H1 H2 H3 X0 X1 X2 X3

Size: px
Start display at page:

Download "H1 H2 H3 X0 X1 X2 X3"

Transcription

1

2

3

4 H0 H H H H0 H H H X0 X X X X0 X X X

5 S- S- S- S- FB

6

7

8

9

10

11

12 H0 H H H X0 X X X H0 H H H X0 X X X

13 7

14

15

16

17

18 NOTES:. ITEMS REMOVED FOR SHIPMENT. TANK DESIGNED FOR FULL VACUUM. MANUFACTURED IN ACCORDANCE WITH ANSI & NEMA. PAINT FINISH: ANSI #70 SKY GRAY EXTERIOR, WHITE INTERIOR 5. ALL DIMENSIONS IN INCHES 6. DESIGNED FOR -0 C 7. UNIT DESIGNED FOR RAIL SHIPMENT. MATCH-MARKED RADIATORS FOR PROPER REINSTALLATION 9. () EA SPARE HV, LV BUSHINGS 0. () SET SPARE GASKETS REQUIRED. UNDERCOAT BASE. UNIT TO BE FILLED WITH FR OIL 0 / 0 5 X0 BUSHING, ABB,.5-UN-A (SILVER PLATED THREAD), #05W0AT, 5 KV, CORE GROUND BUSHING, CENTRAL MALONEY #7055 (WITH GROUND PAD & 6 DOMED NON-SKID COVER, WELDED 7 LIFTING LOOP FOR LIFTING COVER ONLY LV SURGE ARRESTER MOUNTING 9 HV SURGE ARRESTER MOUNTING 0 DELTA STAR LOGO MAIN TRANSFORMER NAMEPLATE (STAINLESS STEEL) BOLTED MANHOLE COVER WITH FLUSH LIFTING HANDLES, Ø" ROUND OPENING, FAN CONNECTION BOX CONDUIT JUNCTION BOX 5 CURRENT TRANSFORMER LEAD JUNCTION BOX 6 CHANNEL BASE, SEE BASE DETAIL 7 H0 / OVERALL DEPTH 0,00,70,550 0,0 H 5 H DE-ENERGIZED TAP CHANGER WARNING NAMEPLATE TAP CHANGER MECHANISM FOR HV WINDING FOR DE-ENERGIZED OPERATION Ø.00" NPT MALE CONNECTION FOR VACUUM FILLING, WELDED NIPPLE WITH CAP 0 LIFTING LUG FOR LIFTING COMPLETE UNIT JACKING LUG WITH LIFING EYE FOR PULLING IN ALL DIRECTIONS FULLY RADIATOR GROUP BRACING, DWG #A-66 RADIATOR SHUT-OFF VALVE REMOVABLE RADIATOR, TRANTECH, MOUNTED ON SHUT-OFF VALVE, GALVANIZED 5 GROUND PAD, () 0.5-NC,.75" CENTER TO CENTER 6 GFI RECEPTACLE 7 Ø0.5" NPT FEMALE TEST CONNECTION WITH PLUG, GAS SPACE BOX MAIN CONTROL CABINET 60H X 6W X 6D WITH OPENING IN BOTTOM FOR 9 DELTAIR NITROGEN SYSTEM GAS CABINET ( FOR MAIN TANK, FOR LTC) 0 PREVENTIVE AUTO COMPARTMENT DRAIN CONNECTION - " GLOBE VALVE, UNITED # 5TSSB- (WITH /" SAMPLER) UPPER FILTER PRESS CONNECTION - " GLOBE VALVE, UNITED # 5T PRESSURE RELIEF DEVICE WITH SEMAPHORE, QUALITROL, #LPRD TRANSFORMER OIL LEVEL INDICATOR, WITH LOW LEVEL ALARM CONTACTS, 5 6 SUDDEN PRESSURE RELAY, QUALITROL # (IN AIR) 7 COOLING FAN, KRENZ, #F6X-A7-0, 0-0V, PHASE, 0 RPM, / HP, ONLY, PADLOCKING IN ANY POSITION (ALPHABETIC DESIGNATIONS) ASSEMBLED AND OIL-FILLED R5 CC DOOR SWING / SHIPPING DEPTH 06, X0 7 X X X 6 USERS CONDUIT, PROVISIONS FOR PADLOCKING (NEMA R) / INCLUDES,700 LBS FOR PREVENTIVE AUTO H 7 ON RAISED FLANGES 0 / 5 TOTAL LV BUSHING, ABB,.5-UN-A (SILVER PLATED THREAD), #05W0AT, 5 KV, PREVENTIVE AUTO,50 TOTAL (GAL.) STAINLESS STEEL NAMEPLATE, IN BOX ON TANK COVER), FOR MAIN TANK, FOR APPROXIMATE WEIGHTS (POUNDS) (@5 C) LTC (GAL.) H0 BUSHING, ABB,.5-UN-A (SILVER PLATED THREAD), #069Z0AN, 69 KV, 00/00 A, BOTTOM CONNECTED /00 A, BOTTOM