ROOM CONTROLLER STRA-04 TECHNICAL CATALOGUE AND INSTALLATION

Size: px
Start display at page:

Download "ROOM CONTROLLER STRA-04 TECHNICAL CATALOGUE AND INSTALLATION"

Transcription

1 ROOM CONTROLLER STRA-04 TECHNICAL CATALOGUE AND INSTALLATION

2 2 STRA-04 Room Controller - Technical catalogue and installation STRA-04 ROOM CONTROLLER FOR OPTIVENT DESCRIPTION STRA-04 is a preprogrammed room controller intended to control heating and cooling in after-treatment systems. It is preprogrammed with communication and is intended for use in premises where high comfort and low energy consumption is aimed, e.g. offices, schools, shopping centres, airports, hotels, hospitals and so on. Different parameter values can easily be set in a parameter menu shown on the display, using the buttons on the controller. The parameter value is changed using the INCREASE and DE- CREASE buttons, and the change is confirmed with the Function button. KEY FEATURES Display Setpoint Occupancy Communication CO 2 function SPECIFICATIONS Communication via RS485 (Modbus or EXOline) Easy installation thanks to separate basic plate for cable connections. Four separate operation positions On/Off or 0-10 or 2-10 V control Input for occupancy detector, window contact and CO 2 function. Cabel dimension less than 0.75 mm2 shall not be used for connection of components to room controller STRA. PRODUCT CODE EXAMPLE Room controller for Optivent STRA

3 STRA-04 Room Controller - Technical catalogue and installation 3 CONFIGURATION Control state STRA-04 is preprogrammed for the following control sequences: Heating/cooling Heating/cooling with VAV-control and supply air forced ventilation Heating/cooling through VAV-control The controller is factory set to Heating/Cooling with VAVcontrol and supply air forced ventilation. Changing the preset operating mode is easily done in the parameter menu in the display. Information on how to access the parameter menu and configure the controller, consult either the technical manual or the installation and maintenance folder. STRA-04 can control several VAV-dampers. The number is dependant on the initial electrical consumption of the damper. Contact one of oursales offices for more information. DISPLAY Function button Increase Decrease The display on the controller STRA-04 has the following indications: COMMUNICATION STRA-04 is equipped with Modbus communication as standard. It can act as a stand-alone unit or be connected to a central SCA- DA-system via RS485 (EXOline or Modbus). CONNECTION To keep the unit as compact as possible, the communication input on the STRA-04 is not galvanically separated from the supply voltage. This means that it is vital to be able to distinguish clearly between G and G0, as well as the communication input s A and B. All STRA regulators that share a transformer and communication loop must use the same transformer pole for G (terminal 10) and G0 (terminal 11), respectively. On the communication loop, the A terminal (terminal 42) may only be connected to another A terminal, and the B terminal (terminal 43) to another B terminal. Otherwise there is a high risk of short circuiting, which would ruin the components. USER INSTRUCTION 1. A brief pressure on the function key toggles between forced supply air and normal operation. Forced supply air is indicated by this symbol: 2. A long pressure (over 5 seconds) on the function key shuts the controller off, i.e. it goes into sleep mode. The background lighting on the screen is shut down. 3. A new brief pressure re-starts the controller and it goes initially to forced supply air.

4 4 STRA-04 Room Controller - Technical catalogue and installation APPLICATION EXAMPLES APPLICATION OVERVIEW FOR STRA-04 APPLICATION EXAMPLES FOR STRA-04 Room 2 Room 3 Room 4 ROOM CONTROL 1 Optivent for cooling and radiator for heating EXOline alt. RS485 Modbus SCADA STRA OPTIVENT Transformer STRZ-24 (Required component) Internal temperature sensor VAV/Optivent External temperature sensor STRZ-05 Occupancy detector STRZ-09 Optional accessories Window contact STRZ-38 CO 2 sensor STRZ-38 Transformer STRZ-24-1 Thermal actuator and valve STRZ-70-bb-cc-0-1 RADIATOR ROOM CONTROL 2 Optivent for cooling and radiator for heating. Master/Slave connection ROOM CONTROL 3 Optivent for cooling and radiator for heating. Parallell control. Grey cable from Optivent = Control signal STRA Master OPTIVENT Slave OPTIVENT STRA OPTIVENT OPTIVENT Transformer STRZ-24-1 Thermal actuator and valve STRZ-70-bb-cc-0-1 RADIATOR Transformer STRZ-24-1 Thermal actuator and valve STRZ-70-bb-cc-0-1 RADIATOR ROOM CONTROL 4 Optivent for cooling and radiator for heating. Occupancy control. ROOM CONTROL 5 Optivent for cooling and radiator for heating. Occupancy control and CO 2 control STRA OPTIVENT STRA OPTIVENT CO 2 sensor STRZ Transformer STRZ-24-1 Thermal actuator and valve STRZ-70-bb-cc-0-1 Occupancy detector STRZ-09-1 RADIATOR Transformer STRZ-24-1 Thermal actuator and valve STRZ-70-bb-cc-0-1 Occupancy detector STRZ-09-1 RADIATOR

5 STRA-04 Room Controller - Technical catalogue and installation 5 TECHNICAL DATA Supply voltage Internal consumption V AC, Hz 2.5 VA Ambient temperature 0-50 C Storage temperature C Ambient humidity Protection class Communication Modbus - Bacnet Communication speed Built-in temperature sensor Material casing Weight Max 90% RH IP20 RS485 (EXOline or Modbus) with automatic detection/change-over 8-bit, 1 or 2 stop bits. Odd, even (FS) or no parity bps (not changeable) NTC type, measuring range, 0-50 C, measurement accuracy ±0.5 C at C Polycarbonate, PC 110 g Cabel dimension less than 0.75 mm2 shall not be used for connection of components to room controller STRA INPUTS External room sensor Occupancy detector CO 2 sensor Condensation detector alt. Window contact OUTPUTS Forced ventilation Valve actuator, thermal actuatoror Optivent Valve actuator Thermal actuator Control Exercise Terminal block PT1000 sensor, 0-50 C. A suitable sensor is Fläkt Woods STRZ-05. Closing potential-free contact. A suitable occupancy detector is Fläkt Woods STRZ-09. STRZ CO 2 sensor (0-10V). Window contact STRZ-38 resp. Potential-free contact 24 V AC actuator, max. 0.5 A 2 outputs 0-10 V DC, max. 5 ma 24 V AC, max. 2.0 A Heating or cooling FS = 23 hour intervals Lift-type for max. cable crosssection 2.1 mm 2 DIMENSIONS The product meets requirements for prevailing European EMC standards CENELEC EN and EN and prevailing European LVD standard IEC The product is CE marked.

