Selection Information 7-2. QO and QOU Miniature Circuit Breakers Multi 9 TM Miniature Circuit Breakers 7-16

Size: px
Start display at page:

Download "Selection Information 7-2. QO and QOU Miniature Circuit Breakers Multi 9 TM Miniature Circuit Breakers 7-16"

Transcription

1 Table of Contents Section Miniature and Molded Case Circuit Breakers H-Frame J-Frame Selection Information -2 QO and QOU Miniature Circuit Breakers -10 QO Miniature Circuit Breakers -10 QO Circuit Breaker ccessories -12 QO and Multi 9 TM Mounting Bases -13 QOU Miniature Circuit Breakers and QYU Supplementary Protectors -14 QOU ccessories -15 Multi 9 TM Miniature Circuit Breakers -16 PowerPact Molded Case Circuit Breakers -21 D-Frame PowerPact Family -21 H- and J-Frame Circuit Breakers -22 G- and Q-Frame Circuit Breakers -24 D- and M-Frame Circuit Breakers -25 P-Frame Circuit Breakers -26 R-Frame Circuit Breakers -2 Motor Circuit Protectors -28 PowerPact H- and J-Frame Electronic Motor Circuit Protectors -28 H-Frame and J-Frame MCP Selector -29 Mag-Gard Motor Circuit Protectors (MCP) -30 GJ-, L-, and M-Frame MCP Selection -31 Motor Protection Selection Tables -32 M-Frame P-Frame utomatic Switches Vdc Circuit Breakers -34 Mission Critical Circuit Breakers -35 PowerPact Circuit Breaker ccessories -36 Micrologic Electronic Trip Units -43 Masterpact Universal Power Circuit Breakers -45 Ground-fault Protection -46 Molded Case Circuit Breakers -49 F-Frame Thermal-magnetic Circuit Breakers -49 K- and Q4-Frame Thermal-magnetic Circuit Breakers -49 L-Frame Thermal-magnetic Circuit Breakers -51 L-Frame Electronic Trip Circuit Breakers -51 Micrologic Series B Trip Unit ccessories -52 Dimensions and Shipping Weights -54 R-Frame Circuit Breaker Enclosures Schneider Electric -1 This document provided by Barr-Thorp Electric Co., Inc

2 Selection Information Miniature Circuit Breakers Class 500, HOM Circuit Breakers QO Circuit Breakers Circuit Breaker Type Plug-on HOM HOM- FI HOM- GFI HOM- EPD HOMT QO QO-H QO-VH QH QOT QO- CFI Bolt-on QOB QOB-H QOB-VH QHB QOB- CFI QO- VHFI QOB- VHFI QO-GFI QOB-GFI QO- VHGFI QOB- VHGFI QO-EPD QO-EPE QOB-EPD QOB-EPE Unit Mount Number of Poles ,3 a 1, Current Range Interrupting s UL/CS (k) (50/60 Hz) DC s IEC (50/60 Hz)g Special s Fed. Specs W-C-35B/GEN Other Standard m b m Vac /240 Vac Y/ Vac d e Vac 480Y/2 Vac 48 Vdc 5f 5 f 5 f 60 Vdc 65 Vdc 125 Vdc 250 Vdc IEC (Icu) ccessories and Modifications X X X X X X X X X X X X X X X HCR h NOM HCR h HCRi NOM HCR i HCR i NOM NOM Shunt Trip j X X X X X X X X X k X X X Undervoltage Trip uxiliary Switches j X X X X X X X X X k X X X X X X X X X X X larm Switch j X X X X X X X X X k X X X X X X X X X X X Handle Operators Handle Padlock ttachment Trip System Type X X X X l X X X X X X X X X X X X X X X X X X X X X Thermal-magnetic X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Molded Case Switch X X X Dimensions (1P Unit Mount) Dimensions (1P Unit Mount) in. (mm) Height 3.13 (9) 3.5 (89) a 4.5 (121) 4.12 (103) Width 1.00 (25) 0.5 (19) a Depth 2.98 (6) 2.92 (4) a Pages Page 1-13 Pages -10, -11 a See page -54 for dimensions for: QOB2150VH, QOB3110VH, QOB3125VH and QOB3150VH. b HOMT tandem is 30 maximum. HOMT quad tandem has 20 maximum on outside poles, and 50 maximum on the inside poles. c FI, EPD and GFI products are rated 60 Hz only. d See the Supplemental Digest for 3Ø corner grounded systems. e Vac for 3P only. f 1P and 2P, 10 0 and 3P only. g See the Supplemental Digest for circuit breakers with IEC ratings. h HCR on HOM 1P and 2P i HCR on QO, QOB 1P 10 0, 2P , 3P ; QOB-VH 1P 15 0, 2P , 3P j Factory-installed option only k Factory-installed accessories are not available on QOB-VH 2P150 and 3P l Handle padlock attachment available for HOMT quad tandem only. m 2P requires 4P width Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

3 Selection Information Miniature Circuit Breakers Class 500, 600 QOU Circuit Breakers QOM1 and QOM2 Main Circuit Breakers Multi 9 Circuit Breakers and Supplementary Protectors EDB Circuit Breakers Circuit Breaker Type Plug-on Bolt-on QOM1-VH QOM2-VH EDB EGB EJB Unit Mount QOU QYUa UL 489 C60N UL10 C60Nb C60H-DC Number of Poles , ,3 1 2,3 1 2,3 New! Current Range Interrupting s UL/CS (k RMS) (50/60 Hz) DC s IEC (50/60 Hz) Icu Special s Vac /240 Vac Vacc Vac Y/2 Vac Vdc 5d 5d 5d Vdc 5e 5e 5e Vdc Vdc Vdc Vdc 5k 240 Vac Vac Fed. Specs X X X X X X X X X X X X X X X W-C-35B/GEN Other Standard HCR f g HCR ccessories and Modifications Shunt Trip Xh Xh Xh Xh X h X X X X X X X X X h X h X h X h X h X h Undervoltage Trip X X X X X X X X uxiliary Switches Xh Xh Xh Xh X X X X X X X X Xh Xh Xh Xh Xh Xh larm Switch Xh Xh Xh Xh X X X X X X X X Xh Xh Xh Xh Xh Xh Handle Operators X X X X X X X X Handle Padlock ttachment X X X X X X X X X X X X X X X X X X X X Trip System Type Thermal-magnetic X X X X X X X X X X X X X X X X X X X X Molded Case Switch X X Dimensions (1P Unit Mount) Dimensions (1P Unit Mount) in. (mm) Height 4.05 (103) 5.09 (129)i 5.60 (142)i 4.21 (10)j 3.19 (81) 3.19 (81) 5.66 (144) Width 0.5 (19) 5.00 (12)i 5.0 (129)i 0.1 (18) 0.1 (18) 0.1 (18) 1.42 (36) 0.98 (25) Depth 2.92 (4) 3.4 (88)i 3.60 (91)i 2.6 (0) 2.6 (0) 2.56 (65) 4.05 (103) Pages Pages -14 Pages 1-2 Pages -16 through -19 Page 9-1 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a QYU is a UL 10 supplementary protector. b C60N are recognized components per UL 10. c For information regarding 3Ø corner grounded systems see the Supplemental Digest. d 1P and 2P, 10 0 and 3P only. e QOU is UL Listed for 60 Vdc per pole , 1P; , 2P; and 0 100, 3P. f HCR on QOU 1P and 3P , 2P ; g UL 489 for DC Telecom applications (1-pole only). h Factory-installed option only i QOM1 and QOM2 dimensions are for 2-pole unit. j 480 V C60 height is 5.56 in. (141 mm). k 2 poles must be wired in series for 500 Vdc Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

4 Selection Information PowerPact 100 Frame PowerPact 150 H-Frame Molded Case Circuit Breakers Class 500, 600, Frame Circuit Breaker Type GJL HD HG HJ HL F (240 V) F FH FHb FH Number of Poles 3 2,3 2,3 2,3i 2,3i 1, 2, 3 1 2, , 3 Current Range Interrupting s UL/CS/NOM (k RMS) (50/60 Hz) DC s IEC (k RMS) Icu/lcsd IEC 50/60 Hz Special s 240 Vac k 25k Y/2 Vac Vac Y/34 Vac Vac Vdc c 10c 10 10c 10c Vdca Vac 65/65 25/25 65/65 100/ /125 18/9 18/9 415 Vac 65/65 18/18 35/35 65/65 100/100 10/2.5 10/2.5 10/2.5 10/2.5 10/2.5 10/2.5 For additional IEC ratings, see the Supplemental Digest. Fed. Specs W-C-35B/GEN X X X X X X X X X X HCR (2P, 3P) X X X Connections/Terminations Unit Mount X X X X X X I-Line X X X X X X X X X Rear Connection Xh Xh X X X X X Drawout Xh Xh X X Optional Lugs Xh Xh X X X X X X X ccessories and Modifications Shunt Trip X X X X X Xfe Xf Xf Undervoltage Trip X X X X X Xfe Xf Xf uxiliary Switches X X X X X Xfe Xf Xf larm Switch X X X X X Xfe X f Xf Xf Xf Xf Motor Operator Xh Xh X X X X Handle Operators X Xh Xh X X X X X X X Mechanical Interlocks (3P) X X X X X X Handle Padlock ttachment X Xh Xh X X X X X X X X Cylinder Lock (3Pf) Xh Xh X X X X Handle Mechanical Interlocks Xh Xh X X Optional GF Protectiong X X Trip System Type Thermal-magnetic X X X X X X X X X X X Instantaneous-only (MCP) X Xj Xj X X Molded Case Switch X X X X X Electronic Enclosures (Pages ) General Purpose (NEM 1) X X X X X X X X X X Raintight (NEM 3R) X X X X X X X X X X Dust-tight (NEM 12) X X X X X X X X X X Watertight (NEM 4, 4X, 5) X X X X X X X X X X Explosion Proof (NEM, 9) X X X X X X Dimensions (3P Unit Mount) in. (mm) Height 4.2 (120) 6.4 (163) 6 (152) 6 (152) Width 3.54 (90) 4.1 (104) 4.5 (114) 4.5 (114) Depth 3.94 (100) 3.4 (86) 4.13 (105) 4.13 (105) Pages (Unit Mount)/(I-Line) Page -24 Pages -22, -23, -28, -33/9-25 Pages -49,/9-23 Pages -49/9-24 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. f Factory-installed option only. a Ungrounded UPS systems only. See page -34. b 65 Vac c 1Ø 125 Vdc rating only. d Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. g Requires factory-installed G Shunt trip and 3P module. h Not available in HD and HG 2P rating (2P module). i 2P in a 3P module. j 3P only. k 1P F is 120 Vac. e Not available on 1P F (240 V) Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

5 Selection Information Molded Case Circuit Breakers Class 500, 600, F-Frame PowerPact 250 J-Frame PowerPact 250 Q-Frame Circuit Breaker Type FI FY JD JG JJ JL QB QD QG QJ Number of Poles 2, 3 1 2,3a 2,3a 2,3a 2,3a 2, 3 2, 3 2, 3 2, 3 Current Range b 0 250b 0 250b 0 250b Interrupting s UL/CS/NOM (k RMS) (50/60 Hz) DC s IEC (k RMS) Icu/lcsd IEC 50/60 Hz Special s 240 Vac Y/2 Vac Vac Y/34 Vac Vac Vdc Vdcc Vac 25/25 65/65 100/ /125 10/5 10/5 10/5 10/5 415 Vac 6/1.5 18/18 35/35 65/65 100/100 10/5 10/5 10/5 10/5 For additional IEC ratings, see the Supplemental Digest. Fed. Specs W-C-35B/GEN X X X X X X X X X HCR (2P, 3P) X X X X X X X Connections/Terminations Unit Mount X X X X X X X X X I-Line X X X X X X X X X X Rear Connection X X X X Drawout X X X X Optional Lugs X X X X X ccessories and Modifications Shunt Trip Xf X X X X Undervoltage Trip Xf X X X X uxiliary Switches Xf X X X X larm Switch Xf X X X X Motor Operator X X X X X Handle Operators X X X X Mechanical Interlocks (3P) X X X X X X X X Handle Padlock ttachment X X X X X X X X X X Cylinder Lock (3Pf) Optional GF Protectione X Trip System Type Thermal-magnetic X X X X X X X X X X Instantaneous-only (MCP) Xg Xg Molded Case Switch (utomatic) X X X X X Electronic Enclosures (Pages ) General Purpose (NEM 1) X X X X X X X X Raintight (NEM 3R) X X X X X X X X Dust-tight (NEM 12) X X X X Watertight (NEM 4, 4X, 5) X X X X Explosion Proof (NEM, 9) Dimensions (3P Unit Mount) in. (mm) Height 8 (203).5 (191) 6.4 (164) Width 4.5 (114) 4.1 (104) 4.5 (114) Depth 4.5 (121) 3.4 (86) 3.93 (100) Pages (Unit Mount)/(I-Line) Pages -49/9-24 Pages -22, -23, -28, -33, -34/9-25 Pages -24/9-24 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a 2P in a 3P module b I-Line Q-frame circuit breakers are available only. 250 Q-frame unit-mount circuit breakers are limited to Cu conductors only. c Ungrounded UPS systems only. See page -34. Special DC J-Frame only. d Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. e Requires factory-installed G shunt trip and 3P module. f Factory-installed option only. g 3P only Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

6 Selection Information Molded Case Circuit Breaker Class 500, 600, K-Frame PowerPact 400/600 D-Frame 400 L-Frame 600 L-Frame Circuit Breaker Type KI DG DJ DL Q4 L LH LC LI Number of Poles 2, 3 3, 4 3, 4 3, 4 2,3 2,3 2, 3 2, 3 2, 3 Current Range Interrupting s UL/CS/NOM (k RMS) (50/60 Hz) DC s IEC (k RMS) Icu/lcsb IEC 50/60 Hz Special s 240 Vac Y/2 Vac Vac Y/34 Vac Vac Vdc Vdca Vac 85/85 100/ / Vac 130/65 45/45 0/0 150/150 20/5 20/5 65/65f For additional IEC ratings, see the Supplemental Digest. For additional IEC ratings, see the Supplemental Digest. Fed. Specs W-C-35B/GEN X X X X X X HCR (2P, 3P) X X X X X Connections/Terminations Unit Mount X X X X X X X X X I-Line X X X X X X Rear Connection X X X X X X Drawout X X X Optional Lugs X X X X X X X X X ccessories and Modifications Shunt Trip Xc X X X X X X X X Undervoltage Trip Xc X X X X X X X X uxiliary Switches Xc X X X X X X X X larm Switch Xc X X X X X X X X Motor Operator X X X X X X X Handle Operators X X X X X X Mechanical Interlocks (3P) X X X Xd Xd Handle Padlock ttachment X X X X X X X X X Cylinder Lock (3P) X X X Optional GF Protection Xe X X X Trip System Type Thermal-magnetic X X X X X X Instantaneous-only (MCP) X X X X X Molded Case Switch (utomatic) X X X X Electronic X X X Enclosures (Pages ) General Purpose (NEM 1) X X X Raintight (NEM 3R) X X X X Dust-tight (NEM 12) X X X X X X Watertight (NEM 4, 4X, 5) X X X X Explosion Proof (NEM, 9) Dimensions (3P Unit Mount) in. (mm) Height 8 (203) (340) 11 (29) (301) Width 4.5 (114) 5.51 (140) 6 (152).5 (190) Depth 4.5 (121) 4.33 (110) 5.84 (148) 6.4 (11) Pages Pages (Unit Mount)/(I-Line) Pages -25/-33 Pages -51/9-2 Pages -51/ /9-26 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a Ungrounded UPS systems only. See page -34. b Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. c Factory-installed option only. d Requires circuit breaker with WB suffix. e Requires factory-installed G Shunt trip. vailable only for 3P. f 65/50 k Icu/Ics for ratings Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

7 Selection Information Molded Case Circuit Breakers Class 600, 612, L-Frame PowerPact 800 M-Frame PowerPact 1200 P-Frame 1000 M-Frame Circuit Breaker Type LX LXI LE MG MJ PG PJ PK PL M MH MX ME Number of Poles , 3 2, 3 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3 2, Current Range Interrupting s UL/CS/NOM (k RMS) (50/60 Hzb) DC s IEC (k RMS) Icu/lcsc IEC 50/60 Hz Special s 240 Vac Y/2 Vac Vac Y/34 Vac Vac Vdc Vdca Vac 50/25 65/35 50/25 65/35 50/25 125/ Vac 65/65f 65/65f 35/20 50/25 35/20 50/25 50/25 85/45 30/30 65/33 65/33 65/33 For additional IEC ratings, see the Supplemental Digest. For additional IEC ratings, see the Supplemental Digest. Fed. Specs W-C-35B/GEN X X X X X X X X X X X X X HCR (2P, 3P) X X X X X X X X Connections/Terminations Unit Mount X X X X X X X X X X X X X I-Line X X X X X X X X X X X X X Rear Connection X X Drawout Xe Xe Xe Xe Optional Lugs X X X X X X X X X X X X X ccessories and Modifications Shunt Trip X X X X X X X X X X X Xe Xe Undervoltage Trip X X X X X X X X X X X Xe Xe uxiliary Switches X X X X X X X X X X X Xe Xe larm Switch X X X X X X X X X X X Xe Xe Motor Operator Xe Xe Xe Xe X X Handle Operators Xe Xe Xe Xe X X X X Mechanical Interlocks (3P) X X X X Xd Xd Handle Padlock ttachment X X X X X X X X X X X X X Cylinder Lock (3P) X X X X Optional GF Protection Xe Xe Xe X X X X Xe Xe Trip System Type Thermal-magnetic X X Instantaneous-only (MCP) X X X X Molded Case Switch (utomatic) X X X X X Electronic X X X X X X X X X X X Enclosures (Pages ) General Purpose (NEM 1) X X X X X X X X X X Raintight (NEM 3R) X X X X X X X X X X Dust-tight (NEM 12) X X X X X X X X X X X X X Watertight (NEM 4, 4X, 5) X X X X X X Explosion Proof (NEM, 9) Dimensions (3P Unit Mount) Note: Height in. (mm) (301) (325) (413) 14 (356) Widthin. (mm).5 (190) 8.30 (210) 8.30 (210) 9 (229) Depthin. (mm) 6.4 (11) 8.10 (205) 8.10 (205) 6.5 (165) Pages (Unit Mount)/(I-Line) Page -52/9-28 Page -25/9-28 Page -26, -30, -33/9-29 Supplemental Digest Section 3 ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a Ungrounded UPS systems only. See page -34. b UL PowerPact MG/MJ and PG/PJ/PK/PL are 60 Hz only. c Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. d Requires breaker with WB suffix e Factory-installed option only. f 65/50 k Icu/Ics for ratings Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

8 Selection Information Molded Case Circuit Breakers Class 600, 612, N-Frame 2000 P-Frame 2500 P-Frame PowerPact 3000 R-Frame Circuit Breaker Type N NC NX NE P PH PC PX PE RG RJ RK RL Number of Poles 2, 3 2, , 3 2, 3 2, , 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 Current Range Interrupting s UL/CS/NOM (k RMS) (50/60 Hz) DC s IEC (k RMS) Icu/lcsb IEC 50/60 Hz Special s 240 Vac Y/2 Vac Vac Y/34 Vac Vac Vdc 500 Vdca Vac 50/25 65/35 85/65 125/ Vac 50/25 0/35 0/35 0/35 50/38 0/53 0/53 0/53 0/53 35/20 50/25 0/55 85/45 For additional IEC ratings, see the Supplemental Digest. Fed. Specs W-C-35B/GEN X X X X X X X X X X X HCR (2P, 3P) X X X X Connections/Terminations Unit Mount X X X X X X X X X X X X X I-Line X X X X Xd Xd Xd Xd Rear Connection Drawout Optional Lugs X X X X X X X X X X X X X ccessories and Modifications Shunt Trip X X X X X X X X X X X X X Undervoltage Trip X X X X X X X X X X X X X uxiliary Switches X X X X X X X X X X X X X larm Switch X X X X X X X X X X X X X Motor Operator X X X X X Handle Operators X X X X Mechanical Interlocks (3P) Handle Padlock ttachment X X X X X X X X X X X X X Cylinder Lock (3P) Optional GF Protection Xc Xc X c X c X X X X Trip System Type Thermal-magnetic X X X X X Instantaneous-only (MCP) X X Molded Case Switch (utomatic) X X X X X X X Electronic X X X X X X X X Enclosures (Pages ) General Purpose (NEM 1) X X X X X Raintight (NEM 3R) X X X X X X X X Dust-tight (NEM 12) X X X Watertight (NEM 4, 4X, 5) Explosion Proof (NEM, 9) Dimensions (3P Unit Mount) Note: Height in. (mm) (308) (510) 26.1 (663) (510) 15 (381) Width in. (mm) 15 (381) 13. (348) 23.3 (592) 13. (348) (420) Depth in. (mm) 8.0 (205) 10.4 (266) (420) 10.4 (266) (366) Pages (Unit Mount)/(I-Line) Supplemental Digest Section 3 Supplemental Digest Section 3 Page -2, -33/9-30 ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a Ungrounded UPS systems only. See page -34. b Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. c Factory-installed option only. d 1000 and 1200 only Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

9 Selection Information Insulated Case Circuit Breakers Class 600, 800 Masterpact 1200 Masterpact 6000 Circuit Breaker Type NT-N NT-H NT-L1 NT-L NT-LF a NW-N NW-H NW-L NW-LF a NW-H NW-L NW-H NW-L Number of Poles 3, 4 3, , 4 3, , 4 3 3, 4 3 Current Range Interrupting s 240 Vac UL/CS/NOM (k RMS) (50/60 Hz) DC s IECb (k RMS) Icu/Ics Special s 480Y/2 Vac Vac Y/34 Vac Vac Vdc 500 Vdc 240 Vac 415 Vac Fed. Specs W-C-35B/GEN HCR (2P, 3P) Connections/Terminations Unit Mount X X X X X X X X X X X X X I-Line Rear Connection X X X X X X X X X X X X X Drawout X X X X X X X X X X X X X Optional Lugs ccessories and Modifications Shunt Trip X X X X X X X X X X X X X Undervoltage Trip X X X X X X X X X X X X X uxiliary Switches X X X X X X X X X X X X X larm Switch X X X X X X X X X X X X X Motor Operator X X X X X X X X X X X X X Handle Operators Mechanical Interlocks X X X X X X X X X X X X X Padlock ttachment X X X X X X X X X X X X X Cylinder Lock Optional GF Protection X X X X X X X X X X X X X Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch (utomatic) X X X X X X X X X X X X X Electronic X X X X X X X X X X X X X Enclosures General Purpose (NEM 1) Raintight (NEM 3R) Dust-tight (NEM 12) Watertight (NEM 4, 4X, 5) Explosion Proof (NEM, 9) Dimensions (3P Unit Mount) in. (mm) Height 12.6 (322) 1.28 (439) 1.28 (439) 1.28 (439) Width (286) 1.4 (450) 1.4 (450) (86) Depth (331) (46) (46) (46) Pages Page -45 and Catalog 0613CT0001 Page -45 and Catalog 0613CT0001 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a Tested to show arc flash hazard risk category as reference by NFP0E. b See Catalog 0613CT0001 for additional ratings and other information Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

