Front. Side. Back POWER HURRICANE (30 ) 29 3/4, (36 ) 35 7/8 14 3/4 22 1/ /16 3 1/4 C/L. and stainless steel. Now with ACT technology.

Size: px
Start display at page:

Download "Front. Side. Back POWER HURRICANE (30 ) 29 3/4, (36 ) 35 7/8 14 3/4 22 1/ /16 3 1/4 C/L. and stainless steel. Now with ACT technology."

Transcription

1 POWR URRIN UNR-INT TM igh tech meets high style with an updated look and feel. lectronic touch controls take charge of the 3-speed, 695-M blower and dual-level halogen lights-all designed to make your life easier. vailable in black, white and stainless steel. Now with T technology. ZPYRONLIN.OM INTRNL LOWR STNR INTRNL LOWR with T IRLOW ONTROL TNOLOY * Min. - Max. M Min. - Max. Sones *IRLOW ONTROL TNOLOY (T ) is an exclusive feature built into specific Zephyr hoods which can limit the maximum blower M to meet local code requirements. (30 ) 29 3/4, (3) 35 7/ ront Side 1 1/1 3 1/4 14 3/4 3 1/4 Stainless Steel 22 1/ lack /L ack White

2 POWR URRIN UNR-INT ZPYRONLIN.OM lack White Stainless Steel K2500 K2500W K2500S K2536 K2536W K2536S Size lower M (Min. - Max.) Sones (Min. - Max.) T 390 M (Min. - Max.) T 390 Sones (Min. - Max.) T 290 M (Min. - Max.) T 290 Sones (Min. - Max.) 30 (29-3/4 ) (35-7/) T Technology ontrols Speed Levels uto elay-off Lighting ual-level Lighting Removable Safety rilles Recirculating Option Self leaning lectronic Touch 3* alogen, 35W x2 2 No lectronic Touch 3* alogen, 35W x2 2 No UT SPIITIONS Vertical Internal lower orizontal Internal lower POWR Round or x x 120V, 60z at Max. 2.4 Round or x x 120V, 60z at Max. 2.4 OPTIONL SSORIS Make-Up ir Kit MOUNTIN IT RN** MU MU WRRNTY 10 years parts, 1 year labor 10 years parts, 1 year labor *When T is enabled the maximum speed levels will change. T 390 M = 2 speeds and T 290 M = 1 speed. **Mounting height refers to distance between top of a 3 tall cooking surface and bottom of hood. TM IRLOW ONTROL TNOLOY (T ) is an exclusive feature built into specific Zephyr hoods which can limit the maximum blower M to meet local code requirements. Specifications subject to change, check zephyronline.com for up-to-date information. Zephyr Ventilation 2277 arbor ay Parkway, lameda, VNT

3 UNIVRSL MK-UP IR MPR When range hoods exhaust air out of your home, negative air pressure is created unless the exhausted air is replaced by fresh outdoor air. Zephyr s Universal Make-Up ir amper is designed to balance the air pressure in your home by automatically opening to allow fresh air in while the range hood is operating. or use with any Zephyr hood operating over 300 M. 9 MU006 MPR round M LVL of range hood motor up to 600 M MU006 Make-Up ir amper MU008 round up to 1,000 M MU010 round up to 1,200 M V, 60 z motor Meets International Residential ode M utomatically opens when range hood is operating utomatically closes when range hood is off 24-gauge galvanized steel construction djustment screw to adjust damper opening MU008 Make-Up ir amper OPTIONL SSORIS K00030 resh air inlet cap with screen, round K00032 resh air inlet cap with screen, round K00052 resh air inlet cap with screen, round 13 Typical Installation PRSSUR SWIT Mounts to ducting in hood and communicates with make-up air damper via low-voltage signal wires. MU010 Make-Up ir amper Transformer Installs next to damper. Included with MU006, MU008 & MU010 central return air fresh air inlet signal wires Pressure Switch omponents Included with MU006, MU008 & MU010 MPR OT arbor ay Pkwy lameda, VNT

