Loadcentres and Circuit Breakers

Size: px
Start display at page:

Download "Loadcentres and Circuit Breakers"

Transcription

1 Loadcentres and Circuit Breakers quare D QO Loadcentres and Circuit Breakers election Guide Contents Description Page General Information QO Breakers QO Loadcentres Accessories Product Illustrations/Features 3-4 QO tandard Breakers and Tandem Circuit Breakers. 5 QO pecial Breakers (QO-GFI, QO-EPD, QO-HID, QO-AFI, QO-K, and QO-HM) 6 Circuit Breaker Factory Installed Accessories 6 Circuit Breaker Wire izes 6 QO Main Lugs Loadcentres - Type 1 Indoor 7 QO 'stand alone' Generator Panels 7 QO Combination E 'all-in-one' Generator Panels 7 QO Main Breaker Loadcentres - Type 1 Indoor 8 QO Main Lugs/Main Breaker Loadcentres - Type 3R Weatherproof 9 QO Recreational Vehicle Park (ervicepak Panels) and Mobile Home and Trailer Loadcentres 10 QO Loadcentre and Circuit Breaker Accessories 11 QO single phase loadcentre field installed neutral extension kits 12 econdary urge uppressors and urge Arresters 13 Dimensional Information Enclosure Dimensions 14 Homeline Loadcentres and Circuit Breakers election Guide General Information and Application Data Homeline Loadcentre Product Description 17 omenclature Charts 20 tandard and Main Circuit Breakers 21 Tandem and Quad Circuit Breakersr 22 GFI 22 AFCI 22 Breaker Accessories 23 Indoor ingle Phase Main Lug & Main Circuit Breaker Loadcentres 24 Outdoor ingle Phase Main Lug & Main Circuit Breaker Loadcentres 25 Homeline Fusible Loadcentre Inserts 26 Homeline Loadcentre Accessories 28 Technical Information Wiring Diagrams Indoor Loadcentre Dimensions and Knockouts 33 Outdoor Loadcentre Dimensions and Knockouts 34-1

2 Loadcentres and Circuit Breakers Federal Pioneer tab-lok Circuit Breakers election Guide General Information Features and Benefits 36 Circuit Breakers and Accessories tandard and Main Circuit Breakers 37 tab-lok Breaker Accessories 38 Ground Fault Circuit Breakers and pa Buddy 39 Arc-Fault Circuit Interrupters and tab-lok Generator Panel - Replacement Breakers 40 tab-lok Circuit Breakers Recreational Vehicle Park Power Centre - Receptacle Kits 41 Accessories tab-lok Loadcentre Accessories

3 QO Loadcentres and Circuit Breakers General Information QO Loadcentres Pages: -5 to -14 Application: Residential, commercial, and industrial 30 through 225 Amperes tandards: CA Certified under File #LL Enclosures: Type 1 and 3R Features: One piece, plated, shielded copper bus (-eries) plit branch neutral with 3-1/0 built in branch neutral lugs Combination lot/robertson neutral, ground and trim screws Additional ground bar provisions Trims have automatic flush adjustment Accessories: econdary urge Arresters ub-feed Lugs Filler Plates (for branch and main breakers) Door Lock Kits eutral Lugs QO single phase neutral extension kits -3

4 QO Loadcentres and Circuit Breakers General Information QO Circuit Breaker Branches: QO - Plug-On Circuit Breakers QO-GFI - Ground Fault Indication QOT - Tandem Breakers QO-EPD - Equipment Ground Fault Protection QO-HID - High Intensity Discharge Lighting ystems QO-K - Key Operated Breakers QO-AFI - ARC Fault Circuit Interrupters QO-HM - High Magnetics Features: QWIK-OPE Circuit Breakers VII-TRIP Indicator Tandem Circuit Breakers feature two 1-Pole breakers in the space of a 1-Pole QO breaker QO2175B URGEBREAKER econdary urge suppressor hunt Trips, Auxiliary witches, and Alarm witches are all available factory installed For additional information, QO & QOB Miniature Circuit Breakers Catalogue 0730CT9801R1/08. QO-EPD Catalogue 0950CT9601 quare D eries s Guide Catalogue D0110AB9801EP R0 econdary urge Arresters Catalogue 6671CT9701R9/06-4

5 QO Loadcentres and Circuit Breakers QO tandard and Tandem Circuit Breakers Plug-On Circuit Breakers - Amperes Interrupting (AIR) in Amperes RM ymmetrical Ampere Δ One Pole - 120/240Vac Two Pole - 120/240Vac Common Trip Three Pole - 240Vac Common Trip 10,000 AIR 10 QO110 QO210 QO QO115 QO215 QO QO115HM 20 QO120 QO220 QO QO120HM 25 QO125 QO225 QO QO130 QO230 QO QO135 QO235 QO QO140 QO240 QO QO145 QO245 QO QO150 QO250 QO QO160 QO260 QO QO170 QO270 QO QO280 QO QO290 QO QO2100 QO QO2110 QO2125 o DC rating 125 QO2150 QO2175 QO ,000 AIR 15 QO115VH QO215VH QO315VH 20 QO120VH QO220VH QO320VH 25 QO125VH QO225VH QO325VH 30 QO130VH QO230VH QO330VH 40 QO240VH QO340VH 50 QO250VH QO350VH 60 QO260VH QO360VH 70 QO270VH QO370VH 80 QO280VH QO380VH 90 QO290VH QO390VH 100 QO2100VH QO3100VH 110 QO2110VH QO2125VH 125 QO2150VH QO2175VH QO2200VH 42,000 AIR 40 QOH QOH QOH QOH QOH QOH QOH QOH QOH QOH ,000 AIR 15 QH115 QH215 QH QH120 QH220 QH QH125 QH225 QH QH130 QH230 QH330 QO One Pole 1 pace Required QO Two Pole QO One Pole Tandem 1 pace Required 2 paces Required QO Three Pole Tandem (Dual) Circuit Breakers 10,000 AIR Ampere Δ 15 & & & & & & & & & 30 One Pole - 120/240Vac Two ingle Pole Individual Trip - 120/240Vac 1 pace Required 2 paces Required QO1515 QO1520 QO1530 QO2015 QO2020 QO2030 QO3015 QO3020 QO3030 Order Two QO1515 or QO2020 Circuit Breakers and Handle Tie Catalogue # QOTHT. Δ ampere breakers are suitable for use with 60 C or 75 C conductors ampere breakers are suitable for use with 75 C conductors. High magnetic trip breakers are recommended for applications where high initial inrush current may occur. WD (switching duty) rated. uitable for switching 120Vac fluorescent lighting loads. HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. HACR labelled one pole QO breakers not stocked. Order Only. Add suffix Requires four spaces (#1-300 kcmil Al/Cu). ot suitable for use in 3-phase panel. Use only in single phase panel rated 150A or greater. CA Listed for use ahead of QO, QO-GFI, QO-EPD, QOT and QO-PL 10,000 AIR circuit breakers to permit their application at 22,000A fault level. Application Information 3 paces Required VII-TRIP indication on all QO breakers. QO, VII-TRIP and QWIK-GARD are registered trademarks of quare D. For more information consult chneider Electric. Accessories page -11. Add suffix 35 for 50 C calibration - 20% price adder. -5

6 QO Loadcentres and Circuit Breakers QO pecial Breakers Plug-On Circuit Breakers - Amperes Interrupting (AIR) in Amperes RM ymmetrical One Pole QO-AFI One Pole QO-GFI Two Pole QO-GFI QO One Pole with hunt Trip QOK Key Operated QO-GFI QWIK-GARD circuit breakers provide overload and short circuit protection, Circuit Breaker Wire izes combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more, for people protection. Do not connect to more than 250 feet of load Breaker Ampere Wire ize (AWG) conductor for the total one-way run to prevent nuisance tripping. Type Δ Aluminum Copper One Pole Two Pole-Common Trip #14-8 #14-8 QO 120Vac 120/240Vac (2) # Pole #8-2 #8-2 Ampere Δ 10,000 AIR 22,000 AIR 10,000 AIR 15 QO115GFI QO115VHGFI QO215GFI 20 QO120GFI QO120VHGFI QO220GFI 25 QO125GFI QO125VHGFI QO225GFI 30 QO130GFI QO130VHGFI QO230GFI 40 QO240GFI 50 QO250GFI 60 QO260GFI uitable only for feeding 240Vac and 208Vac 2 wire loads. Does not contain load neutral connection. QO-EPD Ampere Δ QO-K QO Circuit Breakers With 30 ma Equipment Ground Fault Protection One Pole 120Vac Two Pole-Common Trip 120/240Vac 10,000 AIR 10,000 AIR 15 QO115EPD QO215EPD 20 QO120EPD QO220EPD 25 QO125EPD QO225EPD 30 QO130EPD QO230EPD 40 QO240EPD 50 QO250EPD 60 QO260EPD Ampere Δ Key operated QO circuit breakers are available in single pole construction and can be mounted in any single pole space which will accept a standard QO. These circuit breakers can be turned O or OFF or to REET with a special key (Catalogue umber QOK10) included with the circuit breaker. One Pole 120Vac 10,000 AIR 10 QO110K 15 QO115K 20 QO120K 30 QO130K QO-HM Ampere QO circuit breaker with high magnetics to withstand higher inrush currents than standard QO breaker. One Pole 120Vac 10,000 AIR 15 QO115HM 20 QO120HM ote: QO GFI, EPD, AFI cannot be backfed. Application Information #14-8 #14-8 QO #8-2 #8-2 2 & 3 Pole #12-2/0 #12-2/0 QOT #12-8 #14-8 QO-GFI & QO-EPD #12-8 # #12-4 #14-6 QO-HID Circuit Breakers - QO-HID For Use on High Intensity Discharge Lighting ystems HID circuit breakers are for use on circuits feeding fluorescent and High Intensity Discharge (HID) lighting systems such as mercury vapour, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. Ampere Δ One Pole 120/240Vac Two Pole-Common Trip 120/240Vac Three Pole-Common Trip 240Vac 10,000 AIR 10,000 AIR 10,000 AIR 15 QO115HID QO215HID QO315HID 20 QO120HID QO220HID QO320HID 25 QO125HID QO225HID QO325HID 30 QO130HID QO230HID QO330HID 40 QO140HID QO240HID 50 QO150HID QO250HID QO-AFI QO Arc Fault Circuit Interrupters (10,000 AIR) Ampere Poles 120Vac Catalogue umber 15 1 QO115AFI / QO115CAFI 20 1 QO120AFI / QO120CAFI Circuit Breaker Factory Installed Accessories Requires Additional Pole pace. Only one accessory per breaker. QO accessory terminals for (2) #14-12 Cu. Accessories are not available for Q2, QOM1, or QOB-VH ( A) circuit breakers or QO molded case switches. Factory Installed Accessories Available On Breaker Description Add uffix To Breaker Catalogue o. 120Vac 208Vac Vac hunt Trip QO 12Vac 24Vdc 12Vdc Vac Auxiliary QO,-GFI,-EPD, A Contact 1200 witch B Contact 1201 Alarm witch QO,-GFI,-EPD, 120Vac 2100 Δ ampere breakers are suitable for use with 60 C or 75 C conductors, ampere breakers are suitable for use with 75 C conductors. WD (switching duty) rated. uitable for switching 120Vac fluorescent lighting loads. Combination AFI devices provide protection against both high-energy parallel arcing (same as existing branch/feeder AFCI s) and low energy (5A) series arcing. VII-TRIP indication on all QO breakers. QO, VII-TRIP and QWIK-GARD are registered trademarks of quare D. For more information consult chneider Electric. -6