CONNECTED SHIPPING WEIGHT WITHOUT OIL = 7,000 LBS RADIATORS (GAL.) 0 SHIPPING CENTER OF GRAVITY OIL HV BUSHING, ABB,.5-UN-A (SILVER PLATED THREAD), #069Z0AN, 69 KV, 00/00 A, DRAW LEAD OPERATING CENTER OF GRAVITY MAIN TANK (GAL.) 9 / 5 TANK & FITTINGS 00/00 A, DRAW LEAD 95 / OVERALL & SHIPPING WIDTH UNTANKING (CORE & COIL) PARTS LIST DESCRIPTION ITEM QTY SHIPPING VIEW HEX BOLT FLAT WASHER 7 FLANGE OF BUSHING 5 QUALITROL #0-0-0 CS-7 BUSHING INTERNAL TOOTH MOUNTING STAR WASHER FLANGE (ONLY ONE REQUIRED 6 OIL) HEX NUT ) DETAIL A. A TYPICAL MOUNTING OF BUSHING TO FLANGE R6 / LTC DOOR SWING TOP VIEW 5 / / 5 / / H H0 R5 TO STRIKE 5 5 X0 55 H H X X R6 / TO STRIKE 0 57 X R6 TO GRD S- S- 7 5 / 9 9 LTC POSITION INDICATOR LTC Ø.00" VACUUM CONNECTION, WELDED NIPPLE WITH CAP LTC Ø.00" FLANGE MOUNTED DRAIN VALVE, UNITED #7TSSB LTC MOTOR DRIVE HOUSING 5 LTC LIQUID LEVEL GAUGE 6 VACUUM EQUALIZATION PIPING (MAIN TANK TO LTC) 7 SEALED WELL BULB FOR LIQUID TEMPERATURE INDICATOR SEALED WELL BULB FOR WINDING TEMPERATURE INDICATOR 9 Ø0.5" BALL VALVE WITH PLUG FOR GAS SAMPLING, UNITED #0-/ 50 Ø0.5" BALL VALVE WITH PLUG FOR GAS SHUT-OFF, UNITED #0-/ 5 LIQUID TEMPERATURE INDICATOR, MESSKO, # WINDING TEMPERATURE INDICATOR, MESSKO, # /0 BARE COPPER CABLE (GROUNDING FOR CONTROL CABINET, LTC MOTOR DRIVE, S- FB 5 5 HV ARRESTER, ABB, #Q05NA0A, 5kV, kv MCOV 55 LV ARRESTER, ABB, #Q00NA00A, 0kV, kv MCOV 56 HV BUSHING CONNECTOR, NEMA HOLE PAD, SEFCOR #SNFT--B 57 LV BUSHING CONNECTOR, NEMA HOLE PAD, SEFCOR #SNFT--B 5 X0 BUSHING CONNECTOR, NEMA HOLE PAD, SEFCOR #SNFT90--B 59 MAIN UNIT CORE GROUND NAMEPLATE 60 PREVENTIVE AUTO CORE GROUND NAMEPLATE 6 SEALED WELL FOR FUTURE TOP OIL RTD 6 SEALED WELL FOR FUTURE HV WINDING TEMPERATURE RTD 6 SEALED WELL FOR FUTURE LV WINDING TEMPERATURE RTD 6 SEALED WELL FOR FUTURE TV WINDING TEMPERATURE RTD 65 Ø.50" OIL SAMPLING VALVES FOR FUTURE DGA MONITORING, UNITED #5T--/ 66 TV IDENTIFICATION NAMEPLATE MCM BARE COPPER CABLE, LV BUSHING TO ARRESTER CONNECTION 6 LTC LIQUID TEMPERATURE INDICATOR, SUPPLIED WITH LTC 6 6 TYP. 70 SEGMENT 5 / / 6 SEGMENT TYP TYP S- 5 / LTC HANDCRANK BOSS LOCATED INSIDE MOTOR DRIVE COMPARTMENT / 5 / 5 / 6 OVER HV ARRESTER BRACKET / OVER LV ARRESTER BRACKET 0 UNTANKING HEIGHT 9 / OVER LV/X0 BUSHING & SHIPPING HEIGHT 50 5 OVER LV ARRESTER OVER TANK FLANGE / OVER HV BUSHING CONNECTOR & OVERALL HEIGHT 0 59 OVER HV ARRESTER TO ARRESTER CONNECTIONS) 55 LTC MECHANISM COMPARTMENT, REINHAUSEN, TYPE RMVII-000 5kV, WITH NITROGEN CABINETS, LV ARRESTERS, HV ARRESTERS, X0 BUSHING, HV BUSHING PROVISIONS FOR MOUNTING UNI-HOIST (FOR SAFETY HARNESS ATTACHMENT) R TO GRD R TO GRD X 7 5 H 67 X0 H 9 VENDOR-SUPPLIED MESSKO PRESSURE RELIEF DEVICE 9 / 5 / TYP. PER BUSHING SUDDEN PRESSURE RELAY, QUALITROL # , WITH SHUTOFF VALVE (IN BASE DETAIL - BOTTOM VIEW / 70 SEGMENT