4 K RT MPR round damper to prevent return-air from entering kitchen K00029 K00049 K00069 UT IMNSIONS 2-7/ 2-7/ 1/4 1/2 3-5/ 3-5/ 3/4 - Vertical uct pplication - oam Seal for amper losure - alvanized (-90) - NOT OR US WIT RYR VNT PPLITIONS Side View TPR RUR Reduces round duct size K00039 K00037 K00035 K00040 UT IMNSIONS 7x 8x 8x 5 10x 5 4-3/4 4-1/4 - Tapered for est ir low - alvanized (-90) Side View arbor ay Pkwy lameda, VNT

5 ROO P XUST, J-VNT xhaust cap for round ducting, installs on roof K00046 K00047 K00048 K00050 UT IMNSIONS I / 1-7/ / / / / 5-1/2 3-1/2 1-7/ 2 6-1/2 4-1/4 2-1/4 3-1/2 - Low Profile - Install of ny Roof Pitch - alvanized (-90) I Side View WLL P XUST, x RTNULR xhaust cap for rectangular ducting, prevents return-air, installs on exterior wall K00041 IMNSIONS 5-5/ /4 9-1/2 - luminum amper Included - Rain Proof - alvanized (-90) - NOT OR US WIT INLT VNT PPLITIONS ront View arbor ay Pkwy lameda, VNT

6 WLL P XUST, ROUN xhaust cap for round ducting, prevents return-air, installs on exterior wall K00042 K00043 K00044 K00045 UT IMNSIONS 7-5/ 1 8-1/ / 9-5/ 1 8-1/2 11-5/ 8-1/ /2 10-3/4 10-3/ 11-1/2 8-5/ 9-5/ 11-1/ 13-5/ 7-1/ 8-1/ 10-3/ 13-7/ - luminum amper Included - Rain Proof - alvanized (-90) ack View WLL P INLT, ROUN resh air inlet for round ducting, commonly used with make-up air kits K00030 K00031 K00032 UT IMNSIONS 7-5/ 1 8-1/ / 9-5/ 1 8-1/2 11-5/ 8-1/2 10-3/4 10-3/ 8-5/ 9-5/ 11-1/ 7-1/ 8-1/ 10-3/ - Rain Proof - alvanized (-90) ack View arbor ay Pkwy lameda, VNT

Front. Side. Back POWER TYPHOON 7 7/8 (30 ) 29 3/4, (36 ) 35 3/4 (42 ) 41 3/4, (48 ) 47 11/ / / /16 3 1/4 C/L

Front. Side. Back POWER TYPHOON 7 7/8 (30 ) 29 3/4, (36 ) 35 3/4 (42 ) 41 3/4, (48 ) 47 11/ / / /16 3 1/4 C/L POWR TYPOON UNR-INT TM One of our founding models, now with an updated look, we crafted a smooth curvature then upped the volume with powerful, virtually noise-free 850-M blowers. convenient self-cleaning

More information

MONSOON I FRONT TOP BACK (28 ) 9-1/4 (34 ) 12-1/4 (40 ) 15-1/4 (46 ) 18-1/4 2 (28, 34 ) 5-5/8 (40, 46 ) 5-7/8 *1-1/2. elec. k/o

MONSOON I FRONT TOP BACK (28 ) 9-1/4 (34 ) 12-1/4 (40 ) 15-1/4 (46 ) 18-1/4 2 (28, 34 ) 5-5/8 (40, 46 ) 5-7/8 *1-1/2. elec. k/o POWR MONSOON I one-piece liner TM Monsoon I has taken the one-piece liner to the next level. Including dual-level halogen lights and an -compliant R remote you can easily control Monsoon I without ever

