1 CATALOG: Distributions & Controls **Wolff Bros. Supply, Inc. reserves the right to substitute like products. Product information is subject to Manufacturer rolling changes and/or typographical errors.

2 Wolff Bros. Supply, Inc. Services Counter Hours Monday - Friday 7:00 a.m. to 5:00 p.m. Saturday 7:30 a.m :00 a.m. Closed Saturday except Wooster & Mansfield QUALITY WHOLESALE DISTRIBUTION Electrical, Lighting, DataCom, Plumbing, Kitchen & Bath Cabinetry, HVAC Equipment, Tools, Fasteners & Chemicals The First Choice Of Professionals! A business to business portal for Wolff Bros. Supply, Inc. customers. Technology Solutions WolffNet Online order & account access Communication Wyle's Specials Pricing Alerts Close-Out Specials Training Classes Akron Ashland Cleveland Elyria Findlay Mansfield Marion Medina Mentor Sandusky Toledo Wooster

3 Circuit Breakers Cutler-Hammer - Circuit Breakers Cutler-Hammer - Circuit Breaker Accessories Cutler Hammer Circuit Breaker Accessories We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers Circuit Breakers C-HBHLW1 C-HBHLW2 C-HBREQS125 C-HBRFP C-HBRHDK125 C-HBRHT C-HBRSF125 C-HCH125RB C-HCH9MB270 C-HCHFP C-HCHHT C-HCHLO C-HCHMLCS C-HCHPL C-HMCBK225 C-HQL1HT C-HQL1NPL C-HQL23NPL Used to secure handle in ON or OFF position for 1-Pole BR Circuit Bkrs. (handle mounted) Used to secure handle in ON or OFF position for 2 and 3-pole Type BR Circuit Bkrs (handle mounted) Hold-Down Screw Kit for 2 & 3-Pole Type BR Breakers Up To 125 Amp, For Use In 1-Phase & 3-Phase Main Lug Only Loadcenters. 1" Circuit Breaker Space Filler Plate for Type BR Breakers Hold-Down Screw Kit for 2 & 3-Pole Type BR Breakers in Amp, 1-Phase or 3-Phase Main Lug Only Loadcenters. Handle Tie, Molded Plastic Handle. Used w/ BR Type Circuit Breakers 125A, 2-Pole, BR Main or Sub-Feed Block, Two 1" Spaces Needed Hold-down Retainer Kit for 1, 2, 3-Pole CH Circuit Bkrs Mounting Base for 2-Pole Type CH Circuit Breaker - 70 Amp. Maximum Filler Plate, 3/4" space, for CH Circuit Breakers Handle Tie Bar for Physically Joining the Handles of 2 Adjacent 1-Pole Type CH Circuit Breakers, Molded Plastic Handle Cover Handle Lock for 1-Pole Type CH & CHQ Circuit Bkrs., Handle Mounted, Secures in ON or OFF Position - 5-Pk Mechanical Interlock Type CH for 2, 3, and 4-Pole Breakers, Clamshell Handle Lockoff, Padlockable,for Locking Handle of 1, 2 or 3-Pole type CH Circuit Bkrs., Escutcheon Mounted Load Side Lug Kit for BW and CSR Breakers 1-Pole Quicklag Handle Tie for QC Miniature Circuit Breakers 1-Pole Handle Lock, Quicklag Type P, B, & C Breakers 2 or 3-Pole Non-Padlockable Handle Lock for Quicklag Type P, B, & C Breakers Type BA - Miniature QUICKLAG Bolt-On Type BA Bolt-on Circuit Breakers Quicklag type BA 10,000 AIC, thermal-magnetic circuit breakers. 1-Pole, Bolt-on, requires one 1" space. 2-Pole Bolt-on, requires two 1" spaces. Listed UL489. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HBAB1015 C-HBAB1020 C-HBAB1030 C-HBAB2015 C-HBAB2020 C-HBAB2030 C-HBAB2040 C-HBAB2050 C-HBAB2060 C-HBAB2080 C-HBAB2100 C-HBAB3020H C-HBAB3030H C-HBAB3040H C-HBAB3050H 15A, 1-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 20A, 1-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 30A, 1-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 15A, 2-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 20A, 2-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 30A, 2-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 40A, 2-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 50A, 2-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 60A, 2-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 80A, 2-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 100A, 2-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 120/240VAC, 10,000 AIC 20A, 3-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 240 VAC, 10,000 AIC 30A, 3-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 240 VAC, 10,000 AIC 40A, 3-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 240 VAC, 10,000 AIC 50A, 3-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 240 VAC, 10,000 AIC Does Not Contain Clearance Items 1

4 Circuit Breakers Cutler-Hammer - Circuit Breakers Circuit Breakers Type BA - Miniature QUICKLAG Bolt-On C-HBAB3060H 60A, 3-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 240 VAC, 10,000 AIC C-HBAB3070H 70A, 3-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on, 240 VAC, 10,000 AIC C-HBAB3100H 100A, 3-Pole, Type BA QUICKLAG Industrial Circuit Breaker Bolt-on 240 VAC, 10,000 AIC Type BR - Plug-on Breakers Type BR Plug-on Circuit Breakers Plug-on type BR circuit breakers, 10,000 AIC. 1-Pole requires one 1" space. 2-Pole requires two 1" spaces. 3-Pole requires three 1" spaces. We stock authentic Eaton Cutler-Hammer Breakers Beware: The DANGER of Counterfeit Breakers C-HBR115 C-HBR120 C-HBR130 C-HBR2100CS C-HBR215 C-HBR220 C-HBR225 C-HBR230 C-HBR240 C-HBR250 C-HBR260 C-HBR270 C-HBR280 C-HBR290 C-HBR330 15A, 1-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #14-4, 10,000 AIC 20A, 1-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #14-4, 10,000 AIC 30A, 1-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #14-4, 10,000 AIC 100A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, #8-1/0, 10,000 AIC, Clam Shell 15A, 2-Pole, 120/240V, Type BR Plug-On Circuit Breaker, Wire Size #14-4, 10,000 AIC 20A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #14-4, 10,000 AIC 25A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #14-4, 10,000 AIC 30A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #14-4, 10,000 AIC 40A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #14-4, 10,000 AIC 50A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #14-4, 10,000 AIC 60A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #8-1/0, 10,000 AIC 70A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #8-1/0, 10,000 AIC 80A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #8-1/0, 10,000 AIC 90A, 2-Pole, 120/240V, Type BR Plug-on Circuit Breaker, Wire Size #8-1/0, 10,000 AIC 30A, 3-Pole, 240V, Type BR Plug-on Circuit Breaker, Wire Size #14-4, 10,000 AIC Type BR - Plug-on Non-CTL Duplex Bkr Type BR Duplex Non-CTL Plug-On Circuit Breakers Class Non-CTL, duplex plug-on replacement circuit breakers. Breakers do not have rejection tab feature. 1-Pole, requires 1" space. 120Vac. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HBR1515 C-HBR /15A, 1-Pole, Type BR Duplex Non-CTL Plug-on Circuit Breaker, 10,000 AIC 20/20A, 1-Pole, Type BR Duplex Non-CTL Plug-on Circuit Breaker, 10,000 AIC Does Not Contain Clearance Items 2

5 Circuit Breakers Cutler-Hammer - Circuit Breakers Type BR-CAF - Arc Fault Combination Eaton Cutler-Hammer BR Breakers Plug-On Combination Type ARC Fault Circuit Breakers, Type BR -- 10kA/C, 120 Vac and 120/240 Vac. A combination type arc fault circuit interrupter is a device that includes all of the protection offered by the branch feeder AFCI (mitigation of high current arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers Circuit Breakers C-HBRACAF115 C-HBRACAF120 C-HBRCAF115 C-HBRCAF115QN C-HBRCAF120 C-HBRCAF120QN 15 Amp, 1-Pole, Type BR Combination Fireguard/Arc Fault Circuit Interrupter, 10 kaic, 120/240 VAC. Includes: Diagnostic AFCI. 20 Amp, 1-Pole, Type BR Combination Fireguard/Arc Fault Circuit Interrupter, 10 kaic, 120/240 VAC. Includes: Diagnostic AFCI. 15 Amp, 1-Pole, Type BR Combination Fireguard/Arc Fault Circuit Interrupter, 10 kaic, 120/240 VAC. 15 Amp, 1-Pole, Type BR Combination Fireguard/Arc Fault Circuit Interrupter, 10 kaic, 120/240 VAC. Quick Connect Ready. 20 Amp, 1-Pole, Type BR Combination Fireguard/Arc Fault Circuit Interrupter, 10 kaic, 120/240 VAC. 20 Amp, 1-Pole, Type BR Combination Fireguard/Arc Fault Circuit Interrupter, 10 kaic, 120/240 VAC. Quick Connect Ready. Type BR-LAFG -Arc Fault/Ground Comob C-HBRLAFGF115 C-HBRLAFGF120 Eaton Cutler-Hammer Type BR Dual purpose AF/GF Arc fault/ground fault circuit interrupter Eaton is expanding its line of arc fault and ground fault solutions to include the dual purpose arc fault/ground fault (AF/GF) circuit interrupter for residential and light commercial applications. The AF/GF circuit interrupter was developed in response to the 2014 National Electrical Code (NECT) that now requires AFCI protection in kitchens and laundry areas as well as the historical requirement of ground fault protection. Eaton s AF/GF circuit interrupter will offer both types of protection in one familiar package.the AF/GF circuit interrupter provides quick installation and a single location to easily access and identify tripped circuits. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers Type CCV - Main Breakers 15 Amp, 1-Pole, Type BR Combination Arc Fault/Ground Fault, 10 kaic, 120/240 VAC. 20 Amp, 1-Pole, Type BR Combination Arc Fault/Ground Fault, 10 kaic, 120/240 VAC. Type CCV Main Circuit Breaker 120/240 VAC 2-Pole CCV main tenant circuit breaker. Bolt-on type. 10,000 AIC. We stock authentic Eaton Cutler- Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCCV2200 Type CH - Arc Fault Plug-On Breaker 200A, 120/240V, 2-Pole Type CCV Main Breaker, Wire Size #2/0-300 kcmil, 10,000 AIC Type CH-AF Fire-Guard AFCI Circuit Breakers Plug-on branch feeder type arc fault circuit breakers. 1-Pole requires 3/4" space. Provides protection from fires caused by arcing faults. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCH120AF 20A, 1-Pole, Type CH Fire-Guard AFCI Circuit Breaker, 10,000 AIC Does Not Contain Clearance Items 3

6 Circuit Breakers Cutler-Hammer - Circuit Breakers Circuit Breakers Type CH - Plug-On Breakers Type CH Plug-on Circuit Breakers Plug-on CH circuit breakers have a quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip free handle design. Breakers trip to the OFF position, elminating nuisance callbacks. Handles are maked with ON-OFF indication and ampere rating of the breaker. 1-Pole 120/240 Vac requires one 3/4" space. 2-Pole 120/240 Vac common trip requires two 3/4" spaces. 3-Pole 240 Vac common trip requires three 3/4" spaces. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCH125 C-HCH2100 C-HCH2125 C-HCH2150 C-HCH260 C-HCH270 C-HCH280 C-HCH290 C-HCH3080 C-HCH3100 C-HCH315 C-HCH320 C-HCH330 C-HCH340 C-HCH350 C-HCH360 C-HCH370 Type CHF - Breaker w/trip Flag 25A, 1-Pole, Type CH Circuit Breaker, 120/240V, 10,000 AIC 100A, 2-Pole, Type CH Circuit Breaker, 120/240V, 10,000 AIC 125A, 2-Pole, Type CH Circuit Breaker, 120/240V, 10,000 AIC 150A, 2-Pole, Type CH Circuit Breaker, 10,000 AIC, 120/240V, for use in Single Phase Panels Only 60A, 2-Pole, Type CH Circuit Breaker, 120/240V, 10,000 AIC 70A, 2-Pole, Type CH Circuit Breaker, 120/240V, 10,000 AIC 80A, 2-Pole, Type CH Circuit Breaker, 120/240V, 10,000 AIC 90A, 2-Pole, Type CH Circuit Breaker, 120/240V, 10,000 AIC 80A, 3-Pole, Type CH Circuit Breaker, 240V, 10,000 AIC 100A, 3-Pole, Type CH Circuit Breaker, 240V, 10,000 AIC 15A, 3-Pole, Type CH Circuit Breaker, 240V, 10,000 AIC 20A, 3-Pole, Type CH Circuit Breaker, 240V, 10,000 AIC 30A, 3-Pole, Type CH Circuit Breaker, 240V, 10,000 AIC 40A, 3-Pole, Type CH Circuit Breaker, 240V, 10,000 AIC 50A, 3-Pole, Type CH Circuit Breaker, 240V, 10,000 AIC 60A, 3-Pole, Type CH Circuit Breaker, 240V, 10,000 AIC 70A, 3-Pole, Type CH Circuit Breaker, 240V, 10,000 AIC Type CHF Circuit Breaker with Trip Flag Flag visually confirms "Tripped" status making it easy for the homeowner to identify. Exclusive "Trip to OFF" and simple 1- Step Breaker Reset feature eliminates the need to turn the breaker off before turning to the ON position. Tri-Drive Screw Accepts Flat, Robertson or Phillips Drivers, making it easier for electricians to install. Space Saving 3/4" Design Accommodates more breakers per panel. Limited Lifetime Warranty. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCHF115 C-HCHF120 C-HCHF125 C-HCHF130 C-HCHF215 C-HCHF220 C-HCHF225 C-HCHF230 C-HCHF235 C-HCHF240 C-HCHF250 15A, 1-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 20A, 1-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 25A, 1-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 30A, 1-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 15A, 2-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 20A, 2-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 25A, 2-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 30A, 2-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 35A, 2-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 40A, 2-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC 50A, 2-Pole, Type CH Circuit Breaker with Trip Indication, 120/240 VAC, 10,000 AIC Does Not Contain Clearance Items 4

7 Circuit Breakers Cutler-Hammer - Circuit Breakers Type CHF-AFCI - GFCI Circuit Breakers Type CH Circuit Breakers Type CH AFCI Single-Pole Circuit Breaker. Dual Purpose Arc Fault/Ground Fault 3/4-inch (19.1 mm) Wide Circuit Breakers, Type CH, 120 Vac - 10kAIC. AF/GF Single-Pole Circuit Breaker. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers Circuit Breakers C-HCHFAFGF120 C-HCHFAFGF120PN C-HCHFCAF115 C-HCHFCAF115PN C-HCHFCAF120 C-HCHFCAF120PN 20A 1-Pole Combination Arc Fault/Ground Fault 3/4" Wide Circuit Breaker, 10,000 AIC 20A Single-pole, plug-on neutral 10kA/C Dual AFCI GFCI 15A, 1-Pole, Type CH Circuit Bkr, Combo Arc Fault Circuit Interrupter, 10,000 AIC 15A 1 pole, AFCI plug-on neutral 10k AIC, Combo Arc Fault and Ground Fault 20A, 1-Pole, Type CH Circuit Bkr, Combo Arc Fault Circuit Interrupter, 10,000 AIC 20A AFCI Plug-on Neutral Single-pole 10kA/C combo Circuit Breaker Type CH-FGFT - Arc & Ground Fault Circuit Breaker Eaton Cutler-Hammer Type CH CHF Circuit Breakers Arc Fault and Ground Fault Breakers (AFCI/GFCI) Residential loadcenters and meter breaker panels. Light commercial distribution panels. Pool panels. Residential transfer swich panels. Various OEM applications. Mechanical flag for trip indication. Exclusive "Tip to OFF" and simple 1-Step breaker reset. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCHFGFT115 C-HCHFGFT120 C-HCHFGFT120PN C-HCHFGFT Amp, 1-Pole, Type CH Ground Fault Circuit Breaker, 10 kaic, 120 VAC. Includes: Trip Indication, Self-Testing. 20 Amp, 1-Pole, Type CH Ground Fault Circuit Breaker, 10 kaic, 120 VAC. Includes: Trip Indication With Self Test 20 Amp, 1-Pole, Type CH Ground Fault Circuit Breaker, Plug on Neutral, 10 kaic, 120 VAC. Includes: Trip Indication With Self Test 30 Amp, 1-Pole, Type CH Ground Fault Circuit Breaker, 10 kaic, 120 VAC. Includes: Trip Indication With Self Test Type CH-GFI - Plug-On Breaker Type CH-GF Plug-on GFI Circuit Breaker Plug-on ground fault circuit breakers (5 milliampere). 1-pole 120 Vac requires 3/4" space, 2-pole 120/240 Vac common trip requires two 3/4" spaces. 10,000 AIC. 1-pole type CHGFIs are designed for use in two-wire, 120 Vac circuits. 2-pole type CHGFIs are designed for use in three-wire, 120/240 Vac circuits, 120 Vac multiwire circuits employing common, neutral and two-wire, 240 Vac circuits obtained from a 120/240 Vac source. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCH240GF C-HCH260GF 40A, 2-Pole, Type CH Ground Fault Circuit Breaker, 10,000 AIC 60A, 2-Pole, Type CH Ground Fault Circuit Breaker, 10,000 AIC Does Not Contain Clearance Items 5

8 Circuit Breakers Cutler-Hammer - Circuit Breakers Circuit Breakers Type CH-GFI - Self-Test Plug-On Breakers Eaton Cutler-Hammer Type CH Ground Fault Breakers - CH-GFT Plug-On ground fault circuit breakers. Type CH, 10 kaic. Self-test. Two-Pole 120/240 Vac Common Trip. Requires Two 3/4" spaces. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCH220GFT C-HCH230GFT C-HCH250GFT Type CHT - Tandem Breakers 20A, 2-Pole, Type CH Ground Fault Plug-On Breaker with Self Test, 10,000 AIC 30A, 2-Pole, Type CH Ground Fault Plug-On Breaker with Self Test, 10,000 AIC 50A, 2-Pole, Type CH Ground Fault Plug-On Breaker with Self Test, 10,000 AIC Type CHT Plug On Tandem Circuit Breakers 1-Pole, Plug-on, Requires one 3/4" Space. Voltage Rating: 120/240 Vac. 10,000 AIC. All circuit breakers have rejection feature. HACR rated. Switching duty rated. Use only with loadcenters marked for use with CHT breakers. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCHT1515 C-HCHT2020 Type CL - Classified Circuit Breakers (2) 15A, 1 Pole, Tandem Circuit Breaker, 10,000 AIC (2) 20A, 1 Pole, Tandem Circuit Breaker, 10,000 AIC Cutler-Hammer Type CL Classified Circuit Breakers Type CL replacement breakers for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE/Siemens Loadcenters Classified as direct replacements by Underwriters Laboratories. 120/240 Vac. Single-pole requires one 1" space. Two-pole requires two 1" spaces. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCL115 C-HCL120 C-HCL215 C-HCL220 C-HCL230 C-HCL240 C-HCL250 15A, 1-Pole, Type CL Classified Plug-On Breaker, Wire Size #14-4, 10,000 AIC 20A, 1-Pole, Type CL Classified Plug-On Breaker, Wire Size #14-4, 10,000 AIC 15A, 2-Pole, Type CL Classified Plug-On Breaker, Wire Size #14-4, 10,000 AIC 20A, 2-Pole, Type CL Classified Plug-On Breaker, Wire Size #14-4, 10,000 AIC 30A, 2-Pole, Type CL Classified Plug-On Breaker, Wire Size #14-4, 10,000 AIC 40A, 2-Pole, Type CL Classified Plug-On Breaker, Wire Size #14-4, 10,000 AIC 50A, 2-Pole, Type CL Classified Plug-On Breaker, Wire Size #14-4, 10,000 AIC Type CL-GF - Classified Circuit Breakers Cutler-Hammer Type CL-GF Classified Arc Fault Circuit Breakers Type CL-GF replacement breakers for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE/Siemens Loadcenters Classified as direct replacements by Underwriters Laboratories. 120/240 Vac. Single-pole requires one 1" space.two-pole requires two 1" spaces. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HCL120GFT 20A, 1-Pole, Type CL Ground Fault Circuit Breaker, Self Test w/ Trip Indication, Plug-On, 10,000 AIC Does Not Contain Clearance Items 6

9 Circuit Breakers Cutler-Hammer - Circuit Breakers Type CSR - Main Circuit Breakers Cutler-Hammer Type CSR Main Circuit Breakers Type CSR CH main circuit breakers protect the entire loadcenter. It can also be used as a service disconnect. For use in type ECB unit enclosures. Plug-on, 120/240 VAC; 25,000 AIC. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers Circuit Breakers C-HCSR2150N C-HCSR2200N C-HCSR2225N 150A, 2-Pole, Type CSR Main Circuit Breaker, Wire Size #2-300kcmil, 25,000 AIC 200A, 2-Pole, Type CSR Main Circuit Breaker, Wire Size #2-300kcmil, 25,000 AIC 225A, 2-Pole, Type CSR Main Circuit Breaker, Wire Size #2-300kcmil, 25,000 AIC Type GFTCB - GFI Self-Test Plug-On Breakers Cutler-Hammer GFTCB GFCI Self-Test Circuit Breakers Type BR plug-in ground fault circuit breaker. Automatically senses hot wire-to-ground faults and shuts off the power. Automonitoring function provides periodic automatic testing of GFCI. If the self-test detects that GFCI protection might be compromised it indicates an alert. Each pole is a 1" space. 10 kaic. C-HGFTCB115 C-HGFTCB120 15A, 1-Pole, 120V, Type GFTCB Ground Fault Circuit Breaker, Self-Test, Plug-On, 10,000 AIC 20A, 1-Pole, 120V, Type GFTCB Ground Fault Circuit Breaker, Self-Test, Plug-On, 10,000 AIC Type GHB - Bolt-On Thermal Magnetic Breakers Type GHB Bolt-on Panelboard Circuit Breakers Series C molded case thermal-magnetic bolt-on circuit breakers with non-interchangeable trip units. UL/CSA listed. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HGHB1015 C-HGHB1020 C-HGHB1030 C-HGHB2020 C-HGHB2030 C-HGHB2050 C-HGHB3015 C-HGHB3020 C-HGHB3030 C-HGHB3040 C-HGHB3050 C-HGHB A, 1-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 20A, 1-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 30A, 1-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 20A, 2-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 30A, 2-Pole,Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 50A, 2-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 15A, 3-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 20A, 3-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 30A, 3-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 40A, 3-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 50A, 3-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 60A, 3-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC Does Not Contain Clearance Items 7

10 Circuit Breakers Cutler-Hammer - Circuit Breakers Circuit Breakers Type GHB - Bolt-On Thermal Magnetic Breakers C-HGHB3070 C-HGHB3080 C-HGHB A, 3-Pole,Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 80A, 3-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC 100A, 3-Pole, Type G - GHB, Thermal Magnetic, Bolt-On, Molded Case Circuit Breaker, Non-Interchangeable Trip Units, 277/480V, 14,000 AIC Type QBGF - QUICKLAG Circuit Breaker Cutler-Hammer Branch Breakers - QBGF Quicklag Type QBGF ground fault, thermal-magnetic, circuit breakers. Class A GFCI. Bolt-On Mounting. 10,000 AIC Rating. 5mA Trip Sensitivity. For use in panel type PRL1A. UL 489 Listed. We stock authentic Eaton Cutler-Hammer Breakers. Beware: The DANGER of Counterfeit Breakers C-HQBGFT Amp, 1-Pole, Type QBGF, Quicklag, Miniature Industrial Ground Fault Circuit Breaker, Self Test, Bolt-on, 120 VAC, 10 kaic. Federal Pacific - Circuit Breakers Type NA Stab-In Breakers - FED Type NA Circuit Breakers - FED Plug-in. 120/240VAC. 10,000 AIC. 1-Pole Requires One 1" space, SWD rated. 2-Pole Requires Two 1" spaces, HACR rated. We stock authentic Federal Pacific Breakers. Beware: The DANGER of Counterfeit Breakers FED15 FED20 FED220 FED240FEDPIO FED250FEDPIO FED2P60FEDPIO 15A, 1-Pole, Type NA Stab-In Breaker, Black Handle 20A, 1-Pole, Type NA Stab-In Breaker, Black Handle 20A, 2-Pole Type NA Stab-In Breaker, Black Handle 40A, 2-Pole, Type NA Stab-In Breaker, Black Handle 50A, 2-Pole, Type NA Stab-In Breaker, Black Handle 60A, 2-Pole Type NA Stab-In Breaker, Black Handle Type NC Tandem Stab-In Breakers - FED Type NC Tandem Circuit Breakers - FED Plug-in. 120/240VAC. 10,000 AIC. 1-Pole: Requires 1/2 of 1" space, SWD Rated. 2-Pole: requires One 1" space, HACR Rated. We stock authentic Federal Pacific Breakers. Beware: The DANGER of Counterfeit Breakers FED015 FED020FEDPIO FED0230FEDPIO 15A, 1-Pole Type NC Tandem Stab-In Breaker, Requires 1/2 of One 1" Space 20A, 1-Pole Type NC Tandem Stab-In Breaker, Requires 1/2 of One 1" Space 30A, 2-Pole Type NC Tandem Stab-In Breaker, Requires One 1" Space Does Not Contain Clearance Items 8

11 Circuit Breakers General Electric - Circuit Breakers Type THQB Mini Bolt-On Breaker THQB Circuit Breakers Q-Line Series bolt-on, molded case, miniature circuit breakers. 120/240 Vac. 10,000 AIC. We stock authentic General Elecrtic Breakers. Beware: The DANGER of Counterfeit Breakers Circuit Breakers GEBTHQB1120 GEBTHQB21100 GEBTHQB2120 GEBTHQB2130 GEBTHQB2140 GEBTHQB2150 GEBTHQB2160 GEBTHQB32020 GEBTHQB32030 GEBTHQB32040 GEBTHQB32050 GEBTHQB32060 Type THQL Plug-In Breaker - GEB 20A 1-Pole Bolt-on Mini Circuit Breaker 100A 2-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 20A 2-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 30A 2-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 40A 2-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 50A 2-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 60A 2-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 20A 3-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 30A 3-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 40A 3-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 50A 3-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip 60A 3-Pole Bolt-on Mini Circuit Breaker, Internal Common Trip Type THQL Molded Case Circuit Breakers - GEB Thick Series 1" Module. 120/240 VAC. 10,000 AIC. 1-Pole Requires one 1" space, HACR rated. 2-Pole Requires two 1" spaces, incorporates internal common trip bar, HACR rated. We stock authentic General Elecrtic Breakers. Beware: The DANGER of Counterfeit Breakers GEBTHQL1115 GEBTHQL1120 GEBTHQL21100 GEBTHQL2120 GEBTHQL2130 GEBTHQL2140 GEBTHQL2150 GEBTHQL2160 Type THQP Half Size Breaker - GEB 15A, 1 Pole, 1" Wide Type THQL Plug-In Breaker, UL listed SWD 20A, 1 Pole, 1" Wide Type THQL Plug-In Breaker, UL listed SWD 100A, 2 Pole, 2" Wide Type THQL Plug-In Breaker 20A, 2 Pole, 2" Wide Type THQL Plug-In Breaker 30A, 2 Pole, 2" Wide Type THQL Plug-In Breaker 40A, 2 Pole, 2" Wide Type THQL Plug-In Breaker 50A, 2 Pole, 2" Wide Type THQL Plug-In Breaker 60A, 2 Pole, 2" Wide Type THQL Plug-In Breaker Type THQP Molded Case Circuit Breakers Thin Series 1/2" Module. 120/240 VAC. 10,000 AIC. 1-Pole Requires 1/2" of one 1" space, HACR rated. 2-Pole Requires one 1" space, HACR rated. We stock authentic General Elecrtic Breakers. Beware: The DANGER of Counterfeit Breakers GEBTHQP115 GEBTHQP120 GEBTHQP220 GEBTHQP230 GEBTHQP240 15A 1 Pole, 1/2" Wide Type THQP Plug-In Breaker, UL listed SWD 20A 1 Pole, 1/2" Wide Type THQP Plug-In Breaker, UL listed SWD 20A 2 Pole 1" Wide Type THQP Plug-In Breaker 30A 2 Pole 1" Wide Type THQP Plug-In Breaker 40A 2 Pole 1" Wide Type THQP Plug-In Breaker Does Not Contain Clearance Items 9

12 Circuit Breakers General Electric - Circuit Breakers Type THQP Half Size Breaker - GEB Circuit Breakers GEBTHQP250 Murray - Circuit Breakers 50A 2 Pole 1" Wide Type THQP Plug-In Breaker Type MH-T Duplex Breakers - MUR MP Type MH-T Duplex Circuit Breakers - MURMPx Duplex (2) in 1-Pole Circuit Breakers. Requires 1" space. 10,000 AIC. 120 VAC. Wire range: #14 - #8 Cu, #12 - #8 Al. These space saver duplex breakers combine two independent 1/2" breaker poles in a common unit. Unit plugs into one load center stab and requires one panel space. HACR rated. We stock authentic Murray Breakers. Beware: The DANGER of Counterfeit Breakers MURMP1515 MURMP1515N MURMP2020 MURMP2020N Type MP GFI Breaker - MUR 15A-15A, 1 Pole Plug-In Duplex Circuit Breaker, Type MH-T 15A-15A, 1 Pole Plug-In Duplex Circuit Breaker, Type MH-T, Non-CTL 20A-20A, 1 Pole Plug-In Duplex Circuit Breaker, Type MH-T 20A-20A, 1 Pole Plug-In Duplex Circuit Breaker, Type MH-T, Non-CTL MP GFCI Circuit Breaker - MURMP120GFA 20A, 1-Pole Ground-Fault Circuit Interrupter (Class A - 5mA). 120 VAC. Standard 1" per Pole format with plug-in design. HACR rated. UL listed as SWD (switching duty) rated, suitable for 120V AC fluorescent lighting. Will de-energize the circuit when a fault current to ground is 6 millamperes or more. White line neutral (pigtail) must be connected to the panel neutral for the device to function. We stock authentic Murray Breakers. Beware: The DANGER of Counterfeit Breakers MURMP120GFA Type MP-D 4-Space Breakers - MUR 20A 1-Pole Plug-In Type GFCI Circuit Breaker, Self-Test, 10kA MP-D 4-Space Circuit Breaker - MURMPD2200 Plug-on 200A, 2-pole, circuit breaker. Full size, 1" per pole. Requires 4 panel spaces, 2 adjacent and 2 opposite. 120/240VAC common trip. 10,000 AIC. Wire range #4-300 kcmil Cu/Al. UL type MD-T. We stock authentic Murray Breakers. Beware: The DANGER of Counterfeit Breakers MURMPD2200 Type MP-T Full Size Breakers - MUR 200A 2-Pole 4-Space (2 adjacent & 2 opposite) Plug-In Type Full Size Circuit Breaker MP-T Full Size Circuit Breakers - MUR Full size 1" per Pole circuit breaker with insta-wire. 10,000 AIC. UL listed for use with 60/75 wire through 125 amps HACR rated 120V AC Fluorescent Lighting. 1-Pole Plug-in requires 1" space, 120 VAC. 2-Pole Plug-in requires two 1" spaces, 120/240VAC. We stock authentic Murray Breakers. Beware: The DANGER of Counterfeit Breakers MURMP115 MURMP120 MURMP2100 MURMP220 MURMP230 15A 1-Pole Plug-In Type Full Size Circuit Breaker, UL listed SWD 20A 1-Pole Plug-In Type Full Size Circuit Breaker, UL listed SWD 100A 2-Pole Plug-In Type Full Size Circuit Breaker 20A 2-Pole Plug-In Type Full Size Circuit Breaker 30A 2-Pole Plug-In Type Full Size Circuit Breaker Does Not Contain Clearance Items 10

13 Circuit Breakers Murray - Circuit Breakers Type MP-T Full Size Breakers - MUR MURMP240 MURMP250 MURMP260 40A 2-Pole Plug-In Type Full Size Circuit Breaker 50A 2-Pole Plug-In Type Full Size Circuit Breaker 60A 2-Pole Plug-In Type Full Size Circuit Breaker Siemens Type QF GFI Breakers WBS Circuit Breakers Siemens Type QF GFI Breakers Type QF GFI Circuit BreakersPlug-in ground fault circuit interrupter breakers. 1-Pole requires one 1" space. 2-Pole requires two 1" spaces. 10,000 AIC. HACR rated. UL Listed and CSA Certified as Class A devices. We stock authentic Siemens Brakers. SIEQF115A Siemens Type QT Tandem Breakers 15A, 120VAC, 1 Pole, 1 Phase, I-T-E Molded Case GFI Breaker, Plug-in, Self Tested Type QT Tandem Circuit Breaker - SIEQx QT dual circuit breakers are 1" wide and consist of (2) 1-pole breakers. Plug-in style. Rated HACR. 120/240VAC. 15A & 20A are SWD Rated. 10,000 AIC. NC denotes No Clip; for use in older load centers. We stock authentic Siemens Brakers SIEQ2020NC 20A-20A 1-Pole, I-T-E Molded Case Tandem Breaker, Plug-in, No Clip Siemens/ITE - Circuit Breakers Siemens - Filler Plate - QF3 QF3 Filler Plate - SIEQF3 1" Filler Plate. For use with all 1" QP, BL, BQD, ED frame provisions. We stock authentic Siemens Breakers. Beware: The DANGER of Counterfeit Breakers SIEQF3 1" Filler Plate Siemens - Handle Blocking Device - QL1 QL1 Handle Blocking Device - SIEQL1 For holding breaker in "ON" or "OFF" position. 1, 2, or 3 Pole. Not a lockout/tagout device. For use with Breaker Frames BL, BLH, HBL, BQXD, BQ, BQH, HBQ. We stock authentic Siemens Breakers. Beware: The DANGER of Counterfeit Breakers SIEQL1 Handle Blocking Lock off Device Does Not Contain Clearance Items 11

14 Circuit Breakers Siemens/ITE - Circuit Breakers Siemens - Handle Tie - QTH3 Circuit Breakers QTH3 Handle Tie - SIEQTH3 Provides simultaneous switching of 2 adjacent handles. Does not provide common trip. For use with breaker frames BQ, QP, BQH, HBQ, B6x BLH, HBL. We stock authentic Siemens Breakers. Beware: The DANGER of Counterfeit Breakers SIEQTH3 Siemens - Lug Kit - TA1Q300 Handle Tie, Provides Simultaneous Switching Siemens Lug Kit Lugs for 60A to 225A QJ molded case circuit breakers. Lug body: Al. Lug wire range: (1) #6-300 kcmil Cu - (1) #4-300 kcmil Al. We stock authentic Siemens Breakers. Beware: The DANGER of Counterfeit Breakers SIETA1Q300 Lug Kit for 60A to 225A QJ Breakers Siemens Type AFCI Q120 Combo Breakers Siemens Type AFCI Q Combination Breakers 1-Pole. Plug-In. Arc Fault Circuit Interrupter. Combination Breaker. We stock authentic Siemens Brakers SIEQ120AFC Siemens Type B Bolt-On Breakers 20A 1-Pole, Plug-In, AFCI Combo Breaker BL Molded Case Circuit Breakers - SIEBx Panelboard mounting circuit breakers. 1" space per pole. Type BL - low tab bolt-on. 10,000 AIC. HCAR rated. We stock authentic Siemens Breakers SIEB120 SIEB2100 SIEB220 SIEB230 SIEB240 SIEB250 SIEB320 SIEB330 SIEB340 SIEB350 20A 1-Pole, 120/240V, I-T-E Molded Case Breaker, Bolt-On 100A 2-Pole, 120/240V common trip, I-T-E Molded Case Breaker, Bolt-On 20A 2-Pole, 120/240V common trip, I-T-E Molded Case Breaker, Bolt-On 30A 2-Pole, 120/240V common trip, I-T-E Molded Case Breaker, Bolt-On 40A 2-Pole, 120/240V common trip, I-T-E Molded Case Breaker, Bolt-On 50A 2-Pole, 120/240V common trip, I-T-E Molded Case Breaker, Bolt-On 20A 3-Pole, 240V common trip, I-T-E Molded Case Breaker, Bolt-On 30A 3-Pole, 240V common trip, I-T-E Molded Case Breaker, Bolt-On 40A 3-Pole, 240V common trip, I-T-E Molded Case Breaker, Bolt-On 50A 3-Pole, 240V common trip, I-T-E Molded Case Breaker, Bolt-On Does Not Contain Clearance Items 12

15 Circuit Breakers Siemens/ITE - Circuit Breakers Siemens Type BQ Plug-in Breakers Type BQ Circuit Breakers - SIEBQx Plug-In molded case circuit breakers. Lug-in/Lug-out with insta-wire. Breakers are supplied with load side lugs. Calibrated for 40 C maxium ambient application. We stock authentic Seimens Breakers Circuit Breakers SIEBQ1B020 Siemens Type P Bolt-On Breakers 20A, 1-Pole, 120VAC, Plug-In, Type BQ Molded Case Breaker, 10,000 AIR Type P Pushmatic Circuit Breakers - SIEPx Bolt-in Circuit Breakers.Thermal Magnetic. 1-Pole, 2-Poles or Duplex. HACR & SWD Rated. 1-Pole Voltage Rating: Poles Voltage Rating: 120/240. Duplex Voltage Rating: 120. We stock authentic Siemens Brakers SIEP130 SIEP2020 SIEP A, 1-Pole Bolt-On, I-T-E Molded Case Breakers 20-20A, Duplex, TWIN Pole Bolt-On, I-T-E Molded Case Breakers 100A, 2-Pole Bolt-On, I-T-E Molded Case Breakers Siemens Type QA Combo AFCI Breakers Type QA Combination Type AFCI Circuit Breakers Detects all three possible types of arc faults: line-to-ground, line-to, neutral and series. Plug-In. LED trip indicator. AFCI's detect arcing faults that standard circuit breakers are unable to detect. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arc-fault is detected. UL listed. We stock authentic Siemens Brakers SIEQA115AFC SIEQA120AFC Siemens Type QF GFI Breakers 15A 1-Pole, 120VAC, Type AFCI Combination Arc-Fault Breakers, Plug-In, 10,000 AIR 20A 1-Pole, 120VAC, Type AFCI Combination Arc-Fault Breakers, Plug-In, 10,000 AIR Type QF GFI Circuit Breakers - SIEQFx Plug-in ground fault circuit interrupter breakers. 1-Pole requires one 1" space. 2-Pole requires two 1" spaces. 10,000 AIC. HACR rated. UL Listed and CSA Certified as Class A devices. We stock authentic Siemens Brakers SIEQF115 SIEQF120A SIEQF250 15A 1-Pole, 120VAC, I-T-E Molded Case GFI Breaker, Plug-in 20A, 120VAC, 1 Pole, 1 Phase, I-T-E Molded Case GFI Breaker, Plug-in, Self Tested 50A, 120/240VAC, 2 Phase, I-T-E Molded Case GFI Breaker, Plug-in, Self Tested Does Not Contain Clearance Items 13

16 Circuit Breakers Siemens/ITE - Circuit Breakers Siemens Type QJ Bolt-On Breakers Circuit Breakers QJ Molded Case Circuit Breakers - SIEQJx QJ 225A frame molded case circuit breakers. 2 or 3-Pole, 240V AC. Load side TA1Q300 lugs are mounted and included when circuit breaker is ordered. We stock authentic Siemens Brakers SIEQJ22B200 Siemens Type QP Plug-In Breakers 200A, 2-Pole, I-T-E Molded Case Circuit Breaker Type QP Circuit Breakers - SIEQx Plug-in Circuit Breakers. 10,000 AIC. 1-Pole requires 1" space, 120/240VAC, HACR & SWD Rated. 2-Pole requires two 1" spaces, 120/240VAC, rated HACR. 3-Pole requires three 1" spaces, 240VAC, rated HACR. We stock authentic Siemens Brakers SIEQ115 SIEQ120 SIEQ130 SIEQ2100 SIEQ215 SIEQ220 SIEQ225 SIEQ230 SIEQ240 SIEQ250 SIEQ260 SIEQ270 SIEQ3100 SIEQ320 SIEQ330 SIEQ340 SIEQ350 SIEQ360 Siemens Type QT Tandem Breakers 15A, 1 Pole Plug-in, I-T-E Molded Case Breakers 20A, 1 Pole Plug-in, I-T-E Molded Case Breakers 30A, 1 Pole Plug-in, I-T-E Molded Case Breakers 100A, 2 Pole Plug-in, I-T-E Molded Case Breakers 15A, 2 Pole Plug-in, I-T-E Molded Case Breakers 20A, 2 Pole Plug-in, I-T-E Molded Case Breakers 25A, 2 Pole Plug-in, I-T-E Molded Case Breakers 30A, 2 Pole Plug-in, I-T-E Molded Case Breakers 40A, 2 Pole Plug-in, I-T-E Molded Case Breakers 50A, 2 Pole Plug-in, I-T-E Molded Case Breakers 60A, 2 Pole Plug-in, I-T-E Molded Case Breakers 70A, 2 Pole Plug-in, I-T-E Molded Case Breakers 100A, 3 Pole Plug-in, I-T-E Molded Case Breakers 20A, 3 Pole Plug-in, I-T-E Molded Case Breakers 30A, 3 Pole Plug-in, I-T-E Molded Case Breakers 40A, 3 Pole Plug-in, I-T-E Molded Case Breakers 50A, 3 Pole Plug-in, I-T-E Molded Case Breakers 60A, 3 Pole Plug-in, I-T-E Molded Case Breakers Type QT Tandem Circuit Breaker - SIEQx QT dual circuit breakers are 1" wide and consist of (2) 1-pole breakers. Plug-in style. Rated HACR. 120/240VAC. 15A & 20A are SWD Rated. 10,000 AIC. NC denotes No Clip; for use in older load centers. We stock authentic Siemens Brakers SIEQ1515 SIEQ A-15A 1-Pole, I-T-E Molded Case Tandem Breaker, Plug-in 20A-20A 1-Pole, I-T-E Molded Case Tandem Breaker, Plug-in Does Not Contain Clearance Items 14

17 Circuit Breakers Square D - Circuit Breakers Circuit Breakers for I-Line Panelboards Square D - Type FA, 480V, 3P, F-Frame Breakers QOFA34 Square D - FA Circuit Breakers The FA Molded Case, standard interrupting, thermal magnetic circuit breakers are for I-Line Panelboards and Switchboards Class 650, 651. F-frame, three pole, thermal-magnetic, 480Vac, 250 Vdc. Circuit Breakers QOFA34015 QOFA34020 QOFA34030 QOFA34060 QOFA34070 QOFA A 3-Pole, 480V F-Frame Breaker - Trip Setting: 275 Hold 600 Trip 20A 3-Pole, 480V F-Frame Breaker - Trip Setting: 275 Hold 600 Trip 30A 3-Pole, 480V F-Frame Breaker - Trip Setting: 275 Hold 600 Trip 60A 3-Pole, 480V F-Frame Breaker - Trip Setting: 800 Hold 1450 Trip 70A 3-Pole, 480V F-Frame Breaker - Trip Setting: 800 Hold 1450 Trip 100A 3-Pole, 480V F-Frame Breaker - Trip Setting: 900 Hold 1700 Trip Square D - Type FY, 277V, 1P, F-Frame Breakers QOFY14020 Square D - FY Circuit Breakers The FY Molded Case, Standard Interrupting, Circuit Breakers are for I-Line Panelboards and Switchboards Class 650, 651. F-frame, 20 Amp, 1-pole, 277Vac, 125Vdc., thermal-magnetic. Trip setting: 275 Hold, 600 Trip. Phase connection A, B or C. QOFY14020A QOFY14020B QOFY14020C 20A, 1-Pole, 277V, Phase Conn. A, F-Frame I-Line Circuit Breaker 20A, 1-Pole, 277V, Phase Conn. B, F-Frame I-Line Circuit Breaker 20A, 1-Pole, 277V, Phase Conn. C, F-Frame I-Line Circuit Breaker Square D - Type HDA, 600V, 3P, H-Frame Breakers QOHDA36 Square D - HDA Circuit Breakers H-frame Circuit Breakers for I-Line Panelboards and Switchboards. Class 612, D Interrupting, 3-pole, 600 Vac 50/60Hz. 4.5" Mounting Ht. H-frame 150A Standard Rated Thermal Magnetic (600 Vac) with Factory Sealed Trip Units. Terminal Wire Range AL150HD #14-#3/0 AWG Al or Cu. QOHDA36060 QOHDA36100 QOHDA36125 QOHDA A, 3-Pole, 600 Vac, HDA I-Line Breaker - Trip Setting: 800 Hold 1450 Trip 100A, 3-Pole, 600 Vac, HDA I-Line Breaker - Trip Setting: 900 Hold 1700 Trip 125A, 3-Pole, 600 Vac, HDA I-Line Breaker - Trip Setting: 900 Hold 1700 Trip 150A, 3-Pole, 600 Vac, HDA I-Line Breaker - Trip Setting: 900 Hold 1700 Trip Square D - Type JDA, 600V, 3P, J-Frame Breakers QOJDA36 Square D - JDA Circuit Breakers J-frame Circuit Breakers for I-Line Panelboards and Switchboards Class 612. Thermal-magnetic (600 Vac) with Factory Sealed Trip Units. 3-pole, 600 Vac 50/60 Hz. 200A or 225A "D" interrupting. QOJDA36200 QOJDA A, 3-Pole, 600 Vac, JDA I-Line Breaker - Trip Setting: 1000 Low 2000 High 225A, 3-Pole, 600 Vac, JDA I-Line Breaker - Trip Setting: 1125 Low 2250 High Does Not Contain Clearance Items 15

18 Circuit Breakers Square D - Circuit Breakers Circuit Breakers for I-Line Panelboards Circuit Breakers Square D - Type LA, 600V, 3P, L-Frame Breaker QOLA36400 Square D - LA36400 Circuit Breaker 400A Molded Case Circuit Breaker for I-Line Panelboards and Switchboards Class 660, 665, 670, 830. L Frame mounting style, Thermal magnetic 600Vac 250Vdc. 3-pole, 400A, standard interrupting. AC Magnetic Trip Settings: Low 2000, High QOLA A, 3-Pole, 600V L-Frame I-Line Circuit Breaker Square D - Type QBA, 240V, 3P, Q-Frame Breakers QOQBA32 Square D - QBA 3-Pole Circuit Breakers The 3-Pole Powerpact Circuit Breakers are for I-Line Panelboards and Switchboards Class 650, 734, 820. Thermalmagnetic (240Vac), complete without additional phasing number. 200A or 225A "B" interrupting. Trip Settings: Hold 1200 Trip QOQBA32200 QOQBA32225 Homeline Plug-On Circuit Breakers 1-Pole Standard - QO HOM1 200A, 3-Pole, 240V Powerpack Q-frame I-Line Breaker, "B" Interupting 10kA 225A, 3-Pole, 240V Powerpack Q-frame I-Line Breaker, "B" Interupting 10kA Homeline Standard 1-Pole Circuit Breakers - QOHOM1x Provides overload and short circuit protection. Designed to plug into Homeline load centers. 1-Pole, 120/240Vac, 1" wide. 1 Space Required. 10,000 AIR. QOHOM115 QOHOM120 QOHOM130 2-Pole Standard - QO HOM2 15A, 1-Pole, 120/240Vac Homeline Plug-On Circuit Breaker 20A, 1-Pole, 120/240Vac Homeline Plug-On Circuit Breaker 30A, 1-Pole, 120/240Vac Homeline Plug-On Circuit Breaker Homeline Standard 2-Pole Circuit Breakers - QOHOM2x Provides overload and short circuit protection. Designed to plug into Homeline load centers. 2-Pole, 120/240Vac, Common Trip. 2 spaces required. 10,000 AIR. QOHOM2100 QOHOM2125 QOHOM215 QOHOM220 QOHOM225 QOHOM230 QOHOM A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 125A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 15A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 20A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 25A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 30A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 35A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers Does Not Contain Clearance Items 16

19 Circuit Breakers Square D - Circuit Breakers Homeline Plug-On Circuit Breakers 2-Pole Standard - QO HOM2 QOHOM240 QOHOM245 QOHOM250 QOHOM260 QOHOM270 QOHOM280 QOHOM290 40A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 45A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 50A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 60A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 70A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 80A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers 90A, 2-Pole, 120/240Vac, Common Trip Homeline Plug-On Circuit Breakers Arc & Ground Fault Circuit Bkrs - QO HOM-DF Circuit Breakers Square D - Homeline DF Dual Function Circuit Breakers Square D - Homeline DF Dual Function Circuit Breakers. Combination Arc-Fault & Ground Ground Fault Circuit Interrupter with Pigtail Neutral. (Dual Function). Provide overload & short circuit protection, plus arc fault/ground fault protection in a single device in accordance with the NEC, UL1699 & UL943. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOHOM115DF QOHOM120DF 15A, 1-Pole, 120Vac, Homeline Combination Arc Fault and Ground Fault Circuit Interrupters, Pigtail Neutral 20A, 1-Pole, 120Vac, Homeline Combination Arc Fault and Ground Fault Circuit Interrupters, Pigtail Neutral Arc & Ground Fault Circuit Bkrs - QO HOM-PDF Square D - Homeline PDF Dual Function Circuit Breakers Plug-on neutral combination arc-fault and ground fault miniature circuit breaker (dual function) Provides overload and short circuit protection, plus arc fault and ground fault protection in accordance with the NEC, UL1699 and UL973. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOHOM115PDF QOHOM120PDF 15A, 1-Pole, 120Vac, Homeline Combination Arc Fault and Ground Fault Circuit Interrupters, Plug-On Neutral 20A, 1-Pole, 120Vac, Homeline Combination Arc Fault and Ground Fault Circuit Interrupters, Plug-On Neutral Combination Arc Fault Int. - QO HOM-CAFI Homeline CAFI Circuit Breakers - QOHOM-CAFI Homeline Combination Arc Fault Circuit Interrupter with pigtail neutral. Provides overload and short circuit protection, plus arc fault protection in accordance with UL ,000 AIR. Designed for Homeline load centers. QOHOM115CAFI QOHOM120CAFI QOHOM215CAFI QOHOM220CAFI 15A, 120Vac, 1-Pole, 1 Space, Homeline Combination Arc Fault Circuit Interrupter Circuit Breaker, with Pigtail Neutral 20A, 120Vac, 1-Pole, 1 Space, Homeline Combination Arc Fault Circuit Interrupter Circuit Breaker, with Pigtail Neutral 15A, 120Vac, 2-Pole, 2 Space, Homeline Combination Arc Fault Circuit Interrupter Circuit Breaker, with Pigtail Neutral 20A, 120Vac, 2-Pole, 2 Space, Homeline Combination Arc Fault Circuit Interrupter Circuit Breaker, with Pigtail Neutral Does Not Contain Clearance Items 17

20 Circuit Breakers Square D - Circuit Breakers Homeline Plug-On Circuit Breakers Circuit Breakers Combination Arc Fault Int. - QO HOM-PCAFI Homeline PCAFI Plug-On Circuit Breakers Plug-on neutral combination arc fault interrupters provide overload and short circuit protection, plus arc fault protection in accordance with the NEC and UL1699. Connects directly to the neutral bar within the load center, providing a cleaner, time and labor-saving installation without the pigtail connection. QOHOM115PCAFI QOHOM120PCAFI 15A, 1-Pole 120Vac, Plug-On Neutral Combination Arc-Fault Interrupter Homeline Circuit Breaker 20A, 1-Pole 120Vac, Plug-On Neutral Combination Arc-Fault Interrupter Homeline Circuit Breaker Ground Fault Interrupter - QO HOM-GFI Homeline GFI Circuit Breakers - QOHOM-GFI Homeline plug-on ground fault circuit interrupter circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 millamperes or more. 10,000 AIR. QOHOM115GFI QOHOM120GFI QOHOM215GFI QOHOM220GFI QOHOM230GFI QOHOM240GFI QOHOM250GFI Quad Tandem - QO HOMT 15A, 1-Pole, 120Vac, 1 Space Required, Homeline Ground Fault Interrupter Circuit Breaker 20A, 1-Pole, 120Vac, 1 Space Required, Homeline Ground Fault Interrupter Circuit Breaker 15A, 2-Pole, 120/240Vac, Common Trip, 2 Spaces Required, Homeline Ground Fault Interrupter Circuit Breaker 20A, 2-Pole, 120/240Vac, Common Trip, 2 Spaces Required, Homeline Ground Fault Interrupter Circuit Breaker 30A, 2-Pole, 120/240Vac, Common Trip, 2 Spaces Required, Homeline Ground Fault Interrupter Circuit Breaker 40A, 2-Pole, 120/240Vac, Common Trip, 2 Spaces Required, Homeline Ground Fault Interrupter Circuit Breaker 50A, 2-Pole, 120/240Vac, Common Trip, 2 Spaces Required, Homeline Ground Fault Interrupter Circuit Breaker HOMT Quad Tandem Circuit Breakers - QOHOMTx Provides overload and short circuit protection. For use with Homeline load centers. Class 1170, 2-Pole Tandem, 120/240Vac (two spaces required). Typically has two 1P outer poles and one 2P inner circuit breaker with common trip. AC/Heating Equipment Rated. 10,000 AIR. QOHOMT QOHOMT Tandem - 1-Space - QO HOMT Homeline Quad Tandem Circuit Breakers - Ampere Rating: 2-15A/1-Pole, 1-30A/2-Pole - 2 Spaces Required Homeline Quad Tandem Circuit Breakers - Ampere Rating: 2-20A/1-Pole, 1-30A/2-Pole - 2 Spaces Required HOMT Tandem Circuit Breakers - QOHOMTx Provides overload and short circuit protection. For use with Homeline load centers. Class 1170, 1-Pole tandem, 120/240 Vac (One space required). AC/Heating Equipment Rated. 10,000 AIR. QOHOMT1515 QOHOMT1520 QOHOMT2020 Homeline 1-Pole Tandem Plug-On Circuit Breaker - Ampere Rating: 15A & 15A - 1 Space Required Homeline 1-Pole Tandem Plug-On Circuit Breaker - Ampere Rating: 15A & 20A - 1 Space Required Homeline 1-Pole Tandem Plug-On Circuit Breaker - Ampere Rating: 20A & 20A - 1 Space Required Does Not Contain Clearance Items 18

21 Circuit Breakers Square D - Circuit Breakers Miniature Circuit Breakers - QOU Unit Mount QOU Mounting Foot Square D QOU Mounting Foot For use on low and high ampere QOU circuit breakers. Circuit Breakers QOUMF1B QOUMF2B QOUMF3B QOU Series Breakers 1-Pole QOU Circuit Breaker Mounting Foot 2-Pole QOU Circuit Breaker Mounting Foot 3-Pole QOU Circuit Breaker Mounting Foot Square D - QOU Series Miniature Circuit Breakers Class 720 ampere QOU miniature circuit breakers are unit-mount (lug/lug) thermal magnetic circuit breakers. 120/240 Vac Rating. 10,000 AIR. They provide a means to manually open a circuit. Automatically open a circuit under overload or short circuit conditions. Feature common tripping of all poles. Have a Visi-Trip trip indicator. Can be flush, surface, or DIN rail mounted. Have lugs at both ends (cable-in/cable-out construction) Operate in any position. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOU110 QOU110B QOU115 QOU115B QOU120 QOU120B QOU125B QOU130 QOU130B QOU140 QOU210B QOU215 QOU215B QOU220 QOU220B QOU225B QOU230 QOU230B QOU240 QOU240B QOU250 QOU250B QOU260 QOU260B QOU280 QOU315B QOU320 QOU320B QOU330 QOU330B 10A, 1-Pole, 120/240 Vac, QOU Miniature Breaker 10A, 1-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 15A, 1-Pole, 120/240 Vac, QOU Miniature Breaker 15A, 1-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 20A, 1-Pole, 120/240 Vac, QOU Miniature Breaker 20A, 1-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 25A, 1-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 30A, 1-Pole, 120/240 Vac, QOU Miniature Breaker 30A, 1-Pole, 120/240 Vac. QOU Miniature Breaker, Bulk 40A, 1-Pole, 120/240 Vac, QOU Miniature Breaker 10A, 2-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 15A, 2-Pole, 120/240 Vac, QOU Miniature Breaker 15A, 2-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 20A, 2-Pole, 120/240 Vac, QOU Miniature Breaker 20A, 2-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 25A, 2-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 30A, 2-Pole, 120/240 Vac, QOU Miniature Breaker 30A, 2-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 40A, 2-Pole, 120/240 Vac, QOU Miniature Breaker 40A, 2-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 50A, 2-Pole, 120/240 Vac, QOU Miniature Breaker 50A, 2-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 60A, 2-Pole, 120/240 Vac, QOU Miniature Breaker 60A, 2-Pole, 120/240 Vac, QOU Miniature Breaker, Bulk 80A, 2-Pole, 120/240 Vac, QOU Miniature Breaker 15A, 3-Pole, 240 Vac, QOU Miniature Breaker, Bulk 20A, 3-Pole, 240 Vac, QOU Miniature Breaker 20A, 3-Pole, 240 Vac, QOU Miniature Breaker, Bulk 30A, 3-Pole, 240 Vac, QOU Miniature Breaker 30A, 3-Pole, 240 Vac, QOU Miniature Breaker, Bulk Does Not Contain Clearance Items 19

