V8043A,E,F 5000 Series

Size: px
Start display at page:

Download "V8043A,E,F 5000 Series"

Transcription

1 PPLITION These valves consist of a motorized V80,, 5000 Series ZON VLVS actuator and valve assembly for controlling the flow of hot water to a heat exchanger such as a radiator, convector, finned baseboard radiator, or infloor radiant coil for space temperature control. The V series valves provide two-position, straight through control of supply water at up to 00 psi operating pressure. Quick it actuator provides easy snap on and off connection to the valve assembly. SPIITION ctuator lectrical ating: Vac 60 Hz, 0.0 urrent raw, 5 W, 7. V maximum lectrical onnection: 8 leads or screw terminal board uxiliary Switch ating: 0V,. running, 6. Inrush (60 Hz); 50 V Pilot duty at V. luid Temperature: Standard models (class motor): 00 (9 ) Max. mbient Temperature: 5 (5 ) Max. Humidity Limits: 95% elative Humidity, Non-condensing Shipping and Storage Temperature: -0 to 50 (-0 to 65 ). tmosphere: Non-corrosive, non explosive. Maximum Soldering Temperature: 500 (60 ). ubber ball plug must be moved away from the seat for soldering. Maximum System Pressure ating: 00 psi (000 kpa), PN0. low haracteristics: Quick opening for on-off application. Slow return for water hammer resist. Maximum lose-off ating (@ low apacity ating) : 0 psi (@.5 v) 8 psi (@ 8 v) Patent Pending ctuator Materials: ase:galvanized steel. over : zinc plated steel. Sector gear: rass Valve Material: ody of forged brass; drive shaft stem of stainless steel; ball plug of una-n rubber; o-ring seals of PM rubber. Service Medium: Suitable for glycol/water mix up to 50:50 use in closed hydronic systems. Not for use with oxygenated water, potable water or steam. Use this valve in hydronic systems which do not contain dissolved oxygen in the system water. The dissolved oxygen, which is found in systems that have a frequent source of make-up water, causes the rubber plug inside the valve to deteriorate and eventually fail. pprovals: S /US ertified to anadian Standards ssociation and Underwriter's Laboratories Standards. MOLS V80 (Straight through, Normally losed) V80: Leadwires V80: Leadwires and nd Switch : Terminal oard and nd Switch Printed in anada orm No

2 V0, V80 SWT OPP ONNTION MOLS 6 7/8 I. -/8 () (60) 8 -/ () 5 -/ (89) -/ () -/ (8) U MN OPN 5-/ () /8 (0) HIGHT N MOV OV. IMNSIONS O / IN. OPP TUING. IMNSIONS O / IN OPP TUING. IN 7 OUT IMNSIONS O IN. OPP TUING. -7/8 IN. () MX ON V80 WITH MINL O NLOSU. V0 N V80 VLVS THT NOMLLY OPN IN TH -NGIZ POSITION HV NO MNUL LV. MOUNTING INSUTIONS. OPNING O / IN. ONUIT ON MNUL LV SI O V0, V80. 5/ () -5/6 () -/8 (5) -/6 () -5/8 (66) -/ (70) -/8 (86) M075. ig. - Mounting imensions in in. (mm in rackets) UTION. isconnect power supply before connecting wiring to prevent electrical shock or equipment damage.. Normally it is not necessary to remove the actuator from the valve body during installation. If the valve must be disassembled, be certain that it is reassembled with the water flow in the direction of the arrow. eversal of the actuator results in damage to the gear. train. On V systems, never jumper the valve coil terminals even temporarily. This can burn out the heat anticipator in the thermostat. INSTLLTION When Installing this Product. ead these instructions carefully. ailure to follow them could damage the product or cause a hazardous condition.. heck the ratings given in the instructions and on the product to make sure the product is suitable for your application.. Installer must be a trained, experienced service technician.. fter installation is complete, check out product operation as provided in these instructions. Location Install the valve in an area with adequate clearance to: - Move the manual opening lever on the side of the actuator - emove the actuator cover - Wire the actuator -eplace the actuator motor The valve location should be in an area where the temperature does not exceed the maximum valve operating ambient temperature and fluid temperatuare. Manual Lever The V80 normally closed valves can be opened manually by moving the manual lever slowly and firmly to the MN. OPN position and pushing up to the stop. The stop permits the valve to be locked in the open position. The valve returns to automatic position when it is energized.

3 MOUNTING The valve can be mounted in any position on a vertical line. See ig.. If the valve is mounted horizontally; the actuator must be even with or above the center line of the piping. Make sure to leave enough room above the actuator to remove the cover for servicing. Mount the valve directly in the tube or pipe after the coil. Make sure that the flow through the valve is in the direction indicated by the arrow stamped on the valve body. HOIZONTIL PIPING thermostat or controller connected to the valve so that the valve runs through its cycle. Make sure the valve runs smoothly and positively from closed to open to closed again. (See Operation and heckout Sections.) MOV TH TU OM TH VLV OY (See ig. ) NOT! It is not necessary to drain the hydronic system if the valve body assembly remains in the pipe line.. Switch power supply O. isconnect electrical leads carefully, noting the position and colour of each lead.. Place the manual lever in the MN. OPN position.. emove actuator by fully depressing spring release button and lift it straight off of the body. VTIL PIPING M06 ig. - Mounting Positions Sweat opper Models. Use new, properly reamed pipe, free from dents or corrosion.. Place the valve on the pipe. Set the manual opening lever to MN. OPN position before applying heat. This protects the plug inside the valve by removing it from the seat.. Sweat the joints, keeping the outer surface free from solder. O NOT use silver solder because of the high melting temperature required. INSTLL OMPLT VLV (V80):. isconnect power supply before connecting wiring to prevent electrical shock or equipment damage.. Install valve into pipe on the return side of the coil. (See Mounting Section.). Make wiring connections to valve. (efer to Wiring section for proper instructions.). Inspect the valve installation to ensure that all connections and adjustments have been correctly made. djust the. PSS LOKING UTN U OPN. PL MNUL LV IN OPN POSITION. LIT TU SIGHT UP ig. - emoving ctuator from Valve ody INSTLL PLMNT TU ON TH VLV OY. lign the parallel flat surfaces in double- shaft of valve body with notch in side of body (i.e. 90 to water flow.) See ig.. This makes actuator attachment easier.. Wiring connections may be made either before or after actuator installed on valve body.. Place the manual lever on the actuator in the MN. OPN position.