6 6 STRA-04 Room Controller - Technical catalogue and installation INSTALLATION INSTALLATION INSTRUCTIONS Follow local safety regulations when installing the product. Alternative

7 STRA-04 Room Controller - Technical catalogue and installation 7 WIRING CONNECTION DIAGRAM FOR STRZ-05, STRZ-18, STRZ-09, STRZ-70, OPTIVENT AND WINDOW CONTACT STRZ-38 CONNECTION DIAGRAM FOR STRZ-05, STRZ-18, STRZ-09, STRZ-70, OPTIVENT AND CONDENSATION SENSOR STRZ-16

8 8 STRA-04 Room Controller - Technical catalogue and installation WIRING Terminal Designation Function 10 G Supply voltage 24 V AC 11 G0 Supply voltage 0 V 20 GDO 24 V AC out common for DO. Internally connected to terminal 10, G. 21 G0 0 V common for UO. Internally connected to terminal 11, G ) UO2 23 UO1 24 UO3 Control of heating For 0-10 V DC valve actuator, max. 5 ma (FS). The valve actuator s 0-10 V control signal terminal is connected to terminal 23 and its supply terminals are connected to terminals 10 and 11. Make sure that the reference pole G0 is connected to the correct terminal on the actuator. alternatively For 24 V AC thermal actuator, max. 2.0 A. The thermal actuator is connected between terminals 23 and 20, GDO. Control output cooling For 0-10 V or 2-10 V DC valve actuator, max. 5 ma (FS). The valve actuator s 0-10 or 2-10 V control signal terminal is connected to terminal 22, and its supply terminals are connected to terminals 10 and 11. Make sure that the reference pole G0 is connected to the correct terminal on the actuator. alternatively For 24 V AC thermal actuator, max. 2.0 A. The thermal actuator is connected between terminals 24 and 20, GDO. Control output ventilation For forced ventilation (Bypass). The on/off actuator is connected to terminal 24 and its supply terminals to terminals 10 and Al1 For external room sensor PT1000. Measuring range 0-50 C. Connect sensor between terminal 30 and 41, AGnd. 31 AI2 For 0-10V CO 2 sensor, input signal. 32 DI1 33 DI2/CI Occupancy detector. Potential free contact is connected between terminal 32 and 40, +C. Closed contact indicates occupancy. Also see Occupancy detector section. Fläkt Woods STRZ-16 (FS) condensation detector. Connect the sensor between terminal 33 and 41, AGnd. alternatively Window contact DI). Connect potential free contact between terminal 33 and 40, +C. Closed contact indicates closed window. 40 +C 24 V DC out common for DI and UI (with digital function) 41 AGnd Analogue earth, reference for AI and UI with analogue function) 42 A RS485 communication A 43 B RS485 communication B 1) On version 1.4.x.x.x has UO2 and UO3 switched pin for STRA-04, UO2= Pin 22 and UO3=24. You can with parameter 328 switch back UO2 to pin 24 like in 1.3.x.x.x by set 328 to 0. Version 1.4 is introduced since June 2013.

9 STRA-04 Room Controller - Technical catalogue and installation 9 OPERATION SETPOINT ADJUSTMENT In Occupied mode, the controller operates from a heating setpoint (FS = 22 C), or a cooling setpoint FS = 24 C) that can be changed using the INCREASE and DECREASE buttons. When the IN- CREASE button is pressed, the current setpoint is raised by 0.5 C per press up to the maximum limit (FS = +3 C). When the DE- CREASE button is pressed, the current setpoint is reduced by 0.5 C per press down to the minimum limit (FS = 3 ). Switching between heating and cooling setpoints is done automatically in the controller depending on the heating and cooling requirement. FUNCTION BUTTON If the Function button is pressed briefly (less than 5 seconds) when the controller STRA-04 is in the Preset operating mode (Parameter 45, FS = 3 = Occupied), the controller switches to the Bypass operating mode. If the button is pressed briefly when the controller is in Bypass mode, it will switch to Preset mode. If the Function button is pressed and held for more than 5 seconds, the controller switches to Unoccupied mode, regardless of the current operating mode. If the button is pressed briefly in Unoccupied mode, the controller will return to Bypass (for 60 minutes this is a preset time that can be changed via setting of parameter 12). OPERATING MODES STRA-04 has five operating modes. The Function button can be used to switch between three of them. These operating modes can be set via the parameter menu (parameter 45) in the display. Occupied is the preset operating mode. OFF Operating mode Off means that the controller is inactive (heat and cooling are disconnected). However, the temperature must not drop below the set minimum temperature (parameter 6, FS=8 C). If the room temperature drops below the minimum temperature, the controller will start heating. On the display, the background lighting is not lit, and only OFF is shown. UNOCCUPIED The Unoccupied operating mode is an energy-saving mode. This means that the room controlled by the controller is currently not in use, or is not used for long periods, e.g. during evenings, nights, weekends or by non presence when using occupancy sensor. Both heating and cooling are disconnected within a temperature interval with adjustable min./max. temperatures (Para meters 4 and 5, FS min. = 19 C, max. = 27 C). The background lighting is not lit on the display, but the current room temperature (or setpoint, depending on the configuration) is shown. OFF is shown on the display in this case too. STAND-BY The Stand-by operating mode means that the room is in energy save mode and not currently in use, e.g. during nights, weekends or evenings. This mode is currently not used by default settings from Factory but it can be used instead of unoccupied mode by non presence when using occupancy sensor. The room temperature is controlled around the applicable heating and cooling setpoints with an extended temperature interval (FS = ±3 C). For example, if the heating setpoint is 22 C and the cooling setpoint is 24 C, the controller will allow a room temperature between 19 C and 27 C. In addition, the setpoint values can be locally adjusted ±3 C via a setpoint knob or via the display on the room unit. Display: background lighting is lit (dimmed) and STANDBY, and current room temperature (or setpoint, depending on configuration) is shown on the display. For further information, see Occupancy Control section. OCCUPIED The Occupied operating mode means that the room is in use and is adjusted according to Comfort mode. The controller adjusts the room temperature around a heating setpoint and a cooling setpoint (Parameters 1 and 2, FS heating setpoint = 22 C, cooling setpoint = 24 C). The setpoint values can also be locally adjusted ±3 C via the display on the unit, or via a central command. On the display, the background lighting is lit (dimmed) and the occupancy indicator is lit (see Display Handling section). The current room temperature (or setpoint depending on the configuration) is shown. BYPASS The Bypass operating mode means that the controller adjusts the room temperature in the same way as in the Occupied mode. The output for forced ventilation is also activated (10V cooling output UO2). After a configurable time (Parameter 12, FS = 60 minutes), the controller automatically returns to Preset mode. Bypass is normally activated by pressing the Function button, the occupancy detector (depending on the configuration), or via a central command. This operating mode is useful in conference rooms where many people are present simultaneously for a limited period of time.

