Viking Installation Guide

Size: px
Start display at page:

Download "Viking Installation Guide"

Transcription

1 iking Installation Guide iking Range orporation Front Street Greenwood, Mississippi 890 US (66) For product information, call -888-IKING ( ) or visit the iking Web site at vikingrange.com U L U L Professional Hoods F0470G EN (0)

2 Table of ontents Warnings & Important Information -4 WH 0 H. Wall Hoods w/standard entilar 4, 0, & Dimensions & Specifications 5 learance Dimensions 6 Interior entilar Dimensions 7 WH 8 H. 4 /7 Deep Wall Hoods 4, 0,, 4, 48, 54, 60, & 6 Dimensions & Specifications 8 learance Dimensions 9 Interior entilar Dimensions 0 Exterior entilar Dimensions WH 8 H. T-Series Wall Hoods, 48, & 60 Dimensions & Specifications learance Dimensions WH himney Wall Hoods 0,, 4, 48, 54, 60, & 6 Dimensions & Specifications 4 learance Dimensions 5 Interior entilar Dimensions 6 Exterior entilar Dimensions 7 IH Island Hoods, 4, 54, & 6 Dimensions & Specifications 8 learance Dimensions 9 Interior entilar Dimensions 0 Exterior entilar Dimensions IH himney Island Hoods, 4, 54, & 6 Dimensions & Specifications learance Dimensions Interior entilar Dimensions 4 Exterior entilar Dimensions 5 Wall usm entilar System Dimensions & Specifications 6 Installing Hood anopy 7 learance Dimensions 8 entilar Dimensions 9 I Island usm entilar System Dimensions & Specifications Installing Hood anopy learance Dimensions I entilar Dimensions 4 Planning Information 6 Installation Procedures Installation (WH 0 H. Wall Hoods w/standard entilar) 7 Duct over Option (WH 0 H. Wall Hoods w/standard entilar) 9 Installation (WH 0 H. Wall Hoods w/recirculating Kit) 9 Installation (WH 8 H. Wall & WH himney Wall Hoods) 4 Duct over Option (WH 8 H. Wall Hoods) 4 Duct over Option (WH himney Wall Hoods) 44 Installation (IH/IH Island Hoods) 45 Service & Registration 47 IMPORTNT Please Read and Follow! NOTE: If installing hood with warming shelf panel, install warming shelf panel first. IMPORTNT PLESE RED ND FOLLOW efore beginning, please read these instructions completely and carefully. Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. Please observe all local and national codes and ordinances. If no local codes are applicable, wire in accordance with the National Electrical ode, NSI/NFP 70-latest edition. Damp environment approved models should be installed in a covered non-enclosed area and should be protected from the elements as much as possible. The installer should leave these instructions with the consumer who should retain for local inspecr s use and for future reference. heck with a qualified and trained installer or local codes for makeup air requirement, if any. This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury persons, turn off the electricity the hood from the power supply before servicing or cleaning. iking hoods are equipped with variable speed control blowers. These units will not function with a single speed ventilar. ll iking Range ventilar kits are designed specifically for use with iking Range hoods. Use of any non-iking Range ventilar kit will void the hood warranty. iking hoods are equipped with the variable speed controls for blowers. These units will not function with a single speed ventilar. ll iking ventilar kits are designed specifically for use with iking hoods. Use of any non-iking ventilar kit will void the hood warranty. RED ND SE THESE INSTRUTIONS W R N I N G To reduce the risk of fire, electric shock, or injury persons, observe the following: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. efore servicing or cleaning unit, switch power off at service panel and lock service panel prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, the service panel. W R N I N G TO REDUE THE RISK OF FIRE, ELETRIL SHOK, OR INJURY TO PERSONS, OSERE THE FOLLOWING:. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.. Sufficient air is needed for proper combustion and exhausting of gases through the flute (chimney) of fuel burning equipment prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection ssociation (NFP), and the merican Society for Heating, Refrigeration and ir onditioning Engineers (SHRE), and the local code authorities.. When cutting of drilling in wall or ceiling, do not damage electrical wiring and other hidden utilities. 4. Ducted fans must always be vented the outdoors. 5. WRNING!: To reduce risk of fire, use only metal ductwork 6. UTION!: To reduce risk of fire and properly exhaust air, be sure duct air outside. Do not vent exhaust air in spaces within walls or ceilings, or in attics, crawl spaces, or garages. 7. UTION!: To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models manufactured by iking, model numbers DE900/DE00, E900/E00, OR DE500, E500 or integral blowers manufactured by iking, model numbers DI00, DI440, DI600, DI800, DI00, I00, I600, or I00. NOTE Please refer inside for specific canopy/blower combinations.

3 IMPORTNT Please Read and Follow! W R N I N G To reduce the risk of injury persons in the event of a rangep grease fire, observe the following. (ased on Kitchen Firesafety Tips, published by NFP.). SMOTHER FLMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. E REFUL TO PREENT URNS. If the flames do not go out immediately, EUTE ND LL THE FIRE DEPRTMENT.. NEER PIK UP FLMING PN. You may be burned.. DO NOT USE WTER, including wet dishcloths or wels a violent steam explosion will result. 4. Use an extinguisher ONLY if You know it is a lass extinguisher, and you already know how operate it. The fire is small and contained in the area where it started. The fire department is being called. You can fight the fire with your back an exit. U T I O N For general ventilating use only. Do not use exhaust hazardous or explosive materials and vapors. W R N I N G TO REDUE THE RISK OF FIRE, ELETRIL SHOK, OR INJURY TO PERSONS Rangehoods must be installed with the ventilars that are specified on their carn indicating suitability with this model. Other ventilars cannot be substituted. Dimensions & Specifications (WH 0 H. Wall Hoods w/standard entilar 4, 0, & ) (Hood width) 4 W. -7/8 (60.6 cm) 9-7/8 (76. cm) 5-7/8 (9. cm) (7.6 cm) NOTE: Optional duct cover sold separately. (5. cm) (0.5 cm) 0 (5.4 cm) WH 0 H. Wall Hoods w/standard entilar Description 4 0 Duct cover width -7/8 (60.6 cm) 9-7/8 (75.9 cm) 5-7/8 (9. cm) Duct cover depth Duct cover height (0.5 cm) (0.5 cm) Number of lights Number of filters Heat lamps Interior ventilar kit Interior duct size* N/ 460 FM Standard 7 (7.8 cm) Interior Maximum amps 5.6 * Disregard when using recirculating kits. 460 FM blower is shipped with hood. 4 5

4 learance Dimensions (WH 0 H. Wall Hoods w/standard entilar) Interior entilar Dimensions (WH 0 H. Wall Hoods w/standard entilar) (9.4 cm) 60 min. (5.4 cm) max. (60.0 cm) 4 min. (6.0 cm) 7 max.* (68.6 cm) 4 W. 4 W. 4 W. 4 W. -7/8 (60.6 cm) 9-7/8 (75.9 cm) 5-7/8 (9. cm) 5-/4 (. cm) 8-/4 (0.9 cm) -/4 (8.6 cm) -5/ (0. cm) 4-5/ (7.9 cm) 7-5/ (45.6 cm) D 5/8 (.6 cm) -5/8 (9. cm) 6-5/8 (6.8 cm) 4 (0. cm) 8 (4.6 cm) -4 (.9 cm) 7 (7.8 cm) dia. -7/8 (9.8 cm) D / (. cm) -/ (8.9 cm) Electrical hookup 460 FM Interior entilar Installation * NOTE: When installing with a 4 high-shelf, the 7 (68.6 cm) max. dimensions must be used. 6 7

