PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233

Size: px
Start display at page:

Download "PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233"

Transcription

1 September 2012 / Bulletin PSK203/PSK223/PSK233 Digital Thermostats f Low Temperature Refrigerating Units INSTALLATION OPERATING INSTRUCTIONS 1 GETTING STARTED 1.1 Imptant Read these instructions carefully befe installing operating this controller follow all additional infmation f installation electrical connection. Keep this guide f future reference. accding to the safety regulations, the protection against touching electrical parts must be ensured by proper installation of the device; the parts that ensure this protection must be installed so that they can not be removed without the use of a tool. 1.3 Wiring diagram 1.2 Installing the controller Size - mm (inches) 33.0 (1.299) Electrical Connection PSK203 PSK203 K1 K3 K2 max. 10 A (2.322) 75.0 (2.952) panel cut out A B power supply cabinet evap. comp. evap. fan defrost electric system 83.0 (3.267) Dimension Minimum Typical Maximum mm inches mm inches mm inches A B PSK223 max. 10 A K2 K1 K3 PSK serial pt Installation - Panel mounting, with click brackets (supplied by the builder). electric system defrost comp. evap. fan power supply evap. cabinet multip./do switch PSK233 K3 K1 K2 max. 10 A PSK233 serial pt Additional infmation f installation: 59.0 mm (2.322 inches) is the maximum depth with screw terminal blocks 83.0 mm (3.267 inches) is the maximum depth with extractable terminal blocks the panel thickness must not be greater than 8.0 mm (0.314 in) wking conditions (wking temperature, humidity, etc.) must be between the limits indicated in the technical data do not install the controller close to heating sources (heaters, hot air ducts, etc.), devices provided with large magnets (speakers, etc.), locations subject to direct sunlight, rain, humidity, dust, mechanical vibrations bumps power supply evap. fan comp. defrost Additional infmation f electrical connection: do not use electric/pneumatic screwdrivers/wrenches on the terminal blocks if the controller has been moved from a cold location to a warm one, condensation can occur on the inside of the unit; wait at least one hour befe attempting to power up use the controller multip./do switch cabinet evap.

2 Page 2 Bulletin make sure that the supply voltage frequency are crect f the power supply of the controller : LED will flash always disconnect power from the controller befe servicing it do not operate f 15 seconds. this controller is not intended to be used as a safety control device You also can modify the wking setpoint through parameter SP. within 15 seconds; also look at parameters r1, r2 r3 f repair servicing, contact your Parker Splan Sales Engineer first. 3.2 Setting configuration parameters 2 USER INTERFACE To gain access to the procedure: make sure no procedure is running 2.1 Turning on/off the controller hold The unit is turned on when power is supplied to it, likewise turns off when power is removed. Through the digital input it is also possible to turn off the controller remotely via software; in this case the controller remains connected to the power supply the regulats are turned off. f 4 seconds: the display will show PA within 15 seconds to set display to -19 do not press any other button f 15 seconds hold f 4 seconds: the display will show SP. To select a parameter: 2.2 The display If the controller is turned on, during the nmal operation the display will show the quantity set f parameter P5. To modify a parameter: 2.3 Showing the temperatures read by the probes make sure the keyboard is not locked no procedure is running press do not press any other button f 15 seconds. hold available label To quit the procedure: f 2 seconds: the display will show the first p ress to select Pb1 (cabinet probe), Pb2 (evapat probe) Pb3 (condenser probe) To quit the procedure: do not operate f 60 seconds press as long as the display shows the quantity you have set with parameter P5 do not operate f 60 seconds. If the evapat probe is not enabled (parameter P3 = 0), the label Pb2 will not be shown. If the condenser probe is not enabled (parameter P4 = 0), the label Pb3 will not be shown. within 15 seconds hold button f 60 seconds. f 4 seconds do not press any other Switch off/on the power supply of the controller after the modification of the parameters. 3.3 Resting the default value of configuration parameters make sure no procedure is running hold f 4 seconds: the display will show PA do not press any other button f 15 seconds hold within 15 seconds to set the display to 743 f 4 seconds: the display will show def 2.4 Activating the defrost by h make sure the keyboard is not locked no procedure is running do not press any other buttons f 15 seconds: the press display will flash def f 4 seconds, after which the controller will quit the procedure hold f 4 seconds. If the function of the evapat probe is the one of defrost probe (parameter P3 = 1) to the defrost activation the evapat temperature is above the one you have set with parameter d2, the defrost will not be activated. within 15 seconds to set the display to 149 switch the controller off then back on after these procedures then confirm that the default values have been reset. Make sure the default value of the parameters is crect, in particular note if the probes are PTC probes. 2.5 Locking/unlocking the keyboard To lock/unlock the keyboard: make sure no procedure is running p ress hold f 2 seconds: the display will show Loc / UnL f 1 second 2.6 Silencing the alarm make sure no procedure is running press (but do not hold) any button (pressing any button without holding it will not initiate the nmal comm f that button). 3 SETTINGS 3.1 Setting the wking setpoint make sure the keyboard is not locked no procedure is running 4 SIGNALS 4.1 Signals LED INDICATIONS LED compress if lit, the compress will be turned on if flashing: the modification of the wking setpoint will be running a compress protection will be running (parameters C0, C1, C2 i7) LED defrost if lit, the defrost will be running if flashing: the defrost will be required but a compress protection will be running (parameters C0, C1 C2)