22 Circuit Breakers Square D - Circuit Breakers Miniature Circuit Breakers - QOU Unit Mount Circuit Breakers QOU Series Breakers QOU340 40A, 3-Pole, 240 Vac, QOU Miniature Breaker QOU340B 40A, 3-Pole, 240 Vac, QOU Miniature Breaker, Bulk QOU360 60A, 3-Pole, 240 Vac, QOU Miniature Breaker QOU370B 70A, 3-Pole, 240 Vac, QOU Miniature Breaker, Bulk Square D - Circuit Breakers - Molded Case - Thermal - Magnetic F-Frame 3-Pole 480Vac, Lugs Both Ends - QO FAL Square D - HDL 3-Pole 600Vac Circuit Breakers Type HDL PowerPact 3-Pole thermal-magnetic current limiting circuit breakers with factory sealed trip unit (suitable for reverse connection) 150A H-Frame unit mount. 600 Vac 50/60Hz, 250 Vdc. Standard interrupting with lugs on both ends. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOFAL34020 QOFAL34030 QOFAL34060 QOFAL A, 3-Pole, 480Vac, FAL Breaker - AC Mag Trip Settings 275 Hold, 600 Trip 30A, 3-Pole, 480Vac, FAL Breaker - AC Mag Trip Settings 275 Hold, 600 Trip 60A, 3-Pole, 480Vac, FAL Breaker - AC Mag Trip Settings 800 Hold, 1450 Trip 100A, 3-Pole, 480Vac, FAL Breaker - AC Mag Trip Settings 900 Hold, 1700 Trip H-Frame 3-Pole 600Vac, Lugs Both Ends - QO HDL Square D - FAL 3-Pole 480Vac Circuit Breakers Type FAL 3-Pole thermal-magnetic molded case circuit breakers are permanent trip UL Listed, CSA Certified, IEC rated, and also meet the requirement of Fed. Specification W-C-375B/GEN. 100 Ampere F-Frame unit mount. 480 Vac, 250 Vdc. Standard interrupting with lugs on both ends. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOHDL36015 QOHDL36020 QOHDL36060 QOHDL36100 QOHDL36125 QOHDL A, 3-Pole 600Vac HDL Breaker - AC Mag Trip Settings 350 Hold, 750 Trip 20A, 3-Pole 600Vac HDL Breaker - AC Mag Trip Settings 350 Hold, 750 Trip 60A, 3-Pole 600Vac HDL Breaker - AC Mag Trip Settings 800 Hold, 1450 Trip 100A, 3-Pole 600Vac HDL Breaker - AC Mag Trip Settings 900 Hold, 1700 Trip 125A, 3-Pole 600Vac HDL Breaker - AC Mag Trip Settings 900 Hold, 1700 Trip 150A, 3-Pole, 600Vac HDL Breaker - AC Mag Trip Settings 900 Hold, 1700 Trip J-Frame 3-Pole 600Vac, Lugs Both Ends - QO JDL Square D - JDL 3-Pole 600Vac Circuit Breakers Type JDL PowerPack 3-Pole thermal-magnetic current limiting circuit breakers with factory sealed trip unit (suitable for reverse connection) 250A J-Frame unit mount. 600 Vac 50/60Hz, 250 Vdc. Standard interrupting with lugs on both ends. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOJDL36200 QOJDL A, 3-Pole, 600Vac JDL Breaker - Fixed AC Magnetic Trip 1000 Hold, 2000 Trip 220A, 3-Pole, 600Vac JDL Breaker - Fixed AC Magnetic Trip 1125 Hold, 2250 Trip Does Not Contain Clearance Items 20

23 Circuit Breakers Square D - Circuit Breakers Square D - Circuit Breakers - Molded Case - Thermal - Magnetic L-Frame 3-Pole 600Vac, Lugs Both Ends - QO LAL Square D - LAL 3-Pole 600Vac Circuit Breakers Type LAL 3-Pole thermal-magnetic molded case circuit breakers. 400A L-Frame unit mount. 600Vac, 250 Vdc. Standard Interrupting with lugs on both ends. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers Circuit Breakers QOLAL36400 QOLAL36400MB 400A, 3-Pole, 600Vac LAL Circuit Breaker - AC Mag Trip Settings 2000 Low, 4000 High 400A, 3-Pole, 600Vac LAL Circuit Breaker w/ Shorter Handle - AC Mag Trip Settings 2000 Low, 4000 High Q-Frame 2-Pole 240Vac, Lugs Both Ends - QO QBL Square D - QBL 3-Pole 240Vac Circuit Breakers PowerPact Q-Frame molded case circuit breakers. 2-Pole 240Vac, Unit mount. Type QBL - B interrupting 10 ka with lugs on both ends. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOQBL22100 QOQBL22150 QOQBL22200 QOQBL A, 2-Pole, 240Vac Q-frame Breaker - Fixed AC Magnetic Trip 1200 Hold, 2400 Trip 150A, 2-Pole, 240Vac Q-frame Breaker - Fixed AC Magnetic Trip 1200 Hold, 2400 Trip 200A, 2-Pole, 240Vac Q-frame Breaker - Fixed AC Magnetic Trip 1200 Hold, 2400 Trip 225A, 2-Pole, 240Vac Q-frame Breaker - Fixed AC Magnetic Trip 1200 Hold, 2400 Trip Q-Frame 3-Pole 240Vac, Lugs Both Ends - QO QBL Square D - QBL 3-Pole 240Vac Circuit Breakers PowerPact Q-Frame molded case circuit breakers. 2-Pole 240Vac, Unit mount. Type QBL - B interrupting 10 ka with lugs on both ends. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOQBL32125 QOQBL32150 QOQBL32200 QOQBL A, 3-Pole, 240Vac Q-frame Breaker - Fixed AC Magnetic Trip 1200 Hold, 2400 Trip 150A, 3-Pole, 240Vac Q-frame Breaker - Fixed AC Magnetic Trip 1200 Hold, 2400 Trip 200A, 3-Pole, 240Vac Q-frame Breaker - Fixed AC Magnetic Trip 1200 Hold, 2400 Trip 225A, 3-Pole, 240Vac Q-frame Breaker - Fixed AC Magnetic Trip 1200 Hold, 2400 Trip Circuit Breakers for NF Panelboards - QO EDB Square D - QBA 3-Pole Circuit Breakers The 3-Pole Powerpact Circuit Breakers are for I-Line Panelboards and Switchboards Class 650, 734, 820. Thermalmagnetic (240Vac), complete without additional phasing number. 200A or 225A "B" interrupting. Trip Settings: Hold 1200 Trip QOEDB14020 QOEDB24020 QOEDB A E-Frame Breaker - 1-Pole, 277 Vac, "D" Interrupting Level 20A E-Frame Breaker - 2-Pole, 480Y/277 Vac, "D" Interrupting Level 15A E-Frame Breaker - 3-Pole, 480Y/277 Vac, "D" Interupting Level Does Not Contain Clearance Items 21

24 Circuit Breakers Square D - Circuit Breakers Circuit Breakers Circuit Breakers for NF Panelboards - QO EDB QOEDB A E-Frame Breaker - 3-Pole, 480Y/277 Vac, "D" Interupting Level QOEDB A E-Frame Breaker - 3-Pole, 480Y/277 Vac, "D" Interupting Level QOEDB A E-Frame Breaker - 3-Pole, 480Y/277 Vac, "D" Interupting Level QOEDB A E-Frame Breaker - 3-Pole, 480Y/277 Vac, "D" Interupting Level QOEDB A E-Frame Breaker - 3-Pole, 480Y/277 Vac, "D" Interupting Level QOEDB A E-Frame Breaker - 3-Pole, 480Y/277 Vac, "D" Interupting Level QOEDB A E-Frame Breaker - 3-Pole, 480Y/277 Vac, "D" Interupting Level QO Plug-On Neutral Circuit Breakers Square D QO Plug-On CAFI Circuit Breakers QO Plug-On combination arc fault interrupter circuit breakers are designed to reduce installation time and reduce clutter in the wire gutter. Comes standard with TIME SAVER diagnostics, helping reduce troubleshooting time by indentifying the type of fault that has occurred. Designed for use in QO Plug-On Neutral Load Centers Only. UL Listed. QO115PCAFI QO120PCAFI 15A QO Plug-On Neutral CAFI Circuit Breaker. 1-Pole, 120Vac 10k AIR, 1-Space Required 20A QO Plug-On Neutral CAFI Circuit Breaker. 1-Pole, 120Vac 10k AIR, 1-Space Required Square D - Circuit Breakers - QO QO Circuit Breakers QO Replacement Tandem Breakers Square D - QO Replacement Tandem Breakers QO Plug-on miniature replacement tandem circuit breakers. For use in old style non-class CTL QO Load Centers (replacement only). 1-Pole, 1 space required. Voltage Rating: 120/240VAC. Short Circuit Current Rating: 10kA. Visi-Trip trip indication. Provides overload and short circuit protection UL listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. We stock authentic Square D Breakers.Beware: The DANGERS of Counterfeit Breakers QO1515 QO1520 QO A & 15A 1-Pole Replacement Tandem Breakers for use in Old Style Non-Class CTL QO Load Ctrs. 15A & 20A 1-Pole Replacement Tandem Breakers for use in Old Style Non-Class CTL QO Load Ctrs. 20A & 20A 1-Pole Replacement Tandem Breakers for use in Old Style Non-Class CTL QO Load Ctrs. QO-CAFI Combo Arc-Fault Circuit Breakers Square D - QO-CAFI Circuit Breakers Miniature Plug-On QO Circuit Breakers with combination arc-fault interrupter protection. Provides protection for Series and Parallel Type Arcing as required by the NEC and local code adoption, and comply with UL Provides arc-fault protection for the branch circuit and also provides protection of cord sets and power supply cords. Fits into most Square D load centers as a direct replacement for a standard circuit breaker. 10,000 AIR. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QO115CAFI QO120CAFI QO215CAFI QO220CAFI 15A 1-Pole, 120Vac Combination Arc Fault Interrupter Circuit Breaker, Pigtail Neutral 20A 1-Pole, 120Vac Combination Arc Fault Interrupter Circuit Breaker, Pigtail Neutral 15A 2-Pole, 120/240 Vac, Combination Arc Fault Interrupter Circuit Breaker, Pigtail Neutral 20A 2-Pole, 120/240 Vac, Combination Arc Fault Interrupter Circuit Breaker, Pigtail Neutral Does Not Contain Clearance Items 22

25 Circuit Breakers Square D - Circuit Breakers - QO QO Circuit Breakers QO-DF Dual Function Pigtail Bkrs Square D - DF Dual Function Circuit Breakers Combination arc-fault and ground fault miniature circuit breaker with pigtail neutral (dual function). 1-Pole, 120 VAC. 1 Space required. 10,000 AIR. Provides overload and short circuit protection, plus arc fault and ground fault protection in accordance with the NEC, UL1699 and UL943. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers Circuit Breakers QO115DF QO120DF QO-HM High Magnetic Trip Breakers 15A 1-Pole, 120Vac Dual Function Arc-fault and Ground Fault Circuit Interrupter, Pigtail Neutral - 10,000 Air 20A 1-Pole, 120Vac Dual Function Arc-fault and Ground Fault Circuit Interrupter, Pigtail Neutral - 10,000 Air Square D - QO120HM Circuit Breaker QO plug-on miniature circuit breaker, high magnetic. 20A, 120VAC. 1-Pole, 1 Space. Wire size: #14 to #8 AWG (Al/Cu) Short Circuit Current Rating: 10kA. Switching Duty Rated. Visi-Trip trip indication. Provides overload and short circuit protection. Recommended for applicaitons where high initial inrush may occur. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QO120HM QOM Main Circuit Breaker Kits 20A 1-Pole, 120Vac High Magnetic Trip Circuit Breaker Square D QOM Main Circuit Breaker Kits Main breakers for QO and Homeline Load Centers. Field-installable, convertible load centers only. Standard 2-Pole, 240VAC, 1-Phase. Mounting type: Bolt-On. Terminal type: Box Lugs. Short Circuit Current Rating: 22kA. QOM100VH QOM2125VH QOM2150VH QOM2200VH QOM2225VH QO-PDF Dual Function Plug-On Bkrs 100A, 240VAC, 2-Pole, 1-PH Main Circuit Breaker Kit, Type QOM1, Wire Size: #4 to #2/0 AWG(Al/Cu) 125A, 240VAC, 2-Pole, 1-PH Main Circuit Breaker Kit, Type QOM2, Wire Size: #4-300AWG/kcmil(Al/Cu) 150A, 240VAC, 2-Pole, 1-PH Main Circuit Breaker Kit, Type QOM2, Wire Size: #4-300AWG/kcmil(Al/Cu) 200A, 240VAC, 2-Pole, 1-PH Main Circuit Breaker Kit, Type QOM2, Wire Size: #4-300AWG/kcmil(Al/Cu) 225A, 240VAC, 2-Pole, 1-PH Main Circuit Breaker Kit, Type QOM2, Wire Size: #4-300AWG/kcmil(Al/Cu) Square D - Homeline PDF Dual Function Circuit Breakers Plug-on neutral combination arc-fault and ground fault miniature circuit breaker (dual function). 1-Pole, 120 Vac. 1 Space required. 10,000 AIR. Provides overload and short circuit protection, plus arc fault and ground fault protection in accordance with the NEC, UL1699 and UL943. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QO115PDF QO120PDF 15A 1-Pole, 120Vac Combination Arc-fault and Ground Fault Circuit Interrupter, Plug-on Neutral - 10,000 Air 20A 1-Pole, 120Vac Combination Arc-fault and Ground Fault Circuit Interrupter, Plug-on Neutral - 10,000 Air Does Not Contain Clearance Items 23

26 Circuit Breakers Square D - Circuit Breakers - QO QO Circuit Breakers Circuit Breakers QO-QB Main Circuit Breaker Kits Square D QB Main Circuit Breakers 200A, 240VAC, 2-Pole Molded case Main circuit breakers. QOQBM22200TN QOQBP22200TM QO-SWN Switch Neutral Common Trip 200A 2-Pole, 240V Molded Case Main Circuit Breaker, Replacement for Old Style 200A 2-Pole, 240V Molded Case Main Circuit Breaker Square D - QO220SWN Switch Neutral Breaker QO Plug-On Miniature Circuit Breaker with switch neutral common trip. 20A, Two wire, two spaces required. Wire Size: #14 to #8 AWG (AL/Cu). Short Circuit Current Rating: 10kA. Voltage Rating: 120VAC. Visi-Trip trip indication. Provides overload and short circuit protection. Designed to protect gas pump assemblies NEC We stock authentic Square D Breakers.Beware: The DANGERS of Counterfeit Breakers QO220SWN QOT Tandem Circuit Breakers 20A, 2-Pole, 2-Wire, 120Vac, Switch Neutral Common Trip, Circuit Breaker Square D - QOT Tandem Circuit Breakers QOT Plug-On miniature tandem circuit breakers. 1-Pole, 1-phase.Voltage rating: 120/240VAC. Short Circuit Current Rating: 10kA. Visi-Trip trip indication. Provides overload and short circuit protection. Order two QOT1515 or QOT2020 circuit breakers and handle tie QOTHT for common switching of center two poles. UL listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. We stock authentic Square D Breakers.Beware: The DANGERS of Counterfeit Breakers QOT1515 QOT2020 QO Miniature Plug-On Breakers Square D QO 1-Pole Circuit Breakers 15A & 15A 1-Pole Tandem Circuit Breaker - 120/240Vac 10,000 AIR 20A & 20A 1-Pole Tandem Circuit Breaker - 120/240Vac 10,000 AIR Square D - B Series 1-Pole Circuit Breakers QOB Miniature Bolt-On thermal-magnetic circuit breakers with Visi-Trip Indicator. For use in NQ & NQOD Panelboards/Interiors. Provides overload and short circuit protection. 120 Vac - 10,000 AIR, 48 Vdc - 5,000 AIR. General duty application. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QO110 QO115 QO120 QO QO125 QO130 QO140 QO150 10A 1-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 15A 1-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 20A 1-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 20A 1-Pole, 120/240Vac, 10,000 AIR Circuit Breaker with AC 120/208/240 Shunt Trip 25A 1-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 30A 1-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 40A 1-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 50A 1-Pole, 120/240Vac, 10,000 AIR Circuit Breakers Does Not Contain Clearance Items 24

27 Circuit Breakers Square D - Circuit Breakers - QO QO Miniature Plug-On Breakers Square D QO 2-Pole Circuit Breakers Square D - B Series 2-Pole Circuit Breakers QOB Miniature Bolt-On thermal-magnetic circuit breakers with Visi-Trip Indicator. For use in NQ & NQOD Panelboards/Interiors. Provides overload and short circuit protection. 120 Vac / 120/240 Vac - 10,000 AIR, 48 Vdc - 5,000 AIR. 2-Pole with common trip, general duty application. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breaker Circuit Breakers QO210 QO2100 QO2125 QO215 QO2150 QO220 QO2200 QO225 QO230 QO235 QO240 QO245 QO250 QO260 QO270 QO280 QO290 Square D QO 3-Pole Circuit Breakers 10A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 100A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 125A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 15A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 150A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers, for use in Single Phase Panels Only 20A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 200A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers, For use in Single Phase Panels Only 25A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 30A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 35A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 40A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 45A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 50A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 60A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 70A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 80A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers 90A 2-Pole, 120/240Vac, 10,000 AIR Circuit Breakers Square D - B Series 3-Pole Circuit Breakers QOB Miniature Bolt-On thermal-magnetic circuit breakers with Visi-Trip Indicator. For use in NQ & NQOD Panelboards/Interiors. Provides overload and short circuit protection. 120/240 Vac - 10,000 AIR, 48 Vdc - 5,000 AIR. 3- Pole with common trip, general duty application. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QO3100 QO315 QO320 QO330 QO340 QO350 QO360 QO370 QO380 QO A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers 15A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers 20A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers 30A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers 40A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers 50A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers 60A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers 70A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers 80A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers 90A 3-Pole, 240Vac Common Trip Plug-On Circuit Breakers Does Not Contain Clearance Items 25

28 Circuit Breakers Square D - Circuit Breakers - QO QOB Miniature Bolt-On Breakers Circuit Breakers Square D QOB Series 1-Pole Square D - QO 2-Pole Circuit Breakers QO miniatuire plug-on thermal magnetic circuit breakers with Visi-Trip indicator. For use in QO load centers. Provides overload and short circuit protection. 2-Pole, 2 spaces required, common trip. 120/240 Vac - 10,000 AIR. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOB115 QOB120 QOB120GFI QOB125 QOB130 Square D QOB Series 2-Pole 15A, 1-Pole, 120Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 20A, 1-Pole, 120Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 20A, 1-Pole, 120V, QOB Bolt-On Circuit Breaker With Ground Fault Circuit Interrupter - 10,000 AIR 25A, 1-Pole, 120Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 30A, 1-Pole, 120Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR Square D - QO 2-Pole Circuit Breakers QO miniatuire plug-on thermal magnetic circuit breakers with Visi-Trip indicator. For use in QO load centers. Provides overload and short circuit protection. 2-Pole, 2 spaces required, common trip. 120/240 Vac - 10,000 AIR. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOB2100 QOB215 QOB220 QOB230 QOB240 QOB250 QOB260 QOB270 Square D QOB Series 3-Pole 100A, 2-Pole Common Trip, 120/240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 15A, 2-Pole Common Trip, 120/240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 20A, 2-Pole Common Trip, 120/240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 30A, 2-Pole Common Trip, 120/240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 40A, 2-Pole Common Trip, 120/240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 50A, 2-Pole Common Trip, 120/240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 60A, 2-Pole Common Trip, 120/240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 70A, 2-Pole Common Trip, 120/240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR Square D - QO 3-Pole Circuit Breakers QO miniature plug-on thermal magnetic circuit breakers with Visi-Trip indicator. For use in QO load centers. Provides overload and short circuit protection. 3-Pole, 3 spaces required, common trip. 120/240 Vac, 10,000 AIR. We stock authentic Square D Breaker. Beware: The DANGERS of Counterfeit Breakers QOB3100 QOB3125VH QOB315 QOB3150VH QOB320 QOB330 QOB340 QOB350 QOB360 QOB A, 3-Pole Common Trip, 240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 125A, 3-Pole, 6 Pole Spaces Required, 240Vac, QOB Bolt-On Circuit Breaker - 22,000 AIR 15A, 3-Pole Common Trip, 240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 150A, 3-Pole, 6 Pole Spaces Required, 240Vac, QOB Bolt-On Circuit Breaker - 22,000 AIR 20A, 3-Pole Common Trip, 240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 30A, 3-Pole Common Trip, 240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 40A, 3-Pole Common Trip, 240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 50A, 3-Pole Common Trip, 240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 60A, 3-Pole Common Trip, 240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR 70A, 3-Pole Common Trip, 240Vac, QOB Bolt-On Circuit Breaker - 10,000 AIR Does Not Contain Clearance Items 26

29 Circuit Breakers Square D - Circuit Breakers - QO QO-GFI Plug-On Circuit Breakers Square D QO 1-Pole GFI Square D - QO-GFI 1-Pole Circuit Breakers QO-GFI Qwik-Gard Ground Fault Interrupter miniature circuit breakers. 1-Pole, 120 Vac Max. rated voltage. 1-Phase, one space required. Mounting Type: Plug-on. Short Circuit Current Rating: 10kA. Aluminum Wire Size: #12-8. Copper Wire Size: #14-8. Visi-Trip trip indication. Provides overload and short circuit protection. Designed to offer Class A (6mA) ground-fault protection for people. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. Circuit Breakers QO115GFI QO120GFI QO130GFI Square D QO 2-Pole GFI 15A 1-Pole, 120Vac Circuit Breaker With Ground Fault Circuit Interrupter 20A 1-Pole, 120Vac Circuit Breaker With Ground Fault Circuit Interrupter 30A 1-Pole, 120Vac Circuit Breaker With Ground Fault Circuit Interrupter Square D - QO-GFI 2-Pole Circuit Breakers QO-GFI Qwik-Gard Ground Fault Interupter miniature circuit breaker. 120/240VAC, 1-Phase. 2-Pole common trip, two spaces required. Short Circuit Current Rating: 10kA. Aluminum Wire Size: #12-8. Copper Wire Size: #14-8. Visi-Trip trip indication. Provides overload and short circuit protection. Designed to offer Class A (6mA) ground-fault protection for people. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. QO220GFI QO230GFI QO240GFI QO250GFI QO260GFI UBI - Circuit Breakers UBI - Type P Plug-In Breakers 20A 2-Pole Common Trip, 120/240Vac Circuit Breaker With Ground Fault Interrupter 30A 2-Pole Common Trip, 120/240Vac Circuit Breaker With Ground Fault Interrupter 40A 2-Pole Common Trip, 120/240Vac Circuit Breaker With Ground Fault Interrupter 50A 2-Pole Common Trip, 120/240Vac Circuit Breaker With Ground Fault Interrupter 60A 2-Pole Common Trip, 120/240Vac Circuit Breaker With Ground Fault Interrupter UBI Type P Circuit Breakers Plug-In, SWD rated, circuit breakers. 120/240VAC. 10,000 AIC. Suitable replacement for Pushmatic. We stock authentic UBI Breakers UBIP115 UBIP120 UBIP220 UBIP230 UBIP250 15A, 1-Pole, Type P Plug-In Circuit Breaker, 120/240V, 10,000 AIC 20A, 1-Pole, Type P Plug-In Circuit Breaker, 120/240V, 10,000 AIC 20A, 2-Pole, Type P Plug-in Circuit Breaker, 120/240V, 10,000 AIC 30A, 2-Pole, Type P Plug-in Circuit Breaker, 120/240V, 10,000 AIC 50A, 2-Pole, Type P Plug-in Circuit Breaker, 120/240V, 10,000 AIC Does Not Contain Clearance Items 27

30 Circuit Breakers Wadsworth - Circuit Breakers Wadsworth 1-Pole Type A Circuit Breaker Circuit Breakers Wadsworth Type A 1- Pole Circuit Breaker Single pole, plug-in circuit breaker. Voltage rating: 120/240. We stock authentic Wadsworth Breakers WADA15NI WADA20NI WADA30NI 15A, 1-Pole Plug-in, Ciruit Breaker, 120/240 Volts 20A, 1-Pole Plug-in, Circuit Breaker, 120/240 Volts 30A, 1-Pole Plug-in, Circuit Breaker, 120/240 Volts Wadsworth 2-Pole Type A Circuit Breaker Wadsworth Type A 2- Pole Circuit Breaker Double pole, plug in circuit breaker. Voltage rating: 120/240. We stock authentic Wadsworth Breakers WADA220NI WADA230NI WADA250NI WADA260NI 20A, 2-Pole Plug-in, Circuit Breaker, 120/240 Volts 30A, 2-Pole Plug-in, Circuit Breaker, 120/240 Volts 50A, 2-Pole Plug-in, Circuit Breaker, 120/240 Volts 60A, 2-Pole Plug-in, Circuit Breaker, 120/240 Volts Distribution-Terminal Blocks Power Distribution Blocks Power Distribution Blocks - Cable Connectors ILS-LDA Snapbloc Power Distribution Blocks LDA Snapbloc Power Distribution Blocks - Dual Rated Snapbloc offers a modular design that is easy to assemble. Lexan insulating base. Lexan is a registered trademark of the General Electric Company. Easy to assemble. UL 1059 listed 90 C 600 Volts and is CSA Certified. Connector manufactured from Electro-tin plated 6061-T6 aluminum alloy. Clear Cover maintains 2 inch spacing for service entrance applications. Multiple conductor capability. LDA's are added to LDB to obtain a multi Pole Block. Convert LDA to LDB by adding LDS-1 Side Plate. Dual Rated for Copper and Aluminum Conductor. ILSLDA STR, Die Color Code: Green, Die Index: 4 - Copper Compression Sleeve ILS-PDB Modular Power Distribution Blocks PDB Power Distribution Block - Dual Rated Range Taking for reduced inventories and flexibility. Valox* insulating base. *Valox is a registered trade name of the General Electric Company. Electro-tin plated. Manufactured from high strength 6061-T6 aluminum alloy. UL Recognized rated 90 C and is CSA Certified. Provides great flexibility in using the connector as an in line splice or to reduce conductor size. Rated for 600 Volts. Dual Rated for Copper and Aluminum Conductor. ILSPDB /0 STR, Die Color Code: Pink, Die Index: 5 - Copper Compression Sleeve Does Not Contain Clearance Items 28

31 Distribution-Terminal Blocks Power Distribution Blocks - Marathon Marathon - Power Dist. Block Distribution Power Block - Marathon MAR CH MAR CH MAR MAR MAR MAR MAR MAR MAR MAR MAR MAR MAR MARCC A, 600V, Power Distribution Block w/ Cover - 1-Pole 175A, 600V, Power Distribution Block w/ Cover - 3-Pole 175A, 600V, Power Distribution Block - 2-Pole 115As, 600V, Power Distribution Block - 1-Pole 115A, 600V, Power Splicer Block - 3-Pole 115A, 600V, Power Distribution Block - 3-Pole 115A, 600V, Power Splice Block, 1-Pole 175A, 600V, Power Distribution Block - 1-Pole 115A, 600V, Power Splice Block, 3-Pole 175A, 600V, Power Distribution Block - 3-Pole 175A, 600V, Power Splicer Block - 3-Pole 310A, 600V, Power Splicer Block - 3-Pole 380A, 600V, Power Distribution Block - 3-Pole Power Block Cover, Clear Power Distribution Blocks - Mersen Mersen Distribution-Terminal Blocks 1-Pole 620A Power Dist. Block - SMT MPDB68131 Large Power Distribution Block 1-Pole, 620A, 600 Volts. Large open style with copper connector for copper wire only. Primary Wire Range AWG/kcmil: 350-#6. Primary Openings Per Pole: 2. Secondary Wire Range AWG/kcmil: 2/0-#14. Secondary Openings per Pole: 6. Short Circuit Current Rating: 100kA with properly sized fuse. Insulators are virtually unbreakable, glass filled polycarbonate. UL & CSA Certified. SMTMPDB V Power Distribution Block, 1-Pole, 620A Cu 3-Pole 380A Power Dist. Block - SMT MPDB69073 Large Power Distribution Block - SMT MPDB Pole, 380A Cu, 310A Al dual rating, 600 Volts. Large open style w/ aluminum connectors for aluminum or copper wire. Line Wire Range: Line Openings per Pole: 1. Load Wire Range: 2/0-14. Load Openings per Pole: 6. Short Circuit Current Rating: 100kA with properly sized fuse. UL & CSA Certified. SMTMPDB V Power Distribution Block, 3-Pole, 380A Cu, 310A Al Dual Rating Does Not Contain Clearance Items 29

32 Distribution-Terminal Blocks Power Distribution Blocks - Mersen Mersen Safety Cover Kit - SMT08590 Distribution-Terminal Blocks SMT08590 Safety Cover - SMT Polycarbonate safety covers provide dead-front protection to and series power distribution blocks. One cover is needed for each pole (3-pole requires 3 covers). Each cover has a test probe hole in the center for circuit checking and each is marked with the reminder "REPLACE AFTER SERVICING EQUIPMENT". Mounting screws are supplied with cover. Safety Cover for Power Distribution Block, 1 Cover for each Pole Terminal Block Mounting Channel Kleinhuis Mounting Rail 35mm - KLE Mounting Track - KLE2933/2GL 35mm electro-galvanized slotted din rail mounting track. Length: 2m / 78.74". 7.5mm depth, 1mm steel. KLE2933/2GL Terminal Blocks - Marathon 35MM - 2 Meters Electro-Galvanized Slotted Din Rail Mount 20A 14-Pole Double Row Marathon 621-RZ Marathon Special Products 621-RZ Series Double Row Terminal Blocks 600 Volts AC/DC (Classes B/C) Base, Thermoplastic, 125 degree C. Closed Back Design. Screws, #6-32 Binder Head, Phil-Slot, Steel. Terminals, Plated Brass Poles. 7/16" Centers. Wire Range with Wire Binding Screw #12 - #22 AWG - 20 Amps. Wire Range with Sems Pressure Screw #12 - #22 AWG Stranded Copper Wire Only, 20 Amps MAR621RZ14 30A 8-Pole Double Row - Marathon A, 600V, 14-pole, Double row, terminal block, barrier #12 - #22 AWG 8-Pole Double Row Terminal Block - Marthon Special Products Series standard terminal block, closed back. 30 Amps, 600 Volts AC/DC (Class C). Copper wire only. Wire range w/ wire binding screw #10 - #14 AWG (solid recommended). Application torque: 20 in. lbs. 9/16" Centers. Electrical Ratings: 30A with Listed ring lug or unprepared wire, 600 Volts AC/DC, Short Circuit Rating: 10,000A (Default). Approved for factory and field wiring MAR308 30A, 600V, 8-Pole Double Row Terminal Block, Closed Back, #10-#14 AWG Does Not Contain Clearance Items 30

33 Distribution-Terminal Blocks Terminal Blocks - Marathon 30A or 65A 2-P Double Row - Marathon 402 MAR402 2-Pole Double Row Terminal Block - Marathon Series 600 Volts AC/DC (Class C) Double Row Terminal Block. Base: General Purpose Phenolic, 150 C (UL RTI). Closed back design. Screws, #10-32 Binder Head, Phil-Slot, Steel. Terminals, Plated Brass/ 11/16" Centers. Wire Range with wire binding screw: #10 - #22-30 Amps. Wire Range with sems pressure screw: #10 - #22 AWG stranded copper wire only, 30 Amps. Will accommodate lugs for wire sizes #6 - #16 AWG, 65 Amps. UL/CSA listed, RoHS Compliant 30-65A, 600V, AC/DC, 2-Pole Double Row Terminal Block, w/unprepared Wire or 65A w/ Lugs 70A 3-Pole Deadfront HD - Marathon 1103P Deadfront Type Terminal Block - MAR1103P 1100 Series Deadfront Type Heavy Duty Terminal Block. Electrical ratings: 70 Amps. max, 600 Volts AD/DC, Short circuit current rated for 10,000 Amps. Wire range: #4-#14 AWG Copper / #4 - #8 AWG Aluminum. UL Listed - CSA Certifed Distribution-Terminal Blocks MAR1103P 70A, 600V, 3-Pole Heavy Duty Deadfront Type Terminal Block, #4-#14 AWG Copper 85A 2-4-Pole Deadfront HD - Marathon 985GP Deadfront Type Terminal Blocks - MAR985GPx 985 Series Deadfront Type Heavy Duty Terminal Blocks. Electrical ratings: 85 Amps, 600 Volts AC/DC, Short circuit rated for 10,000 Amps. Factory and field wiring. Wire Range: #14 - #18 AWG Copper; #4 - #12 AWG Aluminum. UL Listed - CSA Certified - RoHS Compliant MAR985GP02 MAR985GP03 MAR985GP04 MAR985GP10 85A, 600V, AC/DC, 2-Pole, Deadfront Type Heavy Duty Terminal Block 85A, 600V, AC/DC, 3-Pole, Deadfront Type Heavy Duty Terminal Block 85A, 600V, AC/DC, 4-Pole, Deadfront Type Heavy Duty Terminal Block 85A, 600V, AC/DC, 10-Pole, Deadfront Type Heavy Duty Terminal Block Sectional 1/2 in. - Marathon 6H12TSCUF & EF 1/2" Sectional Terminal Blocks - MAR6H12TSCUF 70 Amps, 600 Volts (AC/DC) Flat Mount 1/2" Sectional Terminal Block. Copper wire only. Wire range with binding screw: #4 - #16 AWG. Wire termination torque: 20 in. lbs. 24 Circuits per foot. Electrical Ratings: 70A (Based on NEC Table , 75 C columns); 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial); Short circuit current rating: 10,000A (default). Factory and field wiring. MAR6H12EF - End Section MAR6H12EF MAR6H12TSCUF End Section for 1/2" Sectional Terminal Block (6H12TSCUF) 70A, 600V, 1/2" Sectional Terminal Block, #4 - #16 AWG Does Not Contain Clearance Items 31

34 Distribution-Terminal Blocks Terminal Blocks - Marathon Sectional 3/8 in. - Marathon 6G38TSF & EF Distribution-Terminal Blocks MAR6G38EF MAR6G38TSF 3/8" Sectional Terminal Blocks - MAR6G38TSF 50 Amps, 600 Volts (AC/DC) Flat Mount 3/8" Sectonal Terminal Block. Copper wire only. Wire range with wire binding screw: #8 - #18 AWG. Wire Termination Torque: 16 in. lbs. 32 Circuits per foot. Electrical Ratings: 50A (based on NEC Table , 75 C columns); 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial); Short Circuit Current Rating: 10,000A (default). Factory and field wiring. MAR6G38EF - End Section End Cap for 3/8" Sectional Terminal Block (6G38TSF) 50A, 600V, #8 - #18 AWG, 3/8" Sectional Terminal Block Flat Mount Terminal Blocks & Rails - Cutler-Hammer Terminal Blocks & Rails Eaton Cutler-Hammer Cutler-Hammer Terminal Block Accessories C-HM22K01 C-HM22K10 C-HXBACUT10 C-HXBACUT16 C-HXBACUT4D22 C-HXBAES35C C-HXBAFBS106 C-HXBANS3575P C-HXBATUT10 C-HXBUT16 C-HXBUT4 Contact Block, 22mm, 1NC Closed Contact Contact Block, 22mm, 1NO Contact End Cover for XBUT25PE Screw Connection Single Level Ground Block End Cover for XBUT16PE Screw Connection Single Level Ground Block End Cover for XBUT4D22 Screw Connection Multi-Conductor Terminal Block Universal End Stop, 1-Screw Mount 10-Position Plug-in Bridge for Cross Connections in the Bridge Shaft, for XBUT4 Screw Conn. 1-Level Through-Feed Terminal Block Din-Rail, Slotted - 79" L X.03" W X 1.75" W Partition Plate for XBUT6 Screw Conn. 1-Level Through-Feed 85A - (UL/cUL), 600V (UL/cUL), Screw Connection Single Level - Through-Feed Terminal Block, 16-4 AWG 30A - (UL/cUL), 600V (UL/cUL), Screw Connection Single Level - Through-Feed Terminal Block, AWG Terminal Blocks & Rails - Square D Linergy TR Terminal Blocks Square D - Linergy TR Terminal Blocks Square D QO Plug-On CAFI Circuit Breakers QO Plug-On combination arc fault interrupter circuit breakers are designed to reduce installation time and reduce clutter in the wire gutter. Comes standard with TIME SAVER diagnostics, helping reduce troubleshooting time by indentifying the type of fault that has occurred. Designed for use in QO Plug-On Neutral Load Centers Only. UL Listed QO9080MH239 QO9080MH339 QO9080MH379 QONSYTRAAB35 QONSYTRAABV35 1m / 39.37" Length, DIN Symmetrical Rail, Galvanized Steel, No Mounting Holes 1m / 39.37" Length, DIN 3 Symmetrical Rail, Galvanized Steel, Prepunched 2m / 78.74" Length, DIN Symmetrical Rail, Galvanized Steel, Prepunched Clip On End Stop for 35mm Din Rail, 5.2mm End Stop with Screw Mount for 35mm Din Rail, 9.5mm Does Not Contain Clearance Items 32

35 Distribution-Terminal Blocks Terminal Blocks & Rails - Square D Linergy TR Terminal Blocks Square D - Linergy TR Terminal Blocks QONSYTRAC22 QONSYTRV42 Grey - End Plate, 2.2mm Width NEMA Type LB Terminal Blocks 1000V, 32A, Screw Passthrough Terminal Block Square D NEMA Terminal Blocks Square D 9080 NEMA Terminal Blocks All Square D terminal blocks are 600V rated (exept the 9080 GT6 transient voltage suppressor, which is 120V0. Track mountable (an exception is the 9080GK6, which can be either directly mounted to a panel or on a track) Distribution-Terminal Blocks QO9080LB53 COVER ONLY for LBA365 3-Pole Power Distribution Block, Clear Plastic, 8.375W" x 5.313H" QO9080LBA Mini Aluminum Power Distribution Block, 1-Pole, Main (1) #14-2, Branch (4) #18-10 QO9080LBA Aluminum Power Distribution Block, 1-Pole, Main (1) #14-2/0, Branch (1) #14-2/0 QO9080LBA Mini Aluminum Power Distribution Block, 3-Pole, Main (1) #14-2, Branch (4) #18-10 QO9080LBA QO9080LBA QO9080LBA NEMA Type Terminal Blocks 9080G 3-Pole, Main (1) #14-2/0, Branch (6) # Aluminum Power Distribution Block 3-Pole, Main (1) #6-400 kcmil, Branch (6) # Aluminum Power Distribution Block 3-Pole, Main (1) #4-500 kcmil, Branch (12) # Aluminum Power Distribution Block Square D G NEMA Type Terminal Blocks Square D G NEMA Type Terminal Blocks Class 9080 Type G terminals blocks. Mounting: Track DIN 3, 35mm (9080GH). Max Voltage Rating: 600V. Block material: Nylon. One end-barrier is required for each assembly of like blocks. UL/CSA Listed QO9080GA6 QO9080GC6 QO9080GC6B QO9080GH10 QO9080GH11 QO9080GH136 QO9080GH236 QO9080GH710 QO9080GH73 QO9080GK6 QO9080GK6B QO9080GM6 QO9080GM6B QO9080GR6 40A 600V, Terminal Block, Flat Terminal Conn., Wire: #22 to #12 AWG, Density: 32 Sections per Ft., End Barrier: GP6B 85A 600V, Terminal Block, Box Lug Termination, Wire: #18 to #4 AWG, Density: 28 Sections per Ft., End Barrier: GC6B End Barrier for Terminal Blocks GC6 Screw-On End Clamp for 9080GH Track, Polycarbonate (Not recommended for snap-off Channel) Slip-In End Clamp for 9080GH Track, Steel w/ Indescent Chromate Film (Not to be used with 9080GE6 or GK6) 3/4" Standard Channel Mounting Track for Terminal Blocks - 36" Length 3/4" Snap-Off Channel Mounting Track for Terminal Blocks, Serrated Segments Spaced 5/16" Apart - 36" Length 6-Pole Jumper for 9080GM6 Terminal Blocks 6-Pole Jumper for 9080GK6 and 9080GR6 Terminal Blocks 40A 600V, Terminal Block, Box Lug Term., Wire: #22 to #10 AWG, Density: 35 Sections, Track or Panel Mount, End Barrier: GK6B End Barrier for Terminal Blocks GK6 30A 600V, Terminal Block, High Density, Box Lug Term., Wire: #22 to #10 AWG, Density: 51 Sections per ft., End Barrier: GM6B End Barrier for Terminal Blocks GM6, GR6 & GR6T 60A 600V, Terminal Block, Box Lug Term., Wire: #22 to #8 AWG, Density: 34 Sections per Ft., No Test Probe Adapter, End Barrier: GM6B Does Not Contain Clearance Items 33

36 Generators & Transfer Switches Transfer Switches, Power Inlet Boxes & Access. Generator Power Inlet Box C-HEGSPIB30 Power Inlet Box - C-HEGSPIB30 30A genertor power inlet box, L14-30P. Generators & Transfer Switches C-HEGSPIB30 30A Generator Power Inlet Box, L14-30P Loadcenters & Enclosures Cutler-Hammer - Loadcenters / Enclosures Eaton Cutler-Hammer Loadcenters Accessories Eaton Cutler-Hammer Loadcenter Parts & Accessories Eaton Cutler-Hammer Loadcenter Parts & Accessories C-HBSSUSE C-HGBK10 C-HGBK14 C-HGBK21 C-HGBK5 C-HLCCS C-HNL20 C-HNL30 C-HNL300 C-HTCD C-HTDL C-HWEM2 Neutral Bonding Strip with Screw for BR Type Loadcenters Ground Bar Kit, 10 Circuit Ground Bar Kit, 14 Circuit Ground Bar Kit, 21 Circuit Ground Bar Kit, 5 Circuit Cover Screws for CH Loadcenter Add-on Neutral or Ground Lug, #2/0 Max. Neutral/Ground Lug for BR and CH Series Loadcenters, 150 AMP, #3/0 Maximum Wire Size, Used as and Add-on Neutral or Ground Lug. Suitable For Use with Copper Or Aluminum Conductor. Add-on Neutral or Ground Lug, 300 kcmil Max. Loadcenter Circuit Directory, Adhesive Backed Loadcenter Door Lock Key for PRL1A Loadcenter Lock Enclosures Type ECC Circuit Breaker 1-Phase Circuit Breaker Enclosures 1-Phase Type ECC 225A Circuit Breaker Unit Enclosure - Cutler-Hammer ECC225 Single-phase, 3-wire, 240 Vac maximum, Type ECC circuit breaker unit enclosure. Order type CC circuit breaker separately. Wire size is determined by the circuit breaker installed. 10,000/25,000 AIC. Surface mount NEMA 1 enclosure. One ground lug accepting (1) #14-#2 is factory installed. Also, there are pre-drilled holes to accept a GBK5 ground bar. Approved for service entrance C-HECC225R C-HECC225S 225A, 1-Phase ECC Circuit Breaker Unit Enclosure, NEMA 3R, Order Type CC Circuit Breaker Separately "H x 9.31"W x 5.44"H 225A, 1-Phase ECC Circuit Breaker Unit Enclosure, NEMA 1, Order Type CC Circuit Breaker Separately "H x 8.88"W x 4.50"D Does Not Contain Clearance Items 34

37 Loadcenters & Enclosures Cutler-Hammer - Loadcenters / Enclosures Enclosures Type ECCVH Circuit Breaker Type ECCVH Circuit Breaker Enclosures Eaton Cutler-Hammer Type ECCVH Circuit Breaker Enclosure Order Type CC Circuit Breaker Separetly. Single-Phase and Three-Phase Circuit Breaker Enclosures -- 10/25kA/C Factory installed CCVH C-HECCVH150R C-HECCVH200R C-HECCVH200S 200 Amp, factory installed CCVH, outdoor enclosure, 25 ka/c, #2/0-/300kcmil Wire, 1-phase N3R "H x 9.31"W x 5.44"D 200 Amp, factory installed CCVH, indoor enclosure, 25 ka/c, #2/0-/300kcmil Wire, 1-phase N1 Loadcenters Type BR Main Breaker 1-Phase Type BR Main Breaker 1-Phase Eaton Cutler-Hammer Type BR Load Centers Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Features: Twin neutral design located in wireway, away from circuit breakers, means easier wiring and balancing of the load. Extra 1.5-inch knock-out for bundling allows maximum wiring gutter space for ease of wiring in compliance with NEC requirements. One-piece roll-formed metal backpan with circuit breaker alignment notches ensures accurately aligned breaker and bus tabs. Standard 14-3/8 inches (365.1 mm) wide enclosures fit snugly between wall studs. Tangential main knock-out eliminates the need for conduit offsets, which permits faster, easier installation. BR load centers feature Robertson slotted square combo screwheads, which means only one screwdriver is need for installation. Loadcenters & Enclosures C-HBR1212B100 C-HBR2020B100 C-HBR3030B100 C-HBR3030B150 C-HBR4040B AMP, 12 Space, 12 Max 1-Phase, Main Circuit Breaker Loadcenter, 12-pole, Aluminum Bus, NEMA 1- Indoor "H x 14.31"W x 3.88"D 100 AMP, 120/240V AC, 1-Phase, Main Circuit Breaker Loadcenter, 20-Space, 20-Pole, Aluminum Bus, Cover: Surface/Flush with Door, NEMA 1- Indoor. - 23"H x 14.31"W x 3.88"D 100 AMP, 120/240V AC, 1-Phase, Main Circuit Breaker Loadcenter, 30-Space, 30-Pole, Aluminum Bus, Cover: Surface/Flush with Door, NEMA 1- Indoor "H x 14.31"W x 3.88"D 150 AMP, 120/240V AC, 1-Phase, Main Circuit Breaker Loadcenter, 30-Space, 30-Pole, Aluminum Bus, Cover: Surface/Flush with Door, NEMA 1- Indoor "H x 14.31"W x 3.88"D 200 AMP, 120/240V AC, 1-Phase, Main Circuit Breaker Loadcenter, 40-Space, 40-Pole, Aluminum Bus, Cover: Surface/Flush with Door, NEMA 1- Indoor. - 39"H x 14.31"W x 3.88"D Does Not Contain Clearance Items 35

38 Loadcenters & Enclosures Cutler-Hammer - Loadcenters / Enclosures Loadcenters Type BR Main Lug 1-Phase Type BR Main Lug 1-Phase Eaton Cutler-Hammer Type BR Load Centers Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Features: Twin neutral design located in wireway, away from circuit breakers, means easier wiring and balancing of the load. Extra 1.5-inch knock-out for bundling allows maximum wiring gutter space for ease of wiring in compliance with NEC requirements. One-piece roll-formed metal backpan with circuit breaker alignment notches ensures accurately aligned breaker and bus tabs. Standard 14-3/8 inches (365.1 mm) wide enclosures fit snugly between wall studs. Tangential main knock-out eliminates the need for conduit offsets, which permits faster, easier installation. BR load centers feature Robertson slotted square combo screwheads, which means only one screwdriver is need for installation. Loadcenters & Enclosures C-HBR1224L125G C-HBR1224L125R C-HBR24L70RP C-HBR3040L200 C-HBR4040L200 C-HBR48L125RP C-HBR48L125SP C-HBR816L125FP C-HBR816L125RP 125 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 12-Space, 24-Pole, Aluminum Bus, Ground Bar, Cover: Surface/Flush with Door, NEMA 1- Indoor "H x 14.31"W x 3.88"D 125 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 12-Space, 24-Pole, Aluminum Bus, Cover: Surface/Flush with Door, NEMA 3R Rainproof "H x 14.31"W x 5.19"D 70 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 2-Space, 4-Pole, Aluminum Bus, Cover: Surface, NEMA 3R - Rainproof. Includes: Hub Closure Plate "H x 4.50"W x 3"D 200 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 30-Space, 40-Pole, Aluminum Bus, Cover: Surface/Flush with Door, NEMA 1- Indoor "H x 14.31"W x 3.88"D 200 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 40-Space, 40-Pole, Aluminum Bus, Cover: Surface/Flush with Door, NEMA 1- Indoor "H x 14.31"W x 3.88"D 125 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 4-Space, 8-Pole, Aluminum Bus, Cover: Surface, NEMA 3R - Rainproof. Includes: Hub Closure Plate. - 13"H x 11"W x 3.56"D 125 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 4-Space, 8-Pole, Aluminum Bus, Cover: Surface with No Door, NEMA 1- Indoor. - 13"H x 11"W x 3.56"D 125 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 8-Space, 16-Pole, Aluminum Bus, Feed thru Lugs, Current Design, Cover: Surface/Flush with Door, NEMA 1- Indoor - 13"H x 11"W x 3.56"D 125 AMP, 120/240V AC, 1-Phase, Main Lug Loadcenter, 8-Space, 16-Pole, Aluminum Bus, Feed thru Lugs, Current Design, Cover: Surface/Flush with Door, NEMA 3R Rainproof - 13"H x 11"W x 3.56"D Loadcenters Type BR Quick Connect Neutral Type BR Quick Connect Neutral Eaton Cutler-Hammer BR Quick Connect Neutral Loadcenters The Type BR Quick Connect Neutral loadcenters coupled with Type BR Quick Connect Neutral electronic breakers provide a clean, quick connection for an installer looking to save time while providing a professional look. C-HBR2448LQN125 C-HBR3060BQN100 C-HBR3060BQN150 C-HBR3060LQN125 C-HBR3060LQN200 C-HBR4080BQN AMP, 24-Space, 48 Circuit, Main Lug, BR Quick Connect Neutral Indoor Loadcenter, 80 Neutral Terminations, #6-2/0 Incoming Lug Size, w/ GBK14 Ground Bar - 23"H x 14.31"W x 3.88"D 100 AMP, 30-Space, 60 Circuit, BR Main Circuit Breaker 10kA/C incoming lug #4-1/0, Indoor BR Quick Connect Neutral Loadcenter Box Size D "H x 14.31"W x 3.88"D 150 Amp, 30-Space, 60-Circuit, Main Breaker, BR Quick Connect Neutral Indoor Loadcenter, 102 Neutral kcmil Incoming Lug Size "H x 14.31"W x 3.88"D 125 AMP, 30-Space, 60-Circuit, Main Lug, BR Quick Connect Neutral Indoor Loadcenter, 96 Neutral Terminations, #6-2/0 Incoming Lug Size, W/ GBK10 Ground Bar "H x 14.31"W x 3.88"D 200 AMP, 30-Space, 60 Circuit, Main LUG, BR Quick Connect Neutral Indoor Loadcenter, 96 Neutral Terminations, #1-300 kcmil Incoming Lug Size, W/ GBK1020 & GBK10 Ground Bar "H x 14.31"W x 3.88"D 200 AMP, 40-Space, 80 Circuit, CSR Main Circuit Breaker, 25kA/C incoming lug #2-300 kcmil, Indoor BR Quick Connect Neutral Loadcenter Box Size L1-39"H x 14.31"W x 3.88"D Does Not Contain Clearance Items 36

39 Loadcenters & Enclosures Cutler-Hammer - Loadcenters / Enclosures Loadcenters Type CH Main Breaker 1-Phase 1-Phase Main Circuit Breaker Loadcenter - Cutler-Hammer 1-Phase Main Circuit Breaker Loadcenter - Cutler-Hammer C-HCH14B100B 100A, 14-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D C-HCH14B100R 100A, 14-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 3R Enclosure "H x 14.31"W x 5.19"D C-HCH18B100C 100A, 18-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure - 21"H x 14.31"W x 3.88"D C-HCH18B100R 100A, 18-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 3R Enclosure - 21"H x 14.31"W x 5.19"D C-HCH22B100C 100A, 22-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure - 21"H x 14.31"W x 5.19"D C-HCH22B100R 100A, 22-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 3R Enclosure - 21"H x 14.31"W x 5.19"D C-HCH24B200E 200A, 24-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D C-HCH24B200R 200A, 24-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 3R Enclosure "H x 14.31"W x 5.19"D C-HCH30B100D 100A, 30-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D C-HCH32B150J 150A, 32-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D C-HCH32B200J 200A, 32-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D C-HCH42B200K 200A, 42-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure - 37"H x 14.31"W x 3.88"D C-HCH42B200R 200A, 42-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 3R Enclosure - 37"H x 14.31"W x 5.19"D C-HCH8B200RF 200A, 8-Pole, 1-Phase, Main Circuit Breaker Loadcenter, NEMA 3R Enclosure "H x 14.31"W x 5.19"D Loadcenters Type CH Main Breaker 1-Phase Plug-On Neutral 1-Phase Main Circuit Breaker - Type CH Plug-On Neutral - Cutler-Hammer Loadcenters & Enclosures Type CH Loadcenter - Plug-On Neutral Loadcenter Code changes and higher safety standards are leading to more arc fault and ground fault circuit interrupter installations. Eaton offers a unique product solution that enables a direct connection of the breaker to the neutral bar, eliminating the need for wiring a pigtail. Features and Benefits. Time savings up to 25% per AFCI/GFCI installation. Eliminates nuisance tripping due to loose pigtail connections. Clean gutter space. Easier troubleshooting due to less wiring. Backed by a limited lifetime warranty C-HCH42BPN200K C-HCH60BPN200N 200A, 42-Circuit, 42-Pole, 1-Phase, Box Size K, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure w/ Plug-On Neutral 200A, 60-Circuit, 60-Pole, 1-Phase, Box Size K, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure w/ Plug-On Neutral Loadcenters Type CH Main Breaker 3-Phase 3-Phase Main Circuit Breaker Loadcenter 3-Phase Main Circuit Breaker Loadcenter C-HCH30B3200R C-HCH42B3200L 200A, 30-Pole, 3-Phase, Main Circuit Breaker Loadcenter, NEMA 3R Enclosure - 39"H x 14.31"W x 5.19"D 200A, 42-Pole, 3-Phase, Main Circuit Breaker Loadcenter, NEMA 1 Enclosure - 39"H x 14.31"W x 3.88"D Does Not Contain Clearance Items 37

40 Loadcenters & Enclosures Cutler-Hammer - Loadcenters / Enclosures Loadcenters Type CH Main Lug 1-Phase 1-Phase Main Lug Loadcenter - Cutler-Hammer Type CH 1-Phase Main Lug Loadcenter - Cutler-Hammer Type CH Loadcenters & Enclosures C-HCH2L125RP 125A, 2-Space, 4-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enc "H x 4.5"W x 4.5"D C-HCH2L125SP 125A, 2-Space, 4-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enc "H x 6.88"W x 3.39"D C-HCH2L40RP 40A, 2-Space, 4-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enc "H x 4.5"W x 3.13"D C-HCH2L40SP 40A, 2-Space, 4-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enc "H x 4.5"W x 3.13"D C-HCH2L70RP 70A, 2-Space, 4-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enc "H x 4.5"W x 3.13"D C-HCH2L70SP 70A, 2-Space, 4-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enc "H x 4.5"W x 3.13"D C-HCH4L125RP 125A, 4-Space, 8-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enc. - 13"H x 11"W x 3.69"D C-HCH4L125SP 125A, 4-Space, 8-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enc. - 13"H x 11"W x 3.69"D C-HCH8L125RP 125A, 8-Space, 16-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enc. - 13"H x 11"W x 3.69"D C-HCH8L125SP 125A, 8-Space, 16-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enc. - 13"H x 11"W x 3.69"D Loadcenters Type CH Main Lug 1-Phase Twin Neutral 1-Phase Main Lug Loadcenter Cutler-Hammer Type CH Twin Neutral 1-Phase Main Lug Loadcenter Cutler-Hammer Type CH Twin Neutral C-HCH12L125B C-HCH12L125R C-HCH12L200R C-HCH16L125B C-HCH16L125R C-HCH20L125C C-HCH20L125R C-HCH24L125C C-HCH24L225R C-HCH32L225R C-HCH42L225G C-HCH42L225R 125A, 12-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D 125A, 12-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enclosure "H x 14.31"W x 5.19"D 200A, 12-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enclosure "H x 14.31"W x 5.19"D 125A, 16-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D 125A, 16-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enclosure "H x 14.31"W x 5.19"D 125A, 20-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enclosure - 21"H x 14.31"W x 3.88"D 125A, 20-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enclosure - 21"H x 14.31"W x 5.19"D 125A, 24-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enclosure - 21"H x 14.31"W x 3.88"D 225A, 24-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enclosure "H x 14.31"W x 5.19"D 225A, 32-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enclosure "H x 14.31"W x 5.19"D 225A, 42-Pole, 1-Phase, Main Lug Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D 225A, 42-Pole, 1-Phase, Main Lug Loadcenter, NEMA 3R Enclosure Does Not Contain Clearance Items 38

41 Loadcenters & Enclosures Cutler-Hammer - Loadcenters / Enclosures Loadcenters Type CH Main Lug 3-Phase 3-Phase Main Lug Loadcenter - Cutler-Hammer 3-Phase Main Lug Loadcenter - Cutler-Hammer C-HCH12L3125B 125A, 12-Pole, 3-Phase, Main Lug Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D C-HCH24L3125C 125A, 24-Pole, 3-Phase, Main Lug Loadcenter, NEMA 1 Enclosure - 21"H x 14.31"W x 3.88"D C-HCH24L3225R 225A, 24-Pole, 3-Phase, Main Lug Loadcenter, NEMA 3R Enclosure "H x 14.31"W x 5.19"D C-HCH42L3225G 225A, 42-Pole, 3-Phase, Main Lug Loadcenter, NEMA 1 Enclosure "H x 14.31"W x 3.88"D Type CH Loadcenter Covers Mechanical Interlock Covers - C-HCH8xM C-HCH8BSM C-HCH8CSM Mechanical Interlock Covers - C-HCH8xM Covers mechanicaly interlock two breakers. Type A covers interlock two CH breakers mounted across from one another. Type B covers interlock a main Type CSR Breaker with a Type CH Surface and Flush Covers - C-HCH8 Type A Mechanical Interlock Cover, Surface Mt., Fits CH12L125B, CH16L125B, CH12L3125B, CH14B100B Type A Mechanical Interlock Cover, Surface Mt., Fits CH20L125C, CH24L125C, CH18L3125C, CH24L3125C, CH22B100C, CH22N100C Loadcenters & Enclosures Type CH Indoor Loadcenter Covers - C-HCH8x Type CH indoor covers are ordered separately from loadcenters. Prefix F = Combination Flush/Surface Mount. Prefix S. Surface Mount.Box size is indicated in loadcenter catalog number C-HCH8BF C-HCH8BS C-HCH8CF C-HCH8CS C-HCH8DF C-HCH8DS C-HCH8ES C-HCH8GF C-HCH8GS C-HCH8JF C-HCH8JS C-HCH8KF C-HCH8KS C-HCH8LS C-HCH8NF Size B Combination Flush/Surface Cover for Size B CH Loadcenters 16.75"H x 14.31"W Size B Surface Cover for Size B CH Loadcenters 16.75" x 14.31"W Size C Combination Flush/Surface Cover for Size C CH Loadcenters 21"H x 14.31"W Size C Surface Cover for Size C CH Loadcenters 21"H x 14.31"W Size D Combination Flush/Surface Cover for Size D CH Loadcenters 29.13"H x 14.31"W Size D Surface Cover for Size D CH Loadcenters 29.13"H x 14.31"W Size E Surface Cover for Size E CH Loadcenters 29.13"H x 14.31"W Size G Combination Flush/Surface Cover for Size G CH Loadcenters 34.13"H x 14.31"W Size G Surface Cover for Size G CH Loadcenters 34.13"H x 14.31"W Size J Combination Flush/Surface Cover for Size J CH Loadcenters 34.13"H x 14.31"W Size J Surface Cover for Size J CH Loadcenters 34.13"H x 14.31"W Size K Combination Flush/Surface Cover for Size K Loadcenters 37"H x 14.31"W Size K Surface Cover for Size K CH Loadcenters 37"H x 14.31"W Type L Surface Cover for Size L CH Loacenters 39"H x 14.31"W Type N Combination Flush/Surface Cover for Loadcenter CH60BPN200N, NEMA 1, 45.25"H Does Not Contain Clearance Items 39