10 QO and QOU Miniature Circuit Breakers QO Miniature Circuit Breakers Class 30, 31, 33 / Refer to Catalog 030CT QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD panelboards, NQOD OEM interiors or Speed-D switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD panelboards or interiors.a The QO exclusive Qwik-Open mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15 and 20 QO circuit breakers. QO 1P Table.1: Plug-On Circuit Breakers Table.2: QO-QOB Ring Terminal s b 1P120/240 Vac 2P120/240 Vac Common Trip 2P240 Vacc Common Trip 3P240 Vac Common Trip (20% dder)factory Installed Only Poles Suffix 10 k IR , 2, QO QO QO ,2 15 QO115de QO215d 6.00 QO215H QO315d QO120de QO220d 6.00 QO220H QO320d QO125d QO225d 6.00 QO225H QO325d QO130d QO230d 6.00 QO230H QO330d Space Required 35 QO135d QO235d 6.00 QO335d Table.3: Wire Sizesb QOT 1P Tandem 40 QO140d QO240d 6.00 QO240H QO340d Circuit Breaker Wire Size 45 QO145d QO245d 6.00 QO345d Type (WG/kcmil) 50 QO150d QO250d 6.00 QO250H QO350d l/cu 60 QO160d QO260d 6.00 QO260H QO360d QO (2) Cu 1P 0 QO10d 6.00 QO20d QO20H QO30d l/cu 80 QO280d QO280H QO380d l/cu 90 QO290d QO290H QO390d (2) Cu QO 100 QO2100d QO2100H QO3100d P l/cu 110 QO2110d /0 l/cu 1 Space Required 125 QO2125d l/cu QO 2P 150 QO2150dfk l/cu, (2) Cu QO 15 QO215dfk l/cu 3P 200 QO2200dfk /0 l/cu Molded Case Switch 60 max. 240 Vac QO QO QOB-VH l/cu Molded Case Switch 100 max. 240 Vac QO2000i QO3000i QOT l 14 8 Cu 2 Spaces Required QO2200 2P Spaces Required QO 3P 3 Spaces Required 22 k IRd QO-FI, QO-GFI & QO-EPD l 14 8 Cu 15 QO115VHe QO215VHg QO315VHg , 50, l 14 6 Cu 20 QO120VHe QO220VHg QO320VHg QO-PL l 14 2 Cu 25 QO125VH 3.00 QO225VHg QO325VHg QO130VH 3.00 QO230VHg QO330VHg Table.4: QOT Tandem Circuit 40 QO240VHg QO340VHg Breakers 50 QO250VHg QO350VHg b d 60 QO260VHg QO360VHg P120/240 Vac 0 QO20VHg QO30VHg & 15 QOT QO280VHg QO380VHg & 20 QOT QO290VHg QO390VHg & 20 QOT QO2100VHgh QO3100VHg P120/240 Vac 110 QO2110VHgh Order two QOT1515 or QOT2020 circuit breakers and handle tie QOTHT for common switching of center two poles. 125 QO2125VHgh QO2150VHfgk QO215VHfgk QO2200VHfgk Table.5: Replacement Tandem 42 k IRd 40 QOH240i QOH245i Circuit Breakers For Use in Old Style Non-Class CTL QO Load Centers10 k IR 50 QOH250i b d 60 QOH260i P120/240 Vac1 Space Required 0 QOH & 15 QO QOH & 20 QO QOH & 20 QO QOH & 30 QO QOH2110i & 20 QO QOH Two 1P Individual Trip120/240 Vac2 Spaces Required 65 k IRd 15 & 15 Order Two QO1515 or QO2020 circuit breakers and handle tie QOTHT for 15 QH115e QH QH315d & 20 common switching of center two poles. 20 QH120e QH QH & QH125i QH225i QH325i & 30 QO j QH QH QH & 20 a See Digest Section 1 for load centers, and Section 9 for panelboards and interiors. b circuit breakers are suitable for use with 60 o C or 5 o C conductors circuit breakers are suitable for use with 5 o C conductors. QOT Tandem Circuit limiting QOT c UL Listed 5 k IR on corner grounded Delta systems. tandem circuit d UL Listed as HCR type for use with air conditioning, heating and refrigeration equipment having motor breakers have a group combinations and marked for use with HCR type circuit breakers. mounting cam as shown. Installation e UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. into a QO load center f Requires four spaces (1 WG 300 kcmil l/cu.) Suitable for switching 120 Vac fluorescent lighting loads. can only be made in g UL Listed for use ahead of QO, QO-GFI, QO-EPD, QO-FI, QOT,QOCFI, and QO-PL 10 k IR circuit those positions breakers to permit their application at 22 k fault level. having a mounting h 100 maximum branch mounted opposite. Mounting Cam pan rail slot. Meets i Order only. Contact your local Field Office. Rail Bead Paragraph of j Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT. the NEC. UL Listed Pan Rail Slot as Class CTL k Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 or greater. Interrupting s Page -2 ccessories Page -12 Dimensions Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

11 1P QO-FI 1P QO-GFI 3P QO-GFI 2P QO-GFI Two-wire QO-SWN Three-wire QO-SWN QO 1P With Shunt Trip QO-K Key Operated QO and QOU Miniature Circuit Breakers QO rc-fault Circuit Breaker QO arc-fault circuit breakers provide branch feeder protection for series and parallel-type arcing as required by the NEC and local code adoption, and comply with UL1699. Table.6: Circuit Breaker Type Combination rcfault Interrupter QO rc Fault Circuit Breakersa QO-GFI Qwik-Gard circuit breakers provide overload and short circuit protection, combined with Class ground fault protection. Class denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 m or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. Table.: c 1P 120 Vac 1P 120 Vac 10 k IR 22 k IR 1 Space Required 1 Space Required 15 QO115CFI QO115VHCFI QO120CFI QO120VHCFI QO-GFI Circuit Breakers Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 1P 120 Vac 2P Common Trip 120/240 Vac QO-EPD/EPE QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 milliampere level (EPD) or 100 milliamp level (EPE). They are not designed to protect people from electrical shock. QO-SWN Switch Neutral Common Trip 2008 NEC P Common Trip 208Y/120 Vac 10 k IR 22 k IR 10 k IR 10 k IR 1 Space Required $ Price 1 Space Required 2 Spaces Required $ Price 3 Spaces Required $ Price $ Price 15 QO115GFI 233. QO115VHGFI 482. QO215GFI 413. QO315GFI QO120GFI 233. QO120VHGFI 482. QO220GFI 413. QO320GFI QO125GFI 233. QO125VHGFI 482. QO225GFI QO130GFI 233. QO130VHGFI 482. QO230GFI 413. QO330GFI QO240GFI 413. QO340GFI QO250GFI 413. QO350GFI QO260GFId 413. Table.8: c 1P 120 Vac QO-EPD Circuit Breakers 2P Common Trip 120/240 Vac 3P Common Trip 240 Vac 10 k IR 10 k IR 10 k IR 1 Space Required $ Price 2 Spaces Required 3 Spaces Required $ Price $ Price $ Price 15QO115EPD 410. QO215EPD 660. QO315EPDe10. QO315EPEe10. 20QO120EPD 410. QO220EPD 660. QO315EPDe10. QO315EPEe10. 25QO125EPD 410. QO225EPD QO130EPD 410. QO230EPD 660. QO315EPDe10. QO315EPEe QO240EPD 660. QO315EPDe10. QO315EPEe QO250EPD 660. QO315EPDe10. QO315EPEe QO260EPDd 660. Table.9: c QO-SWN Circuit Breakers New! New! 2 Wire 120 Vac 3 Wire 120/240 Vac 10 k IR 10 k IR 2 Spaces Required 3 Spaces Required 10 QO210SWN QO215SWN QO315SWN QO220SWN QO320SWN QO225SWN QO230SWN QO330SWN QO240SWN QO340SWN QO250SWN QO350SWN QO Miniature Circuit Breakers Class 685, 690, 30, 912, 950 / Refer to Catalog 030CT9801 QO-HID HID circuit breakers are for use on circuits feeding fluorescent and high intensity discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. Table.10: c QO-HID Circuit Breakers 1P 120/240 Vac 2P Common Trip 120/240 Vac 3P Common Trip 240 Vac 10 k IR 10 k IR 10 k IR 1 Space Required 2 Spaces Required 3 Spaces Required 15 QO115HIDb QO215HID 8.00 QO315HID QO120HIDb QO220HID 8.00 QO320HID QO125HID QO225HID 8.00 QO325HID QO130HID QO230HID 8.00 QO330HID QO140HID QO240HID QO150HID QO250HID 8.00 QO-K Key operated QO circuit breakers are available in singlepole construction and can be mounted in any single-pole space which will accept a standard QO. These circuit breakers can be turned ON or OFF or to RESET with a special key (catalog number QOK10) included with the circuit breaker. These circuit breakers are UL Listed and available as shown in the table. Table.11: QO-K Circuit Breakers 120 Vac10 k IR (1 Space Required) c 10 QO110K QO115K QO120K QO130K QO-HM High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table.12: QO-HM Circuit Breakers c Cat. No Non-automatic (Standard) Miniature Switches Miniature non-automatic switches have the same physical packaging as miniature circuit breakers, but open only when the handle is switched to the OFF position. Non-automatic switches provide no overcurrent protection or short circuit protection. They must not be used on systems that have an available fault current greater than the values listed in the table. Non-automatic switches are UL Listed per UL 108 and are CS certified. Table.13: QO Non-utomatic Miniature Switches, 240 Vac 10 k a UL Listed as HCR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HCR type circuit breakers. b UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. c circuit breakers are suitable for use with 60 C or 5 C conductors circuit breakers are suitable for use with 5 C conductors. d Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. Interrupting s page -2 ccessories page -12 Dimensions Page -54 1P 120 Vac10 k IR 15 QO115HMab QO120HMab P 3P 60 QO QO QO QO Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

12 QO and QOU Miniature Circuit Breakers Table.14: Handle ttachments Handle Tie: Handle Clamp: Handle Padlock ttachment: for Padlocking in ON or OFF position Handle Padlock ttachment: for Padlocking in OFF position ccessories for Use with QO and QOB Miniature Circuit Breakers QO Circuit Breaker ccessories Class 1130 / Refer to Catalog 030CT Description Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P QO1HT 3.80 DE2E Converts any two adjacent 120/240 Vac 1P side-by-side QOT circuit breakers to independent trip 2P QOTHT 3.80 DE2E Handle tie and lock-off for three 1P QO, QOB circuit breakers QO3HT DE2E Clamp for holding QO 1P handle in ON or OFF position QO1LO 3.80 DE2E Clamp for holding QO or Q1 1P, 2P or 3P circuit breaker handles in ON or OFF position HLO DE2E For padlocking 1P QO circuit breaker in ON or OFF position Loose attachment QOHPL 9.50 DE2E Fixed attachment QO1P 10.0 DE2E For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position QOTHP DE2E For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE in either ON or OFF position, fixed attachment. GFI2P 9.20 DE2 For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position. Loose attachment QO1HPL 10.0 DE2E Fixed attachment QO1PL 10.0 DE2E For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. QO1PF DE2E For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment. QO2PF DE2E For padlocking 1P QO-GFI, QO-FI, QO-CFI, and QO-EPD circuit breakers in OFF position only, fixed attachment. QOGFI1PF DE2E For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE circuit breakers in OFF position only, fixed attachment. QOGFI2PF DE2E Ring Terminal Ring terminals are available as a factory-installed option. See Page % Price dder DE2 Sub-Feed Lugs 60 2P plug-on 2 spaces required (6 2 l/cu) QO60SL 4.10 DE P plug-on 2 spaces required (12 2/0 l/cu) QO2125SL DE P plug-on 4 spaces required (4 300 l/cu) QO2225SLa DE P plug-on 3 spaces required (12 2/0 l/cu) QO3125SL DE3 Mechanical Interlock ttachment For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-byside so that only one circuit breaker can be ON at a time (Not QOU) QO2DTI DE2E QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit With Retaining Kit: breakers in dual power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. QO2DTIM DE2E a Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 or greater. QO1HT QO1P QO1PL QO1LO QO1PF QO2DTI Table.15: ccessory Shunt Trip QO1HPL QOTHP HLO1 QOHPL QO2PF QOGFI2PF Factory-Installed ccessories for Use with QO and QOB Miniature Circuit Breakers Factory-installed electrical accessories take up an additional pole space on QO, QO-GFI, QO-EPD, QO-SWN and QOU circuit breakers. ll C electrical accessories shown below are rated for 50/60 Hz. ccessories are not available for QOB-VH (2P 150 and 3P ) circuit breakers or QO, QOU molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factoryinstalled accessories are not available for QO-FI or QO-CFI rc Fault Circuit Breakers or on QO2150, QO215, or QO2200 circuit breakers. Factory-Installed ccessories Description Trips the circuit breaker from a remote location by means of a trip coil energized from a separate circuit. 120 Vac shunt trip will operate at 55% or more of rated voltage. ll other shunt trips will operate at 5% or more of rated voltage. pplication For use with momentary or maintained push button. Not available on QO-GFI, QO-EPD, QO-FI, QOCFI. Shunt trip terminals accept (2) WG Cu. Rated Voltage Coil Burden Suffix dder C/DC V V V C V V ccessory uxiliary Switches larm Switches Description Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. pplication uxiliary switch terminals accept (2) WG Cu leads. Used with control circuits and is actuated only when the circuit breaker has tripped. Standard construction includes a normallyopen contact. pplication larm switch terminals accept (2) WG Cu leads. Contact Comb. 1 1B Max. Voltage C 120 C 120 Max. Load 5 5 Suffix dder C Schneider Electric DE2 DE2E DE3 Discount This document provided by Barr-Thorp Electric Co., Inc

13 QO and QOU Miniature Circuit Breakers QO and Multi 9 TM Mounting Bases Class 652 / Catalog 030CT9801 SN12125 QON2L40 US Mounting Base for UL489 C60 (3 conductor shown) 2009 Schneider Electric QON120L125I Table.1: Main Lug Table.18: Table.16: Voltage System QO OEM Mounting BasesUL Recognized Components Main Lug 1P Spaces Max. No. 1P Mounting Bases Main lug kit for US mounting bases, 1 lug per kit, for 6 WG to 300 kcmil cable USMBLK Terminal cover for US mounting base; provides IP20 ingress protection per IEC 60529; suitable for jumper bars or cable USMBTC e DE2 Discount QO Plug-On Mounting BasesFor unit mounting QO, QO-GFI, QO-FI and QO-EPD circuit breakers 1Ø2W 240 Vac Max. 10 k IC (Without Neutral ssembly) 1Ø3W 240 Vac Max. 10 k IC 3Ø3W 240 Vac Max. 10 k IC (Without Neutral ssy.) 3Ø4W 240 Vac Max. 10 k IC Main Wire Size WG/kcmil QON2L Cu, 12 3 l SK9948BW /0 Cu/l SK /0 Cu/l SK /0 Cu/l SK /0 Cu/l SK996BW /0 Cu/l SK /0 Cu/l QON2L Cu, 12 6 l QON24L Cu, 12 3 l QON612L /0 Cu/l QON816L /0 Cu/l QON12L /0 Cu/l QON12L100SFb /0 Cu/l QON112L125I /0 Cu/l QON11224L125I /0 Cu/l QON116L125I /0 Cu/l QON11624L125I /0 Cu/l QON120L125I /0 Cu/l QON124L125I /0 Cu/l QON132L125I /0 Cu/l QON12024L125I /0 Cu/l QON124L150I Cu/l QON124L200I Cu/l QON12L200FTLc Cu/l QON124L200I Cu/l QON124L200DLd (2) Cu/l QON130L200I Cu/l QON142L225I Cu/l QON312L /0 Cu/l QON320L /0 Cu/l QON324L /0 Cu/l QON318L Cu/l QON324L Cu/l QON330L Cu/l QON342L Cu/l QON403L60N Cu/l QON312L125I /0 Cu/l QON320L125I a /0 Cu/l QON324L125I /0 Cu/l QON318L200I Cu/l QON324L200I Cu/l QON330L200I a Cu/l QON342L225I Cu/l QO Plug-On Mounting BasesFor unit mounting QO, QO-GFI and QO-EPD circuit breakers 1Ø2W 240 Vac Max. 10 k IC (Without Neutral ssembly) QOMB1 QOMB2 QOMB3 QOB Bolt-On Mounting BasesFor unit mounting QOB, QOB-GFI, QOB-EPD circuit breakers Cu 12 2 l 14 4 Cu 12 2 l 14 4 Cu 12 2 l 3Ø3W 240 Vac Max.10 k IC (Without Neutral ssembly) QON3B Cu/l a lso IEC rated and CE marked for IEC Use only Square D brand Type QOXC, QOXD, QOHX and QOE circuit breakers for 415Y/240 Vac max. systems. b Device comes with factory-installed sub-feed lugs. c Device comes with factory-installed feed-thru lugs. d Device comes with factory-installed dual-line lugs. Solid Neutral ssemblies Number of Branch Neutral Terminals SN12125 SN20 SN12200 SN30 SN Main Neutral Lug Wire Size 4 2/0 WG 4 2/0 WG 4 WG 300 kcmil 4 WG 300 kcmil 4 WG 300 kcmil Multi-9 Mounting Bases for UL489 C60, 240 Vac max. Branch Neutral Terminal Wire Size Cu/l Cu l 14 4 WG 14 4 WG 14 4 WG 14 4 WG 14 4 WG Description Poles s Length in. mm e US US One-conductor Mounting Base US US US US US Two-conductor Mounting Base US US US US US Three-conductor Mounting Base US US US Table.19: ccessories for US Mounting Base for UL489 C WG 12 4 WG 12 4 WG 12 4 WG 12 4 WG Description e DE3 DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

14 QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers and QYU Supplementary Protectors Class 20 / Refer to Catalog 030CT Low QOU Miniature Circuit Breakers QOU unit mount miniature circuit breakers (cable-in/cable-out) are ideal for OEM applications. They have Square D s unique Visi-Trip feature and can be DIN rail-mounted or surface- or flush-mounted using mounting feet. Low QOU General Specifications Common to ll Low QOU Circuit Breakers For convenient flush mount, surface mount or DIN mount (symmetrical rail 35 x.5 DIN/EN ) Single handle with internal common trip Terminal lug wire size (1) 14 2 WG Cu or l Reversible line and load lugs Field-installable quick connectors UL Listed 48 Vdc (5 k IR) UL Listed as HCR Type10 0 High magnetic trip circuit breakers (QOU-HM) are recommended for applications where high initial inrush may occur and for individual dimmer applications. For DIN mounting rails, see IEC Starters and Relays, Section 18 High QOU Table.20: 10 k IR 22 k IR QOU Low Miniature Circuit Breakers 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac a 10 QOU110 QOU210 QOU QOU115 QOU215 QOU215H QOU QOU120 QOU220 QOU220H QOU QOU125 QOU225 QOU225H QOU QOU130 QOU230 QOU230H QOU QOU135 QOU235 QOU QOU140 QOU240 QOU QOU145 QOU245 QOU QOU150 QOU250 QOU QOU160 QOU260 QOU360 0 QOU QOU QOU QOU115VH QOU215VH QOU315VH 20 QOU120VH QOU220VH QOU320VH 25 QOU125VH QOU225VH QOU325VH QOU130VH QOU230VH QOU330VH 35 QOU135VH QOU235VH QOU140VH QOU240VH 45 QOU145VH QOU245VH 50 QOU150VH QOU250VH 60 QOU160VH QOU260VH a QOU-H interrupting rating is 10 k at 240 Vac. Table.21: QOU-HM Miniature Circuit Breakers (10 k IR) High QOU Circuit Breakers 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac 15 QOU115HM QOU120HM Table.22: QYU UL10 Recognized Supplementary Protectors (5 k IR) 1P 2 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac 10 QYU QYU QYU QYU QYU130 General Specifications Common to ll High QOU Circuit Breakers Flush mount, surface mount, and DIN rail mount. UL Listed as HCR type, Internal common trip. Non-automatic switches have the same physical packaging Non-reversible line and load lugs. as miniature circuit breakers, but provide no overcurrent or Terminal lug wire size (1) 12 2/0 WG Cu or l. short circuit protection. They are UL Listed per UL108 and UL Listed 60 Vdc per pole (5 k IR). (Note: except switches) are CS certified. Table.23: QOU High Miniature Circuit Breakers (10 k IR) 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac 80 QOU180 QOU280 QOU QOU QOU QOU QOU1100 QOU2100 QOU QOU Table.24: QOU Non-utomatic Switches 1P 120 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac 60 QOU QOU QOU QOU QOU QOU Interrupting s Page -3 ccessories Page -12, -15 Dimensions Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

15 QO and QOU Miniature Circuit Breakers QOU ccessories Class 20 / Refer to Catalog 030CT9801 4P Jumper Bar ssembly Base QOUEC Fieldinstallable Quick Connector Cover and Cover Screw QOU14100JBF QOURT Field-installable Ring Tongue Terminal Connector Crimp connectors are not included with Square D brand connectors 2P DIN Mounted QOU Circuit Breakers Mounting Foot QOUMF1 Tapped Mounting Foot Suffix 3100 Table.25: ccessories for QOU Low Circuit Breakers (Except as Noted) Description breaker on the right. a For use on low and high ampere QOU. b P and 2P, P. c DE2E Discount For QOUQ Low Circuit Breakers with Four-Point Quick-Connect Terminals QOUQ low ampere circuit breakers with four-point quick-connect terminals are provided with permanent factory-installed terminals which are affixed to the Load or OFF end of the circuit breaker. This special terminal will accommodate up to four 1/4-inch insulated female quick connect wire terminations. Total ampacity of these connections must not exceed the rating of the circuit breaker. Order Qty. Unit Factory-installed ring tongue terminal, screw, for 1P, 2P, 3P QOU, Suffix dd 20% to price Hex drive 5/32 in. wire binding screw for QOU Suffix dd 20% to price For padlocking 1P low ampere QOU circuit breaker in OFF or ON position QOU1P For padlocking 2P and 3P low ampere QOU circuit breaker in OFF or ON position QOU1PL For padlocking 1P low ampere QOU circuit breaker in OFF position only QOU1PFLc For padlocking 2P and 3P low ampere QOU circuit breaker in OFF position only QOU2PFLc For padlocking 2P and 3P high ampere QOU circuit breaker in OFF position only Suffix -100 dd 20% to price Handle lock-out, ON or OFF position HLO1c P 100 Jumper bar assy. w/front wiring with base, cover and screw 1 QOU14100JBF P 100 Jumper bar assy. w/right side wiring with base, cover and screw 1 QOU14100JBR P 100 Jumper bar assy. w/left side wiring with base, cover and screw 1 QOU14100JBL Ø, 4P, 100 Jumper bar base with front wiring 40 QOU14100BFB Ø, 4P, 100 Jumper bar base with left side wiring 40 QOU14100BLB Ø, 4P, 100 Jumper bar base with right side wiring 40 QOU14100BRB P Jumper bar cover 40 QOU14100CB Mounting screw for jumper bar cover 40 QOU1CMSB P 150 Jumper bar assy. w/front wiring with base, cover and screw 1 QOU16150JBF Ø, 6P, 150 Jumper bar base with front wiring 40 QOU16150BFB Ø, 6P, 150 Jumper bar base with left side wiring 40 QOU16150BLB Ø, 6P, 150 Jumper bar base with right side wiring 40 QOU16150BRB P jumper bar cover 40 QOU16150CB 1.10 Vertical rainproof cover 2P and 3P QO, QOU, F and K 1 BCVac BCVBac Horizontal rainproof cover 2P QO, QOU, and 3P Q2, EH 1 BCHac 10 BCHBac P Fingersafe cover for high ampere QOU circuit breaker 1 40 QOUHFSC1 QOUHFSC1B P Fingersafe cover for low ampere QOU circuit breaker 1 QOULFSC1 40 QOULFSC1B Cover plate for one 2P QOU circuit breaker 1 40 QOUCP2 QOUCP2B Cover plate for one 3P QOU circuit breaker 1 40 QOUCP3 QOUCP3B Cover plate for two 2P QOU circuit breakers 1 40 QOUCP4 QOUCP4B Cover plate for three 2P QOU circuit breakers 1 QOUCP QOUCP6B Field-installable ring tongue terminal adaptor 1 QOURT QOURTB 4.40 Quick connector end connection wiring 1 QOUEC QOUECB 4.40 Quick connector forward or reverse wiring 1 QOUFR QOUFRB P QOU mounting foot 1 QOUMF1a 80 QOUMF1Ba P QOU mounting foot 1 QOUMF2a QOUMF2Ba P QOU mounting foot 1 24 QOUMF3a QOUMF3Ba Tapped mounting foot for QOU, 1P and 2P 10 0, 3P Packaged with circuit breaker Suffix dd 20% to price Individually packaged 1 QOUMFS Bulk packed 80 QOUMFS1B 2.30 Mechanical interlock attachment: Used to interlock two circuit breakers mounted side-by-side so that only one circuit breaker can be ON at a time. 1P or 2P circuit breaker can be mounted on the left and interlocked with a 2P or 3P circuit QOU2DTILb Table.26: QOUQ Four-Point Quick-Connect Terminals Poles Order Qty. Unit dder Change QOU to QOUQ Electrical ccessories for QOU Page Schneider Electric DE2 DE2 DE2E Discount This document provided by Barr-Thorp Electric Co., Inc

