 mm thick. FG /0

17 Modulostar CMS8 - CMS0 - US0 CMS8 & 0, US0 Dimensions Accessories Kit for Multi-Phase connection links Lock Tag and lockout jumping bars phase size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * phase lateral incoming power supply & phases lateral incoming power supply phase axial incoming power supply & phases axial incoming power supply Catalog CMS80PAK LOCK TAGLOCKCMS80 CMS80BBF CMS80BBF CMS80BBF CMS80BBF TBBC TBBC TBBA TBBA references Z75 M55 A577 T00 V007 W008 X009 E0 G08 D05 F07 Mod. (7.5 mm) Maxi. RMS current (A) of poles Note *: It is possible to use a rigid cable mm with a jumping bar.5 mm thick. /0 FG9

18 New USCC (UltraSafe) Electrical characteristics UL fuse holders: USCC Nominal Voltage Ui AC/DC Voltage Isolation Uimp Nominal Current 00V AC kv 0 A W Note: UL Listed 00V AC * Datas for ambiante temperature = 0 C. Max. power losses in the fuse links Fuse links rating Maxi RMS* Current for,, and +N poles with FS fuse links For, 5 and poles x by 0.9 For 7, 8, 9 poles x 0.8 For 0 poles x by 0,7 ATDR ATM ATMR Cable wire section (mm ) recommanded.5 Wire range : Rigid wire = - mm (8 - AWG) Multistrand wire = 0,75-0 mm (8-8 AWG) Ferraz Shawmut recommands to use screwdrivers PZ or Flat 5.5 x mm (maximum diameter mm) Maximum Tightening Torque :.5 Nm (lb-in) IR with UL Class CC fuse links : 00V ULTRASAFE Fuse holders for Class CC fuse links Pole Catalog ULTRASAFE TM Fuse holder without fuse light melting indicator Ref Mod. (7.5 mm) box of USCC USCC USCC USCC USCCN USCCN H0 K05 L0 N08 J0 M07 ULTRASAFE TM CC P ULTRASAFE TM CC P ULTRASAFE TM CC P ULTRASAFE TM CC P ULTRASAFE TM CC P+N ULTRASAFE TM CC P+N Pole Catalog ULTRASAFE TM Fuse holder with fuse light melting indicator Ref Mod. (7.5 mm) box of USCCI USCCI USCCI USCCI USCCNI USCCNI P09 R0 S0 V0 Q00 T0 ULTRASAFE TM CC P C/I ULTRASAFE TM CC P C/I ULTRASAFE TM CC P C/I ULTRASAFE TM CC P C/I ULTRASAFE TM CC P+N C/I ULTRASAFE TM CC P+N C/I Accessories Catalog references Mod. (7.5 mm) Maxi. RMS current (A) of poles Kit for Multi-Phase connection links Lock Tag and lockout jumping bars phase size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * phase lateral incoming power supply & phases lateral incoming power supply phase axial incoming power supply & phases axial incoming power supply CMS80PAK LOCK TAGLOCKCMS80 CMS80BBF CMS80BBF CMS80BBF CMS80BBF TBBC TBBC TBBA TBBA Z75 M55 A577 T00 V007 W008 X009 E0 G08 D05 F Note *: It is possible to use a rigid cable mm with a jumping bar.5 mm thick. FG9 /0

19 New USCC (UltraSafe) UL fuse holders: USCC Dimensions Accessories Kit for Multi-Phase connection links Lock Tag and lockout jumping bars phase size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * jumping bars phases size 8/0 * phase lateral incoming power supply & phases lateral incoming power supply phase axial incoming power supply & phases axial incoming power supply Catalog CMS80PAK LOCK TAGLOCKCMS80 CMS80BBF CMS80BBF CMS80BBF CMS80BBF TBBC TBBC TBBA TBBA references Z75 M55 A577 T00 V007 W008 X009 E0 G08 D05 F07 Mod. (7.5 mm) Maxi. RMS current (A) of poles Note *: It is possible to use a rigid cable mm with a jumping bar.5 mm thick. /0 FG9

20 Modulostar USFM0, UltraSafe TM USFMM Nominal Voltage Ui AC/DC V IEC 00V UL AC0B Three poles fuse holders and fuse disconnectors: USFM0 / USFMM Electrical characteristics Voltage Isolation Uimp Nominal Current Max. power losses in the fuse links kv A W Fuse links rating JX ATM, SBS, GNF, GGU 0 5 ATQ, OTM, TMR URD / grb 9 5 Cable wire section (mm ) recommanded * Datas for ambiante temperature = 0 C. Wire range : Rigid and Multistrand wire = - mm (8-0 AWG) - Mulistrand wire mm (9 AWG) with strands repartition between each part of scew - Maximum multistrand wire for each open lug =. mm ( AWG) Maximum Tightening Torque :.5 Nm ( lb-in) Ferraz Shawmut recommands to use screwdrivers PZ or Flat 5.5 x 0.8 mm (maximum diameter mm) IR with fuses : 0V IEC - V IEC V UL MODULOSTAR USFM0 for IEC 0x8 fuse links Pole / Width poles system / 5 mm width Catalog USFM0 USFM0M USFM0I USFM0MI Maxi RMS* Current for Three poles system with FS fuse links. For to 7 Three poles systems x by 0.9 MODULOSTAR USFM Fuse holder and Fuse disconnector Ref S075 T07 W078 V077 USFM0 FUSE HOL P V A EU USFM0M FUSEHOL+MCPVA EU USFM0I FUS.HOLP+V VA EU USFM0MI FUS.HOLP+MC+VV EU Pack: piece Fuse holder is without Prebreaking Microswitch (see accessories) Fuse disconnector is with mounted Prebreaking Microswitch ULTRASAFE USFMM for Midget and IEC 0x8 fuse links Pole / Width poles system / 5 mm width Catalog USFMM USFMMM USFMMI USFMMMI Ref D0775 E077 G0778 F0777 ULTRASAFE TM USFM Fuse holder and Fuse disconnector USFMM P 00V 0A UL USFMMM P 00V 0A +MS UL USFMMI P 00V 0A +LIGHT UL USFMMMI P 00V 0A +LI+MS UL Pack: piece Fuse holder is without Prebreaking Microswitch (see accessories) Fuse disconnector is with mounted Prebreaking Microswitch Fonction Fuse Fuse holder disconnector w/o Indicator w/o Indicator with Indicator with Indicator Fonction Fuse Fuse holder disconnector w/o Indicator w/o Indicator with Indicator with Indicator Accessories Lock Microswitch Additional Neutral jumping bars phases Lateral incoming power supply Axial incoming power supply Interconnexion with SEI 0A Contactor Interconnexion with Rockwell 0A Contactor Interconnexion with SIEMENS 0A Contactor Interconnexion with ABB 0A Contactor Interconnexion with GE 0A Contactor Catalog LOCK USFMAC TBBC TBBA references M55 C0797 G08 F07 of systems interconnected Maxi. RMS current (A) of poles FG9 /0