5 Dimensions & Specifications (WH 8 H. 4 Deep Wall Hoods 4, 0,, 4, 48, 54, 60, & 6) (WH 8 H. 7 Deep Wall Hoods 0,, 4, 48, 54, 60, & 6) learance Dimensions (WH 8 H. Wall Hoods) (Hood width) 4 W. -7/8 (60.6 cm) 9-7/8 (76. cm) 5-7/8 (9. cm) 4 W. 4-7/8 (06.4 cm) 48 W. 47-7/8 (.6 cm) 5-7/8 (6.8 cm) 59-7/8 (5. cm) 65-7/8 (67. cm) (5. cm) (0.5 cm) 8 (45.7 cm) (Hood depth) 4 D. 4 (6.0 cm) 7 D. 7 (68.6 cm) NOTE: Optional duct cover sold separately. WH 8 H. Wall Hoods Description Duct cover width -7/8 (60.6 cm) 9-7/8 (75.9 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 47-7/8 (.6 cm) 5-7/8 (6.8 cm) 59-7/8 (5. cm) 65-7/8 (67. cm) 6min. (67.6 cm) 7 max. (8.9 cm) 0 min. (76. cm) max. (9.4 cm) Duct cover depth (0.5 cm) Duct cover height (0.5 cm) Number of lights 4 4 Number of filters 4 4 (9.4 cm) Heat lamps Interior ventilar kits Exterior ventilar kits IN00/ 600 DE900/ 00* IN00/ 600/00 DE900/ 00* IN00/ 600/00 DE900/ 00* IN600/ 00 DE900/ 00* IN00* IN00* IN00* IN00* DE00*/ 500** DE00*/ 500** DE00*/ 500** DE00*/ 500** In-line ventilar kits DIL900/00 DIL900/00 DIL900/00 DIL900/00 DIL00 DIL00 DIL00 DIL00 Interior duct size 7 (7.8 cm) 7 /0 (7.8/5.4 cm) 7 /0 (7.8/5.4 cm) 7 /0 (7.8/5.4 cm) 0 (5.4 cm) 0 (5.4 cm) 0 (5.4 cm) 0 (5.4 cm) Exterior duct size 0 (5.4 cm) Interior Maximum amps 4.9/ / / Exterior Maximum amps 8.7/ / / / /9. 8.5/9. 8.9/9. 8.9/9. In-Line Maximum amps 6.0/ / / / *,00 FM interior- or exterior-power ventilar should be used when installed over range/rangep with gas char-grill. Max duct run is 50 ft. ** It is recommended that the,500 FM ventilar be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilar kit rating; ll products must be hard wired with - wire with ground. n interior- or exterior-power ventilar kit must be purchased for installation with all 8 H. hoods. 8 9

6 Interior entilar Dimensions (WH 8 H. Wall Hoods) Exterior entilar Dimensions (WH 8 H. Wall Hoods) 4 W. 4 W. -5/ (0. cm) 4-5/ (7.9 cm) 7-5/ (45.6 cm) 0-5/ (5. cm) -5/ (60.8 cm) 6-5/ (68.4 cm) 9-5/ (76.0 cm) -5/ (8.7 cm) 4-5/8 (.7 cm) 8-/4 (47.6 cm) 7 (7.8 cm) dia. 9-/8 (.8 cm) 9-5/8 (4.4 cm) 0 5/8 (.6 cm) 9-/8 (. cm) 4 W. 4 W. -7/8 (60.6 cm) 9-7/8 (75.9 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 47-7/8 (.6 cm) 5-7/8 (6.8 cm) 59-7/8 (5. cm) 65-7/8 (67. cm) 4 W. 4 W. -5/ (0. cm) 4-5/ (7.9 cm) 7-5/ (45.6 cm) 0-5/ (5. cm) -5/ (60.8 cm) 6-5/ (68.4 cm) 9-5/ (76.0 cm) -5/ (8.7 cm) -/ 5-5/ (.7 cm) (5. cm) 9-/4 (4.8 cm) 0 (5.4 cm) dia. 8-/4 (0.9 cm) 6-7/ (6.4 cm) 0 -/ (6.5 cm) (7.6 cm) 4 W. 4 W. -7/8 (60.6 cm) 9-7/8 (75.9 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 47-7/8 (.6 cm) 5-7/8 (6.8 cm) 59-7/8 (5. cm) 65-7/8 (67. cm) 00 or 600 FM Interior entilar Installation for all Wall Hoods 900 or 00 FM Exterior entilar Installation for all Wall Hoods 8-/ (50.0 cm) 9-/8 (.8 cm) 5/8 (.6 cm) 5-5/ (5. cm) 8-/ (0.7 cm) 4 W. 4 W. -5/ (0. cm) 4-5/ (7.9 cm) 7-5/ (45.6 cm) 0-5/ (5. cm) -5/ (60.8 cm) 6-5/ (68.4 cm) 9-5/ (76.0 cm) -5/ (8.7 cm) 5-/ (4.0 cm) 0 (5.4 cm) dia. 0 9-/4 9-/ (.5 cm) (4. cm) 8-/8 (. cm) 4 W. 4 W. -7/8 (60.6 cm) 9-7/8 (75.9 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 47-7/8 (.6 cm) 5-7/8 (6.8 cm) 59-7/8 (5. cm) 65-7/8 (67. cm) 4 W. 4 W. -5/ (0. cm) 4-5/ (7.9 cm) 7-5/ (45.6 cm) 0-5/ (5. cm) -5/ (60.8 cm) 6-5/ (68.4 cm) 9-5/ (76.0 cm) -5/ (8.7 cm) 9-/4 (4.8 cm) 0 (5.4 cm) dia. 0 -/ (6.5 cm) 6-5/8 (6.8 cm) (7.6 cm) 4 W. 4 W. -7/8 (60.6 cm) 9-7/8 (75.9 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 47-7/8 (.6 cm) 5-7/8 (6.8 cm) 59-7/8 (5. cm) 65-7/8 (67. cm) 00 FM Interior entilar Installation for all Wall Hoods 00 or 500 FM Exterior entilar Installation for all Wall Hoods 0

7 Dimensions & Specifications (WH 8 H. T-Series Wall Hoods, 48, & 60 ) learance Dimensions (WH 8 H. T-Series Wall Hoods) Seal joints with silicone. Provided on T Series only. (5. cm) (0.5 cm) 8 (45.7 cm) 8 (45.7 cm) DIM X + 4-/ (.4 cm) (Hood width) 5-7/8 (9. cm) 48 W. 47-7/8 (.6 cm) 59-7/8 (5. cm) 7 (68.6 cm) 6 min. (67.6 cm) 7 max. (8.9 cm) 7 (68.6 cm) 0 min. (76. cm) max. (9.4 cm) NOTE: Optional duct cover sold separately. WH 8 H. T-Series Wall Hoods Description Duct cover width 5-7/8 (9. cm) 47-7/8 (.6 cm) 59-7/8 (5. cm) Duct cover depth (0.5 cm) Duct cover height (0.5 cm) Number of lights 4 Number of filters 4 Interior ventilar kits IN00* IN00* IN00* Exterior ventilar kits DE00*/500** DE00*/500** DE00*/500** In-line ventilar kits DIL00 DIL00 DIL00 Interior duct size 0 (5.4 cm) Exterior duct size 0 (5.4 cm) Interior Maximum amps Exterior Maximum amps 6./ /9. 8.8/9.5 In-Line Maximum amps *,00 FM interior- or exterior-power ventilar should be used with all T-Series models and when indoor models are installed over range/rangep with gas char-grill. Max duct run is 50 ft. ** It is recommended that the,500 FM ventilar be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilar kit rating; ll products must be hard wired with - wire with ground. n interior- or exterior-power ventilar kit must be purchased for installation with all 8 H. hoods. (9.4 cm) Note: T-Series Models must be installed in a covered, non-enclosed area, and should be protected from the elements as much as possible. The botm of the hood should be 0 (76. cm) (9.4 cm) above the grill surface. The hood should be installed 4-/ (.4 cm) plus the distance between the back trim and surface from the back wall. (Note: There is a minimum clearance from the back trim non-combustible surfaces, and a 4 minimum combustible surfaces.) This will require building the hood out from the wall. ny combustible material used for this purpose must be covered with locally-supplied stainless steel. iking also recommends using a backsplash.