More information

Direct-Fired Heating, Ventilation and Pressurization Systems

Direct-Fired Heating, Ventilation and Pressurization Systems 2000-Series irect-ired Heating, Ventilation and Pressurization Systems imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% OUTSI IR ONLY 2000-Series Selection uide NOT: ll information

More information

Direct-Fired Heating, Ventilation and Pressurization Systems

Direct-Fired Heating, Ventilation and Pressurization Systems 2000-Series irect-ired Heating, Ventilation and Pressurization Systems imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% Outside ir Only 2000-Series Selection uide M (m 3 /h)

More information

Air Handlers Series. Direct-Fired Heating Pressurization. Dimension and Selection Guide

Air Handlers Series. Direct-Fired Heating Pressurization. Dimension and Selection Guide 2000-Series ir andlers irect-ired eating Pressurization imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% OUTSI IR ONLY 2000-Series Selection uide IMPORTNT NOTS: ll information

More information

KITCHEN VENTILATION SOLUTIONS

KITCHEN VENTILATION SOLUTIONS KITHN VNTILTION SOLUTIONS HOO LINRS XHUST NS SILNRS IMPROVING INOOR IR QULITY THROUGH TTR VNTILTION June 0 SK00 www.fantech.net KITHN VNTILTION SOLUTIONS Today s kitchens have become much more than a place

More information

Z % OUTSIDE AIR (US & CANADA) Z RECIRCULATION (US) Z PROCESS HEATER (US AND CANADA)

Z % OUTSIDE AIR (US & CANADA) Z RECIRCULATION (US) Z PROCESS HEATER (US AND CANADA) Z83.4 100% OUTI IR (U & ) Z83.18 - RIRULTIO (U) Z83.25 - RO TR (U ) TT112 & TT115 orizontal Model L L R Y J IR MR URR / LOWR TIO ILTR TIO ILT MR ILT OO WIT IRR M X W I V Z Z T K V Q R R 2 IMIO MOL J K

More information

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572 FEATURES Computer designed, efficient performance, forward curved blower. Blower wheel hub is secured to the shaft with a locking keyway. Blower is secured to anti-vibration mounts within the cabinet.

More information

Model PCD Indirect-Fired, Vertical/Horizontal, Indoor/Outdoor, Packaged, Makeup Air Heating and Air Conditioning System

Model PCD Indirect-Fired, Vertical/Horizontal, Indoor/Outdoor, Packaged, Makeup Air Heating and Air Conditioning System Model P Indirect-Fired, Vertical/Horizontal, Indoor/Outdoor, Packaged, Makeup Heating and onditioning System USTOMR QS NY ONVRNT QULITY SYSTM PROUT PROSS STRT-UP WRRNTY ontents MOLS P, HP SRIPTION... 2

More information

CEILING VENTILATOR ACCESSORIES 6393 Powers Avenue Jacksonville, Florida P: / F:

CEILING VENTILATOR ACCESSORIES 6393 Powers Avenue Jacksonville, Florida P: / F: EILING VENTILTOR ESSORIES IN-LINE PTOR KITS FOR FF UNITS 961L IN-LINE PTOR KIT Fits FF100 & FF150 For 6" Round uct Intake 982L IN-LINE PTOR KIT Fits FF400, FF500 & FF700 4 1/2" x 18 1/2" uct Intake 981L

More information

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Commercial & Industrial Ventilation Complete Line of Sustainable Products

Commercial & Industrial Ventilation Complete Line of Sustainable Products ommercia l Kitchen Ventilation ommercial & Industrial Ventilation omplete Line of Sustainable Products 919.88.4 800.334.956 919.88.504 (fax) www.captiveaire.com ontents entrifugal Upblast xhaust Fans N-F

More information

Inline, Ceiling and Sidewall Exhaust

Inline, Ceiling and Sidewall Exhaust SP, SP 38 Inline, eiling and Sidewall xhaust SP SP UL/cUL 507-33599 - eiling xhaust Fans SP-390 and smaller and SP- are UL/cUL Listed for above bathtub/shower with GFI branch protected circuit. SP- is