21 Modulostar USFM0, UltraSafe TM USFMM USFM 0 - USFMM Dimensions Accessories Lock Microswitch Additional Neutral jumping bars phases Lateral incoming power supply Axial incoming power supply Interconnexion with SEI 0A Contactor Interconnexion with Rockwell 0A Contactor Interconnexion with SIEMENS 0A Contactor Interconnexion with ABB 0A Contactor Interconnexion with GE 0A Contactor Catalog LOCK USFMAC TBBC TBBA references M55 C0797 G08 F07 of systems interconnected Maxi. RMS current (A) of poles /0 FG95

22 Modulostar USFM0, UltraSafe TM USFMM USFM0, USFMM Ferraz Shawmut Fuse usable in USFM* for Motors protection P. Motor Motor Ie Voltage Motor AM CC GD JTD IEC fuse links UL listed UL recognized UL Listed 0A 00/5V 9A am 0.0* CC 5* 0 gd. AJT7.5 kw 0V 7A am 0.8* CC * 0 gd.0 AJT5 V 5A 9 am 0.,* AJT0 00/5V am 0.* CC 0* 0 gd.8 AJT0 5.5 kw 0V 0 am 0.* CC 7* 0 gd.5 AJT7.5 V 7 9 am 0.8* AJT5 00/5V am 0.0* CC 5* 0 gd.5 AJT5 7.5 kw 0V am 0.* CC 5* 0 gd.0 AJT0 V 9 9 am 0.0* AJT7.5 kw 00/5V am 0.5* 0 gd.0 AJT0 kw 0V 0 am 0.5* CC 0* 0 gd.8 AJT5 0 kw V 9 am AJT0 00/5V 0 0 am gd.5 AJT0 5 kw 0V 5 am gd.0 AJT5 V 8 9 am AJT0 8 kw 00/5V 7 am gd.55 to 0V 0 am gd.5 AJT0 0 kw V 9 am AJT5 kw 00/5V am gd kw 0V 8 am gd. --- kw V 5 9 am AJT5 8 kw 00/5V 5 am gd kw 0V 7 am gd kw V 0 9 am AJT0 kw 00/5V 0 am gd kw 0V 55 am gd kw V 9 am AJT0 0 kw 00/5V 7 am gd kw 0V 7 am kw V 9 am kw 00/5V 85 am kw 0V 80 am kw V 9 9 am * Respectively in USFM0-USFCC FG9 /0

23 USFMCC (UltraSafe TM ) Electrical characteristics UL three poles fuse holders: USFMCC Nominal Voltage Ui AC/DC Voltage Isolation Uimp Nominal Current Max. power losses in the fuse links Fuse links rating Maxi RMS* Current for USFM with FS fuse links For to 7 USFM x by 0.9 ATDR ATM ATMR Cable wire section (mm ) recommanded 00V AC 8 kv 0 A W * Datas for ambiante temperature = 0 C. Wire range : Rigid and Multistrand wire = - mm (8-0 AWG) - Mulistrand wire mm (9 AWG) with strands repartition between each part of scew - Maximum multistrand wire for each open lug =. mm ( AWG) Maximum Tightening Torque :.5 Nm ( lb-in) Ferraz Shawmut recommands to use screwdrivers PZ or Flat 5.5 x 0.8 mm (maximum diameter mm) IR with UL Class CC fuse links : 00V ULTRASAFE TM USFMCC for Class CC fuse links Pole / Width poles system / 5 mm width Catalog USFMCC USFMCCM USFMCCI USFMCCMI Ref P07 B079 Q07 R07 ULTRASAFE TM USFM Fuse holder and Fuse disconnector USFMCC POLES 00V 0A UL USFMCCM POLES 00V 0A+M UL USFMCCI POLES 00V 0A LIGHT USFMCCMI POLES 00V 0A LI+MC Pack: piece Fuse holder is without Prebreaking Microswitch (see accessories) Fuse disconnector is with mounted Prebreaking Microswitch Fonction Fuse Fuse holder disconnector w/o Indicator w/o Indicator with Indicator with Indicator Accessories Lock Microswitch jumping bars phases Lateral incoming power supply Axial incoming power supply Interconnexion with SEI 0A Contactor Interconnexion with Rockwell 0A Contactor Interconnexion with SIEMENS 0A Contactor Interconnexion with ABB 0A Contactor Interconnexion with GE 0A Contactor Catalog LOCK USFMAC TBBC TBBA references M55 C0797 G08 F07 of systems interconnected Maxi. RMS current (A) of poles FG98 /0

24 USFMCC (UltraSafe TM ) USFMCC Dimensions Accessories Lock Microswitch Additional Neutral jumping bars phases Lateral incoming power supply Axial incoming power supply Interconnexion with SEI 0A Contactor Interconnexion with Rockwell 0A Contactor Interconnexion with SIEMENS 0A Contactor Interconnexion with ABB 0A Contactor Interconnexion with GE 0A Contactor Catalog LOCK USFMAC TBBC TBBA references M55 C0797 G08 F07 of systems interconnected Maxi. RMS current (A) of poles /0 FG99