7 QO Loadcentres and Circuit Breakers QO Main Lugs Loadcentres - Type 1 Indoor QO Main Lugs Loadcentres (1Ø - 3W) Mains Ampere umber of Circuits Main Wire ize Al or Cu (AWG/MCM) tandard QO Tandem QO Loadcentre Catalogue umber eries Trim Catalogue umber QO1L Included Al or Cu QO2L30C G01 Included Al or Cu QO2L70 Δ G01 Included 12-3 Al or 14-4 Cu QO4L100 G03 Included QO6L100/F G03 Included QO8L100/F G03 Included CQO112L100GC 01 Included CQO116L100GC 01 Included CQO124L125GC 01 Included 4-2/ CQO132L125GC 01 Included 4-2/ CQO140L125GC 01 Included CQO132L200GC 01 Included CQO140L200GC 01 Included CQO142L225GC 01 Included CQO160L225GC 01 Included Box ize (see page 14) QO Main Lugs Loadcentres (3Ø - 4W) Mains Ampere umber of Circuits Main Wire ize Al or Cu (AWG/MCM) tandard QO Tandem QO Loadcentre Catalogue umber eries Trim Catalogue umber QO403L100 Δ G01 Included 12-1 Al or 14-1 Cu QO312ML1 01 QOC16UC 4-2/ QO320ML1 01 QOC24UC 4-2/ QO324ML2 01 QOC30UC QO330ML2 01 QOC30UC QO342ML2 01 QOC42UC QO Generator Panel (1Ø - 3W) Mains Ampere Total umber of Circuits umber of circuits available for (generator) critical loads Main Wire ize Al or Cu (AWG/MCM) Box ize (see page 14) Box ize (see page 14) tandard QO Tandem QO tandard QO Tandem QO Loadcentre Catalogue umber CQO48M30DGP # CQO48M60DGP # QOGP3P3036 # QOGP3P6036 #8-2 6 QO all-in-one E Generator Panels QOGP3P # QOGP3P # QOGP3P # QOGP3P # Δ ervice entrance approved. Will not accept QO-GFI or QO-EPD breakers. Maximum 20A QO-GFI breaker or AFI breaker. Maximum 70A branch breaker. Does not include a door. hunt trip feature not available on any 3Ø loadcentres. Feed-thru lugs cannot be added in filed-use QO3125L to feed-thru to another loadcentre. Bus on 2-8 cct loadcentres is one piece, solid aluminum. Bus on cct loadcentres is one piece, tin plated copper eutral terminals, main and ground lugs on all devices are Aluminum. QODK60-2 door kit can be installed on 60A main lug loadcentre. Application Information All loadcentres are suitable for both flush or surface mounting, unless suffixed: - F - flush mounting only. - - surface mounting only. All Type 1 loadcentres are approved for vertical, horizontal, or inverted mounting. All 100A loadcentres are approved for 100A max. QO branch circuit breakers. All 125A loadcentres are approved for 125A max. QO branch circuit breakers. The maximum QO branch circuit breaker is 70 ampere (single pole), 200 ampere (two pole) and 100 ampere (three pole). Two pole QO breakers rated ampere are restricted to quare D QO ingle Phase load center, eries G1. Main lugs loadcentres cannot be field converted to service entrance approved, main breaker loadcentres. QO is a registered trademark of quare D. For more information, consult chneider Electric. GC includes ground bar combination surface/flush cover. -7

8 QO Loadcentres and Circuit Breakers QO Main Breaker Loadcentres - Type 1 Indoor Main Breaker Loadcentres (1PH - 3W) Bus Ampere Main Breaker Amps Main Breaker Factory Installed umber of Circuits tandard QO Tandem QO Loadcentre Catalogue umber eries Trim Catalogue umber Main Wire ize Al/Cu (AWG/MCM) Box ize (see page 14) CQO112M100C60 01 Included CQO112M100C Included CQO116M100C60 01 Included CQO116M100C Included CQO124M125C60 01 Included 4-2/ CQO124M125C Included 4-2/ CQO132M125C Included 4-2/ CQO132M125C Included 4-2/ CQO140M125C Included 4-2/ CQO140M125C Included 4-2/0 11 Main Breaker Factory Installed CQO132M200C 01 Included CQO140M200C 01 Included CQO160M200C 01 Included Main Breaker Loadcentres (3Ø - 4W) Bus Ampere Main Breaker Amps umber of Circuits tandard QO Tandem QO Loadcentre Catalogue umber Trim Catalogue umber Main Wire ize Al or Cu (AWG/MCM) Box ize (see page 14) eries Main Breaker Factory Installed (QO3100VH & QDL32200) QO324MB QOC30UC QO342MQB QOC342UQC Main Breakers Main Breaker Frame ize QOM1 Δ QOM2 Δ Amperage kaic Catalogue umber 30 QOM30L 40 QOM40L QOM50L 60 QOM60L 50 QOM50VHL 60 QOM60VHL QOM70VHL 100 QOM100VHL 125 QOM125VHL 100 QOM2100VHL 125 QOM2125VHL QOM2150VHL 200 QOM2200VHL 225 QOM2225VHL Lug Wire ize AWG/KCMIL Al or Cu #12-2/0 #4-2/0 #4-250 Does not include a door. Order kit # QODK60-2. Do not exceed the load centre mains rating. Rated 200A maximum with Aluminum conductors and 225A maximum with Copper conductors. Δ Main Breakers include factory installed handle padlock attachment (padlock QOM main circuit breaker in the 'off' position). Add suffix for 240Vac shunt trip. Factory Installed Accessory Bus on all devices is one-piece, solid copper, standard. eutral terminals, main and ground lugs on all devices are Aluminum, standard. Application Information All loadcentres are suitable for both flush or surface mounting. All Type 1 loadcentres are approved for vertical, horizontal, or inverted mounting. All 100A loadcentres are approved for 100A max. QO branch circuit breakers. -8 All 125A loadcentres are approved for 125A max. QO branch circuit breakers. The maximum QO branch circuit breaker is 70 ampere (single pole), 200 ampere (two pole) and 100 ampere (three pole). Two pole QO breakers rated ampere are restricted to quare D QO ingle Phase load center, eries G1. Main Breaker loadcentres are approved for service entrance use. The main breaker compartment can be sealed and the main breaker can be locked. QO-L main breakers are 10 kaic rated, QO-VHL main breakers are 22 kaic rated. QO is a registered trademark of quare D. For more information, consult chneider Electric.

9 QO Loadcentres and Circuit Breakers QO Main Lugs/Main Breaker Loadcentres - Type 3R Weatherproof Main Lugs Loadcentres (1Ø - 3W) Bus Ampere tandard QO umber of Circuits Tandem QO Loadcentre Catalogue umber eries Trim Catalogue umber Main Wire ize Al or Cu (AWG/MCM) Box ize (see page 14) QO2L70RB Δ G01 Included 12-3 Al or 14-4Cu 1RB 6 12 QO6L100RB G03 Included 8-1 2RB QO8L100RB G03 Included 8-1 2RB CQO116L100GRB 01 Included 4-1 6RB CQO124L125GRB 01 Included 4-2/0 6RB CQO140L200GRB 01 Included RB Main Lugs Loadcentres (3Ø - 4W) Bus Ampere tandard QO umber of Circuits Tandem QO Loadcentre Catalogue umber Trim Catalogue umber Main Wire ize Al or Cu (AWG/MCM) Box ize (see page 14) eries QO403L100RB Δ G01 Included 12-1 Al or 14-1 Cu 3RB QO312ML1RB 01 Included 4-2/0 4RB QO320ML1RB 01 Included 4-2/0 5RB QO330ML2RB 01 Included RB QO342ML2RB 01 Included RB Main Breaker Loadcentres (1Ø - 3W) Bus Ampere Main Breaker Amps umber of Circuits tandard QO Tandem QO Loadcentre Catalogue umber eries Trim Catalogue umber Main Wire ize Al/Cu (AWG/MCM) Box ize (see page 14) Main Breaker Factory Installed CQO18M100RB60 01 Included 4-1 4RB CQO116M100RB Included 4-1 6RB CQO124M125RB Included 4-2/0 6RB Main Breaker Factory Installed CQO140M200RB 01 Included RB on-metallic Enclosure (1Ø - 3W) Type 3R Bus Ampere umber of Circuits tandard QO Tandem QO Loadcentre Catalogue umber Trim Catalogue umber Main Wire ize Al/Cu (AWG/MCM) Box ize (see page 14) CQO24L60RM Included #14-4 / #14-4 1M QO Hot Tub / Pool / pa Pack Δ 20 to 60 amp non-metallic 2 pole QOGFCI factory installed into a type 3R enclosure CQOE220GFIM CQOE230GFIM CQOE240GFIM CQOE250GFIM CQOE260GFIM Maximum 20 A QO-GFI breaker. 60 amp, 2 wire 240V only. ot for hot tubs with neutral connection. ervice Entrance approved. ot rated for 22k AIC. Bus on 2-8 cct loadcentres is one-piece, solid aluminum. (Excluding CQO18M100RB.) Bus on 8-42 cct, -eries loadcentres is one-piece, solid copper. eutral terminals, main and ground lugs on all devices are Aluminum. Application Information All 100A loadcentres are approved for 100A max. QO branch circuit breakers. All 125A loadcentres are approved for 125A max. QO branch circuit breakers. The maximum QO branch circuit breaker is 70 ampere (single pole), 200 ampere (two pole) and 100 ampere (three pole). Two pole QO breakers rated ampere are restricted to quare D QO ingle Phase load center, eries G1.. Main Breaker loadcentres are approved for service entrance use. The main breaker compartment can be sealed and the main breaker can be locked. Main lugs loadcentres cannot be field converted to service entrance approved, mainbreaker loadcentres. Weatherproof Loadcentres are supplied with main entry hole cut in top endwall and closing cap (BCAP) installed. Hole accepts 3/4 in. to 2 in. hubs. Gasket not required. QO is a registered trademark of quare D. -9