19

20

21

22

23 LR AM RL

24 NOTES:. ITEMS REMOVED FOR SHIPMENT. TANK DESIGNED FOR FULL VACUUM. MANUFACTURED IN ACCORDANCE WITH ANSI & NEMA. PAINT FINISH: ANSI #70 SKY GRAY EXTERIOR, WHITE INTERIOR 5. ALL DIMENSIONS IN INCHES 6. DESIGNED FOR -0 C 7. UNIT DESIGNED FOR RAIL SHIPMENT. MATCH-MARKED RADIATORS FOR PROPER REINSTALLATION 9. () EA SPARE HV, LV BUSHINGS 0. () SET SPARE GASKETS REQUIRED. UNDERCOAT BASE. UNIT TO BE FILLED WITH FR OIL 0 / 0 5 X0 BUSHING, ABB,.5-UN-A (SILVER PLATED THREAD), #05W0AT, 5 KV, CORE GROUND BUSHING, CENTRAL MALONEY #7055 (WITH GROUND PAD & 6 DOMED NON-SKID COVER, WELDED 7 LIFTING LOOP FOR LIFTING COVER ONLY LV SURGE ARRESTER MOUNTING 9 HV SURGE ARRESTER MOUNTING 0 DELTA STAR LOGO MAIN TRANSFORMER NAMEPLATE (STAINLESS STEEL) BOLTED MANHOLE COVER WITH FLUSH LIFTING HANDLES, Ø" ROUND OPENING, FAN CONNECTION BOX CONDUIT JUNCTION BOX 5 CURRENT TRANSFORMER LEAD JUNCTION BOX 6 CHANNEL BASE, SEE BASE DETAIL 7 H0 / OVERALL DEPTH 0,00,70,550 0,0 H 5 H DE-ENERGIZED TAP CHANGER WARNING NAMEPLATE TAP CHANGER MECHANISM FOR HV WINDING FOR DE-ENERGIZED OPERATION Ø.00" NPT MALE CONNECTION FOR VACUUM FILLING, WELDED NIPPLE WITH CAP 0 LIFTING LUG FOR LIFTING COMPLETE UNIT JACKING LUG WITH LIFING EYE FOR PULLING IN ALL DIRECTIONS FULLY RADIATOR GROUP BRACING, DWG #A-66 RADIATOR SHUT-OFF VALVE REMOVABLE RADIATOR, TRANTECH, MOUNTED ON SHUT-OFF VALVE, GALVANIZED 5 GROUND PAD, () 0.5-NC,.75" CENTER TO CENTER 6 GFI RECEPTACLE 7 Ø0.5" NPT FEMALE TEST CONNECTION WITH PLUG, GAS SPACE BOX MAIN CONTROL CABINET 60H X 6W X 6D WITH OPENING IN BOTTOM FOR 9 DELTAIR NITROGEN SYSTEM GAS CABINET ( FOR MAIN TANK, FOR LTC) 0 PREVENTIVE AUTO COMPARTMENT DRAIN CONNECTION - " GLOBE VALVE, UNITED # 5TSSB- (WITH /" SAMPLER) UPPER FILTER PRESS CONNECTION - " GLOBE VALVE, UNITED # 5T PRESSURE RELIEF DEVICE WITH SEMAPHORE, QUALITROL, #LPRD TRANSFORMER OIL LEVEL INDICATOR, WITH LOW LEVEL ALARM CONTACTS, 5 6 SUDDEN PRESSURE RELAY, QUALITROL # (IN AIR) 7 COOLING FAN, KRENZ, #F6X-A7-0, 0-0V, PHASE, 0 RPM, / HP, ONLY, PADLOCKING IN ANY POSITION (ALPHABETIC DESIGNATIONS) ASSEMBLED AND OIL-FILLED R5 CC DOOR SWING / SHIPPING DEPTH 06, X0 7 X X X 6 USERS CONDUIT, PROVISIONS FOR PADLOCKING (NEMA R) / INCLUDES,700 LBS FOR PREVENTIVE AUTO H 7 ON RAISED FLANGES 0 / 5 TOTAL LV BUSHING, ABB,.5-UN-A (SILVER PLATED THREAD), #05W0AT, 5 KV, PREVENTIVE AUTO,50 TOTAL (GAL.) STAINLESS STEEL NAMEPLATE, IN BOX ON TANK COVER), FOR MAIN TANK, FOR APPROXIMATE WEIGHTS (POUNDS) (@5 C) LTC (GAL.) H0 BUSHING, ABB,.5-UN-A (SILVER PLATED THREAD), #069Z0AN, 69 KV, 00/00 A, BOTTOM CONNECTED /00 A, BOTTOM CONNECTED SHIPPING WEIGHT WITHOUT OIL = 7,000 LBS RADIATORS (GAL.) 0 SHIPPING CENTER OF GRAVITY OIL HV