4 . Line up motor coupling to the parallel flat surfaces in double- shaft of body and fit the actuator onto the valve body, ensuring that the shaft seats correctly. (See ig. 5) 5. Snap actuator onto body by pressing down. 6.The manual lever may be released manually, but it is also automatically released when the valve is operated electrically. Parallel flat surfaces align with Notch on ouble- Shaft side of valve body LIN LS MO UXILIY SWITH (TYPILLY ) IUL O NOTH VLV LS Notch M595 ig. 6 - Typical wiring for V80, V80. ig. - Shaft Position (TYPILLY ) ctuator oupling IUL O NOTH VLV Notch Tab TH TH L Notch V NSOM POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. M595 ig. 5 - Installing ctuator WIING isconnect the power supply before connecting wiring to prevent electrical shock or equipment damage. ll wiring must comply with local codes and ordinances. onnections to the individual valves are shown in ig. 6 and 7. See ig. 8 through for typical hookups. If replacing a Taco, ole, lair or White odgers -wire valve with a -wire V80 or, see ig. 5 through 7. heck that the pressure rating of the new valve is appropriate for the application. L ig. 7 - Typical wiring for. T8 T8 T8 V80 V80 V80 POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. ONNT V80 LK LWI. M068 ig. 8 - T8 Thermostat, V80 valve hookup.

5 T8 T8 T8 T8 T8 T8 L L V80 V80 V80 V80 V80 V80 L006 HIGH LIMIT OIL PIMY ONOL O NSOM N LOW VOLTG GS VLV T T UN ONOL IUIT IUL POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. ONNT V80 LWI. ONNT V80 LWIS L LIN N PIMY ONOL. M069 ig. 9 - T8, V80 zone hookup for gas or oil. No domestic hot water. IUL POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. ONNT V80 LWI. ONNT V80 LWIS QUSTT. M070 ig. 0 - T8, V80 zone hookup for gas or oil with or ithout domestic hot water. Without domestic hot water, use L88J for gas, and L88 for oil. With domestic hot water, use L8 for gas, and L8 or for oil. V0, V80 HTING VLV OP OOLING ZON ZON ZON MO LU POW JUMP H VLV QUSTT HNGOV ONOL SWITHS HTING () T LUI TMPTU O 85 (9 ) MX OOLING (LU) T LUI TMPTU O 60 (8 ) MIN. M07 TV T Z L8G L 0 V POW SUPPLY IUL UN IUIT M595 ig. - Wiring diagram for V and V8 with quastat changeover control. ig. - Typical -zone system. Use an T87 Transformer to power up to five more zone valves. 5

6 ONNTIONS O V80 (LWI MOL) ZON V80 ZON ZON ZON ZON W W775 PNL IUL ONOL IUIT ZON ZON ZON ZON INTGL NSOM POW SUPPLY L W775 PNL W W W W M5980 ig. - Typical -zone system. Use an additional W775 to power up to four more zone valves. ZON ZON ZON ZON ZON 5 UN N / O IUL IUIT V80 V80 TH- TH TH- TH TH- TH L T87 NSOM POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. NOT: I O PMITS, V80 N N US INHNGLY WHN WI S SHOWN. M06 ig. - Typical 5-zone system. Use an T87 Transformer to power up to five more zone valves. L UXILIY IUITS TO VLV L UXILIY IUITS V80 POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. M5958 POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. M06 ig. 5 - xisting Taco system. (Wires are identified with letters to correspond with wires in ig. 6 and 7.) ig. 6 - Wiring Honeywell V80 to Taco System (Wires are identified with letters to correspond with wires in ig. 5.) 6

7 L UXILIY IUITS L MINLS UN LY L UXILIY IUITS L MINLS UN LY POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. M5966 POW SUPPLY. POVI ISONNT MNS N ig.0 -. Wiring Honeywell to ole System (two options). OVLO POTTION S QUI. (Wires are identified with letters to correspond with wires in ig. 8.) M5960 ig. 7 - Wiring Honeywell to Taco System (two options). (Wires are identified with letters to correspond with wires in ig. 5.) OL VLV L LI VLV MINLS UN LY L 5 POW SUPPLY. POVI ISONNT MNS MINLS N OVLO POTTION S QUI. UN LY M5977 ig. 8 - xisting ole System. (Wires are identified with letters to correspond with wires in ig. 9 and 0.) POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. M5978 ig. - xisting lair System. (Wires are identified with letters to correspond with wires in ig. and.) L MINLS UN LY V80 L MINLS UN LY V80 POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. M5965 POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. M5965 ig. 9 - Wiring Honeywell V80 to ole System. (Wires are ig. - Wiring Honeywell to lair System. (Wires are identified with letters to correspond with wires in ig. 8.) identified with letters to correspond with wires in ig..) 7