10 10 STRA-04 Room Controller - Technical catalogue and installation FUNCTIONS CONTROL OF EXTERNAL DAMPER FOR FORCED VENTILATION There is also the possibility to connect an external damper that when forced ventilation is activated gives a signal to the actuator to open the damper via UO3. Connection STRA G 11 G0 Black (1) Red (2) Actuator LM24 If the Function button is pressed briefly when the controller is in Shutdown or Preset mode, the controller will switch to Bypass mode. If the button is pressed briefly when the controller is in Bypass, the operating mode will switch to Preset. After a configurable time in Bypass (FS=60 minutes), the controller automatically returns to the preset operating mode. For further information on using the Function button in combination with central control, see the Central Control section below. 24 UO3 White (3) OCCUPANCY DETECTOR (Parameter 22 = 1, Forced vent, digital) The background lighting on the display is lit (dimmed). The occupancy detector and the symbol for forced ventilation are lit (see Display Handling section). The current room temperature (or setpoint, depending on the configuration) is shown. ACTIVATION OPERATING MODES PRESET OPERATING MODE Occupied is the preset operating mode. The desired operating mode is configured in the parameter menu on the display (parameter 45). The operating mode in the room controller is changed if the following commands/ events occur: When the Function button is pressed When the occupancy detector is activated/deactivated When the CO value on the 2 analogue input is exceeded If central control is used, e.g. central time control or central booking system. FUNCTION BUTTON Shutdown (Unoccupied) Occupied (Preset operating mode) > 5 s SHUTDOWN (OFF OR UNOCCUPIED) Bypass (Forced ventilation) Button/Timer If the Function button is pressed and held for more than 5 seconds, the controller switches to Shutdown mode, which may be Off or Unoccupied regardless of the current operating mode The activated operating mode, Off or Unoccupied, is configured via the display. The factory configuration is Unoccupied. STRZ-09-1 occupancy detector can be installed for local control of the operating mode with regard to room occupancy. If occupancy control is installed, parameter 45 should be changed to 1 = Unoccupied and parameter 17 changed to 3. This will achieve the function illustrated in the picture above, where the activated occupancy detector shifts to the Occupied operating mode. When the occupancy sensor is deactivated, the controller returns to the Unoccupied operating mode (to save energy). CONTROL STRA-04 can be configured for different control states/ control sequences (Parameter 11, FS = 4 = Heating/Cooling with VAV control and forced supply air function): Heating Heating/Heating Heating/Cooling Heating/Cooling with VAV control and forced supply air Heating/Cooling with VAV control Heating Cooling/Cooling For the control states, UO1 is used for the left control function and UO2 is used for the right control function. If only one control function is active (Heating or Cooling), only UO1 is used. HEATING/COOLING WITH VAV CONTROL AND FORCED AIR SUPPLY Same control function as for Heating/Cooling, except cooling is controlled via a supply air damper (supply air below min. temperature). In the event of forced ventilation, the cooling controller (10V on cooling output UO2) is set to full cooling (full supply air flow) regardless of the controller output signal.

11 STRA-04 Room Controller - Technical catalogue and installation 11 CO 2 CONTROL (P CONTROL) Fläkt Woods STRZ-18-1 is an active CO 2 sensor (0-10V)and is activated in room controller by setting parameter 81 to 5. When the controller exceeds the CO 2 value (parameter 112 FS = 500 ppm), it starts controlling against a fully open damper (UO3). The damper opens fully at Parameter 113 (FS = 1000 ppm). Heating/Cooling (PI) in controlled concurrently with the CO 2 control. If heating is required, the heating signal increases on heating output UO1. WINDOW CONTACT When the window contact has been configured, the regulator is set to normal operation when the window is closed. When the window is open, the controller goes into Off mode, the heating and cooler outputs are set to 0 V and the frost protection function is activated. FROST PROTECTION STRA-04 has built-in frost protection, which is activated when the controller is not in use. The frost protection prevents the temperature from dropping below 8 C. The fan speed and controls automatically return to normal when the frost protection is deactivated. CONTROL THE LIGHT WITH AN OCCUPANCY SENSOR It s possible to control the operation of the light with an occupancy sensor through a relay and its socket (STRZ-73-b). The light will switch off when the room is unoccupied. The socket for wiring is screwless quick connection. Parameter 60 should be changed to 1 when using this function. WIRING DIAGRAM STRA-04 PARAMETER SETTINGS STRA-04 is delivered with a number of factory settings. To achieve the desired function, the controller must be adapted to its application. This is done via the parameter menu in the display. The applications can vary dramatically, and incorrectly set parameters can impairthe controller s and application s function. For this reason, make sure you set the parameters that are critical to your particular application. If in doubt, contact Fläkt Woods TSS Controls. PARAMETER MENU In STRA-04, various parameter values can be set in a parameter menu. This parameter menu is accessed by simultaneously pressing the INCREASE and DECREASE buttons for about 5 seconds until the Service indication lights up in the display. After this, press the INCREASE button twice. Initially, the parameter menu will only show a parameter number (P01, P02, P03 etc.). You can scroll between the parameters by pressing the INCREASE and DECREASE buttons. When the right parameter has been selected, press the Function button. The parameter value will be shown and the parameter number will disappear. The parameter value can now be changed with the INCREASE and DECREASE buttons. When the INCREASE and DECREASE buttons are held pressed down, the value in the display will start scrolling, first slowly and then with increasing speed, in about 3-4 steps with roughly 2-3 seconds between the steps. CONFIRM/REJECT To confirm the changed parameter, press the Function button again. The display will return to showing the parameter number. Before confirming the change, you can retrieve the original value (the value that was displayed before you made the change) by simultaneously pressing the INCREASE and DECREASE buttons. The original value will be shown on the display. RETURN After about 1 minute, or when the INCREASE and DECREASE buttons are pressed simultaneously while you are in the menu, the display will return to normal. The word Exit will appear in the display after the last parameter. By pressing the Function button when Exit appears, you can exit the parameter menu. If you press INCREASE, you reach the first parameter. If you press DECREASE, you reach the last parameter.