BUSHING, ABB,.5-UN-A (SILVER PLATED THREAD), #069Z0AN, 69 KV, 00/00 A, DRAW LEAD OPERATING CENTER OF GRAVITY MAIN TANK (GAL.) 9 / 5 TANK & FITTINGS 00/00 A, DRAW LEAD 95 / OVERALL & SHIPPING WIDTH UNTANKING (CORE & COIL) PARTS LIST DESCRIPTION ITEM QTY SHIPPING VIEW HEX BOLT FLAT WASHER 7 FLANGE OF BUSHING 5 QUALITROL #0-0-0 CS-7 BUSHING INTERNAL TOOTH MOUNTING STAR WASHER FLANGE (ONLY ONE REQUIRED 6 OIL) HEX NUT ) DETAIL A. A TYPICAL MOUNTING OF BUSHING TO FLANGE R6 / LTC DOOR SWING TOP VIEW 5 / / 5 / / H H0 R5 TO STRIKE 5 5 X0 55 H H X X R6 / TO STRIKE 0 57 X R6 TO GRD S- S- 7 5 / 9 9 LTC POSITION INDICATOR LTC Ø.00" VACUUM CONNECTION, WELDED NIPPLE WITH CAP LTC Ø.00" FLANGE MOUNTED DRAIN VALVE, UNITED #7TSSB LTC MOTOR DRIVE HOUSING 5 LTC LIQUID LEVEL GAUGE 6 VACUUM EQUALIZATION PIPING (MAIN TANK TO LTC) 7 SEALED WELL BULB FOR LIQUID TEMPERATURE INDICATOR SEALED WELL BULB FOR WINDING TEMPERATURE INDICATOR 9 Ø0.5" BALL VALVE WITH PLUG FOR GAS SAMPLING, UNITED #0-/ 50 Ø0.5" BALL VALVE WITH PLUG FOR GAS SHUT-OFF, UNITED #0-/ 5 LIQUID TEMPERATURE INDICATOR, MESSKO, # WINDING TEMPERATURE INDICATOR, MESSKO, # /0 BARE COPPER CABLE (GROUNDING FOR CONTROL CABINET, LTC MOTOR DRIVE, S- FB 5 5 HV ARRESTER, ABB, #Q05NA0A, 5kV, kv MCOV 55 LV ARRESTER, ABB, #Q00NA00A, 0kV, kv MCOV 56 HV BUSHING CONNECTOR, NEMA HOLE PAD, SEFCOR #SNFT--B 57 LV BUSHING CONNECTOR, NEMA HOLE PAD, SEFCOR #SNFT--B 5 X0 BUSHING CONNECTOR, NEMA HOLE PAD, SEFCOR #SNFT90--B 59 MAIN UNIT CORE GROUND NAMEPLATE 60 PREVENTIVE AUTO CORE GROUND NAMEPLATE 6 SEALED WELL FOR FUTURE TOP OIL RTD 6 SEALED WELL FOR FUTURE HV WINDING TEMPERATURE RTD 6 SEALED WELL FOR FUTURE LV WINDING TEMPERATURE RTD 6 SEALED WELL FOR FUTURE TV WINDING TEMPERATURE RTD 65 Ø.50" OIL SAMPLING VALVES FOR FUTURE DGA MONITORING, UNITED #5T--/ 66 TV IDENTIFICATION NAMEPLATE MCM BARE COPPER CABLE, LV BUSHING TO ARRESTER CONNECTION 6 LTC LIQUID TEMPERATURE INDICATOR, SUPPLIED WITH LTC 6 6 TYP. 70 SEGMENT 5 / / 6 SEGMENT TYP TYP S- 5 / LTC HANDCRANK BOSS LOCATED INSIDE MOTOR DRIVE COMPARTMENT / 5 / 5 / 6 OVER HV ARRESTER BRACKET / OVER LV ARRESTER BRACKET 0 UNTANKING HEIGHT 9 / OVER LV/X0 BUSHING & SHIPPING HEIGHT 50 5 OVER LV ARRESTER OVER TANK FLANGE / OVER HV BUSHING CONNECTOR & OVERALL HEIGHT 0 59 OVER HV ARRESTER TO ARRESTER CONNECTIONS) 55 LTC MECHANISM COMPARTMENT, REINHAUSEN, TYPE RMVII-000 5kV, WITH NITROGEN CABINETS, LV ARRESTERS, HV ARRESTERS, X0 BUSHING, HV BUSHING PROVISIONS FOR MOUNTING UNI-HOIST (FOR SAFETY HARNESS ATTACHMENT) R TO GRD R TO GRD X 7 5 H 67 X0 H 9 VENDOR-SUPPLIED MESSKO PRESSURE RELIEF DEVICE 9 / 5 / TYP. PER BUSHING SUDDEN PRESSURE RELAY, QUALITROL # , WITH SHUTOFF VALVE (IN BASE DETAIL - BOTTOM VIEW / 70 SEGMENT