8 L MINLS UN LY UXILIY IUITS L L MINLS UN LY POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. M5966 ig. - Wiring Honeywell to lair System (two options). (Wires are identified with lettersto correspond with wires in ig..) WHIT-OGS W VLV O UXILIY VLV IUIT UXILIY IUITS L 5 6 TH- TH POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. I NSOM SUPPLIS POW UXILIY IUIT, WI UXILIY IUIT S SHOWN IN LOW IGM. TP UNUS N N TUK IN HOL. M57 ig. 6 - Wiring Honeywell to White-odgers System (one option) L POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. M57 ig. - xisting White-odgers System. L L UXILIY IUIT L UXILIY IUIT ON UXILIY IUIT POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. I NSOM SUPPLIS POW UXILIY IUIT, WI UXILIY IUIT S SHOWN IN LOW IGM. TP UNUS N N TUK IN HOL. M57 ig. 5 - Wiring Honeywell V8 to White-odgers System. UXILIY IUIT L 5 6 POW SUPPLY. POVI ISONNT MNS N OVLO POTTION S QUI. I NSOM SUPPLIS POW UXILIY IUIT, WI UXILIY IUIT S SHOWN IN LOW IGM. TP UNUS N N TUK IN HOL. M57 ig. 7 - Wiring Honeywell to White-odgers System (alternate option). 8

9 OPTION UTION On V systems, never jumper the valve coil terminals even temporarily. This can burn out the heat anticipator in the thermostat. utomatic Operation On a call for heat by the zone thermostat, the valve opens and its auxiliary switch contacts make, closing the circuit to the system circulator. In a multizone system with all the valve auxiliary switches wired in parallel, any zone calling for heat can operate the circulator. When the call for heat ends, the valve closes by integral spring return. The auxiliary switch contacts break the circulator circuit. Manual Operation The motorized valve can be opened manually by lifting the manual opening lever over the stop and pushing slowly and firmly to the MN. OPN position. The stop permits the valve to be locked in the open position. The valve returns to automatic position when the valve is energized. Normally losed Models With the manual opener set to U and the actuator energized, the valve is opened as shown in ig. 8. When the actuator is de-energized, a spring-return mechanism drives the valve to the closed position as shown in ig. 8. The valve can also be opened with no electrical power by moving the manual opening lever over the stop and pushing slowly and firmly to the MN. OPN position. The stop permits the valve to be locked in the open position. The valve returns to the automatic position when the valve is energized. uxiliary switch is not energized when the valve is manually opened. NOT: low direction arrow is stamped on the valve body indicating flow direction from Inlet Port to Outlet Port. IN OPN POSITION OUT IN OUT LOS POSITION M595 ig. 8 - V80 operation for normally closed valve. HKOUT. aise the setpoint on the zone thermostat above the room temperature to initiate a call for heat.. Observe all control devices the valve should open and the auxiliary switch should make the circuit to the circulator or other valve at the end of the opening stroke.. Lower the setpoint on the zone thermostat to below the room temperature.. Observe the control devices. The valve should close and the auxiliary equipment should stop. SVI This valve should be serviced by a trained, experienced service technician.. If the valve is leaking, drain the system and check to see if the O-ring needs replacing.. If the gear train is damaged, replace the entire actuator assembly. See the Installation section. If the motor is burned out, replace the motor. See eplacement Parts list in the LIN atalog. NOT: Honeywell zone valves are designed and tested for silent operation in properly designed and installed systems; however, water noises can occur as a result of excessive water velocity or piping noises can occur in high temperature (higher than (00 ) systems with insufficient water pressure. Valves are designed for normal cycling operations. Product life will be shortened if energized continuously. 9

10 y using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. utomation & ontrol In anada Honeywell Honeywell Limited/Limitée 985 ouglas rive North 5 ynamic rive Golden Valley Toronto, Ontario MN MV Z9 0

V4043 and V4044 Motorized Valves

V4043 and V4044 Motorized Valves V03 and V0 Motorized Valves INSTALLATION INSTRUCTIONS FEATURES V0 These valves consist of an actuator motor and valve assembly for controlling the flow of hot or cold water. The V03 provides 2-position,

More information

V4043/V4044 Motorized Valves

V4043/V4044 Motorized Valves V4043/V4044 Motorized Valves PRODUCT SPECIFICATION SHEET FEATURES V4043 provides 2-position, straight-through control of water. V4044 provides 2-position diverting control of water. Compact construction

More information

V4043A,B,E,J; V4044A,B; V8043A,B,E,F,J; V8044A,B,E Motorized Valves

V4043A,B,E,J; V4044A,B; V8043A,B,E,F,J; V8044A,B,E Motorized Valves V0,,,J; V0,; V80,,,F,J; V80,, Motorized Valves FTURS PRODUT DT V0, V0, V80, V80 Replacement Powerhead V0, V80 The V0 and V80 provide -position, straightthrough control of water. The V0 and V80 provide

More information

VB2, VB3 Ball Valve/Actuator Assemblies

VB2, VB3 Ball Valve/Actuator Assemblies V2, V all Valve/ctuator ssemblies TURS PROUT T V2 V V2 ll Models Sizes from 1/2 in. to 2 in. with internal nominal pipe thread (NPT) connections. qual Percentage flow characteristics. ield configurable

More information

M436A/M836A,B Damper Motors

M436A/M836A,B Damper Motors M436A/M836A,B Damper Motors FEATURES INSTALLATION INSTRUCTIONS APPLICATION M436A/M836A,B Damper Motors are spring return (SR) motors used for residential and light commercial applications in Series 40

More information

VC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS

VC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES INSTALLATION INSTRUCTIONS Power consumption: 6 Watts Max. at nominal Voltage (during valve position change). Use 24 V Class 2 transformer and provide

More information

R EGI S TERED. Function

R EGI S TERED. Function Z series zone valves R EGI S TERE S EN ISO 900:000 ert. n FM 64 UNI EN ISO 900:000 ert. n 0003 LEFFI 0/09 N Replaces 0/04 N Function Z-one valves are used to automatically shut-off the flow or redirect