16 Multi 9 Miniature Circuit Breakers 1P C60N 3P C60N 2P C60N Box Lug C60N Multi 9 C60N UL 489 Listed 240 V Miniature Circuit Breakers UL 489 Listed and CS 22.2 No.5.1 for branch circuit protection Eliminates concerns and uncertainty of using a UL 10 device where a UL 489 device is required Replaces fuses in low-ampere range; 1 ratings up to 35 Trip Curve Use Magnetic Release C For typical loads 10 x ampere rating ( 14 for DC) D For high inrush x ampere rating Table.2: UL 489 Circuit Breakers (120/240 V) () Box Lug/Box Lug C Curve 10 Times ( 14 DC) UL 489 C60N Miniature Circuit Breakers Class k IR 120 Vac; 2P and 240 Vac) 60 Vdc for 1P and 125 Vdc for 2P (on C-curve circuit breakers only, see table below) Increased installation flexibility with standard box lugs or optional ring terminals llows easy front-mounting and rear wiring when using ring terminals wide range of electrical and mechanical accessories Suitable for reverse feeding Trip-free mechanism Positive indication of contact disconnect a 1P dual rated 120 Vac/60 Vdc. b 2P dual rated 240 Vac/125 Vdc. Interrupting ratings Page -3 ccessories Page -20 Dimensions Page -54 Mounting Bases Page -13 DIN Mounting Rail Section 18 D Curve10 14 Times 1Pa 2Pb 3P 1P 2P 3P Ring Tongue/Ring Tongue Ring Tongue C60N Box/Ring C60N Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

17 Multi 9 TM Miniature Circuit Breakers Multi 9 C60 UL 489 Listed 480V Miniature Circuit Breakers UL 489 Listed, CS C22.2 No. 5.1; lso IEC ; CE marked 480Y/2 10 k (2P and 3P), 2 10 k (1P) 0.5 through 20 1P, 2P, 3P, 18 mm wide per pole UL 489 C Vac and UL489 C60N Miniature Circuit Breakers Class 860 UL 486B Listed single-barrel lug: (2) WG (1-25 mm 2 ) cables, Cu only Optional ring tongue terminals wide range of electrical and mechanical accessories Suitable for reverse feeding Trip-free mechanism Positive indication of contact disconnect 1P UL489 C60 2P UL489 C60 Trip Curve Use Magnetic Release C For typical loads 10 x ampere rating ( 14 for DC) D For high inrush x ampere rating Table.28: () UL 489 Circuit Breakers (480Y/2 Vac) C Curve 10 Times ( 14 DC) D Curve10 14 Times 1P 2P 3P 1P 2P 3P Single-Barrel Wire Lug 0.5 MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN Ring Tongue Terminal 0.5 MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN P UL489 C60 Multi 9 C60N UL 489 Listed Miniature Circuit Breakers for DC Telecommunication pplications limited range of C60N products are UL Listed as UL 489 circuit breakers for protection of DC telecommunications circuits. Table.29: UL 489 Circuit Breakers for DC Telecommunications pplications (1P, 2 Modules, C curve) () $Price () $Price Interrupting Page -3 ccessories page -20 Dimensions Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

18 Multi 9 TM Miniature Circuit Breakers New! 1P C60H-DC UL10 NC100 Circuit Breakers, UL1053 Ground Fault Protectors Multi 9 C60H-DC UL 10 Recognized Supplementary Protectors (250 and 500 Vdc) The C60H-DC supplementary protectors are used in direct current circuits (industrial control and automation, transport, renewable energy, etc.). They provide overcurrent protection within appliances or electrical equipment. Range from k IR at 250 Vdc (1-pole) and 5 k IR at 500 Vdc (2-pole, wired in series) Trip-free mechanism Positive indication of contact disconnect C-Curve to14 times ampere rating UL 10, IEC , EN , GB , CCC and CE mark. Table.30: Current ()a Class Multi 9 C60H-DC UL 10 Recognized Supplementary Protectors 1-Pole Vdc 2-Pole Vdc New! 0.5 MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN a t 25 C/ F, for other temperatures see temperature derating table in Multi 9 Catalog 0860CT0201R1/08 2P C60H-DC 2P GFP Multi 9 UL1053 Listed GFP Ground Fault Protectors Provides ground fault protection for electrical circuits. vailable in 2P (2-wire) and 4P (3- or 4-wire) versions Provides no thermal or magnetic protection. The circuit must be protected by an upstream device. Contains Si Technology to increase immunity to noise and to minimize the potential for nuisance tripping in noisy electrical environments. Table.31: Current () Maximum Sensitivity (m) Multi 9 UL 1053 Listed GFP Ground Fault Protectors Interrupting s Page -3 ccessories Page -20 Dimensions Page -54 Tripped condition due to a ground fault is displayed on the front face by a red mechanical indicator. DIN rail mounting for easy installation.. 2P UL1053 UL /240 Vac, 240 Vac, 60 Hz 2 Vac, 480Y/2 Vac, 60 Hz IEC Vac, 240 Vac, 50 Hz IEC IEC /400 Vac, 240/415 Vac, 50 Hz 230/400 Vac, 240/415 Vac, 50 Hz 4P UL Vac, 480Y/2 Vac, 60 Hz Tripping Range Family to 29.9 m GFP to 98.9 m GFP to 299 m GFP to 29.9 m GFP to 98.9 m GFP to 299 m GFP to 29.9 m GFP to 98.9 m GFP to 299 m GFP to 299 m GFP to 299 m GFP P GFP (3- or 4-wire) Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

19 1P UL 10 C60N 2P UL 10 C60N 3P UL 10 C60N 4P UL 10 C60N 2009 Schneider Electric Multi 9 TM Miniature Circuit Breakers Intended for use within equipment where branch circuit protection is already provided or not needed Range from 0.5 to k 120/240 Vac; 5 k IR at 480Y/2; 10 k 60 Vdc (1P) and 125 Vdc (2P) Suitable for reverse feeding DIN mounting for easy installation Suitable for reverse feeding Table.32: UL 10 Supplementary Protectors Interrupting s Page -3 ccessories Page -20 Dimensions Page -54 UL 10 C60N Supplementary Protectors Class 860 wide range of electrical and mechanical accessories Trip-free mechanism Positive indication of contact disconnect Trip Curve Use Magnetic Release B For sensitive equipment x ampere rating C For typical loads 10 x ampere rating ( 14 for DC) D For high inrush x ampere rating () 1P 2P 3P 4P B CurveMagnetic Setting Between 3.2 and 4.8 Times 1 MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG C CurveMagnetic Setting Between and 10 Times 0.5 MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG D CurveMagnetic Setting Between 10 and 14 Times 0.5 MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

20 Multi 9 TM Miniature Circuit Breakers C60 ccessories Class 860 Electrical ccessories for C60 Circuit Breakers and Supplementary Protectors Possible Combinations Mounted to the left of the circuit breaker with a maximum width of 54 mm Ring Tongue Terminal Kit Spacer Terminal Screw Shield SD larm Switch OF uxiliary Switch Max. 54 mm MX Shunt trip + ux Switch MN Undervoltage Release C60 C60N Padlock ttachment Rotary Handle Front Mounting Kit for C60 1P, 2P, 3P, 4P (1 per circuit breaker) MGN26380 Locking Device Left Side Mount Multi-pole Front Mounting Kit Heavy-duty Padlock ttachment New! Label Holders for 2, 3 or 4P C60N MGN26381 Locking Device Right Side Mount Comb Bus Bar Table.33: Descriptions Multi 9 C60 Electrical ccessories Control Voltage C60 Width in 9 mm UL/IEC modules Vac Vdc OF uxiliary Switch (1a1b) MG SD larm Switch (1a1b) MG MX Shunt Trip + OF uxiliary Switch (1a1b) MN Undervoltage Release Multi-9 GFP UL 1053 Listed Ground Fault Protectors 120 to 480Y/2 Vac; 30, 100, and 300 m; 2P and 4Ps. See page -18 Handout, 0860HO0602 or Catalog 0860CT0201 Table.34: Multi 9 C60 Mechanical ccessories Descriptions a Left-side mounted padlocking device cannot be used in conjunction with accessories SD, OF, MX or MN. Use rightside mounted padlocking device when accessories are required. b Right-side mounted padlocking device cannot be used in conjunction with VIGI module. Use left-side mounted padlocking device when VIGI Module is required.. C60 Ring tongue terminal kit for UL10 C60N For one pole Spacer for DIN rail, Not UL Recognized 9 mm wide MG Padlock ttachment (1 per for 1P, 2P, 3P or 4P) 2 per pack MG Heavy-duty Padlock ttachment for C60N, Locks OFF only 2 per pack M9PF Padlocking Device Left Side Mount, Locks OFF onlya MGN per pack Padlocking Device Right Side Mount, Locks OFF onlyb MGN P MG Front Mounting Kit 2P MG P MG P MG Label holders for 2, 3 or 4P C60 (Not UL Recognized) Bag of 10 MG Terminal Screw Shield (Not UL Recognized) Bag of two 4P shields MG P MG Terminal cover (Not UL Recognized) 2P MG P MG2695+MG2696 4P MG Ø MG Comb Bus Bar Kit for UL10 C60, 12 poles, Fixed Length 2Ø MG Ø MG Tooth Caps for UL Comb Bus Bar, Bag of Rotary Handle for C60 (Non UL Recognized) Operating Subassembly MG Door Interlock Handle 2P/3P/4P MG Fixed Handle (Front or Lateral) MG Multi-pole Front Mounting Kit Rail Support (20 of 9 mm modules) Hinged Transparent Cover Multi 9 SPD (Surge Protective Device) see Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

21 PowerPact Molded Case Circuit Breakers PowerPact Family Class 611 The PowerPact dvantage Proven Performance: Industry-leading circuit breaker innovation and protection for heavy-duty commercial and industrial applications. Flexible: Full range of molded case circuit breakers from 15 to 3000, delivering the ratings, configurations, and operators for your unique applications. Simple: Common catalog numbers, standardized ratings, and a full range of field-installable accessories make product selection, installation and maintenance easier than ever. Common Design Features: Mounting holes, door trim, and handle accessories G-Frame 100 H-Frame 150 J-Frame 250 Q-Frame 250 D-Frame 600 M-Frame 800 P-Frame 1200 R-Frame 3000 Table.35: Voltage PowerPact Interrupting s a P-frame K interrupting is 50 k at 480 and 600 Vac. Interrupting B D G J K L 240 Vac 10 k 25 k 65 k 100 k 65 k 125 k 480 Vac 18 k 35 k 65 k 65 k a 100 k 600 Vac 14 k 18 k 25 k 65 k a 50 k Table.36: Common Catalog Numbering System Frame Termination Poles Voltage mperage b Suffix Code Suffix Code H G L B S 110 Vac Shunt Trip 2/2B uxiliary Switch Frame Designation Interrupting Terminations G 100 Frame I-Line H 150 Frame Vac Vac Vac L Lugs on Both Ends J 250 Frame B 10 k F Bus Bar (No Lugs) Q 250 Frame D 25 k 18 k 14 k M Lugs Line Side Only D 600 Frame G 65 k 35 k 18 k P Lugs Load End Only M 800 Frame J 100 k 65 k 25 k N Plug-in P 1200 Frame K 65 k 65 k 65 k D Drawout R 3000 Frame L 125 k 100 k 50 k S Rear Connected Studs b For amperage of M-, P- or R-frame circuit breakers, add a zero to the three amperage digits; for example, 120 = Description Page H- and J-Frame Circuit Breakers H- and J-Frame Circuit Breakers G- and Q-Frame Circuit Breakers D- and M-Frame Circuit Breakers P-Frame Circuit Breakers R-Frame Circuit Breakers PowerPact H- and J-Frame Electronic Motor Circuit Protectors Mag-Gard Motor Circuit Protectors (MCP) utomatic Switches Vdc Circuit Breakers Mission Critical Circuit Breakers PowerPact Circuit Breaker ccessories Motor Operators and Rotary Handles Locks, Installation ccessories, and Rear Connections Mechanical Lugs Compression Lugs and Power Distribution Connectors (PDC) Terminal Nuts, Terminal Pads, Terminal Shields and ccessories Plug-In and Drawout Mountings Micrologic Electronic Trip Units Micrologic Trip Unit ccessories Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

22 PowerPact Circuit Breakers H- and J-Frame Circuit Breakers Class 611 / Refer to Catalog 0611CT HD and HG 2P 2P HJ, HL in 3P module H-Frame J-Frame Table.3: 40 o C Fixed C Magnetic Trip H-Frame 150 and J-Frame 250 Thermal-Magnetic UL Current-Limitinge Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unit Suitable for Reverse Connectiona bc Interrupting (2nd Letter of Catalog Number) D G Je Le Hold Trip 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated H-Frame, 150 2P, 600 Vac 50/60 Hz, 250 Vdc H( )L26015(C) H( )L26020(C) H( )L26025(C) H( )L26030(C) H( )L26035(C) H( )L26040(C) H( )L26045(C) H( )L26050(C) H( )L26060(C) H( )L2600(C) H( )L26080(C) H( )L26090(C) H( )L26100(C) H( )L26110(C) H( )L26125(C) H( )L26150(C) H-Frame 150 3P, 600 Vac 50/60 Hz, 250 Vdc H( )L36015(C) H( )L36020(C) H( )L36025(C) H( )L36030(C) H( )L36035(C) H( )L36040(C) H( )L36045(C) H( )L36050(C) H( )L36060(C) H( )L3600(C) H( )L36080(C) H( )L36090(C) H( )L36100(C) H( )L36110(C) H( )L36125(C) H( )L36150(C) o C djustable C Magnetic Trip bc Interrupting (2nd Letter of Catalog Number) D G Je Le Low High 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated J-Frame 250 2P, 600 Vac 50/60 Hz, 250 Vdc Terminal Wire Range L150HD 14 3/0 WG l or Cu L150HD 14 3/0 WG l or Cu Terminal Wire Range J( )L26150(C) L15JD J( )L2615(C) /0 WG l or Cu J( )L26200(C) L250JD J( )L26225(C) J( )L26250(C) J-Frame 250 3P, 600 Vac 50/60 Hz, 250 Vdc 3/0 WG 350 kcmil l or Cu J( )L36150(C) L15JD J( )L3615(C) /0 WG l or Cu J( )L36200(C) L250JD J( )L36225(C) J( )L36250(C) a See page -23 for circuit breakers with field interchangeable trip units. b To complete catalog number, replace the blank with the appropriate rating (D, G, J, L). c For 100% rated circuit breakers add a C in the 9th character place (for example, HDL26015C or JDL26150C). d 100% rated J frame breakers have copper lugs and can only be used with copper wire. e J and L interrupts are UL certified as current limiting. 3/0 WG 350 kcmil l or Cu Table.38: H- and J-Frame Termination Options Termination Letter - I-Line (See Section 9) For factory-installed termination, place termination F = No Lugs (includes terminal nut kit on both ends)f letter in the third block of the L = Lugs both ends circuit breaker catalog number. M = Lugs ON end Terminal Nut Kit OFF end P = Lugs OFF end Terminal Nut Kit ON end N = Plug-in g H G L Termination Letter D = Drawout g S = Rear Connected g f dd TS suffix for circuit breaker without terminal nut kit. Plug-in Drawout Rear Connected g For N and D pricing, add termination pricing on page -42 to price. For S pricing, add termination pricing on page -38 to price. Table.39: Voltage H- and J-Frame Interrupting s Interrupting D G J L 240 Vac 25 k 65 k 100 k 125 k 480 Vac 18 k 35 k 65 k 100 k 600 Vac 14 k 18 k 25 k 50 k ccessories Page -36 Optional Lugs Page -39 Dimensions Page -55 Enclosures Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

23 H-Frame Trip Unit PowerPact Circuit Breakers Table.40: H- and J-Frame Circuit Breakers Class 611 / Refer to Catalog 0611CT0401 H-Frame 150 UL Current-Limitingc Circuit Breaker Frame with Field-Interchangeable Thermal-Magnetic Trip Unitsa (600 Vac, 250 Vdc) Fixed C D Interrupting G Interrupting Jc Interrupting Lc Interrupting Magnetic Trip Terminal Wire Range Hold Trip 3P, 600 Vac 50/60 Hz HDL36015T HGL36015T HJL36015T HLL36015T HDL36020T HGL36020T HJL36020T HLL36020T HDL36025T HGL36025T HJL36025T HLL36025T HDL36030T HGL36030T HJL36030T HLL36030T HDL36035T HGL36035T HJL36035T HLL36035T HDL36040T HGL36040T HJL36040T HLL36040T HDL36045T HGL36045T HJL36045T HLL36045T HDL36050T HGL36050T HJL36050T HLL36050T HDL36060T HGL36060T HJL36060T HLL36060T HDL3600T HGL3600T HJL3600T HLL3600T HDL36080T HGL36080T HJL36080T HLL36080T HDL36090T HGL36090T HJL36090T HLL36090T HDL36100T HGL36100T HJL36100T HLL36100T HDL36110T HGL36110T HJL36110T HLL36110T HDL36125T HGL36125T HJL36125T HLL36125T HDL36150T HGL36150T HJL36150T HLL36150T Table.41: J-Frame 250 UL Current-Limitingc Circuit Breaker Frame with Field-Interchangeable Thermal-Magnetic Trip Unitsa (600 Vac, 250 Vdc) L150HD 14 3/0 WG l or Cu djustable C Magnetic Trip D Interrupting G Interrupting Jc Interrupting Lc Interrupting Terminal Wire Range Low High 3P, 600 Vac 50/60 Hz JDL36150T JGL36150T JJL36150T JLL36150T L15JD JDL3615T JGL3615T JJL3615T JLL3615T /0 WG l or Cu JDL36200T JGL36200T JJL36200T JLL36200T L250JD JDL36225T JGL36225T JJL36225T JLL36225T /0 WG 350 kcmil l JDL36250T JGL36250T JJL36250T JLL36250T or Cu a Circuit breakers will be labeled with Line and Load markings and are not suitable for reverse connections. Only available on standard (80%) rated 3P unit-mount circuit breakers; not available with I-Line or Plug-In constructions. Table.42: Circuit Breaker Frame H-Frame 150 and J-Frame 250 3P Basic UL Current-Limitingc Circuit Breaker Frame Without Terminationsb or Trip Unit (600 Vac, 250 Vdc) D Interrupting G Interrupting Jc Interrupting Lc Interrupting HDF36000F HGF36000F HJF36000F HLF36000F H-Frame HDF36000F HGF36000F HJF36000F HLF36000F J-Frame JDF36000F JGF36000F JJF36000F JLF36000F b See page -39 for lug and termination kits. c J and L interrupts are UL Certified as current limiting. Table.43: H-Frame and J-Frame 3P Field-Installable Thermal-Magnetic Trip Unit H-Frame H-Frame J-Frame mperage mperage mperage 15 HT HT JT HT HT JT HT HT JT HT HT JT HT HT JT HT HT HT HT HT HT Table.44: Voltage H- and J-Frame Interrupting s Interrupting D G J L 240 Vac 25 K 65 k 100 k 125 k 480 Vac 18 k 35 k 65 k 100 k 600 Vac 14 k 18 k 25 k 50 k Table.45: H- and J-Frame Termination Options 2009 Schneider Electric Termination Letter For factory-installed - I-Line (See Section 9) termination, place termination F = No Lugs (includes terminal nut kit on both ends)d letter in the third block of the L = Lugs both ends circuit breaker catalog number. M = Lugs ON end Terminal Nut Kit OFF end P = Lugs OFF end Terminal Nut Kit ON end H D L T N = Plug-in e Termination Letter D = Drawout e S = Rear Connected e d dd TS suffix for circuit breaker without terminal nut kit. e For N and D pricing, add termination pricing on page -42 to price. For S pricing, add termination pricing on page -38 to price. ccessories page -36 Optional Lugs Page -39 Dimensions Page -55 Enclosures Page -56 DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

24 PowerPact Circuit Breaker GJL 3P Circuit Breaker QBL 2P QBL 3P Table.46: G- and Q-Frame Circuit Breakers Class 034, 0500 / Refer to Catalogs: 034CT0201, 0500CT902 PowerPact G-Frame 3P 100 Thermal-Magnetic Circuit Breaker (600Y/34 Vac) djustable C Magnetic Trip J Interrupting Low High GJL GJL GJL GJL GJL GJL GJL GJL GJL GJL Table.4: Table.48: 2P, 240 Vac G-Frame Interrupting s Voltage J interrupting 240 Vac 100 k 480 Vac 65 k 600Y/34 Vac 18 k Terminal Wire Range 14 1/0 WG Cu or 8 1/0 WG l PowerPact Q-Framea250 Thermal-Magnetic Circuit Breaker (240 Vac) 240 Vace 10 k 25 k 65 k 100 kf e Q-frame circuit breakers are 240 Vac only. f 3P QJ circuit breakers are rated at 208Y/120 Vac only. Fixed C Magnetic Trip B Interrupting D Interrupting G Interrupting J Interrupting Terminal Wire Range Hold Trip c c c c QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL #4 WG kcmil QBL QDL QGL QJL l/cu QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL22250b QDL22250b QGL22250b QJL22250b P, 240 Vac QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL #4 WG kcmil l/cu QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL32250b QDL32250b QGL32250b QJL32250b a Replacement lugs and electrical accessories are not available for PowerPact Q-frame circuit breakers. b 250 lugs are suitable for copper conductors only c DE2 Discount Table.49: Q-Frame Termination Options Termination Letter For factory-installed termination, place = I-Line (See Section 9) termination letter in the third block of the E = Bolt-on I-Line (See Section 9) circuit breaker catalog number. F = No Lugs (includes terminal nut kit on both ends)d L = Lugs both ends Q G L M = Lugs ON end, Studs on OFF end Termination Letter P = Lugs OFF end, Studs on ON end d dd TS suffix for circuit breakers without terminal nut kit. See Catalog 034CT0201 for additional information. Table.50: Voltage Q-Frame Interrupting s Interrupting B D G J ccessories Page -36 Optional Lugs Page -39 Dimensions Page -55 Enclosures Page Schneider Electric DE2 DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