3 Bulletin Page 3 the drip cycle will be running (parameter d7) the heating of the freezing fluid will be running (parameter da) LED evapat fan if lit, the evapat fan will be turned on if flashing, after the drip cycle evapat fan delay will be running (parameter F3) LED alarm if lit, an alarm will be running C C LED if lit, the unit of measure of the temperatures will be degree Celsius (parameter P2) F F LED if lit, the unit of measure of the temperatures will be degree Fahrenheit (parameter P2) CODE EXPLANATION Loc the keyboard / the wking setpoint are locked (parameter r3); also look at paragraph ALARMS 5.1 Alarms CODE MEANING AL Low temperature alarm (parameters A0, A1 A2) AH High temperature alarm (parameters A3, A4 A5) id Do switch input alarm (parameters i0 i1) ia Multipurpose input alarm (parameters i0, i1 i5) isd Controller locked alarm (parameters i0, i1, i5, i7, i8 i9) COH Overheated condenser alarm (parameter C6) CSd Compress locked alarm (parameter C7) When the cause of the alarm disappears, the controller restes to nmal operation, except f the controller locked alarm (code isd ) the compress locked alarm (code CSd ). These alarms can only be reset by switching the power supply to the controller off/on. 6 INTERNAL DIAGNOSTICS 6.1 Internal diagnostics CODE EXPLANATION Pr1 Cabinet probe err (parameter P0) Pr2 Evapat probe err (parameter P0) When the cause that initiated the alarm is crected, the controller returns to nmal operation. 7 TECHNICAL DATA 7.1 Technical data Frontal bezel protection: IP 65. Connections (use copper conducts only): screw terminal blocks (power supply, inputs outputs) on PSK203; extractable terminal blocks on PSK223 PSK233. Wking temperature: from 0 to 55 C (32 to 131 F) 10 to 90% of relative humidity without condensate). Power supply: 115 VAC/230 VAC, 50/60 Hz, 3 VA (approximate). Insulation class: 2. Alarm buzzer: present on PSK223 PSK233. Measure inputs: 2 (cabinet probe evapat probe) f PTC/ NTC probes. Digital inputs (only PSK223 PSK233): 1 (multipurpose/do switch) f NO/NC contact (5V, 1 ma). Wking range: from to C (-50 to 300 F) f PTC probe, from to C (-40 to 220 F) f NTC probe. Resolution: 0.1 C/1 C/1 F. Digital outputs - 3 relays: compress relay: 16 res. 250 VAC, 5 FLA, 30 LRA (NO contact) in PSK203; 30 res. 250 VAC, 12 FLA, 72 LRA (NO contact) in PSK233; 8 res. 250 VAC, 2 FLA, 12 LRA otherwise defrost relay: 8 res. 250 VAC, 2 FLA, 12 LRA (change-over contact) evapat fan relay: 8 res. 250 VAC, 2 FLA, 12 LRA (NO contact) in PSK203; 5 res. 250 VAC otherwise. The maximum current allowed on the load is 10 A. Serial pt: pt f communication with a management system (through a serial interface, via TTL, with MODBUS communication protocol) with the programming key; not available in PSK CONFIGURATION PARAMETERS 8.1 Configuration parameters Parameters Minimum Maximum U.M. DEF. Wking Setpoints SP r1 r2 C/ F 0.0 wking setpoints Parameters Minimum Maximum U.M. DEF. Temperature Inputs CA C/ F 0.0 cabinet probe offset CA C/ F 0.0 evapat probe offset P kind of probe 0 = PTC 1 = NTC P P display decimal point value during nman operation (Celsius mode only) 1 = YES unit of measure, temperature 0 = C 1 = F