More information

VBF5011, VBF5013 Control Ball Valves With Flanged Connections

VBF5011, VBF5013 Control Ball Valves With Flanged Connections 0, 0 ontrol all alves With langed onnections INSTLLTION INSTRUTIONS PPLITION The 0 Two-Way and the 0 Three-Way ontrol all alve control hot and chilled water with glycol solutions up to 0% in heating, ventilating

More information

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA Motorized ball valves with -wire control 644-644 series SO 900 M 64 SO 900 No. 000 0/ N Replaces 0/07 N unction Zone valves are used to automatically shut-off the flow, redirect or modulate hot and chilled

More information

CALEFFI. zone valves. Z series 01115/14 NA. Replaces 01115/11 NA. Function

CALEFFI. zone valves. Z series 01115/14 NA. Replaces 01115/11 NA. Function Z series zone valves Function REGI STERE S EN ISO 900:000 ert. n FM 64 UNI LEFFI 0/4 N Replaces 0/ N Z-one valves are used to automatically shut-off the flow or redirect hot and chilled water in hydronic

More information

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators ML640, ML740 Non-Spring Return Electric Linear Valve Actuators EATURES Quick and easy installation. No separate linkage required. Conduit connector is standard. No adjustments required. Low power consumption.

More information

Accessories. UP timer. Timer control. Approvals. UP Series

Accessories. UP timer. Timer control. Approvals. UP Series UP timer Specifications (previous/current) Type: 24 Hr. 3-position On/Timer/Off 15-minute interval Size: 3.77 x 2.85 x 1.25" Supply voltage: 120 VC Power consumption: 1 V Switch rating: SPT Resistive:

More information

Erie VT/VS PopTop Series Two Position Spring Return Valves

Erie VT/VS PopTop Series Two Position Spring Return Valves Erie VT/VS PopTop Series Two Position Spring Return Valves General & High Close-Off PopTop Zone Valves General Instructions pplication Erie PopTop Series valve bodies and actuators provide easy installation

More information

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB Motorised ball valve for central heating systems 638 series M 21654 003 LI 01196/18 G replaces dp 01196/12 G unction Motorised ball valves allows both automatic shut-off and diversion of the thermal medium

More information

G6125C, 2-Way, Pressure Compensated Flanged Globe Valve

G6125C, 2-Way, Pressure Compensated Flanged Globe Valve G6125, 2-ay, Pressure ompensated langed Globe Valve pplication This valve is typically used in large air handling units on heating or cooling coils. This valve is suitable for use in a hydronic system

More information

F6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6125H, 5, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves Product ulletin VG000 Issue ate 11/01/01 VG000 Series High-apacity/High-loseoff Electric Zone Valves VG000 Series High-apacity/High-loseoff Electric Zone Valves are designed to regulate the flow of water

More information

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

ML6425, ML7425 Spring Return Electric Linear Valve Actuators

ML6425, ML7425 Spring Return Electric Linear Valve Actuators ML645, ML745 Spring Return Electric Linear Valve Actuators PRODUCT DATA EATURES APPLICATION The ML645 Spring Return Electric Linear Valve Actuators are floating control actuators used with controllers

More information

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6100H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions

More information

Erie VM PopTop Series Modulating Valves

Erie VM PopTop Series Modulating Valves Erie VM PopTop Series Modulating Valves Floating "T" & Proportional "P" Standard and Spring Modulating Valves General Instructions pplication The Erie Modulating PopTop Series valve actuator assemblies

More information

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators ML640, ML740 Non-Spring Return Electric Linear Valve Actuators EATURES Quick and easy installation. No separate linkage required. Conduit connector is standard. No adjustments required. Low power consumption.

More information

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators FOR FIRE/SMOKE CONTROL APPLICATIONS FEATURES PRODUCT DATA APPLICATION The MS4104, MS4109, MS4604, MS4609, MS8104 and MS8109

More information

G7150D, 3-Way, Diverting Flanged Globe Valve

G7150D, 3-Way, Diverting Flanged Globe Valve G7150D, 3-ay, Diverting Flanged Globe Valve pplication This valve is typically used in Large ir Handling Units on heating or cooling coils. This valve is suitable for use in a hydronic system with variable

More information

35 and 70 lb-in. Non-Spring Return Direct Coupled Actuators ML6161, ML7161, ML6174, ML7174

35 and 70 lb-in. Non-Spring Return Direct Coupled Actuators ML6161, ML7161, ML6174, ML7174 35 and 70 lb-in. Non-Spring Return Direct Coupled Actuators ML66, ML76, ML674, ML774 PRODUCT DATA FEATURES Selectable 45,, or 90 stroke in both clockwise (cw) or counterclockwise (ccw) directions. 0 to

More information

Q5024A,B Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS

Q5024A,B Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS Q5024A,B Globe Linkages FOR DIRECT COUPLED ACTUATORS PRODUCT DATA Heavy-duty steel rack pinion construction aluminum die-cast housing. Maintenance-free construction. Flexible actuator mounting orientation.

More information

G765, 3-Way, Mixing Flanged Globe Valve

G765, 3-Way, Mixing Flanged Globe Valve pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable flow. Suitable ctuators Non-Spring

More information

Catalog. Product Catalog. Setting a new standard for: Quality Reliability Value Global Compatibility

Catalog. Product Catalog. Setting a new standard for: Quality Reliability Value Global Compatibility atalog Product atalog Setting a new standard for: Quality Reliability Value Global ompatibility Table of ontents 3- Valves 3 irect Acting Solenoid Valves (M3V) 4-5 3-Way Solenoid Valves (M3V) 6-7 4-Way

More information

VG2000 Series Cast Iron Flanged Globe Valves

VG2000 Series Cast Iron Flanged Globe Valves Installation Instructions VG2000 Issue ate November 15, 2002 VG2000 Series ast Iron Flanged Globe Valves pplication VG2000 Series ast Iron Flanged Globe Valves are primarily designed to regulate the flow