25

26

27

28

29 LR AM RL

30

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration 1TSF14000167/CD LINE ITEM 1: 37,5 KVA 1 PHASE PAD MOUNTED TRANSFORMER, ENVIROTEMP FR3 37.5 KVA, 10 Pad Mounted Transformer, AIMS! TYPE 2 SHRUBLINE insulating fluid 12470 Deita Two position ioadbreak switch

More information

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17 GENERAL INFORMATION SECTION GUIDE SECTION 10 PAGE 1 DESCRIPTION SECTION NUMBER GENERAL INFORMATION... 10 POLE MOUNT TRANSFORMER SINGLE PHASE... 15 PAD MOUNT TRANSFORMER SINGLE PHASE..... 16 POLE MOUNT

More information

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer This document contains sample specifications for Liquid-Filled Type Drive Transformers You may

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ

SUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ QUALITROL TRANSFORMER BY VANTRAN 10 VAC PSIG 0 5 5 QUALITROL 10 PRESS PSIG 0 40 60 80 20 100 QUALITROL 120 25c SUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ 115"

More information

C. System Design and Performance Requirements

C. System Design and Performance Requirements Change History Date Description of Change Pages / Sections Modified 6/15/16 Updated division section from 16361-E-E to 26 10 03, removed references to other section numbers A. Summary - mgl44 Change Approver

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

SECTION PADMOUNT TRANSFORMER - OIL FILLED

SECTION PADMOUNT TRANSFORMER - OIL FILLED SECTION 26 12 19.01 PADMOUNT TRANSFORMER - OIL FILLED PART 1 GENERAL 1.1 DESCRIPTION: Padmount Transformers and Insulating Oil with underground primary and secondary connections for use in distribution

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit Substation Transformers Primary or Secondary Unit GENERAL Cooper Power Systems Primary or Secondary Unit Substation Transformers are designed to meet exact customer specifications. Flexibility in design,

More information

Transformer Components & Accessories

Transformer Components & Accessories Transformer Components & Accessories Brian Brinson Mechanical Design Manager brian.brinson@spx.com Agenda 1. Standards / Equipment Overview 2. Bushings 3. Arresters 4. Cooling Equipment 5. Instrument Transformers

More information

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled 1500 kva Pad Mount Transformer - 24940GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled Part #: MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R Page: 1 The MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018 CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS September 2018 Myrick Clinton Cannon TN P.E. #112337 Patterson & Dewar Engineers, Inc. P. O. Box

More information

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open Substation Transformers Primary or Secondary Open GENERAL Cooper Power Systems Primary or Secondary Open Substation Transformers are designed to meet exact customer specifications. Flexibility in design,

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1 WeSTinghouse Descriptive Bulletin 47-156 Page 1 liquid Filled, Self-Contained 112% 2500 Kva June, 1974 Supersedes DB 47-350, dated August 1972 E, D, C/2082/DB Descriptive Bulletin 47-156 Page 2 Westinghouse

More information

Standard Features and Accessories

Standard Features and Accessories 14.0-12 Secondary Unit Substations Secondary Below 1000V Product Overview General Description December 2012 Sheet 14012 Liquid-Filled Substation Transformers Application Description Eaton s liquid-filled

More information

Single-Phase Step Voltage Regulators

Single-Phase Step Voltage Regulators Voltage Regulators Catalog Data CA225001EN Supersedes March 2017 COOPER POWER SERIES Single-Phase Step Voltage Regulators Contents GENERAL....2 STANDARD FEATURES....4 OPTIONAL ACCESSORIES...4 ARRESTERS....4

More information

Underground Distribution Switchgear

Underground Distribution Switchgear Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,

More information

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled 500 kva Pad Mount Transformer - 12470V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled Part #: MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU Page: 1 The MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU

More information

Switchgear Skid, C1192

Switchgear Skid, C1192 CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts

More information

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed. City of Cartersville Electric System P.O. Box 1390 320 S. Erwin St. Cartersville, GA 30120 770-387-5631 March 2006 SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS This specification provides standardization

More information

www. ElectricalPartManuals. com Westinghouse Type RSL Rectangular Coil Core Form Liquid Immersed Substation Transformers

www. ElectricalPartManuals. com Westinghouse Type RSL Rectangular Coil Core Form Liquid Immersed Substation Transformers Westinghouse Application Type RSL transformers are designed in accordance with USA standard C57.12.10 and NEMA publication No. TR-11-1967 to meet the need for an economical and reliable line of substation

More information

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES Voltage Regulators Single-Phase Pad-mounted Step GENERAL McGraw-Edison Single-Phase Padmounted Voltage Regulators add a dimension to underground system planning. They provide system planners freedom to

More information

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

Single-phase step voltage regulators

Single-phase step voltage regulators Voltage Regulators Catalog Data CA225001EN Supersedes 225-10 February 2014 COOPER POWER SERIES General Eaton's Cooper Power series VR-32 singlephase step voltage regulators are tap-changing autotransformers.

More information

ABB Transformadores para aplicaciones solares y eolicas

ABB Transformadores para aplicaciones solares y eolicas ABB Transformadores para aplicaciones solares y eolicas Product offering overview - Jeff City 1Ø and 3Ø pad-mounted transformers 10-250 kva 45-3000 kva ABB Group abril 9, 2016 Slide 2 Product offering

More information

Volt Instrument Transformers

Volt Instrument Transformers www. kuhlman. com Kuhlman Electric Corporation Instrument Transformers 1 Table of Contents Description Model Page Wound, Oil-Filled VT (High Accuracy available) UTE-145-OH 3-4 Wound, Oil-Filled CCVT (High

More information

ABB Ltd. FACTORY IN HANOI

ABB Ltd. FACTORY IN HANOI ABB LTD. ABB Ltd. was originally a JVC between the Vietnamese Transformers Manufacture CTBT and the International Electromechanical group ABB Company was established 1st Sep. 1994 Distribution Transformers