4 Page 4 Bulletin Configuration parameters (continued) Parameters Minimum Maximum U.M. DEF. Temperature Inputs (continued) P P evapat probe function 0 = probe not enabled 1 = defrost probe thermostat probe f the evapat fan 2 = thermostat probe f the evapat fan quantity to show during the nmal operation 0 = cabinet temperature 1 = wking setpoint 2 = evapat temperature 3 = cabinet temperature - evapat temperature Parameters Minimum Maximum U.M. DEF. Setpoints r C/ F 2.0 wking setpoint differential r r2 C/ F minimum wking setpoint r2 r C/ F 50.0 maximum wking setpoint r r C/ F 0.0 Parameters Minimum Maximum U.M. DEF. Compress Protections lock the wking setpoint (with the procedure related in paragraph 3.1) 1 = YES temperature increase during Energy Saving function (only PSK223 PSK233); also look at i5 C min 0 compress delay after turning on the controller C min 5 minimum time between two activations in succession of the compress; also compress delay from the end of the cabinet probe err C min 3 minimum time the compress remains turned off C s 0 minimum time the compress remains turned on C min 10 time the compress remains turned off during the cabinet probe err; also look at C5 C min 10 time the compress remains turned on during the cabinet probe err; also look at C4 Parameters Minimum Maximum U.M. DEF. Defrost d h 8 defrost interval; also look at d8 0 = the defrost at intervals will never be activated d kind of defrost 0 = electric defrost 1 = hot gas defrost d C/ F 2.0 defrost termination temperature (only if P3 = 1) d min 30 d defrost duration if P3 = 0 2; defrost maximum duration if P3 = 1 0 = defrost will never be activated defrost when you turn on the controller 1 = YES d min 0 defrost delay when you turn on the controller (only if d4 = 1); also look at i5 d d min 2 drip duration d d C/ F 0.0 temperature shown during the defrost 0 = cabinet temperature 1 = if, upon activation of defrost, the cabinet temperature is below wking setpoint + r0, at most wking setpoint + r0 ; if, upon activation of defrost, the cabinet temperature is above wking setpoint + r0, at most the cabinet temperature to the defrost activation kind of defrost interval 0 = the defrost will be activated when the controller has remained turned on f time d0 1 = the defrost will be activated when the compress has remained turned on f time d0 2 = the defrost will be activated when the evapat temperature has remained below temperature d9 f time d0 evapat temperature above which the count of the defrost interval is suspended (only if d8 = 2) da 0 99 min 0 minimum time the compress must remain turned on befe defrost can be activated (only if d1 = 1)

5 Bulletin Page Configuration parameters (continued) Parameters Minimum Maximum U.M. DEF. Temperature Inputs Alarms(continued) A measured input used f the low temperature alarm 0 = cabinet temperature 1 = evapat temperature A C/ F temperature below which the low temperature alarm is activated; also look at A0 A2 A kind of lower temperature alarm 0 = alarm not enabled 1 = relative to the wking setpoint ( wking setpoint - A1 ; consider A1 without sign) 2 = absolute ( A1) A C/ F 10.0 temperature above which the high temperature alarm is activated; also look at A3 A5 A kind of upper temperature alarm 0 = alarm not enabled 1 = relative to the wking setpoint ( wking setpoint + A4 ; consider A4 without sign) 2 = absolute ( A4) A min 120 high temperature alarm delay since you turn on the controller (only if A3 = 0) A min 15 temperature alarm delay A min 15 high temperature alarm delay since the end of the after dripping evapat fan delay (only if A3 = 0) A min 15 high temperature alarm delay since the deactivation of the do switch input (only PSK223 PSK233) Parameters Minimum Maximum U.M. DEF. Evapat Fan F evapat fan activity during the nmal operation 0 = turned off 1 = turned on 2 = accding to the compress 3 = accding to F1 4 = turned off if the compress is turned off; accding to F1 if the compress is turned on F C/ F -1.0 evapat temperature above which the evapat fan is turned off (only if F0 = 3 4) F evapat fan activity during defrost drip delay 0 = turned off 1 = turned on 2 = accding to F0 F min 2 fan delay after evapat drip completes Parameters Minimum Maximum U.M. DEF. Digital Inputs Only PSK223 PSK233 i kind of digital input 0 = MULTIPURPOSE INPUT - in this case look at parameters i1, i5, i7, i8 i9 1 = RESERVED 2 = DOOR SWITCH INPUT - in this case look at parameters i1, i2 i3; the activation of the input will turn off the evapat fan (f at most time i3 until the input is deactivated) 3 = DOOR SWITCH INPUT - in this case look at parameters i1, i2 i3; the activation of the input will turn off the compress the evapat fan (f at most time i3 until the input is deactivated) i digital input contact type 0 = NO (the input will be active if you close the contact) 1 = NC (the input will be active if you open the contact) 2 = input not enabled i min 30 delay befe the do switch alarm is activated -1 = no signal i min 15 maximum duration of the effect provoked by the activation of the do switch input -1 = the effect will last as long as the input will be deactivated i effect provoked by the activation of the multipurpose input 0 = no effect 1 = SYNCHRONIZING THE DEFROSTS - after time d5, the defrost will be activated 2 = ACTIVATING ENERGY SAVING - Energy Saving function will be activated (until the input is deactivated); also look at r4 3 = ACTIVATING THE EXTERNAL ALARM - after time i7, the display will flash the code ia the buzzer will be activated (until the input is deactivated) 4 = ACTIVATING THE COMPRESSOR LOCKOUT - the compress will be turned off, the display will flash the code ia the buzzer will be activated (until the input is deactivated); also look at i7, i8 i9 5 = TURNING OFF THE CONTROLLER - the controller will be turned off via software (until the input is deactivated); also look at C0, d4 A6 6 = ACTIVATE COOLING (only PSK223 PSK233) - the compress will be turned on (until the input is deactivated); in this case parameters C4 C5 are not meaningful