More information

Selection Guide. Vx-7000 & Vx-9000 Series Mx4x-6xxx & Mx4x-7xxx Series. Globe Valve Assemblies. Actuator/Linkage Assemblies

Selection Guide. Vx-7000 & Vx-9000 Series Mx4x-6xxx & Mx4x-7xxx Series. Globe Valve Assemblies. Actuator/Linkage Assemblies Vx-7000 & Vx-9000 Series Mxx-6xxx & Mxx-7xxx Series Selection Guide Linked Globe Valve ssemblies ctuator/linkage ssemblies with DuraDrive ctuators Globe Valve ssemblies The V, VF, and VS-7000 and -9000

More information

G7100S, 3-Way, Mixing Flanged Globe Valve

G7100S, 3-Way, Mixing Flanged Globe Valve pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable flow. Suitable ctuators Non-Spring

More information

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators lectric, Hydraulic, and Pneumatic ctuators TL 1. Select Valve ody including P ode (Valve Size, v Rating, Port ode) or select Valve ssemly correct (refer to Tale 3 and Tale 3 also) less ctuator ode (XXX)

More information

G765, 3-Way, Mixing Flanged Globe Valve

G765, 3-Way, Mixing Flanged Globe Valve G765, 3-Way, Mixing langed Globe Valve pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable

More information

Zone Valves and Parts (Honeywell)

Zone Valves and Parts (Honeywell) 28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial

More information

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

3-Way Linked Globe Valve Assemblies with Linear Series Actuators Linked Globe Valve ssemblies with Linear Series ctuators Note: hoose a valve assembly having a close-off pressure capability sufficient for the application. Not all valve body and actuator combinations

More information

ComfortPoint Programmable Lon, VAV/Unitary Controllers

ComfortPoint Programmable Lon, VAV/Unitary Controllers ComfortPoint Programmable Lon, VAV/Unitary Controllers Controller Model Programmable Type Universal Inputs (UI) Table 1. Controller configurations. Digital Inputs (DI) PRODUCT DESCRIPTION INSTALLATION

More information

7 ZONE VALVES. Applications

7 ZONE VALVES. Applications 7 ZONE VALVES Designed to fit in compact areas where On/Off control is required. Actuator installation is a snap with an easy, one-handed removal or engagement. Actuator has a synchronous motor that winds

More information

VC7936 Floating Cartridge/Cage Valve

VC7936 Floating Cartridge/Cage Valve Floating Cartridge/Cage Valve PRODUCT DATA Specifications The specifications following are nominal and conform to generally accepted industry standards. Honeywell is not responsible for damages resulting

More information

V4062A,B,D HI-LO-OFF Fluid Power Gas Valve Actuator

V4062A,B,D HI-LO-OFF Fluid Power Gas Valve Actuator V4062A,B,D HI-LO-OFF Fluid Power Gas Valve Actuator PRODUT DATA APPLIATION The V4062 Gas Valve Actuator in combination with a V5055, VE5000 a or V5097 Gas Valve provides three-position control of the gas

More information

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem 352, 3-Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.

More information

Automatic Heat/Cool Changeover

Automatic Heat/Cool Changeover -0 odels -000/000/00/00 he 000 panel provides intelligent control of forced air zoning systems with up to eight zones using motorized dampers and practically any off-the-shelf heat/cool thermostat can

More information

G780, 3-Way, Mixing Flanged Globe Valve

G780, 3-Way, Mixing Flanged Globe Valve G780, 3-Way, Mixing langed Globe Valve pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable

More information

Series 41 and 81 Modutrol IV Motors

Series 41 and 81 Modutrol IV Motors Series 4 and 8 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 4 and Series 8 Modutrol IV Motors are 2-position (line- and low- voltage control, respectively) spring-return motors. They

More information

KVC7934, KVC7936. Modulating Actuators without and with Power Failure Reposition For KVC Series Cartridge Valve. Specifications 12.

KVC7934, KVC7936. Modulating Actuators without and with Power Failure Reposition For KVC Series Cartridge Valve. Specifications 12. Modulating Actuators without and with Power Failure Reposition For KVC Series Cartridge Valve Specifications The specifications following are nominal and conform to generally accepted industry standards.

More information

VB-7000 Series 1/2 to 2 Globe Valves

VB-7000 Series 1/2 to 2 Globe Valves V-7000 Series 1/2 to 2 Globe Valves with MG350V Series SmartX ctuators schneider-electric.com 1 Product Description Schneider Electric MG350V non-spring actuators and V-7000 series two and three-way globe

More information

L404F,T,V PressureTrol Controllers

L404F,T,V PressureTrol Controllers L404F,T,V PressureTrol Controllers PRODUCT DATA FEATURES Models available in a series of control ranges, and pressure scales in kpa and psi. All models automatically reset and have an adjustable differential.

More information

ervi Description AppGcationr

ervi Description AppGcationr ervi Description The VP5268 ThreeWay High Pressure Water Valve is a threeway mixing valve with am integral pneumatic actuator used in fan coil units having hot and/or chilled water coils. Three design

More information

ACTIVAL Three-Way Ball Valve with Threaded-End Connection

ACTIVAL Three-Way Ball Valve with Threaded-End Connection -6209 Specifications/Instructions CTIVL Three-Way all Valve with Threaded-End Connection General CTIVL Model VY5303 is a three-way ball valve with threaded-end connection (ISO 7-1: 1994). It proportionally

More information

B278, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B278, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem 28, 2-Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.