More information

Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed Tag: Project: Engineer: Contractor: Location: ate: pplication: rchitect: Submitted by: The NC model F fire damper utilizes a curtain style blade to prevent the spread of fire through a penetration in a

More information

5/8 (16) DIA. MOUNTING HOLES TYP [4] PLACES. SEE NOTE #3 ACCESS PANEL BOTH SIDES 2 1/2 (64) Unit Size Fan Size L W H C D E F G J (508) (406) 25 (635)

5/8 (16) DIA. MOUNTING HOLES TYP [4] PLACES. SEE NOTE #3 ACCESS PANEL BOTH SIDES 2 1/2 (64) Unit Size Fan Size L W H C D E F G J (508) (406) 25 (635) LOER OILS, orizontal and ertical imensional Information TOP N SIE IES (RR 3) LOER OILS 9/ (4) I. MOUNTING OLES TYP [4] PLES. ITOUT SE RIL NOTES:. Provide sufficient clearance to permit access to controls

More information

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Inline & Sidewall Exhaust Fans

Inline & Sidewall Exhaust Fans F, F 28 Inline & Sidewall xhaust Fans est vailable 3 ays F UL/cUL 705 Power Ventilators 40001 - F with TF motors 40001 - F with TF motors F F is M Licensed for ir Performance F is M Licensed for Sound

More information

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES

More information

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES

More information

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING -

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS MODEL FEATURES Supply air to over 56,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Filtered models available

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WLL-MOUNT -TON IR CONDITIONERS J7 - Right Side Control Panel J7L - Left Side Control Panel, 9.5 EER Hz Solair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to

More information

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

RKB. Heat recovery units from 100 to m 3 /h >50 %

RKB. Heat recovery units from 100 to m 3 /h >50 % 12 Lmf Clima 216 FRRRO GROUP RKB eat recovery units from to 5.4 m 3 /h Sheet metal supporting frame and double shell curtain panels externally pre-painted, fully removable with 2 mm thick internal thermal

More information

HIGH PRESSURE RADIAL PRESSURE BLOWERS

HIGH PRESSURE RADIAL PRESSURE BLOWERS Twin ity an INUSTRIL PROSS N OMMRIL VNTILTION SYSTMS I PRSSUR RIL PRSSUR LOWRS MOL RO MOL RS TLO 10 MY 12 WWW.T.OM I PRSSUR LOWRS OVRVIW RO I RS Model RO and RS fans from Twin ity an & lower are specifically

More information

R E P L A C E M E N T P A R T S

R E P L A C E M E N T P A R T S R P L M N T P R T S M a y 2 0 1 3 www.fieldcontrols.com Replacement OMUSTION S SRIS OMUSTION IR SYSTMS S-2 S-2 S-2W S-290 S-290 S-2 S-2 375 S-2 S-3 S-4 S-4P S-4Jr. S-4mV S-6* S-7* VRV-4 46257100 IH-4 Intake

More information

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD

More information

D F B. DFBH Rooftop Unit DFBV

D F B. DFBH Rooftop Unit DFBV SYSTEM, UAL LOWER MOEL H Rooftop Unit V ive Sizes H - Horizontal Configuration with ull Curb Cap ase and either Horizontal or Vertical (down) ischarge V - Vertical Configuration with Horizontal ischarge,

More information

Americraft is dedicated to assist you, our customer, in all aspects of your air moving requirements.