25 PowerPact Circuit Breakers D- and M-Frame Circuit Breakers Class 612, 615 / Refer to Catalogs: 0612CT0101, 0616CT0801 Table.51: Electronic Trip Unit Type Standard mmeter Table.52: D-Frame ( Vac) 3P 50/60 Hz Circuit Breaker with Lugs and Electronic Trip Unitsc Trip Function LS LSI LSIG LSI LSIG Trip Unit Continuous Currenta G Interrupting J Interrupting L Interrupting Terminal Wire Range (WG/kcmil) 150 DGL36150E DJL36150E DLL36150E STR23SP 250 DGL36250E DJL36250E DLL36250E (1) Cu or (1) l 400 DGL36400E DJL36400E DLL36400E DGL36600E DJL36600E DLL36600E (2) 2/0 350 Cu or (2) 2/0 500 l 150 DGL36150E DJL36150E DLL36150E SR53UP-Fb 250 DGL36250E DJL36250E DLL36250E (1) Cu or (1) l 400 DGL36400E DJL36400E DLL36400E DGL36600E DJL36600E DLL36600E (2) 2/0 350 Cu or (2) 2/0 500 l 150 DGL36150E DJL36150E DLL36150E STR53UP-FTb 250 DGL36250E DJL36250E DLL36250E (1) Cu or (1) l 400 DGL36400E DJL36400E DLL36400E DGL36600E DJL36600E DLL36600E (2) 2/0 350 Cu or (2) 2/0 500 l 150 DGL36150E DJL36150E DLL36150E STR53UP-FIb 250 DGL36250E DJL36250E DLL36250E (1) Cu or (1) l 400 DGL36400E DJL36400E DLL36400E DGL36600E DJL36600E DLL36600E (2) 2/0 350 Cu or (2) 2/0 500 l 150 DGL36150E DJL36150E DLL36150E DGL36250E DJL36250E DLL36250E (1) Cu or (1) l STR53UP-FTIb 400 DGL36400E DJL36400E DLL36400E DGL36600E DJL36600E DLL36600E (2) 2/0 350 Cu or (2) 2/0 500 l a D-frame circuit breakers 400 and below are 100% rated. 600 is standard (80%) rated only. b F = Fault indicator; T = Residual-type ground-fault protection; I = mmeter c vailable with lugs (L) or bus (F) connections only. D-Frame 3P 600 Circuit Breaker, Frame Only, and Field-Installable Trip Units Basic Frame Only (600 Vac)d Field Installable D-Frame Electronic Trip Unit G Interrupting J Interrupting L Interrupting Long-time, Short-time and Instantaneous Protection Description Factory Code Trip Function 150 DGL36150F DJL36150F DLL36150F STR23SP E20 LS DGL36250F DJL36250F DLL36250F STR53UP-F E53 LSI DGL36400F DJL36400F DLL36400F STR53UP-FT E54 LSIG DGL36600F DJL36600F DLL36600F STR53UP-FI E58 LSI d vailable with lugs (L) or bus (F) connections only. STR53UP-FTI E59 LSIG Table.53: M-Frame 800, Basic Electronic Trip System Type ET 1.0e Factory-Sealed Trip Unit D-Frame Circuit Breaker M-Frame Circuit Breaker Electronic Trip Unit Type 2P, 600 Vac 50/60 Hz Basic 3P, 600 Vac 50/60 Hz Trip Function Fixed Long-time, djustable Instantaneous Trip Sensor f For N, D, and S pricing, add termination pricing to price. See page -42. G Interrupting J Interrupting Terminal Wire Range (WG/kcmil) 300 MGL MJL MGL MJL MGL MJL MGL MJL MGL MJL MGL MJL MGL MJL MGL MJL (3) 3/0 500 l/cu 300 MGL MJL MGL MJL Fixed 400 MGL MJL Basic Long-time, 450 MGL MJL djustable (3) 3/0 500 l/cu Instantaneous 500 MGL MJL Trip 600 MGL MJL MGL MJL MGL MJL e The ET 1.0 trip unit cannot be field replaced or have the long-time trip point setting adjusted. It is considered an electronic equivalent of a thermal-magnetic circuit breaker. Table.54: Frame D-Frame M-Frame Termination Letter F L M P N f D f S f F L M P Termination Options Termination Option No Lugs (Includes terminal nut kit on both ends) Lugs both ends Lugs ON end Terminal Nut Kit Off end Lugs OFF end Terminal Nut Kit On end Plug-in Drawout Rear Connected No Lugs Lugs both ends Lugs ON end Terminal Nut Kit Off end Lugs OFF end Terminal Nut Kit On end For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number. M G L or D G L E 2 0 Termination Letter Table.55: Voltage D- and M-Frame Interrupting s Interrupting G J Lg 240 Vac 65 k 100 k 125 k 480 Vac 35 k 65 k 100 k 600 Vac 18 k 25 k 25 k g L interrupting rating is not available in M-frame. ccessories page -36 Optional Lugs page -39 Dimensions page -55 Enclosures page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

26 PowerPact Circuit Breakers Table.56: P-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT0101 P-Frame 1200 (600 Vac, 50/60 Hz) 3Pa Circuit Breaker with Electronic Trip Unit Electronic Trip Unit Type Function Code Basic Electronic Fixed long-time, Trip Unit djustable (Not Instantaneous ET1.0I Interchangeable) Micrologic Interchangeable Standard Trip Unit Micrologic Interchangeable mmeter Trip Unit Micrologic Interchangeable Power Trip Unit Micrologic Interchangeable Harmonic Trip Unit LI 3.0 LSI 5.0 LI 3.0 LSI 5.0 LSIG 6.0 LSI 5.0P LSIG 6.0P LSI 5.0H LSIG 6.0H Sensor bc G Interruptingb J Interruptingb K Interruptingb L Interruptingbd 80% Rated 100% Ratedc 80% Rated 100% Ratedc 80% Rated 100% Rated c 80% Rated 100% Ratedc Terminal Wire Range 600 P( )L (3) 3/0 WG 500 kcmil 800 P( )L36080 l or Cu 1000 P( )L (4) 3/0 WG 500 kcmil 1200 P( )L36120 l or Cu 250 P( )L36025(C)U P( )L36040(C)U31 (3) 3/0 WG 500 kcmil P( )L36060(C)U31 l or Cu 800 P( )L36080(C)U P( )L36100(C)U (4) 3/0 WG 500 kcmil 1200 P( )L36120(C)U31 l or Cu 250 P( )L36025(C)U P( )L36040(C)U P( )L36060(C)U P( )L36080(C)U (3) 3/0 WG 500 kcmil l or Cu 1000 P( )L36100(C)U33 (4) 3/0 WG 500 kcmil P( )L36120(C)U33 l or Cu 250 P( )L36025(C)U P( )L36040(C)U P( )L36060(C)U P( )L36080(C)U41 (3) 3/0 WG 500 kcmil l/cu 1000 P( )L36100(C)U (4) 3/0 WG 500 kcmil 1200 P( )L36120(C)U41 l or Cu 250 P( )L36025(C)U P( )L36040(C)U P( )L36060(C)U P( )L36080(C)U (3) 3/0 WG 500 kcmil l or Cu 1000 P( )L36100(C)U43 (4) 3/0 WG 500 kcmil P( )L36120(C)U43 l or Cu 250 P( )L36025(C)U P( )L36040(C)U P( )L36060(C)U P( )L36080(C)U44 (3) 3/0 WG 500 kcmil or Cu 1000 P( )L36100(C)U (4) 3/0 WG 500 kcmil 1200 P( )L36120(C)U44 l or Cu 250 P( )L36025(C)U63E1 400 P( )L36040(C)U63E1 600 P( )L36060(C)U63E1 800 P( )L36080(C)U63E (3) 3/0 WG 500 kcmil or Cu 1000 P( )L36100(C)U63E1 (4) 3/0 WG 500 kcmil P( )L36120(C)U63E1 or Cu 250 P( )L36025(C)U64E1 400 P( )L36040(C)U64E1 600 P( )L36060(C)U64E1 800 P( )L36080(C)U64E1 (3) 3/0 WG 500 kcmil or Cu 1000 P( )L36100(C)U64E (4) 3/0 WG 500 kcmil 1200 P( )L36120(C)U64E1 l or Cu 250 P( )L36025(C)U3E1 400 P( )L36040(C)U3E1 600 P( )L36060(C)U3E1 800 P( )L36080(C)U3E (3) 3/0 WG 500 kcmil l or Cu 1000 P( )L36100(C)U3E1 (4) 3/0 WG 500 kcmil P( )L36120(C)U3E1 l or Cu 250 P( )L36025(C)U4E1 400 P( )L36040(C)U4E1 600 P( )L36060(C)U4E1 800 P( )L36080(C)U4E1 (3) 3/0 WG 500 kcmil l or Cu 1000 P( )L36100(C)U4E (4) 3/0 WG 500 kcmil or Cu 1200 P( )L36120(C)U4E1 a For 2P and 4P information see Catalog 0612CT0101. b To complete the catalog number, replace the ( ) with the appropriate interrupting rating (G, J, K or L). c For 100% rated circuit breakers add a C in the 9 th character place. For example, the catalog number for a 100% trip unit with LI trip functions at 250 would be PGL36025CU31. d For all L interrupting rating, change the 5 th character (voltage rating) from a 6 (600V) to a 4 (480V); for example, PLL34025U31. The 480V IR is standard 100 k, but the 600V IR is only 25 k. Table.5: P-Frame Termination Options Table.58: P-Frame and R-Frame Interrupting s For factory-installed termination, place F = No Lugs (Includes terminal nut kit on both ends) termination letter in the third block of P-Frame Interrupting R-Frame Interrupting Voltage L = Lugs both ends the circuit breaker catalog number. G J K L G J K L M = Lugs ON end, terminal nut kit OFF end 240 Vac 65 k 100 k 65 k 125 k 65 k 100 k 65 k 125 k P G L U 4 1 P = Lugs OFF end, terminal nut kit ON end 480 Vac 35 k 65 k 50 k 100 k 35 k 65 k 65 k 100 k D = Drawout Termination Letter 600 Vac 18 k 25 k 50 k 25 k 18 k 25 k 65 k 50 k = I-Line (See Section 9) R-frame catalog numbers and pricing Page -2 Dimensions Page -55 Trip Unit Options Page -43 Optional Lugs Page -39 lternate Plugs Page -44 Enclosure Page -56 ccessories Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

27 Table.59: PowerPact Circuit Breakers R-Frame 3000 (600 Vac, 50/60 Hz) 3Pa Circuit Breaker with Electronic Trip Unit R-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT0101 Electronic Trip Unit Sensor bc G Interruptingbd J Interruptingbd K Interruptingbd L Interruptingbd Type Function Code 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated Basic Electronic Trip Unit (Not Interchangeable) Micrologic Interchangeable Standard Trip Unit Micrologic Interchangeable mmeter Trip Unit Micrologic Interchangeable Power Trip Unit Micrologic Interchangeable Harmonic Trip Unit Note: Fixed 1200 R( )F36120 long-time, 1600 R( )F ET1.0I djustable 2000 R( )F36200 Instantaneous 2500 R( )F R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U31 LI R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U33 LSI R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U41 LI R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U43 LSI R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U44 LSIG R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U R( )F36060(C)U63E1 800 R( )F36080(C)U63E R( )F36100(C)U63E R( )F36120(C)U63E1 LSI 5.0P 1600 R( )F36160(C)U63E R( )F36200(C)U63E R( )F36250(C)U63E R( )F36300(C)U63E R( )F36060(C)U64E1 800 R( )F36080(C)U64E R( )F36100(C)U64E R( )F36120(C)U64E1 LSIG 6.0P 1600 R( )F36160(C)U64E R( )F36200(C)U64E R( )F36250(C)U64E R( )F36300(C)U64E R( )F36060(C)U3E1 800 R( )F36080(C)U3E R( )F36100(C)U3E R( )F36120(C)U3E1 LSI 5.0H 1600 R( )F36160(C)U3E R( )F36200(C)U3E R( )F36250(C)U3E R( )F36300(C)U3E R( )F36060(C)U4E1 800 R( )F36080(C)U4E R( )F36100(C)U4E R( )F36120(C)U4E1 LSIG 6.0H 1600 R( )F36160(C)U4E R( )F36200(C)U4E R( )F36250(C)U4E R( )F36300(C)U4E R-frame circuit breakers can be bus- or cable-connected. For cable connections, optional terminal pad kit RLTB or equivalent bus structure is required. Each RLTB kit contains terminal pads for one end of the circuit breaker only and has provisions for mounting a maximum of 8 lugs per phase (9 lugs for 3000 ). RLTB kits are included with % rated circuit breakers. The RL3TB kits are included with the 3000, 80% and 100% rated circuit breakers. For other circuit breakers, order terminal pad kit (RLTB) and optional lugs separately. See pages a For 2P and 4P information see Catalog 0612CT0101. b To complete the catalog number, replace the blank ( ) with the appropriate interrupting rating (G, J, K or L). c Listed catalog numbers are for 80% rated circuit breakers. For 100% rated circuit breakers add a C in the 9 th character place. For example, the catalog number for a 100% standard trip unit with LI trip functions at 2500 would be RGF36250CU31. d See page -26 for interrupting ratings table Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

28 Motor Circuit Protectors PowerPact H- and J-Frame Electronic Motor Circuit Protectors Class 611 / Refer to Catalog 0611CT PowerPact H- and J-frame electronic Motor Circuit Protectors (MCP) are magnetic-only instantaneous-trip circuit breakers. They are designed to offer short circuit protection and are National Electrical Code (NEC) compliant when installed as part of a combination controller having motor overload protection. MCP circuit breakers accept the same accessories and terminals as the equivalent thermal-magnetic circuit breakers. Determine the hp rating from the nameplate of the motor. Select a MCP with an ampere rating recommended for the hp and voltage involved. When using the automatic settings the MCP microprocessor automatically adjusts the trip settings for both current and time to align with the start-up characteristic for the motor type, whether it is a standard or energyefficient motor. This includes a dampening means to accommodate a transient motor inrush current without nuisance tripping of the circuit breaker. Standard Energy Efficient Energie Efficace Energia Eficiente Table.60: Frame Current H- and J-Frame Electronic Motor Circuit Protectors (MCP) Full Load s Range djustable Instantaneous Trip Range Suffix J Interrupting (See SCCR Table Below) L Interrupting (See SCCR Table Below) M1 HJL36030M HLL36030M H-Frame M2 HJL36050M HLL36050M M3 HJL36100M HLL36100M M4 HJL36150M HLL36150M J-Frame M5 JJL36250M JLL36250M Motor Type / Tipo de Motor / Type de Moteur Standard t Energy Efficient Energie Efficace Energia Eficiente Standard Energy Efficient Energie Efficace Energia Eficiente I Table.61: Maximum or Setting of Motor Protective Devicesa Type of Motor Setting Percentage of Full-load Current Not to Exceedb, B, C, D Standard 800% 1300% B, E Energy Efficient 1100% 100% a Based on 2005 NEC Table b See NEC Exception No. 1 to Table The NEC 1300% maximum setting may be inadequate for instantaneous trip circuit breakers to withstand current surges typical of the magnetization current of autotransformer type reduced voltage starters, or open transition wye-delta starters during transfer from start to run, constant hp multi-speed motors, and motors labeled high efficiency. Table.62: MCP Selection by HP sc of Induction-type Squirrel-Cage and Wound-rotor Motorsd 3Ø 60 Hz Voltagese 200 Vac 230 Vac 460 Vac 55 Vac Full-Load s M M M M M5 c Based on 2005 NEC Table d Per NEC 430.3, part-winding motors should select two circuit breakers, each at not more than one-half the allowable trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a disconnecting means per NEC e Listed voltages are rated motor voltages. Corresponding system voltages are 200 Vac, Vac, Vac and Vac. Select wire and circuit breakers based on horsepower rather than nameplate full-load current per NEC () for general motor applications. Short Circuit Current (SCCR) Tested to meet NEC and UL508 requirements for short circuit current ratings as part of an approved combination controller. Table.63: Contactor/Starter Short Circuit Current s (SCCR) J Interrupting L Interrupting Suffix Vac 480 Vac 600 Vac Vac 480 Vac 600 Vac Tesys D-line and F-line 100 k 65 k 25 k 125 k 100 k 50 k NEM Type S 100 k 65 k 25 k 125 k 100 k 50 k See for specific ratings and combination ID numbers. ccessories Page -36 Optional Lugs Page -39 Dimensions Page -55 Enclosures Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

29 Motor Circuit Protectors H-Frame and J-Frame MCP Selector Class 611 / Refer to Catalog 0611CT0401 Table.64: pplication of PowerPact H-Frame and J-Frame Electronic Motor Circuit Protectors (MCP) Horsepower of Induction-type Squirrel-cage and Wound-rotor Motors 3Ø 60 Hz NEC Full Load Starter Size 200 Vac 230 Vac 480 Vac 55 Vac s 1/ / / / / / / / / / / / / / / / Shaded area is not covered by J-frame electronic motor circuit protector. PowerPact H-Frame and J-Frame Electronic MCP HJL36030M1 and HLL36030M1 1/2 10 hp HJL36100M3 and HLL36100M hp JJL36250M5 and JLL36250M hp HJL36050M2 and HLL36050M hp HJL36150M4 and HLL36150M hp 2009 Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

30 Motor Circuit Protectors Mag-Gard Motor Circuit Protectors (MCP) Class 580, 585, 680, Mag-Gard Motor Circuit Protectors (MCP) are instantaneous-trip magnetic-only circuit breakers. They have a single adjustment which simultaneously sets the magnetic trip level of each individual pole. Mag-Gard circuit breakers comply with NEC requirements for providing motor circuit protection when installed as part of a UL Listed combination controller having motor overload protection. Interrupting ratings are established for these UL Recognized Components only when they are used in combination with motor starters with properly sized overload relays and contactors. ll Mag-Gard circuit breakers will accept the same lugs and accessories as equivalent circuit breakers. Mag-Gard circuit breakers are available with I-Line construction.c High-interruption (H) construction Mag-Gard circuit breakers (LHL and MHL) are also available. Table.65: GJLc LL 400 MLd PJL PLL Magnetic Only Vac, 50/60 Hza djustableb Trip Range () Suffix 25M 26M 30M 33M 36M 40M 42M 44M 45M 46M 4M 3P only GJL36003M01 GJL3600M02 GJL36015M03 GJL36030M04 GJL36050M05 GJL3605M06 LL M LL M LL M LL M LL M LL M LL M LL M ML36600 ML36800 ML J-Interrupting600 Vac dd Suffix PJL36060M PJL36080M PJL36100M PJL36120M L-Interrupting480 Vac PLL34060M PLL34080M PLL34100M PLL34120M a 250 Vdc ratings are available except on PJ and PL. No UL component recognition. Circuit Breaker LL ML 250 Vdc Multiplier High = 1.2 Low = 1.4 High = 1.1 Low = 1.2 b UL magnetic trip tolerances are -20%/+30% from the nominal values shown. c No GJL I-Line available. d Each ampere rating can be ordered with any designated trip range for the frame by adding the proper suffix to the catalog numbers. ccessories page -36 and Supplemental Digest Optional Lugs Page -39 and Supplemental Digest Dimensions Pages -54 and -55 Enclosures Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

31 Motor Circuit Protectors djustable instantaneous-trip circuit breakers are intended for use in combination with motor starters with overload relays for the protection of motor circuits from short circuits. Other specific applications include rectifiers and resistance welders. These circuit breakers contain a magnetic trip element in each pole with the trip point adjustable from the front. Interrupting ratings are determined by testing the instantaneous-trip circuit breakers in combination with a contactor and overload relay. Select instantaneous-trip circuit breakers as follows: This selection table is suitable for motors, other than NEM Design E, with locked-rotor indicating code letters per NEC Table 430. (b) as follows: Table.66: Horsepower 1/2 or less 3/4 to 1-1/2 2 to 3 5 to to or more Locked-Rotor Indicating Codes Motor Code letter L K J H G F 1. For other motors order a special thermal-magnetic circuit breaker with magnetic trip settings for the specific motor GJ-, L-, and M-Frame MCP Selection Class 680 specify motor horsepower, voltage, frequency, full-load current and code letter or locked rotor current. 2. Determine motor hp rating from the motor nameplate. 3. Refer to the tables and select an instantaneous-trip circuit breaker with an ampere rating recommended for the hp and voltage involved. 4. Select an adjustable trip setting of at least 800%, not to exceed 1300%, of the motor full-load amperes (FL) for other than Design E motors. For Design E motors, select an adjustable trip setting of at least 1100% not to exceed 100% of FL. 5. The NEC 1300% maximum setting may be inadequate for instantaneous-trip circuit breakers to withstand current surges typical of the magnetization current of autotransformer type reduced voltage starters, or open transition wye-delta starters during transfer from start to run, constant hp multi-speed motors, and motors labeled high efficiency. Select thermalmagnetic circuit breakers from page -32 for those applications. 6. Part-winding motors, per NEC 430.3, should have two circuit breakers selected from the above at not more than one half the allowable trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a disconnecting means per NEC Based on NEC and NEC Table See page -30 for a available djustable Instantaneous-Trip Circuit Breakers. Table.6: Hp s of Induction Type Squirrel-Cage and Wound Rotor Motors 200 Vac 230 Vac 3Ø 60 Hz 460 Vac GJL djustable Instantaneous-Trip Circuit Breakers for Single Motor Circuit Protection 55 Vac Full Load sa GJL Family Mag-Gard Circuit Breaker Magnetic Trip Settingsb MIN MX 1/2 0.8 GJL36003M01c 1100% 4100% 1/2 1 GJL36003M01c 900% 3300% 3/4 1.1 GJL36003M01c 800% 3000% 3/4 1.4 GJL36003M01 600% 2400% GJL36003M01 500% 1800% 1/2 2 GJL36003M01 500% 100% 1-1/2 2.1 GJL36003M01 400% 1600% 1/2 2.3 GJL36003M01 400% 1400% 1-1/2 2.6 GJL36003M01 300% 1300% 2 2. GJL36003M01d 300% 1200% 3/4 2.8 GJL36003M01d 300% 1200% 3/4 3.2 GJL3600M02 00% 2400% GJL3600M02 600% 2300% GJL3600M02 600% 2100% GJL3600M02 500% 2000% GJL3600M02 500% 1900% GJL3600M02 400% 1600% 1-1/2 5.2 GJL3600M02 400% 1500% 1-1/2 6 GJL3600M02 400% 1300% GJL36015M03 00% 200% GJL36015M03 00% 2400% 5.6 GJL36015M03 600% 2200% 2.8 GJL36015M03 600% 2100% -1/2 9 GJL36015M03 500% 1800% GJL36015M03 500% 100% 3-1/ GJL36015M03 400% 1500% GJL36030M04 600% 2400% GJL36030M04 600% 2200% 15 1 GJL36030M04 500% 1900% GJL36030M04 500% 1900% GJL36030M04 400% 1600% -1/ GJL36030M04 400% 1500% -1/ GJL36030M04 400% 1300% GJL36050M05 600% 2000% GJL36050M05 500% 2000% GJL36050M05 500% 100% GJL36050M05 500% 100% GJL36050M05 400% 1600% GJL36050M05 400% 1400% GJL36050M05 400% 1300% GJL3605M06 400% 1300% GJL3605M06 500% 100% GJL3605M06 400% 1600% GJL3605M06 400% 1500% GJL3605M06 400% 1300% GJL3605M06 300% 1300% Table.68: Hp s of Induction Type Squirrel-Cage and Wound Rotor Motors 200 Vac 230 Vac 3Ø 60 Hz 460 Vac LL and ML djustable Instantaneous- Trip Circuit Breakers for Single Motor Circuit Protection 55 Vac Full Load sa Mag-Gard Circuit Breaker Magnetic Trip Settingsb MIN MX LL M 00% 1400% LL M 00% 1500% LL M 00% 1400% LL M 00% 1400% LL M 00% 1400% LL M 00% 1400% LL M 00% 1300% LL M 600% 1300% ML M 00% 1500% ML M 00% 1400% ML M 00% 1400% ML M 00% 1400% ML M 00% 1300% ML M 00% 1400% ML M 00% 1500% ML M 00% 1500% ML M 00% 1500% ML M 00% 1400% ML M 00% 1400% ML M 00% 1300% a Motor full-load currents are taken from NEC Table Select wire and circuit breakers on basis of horsepower rather than nameplate full-load current per NEC () for general motor applications. Do not use these values to select overload relay thermal units. See Digest pages for selection of thermal units when actual full load current is not known. The voltages listed are rated motor voltages. Corresponding nominal system voltages are , , and V. b Only MIN and MX settings are shown, intermediate settings are available on all circuit breakers. c See NEC () for circuit breaker settings above 800%. d If due to motor starting characteristics, trip settings at the 1300% maximum permitted level are needed, the next size Mag-Gard circuit breaker should be chosen Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

32 Motor Circuit Protectors Table.69: Motor Protection Selection Tables Class Selection Tables for Conductors, Safety Switches and Thermal-Magnetic Circuit Breakers Based on 2005 NEC Tables , & a 8 XHHW requires 3/4 in. conduit for 3W. b200 V motors are commonly used on 208 V services. cordinary service for normal starting duty only, acceleration time of 10 sec. or less. dheavy service is jogging or plugging duty or cycling load with over 25 starts per hour or over 5 starts per minute. Energy efficient motors are polyphase motors defined in NEM Standard MG1 and exhibit high starting current. enec for Single Motor, Smaller conductors may be permitted for light duty-cycle service per (B) Exception No. 1. DC motors operating from rectified 1Ø power supply will require larger conductors per () Exception No. 1. For motor-generator arc welders, see fmotor full load currents thru 200 hp are taken from NEC Tables , 148 and 150. bove 200 hp from UL 98. Select wire size, circuit breakers, or fuses on basis of hp rather than nameplate full load current per NEC Do not use these values to select overload relay thermal units. See Digest pages for selection of thermal units when actual full load current is not known. Voltages listed are rated motor voltages. Corresponding nominal system voltages are V, V, V, V and V. gswitch size only is shown in table. Selected fuses should not exceed maximum percent of full-load current as given in NEC Table bove 50 hp dc switches are not hp rated by UL as Motor Circuit Switches, but as General Use Switches only and are not necessarily capable of interrupting the max. operating overload current of a motor. See NEC 100 for definition of General Use Switch. When protecting a 3Ø, Design E energy efficient motor, the switch is required by NEC to have a hp rating of not less than 1.4 times that of a motor rated hp, or not less than 1.3 times that of a motor rated over 100 hp. Switches shown in this table do not necessarily comply with that requirement. hthermal-magnetic circuit breaker ampere ratings recommended are approximate for average conditions, based on trip characteristics of Square D circuit breakers and NEC Table Under some conditions, the next size larger switch or circuit breaker rating may be necessary to accommodate the motor starting current and is permitted by NEC (C)(1) Exception 2. High starting currents are anticipated with Design E and other energy efficient motors. For explanation of Code letter markings, see NEC 430.(B). For Busway Plugin units, see page 9-. ithermal-magnetic breaker ampere ratings recommended are approximate for average conditions and based on trip characteristics of Square D circuit breakers and NEC Tables 430.(B) and jtype LC, LI, LX, LXI, and LE circuit breakers are NOT recommended for use on single motor branch circuits. Contact your local Field Office for circuit breaker selection on constant horsepower multi-speed motors. Squirrel-Cage and Wound-Rotor Motors with Norm. Torque Characteristics Operating at Usual Speeds 200 Vacb 3Ø 60 Hz Horsepower s 1Ø 60 Hz ac verage Direct Current Motors Operating at Base Speed f Full Load mperage mperage of Thermal-magnetichj Inverse Time Circuit Breaker For Motor Code Letter B to E Heavy Service Ordinary and Energy Servicec Efficientd Schneider Electric This document provided by Barr-Thorp Electric Co., Inc For Motor Code Letter F to Vi Vac Vac Vac Vac Vacb Vac Vdc Vdc 3/ / / / / / / / / / / / / / / / / / / QMB and Heavy Duty Switch with Time Delay Fusesg Minimum Size Metallic Conduit 5 C, C Wire Field-Installed Sized for 125% FLe WG kcmil Conduit 3 W THHN THWN XHHW THW 14 1/2 in. N/ 12 1/2 in. N/ 10 1/2 in. N/ 8 1/2 in.a 3/4 in. 6 3/4 in. 1" 4 1 in. 1" 3 1 in. 1-1/4 in. 2 1 in. 1-1/4 in /4 in. 1-1/2 in. 1/0 1-1/4 in. 1-1/2 in. 2/0 1-1/2 in. 1-1/2 in. 3/0 1-1/2 in. 2 in /0 2 in. 2 in in. 2 in in. 2-1/2 in /2 in. 2-1/2 in in. 3 in (2) 3/0 (2) 1-1/2 (2) 2 in (2) 4/0 (2) 2 in. (2) 2 in (2) 300 (2) 2 in. (2) 350 (2) 2-1/2 in. (2) 2-1/2 in. (2) 2-1/2 in. (3) 300 (3) 2 in. (3) 2-1/2 in.