42 Loadcenters & Enclosures Intermatic - Loadcenters Intermatic T21004R Loadcenter INTT21004R Intermatic T21004R Control Panel Control panel features an all weather enclosure and contains a 4-circuit breaker base, an equipment grounding bar and a heavy duty, industrial grade T104M Mechanical Time Switch. Suitable for pool equipment control and for direct connection of underwater lights as well filter pumps, lights, ventilation systems, signs, air conditioners and heaters. Electrical ratings: Panel, 60 Amp, 120/240V or 120/208V single phase (3-wire) A.C. Clock supply VAC 50/60 Hz: 240. Switch: DPST. The circuit breaker base accepts interchangeable type breakers made by a number of different manufacturers. It has provisions to install switches or a GFCI receptacle on the side as well as the inside. The Time Switch can also accommodate an optional heater control (fireman) switch. 60A, Control Panel, 3R, 4-Position w/t104 Mechanical Time Switch Square D - Loadcenters / Enclosures Accessories Square D QO & Homeline Square D - Bolt-On Hubs - QO HUB Loadcenters & Enclosures QOHUB075 QOHUB100 QOHUB125 QOHUB150 QOHUB200 QOHUB250 QOHUB300 Bolt-On Hubs - QOHUBx Rainproof bolt-on hubs for use on NEMA 3R enclosures. "RB" devices will accept 3/4" through 2-1/2" bolt-on hubs without the use of reducers. Suffix "R" devices require 3" through 4" field cut opening. Hubs are suitable for use with conduit having ANSI standard taper pipe thread. 3/4" Conduit Size Bolt-On Hub, UL Listed For "RB" Suffix Devices 1" Conduit Size Bolt-On Hub, UL Listed For "RB" Suffix Devices 1-1/4" Conduit Size Bolt-On Hub, UL Listed For "RB" Suffix Devices 1-1/2" Conduit Size Bolt-On Hub, UL Listed For "RB" Suffix Devices 2" Conduit Size Bolt-On Hub, UL Listed For "RB" Suffix Devices 2-1/2" Conduit Size Bolt-On Hub, UL Listed For "RB" Suffix Devices 3" Conduit Size Bolt-On Hub, for "R" suffix devices, UL Listed for Mounting In Field Cut Opening Square D - Filler Plate - QOFP & HOMFP QO Load Center Filler Plate - QOFP Fills opening in covers if twistout is removed in error. QOFP QOHOMFP Load Center Filler Plate - Fills Opening In Covers If Twistout Is Removed In Error Load Center Filler Plate - Fills Opening In Covers If Twistout Is Removed In Error Square D - Generator CB Interlock Kit - QOCGK2C Generator Circuit Breaker Interlock Kit - QOCGK2 Designed for QO load centers only. Use on "G" and "S" Series NEMA 1 and "G" and "S1" Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker of a load center ( A) with a QO 2P (15-125A) branch circuit breaker. Includes a sliding mechanism that interlocks the main breaker with a branch circuit breaker, a retaining kit, instructions, mounting template and labeling. QOCGK2C Generator Circuit Breaker Interlock Kit (C at end = Clam Shell Pkg) Does Not Contain Clearance Items 40

43 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Accessories Square D QO & Homeline Square D - Handle Clamp - QO HLO1 Handle Clamp - QOHLO1 Clamp for holding QO or Q1 either 1, 2 or 3-Pole circuit breaker handles in ON or OFF Position. QOHLO1 Square D - Handle Clamp - QO1LO Handle Clamp for Holding QO or Q1 1, 2 or 3-Pole Breaker Handles In "ON" or "OFF" Position (not GFI) Circuit Breaker Handle Lock-Off - QO1LO Clamp for holding QO single-pole handle in "ON" or "OFF" position. For use with standard QO Circuit Breakers (1-Pole). QO1LO Square D - Handle Tie - QO1HT Handle Clamp for Holding QO 1-Pole Handle in "ON" or "OFF" Position Circuit Breaker Handle Tie - QO1HT Converts any two adjacent 120/240 Vac 1-pole QO circuit breakers to independent trip 2-Pole. For use with standard QO, QOB, or QOT Circuit Breakers (1-Pole). Loadcenters & Enclosures QO1HT Handle Tie for Converting any 2 QO or QOT Circuit Breakers (1-Pole) to Independent Trip 2-Pole Square D - Insulator Kit for Gr. Bars - QO PKGTAB Load Center Insulator Kit - QOPKGTAB Insulator kit for PK ground bars PK7GTA thru PK27GTA. Raises the PK ground bar 1.19" from the enclosure surface. QOPKGTAB Square D - Interlock Kits Ground Bar Insulator Kit For PK7GTA thru PK27GTA Homeline Generator Interlock Kit - QOHOMCGK For use on "S" Series NEMA 1 and "S1" Series NEMA 3R load centers. Interlocks a 2-pole, 15 Amp through 125 Amp branch breaker (back-fed from a generator) with the QOM1 - QOM2 2-pole main circuit breaker for a load center QOHOMCGK2C QOHOMCRBGK1C 125A - Homeline Generator Circuit Breaker Interlock Kit - QOM1 2P 125A - Homeline Generator Circuit Breaker Interlock Kit - QOM2 2P Does Not Contain Clearance Items 41

44 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Accessories Square D QO & Homeline Square D - Manual Transfer Equip. Kit QO QO Manual Transfer Equipment Kit PK4DTIM4HA Provides greater flexiblity to create back-up power panel up to 125A service, with a maximum of 42 circuit spaces. Load center main rating A maximum. Mounts on right side of QO single-phase A convertible main load center series S01 and S02. Retains two 2-pole QO breaker with a QO2DTI kit included for dual power supply applications. Includes mechanical interlock to prevent both main breakers being in the "ON" position at the same time. QOPK4DTIM4HA A QO Manual Transfer Equipment Kit, w/ Mech. Interlock & Retainer for Dual Power Supply Applications QOPK4DTIM4LA A QO Manual Transfer Equipment Kit, w/ Mech. Interlock & Retainer for Dual Power Supply Applications Square D - Mechanical Interlock - QO2DTI Loadcenters & Enclosures QO2DTI Mechanical Interlock Attachment - QO2DTI For interlocking the handles of two adjacent circuit breakers so that only one circuit breaker can be ON at a time. For use with QO and A1 standard circuit breakers. One circuit breaker must be a 2-Pole the other can be a 1 or 2-Pole. Mechanical Interlock, Interlocks Handles of QO Breakers so Only 1 Breaker can be "ON" at a Time (Not QOU) Square D - Mounting Base - QO N2L100N Mounting Base - QON2L100N Class 652 OEM Mounting Base. 100 Amp, 2 Space. QON2L100N QO & QOB OWM Plug-On Mounting Base - Class 652 Square D - Neutral/Ground Lug Kit - QO LK100AN Load Center Neutral/Ground Lug Kit - QOLK100AN Field installed for #6 to 2/0 AWG Al/Cu wire. Used as neutral/ground lugs for QO Load Centers and neutral lugs for Homeline Load Centers. The kit consists of the lug, wire binding screw, mounting screw and instructions for mounting. It is assembled and mounted in the field. QOLK100AN Square D - Padlock Attachment - PALA Load Center Neutral Ground Lug Kit, Field Installed, Wire Size #6 to 2/0 (Al/Cu) Square D - Circuit Breaker Handle Padlock Attachment - PALA Homeline circuit breaker handle padlock attachment for padlocking 2-pole 15 to 70A standard HOM circuit breakers in ON or OFF position QOHOM2PALA Handle Padlock Attachment, For 2P, Amp Homeline Circuit Breakers only Does Not Contain Clearance Items 42

45 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Accessories Square D QO & Homeline Square D - Padlock Attachment - QO1PA Circuit Breaker Padlock Attachment - QO1PA For padlocking circuit breaker in ON or OFF position. Fixed attachment. For use with QO Circuit Breakers (1-Pole). The padlock locks the bale in a position where the handle cannot operate. QO1PA Handle Padlock Attachment, Fixed, Padlocks 1P QO Breaker in "ON" or "OFF" Position Square D - PK Grounding Bar Kit - QO PK QOPK12GTA QOPK15GTA QOPK18GTA QOPK23GTA QOPK27GTA QOPK3GTA1 QOPK4GTA QOPK5GTA QOPK7GTA QOPK9GTA QOPKOGTA2 Grounding Bar Kits - QOPKx Equipment Ground Bar Assembly for QO and Homeline Load Centers. Field installable in all load centers. Suitable for copper or aluminum wire. All PK equipment grounding kits are supplied with mounting screws, necessary installation instructions, and an equipment Grounding Terminal self-adhesive label. UL Listed 12 Terminals, 4.70"L - PK Equipment Ground Bar Kit 15 Terminals, 5.63"L - PK Equipment Ground Bar Kit 18 Terminals, 6.56"L - PK Equipment Ground Bar Kit 23 Terminals, 8.11"L - PK Equipment Ground Bar Kit 27 Terminals, 9.36"L - PK Equipment Ground Bar Kit 3 Terminals, 1.38"L - PK Equipment Ground Bar Kit, One Mounting Hole 4 Terminals, 1.63"L, One Mounting Hole - PK Equipment Ground Bar Kit 5 Terminals, 2.25"L - PK Equipment Ground Bar Kit 7 Terminals, 2.88"L - PK Equipment Ground Bar Kit 9 Terminals, 3.78"L - PK Equipment Ground Bar Kit 2 Terminals, 1.75" L, One Mounting Hole Square D - Retaining Kit - QO HOM1RK Loadcenters & Enclosures Homeline Load Center Retaining Kit - QOHOM1RK Secures circuit breaker to interior when used as a back-fed main. For HOM612L100F/S, RB and HOM48L125GC, GRB load centers. QOHOM1RK Retaining Kit - Secures Circuit Breaker To Interior When Used As A Back-Fed Main Square D - Retaining Kit - QO HOM4RK2LA Homeline Retaining Kit - HOM4RK2LA Back-Fed Main Circuit Breaker Retaining Kits provide a cost-effective way to back feed a two-pole A circuit breaker on 8-40 circuit Homeline convertible main load centers. Load center mains rating: HOM A Maximum. Mounts on right side of Homeline single phase ampere convertible main load center Series S01 and S02. Retains one 2-pole Homeline breaker. QOHOM4RK2LA A Max. - Homeline Back-Fed Main Circuit Breaker Retaining Kit Does Not Contain Clearance Items 43

46 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Accessories Square D QO & Homeline Square D - Retaining Kit - QO PK1MB Retaining Kit - QOPK1MB Retaining Kit that is required for mounting assembly SK5669. SK5669 mounting assembly is used for replacing obsolete Q1 main circuit breaker in NQO panelboards to a QO main circuit breaker. QOPK1MB Square D - Retaining Kit - QO PK2MB Load Center Class 1130 Breaker Retaining Kit for NQO Type Panelboard Retaining Kit - QOPK2MB Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB, QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers. Loadcenters & Enclosures QOPK2MB Square D - Retaining Kit - QO PK3MB Retaining Kit Secures Circuit Breaker to Interior When Used as a Back-Fed Main Retaining Kit - QOPK3MB Secures 3P circuit breaker without accessories to left side of interior when used as a back-fed main. For 3 Phase Load Centers. QOPK3MB Retaining Kit for 3 Phase Load Ctrs., Secures Circuit Bkr. to Left Side of Interior When Used as a Back-Fed Main Square D - Retaining Kit - QO PK4MB2LA Retaining Kit - QOPK4MB2LA QO back-fed main circuit breaker retaining kit. Secures ONE 2-Pole QO circuit breaker with or without electrical accessories. Mounts on right side of QO single-phase ampere convertible main load center Series S01 and S02. Load Center Mains Rating: Qo A Maximum. QOPK4MB2LA Retaining Kit Secures 1 Circuit Breaker To Rt. Side of Interior When Used as a Back-Fed Main Square D - Secondary Surge Arrestor - QO HOM2175SB Homeline Secondary Surge Arrestor - QOHOM2175SB UL and C-UL listed secondary surge arresters and TVSS. Installs in Homeline load centers and combination service entrance devices. Designed for use on single-phase, three-wire 120/240 Vac, 50/60 Hz electrical service. LED indicates operational status. Quick plug-on installation. Max. Continuous Operating Voltage: 150 Vac max. phase-to-neutral. Max. surge current: 27,000 A per phase. QOHOM2175SB Homeline Secondary Surge Arrester and TVSS, 150 Vac Max Phase-to-Neutral Does Not Contain Clearance Items 44

47 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Accessories Square D QO & Homeline Square D - Secondary Surge Arrestor - QO2175SB QO Secondary Surge Arrestor - QO2175SB UL and C-UL listed secondary arresters and TVSS. Plugs on to the branch circuit spaces of the interior of a QO Load Center, NQO or NQOD Panelboard, or combination service entrance device (CSED) from Square D. Designed for use on single-phase, three-wire 120/240 Vac, 50/60 Hz electrical service. LED indicates operational status. Quick plug-on installation. Max. continuous operating voltage: 150 Vac max. phase-to-neutral. Max. surge current: 27,000 A per phase. QO2175SB QO Secondary Surge Arrester and TVSS, 150 Vac Max Phase to Neutral Square D - Service Entrance Barriers & Line Lug Cover - UL67 QOHJQLLC QOPKSB1HA QOPKSB1LA Square D - Service Entrance Barriers / Line Lug Cover - UL67 Enhanced safety and peace of mind for contractors. Simple, intuitive installation for a quick install with no tools required (convertible main LCs). Retrofitable to most existing load centers - can be applied to previous installs, upgrades, and existing inventory (convertible main LCs). Barriers can be easily installed after conductors are terminated so as not to impact common practice (convertible main LCs). One solution can be used across QO/HOM high amp load centers, and one across QO/HOM low amp load centers to reduce the total number of components. Robust material to ensure a reliable fit and function. CSED barriers come factory installed to minimize any impact to contractor installation or confusion. Complies with updated UL67 requirements per manufacturing date of January 1, Line Lug Cover Kit for Circuit Breaker H/J/Q Service Barrier Kit for ALL Convertible Load Centers Using QOM2 Main Breaker A, QOM1 Service Barrier Kit for ALL Convertible Load Centers Using QOM1 Main Breaker A, QOM1 Homeline Loadcenters - Main Circuit Breaker 100A, 12-Space - QO HOM1224M100PC Loadcenters & Enclosures Homeline Main Breaker Load Center - QOHOM1224M100PC Indoor convertible main breaker load center for plug-on neutral breakers. 100 Amp, 12-Space, 24-Circuit, 12 Tandem breakers max. Includes a fully distributed ground bar, allowing for the installation of Homeline Plug-on Neutral breakers on any space. Accommodates plug-on secondary surge arrestor (sold separately). Each pole space accepts full-size, tandem or quad breakers. Single phase. Rated 120/240 VAC and 22 ka short circuit current rating. Includes a combination flush/surface indoor cover. NEMA 1 indoor. UL listed for residential and commercial power distribution. QOHOM1224M100PC 100A, 12-Space, 24 Max 1-P Circuits, 12 Max Tandem, Homeline Load Center, Convertible Main Circuit Breaker, Plug-On Neutral Ready "H x 14.25"W x 3.75"D 100A, 20-Space - QO HOM2040M100PC Homeline Main Breaker Load Center - QOHOM2040M100PC Indoor convertible main breaker load center. 100A, 20-Space, 40-Circuit, 20-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers. Each pole accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 22,000 AIR short circuit rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commercial power distribution QOHOM2040M100PC 100A, 20-Space, 40 Max 1-P Circuits, 20 Max Tandem, Homeline Load Center, Convertible Main Breaker, Plug-On Neutral Ready "H x 14.25"H x 3.75"D Does Not Contain Clearance Items 45

48 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Main Circuit Breaker 100A, 24-Space - QO HOM2448M100PC Homeline Main Breaker Load Center - QOHOM2448M100PC Indoor convertible main breaker load center. 100A, 24-Space, 48-Circuit, 24-Tandem circuit breakers max. Includes a fully distributed neutral bar, allowing for installation of Homeline plug-on neutral breakers. Each pole space accepts full-size, tandem or quad breakers. 120/240 VAC, 22 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed. QOHOM2448M100PC QOHOM2448M100PV 100A, 24 Space, 48 Max 1-P Circuits, 24 Max Tandem, Convertible Main Breaker Homeline Load Center, Plug-On Neutral Ready "H x 14.25"W x 3.75"D 100A, 24 Space, 48 Max 1-P Circuits, 24 Max Tandem, Convertible Main Bkr. Homeline Load Center, Plug-On Neutral Ready VALUE PACK w/ (3) HOM120, (2) HOM230 Branch Cir. Bkrs "H x 14.25"W x 3.75"D 100A, 30-Space - QO HOM3060M100PC Loadcenters & Enclosures QOHOM3060M100PC Homeline Main Breaker Load Center - QOHOM3060M100PC Indoor convertible main breaker load center. 100A, 30-Space, 60-Circuit, 30-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers. Each pole accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 22 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commercial power distribution 100A, 30 Space, 60 Max 1-P Circuits, 30 Max Tandem, Convertible Main Breaker Homeline Load Center, Plug-on Neutral Ready "H x 14.25"W x 3.75"D 150A, 30-Space - QO HOM3060M150PC Homeline Main Breaker Load Center - QOHOM3060M150PC Indoor convertible main breaker load center. 150A, 30-Space, 60-Circuit, 30-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers. Each pole accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 22 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commercial power distribution. QOHOM3060M150PC QOHOM3060M150PV 150A, 30 Space, 60 Max 1-P Circuits, 30 Max Tandem, Convertible Main Breaker Homeline Load Center, Plug-on Neutral Ready "H x 14.25"W x 3.75"D 150A, 30 Space, 60 Max 1-P Circuits, 30 Max Tandem, Convertible Main Bkr. Homeline Load Center, Plug-on Neutral Ready VALUE PACK w/ (3)HOM120, (2) HOM230 Branch Cir. Bkrs "H x 14.25"W x 3.75"D 200A, 20-Space - QO HOM2040M200PC Homeline Main Breaker Load Center - QOHOM2040M200PC Indoor convertible main breaker load center. 200A, 20-Space, 40-Circuit, 20-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers. Each pole space accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 22,000 AIR short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commercial power distribution. QOHOM2040M200PC 200A, 20 Space, 40 Max 1-Pole Circuits, 20 Max Tandem, Homeline Load Center, Convertible Main Bkr, Plug-on Neutral Ready "H x 14.25"W x 3.75"D Does Not Contain Clearance Items 46

49 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Main Circuit Breaker 200A, 30-Space - QO HOM3060M200PC Homeline Main Breaker Load Center - QOHOM3060M200PC Indoor convertible main breaker load center. 200A, 30-Space, 60-Circuit, 30-Tandems max. Includes a fully distributed neutral bar allowing for the installation of Homeline plug-on neutral breakers. Each pole accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 22 ka short circuit current rating. Nema 1 indoor flush/surface cover included. UL listed for residential and commercial power distribution. QOHOM3060M200PC 200A, 30 Space, 60 Max 1-P Circuits, 30 Max Tandem, Convertible Main Breaker Homeline Load Center, Plug-on Neutral Ready "H x 14.25"W x 3.75"D 200A, 40-Space - QO HOM4080M200PC QOHOM4080M200PC QOHOM4080M200PV Homeline Main Breaker Load Center - QOHOM4080M200PC Indoor convertible main breaker load center. 200A, 40-Space, 80-Circuit, 40-Tandems max. Includes a fully distributed neutral bar allowing for the installation of Homeline plug-on neutral breakers. Each pole accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 22 ka short circuit current rating. Nema 1 indoor flush/surface cover included. UL listed for residential and commerical power distribution. 200A, 40 Space, 80 Max 1-P Circuits, 40 Max Tandem, Convertible Main Breaker Homeline Load Center, Plug-On Neutral Ready "H x 14.25"W x 3.75"D 200A, 40 Space, 80 Max 1-P Circuits, 40 Max Tandem, Convertible Main Bkr. Homeline Load Center, Plug-On Neutral Ready VALUE PACK w/ (3) HOM120, (2) HOM230 Branch Cir. Bkrs "H x 14.25"W x 3.75"D Homeline Loadcenters - Main Lugs 125A, 8-Space - QO HOM816L125PC Loadcenters & Enclosures Homeline Main Lug Load Center - QOHOM816L125PC Indoor convertible main lugs load center. 125A, 8-Space, 16-Circuit, 8-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers on any space. Each pole accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 10 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commmercial power distribution. QOHOM816L125PC 125A, 8 Space, 16 Max 1-P Circuits, 8 Max Tandem, Homeline Load Center, Convertible Main Lugs, Plug-On Neutral Ready " H X 14.25" W X 3.75" D 125A, 12-Space - QO HOM1224L125PC Homeline Main Lug Load Center - QOHOM1224L125PC Indoor convertible main lugs load center. 125A, 12-Space, 24-Circuits, 12-Tandems max. Single phase. Rated 120/240 VAC and 10 ka short circuit current rating. Each pole accepts full-size, tandem or quad breakers. Includes a fully distributed neutral bar, allowing for the installation of Homeline Plug-on Neutral Breakers on any space. NEMA 1 indoor. Combination flush/surface cover included. QOHOM1224L125PC 125A, 12 Space, 24 Max 1-P Circuits, 12 Max Tandem, Homeline Load Center, Convertible Main Lugs, Plug-On Neutral Ready " H X 14.25" W X 3.75" D Does Not Contain Clearance Items 47

50 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Main Lugs 125A, 12-Space - QO HOM1224L125PG Homeline Main Lug Load Center - QOHOM1224L125PG Indoor convertible main lugs load center with ground bar (PK15GTAL) for plug-on neutral breakers. 125 Amp, 12-Space, 24-Circuit,12-Tandem max. Includes a fully distributed ground bar, allowing for the installation of Homeline Plug-on Neutral breakers on any space. Each pole space accepts full-size, tandem or quad breakers. Single phase. Rated 120/240 VAC and 10 ka short circuit current rating. NEMA 1 indoor. Cover included. UL listed for residential and commercial power distribution. QOHOM1224L125PG 125A, 12 Space, 24 Max 1-P Circuits, 12 Max Tandem, Homeline Load Center w/ Ground Bar, Convertible Main Lugs, Plug-On Neutral Ready " H X 14.25" W X 3.75" D 125A, 16-Space - QO HOM1632L125PC Loadcenters & Enclosures QOHOM1632L125PC Homeline Main Lug Load Center - QOHOM1632L125PC Indoor convertible main lugs load center for plug-on neutral breakers. 125A, 16-Space, 32-Circuit, 16-Tandem circuit breakers max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers. Each pole accepts full-size or tandem or quad breakers. Single phase. 120/240 VAC and 10 ka short circuit current rating. NEMA 1 indoor flush/surface cover included. UL listed. 125A, 16-Space, 32 Max 1-P Circuits, 16 Max Tandem, Homeline Load Center Convertible Main Lugs, Plug-On Neutral Ready " H X 14.25" W X 3.75" D 125A, 20-Space - QO HOM2040L125PC Homeline Main Lug Load Center - QOHOM2040L125PC Indoor convertible main lugs load center. 125A, 20-Space, 40-Circuit, 20-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers. Each pole accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 10 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commercial power distribution. QOHOM2040L125PC 125A, 20-Space, 40 Max 1-P Circuits, 20 Max Tandem, Homeline Load Center, Convertible Main Lugs, Plug-On Neutral Ready " H X 14.25" W X 3.75" D 125A, 24-Space - QO HOM2448L125PG Homeline Main Lug Load Center - QOHOM2448L125PG Indoor convertible main lugs load center with cover and ground bar. 125A, 24-Space. 48-Circuit, 24-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral combination arc fault breakers on any space. Each pole space accepts full size, tandem or quad breakers. Single phase. Rated 120/240 Vac and 10 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commerical power distribution. QOHOM2448L125PG 125A, 24 Space, 48 Max 1-Pole Circuits, 24 Max Tandem, Homeline Main Lugs Load Ctr. w/ Cover & Ground Bar, Plug-on Neutral Ready " H X 14.25" W X 3.75" D Does Not Contain Clearance Items 48

51 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Main Lugs 125A, 24-Space - QO HOM2448L125PQ Homeline Main Lug Load Center - HOM2448L125PQ The Square D Homeline 125 Amp 24-Space 48-Circuit Indoor Convertible Main Lugs Load Center with cover for Plug-on Neutral breakers includes a ground bar and is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings. QOHOM2448L125PQ 125A, 24 Space, 48 Max 1-Pole Circuits, 24 Max Tandem, Homeline Main Lugs Load Ctr. w/ Cover & Ground Bar, Plug-on Neutral Ready, QWIK Grip " H X 14.25" W X 3.75" D Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Main Lugs 125A, 30-Space - QO HOM3060L125PQ QOHOM3060L125PQ Homeline Main Lug Load Center - QOHOM1224L125PC Indoor convertible main lugs load center with ground bar (PK15GTAL) for plug-on neutral breakers. 125 Amp, 30-Space, 60-Circuit, 30-Tandem max. Includes a fully distributed ground bar, allowing for the installation of Homeline Plug-on Neutral breakers on any space. Each pole space accepts full-size, tandem or quad breakers. Single phase. Rated 120/240 VAC and 10 ka short circuit current rating. NEMA 1 indoor. Cover included. UL listed for residential and commercial power distribution. 125A, 30 Space, 60 Max 1-Pole Circuits, 30 Max Tandem, Homeline Main Lugs Load Ctr. w/ Cover & Ground Bar, Plug-on Neutral Ready, QWIK Grip " H X 14.25" W X 3.75" D Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Main Lugs 200A, 40-Space - QO HOM4080M200PQ Loadcenters & Enclosures Homeline Main Lug Load Center - HOM4080M200PQC The Square D Homeline 200 Amp 40-Space 80-Circuit Indoor Convertible Main Breaker Qwik-Grip Load Center with cover for Plug-on Neutral breakers is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings. QOHOM4080M200PQ 200A, 40 Space, 80 Max 1-P Circuits, 40 Max Tandem, Homeline Main Lugs Load Center w/ Cover, Plug-On Neutral Ready, Qwik-Grip " H X 14.25" W X 3.75" D Does Not Contain Clearance Items 49

52 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Main Lugs 225A, 30-Space - QO HOM3060L225PC Homeline Main Lug Load Center - QOHOM3060L225PC Indoor convertible main lugs load center. 225A, 30-Space, 60-Circuit, 30 Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers on any space. Each pole accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 10 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commercial power distribution. QOHOM3060L225PC 225A, 30 Space, 60 Max 1-Pole Circuits, 30 Max Tandem, Homeline Main Lugs Load Ctr. w/ Cover, Plug-On Neutral Ready " H X 14.25" W X 3.75" D 225A, 30-Space - QO HOM3060L225PG Homeline Main Lug Load Center - QOHOM3060L225PG Indoor convertible main lugs load center with cover and ground bar kit (PK15GTAL & PK15GTA). 225A, 30-Space. 60- Circuit, 30-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers on any space. Each pole space accepts full size, tandem or quad breakers. Single phase. Rated 120/240 Vac and 10 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commerical power distribution. QOHOM3060L225PG 225A, 30 Space, 60 Max 1-Pole Circuits, 30 Max Tandem, Homeline Main Lugs Load Ctr. w/ Cover & Ground Bar, Plug-On Neutral Ready " H X 14.25" W X 3.75" D 225A, 40-Space - QO HOM4080L225PC Loadcenters & Enclosures QOHOM4080L225PC Homeline Main Lug Load Center - QOHOM4080L225PC Indoor convertible main lugs load center. 225A, 40-Space, 80-Circuit, 40-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline Plug-on neutral breakers on any space. Each pole accepts full-size, tandem or quad breakers. Rated 120/240 VAC and 10 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commercial power distribution. 225A, 40 Space, 80 Max 1-P Circuits, 40 Max Tandem, Homeline Main Lugs Load Center w/ Cover, Plug-On Neutral Ready " H X 14.25" W X 3.75" D Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Main Lugs 225A, 40-Space - QO HOM4080L225PQ Homeline Main Lug Load Center - HOM4080L225PQGC The Square D Homeline 200 Amp 40-Space 80-Circuit Indoor Convertible Main Lug Qwik-Grip Load Center with cover for Plug-on Neutral breakers includes 2 ground bars and is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings. QOHOM4080L225PQ 225A, 40 Space, 80 Max 1-P Circuits, 40 Max Tandem, Homeline Main Lugs Load Center w/ Cover, Plug-On Neutral Ready, Qwik-Grip " H X 14.25" W X 3.75" D Does Not Contain Clearance Items 50

53 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Main Lugs Fixed 100A, 6-Space - QO HOM612L100F/S Homeline Fixed Main Lugs Load Centers - QOHOM612L100F/S Ampere Rating: 100A. Main Type: Fixed - Factory installed main lugs. Phase: 1-Phase. Wiring Configuration: 3-Wire. Spaces: 6. Max single pole circuits: 12. Max tandem circuit breakers: 6. Short circuit current rating: 10kA. NEMA 1 indoor. Wire size: #8 to #1 AWG(Al/Cu). Cover type: Flush (without door) or Surface (without door) QOHOM612L100F QOHOM612L100S 70A, 2-Space - QO HOM24L70S 100A, 6 Space, 12 Max 1-Pole Circuits, 6 Max Tandem, Homeline Load Center w/ Fixed Main Lugs, Flush Device "H x 8.88"W x 3.8"D 100A, 6 Space, 12 Max 1-Pole Circuits, 6 Max Tandem, Homeline Load Center w/ Fixed Main Lugs, Surface Device "H x 8.88"W x 3.8"D Homeline Fixed Main Lugs Load Center - QOHOM24L70S Ampere Rating: 70A. Main Type: Fixed - Factory installed main lugs. Phase: 1-Phase. Wiring Configuration: 3-Wire. Spaces: 2. Max single pole circuits: 4. Max tandem circuit breakers: 2. Short circuit current rating: 10kA. NEMA 1 indoor. Wire size: #12 to #3 AWG(Al) - #14 to #4 AWG(Cu). Cover type: Surface (without door) QOHOM24L70S Homeline Loadcenters - Rainproof 70A, 2 Space, 4 Max 1-Pole Circuits, 2 Max Tandem, Homeline Load Center w/ Fixed Factory Installed Main Lugs - 9.3"H x 4.81"W x 3.19"D 100A, 12-Space Main Bkr - QO HOM1224M100PR QOHOM1224M100PR Homeline Rainproof Main Breaker Load Center - QOHOM1224M100PR Outdoor convertible main breaker load center for plug-on neutral breakers. 100 Amp, 12-Space, 24-Circuit, 12-Tandem circuits max. Includes a fully distributed neutral bar, allowing for the installation of Homeline Plug-on Neutral breakers on any space. Each pole space accepts full-size, tandem or quad breakers. Accommodates plug-on secondary surge arrestor (sold separately). Single Phase. Rated 120/240 VAC and 22 ka short circuit current rating. Rainproof cover features a stainless steel hasp that is easily padlocked. Nema 3R. UL listed for residential and commercial power distribution. 100A, 12-Space, 24 Max 1-P Circuits, 12 Max Tandem, Nema 3R Homeline Load Center, Convertible Main Breaker, Plug-on Neutral Ready "H x 14.75"W x 4.52"D 100A, 20-Space Main Bkr - QO HOM2040M100PR Loadcenters & Enclosures Homeline Rainproof Main Breaker Load Center - QOHOM2040M100PR Outdoor convertible main breaker load center for plug-on neutral breakers. 100A, 20-Space, 40-Circuit, 20-Tandem circuits. Includes a full disstributed neutral bar allowing for the installation of Homeline plug-on neutral breakers. Rated 120/240 VAC and 22,000 AIR short circuit current rating. Each pole accepts full-size, tandem or quad breakers. NEMA 3R outdoor surface mount. UL listed for residential and commercial power distribution. QOHOM2040M100PR 100A, 20 Space, 40 Max 1-Pole Circuits, 20 Max Tandem, Nema 3R Homeline Load Center, Convertible Main Bkrs, for Plug-on Neutral Bkrs "H x 14.75"W x 4.52"D Does Not Contain Clearance Items 51

54 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Rainproof 100A, 6-Space Main Lugs - QO HOM612L100RB Homeline Rainproof Fixed Main Lugs Load Center - QOHOM612L100RB Ampere Rating: 100A. Main Type: Fixed - Factory installed main lugs. Phase: 1-Phase. Wiring Configuration: 3-Wire. Spaces: 6. Max single pole circuits: 12. Max tandem circuit breakers: 6. Short circuit current rating: 10kA. NEMA 3R Outdoor/Rainproof. Wire size: #8 to #1 AWG(Al/Cu). Cover type: Combination Flush/Surface QOHOM612L100RB 100A, 6 Space, 12 Max 1-Pole Circuits, 6 Max Tandem, Nema 3R Homeline Load Center w/ Fixed Main Lugs "H x 8.88"W x 4.27"D 125A, 12-Space Main Lugs - QO HOM1224L125PR Homeline Rainproof Main Lug Load Center - QOHOM1224L125PR Outdoor convertible main lugs load center for plug on neutral breakers. 125A, 12-Space, 24-Circuit, 12 Tandem circuits max. Includes a fully distributed neutral bar allowing for the installation of Homeline Plug-on neutral breakers. Each pole accepts full-size, tandem or quad breakers. Single phase. 120/240 VAC 10 ka short circuit current rating. Cover included. NEMA 3R rainproof. QOHOM1224L125PR 125A, 12 Space, 24 Max 1-P Circuits, 12 Max Tandem, Nema 3R Homeline Load Center, Convertible Main Lugs, Plug-On Neutral Ready "H x 14.75"W x 4.52"D 125A, 16-Space Main Lugs - QO HOM816L125PRB Loadcenters & Enclosures Homeline Rainproof Convertible Main Breaker Load Center - QOHOM816L125PRB The Square D Homeline 125 Amp 8-Space 16-Circuit Outdoor Convertible Main Lugs Load Center for Plug-on Neutral breakers is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the valueminded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral combination arc fault breakers on any space. Each pole space accepts full-size, tandem or quad breakers. Ground and neutral bars accept up to (3) #10-14 equipment grounds. Includes a rainproof outdoor cover and is convertible to a main breaker load center with a QOM1 main breaker. Accommodates plug-on secondary surge arrestor (sold separately). Main feeders terminate from the top, feeders can enter from any direction, however, device cannot be rotated. Single phase. Rated 120/240 VAC and 10,000 AIR short circuit current rating. Rainproof cover features a stainless steel hasp that is easily padlocked for safety from theft. Designed with straight-in mains to save expensive cable and time. Distributed split branch neutral with terminal screws backed out offering with up to 50% more terminals than UL requires increases wiring flexibility saving installation time and simplifies wiring. Thermoplastic interior assembly is among the most rugged in the industry. Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque. For protection from damage or theft on the job site, interiors can be easily removed with a single captive screw. 3 ground bar mounting locations (left, right and end) let you pick the easiest spot to wire. Made in the USA QOHOM816L125PRB 125A, 8 Spaces, 16 Max 1-Pole Circuits, 8 Max Tandem, Nema 3R Homeline Load Center, Convertible Main Lugs, Plug-On Neutral Ready 125A, 20-Space Main Lugs - QO HOM2040L125PR Homeline Rainproof Main Lug Load Center - QOHOM2040L125PR Outdoor convertible main lugs load center for plug on neutral breakers. 125A, 20-Space, 40-Circuit, 20-Tandem circuits. Includes a fully distributed neutral bar allowing for the installations of Homeline plug-on neutral breakers. Rated 120/240 VAC and 10 ka short circuit current rating. Single Phase. Each pole accepts full-size, tandem or quad breakers. NEMA 3R outdoor surface mount. UL listed for residential and commercial power distribution. QOHOM2040L125PR 125A, 20-Space, 40 Max 1-P Circuits, 20 Max Tandem, Nema 3R Homeline Load Center, Convertible Main Lugs, Plug-on Neutral Ready "H x 14.75"W x 4.52"D Does Not Contain Clearance Items 52

55 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Homeline Loadcenters - Rainproof 200A, 8-Space Main Bkr - QO HOM816M200PFT Homeline Rainproof Main Breaker Load Center - QOHOM816M200PFT Outdoor convertible main circuit breaker load center with feed-thru lugs for plug on neutral breakers. 200A, 8-Space, 16- Circuit, 8-Tandems max. Includes fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral breakers on any space. Each pole accepts full-size, tandem or quad breakers. Single phase. Rated 120/240 VAC and 22 ka short circuit current rating. Nema 3R outdoor. Rainproof cover with hasp that is easily padlocked. UL listed for residential and commercial power distribution. QOHOM816M200PFT 200A, 8 Space, 16 Max 1-P Circuits, 8 Max Tandem, Nema 3R Convertible Main Breaker Homeline Load Center w/ Feed-Thru Lugs, Plug-On Neutral Ready "H x 14.75"W x 4.52"D 70A, 2-Space Main Lugs - QO HOM24L70RB Homeline Rainproof Fixed Main Lugs Load Center - QOHOM24L70RB Ampere Rating: 70A. Main Type: Fixed - Factory installed main lugs. Phase: 1-Phase. Wiring Configuration: 3-Wire. Spaces: 2. Max single pole circuits: 4. Max tandem circuit breakers: 2. Short circuit current rating: 10kA. NEMA 3R Outdoor/Rainproof. Wire size: #12 to #3 AWG(Al) - #14 to #4 AWG(Cu). Cover type: Flush/Surface QOHOM24L70RB 70A, 2-Space, 4 Max 1-Pole Circuits, 2 Max Tandem, Nema 3R Homeline Load Center w/ Fixed Main Lugs "H x 4.88"W x 4"D Homeline Loadcenters - Value Packs 100A, 20-Space Value Pk - QO HOM2040M100VP QOHOM2040M100VP Homeline Main Breaker Load Center Value Pack - QOHOM2040M100VP Indoor convertible main breaker load center for plug-on neutral breakers. 100A, 20-Space, 40-Circuit, 20-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral combination arc fault breakers on any space. Each pole space accepts full-size, tandem or quad breakers. Includes (2) HOM120 Homeline 20A single-pole circuit breakers, and (1) HOM230 Homeline 30A double-pole circuit breaker. Rated 120/240 VAC and 22,000 AIR short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commercial power distribution. 100A, 20 Space, 40 Max 1-P Circuits, 20 Max Tandem, Homeline Load Center Value Pack, Convertible Main Bkr, Plug-On Neutral Ready "H x 14.25"H x 3.75"D 200A, 30-Space Value Pk - QO HOM3060M200VP Homeline Main Breaker Load Center Value Pack - QOHOM3060M200VP Indoor convertible main breaker load center for plug-on neutral breakers. Value pack contains complete load center (box, interior and cover) with selected branch circut breakers. 200A, 30-Space, 60-Circuit, 30-Tandems max. Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral circuit breakers on any space. Each pole space accepts full-size, tandem or quad breakers. Includes (3) HOM120 Homeline 20A single-pole circuit breakers and (2) HOM230 Homeline 30A double-pole circuit breakers. Rated 120/240 VAC and 22 ka short circuit current rating. Nema 1 indoor. Flush/surface cover included. UL listed for residential and commercial power distribution. Loadcenters & Enclosures QOHOM3060M200VP 200A, 30-Space, 60 Max 1-P Circuits, 30 Max Tandem, Homeline Load Center Value Pack, Convertible Main Bkr, Plug-On Neutral Ready "H x 14.25"W x 3.75"D Does Not Contain Clearance Items 53

56 Loadcenters & Enclosures Square D - Loadcenters / Enclosures QO Loadcenters Square D - QO Convertible Main Breaker Indoor 1-PH Square D - QO 1-Phase Indoor Main Circuit Breaker Loadcenters QO Load Centers, 1-Phase, 120/240 Vac. Convertible mains, factory-installed main circuit breaker. 22 ka short circuit current rating. NEMA 1 indoor enclosure. Convertible to main lugs or lower amperage main circuit breaker. Copper Bus. Order ground bar kit and indoor cover with door separately. Includes Load Center Box and Interior. Order QO, QOT, QO- EDP, QO-GFI, QO-AFI and QO-PL branch circuit breakers. 100A to 125A has QOM1 main circuit breaker frame size. 150A to 225A has QOM2 main circuit breaker frame size. QO112M100 QO116M100 QO12040M200 QO120M100 QO124M100 QO130M150 QO130M200 QO132M100 QO14060M200 QO140M200 QO140M A Load Center, 1-PH 3-Wire, 120/240Vac, 12-Space, 12 1-Pole Circuits, Wire Size #6 to 1 AWG/kcmil Al/Cu 100A Load Center, 1-PH 3-Wire, 120/240Vac, 16-Space, 16 1-Pole Circuits, Wire Size #6 to 1 AWG/kcmil Al/Cu 200A Load Center, 1-PH 3-Wire, 120/240Vac, 20-Space, 40 1-Pole Circuits, 20 Tandem Bkrs., Wire Size #4 to 250 AWG/kcmil Al/Cu 100A Load Center, 1-PH 3-Wire, 120/240Vac, 20-Space, 20 1-Pole Circuits, Wire Size #6 to 1 AWG/kcmil Al/Cu 100A Load Center, 1-PH 3-Wire, 120/240Vac, 24-Space, 24 1-Pole Circuits, Wire Size #6 to 2/0 AWG/kcmil Al/Cu 150A Load Center, 1-PH 3-Wire, 120/240Vac, 30-Space, 30 1-Pole Circuits, Wire Size #4 to 250 AWG/kcmil Al/Cu 200A Load Center, 1-PH 3-Wire, 120/240Vac, 30-Space, 30 1-Pole Circuits, Wire Size #4 to 250 AWG/kcmil Al/Cu 100A Load Center, 1-PH 3-Wire, 120/240Vac, 32 Space, 32 1-Pole Circuits, Wire Size #6 to 2/0 AWG/kcmil Al/Cu 200A Load Center, 1-PH 3-Wire, 120/240Vac, 40-Space, 60 1-Pole Circuits, 20 Tandem Bkrs., Wire Size #4 to 250 AWG/kcmil Al/Cu 200A Load Center, 1-PH 3-Wire, 120/240Vac, 40-Space, 40 1-Pole Circuits, Wire Size #4 to 250 AWG/kcmil Al/Cu 225A Load Center, 1-PH 3-Wire, 120/240Vac, 40-Space, 40 1-Pole Circuits, Wire Size #4 to 300 AWG/kcmil Al/Cu Square D - QO Convertible Main Breaker Indoor 3-PH Loadcenters & Enclosures QO327M100 QO330MQ150 QO342MQ200 Square D - QO 3-Phase Indoor Main Circuit Breaker Loadcenters QO Load Centers, 3-Phase, Nema 1 indoor enclosure. Convertible mains, factory-installed QDL main circuit breaker. Copper Bus. 25kA short circuit current rating. Voltage rating: 208Y/120 Vac - 240/120 Vac Delta Vac Delta. Order equipment ground bar kit and indoor cover with door separately. Includes load center box and interior. Order QO, QO- GFI, QO-AFI, QO-PL branch circuit breakers. 100A Load Center, 3-PH 4-Wire, 27 Max. 1-Pole QO Breakers, Includes QO3100VH Main Bkr., Wire Size #4 to 2/0 AWG/kcmil Al/Cu 150A Load Center, 3-PH 4 Wire, 30 Max. 1-Pole QO Breakers, Wire Size #4 to 300 AWG/kcmil Al/Cu 200A Load Center, 3-PH 4 Wire, 42 Max. 1-Pole QO Breakers, Wire Size #4 to 300 AWG/kcmil Al/Cu Square D - QO Convertible Main Breaker Outdoor 1-PH Square D - QO 1-Phase Outdoor Main Breaker Load Centers QO Load Centers, 1-Phase, 3-Wire, 120/240 Vac. Convertible mains, factory-installed main circuit breaker. 22kA short circuit current rating. NEMA 3R outdoor/rainproof enclosure w/ cover. Convertible to main lugs or lower amperage main circuit breaker. Copper Bus. Order ground bar kit separately. Order QO, QOT, QO-GFI, QO-AFI, QO-EPD and QO-PL branch circuit breakers. 100A to 125A has QOM1 main circuit breaker frame size. 150A to 225A has QOM2 main circuit breaker frame size. QO112M100RB QO12040M200RB QO120M100RB QO130M200RB QO140M200RB QO1816M200FTRB 100A Load Center, Convertible MB, 1-PH, NEMA 3R, 12-Space, 12 1-Pole Circuits, Wire: #6 to 2/0 AWG(Al/Cu) 200A Load Center, Convertible MB, 1-PH, NEMA 3R, 20-Space, 40 1-Pole Circuits, 20 Tandem, Wire: #4 to 250 AWG/kcmil (Al/Cu) 100A Load Center, Convertible MB, 1-PH, NEMA 3R, 20-Space, 20 1-Pole Circuits, Wire: #6 to 2/0 AWG(Al/Cu) 200A Load Center, Convertible MB, 1-PH, NEMA 3R, 30-Space, 30 1-Pole Circuits, Wire: #4 to 250 AWG/kcmil (Al/Cu) 200A Load Center, Convertible MB, 1-PH, NEMA 3R, 40-Space, 40 1-Pole Circuits, Wire: #4 to 250 AWG/kcmil (Al/Cu) 200A Load Center, Convertible MB, 1-PH, NEMA 3R, 8-Space, 16 1-Pole Circuits, 8 Tandem, Feed-Thru Lugs, Wire: #4 to 4/0 AWG(Al/Cu) Does Not Contain Clearance Items 54

57 Loadcenters & Enclosures Square D - Loadcenters / Enclosures QO Loadcenters Square D - QO Convertible Main Breaker Outdoor 3-PH Square D - QO 3-Phase Outdoor Main Breaker Load Center QO Load Centers, 3-Phase, 3 or 4-Wire. Rain-tight bolted (RB) hub. Rated operational voltage: 240 V delta AC, 240/120 V delta AC, 208Y/120 V AC. Convertible Mains (breaker). Electrical Connection: Lugs. NEMA 3R outdoor protection. Surface cover. Tin plated copper busbar. Order grounding bar separtely. UL Listed. QO330MQ200RB 200A Load Center, Convertible MB, 3-PH, NEMA 3R, 30-Space, 30 Circuit, Wire: #4 to 300 AWG/kcmil (Al/Cu) Square D - QO Convertible Main Lug Indoor 1-PH Square D - QO 1-Phase Main Lug Load Centers QO Load Centers, 1-Phase, 120/240 Vac. Convertible mains, factory-installed main lugs. 65 ka short circuit current rating. NEMA 1 indoor enclosure. Convertible to main circuit breaker. Copper Bus. Order indoor cover with door separately. Includes load center box, interior and grounding bar. Order QO, QOT, OQ-EPD, QO-GFI, QO-AFI and QO-PL branch circuit breakers. 125A has QOM1 Main Frame Size. 150A to 225A has QOM2 Main Frame Size. QO11224L125G QO112L125G QO116L125G QO120L125G QO124L125G QO130L150G QO130L200G QO132L125G QO142L225G 125A Load Center, Main Lugs, 1-PH 3-Wire, 120/240Vac, 12-Space, 24 1-Pole Circuits, 12 Tandem, #6 to 2/0 AWG(Al/Cu), w/ground Bar 125A Load Center, Main Lugs, 1-PH 3-Wire, 120/240Vac, 12-Space, 12 1-Pole Circuits, #6 to 2/0 AWG(Al/Cu), w/ground Bar 125A Load Center, Main Lugs, 1-PH 3-Wire, 120/240Vac, 16-Space, 16 1-Pole Circuits, #6 to 2/0 AWG(Al/Cu), w/ground Bar 125A Load Center, Main Lugs, 1-PH 3-Wire, 120/240Vac, 20-Space, 20 1-Pole Circuits, #6 to 2/0 AWG/kcmil Al/Cu, w/ground Bar 125A Load Center, Main Lugs, 1-PH 3-Wire, 120/240Vac, 24-Space, 24 1-Pole Circuits, #6 to 2/0 AWG/kcmil Al/Cu, w/ground Bar 150A Load Center, Main Lugs, 1-PH 3-Wire, 120/240Vac, 30-Space, 30 1-Pole Circuits, #6 to 250 AWG/kcmil Al/Cu, w/ground Bar 200A Load Center, Main Lugs, 1-PH 3-Wire, 120/240Vac, 30-Space, 30 1-Pole Circuits, #6 to 250 AWG/kcmil Al/Cu, w/ground Bar 125A Load Center, Main Lugs, 1-PH 3-Wire, 120/240Vac, 32-Space, 32 1-Pole Circuits, #6 to 250 AWG/kcmil Al/Cu, w/ground Bar 225A Load Center, Main Lugs, 1-PH 3-Wire, 120/240Vac, 42-Space, 42 1-Pole Circuits, #6 to 300 AWG/kcmil Al/Cu, w/ground Bar Square D - QO Convertible Main Lug Outdoor 1-PH Square D - QO 1-Phase Outdoor Main Lug Load Centers QO Load Centers, 1-Phase, 3-Wire, 120/240 Vac. Convertible mains, factory installed main lugs. 65kA short circuit current rating. NEMA 3R outdoor/rainproof enclosure w/ cover. Convertible to main circuit breaker. Copper Bus. Grounding bar included. Order QO, QOT, QO-GFI, QO-EPD, QO-AFI and QO-PL branch circuit breakers. 125A has QOM1 main circuit breaker frame size. 150A to 225A has QOM2 main circuit breaker frame size. Loadcenters & Enclosures QO112L125GRB QO112L200GRB QO124L125GRB 125A Load Center, Convertible Mains, Lug, NEMA 3R, 12-Space, 12 1-Pole Circuits, Wire: #6 to 2/0 AWG(Al/Cu) 200A Load Center, Convertible Mains, Lug, NEMA 3R, 12 Space, 12 1-Pole Circuits, Wire: #6 to 2/0 AWG(Al/Cu) 125A Load Center, Convertible Mains, Lug, NEMA 3R, 24 Space, 24 1-Pole Circuits, Wire: #6 to 2/0 AWG(Al/Cu) Does Not Contain Clearance Items 55

58 Loadcenters & Enclosures Square D - Loadcenters / Enclosures QO Loadcenters Square D - QO Fixed Main Lug Indoor 1-PH Square D - QO Load Center, 1-Phase Fixed Mains - Lugs QO Load Centers, 1-Phase, 3-Wire, 120/240 Vac. Fixed Mains - factory installed main lugs. 10kA short circuit current rating. NEMA 1 indoor enclosure. Tin Plated Copper Bus. Order cover and ground bar kit separately unless noted in individual descriptions. Order QO, QOT, QO-EPD, QO-GFI, QO-AFI, and QO-PL branch circuit breakers. Loadcenters & Enclosures QO148L125GS QO24L70F QO24L70S QO2L30S QO612L100DF QO612L100DS QO612L100F QO612L100S QO816L100DF QO816L100DS QO816L100S 125A Load Center, Fixed Main Lugs, 1-PH, 4-Space, 8 1-Pole Circuits, 4 Tandem, Wire: 12-2/0 Al /0 Cu AWG, Surface Cover No Door, w/ Ground Bar 70A Load Center, Fixed Main Lugs, 1-PH, 2-Space, 4 1-Pole Circuits, 2 Tandem, Wire: #12-3 AWG(Al) #14-4 AWG(Cu), Flush Cover No Door, Order Ground Bar Separately 70A Load Center, Fixed Main Lugs, 1-PH, 2-Space, 4 1-Pole Circuits, 2 Tandem, Wire:#12-3 AWG(Al) #14-4 AWG(Cu), Surface Cover No Door, Order Ground Bar Separately 30A Load Center, Fixed Main Lugs, 1-PH, 2-Space, 2 1-Pole Circuits, Wire: #12-3 AWG(Al) #14-4 AWG(Cu), Surface Cover No Door, Order Ground Bar Separately 100A Load Center, Fixed Main Lugs, 1-PH, 6-Space, 12 1-Pole Circuits, 6 Tandem, Wire: #8-1 AWG Al/Cu, Flush Cover w/ Door, Order Ground Bar Separately 100A Load Center, Fixed Main Lugs, 1-PH, 6-Space, 12 1-Pole Circuits, 6 Tandem, Wire: #8-1 AWG(Al/Cu), Surface Cover w/ Door, Order Ground Bar Separately 100A Load Center, Fixed Main Lugs, 1-PH, 6-Space, 12 1-Pole Circuits, 6 Tandem, Wire: #8-1 AWG(Al/Cu), Flush Cover No Door, Order Ground Bar Separately 100A Load Center, Fixed Main Lugs, 1-PH, 6-Space, 12 1-Pole Circuits, 6 Tandem, Wire: #8-1 AWG(Al/Cu), Surface Cover No Door, Order Ground Bar Separately 100A Load Center, Fixed Main Lugs, 1-PH, 8-Space, 16 1-Pole Circuits, 8 Tandem, Wire: #8-1 AWG(Al/Cu), Flush Cover w/ Door, Order Ground Bar Separately 100A Load Center, Fixed Main Lugs, 1-PH, 8-Space, 16 1-Pole Circuits, 8 Tandem, Wire: #8-1 AWG(Al/Cu), Surface Cover w/ Door, Order Ground Bar Separately 100A Load Center, Fixed Main Lugs, 1-PH, 8-Space, 16 1-Pole Circuits, 8 Tandem, Wire: #8-1 AWG(Al/Cu), Surface Cover No Door, Order Ground Bar Separately Square D - QO Fixed Main Lug Indoor 3-PH QO312L125G QO320L125G QO324L125G QO330L200G QO342L225G QO403L60NS Square D - QO Load Center - 3-Phase Fixed Mains - Lugs QO Load Centers, 3-Phase 4W 208Y/120 Vac, 3-Phase 4W 240/120 Vac Delta and 3-Phase 3W 240 Vac Delta. Fixed Mains - Factory installed main lugs. 65kA short circuit current rating. NEMA 1 indoor enclosure. Tin Plated Copper Bus. Order cover and ground bar kit separately unless noted in individual descriptions. Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers. 125A Load Center, Fixed Main Lugs, 3-PH, 12-Space, 12 1-Pole Circuits, Wire #6 to 2/0 AWG(Al/Cu), w/ Ground Bar, Order Cover Separately 125A Load Center, Fixed Main Lugs, 3-PH, 20-Space, 20 1-Pole Circuits, Wire #6 to 2/0 AWG(Al/Cu), w/ Ground Bar, Order Cover Separately 125A Load Center, Fixed Main Lugs, 3-PH, 24-Space, 24 1-Pole Circuits, Wire #6 to 2/0 AWG(Al/Cu), w/ Ground Bar, Order Cover Separately 200A Load Center, Fixed Main Lugs, 3-PH, 30-Space, 30 1-Pole Circuits, Wire #6 to 250 AWG/kcmil(Al/Cu), w/ Ground Bar, Order Cover Separately 225A Load Center, Fixed Main Lugs, 3-PH, 42-Space, 42 1-Pole Circuits, Wire #6 to 300 AWG/kcmil(Al/Cu), w/ Ground Bar, Order Cover Separately 60A Load Center, Fixed Main Lugs, 3-PH, 3-Space, 3 1-Pole Circuits, Wire #10 to 6 AWG (Cu), w/ Surface Cover No Door, Neutral Installed Does Not Contain Clearance Items 56

59 Loadcenters & Enclosures Square D - Loadcenters / Enclosures QO Loadcenters Square D - QO Fixed Main Lug Outdoor 1-PH Square D - QO 1-Phase Outdoor Main Lugs Load Centers QO Load Centers, 1-Phase, 3-Wire, 120/240 Vac. Fixed mains, factory installed main lugs. 10kA short circuit current rating. NEMA 3R outdoor/rainproof enclosure w/ cover. Copper Bus. Order QO, QOT, QO-GFI, QO-EDP, QO-AFI and QO-PL branch circuit breakers. QO148L125GRB QO24L70RB QO612L100RB QO816L100RB 125A Load Center, Fixed Main Lugs, NEMA 3R, 1PH, 4-Space, 8 1-Pole Circuits, 4 Tandem, Wire: #12-2/0 AWG(Al) #14-2/0 AWG(Cu) 70A Load Center, Fixed Main Lugs, NEMA 3R, 1PH, 2-Space, 4 1-Pole Circuits, 2 Tandem, Wire: #12-3 AWG(Al) #14-4 AWG(Cu) 100A Load Center, Fixed Main Lugs, NEMA 3R, 1PH, 6-Space, 12 1-Pole Circuits, 6 Tandem, Wire: #8 to 1 AWG(Al/Cu) 100A Load Center, Fixed Main Lugs, NEMA 3R, 1PH, 8-Space, 16 1-Pole Circuits, 8 Tandem, Wire: #8 to 1 AWG(Al/Cu) Square D - QO Fixed Main Lug Outdoor 3-PH Square D - QO 3-Phase Outdoor Main Lug Load Center QO Load Centers, 3-Phase, 4-Wire, 208Y/120 Vac; 3-Phase, 4-Wire 240/120 Vac Delta and 3-Phase 3-Wire 240 Vac Delta. Fixed Mains, factory-installed main lugs. Copper Bus. 65kA short circuit current rating. NEMA 3R outdoor/rainproof enclosure. Grounding bar included. Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers. QO312L125GRB QO330L200GRB 125A Load Center, Fixed Main Lugs, NEMA 3R, 3PH, 12-Space,12 1-Pole Circuits, Wire: #6 to 2/0 AWG(Al/Cu) 200A Load Center, Fixed Main Lugs, NEMA 3R, 3PH, 30-Space, 30 Circuits, Wire: #6 to 300 AWG/kcmil (Al/Cu) Square D - QO Generator Main Panel QO48M-DSGP QO48M30DSGP QO48M60DSGP Square D - QO48M DSGP QO Load Center, Fixed Mains Breaker Generator Panel, Single Phase-Three Wire. Max voltage rating 120/240Vac. Total number of spaces 4. Maximum single pole breakers 8. Maximum tandem breakers 4. RMS short circuit rating Max wire size #14-8 / #8-2 AWG/kcmil Al/Cu. Does not accept feed-thru lug kit. Includes box, surface cover and door. 30A 1-Phase, 3-Wire Generator Panel, Main Wire Size #14-8 AWG Al/Cu 60A 1-Phase, 3-Wire Generator Panel, Main Wire Size #8-2 AWG Al/Cu Square D - QO Indoor Covers with Door Loadcenters & Enclosures Square D - Indoor QO Covers Available in flush or surface configurations to meet any mounting situation. All covers feature a floating, spring-mounted trim which provides automatic flush adjustment. This ensures proper alignment without manual adjustment and speeds final installation. QOC12UF QOC12US QOC16UF QOC16US Flush Mount Indoor Cover w/ Door for 12 Space QO Load Center Convertible Mains Breaker Surface Mount Indoor Cover w/ Door for 12 Space QO Load Center Convertible Mains Breaker Flush Mount Indoor Cover w/ Door for 12 Space QO Load Center Convertible or Fixed Mains Lug Surface Mount Indoor Cover w/ Door for 12 Space QO Load Center Convertible or Fixed Mains Lug Does Not Contain Clearance Items 57