More information

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function Mixing valves and actuators 610-611 - 612-63 series RIT ISO 01 M 214 LI 01169/17 replaces dp 01169/09 unction The mixing valves allow the centralisation heating system to be regulated by mixing the boiler

More information

FEATURES APPLICATION PRODUCT DATA

FEATURES APPLICATION PRODUCT DATA M640,M740F,M6435,M7435F ctuators V5852, V5853, V5862, V5863 Valves 40.5 L (80N) NON-SPRING ND SPRING RETURN CTUTORS ND /2 INCH, 3/4 INCH CRTRIDGE GLOE VLVES FETURES PRODUCT DT Small size allows installation

More information

The ES /118 Explosion-Proof Housings

The ES /118 Explosion-Proof Housings Explosion-Proof Housings The ES-650-117/118 Explosion-Proof Housings are used to enclose Modutrol Motors used in hazardous locations. NEMA 7 and NEMA 9 enclosures. Housing meets NEC requirements for Class

More information

C7046A,B,C,D Air Temperature Sensors

C7046A,B,C,D Air Temperature Sensors C7046A,B,C,D Air Temperature Sensors FEATURES PRODUCT DATA APPLICATION The C7046 series of Air Temperature Sensors function as primary and/or secondary sensors in electronic control systems. C7046A,C Sensors

More information

Submittal. THBP Horizontal Low Profile Plenum Return FCU-THBP Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal. THBP Horizontal Low Profile Plenum Return FCU-THBP Top View (Drain Pan Omitted) Bottom View. Front View. U-THBP-.0 03-0-8 THBP Horizontal Low Profile Plenum Return Top View (rain Pan Omitted) Bottom View ront View Left hand unit shown. ll dimensions are inches [millimeters]. Side View [8] 26 [6] [06] [270]

More information

V5011N Two-Way Threaded Globe Valve

V5011N Two-Way Threaded Globe Valve VN Two-Way Threaded Globe Valve FEATURES PRODUCT DATA Red brass body with NPT-threaded end connections. Low seat leakage rate (. percent of C v ). : rangeability per VDI/VDE 7. Spring-loaded, self-adjusting

More information

VisionPRO 8000 Thermostats

VisionPRO 8000 Thermostats VisionPRO 8000 Thermostats INSTALLER SETUP AND SYSTEM TEST POCKET GUIDE 62-0266 INSTALLER SETUP 1. Press SYSTEM. FAN ON AUTO Inside SYSTEM HEAT AM SCHED HOLD M24079 2. Press and hold these two blank buttons

More information

VG4000 Series VG4000 Electric Zone Valves

VG4000 Series VG4000 Electric Zone Valves VG4000 Series VG4000 Electric Zone Valves VG4000 Electric Zone Valves VG4000 Series High-Capacity/High-Closeoff Electric Zone Valves are designed to regulate the flow of water in response to the demand

More information

CONTROL VALVES CONTROL VALVES BALL VALVES VBN2, VBN3 SERIES DESCRIPTION FEATURES SPECIFICATIONS

CONTROL VALVES CONTROL VALVES BALL VALVES VBN2, VBN3 SERIES DESCRIPTION FEATURES SPECIFICATIONS ONTROL VLVS LL VLVS VN2, VN SRIS SRIPTION The VN2 and VN Series are Honeywell's characterized flow, low torque, two- and three-way ball valves. They are designed to provide v ratings that closely match

More information

V4062A,B,D HI-LO-OFF Fluid Power Gas Valve Actuator

V4062A,B,D HI-LO-OFF Fluid Power Gas Valve Actuator V406A,B,D HI-LO-OFF Fluid Power Gas Valve Actuator PRODUT DATA APPLIATION The V406 Gas Valve Actuator in combination with a V5055 or V5097 Gas Valve provides three-position control of the gas supply to

More information

- Application A Mixing Setpoint Control 153. Mechanical. Electrical 12/08

- Application A Mixing Setpoint Control 153. Mechanical. Electrical 12/08 Mixing Setpoint ontrol - Application A -1 12/08 Mechanical 24 V (ac) SW2 SW1 V1 Additional zones Electrical M1 = Actuating Motor 741-24V (ac) Floating Action = Heating Load Pump = System Pump = Mix Supply

More information

Sequence of Operation. Installation. Commissioning. Testing and replacement of dampers and actuators. Troubleshooting. Maintenance

Sequence of Operation. Installation. Commissioning. Testing and replacement of dampers and actuators. Troubleshooting. Maintenance 0 Helgesen Drive, Madison, WI (0) -, (00) -, Fax: (0) - support@renewaire.com www.renewaire.com Supplemental Instructions for Optional Isolation Dampers for HEX Indoor Models Purpose of this Manual: To

More information

ELECTRIC ACTUATORS 400 N

ELECTRIC ACTUATORS 400 N ELECTRIC CTUTORS 400 N SE4 PPLICTION Electric actuator SE4 is suitable to drive valve body series in HVC systems. Two action types are available: - floating (3-point) - modulating Vdc and m. ctuator is

More information

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed f use in SI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem / Series Characterized Control Valve, Spring ctuator Two-way and Three-way Valves with Chrome Plated rass all and rass Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: mbient Temp

More information

1 DESCRIPTION 2 WORKING PRINCIPLE 2.1 REGULATION ST

1 DESCRIPTION 2 WORKING PRINCIPLE 2.1 REGULATION ST PRESSURE INDEPENDENT ONTROL VLVE - P.I..V. ST.01.34.00 RT. 2136 RT. 2137 1 DESRIPTION The valves art. 2136 and 2137, better known by the acronym PIV (Pressure Independent ontrol Valve), have been designed

More information

SUPERSEDES: August 15, 2005 EFFECTIVE: June 1, 2009 Plant ID#

SUPERSEDES: August 15, 2005 EFFECTIVE: June 1, 2009 Plant ID# Instruction Sheet iseries - Setpoint () 2-Way, -Way and 4-Way iseries Mixing Valves 02-44 SUPERSEDES: ugust 5, 2005 EFFETIVE: June, 2009 Plant ID# 00-026 WRNING: Do not use iseries products for potable