10 QO Loadcentres and Circuit Breakers QO Recreational Vehicle Park Loadcentres (ervicepak ) QO Mobile Home and Trailer Loadcentres Recreational Vehicle Park Loadcentres (ervicepak Panels) Power Main Wire ize Ampere Outlet Canada (AWG/MCM) Mains ub-feed paces Config. ervice Catalogue o. eries Al Cu Underground or Overhead Loop-Feed Terminals - on-pedestal Mounted A 1Ø2W B 1Ø2W C 1Ø2W Underground Loop-Feed Terminals - Pedestal Mounted B 1Ø2W C 1Ø2W D 1Ø3W QO2RV40A QO2RV40AG QO2RV50B QO2RV50BG QO2RV50BGFI QO3RV75C QO3RV75CG QO2RVP50B QO2RVP50BG QO2RVP50BGFI QO3RVP75C QO3RVP75CGFI QO4RVP100D QO4RVP100DG QO4RVP100DGFI Provide electrical power to individual recreational vehicle park sites. Each receptacle protected by appropriate GFI or tandard QO circuit breaker. All receptacles and circuit breakers included. 10,000 RM ymmetrical Ampere short circuit current rating. All enclosures are rainproof. Power Outlet Configurations - Description Configuration A B C D o neutral bonding provisions. Loop-Feed provisions. Type 3R weatherproof. Optional configurations not available. Box ize (see page 14) E RVP1 E RVP1 E RVP2 E RVP1+Pedestal E RVP2+Pedestal E RVP2+Pedestal T T T T T Receptacles Catalogue umber uffix Canada Catalogue o. configuration A non-pedestal configuration B non-pedestal configuration C non-pedestal configuration B pedestal configuration C pedestal configuration D pedestal TADARD DEVICE - 2xQO x 15A 120v recpt G = 2xQO115GFI factory installed TADARD DEVICE - 1xQO115+ 1xQO x15A,1x30A 120v recpt G = 1xQO115GFI & 1xQO130 factory installed GFI = 1xQO115GFI & 1XQO130GFI factory installed TADARD DEVICE - 1xQO115+ 2xQO x15A, 2x30A 120v recpt G = 1xQO115GFI & 2xQO130 factory installed TADARD DEVICE - 1xQO115+ 1xQO x15A,1x30A 120v recpt G = 1xQO115GFI & 1xQO130 factory installed GFI = 1xQO115GFI & 1XQO130GFI factory installed TADARD DEVICE - 1xQO115+ 2xQO x15A, 2x30A 120v recpt GFI = 1xQO115GFI & 2xQO130GFI factory installed TADARD DEVICE - 1xQO115+ 1xQO xQO x15A, 1x30A 120v recpt & 1x50A 120/240v recpt G = 1xQO115GFI & 1xQO130 & 1xQO250 factory installed GFI = 1xQO115GFI & 1x10130GFI & 1xQO250 factory installed Mobile Home and Trailer Loadcentres Mains Ampere paces ervice Main Lugs Loadcentres Catalogue umber eries QO2RV40A QO2RV40AG QO2RV50B QO2RV50BG QO2RV50BGFI QO3RV75C QO3RV75CG QO2RVP50B QO2RVP50BG QO2RVP50BGFI QO3RVP75C QO3RVP75CGFI QO4RVP100D QO4RVP100DG QO4RVP100DGFI Main Wire ize (AWG/MCM) Al Cu Box ize (see page 14) Ø2W QO2L30TT G MH Ø2W QO24L50TT G MH Ø3W QO24L70T G MH Ø3W QO612L100TF/ G MH Ø3W QO612L100DTF/ G MH3 on-pedestal devices are supplied with main entry hole cut in top endwall and have closing cap (BCAP) installed. Hole accepts 3/4 in. to 2 1/2 in. hubs. Gasket not required. on-pedestal devices have provisions to field install a Type B bolt on hub on the bottom endwall. For bottom feed from a conduit riser, order Type B hub and two mounting screws P/: ; and two hex nuts, P/: For pedestal devices, a stabilizer foot is available for use in unstable ground, P/: HPF. Will not accept QO-GFI circuit breakers. Use #10 maximum size wire for QO-GFI circuit breakers. 70A Max. branch circuit breaker and 70A Max. back fed main circuit breaker. Application Information All ervicepak Panels have their breakers and receptacles factory installed and prewired. Mobile Home and Trailer Loadcentres do not come with factory installed breakers. Order separately. ervicepak Panels and Mobile Home and Trailer Loadcentres are not suitable for use as service equipment. -10 All ervicepak devices are set up for Loop-fed, therefore, there are 2 wires per phase, neutral and equipment ground. ervicepak devices are suitable for surface mounting only. Power Outlet Configurations, other than those shown above, are not available. ervicepak is a Registered Trademark of quare D. For more information, consult chneider Electric.

11 QO Loadcentres and Circuit Breakers Accessories Description Catalogue umber Handle Attachments Handle Tie: Converts any two adjacent 120/240Vac single pole QO breakers to independent trip two pole... QO1HT Converts any two adjacent 120/240Vac single pole side-by-side Tandem breakers to independent trip two poleqotht Handle Lock-Off: Clamp for holding QO single pole handle in O or OFF position... QO1LO Clamp for holding QO, either 1, 2 or 3-pole breaker handles in O or OFF position... HLO1 Handle Padlock Attachment: For padlocking single pole QO breaker in O or OFF position Loose Attachment QOHPL Fixed Attachment QO1PA For padlocking single pole side-by-side QO Tandem breaker in O or OFF position... QOTHPA For 2 and 3-pole QO breakers which require padlocking in either O or OFF position Loose Attachment.... QO1HPL Fixed Attachment..... QO1PL For padlocking QOM main circuit breakers in OFF A QOM1PA A QOM2PA For padlocking 2-Pole QO-GFI in either O or OFF position GFI2PA Mechanical Interlock Attachment: For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO breakers mounted side-by-side so that only one breaker can be O at a time... QO2DTI ub-feed lugs 125 ampere two pole plug-on 2 spaces required (#12-2/0 Al/Cu)... QO2125L 125 ampere three pole plug-on 3 spaces required (#12-2/0 Al/Cu)... QO3125L Filler Plates Fills branch breaker openings in cover... QOFP Fills QOM1 main breaker opening in cover a.... QOM1FP Fills QOM2 main breaker opening in cover a.... QOM2FP Fills main breaker opening in 3Ø covers (-eries)... KFP Lock Kits Converts door latch from spring catch to lock type... PK6FL eutral / Ground Lugs Field installed for #12 to 2 Al or #14 to 4 Cu wire... LK70A Field installed for #6 to 2/0 Al/Cu wire... LK100A Field installed for #14 to 2/0 Al/Cu wire... LK125A Field installed for #2 to 3/0 Al/Cu wire... LK150A Field installed for #4 to 300 MCM Al/Cu... LK225A eutral Extension kits Field installed on 1ph QO loadcentres ee page -12 Ground Bar Kits tandard PK15GTA with a #1 to 4/0 Cu/Al Lug.... PK15GTAL tandard PK18GTA with a #1 to 4/0 Cu/Al Lug PK18GTAL tandard PK23GTA with a #1 to 4/0 Cu/Al Lug.... PK23GTAL Insulator Kit for PK9GTA thru PK27GTA PKGTAB Miscellaneous QO main breaker barrier Retaining Kit: ecures circuit breaker to interior when used as a back-fed main. For use on QO6L100/F, RB and QO8L100/F, RB Loadcentres PK2MB ecures circuit breaker to interior when used as a back-fed main. For 3Ø Loadcentres (-eries).... PK3MB Cover ealing trap: Provides means of sealing trim mounting screws on QO load centre covers QO1E Joint Compound For use on plug-on connectors only. Recommended for use whenever QO plug-on breakers are removed and reinstalled for any reason. 57g container.... PJC7201 Touch up Paint Aerosol spray paint can AA W469X83 QO1PL QO1HT PK2MB QO2DTI PK3MB QO1PA QOAMK QOTHPA QO1LO QO1HPL PKGTAB QOFP PK6FL HLO1 HLO-1 Application Information QO is a registered trademarks of quare D. For more information consult chneider Electric. -11

12 QO Loadcentres and Circuit Breakers QO single phase loadcentre - field installed neutral extension kits Loadcentre catalogue number CQO124L125GC 1 CQO124L125GRB 1 CQO124M125C60 1 CQO124M125C100 1 CQO124M125RB100 1 CQO132L125GC 1 CQO132L200GC 1 CQO132M125C100 1 CQO132M125C125 1 CQO132M125C60 1 CQO132M125C70 1 CQO132M200C 1 CQO140L125GC 2 CQO140L200GC 2 CQO140L200GRB 2 CQO140M125C100 2 CQO140M125C125 2 CQO140M150C 2 CQO140M200C 2 CQO140M200RB 2 Reference neutral kit(s)* Loadcentre catalogue number Reference neutral kit(s)* CQO142L225GC 1 or 3 CQO160L225GC 2, 3 or 4 CQO160M200C 2, 3 or 4 CQO124M60CD 1 CQO124M100CD 1 CQO132M100CD 1 CQO132M125CD 1 CQO140M200CD 2 CQO112L100GC CQO116L100GC CQO116L100GRB CQO116M100C60 CQO116M100C100 CQO116M100RB100 CQO18M100RB60 CQO112M100C60 CQO18M100RB100 * eutral kit reference number description Reference neutral kit(s) eutral kit catalogue number eutral kit description 1 QOK1 14 neutral ports x 2 2 QOK2 22 neutral ports x 2 3 QOK3 34 neutral ports x 2 4 QOK4 41 neutral ports x 2 eutral kit is not available *Installing the eutral Bar Extensions When installing the QO neutral bar extension kits, circuit breaker mounting spaces need to be left open below the neutral extension kits for ground fault interrupters, arc fault interrupters and the larger amperage branch circuit breakers rated A that would extend beyond the neutral bars. These circuit breaker types will not fit over the OQ neutral extension kit bars. QO neutral kit - customer opportunities Increased installation flexibility Enhanced retro-fit opportunities QO neutral kit - advantages Multiple length kits available Kit includes a left and right side neutral bar Left side or right side installation option Application Information For more information, contact our Customer Information