6 Page 6 Bulletin Configuration parameters (continued) Parameters Minimum Maximum U.M. DEF. Digital Temperature Inputs Inputs Only (continued) PSK223 PSK233 (continued) i min 0 i i min 240 if i5 = 3, delay befe the multipurpose input alarm is activated if i5 = 4, compress delay after the deactivation of the multipurpose input number of multipurpose input alarms such as to provoke the controller locked alarm (only if i5 = 4) 0 = alarm not enabled time without multipurpose input alarms such as to provoke the alarm counter to be cleared (only if i5 = 4) Parameters Minimum Maximum U.M. DEF. Serial Netwk Only PSK223 PSK233 LA controller address Lb baud rate 0 = 2,400 baud 1 = 4,800 baud 2 = 9,600 baud 3 = 19,200 baud LP parity 0 = none 1 = odd 2 = even Parameters Minimum Maximum U.M. DEF. Reserved E reserved

7

8 WARNING USER RESPONSIBILITY Failure improper selection improper use of the products described herein related items can cause death, personal injury property damage. This document other infmation from Parker Hannifin Cpation, its subsidiaries authized distributs provide product system options f further investigation by users having technical expertise. The user, through its own analysis testing, is solely responsible f making the final selection of the system components assuring that all perfmance, endurance, maintenance, safety warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry stards, follow the infmation concerning the product in the current product catalog in any other materials provided from Parker its subsidiaries authized distributs. To the extent that Parker its subsidiaries authized distributs provide component system options based upon data specifications provided by the user, the user is responsible f determining that such data specifications are suitable sufficient f all applications reasonably feseeable uses of the components systems. F safety infmation see the Safety Guide at call CParker Parker Hannifin Cpation. Bulletin / Parker Hannifin Cpation Splan Division 206 Lange Drive, Washington, MO USA phone fax

Pulse Width Modulation Valves. Models SPW-0 thru -7

Pulse Width Modulation Valves. Models SPW-0 thru -7 November 2017 Bulletin / Bulletin 30-30 30-30 Page 1 Pulse Width Modulation s Models SPW-0 thru -7 Page 2 Bulletin 30-30 Pulse Width Modulation s For Refrigerant Flow Control in Direct Expansion HFC, HCFC

More information

TD320 Differential Temperature Controller For HVAC

TD320 Differential Temperature Controller For HVAC AUBER INSTRUMENTS Instruction Manual WWW.AUBERINS.COM TD320 Differential Controller F HVAC Version 1.2 (Oct, 2017) 1. Overview TD320 is a temperature controller f heating, ventilating, and air-conditioning

More information

ST Wiring diagram. Product description. Temperature controller. Order number

ST Wiring diagram. Product description. Temperature controller. Order number ST7-31.3 Temperature controller Order number 9154.12 Wiring diagram Product description The switching exits of the thermostatic controller can be programmed as -two-point controller with alarm -three-point

More information

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and

More information

Sporlan Gas Cooler/ Flash Gas Bypass Valves

Sporlan Gas Cooler/ Flash Gas Bypass Valves Sporlan Gas Cooler/ Flash Gas Bypass Valves For Transcritical CO 2 (R-744) Applications August 14 / Bulletin 100-80 Page 2 Bulletin 100-80 Bulletin 100-80 Page 3 GAS COOLER/FLASH GAS BYPASS VALVES The

More information

Ventilation in balance

Ventilation in balance Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR MODBUS RTU RS485 BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer. The firmware

More information

Indoor air quality sensor.

Indoor air quality sensor. Indoor air quality sensor. Options and Accessories, Installation manual Ref.: N-40175_EN 1107 Index Index 1 Indoor air quality sensor... 1 1.1 General Information... 2 1.2 General measurements... 2 1.3

More information

RDG160TU Commercial Thermostat

RDG160TU Commercial Thermostat Document No. 129-588 RDG160TU Commercial Thermostat Selecting Location Install the thermostat about 4 feet (120 cm) above the floor on an inside wall. Ensure that there is free airflow around the thermostat.