Americraft is dedicated to assist you, our customer, in all aspects of your air moving requirements. mericraft Manufacturing Company Inc. has been manufacturing quality industrial fans and ventilation products since 1946. Our 50+ years of proven experience, strong national reputation and excellent customer

More information

DOUBLE ENVELOPING WORM GEAR SETS

DOUBLE ENVELOPING WORM GEAR SETS OUL NVLOPIN WORM R STS 172 one rive Product atalog and ngineering Manual ouble nveloping Worm ears & Speed Reducers ontents one rive ear Sets...173 one rive ear Sets - Tables of acklash... 174 one rive

More information

GE Monogram 48" Built-In Side-by-Side Refrigerator

GE Monogram 48 Built-In Side-by-Side Refrigerator OVRLL IMNSIONS 25 1/2" (64.8) 48" (121.9) 23 7/8" (60.7) 1 3/4" (4.4) 13 1/2" (34.3) *84" (213.4) *83 1/2" (212.1) 68 1/2" (174.0) *72 1/4" (183.5) *40" (101.6) SPIITIONS Overall Width Overall Height Overall

More information

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

483 mm (19 ) Wall Mounting Cabinets IP55 (Outdoor), 600 mm width mm, 600 mm depth

483 mm (19 ) Wall Mounting Cabinets IP55 (Outdoor), 600 mm width mm, 600 mm depth 483 mm (19 ) Wall Mounting Cabinets IP55 - Outdoor 1.5 mm strong steel sheet Safety class IP 55 Integrated air ventilation inlets Available with double wall structure Abstract 483 mm (19 ) Wall Mounting

More information

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS S CSF & LSF Model CSF Hooded Design FEATURES Supply air to over 13,000 CFM in static pressure capabilities to 2 w.g. Heavy-galvanized construction Belt drives permit easy performance adjustments when needed

More information

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

MULTI-PORT MONOBLOCK VALVE HMB & 2BE SERIES

MULTI-PORT MONOBLOCK VALVE HMB & 2BE SERIES MULTI-PORT MONOLOK VLV M & 2 SRIS IPRM MONOLOK VLV OR US & UROP MRKT M SRIS MTRILS O ONSTRUTION - WTT PRTS Item No. Parts Material 1 ody SS316L Var or Vim/Var (1) 2 Seat older SS316L Var or Vim/Var (1)

More information

Direct Gas-Fired Make-up Air Heaters

Direct Gas-Fired Make-up Air Heaters Direct Gas-Fired Make-up Air Heaters SDM-E SERIES OUTDOOR SPECIFICATIONS MANUAL MANUFACTURED BY : BROTHERS LIMITED TABLE OF CONTENTS Summary description of the unit...4 Required burner capacity...6 Dimensions

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

Monogram 36" Built-In Side-by-Side Refrigerator

Monogram 36 Built-In Side-by-Side Refrigerator Monogram 36" uilt-in Side-by-Side Refrigerator STION 1 LUSH INST INSTLLTION STION 2 STNR INSTLLTION 1/4" RM PNLS 3/4" OVRLY PNLS OVRLL IMNSIONS TR PNL INSTLL LUSH INST INSTLLTION 38" (96.5) 26" (66.0)

More information

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE.  By Vent-A-Hood Vline By Vent-A-Hood V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE Vline By Vent-A-Hood POWER LUNG BRINGS LUXURY & SUPERIOR PERFORMANCE TO THE VALUE RANGE HOOD CATEGORY Vent-a-hood s

More information

2 Saudi Fan Industries

2 Saudi Fan Industries 1 2 3 4 5 6 7 The fan housing is constructed of heavy gauge Galvanized steel sheet with a rigid internal support structure the 8 Product Features design 9 Square Inline Centrifugal Fan ISQ 300 Performance

More information

Anti-Pollution Ecological System

Anti-Pollution Ecological System The FST ecological system was designed to meet all types of commercial kitchen installations. The ecological system is an environmentally-friendly solution that helps maintain air quality. The main objective

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation

More information

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD

More information

Roof & Sidewall Mounted

Roof & Sidewall Mounted G, G Roof & Sidewall Mounted 4 E40001 - G and G UL/cUL Power Ventilators for Smoke ontrol Systems MH11711 - G UL/cUL Listed 705 is standard on In Stock models G and G are M Licensed for Sound and ir Performance