13 QO Loadcentres and Circuit Breakers econdary urge uppressors and urge Arresters URGEBREAKER PLU uitable for use in service entrance locations. Meets requirements of CA C22.2 o. 8, UL 1449, 2nd Edition, AI/IEEE C62.41 and culus Listed. AC line protection. Four line telephone protection. Two line coaxial protection. uitable for indoor applications only. Flush or surface mounting. LED status indicator. Modular design with optional accessories. ingle Phase Three Wire 120/240 Vac Description Catalogue umber Price urgebreaker Plus DB1175C DB1175C URGEBREAKER econdary urge Arrester uitable for use in service entrance locations. Meets CA C22.2 o. 8, CA C233.1, AI/IEEE C QO2175B for QO load centers and combination devices, QOD panelboards. Plug on design requires two pole spaces. LED indicates operational status. Description QO urgebreaker culus Listed econdary urge Arrester 150Vac line to ground maximum Catalogue umber QO2175B Hard Wired econdary urge Arresters uitable for use in service entrance locations. culus Listed econdary urge Arresters. Meets CA C233.1, AI/IEEE C uitable for indoor and outdoor applications. LED indicates operational status. Description Catalogue umber Price Price QO2175B ECODARY URGE ARRETER For 1Ø systems. 150Vac phase to ground maximum. DA1175 ECODARY URGE ARRETER for 3Ø systems. 600Vac phase to ground maximum. DA3650 Catalogue umber QOAMK required for installation in QO loadcentres (see page 11 for diagram). Do not use on ungrounded systems. ystems must be solidly grounded. DA1175 DA3650 Application Information For more information, please refer to catalogue o. 6671CT

14 QO Loadcentres and Circuit Breakers Enclosure Dimensions Type 1 QO Loadcentre Enclosures Type 1 Box ize Height (in./mm) Width (in./mm) Depth (in./mm) Type 3R QO Loadcentre Enclosures Type 3R Box ize Height (in./mm) Width (in./mm) Depth (in./mm) / / /89 1M 9.80/ / / / / /76 1RB 9.50/ / / / / /83 2RB 12.75/ / / / / /95 3RB 13.00/ / / / / /89 4RB 19.00/ / / / / /95 5RB 22.00/ / / / / /95 6RB 22.25/ / / / / /95 7RB 30.00/ / / / / /95 8RB 34.00/ / / / / /95 9RB 38.00/ / / / / / / / / / / / / / /95 Recreational Vehicle Park Loadcentres Mobile Home and Trailer Loadcentres Box ize Height (in./mm) Width (in./mm) Depth (in./mm) Box ize Height (in./mm) Width (in./mm) Depth (in./mm) RVP1 8.50/ / /147 MH1 6.72/ / /76 RVP / / /147 MH2 9.30/ / /81 Pedestal 50.90/ / /89 MH / / /97 Application Information Dimensions for approximate only. Do not use for construction. -14

15 Intentionally left blank -15

16 Canadian Homeline Circuit Breakers and Loadcentres General Information Canadian Homeline ingle Phase Loadcentres Pages: -17 to -34 Application: Residential, Light Commercial 30 through 225 Amperes tandards: CA Certified under File #LL Enclosures: Type 1 and 3R Features: One piece, plated, shielded aluminum bus plit branch neutral with 3-1/0 built in branch neutral lugs Combination lot/robertson neutral, ground and trim screws Additional ground bar provisions Trims have automatic flush adjustment Fusible loadcentre inserts (HFLCI) Accessories: econdary urge Arresters ub-feed Lugs Filler Plates (for branch and main breakers) Door Lock Kits eutral Lugs eutral extension kits -16

17 Canadian Homeline Circuit Breakers and Loadcentres Product Description The Residential olution for Canadian Electrical Contractors Homeline Main Breaker Loadcentre Flush Cover Homeline circuit breaker loadcentres from chneider Electric are CA certified panelboards. They are designed to meet residential requirements to protect electrical systems, equipment, and people. Features Indoor (EMA Type 1), Main Breaker, 12 to 60 spaces ingle phase, 120/240V 200A maximum tin plated aluminum bus 60 spaces, 120 circuits max hort circuit rating k standard 22kAIC main breaker (50A thru 200A) k series ratings up to 100kAIC Distributed neutral bar design Robertson/lot neutral, ground and trim screws hielded bus bar Appliance white combination flush/surface mount trim Automatic flush trim adjustment with shutter type twistouts Top or bottom feed Multiple horizontal and vertical ground bar mounting positions traight in wiring for main and branch wiring Removable interiors Tangential main knockouts Provision for optional door lock Welded box construction Indoor (EMA Type 1), Main Lug, 2 to 42 spaces ingle phase, 120/240V 225A maximum tin plated aluminum bus 42 spaces, 84 circuits max hort circuit rating k standard 10kAIC main lug k series ratings up to 100kAIC Robertson/lot neutral, ground and trim screws 2 to 6 space single row loadcentres, AA49 grey Top or bottom feed Welded box construction Homeline Fusible Loadcentre Inserts (HFLCI) Indoor (EMA Type 1), Main Lug, 12 spaces ingle phase, 120/240V 125A maximum tin plated aluminum bus 12 spaces, 24 circuits max hort circuit rating k standard 10kAIC k series ratings up to 100kAIC Robertson/lot neutral, ground and trim screws Architectural white surface mount trim with door -17

18 Canadian Homeline Circuit Breakers and Loadcentres General Information and Application Data Outdoor (EMA Type 3R), Main Breaker, 8 to 20 spaces ingle phase, 120/240V 200A maximum tin plated aluminum bus 20 spaces, 40 circuits max hort circuit rating k standard 22kAIC main breaker k series ratings up to 100kAIC Distributed neutral bar design Robertson/lot neutral, ground and trim screws hielded bus bar ide hinged door Welded, galvanealed steel, painted AA49 grey enclosure Gasketless rain hubs 0.75 to 2.5 tainless steel locking hasp Outdoor (EMA Type 3R), Main Lug, 2 to 12 spaces ew RB Device ingle phase, 120/240V 125A maximum tin plated aluminum bus 12 spaces, 24 circuits max hort circuit rating k standard 10kAIC main lug k series ratings up to 100kAIC Robertson/lot neutral, ground and trim screws Welded, galvanealed steel, painted AA49 grey enclosure Gasketless rain hubs 0.75 to 2.5 tainless steel locking hasp Bolt-On Hubs -18

19 Canadian Homeline Circuit Breakers and Loadcentres General Information and Application Data Main breakers, branch breakers and surge suppressors CHOM 1-Pole 1 space required. CHOMT 1-Pole Tandem 1 space required. CHOM 1-Pole GFI 1 space required. CHOM 2-Pole 2 spaces required. CHOMT Quad Circuit Breaker 2 spaces required. CHOM 2-Pole GFI 2 space required. CA File # LL Accepts 60/75C wire up to 40A, 75C wire over 40A HACR rated WD rating on 1 15A and 20A breakers 1-pole and 2-pole tandard 1 per pole Twin 1/2 per pole Quad 1/2 per pole Main breakers k 30A thru 225A Branch breakers 15A thru 200A Optional high magnetic on 1 15A and 20A breakers ubfeed lugs k 125A or 225A Arc-fault circuit interrupters 20A max Combination arc-fault circuit interrupters 20A max k enses series and parallel arcing Ground fault circuit interrupters 50A max k 5mA Class A k 30mA equipment protective devices k pa packs Accessories k handle lock offs k handle ties k branch filler plates Plug-in surge suppressors k Electronic MOV technology k Plug-in or knockout mounted Branch Circuit Breakers 10,000 AIR CHOM-AFI 1 space required. CHOM CHOMT CHOM-GFI CHOM-AFI CHOM-CAFI 1-pole, A 2-pole, A 1-pole, A 2-pole, A 1-pole, 15 & 20 A 2-pole, 15, 20, 30, 40, 50 A 1-pole, 15 & 20 A 1-pole, 15 & 20 A QOM1 Frame ize QOM2 Frame ize -19

20 Canadian Homeline Circuit Breakers and Loadcentres Product Description Canadian Catalogue umber logic Homeline Loadcentres umber egment Character Description CHOM 3060 L 200 G C Load Center Family CHOM CA Listed paces / Circuits 3060 Mains Type Amps M L Main circuit breaker Main lugs Ground Bar G Factory included Cover C F RB Combination flush / surface indoor cover Flush Rainproof urface Homeline Circuit Breakers umber egment Character Description CHOM 1 15 Brand umber of Poles Amps Device ame CHOM CHOMT AFI BB CAFI EPD GFI HM Full ize Tandem/Quad Arc fault circuit interruption High amp branch breaker Combination arc fault circuit interruption Equipment protection device Ground fault circuit interruption High magnetic trip otes: 1. CHOM 1pole - 1" wide, 1 space required. 2. CHOM 2pole - 2" wide, 2 spaces required. 3. CHOMT 1pole tandem - 1" wide, 1 space required,represents two 1pole circuit breakers, i.e. CHOMT CHOMT 2pole tandem quad - 2" wide, 2 spaces required, represents two 1pole outer poles and one 2pole inner circuit breaker with common trip, i.e. CHOMT

21 Canadian Homeline Circuit Breakers and Loadcentres Circuit Breakers and Accessories tandard and Main Circuit Breakers tandard Loadcentre Breakers Type CHOM 1, 2 & 4 CHOM 5 high magnetic CHOM 1 & 3 Amp 1 Pole Cat. o. Lug Range 2 Pole Cat. o. Lug Range 15 CHOM115 CHOM CHOM120 CHOM220 #14 - #8 25 CHOM125 CHOM CHOM130 CHOM CHOM CHOM140 CHOM #8-#2 50 CHOM150 CHOM CHOM115HM #14-#8 20 CHOM120HM 60 CHOM CHOM CHOM CHOM CHOM CHOM CHOM2150BB 175 CHOM2175BB 200 CHOM2200BB #14 - #8 otes: 1. All CHOM 1 & 2 pole CA listed as HACR type. 2. CHOM115 & 120 WD rated. 3. CHOM2P150-2P200 require 4 spaces, use only in single phase loadcentres rated 150A or greater. 4. CHOM 1pole circuit breakers require one space. CHOM 2pole circuit breakers require two spaces. 5. High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur. #8-#2 #4-2/0 #4-300mcm Homeline Main Circuit Breakers Type QOM1 QOM2 Amp 2 Pole Cat o. kaic Lug Range 30 QOM30L QOM40L QOM50VHL 60 QOM60VHL 70 QOM70VHL 80 QOM80VHL 100 QOM100VHL 125 QOM125VHL QOM2100VHL 125 QOM2125VHL 150 QOM2150VHL 200 QOM2200VHL 225 QOM2225VHL #12-2/0 #4-300mcm QOM2-21