12 12 STRA-04 Room Controller - Technical catalogue and installation PARAMETERS The following parameters are modifiable in the parameter menu FS = factory-set value): Parameter number Description Values Unit FS STRA-04 1 Occupied Heating Setpoint N/Aw C 22 2 Occupied Cooling Setpoint N/A C 24 3 Standby Neutral Zone N/A C 3 4 Unoccupied Heatin Setpoint N/A C 19 5 Unoccupied Cooling Setpoint N/A C 27 6 Frost protection Setpoint N/A C 8 7 P-Band N/A C 10 8 I-Time N/A Seconds Cooling Changeover difference temperature (Room and media) N/A C 3 10 Heating Changeover difference emperature (Room and media) N/A C 4 11 Heating/Cooling Functions 0 = Heat, 1 = Heat/Heat, 2 = Heat or Cool via changeover, 3 = Heat/Cool, 4 = Heat/Cool with VAV and forced ventilation, 5 = Heat/Cool with VAV, 6 = Cool, C 4 7 = Cool/Cool, 8 = Heat/Cool with UO3, 9 = Heat/Cool with Change-Over 12 Boost Mode Timer N/A Minutes P.I.R Delay Off N/A Minutes P.I.R Delay On N/A Minutes 0 15 Connected sensor on AI1 0 = internal, 1 = external, 2 = Change over sensor 0 16 UI1 Signal 0 = Disabled, 1 = Change over sensor digital, 2 = Change over sensor analogue 2 17 Connected sensor DI1 Input 0 = Disabled, 1 = Window contact, 3 = P.I.R, 4 = Change over sensor 0 18 Connected sensor DI2 input 0 = Disabled, 1 = Window Contact, 2 = Condensation Sensor, 4 = Change over sensor Function of UO1 Signal 0 = None, 1 = Thermal actuator heat, 2 = None, 3 = Heating actuator 0-10V, 4 = None, 5 = None, 6 = None 1 21 Function of UO2 Signal 0 = None, 1 = None, 2 = Thermal actuator Cool, 3 = None, 4 = Cooling actuator 0-10V, 5 = None, 6 = None 4 22 Function UO3 Signal 0 = None, 1 = Forced Vent Digital, 2 = Forced Vent 3 Step Analog, 3 = None, 4 = Ordinary Analog output, 5 = None, 6 = Control of EC-fan 1 24 UO3 output in manual mode N/A % 0 28 Actuator type for UO3 0 = 0-10 V, 1 = 2-10V, 2 = 10-2V, 3 = 10-0V 29 Heating Modulating Actuator Control 0 = 0-10 V, 1 = 2-10V, 2 = 10-2V, 3 = 10-0V 0 30 Cooling Modulating Actuator Control 0 = 0-10 V, 1 = 2-10V, 2 = 10-2V, 3 = 10-0V 0 31 Heating Thermal Actuator Time N/A Seconds Cooling Thermal Actuator Time N/A Seconds Travelling Time for Increase/Decrease Heating Valve (Not in use) Seconds Travelling Time for Increase/Decrease Cooling Valve (Not in use) Seconds Increase/Decrease NZ (Not in use) % 2 36 Heating Valve Periodic Exercise Interval 0 = inactive Hours Cooling Valve Periodic Exercise Interval 0 = inactive Hours Hysteresis for the heating thermostat function N/A K 2 39 Hysteresis for the cooling thermostat function N/A K 2 40 The minimum heat output in heating mode N/A % 0 41 Fan runs on low speed (Not in use) 0 42 Display View 0 = Actual Temp Value, 1 = Heating Setpoint, 2 = Cooling Setpoint, 3 = Average of Heating/Cooling, 4 = Only Setpoint Displacement, 5 = CO 2, 6 = Heating Setpoint+Setpoint Displacement, 7 = Cooling Setpoint+Setpoint Displacement, 8 = Average of Heating/Cooling Setpoints+Setpoint Displacement, 9 = Calculated Flow in l/s 43 Highest Setpoint Offset Increase N/A C 3 44 Lowest Setpoin Offset Decrease N/A C 3 45 Normal Mode Function 0 = Off, 1 = Unoccupied, 2 = Stand-by, 3 = Occupied 3 46 Energy Saving Mode Function 0 = Off, 1 = Unoccupied 1 47 BMS Operating Mode 0 = Off, 1 = Unoccupied, 2 = Standby, 3 = Occupied, 4 = Not Used, 5 = No Remote control 5 48 Minimum airflow on cooling UO3 in % of 0-10V. Parameter is in use when cooling/heating N/A % 0 mode with VAV is selected 49 Maximum airflow on cooling UO3 in % of 0-10V. Parameter is in use when heating/ cooling mode with VAV is selected N/A % 0

13 STRA-04 Room Controller - Technical catalogue and installation 13 Parameter number Description Values Unit FS STRA Fan Control (Not in use) 0 = internal, 1 = external, 2 = Change over sensor 3 = Both 51 Fan Speed 1 Limit (Not in use) % C Fan Speed 2 Limit (Not in use) % C 3 53 Fan Speed 3 Limit (Not in use) % C Fan Start/Stop Hyst (Not in use) N/A C Fan Speeds N/A C 8 56 External Temperature Sensor Calibration Gain AI1 N/A C 0 57 Sensor Calibration Gain UI1 N/A C 0 58 Internal Temperature Sensor Calibration Gain N/A C 0 59 Filter factor for AI temperature N/A C Normally open/normally closed DI1 0=N/O, 1=N/C 0 61 Normally open/normally closed DI2 0=N/O, 1=N/C 1 62 Normally open/normally closed UI1 0=N/O, 1=N/C 0 63 Heating Manual Override 0=Off, 1=Manual, 2=Auto 2 64 Cooling Manual Override 0=Off, 1=Manual, 2=Auto 2 65 Forced ventilation Manual Override 0=Off, 1=Manual, 2=Auto 2 66 Changeover Manual Override 0=Heating, 1=Cooling, 2=Auto 2 67 Manual Mode Heating Output N/A % 0 68 Manual Mode Cooling Outpu N/A % 0 69 Modbus Address N/A Set by production (same as EXOline ELA) 70 Modbus Parity 0 = None, 1 = Odd, 2 = Even 2 71 Modbus Timeout N/A Milliseconds 3 72 Modbus Response Delay N/A Milliseconds 5 73 Heating output signal 0 = For N/C-actuator, 1 = For N/O-actuator HMI Displacement View 0 = The offset, 1 = The active setpoint + offset, 2 = The heating setpoint + offset, 3 = The cooling setpoint + offset, 4 = Occupied Heating Setpoint + Offset, = Occupied Cooling setpoint + Offset, 6 = Occupied Average + Offset 75 Free Cooling 0=Not Available, 1=Available 0 76 Forced Ventilation control mode 0 = No Action, 1 = Forced on Heat/Cool output at 100%, 2 = Forced on Cool output at 100% 2 77 P.I.R Activated Operation Mode 3 = Occupied, 4 = Bypass 3 78 The Controller PLA Address. Used in EXOline Set by Production The Controller ELA Address. Used in EXOline Set by Production 80 Cool output 0 = For N/C-actuator, 1 = For N/O-actuator 0 81 AI2 Input 0 = Disable, 5 = CO 2, 7 = 0-100%, 8 = Flow calculation, 9 = 0-10V 0 82 Flow at 0 volt on AI2 (Not in use) l/s 83 Flow at 10 volt at AI2 (Not in use) l/s 84 The minimum time the valve is open when the calculation of change over is made N/A Seconds Alarm triggers when temperature falls above N/A C Alarm triggers when temperature raise below N/A C CO 2 Level to Change to Boost Mode N/A PPM CO 2 Level below Boost Mode CO2 Start value N/A to start Boost Mode Timer countdown PPM AI CO 2 Filter N/A CO 2 Sensor PPM for 0V N/A PPM CO 2 Sensor PPM for 10V N/A PPM VAV CO 2 Minimum Limit N/A PPM VAV CO 2 Maximum Limit N/A PPM Port Mode 0 = EXOline/Modbus, 1 = BACnet BACnet address Above 127 = Slave Set by Production (Last 2 Digits of ELA) 116 BACnet device ID low 4 figures N/A Set by Production ( A of PLA & ELA)