More information

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

WATER SOURCE HEAT PUMP WSHP

WATER SOURCE HEAT PUMP WSHP WTR SOUR HT PUMP WSHP I IR Water Source Heat Pump Units 3 onsole WSHP 4 onsole imensions 5 Vertical Stack WSHP 6 Vertical Stack imensions 7 Horizontal WSHP 8 Horizontal imensions 9 Vertical loset WSHP

More information

Greenheck Product Category

Greenheck Product Category reenheck Product ategory SW elt rive ackward nclined une 008 SW elt rive Utility ans reenheck s backward inclined utility fans have many advantages; higher operating efficiencies, non overloading horsepower

More information

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed Tag: Project: Engineer: Contractor: Location: ate: pplication: rchitect: Submitted by: The NC model F fire damper utilizes a curtain style blade to prevent the spread of fire through a penetration in a

More information

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods HEIGHT OF HOOD The bottom of the hood to should be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (182.9 cm) above the

More information

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

AIR HANDLING UNITS YSE

AIR HANDLING UNITS YSE IR DIG UITS YSE YSE Series ir andling Units YORK YSE Series ir andling Units are designed to provide a comfortable environment for factories, warehouses, office and stores etc. The coils can be used to

More information

MONOGRAM 36" BUILT-IN SIDE-BY-SIDE REFRIGERATOR

MONOGRAM 36 BUILT-IN SIDE-BY-SIDE REFRIGERATOR STION 1 STNR 1/4" RM PNLS 3/4" OVRLY PNLS STION 2 LUSH INST OVRLL IMNSIONS STNR 25 1/2" (64.8) 36" (91.5) 23 7/8" (60.7) 1 3/4" (4.4) 13 1/2" (34.3) *84" (213.4) *83 1/2" (212.1) 68 1/2" (174.0) *72 1/4"

More information

Direct-Fired Air Handler

Direct-Fired Air Handler irect-fired Air Handler B-Series imension and Selection Guide 1.800.536.3461 www.bananza.com ANSI Z83.4/SA 3.7 100% OUTSI AIR (US & ANAA) Z83.18 - RIRULATION (US) ANSI Z83.25/SA 3.19 PROSS HATR (US & ANAA)

More information

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style. 120 Ventilation Ventilation Removes smoke and odor. Adds exceptional style. Ventilation 121 Ventilation Bosch s efficient, highly effective ventilation products complete any Bosch kitchen package. Capable

More information

MONOGRAM 42" BUILT-IN SIDE-BY-SIDE REFRIGERATOR

MONOGRAM 42 BUILT-IN SIDE-BY-SIDE REFRIGERATOR MONOGRM 42" UILT-IN SI-Y-SI RRIGRTOR STION 1 STNR INSTLLTION 1/4" RM PNLS 3/4" OVRLY PNLS STION 2 LUSH INST INSTLLTION MONOGRM 42" UILT-IN SI-Y-SI RRIGRTOR STNR INSTLLTION 25 1/2" (64.8) 42" (106.7) 23

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with

More information

LIST OF MATERIALS. USE, CARE, AND INSTALLATION GUIDE Read all Instructions before Installing and operating this appliance WARNING

LIST OF MATERIALS. USE, CARE, AND INSTALLATION GUIDE Read all Instructions before Installing and operating this appliance WARNING USE, CARE, AND GUIDE Read all Instructions before Installing and operating this appliance MODELS: AK7000, AK7036, AK7042 Tempest I IMPORTANT SAFETY NOTICE WARNING Installation The installation in this

More information

Ceiling and Inline Fans

Ceiling and Inline Fans Ceiling and Inline Fans Page Introduction.....................................2 Construction Features..............................3 Specifications and Dimension Data GC 122-184....................................4