60 Loadcenters & Enclosures Square D - Loadcenters / Enclosures QO Loadcenters Square D - QO Indoor Covers with Door QOC20U100F QOC20U100S QOC24UF QOC24US QOC30UF QOC30US QOC32UF QOC342MQF QOC342MQS QOC40UF QOC40US QOC42UF QOC42US QOC54UF Flush Mount Indoor Cover w/ Door for 16 to 20 Space QO Load Center Convertible Mains Breaker Surface Mount Indoor Cover w/ Door for 16 to 20 Space QO Load Center Convertible Mains Breaker Flush Mount Indoor Cover w/ Door for 16 to 30 Space QO Load Center Fixed Mains Lug, Convertable Mains Lug & Breaker Surface Mount Indoor Cover w/ Door for 16 to 30 Space QO Load Center Fixed Mains Lug, Convertable Mains Lug & Breaker Flush Mount Indoor Cover w/ Door for 12 to 30 Space QO Load Center Fixed Mains Lug, Convertable Mains Lug & Breaker Surface Mount Indoor Cover w/ Door for 12 to 30 Space QO Load Center Fixed Mains Lug, Convertable Mains Lug & Breaker Flush Mount Indoor Cover w/ Door for 32 Space QO Load Center Convertible Mains Breaker Flush Mount Indoor Cover w/ Door for 3-Phase Load Center Main Breaker Surface Mount Indoor Cover w/ Door for 3-Phase Load Center Main Breaker Flush Mount Indoor Cover w/ Door for 12 to 42 Circuit QO Load Center Surface Mount Indoor Cover w/ Door for 12 to 42 Circuit QO Load Center Flush Mount Indoor Cover w/ Door for 12 to 42 Circuit QO Load Center Surface Mount Indoor Cover w/ Door for 12 to 42 Circuit QO Load Center Flush Mount Indoor Cover w/ Door for 54-Space Load Centers Square D - QO Plug-On Neutral Breaker Loadcenters Square D QO Plug-On Neutral Load Centers Engineered to accept PoN CAFI circuit breakers for a quick plug-on neutral connection on every circuit. Installing QO Plugon Neutral CAFI Circuit Breakers eliminates the pigtail connection, clearing the wire gutter and speeding up the job. The mounting rail of plug-on neutral load center is engineered with a plated neutral bar that accepts all QO Circuit Breakers and is similar to the thermoplastic rail of standard QO load centers, but allows for the Plug-on Neutral CAFI Circuit Breakers to be connected on any circuit. Single phase only. Use standard flush or surface mount covers (purchase separately). Accepts both QO PoN and pigtail CAFI Circuit Breakers, and all QO Circuit Breakers and QO accessories. Loadcenters & Enclosures QO124L125PG QO124L125PQG QO124M100P QO130L125PQG QO130L200PQG QO130M200PQ QO142L225PQG QO142M200P QO142M200PQ QO154L225PG QO154M200P 125A, 24 Space, 1-P Circuits, 24 Max Tandem, Indoor Plug-On Neutral Load Center Box & Interior, Main Lugs, Convertible 125A, 24 Space, 1-P Circuits, 24 Max Tandem, Indoor Plug-on Neutral Load Centers w/ Qwik-Grip, Main Lugs, Convertible 100A, 24 Space, 1-P Circuits, 24 Max Tandem, Indoor Plug-On Neutral Load Center Box & Interior, Main Circuit Breaker, Convertible 125A, 30 Space, 1-P Circuits, 30 Max Tandem, Indoor Plug-on Neutral Load Centers w/ Qwik-Grip, Main Lugs, Convertible 200A, 30 Space, 1-P Circuits, 30 Max Tandem, Indoor Plug-on Neutral Load Centers w/ Qwik-Grip, Main Lugs, Convertible 200A, 30 Space, 1-P Circuits, 30 Max Tandem, Indoor Plug-on Neutral Load Centers w/ Qwik-Grip, Main Breaker, Convertible 225A, 42 Space, 1-P Circuits, 42 Max Tandem, Indoor Plug-on Neutral Load Centers w/ Qwik-Grip, Main Lugs, Convertible 200A, 42 Space, 1-P Circuits, 42 Max Tandem, Indoor Plug-On Neutral Load Center Box & Interior, Main Lugs, Convertible 200A, 42 Space, 1-P Circuits, 42 Max Tandem, Indoor Plug-on Neutral Load Centers w/ Qwik-Grip, Main Lugs, Convertible 225A, 54 Space, 1-P Circuits, 54 Max Tandem, Indoor Plug-on Neutral Load Center Box & Interior, Main Lugs, Convertible 200A, 54 Space, 1-P Circuits, 54 Max Tandem, Indoor Plug-on Neutral Load Center Box & Interior, Main Circuit Breakers, Convertible Does Not Contain Clearance Items 58

61 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Square D - NEMA Enclosures 100A, 1-3P, NEMA 1 - QO FA100S Circuit Breaker Enclosure - FA100S Surface mount Nema 1 enclosure only for molded case circuit breakers. Circuit breaker prefixes: FAL, FHL, FCL (order separately) Rating: A. Poles: 1, 2, 3 QOFA100S 100A, 2P, NEMA 1 - QO 2100BNF/S NEMA 1 Enclosure Only for 100A max. Circuit Breakers, 1-3 Poles, Circuit Breaker Types FAL, FHL, FCL Circuit Breaker Enclosures - QO2100BNF & QO2100BNS NEMA 1 type general purpose enclosures. Service: 120/240 Vac. 100A rating, 2-Pole. Circuit breakers: QO, QO-PL, QO- GFI (10,000 AIR); QO-VH (22,000 AIR). Order circuit breakers separately. Order equipment ground bar PKOGTA2, if required. Not for use with one pole QO circuit breakers QO2100BNF QO2100BNS 100A, 2P, NEMA 3R - QO 2100BNRB NEMA 1 Flush Enclosure Only for 100A max Circuit Breakers, 2-Pole, Breaker Type QO NEMA 1 Surface Enclosure Only for 100A max Circuit Breakers, 2-Pole, Breaker Type QO Circuit Breaker Enclosure - QO2100BNRB NEMA type 3R rainproof enclosure. Service: 120/240 Vac. 100A Rating, 2-Pole. Circuit Breakers: QO, QO-PL, QO-GFI (10,000 AIR); QO-VH (22,000 AIR). Order circuit breakers separately. Order equipment ground bar PKOGTA2, if required. Not for use with one pole QO circuit breakers QO2100BNRB NEMA 3R Enclosure Only for 100A Circuit Breakers, 2-Pole, Breaker type QO 100A, 2P, NEMA 3R & Bkr. - QO 2100NRBCP Circuit Breaker Enclosure w/ Circuit Bkr. NEMA type 3R top feed rainproof enclosure. Service: 120/240 Vac. Maximum. Single phase, 3-wire, 2-pole, solid neutral. Includes factory installed 100A. 2-pole QO circuit breaker, will take QO or QO GFCI circuit breakers. For use as main breaker or service disconnect, as service entrance equipment when used with ground bar. Order equipment ground bar PKOGTA2, if required. Box dimensions: 6.92" x 13.18" x 4.12". UL listed. Loadcenters & Enclosures QO2100NRBCP 100A, 3P, NEMA 1 - QO 3100BNS NEMA 3R Enclosure w/ 100A 2P QO Breaker, 1-Phase, 2P 3W, Circuit Breaker Types QO or QO GFCI Circuit Breaker Enclosure - QO3100BNS NEMA 1 general purpose enclosure. Service 240 Vac. 100A Rating, 3-Pole. Circuit Breakers: QO, QO-PL, QO-GFI (10,000 AIR); QO-VH (22,000 AIR). Order circuit breakers separately. Order equipment ground bar PKOGTA2, if required. Not for use with one pole QO circuit breakers. QO3100BNS NEMA 1 Surface Enclosure Only for 100A Circuit Breakers, 3-Pole, Breaker Type QO Does Not Contain Clearance Items 59

62 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Square D - NEMA Enclosures 100A, 3P, NEMA 3R - QO 3100BNRB Circuit Breaker Enclosure - QO3100BNRB NEMA type 3R rainproof enclosure. Service 240 Vac. 100A Rating, 3-Pole. Circuit Breakers: QO, QO-PL, QO-GFI (10,000 AIR); QO-VH (22,000 AIR). Order circuit breakers separately. Order equipment ground bar PKOGTA2, if required. Not for use with one pole QO circuit breakers. QO3100BNRB 200A, 2P, NEMA 1 - QO Q22200NS NEMA 3R Enclosure Only for 100A max. Circuit Breakers, 3-Pole, Breaker Type QO Circuit Breaker Enclosure - QOQ22200NS Q Frame Enclosure only, accepts 200A max. 2P Q Frame circuit breakers. Type 1 General Purpose surface mount. Service: 2P, 240 Vac maximum. Circuit breaker prefixes QBL, QDL, QGL, QJL (order separately). Includes factoryinstalled groundable neutral assembly; (2) ground lugs and (2) neutral lugs and equipment ground kit PKOGTA2. QOQ22200NS 200A, 2P, NEMA 3R - QO Q22200NRB NEMA 1 Enclosure Only for 200A, 2-Pole Circuit Breakers, Circuit Breaker Types QBL, QDL, QGL, QJL Circuit Breaker Enclosure - QOQ22200NRB Q Frame Enclosure only, accepts 200A max. 2P Q Frame circuit breakers. Type 3R rainproof. Service: 2P, 240Vac maximum. Circuit breaker prefixes QBL, QDL, QGL and QJL (order separately). Includes factory-installed groundable neutral assembly; (2) ground lugs and (2) neutral lugs and equipment ground kit PKOGTA2. Loadcenters & Enclosures QOQ22200NRB 225A, 2-P NEMA 1 - QO M22225N NEMA 3R Enclosure Only for 200A, 2-Pole Circuit Breakers, Circuit Breaker Types QBL, QDL, QGL, QJL Circuit Breaker Enclosures - QOM22225N NEMA 1 type QOM2 general purpose enclosures. Service: 2P 240 VAC maximum. Ampere rating: 100A to 225A. Circuit Breakers: QOM2, 22k AIR (order separately). Equipment ground bar PKOGTA2 factory-included. QOM22225NS 225A, 2-P NEMA 3R - QO M22225NRB NEMA 1 Surface Mount Enclosure Only for 225A max. Circuit Breakers, 2-Pole, for Molded Case Breakers Type QOM2 Circuit Breaker Enclosure - QOM22225NRB NEMA 3R rainproof QOM2 enclosure only. Service: 2P 240 Vac maximum. Ampere rating: 100A to 225A. Circuit Breakers: QOM2, 22k AIR (order separately). Equipment ground bar PKOGTA2 factory-included. QOM22225NRB NEMA 3R Enclosure Only for 225A max. Circuit Breakers, 2-Pole, Molded Case Breaker Type QOM2 Does Not Contain Clearance Items 60

63 Loadcenters & Enclosures Square D - Loadcenters / Enclosures Square D - NEMA Enclosures 225A, 3P, NEMA 1 - QO Q23225NS Circuit Breaker Enclosure - QOQ23225NS Q Frame Enclosure only, accepts 225A max. 3P Q Frame circuit breakers. Type 1 General Purpose surface mount. Service: 3P, 240 Vac. Circuit breaker prefixes QBL, QDL, QGL, QJL (order separately). Includes factory-installed groundable neutral assembly; (2) ground lugs and (2) neutral lugs and equipment ground kit PKOGTA2. QOQ23225NS 225A, 3P, NEMA 3R - QO Q23225NRB NEMA 1 Enclosure Only for 225A, 3-Pole Circuit Breakers, Circuit Breaker Types QBL, QDL, QGL, QJL Circuit Breaker Enclosure - QOQ23225NRB Q Frame Enclosure only, accepts 225A max. 3P Q Frame circuit breakers. Type 3R rainproof. Service: 3P, 240 Vac. Circuit breaker prefixes QBL, QDL, QGL, QJL (order separately). Includes factory-installed groundable neutral assembly; (2) ground lugs and (2) neutral lugs and equipment ground kit PKOGTA2. QOQ23225NRB 250A, 2-3P, NEMA 1 - QO J250S NEMA 3R Enclosure Only for 225A, 3 Pole Circuit Breakers, Circuit Breaker Types QBL, QDL, QGL, QJL Circuit Breaker Enclosure - QOJ250S NEMA 1 surface mount enclosure only for molded case circuit breakers. Circuit breakers: H Frame; HDL, HGL, HJL, HLL 15A - 150A rating 2-3 Poles. J Frame; JDL,JGL, JJL, JLL A rating 2-3 Poles. Accepts standard rated 80% breakers, not rated at 100%. Maximum short circuit rating is 25 kair, 600 Vac; 65 kair. Earth Leakage Module is not compatible with these enclosures. QOJ250S 400A, 2-3P, NEMA 1 - QO LA400S NEMA 1 Enclosure Only for 250A max. Circuit Breakers, 2-3 Poles, Breaker Types H & J Frame Circuit Breaker Enclosure - QOLA400S NEMA 1 surface mount enclosure only for molded case circuit breakers. Circuit Breakers: LAL, LHL, Q4L, KAL, KHL (not included). Rating: A. Poles: 2 or 3. Loadcenters & Enclosures QOLA400S NEMA 1 Enclosure Only for 400A max, Circuit Breakers, 2-3 Poles, Breaker Types LAL, LHL, Q4L, KAL, KHL Does Not Contain Clearance Items 61

64 Metering Equipment AC Hour Meters Aclaras Smart Grid Meter - GE Electric 727X Aclara I-210+ Electric Meter w/ Smart Grid Functionality The I-210+, Aclara's single phase basic energy meter, offers utilities high quality, solid-state measurement performance, affordability, accuracy and reliability. The I-210+ measures energy, and with the addition of a soft switch, is compatible with a suite of third-party AMR solutions. The I210+ features an optional integrated, factory-installed remote disconnect switch to help utilities efficiently address non-payments and move-in, move-outs. Highly Accurate Measurements: Typically measured at +/- 0.2 percent, the Aclara I-210 family of meters provides best-in-class accuracy, combined with the low starting watts to metered value and measured electricity usage. Broad Communications Support: The I-210 family allows for the interchangeability of AMR/AMI modules and covers the broadest range of possible AMI communication technologies including RF mesh, cellular, power line and Ethernet. Billing and Smart Applications: Utilities can save energy, lower costs, and defer additional transmission and generation expenses with the ability to shave peak load, shape load and curtail load to mitigate grid events. Additionally, consumers can conserve energy and shift energy use for time-of use or time-based rate structures offering customer savings from 5 to 15 percent of their monthly electricity use. Load Management: The I-210+ is equipped with a fully rated 200A service switch; this meter platform provides basic load management functionality. Additional features and options include: Remote disconnect: The disconnect switch is fully integrated inside the I Network Applications: The I-210+ is available in 12S and 25S forms for network applications. Four options for Energy Accumulation. Additional functionality and flexibility provided by soft switch a software application to enable the meter with additional functionality. Soft switch can be loaded onto the meter at the time of order or after the meter has been put in service. IEEE Reliability Data-This is an option that can be added via the V2 soft switch and allows the utility to directly measure and monitor quality of service provided to the customer. A patented firmware algorithm to detect tamper-by-meter inversion (turning the meter upside down). GEE727X Splash Proof Kit - RDC Aclara's Smart Grid Meter I-210+, 1-PH,,120/240V Splash Proof Kit for Hour Meters - Redington Heavy duty splash proof kit. Fits Redington Model 710 Electromechanical Hour Meter RDC Ammeters Heavy Duty Splash Proof Kit, fits Model 710 Electromechanical Hour Meter Metering Equipment AC Ammeter - Yokogawa AM Ammeters YOK250340PDPD YOK7507Z YOK8507Z 80 Amp AC Ammeter, 3.5", Self Contained w/external Magnetic Shield 80A, AC Ammeter, 3.5", Self Contained Does Not Contain Clearance Items 62

65 Metering Equipment Ammeters Current Transformer - Yokogawa 2RL800 Current Transformer Generally for Ammeter use only. Current Ratio: 80:5. Frequency: Hz. Window diameter: 1.05". Insulation level: 600 Volts, 10 kv BIL full wave. Flexible leads are UL C, CSA approved, #16 AWG, 24" long. Terminals are brass studs No UNC with one flat washer, lockwasher and regular nut. YOK2RL800 Current Transformer, 80.5 Current Ratio Current Transformer Cabinets Milbank - Current-Transformer Cabinets Current Transformer Rated Cabinet C-T Cabinets MIL363612LC3RWB NEMA 3R Continuous Hinge Current Transformer Enclosure, 36 X 36 X 12 MIL484812CT3RWB NEMA 3R Transformer Cabinet, Wood Back, 48 X 48 X 12 MILU5990O NEMA 3R Current Transformer Cabinet for First Energy, 50M AIC, 36 X 36 X 10 Meter Equipment - Cutler-Hammer Meter Mains Single Phase UHTR Devices - Eaton Meter Sockets 1-Phase UHTR Devices Single Meter Socket - C-HUHTR Residential service, single position, 3-wire, ringless type cover, meter socket. 600VAC maximum. Jaws: 4. Service: OH. Bypass: Horn. Line connections: #8-2/0. Load connections: #8-2/0. 3-5/16" hub opening. One-piece die-run enclosure C-HUHTRS101BE C-HUHTRS202BCH C-HUHTRS213CE C-HUHTRS223ACH 125A Single Meter Socket, Residential Ringless Type Cover, 1-Phase, 3-Wire, Horn Bypass "H x 8.22"W x 3.61"D 200A Single Meter Socket, Residential Ringless Type Cover, 1-Phase, 3-Wire, Horn Bypass - 14"H x 8"W x 4.38"D 200A Single Meter Socket, Residential Ringless Type Cover, 1-Phase, 3-Wire, Horn Bypass - 15"H x 11"W x 4.38"D 200A Single Meter Socket, Residential Ringless Type Cover, 1-Phase, 3-Wire, Horn Bypass - 13"H x 13"W x 4.94"D Metering Equipment Does Not Contain Clearance Items 63

66 Metering Equipment Meter Equipment - Cutler-Hammer Meter Sockets Single Phase Non-EUSERC Devices - Eaton Meter Mains 1-Phase Non-EUSERC Devices C-HCMB1212B200B C-HCMB88B200BTS C-HCMBE24L125BT C-HMBB200BTSC Eaton Cutler-Hammer Single Phase Non-EUSERC Meter Breakers Eaton is proud to introduce a new line of Cutler-Hammer West Coast/EUSERC Meter Breaker units. The new EUSERC devices complement the existing standard meter breaker devices. Features: Single-phase, 3-wire, 120/240 volt, 10,000 AIC. Larger 300 kcmil lugs and additional knockouts for ease of installation. Box type main lugs are included. Factory installed neutrals. Hub provisions on top endwall. If hubs are required, order "DS" type hubs. Ring type sockets are provided with a sealing ring. Padlockable device covers provide an additional measure of security, and help prevent tampering. Most units have center keyhole for easy one-person installation. Clip-Tight socket has reduced connections. This offers fewer hot spots and improves socket integrity. NEMA 3R rainproof construction. Metering Accessories - Eaton 200A - Ringless, All-In-One Meter Breaker w/ Distribution Section, 1-PH, 3-Wire, OH/UG, 12 Circuit /8" H X 14-7/16" W X 5-3/8" D 200A - Ring Style, All-In-One Meter Breaker w/ Distribution Section, 1-PH, 3-Wire, OH/UG, 8 Circuit /8" H X 14-7/16" W X 5-3/8" D 125A - Ring Style Meter Main, No Distribution, 1-PH, 3-Wire, OH/UG, 2/4 Distribution /8" H X 14-7/16" W X 5-3/8" D 200A - Ringless, Meter Main, No Distribution, 1-PH, 3-Wire, OH/UG /4" H X 14-7/16" W X 5-3/8" D Meter Socket Access. Cutler-Hammer ARP Cutler-Hammer Meter Socket Accessories. C-HARP00002CHB Small Hub Closure Plate C-HARP00004CH12 1-1/4" Hub C-HARP00006CH2 2" Hub, Small Opening C-HARP00017CH2 2" Hub, Large Opening C-HARP00019CH3 3" Hub, Large Opening C-HARP00035CHJ Replacement - Plug-in Fifth Terminal (R & RS Models Only) Interlock Switch & Cover - Cutler-Hammer MBDF1M Metering Equipment C-HMBDF1M Cutler-Hammer MBDF1M Generator interlock switch and cover for meter main combos. Generator Interlock Switch and Cover for Meter Main Combos Does Not Contain Clearance Items 64

67 Metering Equipment Meter Mains & Sockets - Milbank Meter Mains Single Phase - Milbank Milbank Meter Mains Single Phase Milbank Single Position Sockets 4 Terminal MILU3491XL200 MILU3989XL MILU4835X2200BL MILU5168XTL100 MILU5168XTL A, 4-Term, 1-Phase/3-Wire, Ringless 120/240V, w/uqfb-200-xi Breaker, Meter-Main Meter Socket - 4-1/8" D X 12" W X 29" H 125A, 4-Term, 1-Phase/3-Wire, Ringless 120/240V, 2-P Breaker Required, Meter-Main Meter Socket - 3-3/4" D X 11" W X 22" H 320A, 4-Term, 1-Phase/3-Wire, Ringless, 120/240V Meter Main with Breakers - 5-3/4" D X 25" W X 30" H 100A, 4-Term, 1-Phase/3-Wire, Vertical, Meter Main w/ Load Center, 10 Circuit Interior, 120/240V - 4-1/2" D X 14-1/8" W X 32" H 200A, 4-Term, 1-Phase/3-Wire, 8 Circuit Interior, 120/240V, Ringless Meter Main - 4-1/2" D X 14-1/8" W X 32" H Milbank - Meter Sockets 1-Phase Multi-Gang Milbank U1232R, U1233R, U1234R & U1252RRL 150 & 200 Amp. 4 Termimal, Ringless 1o3W, 300VAC, OH/UG. Bussing is 5/16" x 1" aluminum on the 2 and 3 gang series. On the 4-6 gangs the bussing is 3/8" x 1" aluminum. MILU1232R MILU1233R MILU1234R MILU1252RRL MILU1252RRLBLG MILU2854X MILU2856X 150A - 4-Term, 2 Gang/Position, 1-Phase / 3-Wire, Horizontal Gangs Meter Socket, Ringless, 300V - 5-1/8" D X 26-1/2" W X 14" H 150A - 4-Term, 3 Gang/Position, 1-Phase / 3-Wire, Horizontal Gangs Meter Socket, Ringless, 300V - 5-1/8" D X 34-11/16" W X 14" H 150A - 4-Term, 4 Gang/Position, 1-Phase / 3-Wire, Horizontal Gangs Meter Socket, Ringless, 300V - 5-1/8" D X 42-7/8" W X 16" H 200A - 4-Term, 2 Gang/Position, 1-Phase / 3-Wire, Horizontal Gangs Meter Socket, Ringless, 300V - 5-1/8" D X 26-1/2" W X 14" H 200A - 4-Term, 2 Gang/Position, 1-Phase / 3-Wire, Horizontal Gangs Meter Socket, Ringless, 300V, Barrel Lock / Guard Provision - 5-1/8"D X 26-1/2" W X 14" H 125A - 4-Term, 4 Gang/Position, 1-Phase / 3-Wire, Horizontal Gangs Meter Socket, Ringless, 240V, Large Closing Plate - 4-7/8" D X 31" W X 25" H 125A - 4-Term, 6 Gang/Position, 1-Phase / 3-Wire, Horizontal Gangs Meter Socket, Ringless, 240V, Large Closing Plate - 4-7/8" D X 31" W X 37" H Milbank - Meter Sockets Lever Bypass 1-Phase Milbank Meter Sockets LEVER Bypass 1-Phase Metering Equipment MILU1079R MILU1129O MILU3278RL MILU4905XBLG 320A Continuous 400A Max, 4 Term, 1PH/3W, Lever Bypass, Ringless 600VAC Meter Socket - 4-7/8"D x 13"W x 38-3/4"H 320A Continuous 400A Max, 4 Term, 1PH/3W, Lever Bypass, Ringless 600VAC Meter Socket - 4-7/8"D x 15"W x 30"H 200A 4-Term. 1-Position, 1PH/3W OH Small Hub, 600VAC, Ringless, Lever Bypass, Meter Socket - 4-1/8"D x 11"W x 15-1/2"H 320A Continuous 400A Max, 4-Term, 1PH/3W, Lever Bypass, Side Wireway, 600VAC Meter Socket "AEP", Barrell Lock/Guard Provision - 5-3/4"D x 16"W x 38-3/4"H Does Not Contain Clearance Items 65

68 Metering Equipment Meter Mains & Sockets - Milbank Milbank - Meter Sockets Lever Bypass 3-Phase Milbank Meter Sockets Lever Bypass 3-Phase MILU2594X MILU2594XBLG MILU9551RL MILU9701RL MILU9701RLBLG 320A 7-Term, 3-PH 4-Wire, Single Position Meter Socket, Ringless, Side Wireway - 6-1/2"D x 19"W x 34-1/8"H 320A 7-Term. 1-Position, 3PH/4W OH/UG, Large Closing Plate, 600VAC, Ringless, Side Wireway Lever Bypass, Barrell Lock/Guard Provision, Meter Socket - 6-1/2"D x 19"W x 34-1/8"H 200A 5-Term. 1-Position 1PH/3W or 3PH/3W, OH/UG, Small Hub, 600VAC, Ringless, Jaw Clamping, 600VAC, Lever Bypass, Meter Socket - 4-7/8"D x 13"W x 19"H 200A 7-Term. 1-Position, 3PH/4W OH/UG, Small Hub, 600VAC, Ringless, Jaw Clamping, 600VAC Lever Bypass, Meter Socket - 4-7/8"D x 13"W x 19"H 200A 7-Term. 1-Position, 3PH/4W OH/UG, Small Hub, Ringless, Jaw Clamping, 600VAC Lever Bypass, Meter Socket, Barrell Lock / Guard Provision - 4-7/8"D x 13"W x 19"H Milbank - Meter Sockets Single Phase Milbank Single-Position Meter Sockets Amp 4 Termainl Ringless 600 VAC Metering Equipment MILU1980OKK MILU1980OKKBLG MILU3938O MILU4433X MILU4532XL MILU7021RLTG MILU7040OTG MILU7040RLTG MILU7040RLTGBLG MILU7487RLTG MILU7487RLTGBLG MILU7487YLTG 200A, 600VAC, 1-Position, 4 Term, Ringless, Horn-Bypass, 1-PH 3-Wire, Side Wireway, NEMA 3R, Hub Type Blank - 4-1/2"D x 13"W x 15-1/4"H 200A, 600VAC, 1-Position, 4 Term, Ringless, Horn-Bypass, 1-PH 3-Wire, Side Wireway, NEMA 3R, Hub-Blank, Barrell Lock/Guard Provision - 4-1/2"D x 13"W x 15-1/4"H 200A 4-Term. 1 Phase, Ringless, Side Wireway, Meter Socket - 4-1/2"D x 13"W x 15-1/4"H 320A 4-Term. 1-Position, 1PH/3W & 3PH/4W, OH/UG, Ringless, Side Wireway Metering Socket - 4-7/8"D x 15"W x 31-1/2"H 200A 4 Term. 1-Position 1PH/3W, OH/UG Ringless, 600VAC,Dbl. Lug, Meter Socket - 4-7/8"D x 15"W x 20-1/2"H 200A 4-Term. 1-Position 1PH/3W, Ringless, 600VAC Meter Socket "AEP" - 4-1/8"D x 8"W x 15-1/2"H 200A 4-Term. 1-Position 1PH/3W, OH/UG Ringless, 600VAC, Meter Socket - 4-1/8"D x 11"W x 14-5/8"H 200A 4-Term. 1-Position 1PH/3W, OH/UG Ringless, 600VAC, Meter Socket - 4-1/8"D x 11"W x 14-5/8"H 200A 4-Term. 1-Position 1PH/3W, OH/UG Ringless, 600VAC, Meter Socket, Barrell Lock / Guard Provision - 4-1/8"D x 11"W x 14-5/8"H 125A 4-Term. 1-Position, 1PH/3W, OH/UH, Small Hub, 600VAC, Ringless w/kk-horn Type Bypass, Meter Socket - 3-5/16"D x 8"W x 11-1/2"H 125A 4-Term. 1-Position, 1PH/3W, OH/UH, Small Hub, 600VAC, Ringless w/kk-horn Type Bypass, Meter Socket, Barrell Lock / Guard Positions - 3-5/16"D x 8"W x 11-1/2"H 125A 4-Term. 1-Position, 1PH/3W, OH/UG, Plain Top, 600VAC, Ringless, w/1-1/4" Hub Opening, Meter Socket - 3-5/16"D x 8"W x 11-1/2"H Does Not Contain Clearance Items 66

69 Metering Equipment Metering Equipment - Square D Lexan Meter Socket Cover - QO Square D Lexan Cover Plate Lexan meter socket cover plate for ring and ringless type meter mains and ring and ringless type all-in-ones QO29007 LEXAN Meter Socket Cover Plate MPR Meter-Pak Meter Centers - QOMPR Square D - MPR Meter-Pak Meter Centers Ringless Type, with 5-Jaw meter sockets, no bypass, Meter-Pak Meter Centers. Consult local utility for approval before installation. 120/240 Vac 1 Phase 3 Wire. UL Listed NEMA 3R construction. Suitable only for use as service equipment. Swingable mounting feet supplied at bottom of device. Surface mount, convertible to semi-flush with field installed flange kit. Provisions for mounting 2-pole circuit breaker for each meter socket position (order circuit breakers separately) Combination overhead/underground feed QOMPR22125 Ringless Meter Main - QO RC200S 125A per Position, 2-Position, MPR Meter-Pak Meter Center, Ringless Square D - RC200S Meter Main 200A meter socket, ringless surface-mount combination service entrance device. Service: OH/UG. 22kA short circuit current rating. Service Disconnect: one 2-Pole 200A (order separately). Rainproof, NEMA 3R enclosure. Enclosure dimensions: 18.50" H x 19.65" W x 6.0"D QORC200S 200A Ringless Meter Main Socket, Surface Mount Tenant Circuit Breaker - QOM2200MM QOM2200MM Square D - QOM2200MM Tenant Circuit Breaker 200A Tenant Miniature Circuit Breaker. 10,000 AIR 120/240 VAC. For use in 200 A Max. type MP, MPR and MPH Meter- Pak metering equipment 200A Tenant Circuit Breaker, 10,000 AIR Metering Equipment Does Not Contain Clearance Items 67

70 Metering Equipment Metering Equipment Accessories Fifth Terminals Fifth Terminal Milbank 5T8K2 Fifth Terminal - Milbank 5T8K2 Plug-In fifth terminal meter terminal. Fits round hole. 125/200 Amps. Can be used for 3 O'clock position, 9 O'clock position applications. MIL5T8K2 Fifth Terminal Milbank K3356 Fifth Terminal Assembly, Plug-In (Old Block) Milbank K3356 Fifth Terminal Field mounted fifth Terminal for U3278RL MILK3356 Fifth Terminal Milbank K5T Fifth Terminal for U3278RL Fifth Terminal - Milbank K5T New Style Fifth Terminal Meter Terminal. Fits square hole MILK5T Fifth Terminal New Style Block With Square Hole Interchangeable Unit Hubs Hub Large R Opening - Milbank A811x Metering Equipment MILA8110 MILA8111 MILA8112 Large Interchangeable Unit Hubs - Milbank Large "R" opening (heavy duty). Aluminum Screw Mount Interchangeable Unit Hub. It has standard RL opening. Includes (4) hub screws, threaded NPT 3" - Interchangeable Unit Hub 3R 3-1/2 - Interchangeable Unit Hub 3R 4" - Interchangeable Unit Hub 3R Does Not Contain Clearance Items 68

71 Metering Equipment Metering Equipment Accessories Interchangeable Unit Hubs Hub Small RL Opening - Milbank A751x Small Interchangeable Unit Hubs - Milbank Small "RL" opening (standard). Interchangeable unit hub features aluminum construction for added durability. Includes (4) hub screws, threaded NPT MILA7514 MILA7515 MILA7516 MILA7517 MILA7518 1" - Interchangeable Unit Hub 3R 1-1/4" - Interchangeable Unit Hub 3R 1-1/2" - Interchangeable Unit Hub 3R 2" - Interchangeable Unit Hub 3R 2-1/2" - Interchangeable Unit Hub 3R Hub Adapter Plate - Milbank S8324 Hub Adapter Plate - Milbank S8324 Converts "R" large hub opening to "RL" small hub opening. Painted 16 - gauge steel for added durability. 5"L. MILS8324 Hub Adapter Plate Hub Closing Plates - Milbank A7551-A9064 Milbank Removable Hub Closing Plates MILA7551 Standard for -RL opening / MILA9064 Large for -R opening. Removable hub closing plate features painted aluminum for added durability. It has one locking channel and a hub size of 2-1/2 inches. Plate is used to close meter socket hub opening. plate has a length of inches and is designed for screw mounting, perfect for small RL opening, meter sockets. Plate is ideal for industrial and commercial purpose. Plate is UL listed. MILA7551 MILA9064 Interlock Kit Millbank K5815 Small Removable Hub Closing Plate Large Removable Hub Closing Plate Millbank Interlock Kit - K5815 For generator auxiliary circuit breaker interlock for large frame QN with small frame Q. Can be used for temporary bypass and has reliable current rating of 100 Amps. Kit includes breaker interlock and instruction sheet. Made of steel for added durability. Metering Equipment MILK5815 Interlock Kit Does Not Contain Clearance Items 69

72 Metering Equipment Metering Equipment Accessories Single Conn. Kit - Milbank K1540 Single Connector Kit - Milbank K1540 Aluminum material construction for durability. Connector withstands temperature of 75 deg C. 3 per set. 1 Phase kcmil or (2) 1/0-250 kcmil non-rotating. For use with 3/8"-16 stud type units only. UL listed. Insulated MILK1540 Single Connector Lug Kit, 3 per set, 1-Phase, 600 MCM Max. Multi-Meter 3-Phase Class E-Mon D-Mon E-Mon Class PH Meters Class Phase kwh Demand Meters Direct-read 8-digit LCD display without multiplier displays accumulative kwh and real-time kw load. Demand option displays kw/demand and kw Peak date and time. Revenue Grade Metering Accuracy. 0-2 volt output split-core currrent sensors promote enhanced safety and accurate remote mounting of current sensors up to 2000 feet from meter without power interruption. Includes one set of three split-core current sensors. Can be used on the following configurations: 3- PH, 4-Wire; 3-PH, 3-Wire; 2-PH, 3-Wire. Non-volatile memory. UL/CUL Listed. EMNE JDK EMNE JKI EMNE JDK EMNE JKI 200A, 120/ V, 3 Phase Meter Kit with Demand Option, E JDKIT - 7-1/4"H x 7"W x 3-1/4"D 400A, 120/ V, 3 Phase Meter Kit, E KIT - 7-1/4"H x 7"W x 3-1/4"D 200A, 277/480V, 3 Phase Meter Kit with Demand Option, E JDKIT - 7-1/4"H x 7"W x 3-1/4"D 400A, 277/480V, 3 Phase Meter Kit, E JKIT - 7-1/4"H x 7"W x 3-1/4"D Temporary Power Outlets - Milbank Milbank Metering Equipment - Temporary Power Units Metering Equipment MILU GR 100A Underground Service Power Outlet, Ringless Style, NEMA 3R - 5-1/4"D x 9"W x 25-5/16"H MILU5101XL11GR 1100A Overhead Temporary Power Outlet, Ringless Style, NEMA - 3R8-7/8"W x 5-3/16"D x 25"H Does Not Contain Clearance Items 70

73 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Motor Control Relays & Timers Alternating Relay - Macromatic Alternating Relay, Plug-In - Macromatic ARP Macromatic ARP Series Plug-In Alternating Relays Alternating relays for duplex loads. Can be used with one or two control switches. Compact plug-in design utilizing industrystandard 8 pin octal socket. 10 SPDT output configuration. Optional low profile selector switch to lock in one sequence (MACARP120A6R). 2 LED's marked LOAD A and LOAD B. UL listed with appropriate socket MACARP024A6 MACARP120A6 MACARP120A6R Plug-in Alternating Relay for Duplex Loads, SPDT, 24V AC, 8-Pin Octal Plug-in Alternating Relay for Duplex Loads, SPDT, 120V AC, 8-Pin Octal Plug-in Alternating Relay w/ Selector Switch for Duplex Loads, SPDT, 120V AC, 8-Pin Octal Alternating Relay, Plug-In - Macromatic ATP Macromatic ATP Triplexor Alternating Relays ATP Triplexors are used in three load applications required both the optimization of load usage by equalizing the run time of multiple loads and additional capacity in case of excess load requirements. Works with 3 switch inputs: LEAD, LAG & LAG2. Top-mounted switch allows use as standard Triplexor or as Duplexor until system expansion requires additional third Load. Control Voltage: 120V AC. Plug-in enclosure utilizes industry-standard 8 Pin octal. LED input switch failure indication. UL listed with appropriate socket MACATP120A1R Alternating Relay - SymCom Alternating Relay - SymCom ALT115S Plug-in Alternating Relay w/ Switch for 2 or 3 Loads, 120V AC, 8-Pin Octral Alternating Relay - SymCom ALT115S Used in single high level float applications. Standard SPDT relay VAC, 8-pin plug-in. 0.5 seconds debounce time delay. Alternates between two loads with solid state reliability SYMALT115S Current Sensing - Macromatic Plug-in Alternating Relay, 115V AC, 8-Pin, SPDT,.5 Sec. Debounce Time Delay Current Sensing Relay - Macromatic CM MACCMKP01A62 Macromatic CM Current Sensing Relay Used to detect either an overcurrent or undercurrent condition. Monitors AC single phase currents. External CT can be used to extend ranges. Adjustable pick-up setting with adjustable drop-out setting from 50-95% of pick-up. SPDT 8 pin plug-in. Input voltage: 120V AC. LED indicates output relay status. 10A output contacts. Current Range Monitored: 0.1-1A. UL listed with appropriate socket Current Sensing Relay, AC Plug-in, Adjustable Pick-up Setting, 0.1-1A, 120V AC, 8-Pin Octal Does Not Contain Clearance Items 71 otor Control Relays - Timers - Intrinsical Switches - Voltage Monito

74 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Motor Control Relays & Timers Current Sensing - SymCom Current Sensing Relay - SymCom LSRX AC Current Sensor - SYM LSRX The LSRX is an AC current sensor designed to energize the output contact whenever 4.5 Amps or greater is present. Used commonly as an AC current proof relay to indicate if a motor is operating. It can also be used to interlock fans, compressors, and motors; to indicate equipment status such as feed rates, tool wear, loss of prime on pumps, mixer viscosity, and all types of current sensing conditions. Standard surface mount. Fast-on terminals. LED status indicator. Operating current: 5-200A Continuous. UR, CUR agency approval. Made in USA SYMLSRX AC Current Sensor, 5-200A, Fast-on Terminals General Purpose Relays & Sockets - Cutler-Hammer General Purpose D3PA/PR Series Plug-In Relay - C-H D3PA/PR Cutler-Hammer D3 Series Plug-in Relays C-HD3PRx General purpose compact plug-in relay capable of breaking relatively large load currents. The contact operation can be easily checked by push-to-test button. 8 or 11 pin octal plug-in. C-HD3PA2-A2 C-HD3PA3 C-HD3PR3A D3 Series Relay Socket Base, 8-Pin, Octal, DIN Rail D3 Series Relay Socket Base, 11-Pin, Octal, DIN Rail D3 Series General Purpose Plug-In Relay, 11-Pin, 120VAC, Octal, 3PDT w/ Test Button General Purpose D3RR Series Plug-In Relay - C-H D3RR Eaton Cutler-Hammer D3RR Series The D3 Series of relays provides excellent functionality in a popular octal base design. Rigid pins and guide allow for quick and easy installation with little risk of damage. Compact relay capable of breaking relatively large load currents. Panel and DIN rail mounting. 8- or 11-pin octal plug-in tor Control Relays - Timers - Intrinsical Switches - Voltage Monito C-HD3RR2A D3RR2A General Purpose Relay, 8 Pin, DPDT, 120V AC General Purpose D5PR Series Plug-In Relay - C-H D5PR C-HD5PA2 Cutler-Hammer D5 Series Plug-in Relays C-HD5PRx Industrial rated 300V, 16A relay in two-pole and three-pole configurations. Compact design can be panel or DIN rail mounted. D5 Series Screw Terminal Socket, 11 Pin Screw Socket, DIN / Surface Mount Does Not Contain Clearance Items 72

75 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Motor Control Relays & Timers General Purpose Relays & Sockets - Cutler-Hammer General Purpose D5RR Series Plug-In Relay - C-H D5RR Eaton Cutler-Hammer D5PR-Series Relay, General Purpose, 3PDT Contacts, 120VAC Coil Relay, D5RR General Purpose, 120V AC Coil, Double Throw, 10 Amp, Plug-In, Maximum Switching Voltage 300V C-HD5RR2A C-HD5RR3A Relay, D5 General Purpose, 120V AC Coil, 2-Pole Double Throw, 10 Amp, 8 Blade, Plug-In, Maximum Switching Voltage 300V Relay, D5 General Purpose, 120V AC Coil, 3-Pole Double Throw, 10 Amp, 11 Blade, Plug-In, Maximum Switching Voltage 300V General Purpose D7PA Series Socket - C-H D7PAA Cutler-Hammer D7 Series Socket Base D7PAA 8-Pin relay socket for D7 Series general purpose control relays. Max. voltage rating of 300V. 16A nominal current. DIN rail/panel mount with screw terminals and clamping plates. Module Size B. Protection category (finger safe), EN 60529: IP20 C-HD7PAA D7 Series 8-Pin Relay Socket, 300V, DIN/Panel Mount General Purpose D7PR Series Plug-In Relay - C-H D7PR2T Cutler-Hammer D7 Series Plug-in Relay D7PR2T D7 Series general purpose plain cover plug-in relay. Arc barrier equipped relay with high dielectric strength. Panel and DIN rail mounting. Maximum Switching Voltage: 300V. Contact Configuration: DPDT. Coil Voltage: 24 Vac. Coil Resistance: 180. C-HD7PR2T Level Control Relay - Macromatic D7 Series General Purpose Plug-In Relay, 8-Pin, 24 Vac Coil, DIN/Panel Mount Level Control Relay - Macromatic LCP Series MACLCP2B250F2 Relay Level Control - LCP Series Plugin Controls Level of Conductive Liquids in Pump Up (Fill) or Pump Down (Drain) Applications. Single or Dual Probe. Factory- Fixed Time Delay of 1-60 Seconds Prevents Rapid Cycling ( Single Probe only). Uses industry-standard 8 pin octal socket LCP Series Relay Level Control, Single or Dual Probe, 8 Pin Octal Socket, 120VAC Does Not Contain Clearance Items 73 otor Control Relays - Timers - Intrinsical Switches - Voltage Monito

76 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Motor Control Relays & Timers Level Control Relay - SSAC Level Control Relay - SSAC LLC4 Series SSAC LLC4 Series Liquid Level Controls The LLC4 combines resistance sensing circuitry with solid-state timing to provide single probe level control for conductive liquid. Adjustable sense resistance (1-250k). Mounting: Plug-in socket. Termination: Octal 8-Pin Plug-in. Sensing Voltage: Plused DC at probe terminals. Operation, Drain (pump-down mode): When the liquid level rises and touches the probe, the time delay begins. This time delay prevents rapid cycling of the output relay and its load. At the end of the time delay, the output relay and LED energize and remain energized until the liquid level falls below the probe level. The output relay and LED de-energize and remain de-energized until the liquid rises and touches the probe SSALLC44A5A Load Sensor - SymCom Load Sensor - SymCom LSR-115 Liquid Level Control, Drain Operation, 120VAC, 5 Sec. Fixed Time Delay, Adj. Sense Resistance Load Sensor - SymCom LSR-115 Load Sensors use current levels to determine feed rates, tool wear, loss of prime on pumps, mixer viscosity, and all types of over and under load conditions. Combines a current transformer (CT) with Form C (SPDT) relay contacts to switch alarm circuits contactors, or any resistive or inductive load. One simple screwdriver adjustment will calibrate the sensor for all single phase or three phase applications up to 100 Hp. Uses 115 VAC control voltage. Screw terminal connections. Standard surface mount. Adjustable potentiometer. Made in USA. CSA and CSA-NRTL/C. SYMLSR115 Load Sensor, 115 VAC Control Voltage, 2-135A Range Overload Relay - SymCom Overload Relay 1-Phase - SymCom 77C tor Control Relays - Timers - Intrinsical Switches - Voltage Monito SYM77C Overload Relay Single-Phase - SYM 77C The 77C is a fully-programmable electronic overload relay designed to monitor single-phase systems. It can be used as a stand-alone product or the communication port can be used to form a network to monitor the motors from a PC or other control system. Applications included conveyor systems, HVAC equipment, pumps, saws, grinder, and other single-phase electric motors. Protects from overload, underload, jams, lowvoltage, high voltage and rapid cycling. Automatic and manual reset, tamper guard, RS-485 communication port, surface and DIN rail mountable, and last fault memory. Motor Full Load Amp Range: 2-25A, 1-phase (loops required); 26-90A, 1-phase (direct); A, 1-phase, (external CTs). UL and cul listed. Made in USA Single-Phase Overload Relay, V, 50/60Hz Overload Relay 3-Phase - SymCom 777 MotorSaver Overload Relay - SYM 777 The 777 is a fully-programmable electronic 3-phase overload relay. An alphanumeric LED display provides programming and diagnostic information. Sixteen parameters can be programmed in an easy four step process. UL and cul listed. Features automatic or manual reset. Tamper guard. RS485 communications port. Surface mount or DIN rail mount. Last fault memory. Made in USA SYM Three Phase Overload Relay, 8-800A, V SYM777LRP2 Three Phase Overload Relay, 1-9A, V SYM777P2 Three Phase Overload Relay, Motor Saver Plus, 8-800A, V Does Not Contain Clearance Items 74

77 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Motor Control Relays & Timers Phase Relay - Macromatic Phase Monitor Relay - Macromatic PMPU The Macromatic Phase Monitor Relay provides protection against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage. The universal voltage range of V provides the flexibility to cover a vareity of applications with one unit. Automatic and manual reset in same unit. Multi-color LED indicates normal condition and provides specific fault indication to to simplify troubleshooting. Output contacts: SPDT: AC/30V DC, 240V AC. Plug-in case uses an 8-pin octal socket. Requires a 600V-rated socket when used on system voltages above 300V. MACPMPU Phase Monitor Relay, V, 50/60Hz, Plug-in 8-Pin Socket Base, 10A SPDT Output Contacts Phase Monitor Relay - Macromatic PMPU-FA8 Phase Monitor Relay - Macromatic PMPU-FA8 Protects against phase loss, phase reversal, phase unbalance, undervoltage & overvoltage. Voltage range of VAC. Automatic reset. Bi-Color status LED indicates normal condition and provides specific fault indication to simplify troubleshooting. Output: 10A SPDT. Compact plug-in case uses an 8-pin octal socket MACPMPUFA8 Phase Monitor Relay, V, 50/60Hz, Plug-in, 8-Pin 10A SPDT Output Phase Monitor Relay - Macromatic PMPU-FA8X Phase Monitor Relay - Macromatic PMPU-FA8X Protects against phase loss, phase reversal, phase unbalance, undervoltage & overvoltage. Univeral voltage range of VAC provides the flexibility to cover a variety of applications with one unit. Automatic reset. Multi-color LED indicates normal condition and provides specific fault indication to simplify troubleshooting. Output: 10A SPDT/SPNO. Compact plugin case uses an 8-pin octal socket. Requires a 600V-rated socket when used on system voltages above 300V MACPMPUFA8X Phase Monitor Relay, V, 50/60Hz, Plug-in, 8-Pin 10A SPDT/SPNO Output Pump Seal Failure Relay - Macromatic Pump Seal Failure Relay - Macromatic Series SFP MACSFP120A100 MACSFP120A250 MACSFP120C100 Macromatic SFP Pump Seal Failure Relay SFP Series Plug in Pump Seal Failure Relays monitor submersible pump seals for leakage. A resistive-measuring probe is installed in the pump seal cavity, when resistance drops below the user-adjustable sensitivity set-point of the relay, the output relay energizes and the red LED turns ON. Two adjustable sensitivity ranges. Probe is pulsed with a DC voltage to prevent electroplating. Input Voltage: 120V AC. Low profile adjustment knob. UL listed with appropriate socket. Plug-in Pump Seal Failure Relay, Single Channel, 8-Pin SPDT, 120V AC, Sensitivity Range 4.7K to 100K Ohms Plug-in Pump Seal Failure Relay, Single Channel, 8-Pin SPDT, 120V AC, Sensitivity Range 1K to 250K Ohms Plug-in Pump Seal Failure Relay, Dual Channel, 8-Pin (2) SPNO, 120V AC, Sensitivity Range 4.7K to 100K Ohms Does Not Contain Clearance Items 75 otor Control Relays - Timers - Intrinsical Switches - Voltage Monito

78 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Motor Control Relays & Timers Time Delay Relay - Cutler-Hammer Time Delay Relay - Signal Triggered - C-H TR Series Cutler-Hammer TR Series Timing Relays C-HTRFPx TR plug-in timing relays, signal triggered. 20 time ranges and 10 timing functions. Time delays from 0.1 sec to 600 hrs. Space-saving, compact package. 2 Form C DPDT delayed output contacts. 10A contact rating C-HTRFP240AC C-HTRNP240AC Time Delay Relay - Macromatic Signal Triggered TR Plug-In Timing Relay, VAC, 11-Pin Octal Power Triggered TR Plug-In Timing Relay VAC, 8-Pin Octal Time Delay Relay - Current Sensing - Macromatic CAH Macromatic CAH - CAH20A2AC Overcurrent Sensing After input voltage is applied & the sensing delay on power-up (ts) is completed, the unit will begin sensing for a fault condition. A fault will occur when the monitored AC current (I) goes above the Fault Trip Current setting & remains above the Reset level for a period longer than the adjustable time delay period (t). The LED will turn ON immediately and the relay will energize after the time delay on pick-up (t) is completed. The relay will de-energize & the LED will turn OFF when the monitored AC current goes below the Reset level. Undercurrent Sensing After input voltage is applied & the sensing delay on power-up (ts) is completed, the unit will begin sensing for a fault condition. A fault will occur when the monitored AC current (I) goes below the Fault Trip Current setting & remains below the Reset level for a period longer than the adjustable time delay period (t). The LED will turn ON immediately and the relay will energize after the time delay on pick-up (t) is completed. The relay will de-energize & the LED will turn OFF when the monitored AC current goes above the Reset level. Application information: Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. Load (Burden): 2 VA for all voltages. Indicator LEDs: Red ON Steady when Fault occurs Current Sensing: Range: 2-20A. Type: Toroidal, through hole wiring. Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%. Maximum Allowable Current: Steady-50A Turns; 300A Inrush for 10 Seconds. Trip Point Hysteresis: -5% Overcurrent sensing +5% Undercurrent sensing. tor Control Relays - Timers - Intrinsical Switches - Voltage Monito MACCAH20A2AC Response Times: Trip Delay (Relay ON): See Table Above. Sensing Delay on Start-up: See Table Above. Time Delay on Reset (Relay OFF): 100ms. Reset Time: 400ms. Output Contacts: VAC, General Purpose; 8 28VDC, Resistive; 120/240VAC; B300 Life: Mechanical: 10,000,000 operations; Full Load: 100,000 operations. Temperature: (Storage) -40 to 85 C (-40 to 185 F); (Operating) -28o to 65o C (-18o to 149o F) Time Delay & Current Sensing Relay, Sec, 120V AC/DC, 20A Time Delay Relay - Inline - Macromatic THL-1024U MACTHL1024U32 THL Series Time Delay Relays Onboard adjustable time delay. Encapsulated 2" x 2" enclosure with single screw mounting. Microprocessor-based design for reliable performance & maximum flexibility. Two-terminal series-connection with the load. Normally Open output rated 1A continuous/10a inrush is perfect for high duty cycle/long life applications. Universal input voltage of VAC & 12-48VDC Inline Time Delay Relay, Onboard Adj., Timing Range Min., VAC VDC Does Not Contain Clearance Items 76

79 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Motor Control Relays & Timers Time Delay Relay - Macromatic Time Delay Relay - Macromatic TD Macromatic Time Delay Relay - Macromatic TD Sixteen user-selectable modes in one unit. Programming is accomplished through the use of two 10-position DIP-Switches for accurate digital set of time delay and selection of function. 0.1 sec. - 1,023 hours programmable time delay (31 hrs. max. dual mode). Input Voltage: 120V AC/DC. Output: 10A DPDT. Uses industry-standard 11-pin octal socket MACTD88122 Time Delay Relay w/ Dip Switch, 16-Function, 0.1 Sec. - 1,023 Hr., 120V AC/DC, 11 Pin Octal Socket Time Delay Relay - Non-Prog. - Macromatic TR-5 TR-5 Non-Programmable Plug-in Time Delay Relays Each unit has a single timing range. Plug-in case utilizing industry-standary 8 or 11 pin octal sockets 10A DPDT output contacts MACTR MACTR MACTR On Delay Relay, Non-Programmable, Plug-in, 120V AC/DC, Sec. Time Delay Range, 8 Pin Octal Interval On Relay, Non-Programmable, Plug-in, 120V AC/DC, Sec. Time Delay Range, 8 Pin Octal Off Delay Relay, Non-Programmable, Plug-in, 120VAC/DC, Sec. Time Delay Range, 11 Pin Octal Time Delay Relay - Programmable Macromatic TR6022x Time Ranger On Delay Relay - Macromatic TR6022x TR-6 Time Ranger Programmable plug-in time delay relays are flexible and reliable. Select one of the 16 built-in time ranges by setting the rotary switch per a chart on the unit and adjust within that range using the knob on top. Single Time Unit, 0.1 Sec. - 2 hr. Timing Range. Function: On Delay. 10 DPDT output contacts MACTR60222 MACTR60226 On Delay Relay, Programmable, Plug-in, Input Voltage: 120V AC/DC, Multi-Range Single Time Unit 0.1 Sec. - 2 Hr. On Delay Relay, Programmable, Plug-in, Input Voltage: 12V AC/DC, Multi-Range Single Time Unit 0.1 Sec. - 2 Hr. Time Delay Relay - Single Shot Prog. - Macromatic TR-6 MACTR6152U Time Ranger Single Shot Relay - Macromatic TR-6 TR-6 Time Ranger Programmable plug-in time delay relays are flexible and reliable. Select one of the 16 built-in time ranges by setting the rotary switch per a chart on the unit and adjust within that range using the knob on top. Function: Single Shot, Control Switch Trigger. Single Time Units 0.1 second - 2 hour. 10A DPDT output contacts. Single Shot Relay, Programmable, Plug-in, Input Voltage: V AC/DC, Multi-Range Single Time Unit 0.1 Sec. - 2 Hr. Does Not Contain Clearance Items 77 otor Control Relays - Timers - Intrinsical Switches - Voltage Monito

80 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Motor Control Relays & Timers Time Delay Relay - Macromatic Time Delay Relay - True Off - Macromatic TR6062x Time Ranger True Off Delay Relay - Macromatic TR6062x Time Ranger programmable plug-in True Off Delay provides Off Delay function without requiring input voltage during Off time delay. Duplicates operation of pneumatic Off Delay timers. Unit has 8 timing ranges built-in, covering 0.05 seconds to 30 minutes. Selecting a range is easy using a rotary switch. Uses industry-standard 8 pin octal socket. 10A DPDT output contacts MACTR60622 MACTR60628 Time Delay Relay - SSAC True Off Delay Relay, Programmable, Plug-in, Input Voltage: 120V AC/DC, 0.05 Sec Min. Timing Range True Off Delay Relay, Programmable, Plug-in, Input Voltage: 24V AC/DC, 0.05 Sec Min. Timing Range Time Delay Relay Delay-On-Break - SSAC TSB434 SSAC TSB434 Timer - Delay-On-Break The TSB Series is a totally solid-state, delay-on-break timing module. Input Voltage: 120VAC. Onboard adjustment. Time Delay: Seconds. The repeat accuracy is ±2%. The TSB s 1A steady state, 10A rated, solid-state output is perfect for direct control of solenoids, contactors, relays, lamps, buzzers, and small heaters. The TSB can be surface mounted with a single screw, or snapped on a 35 mm DIN rail using the P adaptor SSATSB434 Timer, Delay-On-Break, 120VAC, Onboard Adjustment, Time Delay Seconds Voltage Relay - Macromatic Voltage Monitor Relay - Macromatic VAKP240A tor Control Relays - Timers - Intrinsical Switches - Voltage Monito MACVAKP240A Macromatic Voltage Monitor Relay VAKP240A Adjust the over voltage setting (Umax) between the full range as shown on the product nameplate. Adjust the under voltage setting (Umin) between 75% and 95% of the over voltage setting. The relay energizes (and the LED is Red) when the monitored voltage is between the over and under voltage settings. The relay de-energizes (and the LED is Green) when the monitored voltage falls outside the over or under voltage settings for a period longer than the drop-out time delay (t), which is adjustable from seconds. The relay re-energizes when the monitored voltage returns to a value between the over and under voltage settings for a period longer than the pick-up time delay, which is fi xed at 0.5 seconds. Relay Socket Bases Socket Relay Bases - Macromatic Over/Under Voltage, Adjustable Time Delay of Seconds on Drop-out, 240V Output: 10A SPDT Macromatic Relay Bases - Macromatic 701 MAC70169D MAC70170D Macromatic Octal Socket Bases Relay bases, surface or DIN rail-mounted. 1 or 2 #12-22 AWG wire. Pressure clamp terminations 8 Pin Octal Socket Base, Surface or DIN Rail-Mounted, 600V 11 Pin Octal Socket Base, Surface or DIN Rail-Mounted, 300V Does Not Contain Clearance Items 78