More information

Immersion Wells and Compression Fittings FOR TEMPERATURE CONTROLLERS

Immersion Wells and Compression Fittings FOR TEMPERATURE CONTROLLERS Immersion Wells and Compression Fittings FOR TEMPERATURE CONTROLLERS FEATURES PRODUCT DATA 107324A ELEMENT HOLDER APPLICATION 121371B IMMERSION WELL 112632AA IMMERSION WELL 104484A COMPRESSION FITTING

More information

SELECTION. Easily Selectable Easily Serviceable. Interchangeability as easy as 1-2-3

SELECTION. Easily Selectable Easily Serviceable. Interchangeability as easy as 1-2-3 SELETION Terminal Unit Zone Valve 1 Select your valve body Female Thread Solder ouble Union 2 Select your cartridge type hoice of V Hot and hilled Water 50% Glycol Low Pressure Steam Pressure alanced Male

More information

2-Port and 3-Port Zone Valves, PN16

2-Port and 3-Port Zone Valves, PN16 4 867 2-port valves MVI421.15 to MVI421.25 2-Port and 3-Port Zone Valves, P16 3-port valves MXI421.15 to MXI421.25 MVI421... MXI421... Operating voltage C 230 V, 2-position control signal Spring return

More information

VB-9313 Series. Application. Features. Applicable Literature

VB-9313 Series. Application. Features. Applicable Literature V-9313 Series 2-1/2" and 3" Screwed NPT 2-1/2" to 6" 125 Lb. Flanged Three-Way Mixing s General Instructions pplication V-9313 series three-way mixing valves control hot or chilled water in heating or

More information

VGF Flanged Globe Valves

VGF Flanged Globe Valves VGF Flanged Globe Valves PRODUCT DATA VGF2 VGF3 APPLICATION VGF Flanged Globe Valves are used for 2-position or modulating control of steam, hot water, or chilled water in closed loop HVAC systems. They

More information

2-Port and 3-Port Zone Valves & Actuators, PN16

2-Port and 3-Port Zone Valves & Actuators, PN16 2-port valve & actuator MVI421../2 3-port valve & actuator MXI421../2 2-Port and 3-Port Zone Valves & ctuators, P16 MVI421../2 MXI421../2 Operating voltage C 230 V, 2-position control signal Spring return

More information

MK Series High Performance Butterfly Submittal/Technical Data

MK Series High Performance Butterfly Submittal/Technical Data MK Series igh Performance utterfly Submittal/Technical ata ray MK Series igh Performance utterfly Valves NSI lass 150 and 300 ray ontrols ommercial ivision 13788 West Road, Suite 200 ouston, Texas 77041

More information

atalog /US asic eatures llen ey Sensor Locking lip ircuit ressure /12 5/32" Tube Instant onnections Driving ressure U xhaust ack ressure Thresho

atalog /US asic eatures llen ey Sensor Locking lip ircuit ressure /12 5/32 Tube Instant onnections Driving ressure U xhaust ack ressure Thresho Threshold Sensors... 2-3 locking Valves...4 3-Way, 2-osition Standard Duty... 5-8 Technical Data...9 Dimensions... 10-11 3-Way Miniature...12 Dimensions... Miniature and Standard Duty Limit Switches, ylinder

More information

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C ulletin 617 Rev. Model R ommercial Riser Riser Manifold for ommercial pplications ulletin 617 Rev. vailable Sizes/Pressure Ratings: 1 1 / 2 (40mm) and 2 (50mm) Threaded - 250 psi (17,2 bar) Working Pressure

More information

16.Control Valve Body

16.Control Valve Body ONTROL VLVE OY UTOMTI TRNSMISSION 16.ontrol Valve ody : REMOVL 1) Lift-up the vehicle. 2) lean the transmission exterior. 3) rain the TF completely. Tighten the TF drain plug after draining the TF. Replace

More information

Modulating Water Valves and Bulb Wells

Modulating Water Valves and Bulb Wells Modulating Water Valves and ulb Wells PPLITION: These modulating valves regulate the flow of water to the heat exchanger to maintain a desired exiting oil temperature. They open automatically when temperature

More information

AT120A-E; AT140A-E; AT150A,B,D-F; AT160B; AT175A-D,F Transformers

AT120A-E; AT140A-E; AT150A,B,D-F; AT160B; AT175A-D,F Transformers AT0A-E; AT0A-E; AT50A,B,D-F; AT60B; AT75A-D,F Transformers FEATURES PRODUCT DATA AT0 is rated at 0 VA. AT0 is rated at 0 VA. AT50 is rated at 50 VA. AT60 is rated at 60 VA. AT75 is rated at 75 VA. All

More information

2-Port and 3-Port Zone Valves, PN 16 / 20

2-Port and 3-Port Zone Valves, PN 16 / 20 4 867 2-port valve MVI421.15 to MVI421.25 3-port valve MXI421.15 to MXI421.25 2-Port and 3-Port Zone Valves, P 16 / 20 Max. permissible pressure 2000 kpa MVI421.. MXI421.. Operating voltage C 230 V, 2-position

More information

DIST. AUTORIZADO. Design Features

DIST. AUTORIZADO. Design Features IST. UTORIZO MX (55) 53 63 23 31 Kopper Kool rakes opper disc design for high heat dissipation xternal air and water connections ccurate control igh Temperature O-Rings New friction material lasts longer

More information

EEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2

EEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2 atalog: 16541 Issue ate: 6.11 Including the S/S and H/H Models ost-effective MI Power Inlet Filter UL Recognized S ertified V pproved 2 / 2 1 / 1 P / P Series ompact single stage MI filter with I 63-1

More information

TRF.. series spring return rotary actuators for CCV

TRF.. series spring return rotary actuators for CCV TF.. series spring return rotary actuators for CCV Spring return rotary actuators: For ball valves DN 5.. Torque: 2 Nm Modulating control TF24-S (C/DC 24 V) Floating (3-point) control TF24-2 (C/DC 24 V)