More information

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Instruction Manual SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.14 (August, 215) 1. Caution 3. Terminal Assignment Model SWA-2441 Model SWA-2451 This controller is intended to

More information

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. User manual Manual version: 2.4 dated 27/02/08 Program code: FLSTDmMCDE LEGGI

More information

Electric Expansion Valves

Electric Expansion Valves Electric Expansion s Bulletin 100-20-1, January 2011 Page 2 Bulletin 100-20-1UK This supplement to Bulletin 100-20 (September 2008) details the updated Sporlan series of Electric Expansion s. Built on

More information

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS Date of last update: Apr-15 Ref: D7.8.4/0112-0415/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors...

More information

SWA-24X2C PID Temperature Controller with Timer (SWA-2442C/2452C)

SWA-24X2C PID Temperature Controller with Timer (SWA-2442C/2452C) Instruction Manual SWA-24X2C PID Temperature Controller with Timer (SWA-2442C/2452C) Version 1.4 (v, 2016) 1. Caution This controller is intended to control equipment under normal operating conditions.

More information

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE 012945A0 040906 1 MAIN FEATURES Power supply 230V~ ±10% 50Hz Backlit alphanumeric LCD display Management of 5 output

More information

KE2 Temp + Defrost (pn 20611) Installation Manual

KE2 Temp + Defrost (pn 20611) Installation Manual Q.1.20 February 2013 (pn 20611) Installation Manual This reference should remain on site with the installed controller. B E A C F D What s in the Kit - Parts List The following parts are included in the

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

WARNING User Responsibility

WARNING User Responsibility WARNING User Responsibility FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

HWP Protection Board

HWP Protection Board February 2009 HWP Protection Board Features and Operation This board provides the system protection features necessary to keep our HWP (Water Sourced Heat Pump) units safe in the instances when they are

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL Temperature Controller TC5+2V4SA Plus USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject

More information

PCT-3001 plus. Display LCD

PCT-3001 plus. Display LCD PCT3 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS DESCRIPTION Pressure controller for refrigeration systems capable to control suction (compressors) and discharge (fans) pressures. It is possible

More information

Modbus Integration Integration for Modbus Functionality for VT8600 Series

Modbus Integration Integration for Modbus Functionality for VT8600 Series Modbus Integration Integration for Modbus Functionality for VT8600 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS

More information

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING AUGUST, 2004 REV.A CURTIS TOLEDO OPERATOR S MANUAL SUPPLEMENT AF Series Compressors VS models with VFD WARNING Personal injury and/or equipment damage will result by failing to pay attention to the vital

More information

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves Check Valves Gauge Control Valves Colorflow Valves Colorflow and Ball Valves Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Ball Valves Fully guided poppets are used on

More information

Sandwich Valves Series CP

Sandwich Valves Series CP Technical Information General Description. pilot operated check valves are designed for maximum flow rates. The valves are typically used in combination with spool type directional control valves to ensure

More information

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target

More information

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

Electronic Refrigerator Diagnostics

Electronic Refrigerator Diagnostics Electronic Refrigerator Diagnostics IMPORTANT SAFETY NOTICE The information in this presentation is intended for use by individuals possessing adequate backgrounds of electrical, electronic, & mechanical

More information

SMT-150 Installer Manual

SMT-150 Installer Manual SMT-150 Installer Manual 3 Stage Digital HVAC Controller Version 1.0 Version History January 2019 Version 1 - Original Document Thank you for your purchase of this premier product. Please take the time

More information

RVS-DX Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

EM DC Multi-Function DC Energy Meter

EM DC Multi-Function DC Energy Meter Analogue Meters With Moving - Iron Movement EM DC Compact DC Energy Meter Ziegler EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Installation and Startup Manual Hydraulic Pumps Series VP1-095 /-110/ -130

Installation and Startup Manual Hydraulic Pumps Series VP1-095 /-110/ -130 Visit our homepage for additional support parker.com/pmde Installation and Startup Manual Hydraulic Pumps Series VP1-095 /-110/ -130 Effective: May 01, 2015 Supersedes: January 01, 2013 Important installation

More information

WP37 & HT37 User Manual

WP37 & HT37 User Manual WP37 & HT37 User Manual Origio WP37 & HT37 Warming Plates & Heated Trolley Warming Plates WP37 300 WP37 500 Heated Trolley HT37 Origio WP37 Component Description Heated work surface Model WP37 300 Power

More information

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and pushbutton setpoint adjustment. Additional options include pushbutton override, fan

More information

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Product Catalog NQ Series Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Page Intentionally Blank Contents Standard Features...1 Available Options...3 Oversized Pumps... 3 High Flow Unit

More information

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel 18/10 AISI 304 both in- and outside. All the internal corners

More information

USER MANUAL DCA15. Auto Aır Conditioner Controller Unit. Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17

USER MANUAL DCA15. Auto Aır Conditioner Controller Unit. Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17 USER MANUAL DCA15 Auto Aır Conditioner Controller Unit Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17 INDEX 1) GENERAL DESCRIPTION 2) BEFORE USING THE DEVİCE 3) SAFETY PRECAUTIONS 4)