25 USFMCC (UltraSafe TM ) USFMCC Ferraz Shawmut Fuse usable in USFM* for Motors protection P. Motor Motor Ie Voltage Motor AM CC GD JTD IEC fuse links UL listed UL recognized UL Listed 0A 00/5V 9A am 0.0* CC 5* 0 gd. AJT7.5 kw 0V 7A am 0.8* CC * 0 gd.0 AJT5 V 5A 9 am 0.,* AJT0 00/5V am 0.* CC 0* 0 gd.8 AJT0 5.5 kw 0V 0 am 0.* CC 7* 0 gd.5 AJT7.5 V 7 9 am 0.8* AJT5 00/5V am 0.0* CC 5* 0 gd.5 AJT5 7.5 kw 0V am 0.* CC 5* 0 gd.0 AJT0 V 9 9 am 0.0* AJT7.5 kw 00/5V am 0.5* 0 gd.0 AJT0 kw 0V 0 am 0.5* CC 0* 0 gd.8 AJT5 0 kw V 9 am AJT0 00/5V 0 0 am gd.5 AJT0 5 kw 0V 5 am gd.0 AJT5 V 8 9 am AJT0 8 kw 00/5V 7 am gd.55 to 0V 0 am gd.5 AJT0 0 kw V 9 am AJT5 kw 00/5V am gd kw 0V 8 am gd. --- kw V 5 9 am AJT5 8 kw 00/5V 5 am gd kw 0V 7 am gd kw V 0 9 am AJT0 kw 00/5V 0 am gd kw 0V 55 am gd kw V 9 am AJT0 0 kw 00/5V 7 am gd kw 0V 7 am kw V 9 am kw 00/5V 85 am kw 0V 80 am kw V 9 9 am * Respectively in USFM0-USFCC FG00 /0

26 Modulostar CMS, CMS Electrical characteristics Rated insulation voltage Ui AC/DC V AC 0 B Rated impulse withstand voltage Uimp Rated current Max. power dissipation per fuse 8 kv A 5 W Fuse rating * Values shown for 0 C ambient temperature CMS fuse holders for x5 fuses with no striker or with indicator light Poles N + N + N Cat.Num CMSN CMS CMSN CMS CMS CMSN CMS IEC fuse holders: CMS IEC fuse disconnectors: CMS gg am URD - URC URGA URGB grb glb Wiring: Rigid wire =.5-5 mm ( - AWG) - Multistrand wire: Maximum 5 mm ( AWG) Tightening torque:.5 Nm max / 0 lbs.in Ferraz Shawmut recommands to use screwdrivers PZ or Flat 5.5 x mm (maximum diameter mm). Fuse holders without indicator light Ref.Num N8 F9 E0 J05 J09 L8 G Maximum current in use for,, et +N poles with FS-fuses. for, 5 and poles, multiply by 0.8 for 7, 8, 9 x 0.7 and for 0 x 0. Mod. (7.5 mm) box of Poles + N + N CMSI CMSNI CMSI CMSI CMSNI Fuse holders without indicator light Cat.Num Ref.Num M00778 M08 C579 Z D7 Mod. (7.5 mm).5.5 Recommended wire cross-section (mm ) box of Auxiliary microswitch kit M87 Enlargement pin for auxiliary microswitch - F9 Auxiliary microswitch assembly pin J8 for x5 fuses with striker Standard ready for accessories Mod. Possible Functions Pole Ref.Num Cat.Num (7.5 mm) box of L5 CMSAC.5 Indicator light & blown fuse only CMS fuse disconnectors for all types of x5 fuses Pole Model without indicator Model with indicator light Model fitted with light ready for accessories ready for auxiliary microswitch auxiliary microswitch Cat.Num Ref.Num Ref.Num Cat.Num Cat.Num Ref.Num N N8.5 CMSP P7708 CMSM K5 CMSMI N N P9 * CMSP G99 CMSM R557 CMSMI K057 consult us CMSP N00779 CMSM T55 CMSMI D580.5 * CMSM Y8 CMSMI K N CMSNP F0 CMSNM L799 CMSNMI A * Two auxiliary microswitches (see instructions for mounting) The auxiliary microswitch function requires use of fuses with strikers. Accessories Auxiliary microswitch kit pole CMS Auxiliary microswitch kit poles CMS auxiliary microswitch kit poles CMS Auxiliary microswitch assembly pin (between kits) Enlargement pin for auxiliary microswitch Multi-pole assembly kit Indicator light kit Lock FG0 CMSW CMSW CMSW CMSPTH CMSBP CMSPAK CMSLHI LOCK * 0 per bag Model fitted with auxiliary microswitch & indicator light Cat.Num Ref.Num Cat.Num References M87 C9 D979 J8 F9 Z8 A55 M55 Mod. (7.5 mm) Mod. (7.5 mm) box of 0* 0* 0* /0

27 Modulostar CMS, CMS IEC fuse holders: CMS IEC fuse disconnectors: CMS Electrical characteristics Rated insulation voltage Ui AC/DC V AC 0 B CMS fuse holders for x58 fuses with no striker or with indicator light Poles N + N + N Accessories /0 Rated impulse withstand voltage Uimp Cat.Num CMSN CMS CMSN CMS CMS CMSN CMS Rated current Max. power dissipation per fuse 8 kv 5 A 9.5 W Fuse holders without indicator light Ref.Num M9 E8 L V5 Z8 Q7709 N87 Mod. (7.5 mm) Fuse rating box of gg am URD - URC URGA URGB grb glb * Values shown for 0 C ambient temperature. Wiring: Rigid wire =.5 - mm ( - AWG) - Multistrand wire: Maximum 5 mm ( AWG). Tightening torque: max..5 Nm - 5 lbs.in Ferraz Shawmut recommands to use screwdrivers PZ or Flat.5 x. mm (maximum diameter 7 mm). for x58 fuses with striker Pole Pole Standard ready for accessories Cat.Num Ref.Num Model without indicator light ready for accessories Cat.Num Ref.Num Mod. (7.5 mm) Model with indicator light ready for auxiliary microswitch Cat.Num Ref.Num + N + N Model fitted with auxiliary microswitch Cat.Num Ref.Num CMSNI CMSI CMSNI CMSI CMSI CMSNI CMSI FG H7 S558 Z7 M700 A8 Model fitted with auxiliary microswitch & indicator light Cat.Num Ref.Num N CMSN M9 CMSP G05 CMSM D9 A8 + N CMSNP M7 CMSMI * CMSP T559 CMSM E979 N70 consult us CMSP W57 CMSM Q70 CMSMI R770 * W57 CMSM H99 CMSMI B85 + N CMSNP A77 CMSNM P00780 CMSMI P87 8 CMSNMI 8 * Two auxiliary microswitches (see instructions for mounting) The auxiliary microswitch function requires use of fuses with strikers. box of CMSAC P088.5 Indicator light & blown fuse only CMS fuse disconnectors for all types of x58 fuses * 0 per bag Auxiliary microswitch kit pole CMS Auxiliary microswitch kit poles CMS auxiliary microswitch kit poles CMS Auxiliary microswitch assembly pin (between kits) Enlargement pin for auxiliary microswitch Multi-pole assembly kit Indicator light kit Lock Maximum current in use for,, et +N poles with FS-fuses. for, 5 and poles, multiply by 0.8 for 7, 8, 9 x 0.7 and for 0 x 0. Poles Cat.Num CMSW CMSW CMSW CMSPTH CMSBP CMSPAK CMSLHI LOCK Possible Functions References E58 L09 B J8 F9 Z8 A55 M Fuse holders without indicator light Cat.Num Ref.Num Mod. (7.5 mm) 8 Mod. (7.5 mm) Mod. (7.5 mm) box of box of 0* 0* 0* Auxiliary microswitch kit E58 Recommended wire cross-section (mm ) G05 D9 Enlargement pin for auxiliary microswitch - F9 Auxiliary microswitch assembly pin - J8