33 utomatic Switches Class 600 / Refer to Catalog 0612CT0101 utomatic molded case switches open instantaneously at a factory preset magnetic trip point, calibrated to protect only the molded case switch itself, when it is subjected to high fault currents. The trip point is nonadjustable and provides no overload or low level fault protection. Molded case switches open when the handle is switched to the OFF position or in response to an auxiliary tripping device such as a shunt trip. ll molded case switches will accept the same lugs and accessories as equivalent thermal-magnetic circuit breakers, with the exception of Q-frame switches which do not have electrical accessories available. utomatic molded case switches are UL Listed per UL 489 and are CS Certified. J-Frame Switch D-Frame Switch Table.2: Frame Poles P R Table.0: Poles H-Frame and J-Frame PowerPact utomatic Molded Case Switches, 600 Vac G Interrupting 150 HGL26000S15a HLL26000S L150HD 14 WG 3/0 WG l/cu 2 15 JGL26000S JLL26000S L15JD 4 4/0 WG l/cu 250 JGL26000S JLL26000S L250JD 3/0 WG 350 kcmil l/cu 150 HGL36000S HLL36000S L150HD 14 WG 3/0 WG l/cu 3 15 JGL36000S JLL36000S L15JD 4 4/0 WG l/cu 250 JGL36000S JLL36000S L250JD 3/0 WG 350 kcmil l/cu a True 2P device. Others are a 2P in a 3P module. Table.1: Circuit Breaker Poles 400 DJL36000S S WG 500 kcmil l or 2 WG 600 kcmil Cu D-Frame DJL36000S S32510 (2) 2/0 WG 500 kcmil l or (2) 2/0 WG 350 kcmil Cu QBL22000S22c Q-Frameb 4 WG 300 kcmil QBL32000S22c b Withstand rating of 10 k at 240 Vac. c DE2 discount schedule. 600 PJL26000S k PKL26000S k PLL24000S60d k 800 PJL26000S k PKL26000S k PLL24000S80d k 1000 PJL26000S k PKL26000S k PLL24000S10d k 1200 PJL26000S k PKL26000S k PLL24000S12d k 600 PJL36000S k PKL36000S k PLL34000S60d k 800 PJL36000S k PKL36000S k PLL34000S80d k 1000 PJL36000S k PKL36000S k PLL34000S10d k 1200 PJL36000S k PKL36000S k PLL34000S12d k 1200 RKF26000S k RLF26000S k 1600 RKF26000S k RLF26000S k 2000 RKF26000S k RLF26000S k 2500 RKF26000S k RLF26000S k 1200 RKF36000S k RLF36000S k 1600 RKF36000S k RLF36000S k 2000 RKF36000S k RLF36000S k 2500 RKF36000S k RLF36000S k 3000 RKF36000S k RLF36000S k d P-frame L-interrupting is available in 480 Vac only. e UL magnetic trip tolerances are -20% / +30% from the nominal values shown. 240 Vac 65 k 100 k 65 k 125 k 480 Vac 35 k 65 k 50 k 100 k 600 Vac 18 k 25 k 50 k 50 k f The withstand rating is the fault current at rated voltage that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. L Interrupting Trip Point Trip Point Terminal Wire Range D-Frame (600 Vac) and Q-Frame (240 Vac) PowerPact utomatic Molded Case Switches J Interrupting Trip Point Terminal P-Frame and R-Frame PowerPact utomatic Molded Case Switchese, 600 Vac J Interrupting K Interrupting L Interrupting Trip Point Trip Point Trip Point Table.3: Voltage H-, J-,- P-, and R-Frame Withstand sf Interrupting G J K L Table.4: Voltage Wire Range Terminal L800M23K L1200P25K L800M23K L1200P25K Wire Range (3) 3/0 WG 500 kcmil l or Cu (4) 3/0 WG 500 kcmil l or Cu (3) 3/0 WG 500 kcmil l or Cu (4) 3/0 WG 500 kcmil l or Cu R-frame circuit breakers can be bus-connected or cable-connected. For cable connections, RLTB kit or equivalent bus structure is required. Kit is included with 3000 switches. For all others, see page -41. D-Frame Withstand sg Interrupting J 240 Vac 150 k 480 Vac 100 k 600 Vac 25 k g The withstand rating is the fault current at rated voltage that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. ccessories page -36 and Supplemental Digest Optional Lugs Page -39 and Supplemental Digest Dimensions Pages -54 and -55 Enclosures Pages Schneider Electric DE2 DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

34 500 Vdc Circuit Breakers UL Listed 500 Vdc Circuit Breakers Class 500, The UL Listed thermal-magnetic molded case circuit breakers shown below are specifically designed for use on ungrounded dc systems having a maximum short-circuit voltage of 500 Vdc or a maximum floating (unloaded) voltage of 600 Vdc. The circuit breakers are suitable for use only with UPS (uninterruptable power supplies) and ungrounded systems. This two-level voltage rating allows these circuit breakers to be applied to battery sources having a short-circuit availability of 20,000 amperes for FH, KH, LH, and MH circuit breakers and 25,000 amperes for PF circuit breakers at 500 Vdc. FH, KH, LH and MH circuit breakers are provided with an adjustable magnetic trip that is readily accessible by means of a single adjustment on the face of the circuit breaker. PF circuit breakers have a fixed magnetic trip range. These circuit breakers are UL Listed for the interrupting ratings shown only if applied with three poles connected in series (series connection is external to circuit breaker). See diagram below. NOTE: Due to external series connection, I-Line circuit breakers are not available for this application. CUTION/PRECUCION/ TTENTION Connect only as shown/conectar solo asi/ Francher seulement comme suit: 300 V 300 V MX. MX. or o ou 600 V MX. Load/Carga/ Charge Load/Carga/ Charge Source = 600 Vdc max. (floating) 500 Vdc max. (loaded) New! Table.5: DC Molded Case Circuit Breakers Circuit Breaker djustable Magnetic Trip Range DC sa Low High 500 Vdc 100 JGL3100D JGL3125D k IR 150 JGL3150D JGL315D JGL3200D JGL3225D k IR JGL3250D FHL DC FHL DC k IR FHL DC LHL DC LHL DC k IR 350 LHL DC LHL DC MHL DC MHL DC MHL DC MHL360035DC k IR MHL DC MHL DC MHL DC MHL DCb k IR Circuit Breaker Fixed Magnetic Trip RangeDC sa Hold 500 Vdc 1200 PF361200DC PF361600DC k IR PF362000DC PCF362500DC k IR a Magnetic trip tolerances are -20%/+30% from the nominal values shown. b Suitable for use only in a ventilated enclosure. Minimum enclosure dimensions are 38" h x 20" w x " d with a minimum of 300 square inches of ventilation near the top and bottom of the enclosure. Trip ccessories Page -36 and Supplemental Digest Optional Lugs Page -39 and Supplemental Digest Dimensions Pages -54 and -55 Enclosures Pages Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

35 New! New! Molded Case Circuit Breakers Mission Critical Circuit Breakers Continuity of service is important for most industrial and commercial customers. To ensure maximum continuity of service, electrical distribution systems are typically selectively coordinated in order to restrict outages to the circuit or equipment affected by an overload or short-circuit. In order to ensure maximum continuity of service, Square D has developed a line of Mission Critical circuit breakers to ensure selective coordination. Compact NSF250MC Mission Critical Circuit Breakers The Compact NSF250MC Mission Critical Circuit Breakers are specifically designed to provide coordination with QO miniature circuit breakers during a short-circuit conditions. When the NSF-MC circuit breaker is used as a main circuit breaker with QO branch circuit breakers, the NSF-MC circuit breaker will remain closed during any fault that occurs downstream of the QO circuit breaker up to 35 k at 208Y/120 Vac. Table.6: Circuit Breaker Compact NSF250MC Mission Critical Circuit Breakers (208y/120 Vac ratings at 65 k) Magnetic Trip Level Terminal Wire Range NFNL32225W kcmil Cu or l NFNL32250W kcmil Cu or l NFNL32225WLY /0 WG NFNL32250WLY /0 WG NFNF32225W /4-20 bolt for bus bar NFNF32250W /4-20 bolt for bus bar L Mission Critical Circuit Breakers The L High Magnetic Withstand MC Circuit Breakers are designed to trip at a higher magnetic trip level (18 20 times handle rating) than typical molded case circuit breakers (MCCBs) (which trip at 5 10 times the handle rating). The high magnetic withstand value of these L circuit breakers allow the downstream branch circuit breaker to clear the fault. Table.: L-Frame400, Thermal-Magnetic, High Magnetic Withstand Circuit Breakers For Mission Critical Loads C Magnetic Level Factory Set Standard Interrupting High Interrupting Terminal Hold Trip Wire Range L/LH MC Circuit Breaker, 3P, 480 Vac LL34200MC LHL34200MC LL34225MC LHL34225MC L250LMC LL34250MC LHL34250MC LL34400MC LHL34400MC L400L (1) kcmil l (1) 3/0 WG 350 kcmil Cu (1) 1 WG 600 kcmil l or (2) 1 WG 250 kcmil l PowerPact D-frame Mission Critical Circuit Breakers When the D-frame Mission Critical circuit breaker is used as a main circuit breaker with QO branch circuit breakers, the D-frame MC will remain closed during any fault that occurs downstream of the QO circuit breaker up to 30k at 208Y/120 Vac. Circuit Breaker a Continuous Current Terminal Wire Range (WG/kcmil) DJM32150W DJM32250W 250 #2-600 Cu or #2-500 l DJM32400W DJM32600W 600 (2) 2/0-350 Cu or (2) 2/0-500l a D-Frame circuit breakers 400 and below are 100% rated. PowerPact Circuit Breakers with Micrologic Electronic Trip Units The advantages of being able to adjust the trip curve of a circuit breaker equipped with an electronic trip system are obvious. There are other advantages, such as being able to adjust or turn off the instantaneous trip function on some circuit beakers and models of trip units. ccessories Supplemental Digest Compression and Power Distribution Connector Lugs. Supplemental Digest Dimensions Page -54 Enclosures Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

36 PowerPact Circuit Breaker ccessories Electrical ccessories Class 612 / Refer to Catalog 0612CT Table.8: Electrical ccessories ccessory Description Rated Voltage uxiliary and larm Switches (OF, SD, SDE) H-, J-, D-, M-, P, and R-Frame H-, J-, and D-Frame H-, J-, and D-Frame Time Delay Unit Shunt Trip (MX) Undervoltage Trip G-Frame G-Frame G-Frame Provides circuit breaker contact status. Note: The location of the accessory in the circuit breaker determines its function. Standard Min Load = 10m with 24V Low Level Min Load = 1m with 24V G-Frame H-, J-, and D-Frame M-, P-, and R-Frame Field- Installable Installed Factory- Cat. Suffix H- and J-Frame D-Frame Field- Installable Field- Installable Factory Field- Installed Installable Cat. Suffix 1 auxiliary switch (OF) 1a1b C S S S auxiliary switch (OF) 2a2b B 2x S x S B 2x S auxiliary switch (OF) 3a3b C 3x S C 3x S larm Switch (SD) 1a1b C BC S S BC S Overcurrent trip switch (SDE) 1a1b Consisting of: larm switch and Overcurrent trip switch BD S BD S OF Switch S SDE dapter S BE x S BE 2x S OF Switch 2x S Consisting of: SDE dapter S uxiliary Switch/larm S33801c Switch/dapter (OF/SD/SDE) Kit One auxiliary switch (OF) 1a1b E S S E S Two auxiliary switches (OF) 2a2b F 2x S x S F 2x S auxiliary switches (OF) 3a3b G 3x S G 3x S larm Switch (SD) 1a1b BH S S BH S Overcurrent trip switch (SDE) 1a1b Consisting of: BJ S BJ S OF Switch S SDE dapter S larm switch and Overcurrent trip switch BK x S BK 2x S Consisting of: OF Switch 2x S SDE dapterd S SK S29384 S29384 SK S SL S29385 S29385 SL S GS 110/130 S S29386 S29386 S S GSB C 240 GSC /250 SC S Trips the circuit 2 GSD breaker from a remote 208/2 SD S2938 S2938 SD S33663 location by means of a 480 GSH trip coil energized from a separate supply 380/480 SH S29388 S29388 SH S33664 voltage circuit. 525/600 SJ S29389 S SN S29382 S29382 SN S GSO SO S29390 S29390 SK S SU S29391 S29391 SK S33659 DC 48 GSP 1.00 SP S S SL S SV S29383 S29383 SL S GSR SR S29393 S29393 S S GSS SS S29394 S29394 SC S UK S29404 S29404 UK S33668 Instantaneously opens the circuit breaker when the under-voltage trip supply voltage drops to a value between 35% and 0% of its rated voltage. Closing is allowed when the supply voltage of the undervoltage trip reaches 85% of rated voltage. Undervoltage trip with externally mounted adjustable time delay unit for UVR of 0.5, 0.9, 1.5, 3.0 seconds before circuit breaker trips Undervoltage trip with externally mounted non-adjustable time delay unit of 0.25 sec before circuit breaker trips. C DC C/DC C/DC a Field-installable kit includes time delay module only. Order undervoltage trip separately. b Discount schedule DE2F. c P-frame drawout circuit breaker only. d SDE dapter used for H- and J-frame only. 48 UL S29405 S29405 UL S GU 110/130 U S29406 S29406 U S GUB 240 GUC /250 UC S GUD 208/2 UD S2940 S GUH 380/480 UH S29408 S29408 UH S /600 UJ S29409 S UN S29402 S GUO UO S29410 S29410 UK S UU S29411 S29411 UK S GUP 1.00 UP S S UL S UV S29403 S29403 UL S GUR UR S29413 S29413 U S GUS US S29414 S29414 UC S /60 FL S33680a b 100/130 F S33681a b S33682a 200/250 FC b 380/480 FH S33683a b 100/130 K S33684a b 200/250 KC S33685a b Schneider Electric DE2 DE2F Discount This document provided by Barr-Thorp Electric Co., Inc

37 Table.9: Motor Operator Table.80: Spring-charging Motor Table.81: PowerPact Circuit Breaker ccessories Motor Operators for H-, J-, and D-Frame Circuit Breakers Description Rated Voltage Factory Installed Suffix Motor Operators and Rotary Handles Class 612 / Refer to Catalog 0612CT0101 Field--Installable Kit H-Framea J-Frame D-Frame 400 D-Frame /60 ML S29440 S /130 M S29433 S /2 MD S29434 S C 220/240 MC /415 MF Standard motor for 380/485 MH S29435 S31542 electrically-operated circuit breakers 440/480 MH /30 MO S29436 S /60 MP S2943 S DC 48/60 MV /130 MR S29438 S MS S29439 S Mounting Hardware Locking Device Ronis lock Profalux lock Operations Counter dapter for I-Line S S Spring-Charging Motors for Electrically-Operated P-Frame Circuit Breakers Description Standard motor for electricallyoperated circuit breakers. Factory-installed includes motor and opening/closing coils. Communicating motor mechanism for electrically operated circuit breakers. Factory-installed includes motor and opening/closing coils. Rotary Operated Handles Device C DC C DC Description Rated Voltage Factory Installed Suffix P-Frame (For Field-replacement Only) Spring Charging Motor c Replacement Coils Opening/Closing Coil 48 ML S4391 S /130 M S4395 S /240 MC S4396 S /415 MF S4398 S /30 MO S4390 S /60 MV S4391 S /130 MR S4392 S /250 MS S4393 S NL S4391 S /130 N S4395 S /240 NC S4396 S /415 NF S4398 S /30 NO S4390 S /60 NV S4391 S /130 NR S4392 S /250 NS S4393 S33036 H- and J-Framea D-Frame P-Frame Factory Field Installed Installable Suffix Factory Installed Suffix Field Installable Factory Installed Suffix Standard Handle Black Handle only RD10 S RD RD Two early-break and two early make switches RD Standard Black Handle with One early-break switch RD12 S S Two early-make switches RD13 S Direct S Mounted RD20 S RD One early-break switch RD22 S Red handle on yellow bezel S Two early-make switches RD23 S S MCC Conversion ccessory Standard black handle Handle Only RE10 S RE RE Two early-break and two early make switches RE Door Standard Black Handle Mounted with: S Two early make switches RE13 S Red handle on yellow bezel Handle Only RE20 S RE Rotary Handle Replacement Kit S Telescoping RT10 S RT Key lock adapter Ronis Key locks ccessories Profalux KS5 B24 D4Z Indication uxiliary Switch One early-break switch Two early-make switches Direct-Mounted handle Door-Mounted Handle a Not available in H-frame 2P modules. b CP1 discount schedule. c DE2F discount schedule Schneider Electric DE2F CP1 DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

38 PowerPact Circuit Breaker ccessories Table.82: Device Handle Padlocking Device Locks, Interlocking Description Locks, Installation ccessories, and Rear Connections Class 612 / Refer to Catalog 0612CT G-Frame H- and J-Frame Q-Frame D-Frame M- and P-Frame R-Frame Field- Installed Field- Installed Field- Installed Field- Installed Factory Installed Suffix Field- Installed Factory Installed Suffix Field- Installed Removable (lock OFF only) HP 19.0 S S S S Fixed (lock OFF or ON)a S QBP.00 S YP S YP S Fixed (lock OFF only) S QBPF.00 NJPF YQ MPRPF YQ MPRPF Mechanical for circuit breakers with rotary Interlocking S S handlesa (Not UL listed) Mechanical for circuit breakers with togglesa S QBMIK Provision only, vertical mount, 1 or 2 locks Kirk or Federal Pioneer J Provision only, horizontal Kirk JK JK mount Federal Pioneer JR JR Key Locking 1 lock, M- and P-frame Ronis JB JB or 2 locks, R-frame Profalux JD JD Provision and 1 lock, Kirk JG vertical mount Federal Pioneer JH Kirk JL JL Provision and 1 lock, Federal Pioneer JS JS horizontal mount Ronis JC JC Profalux JF JF Kirk JN JN Provision and 2 locks Federal Pioneer JV JV keyed alike Ronis Profalux Provision and 2 locks Kirk JP JP keyed differently Federal Pioneer JW JW a Not available in M frame or HD and HG 2P modules. Handle Rubber Boot Terminal Covers Table.85: Device Removable Padlock ttachment Door Escutcheon Rear Connection Fixed Padlock ttachment Rear Connections Description Poles Factory- Installed Termination No. Table.83: Installation ccessories for G-, H-, J-, and D-Frame Circuit Breakers Description H- and J-Frame G-Frame D-Frame Field- Installed Field- Installed Field- Installed Front Panel Escutcheon for Toggle Breakers S Front Panel Escutcheon for Rotary Handle, Motor Operator, or extended escutcheon S Phase Barriers (set of 6) S Handle Rubber Bootb S Sealing ccessories CS DIN rail mounting kit (requires 15 mm depth on a 35 mm DIN rail)b S DIN rail adapter GYR Toggle Extensions (set of 10) S b Not available in HD and HG 2P modules. Table.84: Installation ccessories for M-, P-, and R-Frame Circuit Breakers Description Frame Field- Installed M-, P-Frame S3318c ccessory Cover R-Frame S Door Escutcheon Toggle Handle M-, P-Frame S Drawout P-Frame S3385c Short lug cover 3P S Terminal Covers Short lug cover 4P S P-Frame Long lug cover 3P S Long lug cover 4P S Standard R-Frame S Replacement Handle Standard Short M-, P-Frame S Long M-, P-Frame S c DE2F discount schedule. H-Frame J-Frame D-Frame Field- Installable Poles Factory- Installed Termination No. Field- Installed Poles Factory- Installed Termination No. Field- Installed Mixed Rear 2 S S S Connection Kit 3 S S S S S Short rear connections (set of 2) 2x S3433e x S3438e x 3245e or 3 2 or 3 3 Consisting of: Long rear connections (set of 2) S S3439d Short terminal cover (3P) 3 S S d For use with 3P circuit breakers only. e Price shown is for quantity one Schneider Electric DE2 DE2F Discount This document provided by Barr-Thorp Electric Co., Inc