8 Dimensions & Specifications (WH himney Wall Hoods 0,, 4, 48, 54, 60, & 6) learance Dimensions (WH himney Wall Hoods) (Duct width) (0.5 cm) (0.5 cm) 4 W. (0.5 cm) 48 W. 8 (45.7 cm) 8 (45.7 cm) 4 (6.0 cm) 4 (6.0 cm) (Hood width) 9-7/8 (76. cm) 5-7/8 (9. cm) 4 W. 4-7/8 (06.4 cm) 48 W. 47-7/8 (.6 cm) 5-7/8 (6.8 cm) 59-7/8 (5. cm) 65-7/8 (67. cm) NOTE: Optional duct cover sold separately. (5. cm) 4 (6.0 cm) WH himney Wall Hoods (0.5 cm) 4 (6.0 cm) 8 (45.7 cm) Description Duct cover width (0.5 cm) (0.5 cm) (0.5 cm) 8 (45.7 cm) 8 (45.7 cm) 4 (6.0 cm) 4 (6.0 cm) Duct cover depth (0.5 cm) Duct cover height (0.5 cm) 4 (6.0 cm) Number of lights 4 4 Number of filters Heat lamps Interior ventilar kits IN00/600 IN00/600 IN600 IN00* IN00* IN00* IN00* Exterior ventilar kits DE900/ 00* DE900/ 00* DE900/ 00* DE00*/ 500** DE00*/ 500** DE00*/ 500** *,00 FM interior- or exterior-power ventilar should be used when installed over range/rangep with gas char-grill. Max duct run is 50 ft. ** It is recommended that the,500 FM ventilar be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilar kit rating; ll products must be hard wired with - wire with ground. n interior- or exterior-power ventilar kit must be purchased for installation with all 8 H. hoods. DE00*/ 500** In-line ventilar kits DIL900/00 DIL900/00 DIL900/00 DIL00 DIL00 DIL00 DIL00 Interior duct size 7 (7.8 cm) 7 (7.8 cm) 7 (7.8 cm) 0 (5.4 cm) 0 (5.4 cm) 0 (5.4 cm) 0 (5.4 cm) Exterior duct size 0 (5.4 cm) Interior Maximum amps 4.9/ / Exterior Maximum amps 8.7/ / / /9. 8.5/9. 8.5/9. 8.5/9. In-Line Maximum amps 6.0/ / / (9.4 cm) 6min. (67.6 cm) 7 max. (8.9 cm) 0 min. (76. cm) max. (9.4 cm) 4 5

9 Interior entilar Dimensions (WH himney Wall Hoods) Exterior entilar Dimensions (WH himney Wall Hoods) (0.5 cm) -/ (.8 cm) 0 power supply (0.5 cm) -/ (.8 cm) 0 power supply 4 W. 4-5/ (7.9 cm) 7-5/ (45.6 cm) 0-5/ (5. cm) 8 (0. cm) -/ (.8 cm) 4 W. 4-5/ (7.9 cm) 7-5/ (45.6 cm) 0-5/ (5. cm) 8 (0. cm) -/ (.8 cm) 4 W. 9-7/8 (75.9 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 7 (7.8 cm) dia. 4 W. 9-7/8 (75.9 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 0 (5.4 cm) dia. 00 or 600 FM Interior entilar Installation for 0,, & 4 models 900 or 00 FM Exterior or In-Line entilar Installation for 0,, & 4 models -/ (.8 cm) 0 power supply -/ (.8 cm) 0 power supply -5/ (60.8 cm) 6-5/ (68.4 cm) 9-5/ (76.0 cm) -5/ (8.7 cm) (5. cm) -/ (.8 cm) 8 (45.7 cm) 8 (45.7 cm) 4 (6.0 cm) 4 (6.0 cm) -5/ (60.8 cm) 6-5/ (68.4 cm) 9-5/ (76.0 cm) -5/ (8.7 cm) (5. cm) -/ (.8 cm) 8 (45.7 cm) 8 (45.7 cm) 4 (6.0 cm) 4 (6.0 cm) 47-7/8 (.6 cm) 5-7/8 (6.8 cm) 59-7/8 (5. cm) 65-7/8 (67. cm) 0 (5.4 cm) dia. 47-7/8 (.6 cm) 5-7/8 (6.8 cm) 59-7/8 (5. cm) 65-7/8 (67. cm) 0 (5.4 cm) dia. 00 FM Interior entilar Installation for 48, 54, 60, & 6 models 900, 00 or 500 FM Exterior or In-Line entilar Installation for 48, 54, 60, & 6 models 6 7

10 Dimensions & Specifications (IH Island Hoods, 4, 54, & 6) learance Dimensions (IH Island Hoods) (5. cm) (0.5 cm) 8 (45.7 cm) (Hood width) 5-7/8 (9. cm) 4 W. 4-7/8 (06.4 cm) 5-7/8 (6.8 cm) 65-7/8 (67. cm) NOTE: Optional duct cover sold separately. 0 (76. cm) 6min. (67.6 cm) 7 max. (8.9 cm) 0 min. (76. cm) IH Island Hoods Description Duct cover width 5-7/8 (9. cm) 4-7/8 (06.4 cm) 5-7/8 (6.8 cm) 65-7/8 (67. cm) Duct cover depth (0.5 cm) Duct cover height (0.5 cm) Number of lights (9.4 cm) max. (9.4 cm) Number of filters Heat lamps N/ Interior ventilar kits IN600/00* IN600/00* IN00* IN00* Exterior ventilar kits DE900/00* DE900/00*/500** DE00*/500** DE00*/500** In-line ventilar kits DIL900/00 DIL900/00 DIL00 DIL00 Interior duct size 7 (7.8 cm)/ 0 (5.4 cm) 7 (7.8 cm)/ 0 (5.4 cm) 0 (5.4 cm) 0 (5.4 cm) Exterior duct size 0 (5.4 cm) Interior Maximum amps 4.6/ / Exterior Maximum amps 7.4/ /4.7/ /6. 6./7. In-Line Maximum amps 4.7/ / *,00 FM interior- or exterior-power ventilar should be used when installed over range/rangep with gas char-grill. Max duct run is 50 ft. ** It is recommended that the,500 FM ventilar be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilar kit rating; ll products must be hard wired with - wire with ground. n interior- or exterior-power ventilar kit must be purchased for installation with all 8 H. hoods. 8 9

11 Interior entilar Dimensions (IH Island Hoods) Exterior entilar Dimensions (IH Island Hoods) 4 W. 4 W. 7-5/ (45.6 cm) 0-5/ (8. cm) 6-5/ (68.4 cm) -5/ (8.7 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 5-7/8 (6.8 cm) 65-7/8 (67. cm) 4-5/8 (.7 cm) 7 (7.8 cm) dia. 8-/4 (47.6 cm) 9-/8 (.8 cm) 0 9-5/8 (4.4 cm) 5/8 (.6 cm) 9-/8 (. cm) 4 W. 4 W. 7-5/ (45.6 cm) 0-5/ (8. cm) 6-5/ (68.4 cm) -5/ (8.7 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 5-7/8 (6.8 cm) 65-7/8 (67. cm) 5-5/ (5. cm) 9-/4 (4.8 cm) -/ (.7 cm) 0 (5.4 cm) dia. 8-/4 (0.9 cm) 0 6-7/ (6.4 cm) -/ (6.5 cm) (7.6 cm) 600 FM Interior entilar Installation for all Island Hoods 900 or 00 FM Exterior or In-Line entilar Installation for all Island Hoods 4 W. 4 W. 7-5/ (45.6 cm) 0-5/ (8. cm) 6-5/ (68.4 cm) -5/ (8.7 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 5-7/8 (6.8 cm) 65-7/8 (67. cm) 8-/8 (50.0 cm) 5-/ (4 cm) 8-/8 (. cm) 0 0 (5.4 cm) dia. 9-/4 (.5 cm) 9-/8 (.8 cm) 9-/ (4. cm) 8-/4 (47.6 cm) 4 W. 4 W. 7-5/ (45.6 cm) 0-5/ (8. cm) 6-5/ (68.4 cm) -5/ (8.7 cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) 5-7/8 (6.8 cm) 65-7/8 (67. cm) 5-5/ (5. cm) 9-/4 (4.8 cm) 0 (5.4 cm) dia. 8-/ (0.7 cm) 0 -/ (6.5 cm) 6-5/8 (6.5 cm) (7.6 cm) 00 FM Interior entilar Installation for all Island Hoods 900, 00 or 500 FM Exterior or In-Line entilar Installation for all Island Hoods 0