28 Modulostar CMS, CMS Mecanics for CMS & Dimensions of CMS and US products Width depending Nb poles 5 on nb. of 7.5 mm modules modules mm Dimensions of CMS and US products Width depending Nb poles 5 on nb. of 7.5 mm modules 8 0 modules mm FG0 /0

29 Modulostar CMS, CMS Mecanics for CMS & Locking system Locking reference: M55 Multipole assembly Assembly kit CMS & CMS : Z8 Assembly kit US : X797 US : F7958 Each bag of kits is sufficient for: 0 multipole assemblies 0 two-pole assemblies 5 three-pole assemblies NB: poles maximum in an assembly Mounting auxiliary microswitches four-pole assemblies Dismounting auxiliary microswitches Auxiliary microswitch functions Characteristics of the auxiliary microswitch MICRO Fuse melting: A fuse holder containing a fuse with a striker sends out a signal when the fuse element melts Min. voltage and current for operation 0VAC-DC - 00mA Rated current A AC and breaking capacity () at V A AC 0,A AC 0,A DC // M Pre-isolation: Presence: When the fuse holder opens Sends a signal when the holder is closed with no fuse in it Rated current and breaking A DC /DC capacity () at and V 5A AC A AC /DC 0,A DC () as per standard IEC 97-5 With the fuse in the handle closed state. No fuse Fuse blown Handle open /0 FG05

30 Modulostar CMS, CMS Microswitch options Mecanics for CMS & Auxiliary microswitches can only be mounted on previously prepared fuse disconnectors. Use of the auxiliary microswitch for fuse melting requires the use of fuses with strikers. auxiliary microswitch CMS (C9) - US (Z799) CMS (L09) - US (H7) or auxiliary microswitch CMS (M87+F9) CMS (E58+F9) US (Y798+F9) US (G9759+F9) auxiliary microswitches CMS (D979) - US (A7) CMS (B) - US (J79) independent auxiliary microswitches CMS ( x M87) CMS ( x E58) US ( x Y798) US ( x G7959) mechanically interconnected auxiliary microswitches CMS ( x M87+ x J8) CMS ( x E58+ x J8) US ( x Y798) + ( x J8) US ( x G7959) + ( x J8) NOTE: Do not fit with more than microswitches Supply wiring bars and terminals jumping bar for (CMS /US ) poles jumping bar for (CMS /US ) poles jumping bar for (CMS /US ) pole jumping bar for (CMS /US ) poles jumping bar for (CMS /US ) pole Single-pole terminal, side /-pole terminal, side Single-pole terminal, axial /-pole terminal, axial Cat. CMSBBF CMSBBF CMSBBF CMSBBF CMSBBF TBBC TBBC TBBA TBBA Ref. A0 Z0 Y00 C0 B0 E0 G08 D05 F07 Maximum acceptable RMS current (A) FG0 /0

31 Modulostar CMS, CMS Indicator light kit With the indicator light a blown fuse can be quickly located if power is still on Carefully remove the cover with screw drivers. Slip the indicator light s top insert into the rails, being careful not to twist the contact tabs. Put the cover back on Assembly precautions in multipole assemblies When fuse holders are side by side or very near each other (less than one module apart), they must be derated again, in addition to derating for temperature of 7.5 mm modules > 0 Derating factor None = /0 FG07

32 UltraSafe TM US, US UL fuse holders: US Electrical characteristics Rated insulation voltage Ui AC/DC Rated impulse withstand voltage Uimp Rated current Max. power dissipation per fuse Fuse rating 7 V 8 kv A,7 W * Values shown for 0 C ambient temperature. gg Maximum current in use for,, et +N poles with FS-fuses. for, 5 and poles, multiply by 0.8 for 7, 8, 9 x 0.7 and for 0 x 0. 0gD am URD - URC URGA URGB grb glb Wiring: Rigid wire =.5-5 mm ( - AWG) - Multistrand wire: Maximum 5 mm ( AWG) Tightening torque:.5 Nm max / 0 lbs.in Ferraz Shawmut recommands to use screwdrivers PZ or Flat 5.5 x mm (maximum diameter mm) Recommended wire cross-section (mm ) ULTRASAFE TM US fuse disconnectors for x5 fuses with no striker, or with indicator light or with striker X7 Pole N + N * * + N + N* * Model without indicator light ready for accessories Cat.Num Ref.Num USN US USN US US USN US S70 T7 Y75 C79 J795 Q79 Model with indicator light ready for auxiliary contact Cat.Num Ref.Num USI USNI USI USI USNI USI V7 Z7 D7 K79 R79 Model fitted with auxiliary contact Cat.Num Ref.Num USM USNM USM USM USM USM USNM USNM USM USM W7 A77 E79 G79 L797 N799 S79 V795 Model fitted with auxiliary contact & indicator light Cat.Num Ref.Num USMI USNMI USMI USMI USMI USMI USNMI USNMI USMI USMI X7 B78 F79 H79 M798 P7 T79 W79 Mod. (7.5 mm) * Two auxiliary microswitches (see instructions for mounting) The auxiliary microswitch function requires use of fuses with strikers box of Accessories Auxiliary contact kit Y798 Enlargement pin for auxiliary contact - F9 Auxiliary contact assembly pin J8 Auxiliary contact kit pole US Auxiliary contact kit poles US auxiliary contact kit poles US Auxiliary contact assembly pin (between kits) Enlargement pin for auxiliary contact Multi-pole assembly kit Indicator light kit Lock Cat.Num USMSW USMSW USMSW USPTH USBP USPAK CMSLHI LOCK References Y798 Z799 A7 J8 F9 X797 A55 M55 Mod. (7.5 mm) * 0* 0* * 0 per bag FG08 /0