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

MC 785-SC. Operating Manual (Wall and panel mounting) Type: MANUAL Number of pages: 32 Version: V2.3

MC 785-SC. Operating Manual (Wall and panel mounting) Type: MANUAL Number of pages: 32 Version: V2.3 MC 785SC Operating Manual (Wall and panel mounting) Description : MC 785SC Step Control Doc.nr.: 2291 Type: MANUAL Number of pages: 32 Version: V2.3 File: Do2291 MC785SC v23 EN.wpd Software: MC785SC V2.11

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

STRA-24 for chilled beams

STRA-24 for chilled beams STRA- Installation and commissioning manual STRA- for chilled beams STRA- is the room controller for the pressure independent (Pi) and constant air volume chilled beams. It is possible to set different

More information

Ventilation in balance

Ventilation in balance Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR BACNET TM /IP. BACNET TM MS/TP BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer.

More information

SERVICE MANUAL HOT DELI 3/4/5/7 MERCHANDISERS

SERVICE MANUAL HOT DELI 3/4/5/7 MERCHANDISERS SERVICE MANUAL HOT DELI 3/4/5/7 MERCHANDISERS VERSIONS Full service Full service humidified Self service HD 5 full service on pedestal underframe - NOTICE - This manual is prepared for the use of trained

More information

SMT-AZC INSTALLATION / OPERATION MANUAL

SMT-AZC INSTALLATION / OPERATION MANUAL SMT-AZC INSTALLATION / OPERATION MANUAL 22o OFF VERSION 2.0 www.smarttemp.com INTRODUCTION The SMT-AZC thermostat is designed to work with the Smart Temp 24Volt Zone Dampers TERMINAL DESIGNATIONS The SMT-AZC

More information

37. FATC (FULL AUTO TEMP. CONTROL) CIRCUIT 6810

37. FATC (FULL AUTO TEMP. CONTROL) CIRCUIT 6810 5156 6810 37. FATC (FULL AUTO TEMP. CONTROL) CIRCUIT 6810 1) CONDENSOR FAN, AIR MIX MOTOR, SUN SENSOR, WATER TEMP SENSOR A. CONNECTOR INFORMATION 6810 5157 Connector Number (Pin Number, Color) Connecting

More information

- Wiring Brochure tn4 Gateway 483

- Wiring Brochure tn4 Gateway 483 - Wiring Brochure Gateway 483 W 483 03/10 1 Infmation Brochure Application Brochure Choose controls to match application Design your mechanical applications 2 3 Rough-in Wiring Rough-in 4 Wiring Brochure

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power. Electric Freestanding Range Technical Information MER5875RA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer

More information

MagnePump. Recirculation MagnePumps. At a Glance:

MagnePump. Recirculation MagnePumps. At a Glance: MagnePump Recirculation MagnePumps Parker Autoclave Engineers MagnePumps eliminate or reduce many of the problems associated with conventional pumps, such as leakage, contamination and packing heat generation.

More information

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW) Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

Ucontrol. 1 Data sheet. Multipurpose controllers for variable voltage 3 ~ fans PXDM Examples of application. 1.2 Equipment / Function

Ucontrol. 1 Data sheet. Multipurpose controllers for variable voltage 3 ~ fans PXDM Examples of application. 1.2 Equipment / Function english Multipurpose controllers for variable voltage 3 ~ fans Ucontrol PXDM6..35 1 1.1 Examples of application Speed controller with manual adjustment of output voltage at the unit or via external signal,

More information

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media 120A and 120B Series Fuel Filter/Water Separators Instruction Part Number 10219 Rev B Overview: 120A and 120B fuel filter/water separators are designed to be installed on the suction side of the fuel system

More information

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications An ISO 9001:2008 Registered Company Idle Timer Controller - ITC515-A 2015-2018 Ford Transit Contact InterMotive for additional vehicle applications Overview The ITC515-A system will shut off gas or diesel

More information

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication

More information

G861 Series Integrated Function. Direct Spark Ignition Control

G861 Series Integrated Function. Direct Spark Ignition Control Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G861 Issue Date 0699 G861 Series Integrated Function Direct Spark Ignition Control Figure 1:

More information

Operation Manual. Temperature Controller ST49. Revision 1.1, dated on

Operation Manual. Temperature Controller ST49. Revision 1.1, dated on Operation Manual Temperature Controller ST49 Revision 1.1, dated on 31.03.2008 Contents 1. User Consideration...4 2. Product description and application...5 3. Controller architecture...5 4. Operation

More information

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007 Instruction Sheet PA-00281 October 2007 PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls THE FLEXIBLE

More information

Maintenance Instructions & Parts List

Maintenance Instructions & Parts List PM-PTR/LTR-C Automation Actuator Division Wadsworth, Ohio 448 October 7, 993 Rev. October 999 PTR/LTR Series Actuators Maintenance Instructions & Parts List Provide Model Number and Serial Number When