14 14 STRA-04 Room Controller - Technical catalogue and installation Parameter number Description Values Unit FS STRA BACnet device ID high 3 figures N/A Set in Production, uses PL of PLA 118 BACnet Max Master N/A Com Speed Com bus speed 0 = 9600, 1 = 19200, 2 = 38400, 3 = (BACnet) 120 Reset com to factory default (Modbus 9K6, 8, N, 1) N/A 121 The lowest output the fan will need to start (Not in use) V 122 The highest speed of the fan (Not in use) V 125 The Model in Regin Range 1943 = STRA-04, 1945 = STRA-14 Read Only Major Version N/A 127 Minor Version N/A 128 Branch Version N/A 129 Revision N/A 300 Voltage x 10 for nozzle 2 % N/A 301 Voltage x 10 for nozzle 3 % N/A 302 Voltage x 10 for nozzle 4 % N/A 303 Voltage x 10 for nozzle 5 % N/A 304 Max air level at 100% cooling N/A 305 Max air level at 100% CO 2 N/A 306 Air level at Off, Unoccupied & Standby N/A N/A 307 Air level at Occupied mode N/A N/A 308 Air level Boost mode (Button only) N/A N/A 309 Free Cooling 0 = Not Available, 1 = Available See Type of STRA 0 = STRA-04, 1 = STRA-14 Set by production 323 The floor the STRA is placed at 9999=Not Used in IPSUM The room the STRA is placed 9999=Not Used in IPSUM High 4 digits of the serial number 326 Mid 4 digits of the serial number 327 Low 4 digits of the serial number 328 Legacy Mode, set to 0 to use the old wiring terminal order 0 = Air on Pin 24, Boost on Pin 22, 1 = Air on Pin 22 Boost on Pin 24 1

15

16 FG_DC_8709GB_STRA-04_TE-IN _R0 Copyright 2018 FläktGroup STRA-04 FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions. PRODUCT FUNCTIONS BY FLÄKTGROUP Air Treatment Air Movement Air Diffusion Air Distribution Air Filtration Air Management & ATD s Air Conditioning & Heating Controls Service» Learn more on or contact one of our offices

STRA-24 for chilled beams

STRA-24 for chilled beams STRA- Installation and commissioning manual STRA- for chilled beams STRA- is the room controller for the pressure independent (Pi) and constant air volume chilled beams. It is possible to set different

More information

ROOM CONTROLLER STRA-24 TECHNICAL CATALOUGE AND INSTALLATION

ROOM CONTROLLER STRA-24 TECHNICAL CATALOUGE AND INSTALLATION ROOM CONTROLLER STRA-24 TECHNICAL CATALOUGE AND INSTALLATION 2 STRA-24 Room Controller for chilled beams - Technical catalouge and installation STRA-24 ROOM CONTROLLER FOR CHILLED BEAMS DESCRIPTION STRA-24

More information

RC-DO. Room controllers with display and manual forced ventilation function

RC-DO. Room controllers with display and manual forced ventilation function revision 10 2017 RC-DO Room controllers with display and manual forced ventilation function RC-DO is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

More information

Modbus Integration Integration for Modbus Functionality for VT8600 Series

Modbus Integration Integration for Modbus Functionality for VT8600 Series Modbus Integration Integration for Modbus Functionality for VT8600 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS

More information

HERZ Electronic room thermostat analog and digital

HERZ Electronic room thermostat analog and digital Dimension in mm 3 F799 11-3 F799 14 HERZ Electronic room thermostat analog and digital Data sheet for F799, Issue 0317 3 F799 15 3 F799 18 Mounting plate Page 1 Technical data 3 F799 11-14 3 F799 15-18

More information

Commissioning manual. - Simplified VAV solution with full potential... Rev. Pascal-Comm RM-ver / RC-ver 1.

Commissioning manual. - Simplified VAV solution with full potential... Rev. Pascal-Comm RM-ver / RC-ver 1. Commissioning manual - Simplified VAV solution with full potential... Rev. -Comm. 22-09-2014-9 RM-ver 1.0-1-08 / RC-ver 1.3-1-10 Table of content Table of content Page Overview system and description 4

More information

CHILLED BEAM IQ STAR WEGA II

CHILLED BEAM IQ STAR WEGA II CHILLED BEAM IQ STAR WEGA II TECHNICAL CATALOGUE 2 IQ Star WEGA II Chilled beam - Technical catalogue CHILLED BEAM IQ STAR WEGA II The WEGA II chilled beam is an active chilled beam system for ventilation,

More information

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection ADAPTTM Extract Extract air diffuser for the WISE system Quick facts Active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring, Plug & Play Communication via Modbus RTU Supplied

More information

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE RECTANGULAR VAV DAPER ERVA TECHNICAL CATALOGUE Rectangular VAV damper ERVA - Technical catalogue 2 KEY FEATURES Variable airflow Constant airflow Real-time airflow measurement with FläktGroup compact controller

More information

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection ADAPTTM Sphere Active communicative, supply air diffuser for the WISE system Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring,

More information

Ventilation in balance

Ventilation in balance Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR MODBUS RTU RS485 BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer. The firmware

More information

Control Solutions Biofloor

Control Solutions Biofloor MCF234 Distributor for Wired Control System COMAP proposes a new control system for heating and cooling underfloor. Consisting of a 6 or 10- channels controller (MCF234), analogic (TAF234) or electronic

More information

SMT-150 Installer Manual

SMT-150 Installer Manual SMT-150 Installer Manual 3 Stage Digital HVAC Controller Version 1.0 Version History January 2019 Version 1 - Original Document Thank you for your purchase of this premier product. Please take the time