39 PowerPact Circuit Breaker ccessories Mechanical Lugs Class 612 / Refer to Catalog 0612CT0101 J-Frame Lug D-Frame Lugs Table.86: l Lugs for Use with l or Cu Wire Cu Lugs for Use with Cu Wire Only Mechanical Lug Kits for H-Frame and J-Frame Circuit Breakersa Circuit Breaker pplication Standard Optional Number of Wires Per Lug and Wire Range Kit Qty Per Kit Per Kit HD, HG, HJ, HL (1) 14 3/0 WG l or Cu L150HD JD, JG, JJ, JL (1) 4-4/0 WG l or Cu L15JD JD, JG, JJ, JL JD,JG,JJ,JL (1) 3/0 350 kcmil l or Cu L250JD HD,HG,HJ,HL (1) 14 2/0 WG Cu CU150HD JD,JG,JJ,JL (1) 1/0 300 kcmil Cu CU250JD Control Wire Terminal for H-frame lug kit S Control Wire Terminal for J-frame lug kit S a See page -41 for terminal nuts/bus bar connections. Table.8: Mechanical Lug Kits for D-Frame Circuit Breakers Description Poles 400 Lugs 600 Lugs Field-Installable Lug Kit, Terminal Cover Included Voltage Takeoffs (set of two) Wire Range (1) 2 WG-600 kcmil stranded CU cable (1) 2 WG-500 kcmil stranded L cable (2) 2/0 WG-350 kcmil stranded CU cable (2) 2/0 WG-500 kcmil stranded L cable M- and P-Frame Lugs (800 and below) P-Frame Lugs (bove 800 ) Table.88: l Lugs for L or Cu Wire New! Cu Lugs for Cu Wire Only Mechanical Lug Kits for M-Frame, P-Frame and R-Frame Circuit Breakerse Circuit Breaker pplication Standard Optional Wires per Lug and Wire Range Lugs Per Kit Per Kit L800M23K (3) 3/0 WG-500 kcmil L800M23K PG,PJ,PL,MG,MJ 800 (4) 3/0 WG-500 kcmil L1200P24Kb M-, P-Frame L800P6Kb PG,PJ,PL,MG,MJ 800 (2) 3/0 WG-600 kcmil L800P6K4b New! PG,PJ,PL 800 (2) 3/0 WG-50 kcmil L800PKb kcmil: compact L only L800PK4b L1200P25Kc PG,PJ,PL 800 (4) 3/0 WG-500 kcmil L1200P25K4c P-Frame L1200P6KUc PG,PJ,PL (3) kcmil L1200P6KU4c (3) 3/0 WG-50 kcmil L1200PKUc PG,PJ,PL PG,PJ,PL kcmil: compact L only L1200PKU4c I-Line (4) 3/0 WG-600 kcmil L1200R53K R-Frame 2500 Unit Mount (1) 3/0 WG-50 kcmil L2500RKd PJ (1) 1-1/0 WG CU250P1Kf CU800M23K M-, P-Frame 800 MG, MJ, PG, PJ, PL (3) 3/0 WG-500 kcmil CU800M23K MG, MJ, PG, PJ, PL (4) 3/0 WG-500 kcmil CU1200P24Kb CU1200P25Kc P-Frame 1200 PG,PJ,PL (4) 3/0 WG-500 kcmil CU1200P25K R-Frame 1200 I-Line (4) 3/0 WG-500 kcmil CU1200R53K b Does not fit onto ON end of unit-mount P-frame circuit breakers. c For unit-mount circuit breaker only. d ll unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page -41. e For lug with a tapped hole for control wire, add a T before the K in the catalog number (for example, L800P6TK). f This lug can only be used on low amp PJ frame breakers where the Instantaneous setting must not be turned OFF. The cables must be laced with rope per lug instructions Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

40 PowerPact Circuit Breaker ccessories Compression Lugs and Power Distribution Connectors (PDC) Class 612 / Refer to Catalog 0612CT J-Frame Compression Lugs P-Frame Compression Lug Kit R-Frame Compression Lug Kit PDC6HD6 PDC3HD2 PDC12P4 PDC6JD4 PDC3JD20 PDC6P20 Crimp lug or power distribution connectors extension past end of circuit breaker See Table Table.89: Compression Lug Kits for PowerPact Circuit Breakers Circuit Breaker Type System Range Compression Lug Kits for H-Frame and J-Frame Circuit Breakers luminum Compression Lug Kits Copper Compression Lug Kits H-frame J-frame H-frame J-frame Compression Lug Kits for D-Frame Circuit Breakers Not vailable Mounting Type Compression Lug Kits for M-Frame, P-Frame, and R-Frame Circuit Breakers luminum Compression Lug Kits Copper Compression Lug Kits M-, P-framec R-frameac M-, P-framec Dimension (in) Max. Lugs per Terminal R-framec I-Line kcmil CY1200R a ll unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page -41. b 9 lugs for 3000 circuit breakers c Not for use on I-Line circuit breakers unless wire bending space is adequate. Table.90: Use with Circuit Breaker Type HD, HG, HJ, HLd (6) 14 6 WG Cu 1.0 PDC6HD (3) 14 2 WG Cu 1.2 PDC3HD JD, JG, JJ, JLd (6) 14 4 WG Cu 1.0 PDC6JD (2) 14 1 and (1) 12 2/0 WG Cu 1.5 PDC3JD DG, DJ, DL (3) 14 2 WG and (2) 14 2/0 WG 1.28f PDC5DG (12) 14 4 WG 1.31f PDC12DG d OFF end only when OFF end is the load end. Table.91: e Not for use with I-Line circuit breakers. f Kit includes long terminal shield and cover, which adds 1.65 inches to standard lug with short terminal shield. Lugs Per Kit Per Kit 6 2 WG l or Cu Y060HD /0 4/0 WG l or Cu Y150HD /0 WG l or Cu Y150JD /0 350 kcmil l or Cu Y250J Unit 6 1/0 WG Cu CY060HD /0 WG Cu CY150HD /0 WG Cu 0. 1 CY150JD /0 300 kcmil Cu CY250J /0-300 kcmil 3. 2 Y250P /0-500 kcmil Y300P /0-300 kcmil Y400P Unit kcmil 3. 2 Y400P /0-500 kcmil Y600P kcmil Y800P /0-300 kcmil Y1200R /0-500 kcmil I-line Y1200R kcmil Y1200R /0-300 kcmil a 8 Y2000R Unit 4/0-500 kcmil a 8 Y2000R kcmil a 8b Y2500R /0-500 kcmil CY400P /0-500 kcmil Unit CY600P kcmil CY800P /0-500 kcmil CY1200R Power Distribution Connectors for H-Frame, J-Frame and D-Frame Circuit Breakers Circuit Breaker Wires Per Terminal & Wire Range Dimension (in.) Quantity Per Kit Per Kit Power Distribution Connectors for M-Frame and P-Frame Circuit Breakerse Use for multiple load connections on one circuit breaker in place of standard distribution block to save space and time. Use on load end of circuit breaker only Use in UL508 Industrial Control applications only. Use in UL1995/CS C22.2 No. 236 heating and cooling equipment. For Cu wire only (Wires Per Terminal) Wire Range (6) 3 2/0 WG Cu (6) 6 4 WG Cu (6) 8 WG Cu (6) WG Cu (12) 6 4 WG Cu (12) 8 WG Cu (12) 10 WG Cu Qty Per Kit Per Kit PDC6P PDC6P PDC12P PDC12P Extremity of Molded Case w/mechanical Lugs See Table Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

41 Terminal Nut Insert PowerPact Circuit Breaker ccessories Table.92: Terminal Nuts, Terminal Pads, Terminal Shields and ccessories Class 612 / Refer to Catalog 0612CT0101 Terminal Nuts for Bus Bar Connection of H-Frame and J-Frame Circuit Breakers Description Frame Tap Qty Per Kit Per Kit H-Frame Terminal Nut Insert English HD/HG/HJ/HL 1/4-20 S H-Frame Terminal Nut Insert English HD/HG/HJ/HL 1/4-20 S H-Frame Terminal Nut Insert Metric HD/HG/HJ/HL M6 S J-Frame Terminal Nut Insert English JD/JG/JJ/JL 1/4-20 S J-Frame Terminal Nut Insert English JD/JG/JJ/JL 1/4-20 S J-Frame Terminal Nut Insert Metric JD/JG/JJ/JL M8 S Control Wire Terminal for H-Frame Terminal Nut HD/HG/HJ/HL S Control Wire Terminal for J-Frame Terminal Nut JD/JG/JJ/JL S H-Frame Lug With Terminal Nut Table.93: Bus Bar Connections Hardware for D-Frame, M-Frame and P-Frame Circuit Breakers Frame Description Term. No. Poles Set of 3 terminal screws and washers for one side D-Frame Set of 4 terminal screws and washers for one side F M- and P-Frame Bus Connector Kit for one pole, one end 1 S H-Frame Short Lug Shield Phase barrier or terminal shield extension past end of circuit breaker B See Table Extremity of Molded Case w/mechanical Lugs RLTB Terminal Pad Kit J-Frame Short Lug Shield R-Frame Phase Barrier Table.94: R-Frame Circuit Breaker Terminal Pad Kits for R-Frame Circuit Breakers Terminal Pad Kit Usage Lugs per Phase 3P Kit (One End Only) For cable connection to RLTB, use L2500RK lug. See page -40. Field-Installable Kits 4P Kit (One End Only). 3000, 100% Rated Required for cable or bus 9 RL3TB RL3TB , Standard (80% Rated) Required for cable or bus 2500, 100% Rated Required for cable or bus 2500, Standard (80% Rated) Required for cable, optional for bus 8 RLTB RLTB ll Other R-Frame CIrcuit Breakers Required for cable, optional for bus Table.95: Used With H- and J-Frame Mechanical Lugs H- and J-Frame Power Distribution Connectors and Compression Lugs G-Frame D-Frame Terminal Shields and Phase Barriers Short Lug Shielda H-Frame Long Lug Shield J-Frame Long Lug Shield Terminal Shield (3P) Terminal Shield (3P) Description Dimension B (in.) Qty Per Kit Frame Max. Wire Size H-Frame 60 3 WG 0.50 S H-Frame 150 3/0 WG 0.50 S J-Frame 350 kcmil 0.24 S Compatible with: PDC Compression Lugs luminum Copper PDC6HD6 Y060HD CY060HD PDC3HD2 Y150HD CY150HD 2.24 S PDC6JD4 Y150JD CY150JD PDC3JD2 b CY250J S GYT PDC5DG2 PDC12DG M-, P-Frame S Phase Barriers 3 R-Frame S a Short lug shields provide IP20 protection for mechanical lugs and are compatible with control wire terminals. b J-frame terminal shield is not compatible with the Y250J35 compression terminal. B See Table Table.96: ccessory Miscellaneous D-Frame Circuit Breaker ccessories Description Field-Installed Cat. No, 150 Neutral Sensor External Neutral Sensor 250 Neutral Sensor Neutral Sensor Neutral Sensor Spare Parts 100 Identification Labels Test Kits Mini test kit (battery not included) Portable test kit 55391c c DE5 Discount Mini Test Kit Portable Test Kit 2009 Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

42 PowerPact Circuit Breaker ccessories H-Frame and J-Frame Plug-in Mounting D-Frame Plug-In Mounting D-Frame Disconnecting Blocks P-Frame Drawout Cradle Connections H-Frame and J-Frame Drawout Mounting D-Frame Drawout Mounting D-Frame Locking Device Plug-In and Drawout Mountings Class 611, 615 / Refer to Catalog 0611CT0401, 0615CT9901 Table.9: Complete Factory-ssembled Circuit Breakers Special Order Options for Plug-In and Drawout Circuit Breakers ccessories for Plug-In and Drawout Table.98: Plug-In and Drawout Mountings for H- and J-Frame Circuit Breakers (3P or 2P in a 3P module) Description Factory Installed Field- Installed Plug-in base shipped with circuit breaker N Drawout cradle shipped with circuit breaker D Plug-In Base Circuit breaker Only HJ Plug-in base kit S Circuit breaker only HJ Plug-in base kit S Drawout Cradle Cradle side plates (fixed part of chassis) S Circuit breaker side plates (moving part of chassis) S H-Frame Shutter Kit (set of two) S J-Frame Shutter Kit (set of two) S Fixed part 9-wire connector (mounted on Secondary base) S Disconnect Moving part 9-wire connector (mounted on Blocks circuit breaker) S Support for 2-moving connectors S Extended escutcheon with extended toggle handle S Two position indicating switches (connected/disconnected) S Plug-In and Drawout Mountings for D-Frame Circuit Breakers Description Poles Factory Installed Plug-in Mounting Field- Installed Factory Installed Drawout Mounting Field- Installed Kit (stationary and moving parts) 3 N D N M D M Plug-in base Stationary Part 4 M M Fixed part of chassis HJ HJ Moving part of chassis Moving Part Short terminal covers Power connections 3 3x 32518a x 32518a x 32518a x 32518a a Price shown is for quantity of 1. Table.99: Plug-In and Drawout ccessories for D-Frame Circuit Breakers Description Field- Installed Fixed Part 9-wire connector Secondary Disconnecting Blocks 9-wire connector Moving Part Support for 3 moving connectors Shutters Two shutters for plug-in base Extended escutcheon for toggle Chassis ccessories Locking device (key lock is not included) Two position indicating switches (connected/disconnected) Table.100: Termination Options Termination Letter N = Plug-in D = Drawout For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number. D G L E 2 0 Termination No. HJ00 Options Code Suffix H = Plug-in or Drawout J = No Stationary Part 0 = No Switches 0 = No Shutters Table.101: Drawout Cradle and ccessories for P-Frame Circuit Breakers Description Drawout Cradle Product Selector Cradle Front Connected Flat (FCF) SFCF12bc Connectors Rear Connected T Horizontal/Vertical (RCTH/RCTV) SRCTV12bc Modbus cradle communication module S Safety shutters S48933c Secondary disconnects terminal shield S3363c Cradle position switch 1a/1b Form C Connected/test/disconnected S3310c Low level cradle position switch 1a/1b Form C Connected/test/disconnected S3311c Cell keying kit S336c 9.00 Cradle Disconnected position key lockingprovision for Kirk or Federal Pioneer Lock S332c ccessories Door interlock kit S3386c Racking interior kit S3388c Door escutcheon (for replacement only, included with circuit breaker) S3385c Transparent cover S33859c Push-in terminal kit (3 wires) S33098c Push-in terminal kit (6 wires) S33099c Finger cluster S33166c Cluster grease (12 oz. tube) S48899c b Needs 2 kits per cradle. c Discount DE2F Schneider Electric DE2 DE2F Discount This document provided by Barr-Thorp Electric Co., Inc

43 Standard Trip Unit mmeter Trip Unit Micrologic Electronic Trip Units Micrologic Trip Units Power Trip Unit Harmonic Trip Unit PowerPact P- and R-frame molded case circuit breakers may be specified with any of the following Micrologic Electronic Trip Units. Micrologic (Standard) 3.0 and 5.0 Trip Units True RMS sensing LI, LSI trip configurations Field-interchangeable long-time rating plugs LED long-time pickup indication Test kits available Thermal imaging Micrologic (mmeter) 3.0, 5.0 and 6.0 Trip Units Includes all features listed for Micrologic standard trip unit, as well as: LSIG trip configurations Digital ammeterphase and neutral (4-pole only) Phase loading bar graph LED trip indication Zone-selective interlocking (ZSI) (short-time & ground-fault) Optional Modbus communicationspowerlogic compatible Micrologic (Power) 5.0P and 6.0P Trip Units Power measurement and advanced protection features includes all features listed for Micrologic ammeter trip unit, as well as: LSI trip configuration with programmable ground fault alarm LSIG (Ground-fault trip) with programmable ground fault alarm Incremental fine tuning of L, S, I, and G pickup and delay settings LCD dot matrix display and LED trip indication dvanced user interface dvanced protection IDMTLselectable long-time delay bands Neutral protection Power measurement Contact wear indication Modbus communicationspowerlogic compatible Local and remote settings Class 612 / Refer to Catalog 0612CT0101 Micrologic (Harmonic) 5.0H and 6.0H Trip Units Power quality measurement and advanced protection features. Includes all features listed for the Micrologic power trip unit, as well as: Enhanced power measurements functions Power quality measurements Table.102: Micrologic Trip Units Features x Standard Feature o vailable Option Standard mmeter Power Harmonic P 6.0P 5.0H 6.0H LI x x LSI (Instantaneous can be turned off) x x x x x x x LSIG / Ground-Fault Tripa x x x Ground-Fault larm (No Trip) ab x x Ground-Fault larm and Trip a x x djustable Plugs x x x x x x x x x True RMS Sensing x x x x x x x x x UL Listed x x x x x x x x x Thermal Imaging x x x x x x x x x Phase Loading Bar Graph x x x x x x x LED for Long-time Pickup x x x x x x x x x LED for Trip Indication x x x x x x x Digital mmeter x x x x x x x Zone-selective Interlocking x x x x x x x Communications o o o x x x x LCD Dot Matrix Display x x x x dvanced User Interface x x x x Protective Relay Functions x x x x Neutral Protection x x x x Contact Wear Indication x x x x Incremental Fine Tuning of Settings x x x x Selectable Long-time Delay Bands x x x x Power Measurement x x x x Power Quality Measurements x x Waveform Capture x x a Requires neutral current transformer in 3Ø4W systems. b Requires M2C or M6C Programmable Contact Module. Table.103: Micrologic Trip Unit and Options Model Protection dditional Features Field-Installable c Kit / Circuit Breaker dder 2.0 (IEC only) LSO S132R (UL/NSI only) LI None S LSI S (IEC only) LSO S142Rd (UL/NSI only) LI S141d mmeter 5.0 LSI S143d LSIG S144d P LSI S163de Metering, dv. Protection 6.0P LSIG S164de H LSI Metering, dv. Protection S13de H LSIG & Harmonic nalysis S14de c The standard rating plug supplied with a trip unit will be the rating plug. To specify an alternative adjustable rating plug, please add the letter designation to the end of the catalog number. Please refer to page -44 for a complete listing of adjustable settings available with each plug. (Example: S143B would specify a B rating plug instead of the standard "" plug.) Use suffix N if no rating plug is required, deduct $ from the complete trip unit kit price. d When replacing a standard trip unit with Type (mmeter), P (Power metering) or H (Harmonic analysis) trip unit, order the 12-pin connector kit S33101 for the Masterpact NW and NT and the PowerPact P-frame drawout circuit breakers or kit S33100 for PowerPact P-frame and R-frame unit-mount and I-Line circuit breakers. See page -44. e Requires Circuit Breaker Communications Module Schneider Electric DE2F Discount This document provided by Barr-Thorp Electric Co., Inc

44 Micrologic Electronic Trip Unit djustable Plug Full Function Test Kit Sensor Plug Trip Unit Seal New! New! djustable PlugsSelection To provide maximum design flexibility, system protection, and field upgradeability, each Micrologic trip unit is equipped with an interchangeable long-time rating plug. Each trip unit requires an adjustable rating plug to determine the long-time pickup range of the circuit breaker. These plugs are factory installed on new trip units, or can be ordered separately for field-installable upgrades. djustable rating plugs are offered in eight different ranges of long-time pickup adjustments. The following chart show the ranges of adjustments. Each adjustment times the sensor rating (lr X In) of the circuit breaker sets the long-time pickup value of the circuit breaker. Table.104: Long-time Pickup Settings Plug Long-time Pickup Settings B C D E F G H djustable rating plug "" is installed as standard on all Micrologic trip unit orders. However, an alternative selection may be specified from the "ssembled" table below, and factory installed with your trip unit order at no additional charge. To order, please attach the appropriate catalog suffix to the end of the trip unit (after specifying trip unit options). djustable rating plugs may also be purchased as field-installable components from the table below. Table.105: Plugs Pluga Factory-Installed Field-Installable Cat. Suffix dder b (standard) N/C S B B N/C S C C N/C S D D N/C S E E N/C S F F N/C S G G N/C S H H N/C S a Long-time pickup amperes (Ir) = Sensor (In) X Setting of rating plug. Fine adjustment tuning is included on Micrologic Power and Harmonic trip units, allowing for incremental settings of 1 between the plug setting and.40 X Sensor. b DE2F Discount Table.106: Neutral Current Transformers For Use with Circuit Breaker c Sensor P-Frame S3355d S3356d S48916d R-Frame S34036d S48896d S48182d ll NCTWIRING ll c DE2F Discount d Includes NCTWIRING kit. Table.10: Special Options Description Ship circuit breaker in closed position Factory-Installed Suffix Field-Installable Micrologic Trip Unit ccessories Class 612 / Refer to Catalog 0612CT0101 YK N/ N/C Table.10: Special Options CT Characterization (Calibrated trip system) Table.108: Trip Unit ccessories Q N/ Device h Hand-held Test Kit S Primary Injection Test daptor S Full-function Test Kit S Seven-pin Test Cable (for connection between test kit and trip unit)e S Two-pin Test Cable (for connection between test kit and trip unit)f S Vac Filtered Power Cordg S Vac Filtered Power Cordg S Trip Unit Battery for Trip Indicator Lights S Power supply with: Vdc input /60 Vdc input Vdc input Vac input New! Vac input Vac input Micrologic Trip Unit Cover, clear S Micrologic P/H Trip Unit Cover, opaque gray S Trip Unit Seal (6 pieces) for compliance with NEC 240.6(c) MICROTUSEL pin Trip Unit Connector for NT/NW Masterpact Circuit Breakers S pin Trip Unit Connector for P- and R-Frame Circuit Breakers S33100i Battery Back-up (12 Hours) e Used for testing Micrologic trip units. Included in the price of the Handheld/Full-function Test Kits. Kit for replacement only. f Used for testing STR trip units. Included in the price of the Handheld/Full-function Test Kits. Kit for replacement only. g Included in the price of the Full-function Test Kit. Kit for replacement only. h DE2F Discount. i DE2 Discount. Table.109: Sensor Plugs for P- and R-Frame Circuit Breakersj Circuit Breaker Description Factory-Installed Suffix Original Circuit Sensor Plug Breaker mperage Range Field-Installable Sensor Plug Catalog No. k S S UL P-Frame S S S S S S IEC P-Frame S S S S S S UL R-Frame S S S S S S IEC R-Frame S S S j For use only with circuit breakers with date codes later than k DE2F Discount. Table.110: Trip Unit Field-Installable ccessories Description Factory-Installed Suffix dder Unit Mount I-Line P-Frame Motor Operated Field-Installable Kit Drawout With Rotary Handle Unit Mount Circuit Breaker Communication Module (BCM) (Modbus) E S64205 S64205 S6420 S64206 S64205 S64205 S Two Programmable Contacts Module (M2C) V S6423 S6423 S6423 S6423 S6423 S6423 S Six Programmable Contacts Module (M6C) W S64204 S64204 S64204 S64202 S64204 S64201 S External Voltage Sensing (EVS) YV S64203 S64203 S64210 S64209 S64210 S64208 S R-Frame I-Line Schneider Electric DE2 DE2F Discount This document provided by Barr-Thorp Electric Co., Inc

45 Masterpact NT Masterpact Universal Power Circuit Breakers Masterpact NW Table.111: Masterpact NW Circuit Breaker s Interrupting Current (k RMS) 50/60 Hz Masterpact NT/NW Circuit Breakers Class 613 / Refer to Catalog 0613CT0001 The Masterpact universal power circuit breaker offers a family of circuit protection products meeting the most common world standards, NSI, UL and IEC. The basic design platform for each is common. The final result is UL, NSI and IEC circuit breakers with the same basic external dimensions, features and accessories. Full-Featured Performance Complete product offering up to 200 k IR without fuses Circuit breakers tested to show arc flash hazard risk category as referenced by NFP0E 800 to 6000 frames, fixed and draw-out Rated for C voltage systems through 600 V (635 V NSI) Short-time withstand ratings up to 100 k Cradle position indicator: connected, test and disconnected Simple, visual contact wear indicators Full complement of field-installable accessories common to all standards Four interchangeable Micrologic trip units to choose from vailable PowerLogic based power metering and monitoring capabilities vailable protective relay functions as defined by NSI C3.2 and C3.90 The following charts show the Masterpact NW and NT ratings for NSI and UL 489. See Pricing Guide 0613PL0001 and Catalog 0613CT0001. Standard NSI C3 Certified/UL 1066 Listed UL 489 Listed Frame /4000 f 4000/ /1200/1600/ / /5000/6000 Interrupting Code N1 H1 H2 H3 L1g L1Fg H1 H2 H3 L1g L1Fg H1 H2 H3 L1g H2 H3 L1g N H Lg LFg H Lg H Lg Short-time Withstand Current (k RMS) Built-in Instantaneous Override (k RMS ±10%) Close and latch rating (k RMS) Tested to show the arc flash hazard risk category as referenced by NFP0E Breaking time Closing time Sensor 240 Vac Vac Vac a 65a 30ab c c c 85 35c ab d Yes Yes Yes ms with no intentional delay (9 ms for L1, L1F, L and LF) 0 ms Endurance (C/O Cycles) Mechanical 12,500 10,000 10,000 5k 5,000 12,500e 10,000 5,000 With No Maintenance Electrical ,000 1,000 1k 1, e 1,000 1,000 a 24 k RMS for 800 circuit breaker frame with 100 or 250 sensor. b 65 k RMS for c None except 24 k RMS for 800 circuit breaker frame with 100 or 250 sensor. d 40 k RMS for e The endurance rating for 2000, N/H/L/LF is 10,000 for mechanical and 1000 for electrical. f 4000 standard with circuit breaker is not available in L1 interrupting rating code or drawout construction (fixed mounting only). g Drawout mounted only. Table.112: Masterpact NT Circuit Breaker s Interrupting Current (k RMS) 50/60 Hz Standard NSI C3 Certified/UL 1066 Listed UL 489 Listed Frame h Interrupting Code N1 N H L1 L LFi N H L1 L LFi N H L1 L 240 Vac Vac Vac N/ N/ Short-time Withstand Current (k RMS) Built-in Instantaneous Override (k RMS ±10%) Close and latch rating (k RMS) Tested to show the arc flash hazard risk category as referenced by NFP0E Yes Yes Breaking time ms with no intentional delay ms with no intentional delay (9 ms for L and LF) Closing time < 50 ms Sensor Endurance (C/O Cycles) Mechanical 12,500 12,500 12,500 12,500 With No Maintenance Electrical h Fixed-mounted only. i Drawout mounted only. NWMPRRT Table.113: Masterpact NW Circuit Breaker Remote Racking Description Masterpact NW Remote Racking Devicea NWMPRRT Mounting Bracket Kit for NW Remote Racking (contains 10 mounting brackets) S Control Unit for NW Remote Rackingb S ft Control Cable for NW Remote Rackingb S Drive Shaft for NW Remote Rackingb S a Unit comes with 10 mounting brackets included. b For replacement only Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