22 Canadian Homeline Circuit Breakers and Loadcentres Circuit Breakers and Accessories CHOMT Breakers, Ground Fault Circuit Interrupters, Arc Fault Circuit Interrupters CHOMT Tandem & Quad Tandem Circuit Breakers Type Amp CHOMT Tandem Cat. o. Lug Range CHOMT Tandem 1 & CHOMT CHOMT CHOMT CHOMT CHOMT3020 1P 2P Quad CHOMT Tandem Cat. o. (2)15A 15A CHOMT (2)15A 20A CHOMT (2)15A 25A CHOMT CHOMT (2)15A 30A CHOMT Quad (2)15A 40A CHOMT Tandem 1, 2 & 4 (2)15A 50A CHOMT (2)20A 20A CHOMT (2)20A 25A CHOMT (2)20A 30A CHOMT (2)20A 40A CHOMT (2)20A 50A CHOMT otes: 1. CA certified for use as HACR type circuit breakers. 2. Cat# represents two 1P outer poles and one 2P inner circuit breaker with common trip. 3. CHOMT tandems require 1 space. 4. CHOMT quad tandems require 2 spaces. Ground Fault Devices (GFI) Homeline GFI with 5 ma ensitivity (Class A) Amp 1 Pole Cat. o. 2 Pole Cat. o A #14-# A #14-# A #6-12 Al #6-14 Cu pa Pack A complete kit consisting of a Type 3R enclosure, factory installed 2P50A GFCI circuit breaker. 15 CHOM115GFI CHOM215GFI 20 CHOM120GFI CHOM220GFI 30 CHOM230GFI 40 CHOM240GFI 50 CHOM250GFI pa Pack Amp Poles Cat. o CHOME250PA Homeline EPD with 30 ma ensitivity Type 1 Pole Cat. o. 2 Pole Cat. o. 15 CHOM115EPD CHOM215EPD 20 CHOM120EPD CHOM220EPD 30 CHOM230EPD 40 CHOM240EPD 50 CHOM250EPD otes: 1. GFI breakers maximum 250 feet (one way) feeder length 2. Use solid conductor only when #14 wire is used Homeline - Arc Fault Circuit Interrupters (10,000 AIR) Ampere Poles 120Vac Catalogue umber tandard Combination 15 1 CHOM115AFI CHOM115CAFI 20 1 CHOM120AFI CHOM120CAFI Arc faults are any abnormal flow of electricity that create an arc, spark or flash which is hot and capable of igniting flammable materials, thereby increasing the potential for a residential fire. CHOM115GFI CHOM230GFI -22

23 Canadian Homeline Circuit Breakers and Loadcentres Circuit Breakers and Accessories Homeline Breaker Accessories Description Handle attachments Handle tie, converts any 2 adjacent 1P HOM circuit breakers to independent trip 2P Handle tie, converts any adjacent 1P side by side HOMT CB's to independent 2P Handle lock, O or OFF, nonpadlocking Homeline 1p 15-50A CB Handle blocking device, attaches to a HOM 2P CB for holding the handle in the OFF position Handle lock, O or OFF, padlocking Homeline 1p 15-50A CB Cat. o. HOM1HT HOMTHT QO1LO HOM2HBD HOM1PA 2 pole standard Homeline handle lock O or OFF, Padlocking - Handle padlock attachment, for padlocking 2P 15-70A HOM2PALA - Handle padlock attachment, for padlocking 2P A HOM2PAHA - Handle padlock attachment, for padlocking 2P A HOM2PAVHA Handle padlock attachment, for padlocking centre poles of HOM quad breakers in the OFF position Handle lock, OFF for QOM A Main Circuit Breaker Handle lock, OFF for QOM A Main Circuit Breaker HOMQPA QOM1PA QOM2PA ub-feed Lugs 125A 2P plug-on - 2 spaces required 225A 2P plug-on - 4 spaces required HOML2125 HOML2225 ote: Canadian Homeline and QO loadcentre accessories may be common. -23

24 Canadian Homeline Circuit Breakers and Loadcentres Type 1 Main Lug and Main Circuit Breaker Loadcentres ingle-phase, Three-Wire, 120/240 Vac Main Lugs Indoor Mains in Amps Loadcentre Catalogue umber Factory-Installed Main Lugs Maximum umber of Circuits tandard 1 Tandem or Quad Loadcentre Cover Catalogue umber ervice Entrance Approved Maximum hort Circuit Main Wire ize AWG/kcmil Al/Cu Enclosure o. (Pages 33-34) Top or Bottom Mains Position 70 CHOM24L70F/ 2 4 Included 10,000 A #12 3 # Top 100 CHOM612L100F/ 6 12 Included 10,000 A #8 1 4 Top 125 CHOM48L125GC 4 8 Included 10,000 A #4 2/0 21 Top Factory-Installed Main Lugs CHOM816L125GC 8 16 Included 10,000 A #6 2/0 6 Both 125 CHOM1224L125GC Included 10,000 A #6 2/0 6 Both CHOM1632L125GC Included 10,000 A #6 2/0 8 Both CHOM2448L125GC Included 10,000 A #6 2/0 8 Both Factory-Installed Main Lugs CHOM3060L225GC Included 10,000 A # Both 225 CHOM4284L225GC Included 10,000 A # Both ingle-phase, Three-Wire, 120/240 Vac Main Circuit Breaker Indoor Mains in Amps Loadcentre Catalogue umber Maximum umber of Circuits tandard 1 Factory-Installed Main Circuit Breaker * 100 amp Main Breaker factory installed. k Does not include a door. Order kit # CHOMDK602. Tandem or Quad Loadcentre Cover Catalogue umber ervice Entrance Approved Maximum hort Circuit Main Wire ize AWG/kcmil Al/Cu Enclosure o. (Pages 33-34) Top or Bottom Mains Position 30 CHOM1224M30GC Included Y 10,000 A #6-2/0 6 Both 50 CHOM1224M50GC Included Y 22,000 A #6-2/0 6 Both CHOM1224M60GC Included Y 22,000 A #6-2/0 6 Both CHOM1632M60GC Included Y 22,000 A #6-2/0 7 Both CHOM1224M70GC Included Y 22,000 A #6-2/0 6 Both CHOM1632M70GC Included Y 22,000 A #6-2/0 7 Both CHOM1224M100GC Included Y 22,000 A #6-2/0 6 Both CHOM1632M100GC Included Y 22,000 A #6-2/0 7 Both CHOM2448M100GC Included Y 22,000 A #6-2/0 8 Both CHOM3060M100GC Included Y 22,000 A #6-2/0 10 Both CHOM1224M125GC Included Y 22,000 A #6-2/0 6 Both CHOM1632M125GC Included Y 22,000 A #6-2/0 8 Both 125 CHOM2448M125GC Included Y 22,000 A #6-2/0 8 Both CHOM3060M125GC Included Y 22,000 A #6-2/0 10 Both Factory-Installed Main Circuit Breaker CHOM2040M150GC Included Y 22,000 A # Both CHOM3060M150GC Included Y 22,000 A # Both CHOM2040M200GC Included Y 22,000 A # Both CHOM3060M200GC1 * Included Y 22,000 A # Both CHOM3060M200GC Included Y 22,000 A # Both CHOM4284M200GC1 * Included Y 22,000 A # Both CHOM4284M200GC Included Y 22,000 A # Both CHOM60120M200GC Included k Y 22,000 A # Both - Main Breaker loadcentres are approved for service entrance use. The main breaker compartment can be sealed and the main breaker can be locked. - All type 1 loacentres are approved for vertical, horizontal, or inverted mounting. -24

25 Canadian Homeline Circuit Breakers and Loadcentres Type 3R Main Lug and Main Circuit Breaker Loadcentres ingle-phase, Three-Wire, 120/240 Vac Main Lugs Rainproof Mains in Amps Loadcentre Catalogue umber Maximum umber of Circuits tandard 1 Tandem or Quad Loadcentre Cover Catalogue umber ervice Entrance Approved Maximum hort Circuit Main Wire ize AWG/kcmil Al/Cu Enclosure o. (Pages 33-34) Top or Bottom Mains Position Factory-Installed Main Lugs 70 CHOM24L70RB 2 4 Included 10,000 A #12 3 Al #14 4 Cu 1R Top 100 CHOM612L100RB 6 12 Included 10,000 A #8 1 2R Top 125 CHOM48L125GRB 4 8 Included 10,000 A #12 2/0 Al #14 2/0 Cu 15R Top Factory-Installed Main Lugs 125 CHOM816L125GRB 8 16 Included 10,000 A #6 2/0 3R Top CHOM1224L125GRB Included 10,000 A #6 2/0 3R Top ingle-phase Three Wire 120/240 Vac Main Breaker Rainproof Factory-Installed Main Circuit Breaker 100 CHOM816M100GRB 8 16 Included Y 22,000 A #6-1 3R Top CHOM1224M100GRB Included Y 22,000 A #6-2/0 3R Top Factory-Installed Main Circuit Breaker 200 CHOM2040M200GRB Included Y 22,000 A # R Top -25

26 Canadian Homeline Circuit Breakers and Loadcentres Loadcentres Homeline Fusible Loadcentre Inserts (HFLCI) Fusible Loadcentre Inserts tep 1 tep 2 tep 3 tep 4 Identify Box Dimensions and Catalogue umber Remove Old Fusible Interior Install ew HFLCI Complete Installation Homeline Fusible Loadcentre Inserts (HFLCI) offer the safety and reliability of a modern circuit breaker loadcentre system featuring Homeline circuit breakers. Easily replaces outdated fusible loadcentres. Eliminates drywall removal and repair. Eliminates painting new drywall. o holes to drill. o new ground required. o branch conductors or conduit to remove. Using the Homeline FLCI substantially reduces installation time, as much as 80%, allowing for the economical replacement of old fusible loadcentres. -26

27 Canadian Homeline Circuit Breakers and Loadcentres Loadcentres Homeline Fusible Loadcentre Inserts (HFLCI) READ THI FIRT To select the proper HFLCI, follow these three steps: tep 1: Find your fusible loadcentre catalogue number using columns 1 and 2. tep 2: Confirm that the original fusible loadcentre box dimensions match those in columns 5, 6, and 7. tep 3: Use column 3 to identify the Homeline Fusible Loadcentre Insert (HFLCI) catalogue number. CAUTIO: Do not proceed with an installation unless both the existing catalogue number and box dimensions match Original Manufacturer Original Main Lug Loadcentre Catalogue umber Homeline Catalogue umber** ote: ot suitable for use with Canadian Homeline AFI or GFI devices. Maximum umber of Circuits Box Dimensions Height Width Depth tandard 1 Tandem or Quad Inches mm Inches mm Inches mm Amalgamated Electric 4208 HFLCI12D Amalgamated Electric 4212 HFLCI16D Amalgamated Electric 4220 HFLCI20AD Amalgamated Electric 4220 HFLCI24AD Amalgamated Electric 4216 HFLCI20BD Amalgamated Electric 4216 HFLCI24BD Amalgamated Electric 4312 HFLCI20BD Amalgamated Electric 4312 HFLCI24BD CEB HP HFLCIC16BD CEB HP HFLCIC20BD CEB HP HFLCIC20ED CEB HP HFLCIC24BD CEB HP12-60 HFLCIC12DD CEB HP HFLCIC20AD CEB HP HFLCIC24AD CEB HP4-632 HFLCIC12BD CEB HP HFLCIC16D CEB HP HFLCIC16D CEB HP6-60 HFLCIC12CD CEB HP HFLCIC16BD CEB HP HFLCIC16CD CEB HP8-60 HFLCIC12D CEB HP HFLCIC20AD CEB HP HFLCIC24AD Taylor (Crouse Hinds) HP0020 HFLCIT8AD Taylor (Crouse Hinds) HP HFLCIT16AD Taylor (Crouse Hinds) HP1231 HFLCIT20AD Taylor (Crouse Hinds) HP HFLCIT20AD ** Homeline FLCI s include distribution section interior, trim, door and painted architectural white. -27