81 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Relay Socket Bases Socket Relay Bases - Octal Socket Octal Base - CUS RB08PC & RB11PC Octal Relay Socket - CUS Relay Sockets, 8 Octal and 11 Pin Octal. Wire up to one No. 12 AWG. Lugs recommended on wire larger than No. 16 AWG. Rating 10 Amps at 600 Volts. Terminals #6-32 Screws, 5/16" Long, Steel, Nickel Plated. UL Recognized, CSA Certified CUSRB08PC CUSRB11PC Socket Base 8 Pin Octal Socket Base 11 Pin Octal Socket Octal Base - TMK 51X120 8-Pin Octal Socket - Time Mark 51X Amps at 600VAC Rating. Surface or DIN-rail mount. Suitable for use with Time Mark relays up to 480VAC. The thermoplastic body can withstand tempratures up to 300 degree F continuously without melting or electrical breakdown. Terminals are #6-32 screws, and are suitable for use with wire sizes up to two #12 AWG. The one piece molded body does not require a separate insulator strip. UL & CSA Certified TMK51X120 Socket Base 8 Pin Octal Safety Switches - Intrinsically Safe SymCom Dual-Channel Switch - SYM ISS102AADCS Intrinsically Safe Switch - SymCom ISS-102AA-DCS A dual-channel switch with two form-a output relays. The input resistance threshold is fixed at 100k Ohms fixed. Each output contact closes upon closure of its associated input switch. Resistance probes or switches can be used on the inputs. Debounce time delay: 0.5 second. Green LEDs illuminate when the associated output relay is energized. 120V AC nominal supply voltage. 50/60 Hz frequency AWG wire size.dimensions: 3.5" L x 2.1"w x 2.5"D. Mounting: 35 mm or DIN rail or surface mount. UL listed SYMISS102AADCS Five-Channel Pumpsaver - SYM ISS105 SYMISS105 Intrinsically-Safe Dual-Channel Switch, with Two Form-A Output Relays, 120V SymCom PumpSaver ISS-105 Five-channel intrinsically safe relay and pump controller. Typical applications: duplex pump down with high and low alarms. Can indicate low, high and out-of-sequence alarms. Can be set up to do non-alternating control, alternating control and alternating control with one non-alternating pump. Compact design. Pump up or pump down control. Finger safe terminals. DIN rail or surface mountable. LED state indicator. Isolated output relay for PLC or control voltage 5-Channel Intrisically-Safe Switch/Pump Control, 120V Does Not Contain Clearance Items 79 otor Control Relays - Timers - Intrinsical Switches - Voltage Monito

82 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Safety Switches - Intrinsically Safe SymCom Five-Channel PumpSaver - SYM ISS105ISO 5-Channel Intrinsically Safe Switch - SYM ISS-105-ISO Suitable for applications with switch inputs in hazardous locations. The five channels operate independently of each other and each input and output relay has an LED that illuninates when the corresponding input and output relay activates.logic can be inverted. Supply voltage: 120VAC. Debounce time: 2 seconds. Mounting: DIN rail or surface mount. UL 913 listed. Made in USA SYMISS105ISO Multi-Function - SYM ISS102ACIMC Intrinsically Safe PumpSaver Switch, 5-Channel, 120V Intrinsically-Safe Multi-Function Controller - SYM ISS-102ACI-MC User-configurable as a single or dual-channel switch, or pump-up/pump-down controller. The intrinsically-safe inputs are compatible with normally open (N.O.) or normally closed (N.C.) switches, as well as resistive probes. Input logic: direct or inverted. Debounce time delay: 0.5 or 2 sec. Supply Voltage: 120VAC nominal. Terminal wire size: AWG. Mounting: 35mm DIN rail or surface mount SYMISS102ACIMC One-Channel Switch - SYM ISS-100 Intrinsically Safe Multi Function Switch / Controller 1-Channel Intrinsically Safe Switch - SYM ISS-100 The ISS-100 is UL 913 listed as an associated apparatus for interfacing between hazardous and non-hazardous areas. Must be installed in an non-hazardous area. Follow SymCom's Control Drawing 100 for proper installation. Finger safe terminals. DIN rail or surface mountable. LED state indicator. Isolated output relay for PLC or control voltage. Supply voltage: VAC. Wire range: 12 to 20 AWG. Made in USA tor Control Relays - Timers - Intrinsical Switches - Voltage Monito SYMISS100 Intrinsically Safe Switch, 1-Channel, Vac Square D - Controls - Relays - Timers Square D 8501 General Purpose Relays Square D - Type C Panel Mount 8501CO QO8501CO16V14 QO8501CO16V20 QO8501CO7V20 Square D Type C Power Relays Class 8501 Type C relays are ideally suited for controlling small single phase motors and other light loads such as electric heaters, pilot lights or audible signals. 30 Ampere contact rating. AC operated coil, open type. 600V maximum contact voltage. Horsepower Rated. Visible contacts. UL/CSA Listed. Type C Power Relay, DPDT Contact Arrangement, 2 N.O. 2 N.C.Fixed Contacts, 24V AC, 1-1/2 1-Phase Max HP Type C Power Relay, DPDT Contact Arrangement, 2 N.O. 2 N.C., 120V AC, 1-1/2 1-Phase Max HP Type C Power Relay, DPST Contact Arrangement, 2 N.O. Fixed Contacts, 120V AC, 1-1/2 1-Phase Max HP Does Not Contain Clearance Items 80

83 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Square D - Controls - Relays - Timers Square D 8501 General Purpose Relays Square D - Type KP Tubular Terminal 8501KP Square D Type KP Plug-in Relay 8501KP relays are designed for multipole switching applications at 240 volts or lower. These relays have industry standard wiring and pin arrangements which allows for their use as replacements for many similar relays without wiring or hardware modifications. Type of Pins: Tubular Terminals. Mounting type: Socket. Horsepower Rated. RoHS Compliant. QO8501KPR12V14 QO8501KPR12V20 Type KP Plug-In Relay, Tubular Terminal, DPDT Contact Arrangement, Coil Voltage 24V AC, 10A, 8 Pin Octal Base Type KP Plug-In Relay, Tubular Terminal, DPDT Contact Arrangement, Coil Voltage: 120V AC, 10A, 8 Pin Octal Base Square D - Type KUR Spade Terminals 8501KUR Square D Type 8501KUR13P14V Relay 10A relay, blade. 3PDT switch function. 120VAC coil volts. 11 Pins. Rated power in hp: 1 hp 277V, 0.33 hp 120V. Maximum switching voltage: 30 V DC, 300 V AC. Standard clear cover with LED. QO8501KUR13P14V Type KUR Relay Blade, 3PDT, 10A, 120 Vac Coil Voltage, Standard Coil w/ LED Square D 8501NR - Series Relay Sockets Square D - Relay Socket NR Square D - Socket Class 8501 Type NR51 Snapmount socket is designed for use with plug-in 8501 Type KP12 and KPD12 relays. Pressure clamps will accept 1 or 2 #12-22 wires. The recommended tightening torque is 7-8 lb-in. Socket Rating: 10A@600V, 15A@300V UL - 10A@300V CSA. Number of Tubular Pins: 8. Socket Type: Single Tier. Mounting: Panel or DIN Rail. QO8501NR51 QO8501NR82 QO8501NR82B Type N Relay Socket, 10A@600V, 15A@300V, Socket Rating, 8-Pin Tubular, 1-Tier, Screw Terminal Type N Socket, 15A@300V Socket Rating, 11-Pin Spade, Double Tier, Screw Terminal Type N Socket, 15A@300V Socket Rating, 11-Pin Spade, Double Tier, Screw Terminal - BULK Square D 9050 JCK Electronic Timing Relay Square D - Timing Relay JCK QO9050JCK12V20 QO9050JCK14V20 Square D JCK12V20 Timer Variable electronic plug-in timing relay. Knob Adjustable Timing Range: 0.3 to 30 seconds. Contact Break: 3A@120VAC, 1.5A@240VAC. Horsepower Rating: 1/3HP@120VAC - 1/2HP@240VAC. Coil Voltage 120/110 AC/DC. Contact Arrangement: DPDT. Contact Configuration: 2 N.O./ 2 N.C. Timing Mode: ON Delay. Number of Tubular Pins: 8 Pin. Mounting Type: Socket. Contact Make: 30A@120VAC, 15A@240VAC. Ampere Rating: 10A. Type JCK Plug-in Variable Time Delay Relay, 120V, Seconds Knob Adjustable Timing Range Type JCK Plug-in Variable Time Delay Relay, 120V, Seconds Knob Adjustable Timing Range Does Not Contain Clearance Items 81 otor Control Relays - Timers - Intrinsical Switches - Voltage Monito

84 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Square D - Controls - Relays - Timers Square D NEMA Relay 8501XO - Series Square D - NEMA Relay XO Square D NEMA Relay - Square D 8501 Type X relays combine a rugged, heavy-duty design with modular construction for greater design flexibility Square D Class 8501 Type X relays combine a rugged, heavy-duty design with modular construction for greater flexibility. They are ideal for those applications where long life, high reliability and ease of maintenance are important. The Type X family offers a complete line of relays and accessories for all control applications. Key features of the Square D 8501 Type X Relays. Specified In Major Automotive Plants. Modular Design Provides Greater Versatility and Reduction In Stock. XUDO Version Ideal for Power Plant Applications. Replaceable, Convertible Contacts. Extremely Reliable Contacts. 600 Volt 10 Ampere Rating (NEMA Type A600). Plug-In Color-Coded Contact Cartridges. Mechanical Tie Between Contact Cartridges. 1 and 3 Minute Timing Relays. 8 Pole Latching Relays. DC Operated Relays. Applications: Distribution, Construction, Bottling, Car Washes, Oil & Gas, Crane & Hoist, Automotive, Food & Beverage, Industrial Markets QO8501XO40V02 QO8501XO80V02 Voltage Monitors Voltage Monitor - SymCom Type X Control Relay, 4 N.O. Contacts, 120V Coil Voltage Type X Control Relay, 8 N.O. Contacts, 120V Coil Voltage 1-Phase PumpSaver Plus Monitor- SYM 233-P One-Phase PumpSaver Plus - SymCom 233P Designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid cycle and overvoltage and undervoltage condtions. Protects 230 volt, 2 or 3 wire, 1/3 to 3 hp pumps. A calibration adjustment allows the 233-P to be calibrated to your specific pumping applications, thereby reducing the possibilty of false or nuisance tripping. Features a user selectable "restart delay" (dry-well recovery) timer. UL Listed. Made in USA SYM233P Single-Phase PumpSaver Plus Pump Monitor, 230VAC 1-Phase Voltage Monitor - SYM SP tor Control Relays - Timers - Intrinsical Switches - Voltage Monito Single-Phase Voltage Monitor - SYM SP 8-pin octal base plug-in voltage monitor designed to protect single-phase motors regardless of size. Microcontroller based for better accuracy. It can be used on VAC motors to prevent damage caused by low voltage. Diagnostic LED. UL508 Listed. CE Marked. DIN rail or surface mount. Made in USA SYM201200SP Single-Phase Plug-in Voltage Monitor, V 3-Phase Voltage Monitor - SYM 201A SYM201A Three-Phase Plug-in Voltage Monitor - SymCom 201A The 201A is an auto ranging 8-pin, plug-in voltage monitor designed to protect VAC, 3-phase motors regardless of size. It is used to prevent damage caused by single-phasing, low voltage, phase reversal and voltage unbalance conditions. Diagnostic LED. UL listed, CE compliant. Made in USA Three Phase Plug-in Voltage Monitor, VAC1.75"H x 2.375"W x 4.125"D (w/socket) Does Not Contain Clearance Items 82

85 Motor Control Relays - Timers - Intrinsical Switches - Voltage Monitors Voltage Monitors Voltage Monitor - SymCom 3-Phase Voltage Monitor - SYM 201A-AU Three-Phase Plug-in Voltage Monitor - SymCom 201A-AU Microcontroller based for better accuracy. Universal range from VAC, 50/60Hz provides versatility to handle global applications. Protects 3-phase motors from loss of any phase, low voltage, high voltage, voltage unbalance, phase reversal and rapid cycling. UL and cul listed. Bi-color LED indicates trip status and provides simple troubleshooting. Standard manual, sec. variable restart delay. DIN rail mounted octal base. Made in USA SYM201AAU Three Phase Universal Voltage Monitor, VAC 3-Phase Voltage Monitor - SYM Three-Phase Voltage Monitor - SYM This 3-phase voltage monitor is perfect for heavy-duty applications such as rural pump panels, commercial and rural HVAC equipment, and oil rigs. Monitors 380 to 480V imput voltages. Engineered protection. Microcontroller based. Protects 3-Phase motors from: loss of any phase (single-phasing), low voltage, voltage unbalance, phase reversal, and optional high voltage. Bicolor LED indicator light is green in normal conditions and red during trip conditions. Standard surface mount. UL and cul listed. Made in USA SYM SYM Phase Voltage Monitor - SYM 460 Three Phase Voltage Monitor, VAC input voltages Three Phase Voltage Monitor, VAC input w/ Two DPDT 15A Relays Three-Phase Voltage Monitor - SYM 460 The Model 460 is designed to protect 3-phase motors from damaging power conditions. Universal range from Vac, 50/60Hz provides the versatility needed to handle global applications. Four adjustment pots provide versatility for a variety of appliations. Microcontroller-based circuitry provides better accuracy. Standard surface or DIN rail mountable. Standard sec. variable restart delay. Finger-safe terminals. UL and cul listed, CE compliant. Made in USA SYM460 Three Phase Voltage Monitor, VAC, 50/60Hz Motor Controls - Contactors - Switches - Disconnects AC Disconnects and Spa Panels AC Disconnects & Spa Panels - Cutler-Hammer Non-Fused AC Disconnects - C-H ACD222URNM Air Conditioning Disconnect Non-Fused Pullouts. 60A Main ampere rating. Horsepower rated 10 hp max. at 240 Vac. Non-metallic, polycarbonate enclosure. Easy to remove front cover. NEMA 3R C-HACD222URNM 60A - A/C Disconnect, Non-Fused Pullout, Non-Metallic, NEMA 3R, 10 HP, 1-PH, 120/240 Does Not Contain Clearance Items 83 otor Control Relays - Timers - Intrinsical Switches - Voltage Monito

86 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects AC Disconnects and Spa Panels AC Disconnects & Spa Panels - Cutler-Hammer Non-Fused AC Disconnects - C-H DPU222R C-HDPU222R C-HDPU222RGF20S 60A Air Conditioner Disconnects Located between the loadcenter and air conditioner, an air conditoner disconnect provides a visible disconnection means when performing maintenance. Non-Fused pullouts. 240V, 2-Pole, 3-Wire. NEMA 3R 60A - A/C Disconnect, Non-Fused Pullout, Galvanized Steel, NEMA 3R, 10 HP, 240V, 2-Pole 60A - A/C Disconnect w/ 20A Ground Fault Receptacle, Non-Fused Pullout, NEMA 3R, 10 HP, 240V, 2-Pole Spa Box Panelboard - Cutler-Hammer - CH50SPAST Electrical - Distribution & Controls Spa Box Panelboard - C-H CH50SPAST Eaton's CH Spa Panels provide premium protection with features such as solid copper bus and three-quarter-inch circuit breaker. They meet all NEC requirements, offer reliable protection for spa pumps, pools, and hot tubs, and provide a ground fault circuit interruption device and a disconnect switch in a single simple device. Fully assembled and prewired for fast, efficient installation. Tough powder-coat painted galvanized steel enclosure stands up to all types of weather conditions. Factory-installed 2-pole 50 amp ground fault self-test circuit interrupter (GFCI). Padlockable door prevents tampering and eliminates unauthorized access. Interior dead front cover provides protection against contact with energized parts. Door swings open and stays open for easy interior access. Comes with a 4-circuit interior that allows for 2 extra 120V circuits for convenience receptacles or lighting. Solid copper bus bars offer the ultimate in reliability and energy efficiency. Only Type CH breakers can be used. C-HCH50SPAST Fusible AC Disconnects - Midwest Fusible AC Disconnects Midwest P0-F 50A - Spa Panel, GFCI, Non-Fused, Self Test, 4 Circuit CH Loadcenter, NEMA 3R, 10 HP, 240V, 2-Pole, 1-PH Non Metallic Fusible AC Disconnects 240 Volts A.C. 10,000 AIC. 1 Phase. Thermoplastic enclosure. 6" x 8" cabinet size. Door has padlock provisions. Pullers are removable or reinstallable in the OFF position for user safety during equipment maintenance. The P065F UL listing includes the ability to field replace the 60A puller with a 30A puller (FR352) for installation flexibility. Listed for use as service entrance. MDWP035F MDWP065F Fusible AC Disconnects Midwest U0-F 30A, 240V, HP Rating 3, Fusible AC Disconnect, Non Metallic 60A, 240V, HP Rating 10, Fusible AC Disconnect, Non Metallic Metallic Fusible AC Disconnects 240 Volts A.C. 10,000 AIC. 1 Phase. Metallic surface mount enclosure. Fused pull-out circuit protection. Pullers are removable or reinstallable in the OFF position for user safety during equipment mainetnance. Listed for use as service entrance. MDWU035F1 MDWU065F1 30A, 240V, 3 HP Rating, Fusible AC Disconnect Pullout, Metallic, 5x7 Cabinet (#U035F2) 60A, 240V, 10 HP Rating, Fusible AC Disconnect Pullout, Metallic, 5x9 Cabinet Does Not Contain Clearance Items 84

87 Motor Controls - Contactors - Switches - Disconnects AC Disconnects and Spa Panels HVAC Disconnects Fused / Non-Fused Mars AC Disconnects Fused / Non-Fused Mars Fused and Non-Fused Single Phase Disconnect MARS offers both fusible and non-fusible single phase air conditioner disconnects. These units provide a disconnecting means which should be located within sight from and readily accessible from the air conditioning or refrigerating equipment. UL listed.. Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects MRS A AC w/gfci Recepticle Non-Fused Disconnect "H x 6"W x 3"D MRS83317 MRS83335 MRS A AC Fused Disconnect - 9"H x 5"W x 2.75"D 60A AC Non-Fused Disconnect "H x 5"W x 2.13"D 30A AC Fused Disconnect "H x 5"W x 2.13"D Non-Fused AC Disconnects - Midwest Non-Fused AC Disconnect Midwest P065P Non-Fused Pull-Out AC Disconnect - MDWP065P 240 Volts A.C. 10,000 AIC. 1 Phase. Plastic enclosure. Surface mount. 6" x 8" cabinet size. Non-fusible disconnect pullers are removable or reinstallable in the OFF position for user safety during equipment maintenance. MDWP065P 60A, 240V, HP Rating 10, Non-Fused Pull-Out, AC Disconnect, Non Metallic Non-Fused AC Disconnect Midwest U065P Non-Fusible AC Disconnect - MDWU065P 240 Volts A.C. 10,000 AIC. 1 Phase. Circuit Protection: Non-Fused Pull-Out. Metallic Enclosure. Wire range: D. Cabinet Size: 5" x 7". Metallic, non-fusible disconnect pullers are removable or reinstallable in the OFF position for user safety during equipment maintenance. MDWU065P 60A, 240V, 10 HP Rating, Non-Fused Pullout, AC Disconnect, Metallic Does Not Contain Clearance Items 85

88 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects AC Disconnects and Spa Panels Non-Fused AC Disconnects - Milbank Non-Fused AC Disconnect - Milbank U382220GWR MILU382220GWR Milbank AC Disconnect & GFCI - U GWR Combination AC Disconnect and 20 Amp. GFCI Receptacle. Meets NEC # Requirements. NEC Weatherproof Ground-fault interruptor protection for personnel. 60 Amp. non-fused AC disconnect. Duplex 20 Amp GFCI receptacle with reset/test button. Type 3R enclosure with in-use cover. 1" Concentric knockouts. Max. H.P. 10. AC disconnect wire range: CU #14-#2 AWG, AL #12-#2 AWG. Ground connector wire range: CU/AL #14-#4 AWG. Dimensions: 4.8"D x 5.25"W x 7.4"H. Spa Pack Homeline - Square D 60A, 240V, Non-fusible AC Disconnect and 20A GFCI Receptacle Square D - Enclosed GFCI Spa Pack - QO HOME250SPA Electrical - Distribution & Controls Homeline Hot Tub/Pool/Spa Pack - QOHOME250SPA 50A Homeline 2-Pole QUIK-GARD ground fault circuit breaker (HOM250GFI) installed in a 50A outdoor load center (HOM2-4L50R). Protects 120V and 240V loads against ground and overcurrent faults. NEMA 3R, rainproof, steel enclosure. Top-hinged door can be padlocked. 10,000 AIR. Dimensions: 9.5"H x 5.4"W x 4.4"D. QOHOME250SPA Spa Panels - Midwest Spa Panels Midwest UG412RMW NEMA 3R Enclosed GFCI Circuit Breaker, 50A rating, 2-Pole, HOM250GFI Breaker Included Midwest UG412RMW Spa Panels GFI disconnects provide a convenient, low cost means to satisfy NEC requirements for spas, hot tubs, water heaters and swimming pools. The NEMA 3R design insures a safe, weather tight installation for residential, light commercial, and even some industrial applications. Metalic enclosure, surface mounting, hub provision, 1-phase. Installed Breaker: 2-Pole GFI. Volts: 120/240V. AIC: 10,000. Load Center: 125A rated; w/ 2 or 4 extra breaker spaces. Cabinet Size: 7-1/2" x 10". Enclosure Rating: 125A. Wire Range: #6-2/0 (Cu/Al). UL/CUL listed MDWUG412RMW250 MDWUG412RMW260 Cooper - Motor Switches Cooper Wiring Devices - Switches Motor Control Switch CWDAH7810UD 50A, 120/240V, Spa Panel, UL GFI Breaker Panel, +2 Circuit Bkr. Spaces 60A, 120/240V, Spa Panel, UL GFI Breaker Panel, +2 Circuit Bkr. Spaces Motor Control Switch Unit - CWDAH7810UD Industrial Specification Grade manual switch, built tough for dependable motor control. 30 Amps 600V/AC, 3-Pole, 3- Phase. Two-position, maintained contact, single throw. Termination Style: Front wired screw & clamp. Max Wire Size: #10 AWG. Horsepower rated for motor loads per UL 508: 120V/AC 3 HP, 240V/AC 7.5 HP, 480V/AC 15 HP, 600V/AC 15 HP. CWDAH7810UD 30A 600VAC, 3-Phase, Motor Control Switch, 2-Position, Maintained Contact, Single Throw Does Not Contain Clearance Items 86

89 Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Contactors - Coils - Starters Definite Purpose Contactors & Coils Contactor Enclosed NEMA-1 C-H C25DGD C-HC25DGD330A Cutler-Hammer C25DGD Closed Contactors Type C25, NEMA type 1 enclosed definite purpose contactors. UL recognized/csa certified 30A, 3-Pole, Definite Purpose Enclosed Contactor, AC Coil Voltage V 50/60Hz Contactor Enclosed NEMA-1 C-H C799B18 Electrical - Distribution & Controls Cutler-Hammer C799B18 Enclosure NEMA 1 Separate Freedom Type enclosure for definite purpose contactors and starters. For 15 through 50A, two and three-pole Motor Controls - Contactors - Switches - Disconnects C-HC799B18 Contactors Open C-H Type C25 Enclosure Only, for 15A through 50A, 2 & 3-Pole Definite Purpose Contactors & Starters Cutler-Hammer C25 Open Contactors Type C25 open type, two and three pole, definite purpose contactors. Dual-rated with inductive and resistive ratings as well as horsepower and kilowatt ratings. Furnished with pressure plated and quick connect terminals on 15, 25 and 30A devices and with box lugs and quick connect terminals on 40, 50, 60 and 75A. UL recognized/csa certified. RoHS compliance (15A to 50A only) C-HC25DND225A C-HC25DND225B C-HC25DND230A C-HC25DND230B C-HC25DND325A C-HC25DND330A C-HC25DND330B C-HC25DND330T C-HC25DNF340A C-HC25DNF340B C-HC25FNF360B 25A Inductive Full Load, 35A Resistive per Pole, 2-Pole, Open Contactor, V 50/60Hz 25A Inductive Full Load, 35A Resistive per Pole, 2-Pole, Open Contactor, V 50/60Hz 30A Inductive Full Load, 40A Resistive per Pole, 2-Pole, Open Contactor, V 50/60Hz 30A Inductive Full Load, 40A Resistive per Pole, 2-Pole, Open Contactor, V 50/60Hz 25A Inductive Full Load, 35A Resistive per Pole, 3-Pole, Open Contactor, V 50/60Hz 30A Inductive Full Load, 40A Resistive per Pole, 3-Pole, Open Contactor, V 50/60Hz 30A Inductive Full Load, 40A Resistive per Pole, 3-Pole, Open Contactor, V 50/60Hz 30A Inductive Full Load, 40A Resistive per Pole, 3-Pole, Open Contactor, 24VAC 50/60Hz 40A Inductive Full Load, 50A Resistive per Pole, 3-Pole, Open Contactor, V 50/60Hz 40A Inductive Full Load, 50A Resistive per Pole, 3-Pole, Open Contactor, V 50/60Hz 60A Inductive Full Load, 75A Resistive per Pole, 3-Pole, Open Contactor, V 50/60Hz Contactors Open Compact C-H C25BNB Cutler-Hammer C25BNB Open Contactors Type C25, open type, 2-pole Definite Purpose Contactors feature a compact, efficient design with a low VA coil and straight-through wiring. UL recognized/csa certified. RoHS Compliance C-HC25BNB220A 20A, 2-Pole, Definite Purpose Compact Open Contactor, AC Coil Voltage V 50/60Hz Does Not Contain Clearance Items 87

90 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Contactors - Coils - Starters Definite Purpose Contactors & Coils Parts - AC Coils 15-40A C-H C-H C-H C-H C-H Cutler-Hammer AC Coils AC coils for definite purpose contactors and starters. 15, 25, 30 & 40A - two and three-pole (Series D1) Parts - AC Coils 60-75A C-H A, 2 & 3-Poles, 110/120V, Type C25, AC Coil Replacement, Coil Suffix A 15-40A, 2 & 3-Poles, 208/240V, Type C25, AC Coil Replacement, Coil Suffix B 15-40A, 2 & 3-Poles, 440/480V, Type C25, AC Coil Replacement, Coil Suffix C 15-40A, 2 & 3-Poles, 24VAC, Type C25, AC Coil Replacement, Coil Suffix T Electrical - Distribution & Controls Cutler-Hammer AC Coils AC Coils for definite purpose contactors and starters. 60 and 75A - two and three pole; 25, 30, 40A - four pole C-H A 2 & 3-Pole, or & 40A 4-Pole Definite Purpose AC Coil, 104/120V, Coil Suffix A C-H A 2 & 3-Pole, or & 40A 4-Pole Definite Purpose AC Coil, 208/240V, Coil Suffix B, Class B, 130 C C-H A 2 & 3-Pole, or & 40A 4-Pole Definite Purpose AC Coil, 24V, Coil Suffix T Parts - AC Replacement Coil for Lighting Cont. C-H Magnetic Coils - C-H Magnetic coils for base contactor. For C30 mechanically held lighting contactor C-H Magnetic Coil V 60Hz / 240V 50Hz, for Lighting Contactor Lighting Contactors Cutler-Hammer Contactor Lighting C-H C30CNE20A0 Cutler Hammer C30CNE20A0 Lighting Contactor This electrically held base contactor contains a 2NO power pole as standard and will allow the addition of power poles to build an electrically held contactor up to 12 poles maximum. C-HC30CNE20A0 Electrically Held Base Lighting Contactor, 30A, 2-NO Poles, V 60Hz/ 110V 50Hz Does Not Contain Clearance Items 88

91 Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Contactors - Coils - Starters Lighting Contactors Cutler-Hammer Ltg. Contactor Power Pole C-H C320PRP C-HC320PRP2 Cutler-Hammer C320PRP Power Poles For use with C30 modular style lighting contactor. Power poles are available in both single pole and double pole versions. Can be used as N.O. or N.C. Power Pole Kit for Lighting Contactor, Double Pole NEMA Contactors / Starters & Parts Auxiliary Contacts - Cutler-Hammer Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects Auxiliary Contacts - Cutler-Hammer For NEMA Freedom Series starters and contactors and/or definite purpose contactors and starters C-HC320KG1 C-HC320KG2 C-HC320KG3 C-HC320KGS1 C-HC320KGS2 C-HC320KGS20 C-HC320KGS3 C-HC320KGS31 C-HXTCEXFBG11 1NO, Auxiliary Contact w/ Standard Pressure Plate Terminals, Freedom Series, 1 Pole, Nema 1, 10A, Side Mount 1NC, Auxiliary Contact w/ Standard Pressure Plate Terminals, Freedom Series, 2 Pole, Nema 1, 10A, Side Mount 1NO-1NC, Auxiliary Contact w/ Standard Pressure Plate Terminals, Freedom Series, 2 Pole, Nema 1, 10A, Side Mount 1NO, Auxiliary Contact, Freedom Series, Nema 00-2, 10A, 1 Pole, Side Mount 1NC, Auxiliary Contact, Freedom Series, Nema 00-2, 10A, 2 Pole, Side Mount 1NO, Auxiliary Contact, Freedom Series, Nema 3-5, 10A, 2 Pole, Side Mount 1NO-1NC, Auxiliary Contact, Freedom Series, Nema 00-2, 10A, 3 Pole, Side Mount 1NO, Auxiliary Contact, Freedom Series, Nema 00-2, 10A, 3 Pole, Side Mount 1NO-1NC, Auxiliary Contact, XT Series, Frame D-G, 2 Pole, Nema 1-4, 16A, Front Mount Freedom Full Voltage Control Starters C-H ECN05 Cutler-Hammer ECN05 NEMA Starters Freedom full voltage control non-combination starters. 3-Phase magnetic. 600V max. Type 1 general purpose enclosure C-HECN0501AAA C-HECN0511AAA C-HECN0521AAA C-HECN0521BAA C-HECN0531AAA NEMA Starter size 0, 3-Phase, 120V Magnetic Coil, Type 1 Enclosure NEMA Starter Size 1, 3-Phase, 120V Magnetic Coil, Type 1 Enclosure NEMA Starter size 2, 3-Phase, 120V Magnetic Coil, Type 1 Enclosure NEMA Starter Size 2, 3-Phase, 240V Magnetic Coil, Type 1 Enclosure NEMA Starter Size 3, 3-Phase, 120V Magnetic Coil, Type 1 Enclosure Does Not Contain Clearance Items 89

92 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Contactors - Coils - Starters NEMA Contactors / Starters & Parts Freedom Heater Pack Replacement Series A &B C-H H20 C-HH2005B3 C-HH2006B3 C-HH2007B3 C-HH2008B3 C-HH2009B3 C-HH2010B3 C-HH2011B3 C-HH2012B3 C-HH2013B3 C-HH2014B3 C-HH2015B3 C-HH2016B3 C-HH20193 C-HH20203 C-HH20213 C-HH20223 C-HH20233 C-HH20243 Cutler-Hammer Heater Packs Standard Trip, Class 20 Heater. Heater packs H2001B to H2017B are to be used only with Series B overload relays Catalog Numbers C306DN3B and C306GN3B. The load lugs are built into the overload relay base to allow load wiring prior to heater pack installation. H2001B-3 to H2014B-3: For Use with NEMA Sizes 00-0 Series C, NEMA Sizes 1-2 Series B; IEC Sizes A-F Series C, IEC Sizes G-K Series B. H2015B-3 to H2017B-3: For Use with NEMA Size 2, IEC Sizes G-K Only, Series B. H to H2024-3: For Use with NEMA Sizes 3-4, IEC Sizes L-N Only-Series A. Comes 3 in a pack Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 32A or 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series B 75A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series A 105A or 144A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series A 105A or 144A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series A 105A or 144A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series A 105A or 144A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series A 105A or 144A Overload Relays, Standard Trip (3PK) Heater Packs for use with Series A 105A or 144A Overload Relays, Standard Trip (3PK) Freedom Non-Combo Cover Control Kit C-H C600M1 Electrical - Distribution & Controls Cover Control Kit - C-HC600M1 Type 1 non-combination cover control with STOP/START oval pushbuttons. Non-reversing. Pushbuttons are momentary type. Field convertible selector switches from momentary to maintained operation and vice versa. Cover control kits include metallic enclosure with starters, hardware, M22 pushbuttons, bracket and pre-wired wire harnesses C-HC600M1 Type 1 Cover Control Kit for Non-Combination Starters, START/STOP Oval Pushbuttons Freedom Overload Relay Contactor C-H C306DN3B Cutler-Hammer C306DN3B Overload Relay Contactor Freedom Series Open type NEMA size 00, 0 Contactor. 32A, 3-Poles. Selectable manual or automatic reset opertion. Series B overload relays have load lugs built into relay base and will only accept Series B heater packs. UL Listed, CSA Certified C-HC306DN3B 32A, 3-Pole, Thermal Overload Relay Contactor, Open, NEMA Size 00, 0 Does Not Contain Clearance Items 90

93 Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Contactors - Coils - Starters NEMA Contactors / Starters & Parts Freedom Overload Relay Contactor C-H C306GN3B Cutler-Hammer C306GN3B Overload Relay Contactor Freedom Series Open type NEMA size 1, 2 Contactor. 75A, 3-Poles. Selectable manual or automatic reset opertion. Series B overload relays have load lugs built into relay base and will only accept Series B heater packs. UL Listed, CSA Certified C-HC306GN3B 75A, 3-Pole, Thermal Overload Relay Contactor, Open, NEMA Size 1, 2 Freedom Replacement Coils C-H Cutler-Hammer Replacement Coils Replacement coil for NEMA size 1 and 2 Freedom Starters Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects C-H KIT C-H KIT C-H KIT C-H KIT Replacement Coil, 120V, NEMA Size 1 & 2, for Freedom Starters Replacement Coil, 240V. NEMA Size 1 & 2, for Freedom Starters Replacement Coil, 24V, NEMA Size 1 & 2, for Freedom Starters Replacement Coil, 208V, NEMA Size 1 & 2, for Freedom Starters Freedom Replacement Magnetic Coils & Coil Kits C-H 9-2 Cutler-Hammer Replacement Coils - Freedom Series IEC Renewal Parts Magnet Coils. See contactor/starter nameplate to determine series A1, B1 or C1 C-H C-H C-H KIT C-H KIT NEMA size 1 or 2, series A1 or B1, 480V 60Hz Magnetic Coil, Coil Suffix C NEMA size 3, 120V 60Hz or 110V 50Hz Magnetic Coil, Coil Suffix A NEMA size 3, 240V 60Hz or 220V 50Hz Magentic Coil Kit, Coil Suffix B NEMA size 3, 480V 60Hz or 440V 50Hz Magnetic Coil Kit, Coil Suffix C C-H NEMA size 0, 120V 60Hz or 110V 50Hz, series B1 or C1, Magnetic Coil, Coil Suffix A - Dim.: 2.1H x 1.8W x 1.8D C-H C-H NEMA size 0, 240V 60Hz or 220V 50Hz, series B1 or C1, Magnetic Coil, Coil Suffix B NEMA size 0, 480V 60Hz or 440V 50Hz, series B1 or C1, Magnetic Coil, Coil Suffix C Freedom Starter-Contactor Control - C-H C400GK1 Freedom Starter-Contactor Control - Cutler-Hammer C400GK1 Type NEMA 1 enclosure, non-reversing, starter/contactor cover control. Start/Stop pushbuttons with red RUN pilot light with red RUN/ Green OFF lights. For Non-combination NEMA 00-4, IEC: A-M, Freedom Series 3-Phase Magnetic Starters, enclosed C-HC400GK1 Type NEMA 1 Starter/Contactor Control Kit, Start/Stop Pushbuttons, Size NEMA 00-4 Does Not Contain Clearance Items 91

94 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Contactors - Coils - Starters NEMA Contactors / Starters & Parts Manual Motor Starter Heater C-H FH32 C-HFH32 Eaton, Cutler-Hammer FH32 Heater Heater for Type A and B Overload Relays, size 0, 1, & 2 Manual Motor Starter. Range: Full Load Current of Motor (Amperes). Heater should be selected on the basis of the actual full load current and service factor as shown on the motor nameplate or in the manufacturer's published literature Heater for Thermal Types A and B Overload Relays on Size 0, 1, & 2 Manual Motor Starters, Range Full Load Amp. Manual Motor Starter Switch 2P C-H B230AN Electrical - Distribution & Controls Cutler-Hammer B230AN Manual Motor Switch 2-Pole Manual Motor Switch without overload. Open, no enclosure. Rated at 30A. Max. HP Ratings: 120V, 240V. Provides manual control of single phase motors where overload protection is not required or provided separately C-HB230AN NEMA Manual Motor Starter Switch Toggle, 2-Pole, w/out Overload Manual Operated Starter C-H B100S0CA Cutler-Hammer B100S0CA Manual Operated Starter NEMA Size M-0 Manual Starter with NEMA 1 general purpose enclosure. Type B100 non-reversing 3-Pole, for polyphase motors. Tapped for 1" conduit on each end. Optional pushbutton operator included C-HB100S0CA NEMA Size M-0 Manual Starter, 3-Pole, NEMA 1 Enclosure w/ Pushbutton Operator MSH8-8A Heater for MS Starters Cutler-Hammer Manual Starter Heater C-HMSH8-8A Overload heater for MS series starters. Motor full load current: C-HMSH8-8A Manual Starter Heater for Motor Full Load Current MST01 Manual Motor Starter Switch 1P Cutler-Hammer Cutler-Hammer MST01 Manual Motor Starter Open type, toggle operated, manual motor starter for 1-phase motors. Provides manual control and overload protection. 1- Phase, 1-Pole, 1 120/240V 277Vac, 1/4 120/240 Vdc, 1/4 32 Vdc. (does not include plug-in heater) C-HMST01 NEMA Manual Motor Starter Switch Toggle, 1-Pole, 1-Phase, 120/240, 277V Does Not Contain Clearance Items 92

95 Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Disconnect Safety Switches Safety Sw-Disconnects - Cutler-Hammer 120/240V Non-Fusible, 1-Throw - C-HDG-Ux General Duty Non-Fusible Safety Switches - C-HDG-Ux 120/240V or 240V general duty, non-fusible, single throw safety switches. Non-fusible safety switches provide a means to manually connect or disconnect the equipment from the power source. Suitable for service entrance applications unless otherwise noted. Horsepower rated. Bolt-on hub provision provided for general-duty switches in a NEMA 3R enclosure. UL listed C-HDG221UGB 30A Safety Switch, 2-Pole, 2-Wire, 120/240V, 1PH, Non-Fusible, Single Throw, NEMA 1 C-HDG221URB 30A Safety Switch, 2-Pole, 2-Wire, 120/240V, 1PH, Non-Fusible, Single Throw, NEMA 3R C-HDG222UGB 60A Safety Switch, 2-Pole, 2-Wire, 120/240V, 1PH, Non-Fusible, Single Throw, NEMA 1 C-HDG222URB C-HDG223URB 60A Safety Switch, 2-Pole, 2-Wire, 120/240V, 1PH, Non-Fusible, Single Throw, NEMA 3R 100A Safety Switch, 2-Pole, 2-Wire, 120/240V, 1PH, Non-Fusible, Single Throw, NEMA 3R C-HDG321UGB 30A Safety Switch, 3-Pole, 3-Wire, 120/240V, 3PH, Non-Fusible, Single Throw, NEMA 1 C-HDG321URB 30A Safety Switch, 3-Pole, 3-Wire, 120/240V, 3PH, Non-Fusible, Single Throw, NEMA 3R C-HDG322UGB 60A Safety Switch, 3-Pole, 3-Wire, 120/240V, 3PH, Non-Fusible, Single Throw, NEMA 1 C-HDG322URB C-HDG323URB C-HDG324URK 240V, Fusible, 1-Throw - C-HDG-Nx 60A Safety Switch, 3-Pole, 3-Wire, 120/240V, 3PH, Non-Fusible, Single Throw, NEMA 3R 100A Safety Switch, 3-Pole, 3-Wire, 240V, 3PH, Non-Fusible, Single Throw, NEMA 3R 200A Safety Switch, 3-Pole, 3-Wire, 240V, 3PH, Non-Fusible, Single Throw, NEMA 3R Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects General Duty Fusible Safety Switches - C-HDG-N 240 Vac general-duty, fusible, single throw safety switches. Fusible safety switches provide a means to manually open and close a circuit and overcurrent protection by using customer-installed fuses. Suitable for service entrance applications unless otherwise noted. Horsepower rated. Bolt-on hub provision provided for general-duty switches in a NEMA 3R enclosure. UL listed C-HDG221NGB 30A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Single Throw, NEMA 1 C-HDG221NRB 30A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Single Throw, NEMA 3R C-HDG222NGB 60A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Single Throw, NEMA 1 C-HDG222NRB 60A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Single Throw, NEMA 3R C-HDG223NGB 100A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Single Throw, NEMA 1 C-HDG223NRB 100A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Single Throw, NEMA 3R C-HDG224NGK 200A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Single Throw, NEMA 1 C-HDG224NRK 200A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Single Throw, NEMA 3R C-HDG225NRK 400A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Single Throw, NEMA 3R C-HDG321NGB 30A Safety Switch, 3-Pole, 4-Wire, 240V, Fusible, Single Throw, NEMA 1 C-HDG321NRB 30A Safety Switch, 3-Pole, 4-Wire, 240V, Fusible, Single Throw, NEMA 3R C-HDG322NGB 60A Safety Switch, 3-Pole, 4-Wire, 240V, Fusible, Single Throw, NEMA 1 C-HDG322NRB 60A Safety Switch, 3-Pole, 4-Wire, 240V, Fusible, Single Throw, NEMA 3R C-HDG323NGB 100A Safety Switch, 3-Pole, 4-Wire, 240V, Fusible, Single Throw, NEMA 1 C-HDG323NRB 100A Safety Switch, 3-Pole, 4-Wire, 240V, Fusible, Single Throw, NEMA 3R C-HDG324NGK 200A Safety Switch, 3-Pole, 4-Wire, 240V, Fusible, Single Throw, NEMA 1 C-HDG324NRK 200A Safety Switch, 3-Pole, 4-Wire, 240V, Fusible, Single Throw, NEMA 3R C-HDG325NGK 400A Safety Switch, 3-Pole, 4-Wire, 240V, Fusible, Single Throw, NEMA 1 Does Not Contain Clearance Items 93

96 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Disconnect Safety Switches Safety Sw-Disconnects - Cutler-Hammer 240V, Fusible, 1-Throw Plug Type C-HDP-Nx General Duty Plug-Type Fusible Safety Switch - C-HDP-Nx 120/240 Vac general-duty, fusible, plug type, single throw safety switches. Plug type switches do not have an interlock which prevents door from being opened when switch in in the ON position. Fusible safety switches provide a means to manually open and close a circuit and overcurrent protection by using customer-installed fuses. Suitable for service entrance applications unless otherwise noted. Horsepower rated. UL Listed C-HDP221NGB 30A Safety Switch, 2-Pole, 3-Wire, 240V, Fusible, Plug Type Fuse, Single Throw, NEMA 1 600V, HD Fusible, 1-Throw - C-HDHx Electrical - Distribution & Controls Heavy Duty Fusible Safety Switches - C-HDHx 600 Vac heavy-duty, fusible, single throw safety switches. Fusible safety switches provide a means to manually open and close a circuit and overcurrent protection by using customer-installed fuses. Suitable for service entrance use, except 1200 ampere on 480Y/277 or 600Y/347 grounded wye systems power NEC and , and 4-pole switches. Horsepower rated. UL listed C-HDH361FGK 30A - Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 1 C-HDH361NGK 30A - Heavy Duty Safety Switch, 3-Pole, 4-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 1 C-HDH361NRK 30A - Heavy Duty Safety Switch, 3-Pole, 4-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 3R C-HDH362FGK 60A - Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 1 C-HDH362NGK 60A - Heavy Duty Safety Switch, 3-Pole, 4-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 1 C-HDH362NRK 60A - Heavy Duty Safety Switch, 3-Pole, 4-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 3R C-HDH363FGK 100A - Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 1 C-HDH363FRK 100A - Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 3R C-HDH363NGK 100A - Heavy Duty Safety Switch, 3-Pole, 4-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 1 C-HDH364FRK 200A - Heavy Duty Safety Switch, 3-Pole, 2-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 3R C-HDH364NGK 200A - Heavy Duty Safety Switch, 3-Pole, 4-Wire, 600V, 3PH, Fusible, Single Throw, NEMA 1 600V, HD Non-Fusible, 1-Throw - C-HDH-Ux Heavy Duty Non-Fusible Safety Switches - C-HDH-Ux 600 Vac heavy-duty, non-fusible, single throw safety switches. Non-fusible safety switches provide a means to manually connect or disconnect the equipment from the power source. Suitable for service entrance use, except 1200 ampere on 480Y/277 or 600Y/347 grounded wye systems power NEC and , and 4-pole switches. Horsepower rated. UL listed C-HDH361UGK 30A Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Non-Fusible, Single Throw, NEMA 1 C-HDH361URK 30A Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Non-Fusible, Single Throw, NEMA 3R C-HDH362UGK 60A Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Non-Fusible, Single Throw, NEMA 1 C-HDH362URK 60A Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Non-Fusible, Single Throw, NEMA 3R C-HDH363UGK 100A Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Non-Fusible, Single Throw, NEMA 1 C-HDH363URK 100A Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Non-Fusible, Single Throw, NEMA 3R C-HDH364UGK 200A Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Non-Fusible, Single Throw, NEMA 1 C-HDH364URK 200A Heavy Duty Safety Switch, 3-Pole, 3-Wire, 600V, 3PH, Non-Fusible, Single Throw, NEMA 3R Does Not Contain Clearance Items 94

97 Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Disconnect Safety Switches Safety Sw-Disconnects - Cutler-Hammer Neutral Kits for Safety Switches - C-H C-HDG200NK C-HDH030NK C-HDH100NK Cutler-Hammer Neutal Kits Neutral Kits for use with DG (General Duty) and/or DH (Heavy Duty) Safety Switches. Safety Switch Hubs - C-HDSx Neutral Kit for 200 Amp DG (general duty) or DH (heavy duty) Safety Switches (NEMA 1, 3R Enclosures) Neutral Kit for 30 to 60 Amp DH (heavy duty) Safety Swiches Neutral Kit for 100 Amp DH (heavy duty) Safety Swiches Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects Hubs for Safety Switches - C-HDSx Plate type hubs for NEMA 3R enclosures. Small size is for general-duty, heavy-duty, double throw through 100A. Large size if for general-duty, heavy-duty, double throw 200A C-HDS100H1 C-HDS125H1 C-HDS150H1 C-HDS200H1 C-HDS200H2 C-HDS250H2 C-HDS300H2 1" - Rainproof Plate Conduit/Hub Plate Hub, Double Throw Used w/ DG, DH, DT Through 100A, Group 1, NEMA 3R - 3" W X 2" H X 3" L 1-1/4" - Rainproof Plate Conduit/Hub, Double Throw Used w/ DG, DH, DT Through 100A, Group 1, NEMA 3R - 3" W X 2" H X 3" L 1-1/2" - Rainproof Plate Conduit/Hub, Double Throw Used w/ DG, DH, DT Through 100A, Group 1, NEMA 3R - 3" W X 1.25" H X 2.75" L 2" - Rainproof Plate Conduit/Hub, Double Throw Used w/ DG, DH, DT Through 100A, Group 1, NEMA 3R - 3" W X 2" H X 3" L 2" - Rainproof Plate Conduit/Hub, Double Throw Used w/ DG, DH, DT Through 200A, Group 2, NEMA 3R - 5" W X 2" H X 5" L 2-1/2" - Rainproof Plate Conduit/Hub, Double Throw Used w/ DG, DH, DT Through 200A, Group 2, NEMA 3R - 5" W X 2" H X 5" L 3" - Rainproof Plate Conduit/Hub Plate Hub, Double Throw Used w/ DG, DH, DT Through 200A, Group 2, NEMA 3R - 5" W X 2" H X 5" L Cutler-Hammer - Limit Switches Limit Switches Cutler-Hammer E50 Limit Switch Assy. 1-Pole C-H E50AR1 Cutler-Hammer E50 Plug-in Limit Switch C-HE50AR1 Heavy duty standard plug-in switch includes switch body, head and receptacle. Single pole 5 terminal receptacle. Side rotary head, standard spring return (requires an operating lever). 1NO-1NC. 600V max. rating C-HE50AR1 600V Limit Switch, Plug-in, Side Rotary, 1NO-1NC Does Not Contain Clearance Items 95

98 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Limit Switches Limit Switches Cutler-Hammer E50 Operating Head C-H E50DR1 C-HE50DR1 Cutler-Hammer Operating Head C-HE50DR1 E50 Series operating head for heavy-duty plug-in limit switches. Side rotary (requires an operating lever). Standard spring return, CW (clockwise) and CCW (counterclockwise) operation, easily convertible to CW only or CCW only operation. 90 total travel E50 Operator Arm C-H E50KL201 Operating Head for Limit Switch, Side Rotary Electrical - Distribution & Controls Cutler-Hammer Roller Type Operator C-HE50KL201 Adjustable roller type stainless steel operator. For rotary head limit switches: E50 Plug-In, E50 6P+, and Nylatron type roller. Length: 1" " C-HE50KL201 E50 Switch Body 1-Pole C-HE50SA Roller Arm Operator for Limit Switch, Adjustable Cutler-Hammer Body for Limit Switch C-HE50SA Switch body without indicating light for E50 Series heavy-duty plug-in limit switches. Single-pole 1NO-1NC C-HE50SA Limit Switch Body, 1-Pole, 1NO-1NC E50 Switch Receptacle 1-Pole C-H E50RA Cutler-Hammer Receptacle for Limit Switch C-HE50RA Surface mount, single-pole, 5 terminal receptacle for E50 Series heavy-duty plug-in limit switches. 1/2 NPT conduit entrance, front or rear mounting C-HE50RA Limit Switch Receptacle, 1-Pole, 5-Terminal, Surface Mount Does Not Contain Clearance Items 96

99 Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer - Transfer Switches Transfer Switches - Cutler-Hammer Manual 240V, Dbl-Throw - C-HDTx C-HDT223URKNPS C-HDT224URKNPS General Duty Double Throw Safety Switch - C-HDTx 240 Vac general-duty non-fusible, double throw safety / transfer switch. Performs the same function as a safety switch by opening and closing a circuit, however its primary use is to transfer service from a normal power source to an alternate source, or to switch from one load circuit to another. Horsepower rated. Non-Fusible, 2-Pole, 3-Wire, 240 Vac, 250 Vdc, Solid Neutral. Suitable for service entrance use with neutral kit installed. Suitable for use as a manually operated switch. Quick-make, quick-brake operating mechanism. UL listed 100A Safety/Trans. Switch, Manual, Double Throw DPDT, Non-Fusible, 2-Pole, 3-Wire, 240V, 1PH, NEMA 3R 200A Safety/Trans. Switch, Manual, Double Throw DPDT, Non-Fusible, 2-Pole, 3-Wire, 240V, 1PH, NEMA 3R Hubbell - Switches & Switch Enclosures 30A Motor Control Switch HBL7810D Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects Motor Control Switch - HBL7810D AC Manual motor controller, standard toggle switch. 30 Amp, 600V AC Max, 3-Pole. #10 brass terminal screw. Clamping plate for secure back or side wiring. UL/CSA listed HBL7810D 30A Switched Enclosure HBLDS3 30A, 600V AC, 3-Pole, Manual Motor Controller, Standard Toggle Switch Circuit-Lock Disconnect Switch - HBLDS3 Three Pole unfused circuit-lock disconnect switch enclosure. 30 Amp, 600V AC. Adjustable mounting feet. Lockable handle to meet OSHA Lockout Tagout regulations. Nonmetallic enclosure - nonconducting, internal frame automatically bonds all grounds. UL/CSA Listed HBLDS3 60A Switched Enclosure HBLDS6 30A, 600V AC, 3-Pole Unfused, Circuit-Lock Disconnect Switch Enclosure Circuit-Lock Disconnect Switch - HBLDS6 Three pole unfused circuit-lock disconnect switch enclosure. 60 Amp, 600V AC. Adjustable mounting feet. Lockable handle to meet OSHA Lockout Tagout regulations. Nonmetallic enclosure - nonconducting, internal frame automatically bonds all grounds. UL/CSA Listed HBLDS6 60A, 600V AC, 3-Pole Unfused, Circuit-Lock Disconnect Switch Enclosure Does Not Contain Clearance Items 97

100 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Hubbell - Switches & Switch Enclosures Auxiliary Contact - HBLAC1 HBLAC1 Hubbell Auxiliary Contact - HBLAC1 Auxiliary contact for 30,60 and 100A switches. "Break After Main Break". 1 Set of n/o & n/c contacts. Auxiliary Contact for 30, 60 and 100A Switches "Break After Main Break" Square D - Busway Plug-in Switch Busway Plug-In Units I-Line II Busy Plug-In Units - Square D PQx Electrical - Distribution & Controls I-Line II Busway Plug-in Units - Square D PQx Fusible type, floor-operable quick-make, quick-break. "Hook Swing" Mounting. Plug-in connection. Provisions for installing Class J fuses are included in 30 through 600A fusible devices QOPQ3603G QOPQ3606G QOPQ3610G QOPQ3620G 30A Plug-In Busway Switch, 600Vac, 3-Pole, 3 Fuse w/ Ground 60A Plug-In Busway Switch, 600Vac, 3-Pole, 3 Fuse w/ Ground 100A Plug-In Busway Switch, 600Vac, 3-Pole, 3 Fuse w/ Ground 200A Plug-In Busway Switch, 600Vac, 3-Pole, 3 Fuse w/ground Square D - Contactors & Starters NEMA Combination Starter NEMA Combination Starter QO 8538SBG13V02S Square D 8538SBG13V02S Combination Starter Type S non-reversing, 3-Pole, 3-Phase, combination starter. Maximum votage rating: 600 Vac. Fuse Clip Amperes: 30A. Horsepower rating (3-Phase): 5HP@460/575V. Nema size: 0. Enclosure: Nema 1 surface mount. Disconnect type: Fuseible disconnect switch. Overload: thermal - melting alloy. Operating voltage: 120V@60 Hz - 110Vac@50Hz. Separate control circuit QO8538SBG13V02S NEMA Type Accessories & Parts Coil QO V Combination Starter, Size 0 Nema 1 Enclosure, 3-Pole Polyphase, 120V, w/ Separate Contol Circuit Square D Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating 24V 60Hz. Type number: Size 00 - Type SA (Series A), Size 0 - Type SB, Size 1 - Type SC. Number of poles: All devices QO V 60Hz, 30A, AC Magnetic Coil for Contactors & Starters Does Not Contain Clearance Items 98

101 Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters NEMA Type Accessories & Parts Coil QO V QO Square D Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 120V 60Hz/ V 50Hz. Type number: Size 00 - Type SA (series A), Size 0 - Type SB, Size 1 - Type SC. Number of Poles: All devices Coil QO V 120V 60Hz, 30A, AC Magnetic Coil for Contactors & Starters Electrical - Distribution & Controls Square D Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 208V 60Hz. Type number: Size 00 - Type SA (Series A), Size 0 - Type SB, Size 1 - Type SC. Number of poles: All devices Motor Controls - Contactors - Switches - Disconnects QO Coil QO V 208V 60Hz, 30A, AC Magnetic Coil for Contactors & Starters Square D Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 240V 60Hz/220V 50Hz. Type number: Size 00 - Type SA (Series A), Size 0 - Type SB, Size 1 - Type SC. Number of poles: All devices QO Coil QO V 240V 60Hz, 30A, AC Magnetic Coil for Contactors & Starters Square D Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 480V 60Hz/440V 50Hz. Type number: Size 00 - Type SA (Series A), Size 0 - Type SB, Size 1 - Type SC. Number of poles: All devices QO Coil QO V 480V 60Hz, 30A, AC Magnetic Coil for Contactors & Starters Square D Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 120V 60Hz/ V 50Hz. Equipment to be serviced: Size 2 & 60A - Type SD & SP. No. of poles: 2 or 3 QO V 60Hz, 60A AC Magnetic Coil for Contactors & Starters Does Not Contain Clearance Items 99

102 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters NEMA Type Accessories & Parts Coil QO V QO Square D Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 240V 60Hz/220V 50Hz. Equipment to be serviced: Size 2 & 60A - Type SD & SP. No. of poles: 2 & 3 Coil QO V 240V 60Hz/220V 50Hz, 60A AC Magnetic Coil for Contactors & Starters Electrical - Distribution & Controls Square D Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 480V 60Hz / 440V 50Hz. Equipment to be serviced: Size 2 & 60A - Type SD & SP. No. of poles: 2 & 3 QO Coil QO V 480V 60Hz/440V 50Hz, AC Magnetic Coil for Contactors & Starters Square D Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 240V 60Hz / 220V 50Hz. Equipment to be serviced: Size 3 & 100A - Type DPA12_, SE, SQ & SYD138. No of Poles: 2 or 3 QO Coil QO 9998L44-120V-110V 240V 60Hz/220V 50Hz, 100A, AC Magnetic Coil for Contactors & Starters Square D L44 Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 120V 60Hz / V 50Hz. Equipment to be serviced: Size 30A - Type L & LX. Number of Poles: 2-6 QO9998L44 Coil QO 9998L55-277V 120V 60Hz / 110V-115V 50Hz, AC Magnetic Coil for Contactors & Starters Square D L55 Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 277V 60Hz. Equipment to be serviced: Size 30A - Type L, 2-6 Poles & Type LX, 2-4 Poles QO9998L55 277V 60Hz, AC Magnetic Coil for Contactors & Starters Does Not Contain Clearance Items 100