More information

Substation Transformers

Substation Transformers Substation Transformers PEAK Substation Transformers Electrical Apparatus 210-90 GENERAL Cooper Power Systems PEAK Substation Transformers are a class of transformer technologies that are designed to improve

More information

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation MOBILE SUBSTATIONS Energy Solution INTERNATIONAL FAIR MOBILE SUBSTATIONS ENERGY SOLUTION Complete design for energy s generations, transmission and distribution Mobile Substations Applications of Inesing

More information

Unit Substation Transformers 5 and 15 KV Class

Unit Substation Transformers 5 and 15 KV Class Transformers 5 and 15 KV Class 85 General Information Description Federal Pacific unit substation transformers are available in a wide variety of types and ratings to provide reliable and versatile electrical

More information

Single-Phase Step Voltage Regulator

Single-Phase Step Voltage Regulator Single-Phase Step Voltage Regulator - Overhead Mounted - Page 1 of 12 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3 3 RIV REQUIREMENT... 7 4 REGULATOR CONTROLS... 7 5 TESTS... 9 6 EVALUATION...

More information

Submersible Vacuum Fault Interrupters

Submersible Vacuum Fault Interrupters Submersible Vacuum Fault Interrupters UG Distribution Medium Voltage Vacuum Fault Interrupters Functional Specification Guide PS024002EN Functional Specification for 2.4kV to 17.5kV UG Distribution Medium

More information

NEW Solutions for Underground System Growth

NEW Solutions for Underground System Growth NEW Solutions for Underground System Growth Cooper s Single-Phase Voltage Regulator Improved Power Quality More Economical Improved System Reliability Increased Safety Better Aesthetics Lower Maintenance

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High

More information

100 / 110 DRYWELL FUSE SPECIFICATION

100 / 110 DRYWELL FUSE SPECIFICATION 100 / 110 DRYWELL FUSE SPECIFICATION 15KV & 25KV SUBMERSIBLE VACUUM LOAD INTERRUPTERS AND DRYWELL FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED SUBMERSIBLE SWITCHGEAR WITH LOAD INTERRUPTING SWITCHES

More information

Distribution Transformers

Distribution Transformers Distribution Transformers PEAK Three-Phase Pad-mounted Compartmental Type Functional Specification Guide Functional Specification for Three-Phase Pad-Mounted PEAK Distribution Transformers 45 10,000 kva

More information

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED SWITCHGEAR WITH VACUUM LOAD

More information

Technical Specification for Pole Mounted Capacitor Rack

Technical Specification for Pole Mounted Capacitor Rack Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER Solid Dielectric Load Break Switch SPECIFICATION 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED VACUUM LOAD INTERRUPTING

More information

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings Page 1 Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings I. General This specification covers the design requirements for a pad-mounted capacitor

More information

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR RED JACKET Extracta Remote Gasoline Pumps Models P75S17-3, P150S17-3 & X4P150S17 380 Volt, 3 Phase, 50 Hertz by 051-138 Rev. C ELECTRICAL SERVICE

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

Single-Phase Ventilated

Single-Phase Ventilated Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Three-Phase Ventilated

Three-Phase Ventilated Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Proudly Made In America

Proudly Made In America Proudly Made In America VanTran Introduction VanTran Industries, Inc. is a manufacturer of liquid-filled transformers for the industrial, commercial, solar, and utility markets. We are known for engineering

More information

Issued Revised Approved Reviewed October 31, 1984 October 22, 2002 J. Ross J. Fuller

Issued Revised Approved Reviewed October 31, 1984 October 22, 2002 J. Ross J. Fuller Number: 5344-1.1.311 Rev. 8 Portable Mine Power Centres Issued Revised Approved Reviewed October 31, 1984 October 22, 2002 J. Ross J. Fuller SCOPE This specification covers general material and design

More information

MEDIUM POWER TRANSFORMER

MEDIUM POWER TRANSFORMER MEDIUM POWER TRANSFORMER MEDIUM POWER TRANSFORMER FROM 3,15 TO 31,5 MVA HIGHEST VOLTAGE FOR MATERIAL 72,5kV GENERAL CHARACTERISTICS Three phase oil-immersed naturally cooled type ONAN medium power transformers.

More information

COOPER POWER SERIES. VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions

COOPER POWER SERIES. VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions Voltage Regulators MN225008EN Effective February 2017 Supersedes May 2015 COOPER POWER SERIES VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions DISCLAIMER

More information

S Voltage Regulators. Contents. VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions

S Voltage Regulators. Contents. VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions Voltage Regulators VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions Service Information S225-10-30 Figure 1. VR-32 Voltage Regulator with Quik-Drive

More information

CABINET OPTIONS AND DESIGNATORS CODE LETTERS

CABINET OPTIONS AND DESIGNATORS CODE LETTERS CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Stackable Crescent Cuber Models A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71332 Issued: 7-7-2011 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

H20.5 Series Electric Fryers

H20.5 Series Electric Fryers Component Box Assembly and Associated Hardware, Thermostats and Related Components and Controller Component Box Assembly and Associated Hardware, Thermostats and Related Components and Contro FRY_P_0002_12_14_Component