46 Ground-Fault Protection GC-200 Relay GC DSP Display T3B Toroid Sensor GT912 Rectangular Sensor GC-200 Ground-Fault Relay System Class 931, 940, GC-200 Ground-Fault Relay System The GC-200 Ground-fault relay system protects a grounded distribution system from lowlevel arcing ground faults. The system includes the GC-200 relay, a sensor (current transformer), and optional GC DSP display and is used with a bolted pressure switch or circuit breaker to open a circuit upon detection of a ground fault. (Replaces GC-100 relay.) GC-200 Relay Features Five models with sensitivities suitable for main, feeder, or branch circuits Ten adjustable pickup settings for each model Small, non-metallic enclosure mounts on DIN rail 10 and 5 output contacts for trip and alarm Zone-selective interlocking (ZSI) to optimize coordinated systems I 2 t inverse time characteristics GC DSP Display (Optional) Real-time display of ground-fault values lso recalls ground-fault at last trip or at maximum since reset llows remote testing or resetting of the relay LCD back-lit display Surface mounts over panel meter cutout Fine adjust pickup settings (D and E versions only) Sensors Zero sequence sensing current transformers for all phases and neutral Several sizes of toroids and rectangular CTs Many are split-core or open frame for ease of installation Table.114: Ground-Fault Relay Description Specifications GC m 300 m GC200B 300 m GC200C Ground-fault relay GC200D GC200E GCDSP Display module GC4 4 feet GC12a Display cable 12 feet GC30 30 feet a One GC12 twelve foot cable is included with GCDSP display modules. Table.115: GC-200 Relay Settings djustable Pickup Settings (in s) GC GC200B GC200C GC200D GC200E Table.116: GC-200 Sensors Relay Cat. No. GC200 GC200B GC200C GC200D GC200E Sensor Type CT Ratio Window Dimensions in mm T2B 1.85 dia. 48 dia Toroid 00:1 T3B 2.5 dia. 0 dia T2 Toroid 1.85 dia. 48 dia T3 Toroid 2.5 dia. 0 dia T6 Toroid 5.5 dia. 146 dia T6S Toroid, split-core 5.5 dia. 146 dia :1 T9 Toroid 8.5 dia. 222 dia R13.5 x x R41 Rectangular 4.25 x x R826 8 x x ll "" type sensors above, plus: RZ : x x RZ :1 4.5 x x Rectangular, Open Frame RZ :1 4.5 x x RZ :1 4.5 x x RZ : x x RZ1021 Rectangular, Open Frame 1000: x x RZ : x x GT :1 5.5 x x GT918 Rectangular, Open Frame 600:1 5.5 x x GT :1 5.5 x x GT :1 8.5 x x GT1224 Rectangular, Open Frame 600:1 8.5 x x GT :1 8.5 x x GT :1 9.5 x x Rectangular, Open Frame GT :1 9.5 x x GT1530 Rectangular, Open Frame 600: x x Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

47 RH99M P50 Ground-Fault Protection RH99P New! Vigirex TM Ground-Fault Relay System Class 931, 840, 960 Vigirex Ground-Fault Relay System The Vigirex ground-fault relays, with associated sensors (current transformers), measure the residual current in an electrical installation to detect levels which may be damaging. When used for protection, they cause an associated circuit breaker or switch to interrupt the supply of power to the protected system. They may also be used for monitoring only, with output to an alarm. The product line includes fixed sensitivities from 30 m to 1 and adjustable sensitivities up to 30. The Vigirex relays may be easily mounted on DIN rail or may be panel mounted in a meter cutout. Sensors for conductors range from a little more than an inch diameter toroids, to large rectangular sensors measuring 6 x 18 inches. The compact size of the relay and its sensor make it ideal for protection of OEM equipment as well as branch circuits. Table.11: Vigirex Ground-Fault Relays (UL 1053 Listed) Model Delay Reset Control Voltage Sensitivity DIN Rail Mounted RH10M Instantaneous Manual RH21M RH99M Panel Mounted Instantaneous or 60 msec (2 settings) djustable (9 settings): 0, 0.06, 0.15, 0.23, 0.31, 0.5, 0.8, 1.0, 4.5 sec Manual Manual utomatic RH10P Instantaneous Manual RH21P RH99P Instantaneous or 60 msec (2 settings) djustable (9 settings): 0, 0.06, 0.15, 0.23, 0.31, 0.5, 0.8, 1.0, 4.5 sec Manual Manual utomatic Vac/12 48 Vdc Vac Vac 30 m m m m m m m m m m m m Vac/12 48 Vdc Vac 30 ma or 300 m Vac (2 settings) Vac/12 48 Vdc 5630TD Vac Vac Vac/12 48 Vdc Vac djustable, (9 settings): 0.03a, 0.1, 0.3, 0.5, 1, 3, 5, 10, TD 5633TD 56390TD 56392TD Vac 56393TD Vac/12 48 Vdc Vac Vac 30 m m m m mp m m m m mp m m m m Vac/12 48 Vdc Vac 30 ma or 300 m Vac (2 settings) Vac/12 48 Vdc 5640TD Vac 5642TD Vac djustable 5643TD (9 settings): Vac/12 48 Vdc 0.03a, 0.1, 0.3, 0.5, 1, 56490TD Vac 3, 5, 10, TD Vac 56493TD a 30 m is instantaneous only, except for RH99M and RH99P models. Their suffix TD indicates time delay at 30 m. For models with no time delay (IEC compliant) consult catalog 092CT0401. S200 Table.118: Sensors for Vigirex Ground-Fault Relays Sensors Closed Toroids, Type Vigirex Sensor Iron Rings (Optional) Split toroids, Type O Rectangular Sensors Type Maximum Currentc b PO and GO are not UL recognized c Use as a guideline for sizing wire through sensor. Inside Diameter in. mm T P I M S G T P I M POb GOb x x x x x x Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

48 Ground-Fault Protection Equipment dd-on Ground-Fault and Earth-Leakage Modules Class 931, 940, GFM250 Optional GFM25CT Micrologic dd-on Ground-Fault Module (GFM) The Micrologic ground-fault module (GFM) is a UL Listed circuit breaker accessory for equipment protection. It is a combination ground-fault relay and ground-fault sensing device. Micrologic dd-on Ground-fault Module Features: shunt trip may be field-installed in the HD, HG, HJ, HL, JD, JG, JJ and JL circuit breakers. Shunt trip S29382 (12 Vdc) for circuit breaker may be factory- installed (suffix SN) or field-installed djustable ground-fault pickup levels djustable ground-fault time delays Integral ground fault push-to-test feature and ground-fault indicator ll GFMs are supplied for I-Line mounting, easily convertible to unit mount by removing the I-Line brackets Optional neutral current transformer for 3-phase 4-wire applications. Refer to instructions for proper installation Zone-selective interlocking capability is standard with upstream Micrologic trip system circuit breakers. The GFM can also be zone interlocked with the GC ground-fault system by using a restraint interface module.see Supplementary Digest. 120 Vac control power is required for integral test feature. Meets NEC (c) NOTE: Ground-fault modules cannot be used for alarming only. Table.119: Module/Enclosure Selection Charta Companion Circuit Breaker Prefix b I-Line Switchboard a t 250, the GFM250JD can be used with 80% rated circuit breakers only. b See Supplemental Digest for additional GFMs. Ground-fault Pickup djustment Range GFM HD, HG, HJ, HL GFM150HD L JD, JG, JJ, JL GFM250JD L ccessories H & J GFM25CT Optional Neutral Current Transformer (required for 4-wire loads) Figure.1: New! I-Line J-Frame with ELM installed Earth Leakage Module (ELM) for PowerPact H- and J-Frame MCCBs The Earth Leakage Module (ELM) is an add-on module which, when connected to a PowerPact H- or J-frame MCCB, provides low-level ground-fault sensing and ground-fault relay functions. Because these ELMs are highly sensitive (30 m to 3 ), they provide much greater protection than GFMs (20 mps to 200 mps sensitivity). The ELMs provide greater protection of control circuits and other sensitive equipment. The associated circuit breaker must have a 48 Vdc shunt trip), which may be field-installed (kit S29392) or factory-installed (suffix SP) in the H- or J-Frame circuit breaker. dd-on Earth Leakage Module (ELM) Features: djustable ground-fault pickup levels as low as 30 m djustable ground-fault time delays from instantaneous to 500 msec (Time delay can be applied to the 30 m setting) Integral ground fault push-to-test feature Ground-fault indicator (LED for local status; contacts for remote indication) ll ELMs are supplied for I-Line mounting and are easily convertible to unit-mount by removing the I-Line brackets Three poles; 240 to 600 Vac maximum: 3-wire applications only (no neutral) Line-power obtained through internal bus to provide power for electronics, shunt trip, and integral test feature. shunt trip is required in the circuit breaker; it may be field-installed or factory-installed in the PowerPact H and J circuit breakers. UL 1053 Ground-fault Sensing and Relaying Equipment Table.120: ELM Selection Chartc Companion Circuit Breakerd Prefix Size Enclosure Space Required I-Line Switchboard Pick-Up djustment Range Catalog Number HD, HG, HJ, HL L 30 m 3 ELM150HD JD, JG, JJ, JL L 30 m 3 ELM250JD c t 250, the ELM250JD can be used with 80% rated circuit breakers only. d For Factory Installation of ELM Module: For termination designation (3rd letter of catalog number) use ONLY M. dd factory installed 48 Vdc shunt trip (suffix SP) to breaker plus suffix VL or VM. SP $1. adder. Use VL for H frame $436. adder. Use VM for J frame $4886. adder. Plus the List Price of the H or J breaker Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

49 FL 1P FL/FHL 2P FL/FHL 3P Molded Case Circuit Breakers Thermal-magnetic molded case circuit breakers shown on pages -49 through -51 are permanent trip UL Listed, CS Certified, IEC rated, and also meet the requirements Table.121: F-Frame100, Thermal-Magnetic, 240 Vac, Standard Interrupting Fixed C Magnetic Trip F-Frame Thermal-Magnetic Circuit Breakers Class 650 of Federal Specification W C 35B/GEN as indicated on pages -4 through -. For I-Line molded case circuit breakers, see listings on pages 9-23 through P 2 P 3 P 120 Vac 240 Vac 240 Vac Hold Trip FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL Table.122: F-Frame100, Thermal-Magnetic, 480 Vac, Standard Interrupting Fixed C Magnetic Trip 1P 2P 3P 2 Vac, 125 Vdc 480 Vac, 250 Vdc 480 Vac, 250 Vdc Hold Trip FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL Table.123: F-Frame100, Thermal-Magnetic, 600 Vac Fixed C Magnetic Trip 1P 2P 3 P High Interrupting 2 Vac, 125 Vdc Standard Interrupting 600 Vac. 250 Vdc High Interrupting 600 Vac. 250 Vdc Current Limiting 600 Vac. 250 Vdc Standard Interrupting 600 Vac. 250 Vdc High Interrupting 600 Vac. 250 Vdc Current Limiting 600 Vac. 250 Vdc Hold Trip FHL FL FHL FL FHL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL FHL FL FHL FIL FL FHL FIL L50F L100F Table.124: Mechanical Lug Kit Information Circuit Breaker pplication Standard Optional Terminal Wire Range (WG) L50F 14 4 Cu or 12 4 l L100F 14 1/0 Cu or 12 1/0 l Terminal Wire Range (WG) L50F 14 4 Cu or 12 4 l L100F 14 1/0 Cu or 12 1/0 l Terminal Wire Range (WG) L50F 14 4 Cu or 12 4 l L100F 14 1/0 Cu or 12 1/0 l F, FH, FI F, FH, FI (1) 14 4 WG Cu or (1) 12 4 WG l L50F F, FH, FI F, FH, FI (1) 14 1/0 WG Cu or (1) 12 1/0 WG l L100F F, FH (1) 12 3 WG Cu L100TFa F 150 (only) (1) 2 3/0 WG Cu or l L150F F, FH, FI (1) 14 1 WG Cu CU100F F, FH (1) 12 3 WG Cu CU100TFa a For use in the OFF end only, when the OFF end is the load end. Table.125: F-Frame Interrupting s (Number of Wires Per Lug) Wire Range Lugs Per Kit FL FHL FIL 240 Vac 480 Vac 600 Vac 240 Vac 10 k 18 k (1P), 25 k (2P, 3P) 25 k 25 k (1P) 65 k(2p, 3P) 200 k 480 Vac 18 k 18 k 25 k(2p, 3P) 200 k 600 Vac 14 k 18 k(2p, 3P) 100 k Per Kit Termination Option Termination Letter F = No Lugs L = Lugs both ends P with MT Suffix = Lugs ON end P = Lugs OFF end For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number. F L Termination Letter NOTE: Consider using PowerPact circuit breakers for situations requiring circuit breaker accessories. ccessories Supplemental Digest Compression and Power Distribution Connector Lugs. Supplemental Digest Dimensions Page -54 Enclosures Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

50 Molded Case Circuit Breakers K- and Q4-Frame Thermal-Magnetic Circuit Breakers Class 655, 825, KL/KHL 2P and 3P KIL36250 Table.126: K-Frame250, Current-Limiting Thermal-Magnetic CIrcuit Breakers, 600 Vac 2P, 600 Vac, 250 Vdc djustable C Magnetic Trip Current Limiting Low High KIL KIL KIL KIL KIL KIL KIL P, 600 Vac, 250 Vdc KIL KIL KIL KIL KIL KIL KIL Terminal Wire Range L250K (1) 4 WG 350 kcmil l L250KI (1) 1/0 WG 350 kcmil l L250K (1) 4 WG 350 kcmil l L250KI (1) 1/0 WG 350 kcmil l Table.12: Q4-Frame400, Thermal-Magnetic Circuit Breakers, 240 Vac 2P, 240 Vac 3P, 240 Vac djustable C Magnetic Trip Standard Interrupting Low High Q4L Q4L Q4L Q4L Q4L Q4L Q4L Q4L Terminal Wire Range (WG/kcmil) L400L (1) 1 WG 600 kcmil l or (2) 1 WG 250 kcmil l L400L (1) 1 WG 600 kcmil l or (2) 1 WG 250 kcmil l L250KI L250K Q4L 2P and 3P L400L Table.128: Mechanical Lug Kit Information Standard Circuit Breaker pplication Optional (Number of Wires Per Lug) Wire Range NOTE: Consider using PowerPact circuit breakers for situations requiring circuit breaker accessories. Lugs Per Kit Per Kit KI (1) 4 WG 350 kcmil Cu or l L250K KI KI (1) 1/0 WG 350 kcmil Cu or l L250KI Q (1) 1 WG 600 kcmil Cu or l or (2) 1 WG 250 kcmil Cu or l L400L KI (1) 4 WG 250 kcmil Cu CU250K Q (1) 1 WG 600 kcmil Cu (2) 1 WG 250 kcmil Cu CU400L Table.129: Interrupting s KL KHL KIL Q4 240 Vac 42 k 65 k 200 k 25 k 480 Vac 25 k 35 k 200 k 600 Vac 22 k 25 k 100 k ccessories Supplemental Digest Compression and Power Distribution Connector Lugs. Supplemental Digest Dimensions Page -54 Enclosures Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

51 Molded Case Circuit Breakers L-Frame Thermal-Magnetic Circuit Breakers Class 600, 665, 36, 830 LL/LHL 2P and 3P Table.130: L-Frame400, Thermal-Magnetic Circuit Breakers, 600 Vac 2P, 600 Vac, 250 Vdc P, 600 Vac, 250 Vdc djustable C Magnetic Trip Standard Interrupting High Interrupting Terminal Wire Range Low High LL26125 LL26150 LL2615 LL26200 LL26225 LL26250 LL26300 LL26350 LL26400 LL36125 LL36150 LL3615 LL36200 LL36225 LL36250 LL36300 LL36350 LL LHL26125 LHL26150 LHL2615 LHL26200 LHL26225 LHL26250 LHL26300 LHL26350 LHL26400 LHL36125 LHL36150 LHL3615 LHL36200 LHL36225 LHL36250 LHL36300 LHL36350 LHL L400L (1) 1 WG 600 kcmil l or (2) 1 WG 250 kcmil l L400L (1) 1 WG 600 kcmil l or (2) 1 WG 250 kcmil l LIL P and 3P Table.131: L-Frame600, Extra-High Interrupting and Current-Limiting Circuit Breakers, 600 Vacb 2P, 600 Vac P, 600 Vac djustable C Magnetic Trip Extra-High Interrupting Current Limiting Terminal Wire Range Low High LCL26300 LCL26350 LCL26400 LCL26450 LCL26500 LCL26600 LCL36300 LCL36350 LCL36400 LCL36450 LCL36500 LCL LIL26300 LIL26350 LIL26400 LIL26450 LIL26500 LIL26600 LIL36300 LIL36350 LIL36400 LIL36450 LIL36500 LIL36600 b Type LC, LI, LX, LXI, and LE circuit breakers are NOT recommended for use on single motor branch circuits. NOTE: For L Mission Critical circuit breakers, see Table L600LI (2) 4/0 WG 500 kcmil l L600LI (2) 4/0 WG 500 kcmil l L400L L400LH L600LI5 Table.132: Mechanical Lug Kit Information Standard Circuit Breaker pplication Optional (Number of Wires Per Lug) Wire Range NOTE: Consider using PowerPact circuit breakers for situations requiring circuit breaker accessories. Lugs Per Kit Per Kit L, LH (1) 1 WG 600 kcmil l or Cu or (2) 1 WG 250 kcmil l or Cu L400L L, LH (1) kcmil l or Cu L400LH LE, LX, LXI LC, LI, LE, LX, LXI (2) 1 WG 350 kcmil l or Cu L600LI LI, LE, LX, LXI, LC LE, LX, LXI (2) 4/0 WG 500 kcmil l or Cu L600LI LI, LE, LX, LXI, LC (1) kcmil l or Cu L600LI L, LH (1) 1 WG 600 kcmil Cu or (2) 1 WG 250 kcmil Cu CU400L LI, LE, LX, LXI, LC (2) 1 WG 350 kcmil Cu CU600LI LI, LE, LX, LXI, LC (2) 4/0 WG 500 kcmil Cu CU600LI LI, LE, LX, LXI, LC (1) kcmil Cu CU600LI Table.133: Interrupting Table LL LHL LCL LIL 240 Vac 42 k 65 k 100 k 200 k 480 Vac 30 k 35 k 65 k 200 k 600 Vac 22 k 25 k 35 k 100 k ccessories Supplemental Digest Compression and Power Distribution Connector Lugs. Supplemental Digest Dimensions Page -54 Enclosures Page Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

52 Molded Case Circuit Breakers L-Frame Electronic Trip Circuit Breakers Micrologic Series B Trip System Standard-Function Features: 80% rated True RMS sensing Interchangeable rating plugs LSI, LS(I)G, trip configurations Short-time delay = I 2 t IN and ground-fault delay = I 2 t OUT Integral ground-fault testing LED long-time pickup indication Thermal & magnetic backup protection Long-time & ground-fault memory Optional local trip indicatorsoverload, short circuit, ground-fault Optional local ammeter/trip indicator Universal test set available Optional I-Line mounting (LX, LXI) Optional neutral current transformer for 4-wire systems Table.134: L-Frame600, Micrologic Series B Trip System 3P, 600 Vc Circuit Breakers with Micrologic Standard-Function Trip Systems (LXL, LXIL) Circuit Breakers with Micrologic Full-Function Trip Systems (LEL) Sensor Size Trip Function Standard Function NOTE: Consider using PowerPact circuit breakers for situations requiring circuit breaker accessories a Full-Function Features: 100% rated (600 sensor LE/LEL) circuit breakers are 80% rated) True RMS sensing Interchangeable rating plugs PowerLogic compatible LI, LIG, LS(I), LS(I)G (instantaneous OFF) configurations Short-time delay = I 2 t IN & I 2 t OUT and ground-fault delay = I 2 t IN & I 2 t OUT Short-time withstand rating Integral ground-fault testing Optional ground-fault alarm (no trip) (Requires CIM3F with PowerLogic or see Bulletin 0502DB0001.) LED long-time pickup indication Zone-selective interlocking (short-time & ground-fault) Long-time & ground-fault memory Local Trip Indicatorsoverload, short circuit, ground-fault Local ammeter/trip indicator Universal test set available Optional I-Line mounting (LE) Optional neutral current transformer for 4-wire systems Standard Function Current Limiting 100% Rated Full Functionb LI LEL36600LI LSI LIG LXL LXIL LEL36600LS LEL36600LIG RP100 LSIG LXL36600G LXIL36600G LEL36600LSG a 600 sensor is 80% rated b Substitute () in place of (G) for ground-fault alarm (pickup indication only). Requires CIM3F and Powerlogic, or see Data Bulletin 0502DB0001. No instantaneous OFF position for LI or LIG trip function type circuit breakers. c Type LC, LI, LX, LXI, and LE circuit breakers are NOT recommended for use on single motor branch circuits. Optional Lugs Page -51 Dimensions Page -54 LXL LEL LXIL Enclosures Page -56 Table.135: Interrupting s 240 V 100 k 100 k 200 k 480 V 65 k 65 k 200 k 600 V 35 k 35 k 100 k Installed Plug LI LEL36100LI LSI LXL LXIL LEL36100LS LIG LEL36100LIG RP040 LSIG LXL36100G LXIL36100G LEL36100LSG LI LEL36125LI LSI LXL LXIL LEL36125LS LIG LEL36125LIG RP050 LSIG LXL36125G LXIL36125G LEL36125LSG LI LEL36150LI LSI LIG LXL LXIL LEL36150LS LEL36150LIG RP060 LSIG LXL36150G LXIL36150G LEL36150LSG LI LEL3615LI LSI LIG LXL LXIL LEL3615LS LEL3615LIG RP00 LSIG LXL3615G LXIL3615G LEL3615LSG LI LEL36200LI LSI LIG LXL LXIL LEL36200LS LEL36200LIG RP080 LSIG LXL36200G LXIL36200G LEL36200LSG LI LEL36225LI LSI LXL LXIL LEL36225LS LIG LEL36225LIG RP090 LSIG LXL36225G LXIL36225G LEL36225LSG LI LEL36250LI LSI LIG LXL LXIL LEL36250LS LEL36250LIG RP100 LSIG LXL36250G LXIL36250G LEL36250LSG LI LEL36300LI LSI LXL LXIL LEL36300LS LIG LEL36300LIG RP05 LSIG LXL36300G LXIL36300G LEL36300LSG LI LEL36350LI LSI LXL LXIL LEL36350LS LIG LEL36350LIG RP088 LSIG LXL36350G LXIL36350G LEL36350LSG LI LEL36400LI LSI LIG LXL LXIL LEL36400LS LEL36400LIG RP100 LSIG LXL36400G LXIL36400G LEL36400LSG LI LEL36450LI LSI LIG LXL LXIL LEL36450LS LEL36450LIG RP05 LSIG LXL36450G LXIL36450G LEL36450LSG LI LEL36500LI LSI LIG LXL LXIL LEL36500LS LEL36500LIG RP083 LSIG LXL36500G LXIL36500G LEL36500LSG Terminal Wire Range L600LI35 (2) 1 WG 350 kcmil l L600LI5 (2) 4/0 WG 500 kcmil l Schneider Electric DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