103 Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters NEMA Type Accessories & Parts Coil QO 9998SAC54-240V QO9998SAC54 Square D SAC54 Replacement Coil Replacement AC Magnet Coil for Magnetic Contactors and Starters. Coil rating: 240V 60Hz / 220V 50Hz. Equipment to be serviced: Size 00 - Type SA (Series B). Poles: All Contact Kits Auxiliary QO 9999D 240V 60Hz / 220V 50Hz, AC Magnetic Coil for Contactors & Starters Square D 9999D Auxiliary Contact Kits Auxiliary Contacts for Class 8910 and 8911 Definite Purpose Contactors and Starters Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects QO9999D01 Auxiliary Contact Kit for Class 8910 Definate Purpose Contactors & Starters - 1 N.C., 50-90A QO9999D10 Auxiliary Contact Kit for Class 8910 Definate Purpose Contactors & Starters - 1 N.O., 50-90A QO9999D11 Auxiliary Contact Kit for Class 8910 Definate Purpose Contactors & Starters - 1 N.O./ 1 N.C., 50-90A QO9999DD01 Auxiliary Contact Kit for Class 8910 Definate Purpose Contactors & Starters - 1 N.C. Series C, 20-40A QO9999DD10 Auxiliary Contact Kit for Class 8910 Definate Purpose Contactors & Starters - 1 N.O. Series C, 20-40A QO9999DD11 Auxiliary Contact Kit for Class 8910 Definate Purpose Contactors & Starters - 1 N.O./ 1 N.C. Ser C, 20-40A Contact Kits Auxiliary QO 9999SX Square D SX Auxiliary Contact Kits Class 9999 Contactor & Starter Auxiliary Contact Kits. For use with Type S Contactors and Starters QO9999SX11 QO9999SX6 QO9999SX7 QO9999SX8 Contact Kits QO 9998SL Internal Contact Non-Convertible, 1-N.O. Contact - for Type SA-SD Size 00 thru 2 Contactors & Starters External Contact Field Convertible, 1-N.O. Contact - for Type SA-SJ Size 00 thru 7 Contactors & Starters External Contact Field Convertible, 1-N.C. Contact - for Type SA-SJ Size 00 thru 7 Contactors & Starters External Contact Field Convertible, 1-N.O. and 1-N.C. Isolated Contacts - for Type SA-SJ Size 00 thru 7 Contactors & Starters Square D SL Contact Kits Class 9998 Magnetic Contactor and Starter Contact Kits for Present Designs. They contain the necessary moveable and stationary contacts, contact springs (when required - Nema size 3 and above do not include contact springs, and springs are not available), and additonal hardware required to service the devices. When servicing devices having more poles than contained in the corresponding kit, it may be necessary to order an additional kit QO9998SL2 QO9998SL3 QO9998SL4 Magnetic Contactor and Starter Contact Kit for Type SB Size 0, 3-Pole Magnetic Contactor and Starter Contact Kit for Type SC Size 1 & 1P, 3-Pole Magnetic Contactor and Starter Contact Kit for Type SD Size 2, 3-Pole Does Not Contain Clearance Items 101

104 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters NEMA Type Accessories & Parts Contact Kits QO 9998SL QO9998SL7 External Overload Reset QO 9066RA1 QO9066RA1 Magnetic Contactor and Starter Contact Kit for Type SE Size 3, 3-Pole Square D RA1 External Reset Mechanism Kit One rod external reset for use with OEM kit for commercial enclosures. For Nema 1, 4 and 12 enclosures Overload Relay QO 9065SFB20 Type RA External Reset Mechanism Kit with 1 Rod Electrical - Distribution & Controls Square D SFB20 Overload Relay Solid State Overload Relay for Square D type S Starter. For separate mounting. 600 Vac Maximum. Open Type, Trip Class 10/20. Full Load Current Range: A. Features 3 to 1 adjustment for trip current, phase loss and unbalance protection, switch selectable trip class, Class II ground fault detection, and direct replacement for Type S melting alloy. Purchase Lugs separately QO9065SFB20 Solid State Overload Relay for Type S Starter - Trip Class 10/20, 1.5 tp 4.5A Overload Relay QO 9065ST220 Square D ST220 Overload Relay Replacement SSOLR for retrofit of Square D Type S Starter Solid State Overload Relay, 600 Vac maximum. Mounting: Replacement. Type Overload: SSOLR. Open type, trip Class 10/20. For 8536 Starter, NEMA size 2, full load current range 15-45A QO9065ST220 Overload Relay QO 9065TO1 Motor Logic Solid State Overload Relay for Type S Starter, Trip Class 10/20, 15-45A, 600V Max Square D TO1 Thermal Overload Relay Class 9065 Nema rated open type thermal overload relay. One-piece thermal unit and inverse time delay trip. 600vac maximum. Mounting: Separate. Type overload: Melting alloy. Nema size 2. Maximum full load current: 45 Amps. Single pole construction (one N.C. contact) QO9065TO1 Melting Alloy Overload Relay, Nema Size 2, For Separate Mounting, 45A, 600V max. Does Not Contain Clearance Items 102

105 Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters NEMA Type Accessories & Parts Push Button Kit QO 9999SA2 QO9999SA2 Square D 9999SA2 Push Button Kit Class 9999 Cover-Mounted Push button Kit. Nema 1 type enclosure. Start-Stop markings. Leads included Selector Switch QO 9999SC2 Push Button Kit - Start-Stop Square D 9999SC2 Selector Switch Class 9999 Cover-Mounted Selector Switch Kit. Nema 1 type enclosure. Markings: Hand-Off-Auto Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects QO9999SC2 Selector Switch - Hand-Off-Auto NEMA Type, 2-Pole 1-Phase Starters Size 0 Starter - Square D Size 0 Starter - 2 Pole, 1 Phase - Square D QO8536SBG1V02S QO8536SBO1V02S Size 1 Starter - Square D Starter, Size 0, Nema 1 Enc., 2-Pole, 1-Phase, 120V, Magnetic Full Voltage Starter - Melting Alloy Thermal Overload Relay, w/ Separate Control Circuit Starter, Size 0, Open Type, 2-Pole, 1-Phase, 120V, Magnetic Full Voltage Starter - Melting Alloy Thermal Overload Relay, w/ Separate Control Circuit Size 1 Starter - 2 Pole, 1 Phase - Square D QO8536SCG1V02S QO8536SCG2V02S Starter, Size 1, Nema 1 Enc., 2-Pole, 1-Phase, 120V, Magnetic Full Voltage Starter - Melting Alloy Thermal Overload Relay, w/ Separate Control Circuit Starter, Size 1, Nema 1 Enc., 2-Pole, 1-Phase, 120V, w/ Separate Control Circuit Does Not Contain Clearance Items 103

106 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters NEMA Type, 3-Pole 3-Phase Starters Size 0 0 Starter - Square D QO8536SAG12V02H QO8536SAO12V02H QO8536SAO12V02S Size 00 Starter - 3 Pole, 3 Phase - Square D Size 0 Starter - Square D Electrical - Distribution & Controls Starter, Size 00, Nema 1 Enc, 3-Pole, 3-Phase, 120V, Melting Alloy Thermal Overload Relay, w/ Separate Control Circuit Starter, Size 00, Open Type, 3-Pole, 3-Phase, 120V, Base Unit Trip Class 20, w/ Separate Control Circuit Starter, Size 00, Open Type, 3-Pole, 3-Phase, 120V, Melting Alloy Thermal Overload Relay, w/ Separate Control Circuit Size 0 Starter - 3 Pole, 3 Phase - Square D QO8536SBG2V02H3 QO8536SBG2V02S QO8536SBO2V02H3 QO8536SBO2V02S Size 1 Starter - Square D Starter, Size 0, Nema 1 Enc., 3-Pole, 3-Phase, 120V, Magnetic Full Voltage Starter w/ Separate Control Circuit Starter, Size 0, Nema 1 Enc., 3-Pole, 3-Phase, 120V, Magnetic Full Voltage Starter - Melting Alloy Thermal Overload Relay, w/ Separate Control Circuit Starter, Size 0, Open Type, 3-Pole, 3-Phase, 120V, Magnetic Full Voltage Starter - Overload Class 10/20 w/ Separate Control Circuit Starter, Size 0, Open Type, 3-Pole, 3-Phase, 120V, Magnetic Full Voltage Starter - Melting Alloy Thermal Overload Relay, w/ Separate Control Circuit Size 1 Starter - 3 Pole, 3 Phase - Square D QO8536SCG3V02H3 QO8536SCO3V02H3 Size 2 Starter - QO 8536SDG1V02H3 Starter, Size 1, Open Type, 3-Pole, 3-Phase, 120V, Magnetic Full Voltage Starter w/ Separate Control Circuit Starter, Size 1, Open Type, 3-Pole, 3-Phase, 120V, Magnetic Full Voltage Starter w/ Separate Control Circuit Square D SDG1V02H3 Type S Starter Non-reversing 3-Pole, 3-Phases, 600 Vac maximum. NEMA size 2. NEMA 1 painted sheet steel. Rated operation voltage: 600VAC. Control voltage: 120VAC 60Hz; 110VAC 50Hz. Rated current: 45A. Solid state motor Logic SSOLR, class 10/20. Separate control circuit. No control units. Rated power in HP: 25HP 575VAC, 25HP 460VAC, 15HP 230VAC, 10HP 200VAC. QO8536SDG1V02H3 Starter, Size 2, Nema 1 Enc., 3-Pole, 3-Phase, 120V, Overload Class 10/20 w/ Separate Control Circuit Does Not Contain Clearance Items 104

107 Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters NEMA Type, 3-Pole 3-Phase Starters Size 2 Starter - QO 8536SDO1V02H3 QO8536SDO1V02H3 Square D 8536SDO1V02H3 Starter Non-reversing full voltage starter. 3-pole, 3-phase, 600 Volt AC Max, 50/60Hz. Control Circuit Voltage 120V. Three thermal units required. Nema size 2. Continuous Current Rating: 45. Open style device, no enclosure. Separate control circuit. Thermal overload type: Solid state Motor Logic class 10/20 Size 3 Starter - QO 8536SEG1V02S Electrical - Distribution & Controls Starter, Size 2, Open Type, 3-Pole, 3-Phase, 120V, Base Unit Trip Class 10/20, w/ Separate Control Circuit Motor Controls - Contactors - Switches - Disconnects Square D SEG1V02S Full Voltage Starter Non-reversing, 3-pole, 3-phase, 600Vac maximum. Nema size: 3. Continuous current rating: 90A. Nema 1 surface mount enclosure. Overload type: Thermal - Melting Alloy. Control Voltage: 120V@60Hz - 110VAC@50Hz. Wired for separate control. Horsepower Rating (3-phase): 25HP@200VAC - 30HP@230VAC - 50HP@460/575VAC. Class S magnetic starters are used for full voltage starting and stopping of AC squirrel cage motors QO8536SEG1V02S Size 3 Starter - QO 8536SEO1V02S Starter, Size 3, Nema 1 Enc., 3-Pole, 3-Phase, 120V, w/ Separate Control Circuit Square D SEO1V02S Full Voltage Starter Non-reversing, 3-Pole, 3-Phase, 600Vac Maximum. Nema Size: 3. Continuous current rating: 90A. Open style device, no enclosure. Overload Type: Thermal - Melting Alloy. Control Voltage: 120V@60Hz - 110VAC@50Hz. Wired for separate control. Horsepower Rating (3-Phase): 25HP@200VAC - 30HP@230VAC - 50HP@460/575VAC. Class S magnetic starters are used for full voltage starting and stopping of AC squirrel cage motors QO8536SEO1V02S Size 4 Starter - QO 8536SFG1V02S Starter, Size 3, Open Type, 3-Pole, 3-Phase, 120V, w/ Separate Control Circuit Square D SFG1V02S Full Voltage Starter Non-reversing, 3-Pole, 3-Phase, 600Vac maximum. Nema size: 4. Continuous current rating: 135A. Nema 1 surface mount enclosure. Overload type: Thermal - Melting Alloy. Control Voltage: 120V@60Hz - 110VAC@50Hz. Wired for separate control. Horsepower Rating (3-phase): 40HP@200VAC - 50HP@230VAC - 100HP@460/575VAC. Class S magnetic starters are used for full voltage starting and stopping of AC squirrel cage motors QO8536SFG1V02S Starter, Size 4, Nema 1 Enc., 3-Pole, 3-Phase, 120V, w/ Separate Control Circuit Does Not Contain Clearance Items 105

108 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters NEMA Type, Thermal Unit Selection Square D - Type A Thermal Unit QOA11.0 QOA14.8 QOA2.15 QOA2.57 QOA21.3 QOA4.32 QOA6.20 QOA7.65 Square D - Thermal Units The following thermal units are in stock at Wolff Bros. Supply. Please see attached document for thermal unit selection Square D - Type B Thermal Unit Thermal Unit A Melting Alloy, Standard Trip Thermal Unit A Melting Alloy, Standard Trip Thermal Unit A Melting Alloy, Standard Trip Thermal Unit A Melting Alloy, Standard Trip Thermal Unit A Melting Alloy, Standard Trip Thermal Unit A Melting Alloy, Standard Trip Thermal Unit A Melting Alloy, Standard Trip Thermal Unit A Melting Alloy, Standard Trip Electrical - Distribution & Controls Square D - Thermal Units The following thermal units are in stock at Wolff Bros. Supply. Please see the Square D Thermal Unit Selection Chart at the end of the Electrical A Section of the printed catalog. If online, see attached document on any of these Thermal Unit items. QOB1.16 QOB1.30 QOB1.45 QOB1.67 QOB1.88 QOB10.2 QOB11.5 QOB12.8 QOB14.0 QOB15.5 QOB17.5 QOB19.5 QOB2.10 QOB2.40 QOB2.65 QOB22.0 QOB25.0 QOB28.0 QOB3.00 QOB3.30 QOB3.70 QOB32.0 QOB36.0 QOB4.15 QOB4.85 Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Does Not Contain Clearance Items 106

109 Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters NEMA Type, Thermal Unit Selection Square D - Type B Thermal Unit QOB40.0 QOB45.0 QOB5.50 QOB50.0 QOB56.0 QOB6.25 QOB6.90 QOB62.0 QOB7.70 QOB70.0 QOB79.0 QOB8.20 QOB88.0 QOB9.10 Square D - Type CC Thermal Unit Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Thermal Unit B Melting Alloy, Standard Trip Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects Square D - Thermal Units The following thermal units are in stock at Wolff Bros. Supply. Please see the Square D Thermal Unit Selection Chart at the end of the Electrical A Section of the printed catalog. If online, see attached document on any of these Thermal Unit items. QOCC103 QOCC112 QOCC132 QOCC156 QOCC167 QOCC196 QOCC50.1 QOCC59.4 QOCC64.3 QOCC68.5 QOCC74.6 QOCC81.5 QOCC87.7 QOCC94.0 Thermal Unit CC103 - Melting Alloy, Standard Trip Thermal Unit CC112 - Melting Alloy, Standard Trip Thermal Unit CC132 - Melting Alloy, Standard Trip Thermal Unit CC156 - Melting Alloy, Standard Trip Thermal Unit CC167 - Melting Alloy, Standard Trip Thermal Unit CC196 - Melting Alloy, Standard Trip Thermal Unit CC Melting Alloy, Standard Trip Thermal Unit CC Melting Alloy, Standard Trip Thermal Unit CC Melting Alloy, Standard Trip Thermal Unit CC Melting Alloy, Standard Trip Thermal Unit CC Melting Alloy, Standard Trip Thermal Unit CC Melting Alloy, Standard Trip Thermal Unit CC Melting Alloy, Standard Trip Thermal Unit CC Melting Alloy, Standard Trip Type DP Compact 2 Pole Contactors 20A DP Contactor QO 8910DP12V02 Square D DP12V02 DP Contactor Compact 2-Pole, 1-Phase, 600Vac maximum, non- reversing definite purpose contactor. Full load amps: 20. Resistive load amps: N.O. poles. Operating voltage: 120VAC@60Hz, 110VAC@50Hz. Horsepower Rating (1-Phase) 1HP@115VAC - 2HP@230VAC. Mounting type: Panel. Enclosure type: Open QO8910DP12V02 20A, 120V, Compact 2-Pole DP Contactor Does Not Contain Clearance Items 107

110 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters Type DP Compact 2 Pole Contactors 20A DP Contactor QO 8910DP12V14 QO8910DP12V14 Square D DP12V14 DP Contactor Compact 2-Pole, 1-Phase, 600Vac maximum, non-reversing definite purpose contactor. Full load amps: 20. Resistive load amps: N.O. Poles. Operating Voltage: 24VAC@50/60Hz. Horsepower Rating (1-Phase) 1HP@115VAC - 2HP@230VAC. Mounting type: Panel. Enclosure type: Open 20A, 24V, Compact 2-Pole DP Contactor 25A DP Contactor QO 8910DP22V02 Electrical - Distribution & Controls Square D DP22V02 DP Contactor Compact 2-Pole, 1-Phase, 600Vac maximum, non-reversing definite purpose contactor. Full load amps: 25. Resistive load amps: N.O. Poles. Operating voltage: 120VAC@60Hz - 110VAC@50Hz. Horsepower Rating (1-Phase): 2HP@115V - 3HP@230VAC. Mounting type: Panel. Enclosure type: Open QO8910DP22V02 25A, 120V, Compact 2-Pole DP Contactor 25A DP Contactor QO 8910DP22V09 Square D DP22V09 DP Contactor Compact 2-Pole, 1-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 25. Resistive load amps: N.O. poles. Operating voltage VAC@60Hz - 220VAC@50Hz. Horsepower Rating (1- Phase): 2HP@115VAC - 3HP@230VAC QO8910DP22V09 30A DP Contactor QO 8910DP32V02 25A, V, Compact 2-Pole DP Contactor Square D DP32V02 DP Contactor Compact 2-Pole, 1-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 30. Resistive load amps: N.O. Poles. Operating voltage: 120VAC@60Hz - 110VAC@50Hz. Horsepower rating (1- Phase): 2HP@115VAC - 5HP@230VAC QO8910DP32V02 30A, 120V, Compact 2-Pole DP Contactor Does Not Contain Clearance Items 108

111 Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters Type DPA 3 & 4 Pole Contactors 20A DPA Contactor QO 8910DPA13V02 QO8910DPA13V02 Square D DPA13V02 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 20. Resistance load amps: N.O. Poles. Operating voltage: 120VAC@60Hz - 110VAC@50Hz. Horsepower rating (1-Phase): 1HP@115VAC - 2HP@230VAC. Horsepower rating (3-Phase): 5HP@230VAC - 7.5HP@460/575VAC. Auxiliary contact modules snap on either side of the Type DPA contactors 20A, 120V, 3-Pole DPA Contactor 20A DPA Contactor QO 8910DPA13V09 Electrical - Distribution & Controls Square D DPA13V09 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 20. Resistance load amps: N.O. Poles. Operating voltage: 208/240VAC@60Hz - 220VAC@50Hz. Horsepower rating (1-Phase): 1HP@115VAC - 2HP@230VAC. Horsepower rating (3-Phase): 5HP@230VAC - 7.5HP@460/575VAC. Auxiliary contact modules snap on either side of the Type DPA contactors Motor Controls - Contactors - Switches - Disconnects QO8910DPA13V09 20A, 240V, 3-Pole DPA Contactor 25A DPA Contactor QO 8910DPA23V02 Square D 8910DPA23V02 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 25. Resistance load amps: N.O. Poles. Operating voltage: 120VAC@60Hz - 110VAC@50Hz. Horsepower rating (1-Phase): 2HP@115VAC - 3HP@230VAC. Horsepower rating (3-Phase): 7.5HP@230VAC - 10HP@460/575VAC. Auxiliary contact modules snap on either side of the Type DPA contactors QO8910DPA23V02 25A, 120V, 3-Pole DPA Contactor 30A DPA Contactor QO 8910DPA33V02 Square D 8910DPA33V02 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 30. Resistance load amps: N.O. Poles. Operating voltage: 120V@60Hz - 110VAC@50Hz. Horsepower rating (1-Phase): 2HP@115VAC - 5HP@230VAC. Horsepower rating (3-Phase): 10HP@230VAC - 15HP@460/575VAC. Auxiliary contact modules snap on either side of the Type DPA contactors QO8910DPA33V02 30A, 120V, 3-Pole DPA Contactor 30A DPA Contactor QO 8910DPA33V04 Square D 8910DPA33V04 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 30. Resistance load amps: N.O. Poles. Open enclosure, panel mount. Operating Voltage: Horsepower rating (1- Phase): 2HP@115VAC - 5HP@230VAC. Horsepower rating (3-Phase): 10HP@230VAC - 15HP@460/575VAC. Auxiliary contact modules snap on either side of the Type DPA contactors QO8910DPA33V04 30A, 277V, 3-Pole DPA Contactor Does Not Contain Clearance Items 109

112 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters Type DPA 3 & 4 Pole Contactors 30A DPA Contactor QO 8910DPA33V09 QO8910DPA33V09 Square D 8910DPA33V09 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 30. Resistance load amps: N.O. Poles. Open enclosure, panel mount. Operating voltage: 208/240VAC@60Hz - 220VAC@50Hz. Horsepower rating (1-Phase): 2HP@115VAC - 5HP@230VAC. Horsepower rating (3-Phase): 10HP@230AC - 15HP@460/575VAC. Auxiliary contact modules snap on either side of the Type DPA contactors 30A, V, 3-Pole DPA Contactor 30A DPA Contactor QO 8910DPA34V02 Electrical - Distribution & Controls Square D 8910DPA34V02 DPA Contactor 4-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Ampere Rating: 30A. Open enclosure, panel mount. Horsepower Rating (1-phase) 2HP@115VAC - 5HP@230VAC. Horsepower Rating (3-phase) 10HP@230VAC - 15HP@460/575VAC. Locked Rotor Amperes: 180A@230VAC - 150A@460VAC - 120A@575VAC. Auxiliary contact modules snap on either side of the DPA Contactors QO8910DPA34V02 30A, 120V, 4-Pole DPA Contactor 40A DPA Contactor QO 8910DPA43V02 Square D 8910DPA43V02 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 40. Resistance load amps: N.O. Poles. Open enclosure, panel mount. Operating voltage: 120VAC@60Hz - 110VAC@50Hz. Horsepower rating (1-Phase): 3HP@115VAC - 7.5HP@230VAC. Horsepower rating (3-Phase): 10HP@230VAC - 20HP@460/575VAC. Auxiliary contact modules snap on either side of the type DPA contactors QO8910DPA43V02 40A, 120V, 3-Pole DPA Contactor 40A DPA Contactor QO 8910DPA43V09 Square D 8910DPA43V09 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 40. Resistance load amps: N.O. Poles. Open enclosure, panel mount. Operating voltage: 208/240V@60Hz - 220VAC@50Hz. Horsepower rating (1-Phase): 3HP@115VAC - 7.5HP@230VAC. Horsepower rating (3-Phase): 10HP@230VAC - 20HP@460/575VAC. Auxiliary contact modules snap on either side of the type DPA contactors QO8910DPA43V09 40A, V, 3-Pole DPA Contactor 40A DPA Contactor QO 8910DPA43V14 Square D 8910DPA43V14 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 40. Resistance load amps: N.O. Poles. Open enclosure, panel mount. Operating voltage: 24VAC@50/60Hz. Horsepower rating (1- Phase): 3HP@115VAC - 7HP@230VAC. Horsepower rating (3-Phase): 10HP@230VAC - 20HP@460/575VAC. Auxiliary contact modules snap on either side of the type DPA contactors QO8910DPA43V14 40A, 24VAC, 3-Pole DPA Contactor Does Not Contain Clearance Items 110

113 Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters Type DPA 3 & 4 Pole Contactors 40A DPA Contactor QO 8910DPA44V09 QO8910DPA44V09 Square D 8910DPA44V09 DPA Contactor 4-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 40. Resistance load amps: N.O. Poles. Open enclosure, panel mount. Operating voltage: 208/240VAC@60Hz. Horsepower rating (1- Phase): 3HP@115VAC - 7.5HP@230VAC. Horsepower rating (3-Phase): 10HP@230VAC - 20HP@460/575VAC. Auxiliary contact modules snap on either side of the type DPA contactors 40A, V, 4-Pole DPA Contactor 50A DPA Contactor QO 8910DPA53V02 Electrical - Distribution & Controls Square D 8910DPA53V02 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 50. Resistance load amps: N.O. Poles. Enclosure: Open. Mounting: Panel. Operating voltage: 120VAC@60Hz - 110VAC@50Hz. Horsepower rating (1-Phase): 3HP@115VAC - 10HP@230VAC. Horsepower rating (3-Phase): 15HP@230VAC - 30HP@460/575VAC. Auxiliary contact modules snap on either side of the type DPA contactors Motor Controls - Contactors - Switches - Disconnects QO8910DPA53V02 50A, 120V, 3-Pole DPA Contactor 50A DPA Contactor QO 8910DPA53V09 Square D 8910DPA53V09 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 50. Resistance load amps: N.O. Poles. Enclosure: Open. Mounting: Panel. Operating voltage: 208/240VAC@60Hz - 220VAC@50Hz. Horsepower rating (1-Phase): 3HP@115VAC - 10HP@230VAC. Horsepower rating (3-Phase): 15HP@230VAC - 30HP@460/575VAC. Auxiliary contact modules snap on either side of the type DPA contactors QO8910DPA53V09 50A, V, 3-Pole DPA Contactor 60A DPA Contactor QO 8910DPA63V02 Square D 8910DPA63V02 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 60. Resistance load amps: N.O. Poles. Enclosure: Open. Mounting: Panel. Operating voltage: 120VAC@60Hz - 110VAC@50Hz. Horsepower rating (1-Phase): 5HP@115VAC - 10HP@230VAC. Horsepower rating (3-Phase): 25HP@230VAC - 30HP@460/575VAC. Auxiliary contact modules snap on either side of the type DPA contactors QO8910DPA63V02 60A, 120V, 3-Pole DPA Contactor 75A DPA Contactor OQ 8910DPA73V02 Square D 8910DPA73V02 DPA Contactor 3-Pole, 3-phase, 600VAC max. voltage, non-reversing definite purpose contactor. Ampere Rating: 75A. Enclosure: Open. Mounting: Panel. Operating Voltage: 120VAC@60Hz - 110VAC@50Hz. Horsepower rating (1-Phase): 5HP@115VAC - 15HP@230VAC. Horsepower rating (3-Phase): 25HP@230VAC - 40HP@460/575VAC QO8910DPA73V02 75A, 120V, 3-Pole DPA Contactor Does Not Contain Clearance Items 111

114 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters Type DPA 3 & 4 Pole Contactors 75A DPA Contactor QO 8910DPA73V14 QO8910DPA73V14 Square D 8910DPA73V14 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 75. Resistance load amps: N.O. Poles. Enclosure: Open. Mounting: Panel. Operating voltage: 24VAC@50/60Hz. Horsepower rating (3-phase): 25HP@230VAC - 40HP@460/575VAC. Horsepower rating (1-phase): 5HP@115VAC - 15HP@230VAC. Auxiliary contact modules snap on either side of the type DPA contactors 75A, 24VAC. 3-Pole DPA Contactor 90A DPA Contactor QO 8910DPA93V02 Electrical - Distribution & Controls Square D 8910DPA93V02 DPA Contactor 3-Pole, 3-Phase, 600VAC maximum voltage, non-reversing definite purpose contactor. Full load amps: 90. Resistance load amps: N.O. Poles. Enclosure: Open. Mounting: Panel. Operating Voltage: 120VAC@60Hz - 110VAC@50Hz. Horsepower rating (3-Phase): 30HP@230VAC - 50HP@460/575VAC. Horsepower rating (1-Phase): 7.5HP@115VAC - 20HP@230VAC. Auxiliary contact modules snap on either side of the type DPA contactors QO8910DPA93V02 90A, 120V, 3-Pole DPA Contactor Type DPS Definite Purpose Starters 50A 2-P DPS Starter QO8911DPSG52V09 Square D 8911DPSG52V09 Definite Purpose Starter 2-Pole, 1-Phase, 600VAC max. voltage, definite purpose starter. Ampere rating: 50A. Enclosure: NEMA 1 general purpose (indoor). Mounting: Surface. Operating voltage: 208/240VAC@60Hz - 220VAC@50Hz. Overload type: thermal - melting alloy. Control source: common contol circuit. Horsepower rating (1-phase): 3HP@115VAC - 10HP@230VAC QO8911DPSG52V09 50A, 240V, 2-Pole, Definite Purpose Starter, NEMA 1 Enclosure 50A 3-P DPS Starter QO8911DPSG53V06 Square D 8911DPSG53V06 Definite Purpose Starter 3-Pole, 3-phase, 600VAC max. voltage, definite purpose starter. Ampere rating: 50A. Enclosure: NEMA 1. Mounting: Surface. Operating voltage: 480VAC@60Hz - 440VAC@50Hz. Overload type: thermal, melting alloy. Control source: common control circuit. Horsepower rating (1-phase): 3HP@115VAC - 10HP@230VAC. Horsepower rating (3-phase): 15HP@230VAC - 30HP@460/575VAC QO8911DPSG53V06 50A, 480V, 3-Pole Definite Purpose Starter, NEMA 1 Enclosure Does Not Contain Clearance Items 112

115 Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters Type DPS Definite Purpose Starters 50A 3-P DPS Starter QO8911DPSG53V09 QO8911DPSG53V09 Square D 8911DPSG53V09 Definite Purpose Starter 3-Pole, 3-phase, 600VAC max. voltage, definite purpose starter. Ampere rating: 50A. Enclosure: NEMA 1 general purpose (indoor). Mounting: Surface. Operating voltage: 208/240VAC@60Hz - 220VAC@50Hz. Overload type: thermal - melting alloy. Control source: common contol circuit. Horsepower rating (1-phase): 3HP@115VAC - 10HP@230VAC. Horsepower rating (3-phase): 15HP@230VAC - 30HP@460/575VAC 50A, 240V, 3-Pole Definite Purpose Starter, NEMA 1 Enclosure 50A 3-P DPS Starter QO8911DPSO53V09 Electrical - Distribution & Controls Square D 8911DPSO53V09 Definite Purpose Starter 3-Pole, 3-phase, 600VAC max. voltage, definite purpose starter. Ampere rating: 50A. Enclosure: Open. Mounting: Surface. Operating voltage: 208/240VAC@60Hz - 220VAC@50Hz. Overload type: thermal - melting alloy. Control source: common contol circuit. Horsepower rating (1-phase): 3HP@115VAC - 10HP@230VAC. Horsepower rating (3-phase): 15HP@230VAC - 30HP@460/575VAC Motor Controls - Contactors - Switches - Disconnects QO8911DPSO53V09 50A, 240V, 3-Pole Definite Purpose Starter, Open NEMA TeSys Non-Reversing Contactors - QOT02 Square D TeSys N Non-Reversing Contactors NEMA magnetic non-reversing contactors are used to switch heating loads, capacitors, transformers and electric motors where overload protection is provided separately. 3-Pole Polyphase, 600 Vac Max. QOT02BN13G7 QOT02CN13G7 QOT02DN13G7 QOT02EN13G6 TeSys N Non-Reversing Contactor, NEMA Size 0, 18A Continuous Current Rating, 120V Coil Voltage, 3 Pole, 3 Phase TeSys N Non-Reversing Contactor, NEMA Size 1, 27A Continuous Current Rating, 120V Coil Voltage, 3 Pole, 3 Phase TeSys N Non-Reversing Contactor, NEMA Size 2, 45A Continuous Current Rating, 120V Coil Voltage, 3 Pole, 3 Phase TeSys N Non-Reversing Contactor, NEMA Size 3, 90A Continuous Current Rating, 120V Coil Voltage, 3 Pole, 3 Phase Square D - CAD TeSys D Control Relays Square D - CAD TeSys D IEC Style Relays IEC Type Instantaneous Industrial Control Relays. Terminal Type: Screw Clamp. Number of contacts: 5. Max. voltage rating: 600VAC. Ampere Rating: 10A. Mounting Type: Din Rail (35mm) Panel. QOCAD32T7 QOCAD32UD QOCAD50G7 TeSys D IEC Style Relay, Screw Clamp, 3-NO - 2-NC Contacts, Coil Voltage 480VAC TeSys D IEC Style Relay, Screw Clamp, 3-NO - 2-NC Contacts, Coil Voltage 250VAC TeSys D IEC Style Relay, Screw Clamp, 5-NO Contacts, Coil Voltage 120VAC Does Not Contain Clearance Items 113

116 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Contactors & Starters Square D - GV2AK00 TeSys Visible Isolation Block QOGV2AK00 Square D GV2AK00 TeSys Visible Isolation Block Front mounting, 3-pole visible isolation on incoming side of GV2P. This unit isolates the line side power from the starter, in order to remove line voltage entirely from the unit for testing, etc. It is called "visible" because it provides a visible means of verifying that the starter is isolated. Visible Isolation Block for the GV2P Manual Starter, 3-Pole Square D - Type DPA Replacement Coils Class 9998 Square D 9998DAx Replacement Coils Replacement Coils for Class 8910 Definite Purpose Contactors Electrical - Distribution & Controls QO9998DA1V A, 2 & 3 Poles, 277V, Replacement Coil For Class 8910 DPA Definite Purpose Contactors QO9998DA1V A, 2 & 3 Poles, 24V, Replacement Coil For Class 8910 DPA Definite Purpose Contactors QO9998DA2V A, 2 & 4 Poles, 110/120V, Replacement Coil For Class 8910 DPA Definite Purpose Contactors QO9998DA2V A, 2 & 3 Poles, 440/480V, Replacement Coil For Class 8910 DPA Definite Purpose Contactors QO9998DA2V A, 4-Pole, 208/240V, Replacement Coil For Class 8910 DPA Definite Purpose Contactors QO9998DA2V A, 4-Pole, 24V, Replacement Coil For Class 8910 DPA Definite Purpose Contactors QO9998DA3V A, 2 & 3 Poles, 110/120V, Replacement Coil for Class 8910 DPA Definite Purpose Contactors QO9998DA3V A, 2 & 3 Poles 208/240V, Replacement Coil for Class 8910 DPA Definite Purpose Contactors QO9998DA3V A, 2 & 3 Poles, 24V, Replacement Coil for Class 8910 DPA Definite Purpose Contactors Square D - IEC Contactors - Starters - Relays Square D - GV2 & GV3 Auxiliary Contact - GVAE11 Square D GVAE11 Auxiliary Contact Block Front mounted instantaneous auxiliary contact block provides auxiliary contacts on the front face of GV2 and GV3 motor circujit breakers. Contact Type: NO & NC. Maximum No. of Blocks: 1. Connection: Screw Clamp. QOGVAE11 Square D - GV2 TeSys Manual Starter Auxiliary Contact Block, 1 NO & 1 NC, for TeSys GV2 & GV3 Motor Circuit Bkrs. Square D GV2P14 Manual Starter & Protector TeSys non-reversing, 3-pole manual motor starter and protector. Thermal Trip Setting: 6.0A to 10.0A. Mounting: Panel. Terminal Type: Screw Clamp. Maximum Voltage Rating: 600VAC. Operator Type: Rotary Handle. Horsepower Rating (3- Phase): 2HP@200VAC - 3HP@230VAC - 5HP@460VAC - 7.5HP@575VAC. Horsepower Rating (1-Phase): 0.5HP@115VAC - 1.5HP@230VAC. QOGV2P A, 600V, 3-Pole, Manual Motor Starter & Protector w/ Rotary Handle Does Not Contain Clearance Items 114

117 Motor Controls - Contactors - Switches - Disconnects Square D - IEC Contactors - Starters - Relays Square D - GV2 TeSys Manual Starter QOGV2P A, 600V, 3-Pole Manual Motor Starter & Protector w/ Rotary Handle Square D - GV2ME Pushbutton Starters QOGV2MC01 QOGV2ME06 QOGV2ME07 QOGV2ME08 QOGV2ME10 QOGV2ME14 QOGV2ME16 QOGV2ME20 Square D - GV2ME Starters GV2 devices are 3-pole, horsepower-rated, manual starters and protectors. They include a manual disconnect, Class 10 ambient-compensated, bi-metallic thermal overload relay and an instantaneous magnetic trip mechanism in one compact unit. GV2M starters feature pushbutton control to indicate the On or Off state of the device. 35mm DIN rail mount or panel mount using a metal adapter plate. ACCESSORY Nema 1, IP41, Surface Mount Enclosure For GV2M, Maximum 1 Accessory on right and left Manual Starter and Protector 1-1.6A - 3-Pole A, 3-Pole, Pushbutton ON/OFF, Manual Starter 2.5-4A, 3-Pole, Pushbutton ON/OFF, Manual Starter and Protector 4-6.3A, 3-Pole, Pushbutton ON/OFF, Manual Starter and Protector 6-10A, 3-Pole, Pushbutton ON/OFF, Manual Starter and Protector 9-14A, 3-Pole Manual Starter and Protector 13-18A, 3-Pole Manual Starter and Protector Square D - GV3P TeSys Manual Starters Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects TeSys GV3P Manual Starters & Protectors 3-pole, horsepower rated, UL 508 listed manual starters with rotary handle. They include a manual disconnect, class 10 ambient-compensated thermal overload relay, and instantaneous, magnetic trip mechanism in one compact unit. Can be used alone for local manual control of a motor with individual full-load currents up to 220A. May also be used in group motor installations in accordance with NEC article QOGV3G66 QOGV3P13 QOGV3P18 QOGV3P25 QOGV3P40 ACCESSORY: Line Spacing Cover for TeSys GV3 Manual Starters 9-13A Manual Starter & Protector w/ Rotary Handle 12-18A Manual Starter & Protector w/ Rotary Handle 17-25A Manual Starter & Protector w/ Rotary Handle 30-40A 3P Manual Starter & Protector w/ Rotary Handle Square D - LAD Auxiliary Contact Blocks Square D - LAD Auxiliary Contact Blocks Standard, instantaneous auxiliary contact blocks for TeSys D-Line, K-Line and F-Line contactors. For use in normal operation environments. Maximum Voltage Rating: 600 Vac. Terminal Type: Screw Clamp. For low consumption coils, only one front-mounted two-contact block allowed (no side mounted contact blocks allowed). QOLAD8N11 QOLAD8N20 QOLADN11 QOLADN20 10A Auxiliary Contact Block, Clip-On Left Side Mount, 2 Contacts: 1-N.O. 1-N.C. 10A Auxiliary Contact Block, Clip-On Left Side Mount, 2 Contacts: 2-N.O. 10A Auxiliary Contact Block, Clip-On Front Mount, 2 Contacts: 1-N.O. 1-N.C. 10A Auxiliary Contact Block, Clip-On Front Mount, 2 Contacts: 2-N.O. Does Not Contain Clearance Items 115

118 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - IEC Contactors - Starters - Relays Square D - LC1D TeSys D-Line Contactors QOLC1D09G7 QOLC1D12G7 QOLC1D18G7 QOLC1D25G7 QOLC1D32G7 QOLC1D40G7 QOLC1D50G7 QOLC1D65G7 QOLC1D80G7 Square D - LC1D Series Contactors TeSys D-Line non-reversing contactors. 3-Phase, 120 VAC. 3-Pole (3NO). 1 N.O. and 1 N.C. Instantaneous Auxillary Contacts. Screw Terminal Connections. 35mm DIN Rail mount. UL listed, CSA Certified, IEC Rated, RoHS Compliant. 9A Contactor - 3-Pole - 1-N.O./1-N.C. Auxiliary Contacts, 120V 12A Contactor - 3-Pole - 1-N.O./1-N.C. Auxiliary Contacts, 120V 18A Contactor - 3-Pole - 1-N.O./1-N.C. Auxiliary Contacts, 120V 25A Contactor - 3-Pole - 1-N.O./1-N.C. Auxiliary Contacts, 120V 32A Contactor - 3-Pole - 1-N.O./1-N.C. Auxiliary Contacts, 120V 40A Contactor - 3-Pole - 1-N.O./1-N.C. Auxiliary Contacts, 120V 50A Contactor - 3-Pole - 1-N.O./1-N.C. Auxiliary Contacts, 120V 65A Contactor - 3-Pole - 1-N.O./1-N.C. Auxiliary Contacts, 120V 80A Contactor - 3-Pole - 1-N.O./1-N.C. Auxiliary Contacts, 120V Square D - LC1K0610F7 K-Line Mini Contactor Electrical - Distribution & Controls Square D - LC1K0610F7 Mini Contactor Miniature contactor (TeSys K) non-reversing. 3-Pole. 6A inductive maximum current. 15A resistive maximum current. Coil Voltage: 110VAC, 50/60Hz. Horsepower Rating 1-Phase: 0.5HP@115VAC - 1.5HP@230VAC. Horsepower Rating 3- Phase: 1.5HP@200/230VAC - 3HP@460/575VAC. Screw clamp termination. Auxiliary contacts: 1 N.O. Panel Mount. QOLC1K0610F7 6A TeSys K Mini Contactor - 110VAC, 1 N.O. Auxillary Contact - Screw Clamp Square D - LRD TeSys D-Line Overload Relays Square D - LRD Overload Relays TeSys C Class 10 thermal overload relays with single phase sensitivity. 3-Pole. Compensated relays with manual or automatic reset with relay trip indicator. Connection: screw clamp terminals. Designed for direct mounting to D-line contactors. To mount these overloads separately, you need mount kits which are purchased separately. QOLAD7B106 QOLRD05 QOLRD06 QOLRD07 QOLRD08 QOLRD10 QOLRD12 QOLRD14 QOLRD16 QOLRD21 QOLRD22 QOLRD32 QOLRD3322 ACCESSORY: Terminal Block Mounting Kit, Fingersafe, Mount to 35mm DIN Rail or Panel w/ Screws, For Use w/ LRD01-35, Up To 38A Class 10 Overload Relay with 1-Phase Sensitivity A, For Direct Mounting to LC1D09-D32 Class 10 Overload Relay with 1-Phase Sensitivity A, For Direct Mounting to LC1D09-D32 Class 10 Overload Relay with 1-Phase Sensitivity A, For Direct mounting to LC1D09-D32 Class 10 Overload Relay with 1-Phase Sensitivity 2.5-4A, For Direct Mounting to LC1D09-D32 Class 10 Overload Relay with 1-Phase Sensitivity 4-6A, For Direct Mounting to LC1D09-D32 Class 10 Overload Relay with 1-Phase Sensitivity 5.5-8A, For Direct Mounting to LC1D09-D32 Class 10 Overload Relay with 1-Phase Sensitivity 7-10A, For Direct Mounting to LC1D09-D32 Class 10 Overload Relay with 1-Phase Sensitivity 9-13A, For Direct Mounting to LC1D12-D32 Class 10 Overload Relay with 1-Phase Sensitivity 12-18A, For Direct Mounting to LC1D18-D32 Class 10 Overload Relay with 1-Phase Sensitivity 16-24A, For Direct Mounting to LC1D25-D32 Class 10 Overload Relay with 1-Phase Sensitivity 23-32A, For Direct Mounting to LC1D25-D32 Class 10 Overload Relay with 1-Phase Sensitivity 17-25A, For Direct Mounting to LC1D40-D80 Does Not Contain Clearance Items 116

119 Motor Controls - Contactors - Switches - Disconnects Square D - IEC Contactors - Starters - Relays Square D - LRD TeSys D-Line Overload Relays QOLRD3353 QOLRD3355 QOLRD3357 QOLRD3359 QOLRD3361 QOLRD3363 QOLRD35 Square D - LXD1 Contactor Coils Class 10 Overload Relay with 1-Phase Sensitivity 23-32A, For Direct Mounting to LC1D40-D80 Class 10 Overload Relay with 1-Phase Sensitivity 30-40A For Direct Mounting to LC1D40-D80 Class 10 Overload Relay with 1-Phase Sensitivity 37-50A, For Direct Mounting to LC1D50-D80 Class 10 Overload Relay with 1-Phase Sensitivity 48-65A, For Direct Mounting to LC1D50-D80 Class 10 Overload Relay with 1-Phase Sensitivity 55-70A, For Direct Mounting to LC1D65-D80 Class 10 Overload Relay with 1-Phase Sensitivity 63-80A, For Direct Mounting to LC1D65-D80 Class 10 Overload Relay with 1-Phase Sensitivity 30-38A, For Direct Mounting to LC1D32 Electrical - Distribution & Controls Square D - LXD1 Contactor Coils Replacement AC Coils for 3-Pole LC1D09-D32 (TeSys) D-Line K-Line and F-Line Contactors. 50/60Hz. Motor Controls - Contactors - Switches - Disconnects QOLXD1B7 QOLXD1G7 QOLXD1T7 QOLXD1U7 Replacement Coil, 24V AC, for TeSys D09-D32 Replacement Coil, 120V AC, for TeSys D09-D32 Replacement Coil, 480V AC, for TeSys D09-D32 Replacement Coil, 230/240V AC, for TeSys D09-D32 Square D - TeSys U Line Motor Starters Square D U-Line Motor Starters The U-Line self-protected motor starter consists of one power base and one control unit as a minimum. Each power base with control circuit screw clamp terminals includes one N.O. and one N.C. auxiliary contact to indicate the open or closed position of the power contacts. The control units contain solid state overload relay and control power source for the U-line motor starters. Standard 3-phase Class 10 Trip. Voltage Code: FU V AC or DC. QOLUB12 U-Line Power Base, 12A, Self Protected - Needs LUCA Control Unit to Complete U-Line Motor QOLUCA05FU 1.25 to 5A, 120V Control Unit, Standard 3-Phase Class 10 Trip, Needs LUB Power Base to Complete QOLUCA12FU 3 to 12A, 120V Control Unit, Standard 3-Phase Class 10 Trip, Needs LUB Power Base to Complete Square D - Lighting Contactors Square D - Type L Multipole QO 8903LGxxV02 Square D 8903LGxxV02 Multipole Lighting Contactor Type L Electrically Held Lighting Contactor. 600Vac, 30A fluorescent lighting rating, 20A tungsten lighting rating. Electrically held operation. NEMA 1 general purpose enclosure. Mounting type: Surface. Coil voltage: 120V/60Hz, 110V/50 Hz. Numerous number of poles available. QO8903LG20V02 QO8903LG30V02 QO8903LG40V02 QO8903LG60V02 30A, 2-Pole, NEMA 1 Electrically Held Lighting Contactor, 120V@60Hz - 110V@50Hz 30A, 3-Pole, NEMA 1 Electrically Held Lighting Contactor, 120V@60Hz - 110V@50Hz 30A, 4-Pole, NEMA 1 Electrically Held Lighting Contactor - 120V@60Hz - 110V@50Hz 30A, 6-Pole, NEMA 1 Electrically Held Lighting Contactor - 120V@60Hz - 110V@50Hz Does Not Contain Clearance Items 117

120 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Lighting Contactors Square D - Type L Multipole QO 8903LGxxV02 QO8903LG80V02 30A, 8-Pole, NEMA 1 Electrically Held Lighting Contactor - 120V@60Hz - 110V@50Hz Square D - Type L Open Multipole QO 8903LO40V02 QO8903LO40V02 Square D 8903LO40V02 Multipole Lighting Contactor Type L, 4-Pole, Open Lighting Contactor. 600Vac, 30A fluorescent lighting rating, 20A tungsten lighting rating. Electrically held operation. Open - no enclosure. Mounting type: Surface. Coil voltage: 120V/60Hz, 110V/50Hz. 30A, 4-Pole, Open Type Electrically Held Lighting Contactor - 120V@60Hz - 110V@50Hz Square D - Type S Multipole QO 8903SPG2V02 Electrical - Distribution & Controls Square D 8903SPG2V02 Multipole Lighting Contactor Type S, 60Amp, 3-Pole, Lighting Contactor. 600Vac maximum voltage. Electrically held operation. NEMA 1 general purpose enclosure. Mounting type: Surface. Terminal type: Lugs. Coil voltage: 120V/60Hz, 110V/50Hz. QO8903SPG2V02 Square D - Manual Starters Type F Fractional Horsepower 60A, 3-Pole, NEMA 1 Type S Electrically Held Lighting Contactor - 120V@60Hz - 110V@50Hz 1-Pole Toggle Starter Open QO 2510FO1 Square D 2510FO1 Manual Toggle Starter Type F, fractional horsepower, non-reversing, 1-Pole, 1-Phase, manual starter. Ampere rating: 16A. Open, no enclosure. Operator type: toggle. Overload type: Thermal - Melting Alloy. Horsepower rating (1-Phase): 1HP@115/230/277VAC. Maximum voltage rating: 600VAC/250VDC. Provides overload protection as well as manual ON/OFF control for small motors. Dimensions: 4.13"H x 1.69"W x 2.22"D QO2510FO1 1-Pole Toggle Starter QO 2510FG1 Toggle Operated Manual Starter, Open, 16A, 1-Pole Square D 2510FG1 Toggle Manual Starter Type F, fractional horsepower, non-reversing, 1-Pole, 1-Phase, manual starter. Ampere rating: 16A. Enclosure: NEMA 1, single unit metal box. Operator type: Toggle. Overload type: Thermal - melting alloy. Horsepower rating (1-Phase): 1HP@115/230/277VAC. Provides overload protection as well as manual ON/OFF control. Mounting: Surface. Dimensions: 4.25"H x 2.44"W x 2.75"D QO2510FG1 Toggle Operated Manual Starter, NEMA 1 Enc., 16A, 1-Pole Does Not Contain Clearance Items 118

121 Motor Controls - Contactors - Switches - Disconnects Square D - Manual Starters Type F Fractional Horsepower 1-Pole Toggle Starter w/pilot QO 2510FG1P QO2510FG1P Square D 2510FG1P Manual Toggle Starter Type F, fractional horsepower, non-reversing, 1-Pole, 1-Phase, manual starter with red pilot light. Ampere rating: 16A. Enclosure: NEMA 1, single unit metal box. Operator type: Toggle. Overload type: Thermal - melting alloy. Horsepower rating (1-Phase): 1HP@115/230/277VAC. Provides overload protection as well as manual ON/OFF control. Mounting: Surface. Dimensions: 4.25"H x 2.44"W x 2.75"D 2-Pole Toggle Starter QO 2510FG2 Toggle Operated Manual Starter, NEMA 1 Enc., 16A, 1-Pole, w/ Red Pilot Light Electrical - Distribution & Controls Square D 2510FG2 Manual Toggle Starter Type F, fractional horsepower, non-reversing, 2-Pole, 2-Phase, manual starter. Ampere rating: 16A. Enclosure: NEMA 1, single unit metal box. Operator type: Toggle. Overload type: Thermal - Melting Alloy. Horswpower rating (1-Phase): 1HP@115/230/277VAC HP@115/230VDC. Maximum voltage rating: 600VAC/250VDC. Provides overload protection as well as manual ON/OFF control for small motors. Mounting: Surface. Dimensions: 4.25"H x 2.44"W x 2.75"D Motor Controls - Contactors - Switches - Disconnects QO2510FG2 Accessory Handle Guard QO 2510FL1 Toggle Operated Manual Starter, NEMA 1 Enc, 16A, 2-Pole Square D 2510FL1 Handle Guard Kit Handle Guard Kit with Padlock Provision (standard on Type K devices) for devices 2510F, 2510K QO2510FL1 Type K Non-Reversing Class 2510 Types F & K Handle Guard Kit w/ Paddlock Provision 2-Pole Toggle Starter Open QO 2510KO1 Square D 2510KO1 Manual Switch Type K, non-reversing, 2-Pole, 1-Phase, manual switch. Ampere Rating: 30A. Enclosure: Open. Operator type: Toggle. Short Circuit Current Rating: 5000 AIR. Maximum voltage rating: 600VAC/230VDC. Provides manual ON/OFF control of single or three phase AC motors where overload protection is not required or provided separately. Horsepower Rating (1- Phase): 2HP@115/230VAC - 3HP@460/575VAC. Dimensions: 4.13"H x 1.69"W x 2.22"D QO2510KO1 Toggle Operated Manual Starter Switch, Open, 30A, 2-Pole Does Not Contain Clearance Items 119

122 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Manual Starters Type K Non-Reversing 2-Pole Toggle Starter QO 2510KG1 QO2510KG1 Square D 2510KG1 Manual Switch Type K, non-reversing, 2-Pole, 1-Phase, manual switch. Ampere Rating: 30A. Enclosure: NEMA 1, single unit metal box. Operator type: Toggle. Mounting type: Surface. Short circuit current rating: 5000 AIR. Maximum voltage rating: 600VAC/230VDC. Provides manual ON/OFF control of single or three phase AC motors where overload protection is not required or provided separately. Dimensions: 4.25"H x 2.44"W x 2.88"D Toggle Operated Manual Starter Switch, NEMA 1 Enc., 30A, 2-Pole 3-Pole Toggle Starter Open QO 2510KO2 Electrical - Distribution & Controls Square D 2510KO2 Manual Switch Type K, non-reversing, 3-Pole, 3-Phase, manual switch. Ampere rating: 30A. Enclosure: Open. Operator type: Toggle. Short Circuit Current Rating: 5000 AIR. Maximum voltage rating: 600VAC/230VDC. Provides manual ON/OFF control of single or three phase AC motors where overload protection is not required or provided separately. Horsepower Rating (3- phase): 2HP@115VAC - 7.5HP@230VAC - 10HP@460/575VAC. Dimension: 4.13"H x 1.69"W x 2.22"D QO2510KO2 3-Pole Toggle Starter QO 2510KG2 Toggle Operated Manual Starter Switch, Open, 30A, 3-Pole Square D 2510KG2 Manual Switch Type K, non-reversing, 3-Pole, 3-Phase, manual switch. Ampere Rating: 30A. Enclosure: NEMA 1, single unit metal box. Operator type: Toggle. Mounting type: Surface. Short circuit current rating: 5000 AIR. Maximum voltage rating: 600VAC/230VDC. Provides manual ON/OFF control of single or three phase AC motors where overload protection is not required or provided separately. Horsepower Rating (3-Phase): 2HP@115VAC - 7.5HP@230VAC - 10HP@460/575VAC. Dimensions: 4.25"H x 2.44"W x 2.88"D QO2510KG2 Type M Integral Horsepower M-0 Manual Starter QO 2510MBG2 Toggle Operated Manual Starter Switch, NEMA 1 Enc., 30A, 3-Pole Square D 2510MBG2 Manual Starter Type M integral horsepower, non-reversing, 3-Pole, 3-Phase manual starter. Ampere rating: 18A. NEMA size: M-0. Enclosure Rating: NEMA 1 general purpose indoor. Mounting: Surface. Overload type: Thermal - melting alloy. Operator type: Pushbutton. Horsepower rating (3-Phase): 3HP@200/230VAC, 5HP@380/575VAC QO2510MBG2 Manual Starter Size M-0, NEMA 1 Enc., 18A, 3-Pole, 3-Phase, Integral Horsepower Non-Reversing Does Not Contain Clearance Items 120

123 Motor Controls - Contactors - Switches - Disconnects Square D - Manual Starters Type M Integral Horsepower M-1 Manual Starter QO 2510MCG3 QO2510MCG3 Square D 2510MCG3 Manual Starter Type M integral horsepower, non-reversing, 3-Pole, 3-Phase manual starter. Ampere rating: 27A. NEMA size: M-1. Enclosure rating: NEMA 1 general purpose indoor. Mounting: Surface. Overload type: Thermal - melting alloy. Operator type: Pushbutton. Horsepower Rating (3-Phase): 7.5HP@200/230VAC, 10HP@ VAC Manual Starter Size M-1, NEMA 1 Enc., 27A, 3-Pole, 3-Phase, Integral Horsepower Non-Reversing Square D - Safety Switches & Handle Mechanisms Air Conditioning Disconnects Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects AC Disconnect - QO 200TR Air Conditioner Disconnect Switch - QO200TR Non Fusible Molded Case AC Disconnect Switch for use with air conditioner. Ampere Rating: 60A. Voltage Rating: 240VAC. Enclosure: NEMA 3R Metallic - Rain and ice proof. Mounting: Panel/Surface. No. of Poles: 2-Pole. Does not contain overcurrent protection. Suitable for use on systems with up to 10kA available fault current at 240VAC (max) when protected by a fuse or circuit breaker rated 60A or less QO200TR 60A 2-Pole, Air Conditioning Disconnect Switch, Non-Fusible, NEMA 3R - Non-Fusible - 6.5"H x 4.63"W x 3.88"D Double Throw Non-Fusible - Square D Double Throw Non-Fusible - QO DTU224NRB 200A Double Throw Safety Switch - QODTU224NRB Safety switch, 200A, non-fusible, 240VAC, 10kA, 2-Pole. Enclosure: NEMA 3R, Rainproof and sleet/ice proof (indoor/outdoor). Factory installed neutral. Mounting type: Surface. Wire size: #6 to 300 AWG/kcmil(Al/Cu). UL listed QODTU224NRB General Duty - Fusible 240V Nema 1, 2-Pole - QO D2 - N 200A NEMA 3R, 2-Pole, 240Vac, Double Throw Safety Switch 2-Pole Fusible Safety Switches - QOD2x N General Duty indoor, up to 100 ka short circuit current rating depending on fuse type. Nema 1 enclosure. Disconnect type: fusible. 2 Poles and a factory installed neutral. UL listed QOD211N QOD221N QOD222N QOD223N 30A Disconnect Switch, Fusible, Plug, 2-Pole, NEMA 1, w/ Neutral, 120/240Vac "H x 6.75"W x 3.63"D 30A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 2-Pole, NEMA 1, w/ Neutral, 240Vac "H x 6.75"W x 3.63"D 60A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 2-Pole, NEMA 1, w/ Neutral, 240Vac "H x 6.50"W x 4.88"D 100A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 2-Pole, NEMA 1, w/ Neutral, 240Vac "H x 8.5"W x 6.5"D Does Not Contain Clearance Items 121