More information

Flight Systems. Replacement for KASSEC DESCRIPTION

Flight Systems.   Replacement for KASSEC DESCRIPTION DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most

More information

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS PCT plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS Ver. DESCRIPTION The PCT plus is a pressure controller for refrigeration plants that require control in their suction and discharge stages. With

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

Series P28. Oil Protection Controls. Feature and Benefits. P28DP Oil Protection Control (P) Setpoint adjusting cam

Series P28. Oil Protection Controls. Feature and Benefits. P28DP Oil Protection Control (P) Setpoint adjusting cam PSC9705 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P8 Series P8 Oil Protection Controls Introduction These oil protection controls are designed to give protection against

More information

TTM MODEL TTM TRANSFORMER TEMPERATURE MONITOR AND COOLING CONTROL SYSTEM. BCI Bulletin BCI-TTM-01 Revision 12/03/02

TTM MODEL TTM TRANSFORMER TEMPERATURE MONITOR AND COOLING CONTROL SYSTEM. BCI Bulletin BCI-TTM-01 Revision 12/03/02 MODEL TRANSFORMER TEMPERATURE MONITOR AND COOLING CONTROL SYSTEM BCI Bulletin BCI--01 Revision 12/03/02 CONTENTS Page I. Description of Operation 2 Main menu & keypad 4 Configuration menu & lookback example

More information

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC APPLICATION GUIDE Simplicity LINC GATEWAY OVERVIEW The Simplicity LINC Gateway operates as a Modbus Client providing an interface between a MS/TP control system and devices that communicate using the Modbus

More information

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana Introduction An ISO 9001:2015 Registered Company Idle Timer Controller - A-ITC620-A1 2009-2019 Chevrolet Express/GMC Savana Contact InterMotive for additional vehicle applications The A-ITC620-A1 is an

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power. Electric Freestanding Range Technical Information AER5712BA* MER5751BA* MER5752BA* MERH752BA* MERM752BA* Due to possibility of personal injury or property damage, always contact an authorized technician

More information

TECHNICAL MANUAL SOFFIO Ducted units

TECHNICAL MANUAL SOFFIO Ducted units TECHNICAL MANUAL SOFFIO Ducted units Page 1 INDEX 1-INTRODUCTION... 4 2-OPERATING LIMITS... 4 3- KEY TO READING CODES... 5 4-TECHNICAL SPECS... 6 5-TECHNICAL DATA (AC motors)... 7 5.1-Unit 2 pipes with

More information

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass SED2 VD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass Description The NEMA Type 3R Bypasses are companion packages for the family of SED2 Variable requency Drives (VD). NEMA Type 3R/3RHE enclosed

More information

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller

More information

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1. Thermo-cooler Series HRGC Specifications HRGC//5 Cooling method Refrigerant Control method Ambient temperature/humidity Circulating fluid Note ) Temperature range setting Note ) C Cooling capacity Note

More information

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual. Chiller SWS/SWR 1602 to 4802 Water Cooled Chillers Only and Condenserless Versions Engineering Data Manual 272 to 1118 kw Specifications General The SWS water cooled screw chillers are equipped with high

More information

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

SINUS PENTA 2T/4T SINUS PENTA 2T/4T SINUS PENTA 2T/4T SINUS PENTA 2T/4T Technical Highlights One product, 5 integrated functions - IFD (Inverter Frequency Drive): vector modulation function for general-purpose applications (V/F pattern).

More information

Remote Temperature Controllers. Quick Selection Guide

Remote Temperature Controllers. Quick Selection Guide Remote Temperature Controllers Quick Selection Guide A Complete Selection For A Wide Range Of Applications Electronic Standalone Controllers T775 Provide on/off, modulating, or reset control in applications

More information

Adjustable PT100 Bearing Temperature Sensor with ½ NPT Conduit Entry

Adjustable PT100 Bearing Temperature Sensor with ½ NPT Conduit Entry Adjustable PT100 Bearing Temperature Sensor with ½ NPT Conduit Entry Hot bearing WARNING device, for use in hazardous areas Installation guide PT100V3C Bearing Temperature Sensor With Grease nipple 1/2

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it. Electric Wall Oven Technical Information AEW3630DD*, AEW4630DD*, JJW8230DD* MEW5627DD*, MEW5630DD*, MEW6627DD*, MEW6630DD*, Refer to Service Manual 6022506 for detailed installation, operating, testing,

More information

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS CONTENTS SAC SERIES TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE 1. INSTALLATION 2. SPECIFICATIONS 2.1 GENERAL SPECIFICATIONS 2.2 MINIMUM PIECES, WEIGHT APPLIED & SAMPLE SIZE WEIGHT SPECIFICATIONS OPERATION