More information

SUPERSEDES: August 15, 2005 EFFECTIVE: June 1, 2009 Plant ID#

SUPERSEDES: August 15, 2005 EFFECTIVE: June 1, 2009 Plant ID# Instruction Sheet iseries - Reset () 2-Way, -Way and 4-Way iseries Mixing Valves 02-45 SUPERSEDES: ugust 5, 2005 EFFETIVE: June, 2009 Plant ID# 00-025 WRNING: Do not use iseries products for potable water

More information

SUPERSEDES: August 1, 2003 EFFECTIVE: August 15, 2005 Plant ID#

SUPERSEDES: August 1, 2003 EFFECTIVE: August 15, 2005 Plant ID# Instruction Sheet iseries - Reset () 2-Way, -Way and 4-Way iseries Mixing Valves 02-45 SUPERSEDES: ugust, 200 EFFETIVE: ugust 5, 2005 Plant ID# 00-025 WRNING: Do not use iseries products for potable water

More information

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 3000 SERIES Bronze, Normally Closed, Direct Lift Installation Instructions WARNING: These instructions

More information

VB-9313 Series. Application. Features. Applicable Literature

VB-9313 Series. Application. Features. Applicable Literature V-9313 Series 2-1/2" and 3" Screwed NPT 2-1/2" to 6" 125 Lb. Flanged Three-Way Mixing s General Instructions pplication V-9313 series three-way mixing valves control hot or chilled water in heating or

More information

MVN Rotary Valve Actuators FOR CONTROL BALL VALVES VBG (DN15 TO DN32)

MVN Rotary Valve Actuators FOR CONTROL BALL VALVES VBG (DN15 TO DN32) MV Rotary Valve ctuators FOR COTROL LL VLVES VG (D5 TO D) PPLICTIO MV m Control Valve Rotary Valve ctuators are used with the VG -way and the VG -way Control all Valves to control hot and chilled water

More information

G600 Series Replacement Intermittent Pilot Ignition Controls

G600 Series Replacement Intermittent Pilot Ignition Controls Installation Instructions G600 Issue Date 0601 G600 Series ment Intermittent Pilot Ignition Controls Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information

TECHNICAL FEATURES MOTORIZED VALVES USE. Data sheet

TECHNICAL FEATURES MOTORIZED VALVES USE. Data sheet USE motorized valve is specifically used for the interception and regulation of fluids in: heating/cooling systems (HV) drinking water systems systems using alternative energy household automation systems

More information

MT4-024/MT4-230 MT8-024/MT8-230

MT4-024/MT4-230 MT8-024/MT8-230 Smart-T MT4-024/MT4-230 MT8-024/MT8-230 SMLL LINER THERMOELECTRIC CTUTORS FETURES PRODUCT DT No mounting tools required (easily mounted using valve adapter) Water-protected housing design in all mounting

More information

CALEFFI. Differential pressure by-pass valve. 519 series 01007/14 NA. Replaces 01007/12 NA

CALEFFI. Differential pressure by-pass valve. 519 series 01007/14 NA. Replaces 01007/12 NA ifferential pressure by-pass valve RIT LFFI series / N ISO FM ISO No. Replaces / N Function The differential pressure by-pass valve is used in systems with a fixed speed circulating pump supplying several

More information

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 13000 SERIES Stainless, Normally Closed, Direct Lift, 3-Way Valve Installation Instructions WARNING:

More information

MV100 Electric Controllers T100, T200 Thermostatic Controllers and V2000 Radiator Valves

MV100 Electric Controllers T100, T200 Thermostatic Controllers and V2000 Radiator Valves MV100 Electric Controllers T100, T200 Thermostatic Controllers and V2000 Radiator Valves PRODUCT DT THERMOSTTIC CONTROLS T100 T100M PPLICTION The MV100, T100, T200 Controllers, when paired with V2000 Radiator

More information

FV2000 SERIES VALVE FV-SERIES VALVES

FV2000 SERIES VALVE FV-SERIES VALVES V00 SS VLV The ulflo V00 Series valve is similar to the V-Series valve, includes a new safer design that protects liquid and gasses from venting out of the valve during normal operation and adjustment

More information

SRB Series. UL Recognized CSA Certified VDE Approved* Specifications. SRB Series. Power Inlet Filters & Power Entry Modules

SRB Series. UL Recognized CSA Certified VDE Approved* Specifications. SRB Series. Power Inlet Filters & Power Entry Modules orcom Product Guide atalog: 161 Issue ate: 6.11 Minimum epth, ost-effective Shielded Power Inlet Filter SR Series UL Recognized S ertified V pproved* SRP SRS8 SR1 SR2 SR Series Smallest depth orcom RFI

More information

Tension Brakes/High Heat Capacity

Tension Brakes/High Heat Capacity IST. UTORIZO Tension rakes/igh eat apacity MX (55) 53 63 23 31 Steel Water ooled rakes ost effective design One piece water jacket eliminates leakage Release springs ensure complete disengagement New friction

More information

ML7421A,B Electric Linear Valve Actuator

ML7421A,B Electric Linear Valve Actuator ML7421A,B Electric Linear Valve Actuator FEATURES PRODUCT DATA Quick and easy installation. No separate linkage required. 3/4 in. (20 mm) stroke on ML7421A; 1-1/2 in. (38 mm) stroke on ML7421B. No adjustments

More information

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator /3 Series Characterized Control Valve, Non-Spring ctuator Two-way and Three-way Valves with Chrome Plated rass all and rass Stem, NPT Female Ends Service: Flow characteristic: Media Temp Range: mbient

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

F-Series General Specifications

F-Series General Specifications arling F-Series General Specifications F-Series breakers are available up to 700, and are also available with a 25 millivolt metering shunt construction. This optional construction provides a safe method

More information