124 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Safety Switches & Handle Mechanisms General Duty - Fusible 240V Nema 1, 2-Pole - QO D2 - N QOD224N Nema 1, 3-Pole - QO D3 - N Electrical - Distribution & Controls 200A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 2-Pole, NEMA 1, w/ Neutral, 240Vac - 29"H x 17.25"W x 8.25"D 3-Pole Fusible Safety Switches - QOD3x N General Duty indoor, up to 100 ka short circuit current rating depending on fuse type. Nema 1 enclosure. Disconnect type: fusible. 4 Wire (3 Blades and fuseholders, 1 neutral). 240 Vac Max voltage QOD321N QOD322N QOD323N QOD324N QOD325N Nema 3R, 2-Pole - QO D2 - NRB 30A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 3-Pole, NEMA 1, w/ Neutral, 240Vac "H x 6.75"W x 3.63"D 60A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 3-Pole, NEMA 1, w/ Neutral, 240Vac "H x 6.75"W x 4.88"D 100A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 3-Pole, NEMA 1, w/ Neutral, 240Vac "H x 8.5"W x 6.5"D 200A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 3-Pole, NEMA 1, w/ Neutral, 240Vac - 29"H x 17.25"W x 8.25"D 400A Disconnect Switch, Fusible, Cartridge (Class H, K, J or R), 3-Pole, NEMA 1, w/ Neutral, 240Vac "H x 24"W x 8.88"D 2-Pole Fusible Safety Switches - QOD2x NRB General Duty Safety Switches, up to 100 ka short circuit rating depending on fuse type. Nema 3R enclosure. Disconnect type: fusible. 3 Wire (2 Blades and Fuseholders, 1 Neutral). 240 Vac Max voltage QOD221NRB QOD222NRB QOD223NRB QOD224NRB Nema 3R, 3-Pole - QO D3 - NR & NRB 30A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 2-Pole, NEMA 3R, w/ Neutral, 240Vac, w/bolt-on Closing Cap "H x 7.25"W x 3.75"D 60A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 2-Pole, NEMA 3R, w/ Neutral, 240Vac, w/bolt-on Closing Cap "H x 6.63"W x 4.83"D 100A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 2-Pole, NEMA 3R, w/ Neutral, 240Vac, w/bolt-on Closing Cap "H x 8.5"W x 6.5"D 200A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 2-Pole, NEMA 3R, w/ Neutral, 240Vac, w/bolt-on Closing Cap "H x 17.25"W x 8.25"D 3-Pole Fusible Safety Switches - QOD3x NR or NRB General Duty Safety Switches, up to 100 ka short circuit rating depending on fuse type. Nema 3R enclosure. Disconnect type: Fusible. 4 Wire (3 Blades and Fuseholders, 1 Neutral). 240 Vac Max. voltage. NEMA 3R rainproof enclosures with CAT. No. ending in RB have a bolt-on closing cap factory-installed QOD321NRB QOD322NRB QOD323NRB 30A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 3-Pole, NEMA 3R, w/ Neutral, 240Vac, w/bolt-on Closing Cap "H x 7.25"W x 3.75"D 60A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 3-Pole, NEMA 3R, w/ Neutral, 240Vac, w/bolt-on Closing Cap "H x 6.75"W x 4.88"D 100A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 3-Pole, NEMA 3R, w/ Neutral, 240Vac, w/bolt-on Closing Cap "H x 8.5"W x 6.5"D Does Not Contain Clearance Items 122

125 Motor Controls - Contactors - Switches - Disconnects Square D - Safety Switches & Handle Mechanisms General Duty - Fusible 240V Nema 3R, 3-Pole - QO D3 - NR & NRB QOD324NRB QOD325NR General Duty - Non-Fusible 240V NEMA 1, 3-Pole - QO DU32 Electrical - Distribution & Controls 200A Disconnect Switch, Fusible, Cartridge (Class H, K or R), 3-Pole, NEMA 3R, w/ Neutral, 240Vac, w/bolt-on Closing Cap "H x 17.25"W x 8.25"D 400A Disconnect Switch, Fusible, Cartridge (Class H, K, J or R), 3-Pole, NEMA 3R, w/neutral, 240Vac "H x 21.38"W x 10.13"D 3-Pole Non-Fusible Safety Switches - QODU32x General Duty Safety Swiches for up to 100 ka short circuit rating. Nema 1, non-fusible. 3 Wire (3 Blades). 240 Vac Maximum. UL listed Motor Controls - Contactors - Switches - Disconnects QODU321 QODU322 QODU323 QODU324 NEMA 3R, 2-Pole - QO DU221RB 30A Disconnect Switch, 3-Pole 240Vac Max, NEMA 1 Non-Fusible "H x 6.75"W x 3.63"D 60A Disconnect Switch, 3-Pole 240Vac Max, NEMA 1 Non-Fusible "H x 6.75"W x 3.63"D 100A Disconnect Switch, 3-Pole 240Vac Max, NEMA 1 Non-Fusible (when neutral is required, order part # QOSN0610) "H x 8.5"W x 6.5"D 200A Disconnect Switch, 3-Pole 240Vac Max, NEMA 1 Non-Fusible (when neutral is required, order part # QOSN20A) - 29"H x 17.25"W x 8.25"D 2-Pole Non-Fusible Safety Switch - QODU221RB General Duty Safety Switch for up to 100,000A short circuit rating. Nema 3R. Not Fusible. 2 Wire (2 Blades). 240 Vac Max. UL Listed QODU221RB NEMA 3R, 3-Pole - DU32-RB 30A Disconnect Switch, 2-Pole 240Vac Max, NEMA 3R Non-Fusible "H x 7.25"W x 3.75"D 3-Pole Non-Fusible Safety Switch - QODU32x RB General Duty Safety Switches for up to 100,000A short circuit rating. Nema 3R Rainproof. Not Fusible. 3 Wire (3 Blades). 240VAC Max. voltage rating QODU321RB QODU322RB QODU323RB QODU324RB 30A Disconect Switch, 3-Pole 240Vac Max, NEMA 3R Not Fusible "H x 7.25"W x 3.75"D 60A Disconnect Switch, 3-Pole 240Vac Max, NEMA 3R Not Fusible "H x 7.25"W x 3.75"D 100A Disconnect Switch, 3-Pole 240Vac Max, NEMA 3R Not Fusible (when neutral is required, order part # QOSN0610) "H x 8.5"W x 6.5"D 200A Disconnect Switch, 3-Pole 240Vac Max, NEMA 3R Not Fusible (when neutral is required, order part # QOSN20A) "H x 17.25"W x 8.25"D Does Not Contain Clearance Items 123

126 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Safety Switches & Handle Mechanisms Heavy Duty - Fusible 240V NEMA 1, 3-Pole - QO H32-N QOH321N QOH322N QOH323N 3-Pole Heavy Duty Safety Switches - QOH32x N 240 Volt single throw fusible heavy duty safety switches. Features quick-make, quick break operating mechanism. Nema 1 enclosure. 4-Wire (3 blades and fuseholders, 1 neutral). Short circuit current rating: 10kA (Class H or K) - 200kA (Class R, J or L) NEMA 3R, 3-Pole - QO H321NRB Electrical - Distribution & Controls 30A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 1, w/ Neutral, 240VAC/250VDC "H x 6.5"W x 4.88"D 60A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 1, w/ Neutral, 240VAC/250VDC "H x 6.5"W x 4.88"D 100A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 1, w/ Neutral, 240VAC/250VDC "H x 8.5"W x 6.38"D 3-Pole Heavy Duty Safety Switch - QOH321NRB 240 Volt single throw fusible heavy duty safety switch. Features quick-make, quick break operating mechanism. NEMA 3R Rainproof enclosure. 4-Wire (3 blades and fuseholders, 1 neutral). Short circuit current rating: 10kA (Class H or K) - 200kA (Class R, J or L). NEMA 3R rainproof enclosures with CAT. No. ending in RB have a bolt-on closing cap factory-installed QOH321NRB Heavy Duty - Fusible 600V NEMA 1, 3-Pole - QO H36 30A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 3R, w/ Neutral, 240Vac/250VDC, w/bolt-on Closing Cap "H x 6.63"W x 4.88"D 3-Pole Heavy Duty Safety Switch - QOH36x 600V single throw fusible heavy duty disconnect / safety switch. NEMA 1 enclosure rating. 3 Wire (3 blades and fuseholders). 600 Vac, 600 Vdc. Short circuit current rating: 10kA (Class H or K) - 200kA (Class R, J or L). QOH361 QOH362 QOH363 QOH364 QOH365 QOH366 30A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 1, 600V "H x 6.5"W x 4.88"D 60A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 1, 600V "H x 9"W x 6.38"D 100A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 1, 600V "H x 8.5"W x 6.38"D 200A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 1, 600V - 29"H x 17.13"W x 8.5"D 400A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 1, 600V "H x 27.63"W x 10.13"D 600A Heavy Duty Disconnect Switch, Single Throw Fusible, 3-Pole, NEMA 1, 600V Does Not Contain Clearance Items 124

127 Motor Controls - Contactors - Switches - Disconnects Square D - Safety Switches & Handle Mechanisms Heavy Duty - Fusible 600V NEMA 12 w/o Knockouts - QO H361AWK QOH361AWK 3-Pole Heavy Duty Safety Switch - QOH361AWK 600 Volts, single throw fusible, heavy duty safety switch. Nema 12, without knockouts. Also suitable for Nema 3R application by removing drain screw from bottom endwall. 3 Wire (3 Blades and Fuseholders). 600Vac, 600Vdc. (On 3- Pole devices, use two outside poles for switching DC). Short circuit current rating: 10kA (Class H or K) - 200kA (Class R, J or L) NEMA 3R, 3-Pole - QO H36-RB Electrical - Distribution & Controls 30A Heavy Duty Disconnect Switch, Single Throw Fusible, NEMA 12 w/o Knockouts, 3-Pole, 600V "H x 6.63"W x 4.96"D Motor Controls - Contactors - Switches - Disconnects 3-Pole Heavy Duty Safety Switches w/ Bolt-On Hubs - QOH36x RB 600 Volts, single throw fusible, heavy duty disconnect / safety switches. NEMA 3R enclosure rating. 3 Wire (3 blades and fuseholders) 600 Vac, 600 Vdc. Short circuit rating: 10kA (Class H or K) - 200kA (Class R, J or L) NEMA 3R rainproof enclosures with Cat. No. ending in RB have a bolt-on closing cap. On 3-pole devices, use two outside poles for switching DC QOH361RB QOH362RB QOH363RB QOH364RB Heavy Duty - Non-Fusible 600V NEMA 1, 3-Pole - QO HU36 30A Heavy Duty Disconnect Switch, Single Throw Fusible, NEMA 3R, 3-Pole, 600V, w/ Bolt-on Closing Cap "H x 6.63"W x 4.88"D 60A Heavy Duty Disconnect Switch, Single Throw Fusible, NEMA 3R, 3-Pole, 600V, w/ Bolt-on Closing Cap "H x 9"W x 6.38"D 100A Heavy Duty Disconnect Switch, Single Throw, Fusible, NEMA 3R, 3-Pole, 600V w/ Bolt-on Closing Cap "H x 8.5"W x 6.38"D 200A Heavy Duty Disconnect Switch, Single Throw, Fusible, NEMA 3R, 3-Pole, 600V w/ Bolt-on Closing Cap "H x 17.25"W x 8.5"D 3-Pole Non-Fusible Heavy Duty Safety Switches - QOHU36x 600 Volts, single throw, non-fusible, heavy duty disconnect / safety switches. NEMA 1 indoor enclosure rating. 3 Wire (3 Blades). 600 Vac, 600 Vdc. Short Circuit Current Rating: 200kA (max) QOHU361 QOHU362 QOHU363 QOHU364 30A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 1, 3-Pole, 600V "H x 6.5"W x 4.88"D 60A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 1, 3-Pole, 600V "H x 9"W x 6.38"D 100A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 1, 3-Pole, 600V "H x 8.5"W x 6.38"D 200A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 1, 3-Pole, 600V - 29"H x 17.13"W x 8.25"D NEMA 12 w/o Knockouts - QOHU361AWK 3-Pole Heavy Duty Safety Switch - QOHU361AWK 600 Volts, single throw, non-fusible, heavy duty safety switch. NEMA 12, without knockouts. Also suitable for NEMA 3R application by removing drain screw from bottom endwall. 3-wire (3 Blades). 600Vac, 600Vdc. Short Circuit Current Rating: 200kA (max) QOHU361AWK 30A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 12 Without Knockouts, 3-Pole, 600V "H x 6.63"W x 4.96"D Does Not Contain Clearance Items 125

128 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Safety Switches & Handle Mechanisms Heavy Duty - Non-Fusible 600V NEMA 3R, 3-Pole - QO HU36-R & RB QOHU361RB QOHU362RB QOHU363RB QOHU364RB QOHU365R 3-Pole Heavy Duty Non-Fusible Safety Switches - QOHU36x R & RB 600 Volts, single throw, non-fusible, heavy duty disconnect / safety switches. NEMA 3R enclosure rating. 3 Wire (3 Blades). 600 Vac, 600 Vdc. Short Circuit Current Ratings: 200kA (max). NEMA 3R rainproof enclosures ending in RB have a bolt-on closing cap 30A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 3R, 3-Pole, 600V w/ Bolt-on Closing Cap "H x 6.63"W x 4.88"D 60A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 3R, 3-Pole, 600V w/ Bolt-on Closing Cap "H x9"w x 6.38"D 100A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 3R, 3-Pole, 600V w/ Bolt-on Closing Cap "H x 8.5"W x 6.38"D 200A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 3R, 3-Pole, 600V w/ Bolt-on Closing Cap "H x 17.25"W x 8.5"D 400A Heavy Duty Disconnect Switch, Single Throw, Non-Fusible, NEMA 3R, 3-Pole, 600V "H x 27.88"W x 10.13"D Square D - Disconnect/Safety Switch Accessories Electrical - Distribution & Controls Ground Bar Kit - QO GTK03 Square D GTK03 Service Grounding Kit Field installable ground lug, Al/Cu. Disconnect switch size: 60A. Max Voltage: 600V. For use with heavy duty safety switches/series F1, F5 through F7. Wire Size: #12 to #4 AWG. QOGTK03 Ground Bar Kit - QO GTK0610 Field Installable Ground Lug, 60A, Series F Only Field installable Service Grounding Kit - QOGTK0610 Safety Switch Ground Bar Kit for F Series heavy duty safety switches. 100 Amps maximum switch rating. Wire size (AWG): (2) #1/0 Al/Cu Max. UL Listed QOGTK0610 Handle Mechanism - QO 9422A1 Field Installable Service Grounding Kits, 100A Switch Rating Handle Mechanism Kit - QO9422A1 6" Handle Mechanism for use with 30 to 200A Switches and all Circuit Breaker Mechanisms. Suitable for right or left hand flange mounting. Use with Nema 1/3/3R/4(sheet steel)/12 Enclosures QO9422A1 6" Handle Mechanism for 30 to 200A Switches and all CB Mechanisms Does Not Contain Clearance Items 126

129 Motor Controls - Contactors - Switches - Disconnects Square D - Safety Switches & Handle Mechanisms Square D - Disconnect/Safety Switch Accessories Interlock Kits- QO EIKx QOEIK031 QOEIK1 Electrical Interlock Kits - QO EIKx For heavy duty or general duty safety switches. Each kit contains instructions for proper field mounting. A pivot arm operates from switch mechanism, breaking the control circuit before the main switch blades break. Action: SPDT Neutral Assembly - QO H200SN 30A Electrical Interlock Kit for Safety Switches for F1, F5-F7 Series, 1NO 1NC A Electrical Interlock Kit for Safety Switches, For F2-F7 Series Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects Neutral Assembly - QOH200SN 200 Amp Solid neutral assembly for safety switches, aluminum / copper. Insulated and Groundable QOH200SN 200A Solid Neutral Assembly Neutral Assembly - QO H600SN Neutral Assembly - QO H600SN Standard Neutral Assembly, solid for use with heavy duty safety switches/series E1 through E4. For fusible and not fusible 240 and 600 Volt Safety Switches. (Neutrals cannot be installed in 4-pole, 6-pole, or Nema 4X fiberglass reinforced polyester safety switches.) Series No. E1-E4. Terminal Data: (4) 750 Max. Al/Cu, (1) 300 Max. Al/Cu. QOH600SN Neutral Assembly - QO SN03 400A & 600A Solid Neutral Assy, Standard Kit for Fusible and Not Fusible Safety Switches Safety Switch Neutral Assembly - QOSN03 30 Amp Standard Neutral Kit. Field installable Neutral Assembly for fusible and non-fusible 240 and 600 Volt Safety Switches (Neutrals cannot be installed in 4-Pole, 6-Pole, or Nema 4X fiberglass reinforced polyester safety switches) Series No. F1, F5-F6. Terminal Data: (3) #2 Max. Al/Cu. QOSN03 Neutral Assembly - QO SN A Neutral Assembly for Safety Switches - Series # F1, F5-F6 Safety Switch Neutral Assembly - QOSN Amp & 100 Amp switch rated Standard Neutral Kit. Field installable Neutral Assembly for fusible and non-fusible 240 and 600 Volt Safety Switches. (Neutrals cannot be installed in 4-pole, 6-pole, or Nema 4X fiberglass reinforced polyester safety switches.) 60A Series No. F1-F3, F5-F6 (600V). 100A Series No. F2-F6. 60A Terminal Data: (2) #1/0 Max. Al/Cu, (2) #2 Max. Al/Cu. 100A Terminal Data: (2) #1/0 Max. Al/Cu, (2) #6 Max. Al/Cu. QOSN A and 100A Standard Neutral Assembly for Safety Switches Does Not Contain Clearance Items 127

130 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Safety Switches & Handle Mechanisms Square D - Disconnect/Safety Switch Accessories Neutral Assembly - QO SN20A QOSN20A Safety Switch Neutal Assembly - SN20A 200A switch rating Standard Neutral Kit. Field installable Neutral Assemblies for fusible and non-fusible 240 and 600 Volt Safety Switches. (Neutrals cannot be installed in 4-pole, 6-pole, or Nema 4X fiberglass reinforced polyester safety switches.) Series # F5-F6. Terminal Data: (2) 250 Max. Al/Cu., (1) #1/0 Max. Al/Cu Square D - Handle Mechanisms Flush Lock Kit - QO PK4FL 200A Standard Neutral Assembly for Safety Switches - Series # F5-F6 Electrical - Distribution & Controls Panelboard Flush Lock - QOPK4FL Use with 300 and 400 Amp indoor load centers QOPK4FL Operating Mechanism - QO 9421LL1 Flush Lock Kit For Use With 300 and 400A Indoor QO Load Centers Square D LL1 Operating Mechanism, including lockout for circuit breaker or interrupter type LAL, LHL, Q4L. 400 Amp, 2-3 poles, Nema rated. QO9421LL1 Operating Mechanism for LAL/LHL/Q4L Breakers, 600VAC, 400AMP Operating Mechanism Handle - QO 9421LH46 Square D LH46 Nema Type 3 and 4, 6" standard, Handle Assembly. For use with Circuit Breaker or Interrupter Type GJL, FAL, FCL, FHL, KAL, KCL, KHL, LAL, LHL, Q4L. Frame Size: 75 Amps, 100 Amps, 250 Amps, 400 Amps. Painted flat black with a silver base ring. QO9421LH46 Standard Operating Mechanism Handle, 6" Length, Black Does Not Contain Clearance Items 128

131 Motor Controls - Contactors - Switches - Disconnects Square D - Safety Switches & Handle Mechanisms Square D - Handle Mechanisms Operating Mechanism Long Shaft - QO 9421LS12 QO9421LS12 Square D LS12 Operating Mechanism Long Shaft, support bracket included. For use with Circuit Breaker or Interrupter Type: GJL, FAL, FCL, FHL, KAL, KCL or KHL, 2 or 3 Poles. Product Destination: 9421LF1 or LK1 operating mechanism. Operating Mechanism, Long Shaft w/ Support Bracket Square D - Switches & Drives Altivar AC Drive - Motor Control Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects Altivar AC Drive QOATV312HU40N4 Square D Altivar 312 AC Drive - ATV312HU40N4 A cost-effective adjustable speed control for asynchronous motors with a horsepower rating of 5.0. Autotuning, multiloaders and 50 pre-loaded application functions to manage common facility processes make setup and installation a breeze. Input voltage: 380/500Vac. 3-Phase input and output. Modbus and CANopen integrated communications ports. Ampere rating: 9.5A. Degree of protection: IP20. Motor power rating: 4.0kW. Operating Temperature: 14 F to 122 F. UL/CSA listed, CE Marked QOATV312HU40N4 Drum Switch 5HP, 9.5A, 380/500Vac, 3-Phase, Altivar 312 AC Drive Drum Switch QO2601AG2 Square D AG2 Drum Switch Drum switch reversing, 3-pole, 600 Vac / 250 Vdc. Designed to start and reverse motors by connecting them directly across-the-line. Standard one-piece operator. Horsepower rating (1-phase): 1.5HP@115VAC - 2HP@230VAC. Horsepower Rating (3-phase): 2HP@200/575VAC. Flush mount. Enclosure rating: NEMA 1 QO2601AG2 Drum Switch Reversing, 3-Pole, 600 Vac / 250 Vdc, NEMA 1 Float Switch Float Switch QO9036DG2 Square D DG2 Float Switch Type D, 1 HP, Float Switch for open tank or sump applications. Action: Contacts close on liquid rise. Contact Arrangement: DPST. Enclosure Rating: NEMA 1. Force up to trip: 9 ounces. Force Down to Trip: 8 ounces. Maximum Voltage Rating: 575VAC. Mounting Type: Bracket. No. of Poles: 2-Pole. Terminal Type: Screw ClampForce Down to Trip: 8 ounces QO9036DG2 Float Switch, 2-Pole, Single Lever Operated - Contacts Close on Liquid Rise, NEMA 1 Does Not Contain Clearance Items 129

132 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Switches & Drives Foot Switch Foot Switch QO9002AW2 QO9002AW2 Square D AW2 Foot Switch Type A Heavy Duty Industrial Foot Switch. Indoor/Outdoor oiltight, water tight, dust tight and drip tight enclosure. Nema 2, 4 and 13. Single Pole, Double throw, 600Vac, 5Amp. With Pedal Shield and Side Shields. Connection Type: 0.75" NPT (Conduit Entrance). Operator Action: Spring Return. Contact arrangement: SPDT Limit Switches & Accessories Square D Lever Arms w/ Roller 1-Pole Spring Return Foot Switch w/ Petal Shield and Side Shields Electrical - Distribution & Controls Square D Lever Arms with Roller Heavy duty industrial limit switch lever arms with standard roller. Plug-in body metal. Cast zinc lever arm. Steel roller. Roller Orientation: Standard (Outside) QO9007BA1 QO9007CA11 QO9007DA11 QO9007MA1 QO9007MA11 Lever Arm w/ Steel Roller for Limit Switch - 1-3/8" Arm Length - Roller 5/8" Dia. x 1/4" W Lever Arm w/ Steel Roller for Limit Switch - 2" Arm Length - Roller 3/4" Dia. x 1/4" W Lever Arm w/ Steel Roller for Limit Switch - 2-1/2" Arm Length - Roller 3/4" Dia. x 1/4" W Lever Arm w/ Steel Roller for Limit Switch - 1-1/2" Arm Length - Roller 5/8" Dia. x 1/4" W Lever Arm w/ Steel Roller for Limit Switch - 1-1/2" Arm Length - Roller 3/4" Dia. x 1/4" W Square D AO1 & 2 Snap Switches Square D AO Snap Switches Quick Make and Break Snap Action Industrial Switches. 600Vac, 15Amp. Contact Type: 1 NO / 1 NC. Type of Actuator: Button. Operating Force (Oz.): 7.00 to Mounting Dimension: 2.1" Bolt Center Distance. UL, CSA, CE Listed. QO9007AO1 1 N.O. - 1 N.C. Snap Action Switch, 600Vac, 15A, Max Pretravel: 0.074", Max Differential Travel: 0.025" QO9007AO2 1 N.O. - 1 N.C. Snap Action Switch, 600Vac, 15A, Max Pretravel: 0.074", Max Differential Travel: 0.046" Square D AW12 Non Plug-in Square D AW12 Limit Switch Standard non plug-in precision type limit switch. 600VAC., 15A. Contact Configuration: 1 N.O. - 1 N.C. Contact Operation: Snap Action. Contact Form: Form Z - SPDT-DB. Head Type: Rotary. Acuation: Counter clockwise. Actuatior and Action: Momentary, Lever Arm (order separately). Total Travel: 30. Enclosure rating: NEMA 1/2/4/12/13. QO9007AW12 Limit Switch, SPDT Contact, 15A, 600V, Non-Plug-in, 1 N.O. - 1 N.C., Order Lever Arm Separately Does Not Contain Clearance Items 130

133 Motor Controls - Contactors - Switches - Disconnects Square D - Switches & Drives Limit Switches & Accessories Square D C Heavy Duty Switches QO9007C52B2 QO9007C54A2 QO9007C54B2 QO9007C62B2 QO9007C68T10 Square D C Heavy Duty Limit Switches The 9007C heavy duty limit industiral switches are rugged, dependable, and easy to install. NEMA A600, 600V, 10 Amp continuous. Oil tight, dust tight, and water tight. Accurate and precise repeatability. 90 total travel helps prevent shaft and lever arm breakage. Lever Rotation: CW AND CCW. Connection Type: 1/2" NPT. UL, CSA and CE Listed. Square D FA1 Rod Lever Arm Electrical - Distribution & Controls 600V 10A, Plug-in Limit Switch, Compact Body, Rotary Operated, Std. Pre-travel - Spring Return, 1-Pole, 1 NO/1 NC, Order Lever Arm Separately 600V 10A, Plug-in Limit Switch, Std. Body, Rotary Operated, Low Differential - Spring Return, 1-Pole, 1 NO/1 NC, Order Lever Arm Separately 600V 10A, Plug-in Limit Switch, Std. Body, Rotary Operated, Std. Pre-travel - Spring Return, 1-Pole, 1 NO/1 NC, Order Lever Arm Separately 600V 10A, Plug-in Limit Switch, Std. Body, Rotary Operated, Std. Pre-travel - Spring Return, 2-Pole, 2 NO/2 NC, Order Lever Arm Separately 600V 10A, Plug-in Limit Switch, Std. Body, Rotary Operated / Neutral Position, Std. Pre-travel - Spring Return, 2-Pole, 2 NO/2 NC, Order Lever Arm Separately Motor Controls - Contactors - Switches - Disconnects Square D FA1 Rod Type Lever Arm Heavy duty industrial rod type lever arm for rotary operated heads on limit switches. Stainless Steel Rod. Operator Diameter: 1/8". Arm Length: 10". QO9007FA1 10" Stainless Steel Rod Type Lever Arm for Rotary Heads on Limit Swiches Square D FA5 Spring Rod Lever Arm Square D FA5 Spring Rod Lever Arm Heavy duty industrial limit switch spring rod lever arm. Material: DELRIN (plastic) looped rod arm. Spring Rod Length: 12". Operator Diameter: 1/8". QO9007FA5 12" DELRON Spring Rod Type Lever Arm for Limit Switches Square D HA1 Adjustable Lever Arm Square D HA1 Adjustable Lever Arm Heavy duty industrial adjustable length lever arm for limit switches. Non-Bendable. Arm/Rod Material: Standard (Cast Zinc). Adjustable Length: 7/8" to 4". Roller Material: Metal. Roller Dimensions: 5/8" Dia. x 1/4" W. Roller Orientation: Standard (Outside) QO9007HA1 Adjustable Lever Arm w/ Steel Roller for Limit Switch, Non Bendable - Arm Length 7/8" to 4" - Roller 5/8" Dia. x 1/4" W Does Not Contain Clearance Items 131

134 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Switches & Drives Limit Switches & Accessories Square D HA8 Adjustable Lever Arm QO9007HA8 Pressure Switches Square D HA8 Adjustable Lever Arm Heavy duty industrial adjustable length lever arm for limit switches. Bendable. Adjustable Length: 7/8" to 4". Nylon Roller Dimensions: 5/8" Dia. x 1/4" W. Roller Orientation: Standard (Outside) Adjustable Lever Arm w/ Nylon Roller for Limit Switch, Bendable - Arm Length 7/8" to 4" - Roller 5/8" Dia. x 1/4" W Square D GAW5 - Adj. Differential Electrical - Distribution & Controls Square D GAW5 Pressure Switch Type G Adjustable Differential Pressure Switch for Nema 4, 4X, 13 Enclosures. Used in pneumatic or hydraulic systems on a wide variety of machine and process applications to protect the equipment and control or monitor the system pressure. Electrical Connection: 1/2" 14 NPT. Switch Type: Single Stage. Max Voltage: 600V. Continuous Current Rating: 10A. Range on decreasing pressure: psig. Max. allowable pressure: 475 psig. Fluid Connection: 1/4" 18 NPTF (internal). Contact Arrangement: SPDT (isolated). Actuator Type: Diaphragm (low pressure). UL/CSA listed. QO9012GAW5 Adjustable Differential Industrial Pressure Switch, 10A, Single Pole Double Throw Square D FHG12J52X - For Compressors Square D FHG12J52X Compressor Pressure Switch Type FHG Pumptrol Compressor pressure switch. Designed for the control of small electrically driven air compressors. Contacts open on pressure rise, DPST. Diaphragm actuated. Nema 1 enclosure. Adjustable cut out range increasing pressure: psig. Approximate differential non-adjustable: 30 psig. Poles: 2-Pole. Pressure connection: 1/4 NPSF internal. Pressure Setting: Off at 125 psig. HP Rating 1 phase: 1-1/2 HP@115VAC - 2HP@230VAC. HP Rating 3 phase: 2HP@115VAC - 3HP@230VAC - 1HP@460/575VAC. Special Feature: 2-Way pressure release valve. QO9013FHG12J52X Compressor Pressure Switch, 2-Pole, Nema 1, 575VAC Max, Off at 125 PSIG, w/ 2-Way Pressure Release Valve Square D FHG2J27M1 - For Compressors Square D FHG2J27M1 Compressor Pressure Switch Type FHG Pumptrol Compessor pressure switches are designed for the control of small electrically driven air compressors. Contacts open on pressure rise, DPST. Diaphragm actuated. NEMA 1 enclosure. Adjustable cut out range increasing pressure: 40 to 100 PSIG. Approximate differential non-adjustable: 20 psig. Poles: 2-Pole. Pressure connection: 1/4" NPSF internal. Pressure Setting: Off at 100 psig. HP Rating 1 Phase: 1.5HP@115VAC - 2HP@230VAC. HP Rating 3 Phase: 2HP@115VAC - 3HP@230VAC - 1HP@460/575VAC. Special Feature: Maintained manual cut-out lever (Auto-Off). QO9013FHG2J27M1 Compressor Pressure Switch, 2-Pole, Nema 1, 575VAC Max, Off at 100 PSIG, w/ Maintained Manual Cut-out Lever Does Not Contain Clearance Items 132

135 Motor Controls - Contactors - Switches - Disconnects Square D - Switches & Drives Pressure Switches Square D FRG72J23 - For Water Pumps QO9013FRG72J23 Square D FRG72J23 Water Pump Pressure Switch Type FRG Pumptrol Water Pump Pressure Switches are reverse acting; contacts open on falling pressure. Designed for control of electrically driven water pumps. Contact arrangement: SPST. Diaphragm actuated. NEMA 1 enclosure. 1- Pole. Cut-in Range: psig. Approx. adustable differential: psig. Cut-out Range: psig. Pressure Connection: 1/4" NPSF Internal. Pressure Setting: Close at 40 PSIG - Open at 20 PSIG. HP rating 1-phase: 1HP@115/230VAC. Water Pump Pressure Switch, 1-Pole, Nema 1, 575VAC Max, Reverse Action, Contacts Open on Falling Pressure Square D FSG22J20M - For Water Pumps Electrical - Distribution & Controls Square D FSG22J20M Water Pump Pressure Switch Type FSG Pumptrol standard pressure switches are designed for the control of all types of electrically driven water pumps: jets, submersible, reciprocating, etc. Contacts open on pressure rise. Contact arrangement: DPST. Diaphragm actuated. NEMA 1 enclosure. Cut-out Range: psig. Approximate adjustable differential: psig. Cut-in Range: psig. Poles: 2-Pole. Pressure Connection: 1/4" NPSF Internal. Pressure Setting: 20 to 40 psig. HP Rating 1-Phase: 1.5HP@115VAC - 2HP@230VAC. HP Rating 3-Phase: 2HP@115VAC - 3HP@230VAC - 1HP@460/575VAC. Special Feature: Maintained manual cut-out lever (Auto-Off). Motor Controls - Contactors - Switches - Disconnects QO9013FSG22J20M Water Pump Pressure Switch, 2-Pole, NEMA 1, 575VAC Max, Standard Action, psi, w/ Maintained Manual Cut-out Lever Square D FSG2J20 - For Water Pumps Square D FSG2J20 Water Pump Pressure Switch Type FSG Pumptrol standard pressure switches are designed for the control of all types of electrically driven water pumps: jets, submersible, reciprocating, etc. Contacts open on rising pressure. Contact arrangement: DPST. Disphragm actuated. Nema 1 Enclosure. Cut-out Range: psig. Approximate adjustable differential: psig. Cut-in Range: 5-45 psig. Poles: 2-Pole. Pressure Connection: 1/4" NPSF Internal. Pressure Setting: psi. HP Rating 1-Phase: 1.5HP@115VAC - 2HP@230VAC. HP Rating 3-Phase: 2HP@115VAC - 3HP@230VAC - 1HP@460/575VAC. QO9013FSG2J20 Water Pump Pressure Switch, 2-Pole, NEMA 1, 575VAC Max, Standard Action, psi Square D FSG2J20U - For Water Pumps Square D FSG2J20U Water Pump Pressure Switch Type FSG Pumptrol standard pressure switches are designed for the control of all types of electrically driven water pumps: jets, submersible, reciprocating, etc. Contacts open on rising pressure. Contact arrangement: DPST. Disphragm actuated. Nema 1 Enclosure. Cut-out Range: psig. Approximate adjustable differential: psig. Cut-in Range: 5-45 psig. Poles: 2-Pole. Pressure Connection: 1/4" NPSF Internal. Pressure Setting: psi. HP Rating 1-Phase: 1.5HP@115VAC - 2HP@230VAC. HP Rating 3-Phase: 2HP@115VAC - 3HP@230VAC - 1HP@460/575VAC. Special Feature: Slip-on connectors (load side terminals only). QO9013FSG2J20U Water Pump Pressure Switch, 2-Pole, NEMA 1, 575VAC, Std Action, psi, w/ Load Side Quick Connect Terminals Does Not Contain Clearance Items 133

136 Motor Controls - Contactors - Switches - Disconnects Motor Controls - Contactors - Switches - Disconnects Square D - Switches & Drives Pressure Switches Square D FSG2J21M4 - For Water Pumps QO9013FSG2J21M4 Square D FSG2J21M4 Water Pump Pressure Switch Type FSG Pumptrol standard pressure switches are designed for the control of all types of electrically driven water pumps: jets, submersible, reciprocating, etc. Contacts open on rising pressure. Contact arrangement: DPST. Disphragm actuated. Nema 1 Enclosure. Cut-out Range: psig. Approximate adjustable differential: psig. Cut-in Range: 5-45 psig. Poles: 2-Pole. Pressure Connection: 1/4" NPSF Internal. Pressure Setting: psi. HP Rating 1-Phase: 1.5HP@115VAC - 2HP@230VAC. HP Rating 3-Phase: 2HP@115VAC - 3HP@230VAC - 1HP@460/575VAC. Special Feature: Low pressure cut-off (Auto-Start-Off) Operates at approximately 10 psig below cut-in and will turn off the pump. Water Pump Pressure Switch, 2-Pole, NEMA 1, 575VAC Max, Std. Action, psi, w/ Low Pressure Cut-Off Square D FSG2J21U - For Water Pumps Electrical - Distribution & Controls QO9013FSG2J21U Square D FSG2J21U Water Pump Pressure Switch Type FSG Pumptrol standard pressure switches are designed for the control of all types of electrically driven water pumps: jets, submersible, reciprocating, etc. Contacts open on rising pressure. Contact arrangement: DPST. Diaphragm actuated. Nema 1 Enclosure. Cut-out Range: psig. Approximate adjustable differential: psig. Cut-in Range: 5-45 psig. Poles: 2-Pole. Pressure Connection: 1/4" NPSF Internal. Pressure Setting: psi. HP Rating 1-Phase: 1.5HP@115VAC - 2HP@230VAC. HP Rating 3-Phase: 2HP@115VAC - 3HP@230VAC - 1HP@460/575VAC. Special Feature: Slip-on connectors (load side terminals only). Water Pump Pressure Switch, 2-Pole, NEMA 1, 575VAC Max, Std. Action, psi, w/ Load Side Quick Connect Terminals Square D FSG2J24U - For Water Pumps QO9013FSG2J24U Square D 9013FSG2J24U Water Pump Pressure Switch Type FSG Pumptrol standard pressure switches are designed for the control of all types of electrically driven water pumps: jets, submersible, reciprocating, etc. Contacts open on rising pressure. Contact arrangement: DPST. Diaphragm actuated. Nema 1 Enclosure. Cut-out Range: psig. Approximate adjustable differential: psig. Cut-in Range: 5-45 psig. Poles: 2-Pole. Pressure Connection: 1/4" NPSF Internal. Pressure Setting: psi. HP Rating 1-Phase: 1.5HP@115VAC - 2HP@230VAC. HP Rating 3-Phase: 2HP@115VAC - 3HP@230VAC - 1HP@460/575VAC. Special Feature: Slip-on connectors (load side terminals only). Water Pump Pressure Switch, 2-Pole, NEMA 1, 575VAC Max, Std. Action, psi, w/ Load Side Quick Connect Terminals Square D GHG2J57 - Water Pump/Air Comp. Square D GHG2J57 Pressure Switch Type GHG Pressure Switch is designed for the control of electrically driven water pumps and air compressors. These devices cover higher electrical ratings for directly controlling motors in pump and compressor applications. Cut-out Range: psig. Approx. Adjustable Differential: Cut-in Range: psig. Poles: 2-Pole. NPSF Internal Pressure Connection: 1/4. Pressure Setting: psi. HP Rating 1-Phase: 2HP@115VAC - 3HP@230VAC - 5HP@460/575VAC. HP Rating 3-Phase: 3HP@115VAC - 5HP@230VAC - 5HP@460/575VAC. QO9013GHG2J57 Water Pump & Air Compressor Pressure Switch, 2-Pole, NEMA 1, 575VAC Max, Std. Action, psi Does Not Contain Clearance Items 134

137 Motor Controls - Contactors - Switches - Disconnects Square D - Switches & Drives Pressure Switches Square D GHG2J57X - Water Pump/Air Comp. QO9013GHG2J57X Square D GHG2J57X Pressure Switch Type GHG Pressure Switch is designed for the control of electrically driven water pumps and air compressors. These devices cover higher electrical ratings for directly controlling motors in pump and compressor applications. Cut-out Range: psig. Approx. Adjustable Differential: Cut-in Range: psig. Poles: 2-Pole. NPSF Internal Pressure Connection: 1/4. Pressure Setting: psi. HP Rating 1-Phase: 2HP@115VAC - 3HP@230VAC - 5HP@460/575VAC. HP Rating 3-Phase: 3HP@115VAC - 5HP@230VAC - 5HP@460/575VAC. Special Feature: Twoway pressure release valve (not compatible with Form E). Water Pump & Air Compressor Pressure Switch, 2-Pole, NEMA 1, 575VAC Max, Std. Action, psi, w/ 2-Way Pressure Release Valve Panelboards Cutler-Hammer Pow-R-Line Panelboards & Accessories Cutler-Hammer - Panelboard Accessories Electrical - Distribution & Controls Motor Controls - Contactors - Switches - Disconnects Cutler-Hammer BK Circuit Breaker Kits Cutler-Hammer Circuit Breaker Kits Main circuit breakers or subfeed circuit breakers for unassembled panelboards. Includes circuit breaker and terminals. Single or Three Phase. C-HBKED200T 200A, 240V Max, Main Circuit Breaker or Subfeed Circuit Breaker Kit, 1 or 3 Phase, ED Frame, Top Mount Cutler-Hammer Filler Plate Cutler-Hammer - Panelboard Accessories C-H5155C62H01 Filler Plate, Covers for GB, GHB, GHBS, BAB, Breakers, PRL1A/PRL2A Cutler-Hammer Main Lug Feed-Through Lug Kit - 225A Cutler-Hammer 225A Lug Kit - LUGKIT Standard mechanical lug assembly. Can be used as main or Feed-Through distribution. Single or three-phase. Wire Range: (1) #6-300 kcmil. For use with PRL1A or PRL2A Panelboards. Includes: (3) Lugs, (1) Filler Cover, (6) x 7/8" Screws and (2) x 3/8" Screws. C-HLUGKIT A, Main Lug or Feed-Through Lug Kit, 1 or 3 Phase Does Not Contain Clearance Items 135

138 Panelboards Cutler-Hammer Pow-R-Line Panelboards & Accessories Cutler-Hammer - Panelboard Accessories Cutler-Hammer Main Lug Feed-Through Lug Kit - 400A Cutler-Hammer 400A Lug Kit - LUGKIT Standard mechanical lug assembly. Can be used as main or feed-through distribution. Single or three-phase. Wire Range: (2) #2-500 kcmil. For use with PRL1A or PRL2A Panelboards. Includes: (2) Lug Assembly for A & C, (1) Lug Assembly for B Phase, (1) Filler Cover, (1) Isolator for B Phase, (1) Isolator Cover, (9) x 1-1/4" Screws, (6) Nylon Fasteners and (2) x 3/8" Screws. Panelboards C-HLUGKIT A, Main Lug or Feed-Through Lug Kit, 1 or 3 Phase Cutler-Hammer QC6BP Breaker Mounting Plate Quicklag Type Mounting Plate 6-pole base mounting plate. Suitable for mounting six 1-pole, three 2-pole and two 3-pole breakers. C-HQC6BP 6-Pole Base Mounting Plate for Quicklag Type Breakers Cutler-Hammer SEK Service Entrance Kits Cutler-Hammer Service Entrance Kits - SEK For use with PRL1A and PRL2A Panelboards. 1-Phase or 3-Phase. Includes (1) Lug for up to 300 MCM and (1) conductor: copper stranded THHN. C-HSEK1/2 C-HSEK4/6 Cutler-Hammer Sub-Feed Breaker Kit 100A - Service Entrance Kit, 1 or 3 PH, for PRL1A or PRL2A Panel, Includes (1) Lug & #1 Copper Strd. THHN Conductor 400A - Service Entrance Kit, 1 or 3 PH, for PRL1A or PRL2A Panel, Includes (1) Lug & 1/0 Copper Strd. THHN Conductor Cutler-Hammer Sub-Feed Breaker Kit - 225ASFBKIT Sub-Feed breaker mounting kit. For use with 1 or 3-phase Type PRL1A or PRL2A interiors. C-H225ASFBKIT 225A, 1-3 Phase, Panelboard, Sub-Feed Breaker Kit - Type PRL1A/PRL2A Does Not Contain Clearance Items 136

139 Panelboards Cutler-Hammer Pow-R-Line Panelboards & Accessories Cutler-Hammer - Pow-R-Line Panelboards Cutler-Hammer EZ Box Panelboard Tub Cutler-Hammer Panelboard Tubs - EZB EZ Box Panelboard Tub. Galvanized Steel. Nema 1. Right hand hinge side for EZ trim. Not compatible with LT trims. C-HEZB2036RBS 36"H x 20"W x 5.75"D - Panelboard Tub Only, NEMA 1 C-HEZB2042RBS 42"H x 20"W x 5.75"D - Panelboard Tub Only, NEMA 1 C-HEZB2048RBS 48"H x 20"W x 5.75"D - Panelboard Tub Only, NEMA 1 C-HEZB2060RBS 60"H x 20"W x 5.75"D - Panelboard Tub Only, NEMA 1 C-HEZB2072RBS 72"H x 20"W x 5.75"D - Panelboard Tub Only, NEMA 1 C-HEZB2090RBS 90"H x 20"W x 5.75"D - Panelboard Tub Only, NEMA 1 Cutler-Hammer EZT Surface Covers Panelboards Cutler-Hammer Panelboard Surface Covers - EZT Surface mount EZ trim. Gray painted steel. Nema 1. Not compatible with YS boxes. C-HEZT2042S 20"W x 42"H - Surface Mount EZ Cover, NEMA 1 C-HEZT2048S 20"W x 48"H - Surface Mount EZ Cover, NEMA 1 C-HEZT2060S 20"W x 60"H - Surface Mount EZ Cover, NEMA 1 C-HEZT2072S 20"W x 72"H - Surface Mount EZ Cover, NEMA 1 Cutler-Hammer PRL1A Interiors Cutler-Hammer Panelboard Interiors - PRL1A Pow-R-Line Lighting Panelboard interior only (less main device). 240 Vac maximum. 100A Maximum branch breakers. Uses bolt on or plug on branch breakers. Each branch connector is capable of up to a total of 140A maximum by breaker ampere rating. Factory assembled. S = Short--no TFL or SFB provisions. UL Listed. C-H1A1225X42CS C-H1A1400X42C C-H1A3225X42C C-H1A3225X42CS C-H1A3400X42C Panelboard Interior (Less Main Device), 1-Phase 3-Wire, 225A, 42-Circuit, 120/240V, Copper Bus, Short (use 48"H Tub) Panelboard Interior (Less Main Device), 1-Phase 3-Wire, 400A, 42-Circuit, 120/240V, Copper Bus (Use 72"H Tub) Panelboard Interior (Less Main Device), 3-Phase 4-Wire, 225A, 42-Circuit, 208Y/120V, Copper Bus (Use 60"H Tub) Panelboard Interior (Less Main Device), 3-Phase 4-Wire, 225A, 42-Circuit, 208Y/120V, Copper Bus, Short (Use 48"H Tub) Panelboard interior (Less Main Device), 3-Phase 4-Wire, 400A, 42-Circuit, 208Y/120V, Copper Bus (Use 72"H Tub) Does Not Contain Clearance Items 137

140 Panelboards Cutler-Hammer Pow-R-Line Panelboards & Accessories Cutler-Hammer - Pow-R-Line Panelboards Cutler-Hammer PRL2A Interiors Cutler-Hammer Panelboard Interiors - PRL2A Pow-R-Line Lighting Panelboard interior only (less main device). 480Y/277 Vac maximum (125Vdc). 100A maximum branch breakers. Bolt-on branch breakers. Each branch connector is capable of up to a total of 140A maximum by breaker ampere rating. Factory assembled. S=Short--no TFL or SFB provisions. UL listed. Panelboards C-H2A3225X42C C-H2A3225X42CS C-H2A3400X42C Panelboard Interior (Less main Device), 3-Phase 4-Wire, 225A, 42-Circuit, 480Y/277V, Copper Bus (Use 60"H Tub) Panelboard Interior (Less main Device), 3-Phase 4-Wire, 225A, 42-Circuit, 480Y/277V, Copper Bus, Short (Use 48"H Tub) Panelboard Interior (Less main Device), 3-Phase 4-Wire, 400A, 42-Circuit, 480Y/277V, Copper Bus (Use 72"H Tub) Square D - I-Line Panelboards & Accessories I-Line Accessories I-Line Accessories - Blank Extensions - QO HLW Square D - Blank Panelboard Extensions Blank extensions for I-Line Panelboards. Type HCP/HCR-U. Extensions attach to the "wide side" of an I-Line deadfront and are only used in panels that are made to accept L,M.N,PG,PJ, PL, RG,RJ, RL frame circuit breakers. The extensions fill the gap between the end of the blank and the edge of the deadfront branch circuit breaker opening QOHLW1BL QOHLW4BL 1-1/2" - Panelboard Blank Extension I-Line 3ea/Box (for replacement purposes) 4-1/2" - Panelboard Blank Extension I-Line 5Ea/Box I-Line Accessories - Blank Fillers - QO HNM Square D - Blank Fillers for I-Line Panelboards The fillers cover blanks or spaces on the interior and are installed on the I-Line mounting pads QOHNM1BL QOHNM4BL 1-1/2" - Blank Fillers - for I-Line Panelboards 3ea/Box 4-1/2" - Blank Fillers - Covers 3 1-Pole Spaces, for I-Line Panelboards 5Ea/Box I-Line Accessories - Ground Bar Kit - QO PK32DGTA Square D - PK32DGTA Ground Bar Kit Panelboard Ground Bar Kit for I-Line Merchandised Panelboards. HCM, HCP, HCR-U QOPK32DGTA Equipment Ground Bar Kit for I-Line Panelboards - HCM, HCP, HCR-U Does Not Contain Clearance Items 138

141 Panelboards Square D - I-Line Panelboards & Accessories I-Line Accessories I-Line Accessories - Solid Neutral Assembly - QO HC4SN Square D - HC4SN Neutral Assembly Solid Neutral Assembly for I-Line Panelboards. 400 Mains Ampere Rating. Main Lug Terminals Lug Range: (2) #4-600 kcmil Cu or Al QOHC4SN 400A Solid Neutral Assembly I-Line Panelboard Enclosure Box Panelboards I-Line Boxes - QO HC I-Line Panelboard Boxes - QOHCx Nema 1 Box for I-Line Merchandised Panelboards. Main lug and main breaker interiors. Galvanized Steel QOHC2652B 26"W x 52"L - Box for I-Line Merchandised Panelboard, Nema 1 QOHC2674B 26"W x 74"L - Box for I-Line Merchandised Panelboard, Nema 1 QOHC3248B 32"W x 48"L - Box for I-Line Merchandised Panelboard, Nema 1 QOHC3264B 32"W x 64"L - Box for I-Line Merchandised Panelboard, Nema 1 Square D - NF & NQ Panelboards & Accessories Square D MH Boxes Square D - MH Boxes 20" Wide Square D MH Panelboard Enclosures Indoor Enclosures 20" Wide x 5.75" Deep. 600A main lug interior max. or 400A main circuit breaker max. Galvanized steel with removeable endwalls. With Knockouts: The one endwall is provided with knockouts and other other endwall is blank. "BE" suffix means NO KNOCKOUTS. QOMH26 QOMH26BE QOMH32 QOMH32BE QOMH38 QOMH38BE QOMH44 QOMH44BE QOMH50 QOMH50BE QOMH56 QOMH56BE QOMH62 QOMH62BE QOMH68 NEMA 1 Panelboard Enc. Box Only - 26" H X 20" W X 5 3/4" D NEMA 1 Panelboard Enc. Box Only - 26" H X 20" W X 5 3/4" D (NO KNOCKOUTS) NEMA 1 Panelboard Enc. Box Only - 32" H X 20" W X 5 3/4" D NEMA 1 Panelboard Enc. Box Only - 32" H X 20" W X 5 3/4" D (NO KNOCKOUTS) NEMA 1 Panelboard Enc. Box Only - 38" H X 20" W X 5 3/4" D NEMA 1 Panelboard Enc. Box Only - 38" H X 20" W X 5 3/4" D (NO KNOCKOUTS) NEMA 1 Panelboard Enc. Box Only - 44" H X 20" W X 5 3/4" D NEMA 1 Panelboard Enc. Box Only - 44" H X 20" W X 5 3/4" D (NO KNOCKOUTS) NEMA 1 Panelboard Enc. Box Only - 50" H X 20" W X 5 3/4" D NEMA 1 Panelboard Enc. Box Only - 50" H X 20" W X 5 3/4" D (NO KNOCKOUTS) NEMA 1 Panelboard Enc. Box Only - 56" H X 20" W X 5 3/4" D NEMA 1 Panelboard Enc. Box Only - 56" H X 20" W X 5 3/4" D (NO KNOCKOUTS) NEMA 1 Panelboard Enc. Box Only - 62" H x 20" W x 5-3/4" D NEMA 1 Panelboard Enc. Box Only - 62" H x 20" W x 5-3/4" D (NO KNOCKOUTS) NEMA 1 Panelboard Enc. Box Only - 68" H X 20" W X 5 3/4" D Does Not Contain Clearance Items 139

142 Panelboards Square D - NF & NQ Panelboards & Accessories Square D MH Boxes Square D - MH Boxes 20" Wide QOMH68BE Square D NC Covers NEMA 1 Panelboard Enc. Box Only - 68" H X 20" W X 5 3/4" D (NO KNOCKOUTS) Panelboards Square D - NC Covers 20" Wide Square D NC Covers 20" Wide covers for Nema 1 NF Merchandised Panelboards. Steel construction. QONC26S Mono Flat Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 26"H QONC26SHR Hinged Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 26"H QONC32F Mono Flat Front Flush Mount Cover Only for Nema 1 Enc., 20"W x 32"H QONC32S Mono Flat Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 32"H QONC32SHR Hinged Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 32"H QONC38S Mono Flat Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 38"H QONC38SHR Hinged Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 38"H QONC44S Mono Flat Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 44"H QONC44SHR Hinged Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 44"H QONC50S Mono Flat Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 50"H QONC50SHR Hinged Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 50"H QONC50VS Vented, Mono Flat Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 50"H QONC56S Mono Flat Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 56"H QONC62VS Vented, Mono Flat Front Surface Mount Cover Only for Nema 1 Enc., 20"W x 62"H Square D NF & NQ Accessories Square D - EFP Filler Plate Square D - EFP Filler Plate NF Merchandised Panelboard Filler Plate. Compatible with Series 0 NF interiors. QOEFP Filler Plate for NF Merchandised Panelboards Class 1670 Square D - HPAFD Handle Lockoff Square D - HPAFD Circuit Breaker Handle Padlock Attachment Removeable padlock attachment for NF Series circuit breakers. Locks OFF only. For circuit breaker type ED, EG, EJ. 1, 2 or 3 Poles. Short circuit current rating: Vac. QOHPAFD Handle Padlock Attachment - Looks Off - Circuit Breaker Type ED, EG, EJ Does Not Contain Clearance Items 140

143 Panelboards Square D - NF & NQ Panelboards & Accessories Square D NF & NQ Accessories Square D - NF Neutral Lug Kits Square D NF Neutral Lug Kits Oversized lugs for neutral or ground bar. Field Installed. QO70AN 70A Neutral Lug Kit, #10 to #2 Al or #14 to #4 Cu Wire QOQ1100AN Neutral Lug Kit, #4 to #1/0 AL/CU Wire QOQ1150AN Neutral Lug Kit, #1 to #4/0 AL/CU Wire Square D - NFFP15 Filler Plates Panelboards NF Filler Plate Kit - Square D NFFP15 Single pole filler plates for the Series E1 NF merchandised panelboards. 15 per Pkg. QONFFP15 NF Filler Plate Kit - 15 Pack Square D - NQFP15 Filler Plate Square D NQFP15 Filler Plate For use with NQ panelboards. Package of 15. QONQFP15 NQ Filler Plate Kit - 15 Pack Square D NF Covers Square D - NC38F Panelboard Cover Square D NF Covers QONC38F 20" W X 38" H - Panelboard Enclosure Flush Cover, Type 1 Does Not Contain Clearance Items 141

144 Panelboards Square D - NF & NQ Panelboards & Accessories Square D NF Main Circuit Bkr. Adapter Kits Square D - N150MH Main Circuit Breaker Adapter Kit - QON150MH NF Panelboard Main Breaker Kit for H-Frame, HDL, HGL, HJL and HLL. Main Circuit Breaker not included. For single phase applications of HDL and HGL, select a 3-pole main circuit breaker. For single phase applications of HJL and HLL, select a 2-pole main circuit breaker. RTI kit accepts maximum 125A H-frame circuit breaker. Panelboards QON150MH A Max. Main Breaker Adapter Kit, Less Breaker Type HDL,HGL, HJL, HLL Square D - N250MJ Main Circuit Breaker Adapter Kit - QON250MJ NF Main Circuit Breaker Kit (less circuit breaker). Ampere Rating: A. For use with J Frame CB only. Circuit Breaker Frame Type: JDL, JGL, JJL, JLL. QON250MJ Square D - N400M 250A Main Circuit Breaker Adapter Kit Less Breaker, use w/ J Frame CB only Main Circuit Breaker Adapter Kit - QON400M NF Main Breaker Kit (less circuit breaker) Bus Ampacity: 400A. Max voltage rating: 480 single phase 3-wire, 480Y/277 three phase 4-wire. AIR Value: 30000, Breaker Ampacity: 125, 150, 175, 200, 225, 300, 350, 400. Breaker Frame Type: LH, LA, LAL, LHL. QON400M Square D NF Main Lug Interior Square D - NF Main Lug Interiors A Max. Main Breaker Adapter Kit, Less Breaker, Frame Type LAL, LHL Square D NF Main Lug Interiors NF Merchandised Panelboards interiors only for 20" box width. Max voltage rating: 480Y/277. Three phase, 4-wire. Linear load type. Copper Bussing. Uses single pole EDB circuit breakers. For Nema 1, 3R, 5 and 12 style flush or surface mount enclosures. Order branch circuit breakers separately. QONF418L1C QONF430L2C QONF442L2C QONF442L4C 125A, 18 Max # of 1-Pole EDB Breakers, 3-Phase, 4-Wire Copper Bussing Main Lug Only Interior. Use with MH Boxes 250A, 30 Max # of 1-Pole EDB Breakers, 3-Phase, 4-Wire Copper Bussing Main Lug Only Interior. Use with MH Boxes 250A, 42 Max # of 1-Pole EDB Breakers, 3-Phase, 4-Wire Copper Bussing Main Lug Only Interior. Use with MH Boxes 400A, 42 Max # of 1-Pole EDB Breakers, 3-Phase, 4-Wire Copper Bussing Main Lug Only Interior. Use with MH Boxes Does Not Contain Clearance Items 142

145 Panelboards Square D - NF & NQ Panelboards & Accessories Square D NQ Main Breaker Kits NQMB Square D - NQMB2Q Square D NQMB2Q Main Circuit Breaker Adapter Kit Ampere Rating A. For Main Circuit Breakers QBL,QDL, QGL, and QJL. (Main circuit breakers are not included in the adapter kits. Order circuit breaker separately.) Kit contents: A. Main circuit breaker deadfront cover (1). B. Main circuit breaker mounting pan (1). C. Deadfront support brackets (2). D. "Main" circuit breaker label (1). E x 7/16" tappling screws (2). F x 5/16" tapping screws (6). G x 2-1/4" tapping screws (2). QONQMB2Q NQ Main Circuit Breaker Adapter Kit, A Square D - NQMB4LA Panelboards Square D Panelboard Feed-Thru-Lug Kits Feed-thru-lug kit for NQ panelboards. Kit is used for low circuit count interiors 30 and 42. QONQMB4LA NQ Main Circuit Breaker Adapter Kit, A Square D QO Main Lug Feed-Thru Kits Square D - NQ Feed-Thru-Lugs Kit Square D NQ Main Lug Interiors 1-Phase, 3-Wire Class 1640 Main Lug Interior Only, 240 Vac, 48 Vdc. For NQ Merchandised Panelboards. Accepts plug-on and bolt-on circuit breakers. Interior Only, order branch circuit breakers separately. 20" wide cabinet. 1-Phase, 3-Wire, copper bussing. QONQFTL2L QONQFTL4L Square D QO Main Lug Interior 225A Feed-Thru-Lugs Kit for NQ Panelboards, 30/42 Circuits 400A Feed-Thru-Lugs Kit for NQ Panelboards, 30/42 Circuits Square D - NQ Main Lug Interiors 1-Phase Square D NQ Main Lug Interiors 1-Phase, 3-Wire Class 1640 Main Lug Interior Only, 240 Vac, 48 Vdc. For NQ Merchandised Panelboards. Accepts plug-on and bolt-on circuit breakers. Interior Only, order branch circuit breakers separately. 20" wide cabinet. 1-Phase, 3-Wire, copper bussing. QONQ18L1C QONQ42L2C 100A, 18 Space, 1-Phase, 3-Wire NQ Main Lug Interior, Copper Bussing 225A, 42 Space, 1-Phase, 3-Wire NQ Main Lug Interior, Copper Bussing Does Not Contain Clearance Items 143