More information

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F ADAPTTM Free Active communicative, supply air diffuser for the WISE system, ADAPT F Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple

More information

External grilles USAV, USVN, USSV and SVN TECHNICAL DATA

External grilles USAV, USVN, USSV and SVN TECHNICAL DATA External grilles, U, and TECHNICAL DATA 2 External grilles, U, and U External grilles are used as covering grilles in air supply and exhaust openings. and U are moulded of aluminium. and are deep drawn

More information

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA AIR COMFORT AIR DIFFUSION CHILLED BEAMS IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA 2 Chilled beam IQ Star NOVA II Technical data CHILLED BEAM IQ STAR NOVA II The NOVA II chilled beam is an active chilled

More information

SE8300 Series Installation Guide 24 Vac Low Voltage

SE8300 Series Installation Guide 24 Vac Low Voltage Installation Guide 24 Vac Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 2 Configurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

Room product for Swegon s WISE System for demand-controlled ventilation

Room product for Swegon s WISE System for demand-controlled ventilation Room product for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Integrated temperature sensor Modbus RTU-communication Simple wiring: Plug and Play Available as a package solution for

More information

RDG160TU Commercial Thermostat

RDG160TU Commercial Thermostat Document No. 129-588 RDG160TU Commercial Thermostat Selecting Location Install the thermostat about 4 feet (120 cm) above the floor on an inside wall. Ensure that there is free airflow around the thermostat.

More information

Ventilation in balance

Ventilation in balance Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR BACNET TM /IP. BACNET TM MS/TP BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer.

More information

SMT-AZC INSTALLATION / OPERATION MANUAL

SMT-AZC INSTALLATION / OPERATION MANUAL SMT-AZC INSTALLATION / OPERATION MANUAL 22o OFF VERSION 2.0 www.smarttemp.com INTRODUCTION The SMT-AZC thermostat is designed to work with the Smart Temp 24Volt Zone Dampers TERMINAL DESIGNATIONS The SMT-AZC

More information

Appendix A: Inputs, Outputs, and Parameters

Appendix A: Inputs, Outputs, and Parameters Technical Bulletin Issue Date 11/01/01 TECHNICAL BULLETIN Appendix A: Inputs, Outputs, and Parameters Introduction This appendix describes the inputs, outputs, and parameters used with the Metasys Zoning

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

Metasys Zoning Package Installation

Metasys Zoning Package Installation Technical Bulletin Issue Date August 28, 2002 Metasys Zoning Package Installation Metasys Zoning Package Installation...2 Introduction... 2 Key Concepts... 3 Installation Overview... 3 Metasys Zoning Package

More information

Installation, Service, and Troubleshooting Instructions

Installation, Service, and Troubleshooting Instructions Installation, Service, and Troubleshooting Instructions Page GENERAL........................................ 2 INSTALLATION................................. 2-4 Zone Controller Placement.......................

More information

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION PRODUCT SELECTION DATA EASY INSTALLATION INSTALLATION, OPERATION AND CENTRAL AIR DIFFUSION MAINTENANCE INSTRUCTIONS LOW ENERGY CONSUMPTION IMPROVED COMFORT ELEGANT AIR INLET GRILLE EXTREMELY QUIET OPERATION

More information

Energy Control/Motorized Energy Control

Energy Control/Motorized Energy Control The patented Energy Control function allows the air flow to be adjusted easily to provide a comfortable indoor climate. This function also permits a choice of air flow patterns (two-way, one-way and intermediate

More information

MATRIX LLC LEVEL CONTROL PANEL

MATRIX LLC LEVEL CONTROL PANEL MATRIX LLC LEVEL CONTROL PANEL Installation Operation Maintenance Manual 1-26-09 REV-0.3 1 INDEX Introduction. 3 Product Configurations..... 4 I/O Descriptions. 8 Operation o Intercooler, Accumulator,

More information

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA Wall diffuser SVQC / Supply air unit SVQC + ATVA SVQC is a quiet supply air diffuser intended for mounting on a wall. The device is particularly

More information

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C ELECTRIC POWER REGULATION STS converts 0 10 V signal to one time proportional and up to 3 contact. Each step must be identical in power. input output 1 2- number of steps 2 Vac, 1 VA 0 10 Vdc < 1 ma for

More information

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories HFB Airflow Management Damper Control damper for different airflow and duct pressure control applications Pressure-independent operation Galvanised steel design Circular duct connection equipped with integrated

More information

Operations Manual OM

Operations Manual OM Operations Manual OM 1063-2 Daikin BACnet VAV Controller Model 2508024 Group: Applied Air Systems Part Number: OM 1063 Date: January 2017 Supercedes: OM 1063 Owner s Manual Table of Contents Introduction....

More information

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller LC-ZEC200-xxxx Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller Description The CCS Variable Air Volume (VAV) Zone Pressure Independent Damper Controllers

More information

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev / SSP-7080 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing USER MANUAL Rev.1.1 2007/04 7673-7080-0000 CONTENTS Warning, Cautions and Operating Conditions P.1 Introduction

More information

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output TCAF Series Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output Issue Date March 1, 2018 Features Ultra slim wall-mount unit to match any décor Large easy-to-read Liquid Crystal Display (LCD), with

More information

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and

More information

GRUNDFOS DATA BOOKLET. Control HVAC. For variable-primary-flow systems

GRUNDFOS DATA BOOKLET. Control HVAC. For variable-primary-flow systems GRUNDFOS DATA BOOKLET Control HVAC For variable-primary-flow systems Control HVAC Table of contents 1. Product description 3 Introduction..................................................................................

More information

Digital Room Thermostats with Touch Screen LCD

Digital Room Thermostats with Touch Screen LCD TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),

More information

PCT-3001 plus. Display LCD

PCT-3001 plus. Display LCD PCT3 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS DESCRIPTION Pressure controller for refrigeration systems capable to control suction (compressors) and discharge (fans) pressures. It is possible

More information

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology HGM501 Gen-set Controller USER MANUAL Smartgen Technology Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. OVERVIEW... 4 PERFORMANCE AND CHARACTERISTICS... 4 TECHNICAL DATA... 5 OPERATION... 6 4.1. BUTTON DESCRIPTION...

More information

LK Control v.3 & LK Control v.3 - RA

LK Control v.3 & LK Control v.3 - RA LK Control v.3 & LK Control v.3 - RA Design LK Control v. 3 and LK Control v.3 -RA is complete unit for outdoor temperature-compensated heat regulation, adapted and pre-programmed for LK s Floor Heating

More information

Description. functions including single duct pressure dependent or pressure independent systems.