More information

Industrial Fans & Blowers

Industrial Fans & Blowers Industrial Fans & Blowers PK DIRET DRIVE PNEL FNS Superior performance and sound characteristics Heavy gauge steel GRP (polypropylene) impeller available luminum construction available Sizes range from

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

200, 9200 & 9200-VIB SERIES

200, 9200 & 9200-VIB SERIES DUCT VENTILATION 200 SERIES Indoor Applications, Insulated or Non-Insulated 9200 SERIES Heavy duty, Insulated Indoor or Outdoor Applications SUBJECT TO CHANGE WITHOUT NOTICE - 04/7 Optional motor, drive

More information

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive

More information

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25 ON/OFF Professional hoods 48", 36" and 30" restaurant-style hoods 48", 36" and 30" tapered-sided hoods 48", 36" and 30" straight-sided hoods 30" under-cabinet hood ZV48RSFSS, ZV36RSFSS and ZV30RSFSS ZV48TSFSS,

More information

You Can t Buy A Better Reel. Family owned and operated since 1933

You Can t Buy A Better Reel. Family owned and operated since 1933 Spray and Pressure Washing ose Reels Pressure Washing Steam leaning Spray Operations Washdown Maintenance uto Washing Processing Plants rounds Maintenance Pest ontrol Tree Spraying Vehicle Maintenance

More information

CONTENTS. VARIABLE FREQUENCY DRIVES & SPEED CONTROLS B, EL & MC Series...35 CONTACTS...36 OTHER CANARM PRODUCTS...37

CONTENTS. VARIABLE FREQUENCY DRIVES & SPEED CONTROLS B, EL & MC Series...35 CONTACTS...36 OTHER CANARM PRODUCTS...37 V ROU S OTTS OT: FM values listed above are summarized for convenience. For full performance FM & S consult elhi s elair blower selection program or visit www.delhi-industries.com SI & TWI FORWR URV II

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Package Air onditioners - ommercial Table of ontents Model

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

2192 mm (86.3 in.) or mm (116.6 in.) mm (116.6 in.)

2192 mm (86.3 in.) or mm (116.6 in.) mm (116.6 in.) SPIITIONS ngine 640L / 648L 748L Manufacturer / Model John eere PowerTech PSS 6.8L John eerepowertech 6.8L John eere PowerTech PSS 6.8L John eere PowerTech 6.8L Off-Road mission Standards P inal Tier 4

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio PNUMTI RK N PINION TUTORS dvanced torque to size ratio eatures: Pneumatic Rack and Pinion ctuators 90 ctuation for -way valves (Straight & ngle) 180 ctuation for -way (T-type) valves ctuators comply with

More information

CONTAINER TILTERS for Every Application

CONTAINER TILTERS for Every Application ONTINR TILTRS for very pplication Improve worker productivity and safety liminate bending, stretching, & reaching HNL PRTS IN ONTINRS OR TOTS WITHOUT NING, LIFTING OR RHING ccessing parts and containers

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

MONOGRAM 42" BUILT-IN SIDE-BY-SIDE REFRIGERATOR

MONOGRAM 42 BUILT-IN SIDE-BY-SIDE REFRIGERATOR MONOGRM 42" UILT-IN SI-Y-SI RRIGRTOR STION 1 STNR INSTLLTION 1/4" RM PNLS 3/4" OVRLY PNLS STION 2 LUSH INST INSTLLTION STNR INSTLLTION 25 1/2" (64.8) 42" (106.7) 23 7/8" (60.7) 1 3/4" (4.4) 13 1/2" (34.3)

More information

MODEL FF50 CEILING FAN

MODEL FF50 CEILING FAN MODEL FF50 CEILING FAN SPECIFICATION SHEET Simple installation dependability make this odor moisture removing fan a real value. Matte white polymeric blends well with any decor Torsion spring grill mounting

More information

MONOGRAM 36" BUILT-IN SIDE-BY-SIDE REFRIGERATOR

MONOGRAM 36 BUILT-IN SIDE-BY-SIDE REFRIGERATOR MONOGRM 36" UILT-IN SI-Y-SI RRIGRTOR STION 1 STNR INSTLLTION 1/4" RM PNLS 3/4" OVRLY PNLS STION 2 LUSH INST INSTLLTION MONOGRM 36" UILT-IN SI-Y-SI RRIGRTOR OVRLL IMNSIONS STNR INSTLLTION 25 1/2" (64.8)

More information

TORIN by: AIRDEX Index Page No.