28 Canadian Homeline Circuit Breakers and Loadcentres Accessories RB Hub Plug-in surge breaker Ground bars eutral lugs Filler plates Type 3R rain hubs Type 3R coupling trough Door lock Main lugs Replacement covers Replacement interiors BC200 Enclosure Coupling CHOM urgebreaker urge Arrester 2 spaces required. PK6FL PK15GTA LK100A QOL125 HOMFP QOM1FP QOL225 QOM2FP -28

29 Canadian Homeline Circuit Breakers and Loadcentres Homeline Loadcentre Accessories Homeline Replacement Interior, 1 Phase, Type 1 Enclosures OL urge Protective Device Reference Loadcentre Catalogue umber CHOM24L70/F/RB CHOM612L100/F/RB CHOM48L125GC CHOM48L125GRB CHOM816L125GC CHOM816L125GRB CHOM1224L125GC CHOM1224L125GRB CHOM1632L125GC CHOM2448L125GC CHOM3060L225GC CHOM4284L225GC Replacement Interior Catalogue umber CHOM24L70I CHOM612L100I CHOM48L125GCI CHOM48L125RBI CHOM816L125GCI CHOM816L125GRBI CHOM1224L125GCI CHOM1224L125GRBI CHOM1632L125GCI CHOM2448L125GCI CHOM3060L225GCI CHOM4284L225GCI Description urge arrester for 1PH3W system 150Vac maximum phase-to-ground Interchangeable Hubs Conduit ize Type B Hubs Closing Plate BCAP 3/4" B075 1" B /4" B /2" B150 2" B /2" B250 Catalogue umber CHOM2175B Replacement Covers, 1 Phase, Type 1 Enclosures OL Reference Loadcentre Catalogue umber * o door on cover. Replacement Cover Catalogue umber CHOM24L70 * CHOM24L70RB CHOM24L70F * CHOM48L125GC CHOM48L125GRB CHOM612L100 * CHOM612L100F CHOM612L100RB CHOM816M100GRB CHOM1224M100GRB CHOM2040M200GRB CHOM 8-16,12-24 ML-MB loadcentres CHOMC12UC CHOM A MB loadcentres CHOMC21UC CHOM A, ML-MB loadcentres CHOMC24UC CHOM A MB loadcentres CHOMC30U125C CHOM A ML-MB loadcentres CHOMC30UC CHOM ML-MB loadcentres CHOMC42UC CHOM MB loadcentres CHOMC20UC Door Lock Kits, 1 Phase, Type 1 Enclosures OL Catalogue umber Description PK6FL For use with type 1 Canadian Homeline Loadcentres. Coupling Trough Catalogue umber BC200 Filler Plates Description Branch Breaker QOM1 Main Breaker QOM2 Main Breaker Optional eutral Lugs Wire ize Description BC200 - enclosure coupling for RB devices Catalogue umber HOMFP QOM1FP QOM2FP Catalogue umber #12-2 AL #14-4 Cu LK70A #6-2/0 AL/Cu LK100A #14-2/0 AL/Cu LK125A #2-3/0 Al/Cu LK150A Main Lug Kits Catalogue umber QOL125 QOL225 B-150 Description 125A Kit 225A Kit -29

30 Canadian Homeline Circuit Breakers and Loadcentres Technical Information TECHICAL IFORMATIO Grounding Bar Kits lot / Robertson screw [11] All PK equipment grounding bar kits are supplied with mounting screws, necessary installation instructions and an Equipment Grounding Terminal self-adhesive label. Catalogue umber Total Qty. Terminals Quantity Each ize ee Wire Range Table below. Approximate Overall Length Distance Between Mounting Holes Mounting I II III IV V VI in mm in mm [8] Cross ection of ize 1 Ground Bar in Dimensions: [mm] PK0GTA [44] One hole One hole PK0GTA [117] 1.69 [43] Top PK3GTA [35] PK4GTA [41] One hole One hole One hole One hole PK5GTA [57] 1.25 [32] Top PK7GTA [73] 1.25 [32] PK9GTA [83] One hole One hole Top Top Top Top or ide PK9GTA [96] 3.13 [80] Top PK12GTA [119] 3.13 [80] Top PK15GTA [143] 3.13 [80] Top PK15GTAL [207] 3.13 [80] Top PK15GTA [149] 2 Top PK18GTA [167] 3.13 [80] Top PK18GTAL [224] 3.13 [80] Top PK23GTA [206] 3.13 [80] Top PK23GTAL [240] 3.13 [80] Top PK27GTA 3 27 or or 26 1 Mounting screws (two required) and (two required) in. (80 mm) on small terminals; 5.25 in. (133 mm) on large terminals. 3 PK27GTA includes one main grounding lug that mounts with two terminal screws and requires three terminals for mounting. Top [238] 3.13 [80] Top Wire Range Table ize Cu (AWG) Al (AWG) I (1) #14 #4 or (2) #14 or #12 (1) #12 #4 or (2) #12 or #10 II (1) #1 4/0 (1) #1 4/0 III (1) #6 2/0 (1) #6 2/0 IV (1) #6 3/0 (1) #6 3/0 V (1) #14 1/0 (1) #14 1/0 VI (1) #10 2/0 (1) #6 2/0-30

31 Canadian Homeline Circuit Breakers and Loadcentres Wiring Diagrams WIRIG DIAGRAM / CHOM24L70/F CHOM24L70RB CHOM612L100/F CHOM612L100RB CHOM816L125GC CHOM816L125GRB CHOM1224L125GC CHOM1224L125GRB CHOM1632L125GC CHOM2448L125GC CHOM3060L225GC CHOM4284L225GC -31

32 Canadian Homeline Circuit Breakers and Loadcentres Wiring Diagrams MAI MAI CHOM816M100RB CHOM1224M100GC CHOM1224M125GC CHOM1224M100GR MAI MAI MAI CHOM1632M100GC CHOM1632M125GC CHOM2040M150GC CHOM2040M200GC CHOM2040M200GRB CHOM244M100GC CHOM244M125GC MAI MAI MAI CHOM3060M100GC CHOM3060M125GC CHOM3060M150GC CHOM3060M200GC CHOM3060M200GC1 CHOM4284M200GC CHOM4284M200GC1 CHOM60120M200GC 1-Phase, 3-Wire Main Circuit Breakers -32

33 Canadian Homeline Circuit Breakers and Loadcentres Indoor Dimensions and Knockouts IDOOR DIMEIO AD KOCKOUT Box o. Indoor Dimensions W H D in. mm in. mm in. mm * Knockouts ymbol A B C D E F G H I Conduit ize 0.50 in. 13 mm 0.75 in. 19 mm 1.00 in. 25 mm * ote: Box 24 knockout drawing to follow. A, B, C A A A, B, C, D A, B, C Box in. 32 mm 1.50 in. 38 mm 2.00 in. 51 mm A, B B, C, D, E A 2.50 in. 64 mm A Box 4 B, C, D, E 3.00 in. 76 mm B, C, D, E B, C, B, C, D, E D, E B, C, D, E 3.50 in. 89 mm B, C, D, E C, D, E, F A, B A C, D, E, F,G A Box 7 A, B B, C, D, E A, B, C, D B, C, D, E C, D, E, F C, D, E, F,G A A, B B, C, D, E B, C, D,E C, D, E, F C, D, E, F,G A A, B B, C, D, E C, D, E, F D, E, F, G B, C A, B C, D, E, F,G A A, B B, C, D, E D, E, F, G A, B A A Box 6 A, B, C, D B, C, D, E Box 8 A, B, C, D D, E, F, G Box 9 A, B, C, D C, D, E, F B, C, D, E C, D, E, F D, E, F, G B, C C, D, E, F,G A A, B B, C, D, E D, E, F, G B, C, D, E B, C, D, E D, E, F, G B, C C, D, E, F, G A A, B C, D, E, F D, E, F, G A, B A A, B A A, B B, C, D, E A B, C, D, E B, C, D, E A D, E, F, G Box 10 A, B, C, D, C, D, E, F C, D, E, F Box 12 A, B, C, D B, C, D, E B, C, D, E B, C, D, E B, C, D, E Box 21-33

34 Canadian Homeline Circuit Breakers and Loadcentres Outdoor Dimensions and Knockouts OUTDOOR DIMEIO AD KOCKOUT Outdoor Dimensions W H D Box o. in. mm in. mm in. mm 1R R R R R CHOME250PA top endwall has no hub opening. Knockouts ymbol A B C D E F G H Conduit ize 0.50 in. 13 mm 0.75 in. 19 mm 1.00 in. 25 mm 1.25 in. 32 mm 1.50 in. 38 mm 2.00 in. 51 mm 2.50 in. 64 mm 3.00 in. 76 mm 2.5 in. (64 mm) Hub Max. 2.5 in. (64 mm) Hub Max. 2.5 in. (64 mm) Hub Max. C, D, E F, G A, B, C, D Box 1R A A, B B, C, D, E B, C, A B, C, D, E A, B D, E Box 2R C, D, E, F A A, B C, D, E, F, G Box 3R C, D, E, F A, B, C 2.5 in. (64 mm) Hub Max. C, D, E, F, G 2.5 in. (64 mm) Hub Max. C, D, C, D, E, F E, F A A, B, C A, B C, D, E, F, G Box 6R B, C, D, E A B, C, D, E B, C, D, E A, B Box 15R E.&O.E. -34

35 Intentionally left blank -35

36 tab-lok Circuit Breakers General Information Features and Benefits Breaker Features: Type C with Robertson/slot screws Type C with colour coded handles Thermal magnetic trip protection Exclusive line side stab connection Trip free operation Calibrated at 40 C Availability of a wide range of GFCIs Arc resistant case C The Compact tab-lok Breaker - 1/2 Wide per pole tab-lok Breaker Table Type Poles Amp Maximum Voltage Interrupting Capacity C ,000 A /240 10,000 A ,000 A A /240 10,000 A ,000 A 1C ,000 A 120/ ,000 A 2C /240 22,000 A C015, C0215, C0230 A The Original tab-lok Breaker - 1 Wide per pole A15 A215 A3P20 A2P100-36