12 Dimensions & Specifications (IH himney Island Hoods, 4, 54, & 6) learance Dimensions (IH himney Island Hoods) 4 W. (Duct width) (0.5 cm) (0.5 cm) 8 (45.7 cm) 4 (70.0 cm) 4 W. (Duct height) (0.5 cm) or 4 (6.0 cm) or (9.4 cm) 6 (5. cm) 8 (45.7 cm) (Hood width) 5-7/8 (9. cm) 4 W. 4-7/8 (06.4 cm) 5-7/8 (6.8 cm) 65-7/8 (67. cm) NOTE: Optional duct cover sold separately. 0 (76. cm) IH himney Island Hoods Description Duct cover width (0.5 cm) (0.5 cm) 8 (45.7 cm) 4 (70.0 cm) Duct cover depth (0.5 cm) Duct cover height (0.5 cm) or 4 (6.0 cm) or (9.4 cm) Number of lights (9.4 cm) 6min. (67.6 cm) 7 max. (8.9 cm) 0 min. (76. cm) max. (9.4 cm) Number of filters Heat lamps N/ Interior ventilar kits IN600 IN600 IN00* IN00* Exterior ventilar kits DE900/00* DE900/00*/500** DE00*/500** DE00*/500** In-line ventilar kits DIL900/00 DIL900/00 DIL00 DIL00 Interior duct size 7 (7.8 cm) 7 (7.8 cm) 0 (5.4 cm) 0 (5.4 cm) Exterior duct size 0 (5.4 cm) Interior Maximum amps Exterior Maximum amps 7.4/ /4.7/ / /7.4 In-Line Maximum amps 4.7/6.5.9/ *,00 FM interior- or exterior-power ventilar should be used when installed over range/rangep with gas char-grill. Max duct run is 50 ft. ** It is recommended that the,500 FM ventilar be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilar kit rating; ll products must be hard wired with - wire with ground. n interior or exterior-power ventilar kit must be purchased for installation with all 8 H. hoods.

13 Interior entilar Dimensions (IH himney Island Hoods) Exterior entilar Dimensions (IH himney Island Hoods) (0.5 cm) -/8 (.9 cm) (0.5 cm) -/8 (.9 cm) 4 W. 4 W. 7-5/ (45.6 cm) 0-5/ (5. cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) (5. cm) 0 power supply -/8 (.9 cm) 4 W. 4 W. 7-5/ (45.6 cm) 0-5/ (5. cm) 5-7/8 (9. cm) 4-7/8 (06.4 cm) (5. cm) 0 power supply -/8 (.9 cm) 7 (7.8 cm) dia. 0 (5.4 cm) dia. 600 FM Interior entilar Installation for all himney Island Hoods 900 or 00 FM Exterior or In-Line entilar Installation for all himney Island Hoods 6-5/ (68.4 cm) -5/ (8.7 cm) 5-7/8 (6.8 cm) 65-7/8 (67. cm) 8 (45.7 cm) 4 (6.0 cm) (5. cm) 0 (5.4 cm) dia. -/8 (.9 cm) 0 power supply -/8 (.9 cm) 6-5/ (68.4 cm) -5/ (8.7 cm) 5-7/8 (6.8 cm) 65-7/8 (67. cm) 8 (45.7 cm) 4 (6.0 cm) (5. cm) 0 (5.4 cm) dia. -/8 (.9 cm) 0 power supply -/8 (.9 cm) 00 FM Interior entilar Installation for all himney Island Hoods 900, 00 or 500 FM Exterior or In-Line entilar Installation for all himney Island Hoods 4 5

14 Dimensions & Specifications ( Wall usm entilar System 0,, 4, 48, 54, 60 & 6) * Installing Hood anopy (usm Hood anopy uuts) *For best results, center the unit over the burners of the cooking product (front back; right left). * Make sure the back wall of the cusm hood canopy is flush with the cuut so the ventilar system may be mounted as shown on page 5. usm Hood anopy otm uut Dimensions Wall Hoods Description (Hood Width) (Hood Depth) 0 W. 7-7/ (69.7 cm) -7/ (54.5 cm) W. -7/ (84.9 cm) -7/ (54.5 cm) 4 W. 9-7/ (00. cm) -7/ (54.5 cm) 48 W. 45-7/ (5.4 cm) -7/ (54.5 cm) 54 W. 5-7/ (0.7 cm) -7/ (54.5 cm) 60 W. 57-7/ (45.9 cm) -7/ (54.5 cm) 6 W. 6-7/ (6. cm) -7/ (54.5 cm) Wall usm entilar System Description Number of lights 4 4 Number of filters 4 4 Heat lamps Interior ventilar kits IN00/ 600/00* IN00/ 600/00* IN600/ 00* IN00* IN00* IN00* IN00* Exterior ventilar kits DE900/ 00* DE900/ 00* DE900/ 00* DE00*/ 500** DE00*/ 500** DE00*/ 500** DE00*/ 500** In-line ventilar kits DIL900/00 DIL900/00 DIL900/00 DIL00 DIL00 DIL00 DIL00 Interior duct size 7 /0 (7.8/5.4 cm) 7 /0 (7.8/5.4 cm) 7 /0 (7.8/5.4 cm) 0 (5.4 cm) 0 (5.4 cm) 0 (5.4 cm) 0 (5.4 cm) Exterior duct size 0 (5.4 cm) Interior Maximum amps 5.9/ / / Exterior Maximum amps 8.7/ / / /9. 8.5/9. 8.9/9. 8.9/9. In-Line Maximum amps 6.0/ / / *,00 FM interior- or exterior-power ventilar should be used when installed over range/rangep with gas char-grill. Max duct run is 50 ft. ** It is recommended that the,500 FM ventilar be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilar kit rating; ll products must be hard wired with - wire with ground. n interior- or exterior-power ventilar kit must be purchased for installation with all 8 H. hoods. ) Position ventilar system inside of the cusm hood canopy and center it front back and left right. ) otm mounting holes fasten ventilar system botm of cusm hood canopy with the screws provided. uilt-in entilar System ) OPTIONL Rear mounting holes fasten ventilar system rear of cusm hood canopy. 6 7

15 learance Dimensions ( Wall usm entilar System) uilt-in Wall usm entilar System Dimensions ( Models) -/ (.8 cm) (.54 cm) -/ (.8 cm) 7/8 (. cm) (usm Hood) -/ (9. cm) 7-/4 (4.8 cm) 5/8 (.6 cm) (5. cm) 5/8 (.6 cm) (9.4 cm) 6min. (67.6 cm) 7 max. (8.9 cm) 0 min. (76. cm) max. (9.4 cm) 5-/ (4.0 cm) -7/8 (55.8 cm) For 900, 00 or 500 FM Exterior or In-Line entilar Installation 0 (5.4 cm) dia. 8-/4 (0.9 cm) D (5. cm) 4-5/8 (.7 cm) -7/8 (55.8 cm) For 00, 600 or 00 FM Interior entilar Installation 9-/8 (.8 cm) 0 7 (7.6 cm) 0 (7.8 cm) dia. duct location 9-5/8 (4.4 cm) -/ (6.4 cm) 8-/4 (47.6 cm) D 9-/4 (.5 cm) 5/8 (.6 cm) 5/8 (.6 cm) 900 or 00 FM Exterior or In-Line entilar Installation 0,, 4 W. Models 00 or 600 FM Interior entilar Installation 0,, 4 W. Models *Note: Dotted Line (...) represents cuut. 0 W. 8-/4 (7.8 cm) W. 4-/4 (87.0 cm) 4 W. 40-/4 (0. cm) D 0 W. 4-/8 (5.9 cm) W. 7-/8 (4.5 cm) 4 W. 0-/8 (5. cm) 8 9