Description. functions including single duct pressure dependent or pressure independent systems. Description The Meridian Basic control system converts a single zone HVAC unit into a variable air volume/variable air temperature multiple zone system. The microprocessor based Zone Manager calculates

More information

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE 012945A0 040906 1 MAIN FEATURES Power supply 230V~ ±10% 50Hz Backlit alphanumeric LCD display Management of 5 output

More information

AIR VOLUME TRANSMITTER / CONTROLLER IML

AIR VOLUME TRANSMITTER / CONTROLLER IML 1131.60en 03.04.2013 AIR VOLUME TRANSMITTER / CONTROLLER IML IML air volume transmitter is designed for detecting and controlling air volumes in air handling units and room spaces. Air volumes are calculated

More information

Ventilation Control. Ventilation Control 12

Ventilation Control. Ventilation Control 12 Ventilation Control One of our major markets is building automation where our sensors control individual fans, dampers, valves, etc. A common application is controlling ventilation in rooms with varying

More information

SE7200 Series Installation Guide

SE7200 Series Installation Guide SE7200 Series Installation Guide 24 VAC Low Voltage Zoning Terminal Equipment Controller For Commercial HVAC Applications CONTENTS Installation 2 Preparation 2 Location 2 Installation 2 Configurable BI/UI

More information

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper Halton HFB Airflow Management Damper Control damper for different airflow and duct pressure control applications Pressure-independent operation Galvanised steel design Circular duct connection equipped

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC APPLICATION GUIDE Simplicity LINC GATEWAY OVERVIEW The Simplicity LINC Gateway operates as a Modbus Client providing an interface between a MS/TP control system and devices that communicate using the Modbus

More information

Temperature Controller (Heat Pumps)

Temperature Controller (Heat Pumps) 3 345 Temperature Controller (Heat Pumps) For comfort control in HVAC systems RWD31 RWD41 Stand-alone electronic temperature controller Four 2-position (On/Off) outputs Easy adjustment of parameters via

More information

The S Series unit is a ceiling mounted unit that comes in 3 sizes S1500, S1200 and S1000.

The S Series unit is a ceiling mounted unit that comes in 3 sizes S1500, S1200 and S1000. 16 The S Series unit is a ceiling mounted unit that comes in 3 sizes S1500, S1200 and S1000. The S1500 has been designed to ventilate a room with occupancies from 35 to 100 people, the S1200 for spaces

More information

lindab comfort Regula Control er

lindab comfort Regula Control er lindab comfort Regula Controller Regula Controller Control equipment for waterborne cooling and heating systems. Use Regula Mono, Duo and Regula Lon control the cooling and heating of a room in sequence

More information

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3.

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3. MANUAL INSTALLATION Tracking Controller TC Series v100 Issue Date: 02/25/16 2016 Price Industries Limited. All rights reserved. Firmware: 1.3.0 TABLE OF CONTENTS Product Overview General...1 Tracking Controller

More information

Accessories STRA Room Controller

Accessories STRA Room Controller Accessories STRA Room Controller External temperature sensor, STRZ-5-b Technical data room sensor: STRZ-5-5 C PT, DIN class B IP Technical data external sensor: STRZ-5-2 - +7 C PT, DIN class B Technical

More information

USERS MANUAL MCD REMOTE OPERATOR

USERS MANUAL MCD REMOTE OPERATOR USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3

More information

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features Product Guide ALC-PRM-VFC Ceiling Mounted Photocell Overview The ALC-PRM-VFC photocell will turn lighting on when the ambient light falls below a preset level. The lighting will then be turned off when

More information

HWS Heater (alternative) Electric Heater Stage 2 IQLVAV Electric Heater Stage 1. , P Serial Fan on/off SUPPLY AIR. Parallel Fan

HWS Heater (alternative) Electric Heater Stage 2 IQLVAV Electric Heater Stage 1. , P Serial Fan on/off SUPPLY AIR. Parallel Fan Data Sheet Variable Air Volume Strategy HWS Heater (alternative) Electric Heater Stage 2 IQLVAV Electric Heater Stage 1, P Serial Fan on/off Variable Fan damper Lon 2, 3, 4-port modulating valve Variable

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING AUGUST, 2004 REV.A CURTIS TOLEDO OPERATOR S MANUAL SUPPLEMENT AF Series Compressors VS models with VFD WARNING Personal injury and/or equipment damage will result by failing to pay attention to the vital

More information

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION Master Slave 1 Slave (n + 1) Master Slave 1 Slave (n + 1) Simplified Master / Slave operation GENERAL is a CIAT electronic control system designed to control non-independent air conditioning terminal units

More information

ELECTRONIC THERMOSTAT: T901

ELECTRONIC THERMOSTAT: T901 μnistδt ELECTONIC THEMOSTAT: T One contact output DESCIPTION The T series proportional thermostats are microcomputer based, proportional and integral (PI) devices with one contact time proportioning output.

More information

OPERATING INSTRUCTIONS ECON-M

OPERATING INSTRUCTIONS ECON-M OPERATING INSTRUCTIONS ECON-M INDEX 1.0 Introduction 2.0 Salient features, Protection & Supervision 3.0 Display/ Front Panel 4.0 Switches Description 5.0 LED Annunciations Description 6.0 Lamp Test 7.0

More information

Installation Instructions

Installation Instructions Installation Instructions Power Exhaust Part Numbers: CRPWREXH07A00 THROUGH CRPWREXH079A00 Conversion Package Numbers: CRPECONV005A00, CRPECONV006A00 CONTENTS Page SAFETY CONSIDERATIONS......................

More information

Fire damper FK120/FK90 TECHNICAL DATA

Fire damper FK120/FK90 TECHNICAL DATA Fire damper FK120/FK90 TECHNICAL DATA 2 Fire damper FK120/FK90 Figure 1 ER1 Figure 2 ER3 The rectangular fire damper FK120/FK90 is available both as motorized and with fuse. The damper casing is manufactured

More information

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes Sorensen XG 1700 Series 1700 W 1700 Watt, 1U Programmable DC Power Supplies 6 600 V Industry Leading Power Density Up to 1700 Watts in 1U Standard Digital Interfaces USB&RS232/485 LXI Ethernet and Isolated

More information

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift) First, Sign and Date Bln 2009-03-9 Updated, Sign and Date Bln 200-04-29 (0) User Manual TTT802 Gearshift Controller Firmware for R--N-2- TTT802 Gearshift Controller, Part # 2-620-9-RN-S (Standard), -P

More information

VTZ variable speed Reciprocating compressors

VTZ variable speed Reciprocating compressors MAKING MODERN LIVING POSSIBLE Application guidelines VTZ variable speed Reciprocating compressors R404A, R507, R407C, R134a www.danfoss.com CONTENT VARIABLE SPEED COMPRESSORS... 4 Speed control...4 Advantages