More information

QGD-20/25/30 & QGD-40/50

QGD-20/25/30 & QGD-40/50 QGD-0/5/0 & QGD-40/50 Direct Drive Rotary Screw Air Compressor Parts Manual This manual contains important safety information and should be made available to all personnel who operate and/or maintain this

More information

distribution transformers. Single-Phase Overhead GENERAL. Cooper Power Systems manufactures a complete line of single-phase overhead-type

distribution transformers. Single-Phase Overhead GENERAL. Cooper Power Systems manufactures a complete line of single-phase overhead-type Distribution Transformers Single-Phase Overhead Electrical pparatus 0-0 GENERL ooper Power Systems manufactures a complete line of single-phase overhead-type distribution transformers. Single-phase transformers

More information

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33 SECTION V INDEX Product Description Page Number Junction Boxes......................................V-V2 Meter and Instrument Enclosures.......................V24-V Control Centers.....................................V4-V9

More information

Underground Distribution Switchgear

Underground Distribution Switchgear Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,

More information

Product Specifications for Phase Over Phase GOABS(r)

Product Specifications for Phase Over Phase GOABS(r) 1. General a) This specification covers the design, manufacture, and shipment of phase-over-phase, 1-way, 2-way, 3-way, and 4-way, gang-operated disconnecting switches, both air-break and load-break, for

More information

Accessories and spare parts

Accessories and spare parts Accessories and spare parts ACCESSORIES AND SPARE PARTS FOR SOLENOID VALVES G9150/R06 9150/R07 9150/R08 9150/R09 9150/R10 9151/R04 9150/R50 9150/R11 9150/R43 008217 008218 008229 200193 009060 200646 004259

More information

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor 35-kV Safefront 2 Amp SuperWell 5-33 Page 1 216 EPM-PMS-35-311P-R2/ESW Three Phase Two Ways per Phase 2 Amp 35 kv Class Eaton's CPS LRTPs NEMA Standard Outdoor Instrument Transformer Provisions 21.1/36.6

More information

Product Specifications for Aluminum Vertical Break Switches

Product Specifications for Aluminum Vertical Break Switches 1. General a) This specification covers the design, manufacture, and shipment of aluminum vertical break switches, both air-break and load-break configurations, for substation and transmission switching

More information

Padmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage

Padmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage Padmount Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage ABB s Padmounted Transformers provide tamper-resistant protection in

More information

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026 TECHNICAL PERTICULAR FOR 1.6 MVA 6.6/0.433 KV SERVICE TRANSFORMER 1.00.00 GENERAL 1.01.00 Service SERVICE 1.02.00 Make ASHOK/VOLTAMP/DANKE/CGL 1.03.00 Type CORE 1.04.00 Location OUTDOOR 1.05.00 Specification

More information

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec **** Page 1 of 8 ****Supercedes BECo Standard E2.12-2.12 and ComElectric Spec 6-0895**** 1.0 General Requirements SINGLE PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMERS 1.1 These specifications cover single-phase

More information

Distribution transformers Efficiency over life-cycle

Distribution transformers Efficiency over life-cycle Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

Lincolnweld AC-1000 POWER SOURCE

Lincolnweld AC-1000 POWER SOURCE P-73-A RETURN TO MAIN INDEX P-73-A Lincolnweld AC-1000 POWER SOURCE Model Index NUMBERS IN THE TABLE BELOW INDICATE WHICH COLUMN TO USE IN EACH PARTS LIST FOR EACH INDIVIDUAL CODE NUMBER PARTS LIST TITLES

More information

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

DIAMOND P R O D U C T S

DIAMOND P R O D U C T S DIAMOND P R O D U C T S Parts List Manual Hydra-Gen 123 HP Power Unit with Electric Controls Part #: CC-HG-SK (January 2008) Part#: 1805052 Table of Contents Hydraulic Pump and Manifold 4 Hydraulic Tank

More information

INSTRUCTION MANUAL #103

INSTRUCTION MANUAL #103 INSTRUCTION MANUAL #103 www.ermco eci.com THREE PHASE PAD MOUNT DISTRIBUTION TRANSFORMER General instruc ons for installa on and opera on of Three Phase Pad Mount Distribu on Transformer. 2 INTRODUCTION

More information

D503K 5+3HO & D500K 5+3

D503K 5+3HO & D500K 5+3 P-378 P-378 PARTS LIST FOR D503K HO & D500K P-378-A.1 P-378-A.1 D503K & D500K For Code: 10748, 10569 & C1260710137 Do Not use this Parts List for a machine if its code number is not listed. Contact the

More information

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115 CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115 PADMOUNTED TRANSFORMERS 12kV AND DUAL VOLTAGE, RADIAL FEED STAINLESS STEEL NOVEMBER 2011 Specification:ELE_115_R1 Page

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 34500 Volt Instrument Transformers 34500 Volt Table of Contents Description Model Page Wound, Dry-Type VT Y (High Accuracy available) PTT-200-9710(H) 3-4 Wound, Oil-Filled