53 Molded Case Circuit Breaker Table.136: Neutral Current Transformers Micrologic Series B Trip Unit ccessories Sensor Where Used LE25CT2 LE4CT2 LE6CT LXL, LEL, LXIL LXL, LEL, LXIL LXL, LEL, LXIL Combination Local Current Meter and Trip Indicator Electronic Trip Unit with Seals Installed to Restrict ccess Table.13: Electronic Trip Indicator and Current Meter Field-installable Kits Device Included With Circuit Breaker Optional Local Trip Indicator Kit LTI LXL, LXIL Local Current Meter Kit/Trip Indicator LM LEL LXL, LXIL Complying with NEC The National Electrical Code, Section 240-6(c) exception allows conductor ampere ratings equal to the selected long-time pick-up setting. The seals below can be used to restrict access to the trip unit once settings are selected. Table.138: Trip Unit Seals Description Package Quantity Trip Unit Seal, Series B TUSEL Non-lead Trip Unit Seal (for Micrologic Trip Unit, Vigirex, etc.) MICROTUSELa a Discount schedule DE2F Table.139: Interchangeable Plug Kits for all Circuit Breakers with Micrologic Series B Trip System Sensor Multiplier Value RP RP RP RP RP RP RP RP RP RP RP RP RP RP Universal Test Set Table.140: Test Equipment for Circuit Breakers with Micrologic Series B Trip Systemsb Description Universal Test Set (includes test module for Full-function and Standard-function LEL, LXL, LXIL) UTS Test Module for Full-function and Standard-function LEL, LXL, LXIL. (For use with existing CBTU1 or UTS3 test set.) CBTMB Replacement ribbon cable and rating plug adapter for CBTMB CBTMBRK Long-time and ground-fault Memory Reset Module (Series B Electronics) MTMB b See the Supplemental Digest for more information Schneider Electric DE2 DE2F Discount This document provided by Barr-Thorp Electric Co., Inc

54 Dimensions and Shipping Weights B B E G Figure 1 E G Figure 6 B B Figure 10 B E Figure 13 Figure 1 B E F B G E G Figure 4 B E B E G Figure B B B G Figure 2 E Figure 14 B B E Figure 11 Figure 18 E F B B E G Figure 5 G Figure 8 Figure 15 Figure 19 B C/L B B E G Figure 3 D C D C QO-GFI, QO-PL QO-EPD F QOU, QYU Low E Figure 12 B B E F Figure 16 Figure 20 B G H H C/L Miniature and Molded Case Circuit Breakers D C QO, QOB D C Figure 9 QO-PLPS D C B F QOU High E B E D C D C C60 D C C120 B Table.141: QO, QOU, Multi 9 TM Circuit Breakers Circuit Breaker Prefix QO, QOB QOB-VH 150 QOB-VH QO-PL QO-GFI QO-EPD QOU QYU Low QOU High Multi 9 C60N Poles Fig. No. DimensionsInches B C D E F G a a a b b b c d c d d f QO-PLPS Power Supply a 35 0 is 3.12 in; P and P are 3.50 in. b QO-PL is 4.55 in. c P and P are 4.45 in d P and P are 6.8 in. e in. f is 6.8 in. Table.142: QB, QD, QG, QJ, Q4, F, FI, K, KC, KI, L, LC, LI, LE, LX, LXI, M Circuit Breakers Circuit Breaker Prefix QB, QD, QG, QJ Poles Fig. No. DimensionsInches B C D E F G H g g FL, FHL FIL, KL, KCL, KHL, KIL 2 & Q4L, LL, LHL 2 & LIL, LEL, LXL, LXIL, LCL 2 & ML, MHL 2 & g Dimensions E are 1.59 in at ON end and 0.63 in at OFF end. Table.143: Shipping Weightsh Frame Size pprox. Shipping Weight (Lbs.) Frame Size h ll weights are for 3P circuit breakers unless otherwise noted. pprox. Shipping Weight (Lbs.) FL, FHL 1P 2 KIL 9 FL, FHL 2P 3 LL, LHL 15 FL, FHL 3P 5 LEL, LIL, LXL, LXIL, LCL 25 FIL 8 Q4L 15 QB, QD, QG, QJ 4 ML, MHL 34 KL, KHL E Figure 21 B G E Figure 22 D C E Figure 23 E F E Figure Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

55 Dimensions and Shipping Weights Molded Case Circuit Breakers B B G E Table.144: HD, HG, HJ, HL, JD, JG, JJ, JL, DG, DJ, and DL Circuit Breakers F E F C D Circuit Breaker Prefix Dimensions No. of Fig. No. Poles Inches B C D E F G HD, HG, HJ, HL JD, JG, JJ, JL DG, DJ, DL Figure 25 Figure 26 G B F C D Table.145: ED, EG, EG and GJL Circuit Breakers Circuit Breaker Prefix No. of Poles Fig. No. Dimensions Inches B C D E ED, EG, EJ ED, EG, EJ ED, EG, EJ GJ Table.146: MG, MJ, PG, PJ, PL, RG, RJ and RL Circuit Breakers E Figure 2 G Circuit Breaker Prefix No. of Poles Fig. No. Dimensions Inches B C D E F G MG, MJ (800 and below) 2, PG, PJ, PK, PL ( ) 2, RG, RJ, RL 2, Table.14: Shipping Weightsa C D Figure 28 B F Frame Size pprox. Shipping Weight (Lbs.) Frame Size pprox. Shipping Weight (Lbs.) HD, HG, HJ, HL 2P 4 DG, DJ, DL 14 HD, HG, HJ, HL 3P 5 GJ 3 JD, JG, JJ, JL 5 MG, MJ 34 ED, EG, EJ 1P 2 PG, PJ, PL 32 ED, EG, EJ 2P 3 RG, RJ, RL (Without RLTB) 52 ED, EG, EJ 3P 4 a ll weights are for 3P circuit breakers unless otherwise noted. E E B B E E B Figure 29 Figure 30 Figure 31 B Figure 32 C D E F E G B C D D C Figure 33 G B F D C E Figure Schneider Electric This document provided by Barr-Thorp Electric Co., Inc

56 Circuit Breaker Enclosures F100S F100RB F100DS New! New! New! Enclosures Class Circuit breaker enclosures are UL Listed, CS Certified and are suitable for use as service equipment except as footnoted. The short circuit rating of an enclosed circuit breaker is equal to the rating of the circuit breaker installed, except as footnoted. Circuit breakers are ordered and shipped separately for field installationsee pages -49 through -52. For enclosure accessories and dimensions refer to page -58. See Supplemental Digest Section 3 for NEM and 9 enclosures. Table.148: Circuit Breaker Enclosures Circuit Breaker a Enclosures with NRB or RB suffix have provisions for 3/4 in. through 2-1/2 in. bolt-on hubs in top endwall. Enclosures with R suffix have blank endwalls and require field cut opening. For details and hub catalog numbers see page 3-9. b Not CS Certified. c Suitable for rainproof NEM 3R application by removing drain screw from bottom endwall. d When using a CT in the M800S and R enclosure the unit will no longer accommodate a 200% neutral solution. e Short circuit rating is 100 k IR at 480 Vac maximum. f LEL 100% rated circuit breaker except for 600 sensor. g DE2 Discount. h ccepts MGL or MJL standard rated (80%) breakers. ccepts PGL, PJL or PLL breakers 80% or 100% rated breakers, 800 maximum. i CE certified per IEC , IP20D, PE type TN-C or TN-S j CE certified per IEC , IP24D, PE type TN-C or TN-S k CE certified per IEC , IP56, PE type TN-C or TN-S l Copper wire only. m Maximum short circuit rating is 25 kir, 240 Vac. n Maximum short circuit rating is 18 kir, 480 Vac and 240 Vac. o Order service ground kit PKOGT2 if required. p ccepts standard rated 80% breakers. Not rated at 100%. q Maximum short circuit rating is 25 kir, 600 Vac; 65 kir. r Earth Leakage Module is not compatible with these enclosures. s UL Listed Only t Use 500 Vdc or 250 Vdc rated circuit breakers only. Enclosure Prefix Poles NEM 1 Flush NEM 1 Surface NEM 3Ra FL, FHL, FCL , 2, 3 F100F F100S F100RB QBL, QDL, QGL, QJL Q22200NSbg Q22200NRBbg , 3 Q23225NFbg Q23225NSbg Q23225NRBbg HDL, HGL, HJL, HLL , 3 JDL, JGL, JJL, JLL , 3 J250Fpqr J250Spqr J250Rpqr HDL HD100Slmopqr JDL JD250Slonpqr LL, LHL, Q4L , 3 L400F L400S L400R LL L400LSlo MGL, MJL, PGL, PJL, PKL, PLL , 3 M800Sdi M800Rdj PGL, PJL, PKL, PLLh , 3 P1200Si P1200Rj NEM 4, 4X, 5, 3, 3R Stainless Steel (HubsSee page 3-9) NEM 12/3R, 12K (HubsSee page 3-9) With Knockouts (NEM 12K) Without Knockoutsc (NEM 12/3R, 5) FL, FHL, FCL , 2, 3 F100DS F F100WK HDL, HGL, HJL, HLL , 3 JDL, JGL,J JL, JLL , 3 J250DSpqr J250WKpqr KILe, KCL , 3 IK250DS IK250WK LL, LHL, Q4L , 3 L400DS L400WK LELf, LXL, LXIL LX600WK LCL, LIL , 3 LX600WK MGL, MJL, PGL, PJL, PKL, PLL , 3 M800DSk M800WKk PGL, PJL, PKL, PLLh , 3 P1200WKk Table.149: DC CIrcuit Breaker Enclosures for M and MH DC-Rated Circuit Breakers Prefix...Suffix Circuit Breakert Poles NEM 1 Surface Enclosures Enclosure FL...WB, FHL...WB, KL , 3 K250SWB K250RWB u Catalog number in table is enclosure only. For complete installation, the following must be ordered separately: WB Circuit Breakers (qty. 2, Supplemental Digest), Walking Beam ssembly (Supplemental Digest), Mounting Pan (Supplemental Digest), Neutral (page -56) and Service Ground Kit (page -58). v Enclosure has blank top endwall. w For applications above 200 requiring a neutral, use copper wire only. ML, MHL , 3 M1200S Table.150: Enclosures for Walking Beam Manually Operated Mechanical Interlock Circuit Breakers (UL Listed)u Prefix...Suffix Circuit Breaker NEM 1 Surfacev NEM 3R vw Poles Enclosure Enclosure ccessories Page -58 Dimensions Page -58 Q-frame Circuit Breaker Enclosures Page Schneider Electric DE1 DE2 Discount This document provided by Barr-Thorp Electric Co., Inc

Selection Information 7-2. Motor Circuit Protectors Automatic Switches Vdc Circuit Breakers 7-35

Selection Information 7-2. Motor Circuit Protectors Automatic Switches Vdc Circuit Breakers 7-35 Table of Contents Section Miniature and Molded Case Circuit Breakers H-Frame J-Frame Selection Information -2 QO and QOU Miniature Circuit Breakers -10 QO Miniature Circuit Breakers -10 QO Circuit Breaker

More information

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35 Circuit Breakers Selection Guide Description Page Selection Information -2 QO and QOU Miniature Circuit Breakers -10 H-Frame J-Frame QO Miniature Circuit Breakers QO Circuit Breaker Accessories QO and

More information

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35 Circuit Breakers Selection Guide Description Page Selection Information -2 QO and QOU Miniature Circuit Breakers -10 B-Frame H-Frame QO Miniature Circuit Breakers QO Circuit Breaker Accessories QO and

More information

Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip. Discount Schedule DE2A

Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip. Discount Schedule DE2A OR URRNT INORMTION I I Two-wire SWN New! 2P I Three-wire SWN QO With Shunt Trip K Key Operated QO and Miniature ircuit reakers QO rc-ault ircuit reaker QO arc-fault circuit breakers provide branch feeder

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

1.5 INCH W X 2.91 INCH D X 3 INCH H

1.5 INCH W X 2.91 INCH D X 3 INCH H 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 ax: 936-560-4685 Q0230 QO230 2P-120/240V-30 Square ompany atalog Number Manufacturer escription Weight per unit Product ategory Q0230 Square

More information

Thermal-Magnetic For Mining Applications Class 600

Thermal-Magnetic For Mining Applications Class 600 Square D www.squared.com FOR CURRENT INFORMATION Molded Case Circuit Breakers for Mining s These circuit breakers with the properly selected trip range provide protection for trailing cables in compliance

More information

Quality and Innovation for Global Solutions

Quality and Innovation for Global Solutions Commercial and Industrial Circuit Breakers for OEM Applications Quality and Innovation for Global Solutions Make the most of your energy SM One World Source The Opportunity: The world is opening up to

More information

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards -P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit

More information

For the most up-to-date information

For the most up-to-date information www.square.com or the most up-to-date information Thermal-magnetic Molded ase ircuit reakers, 2 mpere rame lass 5,, 734, 8 IL3 JL 3-pole circuit breaker -frame, Thermal-magnetic ( Vac) mpere Magnetic Trip

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

The UL listed heart of the LynTec Lighting Control and Sound Sequencing Panels

The UL listed heart of the LynTec Lighting Control and Sound Sequencing Panels The UL listed heart of the Lighting Control and Sound Sequencing Panels Handle functions as a normal circuit breaker. When switched off or tripped due to overload, the remote control will not turn on power.

More information

Enhancing Short Circuit Selective Coordination with Low Voltage Circuit Breakers

Enhancing Short Circuit Selective Coordination with Low Voltage Circuit Breakers Data Bulletin 0100DB0403R5/05 05/2005 Cedar Rapids, Iowa, USA Enhancing Short Coordination with Low Voltage s Retain for future use. INTRODUCTION DEFINITIONS ASSUMPTIONS CIRCUIT BREAKER BASICS The purpose

More information

8 PANELBOARDS. Series Ratings For NQOD, NF and I-LINE Panelboards Class 1630, 1670,

8 PANELBOARDS. Series Ratings For NQOD, NF and I-LINE Panelboards Class 1630, 1670, Series s For NQOD, NF and I-LINE Panelboards Class 16, 1670, 110 This page contains UL Tested and Certified series combination ratings for panelboards. These ratings apply to either an integral main located

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,

More information

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac)

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac) MINITUR N MOL S IRUIT RKRS PowerPact ircuit reaker JL 3P ircuit reaker QL 2P 0 250 QL 3P 0 250 Tale.46: mpere - and Q-rame ircuit reakers lass 034, 0500 / Refer to atalogs: 034T0201, 0500T902 PowerPact

More information

Retail Products Catalog

Retail Products Catalog Retail Products Catalog www.schneider-electric.us Table of Contents Overview bout Us...4 Product Definitions Types of Circuit Breakers, Residential Load Centers & other Electrical Devices...6 QO Product

More information

I-Line Circuit Breaker Panelboards Catalog 2110CT9701R02/ Class 2110

I-Line Circuit Breaker Panelboards Catalog 2110CT9701R02/ Class 2110 I-Line ircuit Breaker Panelboards atalog 2110T9701R02/16 2016 lass 2110 ONTENTS Description............................................ Page Product Description.................................... Page

More information

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No.

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No. Square D Breakers American International Marketing P.O. Box 9133 Portland OR 97291-033 Closeout #1279-Square-D-Breakers Square D HOM230CP 30A DP Circuit Breaker (NEW) Square D #HOM230CP 30A DP Circuit

More information

LynTec MRTS-12 and MRTS-24 Modular Rain Tight Sequencers

LynTec MRTS-12 and MRTS-24 Modular Rain Tight Sequencers STRT Press ON switch STRT Press ON switch This sequencer serves: TIMING DIGRM DELY TIME STEP RTE are 1 second if no jumpers are installed. Each Sequencer Step controls two breakers, one upper set of terminals

More information

Thermal-Magnetic Circuit Breakers. Electronic Trip Circuit Breakers. Breaking Capacities 9-7 Circuit Breaker Dimensions 9-8

Thermal-Magnetic Circuit Breakers. Electronic Trip Circuit Breakers. Breaking Capacities 9-7 Circuit Breaker Dimensions 9-8 Table of Contents Section 9 International Circuit Breakers Thermal-Magnetic Circuit Breakers SF and SL Circuit Breakers, IC Rated 415/240 Vac Max. 9-2 lectronic Trip Circuit Breakers P-frame, 3P, Micrologic

More information

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

2015 $22. Digest 177. digestplus-us.schneider-electric.com

2015 $22. Digest 177. digestplus-us.schneider-electric.com 2015 $22 Digest 177 digestplus-us.schneider-electric.com Schneider Electric brands that deliver the solutions you demand. Square D power solutions ready for the future. Square D TM by Schneider Electric

More information

QO and HOMELINE Circuit Breaker Load Centers and Enclosures

QO and HOMELINE Circuit Breaker Load Centers and Enclosures QO and HOMELIE Circuit Breaker Load Centers and Enclosures Class 1130, 1131, and 1170 COTET chneider Electric Brands Description Page QO Circuit Breaker Load Centers Class 1130............................

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers Table of Contents Section 7 Model Motor Control Centers Motor Control Centers Structure and Unit Features 7- Merchandised Units General Information 7- Combination Starters with Motor Circuit Protector

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

Series Rated / Fully Rated Tables. Lighting and Appliance Panelboards. Panelboard Special Features

Series Rated / Fully Rated Tables. Lighting and Appliance Panelboards. Panelboard Special Features Table of Contents Section Panelboards NQ Panelboards Page -5, x Series Rated / Fully Rated Tables NQ -2, -42 NF -3 I-Line -3 Lighting and Appliance Panelboards NQ/NF Pricing Procedure -5 NQ Merchandised

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

PowerPact Circuit Breakers 3-3. PowerPact Automatic Switches 3-6. Molded Case Circuit Breakers 3-7. Circuit Breaker Accessories 3-23

PowerPact Circuit Breakers 3-3. PowerPact Automatic Switches 3-6. Molded Case Circuit Breakers 3-7. Circuit Breaker Accessories 3-23 Table of Contents Section 3 Molded Case s and Enclosures PowerPact s 3-3 PowerPact H- and J-Frame s 3-2 3-3 PowerPact L-Frame s 3-4 PowerPact D-Frame s 3-5 PowerPact Automatic Switches 3-6 PowerPact D-frame

More information

Jefferson Public Works Shop Building 2011

Jefferson Public Works Shop Building 2011 BENTON ELECTRIC, INC. SINCE 1967 CCB#4213 GET CONNECTED VOICE 541.967.1244 EMAIL@BENTONELECTRIC.COM Jefferson Public Works Shop Building 2011 701 N Second Street City of Jefferson, Oregon Electrical Equipment

More information

NQOD Circuit Breaker Panelboards

NQOD Circuit Breaker Panelboards Catalog 2005 Class 1630 CONTENTS Description..............................................Page PPLICTION DT.......................................... 3 TYPICL WIRING DIGRMS.................................

More information

NQOD Circuit Breaker Panelboards

NQOD Circuit Breaker Panelboards NQOD Circuit reaker Panelboards Class 1630 CONTENTS Description Page pplication Data..................................................... 3 Typical Wiring Diagrams..............................................

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

Multistandard offer for OEM applications. Single solution source for business without borders

Multistandard offer for OEM applications. Single solution source for business without borders Multistandard offer for OEM applications Single solution source for business without borders 1 Improving customer satisfaction means producing industrial machines that are compliant to international standards,

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

PowerPact H-, J-, and L-Frame Circuit Breakers

PowerPact H-, J-, and L-Frame Circuit Breakers PowerPact H-, J-, and L-Frame Circuit Breakers Catalog 0611CT1001 R01/13 2013 Class 0611 CONTENTS Description............................................. Page Catalog Numbering...........................................7

More information

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45] Multi 9 System Catalog UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers Figure 46: UL 489/CSA C22.2 No.5 Listed C60 240 Vac Circuit Breaker with Box Lug Terminals Figure 47: UL 489/CSA C22.2 No.5 Listed

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Class 730, 731, 733 / Refer to Catalog: 0730CT9801

Class 730, 731, 733 / Refer to Catalog: 0730CT9801 LA CENTES Q Miniature Circuit s Q Plug-n Circuit s Class 730, 73, 733 / efer to Catalog: 0730CT980 www.schneider-electric.us Square brand Q miniature circuit breakers are plug-on products for use in Q

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Integrated Power Center

Integrated Power Center Class 2735 CONTENTS Schneider Electric Brands Description Page Product Description.................................................. 3 Features and Benefits.................................................

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

TeSys Motor Starter Solutions for the North American Market

TeSys Motor Starter Solutions for the North American Market TeSys Motor Starter Solutions for the North American Market Data Bulletin 8536DB0901 Tesys Motor Starter Solutions 8536DB0901 Table of Contents 11/2009 Table of Contents Introduction... 3 Overview of U.S.

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

PowerPact H-, J-, and L-Frame Circuit Breakers

PowerPact H-, J-, and L-Frame Circuit Breakers PowerPact H-, J-, and L-Frame Circuit Breakers Catalog 0611CT1001 R05/15 2015 Class 0611 CONTENTS Description............................................. Page Catalog Numbering...........................................7

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Molded Case Circuit Breakers LMD 800A Frame Sentron Series Type LMXD6 Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Blue Label Continuous 2-Pole (3 Pole Width) 3-Pole Current Rating

More information

Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy SM

Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy SM Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy M Thinking Outside the quare > Who we are chneider Electric total

More information

Section 11. Obsolescent and Obsolete Circuit Breakers. Table of Contents. Obsolescent and Obsolete Types. Obsolescent Circuit Breakers

Section 11. Obsolescent and Obsolete Circuit Breakers. Table of Contents. Obsolescent and Obsolete Types. Obsolescent Circuit Breakers Table of Contents Section Obsolescent and Obsolete Circuit Obsolescent and Obsolete Types Circuit Breaker Availability -2 Pictorial and Dimensions -4-5 Obsolescent Circuit F-Frame Thermal-Magnetic Circuit

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/16 2015 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

22.000A IR. Catalog Number. Price $

22.000A IR. Catalog Number. Price $ Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1 Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series B Ex9BE3C0 Ex9BHC6 www.noarkus.com NORK Ex9 Series B NORK Miniature Circuit Breakers offer these advantages: highperformance, small size, exemplary

More information

Type MP-T Type MP-HT Type MP-MT

Type MP-T Type MP-HT Type MP-MT CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers SMD 800A Frame Digital Solid State Sentron Sensitrip III Series Selection Type SMD6 Type SHMD6 Current Limiting Type SCMD6 Blue Label Black Label Red Label Catalog Current List SMD69600A 600 SMD69700A

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

VL Circuit Breaker DG 150A frame

VL Circuit Breaker DG 150A frame VL Circuit Breaker DG 150A frame Breaker type Defined by the 3rd character of the catalog number G Global (UL, CSA, IEC, CE, CCC), interchangeable K Global, non-interchangeable W Global, 100% rated, non-interchangeable,

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

Lighting Contactors. 6.1 Open Control. Product Overview...

Lighting Contactors. 6.1 Open Control. Product Overview... Lighting Contactors C30CN Mechanically and Electrically Held.1 Product Overview........................................ C30CN Mechanically and Electrically Held Product Description....................................

More information

Restricted to Schneider Electric Personnel. Class 2700/2705/2741/2742 QED-2. OEM Interiors

Restricted to Schneider Electric Personnel. Class 2700/2705/2741/2742 QED-2. OEM Interiors QED-2 Low Voltage Switchboards Square D Brand OEM Interiors Schneider Electric MDS Low Voltage Switchboards SW-2 Pricing Guide 2700PL9201R09/13 2013 Class 2700/2705/2741/2742 Restricted to Schneider Electric

More information

QED-6 Rear Connected Switchboards

QED-6 Rear Connected Switchboards QED-6 Rear Connected Switchboards with Masterpact NW & NT and PowerPact H-, J- & D-Frame Circuit Breakers Square D QED-6 rear connected low voltage switchboards are proven, reliable and durable. These

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G . NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................

More information

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004 Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Panelboards Ready To Install (RTI)

Panelboards Ready To Install (RTI) Panelboards Ready To Install (RTI) Selection Guide Contents Description Page NQ - 240 Volt Lighting and Distribution Panelboard QO - Plug On Branch Breakers 2-3 QOB - Bolt On Branch Breakers 4 QO/QOB Branch

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information