16 uilt-in Wall usm entilar System Dimensions ( Models) Dimensions & Specifications (I Island usm entilar System, 4, 54 & 6) 8-/4 (0.9 cm) D * 5-/ (4.0 cm) (5. cm) 0 (5.4 cm) dia. 5/8 (.6 cm) 0 (7.6 cm) -/ (6.4 cm) *For best results, center the unit over the burners of the cooking product (front back; right left). * Make sure the back wall of the cusm hood canopy is flush with the cuut so the ventilar system may be mounted as shown on page or 500 FM Exterior or In-Line entilar Installation 48, 54, 60, 6 W. Models otm uut Dimensions 5-/ (4.0 cm) 0 (5.4 cm) dia. duct location 5/8 (.6 cm) 8-/ (50.0 cm) 9-/4 (.5 cm) 9-/8 (.8 cm) 0 9-/ (4.4 cm) D 8-/8 (. cm) Island Hoods Description (Hood Width) (Hood Depth) W. -7/ (84.9 cm) 7-9/ (70.0 cm) 4 W. 9-7/ (00. cm) 7-9/ (70.0 cm) 54 W. 5-7/ (0.7 cm) 7-9/ (70.0 cm) 6 W. 6-7/ (6. cm) 7-9/ (70.0 cm) I Island usm entilar System Description Number of lights Number of filters FM Interior entilar Installation 0,, 4, 48, 54, 60, 6 W. Models *Note: Dotted Line (...) represents cuut. Heat lamps N/ Interior ventilar kits IN600/00* IN600/00* IN00* IN00* Exterior ventilar kits DE900/00* DE900/00*/500** DE00*/500** DE00*/500** In-line ventilar kits DIL900/00 DIL900/00 DIL00 DIL00 Interior duct size 7 (7.8 cm)/ 7 (7.8 cm)/ 0 (5.4 cm) 0 (5.4 cm) 0 (5.4 cm) 0 (5.4 cm) 0 W. 8-/4 (7.8 cm) W. 4-/4 (87.0 cm) 4 W. 40-/4 (0. cm) 48 W. 46-/4 (7.5 cm) 54 W. 5-/4 (.7 cm) 60 W. 58-/4 (48.0 cm) 6 W. 64-/4 (6. cm) D 0 W. 4-/8 (5.9 cm) W. 7-/8 (4.5 cm) 4 W. 0-/8 (5. cm) 48 W. -/8 (58.7 cm) 54 W. 6-/8 (66.4 cm) 60 W. 9-/8 (74.0 cm) 6 W. -/8 (8.6 cm) Exterior duct size 0 (5.4 cm) Interior Maximum amps 4.6/ / Exterior Maximum amps 7.4/ /4.8/ /6. 5.6/6. In-Line Maximum amps 4.7/ / *,00 FM interior- or exterior-power ventilar should be used when installed over range/rangep with gas char-grill. Max duct run is 50 ft. ** It is recommended that the,500 FM ventilar be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilar kit rating; ll products must be hard wired with - wire with ground. n interior- or exterior-power ventilar kit must be purchased for installation with all 8 H. hoods. 0

17 Installing Hood anopy (usm Hood anopy uuts) learance Dimensions (I Island usm entilar System) usm Hood anopy (usm Hood) 6min. (67.6 cm) 7 max. (8.9 cm) 0 min. (76. cm) ) Position ventilar system inside of the cusm hood canopy and center it front back and left right. ) otm mounting holes fasten ventilar system botm of cusm hood canopy with the screws provided. uilt-in entilar System (9.4 cm) max. (9.4 cm) ) OPTIONL Rear mounting holes fasten ventilar system rear of cusm hood canopy.

18 uilt-in Island usm entilar System Dimensions (I Models) uilt-in Island usm entilar System Dimensions (I Models) -/ (.8 cm) (.5 cm) -/ (.8 cm) / (.7 cm) 8-/4 (47.6 cm) 5/8 (.6 cm) -/ (9. cm) 7-7/ (69.7 cm) (including screw heads) 8-7/ (7. cm) External Power (5. cm) 5/8 (.6 cm) -/ (9. cm) 7-7/ (69.7 cm) (including screw heads) 8-7/ (7. cm) Internal Power 7-/4 (4.8 cm) 5-/4 (4.6 cm) 0 (5.4 cm) dia. 5/8 (.6 cm) 8-/4 (.0 cm) 0 -/ (6.4 cm) (5. cm) (7.6 cm) 900, 00 or 500 External or In-Line Power 4, 54, 6 W. Models 5-/ (4.0 cm) 0 (5.4 cm) dia. duct location 5/8 (.6 cm) 9-/4 (.5 cm) 0 9-/ (4.4 cm) 8-/4 (47.6 cm) 00 FM Internal Power 4, 54, 6 W. Models 7/8 (. cm) 8-/8 (. cm) 5-/4 (4.6 cm) 8-/4 (.0 cm) 0 (5. cm) (7.6 cm) -/ (.0 cm) 5-/ (. cm) 8-/4 (47.6 cm) 9-/8 (.8 cm) 0 9-/4 (.5 cm) 54 W. 5-/4 (.7 cm) 6 W. 64-/4 (6. cm) *Note: Dotted Line (...) represents cuut. 54 W. 6-/8 (66.4 cm) 6 W. -/8 (8.6 cm) 0 (5.4 cm) dia. -/ (6.4 cm) 7 (7.8 cm) dia. 9-5/8 (4.4 cm) 5/8 (.6 cm) 900 or 00 FM External or In-Line Power, 4 W. Models W. 4-/4 (87.0 cm) 4 W. 40-/4 (0. cm) 5/8 (.6 cm) 600 FM Internal Power, 4 W. Models *Note: Dotted Line (...) represents cuut. W. 7-/8 (4.5 cm) 4 W. 0-/8 (5. cm) 4 5

19 Planning Information Installation (WH 0 H. Wall Hoods w/standard entilar) Proper installation of ducting is extremely important ensure maximum performance from any ventilation product. ll FMs are based on tests at 0. static pressure: without applying static pressure, FM would be greatly overstated. Straight runs and gradual turns are best; for example, each 90º elbow is equivalent 5-0 feet ( cm) of straight run. Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance. Proper performance is dependent on proper ducting; make sure that a qualified and trained installer is used. heck with a qualified and trained installer or local codes for makeup air requirement, if any. Max. amp rating for hoods includes recommended ventilar kit rating; all products must be hard wired direct with -wire with ground. Roof cap 7 round duct Roof cap 0 round duct 00 or 600 FM single blower interior-power typical ductwork Duct cover or soffit Hood 00 FM single blower interior power typical ductwork Duct cover or soffit 4 5/ nut driver heck damper for unrestricted movement, adjust if necessary. ttach transition damper. Seal with aluminum tape. W R N I N G To reduce the risk of fire, electric shock, or injury persons, observe the following: Plan where the duct work will be located. Install proper-sized duct work, and roof or wall cap for the type of blower you are using. Recommended hood locations for the most common installations are shown. djust your measurements for various heights of ceilings, soffits, cabinets, or ranges/rangeps. heck Framing Exterior blower 0 round duct Hood 900, 00, or 500 FM exterior power typical ductwork Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. efore servicing or cleaning unit, switch power off at service panel and lock service panel prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, the service panel. Duct cover or soffit Flip hood over and remove electrical box cover. Hood Wall cap Wall Installation exterior power typical ductwork 4 5 Duct Duct cover or soffit Hood NOTE: ecause of the weight of the hood make sure that the mounting screws are driven in the framing and not just the drywall. It may be necessary drill additional holes in the canopy for proper alignment. NOTE: Wall exhaust must be a minimum of 4 (6.0 cm) from ground. This may vary depending on local codes and geographic location. Electrical Supply Run 0 electrical wiring from service panel installation location. See Specifications pages for the maximum amp requirements. Insert of electrical wiring through the p of vent hood and secure using wiring restrain. Refer local codes. Slide duct over transition and tape around joint. 6 7

20 6 5/ nut driver 5/ nut driver UTION: Secure vent hood wall using screws provided. Use additional mounting screws and wall anchors, if necessary. 7 RE OR GREEN UTION: If not using a duct cover, using screws provided, make sure p mounting screws are secured in soffit or cabinet framing. Use additional mounting screws, if necessary. 8 Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Duct over Option (WH 0 H. Wall Hoods w/standard entilar) WHITE GREEN LK WHITE LK onnect black black, white white, and the green/bare wire under the green screw. NOTE: Housing wiring must be properly installed for wiring be correct when wiring unit. Replace electrical box cover. Make connection breaker box. Measure distance from ceiling canopy. Installation (WH 0 H. Wall Hoods w/recirculating Kit) Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. 9 0 Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood upside down on recirculating unit. 8 9