33 UltraSafe TM US, US UL fuse holders: US Electrical characteristics Rated insulation voltage Ui AC/DC Rated impulse withstand voltage Uimp Rated current Max. power dissipation per fuse 7 V 8 kv 5 A 9.5 W Fuse rating / * Values shown for 0 C ambient temperature. gg Maximum current in use for,, et +N poles with FS-fuses. for, 5 and poles, multiply by 0.8 for 7, 8, 9 x 0.7 and for 0 x 0. 0gD am URD - URC URGA URGB grb glb Wiring: Rigid wire =.5 - mm ( - AWG) - Multistrand wire: Maximum 5 mm ( AWG). Tightening torque: max..5 Nm - 5 lbs.in Ferraz Shawmut recommands to use screwdrivers PZ or Flat.5 x. mm (maximum diameter 7 mm) C79 Recommended wire cross-section (mm ).5/ /0 /0 0/8 0/8 0/8 / 5/ 5/ 5/ ULTRASAFE TM US fuse disconnectors for x58 fuses with no striker, or with indicator light or with striker Pole N + N * * + N + N* * Model without indicator light ready for accessories Cat.Num Ref.Num USN US USN US US USN US B79 C79 G79 L7 S79 Z795 Model with indicator light ready for auxiliary contact Cat.Num Ref.Num USI USNI USI USI USNI USI D79 H797 M79 T797 A795 Model fitted with auxiliary contact Cat.Num Ref.Num USM USNM USM USM USM USM USNM USNM USM USM E79 J798 N79 Q79 V798 X79 B795 D795 Model fitted with auxiliary contact & indicator light Cat.Num Ref.Num USMI USNMI USMI USMI USMI USMI USNMI USNMI USMI USMI F795 K799 P79 R795 W799 Y795 C7955 E7957 Mod. (7.5 mm) * Two auxiliary microswitches (see instructions for mounting) The auxiliary microswitch function requires use of fuses with strikers box of F795 Accessories Auxiliary contact kit pole US Auxiliary contact kit poles US auxiliary contact kit poles US Auxiliary contact assembly pin (between kits) Enlargement pin for auxiliary contact Multi-pole assembly kit Indicator light kit Lock Cat.Num USMSW USMSW5 USMSW USPTH USBP USPAK CMSLHI LOCK References G7959 H7 J79 J8 F9 F7958 A55 M55 Mod. (7.5 mm) * 0* 0* * 0 per bag Auxiliary contact kit Y798 Enlargement pin for auxiliary contact - F9 Auxiliary contact assembly pin J8 /0 FG09

34 UltraSafe TM US, US Mecanics for US & Dimensions of CMS and US products Width depending Nb poles 5 on nb. of 7.5 mm modules modules mm Dimensions of CMS and US products Width depending Nb poles 5 on nb. of 7.5 mm modules 8 0 modules mm FG0 /0

35 UltraSafe TM US, US Mecanics for US & Locking system Locking reference: M55 Multipole assembly Assembly kit CMS & CMS : Z8 Assembly kit US : X797 US : F7958 Each bag of kits is sufficient for: 0 multipole assemblies 0 two-pole assemblies 5 three-pole assemblies NB: poles maximum in an assembly Mounting auxiliary microswitches four-pole assemblies Dismounting auxiliary microswitches Auxiliary microswitch functions Characteristics of the auxiliary microswitch MICRO Fuse melting: A fuse holder containing a fuse with a striker sends out a signal when the fuse element melts Min. voltage and current for operation 0VAC-DC - 00mA Rated current A AC and breaking capacity () at V A AC 0,A AC 0,A DC // M Pre-isolation: Presence: When the fuse holder opens Sends a signal when the holder is closed with no fuse in it Rated current and breaking A DC /DC capacity () at and V 5A AC A AC /DC 0,A DC () as per standard IEC 97-5 With the fuse in the handle closed state. No fuse Fuse blown Handle open /0 FG

36 UltraSafe TM US, US Microswitch options Mecanics for US & Auxiliary microswitches can only be mounted on previously prepared fuse disconnectors. Use of the auxiliary microswitch for fuse melting requires the use of fuses with strikers. auxiliary microswitch CMS (C9) - US (Z799) CMS (L09) - US (H7) or auxiliary microswitch CMS (M87+F9) CMS (E58+F9) US (Y798+F9) US (G9759+F9) auxiliary microswitches CMS (D979) - US (A7) CMS (B) - US (J79) independent auxiliary microswitches CMS ( x M87) CMS ( x E58) US ( x Y798) US ( x G7959) mechanically interconnected auxiliary microswitches CMS ( x M87+ x J8) CMS ( x E58+ x J8) US ( x Y798) + ( x J8) US ( x G7959) + ( x J8) NOTE: Do not fit with more than microswitches Supply wiring bars and terminals jumping bar for (CMS /US ) poles jumping bar for (CMS /US ) poles jumping bar for (CMS /US ) pole jumping bar for (CMS /US ) poles jumping bar for (CMS /US ) pole Single-pole terminal, side /-pole terminal, side Single-pole terminal, axial /-pole terminal, axial Cat. CMSBBF CMSBBF CMSBBF CMSBBF CMSBBF TBBC TBBC TBBA TBBA Ref. A0 Z0 Y00 C0 B0 E0 G08 D05 F07 Maximum acceptable RMS current (A) FG /0

37 UltraSafe TM US, US Indicator light kit With the indicator light a blown fuse can be quickly located if power is still on Carefully remove the cover with screw drivers. Slip the indicator light s top insert into the rails, being careful not to twist the contact tabs. Put the cover back on Assembly precautions in multipole assemblies When fuse holders are side by side or very near each other (less than one module apart), they must be derated again, in addition to derating for temperature of 7.5 mm modules > 0 Derating factor None = /0 FG