37 tab-lok Circuit Breakers Circuit Breakers and Accessories tandard and Main Circuit Breakers tandard Loadcentre Breakers Type C A Amp 1 Pole Cat. o. List Price Lug Range otes: 1. A2P150 rated 150A when used with copper conductor only 2. witching duty approved breakers. Breakers are marked WD 3. 2-pole and 3-pole breakers greater than 70A take 4 and 6 A breaker positions respectively 4. Use solid conductor only when #14 wire is used 5. 2 Pole Cat. o. List Price Lug Range 3 Pole Cat. o. 15 C015 C C020 C C025 #14 - #6 C0225 #14 - #6 30 C030 C C040 C C050 #14 - #4 C0250 #14 - #4 15 A15 (2) A215 A3P15 20 A20 (2) A220 A3P20 25 A25 A A30 #14 - #2 A230 A3P30 35 A35 #14 - #2 40 A40 A240 A3P40 50 A50 A250 A3P50 60 A260 A3P60 70 A270 A3P70 90 A2P90 A3P A2P100 A3P100 #4-2/0 125 A2P A2P150 1 List Price Lug Range #14-1/0 tab-lok Main Circuit Breakers Type Amp 2 Pole Cat o. List Price Lug Range 3 Pole Cat o. List Price Lug Range A Use Breaker Table Above 30 1C C C50 1C 60 1C60 #4-2/0 70 1C C C C C C125 2C 150 2C150 #4-250MCM 175 2C C200 2C200 C015/C0215 Breaker Handle Colour - Blue C020/C0220 Breaker Handle Colour - Red C030/C0230 Breaker Handle Colour - Green C040/C0240 Breaker Handle Colour - Grey -37

38 tab-lok Circuit Breakers tab-lok Breaker Accessories tab-lok Breaker Accessories Breaker Type Poles Amp C A ote: tandard Packaging ize for all breaker accessories is 10 Handle Lock Off on- Padlocking Handle Lock Off Padlocking Handle Tie Cat. o. List Price Cat. o. List Price Cat. o. List Price CLOK (3) / 1LOK (2) CTIE (1) / HTC (2) CLOK (ot suitable for ribbed handles) HTA LOK 1LOB (ot to be used for 2 pole applications) 2LOK (2 3 pole modular) CLOK 3 on - Modular 3100LOK 3 Modular 2LOK 1. uitable for ribbed handled C breakers. 2. uitable for square handled C breakers. 3. uitable for ribbed handled C 1 2 pole breakers. -38

39 tab-lok Circuit Breakers Ground Fault Circuit Breakers and pa Pack Circuit Breakers tab-lok GFI with 5 ma ensitivity (Class A) Type A Amp 1 Pole Cat. o. List Price 2 Pole Cat. o. 15 AGF15 AGF AGF20 AGF AGF30 AGF AGF40 AGF240 List Price tab-lok GFI with 33 ma ensitivity Type Amp 1 Pole Cat. o. List Price 2 Pole Cat. o. List Price 15 AGF1533 AGF AGF2033 AGF22033 A 30 AGF3033 AGF AGF4033 AGF24033 otes: 1. ubmersible pump installations require ground fault protection to the maximum sensitivity level of 10mA. These breakers are designed to meet the Canadian Electrical Code under rule CEC GFI breakers maximum 250 feet (one way) feeder length 3. Use solid conductor only when #14 wire is used 4. GFI 15 Amp Handles - Blue, GFI 20 Amp Handles - Red, GFI 30 Amp Handles - Green, GFI 40 Amp Handles - Grey tab-lok GFI with 10mA ensitivity Type Amp 2 Pole Cat. o. List Price A AGF15 15 AGF AGF AGF AGF24010 AGF215-39

40 tab-lok Circuit Breakers Arc-Fault Circuit Interrupters and tab-lok Generator Panel - Replacement Breakers As per the Canadian Electrical Code (CEC), AFCIs will be required for ALL bedroom receptacle circuits beginning anuary The CEC does not mandate existing homes be upgraded with AFCIs. However, if a new bedroom is added, the AFCI will be required. Reduce the risk of fire with the installation of Federal Pioneer arc-fault circuit interrupters. tab-lok - AFCI tab-lok Arc Fault Circuit Interrupters (10,000 AIR) Ampere Poles 120Vac Catalogue umber 15 1 A15AFI 20 1 A20AFI Arc faults are any abnormal flow of electricity that create an arc, spark or flash which is hot and capable of igniting flammable materials, thereby increasing the potential for a residential fire. Arcing can occur and may lead to fires in these common conditions: pierced insulation on electrical construction wire frayed appliance extension cords loose electrical connections overheated electrical cords and wires The Federal Pioneer AFCI utilizes state-of-the-art digital microprocessor technology that has been coupled with a tab-lok circuit breaker. These devices will disconnect power to the circuit during any of these conditions: short circuit overload arc faults - parallel, line-to-neutral or line-to-ground, or in series on a damaged wire Federal Pioneer AFCI can be installed in any new or existing tab-lok load centre. A15AFI Breaker Handle Colour - Blue A20AFI Breaker Handle Colour - Red tab-lok Generator Panel - Replacement Breakers Catalogue umber Amp Main Breaker Type A3P30GE 30 A3P30 Amp Modular Breaker-Transfer Disconnect A3P60GE 60 A3P60 Amp Modular Breaker-Transfer Disconnect A3P70GE 70 A3P70 Amp Modular Breaker-Transfer Disconnect List Price -40

41 tab-lok Circuit Breakers Recreation Vehicle Park Power Centre - Receptacle Kits Receptacle Kits Description Receptacle Kits for RH102-4CHT One 15A 125V duplex with break-off tabs for separate feed. (Eagle #4270B) Cat. o. K1 One 30A 125V (Eagle #1263) K3 ide blanking plate for RH102-4CHT units. RH1024CHTBRC Receptacle Kits for RH104-8CHT One 15A 125V duplex with break-off tabs for separate feed. (Eagle #4270B) RM15 Two 15A 125V duplex with break-off tabs for (Eagle #4270B) RM A receptacle module kit 1-1 GFI 15A (Hubbell GFR5252) RM15GFI 15A receptacle module kit 2-1 GFI 15A (Hubbell GFR5252) RM1515GFI 20A receptacle module kit 2-1 GFI 20A (Leviton 8899) RM2020GFI One 30A 125V (Eagle #1263) RM30 One 50A 125/250V (Eagle #58) RM50 One 30A 125V and one 15A 125V duplex with break-off tabs for separate feed (Eagle #1263 & #4270B) RM1530 One 30A 125V and one 15A GFI receptacle (Hubbell GFR5252) RM15GFI30 One 125V twist lock 20A (Hubbell #23CM10) 30A (Hubbell #26CM10) RM20TL RM30TL ide blanking plate for RH104-8CHT using non-twist lock receptacle kits. ide blanking plate for RH104-8CHT using twist lock receptacle kits. RM00 RMBLTL -41

42 tab-lok Circuit Breakers Accessories tab-lok Loadcentre Accessories Door Kits, 1 Phase, Type 1 Enclosures OL Reference Loadcentre Catalogue umber Door Kit Catalogue umber DK1W DK2W98 List Price td. Package ize DK3W DK4W DK5W DK8W DK9W98 BE C DK1BEW98 BE C BE C DK2BEW98 DK3BEW98 3 PK6FL BE C BE C DK4BEW98 DK5BEW98 DK3W98 BE C DK6BEW98 BE C DK7BEW98 BE C DK7BEW98 BE C DK8BEW98 BE C DK9BEW98 Main Lug Kits ote: For use with W98 eries tab-lok loadcentres. Max. Bus (A) Main Lug Kit Catalogue umber List Price Door Lock Kits, 1 Phase, Type 1 Enclosures OL Catalogue umber List Price Description PK6FL For use with 125 and 225A W98 eries tab-lok loadcentres. 125A 225A QOL125 QOL225 ote: For use with W98 eries tab-lok loadcentre interior. ingle phase only. Filler Plates Catalogue umber PF1 BFAB Description Filler plate for A or C breakers. For use in present design of tab-lok enclosures, except 400 A - see BFAB. Will also fit previous design using 1/2 metal KO s PF1 consists of 1 strip of 4 1/2 plastic fillers suitable for 4 C poles or 2 A poles. Minimum order quantity 25 Filler plate for 1 A breaker. For use in present 400 A enclosure design and previous enclosure designs using aluminum center strip. Minimum order quantity: 50 List Price PF1 BFAB -42

Loadcentres and Circuit Breakers

Loadcentres and Circuit Breakers Loadcentres and Circuit Breakers quare D Loadcentres and Circuit Breakers election Guide Contents Description Page General Information Breakers Product Illustrations/Features 3-4 tandard Breakers and Tandem

More information

Section 2 HomeLine Loadcentres

Section 2 HomeLine Loadcentres Section 2 HomeLine Loadcentres Features that Outclass the Competition The quality you expect from Schneider Electric, the industry leader, is built into all HomeLine loadcentres. One example is our exclusive

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

QO and HOMELINE Circuit Breaker Load Centers and Enclosures

QO and HOMELINE Circuit Breaker Load Centers and Enclosures QO and HOMELIE Circuit Breaker Load Centers and Enclosures Class 1130, 1131, and 1170 COTET chneider Electric Brands Description Page QO Circuit Breaker Load Centers Class 1130............................