21 4 8 RE OR GREEN 9 WHITE GREEN LK WHITE LK ttach with screws and lock washers provided. ttach with screws. onnect black black, white white, and the green/bare wire under the green screw. NOTE: Housing wiring must be properly installed for wiring be correct when wiring unit. Replace electrical box cover. Make connection breaker box. 5 W R N I N G To reduce the risk of fire, electric shock, or injury persons, observe the following: 0 Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. efore servicing or cleaning unit, switch power off at service panel and lock service panel prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, the service panel. Remove electrical box cover. ssemble brackets baffles and insert charcoal filters. Slide filter front over front lip. Push filter rear up, then slide back over rear lip / nut driver Flip hood over. Insert of electrical wiring through the p of vent hood and secure. Refer local codes. UTION: Secure vent hood. Make sure mounting screws are secured in framing. Use additional mounting screws and wall anchors, if necessary. Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. Slide filter front over front lip. Push filter rear up, then slide back over rear lip. 40 4

22 Installation (WH 8 H. Wall & WH himney Wall Hoods) -/ x /4 (.8 cm) x (.9 cm) wood strip -/ (4.6 cm) 5/ nut driver Slot for wood strip 5/ nut driver 5 6 Measure down -/6 (4.6 cm) from desired height of hood and secure -/ x /4 wood strip (provided locally) wall using screws provided. 5/ nut driver Use additional mounting screws secure hood wood strip. 5/ nut driver Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. Duct over Option (WH 8 H. Wall Hoods) Slide filter front over front lip. Push filter rear up, then slide back over rear lip. UTION: Secure vent hood wall using screws provided. Use additional mounting screws and wall anchors, if necessary. UTION: If not using a duct cover, using screws provided, make sure p mounting screws are secured in soffit or cabinet framing use additional mounting screws, if necessary. Measure distance from ceiling canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. 4 To install ventillation kit refer ventillation kit installation instructions. Slide filter front over front lip. Push filter rear up, then slide back over rear lip. 4 4

23 Duct over Option (WH himney Wall Hoods) Installation (IH/IH Island Hoods) Measure distance from ceiling canopy. Tape avoid scratching. heck framing where cuut will be. NOTE: 00 lb. limit. ut appropriate size hole in ceiling. Either 7 or 0 depending on your specific unit and ventillar kit. 4 Mounting options: Using duct cover with ceiling mounting bracket. (Option - IH only) Using threaded rod for additional support. (Option ) ttaching hood directly soffit or duct cover. (Skip step ) Place duct cover p inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts fasten in place and remove tape. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. ttach duct cover optional ceiling mounting bracket. 5/ nut driver ttach duct cover ceiling. The ceiling bracket can be hidden by using a locally supplied trim. dditional support option. Drill holes in all four corners for threaded rod and run rods from hood ceiling

24 4 5/ nut driver Service & Registration Service & Parts Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. ll other servicing should be referred a qualified technician. Run duct work down botm edge of duct cover/soffit and secure in place. Make sure the duct does not stick down past the cover. To install ventillation kit refer ventillation kit installation instructions. ttach canopy duct cover/soffit. Seal p of hood duct with aluminum tape. 5 Record the following information indicated below. You will need it if service is ever required. The serial number and model number for your appliance are located on the identification plate mounted on the inside of the hood canopy. Model number Serial number Date of purchase Slide filter front over front lip. Push filter rear up, then slide back over rear lip. 6 7 Date installed Dealer's name ddress Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. NOTE: Number of spacers and baffles may vary by model. Slide filter front over front lip. Push filter rear up, then slide back over rear lip

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662) Installation Guide Viking Range, LL Front Street Greenwood, Mississippi 890 US (66) 455-00 For product information, call -888-(845-464) or visit the Viking Web site at vikingrange.com Professional Indoor

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range orporation Front Street Greenwood, Mississippi 890 US (66) 455-00 For product information, call -888-VIKING (845-464) or visit the Viking Web site at vikingrange.com

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation Front Street Greenwood, Mississippi 890 US (66) 455-00 For product information, call -888-VIKING (845-464) or visit the Viking Web site at vikingrange.com

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation Front Street Greenwood, Mississippi 890 US (66) 455-00 For product information, call -888-VIKING (845-464) or visit the Viking Web site at vikingrange.com

More information

Installation. Professional Indoor & Outdoor Hoods

Installation. Professional Indoor & Outdoor Hoods Installation Professional Indoor & Outdoor Hoods VWH53012 / CVWH53012 / VWH53612 / CVWH53612 VWH53048 / CVWH53048 / VWH53648 / CVWH53648 / VWH54248 / CVWH54248 / VWH54848 / CVWH54848 / VWH56048 / CVWH56048

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ProLine Range Hoods Installation Guide Built-In Interior Power 8 Height Range Hoods ProLine Range Hoods, LLC 750 South 500 West, Suite 00 Salt Lake City, UTAH 845 USA www.prolinehoods.com INSTALLATION

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Professional Series Built-In Chimney-Style Hoods Viking Range Corporation 111 Front Street Greenwood, MIssissippi 38930 USA NOTE: IF INSTALLING HOOD WITH WARMING SHELF PANEL,

More information

Installation GUIDE. 5 SERIES Professional Indoor Hoods EVWH53048, EVWH53648, EVWH54848

Installation GUIDE. 5 SERIES Professional Indoor Hoods EVWH53048, EVWH53648, EVWH54848 Installation GUIDE 5 SERIES Professional Indoor Hoods EVWH53048, EVWH53648, EVWH54848 Table of Contents Contenido Table of Contents... 1 IMPORTANT Please Read and Follow... 2 Dimensions & Specifications...

More information

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods HEIGHT OF HOOD The bottom of the hood to should be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (182.9 cm) above the

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide uilt-in 18 H. Hoods (Indoor and Outdoor Models) NOTE: IF INSTLLING HOOD WITH WRMING SHELF PNEL, INSTLL WRMING SHELF PNEL FIRST. IMPORTNT - PLESE RED ND SVE THESE INSTRUTIONS efore

More information

WhispAire Range Hood Quiet Hood

WhispAire Range Hood Quiet Hood INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS WhispAire Range Hood Quiet Hood IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF FIRE, ELEC- TRIC SHOCK, OR INJURY TO PERSONS, OBSERVE

More information

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48 Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36 Models ZV671WSS, ZV681YSS GE Monogram Installation Instructions Professional Vent Hoods 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS 36" Models ZV671WSS, ZV681YSS ZV670WSS, ZV680YSS 30" Models ZV370YSS, ZV371YSS CAUTION WARNING

More information

Pro Island Ventilation Hoods

Pro Island Ventilation Hoods INSTALLATION GUIDE Pro Island Ventilation Hoods READ AND SAVE THESE INSTRUCTIONS Contents Wolf Pro Island Ventilation Hoods................. 3 Safety Instructions............................ 4 Installation

More information

NUTONE RANGE HOOD NTM SERIES

NUTONE RANGE HOOD NTM SERIES INSTALLATION INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS HB0043 NUTONE RANGE HOOD NTM SERIES IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC

More information

Hood. warning. warning. caution

Hood. warning. warning. caution Range Hood To register this product, visit: www.broan.com model QB130SS read and save these instructions for domestic cooking only Page 1 warning TO REDUCE THE RISK OF Fire, ELECTRIC SHocK, OR injury TO

More information

ISLAND INSTALLATION WALL INSTALLATION

ISLAND INSTALLATION WALL INSTALLATION HEIGHT OF HOOD The bottom of the hood should be 30 (76.2 cm) min. to 36 (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (175.3 cm) above

More information

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation

More information

WhispAire Range Hood Quiet Hood

WhispAire Range Hood Quiet Hood INSTALLATION INSTRUCTIONS WhispAire Range Hood Quiet Hood READ & SAVE THESE INTRUCTIONS WA6500 SERIES QT20000 SERIES IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,

More information

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING -

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS Use and Care of Recirculation Hood Model JN327 and Ventilating Hood Models JV327, JV337 & JV347 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC

More information

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD

More information

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

! FOR DOMESTIC COOKING ONLY!