146 Panelboards Square D - NF & NQ Panelboards & Accessories Square D QO Main Lug Interior Square D - NQ Main Lug Interiors 3-Phase Square D NQ Main Lug Interiors 3-Phase, 4-Wire Class 1640 Main Lug Interior Only, 240 Vac, 48 Vdc. For NQ Merchandised Panelboards. Accepts plug-on and bolt-on circuit breakers. Interior Only, order branch circuit breakers separately. 20" wide cabinet. 3-Phase, 4-Wire. Copper bussing. Panelboards QONQ418L1C QONQ430L1C QONQ430L2C QONQ442L2C QONQ442L4C QONQ484L2C 100A, 18 Space, 3-Phase, 4-Wire NQ Main Lug Interior, Copper Bussing 100A, 30 Space, 3-Phase, 4-Wire NQ Main Lug Interior, Copper Bussing 225A, 30 Space, 3-Phase, 4-Wire NQ Main Lug Interior, Copper Bussing 225A, 42 Space, 3-Phase, 4-Wire NQ Main Lug Interior, Copper Bussing 400A, 42 Space, 3-Phase, 4-Wire NQ Main Lug Interior, Copper Bussing 225A, 84 Space, 3-Phase, 4-Wire NQ Main Lug Interior, Copper Bussing Pushbutton & Indicating Lights Cutler-Hammer - Pushbuttons - Selector Switches - Indicating Lights Cutler-Hammer T 30.5mm Heavy-Duty Watertight/Oiltight Pushbutton Accessories - C-H 10250T-Series Cuttler-Hammer Pushbutton Accessories C-H10250TA46 C-H10250TA7 Clear Boot for 30.5mm Flush Pushbutton Hole Plug for Unused Pushbutton Holes 30.5mm, Painted Gray Steel w/gasket Pushbutton Enclosure Case & Cover C-H 10250TN Cutler-Hammer Pushbutton Enclosures 10250TN 30.5mm Heavy-duty, watertight/oiltight. Die cast enclosure - In-line NEMA 4 4X, 12,13. Includes case and cover. Suface mounting C-H10250TN1 C-H10250TN2 1-Hole 30.5mm Pushbutton Enclosure Case & Cover Surface Mounting, 1-Contact Block Depth 2-Hole 30.5mm Pushbutton Enclosure Case & Cover Surface Mounting, 1-Contact Block Depth Does Not Contain Clearance Items 144

147 Pushbutton & Indicating Lights Cutler-Hammer - Pushbuttons - Selector Switches - Indicating Lights Cutler-Hammer T 30.5mm Heavy-Duty Watertight/Oiltight Pushbutton Indicator Light Units C-H 10250T Cutler Hammer Indicator Light Units 10250T 30.5mm heavy-duty watertight/oiltight Indicating Light Units. UL (NEMA) Type 3, 3R, 4, 4X, 12, 13 C-H10250T181N C-H10250T184N C-H10250T34G C-H10250TC19N C-H10250TC1N C-H10250TC22 C-H10250TC2N 30.5mm Indicator Light, Incandescent Lamp, Standard Operator, 120VAC Transformer Type, NO LENS 30.5mm Indicator Light, Incandescent Lamp, 480VAC Transformer Type, AC Only - NO LENS 30.5mm Green Indicator Light, Incandescent Lamp, 120Vac-Transformer type, with lens 30.5mm Amber Plastic Lens Only for Indicator Light 30.5mm Red Plastic Lens Only for Indicator Light Green Lens for 30.5mm T10250T Illuminated Pushbuttons 30.5mm Green Plastic Lens Only for Indicator Light Pushbutton Operator Legend Plates - C-H10250TR2/TM Cutler-Hammer Legend Plates 10250TMx Sized for all standard commercial enclosures. For pushbutton operators and indicating lights or selector switch and rotopush operators, standard size Pushbutton & Indicating Lights C-H10250TM33 C-H10250TM34 C-H10250TM42 C-H10250TM51 C-H10250TR2 1/2 Round Legend Plate, "START", Black Background, for Pushbuttons & Indicating Lts 1/2 Round Legend Plate, "STOP", Red Background, for Pushbuttons & Indicating Lts 1/2 Round Legend Plate, "OFF/ON", Black Background, for Selector Switch and Roto-Push Operators 1/2 Round Legend Plate, "HAND/OFF/AUTO", Black Background, for Selector Switch and Roto-Push Operators 1/2 Round Legend Plate for Push-Pull Unit, PULL START / PUSH STOP Pushbutton Operators - NON-Illuminated C-H 10250T-Series Cutler-Hammer Non-illuminated Momentary Pushbuttons 30.5mm heavy-duty watertight/oiltight. UL (NEMA) Type 3, 3R, 4, 4X, 12, 13 C-H10250T101 C-H10250T102 C-H10250T103 C-H10250T111 C-H10250T112 C-H10250T113 C-H10250T122 C-H10250T17213 Momentary Pushbutton Operator, Non-Illuminated, Black Flush Button Momentary Pushbutton Operator, Non-Illuminated, Red Flush Button Momentary Pushbutton Operator, Non-Illuminated, Green Flush Button Momentary Pushbutton Operator, Non-Illuminated, Black Extended Button Momentary Pushbutton Operator, Non-Illuminated, Red Extended Button Momentary Pushbutton Operator, Non-Illuminated, Green Extended Button Momentary Pushbutton Operator, Non-Illuminated, Red Mushroom Button Momentary Pushbutton Operator, Non-Illuminated, Red Jumbo Mushroom Button, Emerg. Stop Does Not Contain Clearance Items 145

148 Pushbutton & Indicating Lights Cutler-Hammer - Pushbuttons - Selector Switches - Indicating Lights Cutler-Hammer T 30.5mm Heavy-Duty Watertight/Oiltight Pushbutton Station Contact Blocks C-H 10250T Cutler-Hammer 10250T Contact Blocks Additional Contact Blocks for pushbutton control stations. 30.5mm operators. Press-term Pushbutton & Indicating Lights C-H10250T1 C-H10250T2 C-H10250T3 C-H10250T51 C-H10250T53 1NO/1NC Contact Block for Pushbutton Control Stations 2NO Contact Block for Pushbutton Control Stations 2NC Contact Block for Pushbutton Control Stations 1NC Contact Block for Pushbutton Control Stations 1NO Contact Block for Pushbutton Control Stations Push-Pull Operator Components C-H 10250T Cutler-Hammer Push-Pull Operators 10250T 30.5mm heavy-duty watertight/oiltight push-pull operators without lens C-H10250T4 C-H10250T5 C-H10250T5-51 C-H10250T63 C-H10250TB62 C-H10250TB63 C-H10250TC47 C-H10250TJ62 C-H10250TJ63 Three-Position Momentary Push-Pull Operator without Lens, 30.5mm Two-Position Maintained Push-Pull Operator withouts Lens, 30.5mm, No Intermediate Position Two Position 1NC-Cont. Push-Pull Operator without Lens, 30.5mm Light Unit for Illuminated Push-Pull Devices, 120V Transformer AC only 50/60Hz Red Button for Push-Pull Operator, Non-Illuminated, Standard 40mm Red Button w/ EMERGENCY STOP for Push-Pull Operator, Non-Illuminated, Standard 40mm Red Lens for Illuminated Push-Pull Devices, Standard Size Red Jumbo Mushroom Head for Non-Illuminated Push-Pull Devices, Aluminum Red (EMERG. STOP) Jumbo Mushroom Head for Non-Illuminated Push-Pull Devices, Aluminum Selector Switch Key Operator C-H 10250T15113 Cutler-Hammer 10250T15113 Key Operator 30.5mm Heavy-duty watertight/oiltight Selector Switch Key Operator with cam. Two-position maintained - 60 throw. Vertical mounting. Key removal position: right and left. UL (NEMA) Type 3, 3R, 4, 4X, 12, 13 C-H10250T15113 Two-Position Maintained Selector Switch Key Operator w/ Cam1 Does Not Contain Clearance Items 146

149 Pushbutton & Indicating Lights Cutler-Hammer - Pushbuttons - Selector Switches - Indicating Lights Cutler-Hammer T 30.5mm Heavy-Duty Watertight/Oiltight Selector Switches 3-Position C-H 10250T21KB Cutler-Hammer 3-Position Selector Switches 30.5mm heavy-duty watertight/oiltight Selector Switch Unit. Positions: Three-position maintained C-H10250T21KB Selector Switches w-caps 2-Pos. C-H C-H10250T1311 C-H10250T3011 Three-Position Maintained Selector Switch, Black Knob, Non-Illuminated Cutler-Hammer 2-Position Selector Switch 30.5 mm heavy-duty watertight/oiltight Selector Switch Operators with caps. Two-position maintained 60 throw. Black knob. UL (NEMA) Type 3, 3R, 4, 4X, 12, 13 Selector Switches w-caps 3-Pos. C-H Two-Position Maintained Selector Switch Operator w/ Cap, CAM1, Black Knob Two-Position Maintained Selector Switch Operator w/ Cap, CAM1, Black Lever Pushbutton & Indicating Lights Cutler-Hammer 3-Position Selector Switch w/caps 30.5mm heavy-duty watertight/oiltight Selector Switch Operators with caps. Positions: Three-position maintained or maintained with spring return, 60 throw. Black Knob or Black Lever. UL (NEMA) Type 3, 3R, 4, 4X, 12, 13 C-H10250T1323 C-H10250T1343 C-H10250T3023 C-H10250T3043 Three-Position Maintained Selector Switch Operator w/ Cap, CAM3, Black Knob Three-Position Spring Return, S-M-S, Selector Switch Operator w/ Cap, CAM3, Black Knob Three-Position Maintained Selector Switch Operator w/ Cap, CAM3, Black Lever Three-Position Spring Return, S-M-S, Selector Switch Operator w/ Cap, CAM3, Black Lever Cutler-Hammer - 22M Series Pushbuttons & Selector Switches M22 Selector Switch Key-Operated - C-H Cutler-Hammer M22 Selector Switches - M22-WRS Key-operated, non-illuminated, selector switches for 22.5mm modular pushbuttons. Silver Bezel. Key Code: MS1. Includes one key. Includes contact block mounting adapter. NEMA 4X and 13 Cutler-Hammer 22M Modular Pushbuttons Eaton's M22 line features a wide offering of functional, attractive and ergonomically designed illuminated and nonilluminated pushbuttons, selector switches, push-pulls, alternate action and twist-to-release operators. C-HM22ESMS1 C-HM22WRSA1 REPLACEMENT KEY for M22 Series, Key Code MS1 Key Operated M22 Selector Switch, 2-Pos. Maintained, Key Removeable Left Does Not Contain Clearance Items 147

150 Pushbutton & Indicating Lights Cutler-Hammer - Pushbuttons - Selector Switches - Indicating Lights Cutler-Hammer - 22M Series Pushbuttons & Selector Switches M22-CK10 Contact Block C-H M22CK10 Cutler-Hammer M22 Series Contact Block M22-CK mm Contact Block. 1 N.O. Front Mount. Spring cage terminal type Pushbutton & Indicating Lights C-HM22CK mm Contact Block, 1 N.O. M22S-DH-R Modular Pushbutton Non-Illum. C-H M22SDHRK10 C-HM22SDHRK10 Cutler-Hammer Non-illuminated Momentary Pushbutton M22S-DH-R-K mm modular pushbutton complete device. Non-illuminated, extended, momentary. Bezel: Black. Button Color: Red. Contact Block Configuration: 1 NO. Protection Type: IP67, IP69K, NEMA 4X, 13 Cutler-Hammer 22M Modular Pushbuttons Eaton's M22 line features a wide offering of functional, attractive and ergonomically designed illuminated and nonilluminated pushbuttons, selector switches, push-pulls, alternate action and twist-to-release operators. 22mm Modular Pushbutton, Non-Illuminated, Red Extended, Momentary Cutler-Hammer - AC Pushbutton Switches Pushbutton Switches - C-H 8411K Cutler-Hammer 8411K Pushbutton Switches General-purpose, light duty, non-illuminated, pushbutton switches. Momentary contact. AC Rated. Bushing mounted. Slowmake/slow-break button type contacts with a light operating pressure. Rating: 3/4A, 125Vac/Vdc - 1/4A, 250 Vac/Vdc. Poles and Throw: 1 PST. Black nylon button. Comes with a bright nickel-plated hexagon facenut. RoHS, UL/CSA Certified C-H8411K11 C-H8411K7 Pushbutton Switch, Non-Illuminated, SPST, N/O, AC rated, 1/4" Spade Terminal Pushbutton Switch, Non-Illuminated, SPST, N/C, AC rated, Screw Terminal Cutler-Hammer - Pushbutton Control Stations Spec. Purpose Control Station C-H10250H364 Cutler-Hammer 10250H364 Special Purpose Control Station Two element flush pushbutton type control station. Legends: Start/Stop. UL (NEMA) Type 3, 3R, 4, 4X, 13 C-H10250H364 Two Element Pushbutton Control Station, Start/Stop, Nema 3R, 4X Does Not Contain Clearance Items 148

151 Pushbutton & Indicating Lights Cutler-Hammer - Pushbuttons - Selector Switches - Indicating Lights Cutler-Hammer - Pushbutton Control Stations Two Button Station - C-H10250H5200 Cutler-Hammer 10250H5200 Pushbutton Control Station Two button control station, NEMA type 1. Two element enclosure type. Flush/Red, Start/Stop C-H10250H Button Pushbutton Control Station, Stop/Start, Flush/Red Hubbell - Pushbuttons - Selector Switches - Indicating Lights Hubbell - Pushbutton Control Stations Hubbell - Two Button Pendant Station Hubbell CPB21 Two-Button Pendant Station Two-button compact pendant station. Single-speed with mechaical interlock between pushbuttons. NEMA 4X. UL Listed, CSA Certified Pushbutton & Indicating Lights HBLCPB21 Two-Button Compact Pendant Pushbutton Station, Single Speed w/ Mech. Interlock Square D - Push Buttons & Operator Interface 22mm 22mm Pilot Light Heads & Complete Bodies - XB4 22mm Pilot Light Complete Bodies- XB4 22mm Pilot Light Complete Bodies - XB4 QOZB4BV6 22mm Push Button Pilot Light Complete Body w/ Light Module & Mounting Collar, BA9 Bulb Not Included QOZB4BVBG5 22mm Push Button Pilot Light Complete Body w/ Light Module & Mounting Collar, Protected Yellow LED QOZB4BVG3 22mm Push Button Pilot Light Complete Body w/ Light Module & Mounting Collar, Protected Green LED QOZB4BVG4 22mm Push Button Pilot Light Complete Body w/ Light Module & Mounting Collar, Protected Red LED 22mm Pilot Light Heads - XB4 22mm Pilot Light Heads - XB4 QOZB4BV033 QOZB4BV043 22mm Pilot Light Head, Round, Standand Lens, Unmarked - Green 22mm Pilot Light Head, Round, Standand Lens, Unmarked - Red Does Not Contain Clearance Items 149

152 Pushbutton & Indicating Lights Square D - Push Buttons & Operator Interface 22mm 22mm Pilot Light Heads & Complete Bodies - XB5 22mm Pilot Light Heads - XB5 22mm Pilot Light Heads - XB5 Pushbutton & Indicating Lights QOXB5AVG3 22mm Pilot Light w/integral Green LED Light and Lens QOXB5AVG4 22mm Pilot Light w/integral Red LED Light and Lens QOXB5AVG5 22mm Pilot Light w/integral Yellow LED Light and Lens 22mm Push Button Heads 22mm Push Button Heads - XB4 22mm Push Button Heads QOZB4BA2 22mm Flush Push Button, Non-Illuminated, Black QOZB4BA3 22mm Flush Push Button, Non-Illuminated, Green QOZB4BA333 22mm Flush Push Button, Non-Illuminated, Green Cap w/ White "Start" QOZB4BA434 22mm Flush Push Button, Non-Illuminated, Red Cap w/ White "Stop" QOZB4BA9 22mm Flush Push Button, Non-Illuminated, w/ Six Color Caps QOZB4BC4 22mm Push Button, Non-Illuminated, w/ Red 40mm Mushroom Head QOZB4BL4 22mm Extended Push Button, Non-Illuminated, Red QOZB4BS844 22mm Turn-to-Release Maintained Push Button, Red 40mm Mushroom Head QOZB4BW33 22mm Flush Push Button, Illuminated, Green 22mm Push Button Heads - XB5 22mm Push Button Heads - XB5 QOXB5AA21 QOXB5AA31 QOXB5AA45 QOXB5AC21 QOXB5AS8445 QOZB5AA2 QOZB5AA4 QOZB5AW14 QOZB5AW15 QOZB5AW33 22mm Flush Push Button, Non-Illuminated, 1 NO, 10A - Black 22mm Flush Push Button, Non-Illuminated, 1 NO, 10A - Green 22mm Flush Push Button, Non-Illuminated, 1 NO, 1 NC, 10A - Red 22mm Push Button w/ 40mm Mushroom Head, Black, 1 NO Spring Return 22mm Push Button, Emergency Stop Device, 40mm Red Mushroom Head, 1 NO 1 NC Turn to Release 22mm Flush Push Button Head Only, Non-Illuminated, Black 22mm Flush Push Button Operator, Momentary, Non-Illuminated - Red 22mm Extended Push Button, Illuminated - Red 22mm Flush Push Button Head Only, Illuminated, Orange 22mm Flush Push Button, Illuminated, Green Does Not Contain Clearance Items 150

153 Pushbutton & Indicating Lights Square D - Push Buttons & Operator Interface 22mm 22mm Contact Blocks 22mm Contact Blocks QOZB4BZ101 QOZB4BZ102 QOZB4BZ103 QOZB4BZ105 QOZBE101 QOZBE1016 QOZBE102 QOZBE202 QOZBE205 22mm Mounting Base w/ Light - XB5 Type XB5 - Push Button Contact Block w/ Mounting Collar, 1 N.O. Type XB5 - Push Button Contact Block w/ Mounting Collar, 1 N.C. Type XB5 - Push Button Contact Block w/ Mounting Collar, 2 N.O. Type XB5 - Push Button Contact Block w/ Mounting Collar, 1 N.C. / 1 N.O. Type XB4 & XB5-22 mm Push Button, Add-on Single Contact Block, w/ Screw Clamp Terminal Connection, 1 N.O., 10A Type XB4 & XB5-22 mm Push Button, Add-on Single Contact Block, w/ Screw Clamp Terminal Connection, 1 N.O., 5A, Low Power Type XB4 & XB5-22 mm Push Button, Add-on Single Contact Block, w/ Screw Clamp Terminal Connection, 1 N.C., 10A Type XB4 & XB5-22 mm Push Button Contact Block, Late Break, 1 N.C., 10A Type XB4 - Push Button Double Contact Block, 1 N.C. / 1 N.O. Pushbutton & Indicating Lights Square D ZB5AVG Pilot Lights w/ Integral LED Harmony XB5 plastic 22mm push button pilot lights with integral LED. Screw clamp terminal connections. Supply Voltage: 110 to 120V, 50/60Hz. With protected LED. QOZB5AVG4 22mm Operator Selector Switches 22mm Mounting Base w/ Integral Red LED, 120V, (Lens not included) 22mm Operator Selector Switches QOXB5AD33 22mm Selector Switch, Non-Illuminated, Standard Knob, 3-Maintained Positions, Black QOZB4BD2 22mm Selector Switch, Non-Illuminated, Standard Knob, 2-Maintained Positions, Black QOZB4BD3 22mm Selector Switch, Non-Illuminated, Standard Knob, 3-Maintained Positions - Black QOZB5AD3 22mm Selector Switch, Non-Illuminated, Standard Knob, 3-Maintained Positions - Black 22mm Push Button Parts & Accessories 22mm Push Button Parts & Accessories QODL1BEG QOZB2BE101 Type XVB - Incancescent Lamp, 7W, 120V, BA15D Bayonet Base Type XB2-22mm Pushbutton & Selector Switch Contact Block, 10A, 600V, 1 N.O. Spring Return, 1-Speed Does Not Contain Clearance Items 151

154 Pushbutton & Indicating Lights Square D - Push Buttons & Operator Interface 22mm 22mm Push Button Parts & Accessories Pushbutton & Indicating Lights QOZB2BE102 QOZB4BZ009 QOZB5AZ009 QOZBP0A QOZBPA QOZBVBG1 QOZBVG4 22mm Standard Legend Plates QOZBY2330 QOZBY2367 QOZBY2387 Type XB2-22mm Pushbutton & Selector Switch Contact Block, 10A, 600V, 1 N.C. Spring Return, 1-Speed Type XB4-22 mm Metallic Mounting Collar For Use w/ Electrical Block Type XB5-22mm Plastic Mounting Collar For Use w/ Electrical Block Type XB4 & XB5-22mm Clear Circular Single Boot (Food Industry Application) Silicone Type XB4 & XB5-22mm Transparent Circular Single Boot (Food Industry Application) Silicone Type XB4 & XB5-22mm Pilot Light & Push Button Light Module, 24/120V, NEMA Rating 1-4, & 12-13, White LED Type XB4-22mm Pilot Light & Push Button Light Module, 110/120V, NEMA Rating 1-4, & 12-13, Red LED Square D - Standard Legend Plates Standard (30 x 40mm) Legend Plates for 8 x 27mm Legends. Text "Emergency Stop" in white letters on red background. Text "OFF / ON" black with white letters. Text "OFF HAND AUTO" black with white letters Standard Legend Plate Red w/ White Letters "EMERGENCY STOP" Standard Legend Plate Black w/ White Letters "OFF - ON" Standard Legend Plate Black w/ White Letters "HAND-OFF-AUTO" Square D - Push Buttons & Operator Interface 30mm 30mm Contact Blocks - Class 9001 S30mm Contact Blocks - Class 9001 QO9001KA1 30mm Double-Break, Direct-Acting, Pushbutton Contact Block, 1 NO - 1 NC, Clear Cover QO9001KA1G 30mm Pushbutton Contact Block, 1 NO - 1 NC, Not Fingersafe, Clear Cover QO9001KA2 30mm Pushbutton Contact Block, 1 NO, Fingersafe, Double-Break, Direct Acting, Green Cover QO9001KA3 30mm Pushbutton Contact Block, 1 NC, Fingersafe, Double-Break, Direct-Acting, Red Cover 30mm Control Stations - Class mm Control Stations - Class 9001 QO9001BG201 Control Station, 2-Button, Start-Stop, Surface Mount, Nema 1 QO9001BG305 Control Station, 3-Button, Up-Down-Start, Surface Mount, Nema 1 Does Not Contain Clearance Items 152

155 Pushbutton & Indicating Lights Square D - Push Buttons & Operator Interface 30mm 30mm Empty Enclosures - Class 9001 Square D KY1 Empty Enclosure Type KY Pushbutton Enclosure Only (for customer assembly). (1) 30mm Hole. Conduit Threads: NPT. Surface mount. Die cast aluminum. Nema 1, 3, 4 and 13. QO9001KY1 Enclosure Only for Contol Station, One 30mm Hole, Surface Mount 30mm Legend Plates - Class mm Legend Plates - Class 9001 QO9001KN200 Blank Aluminum Legend Plate For Use With Type K Operators QO9001KN201 "START" Aluminum Legend Plate For Use With Type K Operators QO9001KN202 "STOP" Aluminum Legend Plate For Use With Type K Operators - Red QO9001KN205 "EMERGENCY STOP" Aluminum Legend Plate For Use With Type K Operators - Red QO9001KN244 "OFF-ON" Aluminum Legend Plate For Use With Type K Operators QO9001KN245 "ON-OFF" Aluminum Legend Plate For Use With Type K Operators QO9001KN260 "HAND-OFF-AUTO" Aluminum Legend Plate For Use With Type K Operators QO9001KN8330 "EMERGENCY STOP" 90mm Circular Legend Plate for Mushroom Head - Yellow QO9001KN9330 "EMERGENCY STOP" 60mm Circular Legend Plate for Mushroom Head - Yellow 30mm Pendant Stations - Class 9001 Pushbutton & Indicating Lights 30mm Pendant Station - Class 9001 QO9001BW92Y Pendant Station w/ Mechanical Interlock, 2 Buttons Marked Up-Down, Yellow QO9001BW93Y Pendant Station, Two Buttons, Marked Forward/Reverse, Yellow QO9001BW95Y Pendant Station, Two Buttons, Marked Start/Stop, Yellow 30mm Pilot Lights & Lens 30 mm Pilot Lights & Lenses QO9001G31 QO9001KP1 30mm Pilot Light Lens, Plastic Fresnel - Green 30mm Heavy Duty Pilot Light w/o Color Cap, 110/120V, Transformer Style Does Not Contain Clearance Items 153

156 Pushbutton & Indicating Lights Square D - Push Buttons & Operator Interface 30mm 30mm Pilot Lights & Lens Pushbutton & Indicating Lights QO9001KP1G9 QO9001KP1R9 QO9001R31 QO9001SKP1 QO9001SKP38LGG9 QO9001SKP38LRR9 QO9001SKP38LYY9 30mm Potentionmeter - Class 9001 QO9001K mm Heavy Duty Pilot Light w/ Green Plastic Domed Lens, 110/120V, Transformer Style 30mm Heavy Duty Pilot Light w/ Red Plastic Domed Lens, 110/120V, Transformer Style 30 mm Pilot Light Lens, Plastic Fresnel - Red 30mm Standard Pilot Light, Corrosion Resistant, w/o Color Cap 30mm Standard Pilot Light, Corrosion Resistant, w/ Green Plastic Domed Lens, 120V 30mm Standard Pilot Light, Corrosion Resistant, w/ Red Plastic Domed Lens, 120V 30mm Standard Pilot Light, Corrosion Resistant, w/ Yellow Plastic Domed Lens, 120V 30mm Potentionmeter - Class 9001 Knob. Power Rating 2 W. Resistance 2500 Ohm. Nema 4/13. Size 30mm Model. Includes Operator With Single Pot, Dial Plate 30mm - Single Potentionmeter Knob, Type K 30mm Push Button Parts & Accessories 30mm Push Button Parts & Accessories Non-illuminated red, 30mm, push-pull knob. For KR8, KR9, SKR8 & SKR9 Operators QO9001G7 QO9001K7 QO9001KU1 QO9001KU2 QO9001KU7 QO9001R22 QO9001R7 30mm Push Buttons - Class mm - Push Button Illuminated Lens Cap - Green Padlock Attachment for 30mm Types K and SK Selector Switches & Potentiometers 30mm Protective Boot For Non-Illuminated Push Button - Black 30mm Protective Boot For Non-Illuminated Push Button - Red 30mm Protective Boot For Non-Illuminated Push Button - Clear 30mm Red Push Pull Knob for KR8, KR9, SKR8, SKR9 Operators 30mm - Push Button Illuminated Lens Cap - Red 30mm Push Buttons - Class 9001 Non-illuminated red, 30mm, push-pull knob. For KR8, KR9, SKR8 & SKR9 Operators QO9001K1L1G QO9001KR1U QO9001KR24R QO9001KR25R QO9001KR3R QO9001KR3U 30mm Illuminated Green Push Button Operator, w/o Contact Blocks 30mm Non-Illuminated, Push Button Operator, Momentary, Full Guard, with Color Inserts 30mm Non-Illuminated, Mushroom Push Button Operator With Set Screw, Red, Momentary Action 30mm Non-Illuminated, Mushroom Push Button Operator With Set Screw, Red, Momentary Action 30mm Non-Illuminated, Push Button Operator w/o Contact Blocks, Red, Momentary Action 30mm Non-Illuminated, Push Button Operator, Momentary, No Guard, with Color Inserts Does Not Contain Clearance Items 154

157 Pushbutton & Indicating Lights Square D - Push Buttons & Operator Interface 30mm 30mm Push Buttons - Class 9001 QO9001KR5B QO9001KR5R QO9001KR9 QO9001KR9P1 QO9001KR9R QO9001SK2L38LG QO9001SK2L38LR QO9001SK2L38LYY QO9001SKR1BH13 QO9001SKR1U QO9001SKR3U QO9001SKR9RH13 30mm Selector Switches - Class mm Non-Illuminated, Mushroom Push Button Operator, Black, No Contact Blocks 30mm Non-Illuminated, Mushroom Push Button Operator, Red, No Contact Blocks 30mm Non-illuminated Operator Maintained Pull - Maintained Push Pushbutton, No Knob 30mm Iluminated. Maintained Pull / Maintained Push, Mushroom Push Button Operator, No Knob 30mm Non-Illuminated, Mushroom Push Button Operator, Red, Maintained Push-Pull 30mm Push Button Light, Corrosion Resistant, w/ Cap - Green 30mm Push Button Light, Corrosion Resistant, w/ Cap - Red 30mm Push Button Light, Corrosion Resistant, w/ Cap - Yellow 30mm Non-Illuminated, Push Button Operator, Black, Emergency Stop Switch, SPDT, Momentary Spring Return 30mm Momentary Push Button Operator, Non-Illuminated, Full Guard, No Contacts, With Color Inserts 30mm Momentary Push Button Operator, Non-illuminated, No Guard, No Contacts, With Color Inserts 30mm Mushroom Pushbutton Operator, 2-Position, Non-Illuminated, Maintained 1 NO - 1 NC, Red 30mm Selector Switchs - Class mm Selector Switch Knob, black with a gloved-hand long handle. For 9001K or 9001SK Selector Switches Pushbutton & Indicating Lights QO9001B11 QO9001B25 QO9001KS11B QO9001KS11BH13 QO9001KS11FB QO9001KS11K3 QO9001KS42B QO9001KS43B QO9001KS43BH13 QO9001KS46B QO9001KS53B QO9001KS88B QO9001SKS11B QO9001SKS401B QO9001SKS43B QO9001SKS43BH13 30mm Standard Selector Switch Knob for K and SK Selector Switches, Black 30mm Selector Switch Knob for K and SK Selector Switches, Black, Gloved-Hand Long Handle 30mm Non-Illuminated Selector Switch, 2-Position Maintained, Black Knob 30mm Non-Illuminated Heavy Duty Selector Switch, 2 Position w/ Black Knob, Contact Block Included 30mm Non-Illuminated Selector Switch, Black Gloved-Hand Knob, 2-Position Maintained 30mm Non-Illuminated Key Operated Selector Switch, 2-Position Maintained, Black Knob 30mm Non-Illuminated, Selector Switch, 3-Position Maintained, Black Knob 30mm Non-Illuminated, Selector Switch, 3-Position Maintained, C Cam, Black Knob 30mm Non-Illuminated Selector Switch, 3-Position with Black Knob, Contact Block Included 30mm Non-Illuminated Selector Switch, 3-Position with Black Knob, No Contact Block 30mm Non-Illuminated Selector Switch, 3-Position with Black Knob, No Contact Blocks 30mm Non-Illuminated Selector Switch, 4-Position Maintained with Black Knob, No Contact Block 30mm Selector Switch, Non-Illuminated, 2-Position Maintained, w/ Standard Black Knob 30mm Selector Switch, Non-Illuminated, 3-Position Maintained, w/ Standard Black Knob 30mm Selector Switch, Non-Illuminated. 3-Position Maintained, w/ Standard Black Knob 30mm Non-Illuminated Selector Switch, 3-Position Maintained with Black Knob Does Not Contain Clearance Items 155

158 Transformers Cutler-Hammer - Dry Type - Low Voltage Transformers Cutler-Hammer 1-Ph Shielded Distribution Trans. Type EP - CH-HS20N11E Cutler-Hammer Encapsulated Transformers Single-phase sheilded, Type EP, general purpose encapsulated transformers. 240 x 480 Volts to 120/240 Volts. Suitable for indoor and outdoor applications. Totally enclosed non-ventilated enclosures. Rated NEMA 3R. Mountable in any position indoors and upright-only outdoors. 115 C rise standard. 60Hz operation. UL listed, CSA certified C-HS20N11E03A C-HS20N11E07A 3kVA Type EP Gen. Purpose Encapsulated Transformer, 1-Phase, 240x480 Volt to 120/240 Volt, Indoor-Outdoor "H x 7.69"W x 8"L 7.5kVA Type EP Gen. Purpose Encapsulated Transformer, 1-Phase, 240x480 Volt to 120/240 Volt, Indoor-Outdoor - 16"H x 10.38"W x 9.89"L Cutler-Hammer - Industrial Control Transformers Cutler-Hammer Control Transformers 240x C-HC Transformers Cutler Hammer Industrial Control Transformers Type MTE transformers with epoxy encapsulated coils. 50/60 Hz operation. Primary: 240 x 480, 230 x 460, 220 x 440 with jumpers. Secondary: 120/115/110 with fuse clips for 13/32 x 1-1/2 fuses. Provides stepped-down voltages to machine tool control devices, enabling control circuits to be isolated from all power and lighting circuits C-HC0050E2A C-HC0075E2A C-HC0100E2A C-HC0250E2A C-HC0500E2A 50VA Type MTE Industrial Control Transformer, Primary 240x480V, Secondary 120V 75VA Type MTE Industrial Control Transformer, Primary 240x480V, Secondary 120V 100VA Type MTE Industrial Control Transformer, Primary 240x480V, Secondary 120V 250VA Type MTE Industrial Control Transformer, Primary 240x480V, Secondary 120V 500VA Type MTE Industrial Control Transformer, Primary 240x480V, Secondary 120V Hammond - Industrial Control Transformers Hammond Mfg Control Transformer Hammond Mfg 185C230 Chassis Mount Power / Control Transformer - HAM 185C230 Dual primary 115/230 VAC. 50/60 Hz. operation. Dual secondaries: Series connections - 230V 0.11A; Parallel connections A. 4,000 V RMS Hipot test. Class F insulation. Chassis mount. Dual bobbin construction. Dual use terminals (solder lug or quick connect). cul us recognized, TUV Type Approved, and CE certified to IEC 950 HAM185C230 25VA, Dual Primary 115/230 VAC, Dual Secondary 230V Series / 115V Parallel Global Use Control Transformer Does Not Contain Clearance Items 156

159 Transformers SOLA - Industrial Control Transformers SOLA Control Transformer SOLA E150TE SOLAE150TE Sola/Hevi-Duty International Series Control Transformers, Group 2 Electromagnetic control components demand inrush currents up to 10 times the transformers nominal rating without sacrificing secondary voltage stability beyond practical limits. The International series transformers fully comply with IEC and NEMA standards. Epoxy encapsulated for cooler operation. Interleaved copper windings reduce I2R losses and maximize efficiently. 50/60 Hz. 55 C Rise, 105 C insulation system for harsh, heavy duty applications. Group 2: 208/240/415 Volt Primary, 24 Volt Secondary, 50/60 Hz; 277/480 Volt Primary, 24 Volt Secondary, 60 Hz; 200/230/400 Volt Primary, 24 Volt Secondary, 50/60 Hz; 220/380 Volt Primary, 23 Volt Secondary, 50/60 Hz 150VA, International Series Encapsulated Control Transformer, Multiple Primary, 24V Secondary Heavi-Duty SBE Series Control Transformers Sola SOLAE100 SOLAE150JN Sola/Hevi-Duty SBE Series Control Transformers SBE encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants. Extra deep, molded terminal barriers reduce the chance of electrical failure as the result of arcing or frayed lead wires. 55 C Rise, 105 C insulation system to minimize heat. Cooler Operating Temperature (50 to 55 C). Integrally molded, flame retardant terminal blocks. Heavy gauge steel mounting plate. Mounting dimensions are compatible with similar control transformers. Meets or exceeds NEMA Standard ST 1 and ANSI C89.1 for load inrush capability. UL/CSA listed 100VA, Type SBE Encapsulated Industrial Control Transformer, 240/480V Primary, 120V Secondary 150VA, Type SBE Encapsulated Ind. Control Transformer, 208/240/480/600V Primary, 120/24V Secondary, 60Hz (will only accept one FB2 secondary fuse holder) Square D - Dry Type Low Voltage Transformers Class 7400 Square D Transformers Square D - DASK Mechanical Lug Kits Square D - DASK Mechanical Lug Kits Primary and secondary transformer lug kits. 3 lugs per kit QODASKP100 QODASKP250 Primary Transformer Lugs, 1/0-14Str. Primary Transformer Lugs, 350 kcmil - 6Str. Square D - QO 1-PH Buck & Boost Transformers Square D Buck & Boost Dry Transformers Sealed, single-phase buck and boost transformers are isolating transformers that have 120 x 240 volt primaries, 60Hz, and 12/24 volt secondaries. When used as isolating transformers they carry the full load stated on the nameplate. It is also useful in applications where the primary and secondary are interconnected for use as an autotransformer. Autotransformers can carry loads in excess of their nameplate rating. Enclosure: Indoor / Outdoor, NEMA 3R. Mounting: Wall. NOTE: When used to supply a 3-phase, 4-wire load, the source must be 3-phase, 4-wire. QO150SV43A QO1S43F QO250SV43B QO50SV43A QO750SV43F.15kVA, Primary Voltage 120/240V, 12/24V Secondary, Sealed Buck and Boost Transformer 1.0kVA, Primary Voltage 120/240V, 12/24V Secondary, Sealed Buck and Boost Transformer.25kVA, Primary Voltage 120/240V, 12/24V Secondary, Sealed Buck and Boost Transformer.05kVA, Primary Voltage 120/240V, 12/24V Secondary, Sealed Buck and Boost Transformer.75kVA, Primary Voltage 120/240V, 12/24V Secondary, Sealed Buck and Boost Transformer Does Not Contain Clearance Items 157

160 Transformers Square D - Dry Type Low Voltage Transformers Class 7400 Square D Square D - QO 1-PH Sealed Gen.Purpose Transformers Square D - Sealed 1-Phase Transformers Low voltage transformers, single-phase, general purpose, dry type. Sealed and resin filled. 240 x 480 V primary, 120/240 V secondary, 60Hz. Intended for power, heating and lighting applications. Enclosure: Indoor/Outdoor, NEMA 3R. culus Listed. Transformers QO1.5S1F 1.5kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO10S1F 10kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO150SV1A.15kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO1S1F 1kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO250SV1B.25kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO2S1F 2kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO3S1F 3kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO500SV1B.50kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO50SV1A.05kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO5S1F 5kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO750SV1F.75kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC QO7S1F 7.5kVA, 1-PH, Dry Transformer, NEMA 3R, Primary 240x480VAC, Secondary 120/240VAC Square D - QO EE/EX Energy Efficient Transformers Square D - EE/EX Energy Efficient Low Voltage Transformers Class 7400 low voltage, general purpose, dry type, energy efficient transformers. Energy Efficient Transformers meet Table 4-2 of the Guide for Determining Energy Efficiency for Distribution Transformers, published by the National Electricial Manufacturers Assoc. (NEMA TP1-2002), set at 24-hour average loading of 35 percent. Single and three phase. Drip Proof (Indoor). Mounting Type: Floor - Ceiling or wall with mounting brackets. All units have 200% neutral to allow customers to feed standard and non-linear panels. 220 C UL listed insulation system. QOEE15S3H 15kVA, 1PH, Energy Efficient Transformer, Primary 240 X 480V, Secondary 120/240V QOEE25S3H 25kVA, 1PH, Energy Efficient Transformer, Primary 240 X 480V, Secondary 120/240V QOEE37S3H 37.5kVA, 1PH, Energy Efficient Transformer, Primary 240 X 480V, Secondary 120/240V QOEX75T3H 75kVA, 3PH, Energy Efficient Transformer, Primary 480V, Secondary 208Y/120V Square D - WMB36 Wall Mounting Brackets Square D - WMB36 Wall Mounting Brackets Wall mounting brackets for Class 7400 Transformers. Can only be used with units weighing no more than 700lbs QOWMB QOWMB Wall Mounting Bracket for Class 7400 Transformers, 15-30KVA 3P/1P 15KVA Wall Mounting Bracket for Class 7400 Transformers, 45/75-112KVA 3P/25-50KVA Does Not Contain Clearance Items 158

161 Transformers Square D - Dry Type Low Voltage Transformers Class 7400 Square D Square D - WS363 Weathershield Square D - WS363 Weathershield Weathershield for Class 7400, kva, Transformers QOWS363 Weathershield for Class 7400 Transformers Square D - Industrial Control Transformers Class 9070 Square D Square D EO Control Transformers QO9070EO1D1 Square D EO Control Transformers The Type EO units are designed with exceptional voltage regulation and very low temperature rise. These control transformers are constructed using traditional materials and manufacturing techniques. Temperature rise: 55 C. UL/CSA Listed Square D FB Fuse Blocks 60Hz, Control Transformer, Primary: 240/480V, Secondary: 120V Transformers Square D FB Fuse Blocks Field installed fuse options for industrial control transformers. Three pole fuse blocks for primary and secondary fusing. Accommodates 1-1/2" x 13/32" midget fuse (2 rejection and 1 non-rejection). QO9070FB3A QO9070FB3B VA, 3-Pole Fuse Block for Primary & Secondary Fusing, for 1-1/2" X 13/32" Midget Fuse VA, 3-Pole Fuse Block for Primary & Secondary Fusing, for 1-1/2" X 13/32" Midget Fuse Square D T Control Transformers Square D T Industrial Control Transformers Class 9070 Type T MultiTap units are available VA and are designed with various temperature classes VA with a 55 degrees C Temp. rise, VA with a 80 degrees C Temp. rise, VA with a 115 degrees C Temp. rise. All have a frequency of 50/60Hz. Features: Global-use transformer (UL, CSA, NOM, and CE), Trilingual nameplate and instructions (English, Spanish, and French), Molded terminal boards, and welded core and base plate. QO9070T1000D1 QO9070T100D1 QO9070T100D23 QO9070T100D3 QO9070T150D1 QO9070T150D23 QO9070T200D1 QO9070T250D1 1000V, 1PH, Control Transformer, Primary: 240/480V Secondary: 120V 100V, 1PH, Control Transformer, Primary: 240/480V, Secondary: 120V 100V, 1PH, Control Transformer, Primary: 120/240V, Secondary: 24V 100V, 1PH, Control Transformer, Primary: 208V, Secondary: 120V 150V, 1PH, Control Transformer, Primary: 240/480V, Secondary: 120V 150V, 1PH, Control Transformer, Primary: 120/240V, Secondary: 24V 200V, 1PH, Control Transformer, Primary: 240/480V, Secondary: 120V 250V, 1PH, Control Transformer, Primary: 240/480V, Secondary: 120V Does Not Contain Clearance Items 159

162 Transformers Square D - Industrial Control Transformers Class 9070 Square D Square D T Control Transformers QO9070T350D1 QO9070T500D1 QO9070T50D1 QO9070T50D23 QO9070T75D1 QO9070T75D23 350V, 1PH, Control Transformer, Primary: 240/480V, Secondary: 120V 500V, 1PH, Control Transformer, Primary: 240/480V, Secondary: 120V 50V, 1PH, Control Transformer, Primary: 240/480V, Secondary: 120V 50V, 1PH, Control Transformer, Primary: 120/240V, Secondary: 24V 75V, 1PH, Control Transformer, Primary: 240/480V, Secondary: 120V 75V, 1PH, Control Transformer, Primary: 120/240V, Secondary: 24V Square D TF Control Trans w/ Fuse Blocks Square D TF Control Transformers Type TF transformers have factory-installed overcurrent protection fuse blocks. Consists of two primary fuse blocks and one secondary fuse block, a configuration that meets the majority of overcurrent needs by panel builders and machinery OEMs. Fuse blocks are pre-wired and mounted on top of the transformer. Type TF transformer has the same footprint as the Type T transformer. This design frees up space normally used for separate fuse blocks. All have a frequency of 50/60 Hz. Transformers QO9070TF100D1 QO9070TF50D1 QO9070TF50D2 100V, 1PH, Control Transformer w/ Fuse Block, Primary: 240/480V, Secondary: 120V 50VA, 1PH, Control Transformer w/ Fuse Block, Primary: 240/480V, Secondary: 120V 50VA, 1PH, Control Transformer w/ Fuse Block, Primary: 240/480V, Secondary: 24V Does Not Contain Clearance Items 160

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 CH20CAFPN P 20A 20 Combo Arc Fault PN Breaker Eaton Corp Catalog Number Manufacturer Description Weight per unit Product

More information

CH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information

CH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information Manufacturer Description Weight per unit Product Category CH2AFIT 2P A Arc Fault Shared /Indpndt Trip BRKR Eaton Corp Features Current Rating AMPERE Interrupting Rating 10 KILOAMPERE Poles 2 Terminal Type

More information

SAFE REPLACEMENT BREAKERS BUILT TO LAST

SAFE REPLACEMENT BREAKERS BUILT TO LAST SAFE REPLACEMENT BREAKERS BUILT TO LAST Don t compromise on safety! Only Connecticut Electric manufactures NEW replacement circuit breakers that are Safety Agency Certified to UL489. Challenger Type A

More information

Section 8 Stab-lok Circuit Breakers

Section 8 Stab-lok Circuit Breakers Section 8 Stab-lok Circuit Breakers Stab-lok easier to work with and faster to install Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No.

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No. Square D Breakers American International Marketing P.O. Box 9133 Portland OR 97291-033 Closeout #1279-Square-D-Breakers Square D HOM230CP 30A DP Circuit Breaker (NEW) Square D #HOM230CP 30A DP Circuit

More information

Eylander Electric Inc

Eylander Electric Inc Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL

More information

22.000A IR. Catalog Number. Price $

22.000A IR. Catalog Number. Price $ Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Retail Reference Guide

Retail Reference Guide www.usa.siemens.com/retail Retail Reference Guide Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI) uses advanced electronic technology

More information

Type MP-T Type MP-HT Type MP-MT

Type MP-T Type MP-HT Type MP-MT CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

22,000 A IR Catalog Number QA115AFCH QA120AFCH Q215AFCH Q220AFCH. 65,000 A IR Catalog Number QA115AFCHH QA120AFCHH QA115AFH QA120AFH

22,000 A IR Catalog Number QA115AFCH QA120AFCH Q215AFCH Q220AFCH. 65,000 A IR Catalog Number QA115AFCHH QA120AFCHH QA115AFH QA120AFH 06/3/4 Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

Q115AFHn a Q120AFHn a. Q215AFCHn a Q220AFCHn a. QF115H a QF120Hn a QF130H QF215H QF220H QF230H QF240H QF250H QF260H

Q115AFHn a Q120AFHn a. Q215AFCHn a Q220AFCHn a. QF115H a QF120Hn a QF130H QF215H QF220H QF230H QF240H QF250H QF260H Arc-Fault and Ground-Fault s Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

Section 1. Load Centers and Circuit Breakers.  Section Updated 11 / 2014 Section Updated 11 / 2014 Q-Line Circuit Breakers Product Features and Benefits...1-2 PowerMark Gold Load Centers Product Features and Benefits...1-3 PowerMark Gold and Plus Load Centers Product Number

More information

Introduction. Upon completion of Basics of Circuit Breakers you will be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Circuit Breakers you will be able to: Explain the need for circuit protection Table of Contents Introduction... 2 Need for Circuit Protection... 4 Types of Overcurrent Protection Devices... 6 Circuit Breaker Design... 9 Types of Circuit Breakers... 20 Circuit Breaker Ratings...

More information

Section 4 Square D QO Loadcentres

Section 4 Square D QO Loadcentres Section 4 Square D QO Loadcentres The Choice of Professionals Square D service entrance loadcentres feature the rugged design, high quality and proven performance that residential, multi-residential and

More information

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

THQL1120AF2 THQL1120AF2 Arc Fault BRKR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND

More information

Modifications. Marine 50 C Ambient Calibration

Modifications. Marine 50 C Ambient Calibration 1-Pole Bolt-On (1V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 B1 B1H B1HH B1 B1H B1HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH 40 B140 B140H B140HH

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

Modifications. Marine 50 C Ambient Calibration

Modifications. Marine 50 C Ambient Calibration 1-Pole Bolt-On (120V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 15 B115 B115H B115HH 20 B120 B120H B120HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH

More information

Contents. 4 Loadcentres

Contents. 4 Loadcentres POWER PRODUCT Contents Application and Description -2 Product Offering and Specification Guide -3 Product Features and Customer Benefits - ing System -5 EQL & SEQ Single phase EQL with main lug -6 SEQ

More information

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND

More information

Section 3: Molded Case Circuit Breakers

Section 3: Molded Case Circuit Breakers Section : Molded Case Circuit Breakers Molded Case Circuit Breakers Features...-2 Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units Features...- Molded Case Circuit Breakers Quick Reference

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Panelboard Mounting with INSTA-WIRE 1-Pole Bolt-On (120V AC) e Bolt-On (Common-Trip 120/240V AC) f 10 B210 15 B215 B215H B215HH 20 B220 B220H B220HH 25 B225 B225Hn B225HHn 30 B230 B230H B230HH 35 B235

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application Product Offering and Specificaton Guide Application Main lug loadcentre, b Phase 3 W /V, to 0A, / - 0/80 circuits b 3 Phase W /8V, 00 to 5A, - circuits Main Breaker loadcentre, b Phase 3 W /V, to 0A, /

More information

Cutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF

Cutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF Cutler-Hammer Breakers American International Marketing Portland OR 97291-033 Closeout #1287-Cutler-Hammer-Breakers Cutler Hammer Ground-Fault Or Arc-Fault Breaker GFEP120 Cutler Hammer Ground-Fault Equipment

More information

FILE HOW TO REPLACE A GFCI BREAKER ARCHIVE

FILE HOW TO REPLACE A GFCI BREAKER ARCHIVE 07 February, 2018 FILE HOW TO REPLACE A GFCI BREAKER ARCHIVE Document Filetype: PDF 102 KB 0 FILE HOW TO REPLACE A GFCI BREAKER ARCHIVE Very first step as always when working with electricity is find the

More information

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3 Introduction P1 Panelboards P1 Feature Overview Key Panelboard Features Lighting and Appliance Applications Power Panelboard Applications Convertible From Top Feed to Bottom Feed and Vice Versa Change

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Boxes C  wide, 5 3 4 deep. C  wide, 5 3 4 deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3. Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

Division 1 Explosionproof Panelboards

Division 1 Explosionproof Panelboards Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Panelboards Circuit Breaker / Lighting and Distribution

Panelboards Circuit Breaker / Lighting and Distribution Circuit Breaker / Lighting and Distribution 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating 200,000 A. @ 240 Vac / 100,000 A. @

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS DIVISION 26 ELECTRICAL SECTION 26 28 19 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install circuit breakers in switchboards, distribution panelboards, and separate enclosures for overcurrent protection

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

X1PB: Explosionproof Panelboards

X1PB: Explosionproof Panelboards X1PB: Explosionproof FEATURES Spring-loaded through the door circuit breaker handles for 1P, 2P, and 3P breakers Padlock provision for breaker handles Copper bus bars Aluminum hinge with stainless steel

More information

Circuit Breakers. Lug-In/Lug-Out with INSTA-WIRE. Selection. Revised 03/06/13

Circuit Breakers. Lug-In/Lug-Out with INSTA-WIRE. Selection. Revised 03/06/13 Circuit Breakers Lug-In/Lug-Out with INSTA-WIRE 03/06/3 All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix L to catalog number. Consult Siemens

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

DOC / SQUARE D BREAKER BOX HINGES DOWNLOAD

DOC / SQUARE D BREAKER BOX HINGES DOWNLOAD 13 June, 2018 DOC / SQUARE D BREAKER BOX HINGES DOWNLOAD Document Filetype: PDF 224.03 KB 0 DOC / SQUARE D BREAKER BOX HINGES DOWNLOAD New in box Square D Thermal Magnetic Circuit Breaker FAL34020 Series.

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

GFCI-AFCI FAQ. Where are AFCIs and GFCIs required?

GFCI-AFCI FAQ. Where are AFCIs and GFCIs required? GFCI-AFCI FAQ What does an AFCI do? o An AFCI will shut down, or trip, a branch circuit when certain conditions are met. AFCIs monitor the circuit for arc faults, an unintentional electrical discharge

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes 12- Product Selection Table 12-33. s, H, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous

More information

Engine Generator Circuit Breakers

Engine Generator Circuit Breakers Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers Product Guide QR Circuit Breaker usa.siemens.com/circuitbreakers Advantages to reduce your cost and improve installation flexibility. 250A, 240V AC breakers up to 100kAIC. Updated design includes pushtotrip

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Molded Case Circuit Breakers LMD 800A Frame Sentron Series Type LMXD6 Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Blue Label Continuous 2-Pole (3 Pole Width) 3-Pole Current Rating

More information

Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P Distributed in the U.S.A. and Canada by Arterra Distribution Sales (574) 294-8997 Warranty Service (877) 294-8997 Fax

More information

CIRCUIT BREAKER PANELBOARDS

CIRCUIT BREAKER PANELBOARDS CIRCUIT BREAKER PANELBOARDS Class l, ones 1 & 2, Groups llb+h 2 Certified File LR 11713 for B7L FEATURES-SPECIFICATIONS Applications Hazardous locations due to the presence of flammable gases or vapors,

More information

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight ALPF Factory Sealed Lighting - APPF Power Distribution boards xplosionproof, Dust-Ignitionproof, Watertight NC: Class II, Division 1 and 2, Groups, F, G NA 4, 4X, 7BCD, 9FG Applications Distribution panelboards

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N R SERVICE MANUAL 50 AMP SMART EMS 50 Amp EMS Display Panel P/N 00-00684-000 LINE 1 LINE 2 6 5 4 3 2 1 6 5 4 3 2 1 M M 1 2 3 4 5 6 A I N A I N INVERTER LOADS SUBPANEL DANGER: HAZARD OF ELECTRICAL SHOCK

More information

Table of Contents. Review Answers...84 Final Exam...85 quickstep Online Courses...88

Table of Contents. Review Answers...84 Final Exam...85 quickstep Online Courses...88 Table of Contents Introduction...2 Need for Circuit Protection...4 Types of Overcurrent Protective Devices...8 Circuit Breaker Design... 11 Types of Circuit Breakers...23 Circuit Breaker Ratings...27 Time-Current

More information

1.3. Loadcenters and Circuit Breakers. Contents Description Standards and Certifications... Product Selection...

1.3. Loadcenters and Circuit Breakers. Contents Description Standards and Certifications... Product Selection... OEM Loadcenters Contents s and Certiications................. Product Selection......................... Page V-T-83 V-T-83 Product s a leader in the electrical distribution equipment business, Eaton has

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

SP 30A 120/240V CB. Features. Dimensions and Weight Height 3 Length Width 1. Long Description. Manufacturer Information

SP 30A 120/240V CB. Features. Dimensions and Weight Height 3 Length Width 1. Long Description. Manufacturer Information 3804 South Street 5964-263, TX Nacogdoches Phone: 936-569-94 Fax: 936-560-4685 AllenWatson@elliottelectric.com Q SP A /240V CB Siemens Energy Inc Manufacturer Description Weight per unit Product Category

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

Section 2 HomeLine Loadcentres

Section 2 HomeLine Loadcentres Section 2 HomeLine Loadcentres Features that Outclass the Competition The quality you expect from Schneider Electric, the industry leader, is built into all HomeLine loadcentres. One example is our exclusive

More information

2.3. Molded Case Circuit Breakers. Contents

2.3. Molded Case Circuit Breakers. Contents .3 Molded Case Circuit Breaker Product Family Product Overview Eaton s molded case circuit breakers are designed to provide circuit protection for low voltage distribution systems. They are described by

More information

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

Molded Case Circuit Breakers Reference Guide

Molded Case Circuit Breakers Reference Guide Molded Case Circuit Breakers Plug-In Breakers Panelboard Breakers QT QP, QPP QPH, QPPH HQP, HQPP HQPPH QPJ BL BLH HBL BQD, BQD NGB NEB HEB Page 1-25 1-27, 1-29 1-27, 1-29 1-24, 1-29 1-24, 1-29 1-29 -18-18

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

LCP Coordination Panel Operations & Maintenance Manual Table of Contents

LCP Coordination Panel Operations & Maintenance Manual Table of Contents LCP Coordination Panel Operations & Maintenance Manual Table of Contents Overview... NEC Requirements for Selective Coordination... LCP Datasheet... CCMR Series POWR-PRO Fuses - Datasheet... JTD Series

More information

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Pow-R-Line 3E Panelboard

Pow-R-Line 3E Panelboard This is a photographic template your photograph should fit precisely within this rectangle. Pow-R-Line 3E Panelboard 2008 Eaton Corporation. All rights reserved. Pow-R-Line 3E Panelboard Design guided

More information

Solar Combiner Solutions

Solar Combiner Solutions Solar Combiner Solutions Providing combiners and disconnects that offer superior resistance and durability from harsh weather and abusive solar environments Solar Technology Leading the way in Solar Technology

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

US CATALOG. ProLine Panelboard and breakers

US CATALOG. ProLine Panelboard and breakers US CATALOG ProLine Panelboard and breakers 2 PROLINE PANELBOARD AND BREAKERS PROLINE PANELBOARD AND BREAKERS 3 Table of contents 004 006 Description and features 007 008 Guides: and breaker placement 009

More information

Operator Manual For use with WFCO ULTRA III Distribution Center WF-8900 Series (model number located on the door assembly label)

Operator Manual For use with WFCO ULTRA III Distribution Center WF-8900 Series (model number located on the door assembly label) Operator Manual For use with WFCO ULTRA III Distribution Center WF-8900 Series (model number located on the door assembly label) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION Warranty Service

More information

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton Advances in technology to address safety Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton 1 Advances in technology could mean use existing technology & back to basics Advances in safety are

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

WF-8500 Series Power Centers

WF-8500 Series Power Centers Operator s Manual WF-8500 Series Power Centers WF-9900 Series WF-8540 WF-8550 WF-8560 ( The Power Center model number is located on the door assembly label ) Distributed in the U.S.A. and Canada by ARTERRA

More information

Wisconsin Area Catalog

Wisconsin Area Catalog Wisconsin Area Catalog Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank builds solutions that move

More information

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Arc Fault Circuit Interrupter (AFCI) FACT SHEET Arc Fault Circuit Interrupter (AFCI) FACT SHEET THE AFCI The AFCI is an arc fault circuit interrupter. AFCIs are newly-developed electrical devices designed to protect against fires caused by arcing faults

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information