More information

Sludge Dewatering and Odor Control at Plant 1 CONFORMED

Sludge Dewatering and Odor Control at Plant 1 CONFORMED 2. Fire Service Main Interior Piping from Exterior Service up to Fire Sprinkler Alarm Check Valve: a. Pipe: Schedule 40 galvanized steel. b. Fittings: Galvanized 150-pound malleable iron, screwed or Victaulic

More information

Distribution Transformers

Distribution Transformers Distribution Transformers Three-Phase Pad-Mounted Compartmental Type Functional Specification Guide Functional Specification for Three-Phase Pad-Mounted Distribution Transformers 45 10,000 kva 1.0 Scope

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 59 Model DDX Deluge Valve (50 mm), ½ (65 mm), (80 mm), 76 mm, 4 (00 mm), 6 (50 mm), 65 mm & 8 (00 mm) Bulletin 59 Instructions for Installation, Operation, Care and Maintenance Wet Pilot Line,

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,

More information

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#: Single phase pole mounted Distribution Transformers 11kV Prepared by: ARY SAIDAHMED SHEKSAEED Electrical Engineer KEU ID#: 4252 Email: ary.sayd@hotmail.com 1 S # Contents Page # 1 Introduction 3 2 Type

More information

Single-phase pad-mounted step voltage regulator

Single-phase pad-mounted step voltage regulator Voltage Regulators Catalog Data CA225002EN Supersedes February 2015 COOPER POWER SERIES Single-phase pad-mounted step voltage regulator General Eaton's Cooper Power series single-phase pad-mounted voltage

More information

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec **** Page 1 of 8 ****Supercedes BECo Standard E2.12-2.14 and ComElectric Spec 7-0895**** THREE-PHASE DEADFRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS, LOOP & RADIAL FEED DESIGNS 1.0 General Requirements 1.1

More information

Single Phase Padmounted Transformers kva

Single Phase Padmounted Transformers kva Single Phase Padmounted Transformers 10-250 kva Introduction to ABB ABB is a global leader in power and automation technologies that enable utility and industry customers to improve their performance while

More information

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008 CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008 SPECIFICATION NO: ELE_112_R1.doc Page 1 of 3 Rev. 10/28/2008 SPECIFICATION

More information

www. ElectricalPartManuals. com Westinghouse PLAZAPADTM Tamper-Resistant Transformers For Underground Power Distribution 750 Thru 2500 Kva

www. ElectricalPartManuals. com Westinghouse PLAZAPADTM Tamper-Resistant Transformers For Underground Power Distribution 750 Thru 2500 Kva Westinghouse Descriptive Bulletin 47-256 Page 1 PLAZAPADTM Tamper-Resistant Transformers For Underground Power Distribution 3-Phas8, Liquid-Immersed 750 Thru 2500 Kva Application The Westinghouse Plazapad

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide 1ZUA2761-500 rev. 5, 6 April 2010 High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide 1ZUA2761-500 rev. 5, 6 April 2010 2 / 9 Table of contents 1 Description... 3 2 Ratings...

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

Master Series. Gas XPress Grill. Parts List. Models, Non-CE & CE Versions: XG24 XG36

Master Series. Gas XPress Grill. Parts List. Models, Non-CE & CE Versions: XG24 XG36 Master Series Gas XPress Grill Parts List Models, Non-CE & CE Versions: XG24 XG36 Document Number: G_GHD_PL_XPRESS_XG24ANDXG36 (rev 3 updated: /6) Cooking Zone Designation The Xpress Grill is a cooking

More information

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana Supersedes Descriptive Bulletin, pages 1-8, dated January, 1976 Mailed to: E, D, C/38-000F Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

More information

Trane Liqui-Flo Addendum. Instruction Manual D2-3415

Trane Liqui-Flo Addendum. Instruction Manual D2-3415 Trane Liqui-Flo Addendum Instruction Manual D2-3415 The information in this manual is subject to change without notice. Throughout this manual, the following notes are used to alert you to safety considerations:!

More information

REPLACEMENT PARTS MANUAL HEAT KING HK300. Mobile Glycol Heating System

REPLACEMENT PARTS MANUAL HEAT KING HK300. Mobile Glycol Heating System REPLACEMENT PARTS MANUAL HEAT KING HK300 Mobile Glycol Heating System Disclaimer This manual is proprietary to Heat King Division of Tamarack Industries (hereafter Heat King ), and may be revised from

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

DISTRIBUTION TRANSFORMERS SPECIFICATION #

DISTRIBUTION TRANSFORMERS SPECIFICATION # DISTRIBUTION TRANSFORMERS SPECIFICATION #1212.01 12.47kV Grd Wye Padmount & Polemount Bid No. 16-93 Exhibit I Page 1 of 19 TABLE OF CONTENTS 1 SCOPE... 3 2 STANDARDS... 3 3 EVALUATION AND AWARD... 3 4

More information

C15 D5 and D6 (PCC1300 and 1301) CONTENTS

C15 D5 and D6 (PCC1300 and 1301) CONTENTS CONTENTS 0100-3920 Engine Accessories (Denso... 5 Radiator) 0100-4025 Engine Accessories (SRF Radiator)... 7 0179-3766 Battery Charger Instl... 9 0179-3771 Miniature Circuit Breaker Instl... 11 0179-3772

More information