More information

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102*

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102* User Guide ECL Apex 10 *087R9745* *vijem102* Installation and configuration VI.JE.M1.02 Danfoss 11/2004 DH-SMT VI.JE.M1.02 Danfoss 11/2004 DH-SMT ECL Apex 10 VI.JE.M1.02 Danfoss 11/2004 DH-SMT VI.JE.M1.02

More information

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0 APP EOLE4 Applicable to program versions TAC5 Version DT 2.8.2 & DG 2.7.0 2 THE APP EOLE4 INTERFACE This interface can be used on Android, IOS and PC. Download the app from the App Store/Google Play or

More information

TE2010-GE Instructions manual

TE2010-GE Instructions manual TE2010-GE Instructions manual Hardware: 3.1-4.0 Software: 3.7 PREFACE Thanking you for preference, TECNOELETTRA SRL hopes that the use of this equipment could be a reason of satisfaction. This manual is

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

Plenum box ATTD TECHNICAL DATA

Plenum box ATTD TECHNICAL DATA Plenum box ATTD TECNICAL DATA 2 Plenum box ATTD Marine version ATTD is a plenum box for all types of air diffusers and is applicable for supply and exhaust air alike. The diffuser connection collar is

More information

RVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems.

RVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems. RVP-R VAV REGUATORS Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems. Intended use VAV regulators are used for automatic airflow regulation

More information

PROFESSIONAL 270 o PIR MOTION DETECTOR

PROFESSIONAL 270 o PIR MOTION DETECTOR PROFESSIONAL 270 o PIR MOTION DETECTOR The unit can be installed only vertically (see the FIGURE 1A), not upside-down or horizontally (see the FIGURE 1B) as shown in the below drawing. FIGURE 1A 1. Motion

More information

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,

More information

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0 Product Manual Part Number: MVP-193 Mefi-6 ECU Revision: 1.0 Copyright Controls, Inc. P.O. Box 368 Sharon Center, OH 44274 Phone 330.239.4345 Fax 330.239.2845 www.controlsinc.com TABLE OF CONTENTS PRIOR

More information

PIR Ready VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications (Issue Date June 12, _R2)

PIR Ready VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications (Issue Date June 12, _R2) Product overview PIR Ready VT7200 Series Low Voltage Zoning Thermostats For mercial HVAC Applications (Issue Date June 12, 2008 028-0190_R2) The VT7200 PI thermostat family is specifically designed for

More information

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets 86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module

More information

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

RWBa. ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. RWBa

RWBa. ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. RWBa ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. ROOM CONTROL EQUIPMENT RWBa For sequential control of heating and cooling, or cooling/ heating only. Electromechanical actuators provide

More information

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA SmartVFD HVAC APPLICATION The SmartVFD HVAC is a variable frequency drive designed for use in HVAC application to control the speed of HVAC pumps and fans in order to maximize energy efficiency. Smart

More information

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO:

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO: YMC 2 - MOD A STARTUP CHECKLIST Supersedes 160.78-CL2 (512) Form 160.78-CL2 (615) STARTUP CHECKLIST CUSTOMER: JOB NAME: ADDRESS: LOCATION: PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT

More information

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W) CIRCUIT-TEST Switching Mode Power Supply with Remote Sensing PSC-9800 0-16V 5A / 0-27V 3A / 0-36V 2.2A (80W) OPERATION MANUAL 1 2 PSC-9800 08R14 Contents Safety Precautions...page 4 Introduction... 5 Controls

More information

BUILDING AUTOMATION CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE Intelligent solutions for intelligent people.

BUILDING AUTOMATION CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE Intelligent solutions for intelligent people. BULDNG AUTOMATON CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE 2015 ntelligent solutions for intelligent people. ALRE-T Regeltechnik GmbH Your reliable partner. Soon, Alre T-Regeltechnik GmbH

More information

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9. SED2 with Conventional Bypass Options Important Note: VD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies

More information

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules Technical Specification Sheet Document No. 149-855 November 04, 2015 BACnet Lab and Pressurized Room Controllers with Off-board Air Modules NOTE: The 570-8xxPA BACnet laboratory controllers have new 67xx

More information

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

Te 803 Electronic Controller. Service, Operation & Technical Information Manual Te 803 Electronic Controller Service, Operation & Technical Information Manual WARNING! Technical descriptions and data given in this document are accurate, to the best of our knowledge, but can be subject

More information

DTR CG OPTIMA ver.3.0 ( )

DTR CG OPTIMA ver.3.0 ( ) Compact controlling units of supply as well as supply and exhaust air-handling units VS 10 75 CG OPTIMA VS 40 150 CG OPTIMA SUP VS 40 150 CG OPTIMA SUP EXH Operating and maintenance manual DTR CG OPTIMA

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing

More information

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals IO Input/Output Modules IO-ABM4 Analogue Override Module Description IO-ABM4 Analogue Override Module Intended for applications which require independent manual override of analogue output channels from

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10)

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10) APPLICATION NOTES Industrial Wall Control (IWC0) (English) (IWC0) The Breezair Industrial Wall Control (IWC0) is designed to provide both local and external Evaporative Air cooler control for all Breezair

More information

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233 September 2012 / Bulletin 100-50-6.2 PSK203/PSK223/PSK233 Digital Thermostats f Low Temperature Refrigerating Units INSTALLATION OPERATING INSTRUCTIONS 1 GETTING STARTED 1.1 Imptant Read these instructions

More information

Version 11 Controls for natural ventilation. NV Comfort Standard / Plus KNX control

Version 11 Controls for natural ventilation. NV Comfort Standard / Plus KNX control Version 11 Controls for natural ventilation NV Comfort Standard / Plus KNX control NV Comfort software card 230V 1.20 NV Comfort basis package Application central control of indoor climate with the potential

More information

VMB1TS Temperature sensor module for the Velbus system

VMB1TS Temperature sensor module for the Velbus system VMB1TS Temperature sensor module for the Velbus system VMB1TS manual edition 2 1 CONTENTS DESCRIPTION... CHARACTERISTICS... VELBUS CHARACTERISTICS... 5 OVERVIEW SENSOR MODULE... 7 EMBEDDING THE TEMPERATURE

More information

Water Specialist EE Control Valve Programming and Cover Drawing Manual

Water Specialist EE Control Valve Programming and Cover Drawing Manual Water Specialist EE Control Valve Programming and Cover Drawing Manual Page 2 EE Man u al EE Man u al Page 3 Table of Contents EE Front Cover and Drive Assembly... 4 Regeneration and Error Screens, Button

More information