TORIN by: AIRDEX Index Page No. Index Page No. N Series Fans 2 Bladed, Heavy Duty...1 N Series Fans 3 Bladed, Free Air...2-3 N Series Fans 4 Bladed, Heavy Duty...4-5 Universal Hubs...6 One Piece Fan O Series 4 & 5 Bladed...7 One Piece

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

Viking Installation Guide

Viking Installation Guide iking Installation Guide iking Range orporation Front Street Greenwood, Mississippi 890 US (66) 455-00 For product information, call -888-IKING (845-464) or visit the iking Web site at vikingrange.com

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial

More information

Zurn Wilkins Fire Protection Series. Backflow Preventers, Pressure Regulating Valves, and Water Control Products for Fire Sprinkler Applications

Zurn Wilkins Fire Protection Series. Backflow Preventers, Pressure Regulating Valves, and Water Control Products for Fire Sprinkler Applications Zurn Wilkins ire Protection Series ackflow Preventers, Pressure Regulating Valves, and Water ontrol Products for ire Sprinkler pplications Zurn Wilkins ire Protection Series Zurn Wilkins fire protection

More information

Safety Stations with Eye/Face Wash

Safety Stations with Eye/Face Wash Safety Stations with ye/face Wash F G1950 Safety Station with ye/face Wash, Stainless Steel owl pplication: ombination eye/face wash and shower safety station. Two large FS-Plus spray-type outlet heads

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2

More information

glider glider evo kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL CLASS Energy Class

glider glider evo kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL CLASS Energy Class 115 glider glider evo air cooled liquid chillers N free cooling chillers 282 1510 1 96 3 2 0 1 3 f i f t y c o o l y e a r s RROUP Sp 19632013 fiftycoolyears LSS SHLL R OOLIN _NR_0113 R134a 116 LIR evo

More information

MPSH03CG-H05CG(D)

MPSH03CG-H05CG(D) H03-H05() Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-H03-H05()

More information

The newest addition to RenewAire s broad line of Energy Recovery Ventilators.

The newest addition to RenewAire s broad line of Energy Recovery Ventilators. INTRODUCING HE 1.5X The newest addition to RenewAire s broad line of Energy Recovery Ventilators. The perfect size for the largest number of ventilation applications in the industry: 375-1,400 CFM Advanced

More information

CA MD NEW IN-LINE CENTRIFUGAL DUCT FANS WITH TWO SPEEDS ATORTAT. DUISIM DELESTIO COMMOLOBORE h

CA MD NEW IN-LINE CENTRIFUGAL DUCT FANS WITH TWO SPEEDS ATORTAT. DUISIM DELESTIO COMMOLOBORE h NW M IN-LIN NTRIFUGL UT FNS WITH TWO SPS TORTT. UISIM LSTIO OMMOLOOR OLNISL UTPTT IP44 NONSQUM, LONG LIF 3. h VLIT, SI. VNTILTION IR ONITIONING IR LNING NG HTING NW M RNG 2 IN-LIN NTRIFUGL UT FNS WITH

More information

Reliable Ventilation Solutions

Reliable Ventilation Solutions Reliable Ventilation Solutions Residential ommercial Industrial 2017 Product atalog Pages 4 17 Residential Global Manufacturing and Operations t Kamfri, we re committed to providing the products you need,

More information