38 ST ST For Ferrule-type Fuses Ø IN ACCORDANCE WITH IEC 97- AND EN 097- OPERATION CLASS: AC0B IMPULSE WITHSTAND VOLTAGE: AND 8 kv (./ µs wave) WITH PRE-ISOLATING AND BLOWN-FUSE INDICATING MICROSWITCHES COMPLETE PROTECTION AGAINST TOUCHING OF LIVE PARTS PROTECTION DEGREE: IP X HIGH-PERFORMANCE ST RANGE COMPLIANT WITH THE NEW EUROPEAN VOLTAGE RATINGS (IEC ) U N 80- V AC/DC I N UP TO 5 A Main Characteristics Size ST AC Insulation voltage rating Ui (V) AC/DC (CEI) 700 (US) Impulse Current Fuse current Maximum fuse operating current withstand rating rating ( A ) voltage I N ( A ) I N ( A ) Uimp(kV)() gg am gr/ur URD/URC URGB/URGA grc All terminals silver-plated copper () Between close phases and phase and mass, between phases and microswitch as per IEC 97- gl Recommended copper wire gauge (mm ) Fire and fumes class NF F -0 I-F Mounting with a padlocking right side-handle for ST "D" Operation handle = 5 Operation handle with extended shaft = 5 to "FO" "FO" maxi. Designation (equipment + handle) ST IIIN FOFOD+CDELAT.D. ST IIIN FOFO+CDELAT.D. ST IIIN FOD+CDELAT.D. ST IIIN FO+CDELAT.D. ST III FOFOD+CDELAT.D. ST III FOFO+CDELAT.D. ST III FOD+CDELAT.D. ST III FO+CDELAT.D. Ref. M 09 N 09 P 095 Q 09 S 098 R 097 T 099 V 0 Qty. of «FO» Qty. of «D» Cat. FG /0

39 ST ST (for x58 fuses) "D" "FO" Unmovable screw clamp-type connections for wires: one conductor, multistrand or rigid wire: 5 mm two conductors, multistrand wire: mm two conductors, rigid wire : 5 mm Minimal section:.5 mm With tightening torque:.8 to.5 Nm Mounting: simple snap-mounting on standard symmetrical DIN-rail direct on board: two M screws with tightening torque to. Nm x Indication () Predisconnection () Poles Symbol Cat. Num Ref.Num Pck ST F08 5 & STFO M097 0 STID N STIFOD P099 0 STN D & STNFO E00 +N STND D09 55 STNFOD D057 N STN E07 & ST B & STFO R00 95 STD S00 STFOD T00 55 ST C & STFO W STD X STFOD Y STN E0 955 & STNFO A N STND B STNFOD C0 00 STD H () Reversing switch-style blown-fuse indication contacts (D model) () Reversing switch-style preisolating contacts (FO model) enabling control of protection device and opening of off load disconnector. Approvals Weight (g) Preisolating FO and blown fuse indication D switch characteristics AC insulation voltage rating (***) V V FO or D type Voltage/ current for certain operating «FO» 0 V/ ma «D» 0 V/0 ma Current rating 0 A 0 A /0 Hz * Between power circuit and microswitch terminals according to IEC 0 and 9 and NFC 00 (/0 Hz mn dry air). ** Between power circuit and microswitch terminals Uimp: impulse voltage according to IEC 97-. *** Between power circuit and microswitch terminals Mounting adapter Blue colored AF adapter (Ref. Q 0980) available for mounting on standard assymetrical DIN-rail (EN 05) and usable for all models. Supply wiring bars and terminals Interrupting rating AC voltage Inductive circuit : withstand Non-inductive current Current L/R = 5ms test 0V 0V V 0V 0V V (*) 0 A 0 A 7 A 0 A 8 A A 7.5 kv DC 5 A 0.5 A. A 0. A 7.5 kv Impulse voltage Uimp./ µs (**) 8 kv 8 kv ST er FO ème FO D open disconnector Connecting with. clips Wiring bar for x poles Size Wiring bar for x pole Size Single-pole terminal, side /-pole terminal, side Single-pole terminal, axial /-pole terminal, axial Catalog CMSBBF CMSBBF TBBC TBBC TBBA TBBA References C0 B0 E0 G08 D05 F07 Maximum acceptable RMS current (A) 5 5 /0 FG5

40 ST ST with ring pug connection Poles FO D Right Handle Designation Reference Catalog / / No ST Plage Type B B888 STRING / No ST D Plage Type B C9 STDRING / / ST II Plage Type B K087 STRING No ST II FOFOD Plage Type B L087 STFOFODRING ST II FOFOD Cde Lat. D Yes M0875 STLHFOFODRIN Plage Type B / / No ST III Plage Type B N087 STRING No ST III FOFOD Plage Type B P0877 STFOFODRING ST III FOFOD Cde Lat. D Yes Q0878 STLHFOFODRIN Plage Type B Yes ST IV FOFOD Cde Lat. D Plage Type B" M77 STLHFOFODRIN FG /0

41 Modulostar CMS7, UltraSafe TM US7 MODULOSTAR : CMS7 Fuse Disconnector ULTRASAFE TM : US7 Fuse Holder Conforms to the standards: UL 5 AND UL 80 CSA - N 9 EN 097- & (Class : AC0B) Rated insulation voltage Ui= 800VAC-DC Full protection against accidentally touching live parts. Protection degree : IP XB in accordance with the IEC standard 059. High performance, conforming to European standards (Attachment to DIN rail - Modular fuse-disconnector). The US7 models have c US approval. Electric Characteristics Insulation voltage Impulse Current Fuse Maxi fuse operating current (A) Recommended AC UI withstand voltage rating current rating 0V copper wire gauge 0gD 0V URQ-URSCC 0V-800VgRB 000V URB in V AC/DC Uimp (kv) I N (A) I N (A) URGD AWG mm 8 - WITHOUT DERATING WITHOUT DERATING WITHOUT DERATING WITHOUT DERATING WITHOUT DERATING WITHOUT DERATING (CEI) / (US) * * * Busbar and ring lug connection FG8 /0

42 Modulostar CMS7, UltraSafe TM US7 MODULOSTAR : CMS7 Fuse Disconnector ULTRASAFE TM : US7 Fuse Holder Designed for 7 x 0 mm ( /8 x / In.) ferrule fuses. (800V AC - DC, lth = A) New Improved Design Attractive design and colour Designed for all 7 x 0 ferrule fuses UR curve (class UR) gr curve (class gr) Class J (UL) The Only Fuse-Disconnector which Conforms to the Standard The only fuse-disconnector on the market that respects the pre-isolation time defined by the standard (EN097-:t >0 ms), when it is equipped with a microswitch. Ample Space for Wiring and Connection Standard wiring with a choice of either : One 5 mm cable (AWG) flexible or rigid, Two mm flexible cables (AWG), Wiring with B type connection plates for eye lugs (electronic market in the USA and Japan, global traction market). Blown Fuse Indicator The blown fuse indicator functions at between 00V and 800V AC and DC and is a standard part of the US 7 range. (Leak current less than 0.5mA) UL Approval The US 7 version has c US certification. File E57. Fire smoke resistance classification : IF in accordance with the standards NFF 0 and NFF 0 (US 7 version). The Only Fuse-Holder With IP 0 - The only fuse-holder/fuse-disconnector on the market that offers certified IP 0B (open and closed) - The only fuse-holder/fuse-disconnector on the market for this range of fuse (800V AC-DC A). Identification of Terminals The terminals are easy to identify due to the marker kit provided with the standard product. Blown Fuse Micro-Switch, Safe Pre-Isolation and fuse presence characteristics for the US7 version Rated and minimum use current : In= 5A, Imini= 00 ma Rated and minimum use voltage : Un= V, Umini= 0V Approvals : NC C NC C NO NO.8 mm connection terminals /0 FG9