More information

A25 Series Warm Air Control with Manual Reset

A25 Series Warm Air Control with Manual Reset FANs 125, 121 Product/Technical Bulletin A25 Issue Date 0316 A25 Series Warm Air Control with Manual Reset The A25 Series Warm Air Control with Manual Reset is designed to shut down fans, burners, dampers,

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

Warnings and Safety Tips

Warnings and Safety Tips Warnings and Safety Tips The following safety tips are essentially important. Please strictly follow the manual s instructions in operation to guarantee safety. Improper operation or incorrect working

More information

P445 Series Electronic Lube Oil Control

P445 Series Electronic Lube Oil Control FANs 125, 121 s Section P Product/Technical Bulletin P445 Issue Date 0100 P445 Series Electronic Lube Oil The P445 Series Electronic Lube Oil is designed for use on refrigeration compressors equipped with

More information

An ISO 9001:2008 Registered Company

An ISO 9001:2008 Registered Company An ISO 9001:2008 Registered Company CVC501-A HVAC & Fast Idle CAN Vehicle Controller CVC502-A HVAC Control without Fast Idle 2011-2016 Ford F250-F550 (CVC501/502-A) 2017 Ford F-250-F550 (B-CVC501/502-A)

More information

CHIP. Reverse Osmosis System Controller Documentation

CHIP. Reverse Osmosis System Controller Documentation CHIP Reverse Osmosis System Controller Documentation Document Revised June, 2017. 2017 icontrols Technologies Inc icontrols Technologies Inc. 1821 Empire Industrial Court, Suite A Santa Rosa, CA 95403

More information

Electro Controls. Temperature Controllers WattsIndustries.co.uk

Electro Controls. Temperature Controllers WattsIndustries.co.uk Electro Controls Temperature Controllers - 2017 WattsIndustries.co.uk Temperature Controllers 0-1DC Section 03 TEMPERATURE CONTROLLERS 0-1DC PROPORTIONAL 1-2 STAGES ETC.. These products can monitor the

More information

DIFFERENTIAL THERMOSTAT

DIFFERENTIAL THERMOSTAT DIFFERENTIAL DSD-2 Differential Thermostat. This microcomputer based controller is capable of Testing and Controlling the Temperature Difference between Two remote locations. It reads the temperature from

More information

Eliwell Device Manager - Parameters Table [EL61.00.DAX] Author: m.deantoni Machine: GIND Date: 28/04/ :31. Model: ST54X.

Eliwell Device Manager - Parameters Table [EL61.00.DAX] Author: m.deantoni Machine: GIND Date: 28/04/ :31. Model: ST54X. Group Name: CF. 1 CF00 - Type of analogue input AI1 num 0 2 0 2 2 CF01 - Type of analogue input AI2 num 0 2 0 2 3 CF02 - Type of analogue input AI3 num 0 6 0 5 4 CF03 - Type of analogue input AI4 num 0

More information

WARNING User Responsibility

WARNING User Responsibility WARNING User Responsibility FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other

More information

AE R2 December CoreSense Diagnostics v2.11 for Copeland Discus Compressors AE R2. Table of Contents

AE R2 December CoreSense Diagnostics v2.11 for Copeland Discus Compressors AE R2. Table of Contents AE8-1368 R2 December 2012 CoreSense Diagnostics v2.11 for Copeland Discus Compressors Table of Contents 1.0 Overview 1.1 Functionality 1.1.1 Diagnostics 1.1.2 Communication 1.1.3 Fault History 1.2 Features

More information

TCS 1200 Portable Temperature Calibrator

TCS 1200 Portable Temperature Calibrator TCS 1200 Portable Temperature Calibrator Instruction Manual MM 2 CONTENTS DESCRIPTION EMC Information Electrical Safety Environmental Ratings Insert Warning Health & Safety Instructions Guarantee Cautionary

More information

G76x Direct Spark Ignition Controls

G76x Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G76x Issue Date 0400 G76x Direct Spark Ignition Controls Figure 1: G76x Direct Spark Ignition

More information

ROCKLEA TRUCK ELECTRICAL. Sleeper Air NXT. Owner s Manual. Revision th March 2013

ROCKLEA TRUCK ELECTRICAL. Sleeper Air NXT. Owner s Manual. Revision th March 2013 ROCKLEA TRUCK ELECTRICAL Sleeper Air NT Owner s Manual Revision 230 24 th March 2013 Rocklea Truck Electrical Rocklea Truck Electrical is Brisbane's premier truck lighting and custom accessory manufacturer

More information

Installation and Operation Manual Flo-Sense NH 3 Flow Indicator System

Installation and Operation Manual Flo-Sense NH 3 Flow Indicator System Installation and Operation Manual Flo-Sense NH 3 Flow Indicator System September 2013 Form FVC098 - Rev 02 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. 1. Contact with

More information