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy SM

Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy SM Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy M Thinking Outside the quare > Who we are chneider Electric total

More information

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35 Circuit Breakers Selection Guide Description Page Selection Information -2 QO and QOU Miniature Circuit Breakers -10 H-Frame J-Frame QO Miniature Circuit Breakers QO Circuit Breaker Accessories QO and

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION MPH66125 with Horn Bypass Square D brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: UL Listed

More information

Main Wire Size AWG/kcmil. Product Catalog # UPC Code QOM22225NS

Main Wire Size AWG/kcmil. Product Catalog # UPC Code QOM22225NS QO Load Centers > Catalog umber uide QO 1 8 16 M 100 T FT C CP Position 1 rand QO = QO HOM = Homeline Position 2 Phases Only applies to QO lank or 1 = ingle 3 = Three Position 3 paces Maximum number of

More information

Section 8 Stab-lok Circuit Breakers

Section 8 Stab-lok Circuit Breakers Section 8 Stab-lok Circuit Breakers Stab-lok easier to work with and faster to install Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique

More information

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application Product Offering and Specificaton Guide Application Main lug loadcentre, b Phase 3 W /V, to 0A, / - 0/80 circuits b 3 Phase W /8V, 00 to 5A, - circuits Main Breaker loadcentre, b Phase 3 W /V, to 0A, /

More information

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35 Circuit Breakers Selection Guide Description Page Selection Information -2 QO and QOU Miniature Circuit Breakers -10 B-Frame H-Frame QO Miniature Circuit Breakers QO Circuit Breaker Accessories QO and

More information

Contents. 4 Loadcentres

Contents. 4 Loadcentres POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

Section 1. Load Centers and Circuit Breakers.  Section Updated 11 / 2014 Section Updated 11 / 2014 Q-Line Circuit Breakers Product Features and Benefits...1-2 PowerMark Gold Load Centers Product Features and Benefits...1-3 PowerMark Gold and Plus Load Centers Product Number

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Retail Products Catalog

Retail Products Catalog Retail Products Catalog www.schneider-electric.us Table of Contents Overview bout Us...4 Product Definitions Types of Circuit Breakers, Residential Load Centers & other Electrical Devices...6 QO Product

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

NF Circuit Breaker Panelboards

NF Circuit Breaker Panelboards Catalog 670CT070 2008 Class 670 COTET Description............................................. Page tandards and Ratings........................................ 3 Main Circuit Breakers.........................................

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at -1 Power Outlet Panels Contents Description Page Surface Units................................................... -3 Pedestal Units.................................................. -3...............................................

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip. Discount Schedule DE2A

Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip. Discount Schedule DE2A OR URRNT INORMTION I I Two-wire SWN New! 2P I Three-wire SWN QO With Shunt Trip K Key Operated QO and Miniature ircuit reakers QO rc-ault ircuit reaker QO arc-fault circuit breakers provide branch feeder

More information

EZ Meter-Pak Meter Centers

EZ Meter-Pak Meter Centers NEMA 3 onstruction Vac Maximum, for use on A systems, suitable for use as ervice Equipment. tility ompany equirements: eview local utility requirements to ensure that metering equipment meets their standards.

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac

More information

5.2. Power Pedestals. Contents Description

5.2. Power Pedestals. Contents Description .2 Power Outlet Panels Contents Description Product Overview......................... Application Description.................. Features and Benefits................... Standards and Certifications..............

More information

Class 730, 731, 733 / Refer to Catalog: 0730CT9801

Class 730, 731, 733 / Refer to Catalog: 0730CT9801 LA CENTES Q Miniature Circuit s Q Plug-n Circuit s Class 730, 73, 733 / efer to Catalog: 0730CT980 www.schneider-electric.us Square brand Q miniature circuit breakers are plug-on products for use in Q

More information

Modular Metering. Canadian Version

Modular Metering. Canadian Version Modular Metering Canadian Version Meter Centres and Tenant Breakers...2 Industrial Multi-Metering...3 Main Service Modules...4 Main Terminal Boxes...7 Main Circuit Breakers...8 Main Fusible Switches...9

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

6.2. Power Pedestals. Contents

6.2. Power Pedestals. Contents Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages FILE: Distribution Product Catalog!!IERVICEB.aJC Power Outlet Panels CONTENTS Description Class Pages Application Data.......................... 1140........ 36 Dimensions................................

More information

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No.

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No. Square D Breakers American International Marketing P.O. Box 9133 Portland OR 97291-033 Closeout #1279-Square-D-Breakers Square D HOM230CP 30A DP Circuit Breaker (NEW) Square D #HOM230CP 30A DP Circuit

More information

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive

More information

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Volume 1 Residential and Light Commercial CA E December Power Pedestals.2 Power Outlet Panels Contents Description Page Product Overview................................. 287 Application Description.......................... 288 Features and Benefits...........................

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

MEG Approval Meter Equipment Group

MEG Approval Meter Equipment Group MEG Approval Meter Equipment Group MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial,

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Selection Information 7-2. QO and QOU Miniature Circuit Breakers Multi 9 TM Miniature Circuit Breakers 7-16

Selection Information 7-2. QO and QOU Miniature Circuit Breakers Multi 9 TM Miniature Circuit Breakers 7-16 Table of Contents Section Miniature and Molded Case Circuit Breakers H-Frame J-Frame Selection Information -2 QO and QOU Miniature Circuit Breakers -10 QO Miniature Circuit Breakers -10 QO Circuit Breaker

More information

1.5 INCH W X 2.91 INCH D X 3 INCH H

1.5 INCH W X 2.91 INCH D X 3 INCH H 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 ax: 936-560-4685 Q0230 QO230 2P-120/240V-30 Square ompany atalog Number Manufacturer escription Weight per unit Product ategory Q0230 Square

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Selection Information 7-2. Motor Circuit Protectors Automatic Switches Vdc Circuit Breakers 7-35

Selection Information 7-2. Motor Circuit Protectors Automatic Switches Vdc Circuit Breakers 7-35 Table of Contents Section Miniature and Molded Case Circuit Breakers H-Frame J-Frame Selection Information -2 QO and QOU Miniature Circuit Breakers -10 QO Miniature Circuit Breakers -10 QO Circuit Breaker

More information

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description .5 Types PRL1a, 2a, a, E, 4 and Column Modifications s Types PRL1a, 2a, a, E, 4, Column Modifications Selection Guide Modifications Alphabetical Index Modification Item Contents Types PRL1a, 2a, a, E,

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

CIRCUIT BREAKER PANELBOARDS

CIRCUIT BREAKER PANELBOARDS CIRCUIT BREAKER PANELBOARDS Class l, ones 1 & 2, Groups llb+h 2 Certified File LR 11713 for B7L FEATURES-SPECIFICATIONS Applications Hazardous locations due to the presence of flammable gases or vapors,

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

THQL1120AF2 THQL1120AF2 Arc Fault BRKR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit reaker Selection Guide T H L 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC L = Plug-in

More information

POWER PRODUCT Meter Centres Contents

POWER PRODUCT Meter Centres Contents POWER PRODUCT Meter Centres Contents General Specifications - Catalogue Numbering System - 40V Meter Centre Overview - Features & Benefits -3 Procedure -5 Switches and Tap Boxes -6 Meter Stacks -7 Socket

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

Indiana Meter Mounting Equipment

Indiana Meter Mounting Equipment Indiana Meter Mounting Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

Panelboards Ready To Install (RTI)

Panelboards Ready To Install (RTI) Panelboards Ready To Install (RTI) Selection Guide Contents Description Page NQ - 240 Volt Lighting and Distribution Panelboard QO - Plug On Branch Breakers 2-3 QOB - Bolt On Branch Breakers 4 QO/QOB Branch

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Retail Reference Guide

Retail Reference Guide www.usa.siemens.com/retail Retail Reference Guide Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI) uses advanced electronic technology

More information

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear 13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of

More information

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION Lighting Panelboards EPLU and D2LU Series Installation & Maintenance Information APPLICATION EPLU and D2LU Series panelboards provide a centrally controlled switching system and short circuit protection

More information

Microlectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units

Microlectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units Microlectric CO Series Meter sockets A complete family of combination meter sockets and breaker units Outdoor, above-ground main breaker access increases safety Table of Contents Introduction... 3 Microlectric

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

PANELBOARDS SECTION 1

PANELBOARDS SECTION 1 SECTION 1 P1 PANELBOARDS Description Page General Information 1-2 Selection and Application 1-2 Application 1-3 1-6 Main Breaker Panel Size Selector 1-3 Main Breaker Selection 1-3 Main Lugs Size Selector

More information

Engine Generator Circuit Breakers

Engine Generator Circuit Breakers Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................

More information

22,000 A IR Catalog Number QA115AFCH QA120AFCH Q215AFCH Q220AFCH. 65,000 A IR Catalog Number QA115AFCHH QA120AFCHH QA115AFH QA120AFH

22,000 A IR Catalog Number QA115AFCH QA120AFCH Q215AFCH Q220AFCH. 65,000 A IR Catalog Number QA115AFCHH QA120AFCHH QA115AFH QA120AFH 06/3/4 Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to

More information

Division 1 Explosionproof Panelboards

Division 1 Explosionproof Panelboards Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting

More information

Meter Mounting Equipment Wisconsin Area

Meter Mounting Equipment Wisconsin Area Meter Mounting Equipment Wisconsin Area MILBANK OVERVIEW MILBANK OVERVIEW Charles A. Milbank 879-9 Bill Martin 9-998 Robert F. Waldrop 9-00 Robert F. Waldrop, II Chairman Katrina Waldrop Henke Vice Chairman

More information

I-Line Circuit Breaker Panelboards Catalog 2110CT9701R02/ Class 2110

I-Line Circuit Breaker Panelboards Catalog 2110CT9701R02/ Class 2110 I-Line ircuit Breaker Panelboards atalog 2110T9701R02/16 2016 lass 2110 ONTENTS Description............................................ Page Product Description.................................... Page

More information

22.000A IR. Catalog Number. Price $

22.000A IR. Catalog Number. Price $ Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

Underwriters Laboratories Inc. Marking Guide. Molded Case Circuit Breakers. 600 Volts or Less April 2002

Underwriters Laboratories Inc. Marking Guide. Molded Case Circuit Breakers. 600 Volts or Less April 2002 Underwriters Laboratories Inc. Marking Guide Molded Case Circuit Breakers 600 Volts or Less April 2002 59 *UL has developed the Molded-Case Circuit Breaker Marking Guide to assist AHJs and installers in

More information

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com J QMB Panel boards Switchboards 200,000A. short circuit rating QMB Fusible Switches Throughout our complete line of 30-SOOA. ULiisted QMB fusible switches, we've combined timeproven Square D safety switches

More information

Duke/MEG Approval Meter Equipment Group

Duke/MEG Approval Meter Equipment Group Duke/MEG Approval Meter Equipment Group Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank provides

More information

Modular Metering Application Guide

Modular Metering Application Guide GE Energy Connections Modular Metering Application Guide Mini Mod* III Product Family Table of Contents Page No. Nomenclature 3 Mini Mod III Photos 4 Mini Mod III Ring -Type and Ringless 5 Mini Mod III

More information

SynergEX Panelboards for Hazardous Locations

SynergEX Panelboards for Hazardous Locations SynergEX Panelboards for Hazardous Locations Installation & Maintenance Information 1. APPLICATION SynergEX panelboards provide short circuit protection for feeder or branch circuits to control lighting,

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Selection Guide Contents Descriptions Page General Information Features and Benefits 2-3 Product Illustrations General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Heavy Duty Safety

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Lighting Panelboards. P2 Panelboards

Lighting Panelboards. P2 Panelboards Lighting Panelboards P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled options to meet virtually any lighting panel application. The

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information