43 Modulostar CMS7, UltraSafe TM US7 MODULOSTAR : CMS7 Fuse Disconnector ULTRASAFE TM : US7 Fuse Holder * Need of 5 mm distance between DIN rail and panel Versatile Methods of Mounting Option of mounting the fuse-holder with phase and neutral poles, as well as micro-switches, due to the connection accessories. Several Kinds of Attachment - With M screws, - 5 mm or 75 mm symmetric DIN rail*, - Asymmetric DIN rail with adapter (Ref. Q0980). Possibility of Using Connection Plates For a cable with a diameter greater than either a 5 mm rigid or flexible cable, or two mm flexible cables, the connection can be made using ring lug. Protection covers are provided with this series to safeguard against accidental contact. Connection to connection plates, for cables equipped with ring or fork-type lugs. Climatic Conditions of Use This range of products has been designed for use in temperate, tropical and equatorial climates, provided that the following temperature/humidity conditions are not exceeded: Maximum temperature C 0 0 Maximum relative humidity % Resistance to Vibrations Test with sinusoidal vibrations, scanning the three main axes of the holder. Spectrum : st segment (-Hz) constant displacement x = 5 mm peak nd segment (-Hz) constant acceleration γ = 5g peak Exponential scanning speed : octave per minute. Duration : hours per axis. 7x0 Fuses used Ranges U N I N Applications (, CP URGD 7.0 ) 0VAC to A Class ar - Protection of semiconductor equipment, (, CP URQ, URS 7.0 ) 0VAC to A e.g. Soft starters, static relays, or regulators. (8 CP grb ) 800VAC 8 to 0A Class gr - Protection of cables, semiconductor equipment and AC instrument circuits. (0 CP URB 7.0 ) 000VAC 5 to 70A Class ar - Protection of semiconductor equipment, e.g. Soft starters, static relays, regulators. (CC, CP glb 7.0 ) 0VDC 5 to 0A Protection of DC instrument circuits, traction auxiliary circuits, (CC, CP grb 7.0 ) 0VDC 0.8 to 5A DC fed converters. FG0 /0

IEC & 2. Fuse holders with indicator light. Poles N N M M C Z D213627

IEC & 2. Fuse holders with indicator light. Poles N N M M C Z D213627 MODULOSTAR CMS4, CMS IEC fuse holders: CMS 4 - Fuse holder compliant with IEC 09- &, and tested in accordance with IEC 0947- & for fuse disconnector usage IEC fuse disconnectors: CMS 4 - Fuse disconnectors

More information

IEC fuse holders & fuse disconnectors: CMS 14

IEC fuse holders & fuse disconnectors: CMS 14 Modulostar CMS14, CMS22 Modulostar IEC fuse holders & fuse disconnectors: CMS 14 IEC fuse holders: CMS 14: Fuse holder compliant with IEC 60269-1 & 2, and tested in accordance with IEC 60947-1 & 3 for

More information

UltraSafe US22 Modular fuse-holders

UltraSafe US22 Modular fuse-holders UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Low voltage fusegear for cylindrical fuses. Fuse Holders Fuse Disconnectors Switch Disconnectors Fused Switch Disconnectors

Low voltage fusegear for cylindrical fuses. Fuse Holders Fuse Disconnectors Switch Disconnectors Fused Switch Disconnectors Low voltage fusegear for cylindrical fuses Fuse Holders Fuse Disconnectors Switch Disconnectors Fused Switch Disconnectors FUSEGEAR FOR CYLINDRICAL FUSES Fusegear Needs and solutions IEC standard 947-

More information

Modulostar US10 Modular fuse-holders

Modulostar US10 Modular fuse-holders Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Modulostar CMS10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC

More information

American Round Fuses - Form 101 range

American Round Fuses - Form 101 range Form 0 A5QS - 50 Vac A5QS- D007J 0 A5QS- E007J 0 A5QS- F0074J 0 4 A5QS4- G0075J 0 5 A5QS5- H007J 0 A5QS- J0077J 0 7 A5QS7- K0078J 0 8 A5QS8- L0079J 0 0 A5QS0- N008J 0 A5QS- P008J 0 5 A5QS5- Q008J 0 0 A5QS0-

More information

USCC & USM UltraSafe TM Fuseholders

USCC & USM UltraSafe TM Fuseholders USCC & USM UltraSafe TM Fuseholders UltraSafe modular fuseholders for midget and class CC fuses Mersen UltraSafe Modular Fuseholders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2

More information

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6 ATDR (Class CC TD) - 600Vac/300Vdc /4 ATDR/4 W2008J /2 ATDR/2 Q223068J 8/ ATDR8/ K20397J ATDR T2727J -/8 ATDR-/8 Y28820J -/4 ATDR-/4 J2830J -4/ ATDR-4/ K29337J -/2 ATDR-/2 Y2778J -6/ ATDR-6/ K29866J -8/

More information

gg ferrule-style fuses

gg ferrule-style fuses gg 8.5 x 31.5-400V Size Current Voltage Cat. number Ref. number Cat. number Ref. number Voltage Ref. number Cat.number Pckg (A) (V) w/o indicator w/o indicator with indicator with indicator (V) with striker

More information

Fuse Blocks & Holders

Fuse Blocks & Holders ULTRASAFE Fuse olders / USCC, USM & DC ULTRASAFE Fuse olders / USFM ULTRASAFE Fuse olders / US3J & US6J ULTRASAFE Fuse olders / US14 & US22 Fuse Blocks / Class J Space-Saving Fuse Blocks / SJ Series Fuse

More information

Gears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.