! FOR DOMESTIC COOKING ONLY! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer

More information

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD

More information

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES

More information

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu Installation Manual RANGE HOOD MODEL: BUF-07W BUF-07P BUF-07W/P TABLE OF CONTENTS Safety Instructions... 2, 3 Name of Parts... 4 Circuit Diagram... 4 Dimensions/Accessories... 5, 6 Range Hood Location...

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL AB Series Range Hood READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT

More information

o Brass Trim Option (BR) nameplate,

o Brass Trim Option (BR) nameplate, Standard Features & Accessories VENTILATION Built-In 10 H. Wall Hood w/ventilar/ 12 H. Chimney Wall Hood w/ventilar/ All models include Heavy-duty construction o Virtually seamless stainless steel design

More information

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

DCWL Designer Chimney Wall Hood w/ledge*

DCWL Designer Chimney Wall Hood w/ledge* Standard Features & Accessories All models include Adjustable duct cover (for 8 9 ceilings) is standard Must also purchase interior, exterior or in-line ventilar kit, sold separately (see Installation

More information

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation

More information

VENTILATION. Standard Features & Accessories. Model Options. Designer Built-In Wall Hoods

VENTILATION. Standard Features & Accessories. Model Options. Designer Built-In Wall Hoods Standard Features & Accessories All models include Must also purchase interior or exterior ventilar kit, sold separately (see Installation Notes & Accessories for recommended Viking ventilar products 24

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning

More information

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento. Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento Ceiling Hood Models SUT950 SUT951 *** BEFORE INSTALLATION *** ENSURE THERE IS

More information

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number: brisas by Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number: SEP08.0101 Zephyr Corporation SAFETY NOTICE... 2-3 LIST OF MATERIALS...

More information

! FOR DOMESTIC COOKING ONLY!!

! FOR DOMESTIC COOKING ONLY!! ALLURE WS3 SERIES ALLURE WS3 SERIES READ AND SAVE THESE INSTRUCTIONS! FOR DOMESTIC COOKING ONLY!! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use

More information

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and

More information

Installation Instructions

Installation Instructions Installation Instructions Speedcook Oven Read carefully. Keep these Instructions. INSTALLATION INSTRUCTIONS Electrical Requirements Product rating is 240/208 volts AC, 60 Hertz, 30 amps and 6.5 kilowatts.

More information

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st Venting Methods This range hood is factory set for venting through the roof or wall. For non-vented (re-circulating) installations, see Ductless Conversion on Page 7. Vent work can terminate either through

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS Use and Care of Recirculation Hood Model JN322 and Ventilating Hood Models JV322, JV332 & JV346 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC

More information

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL. ***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL. Revised 6/11/18 Copyright 2018 Trade-Wind Manufacturing, LLC Proverbs 22:29 Page 1 Revised 6/11/18 Copyright

More information

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027 Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL...28 BEST BY BROAN, P. O. Box 140, Hartford, WI 53027 99043487A READ AND SAVE THESE INSTRUCTIONS INTENDED FOR DOMESTIC COOKING ONLY!! WARNING TO REDUCE THE

More information

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL. ***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL. Revised 6/11/18 Copyright 2018 Trade-Wind Manufacturing, LLC Proverbs 22:29 Page 1 Revised 6/11/18 Copyright

More information

! FOR DOMESTIC COOKING ONLY!

! FOR DOMESTIC COOKING ONLY! MODEL 103023 WOOD HOOD KIT READ AND SAVE THESE INSTRUCTIONS! FOR DOMESTIC COOKING ONLY! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit

More information

Designer Wall Range Hood Installation. Installation Tutorial Video

Designer Wall Range Hood Installation. Installation Tutorial Video Designer Wall Range Hood Installation Installation Tutorial Video 9 Designer Wall Range Hood Installation Please unpack your range hood when it is delivered and inspect to ensure all parts are included.

More information

All (-4) Models 390CFM Code Compliant

All (-4) Models 390CFM Code Compliant INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Designer Series Liners Designer Series Models Model Width CFM Type of Motor & Blower VSL430 BF 28 3/8 * Remote VSL436 BF 34-3/8 * Remote VSL442 BF

More information

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation. INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Designer Series Liners Designer Series Models 22 Depth Model Width CFM Type of Motor & Blower VSL436-0-22 BF 34 3/ 8 * Remote VSL442-0-22 BF 40 3/

More information

Type of Motor & Blower

Type of Motor & Blower 1 INSTALLATION INSTRUCTIONS & USE & CARE GUIDE PMB Series Models PMB Series Models Model PMB02 PMB03 * PMB06 Width & Depth 22 x 12 22 x 12 22 x 12 CFM 240 390 600 Type of Motor & Blower Internal Internal

More information

www. TheRangeHoodStore.com

www. TheRangeHoodStore.com Two Locations 916 Delaware Avenue Marysville, Ohio 43040 984 East Greg Street Sparks, Nevada 89431-6521 www.zlinekitchen.com www. TheRangeHoodStore.com Table of Contents Installation for: Walls... Designer

More information

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range Electrical Requirements IMPORTANT: Observe all governing codes and ordinances. (Please consult with a qualified electrician for 220-Volt 50 Hz voltage) It is the customer s responsibility: To contact a

More information

Installation Instructions

Installation Instructions Installation Instructions Over The Range Microwave Oven BEFORE YOU BEGIN (Read these instructions completely and carefully.) IMPORTANT IMPORTANT Save these instructions for local inspector s use. Observe

More information

User s Manual Metro/ Legend Residential Wall Mount Hood. Models: 3410 Legend 36 Hood 900 cfm 3415 Metro 36 Hood 900 cfm

User s Manual Metro/ Legend Residential Wall Mount Hood. Models: 3410 Legend 36 Hood 900 cfm 3415 Metro 36 Hood 900 cfm User s Manual Metro/ Legend Residential Wall Mount Hood Legend 3400 Legend 30 Hood 500 cfm 3405 Metro 30 Hood 500 cfm Models: 3410 Legend 36 Hood 900 cfm 3415 Metro 36 Hood 900 cfm 3420 Legend 42 Hood

More information

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25 ON/OFF Professional hoods 48", 36" and 30" restaurant-style hoods 48", 36" and 30" tapered-sided hoods 48", 36" and 30" straight-sided hoods 30" under-cabinet hood ZV48RSFSS, ZV36RSFSS and ZV30RSFSS ZV48TSFSS,

More information

INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS

INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS INSTLLTION INSTRUTIONS FRSTNING LTRI RNG WITH OUL OVNS Table of ontents RNG SFTY... 1 INSTLLTION RQUIRMNTS... 2 Tools and Parts... 2 Location Requirements... 2 lectrical Requirements... 4 INSTLLTION INSTRUTIONS...

More information

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

Connection Diagrams (36 - 48 Widths) Wall Side 1 ¾. Connection Diagram (48 - 60 Widths) (Front View) Connection Diagram (54 - 66 Widths) R DESIGNER SERIES WALL MOUNT RANGE HOOD JPH/C2 Series Equipped with LED lighting. Not available with heat lamps. Optional duct covers available in standard and custom sizes. Recommended Mounting Height

More information

Use, Care, and Installation Guide

Use, Care, and Installation Guide Use, Care, and Installation Guide Summit vsu-e30as vsu-e36as Model number: Serial Number: Plateau vpl-e30as vpl-e36as crescent vcr-e30ag vcr-e36ag OCT10.0301 SAFETY NOTICE... 2-3 LIST OF MATERIALS...