Gears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No. Clip lock design for CL-14 series Cat. No. 228-700-520 Cat. No. 228-700-530 (Pair at bottom) (Single at top) The Clip Lock design provides a reliable, high-pressure contact. Ferraz Shawmut CL-14 fuses

More information

Fuse Blocks & Holders

Fuse Blocks & Holders Fuse Blocks & olders Finger-safe IEC, Traditional, Panel Mount... You name the block, we ve got it in stock. Your problem: You need a range of standard fuse blocks to meet industrial requirements. You

More information

Semiconductor Fuses Microswitches & Studs

Semiconductor Fuses Microswitches & Studs MICROSWITCH SYSTEMS ADAPTED TO THE FOLLOWING FUSES: - PSC sizes 0,,, / 70, 7, 7, 7 - Blade-type PSC (PA) sizes 0-, - / 70, 7, 7, 7 - PSC sizes 000 / 00 New MS L -5 B6 MS PA -5 HIGHLY RESISTANT STUDS OFFERING

More information

ULTRASAFE Fuse Holders The safety evolution continues.

ULTRASAFE Fuse Holders The safety evolution continues. ULTRASAFE Fuse Holders The safety evolution continues. The Revolutionary Advantages Ferraz Shawmut continues to lead the safety evolution with even more improvements to our popular ULTRASAFE fuse holders.

More information

G eneral Purpose Fuses

G eneral Purpose Fuses G eneral Purpose Fuses North American Power Fuses AMP-TRAP2000 AMP-TRAP2000 AJT Class J - Time Delay 1 to 600A - - Motor, motor controller, control transformer, and circuit back-up protection. Space saving

More information

Fusegear for Semiconductor Fuse

Fusegear for Semiconductor Fuse Fusegear for Semiconductor Fuse IP 20.SI Bases for PSC ranges: SI TT, SI 000/00, SI DIN SI TT for stud-type fuses SI 00 for bracket-type fuses STANDARD VERSION SI FUSEHOLDERS FOR STUD-TYPE FUSES, FOR BLADE-TYPE

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

fuses fuse holders CYLINDRICAL

fuses fuse holders CYLINDRICAL fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES

More information

Semiconductor Fuses European Fuses

Semiconductor Fuses European Fuses 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos

More information

onlinecomponents.com

onlinecomponents.com 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current

More information

6,3* 1,6 No Printed circuitboard Brass, Nickel plated MR 5-6 Y Yes Yes 5x20 &6x32

6,3* 1,6 No Printed circuitboard Brass, Nickel plated MR 5-6 Y Yes Yes 5x20 &6x32 x20 and 6x32 Fuse sizes CLIPS FOR PRINTED CIRCUIT BOARD OR SCREW MOUNTING RATED CURRENT BELOW 30A* DEPENDING ON TYPE Main Characteristics Rated Power End Reference in box blister Catalog Size Current acceptance

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw Modulostar Motor Branch 400V AC - 690V AC up to 11 kw Innovations in MODULOSTAR to control energy in motor starters Already active in the field of motor starters with rated current over 32A per phase,

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

CLASS J 600 Volt Fuse Blocks

CLASS J 600 Volt Fuse Blocks CLASS J 600 Volt Fuse Blocks Mersen Class J fuse blocks accommodate all Class J fuses. A choice of screw, pressure plate, box and special order stud connectors it a wide range of stranded or solid copper

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

Switches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION:

Switches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION: Fused CONTROL: Side control, padlockable in off position by three padlocks. Safe and reliable of contact position on handles. SWITCHING: Double isolation per phase. Complete isolation of fuse when circuit

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses x38 grb - 69VAC 69V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: - rated current (or rating) I N - pre-arcing I 2 t (I 2 t p ) at ms - total operating I 2 t (I 2 tt) at

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

Cylindrical fuse-link

Cylindrical fuse-link ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCBO 6000 A Phase + Neutral, neutral right side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Btdin-RS RCBO 2p Phase + Neutral, neutral on right Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES , am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator

More information

Helio Protection. Solar solutions designed by Ferraz Shawmut. Power generation & distribution.

Helio Protection.   Solar solutions designed by Ferraz Shawmut. Power generation & distribution. 1 Helio Protection Solar solutions designed by Ferraz Shawmut www.helioprotection.com Transportation Power conversion Power generation & distribution Industrial controls Power quality 2 A free, renewable

More information

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead , am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or

More information

R.C.B.O. SP / 1 module

R.C.B.O. SP / 1 module 87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...

More information

DX³ RCBO 6000A Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

FUSES 8.1. Questions? Answers at Western US: CED-ELEV

FUSES 8.1. Questions? Answers at Western US: CED-ELEV FUSES Western US: -66 CED-ELEV or visit us online at www.cedelevator.com for 24 hour order entry, cross reference data base, product specifications with pictures and much more! Full line catalog available

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

UL248 North American Low Voltage Fuses

UL248 North American Low Voltage Fuses UL248 North American Low Voltage Fuses UL198 : Old low voltage fuse standards UL standards UL248 : New old voltage fuse standards UL512 : Fuse block standards 2/ 23 They establish : UL standards The dimensional

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

CYLINDRICAL. fuse holders

CYLINDRICAL. fuse holders fuse holders CYLINDRICAL 04 07 PMC MODULAR FUSE COMPACT HOLDERS 07 -CC FOR CC CLASS FUSE-LINKS 08 PMF 09 SC SCREW FIXING 10 PMB PLUG CONNECTION 10 CLIP CONTACT FOR φ10 FUSE-LINKS 09 BAC OPEN FUSE BASES

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

IEC Low Voltage Products Module 4

IEC Low Voltage Products Module 4 IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

E 90 range of fuse disconnectors and fuseholders Uncompromising performance E 90 range of fuse disconnectors and fuseholders Uncompromising performance Designing simplicity ABB competence serving the most demanding customers Suitability for disconnection and switching, effective

More information

Gears & Fuse Gears. IEC General Purpose Fuses NH Fuses Plastic Bases 00-EP/TP. 690V Polyester fuse bases for NH fuse-links.

Gears & Fuse Gears. IEC General Purpose Fuses NH Fuses Plastic Bases 00-EP/TP. 690V Polyester fuse bases for NH fuse-links. -EP/TP NH fuse bases are designed for fuse-links with rated voltages up to 69 V and VD. They are in compliance with IE 669, DIN VDE 66, part, and DIN 6 (dimensions). NH fuse bases are available for delivery

More information

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Microswitches M series

Microswitches M series Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

FERRAZ SHAWMUT IS NOW. Fuses Fusegear

FERRAZ SHAWMUT IS NOW. Fuses Fusegear FERRAZ SHAWMUT IS NOW Fuses Fusegear FOUR KEY ASSETS TO SERVE FIVE MARKETS As the global specialist in electrical and thermal protection for electrical equipment in industry, Ferraz Shawmut serves five

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information