More information

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

CONTENTS DESCRIPTION UNPACKING DIMENSIONS INSTALLATION INSTRUCTIONS Recessed Luminaire ModelNo.FV-NLF6RES CONTENTS GENERAL SAFETY INFORMATION DESCRIPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM INSTALLATION (BETWEEN JOISTS MOUNTING)

More information

Use, Care, and Installation Guide

Use, Care, and Installation Guide Use, Care, and Installation Guide Tornado II AK8200AS Tornado III AK8300ASX Model number: Serial Number: Date of Purchase: Sales Dealer: JAN08.0301 2008 Zephyr Corporation READ AND SAVE THESE INSTRUCTIONS

More information

Wall Mount Chimney Style. Island Mount Chimney Style. Wall Mount Professional Style. Insert Mount Professional Style

Wall Mount Chimney Style. Island Mount Chimney Style. Wall Mount Professional Style. Insert Mount Professional Style Wall Mount Chimney Style Island Mount Chimney Style Wall Mount Professional Style Insert Mount Professional Style 2 3 Installation: 4 Table of Contents Wall Hood Installation Island Installation Professional

More information

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

Connection Diagrams (36 - 48 Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48 - 60 Widths) R DESIGNER SERIES WALL MOUNT RANGE HOOD JDH/C2 Series Equipped with LED lighting. Not available with heat lamps. Optional duct covers available in standard and custom sizes. Recommended Mounting Height

More information

Operation Manual RANGE HOOD

Operation Manual RANGE HOOD Operation Manual RANGE HOOD MODEL: BUF-021 TABLE OF CONTENTS Safety Instructions... 2 Name of Parts... 4 Operating the Range Hood... 4 How to Use... 5 Care and Maintenance... 6 Disassembling... 7 Cleaning...

More information

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance. ELECTRIC RNGE for residential use only R Models: VEFSEE 304 P.. INSTLLTION INSTRUCTIONS IMPORTNT - PLESE RED ND FOLLOW Before beginning, please read these instructions completely and carefully. Do not

More information

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS Please read all instructions thoroughly before installing the Over the Range Microwave Oven/Hood System. Two people are recommended to install this

More information

Self-Cleaning Range Hoods

Self-Cleaning Range Hoods Self-Cleaning Range Hoods Undermount Range Hoods NA930C/R CY1000C/R CY2080R CYS1000R CY1011R CY3000R NA330R Installation and Operation Instructions Please read all instructions before installing and operating.

More information

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

brisas Use, Care, and Installation Guide Brisas   BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number: brisas by www.zephyronline.com Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number: SEP08.0101 Zephyr Corporation www.zephyronline.com

More information

NTM SERIES INSTALLER: LEAVE THIS GUIDE WITH THE HOMEOWNER. HOMEOWNER: OPERATION AND CARE INFORMATION ON PAGES 9-10.

NTM SERIES INSTALLER: LEAVE THIS GUIDE WITH THE HOMEOWNER. HOMEOWNER: OPERATION AND CARE INFORMATION ON PAGES 9-10. INSTALLATION GUIDE HB0112 HB0112 NTM SERIES! INTENDED FOR DOMESTIC COOKING ONLY! READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS GUIDE WITH THE HOMEOWNER. HOMEOWNER: OPERATION AND CARE INFORMATION

More information

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments READ THIS FIRST Carefully examine the crate(s) for damage before opening. If the carton is damaged, immediately notify shipping company. If the unit(s) were shipped on wooden skids, remove protective wood

More information

ISLAND RANGE HOOD SPECIFICATIONS

ISLAND RANGE HOOD SPECIFICATIONS ISF18/ISFH18/ISL18/ISLH18/IXR18/IXRH18 H in part number indicates halogen lighting. These models not available with heat lamps. ISF18/ISFH18 ISL18/ISLH18 IXR18/IXRH18 11" 11" Dia. Island Duct Cover 9 550

More information

R a n g e H o o d Installation Guide and Users Manual

R a n g e H o o d Installation Guide and Users Manual R a n g e H o o d Installation Guide and Users Manual CONTENTS IMPORTANT SAFETY INSTRUCTIONS 1 WALL RANGE HOOD INSTALLATION 4 CROWN MOLDING INSTALLATION 9 DESIGNER WALL RANGE HOOD INSTALLATION 10 ISLAND

More information

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS Please read all instructions thoroughly before installing the Microwave Oven/Hood System. Two people are recommended to install this

More information

INSTALLATION INSTRUCTIONS FRONT CONTROL ELECTRIC RANGES

INSTALLATION INSTRUCTIONS FRONT CONTROL ELECTRIC RANGES INSTLLTION INSTRUTIONS FRONT ONTROL ELETRI RNGES Table of ontents RNGE SFETY...2 INSTLLTION REQUIREMENTS...3 Tools and Parts...3 Location Requirements...3 Electrical Requirements - U.S.. Only...5 INSTLLTION

More information

Use, Care, and Installation Guide

Use, Care, and Installation Guide Use, Care, and Installation Guide Lateral Wall VLA-E30AS VLA-E36AS Model number: Serial Number: JUN11.0101 SAFETY NOTICE... 2-3 LIST OF MATERIALS... 4 INSTALLATION Ducting Calculation Sheet... 5 Mounting

More information

INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES

INSTALLATION INSTRUCTIONS 30 (76 CM) FREESTANDING ELECTRIC RANGES INSTLLTION INSTRUTIONS 30" (76 M) RSTNING LTRI RNGS Table of ontents RNG STY...1 INSTLLTION RQUIRMNTS...2 Tools and Parts...2 Location Requirements...2 lectrical Requirements...3 INSTLLTION INSTRUTIONS...4

More information

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style.

120 Ventilation. Ventilation. Removes smoke and odor. Adds exceptional style. 120 Ventilation Ventilation Removes smoke and odor. Adds exceptional style. Ventilation 121 Ventilation Bosch s efficient, highly effective ventilation products complete any Bosch kitchen package. Capable

More information

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-XHD SERIES. TMI, LLC Managing Environments

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-XHD SERIES. TMI, LLC Managing Environments READ THIS FIRST Carefully examine the crate(s) for damage before opening. If the carton is damaged, immediately notify shipping company. If the unit(s) were shipped on wooden skids, remove protective wood

More information

Use, Care, and Installation Guide

Use, Care, and Installation Guide www.zephyronline.com Use, Care, and Installation Guide Angolo ZAG-E30AG ZAG-M90AG ZAG-E30AG290 ZAG-M90AG290 Model number: Serial Number: Date of Purchase: Sales Dealer: JAN11.0101 2011 Zephyr Corporation

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at

More information

INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER

INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER 239-47810-00 WARNING The vent-air intake system must be properly installed. Failure to properly install the vent-air intake system could result

More information

4-LIGHT VANITY FITTER

4-LIGHT VANITY FITTER ITEM #0809648 PORTFOLIO and PORTFOLIO & Design TM are trademarks or registered trademarks of LF, LL. ll rights reserved. 4-LIGHT VNITY FITTER MODEL #VB43-4BNK Français p. 9 Español p. 17 TTH YOUR REEIPT

More information

HP190SL Series Slimline Radon Fans

HP190SL Series Slimline Radon Fans Installation and Operation Manual Item #: 412843 Rev Date: 070113 HP190SL Series Slimline Radon Fans United States 10048 Industrial Blvd., Lenexa, KS, 66215 Tel.: 800.747.1762 Fax: 800.487.9915 Canada

More information

FADE Series Wall Axial Fans

FADE Series Wall Axial Fans Installation and Operation Manual Item #: 401442 Rev Date: 070113 FADE Series Wall Axial Fans Fantech Inc. certifies that the FADE Series shown herein is licensed to bear the AMCA Seal. The ratings shown

More information

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE.  By Vent-A-Hood Vline By Vent-A-Hood V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE Vline By Vent-A-Hood POWER LUNG BRINGS LUXURY & SUPERIOR PERFORMANCE TO THE VALUE RANGE HOOD CATEGORY Vent-a-hood s

More information

Anti-Pollution Ecological System

Anti-Pollution Ecological System The FST ecological system was designed to meet all types of commercial kitchen installations. The ecological system is an environmentally-friendly solution that helps maintain air quality. The main objective

More information

LIST OF MATERIALS. USE, CARE, AND INSTALLATION GUIDE Read all Instructions before Installing and operating this appliance WARNING

LIST OF MATERIALS. USE, CARE, AND INSTALLATION GUIDE Read all Instructions before Installing and operating this appliance WARNING USE, CARE, AND GUIDE Read all Instructions before Installing and operating this appliance MODELS: AK7000, AK7036, AK7042 Tempest I IMPORTANT SAFETY NOTICE WARNING Installation The installation in this

More information